Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Size: px
Start display at page:

Download "Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non"

Transcription

1 Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Plug-in... 0 Specifications... 0 How to Order... Construction... Dimensions... Manifold Specifications... 8 Dimensions... Manifold with Control Unit... How to Order... 6 Dimensions... 7 Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Plug-in... 0 Specifications... 0 How to Order... Construction... Dimensions... Manifold Specifications... 8 Dimensions... Manifold with Exhaust Cleaner... How to Order... Dimensions... 6 Manifold with Control Unit... 8 How to Order... 9 Dimensions... 0 Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Plug-in... Specifications... How to Order... Construction... 7 Dimensions... 8 Manifold Specifications... 6 Dimensions... 6 Dimensions Manifold with Exhaust Cleaner How to Order Manifold with Control Unit... 7 How to Order... 7 Dimensions... 7 Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Plug-in Specifications How to Order Construction... 8 Dimensions... 8 Manifold Specifications... 8 Dimensions Manifold with Exhaust Cleaner How to Order Dimensions Series 6000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Plug-in... 9 Specifications... 9 How to Order... 9 Construction Dimensions... 98

2 Series Variations ase Mounted Series 000 Non plug-in type 000 Non plug-in type 000 Non plug-in type 000 Non plug-in type 6000 Non plug-in type Port Pilot Operated Solenoid Valve Rubber Seal Series Sonic conductance C [dm /(s bar)] /8, /:.0 /: 7. /8: 8.7 /8,/: /8: 8 /: /: /: Effective area : ( 9 mm ) Type of actuation position single ()() (E)(P) (E) position double ()() (E)(P)(E) position closed center ()() (E)(P)(E) position exhaust center ()() (E)(P)(E) position pressure center ()() (E)(P)(E) Voltage Electrical entry With light/surge voltage suppressor (Option) (Standard) 00 VC 0 /60 Hz 00 VC 0 /60 Hz VDC (Option) 0 to 0 V 0 /60 Hz 0 VC 0 /60 Hz 0 VC 0 /60 Hz VDC 00 VDC Plug-in Conduit terminal (F) Non plug-in Grommet (G) Conduit terminal (T) L plug connector (L) Plug-in Conduit terminal (F) Non plug-in Grommet terminal (E) (0/0) DIN terminal (D) Non plug-in (0/0) Grommet (G) Grommet terminal (E) Conduit terminal (T) Plug-in Conduit terminal (F) Non plug-in Grommet terminal (E) Plug-in Conduit terminal (F) Non plug-in Grommet terminal (E) Grommet terminal (E) DIN terminal (D, Y) M plug connector (M) DIN terminal (D, Y) DIN terminal (D) DIN terminal (D) With light/surge voltage suppressor Conduit terminal (FZ) Non plug-in type Grommet terminal (EZ) Conduit terminal (TZ) DIN terminal (DZ, YZ) With surge voltage suppressor Non plug-in type Grommet (GS) Note) Surge voltage suppressor is equipped midway on the lead wire for grommet type. With light/surge voltage suppressor Conduit terminal (FZ) Non plug-in type (0/0) DIN terminal (DZ) Grommet terminal (EZ) Conduit terminal (TZ) With surge voltage suppressor Non plug-in type (0/0) Grommet (GS) Note) Surge voltage suppressor is equipped midway on the lead wire for grommet type. With light/surge voltage suppressor Conduit terminal (FZ) Non plug-in type DIN terminal (DZ) Manual override Non-locking push type Non-locking push type (Extended) Locking type (Tool required) Locking type C (Lever) Non-locking push type VP S S VS N position single type Passage: / / (/ E/E) --

3 Series 000/000/000/000/6000 Manifold Variations ase Mounted Plug-in Type ase Mounted Non Plug-in Type Manifold With multi-connector With terminal block With D-sub connector Non plug-in type (Wiring required to each valve) Individual SUP spacer Manifold Option Parts Manifold Option Individual EXH spacer SUP block disk EXH block disk Throttle valve spacer Interface regulator lanking plate ir release valve spacer SUP stop valve spacer () Note ) Used with the manifold base. Please contact SMC for details. Note ) There is no manifold base in Series With exhaust cleaner, Non plug-in type High noise reduction effect: d or more Collects oil mist: collecting rate 99.9% Piping work is reduced. With control unit Note), Non plug-in type Filter, regulator, pressure switch and air release valve in one unit Piping work eliminated Note) There is no option with control unit in Series 000. () With serial interface unit for serial transmission Reduces wiring labor and material to manifold. Possible to locate separately. Manifold solenoid valve: Max. 8 stations, places ( solenoids) Easy maintenance For details, refer to another catalog separately. --

4 Series 000/000/000/000/6000 Precautions e sure to read before handling. For Safety Instructions and Solenoid Valve Precautions, refer to page --. (With terminal block) Series 000/000/000 If you remove the junction cover () on the subplate, you will see the plug-in terminal block () attached to the inside of sub-plate. The following markings are on the terminal block. Connect with corresponding power side. lthough, + and marks are indicated on the terminal block, this can be used as either +COM or COM. pplicable terminal: 000, 000:.-,.-S,.Y-N,.Y-S 000:.-.M,.Y-L,.Y-M Series 000 Remove junction cover for sub-plate (), depress levers () of terminal block assembly (), pull out terminal block assembly. E E - - COM.(+) + - () () Terminal block assembly is marked as below. Connect it to power supply side. Model Caution (Jumper bar) COM(+) + + Terminal block marking () side side side () () side solenoid Common (COM) terminal side solenoid E E - - COM.(+) () COM COM COM () side side () Lead Wire Connection Terminal block assembly can be used as + and common regardless of markings. Do not remove jumper bar because it is used for common connection. pplicable terminal:.-,.-m Series 6000 If you remove the junction cover () on the subplate, you will see the plug-in terminal block () attached to the inside of sub-plate. PE E Terminal block assembly is wired like the following figure. Connect it to each power supply side. Can be used as either +COM or COM. pplicable terminal:.-,.-m Non plug-in type Series 000 Series 000/000 (0/0) Type G: Lead wire comes directly from the solenoid part. Connect it with the power source. Grommet with DC voltage surge voltage suppressor has polarity. Connect red lead wire to + (positive) side and black to (negative) side. E PE side side series COM COM () () Position Model Left Center Right 60 side COM Surge voltage suppressor DC C Red (+) lack ( ) side side Type E, T, D, Y: In the case of DIN terminal block and terminal block, there is no polarity of positive [+] and negative [ ]. Connect no. and no. terminals with corresponding power side. Ground With DIN terminal block With terminal block pplicable cable O.D. Type T: ø6 to ø8 mm Type E: ø. to ø.8 mm Type D (Series 000): ø6 to ø8 mm Type D (Series 000/000): ø. to ø7 mm Type Y: ø. to ø7 mm ø. to ø7 mm pplicable crimp terminal Type E, T:.-,.-S,.Y-N,.Y- S (Round shape or Y shape crimp terminal cannot be used for Type D.) Series 000/000/000/6000 (0/0) DIN terminal block type Male pin terminal of DIN terminal block of solenoid valves are wired as shown below. Connect to corresponding terminal on the connector. Ground Terminal no. Internal wiring SOL. side SOL. side COM Ground Can be used as either +COM or COM. pplicable cable Cross section of the wire: 0. to. mm Cable O.D.: ø8 to ø0 pplicable crimp terminal shown below. 7 mm or less 7 mm or less mm or more Corresponding to R.- of JIS C 80 J.S.T. Mfg. Co., Ltd. Equivalent to R.- mm or more Proper tightening torque of the connector Connector set screw 0. to 0.6 N m Terminal screw 0. to 0.6 N m Incorrect connection of COM terminal (DIN terminal no. ) can cause damage on power source circuit. Terminal block type () Remove cover (), over terminal block () () attached to the inside of body. Connect with () corresponding power side. For a style with light and surge voltage suppressor, straightly pull out the light and surge voltage suppressor substrate () and then connect them. side side side terminal block terminal block side pplicable terminal: 000:.-,.-S,.Y-N,.Y-S 000:.-.M,.Y-L,.Y-M 000/6000:.-.M,.-L,.-M VP S S VS N --

5 Series 000/000/000/000/6000 Precautions e sure to read before handling. For Safety Instructions and Solenoid Valve Precautions, refer to page --. ttaching and Detaching Connectors Caution. To attach a connector, hold the lever and connector unit between your fingers and insert straight onto the pins of the solenoid valve so that the lever s pawl is pushed into the groove and locks.. To detach a connector, remove the pawl from the groove by pushing the lever downward with your thumb, and pull the connector straight out. Groove Pin Cover Connector Pin DC indicator Lever DC coil: lack + Red, lack Red Lead wire Socket part no. DXT70-7- Cover ttaching and Detaching Lead Wires with Sockets Peel. to.7 mm of the tip of lead wire, enter the core wires neatly into a socket and crimp it with a special crimp tool. e careful so that the cover of lead wire does not enter into the crimping part. Core wire Crimping crimping area area Core wire Socket Lead wire Hook 0. to 0. mm Max. cover diameter: ø.7 mm ttaching and Detaching Lead Wires with Sockets. ttaching Insert the sockets into the square holes of the connector (with + and indication) and, continue to push the sockets all the way in until the lock by hooking into the seats in the connector. (When they are pushed in, their hooks open and they are locked automatically.) Then confirm that they are locked by pulling lightly on the lead wires.. Detaching To detach a socket from a connector, pull out the lead wire while pressing the socket s hook with a stick having a thin tip (approx. mm). If the socket will be used again, first spread the hook outward. Socket Hook Insulation Connector Lead wire Series 000/6000 Light/Surge Voltage Suppressor 0 0 Refer to table for Series 000, 0, 0 type of Series 000/000 and 000/6000, and table for Series 000 Non plug-in type and 0, 0 type of Series 000/000. (00) Light/Surge voltage suppressor (00/600) Light/ Surge voltage suppressor Series 000 Series 000/000 Table () Series 000 (00) 0 0 Series 000/000 ( 0/ 0) Series 000/6000 Voltage Light/Surge voltage suppressor C and 00 VDC VDC or less (00/00) Light/Surge voltage suppressor Single solenoid Double solenoid Single solenoid Double solenoid Light/Surge voltage suppressor Non plug-in type (0/60) Light/ Surge voltage suppressor Non plug-in type (0/0) Light/Surge voltage suppressor Non plug-in type (0) Table () Series 000 (0) 0 0 Series 000/000 ( 0/ 0) Voltage C and 00 VDC VDC or less Light/Surge voltage suppressor Non plug-in type (0/0) Light/Surge voltage suppressor Light/Surge voltage suppressor SOL. or SOL. SOL. or SOL. For rated voltages between VDC to 99 VDC, please contact SMC. Light/Surge voltage suppressor is not available for grommet type. For grommet type with surge voltage suppressor, refer to page

6 Series 000/000/000/000/6000 Caution Plugging one of the cylinder ports ( or ) enables use as a normally closed (N.C.) or normally open (N.O.) port valve. It is convenient when port valve is needed on a manifold, etc., but it can t be used in special applications such as using as a nonleakage valve. Use it with the exhaust port leaving open. Solenoid valve Used as a Port Valve Plug Type of actuation Number of solenoids Double Single How to Exchange Solenoid Valves, Pilot Valve ssemblies How to exchange solenoid valves Loosen set screw and take solenoid valve out vertically, otherwise it may cause damage to the solenoid valve. Never remove valve at an angle. When mounting solenoid valve on to the base, plug pin assembly (base-side) into receptacle assembly (body-side) vertically. Tightening Torque for Mounting olt Model Pilot valve assembly Thread M ( pcs.) M ( pcs.) M ( pcs.) M ( pcs.) Tightening torque 0.6 N m 0.9 N m. N m. N m 000 M ( pcs.).8 N m 6000 M8 ( pcs.) 6 N m Note) For more information about the procedure, refer to the instruction manual. ase Series 000 Series 000/000/000 Solenoid valve Pin assembly Sub-plate Pin assembly Series 6000 Receptacle assembly port N.C. How to exchange pilot valve assemblies Possible to exchange pilot valve assemblies like the following figures. Note) Do not change the rated voltage. Pilot valve assembly Pilot cover Pilot valve assembly port N.O. Series 000 Pilot valve assembly Series 000/000/000 Pilot valve assembly Series 6000 Mounting screw Change Direction of DIN Connector/Cable Entry Unscrew retaining screw, pull off outer cover, rotate connector block through 80. Replace cover and tighten screw. How to Calculate the Flow Rate For obtaining the flow rate, refer to page --0. VP S S VS N Pin assembly Sub-plate series --

7 Series 000/000/000/000/ Specifications Interface regulator pplicable solenoid valve series Regulating port Maximum operating pressure Set pressure range mbient and fluid temperature Port size for connection of pressure gauge Weight (kg) Effective area at supply side (mm ) S at P = 0.7 MPa/P = 0. MPa Effective area at exhaust side (mm ) S at P = 0. MPa Interface Regulator P P E E RF000 RF00 RF00 RF P P P P.0 MPa () 0.0 to 0.8 MPa 0. to 0.8 MPa () to 60 C (No freezing) () M x 0.8 Rc Note ) Maximum operating pressure of solenoid valve is 0.9 MPa. Note ) Set the pressure within operating pressure range of solenoid valve. Note ) Solenoid valve: Max. 0 C Note ) Synthesized effective area with position. Note ) Operate an interface regulator only by applying pressure from the P port of the base, except when using it as a reverse pressure valve. To combine a pressure center valve and the and port pressure reduction interface regulator, use the RF000, RF000, or the RF000 model. To combine a reverse pressure valve and an interface regulator, use the RF000, RF000, or the RF000 model. The P port pressure reduction cannot be used. When combining a double check valve and an interface regulator, use a manifold or subplate as a basis, and stack them in the following order; the perfect spacer the interface regulator the valve. When a closed center valve is combined with the interface regulator s, port regulation, note that it cannot be used for intermediate stops of a cylinder because there is leakage from relief port on the regulator. Flow Characteristics (P ) (Condition: Inlet pressure 0.7 MPa when position solenoid valve is mounted.) JIS P port regulation RF00-00-P Outlet pressure (MPa) RF Outlet pressure (MPa) Caution port regulation Inlet pressure 0.7 MPa Flow rate (l/min (NR)) Inlet pressure 0.7 MPa port regulation RF P Outlet pressure (MPa) Outlet pressure (MPa) RF00-00-P RF Outlet pressure (MPa) Inlet pressure 0.7 MPa Flow rate (l/min (NR)) Inlet pressure 0.7 MPa Flow rate (l/min (NR)) Inlet pressure 0.7 MPa RF00-00-P 0.6 Inlet pressure 0.7 MPa 0. Outlet pressure (MPa) RF Inlet pressure 0.7 MPa 0. Outlet pressure (MPa) Flow rate (l/min (NR)) --6 Flow rate (l/min (NR)) Flow rate (l/min (NR)) Flow rate (l/min (NR))

8 Series 000/000/000/000/ Caution Lead Wire Connection Type 0T with Terminal lock Remove junction cover of manifold, exposing terminal block attached to the manifold block. Lead wires from solenoid valve are connected with the terminals on upper side of terminal block. (On the terminal block, lead wire is connected with both and sides of solenoid valve in accordance with the corresponding markings and on the block.) Connect each lead wire of power side corresponding to respective solenoid valve on the lower terminal block. Terminal block wiring specifications is in accordance with COM. Terminal block marking + Model 00 side COM 00 side COM 00 side COM side pplicable terminal:.-,.-s,.y-n,.y-s lthough, + and marks are indicated on the terminal block, 000 can be used as either +COM or COM. Terminal block marking Model Series 000 Series 000 side COM + side side COM COM Wiring area Markings side 00 side COM side pplicable terminal:.-.m,.y-l,.-m lthough, COM+ and marks are indicated on the terminal block, 000 can be used as either +COM or COM. Terminal block marking Model side side COM COM side 00 side COM side pplicable terminal:.-.m,.y-l,.-m lthough, + and marks are indicated on the terminal block, 000 can be used as either +COM or COM. Terminal block marking Model 00 Series 000 Series side COM 00 side COM side 00 side COM side pplicable terminal:.-.m,.y-l,.-m lthough, + and marks are indicated on the terminal block, 000 can be used as either +COM or COM. VP S S VS N --7

