2.26 S OLENOID VALVES S ERIES VQ1000

Size: px
Start display at page:

Download "2.26 S OLENOID VALVES S ERIES VQ1000"

Transcription

1 2.26 S OLENOID VALVES 5 PORT M ETAL S EAL/RUBBER S EAL U LTRA H IGH S PEED S OLENOID VALVE High Speed Response from new Solenoid Design. Long Life: Over 200 Million Cycles can be with Patent Pilot Valve design. Indicator light and Voltage Surge Suppressor Space Saving Design Five Options for Manifold Electrical Connection. Plug lead and Plug In valve manifold options. New cassette type manifold available. T ECHNICAL SPECIFICATIONS Type of Seal Metal Rubber Fluid Air, inert gas Air, inert gas Min Operating Pressure Single 0.MPa/4.5PSI 0.5MPa/22PSI Double 0.MPa/4.5PSI 0.MPa/4.5PSI 3-position 0.MPa/4.5PSI 0.2MPa/29PSI Max Operating Pressure (Note.) 0.75MPa/09PSI 0.75MPa/09PSI Effective Area Single 3.6 (0.2) 5.4 (0.3) (Cv Factor) mm 2 Double 3.6 (0.2) 5.4 ( position 3.6 (0.2) 5.4 (0.3) Response Time Single Max 2ms Max 5ms (Note 2). Double Max 0ms Max 5ms 3-position Max 20ms Max 25ms Life 200 million cycles or more Ambient and Fluid Temperature (Note 3) -0 to +50ºC (4~22ºF) -5 to +50ºC (23~22ºF) Lubricant (Note 4) Not required Not required Manual Override Non-locking, Push Non-locking, Push Protection Dustproof Dustproof (Note ) (Note 2) (Note 3) (Note 4) Contact SMC Customer Service for 45PSI (0 Bar). Calculated on the basis of JIS B (Supply pressure 0.5 MPa {5. bar}; the above valve shows reponse time checked when the valve is equipped with an indicator light and surge voltage suppressor). Use dry air to prevent dew condensation in the case when temperature is low. Perfect dry air (dew point equals to -30ºC) No grease on main valve. Special types (Contact SMC Customer Service for details and availability): i Pressure centre function ii External pilot iii Low power consumption (0.5W) iv Positive common wiring S OLENOID SPECIFICATIONS Coil Rated Voltage 2 VDC, 24 VDC 00/0 VAC Allowable Voltage + - 0% of Rated Voltage + - 0% of Rated Voltage Type of Coil Insulation Class B Class B Power Consumption (Note ) W Inrush/Holding:. VA (ma) Electrical Entry Plug In or Connector Type Plug In or Connector Type (Note ) Contact SMC for the low power consumption (0.5W) type. W IRING SPECIFICATIONS POSITIVE COM W IRING SPECIFICATIONS NEGATIVE COM (OPTION) S YMBOLS

2 S OLENOID VALVES 2.27 F K IT D-SUB CONNECTOR (25 PIN) The D-Sub Connector permits simple rationalization and installation labor saving for Electrical Connection. The D-Sub Connector (25-pin std., 5-pin option) conforms with MIL permitting use of commercial connectors with wide interchangeability. Top or Side Connector Receptacle Position can be selected in accordance with the available mounting space. Standard max 8 stations (Optional 6 stations possible). The total number of stations is tabulated starting from station one at the D side. P K IT (FLAT C ABLE C ONNECTION) MIL Flat Cable Connector permits simple rationalization and installation labor savings for Electrical Connection. The Connector (26 pin; 0-, 6-, and 20 pin optional) conforms with MIL spec permitting use of widely interchangeable commercial connectors. Top or Side Receptable Position can be selected in accordance with the available mounting space. Standard max 8 Stations (Optional 6 Stations optional). S EE INSIDE FRONT COVER FOR DETAILS OF YOUR LOCAL SALES OFFICE