9 Series 000/000/000/000/ Caution Lead Wire Connection Manifold/Plug-in Type Type 0C Circular Connector Series 000/000/000/000 When multi-connector is used, mass-termination between power supply side and solenoid valve can be done. This saves the wiring connection labor. Wire connection specifications Lead wire for both solenoid and sides in manifold are connected to connector terminal as COM specifications. Type 0F D-sub Connector Series 000/000/000/000 MIL standard type D connector (Terminal: pins) has wide exchangeability and saves wiring labor. Wire connection specifications Lead wire for both solenoid and sides in manifold are connected to connector terminal as COM specifications. Fig. () U side (n) ()() () Fig. () U side (n) ()() () Manifold internal wiring Except 000 Note ) Maximum number is 8 stations. Note ) It is used as +COM and COM. Note ) Station numbers are started from D side although connector is mounted on D or U Side. pplicable Plug ssembly (Option) ssembly part no. VS VS VS VS VS VS VS Option Terminal no. Lead wire color Dot marking Terminal no. Lead wire color Dot marking Cable length. m m m 7 m 0 m m 0 m Cable Color List of Each Terminal No. --8 Connector terminal no. Multi-connector Orange Orange lack Yes rown Yes White station stations stations stations stations 6 stations 7 stations Max. 8 stations 6 White Yes lack Yes Connector terminal no. 7 Pink Component parts Plug pc. Cable clamp 068- pc. Socket 660- pcs. Cable VCTF cores x 0.7 mm made by Tyco Electronics MP K.K. Green 6 Green Yes 8 Pink Yes D side pplicable plug assembly (Option) VS Red 9 Gray 8 Red Yes 0 Gray Yes Control unit stations stations stations 6 stations 7 stations 9 lue Unused Connector terminal no. ir release valve station Pressure switch station Max. 8 stations 0 lue Yes Unused Yes Yellow Yellow Yes Light green rown Light green Yes Manifold internal wiring Connector terminal no. M.6 x 0. Note ) Maximum number is 8 stations. Note ) It is used as +COM and COM. Note ) Station numbers are started from D side although connector is mounted on D or U Side. pplicable Plug ssembly (Option) ssembly part no. VS000-- VS000-- VS000-- VS000-- VS000-- VS VS VS Option Terminal no. Lead wire color Dot marking Terminal no. Lead wire color Dot marking D-sub connector station stations stations stations stations 6 stations 7 stations Max. 8 stations Connector terminal no. Cable length. m m m 8 m 0 m m 0 m 0 m Cable Color List of Each Terminal No. D side pplicable plug assembly (Option) VS000-- Connector terminal no. ir release valve station Pressure switch station Control unit stations stations stations 6 stations 7 stations Max. 8 stations Except 000 Component parts Plug MIL standard type D connector Number of terminals: pins Cable: cores x 0. mm lack rown Red Orange Yellow Pink lue Purple Gray White White Yellow White lack lack Red Red Orange Yellow Pink lue Purple Gray Orange Red rown PinkGray lack White Red lack lack White lack White White Red Red White

10 For details about certified products conforming to international standards, visit us at 9 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series 000 JIS Model Type of actuation position position Single Double Closed center Exhaust center Pressure center Non plug-in type Plug-in Model position position Single Closed center Double Exhaust center Pressure center Non plug-in Port size Rc Max. operating cycle (Hz) 0 0 () Response time (ms) 0 or less 0 or less 0 or less 0 or less 0 or less Note ) [ ]: Denotes the normal position. Note ) Min. operating frequency is once in 0 days. (s per JIS 87) Note ) ased on dynamic performance test, JIS (0. MPa, Coil temperature: 0 C, at rated voltage, without surge voltage suppressor) 0 Note ) For 00-FZ- 0, ( ): 0-DZ- Standard Specifications Valve specifications Electricity specifications C [dm /(s bar)]. 0 0 Fluid Operating pressure range Flow characteristics () / (P /) / / (/ E/E) b 0.8 position single/ position position double mbient and fluid temperature Lubrication Manual override Mounting orientation Shock/Vibration resistance Enclosure Coil rated voltage llowable voltage fluctuation pparent power (C) () Power consumption (DC) () Electrical entry Cv 0.8 Inrush Holding C [dm /(s bar)].0 b 0.7 Cv [0.89] 0. [0.] 0.7 [0.7] [0.89] 0. [0.] 0.7 [0.7].8 [0.6] 0. [0.60] 0.68 [0.] [0.7] 0.6 [0.] 0.7 [0.] ir 0. to 0.9 MPa 0. to 0.9 MPa 0 to 0 C (No freezing. Refer to page --.) Not required () Non-locking push type Unrestricted 00/0 m/s () Dustproof 00, 00 VC (0/60 Hz), VDC to 0% of rated voltage.6 V/0 Hz,.0 V/60 Hz. V (. W)/0 Hz,. V (. W)/60 Hz.8 W Conduit terminal Grommet, Grommet terminal Non plug-in Conduit terminal, DIN terminal type L plug connector, M plug connector Note ) t rated voltage Note ) Use turbine oil Class (ISO VG), if lubricated. Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Option Specifications Pilot type Manual override Coil rated voltage Porting specifications Option External pilot Note) Non-locking push type (Extended), Locking type (Tool required), Looking type C (Lever) 0 to 0, 0, 0 VC 0/60 Hz, 00 VDC ottom ported With light/surge voltage suppressor Note) Operating pressure: 0 to 0.9 MPa Pilot pressure: position single/ position 0. to 0.9 MPa position double 0. to 0.9 MPa () () Weight (kg) 0. (0.) 0. (0.) 0. (0.) 0. (0.) 0. (0.) --9 VP S S VS N

11 Series How to Order F: Electrical entry Option Nil Z None With light/surge voltage suppressor Piping (P,,, E, E port) Nil Option Side ported ottom ported Port size (P,, port) Nil 0 0 Without sub-plate 8 E, E port: Rc /8 Thread type Nil F N T Rc G NPT NPTF Plug-in 00 F 0 Non plug-in How to Order Pilot Valve ssembly SF DZ 60 Coil rated voltage 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 to 0 VC 0/60 Hz 0 VC, 0/60 Hz VDC 6 VDC 7 0 VC, 0/60 Hz 9 Other Option --0 position single position double position closed center position exhaust center position pressure center Nil R 6 7 Manual override Nil Non-locking push type Non-looking push type (Extended) Locking type (Tool required) C Locking type C (Lever) Option Electrical entry, Light/Surge voltage suppressor F G GS D DZ DO DOZ Y YZ YO YOZ 0 Pilot type Internal pilot External pilot Option (External pilot is available only on sub-plate type.) Coil rated voltage 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 V to 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC VDC 0 VC, 0/60 Hz 9 Other Option Electrical entry Plug-in Grommet DIN terminal DIN terminal (DIN60) With connector Without connector With connector Without connector E Indicator light With surge voltage suppressor Option Option Nil Z S Pilot valve manual override ody type Non plug-in type None With light/surge voltage suppressor With surge voltage suppressor Indicator light is not available for grommet type. With surge voltage suppressor is available for grommet type only. Electrical entry G: Grommet Nil: Non-locking push type T TZ E EZ L LZ LO LOZ M MZ MO MOZ 0 : Non-looking push type (Extended) L: L plug connector M: M plug connector Conduit terminal Grommet terminal L plug connector L plug connector (Without connector) M plug connector M plug connector (Without connector) : Locking type (Tool required) C : Locking type C (Lever) E: Grommet terminal T: Conduit terminal D, Y: DIN terminal Electrical entry Indicator light With surge voltage suppressor ody type Non plug-in type

12 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series 000 Cylinder Speed Chart System Components System Solenoid valve C D E System C D Series 000 Rc 8 Series 000 Rc verage speed (mm/s) Use as a guide for selection. Please confirm the actual conditions with SMC Sizing Program. ore size Series CM Pressure 0. MPa Load factor 0% Stroke 00 mm Series M/C Note) Pressure 0. MPa Load factor 0% Stroke 00 mm Series CS Pressure 0. MPa Load factor 0% Stroke 000 mm ø0 ø ø ø0 ø0 ø0 ø6 ø80 ø00 ø ø0 ø E It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. Load factor: ((Load weight x 9.8)/Theoretical force) x 00% Note) The Series C has been changed to the Series C. Speed controller Silencer S000-0 N0-0 (S =. mm ) (S = mm ) S000-0 (S = mm ) S000-0 (S = mm ) S000-0 (S = mm ) S000-0 (S = mm ) N0-0 (S = mm ) N0-0 (S = mm ) N0-0 (S = mm ) N0-0 (S = mm ) Tube bore x Length T0 x m T060 x m T0806 x m T07 x m T09 x m How to Order Sub-plate ssembly Pilot type Nil Internal pilot R External pilot <Side ported> Thread type Plug-in 000 LP 0 Nil Rc Non plug-in S000 LS 0 F G <ottom ported> N NPT Plug-in 000 LP 0 T NPTF Non plug-in S000 LS 0 Note) Mounting bolts and gaskets are not attached. Perpendicular, upward actuation Horizontal actuation Piping port (P,, port) E, E port: Rc 8 VP S S VS N --

13 Series 000 Construction position single position double 0 0 Component Parts No. q w e r t y Closed center: 0 Exhaust center: 0 Pressure center: 0 Replacement Parts No.!!! Description ody Sub-plate Spool valve dapter plate dapter plate End plate Description Gasket Hexagon socket head screw Pilot valve assembly Sub-plate assembly position closed center/exhaust center/pressure center Material luminum die-casted luminum die-casted luminum, NR luminum die-casted luminum die-casted Resin Material NR Steel Note Platinum silver Platinum silver Platinum silver Platinum silver lack No. Description Material u Piston Resin i o Piston Junction cover Resin Resin!0 Light cover assembly Resin! Spool spring Stainless steel! Return spring Stainless steel This figure shows a closed center type. Part no /0/0 XT6-0- XT6-6 (M x ) XT6-0- XT6-6 (M x ) XT6-0- XT6-6 (M x ) Refer to How to Order Pilot Valve ssembly on page --0. Refer to How to Order Sub-plate ssembly on page --. Note --

14 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series 000 Plug-in position single/double, position closed center/exhaust center/pressure center position single: 00-F Rc /8, / (P,, bottom piping) -Rc /8 (E, E bottom piping) -ø. (Electrical entry) G / Manual override (Non-locking) -Rc /8 (E, E port) -Rc /8, / (P,, port) -ø (Mounting hole) ottom ported position double: 00-F- 0 0 position closed center: 00-F- position exhaust center: 00-F- position pressure center: 00-F- Manual override (Non-locking) -ø (Mounting hole) Light/Surge voltage suppressor (t FZ) Other dimensions are the same as the single type. M x 0.8 (PE port) (External pilot port) Manual override (Non-locking) ( ): Rc / 8 -ø (Mounting hole) Other dimensions are the same as the single type. 0 VP S S VS N --

15 Series 000 Non Plug-in position single Grommet: 0-G Rc /8, / (P,, bottom piping) -Rc /8 (E, E bottom piping) Manual override (Non-locking) M x 0.8 (PE port) ottom ported 00 (Lead wire length) Grommet terminal: 0-E- 0 0 Other dimensions are the same as the grommet type. D Y 0 0 DIN terminal: pplicable cable O.D. ø6 to ø8 [ø. to ø7] pplicable cable O.D. ø. to ø.8 [ ]: Type Y Other dimensions are the same as the grommet type. -ø (Mounting hole) -Rc /8 (E, E port) Light Light/Surge voltage suppressor (t DZ, YZ) Light Light/Surge voltage suppressor (t EZ) -Rc /8, / (P,, port) ( ): Rc / 8 Conduit terminal: 0-T- 0 pplicable cable O.D. ø6 to ø8 0 Light/Surge voltage suppressor (t TZ) Light Other dimensions are the same as the grommet type. L plug connector: 0-L- 0 0 M plug connector: 0-M- 0 0 Light/Surge voltage suppressor (t LZ) 00 (Lead wire length) Other dimensions are the same as the grommet type. Max (Lead wire length) Light/Surge voltage suppressor (t MZ) Other dimensions are the same as the grommet type. --

16 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series 000 Non Plug-in position double 0 Grommet: 0-G- 0 -Rc /8, / (P,, bottom piping) -Rc /8 (E, E bottom piping) -ø (Mounting hole) -Rc /8 (E, E port) D DIN terminal: Y 0 ottom ported ( ): Rc / 8 Grommet terminal: 0-E- 0 0 Conduit terminal: 0-T- 0 0 Light/Surge voltage suppressor (t EZ) Light Other dimensions are the same as the grommet type. pplicable cable O.D. ø6 to ø8 [ø. to ø7] Light/Surge voltage suppressor (t DZ, YZ) Light [ ]: Type Y Other dimensions are the same as the grommet type. pplicable cable O.D. ø. to ø.8 -Rc /8, / (P,, port) Manual override (Non-locking) Other dimensions are the same as the grommet type. L plug connector: 0-L- 0 0 M plug connector: 0-M- 0 0 Light/Surge voltage suppressor (t LZ) 00 (Lead wire length) Other dimensions are the same as the grommet type. pplicable cable O.D. ø6 to ø8 00 (Lead wire length) M x 0.8 (PE port) Light/Surge voltage suppressor (t TZ) Light 00 (Lead wire length) Light/Surge voltage suppressor (t MZ) Other dimensions are the same as the grommet type. VP S S VS N --

17 Series Non Plug-in position closed center/exhaust center/pressure center Grommet Closed center: 0-G- Exhaust center: 0-G- Pressure center: 0-G Rc /8, / (P,, bottom piping) -Rc /8 (E, E bottom piping) M x 0.8 (PE port) Grommet terminal 0 Closed center: 0-E- 0 Exhaust center: 0-E- Pressure center: 0-E- Other dimensions are the same as the grommet type. DIN terminal D 0 Closed center: 0- Y- 0 Exhaust center: 0- D Y- Pressure center: 0- D- [ ]: Type Y Other dimensions are the same as the grommet type. -ø (Mounting hole) -Rc /8 (E, E port) Light/Surge voltage suppressor (t EZ) Light pplicable cable O.D. Y 0 ø6 to ø8 [ø. to ø7] Light/Surge voltage suppressor (t DZ, YZ) Light pplicable cable O.D. ø. to ø.8 -Rc /8, / (P,, port) Manual override (Non-locking) L plug connector Closed center: 0-L- 0 0 Exhaust center: 0-L- Pressure center: 0-L- Light/Surge voltage suppressor (t LZ) Conduit terminal Closed center: 0-T- Exhaust center: 0-T- Pressure center: 0-T Other dimensions are the same as the grommet type. pplicable cable O.D. ø6 to ø8 00 (Lead wire length) ( ): Rc / Light/Surge voltage suppressor (t TZ) Light Max. 0 Max (Lead wire length) Other dimensions are the same as the grommet type. M plug connector 0 Closed center: 0-M- 0 Exhaust center: 0-M- Pressure center: 0-M- 00 (Lead wire length) Light/Surge voltage suppressor (t MZ) Other dimensions are the same as the grommet type. --6

18 7 Series 000 Manifold Specifications Manifold Specifications ase model V-0 Non plug-in type V-0 Wiring With terminal block With multi-connector With D-sub connector Grommet Grommet terminal Conduit terminal DIN terminal L plug connector M plug connector How to Order Manifold ssembly Porting specifications Port size, port P, E, E, Note) Side/ottom 8, C6, C8 <Example> with terminal block (6 stations, one-piece junction cover) V-0T-06-0 set (Manifold base part no.) 00-FZ sets ( position single part no.) 00-FZ sets ( position double part no.) VS000-0 set (lanking plate assembly part no.) Plug-in Type: With Terminal lock Since lead wires of solenoid valve are connected with the terminals on upper surface of terminal block corresponding lead wires from power source can be wired at the bottom of terminal block. U side Note) Side ported and bottom ported cannot be taken at the same time. The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Valve arrangement is counted from the D side. When ordering, specify the part nos. in order from the st. station in the D side. When entry of part numbers becomes complicated, indicate on the manifold specification sheet. Individual junction cover V to to 8 to pplicable valve model 00-F 0-G 0-E 0-T 0-D 0-L 0-M <Example> Non plug-in type: 6 stations V set (Manifold base part no.) 0-D sets ( position single part no.) 0-D set ( position exhaust part no.) VS000-R-0- set (Individual EXH spacer part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. 0T Series 000 Manifold with terminal block Junction cover Nil Individual junction cover One-piece junction cover 0 stations stations 08 0 Passage Porting specification P E, E, Side Common Common ottom Side Common Individual ottom Side 6 Individual Common ottom 7 Side 8 Individual Individual ottom Option Plug-in Type: With Multi-connector (For wiring specifications, refer to page --8.) Master connection of power and solenoid valves. Quick wiring permits ease of installation. U side Multi-connector D side One piece junction cover U side D side Conduit wiring D U D side V 0C Series 000 Manifold with multi-connector Connector mounting Junction cover direction One-piece D side mounting junction cover U side mounting 0 stations Max. 8 stations 08 Valve arrangement is counted from the D side. When ordering, specify the part nos. in order from the st. station in the D side. When entry of part numbers becomes complicated, indicate on the manifold specification sheet. 8 stations Port size P, E, E 0 0, 8 C6 One-touch fitting for ø6 C8 D 0 0 Passage P M Porting specification E, E, Side Common Common ottom Side Common Individual ottom Side Individual Common 6 ottom 7 Side Individual Individual 8 ottom Option One-touch fitting for ø8 Mixed For bottom ported, /8 is only available. C8 M One-touch fitting for ø8 Thread type Nil Rc F G N NPT T NPTF Port size P, E, E, Nil 0 8 F 0 N One-touch C6 T fitting for ø6 Mixed For bottom ported, /8 is only available. Thread type Rc G NPT NPTF --7 VP S S VS N