3 2.28 S OLENOID VALVES T K IT (TERMINAL B LOCK B OARD) This Kit has a small Terminal Block inside a junction box. The Electrical Entry Port G (PF) /2 permits connection of Conduit Fittings. Max 2 Stations. B ODY P ORTED V ALVE - SINGLE U NIT VQ000 VQ C ONFIGURATION 2 Position single 2 2 Position double (latching) 3 3 Position closed centre 4 3 Position exhaust centre 5 3 Position pressure centre T YPE OF S EAL 0 Metal Rubber 6 0 N 5 L C6 S UBPLATE SUP CYLINDER P ORTS C3 One Touch Fittings for Ø3.2 C4 One Touch Fittings for Ø4 C6 One Touch Fittings for Ø6 M5 M5 (0-32Nom) N One Touch Fittings ø/8 N3 One Touch Fittings ø5/32 N7 One Touch Fittings ø/4 (Note) EXH Port is a Direct Exhaust Type (with Built In Silencer) M ANUAL O VERRIDE -.Non locking recessed type Note) B Locking tool type* *C Locking knob type Note) Locking type (B) is standard for double (latching) type. Indicate B in model no. Option P ILOT V ALVE S PECIFICATIONS (OPTION) - W Standard H.5W (High speed response) Y Low wattage type (Note) N Negative common wiring (Note): Except for 0 VAC type. E LECTRICAL E NTRY G Grommet (Except for latching type and 00/0VAC) L L type plug connector with lead wire LO L type plug connector without connector M M type plug connector with lead wire MO M type plug connector without connector C OIL R ATED V OLTAGE 3 0VAC 5 24VDC 6 2VDC

4 S OLENOID VALVES 2.29 B ASE M OUNTED T YPE P LUG I N U NIT VQ000 M A N I F O L D VV5Q 08 C6 F U N : VQ000 T YPE OF M ANIFOLD Plug In Unit - Base Mounted N UMBER O F S TATIONS 0 Station 6 6 Stations C YLINDER PORTS C3 One Touch Fittings for Ø3.2 C4 One Touch Fittings for Ø4 C6 One Touch Fittings for Ø6 M5 M5 (0-32Nom) N One Touch Fittings ø/8 N3 One Touch Fittings ø5/32 N7 One Touch Fittings ø/4 * Mixed Ports Available O PTION Symbol Option VQ000 (Blank) None B Check valve for prevention of back pressure D DIN Rail Mounted Type J With Vacuum Ejector Unit N With Nameplate R External Pilot capable S Built-in Silencer (Direct Exhaust) Note ) Note 2) Note 3) Note4) When more than one option is desired Combined symbols in alphabetical order. Example) BRS Models with a suffix -B have checked valves for prevention of back pressure at all manifold stations. In the case of the external pilot -R, order solenoid valves with the external pilot specification R. Contact SMC for details of vacuum ejector unit. Combination of ejector option J and nameplate N is not possible. Note) Note2) Insert code L (upward) or B (downward) for elbow type fittings for all manifold stations. Example) B6: Elbow one touch fittings for downward (bottom) piping. LM for models with elbow fittings and mixed cylinder port sizes. K IT ELECTRICAL ENTRY CABLE LENGTH S EE INSIDE FRONT COVER FOR DETAILS OF YOUR LOCAL SALES OFFICE

5 2.30 S OLENOID VALVES V A L V E VQ 0 0 N 5 M ANUAL O VERRIDE 0 VQ000 S YMBOLS *Option 2 Indicator light and surge voltage suppressor -.. Yes E...No 3 4 C OIL V OLTAGE 3 0VAC 5 24VDC 6 2VDC 5 T YPE OF S EAL 0 Metal Rubber P ILOT V ALVE S PECIFICATIONS - W (Standard) H.5W (High Speed response) Y Low wattage (0.5W) N Negative common (blank is positive common) ACCESSORIES MANIFOLD OPTIONS B LANKING PLATE ASSEMBLY VVQ000-0A-5 SUP BLOCK PLATE P VVQ000-6A- R PR N AMEPLATE [-N] VVQ000-N5-Station (-Max. stations) B UILT IN SILENCER Direct exhaust [-S] I NDIVIDUAL SUP SPACER VVQ000-P--C6 P LANKING PLUG 23 KQP STATIONS MATCHING FITTINGS ASSEMBLY VVQ000-52A-C8 (VQ000) INDIVIDUAL EXH SPACER VVQ000-R--C6 EXH BLOCK BASE ASSEMBLY - F - C3 VVQ000-9A- P - C4 - C6- (VQ000) L - - M5 N N3 N7 E LBOW FITTINGS ASSEMBLY C4 VVQ000-F-L- C6(VQ000) C3 M5 N N3 N7 S ILENCER (EXH PORT) V ACUUM EJECTOR UNIT VVQ000-J A BM (VQ000) C HECK VALVE FOR PREVENTION OF DIN RAIL MOUNTEDBRACKET [-D] OF BACK PRESSURE ASSEMBLY [-B] VVQ000-57A VVQ000-8A