19 Series Plug-in Type: With D-sub Connector (For wiring specifications, refer to page --8.) Wide range of interchangeability (D-sub connector (P) conforming to MIL standard) Quick wiring permits easier installation. U side D-sub connector D U V Series 000 Manifold with D-sub connector Connector mounting direction D side D side mounting U side mounting 0F Junction cover One-piece junction cover 0 stations Max. 8 stations 08 8 stations U 06 0 Porting specifications E, E, Passage P Side Common Common ottom Side Common Individual ottom Side Individual Common 6 ottom 7 Side Individual Individual 8 ottom Option Port size P, E, E 0 0 C6 C8 M, 8 One-touch fitting for ø6 One-touch fitting for ø8 Nil F N T Mixed For bottom ported, /8 is only available. Thread type Rc G NPT NPTF Note) P port or E/E port of symbol to 8 can be individual port with block plate. Therefore, if using individual SUP spacer or individual EXH interface for individual port, its symbol is. Non Plug-in Type: Grommet, Grommet Terminal, Conduit Terminal, DIN Terminal Wiring for every valve V Series 000 Manifold Non plug-in type 0 0 stations stations 0 0 Porting specifications E, E, Passage P Side Common Common ottom Side Common Individual ottom Side Individual Common 6 ottom 7 Side Individual Individual 8 ottom Option Note) P port or E/E port of symbol to 8 can be individual port with block plate. Therefore, if using individual SUP spacer or individual EXH spacer for individual port, its symbol is. Port size Thread type P, E, E 0 0, 8 Nil F N Rc G NPT C6 One-touch T NPTF fitting for ø6 C8 One-touch fitting for ø8 M Mixed For bottom ported, /8 is only available. --8

20 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series Manifold/Option Parts ssembly Individual SUP spacer Setting individual SUP spacer on the manifold block enables individual SUP port for each valve. Non plug-in type ody type Rc 8 VS000-P-0- VS000-P-0- Rc VS000-P-0- VS000-P-0- Part no. Individual EXH spacer Setting individual EXH spacer on the manifold block enables individual EXH port for each valve. EXH block disk When valve exhaust affects the other stations in the circuit, insert EXH block disk in between stations to separate valve exhaust. Throttle valve spacer Needle valve set on the manifold block can control cylinder speed by throttling exhaust. Interface regulator Interface regulator set on the manifold block can regulate pressure for each valve. (Refer to Flow Characteristics on page - -6 before operation.) ody type Non plug-in type Rc 8 VS000-R-0- VS000-R-0- ody type Non plug-in type Rc VS000-R-0- VS000-R-0- P port regulation RF P- RF P- Part no. SUP block disk When supplying manifold with more than two different kinds of pressure, high and low, insert a block disk in between stations subjected to different pressures. ody type Non plug-in type Part no. XT6- ody type Non plug-in type Part no. XT6- ir release valve spacer Valve 0 (single) can be used as air release valve by combining with release valve spacer. SUP stop valve spacer Note) If SUP stop valve spacer is set, valve can be removed for maintenance without stopping air pressure supply for other valves. lanking plate It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. ody type Non plug-in type Part no. VS VS ody type Non plug-in type Part no. VS000-0 ody type Non plug-in type L L Part no. VS000-- R VS000-- R Note) L: U side mount R: D side mount ody type Non plug-in type Part no. VS VS (Height will be. mm higher.) Note) Used with manifold base. Please contact SMC for details. Manifold Option With control unit Plug-in/Non Filter, regulation valve, pressure switch and air release valve all combine to form one unit. Piping processes are eliminated. For details, refer to page --. With serial interface unit for serial transmission Solenoid valve wiring process reduced considerably. Disperse installation possible. Manifold solenoid valve: 8 stations max, positions ( solenoids). Maintenance and inspection are easy. For details, refer to Serial Transmission catalog separately. VP S S VS N --9

21 Series Manifold With terminal block (Individual junction cover): V-0T- Station - Port size n-rc /8 U side (Pitch) P = 8 L ottom ported: V-0T- Station - Port size With terminal block (One-piece junction cover): V-0T- Station - Port size n-rc /8 ottom ported: V-0T- Station - Port size L L Rc /8 (PE port) -G / (Electrical entry) -Rc /8 (PE port) -G / (Electrical entry) n: Formula L = 8 x n + 7 L = 8 x n + 6 n-rc /8, / C6, C8 (, port) D side Light/Surge voltage suppressor (t FZ) 6-Rc / (P, E, E port) U side n-rc /8, / C6, C8 (, port) D side Light/Surge voltage suppressor (t FZ) 6-Rc / (P, E, E port) C6, C8 C6, C8 C6: Max. 6 C8: Max. 6. (Pitch) P = 8 C6: Max. 6 C8: Max

22 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series 000 Manifold With multi-connector: V-0CD- Station - Port size, V-0CU- Station - Port size L n-rc /8 ottom ported: CD V-0 - Station - Port size CU C6, C8 With D-sub connector: V-0FD- Station - Port size, V-0FU- Station - Port size n-rc /8 ottom ported: V-0 FD- Station - Port size L L For wiring specifications, refer to page --8. FU Plug assembly: VS Option: Refer to page Rc /8 (PE port) For wiring specifications, refer to page --8. n: Formula L = 8 x n + 7 L = 8 x n + 6 Plug assembly: VS000-- Option: Refer to page Rc /8 (PE port) U side D side n-rc /8, / C6, C8 (, port) Light/Surge voltage suppressor (t FZ) 6-Rc / (P, E, E port) U side D side Light/Surge voltage suppressor (t FZ) 6-Rc / (P, E, E port) n-rc /8, / C6, C8 (, port) C6, C8 (Pitch) P = 8 C6: Max. 6 C8: Max. 6. (Pitch) P = 8 C6: Max. 6 C8: Max. 6. VP S S VS N --

23 Series 000 Manifold Grommet: G Non plug-in type: V-0- Station - Port size n-rc /8 Manual override (Non-locking) L ottom ported: V-0- Station - Port size Grommet terminal: E Conduit terminal: T DIN terminal: D, Y L plug connector: L L L 7 8 Light/Surge voltage suppressor (t EZ) Light/Surge voltage suppressor (t LZ) pplicable cable O.D. ø. to ø (Lead wire length) 6 7 M plug connector: M 00 (Lead wire length) Rc /8 (PE port) 6-Rc / (P, E, E port) Light/Surge voltage suppressor (t TZ) n: Formula L = 8 x n + 7 L = 8 x n + 6 pplicable cable O.D. ø6 to ø8 Light/Surge voltage suppressor (t MZ) 00 (Lead wire length) n-rc /8, / C6, C8 (, port) [ ]: Type Y C6, C8 Light/Surge voltage suppressor (t DZ, YZ) C6: Max. 6 C8: Max. 6. pplicable cable O.D. ø6 to ø8 [ø. to ø7] --

24 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series 000 Manifold/Option Parts ssembly Individual SUP spacer: 0 VS000-P- 0 - () VS000-P- 0 - (Non plug-in type) 0 /Non plug-in type Throttle valve spacer: VS () VS (Non plug-in type) Throttle valve spacer Individual SUP spacer Rc /8, / SUP port Individual EXH spacer: 0 VS000-R- 0 - () VS000-R- 0 - (Non plug-in type) 0 Individual EXH spacer SUP block disk: XT6- EXH block disk: XT6- locking plate Rc /8, / EXH port Interface regulator RF P- () RF P- (Non plug-in type) Release valve spacer R VS000-- L () R VS000-- (Non plug-in type) L Interface regulator Valve 0 (Single) Release valve spacer Rc / SUP port Note) VS000--/R (D side mounting) VP S S VS N --

25 Series 000 Manifold with Control Unit Control unit (Filter, Regulator, Pressure switch, ir release valve) are all standardized to the one unit, and can be mounted on the manifold base without any attachments. Piping processes are eliminated. Manifold Specifications Wiring Manifold pplicable valve model : V-0 With terminal block With multi-connector With D-sub connector 00-F Non plug-in type: V-0 Grommet, Grommet terminal Conduit terminal, DIN terminal L plug connector, M plug connector 0-G, 0-E 0-T, 0-DY 0-L, 0-M Common SUP, Common EXH Porting specifications, port Side: Rc Rc /8, /, C6, C8, ottom: Rc /8 (Option) P, E, E port Side: Rc /, ottom: Rc /8 (Option) to stations (With multi-connector/d-sub connector: to 8 stations) Including station of control unit Non plug-in type Caution ir filter with auto-drain or manual drain must be mounted with the air filter at the bottom. Control Unit Specifications ir filter (With auto-drain/with manual drain) Filtration degree µm Regulator Set pressure 0.0 to 0.8 MPa (Outlet pressure) Pressure switch Set pressure 0. to 0.6 MPa range: OFF Differential 0.08 MPa Contact a Indicator light LED (RED) Max. switch capacity V C, W DC Max. operating VC, DC or less: 0 m current 00 VC, DC: 0 m Inside voltage drop V or less ir release valve (Single only) Operating 0. to 0.9 MPa pressure range Control Unit/Option ir release valve spacer Pressure () switch lanking plate () <> VS000--R (D side mounting) VS000--L (U side mounting) <Non plug-in type> VS000--R (D side mounting) VS000--L (U side mounting) IS000P-- For filter regulator For pressure switch For air release valve MP- MP- XT6-8 Filter - element Note ) Refer to Manifold Option on page --. Note ) Pressure switch cannot be mounted later on non plug-in type. --

26 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series 000 V 0 Series 000 Manifold ase model 0T 0T 0CD 0CU 0FD 0FU 0 Electrical entry terminal block multi-connector D-sub connector Non plug-in type Connector mounting direction D side U side Junction cover Stacking type Integrated type Integrated type Integrated type D side U side 0 stations 08 0 P Note) stations Note) 0CD, 0CU, 0FD, 0FU: Max. 8 stations 0T, 0T, 0: Max. stations Including station of control unit Porting Passage specifications P E, E (, ) Side Common Common ottom Side Common Individual ottom Side 6 Individual Common ottom 7 Side 8 Individual Individual ottom Option P port or E/E port of symbol to 8 can be individual port with block disk. Therefore, if using individual SUP spacer or individual EXH spacer for individual port, its symbol is. How to Order Manifold ssembly <Example> with terminal block V-0T-09-0-MP set (Manifold base part no.) 00-FZ sets ( position single part no.) 00-FZ sets ( position double part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. The st and nd station are used for control unit mounting. When ordering, specify the part nos. in order from the rd. station in the D side. When entry of part numbers becomes complicated, indicate on the manifold specification sheet. How to Order Port size P, E, E 0 0 C6 C8 M Control unit type Control equipment Nil MP P M G F C E ir release valve ir filter regulator with manual drain ir filter regulator with auto-drain Pressure switch lanking plate (ir release valve) lanking plate (Filter regulator) lanking plate (Pressure switch) Required stations stations station Thread type Nil Rc F G N NPT T NPTF Note) Control unit is D side mounting only., 8 One-touch fitting for ø6 One-touch fitting for ø8 Mixed ir release valve coil rating Nil None 00 VC, 0/60 Hz VDC 9 Other <Example> Non plug-in type V M set (Manifold base part no.) 0-D sets ( position single part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. The st and nd station are used for control unit mounting. When ordering, specify the part nos. in order from the rd. station in the D side. When entry of part numbers becomes complicated, indicate on the manifold specification sheet. VP S S VS N --

27 Series Manifold with Control Unit /Non plug-in type : Example for manifold V-0T- Station - Port size - Control unit Voltage of air release valve Individual EXH spacer U side n-rc /8, / C6, C8 Individual SUP spacer Light/Surge voltage suppressor Control unit Pressure switch Non plug-in type: V-0- Station - Port size - Control unit Voltage of air release valve Pressure switch Electrical entry -Rc /8 Pilot EXH port -G / Electrical entry -Rc /8 Pilot EXH port Pressure switch ir release valve D side 6-Rc / (P, E, E port) U side n-rc /8, / C6, C8 (, port) Pressure switch Rc / Po port Rc / Po port ir release valve D side 6-Rc / (P, E, E port) L L L L (MP) L (P) Control unit Example for manifold ir release valve Filter regulator Individual EXH spacer Individual SUP spacer Pressure switch ir release valve Control unit Filter regulator n: Formula L = 8 x n + 7 L = 8 x n + 6 L = 8 x n + 9 L = 8 x n

28 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series Manifold ase Construction /Non plug-in type End plate (D side) End plate (U side) Replacement Parts No. q w e r t y u i Description Connection fitting Connection fitting Gasket Gasket O-ring O-ring O-ring dapter plate assembly dapter plate Material Steel plate Steel plate NR NR NR NR NR Replacement Parts: Sub ssembly!0!! Manifold block assembly () End plate (U side) assembly End plate (D side) assembly Resin For 0T For 0T For 0C For 0F For 0SU C6 C8 C6 C8 XT6-0- () XT6--0 XT6--0 XT6--0 XT6--0 Part no. XT6-- XT6- XT6-7 XT6-6 8 x x. 0. x 7. x. 8 x x. XT6-8- (Terminal and adapter plate) XT6-8- V XT6-6 No. Description Material Part no. For 0T XT6-8- o For 0T Junction cover XT assembly For 0C For 0F V For 0SU Z78-0-! Rubber plug NR For 0T For 0SU XT6- Note) Manifold ase/construction: with terminal block. No. Description ssembly part no. Component parts pplicable manifold base () Manifold block!0, Metal joint q, w, O-ring t, y, u Terminal i, XT6-0- Junction cover o, daptor plate, Pin housing, Guide Note ) For side ported Note ) :, port size Rc / 8, :, port size Rc / Note ) Please contact SMC if parts except for 0/0T/0T are needed. Manifold block!0, Metal joint q, w, O-ring t, y, u End plate (U)!, Metal joint q, w, Gasket e, Guard! End plate (U)!, Metal joint q, w, Gasket e, Guard! End plate (D)!, Metal joint q, w, Gasket r, Guard!, Steel ball End plate (D)!, Metal joint q, w, Gasket r, Guard!, Steel ball Non plug-in type () For 0T With terminal block 0T Non plug-in type (For 0) () For 0T () With terminal block 0T Non plug-in type (For 0) () --7 VP S S VS N