6 S OLENOID VALVES 2.3 B ODY P ORTED T YPE P LUG L EAD U NIT/FLIP T YPE M A N I F O L D VV5Q 4 08 F S D VQ000 K IT T YPE OF M ANIFOLD 4 Plug in unit/flip type N UMBER O F S TATIONS 0 Station 6 6 Stations The number of stations differs from kit to kit. DIN RAIL/OPTION Symbol Option - None (C kit only) Note2) D DIN Rail Mounted Type N With Nameplate Note3) S Built-in Silencer (Direct Exhaust) Note ) Note 2) Note 3) When more than one option is desired Combined symbols in alphabetical order. Example) DNS All F, P, and S kits are of DIN rail mounted type.so include suffix D. F, P, and S kits are provided with an exhaust on one side while C kits are with an exhaust on both sides. K IT ELECTRICAL E NTRY C ABLE L ENGTH Note ) Note 2) The max. standard stations are 8. With single wiring arangement of up to 6 stations is possible. Specify the arrangement of stations using the manifold specification formfor more than 8 stations. Other than those above, F and P kits with different number of pins are available. S EE INSIDE FRONT COVER FOR DETAILS OF YOUR LOCAL SALES OFFICE

7 2.32 S OLENOID VALVES V A L V E VQ 4 0 Y 5 L C6 C YLINDER P ORTS C3 One Touch Fittings for Ø3.2 VQ000 C4 One Touch Fittings for Ø4 C6 One Touch Fittings for Ø6 C ONFIGURATION M5 M5 (0-32Nom) N One Touch Fittings ø/8 N3 One Touch Fittings ø5/32 N7 One Touch Fittings ø/4 2 M ANUAL O VERRIDE N OTE)3 N OTE)4 Standard model of a double (latching) type should be selected a push-locking type. Clearly write a symbol B oe C. A manual override for pilot valve is provided to the standard model for double type. N OTE)5 Note ) 3 position types need two stations Note ) F,P,T, and S kits need connector assembly when increasing the valve station. T YPE OF S EAL 0 Metal Rubber P ILOT V ALVE S PECIFICATIONS - W (Standard) H.5W (High pressure) Y Low wattage (0.5W) N Negative common Note) Except for AC and double (latching) type. C OIL V OLTAGE 3 0VAC (50/60Hz) 5 24VDC 6 2VDC Note ) The C kit is applicable to 200/220VAC. Contact SMC for other Kits. E LECTRICAL E NTRY G: grommet C kit single type only. (Except for AC). L: L type plug connector with lead wire L: O type plug connector without connector M: M type plug connector without connector MO: M type plug connector without connector Note ) LO and MO valves are used for F,P,T, and S kits. The plug connector and lead wire are attached to the manifold. ACCESSORIES MANIFOLD OPTIONS I NDIVIDUAL SUP SPACER VVQ000-P-4-C6 DIN RAIL M OUNTED B RACKET [-D] VVQ000-57A-4 I NDIVIDUAL EXH SPACER VVQ000-R-4-C6 B UILT I N S ILENCER, DIRECT E XHAUST [-S] N AMEPLATE [-N4] VVQ000-N4 Station (-Max. stations) S ILENCER (EXH PORT) AN03-X233 (VQ000) B LANKING P LUG KQP P R PR B LOCK V ALVE VQ P R- PR

8 S OLENOID VALVES 2.33 B ODY P ORTED T YPE P LUG L EAD U NIT/CASSETTE T YPE M A N I F O L D VV5Q 7 08 F U D VQ000 SUP/EXH PORT - Metric (mm) 00T Imperial (Inch) T YPE OF M ANIFOLD 7 Plug Lead unit/cassette type N UMBER O F S TATIONS 0 Station 6 6 Stations The number of stations differs from kit to kit. DIN RAIL/ OPTION Note ) Note 2) Note ) D N DIN rail mounted type With Nameplate Manifold is of a DIN rail mounted type, and so suffix D should be indicated. When the N option is desired, write as DN. K IT ELECTRICAL E NTRY C ABLE L ENGTH S EE INSIDE FRONT COVER FOR DETAILS OF YOUR LOCAL SALES OFFICE

9 2.34 S OLENOID VALVES V A L V E VQ000 C ONFIGURATION VQ 7 0 N 5 M C6 C YLINDER P ORTS C3 One Touch Fittings for Ø3.2 C4 One Touch Fittings for Ø4 C6 One Touch Fittings for Ø6 M5 M5 (0-32Nom) N One Touch Fittings ø/8 N3 One Touch Fittings ø5/32 N7 One Touch Fittings ø/4 Note ) The code is L for Elbow Piping for all Manifold Stations. Example L6: Elbow with One Touch Fittings. M ANUAL O VERRIDE Note ) Locking type (B) is used for the double (latching) type as standard. Must include B suffix. T YPE OF S EAL 0 Metal Rubber E LECTRICAL E NTRY L Type plug connector with lead wire LO Type plug connector without connector P ILOT V ALVE S PECIFICATIONS - W (Standard) H.5W (High Speed response) N Negative Common Note ) Y Low wattage (0.5W) Note) Except for 00/0VAC type. M Type plug connector with lead wire MO Type plug connector without connector C OIL V OLTAGE 3 0VAC 5 24VDC 6 2VDC With indicator light and surge voltage suppressor Note ) LO and MO valves are used for F,P, and S kits. Plug connector and lead wire layers are attached to the manifold. Note 2) Grommet type (G) is also available for C kit type. (Except for latching type and 00/0VAC) ACCESSORIES MANIFOLD OPTIONS SUP-EXH BLOCK P USH A SSEMBLY VVQ000-87A-B-50 N AMEPLATE [-N7] VVQ000-N7 Station (- Max. Stations) E LBOW F ITTINGS A SSEMBLY C3 VVQ000-F7-L C4 C6 B LANKING P LUG 23 KQP S ILENCER AN03-X233

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model 2 position 3 position

More information

Manifold Specifications Stacking Type

Manifold Specifications Stacking Type Specifications Stacking Type Keeps environmental air clean from pilot exhaust Use of the VV5FS- manifold can exhaust intensively the pilot exhaust gas to the base side, and can prevent environmental aggravation

More information

Manifold Specifications

Manifold Specifications Series 00 Manifold Specifications Manifold Specifications Model Manifold type P(SUP)/R(EXH) Valve stations A port porting specifications Port size For internal pilot For external pilot Location Direction

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

Manifold Specifications

Manifold Specifications Specifications Plug-in Type: With Terminal Block Since lead wires of solenoid valve are connected with the terminals on upper surface of terminal block, corresponding lead wires from power source can be

More information

VQ1000. How to Order Manifold. Kit type

VQ1000. How to Order Manifold. Kit type - - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold

More information

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000

More information

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer Base Mounted Metal Seal/Rubber Seal VQ Built-in silencer, direct exhaust Space-saving profile All pilot valves are compactly mounted on one side. The space-saving design of mounting all fittings on one

More information

Terminal Block Box (Spring Type) SY3000/5000/7000 Series

Terminal Block Box (Spring Type) SY3000/5000/7000 Series INFORMATION 5 ort olenoid alve Terminal lock ox (pring Type) Y3000/5000/7000 eries Compact RoH Height 6.7 mm shorter (Approx. 9% reduction) Installation area of the terminal block box Reduced by approx.