29 8 --8

30 For details about certified products conforming to international standards, visit us at 9 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series 000 JIS position position Single Closed center Model position position Double Type of actuation Single Double Closed center Exhaust center Pressure center Plug-in Non plug-in type Exhaust center Pressure center Model Non plug-in 0 0 Port size Rc Standard Specifications Option Specifications C [dm /(s bar)] 0 0 Max. () operating cycle (Hz) () Response time (ms) 0 or less 0 or less 0 or less 0 or less 0 or less Note ) [ ]: Denotes the normal position. Note ) Min. operating frequency is once in 0 days. (s per JIS 87) Note ) ased on dynamic performance test, JIS (0. MPa, Coil temperature: 0 C, at rated voltage, without surge voltage suppressor) 0 Note ) For 00-FZ-, ( ): 0-DZ-, < >: 0-G- Valve specifications Electricity specifications 0 Fluid Operating pressure range mbient and fluid temperature Lubrication Manual override Mounting orientation Shock/Vibration resistance Enclosure Coil rated voltage llowable voltage fluctuation Inrush pparent power (C) () Holding Power consumption (DC) () Electrical entry Flow characteristics () / (P /) / / (/ E/E) b position single/ position position double Cv C [dm /(s bar)] [.] 0. [0.7].0 [0.96] [.] 0.9 [0.6]. [0.96] 7.6 [.] 0. [0.8].9 [0.69] [.] 0. [0.7]. [0.69] ir 0. to 0.9 MPa 0. to 0.9 MPa 0 to 0 C (No freezing. Refer to page --.) Non-lube () Non-locking push type Unrestricted 00/0 m/s () Dustproof 00, 00 VC (0/60 Hz), VDC to 0% of rated voltage.6 V/0 Hz,.0 V/60 Hz. V (. W)/0 Hz,. V (. W)/60 Hz.8 W Conduit terminal Grommet, Grommet terminal Non plug-in type Conduit terminal, DIN terminal Note ) t rated voltage Note ) Use turbine oil Class (ISO VG), if lubricated. Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Pilot type Manual Main valve override Pilot valve Coil rated voltage Porting specifications Option External pilot Note) Direct manual override Non-locking push type (Extended), Locking type (Tool required), Locking type C (Lever) 0 to 0, 0, 0 VC 0/60 Hz, 00 VDC ottom ported With light/surge voltage suppressor Note) Operating pressure: 0 to 0.9 MPa Pilot pressure: position single/ position 0. to 0.9 MPa position double 0. to 0.9 MPa b Cv () Weight (kg) 0.6 (0.6) <0.8> 0.7 (0.7) <0.69> 0.7 (0.7) <0.7> 0.7 (0.7) <0.7> 0.7 (0.7) <0.7> VP S S VS N --9

31 Series How to Order F:, conduit terminal Electrical entry Option Plug-in 0 0 F 0 Nil Z Porting specifications (P,, E, E port) None With light/surge voltage suppressor Nil Side ported ottom ported Option Port size (P,,, E, E port) Nil 0 0 Without sub-plate 8 For bottom ported: Rc / Thread type Nil F N T Rc G NPT NPTF Non plug-in D 0 Common electrical entry Non plug-in 0 G 0 position single position double position closed center position exhaust center position pressure center SF F 70 Coil rated voltage Rated voltage 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 to 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC 6 VDC 7 0 VC, 0/60 Hz 9 Other Option ody option 0 Standard Direct manual override Option Pilot type Nil R Option 6 7 Electrical entry, Light/Surge voltage suppressor F G GS E EZ T TZ D DZ Y YZ Internal pilot External pilot Coil rated voltage 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 to 0 VC 0/60 Hz 0 VC, 0/60 Hz VDC VDC 0 VC, 0/60 Hz 9 Other Option G: Grommet E: Grommet terminal How to Order Pilot Valve ssembly Electrical entry Plug-in Grommet Grommet terminal Conduit terminal DIN terminal DIN terminal (DIN60 type) Indicator light With surge voltage suppressor Option/ Nil Z Nil Z S pplicable valve model 0 None With light/surge voltage suppressor Option/ None With light/surge voltage suppressor With surge voltage suppressor Indicator light is not available for grommet type. With surge voltage suppressor is available for grommet type only. Electrical entry: E: Grommet terminal D: DIN terminal Electrical entry: T: Conduit terminal D, Y: DIN terminal Manual override Nil C Option Non-locking push type Non-locking push type (Extended) Locking type (Tool required) Locking type C (Lever) Individual electrical entry Pilot valve manual override Nil: Non-locking push type : Non-locking push type (Extended) : Locking type (Tool required) C : Locking type C (Lever) Option pplicable valve model 0 0, : Pilot valve assembly is all plug-in (F). Nil --0

32 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series 000 Cylinder Speed Chart System System Solenoid valve Series 000 Rc Series 000 Rc 8 <Side ported> verage speed (mm/s) It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. Load factor: ((Load weight x 9.8)/Theoretical force) x 00% System Components Pilot type Nil R Speed controller S000-0 (S = mm ) S0-0 (S = 7 mm ) Internal pilot External pilot Silencer N00-0 (S = mm ) N00-0 (S = 60 mm ) How to Order Sub-plate ssembly Plug-in 000 P 0 Non plug-in S000 S 0 <ottom ported> Plug-in 000 P 0 Non plug-in S000 S 0 Use as a guide for selection. Please confirm the actual conditions with SMC Sizing Program. ore size Series M Pressure 0. MPa Load factor 0% Stroke 00 mm Series CS Pressure 0. MPa Load factor 0% Stroke 000 mm ø0 ø0 ø6 ø80 ø00 ø ø0 ø60 ø80 ø00 Note) Mounting bolts and gaskets are not attached. SPG (Steel pipe) dia. x Length 6 x m 0 x m Piping port (P,,, E, E port) 0 0 Piping port (P,,, E, E port) 0 8 Thread type Nil F N T Rc G NPT NPTF Perpendicular, upward actuation Horizontal actuation VP S S VS N --

33 Series 000 Construction position single position double 0 0 Closed center: 0 Exhaust center: 0 Pressure center: 0 Component Parts No. q w e r t Replacement Parts No. Description ody Sub-plate Spool valve dapter plate End plate Description! Gasket NR!! Hexagon socket head screw Pilot valve assembly Steel Sub-plate assembly -- position closed center/exhaust center/pressure center Material luminum die-casted luminum die-casted luminum, NR Resin Resin Material Note Platinum silver Platinum silver lack lack XT6-(M x ) No. Description Material y Piston Resin u i Piston Junction cover Resin Resin o Light cover Resin!0 Return spring Stainless steel Part no XT6-(M x ) Refer to How to Order Pilot Valve ssembly on page --0. Refer to How to Order Sub-plate ssembly on page --. This figure shows a closed center type. Note // XT6-(M x )

34 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series 000 Plug-in position single/double, position closed center/exhaust center/pressure center 0 position single: 0 -FZ -ø.6 mounting hole Light/Surge voltage suppressor -ø. Electrical entry Manual override (Non-locking) G / (With direct manual override) 0 position single: 0 -FZ Light/Surge voltage suppressor -ø.6 (Mounting hole) -Rc /8, / -ø.6 (Mounting hole) Other dimensions are the same as the single type. -Rc / ottom ported (External pilot port) Rc /8 (PE port) ( ): Rc / position closed center: 0 -FZ position exhaust center: 0 0 -FZ 0 position pressure center: 0 -FZ Light/Surge voltage suppressor -ø.6 (Mounting hole) Other dimensions are the same as the single type. 0 VP S S VS N --

35 Series 000 Non Plug-in position single/double, position closed center/exhaust center/pressure position single: -E, -DZ 0 0 -ø.6 mounting hole -Rc / ottom ported Rc /8 (PE port) pplicable cable O.D. ø8 to ø0 Manual override (Non-locking) 0 -Rc /8, / 0 position double: -E, -DZ position closed center: -E, -DZ 0 0 position exhaust center: -E, -DZ 0 0 position pressure center: -E, -DZ -ø.6 (Mounting hole) (With direct manual override) Electrical entry (ø.) Max. 0 Other dimensions are the same as the single type. -ø.6 (Mounting hole) (Grommet terminal) -ø.6 (Mounting hole) (External pilot port) 0 Rc /8 (PE port) ( ): Rc / Other dimensions are the same as the single type. 0 --

36 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series 000 Non Plug-in position single 0 position single: -G Rc /8 (PE port) (With direct manual override: 0) E: Grommet terminal T: Conduit terminal D, Y: DIN terminal pplicable cable O.D. ø. to ø.8 : With light/surge voltage suppressor Manual override (Non-locking) (With direct manual override: 0) 00 (Lead wire length) Max. 0 (With direct manual override:.) -Rc /8, / pplicable cable O.D. ø6 to ø8 : With light/surge voltage suppressor -ø.6 (Mounting hole) Max. 0 (With direct manual override:.6) (External pilot port) ( ): Rc / pplicable cable O.D. ø. to ø7 : With light/surge voltage suppressor VP S S VS N --

37 Series Non Plug-in position double, position closed center/exhaust center/pressure center 0 position double: -G position closed center: -G position exhaust center: -G position pressure center: -G Rc /8 (PE port) (With direct manual override: 0) Manual override (Non-locking) E: Grommet terminal T: Conduit terminal D, Y: DIN terminal pplicable cable O.D. ø. to ø.8 [ ]: position : With light/surge voltage suppressor 00 (Lead wire length) (With direct manual override: 0) Max. 0 -Rc /8, / (With direct manual override:.) pplicable cable O.D. ø6 to ø8 [ ]: position : With light/surge voltage suppressor -ø.6 (Mounting hole) Max. 0 (With direct manual override:.6) (External pilot port) [ ]: position ( ): Rc / pplicable cable O.D. ø. to ø7 [ ]: position : With light/surge voltage suppressor --6

38 7 Series 000 Manifold Specifications Manifold Specifications ase mounted V-0 Non plug-in type V-0 Non plug-in type V-0 Wiring With terminal block With multi-connector With D-sub connector Grommet terminal DIN terminal Grommet Grommet terminal Conduit terminal DIN terminal Since lead wires of solenoid valve are connected with the terminals on upper surface of terminal block, corresponding lead wires from power source can be wired at the bottom of terminal block. Porting specifications, port Side/ottom V Series 000 Manifold with terminal block 0 stations 0 V Port size P, E, E, Note) 0T 0 stations 0C Series 000 Manifold with multi-connector Connector mounting 0 stations direction D D side mounting 08 8 stations U U side mounting Max: 8 stations, 8 C8, C0 Note) If silencer is mounted to E/E port, use silencer N0-0 (O.D. ø7). How to Order Manifold ssembly <Example> with terminal block: 6 stations V-0T-06-0 set (Manifold base part no.) 00-FZ sets ( position single part no.) 00-FZ sets ( position double part no.) VS000-0 set (lanking plate) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Valve arrangement is counted from the D side. When ordering, specify the part nos. in order from the st. station in the D side. When entry of part numbers becomes complicated, indicate on the manifold specification sheet. Plug-in Type: With Terminal lock U side Terminal block (Internal) D side 06 0 Passage Porting P E, E specifications (, ) Side Common Common ottom Option D 0 0 to 0 to 8 to 0 Passage Porting P E, E specifications (, ) Side Common Common ottom Option pplicable valve model 00-F -E -D -G -E -T -D <Example> Non plug-in type: 6 stations Plug-in Type: With Multi-connector (For wiring specifications, refer to page --8.) U side Conduit wiring Master connection of power and solenoid valves. Quick wiring permits ease of installation. D side V set (Manifold base part no.) 0-D sets ( position single part no.) 0-D set ( position exhaust center part no.) V000-R-0- set (Individual EXH spacer part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Valve arrangement is counted from the D side. When ordering, specify the part nos. in order from the st. station in the D side. When entry of part numbers becomes complicated, indicate on the manifold specification sheet. Port size P, E, E 0 0, 8 C8 One-touch fitting for ø8 C0 One-touch fitting for ø0 M Mixed For bottom ported: Rc /, /8 only. Port size P, E, E 0 0, 8 C8 One-touch fitting for ø8 C0 M One-touch fitting for ø0 Mixed For bottom ported: Rc /, /8 only. Thread type Nil Rc F G N NPT T NPTF Thread type Nil Rc F G N NPT T NPTF VP S S VS N Multi-connector --7

39 Series Plug-in Type: With D-sub Connector (For wiring specifications, refer to page --8.) Wide range of interchangeability ( pin D-sub connector conforms to V MIL standard) Quick wiring permits easier installation. Series 000 Manifold with U side D-sub connector Connector mounting 0 stations direction D side D U D side mounting U side mounting 0F 08 8 stations Max: 8 stations D 06 0 Port size P, E, E 0 0 Passage Porting C8 specifications P E, E (, ) C0 Side Common Common ottom Option M, 8 One-touch fitting for ø8 One-touch fitting for ø0 Mixed For bottom ported: Rc /, /8 only. Thread type Nil Rc F G N NPT T NPTF D-sub connector Non Plug-in Type: Grommet Terminal, DIN Terminal (Common electrical entry) Individual wiring for every valve Grommet terminal DIN terminal V Non Plug-in Type: Grommet, Grommet Terminal, Conduit Terminal, DIN Terminal (Individual electrical entry) Individual wiring for every valve Note) Manifold base is in common with Series S Series 000 Manifold Non plug-in type Common electrical entry 0 stations 0 V 0 stations 0 Series 000 Manifold Non plug-in type Individual electrical entry 0 stations 0 0 stations 0 0 Port size P, E, E 0 Passage Porting 0 C8 specifications P E, E (, ) C0 Side Common Common ottom Option 0 0 Passage Porting P E, E specifications (, ) Side Common Common ottom Option M, 8 One-touch fitting for ø8 One-touch fitting for ø0 Mixed For bottom ported: Rc /, /8 only. Port size P, E, E, C8 One-touch fitting for ø8 C0 One-touch fitting for ø0 M Mixed For bottom ported: Rc /, /8 only. Thread type Nil Rc F G N NPT T NPTF Note) Manifold base is in common with V-0. Thread type Nil Rc F G N NPT T NPTF --8

40 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series Manifold/Option Parts ssembly Individual SUP spacer Setting individual SUP spacer on the manifold block enables individual SUP port for each valve. ody type Non plug-in type Part no. VS000-P-0- VS000-P-0- Throttle valve spacer Needle valve set on the manifold block can control cylinder speed by throttling exhaust. ody type Non plug-in type Part no. VS VS Shape Manifold Option With exhaust cleaner /Non plug-in type Valve exhaust noise dampening: d or more. Collects oil mist: collecting rate 99.9% or more Piping process reduced. Individual EXH spacer Setting individual EXH spacer on the manifold block enables individual EXH port for each valve. ody type Non plug-in type Part no. VS000-R-0- VS000-R-0- SUP block disk When supplying manifold with more than two different pressures, high and low, insert a block disk in between stations subjected to different pressures. ody type Non plug-in type Part no. XT66- EXH block disk When valve exhaust affects the other stations on the circuit, insert EXH block disk in between stations to separate valve exhaust. ody type Non plug-in type Part no. XT66- Interface regulator Interface regulator set on the manifold block can regulate pressure for each valve. (Refer to Flow Characteristics on page - -6 before operation.) ody type Non plug-in type P port regulation RF00-00-P- RF00-00-P- port regulation RF RF port regulation RF RF SUP stop valve spacer If SUP stop valve spacer is set, valve can be removed for maintenance without stopping air pressure supply for other valves. ody type Non plug-in type Part no. VS VS (Height will be 7. mm higher.) lanking plate It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. ody type Non plug-in type Part no. VS000-0 Mounting screws: positions For details, refer to page --. With control unit /Non plug-in type Filter, regulation valve, pressure switch and air release valve are all combined to form one unit. Piping processes are eliminated. For details, refer to page --. With serial interface unit for serial transmission Solenoid valve wiring process reduced considerably. Disperse installation possible. Manifold solenoid valve: 8 stations max. positions ( solenoids). Maintenance and inspection are easy. For details, refer to Serial Transmission catalog separately. VP S S VS N --9

41 Series Manifold With terminal block: V-0T- Station - Port size n-rc /, /8 (, port) Light/Surge voltage suppressor Manual override (Non-locking) U side n-rc /8, /, C8, C0 (, port) (Pitch) P = P = (Pitch) Max. L L ottom ported: V-0T- Station - Port size L L L L n: Station Formula L = x n + 6 L = x n + 7 n: Station Formula L = x n + 6 L = x n + 7 With multi-connector: V-0CD- Station - Port size, V-0CU- Station - Port size n-rc /, /8 (, port) (Pitch) P = Plug assembly: VS (Option: Refer to page --8.) (With direct manual override:.) -Rc /8 (PE port) -G / (Electrical entry) Light/Surge voltage suppressor Manual override (Non-locking) (With direct manual override:.) -Rc /8 (PE port) U side D side D side 6-Rc / (P, E, E port) 6-Rc / (P, E, E port) C8, C0 n-rc /8, /, C8, C0 C8, C0 P = (Pitch) C8: Max. 6. C0: Max. 7 C8: Max. 6. C0: Max

42 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series 000 Manifold With D-sub connector: V-0FD- Station - Port size, V-0FU- Station - Port size L L L L For wiring specifications, refer to page --8. n: Station Formula L = x n + 6 L = x n + 7 ottom ported: V-0- Station - Port size C8, C0 L L (Pitch) P = Manifold 9 n-rc /, /8 (, port) 6 7 Non plug-in type V-0- Station - Port size n-rc /, /8 (, port) (Pitch) P = Max (With direct manual override:.) (With direct manual override: 7) Manual override (Non-locking) (With direct manual override: 6) Manual override (Non-locking) Plug assembly: VS000-- (Option: Refer to page --8.) C8: Max. 6. C0: Max. 7 -Rc /8 (PE port) pplicable cable O.D. ø8 to ø0 -Rc /8 (PE port) Max. 0 n: Station Formula L = x n + 6 L = x n + 7 Light/Surge voltage suppressor U side D side n-rc /8, /, C8, C0 (, port) 6-Rc / (P, E, E port) U side D side 6-Rc / (P, E, E port) P = (Pitch) n-rc /8, / C8, C0 (, port) C8, C0 P = (Pitch) Grommet with terminal C8: Max. 6. C0: Max. 7 (With direct manual override:.) VP S S VS N --