More information

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted

More information

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector

More information

Series VQZ1000/2000/3000 Single Unit

Series VQZ1000/2000/3000 Single Unit +- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body

More information

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series

More information

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308 Cable ppendix Cable ppendix Multi-way cables The multi-pole connector cables used on SMC valves are common across several ranges. Cables are available in accordance with the MIL standard C-08 and also

More information

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),

More information

How to Order Manifold. Kit type L8 B4 B6 B8 LM

How to Order Manifold. Kit type L8 B4 B6 B8 LM 0 Stations station VVQ Series VQ000 The maximum and minimum number of are varied depending on. (Refer to the table below.) Series VQ000 ase Mounted Plug-in Unit Manifold Plug-in unit 08 C Cylinder port

More information

Manifold Specifications

Manifold Specifications Specifications Specifications Base mounted VVFR-01 VVFR- VVFR-0 Wiring With terminal block With multi-connector With D-sub connector Grommet terminal DIN terminal Grommet Grommet terminal Conduit terminal

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles ort Solenoid Valve: ase Mounted Metal Seal/Rubber Seal Series Space and capacity saving ilot valve is gathered at one side. Space saving design which does not have any protrusions. Space saving Capacity

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

Plug Lead Unit: Flip Type

Plug Lead Unit: Flip Type Series ody orted lug Lead Unit: Flip Type For details about certified products conforming to international standards, visit us at www.smcworld.com. 0 Series Kit/Electrical entry/cable length F kit (D-sub

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

V50... V53 Series 3/2, 5/2 and 5/3 way valves Solenoid actuated and pilot operated 1/8... 1/2

V50... V53 Series 3/2, 5/2 and 5/3 way valves Solenoid actuated and pilot operated 1/8... 1/2 50... 5 eries /2, 5/2 and 5/ way valves olenoid actuated and pilot operated /8... /2 igh flow in-line valves ompact and robust design ow power energy efficient solenoids lexible in-line and manifold mounting

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

Example. U side. Stations SY5000

Example. U side. Stations SY5000 45 Type 5 ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN ail Mounted/Individual Wiring Series SY3000/5000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 3 45 05 U C6 Example

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry

More information

VAL /2, 5/2, 5/3, and 2 x 3/2 Directional control valves. 3-Port and 5-Port Air Pilot Valves

VAL /2, 5/2, 5/3, and 2 x 3/2 Directional control valves. 3-Port and 5-Port Air Pilot Valves 6-6 eries /, /, /, and x / irectional control valves igh flow rate xtensive manual override options Manifold system with easy assembly ow power consumption Maintenance-free echnical data Medium: ompressed

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type20P 5 Port Solenoid Valve ody Ported Manifold ar Stock Type/Flat Ribbon Cable Series SY3000/5000/7000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 5 20P 05 Manifold series 3 SY3000

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000 D-sub Connector J Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000//000 Number of connectors: pins MIL-C-08 Conforming to JIS-X-0 --6 For details

More information

Compact Vacuum Ejector

Compact Vacuum Ejector Compact acuum Ejector Series ZA Total length Total width 7.9 mm 9.9 mm Total height. mm Response time 0 ms Response time for up to 0 ka Nozzle diameter: ø0.7 iping: ø/ø. x 0 mm Able to install on the moving

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve ubber Seal / ort Solenoid Valve Series 000 / 000 / 000 [Option] SJ SY SV SZ V S000 VQ VQ VQ VQC VQZ SQ VFS VF VQ Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread

More information

ADEX Series. Air Control Valves. Section D

ADEX Series. Air Control Valves. Section D X Series ir ontrol alves 00.0 v.8 v.47 v ort 5 ort /8" ort Section www.parker.com/pneu/adex X iking Z asic alve unctions...00 asic alve eatures...0 ommon art umbers / R Type alves...02 odel umber Index

More information

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is. Port Solenoid Valve Series VQ 00 Unprecedented high speed, stable response, and extra-long service life. ON:.ms, OFF: ms, Dispension accuracy ±ms (With indicator light and surge voltage suppressor; supply

More information

ADEX Series Air Control Valves A00.01 Cv M3 Port A05.18 Cv M5 Port A12.47 Cv 1/8" Port zpv02 A B C D E F G H. Section H