43 Series 000 Manifold V-0- Station - Port size G: Grommet U side n-rc /8, / (, port) Manual override (Non-locking) (Pitch) P = (Pitch) P = [ ]: With direct manual override E: Grommet terminal T: Conduit terminal D, Y: DIN terminal pplicable cable O.D. ø. to ø.8 00 (Lead wire length) -Rc /8 (PE port) L L L pplicable cable O.D. ø6 to ø D side 6-Rc / (P, E, E port) pplicable cable O.D. ø. to ø7 n: Station Formula L = x n + 6 L = x n + 7 : With light/surge voltage suppressor : With light/surge voltage suppressor : With light/surge voltage suppressor Max. 0 Max. 0 --

44 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series 000 Manifold/Option Parts ssembly Individual SUP spacer: VS000-P-0- () VS000-P-0- (Non plug-in type) /Non plug-in type Interface regulator/p port regulation: RF00-00-P- () RF00-00-P- (Non plug-in type) (With direct manual override: 60) Individual EXH spacer: VS000-R-0- () VS000-R-0- (Non plug-in type) (With direct manual override: 60) SUP/EXH block disk: XT66- Note) Used with exclusive manifold block Throttle valve spacer: VS () VS (Non plug-in type) (With direct manual override: 60) Individual SUP spacer Individual EXH spacer Throttle valve spacer Rc /8 Rc /8 lock disk mounting position (With direct manual override: 7) Interface regulator Interface regulator/ port regulation: RF () RF (Non plug-in type) (With direct manual override: 7) Interface regulator Interface regulator/ port regulation: RF () RF (Non plug-in type) (With direct manual override: 7) Interface regulator VP S S VS N --

45 Series 000 Manifold with Exhaust Cleaner Serves to protect working environment. Valve exhaust noise dampening: d or more. Collection rate of drainage and oil mist: 99.9% or more Piping work is reduced. Manifold Specifications Manifold Wiring pplicable valve model Porting specifications Rc pplicable exhaust cleaners : V-0 Non plug-in type: V-0 Non plug-in type: V-0 With terminal block DIN terminal Grommet, Grommet terminal With multi-connector Grommet terminal Conduit terminal, DIN terminal With D-sub connector 0-F -D -E -G, -E -T, -D Common SUP, Common EXH, port Side: Rc /, /8, C8, C0 ottom: Rc /, /8 (Option) P port Side: Rc / EXH port: Rc to 0 stations (With multi-connector/d-sub connector: to 8 stations) MC60-0 (Port size: R) Note) Note) Exhaust cleaner MC60-0 is not included. U side Non plug-in type Exhaust cleaner MC60-0 (Option) D side Exhaust cleaner MC60-0 (Option) How to Order Manifold ssembly <Example> with terminal block (6 stations) V Series 000 Manifold 0T 0C 0F V-0T-06-0-CD set (Manifold base part no.) 00-FZ sets ( position single part no.) 00-FZ sets ( position double part no.) VS000-0 set (lanking plate assembly part no.) MC60-0 set (Exhaust cleaner part no.) 0 0 ase type/ Electrical entry with terminal block with multi-connector with D-sub connector Non plug-in type Common electrical entry Non plug-in type Individual electrical entry The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Valve arrangement is counted from the D side. When ordering, specify the part nos. in order from the st. station in the D side. When entry of part numbers becomes complicated, indicate on the manifold specification sheet. Caution When using an exhaust cleaner, mount it downwards CD Connector mounting direction With connector pplicable base Nil None 0T, 0, 0 D D side mounting 0C, 0F U U side mounting 0 stations 0 Note) 0 stations Note) ase 0T/0/0: to 0 stations ase 0C/0F: to 8 stations How to Order Exhaust cleaner mounting direction Exhaust cleaner mounting direction CD D side D side mounting CU U side U side mounting Thread type Nil Rc F G N NPT T NPTF Port size P, E, E, One-touch C8 fitting for ø8 One-touch C0 fitting for ø0 M Mixed For bottom ported: Rc /, /8 Passage Porting P E, E specifications (, ) Side Common Common ottom Option <Example> Non plug-in type: 6 stations V CU set (Manifold base part no.) 0-E sets ( position single part no.) 0-E sets ( position double part no.) VS000-0 set (lanking plate assembly part no.) MC60-0 set (Exhaust cleaner part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Valve arrangement is counted from the D side. When ordering, specify the part nos. in order from the st. station in the D side. When entry of part numbers becomes complicated, indicate on the manifold specification sheet. Refer to est Pneumatics Vol. for Exhaust Cleaner details. --

46 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series 000 Manifold with Exhaust Cleaner /Non plug-in type : V-0T- Station - Port size - CD CU U side Pilot valve manual override [ ]: With direct manual override [ ]: With direct manual override D side Non plug-in type: V-0- Station - Port size - CD CU Light -Rc /8 (Pilot EXH port: PE) -G / Electrical entry -Rc /8 (Pilot EXH port: PE) Light -Rc /8 (External pilot port: X) 6-Rc / U side D side n-rc /, /8, C8, C0 Pilot valve manual override Exhaust cleaner (Option) Exhaust cleaner (Option) n-rc /, /8, C8, C0 Pilot valve manual override -Rc /8 (External pilot port: X) 6-Rc / L L L D side mounting D side mounting P = (Pitch) P = (Pitch) D side U side D side U side U side mounting U side mounting n: Station Formula L = x n + 6 L = x n + 7 VP S S VS N --

47 Series Manifold with Exhaust Cleaner Non plug-in type Non plug-in type: V-0- Station - Port size - CD CU (Lead wire length) 00 U side Manual override (Non-locking) n-rc /8, /, C8, C0 (, port) D side -Rc /8 (PE port) [ ]: With direct manual override (Pitch) P = D side Exhaust cleaner (Option) -Rc /8 (X port) 6-Rc / L L L (Pitch) P = Manual override (Non-locking) U side U side mounting Exhaust cleaner (Option) n: Station Formula L = x n + 6 L = x n

48 Manifold with Control Unit Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series Control unit (Filter, Regulator, Pressure switch, ir release valve) are all standardized to the one unit, and can be mounted on the manifold base without any attachments. Piping processes are eliminated. U side Non plug-in type D side Caution ir filter with auto-drain or manual drain must be mounted with the air filter at the bottom. Manifold Specifications Manifold Wiring pplicable valve model Porting specifications Rc : V-0 Non plug-in type: V-0 Non plug-in type: V-0 With terminal block DIN terminal Grommet, Grommet terminal With multi-connector Grommet terminal Conduit terminal, DIN terminal With D-sub connector 0-F Control Unit Specifications -D -E Control Unit/Option -G, -E -T, - Common SUP, Common EXH, port Side: Rc /, /8, C8, C0 ottom: Rc /, /8 (Option) P, E, E port Side: Rc / to 0 (With multi-connector/d-sub connector: to 8) Including station of control unit ir filter (With auto-drain/with manual drain) Filtration degree µm Regulator Set pressure 0.0 to 0.8 MPa (Outlet pressure) Pressure switch Set pressure range: OFF 0. to 0.6 MPa Differential 0.08 MPa Contact a Indicator light LED (RED) Max. switch capacity V C, W DC Max. operating VC, DC or less: 0 m current 00 VC, DC: 0 m Inside voltage drop V or less ir release valve (Single only) Operating 0. to 0.9 MPa pressure range () ir release valve spacer <> VS000--R (D side mounting) <Non plug-in type> VS000--R (D side mounting) Pressure () IS000P-- switch For filter regulator MP- lanking For pressure switch MP- plate For air release valve VS Filter IN--8-- element Note ) Combining valve (single) and release valve spacer makes it possible to use this as an air release valve. Note ) Pressure switch cannot be mounted later on non plug-in type. D Y VP S S VS N --7

49 Series V 0 Series 000 Manifold ase type/electrical entry 0T 0C 0F 0 0 Plug-in with terminal block Plug-in with multi-connector with D-sub connector Non plug-in type (Common entry) Non plug-in type (Individual entry) Connector mounting direction With connector pplicable base Nil None 0T, 0, 0 D D side mounting 0C, 0F U U side mounting 0 stations 0 Note) 08 0 P 0 stations Note) ase 0T/0/0: to 0 stations ase 0C/0F: to 8 stations Including stations of control unit. How to Order Manifold ssembly <Example> with terminal block Passage Porting specifications P E, E (, ) Side Common Common ottom Option Port size P, E, E 0 0, 8 C8 One-touch fitting for ø8 C0 One-touch fitting for ø0 M Mixed For bottom ported: only /, /8 V-0T-08-0-P set (Manifold base part no.) 00-FZ sets ( position single part no.) 00-FZ sets ( position double part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. The st and nd station are used for control unit mounting. When ordering, specify the part nos. in order from the rd. station in the D side. When entry of part numbers becomes complicated, indicate on the manifold specification sheet. How to Order Control unit type ir release valve coil rating Nil 9 None 00 VC, 0/60 Hz VDC Other Control equipment Nil MP P M G F C E ir release valve ir filter regulator with manual drain ir filter regulator with auto-drain Pressure switch lanking plate (ir release valve) lanking plate (Filter regulator) lanking plate (Pressure switch) Required stations stations station Thread type Nil F N T Note) Control unit is D side mounting only. Rc G NPT NPTF <Example> Non plug-in type V set (Manifold base part no.) 0-D sets ( position single part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. The st and nd station are used for control unit mounting. When ordering, specify the part nos. in order from the rd. station in the D side. When entry of part numbers becomes complicated, indicate on the manifold specification sheet. --8

50 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series Manifold with Control Unit /Non plug-in type : V-0T- Station - Port size -P Voltage of air release valve Example for manifold Individual EXH spacer -Rc /8 (Pilot EXH port: PE) -G / Electrical entry [ ]: With direct manual override 6-Rc / U side D side U side D side [ ]: With direct manual override Non plug-in type: V-0- Station - Port size -P Voltage of air release valve Pressure switch ir release valve -Rc /8 (Pilot EXH port: PE) Light Pressure switch ir release valve (90: -MP) Light (90: -MP) n-rc /, /8, C8, C0 Pilot valve manual override Rc / (Po port) -Rc /8 (External pilot port: X) n-rc /, /8, C8, C0 Pilot valve manual override Rc / (Po port) -Rc /8 (External pilot port: X) L L L L (MP) L (P) P = (Pitch) P = (Pitch) Example for manifold Individual SUP spacer Control unit Pressure switch ir release valve Filter regulator Individual EXH spacer Individual SUP spacer Pressure switch ir release valve Filter regulator Control unit 9 6. n: Station Formula L = x n + 6 L = x n + 7 L = x n + 6 L = x n VP S S VS N

51 Series Manifold with Control Unit Non plug-in type Non plug-in type: V-0- Station - Port size -P Voltage of air release valve (Lead wire length) 00 U side Manual override (Non-locking) n-rc /8, /, C8, C0 (, port) [ ]: With direct manual override -Rc /8 (PE port) Pressure switch ir release valve D side 6-Rc / ( ): MP Rc / (Po port) -Rc /8 (External pilot port) (Pitch) P = n: Station L Formula L L L = x n + 6 L = x n + 7 L (MP) 6 L (P) L = x n + 6 L = x n + 8. (0: -MP) --0

52 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series 000 Manifold ase Construction /Non plug-in type End plate (D side) Replacement Parts No. Description Material Part no. q w e Connection fitting Connection fitting Gasket Steel Steel NR VS000-- VS000-- VS r Gasket NR VS000-8 t O-ring NR 9.8 x 6.6 x.6 (for end plate) y O-ring NR 0 x 6 x (for manifold block) u O-ring NR 6. x x.6 i Terminal assembly VS000-6 o Junction cover assembly For 0T VS000-- For 0SU Z78--! Rubber plug NR XT6-9 Replacement Parts: Sub ssembly No.!0!! Description Manifold block assembly Note) End plate (U side) assembly End plate (D side) assembly Note) For side ported End plate (U side) ssembly part no. VS VS VS000-- VS000-- VS000-- VS C8 C0 0 0 C8 C0 Note) Manifold ase/construction: with terminal block. Component parts Manifold block!0, Terminal i, Connection bracket q, w, Gasket e, r, O-ring y, u, Receptacle assembly Manifold block o, Connection bracket q, w, Gasket e, r, O-ring y, u End plate (U)!, Connection bracket q, w, Gasket r, O-ring t, u End plate (U)!, Connection bracket q, w, Gasket r, O-ring t, u End plate (D)!, Connection bracket q, w, Gasket e End plate (D)!, Connection bracket q, w, Gasket e pplicable manifold base Non plug-in type Non plug-in type Non plug-in type -- VP S S VS N

53 --

54 For details about certified products conforming to international standards, visit us at Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series 000 JIS Model Type of actuation position position Single Plug-in 0 Double 0 Closed center 0 Exhaust center 0 Pressure center 0 Non plug-in type position position Single Closed center Double Exhaust center Pressure center Model Non plug-in 0 0 Port () size Standard Specifications Valve specifications Electricity specifications Option Specifications C [dm /(s bar)] 0 0 Fluid Operating pressure range mbient and fluid temperature Lubrication Manual override Mounting orientation Shock/Vibration resistance Enclosure Coil rated voltage llowable voltage fluctuation Inrush pparent power (C) () Holding Power consumption (DC) () Electrical entry Flow characteristics () / (P /) / / (/ E/E) b 0.0 position single/ position position double 0 0 Cv C [dm /(s bar)] b Cv [] 0. [0.0].6 [.] [] 0. [0.0].6 [.] [.0] 0.7 [0.]. [.] 0.8. [.] 0. [0.].7 [.] 0.8. ir 0. to 0.9 MPa 0. to 0.9 MPa 0 to 0 C (No freezing. Refer to page --.) Non-lube () Non-locking push type Unrestricted 00/0 m/s () Dustproof 00, 00 VC (0/60 Hz), VDC to 0% of rated voltage.6 V/0 Hz,.0 V/60 Hz. V (. W)/0 Hz,. V (. W)/60 Hz.8 W Conduit terminal Grommet, Grommet terminal Non plug-in type Conduit terminal, DIN terminal Note ) t rated voltage Note ) Use turbine oil Class (ISO VG), if lubricated. Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Pilot type Manual Main valve External pilot Note) Direct manual override override Pilot valve Non-locking push type (Extended), Locking type (Tool required), Locking type C (Lever) Coil rated voltage 0 to 0, 0, 0 VC 0/60 Hz, 00 VDC Porting specifications ottom ported Option With light/surge voltage suppressor Note) Operating pressure: position 0 to 0.9 MPa Pilot pressure: position single 0. to 0.9 MPa position 0. to 0.9 MPa position double 0. to 0.9 MPa position 0. x P + 0. to 0.9 MPa (P: Operating pressure) Max. operating cycle (Hz) () Response time (ms) 0 or less 0 or less 0 or less 70 or less 70 or less Note ) E, E port: Rc /8 Note ) [ ]: Normal position Note ) Min. operating frequency is once in 0 days. (ased on JIS 87) Note ) ased on dynamic performance test, JIS (0. MPa, Coil temperature: 0 C, at rated voltage, without surge voltage suppressor) Note ) For 00-FZ-, ( ): 0- DZ-, < >: 0-G- () () Weight (kg).0 (.0) <.0>.0 (.6) <.6>.0 (.6) <.6>.0 (.6) <.6>.0 (.6) <.6> VP S S VS N --