ADEX Series Air Control Valves A00.01 Cv M3 Port A05.18 Cv M5 Port A12.47 Cv 1/8 Port zpv02 A B C D E F G H. Section H X Series ir ontrol alves 00.0 v ort 05.8 v 5 ort.47 v /8" ort zpv02 Section www.parker.com/pneu/adex asic alve unctions... 2 asic alve eatures... ommon art umbers / R Type alves... 4 odel umber Index /

More information

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating / ort Solenoid Valve ubber Seal Series SYJ000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Specifications JIS Symbol port port (manifold) position

More information

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1 Port Solenoid Valve Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Non plug-in manifold 0 0 S 60 Stations stations 0 stations SUP/EXH

More information

How to Order Manifold. Control unit Refer to pages to Kit/Electrical entry/cable length. kit (D-sub connector) U0 U1 U2

How to Order Manifold. Control unit Refer to pages to Kit/Electrical entry/cable length. kit (D-sub connector) U0 U1 U2 VQ000 ase Mounted Plug-in nit For details aout certified products conforming to international standards, visit us at www.smcworld.com. Type of connection VVQ VQ000 R port P port Port R Manifold Plug-in

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Series VQ Rubber Seal Space-saving profile Clean space saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Rubber Seal Series VQ Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type1P Type2P 5 Port Solenoid Valve ase Mounted Manifold ar Stock Type/Flat Ribbon Cable Series /5000/000 How to Order Manifold Type 1P/Compact style SS5Y 5 1P 05 C8 Manifold series 3 5, port size Thread

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

How to Order Single Unit 25A-ZK2 A 12 N 0 N N 08. e Combination of supply valve Note 3) and release valve. Note 5) K. Note 6)

How to Order Single Unit 25A-ZK2 A 12 N 0 N N 08. e Combination of supply valve Note 3) and release valve. Note 5) K. Note 6) Vacuum Unit RoHS Series 25A-ZK2 How to Order Single Unit Ejector System (with Valve) Ejector System (without Valve) 25A-ZK2 A 12 K 5 A 08 25A-ZK2 A 12 0 08 q w e r t y u i Remains blank when option is

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Port Solenoid Valve Metal Seal Rubber Seal Series Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

How to Order Single Unit 25A-ZK2 A 12 N 0 N N 08. e Combination of supply valve Note 3) and release valve. Note 5) K

How to Order Single Unit 25A-ZK2 A 12 N 0 N N 08. e Combination of supply valve Note 3) and release valve. Note 5) K Vacuum Unit RoHS Series 25-ZK2 How to Order Single Unit Ejector System (with Valve) Ejector System (without Valve) 25-ZK2 12 K 5 08 25-ZK2 12 0 08 q w e r t y u i Remains blank when option is not selected.

More information

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

Space Saving Vacuum Ejector/Vacuum Pump System

Space Saving Vacuum Ejector/Vacuum Pump System Space Saving acuum Ejector/acuum ump System Series Current 21.6 mm mm Width mm [Option] Weight 9 g Single unit with vacuum pressure switch and suction filter ZK2 ZR Z Z ZM ZL -X267 ZU Ejector.2 ump System.118

More information

Series ZQ. Compact Vacuum Ejector. One-touch fitting. Digital vacuum pressure switch With LED display. ZX ZR ZM ZH ZU ZL ZY ZQ ZF ZP ZCU AMJ Misc.

Series ZQ. Compact Vacuum Ejector. One-touch fitting. Digital vacuum pressure switch With LED display. ZX ZR ZM ZH ZU ZL ZY ZQ ZF ZP ZCU AMJ Misc. Compact acuum Ejector Series Body width mm, Weight9 g (Single unit with vacuum pressure switch and suction filter) Conventional 21.mm mm One-touch fitting ZR ZM ZH ZU ZL ZY ZF Z ZCU AMJ Misc. Digital vacuum

More information

Space Saving Vacuum Ejector / Vacuum Pump System

Space Saving Vacuum Ejector / Vacuum Pump System CT.US0-1'-UK Space Saving acuum jector / acuum ump System Conventional ZX 21. mm mm ZQ Series ZQ Width mm Weight 9 g Single unit with vacuum pressure switch and suction filter jector ump System NW asy-to-use

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and

More information

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications Series -SQ00 Port Solenoid Valve Plug-in Unit [Option] How to Order Manifold Electrical entry F kit D-sub connector kit P kit SSQ 08 FD Kit type Flat ribbon cable connector kit J kit Flat ribbon cable

More information

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring Type4 SY000/000 ase Mounted Monifold Stacking Type/DIN ail Mounted Individual Wiring How to Order Manifold SSY 4 0 U C6 How to Order Valve Manifold ssembly Ordering example SY000 SY000 Valve stations 02

More information

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve CT.E- ase Mounted Type Series VQ Port Metal Seal/Rubber Seal Solenoid Valve dvanced manifold va the new age of factory au ase Mounted Type Space saving profile Clean space saving design with all pilot

More information

How to Order Manifold. Option Symbol

How to Order Manifold. Option Symbol Series Plug Lead nit For details about certified products conforming to international standards, visit us at www.smcworld.com. Series/Manifold 12 Stations 01 1 station Kit/Electrical entry/cable length

More information

Rubber Seal VP300/500/700

Rubber Seal VP300/500/700 Port Pilot Operated Poppet Rubber Seal 00/500/700 High flow capacity Cv1.0 (00), Cv. (500), Cv.0 (700) Low power consumption: 1.8W(DC) Possible to use as either selector valve or divider valve Changeable

More information

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000) 5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust

More information

5 Port Solenoid Valve Plug Lead Type

5 Port Solenoid Valve Plug Lead Type 5 Port Solenoid alve Plug Lead Type Series Body Ported Flow rate characteristics For single/double solenoid C [dm 3 /(s bar)]: 0.6 Single Unit alve width: 7.4 mm Possible to drive cylinders: Up to ø32

More information

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles Port Solenoid Valve: ase Mounted Metal Seal/Rubber Seal Series VQ Space and capacity saving Pilot valve is gathered at one side. Space saving design which does not have any protrusions. Space saving Capacity

More information

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle. Multistage Ejector 112/212 Series Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus

More information

Series SYJ3000/5000/7000

Series SYJ3000/5000/7000 , ort Solenoid Valve ubber Seal Series SYJ000/000/7000 Low power consumption: 0.W(Without light) (Current draw: 1m at V DC) right color tone and state of the art design SY SYJ SX VK VZ VF VF V7 V Completely

More information

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit CT.EUS8 UK ower Consumption / ort Solenoid Valve With ower Saving Circuit Series SYJ000/000/7000 Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve CT.ES8 / ort Solenoid Valve Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M.7 to M2. 앬 Flow Characteristics Series Cover (stainless

More information

Base Mounted Plug-in/Plug Lead: Single Unit

Base Mounted Plug-in/Plug Lead: Single Unit ase mounted VQ ase Mounted lug-in/lug Lead: Single Unit Model Number of solenoids Model Single Metal seal VQ Rubber seal VQ ouble Metal seal VQ Rubber seal VQ Closed Metal seal VQ VQ center Rubber seal

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

Fieldbus System (Output device for driving 5 port solenoid valves)

Fieldbus System (Output device for driving 5 port solenoid valves) Fieldbus System (Output device for driving port solenoid valves) New Compact 8mm (ctual size) Space-saving Installation IP67 RoHS EtherNet/IP added! For units with D-sub connector, and when connected to

More information

3 Port Air Operated Valve

3 Port Air Operated Valve Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 044 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000 racket

More information

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection Rubber Seal Port Solenoid Valve Series SJ000/000 Cassette Type Manifold 0 mm 7. mm (SJ000) 0 mm (SJ000) Non plug-in type Individual wiring manifold SJ000 SJ000 Can be mounted together. Connecter connection

More information

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Body Ported Base Mounted Series S000 S000 S000 S000 S000 S4000 S5000 Sonic conductance C [dm /s bar)] 4/ 5/(A/B R/R) Single Double.8.4