55 Series 000 F:, conduit type Electrical entry Option Nil Z None With light/surge voltage suppressor Porting specifications (P,, E, E port) Nil How to Order Side ported ottom ported Option. no bottom piping for external pilot. Port size (P, and port) Nil 0 0 Without sub-plate 8 E, E port: Rc /8 Thread type Nil Rc F G N NPT T NPTF Plug-in 0 0 F 0 Non plug-in D 0 Common electrical entry Non plug-in 0 G 0 position single position double position closed center position exhaust center position pressure center SF F 70 Coil rated voltage Electrical entry, Light/Surge voltage suppressor Manual override Rated voltage 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 to 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC 6 VDC 7 0 VC, 0/60 Hz 9 Other Option ody option 0 Standard Direct manual override Option Pilot type Nil R Option 6 7 F G GS E EZ T TZ D DZ Y YZ Internal pilot External pilot Coil rated voltage 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 V to 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC VDC 0 VC, 0/60 Hz 9 Other Option G: Grommet E: Grommet terminal How to Order Pilot Valve ssembly Electrical entry Plug-in Grommet Grommet terminal Conduit terminal DIN terminal DIN terminal (DIN60 type) Indicator light With surge voltage suppressor Option: Nil Z Nil Z S pplicable valve model 0 None With light/surge voltage suppressor Option: None With light/surge voltage suppressor With surge voltage suppressor Indicator light (Z) is not available for grommet type. Surge voltage suppressor (S) is available only on grommet. Electrical entry: E: Grommet terminal D: DIN terminal Electrical entry: T: Conduit terminal D, Y: DIN terminal Nil C Option Non-locking push type Non-locking push type (Extended) Locking type (Tool required) Locking type C (Lever) Individual electrical entry Pilot valve Manual override Nil: Non-locking push type : Non-locking push type (Extended) : Locking type (Tool required) C : Locking type C (Lever) Option pplicable valve model 0 Nil 0, : Pilot valve assembly is all plugin (F). --

56 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series 000 Cylinder Speed Chart System Solenoid valve C System Series 000 Rc / 8 Series 000 Rc / 8 Series 000 Rc / verage speed (mm/s) C It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. Load factor: ((Load weight x 9.8)/Theoretical force) x 00% System Components Speed controller S000-0 (S = mm ) S0-0 (S = 7 mm ) S0-0 (S = 97 mm ) Use as a guide for selection. Please confirm the actual conditions with SMC Sizing Program. ore size Series M Pressure 0. MPa Load factor 0% Stroke 00 mm Series CS Pressure 0. MPa Load factor 0% Stroke 000 mm ø0 ø6 ø80 ø00 ø ø0 ø60 ø80 ø00 ø0 ø00 Silencer N00-0 (S = 60 mm ) N00-0 (S = 60 mm ) N00-0 (S = 90 mm ) How to Order Sub-plate ssembly SPG (Steel pipe) dia. x Length 0 x m 0 x m x m Pilot type Nil Internal pilot <Side ported> R External pilot Plug-in 000 P 0 Thread type Nil Rc Non plug-in S000 S 0 F G <ottom ported> N NPT Plug-in 000 P 0 T NPTF Non plug-in S000 S 0 Note) ottom ported is not available for external pilot. Mounting bolts and gaskets are not included. Piping port (P,, port) E, E port 8 Perpendicular, upward actuation Horizontal actuation VP S S VS N --

57 Series Construction position single position double 0 0 Component Parts No. q w e r Replacement Parts No. o!0! Description ody Sub-plate Spool valve dapter plate Closed center: 0 Exhaust center: 0 Pressure center: 0 Description Gasket Hexagon socket head screw Pilot valve assembly Sub-plate assembly position closed center/exhaust center/pressure center Material luminum die-casted luminum die-casted luminum, NR Resin Material NR Steel (leed) Note Platinum silver Platinum silver lack XT--(M x 0) No. t y u i Description End plate Junction cover Light cover Spool spring This figure shows a closed center type. Material Resin Resin Resin Stainless steel Part no XT--(M x 0) Refer to How to Order Pilot Valve ssembly on page --. Refer to How to Order Sub-plate ssembly on page --. Note lack // XT--(M x 0) --6

58 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series Plug-in position single/double, position closed center/exhaust center/pressure center 0 position single: 0 -F -ø. (Electrical entry) Manual override (Non-locking) G / 0 -Rc /8 (E, E port) position double: 0 -F position closed center: 0 -F position exhaust center: 0 0 -F 0 position pressure center: 0 -F -ø. (Electrical entry) G / Manual override (Non-locking) -Rc /8, / (P,, port) -Rc /8, / (E, E: Rc /8) -ø6. (Mounting hole) Light/Surge voltage suppressor 0 -ø6. (Mounting hole) Rc /8 (PE port) Rc /8 (PE port) -ø6. mounting hole Other dimensions are the same as the single type. VP S S VS N --7

59 Series Non Plug-in position single/double, position closed center/exhaust center/pressure center position single: -E, -D 0 0 -ø6. mounting hole -Rc /8, / (E, E: Rc /8) Rc /8 (PE port) Manual override (Non-locking) pplicable cable O.D. ø8 to ø0 0 0 position double: -E, -D position closed center: -E, -D 0 0 position exhaust center: -E, -D 0 0 position pressure center: -E, -D Rc /8 (PE port) pplicable cable O.D. ø8 to ø0 Manual override (Non-locking) G / -Rc /8, / (P,, port) DIN terminal -ø6. (Mounting hole) -Rc /8 (E, E port) -ø6. (Mounting hole) Grommet terminal 0 Rc /8 (leed port) Other dimensions are the same as the single type. Rc /8 (PE port) 0 --8

60 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series Non Plug-in position single 0 position single: -G Rc /8 (PE port) E: Grommet terminal T: Conduit terminal D, Y: DIN terminal pplicable cable O.D. ø. to ø.8 : With light/surge voltage suppressor Manual override (Non-locking) 00 (Lead wire length) -ø6. (Mounting hole) -Rc /8 (E, E port) -Rc /8, / (P,, port) pplicable cable O.D. ø6 to ø8 : With light/surge voltage suppressor Max. 0 Max. 0 Rc /8 (leed port) pplicable cable O.D. ø. to ø7 : With light/surge voltage suppressor VP S S VS N --9

61 Series Non Plug-in position double, position closed center/exhaust center/pressure center 0 0 position double: -G position closed center: -G 0 position exhaust center: -G 0 position pressure center: -G Rc /8 (PE port) E: Grommet terminal T: Conduit terminal D: DIN terminal pplicable cable O.D. ø. to ø.8 Manual override (Non-locking) : With light/surge voltage suppressor 00 (Lead wire length) -ø6. (Mounting hole) -Rc /8 (E, E port) pplicable cable O.D. ø6 to ø8 : With light/surge voltage suppressor Max. 0 -Rc /8, / (P,, port) Max. 0 pplicable cable O.D. ø. to ø7 Rc /8 (PE port) : With light/surge voltage suppressor --60

62 6 Series 000 Manifold Specifications Manifold Specifications ase model V-0 Non plug-in type V-0 Non plug-in type V-0 Wiring With terminal block With multi-connector With D-sub connector Grommet terminal DIN terminal Grommet Grommet terminal Conduit terminal DIN terminal Since lead wires of solenoid valve are connected with the terminals on upper surface of terminal block corresponding lead wires from power source can be wired at the bottom of terminal block. Master connection of power and solenoid valves. Quick wiring permits ease of installation. Porting specifications, port Side/ottom How to Order Manifold ssembly <Example> with terminal block: 6 stations V-0T-06-0 set (Manifold base part no.) 00-FZ sets ( position single part no.) 00-FZ sets ( position double part no.) VS000-0 set (lanking plate assembly part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. V Port size P, E, E, 8, Valve arrangement is counted from the D side. When ordering, specify the part nos. in order from the st. station in the D side. When entry of part numbers becomes complicated, indicate on the manifold specification sheet. Plug-in Type: With Terminal lock Terminal block Series 000 Manifold with terminal block V Series 000 Manifold with multi-connector Connector mounting direction D D side mounting U U side mounting 0T to 0 to 8 to 0 0 stations 0 0C pplicable valve model 0-F -E -D -G -E -T -D <Example> Non plug-in type: 6 stations V set (Manifold base part no.) 0-D sets ( position single part no.) 0-D set ( position exhaust center part no.) V000-R-0- set (Individual EXH spacer part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Valve arrangement is counted from the D side. When ordering, specify the part nos. in order from the st. station in the D side. When entry of part numbers becomes complicated, indicate on the manifold specification sheet stations Plug-in Type: With Multi-connector (For wiring specifications, refer to page --8.) U side Multi-connector Conduit wiring D side Passage Porting P E, E specifications (, ) Side Common Common ottom Option D stations 08 8 stations Max: 8 stations Passage Porting P E, E specifications (, ) Side Common Common ottom Option Thread type Nil Rc F G N NPT T NPTF Port size P, E, E, 0 0 M 8 Mixed For bottom ported: Rc /8 only. Port size 0 0 M Nil F N T P, E, E Thread type Rc G NPT NPTF, 8 Mixed For bottom ported: Rc /8 only. VP S S VS N --6

63 Series Plug-in Type: With D-sub Connector (For wiring specifications, refer to page --8.) Wide range of interchangeability (D-sub connector (P) conforming V to MIL standard) Quick wiring permits easier installation. Series 000 Manifold with U side D-sub connector Connector mounting direction D side D U D side mounting U side mounting 0F D stations 08 8 stations Max: 8 stations Passage Porting specifications P E, E (, ) Side Common Common ottom Option Thread type Nil Rc F G N NPT T NPTF Port size P, E, E, M Mixed For bottom ported: Rc /8 only. D-sub connector Non Plug-in Type: Grommet Terminal, DIN Terminal (Common electrical entry) Individual wiring for every valve Grommet terminal DIN terminal Individual wiring for every valve V 0 Series 000 Manifold Non plug-in type Common electrical entry 0 stations V stations Series 000 Manifold Non plug-in type Individual electrical entry 0 stations 0 0 stations 0 0 Note) Manifold base is in common with V-0. Note) Manifold base is in common with Series S000 but the connection of terminal block for plug-in type is different. Thread type Nil Rc F G N NPT T NPTF Non Plug-in Type: Grommet, Grommet Terminal, Conduit Terminal, DIN Terminal (Individual electrical entry) Passage Porting P E, E specifications (, ) Side Common Common ottom Option Passage Porting P E, E specifications (, ) Side Common Common ottom Option Port size 0 0 M P, E, E, 8 Mixed For bottom ported: Rc /8 only. Port size 0 0 M Thread type Nil Rc F G N NPT T NPTF P, E, E, 8 Mixed For bottom ported: Rc /8 only. --6

64 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series Manifold/Option Parts ssembly Individual SUP spacer Setting individual SUP spacer on the manifold block enables individual SUP port for each valve. ody type Non plug-in type Part no. VS000-P-0- VS000-P-0- Throttle valve spacer Needle valve set on the manifold block can control cylinder speed by throttling exhaust. ody type Non plug-in type Part no. VS VS Manifold Option With exhaust cleaner Valve exhaust noise dampening: d or more. Collects oil mist: collecting rate 99.9% or more Piping process reduced. Individual EXH spacer Setting individual EXH spacer on the manifold block enables individual EXH port for each valve. ody type Non plug-in type Part no. VS000-R-0- VS000-R-0- SUP block disk When supplying manifold with more than two different pressures, high and low, insert a block disk in between stations subjected to plug-in different pressures. ody type Non plug-in type Part no. XT6-0 EXH block disk When valve exhaust affects the other stations on the circuit, insert EXH block disk in between stations to separate valve exhaust. ody type Non plug-in type Part no. XT6- EXH block disk SUP block disk Interface regulator Interface regulator set on the manifold block can regulate pressure for each valve. (Refer to Flow Characteristics on page --6 before operation.) ody type Non plug-in type P port regulation RF00-00-P- RF00-00-P- reduced pressure RF RF reduced pressure RF RF lanking plate It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. ody type Non plug-in type Part no. VS000-0 For details, refer to page With control unit /Non Filter, regulation valve, pressure switch and air release valve are all combined to form one unit. Piping processes are eliminated. For details, refer to page --7. With serial interface unit for serial transmission Solenoid valve wiring process reduced considerably. Disperse installation possible. Manifold solenoid valve: 8 stations max. positions ( solenoids). Maintenance and inspection are easy. For details, refer to Serial Transmission catalog separately. VP S S VS N --6

65 Series Manifold With terminal block: V-0T- Station - Port size Light/Surge voltage suppressor Manual override (Non-locking) U side n-rc /8 (, port) (Pitch) P = P = (Pitch) L L L L L L ottom ported: V-0T- Station - Port size n-rc /8 (, port) ottom ported: CD V-0 - Station - Port size CU For wiring specifications, refer to page --8. n: Station Formula L = x n + 70 L = x n + 8 n: Station Formula L = x n + 70 L = x n + 8 With multi-connector: V-0CD- Station - Port size, V-0CU- Station - Port size (Pitch) P = Max. Max. (+) Common terminal -Rc /8 (PE port) -G / (Electrical entry) Light/Surge voltage suppressor Plug assembly (Option: Refer to page --8.) -Rc /8 (PE port) U side D side D side n-rc /8, / (, port) External pilot port 6-Rc / (P, E, E port) n-rc /8, / (, port) External pilot port 6-Rc / (P, E, E port) Manual override (Non-locking) (Pitch) P = --6

66 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series Manifold With D-sub connector: V-0FD- Station - Port size, V-0FU- Station - Port size Light/Surge voltage suppressor U side Manual override (Non-locking) L L ottom ported: FD V-0 - Station - Port size L L L L For wiring specifications, refer to page Manifold 6 68 (Pitch) P = Max. FU n-rc /8 (, port) Non plug-in type V-0- Station - Port size (Pitch) P = Max. n-rc /8 (, port) ottom ported: V-0- Station - Port size 8 6 Plug assembly (Option: Refer to page --8.) n: Station Formula L = x n + 70 L = x n pplicable cable O.D. ø8 to ø0 Manual override (Non-locking) Rc /8 (PE port) n: Station Formula L = x n + 70 L = x n + 8 -Rc /8 (PE port) G / U side D side 6-Rc / (P, E, E port) External pilot port P = (Pitch) P = (Pitch) D side n-rc /8, / (, port) Grommet with terminal External pilot port 6-Rc / (P, E, E port) n-rc /8, / (, port) VP S S VS N --6

67 Series Manifold Non plug-in type V-0- Station - Port size U side Manual override (Non-locking) L L L n: Formula L = x n + 70 L = x n + 8 E: Grommet terminal T: Conduit terminal D, Y: DIN terminal pplicable cable O.D. ø. to ø.8 : With light/surge voltage suppressor 00 (Lead wire length) -Rc /8 (PE port) (Pitch) P = D side pplicable cable O.D. ø6 to ø8 (External pilot port) 6-Rc / (P, E, E port) : With light/surge voltage suppressor Max. 0 n-rc /8, / (, port) (Pitch) P = pplicable cable O.D. ø. to ø7 : With light/surge voltage suppressor Max

68 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series Manifold/Option Parts ssembly Individual SUP spacer: VS000-P-0- () VS000-P-0- (Non plug-in type) /Non plug-in type Interface regulator/p port regulation: RF00-00-P- () RF00-00-P- (Non plug-in type) Individual SUP spacer Rc /8 Interface regulator Individual EXH spacer: VS000-R-0- () VS000-R-0- (Non plug-in type) Individual EXH spacer SUP block disk: XT6-0 EXH block disk: XT6- Note) Used with exclusive manifold block ( ): EXH block disk Throttle valve spacer: VS () VS (Non plug-in type) Throttle valve spacer Rc / lock disk mounting position Interface regulator/ port regulation: RF () RF (Non plug-in type) Interface regulator Interface regulator/ port regulation: RF () RF (Non plug-in type) Interface regulator Dimensions: FZ type dimensions of direct manual style are also the same. VP S S VS N --67