More information

Single Valve/Sub-plate Type IP67 Compliant 90-SV Series

Single Valve/Sub-plate Type IP67 Compliant 90-SV Series Single Valve/Sub-plate Type IP7 Compliant -SV Series SV 00 W U aterial restriction Series -SV000 -SV000 Thread type c F G N NPT T NPTF A B SOL.a SOL.a Type of actuation position single (EA) (P)(EB) position

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series

More information

Gateway Type Serial Transmission System

Gateway Type Serial Transmission System P99-EX-B Gateway Type Serial Transmission System P Maximum 8 point control (64 inputs/64 outputs) P Flexibility of manifold valve installation improved with 4 branch wiring Flexible installation and removal

More information

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I ISO Standard Solenoid Valve Series VQ7-6/7-8 (Size ) (Size ) Conforms to ISO Standard /I.0- Ideal for driving cylinders up to Large flow capacity ø00 (VQ7-6, Size ) ø60 (VQ7-8, Size ) Nl/min VQ7-6: 668.

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry TEX Compliant Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 44 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000

More information

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type. Series -S00 ompact Direct Operated Port Solenoid Valve ontrol Valves ase mounted ody ported lean Series lean Series V S R oil voltage 24 VD VD VD VD VD Power consumption Pressure specification Flow rate

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M. V3 Cover

More information

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Vacuum Release Valve with Restrictor Series SJ3A6 SJ Plug-in Type Connector Connection P.86 D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Non Plug-in Type Individual

More information

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot ubber seal ort ilot Solenoid Valve Series SYJ00 Specifications efer to www.smcworld.com for details of products compatible with overseas standards. Body ported Base mounted Fluid Operating pressure range

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 0 PW COM Rubber Seal Port Solenoid Valve Series SZ000 Cassette Type Manifold The plug-in cassette system makes valve replacement easy. plug-in manifold has been created with a height of. mm (including

More information

3 million cycles. High Pressure Coolant Valve. SGH Series W (24 VDC) (With light/surge voltage suppressor: 0.58 W)

3 million cycles. High Pressure Coolant Valve. SGH Series W (24 VDC) (With light/surge voltage suppressor: 0.58 W) igh Pressure oolant Valve eries Pa/ orresponding to high speed grinding and long drilling processes oolant valve for high pressure coolant liquid (up to Pa/) that is ideal for lubrication, dust blowing

More information

VNA Application example. 3-port dual pressure, N.C. type SGH. Nozzle SGH. Coolant pump

VNA Application example. 3-port dual pressure, N.C. type SGH. Nozzle SGH. Coolant pump igh Pressure oolant Valve eries Pa/ orresponding to high speed grinding and long drilling processes oolant valve for high pressure coolant liquid (up to Pa/) that is ideal for lubrication, dust blowing

More information

Series PCW. PC Wiring System

Series PCW. PC Wiring System CT.ES0-0 PC Wiring System Series PCW The PC wiring system is a revolutionary new system that simplifies wiring between a PLC and all types of connected equipment. revolutionary new wiring system... 4VDC

More information

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal Port Solenoid Valve Cassette Type Manifold Rubber Seal 7.mm (SJ000) SJ000 SJ000 Can be mounted together. 0mm (SJ000) Connector connection New New cable type manifold is added! New Additional options are

More information

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC Base Mounted Series VQZ00/00/00 VQZ00/00 / How to Order Valve Made to Order (For details, refer to page 9 and 4.) VQZ 5 5 M Series VQZ00 body width 5 mm VQZ00 body width 8 mm Type of actuation 4 N.C. N.O.

More information

3 Port 3 Position Valve

3 Port 3 Position Valve Port Position Valve Pilot Solenoid ir Operated ohs Intermediate stopping of cylinders * up to ø15 is possible. Pilot solenoid Manifold ir operated * For VEX 4, 00 mm/s, horizontal movement Power consumption:

More information

Series SYJ300/500/700

Series SYJ300/500/700 ort Solenoid Valve ubber Seal Series SYJ00/00/00 Low power consumption: 0.W (Without light) (Current draw: 1m at 4V DC) Completely interchangeable ilot exhaust with the previous series VJ00/00/00 and VZ00/00.

More information