69 Series Manifold with Exhaust Cleaner Serves to protect working environment. Valve exhaust noise dampening: d or more. Collection rate of drainage and oil mist: 99.9% or more. Piping work is reduced. Manifold Specifications Wiring Manifold pplicable valve model Porting specifications Rc pplicable exhaust cleaners : V-0 Non plug-in type: V-0 Non plug-in type: V-0 With terminal block DIN terminal Grommet, Grommet terminal, With multi-connector Grommet terminal Conduit terminal, DIN terminal With D-sub connector 0-F -D -E -G, -E -T, -D Common SUP, Common EXH Side: Rc / 8, / ottom: Rc / 8 (Option) Side: Rc / EXH Rc /, port P port to 0 stations (With multi-connector/d-sub connector: to 8 stations) MC60-0 (Port size: R ), MC80- (Port size: R /) Note) Note) Use MC80- when used with or more stations or in high frequency. Exhaust cleaner MC60-0 and MC80- are not attached. U side Non plug-in type Exhaust cleaner (Option) Exhaust cleaner (Option) D side How to Order Manifold ssembly V Series 000 Manifold 0T 0C 0F <Example> with terminal block (6 stations) V-0T-06-0-CD set (Manifold base part no.) 00-FZ sets ( position single part no.) 00-FZ sets ( position double part no.) VS000-0 set (lanking plate assembly part no.) MC60-0 set (Exhaust cleaner part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. 0 0 ase type/ Electrical entry with terminal block with multi-connector with D-sub connector Non plug-in type Common electrical entry Non plug-in type Individual electrical entry Valve arrangement is counted from the D side. When ordering, specify the part nos. in order from the st. station in the D side. When entry of part numbers becomes complicated, indicate on the manifold specification sheet. Caution When using an exhaust cleaner, mount it downwards. Connector mounting direction With connector pplicable base Nil None 0T, 0, 0 D D side mounting 0C, 0F U U side mounting 0 stations CD How to Order 0 Note) 0 stations Note) ase 0T/0/0: to 0 stations ase 0C/0F: to 8 stations Port size 0 0 P, E, E <Example> Non plug-in type: 6 stations V CU set (Manifold base part no.) 0-E sets ( position single part no.) 0-E sets ( position double part no.) Thread type Nil Rc F G N NPT T NPTF VS000-0 set (lanking plate assembly part no.) MC80- set (Exhaust cleaner part no.) Exhaust cleaner mounting direction Exhaust cleaner mounting direction CD D side D side mounting CU U side U side mounting Please indicate size or port size of exhaust cleaner., Refer to est Pneumatics Vol. for Exhaust Cleaner details. M 8 Mixed For bottom ported: Rc /8 only. Passage Porting P E, E specifications (, ) Side Common Common ottom Option The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Valve arrangement is counted from the D side. When ordering, specify the part nos. in order from the st. station in the D side. When entry of part numbers becomes complicated, indicate on the manifold specification sheet. --68

70 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series Manifold with Exhaust Cleaner /Non plug-in type : V-0T- - Port size - CD CU Pilot valve manual override ( ): MC80 ( ): MC80 -Rc /8 (Pilot EXH port: PE) -G / Electrical entry U side D side U side D side Non plug-in type: V-0- - Port size - CD CU 6. ( 60) -Rc /8 Pilot EXH port: PE 6 (60) R, / Exhaust cleaner (Option) R, / Exhaust cleaner (Option) n-rc /8, / -Rc /8 (External pilot port: X) -Rc / Pilot valve manual override n-rc /8, / -Rc /8 External pilot port: X -Rc / D side mounting D side mounting L L L 6 68 P = (Pitch) 99 P = (Pitch) D side Manual override U side U side mounting D side Manual override U side U side mounting n: Station Formula L = x n + 70 L = x n + 8 VP S S VS N --69

71 Series Manifold with Exhaust Cleaner Non plug-in type Non plug-in type: V-0- Station - Port size - CD CU U side Manual override (Non-locking) n-rc /8, / (, port) D side ( ): MC80 00 (Lead wire length) -Rc /8 (PE port) (Pitch) P = D side Exhaust cleaner (Option) -Rc /8 (External pilot port) -Rc / (P port) L L L (Pitch) P = Manual override (Non-locking) Exhaust cleaner (Option) U side U side mounting n: Station Formula L = x n + 70 L = x n

72 Manifold with Control Unit Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series Control unit (Filter, Regulator, Pressure switch, ir release valve) are all standardized to the one unit, and can be mounted on the manifold base without any attachments. Piping processes are eliminated. Manifold Specifications Wiring Manifold pplicable valve model : V-0 With terminal block With multi-connector With D-sub connector 0-F Non plug-in type: V-0 Non plug-in type: V-0 DIN terminal Grommet terminal -D -E Grommet, Grommet terminal, Conduit terminal, DIN terminal Common SUP, Common EXH Porting, port Side: Rc specifications / 8, /, ottom: Rc / 8 P, E, E port Side: Rc / to 0 (With multi-connector/d-sub connector: to 8) Including station of control unit -G, -E -T, -D Non plug-in type Caution ir filter with auto-drain or manual drain must be mounted with the air filter at the bottom. Control Unit Specifications ir filter (With auto-drain/with manual drain) Filtration degree µm Regulator Set pressure 0.0 to 0.8 MPa (Outlet pressure) Pressure switch Set pressure range: OFF 0. to 0.6 MPa Differential 0.08 MPa Contact a Indicator light LED (RED) Max. switch capacity Max. operating current V C, W DC VC, DC or less: 0 m 8 VC, DC: 0 m 00 VC, DC: 0 m Inside voltage drop V or less ir release valve (Single only) Operating 0. to 0.9 MPa pressure range Control Unit/Option () ir release valve spacer <> VS000--R (D side mounting) <Non plug-in type> VS000--R (D side mounting) Pressure () IS000P-- switch For filter regulator MP- lanking For pressure switch MP- plate For air release valve VS Filter 0- element Note ) Combining valve (single) and release valve spacer makes it possible to use this as an air release valve. Note ) Pressure switch cannot be mounted later on non plug-in type. VP S S VS N --7

73 Series V Series 000 Manifold ase type/electrical entry 0T 0C 0F 0 0 0C Plug-in with terminal block Plug-in with multi-connector with D-sub connector Non plug-in type (Common entry) Non plug-in type (Individual entry) Connector mounting direction With connector pplicable base Nil None 0T, 0, 0 D D side mounting 0C, 0F U U side mounting 0 stations D 08 0 P 0 0 <Example> with terminal block V-0T-08-0-P set (Manifold base part no.) 00-FZ sets ( position single part no.) 00-FZ sets ( position double part no.) M 8 Mixed For bottom ported: only /8 The st and nd station are used for control unit mounting. When ordering, specify the part nos. in order from the rd. station in the D side. When entry of part numbers becomes complicated, indicate on the manifold specification sheet. 0 Note) 0 stations Note) ase 0T/0/0: to 0 stations ase 0C/0F: to 8 stations Including stations of control unit. How to Order Passage Porting specifications P E, E (, ) Side Common Common ottom Option Port size P, E, E, How to Order Manifold ssembly The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Control unit type Control equipment Nil MP P M G F C E ir release valve ir filter regulator with manual drain ir filter regulator with auto-drain Pressure switch lanking plate (ir release valve) lanking plate (Filter regulator) lanking plate (Pressure switch) Required stations Thread type Nil F N T Rc G NPT NPTF <Example> Non plug-in type ir release valve coil rating Nil 9 None 00 VC, 0/60 Hz VDC Other Note) Control unit is D side mounting only. stations V set (Manifold base part no.) 0-D sets ( position single part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. station The st and nd station are used for control unit mounting. When ordering, specify the part nos. in order from the rd. station in the D side. When entry of part numbers becomes complicated, indicate on the manifold specification sheet. --7

74 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series Manifold with Control Unit /Non plug-in type : V-0T- - Port size -P Voltage of air release valve Example for manifold Pilot valve manual override -Rc /8 Pilot EXH port: PE -G / Electrical entry (80.: -MP) U side D side Non plug-in type: V-0- - Port size -P Voltage of air release valve (80.: -MP) -Rc /8 Pilot EXH port: PE 6-Rc / Pressure switch ir release valve Pressure switch ir release valve D side Pilot valve manual override n-rc /8, / Rc / (Po port) -Rc /8 (External pilot 6-Rc / port: X) U side n-rc /8, / Pilot valve manual override Rc / (Po port) -Rc /8 External pilot port: X P = (Pitch) P = (Pitch) Pressure switch ir release valve Filter regulator Example for manifold Individual EXH spacer Individual SUP spacer Control unit Individual EXH spacer Individual SUP spacer Control unit Pressure switch ir release valve Filter regulator n: Station L Formula L L L = x n + 70 L = x n + 8 L (MP) L = x n + 6. L (P) L = x n VP S S VS N

75 Series Manifold with Control Unit Non plug-in type Non plug-in type: V-0- - Port size -P Voltage of air release valve 00 (Lead wire length) U side R. n-rc /8, / (, port) Manual override (Non-locking) Pressure switch ir release valve -Rc /8 (PE port) D side 0 (8: -MP) 6-Rc / Rc / (Po port) -Rc /8 (External pilot port) (Pitch) P = n: Station L Formula L L L = x n + 70 L = x n + 8 L (MP) L = x n + 6. L (P) L = x n

76 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series Manifold ase Construction /Non plug-in type End plate (D side) Replacement Parts No. Description Material q Connection fitting Steel w e Connection fitting Gasket Steel NR r Gasket NR t Gasket NR y O-ring NR u O-ring NR i Terminal assembly o Junction cover assembly! Rubber plug NR Replacement Parts: Sub ssembly No.!0!! Description Manifold block assembly Note) End plate (U side) assembly End plate (D side) assembly Note) For side ported Part no. V000-- V000-- V000-7 (for end plate) V (for manifold block) V000-8 S68-0 P For 0T For 0SU ssembly part no V000-- V000-- V000-- V000-- End plate (U side) V000-- Z78-0- XT Manifold block Note) Manifold ase/construction: with terminal block. Component parts Manifold block!0, Terminal i, Connection bracket q, w, Gasket r, t, O-ring y, u, Receptacle assembly Manifold block!0, Connection bracket q, w, Gasket r, t, O-ring y, u End plate (U)!, Metal joint q, w End plate (U)!, Metal joint q, w End plate (D)!, Connection bracket q, w, Gasket e, r, O-ring y, u End plate (D)!, Connection bracket q, w, Gasket e, t, O-ring y, u pplicable manifold base Non plug-in type Non plug-in type Non plug-in type --7 VP S S VS N

77

78 For details about certified products conforming to international standards, visit us at 77 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series 000 (E)(P)(E) Double ()() (E)(P)(E) Non plug-in type JIS position position Single Closed center ()() ()() Model Type of actuation position position Single Double Closed center Exhaust center Pressure center Plug-in Model (E)(P)(E) Exhaust center () () (E)(P)(E) Pressure center ()() Non plug-in (E)(P)(E) Port size Standard Specifications Valve specifications Electricity specifications Fluid Operating pressure range mbient and fluid temperature Lubrication Manual override Mounting orientation Shock/Vibration resistance Enclosure Coil rated voltage llowable voltage fluctuation Inrush pparent power (C) () Holding Power consumption (DC) () Electrical entry Option Specifications position single/ position position double ir 0. to 0.9 MPa 0. to 0.9 MPa 0 to 0 C (No freezing. Refer to page --.) Non-lube () Non-locking push type Unrestricted 00/0 m/s () Dustproof 00, 00 VC (0/60 Hz), VDC to 0% of rated voltage.6 V/0 Hz,.0 V/60 Hz. V/0 Hz,. V/60 Hz Non plug-in type.8 W Conduit terminal Grommet terminal, DIN terminal Note ) Use turbine oil Class (ISO VG), if lubricated. Note ) t rated voltage Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Pilot type Manual override Main valve Pilot valve Coil rated voltage Porting specifications Option Note) Operating pressure: External pilot Note) Direct manual override Non-locking push type (Extended), Locking type (Tool required), Locking type C (Lever) 0 to 0, 0, 0 VC 0/60 Hz, 00 VDC ottom ported With light/surge voltage suppressor Pilot pressure: position 0 to 0.9 MPa position single 0. to 0.9 MPa position 0. to 0.9 MPa position double 0. to 0.9 MPa position 0. x P + 0. to 0.9 MPa (P: Operating pressure) Flow characteristics () Max. () Response () operating cycle time (Hz) (ms) / (P /) / / (/ E/E) C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv [6] 0.9 [0.].8 [.] [8] 0. [0.].6 [.0] [0] 0.7 [0.].9 [.] 6 [9.] 0.9 [0.0]. [.6] [9.7] 0. [0.].0 [.9] [9.] 0. [0.8]. [.8] Note ) [ ]: Denotes the normal position. Note ) Min. operating frequency is once in 0 days. (ased on JIS 87) Note ) ased on dynamic performance test, JIS (Coil temperature: 0 C, at rated voltage, without surge voltage suppressor) Note ) For 00-FZ-06, ( ): 0-DZ or less 60 or less 80 or less 80 or less 80 or less Weight () (kg).77 (.7).88 (.8).87 (.8).87 (.8).87 (.8) --77 VP S S VS N

79 Series How to Order F:, conduit type Electrical entry Plug-in 0 0 F Option Nil Z None With light/surge voltage suppressor Porting specifications Nil Side ported ottom ported In the case of external pilot (Option), bottom piping is not available. 06 Port size Nil Without sub-plate 8 Thread type Nil Rc F G N NPT T NPTF Non plug-in position single ()() (E)(P)(E) position double ()() (E)(P)(E) position closed center () () (E)(P)(E) position exhaust center () () (E)(P)(E) position pressure center ()() (E)(P)(E) ody option 0 Standard Direct manual override Option Pilot type Nil R Option 6 7 SF F 70 Coil rated voltage Rated voltage 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 to 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC 6 VDC 7 0 VC, 0/60 Hz 9 Other Option Internal pilot External pilot Coil rated voltage 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 to 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC VDC 0 VC, 0/60 Hz 9 Other Option How to Order Pilot Valve ssembly D Electrical entry E: Grommet terminal Manual override Nil Non-locking push type Non-locking push type (Extended) Locking type (Tool required) C Locking type C (Lever) Option 06 D: DIN terminal Pilot valve Manual override Nil: Non-locking push type : Non-locking push type (Extended) : Locking type (Tool required) C : Locking type C (Lever) Option --78

80 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series Cylinder Speed Chart Series Conditions 0-06 verage speed (mm/s) Tube x Length Speed controller Silencer How to Order Sub-plate ssembly <Side ported> Plug-in 000 P 06 Non plug-in S000 S 06 <ottom ported> Use as a guide for selection. Please confirm the actual conditions with SMC Sizing Program. ore size Series CS Pressure 0. MPa Load factor 0% Stroke 00 mm ø ø0 ø60 ø80 ø00 ø0 ø00 Plug-in 000 P 06 Non plug-in S000 S 06 Note) ottom ported is not available for external pilot. Mounting bolts and gaskets are not included. Series CS SGP0 x m S00-06 N00-06 Pilot type Nil R Internal pilot External pilot Piping port Thread type Nil F N T Perpendicular, upward actuation Horizontal actuation It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. Load factor: ((Load weight x 9.8)/Theoretical force) x 00% Rc G NPT NPTF 8 VP S S VS N --79

81 Series Construction 0 ()() position single position double 0 ()() (E)(P)(E) (E)(P)(E) r u q e t!0 r u q o e No. q w e r position closed center/exhaust center/pressure center Closed center: 0!0 r u q o e Exhaust center: 0 Pressure center: 0 Component Parts Description ody Sub-plate Spool valve dapter plate Replacement Parts No. i o! y () () Description (E)(P)(E) ()() (E)(P)(E) ()() (E)(P)(E) Gasket Hexagon socket head screw Pilot valve assembly PE (E) () (P) () (E) leed PE (E) () (P) () (E) PE Material luminum die-casted luminum die-casted luminum, NR Resin Material NR Steel Note Platinum silver Platinum silver lack i PE XT67-0- XT67--(M x 0) w (E) ()(P) () (E) PE This figure shows a closed center type. No. t y u Description End plate Junction cover Light cover i Material Resin Resin Resin Part no. XT67-0- XT67--(M x 0) Refer to How to Order Pilot Valve ssembly on page i Note lack lack // XT67-0- XT67--(M x 0)

82 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series Plug-in position single/double, position closed center/exhaust center/pressure center position single: 0 -F(Z) [] COM G / [] [9] 0 [0.] 7. [76.] [6.] 89. [87.] [9] [9] 6 [60] position double: 0 -F(Z) position closed center: 0 -F(Z) 0 position exhaust center: 0 -F(Z) 0 position pressure center: 0 -F(Z) [] COM -ø. (Electrical entry) Manual override (Non-locking) -ø. (Lead wire electrical entry) Manual override (Non-locking) G / 0 -Rc /8, /, / (Piping port) 0 E 6. [6.] [0] P E [] [] [] [] -ø7 (Mounting hole) 9 [0] [79] 6 [] 0 [9] 0. [9.] (For FZ) -ø7 7. [76.] (Mounting hole) 00 9 [0] E P [79] [6] -Rc /8, /, / E, E port = Rc / in case of Rc / Light/Surge voltage suppressor (For FZ) E Rc /8 External pilot port [For Rc /8, /] [6] [] [9] 0 [0.] Rc /8 External pilot port [For Rc /] Rc /8 E P E (PE port) 0 Other dimensions are the same as the single type. [ ] = Rc / X PE Rc /8 External pilot port [For Rc /8, /] [ ] = Rc / [] 8 X PE 6 [9.] 6 [9.] Rc /8 External pilot port [For Rc /] Rc /8 (PE port) [] 8 [] VP S S VS N --8

83 Series Non Plug-in position single/double, position closed center/exhaust center/pressure center position single: -E, -D(Z) 0 0 [] [9] 0 [0.] [6] [6] [] E P E 6 [9.] Light/Surge voltage suppressor (For DZ) [9.] [9] 0 [0.] -Rc /8, /, / E, E port = Rc / in case of Rc / 6 [0] 8 pplicable cable O.D. ø8 to ø0. [60.] 6. [7.] Manual override (Non-locking) [] [] [] [] 00 9 [0] [9] [9]. MX [79] position double: -E, -D(Z) position closed center: -E, -D(Z) 0 0 position exhaust center: -E, -D(Z) 0 0 position pressure center: -E, -D(Z) [0] 8 PE PE [] Rc /8 (PE port) Rc /8 (PE port) 0 -ø7 (Mounting hole) -Rc /8, /, / (Piping port) Manual override (Non-locking) G / 6 [60] [] [] 6 [] 09 6 [] 7. [.] 00 9 [0] E P E pplicable cable O.D. 6 [60] ø8 to ø0 -ø7. [60.] (Mounting hole) -ø. 6. [7.] (Lead wire electrical entry) E DIN terminal 0 P E 6 [60] -ø. Rc /8 External pilot port (Lead wire electrical entry) [For Rc /8, /] [] (Grommet terminal) [79] Rc /8 External pilot port [For Rc /] 0 Rc /8 (PE port) [ ] = Rc / Rc /8 External pilot port [For Rc /] Rc /8 (PE port) X PE 8 [] [] 8 Rc /8 External pilot port [For Rc /8, /] Other dimensions are the same as the single type. [ ] = Rc / X 0 PE --8

84 8 Series 000 Manifold Specifications Manifold Specifications ase model V-0 Non plug-in type V-0 Wiring With terminal block With multi-connector With D-sub connector Grommet terminal DIN terminal Porting specifications, port Side/ottom How to Order Manifold ssembly Port size Rc P, E, E,, to 0 to 8 to 0 pplicable valve model 0-F -E -D Instruct by specifying the valves, blanking plate and manifold option parts assembly to be mounted on the manifold along with the manifold base model no. <Example> with terminal block: 6 stations <Example> Non plug-in type: 6 stations V-0T-06-0 set (Manifold part number) 00-FZ sets ( position single) 00-FZ sets ( position double) VS000-0 set (lanking plate assembly part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Valve arrangement is counted from the D side. When ordering, specify the part nos. in order from the st. station in the D side. When entry of part numbers becomes complicated, indicate on the manifold specification sheet. Plug-in Type: With Terminal lock Since lead wires of solenoid valve are connected with the terminals on V upper surface of terminal block corresponding lead wires from Series 000 power source can be wired at the Manifold bottom of terminal block. with terminal block Plug-in Type: With Multi-connector (For wiring specifications, refer to page --8.) Master connection of power and solenoid valves. Quick wiring permits ease of installation. U side Terminal block Multi-connector Conduit porting Plug assembly (Option) D side Refer to page stations 0 stations V Series 000 Manifold Plug-in Type with multi-connector Connector mounting direction D D side mounting U U side mounting 0T 0C V set (Manifold part number) 0-D sets ( position single) 0-D set ( position exhaust center) VS000-R-0- set (Individual EXH spacer) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Valve arrangement is counted from the D side. When ordering, specify the part nos. in order from the st. station in the D side. When entry of part numbers becomes complicated, indicate on the manifold specification sheet Passage Porting P E, E specifications (, ) Side Common Common ottom Option Port size 0 06 M D stations 08 8 stations Max: 8 stations P, E, E Passage Porting P E, E specifications (, ) Side Common Common ottom Option, Mixed For bottom ported: / only. Nil F N T Thread type Nil Rc F G N NPT T NPTF Thread type Port size 0 06 M P, E, E Rc G NPT NPTF, Mixed For bottom ported: / only. --8 VP S S VS N

85 Series Plug-in Type: With D-sub Connector (For wiring specifications, refer to page --8.) Wide range of interchangeability (D-sub connector (P) conforming to MIL standard) V 0F D 06 0 Quick wiring permits easier Series 000 installation. Manifold Thread type Nil Rc F with D-sub connector G U side N NPT Connector mounting T NPTF direction 0 stations D D side mounting Port size D-sub connector U U side mounting 08 8 stations Passage Porting P, E, E, specifications 0 Max: D side P E, E (, ) 8 stations 06 Side M Mixed Plug assembly Common Common ottom (Option) For bottom ported: Option Refer to page --8. / only. Non Plug-in Type: Grommet Terminal, DIN Terminal Wiring for every valve Grommet terminal DIN terminal V Series 000 Manifold Non plug-in type 0 stations 0 Note) Manifold base is common for Series S000. Terminal block is not required. 0 0 stations 0 0 Passage Porting P E, E specifications (, ) Side Common Common ottom Option Port size 0 06 M P, E, E Thread type Nil F N T, Mixed For bottom ported: / only. Rc G NPT NPTF --8

86 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series Manifold/Option Parts ssembly Individual SUP spacer Supply port can be located at each valve individually after individual SUP spacer is mounted on manifold block. ody type Part no. VS000-P-0- Non plug-in type VS000-P-0- Throttle valve spacer Mount interface speed control on manifold block. Cylinder speed can be controlled by metered out flow. ody type Part no. VS Non plug-in type VS Manifold Option With exhaust cleaner /Non plug-in type High noise reduction effect: d or more Drainage and mist are collected (99.9% or more). Piping work is reduced. Individual EXH spacer Exhaust port can be located at each valve individually after individual EXH spacer is mounted on manifold block. (Common EXH type) ody type Part no. VS000-R-0- Non plug-in type VS000-R-0- SUP block disk When or more pressures (high and low) are supplied to one manifold, insert a disk between the stations which are supplied different pressures. ody type Part no. Non plug-in type XT68- EXH block disk Use exhaust blocks to eliminate back flow to other stations. Use supply disks to operate two pressures on the same manifold. ody type Part no. EXH block disk Non plug-in type XT-- SUP block disk Interface regulator When interface regulator is mounted on manifold block, regulation to that valve is possible. (Refer to Flow Characteristics on page --8 before operation.) ody type Non plug-in type P port regulation RF00-00-P- RF00-00-P- reduced pressure RF RF reduced pressure RF RF lanking plate It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. ody type Part no. Non plug-in type VS000-0 For details, refer to page With serial interface unit for serial transmission Reduces wiring labor and material to manifold. Possible to locate separately. Manifold solenoid valve: 8 stations max, positions ( solenoids). Easy maintenance For details, refer to Serial Transmission catalog separately. VP S S VS N --8

87 Series Manifold /Non plug-in type (With terminal block): V-0T- Station - ore size Manual override (Non-locking). 0 (7) R. U side L ottom ported: Formula for manifold weight M = 0.9n +.6 (kg) n: Station Non plug-in type: V-0- Station - ore size ottom ported: V-0- Station - Port size DIN terminal MX.0. L L (Pitch) P = 7. (Pitch) P = Common terminal n-rc / V-0T- Station - ore size n-rc / pplicable cable O.D. ø6.8 to ø0 G / -Rc /8 (PE port) External pilot port Rc /8 6-Rc / (P, E, E port) E PE X P G / (Lead wire electrical entry) Formula L = x n + 9 L = x n + 0 E PE Light/Surge voltage suppressor (For DZ) PE E n Light/Surge voltage suppressor ø. (Electrical entry) Manual override (Non-locking) n n: Station PE E X P (7) PE E L L n-rc /, / D side (, port) U side Grommet with terminal X P PE E R. External pilot port Rc /8 -Rc /8 (PE port) 6-Rc / (P, E, E port) 9 9 L L D side n-rc /, / (, port) -Rc /8 (PE port) 6-Rc / (P, E, E port) External pilot port Rc /8 70 [7.] [] [ ] =, port Rc / 70 [7.] 6 [] (Pitch) P = 6 [] 7. (Pitch) P = 7. [] Formula for manifold weight M = 0.8n +. (kg) n: [ ] =, port Rc / --86

88 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series Manifold : With multi-connector/with D-sub connector L /With multi-connector: V-0CD- Station - ore size, V-0CU- Station - ore size ottom ported: CD V-0 - Station - ore size CU ottom ported: FD V-0 - Station - ore size L L (Pitch) P = (Pitch) P = FU 96 n-rc / Manual override (Non-locking) Formula L = x n + 9 L = x n + 0 -Rc /8 (PE port) PE X P PE E 0 D side External pilot port Rc / Rc / Formula for manifold weight M = 0.96n (kg) n: 6 (P, E, E port) For wiring specifications, refer to page [ ] =, port Rc / 7. n-rc / 0 -Rc /8 (PE port) PE E E. 0 (7) Plug assembly: 09 VS (Option: Refer to page --8.) Manual override (Non-locking) Light/Surge voltage suppressor Light/Surge voltage suppressor Plug assembly: VS000-- (Option: Refer to page --8.) Formula for manifold weight M = 0.96n +.6 (kg) n: For wiring specifications, refer to page --8. n: Station n n X P (7) PE E R. R. L L 9 L L Rc / (P, E, E port) n-rc /, / (, port) n-rc /, / (, port) External pilot port Rc / [] (Pitch) P = 7. [] 70 [7.] /With D-sub connector: V-0FD- Station - ore size, V-0FU- Station - ore size U side U side D side 70 [7.] 6 [] Pitch P = 7. [] [ ] =, port Rc / VP S S VS N --87

89 Series Manifold with Exhaust Cleaner Protection of work environment Reduction of valve exhaust noise of d or more Drainage and mist are collected. (99.9% or more) Piping work is reduced. Manifold Specifications Wiring Manifold pplicable valve model Porting specifications RC pplicable exhaust cleaners : V-0 Non : V-0 With terminal block DIN terminal With multi-connector Grommet terminal With D-sub connector 00-F 0-D, 0-E Common SUP/Common EXH, port Side: Rc /, /, ottom: Rc / (Option) P port Side: Rc / EXH: Rc / to 0 () MC80- (Connecting port R /) () Note ) With multi connector, or with D-sub connector: 8 stations max. Note ) Exhaust cleaner: Not attached. U side Non Exhaust cleaner (Option) Exhaust cleaner (Option) D side How to Order Manifold ssembly V Series 000 Manifold Valve arrangement is counted from the D side. When ordering, specify the part nos. in order from the st. station in the D side. When entry of part numbers becomes complicated, indicate on the manifold specification sheet. Caution When using exhaust cleaner, mount it downwards. How to Order CD Instruct by specifying the valves and blanking plate to be mounted on the manifold along with the manifold base model no. <Example> with terminal block: 6 stations <Example> Non plug-in type: 6 stations V-0T-06-0-CD set (Manifold part no.) 00-FZ sets ( position single part no.) 00-FZ sets ( position double part no.) VS000-0 set (lanking plate assembly part no.) MC80- set (Exhaust cleaner part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. ase type/ Electrical entry 0T With Terminal block 0C with multi-connector 0F with D-sub connector 0 Non plug-in type Connector mounting direction With connector pplicable base Nil None 0T, 0 D D side mounting 0C, 0F U U side mounting 0 stations 0 0 stations ase 0T, 0: to 0 stations ase 0C/0F: to 8 stations Exhaust cleaner mounting direction Exhaust cleaner mounting direction CD D side D side mounting CU U side U side mounting Thread type Nil Rc F G N NPT T NPTF Port size P, E, E, 0 0 M Mixed For bottom ported: / only. Passage Porting specifications P E, E (, ) Side Common Common ottom Option V CU set (Manifold part no.) 0-E sets ( position single part no.) 0-E sets ( position double part no.) VS000-0 set (lanking plate assembly part no.) MC80- set (Exhaust cleaner part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Valve arrangement is counted from the D side. When ordering, specify the part nos. in order from the st. station in the D side. When entry of part numbers becomes complicated, indicate on the manifold specification sheet. --88

90 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series Manifold with Exhaust Cleaner /Non plug-in type : V-0T- Station - ore size - CD CU 9 L L COM terminal 9 L L ø ø 9 [ ] =, port Rc / Light/Surge voltage suppressor Manual override (Non-locking) n MC80- Exhaust cleaner (Option) -Rc /8 (PE port) -G / (Electrical entry) ø, (Electrical entry) Manual override (Non-locking) n MC80- Exhaust cleaner (Option) -Rc /8 (PE port). 0 (7) PE E PE E R. 0 (7) PE E X X P P PE E R D side mounting D side mounting External pilot port 0 U side R / D side External pilot port Rc /8 n-rc / (P port) 67 8 n-rc /, / (, port) Non plug-in type: V-0- Station - ore size - CD CU [ ] =, port Rc / U side R / D side -Rc / (P port) n-rc /, / (, port) Rc /8 L L L [7.] [] 6 [] (Pitch) P = 6 [] [7.] [] (Pitch) P = Manual override (Non-locking) D side n U side D side Manual override (Non-locking) n U side mounting U side U side mounting ø ø Common terminal n: Formula L = x n + 9 L = x n + 0 VP S S VS N --89

91 Series Manifold Option Parts ssembly, Non plug-in type Individual SUP spacer VS000-P-0- () VS000-P-0- (Non plug-in type) Interface regulator/p port regulation RF00-00-P- () RF00-00-P- (Non plug-in type) Individual SUP spacer Rc / Interface regulator Individual EXH spacer VS000-R-0- () VS000-R-0- (Non plug-in type) Individual EXH spacer SUP block disk: XT68- EXH block disk: XT-- lock disk mounting position ( ) : SUP block disk Throttle valve spacer VS () VS (Non plug-in type) Throttle valve spacer Rc / Interface regulator/ port regulation RF () RF (Non plug-in type) Interface regulator Interface regulator/ port regulation RF () RF (Non plug-in type) Interface regulator --90

92 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series Manifold ase Construction /Non plug-in type Replacement Parts No. q w e r t y u i o! Replacement Parts: Sub ssembly No.!0!! Description Connection fitting Connection fitting O-ring O-ring O-ring O-ring O-ring Terminal block assembly Junction cover assembly Rubber plug Description Manifold block assembly End plate (U side) assembly End plate (D side) assembly Material Steel plate Steel plate NR NR NR NR NR For 0T For 0SU NR Manifold block End plate (U side) ssembly part no VS VS000-- VS000-- VS000-- VS000-- Part no. XT68-6- XT68-6- S S68-00 S68-0 S68-0 S VS000-- Z78-- XT End plate (D side) When requiring replacement manifold stations, order replacement parts assembly no.!0: manifold block assembly part. For plug-in type: The manifold base with terminal stand (integrated with a junction cover) is required with the o junction cover assembly. Note) Manifold ase/construction: with terminal block. Component parts Manifold block!0, Metal joint q, w, Terminal block i, O-ring e, r, t, y, u, Receptacle assembly Manifold block!0, Metal joint q, w, O-ring e, r, t, y, u End plate (U)!, Metal joint q, w End plate (U)!, Metal joint q, w End plate (D)!, Metal joint q, w, O-ring e, r, t, y, u End plate (D)!, Metal joint q, w, O-ring e, r, t, y, u pplicable manifold base Non plug-in type Non plug-in type Non plug-in type VP S S VS N --9

93 9 --9

94 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Double Non plug-in type JIS position position Single Closed center ()() ()() (E)(P)(E) ()() (E)(P)(E) (E)(P)(E) Exhaust center () () (E)(P)(E) Pressure center () () (E)(P)(E) Caution When double solenoid is used, spool valve should be mounted horizontally. If there are vibrations, spool valve should be mounted perpendicular to the vibration direction. Series 6000 For details about certified products conforming to international standards, visit us at 9 Standard Specifications Valve specifications Electricity specifications Fluid Operating pressure range mbient and fluid temperature Lubrication Manual override Shock/Vibration resistance Enclosure Coil rated voltage llowable voltage fluctuation Inrush pparent power (C) () Holding Power consumption (DC) () Electrical entry Option Specifications position single/ position position double ir 0. to 0.9 MPa 0. to 0.9 MPa 0 to 0 C (No freezing. Refer to page --.) Non-lube () Non-locking push type 00/0 m/s () Dustproof 00, 00 VC (0/60 Hz), VDC to 0% of rated voltage.6 V/0 Hz,.0 V/60 Hz. V/0 Hz,. V/60 Hz Non plug-in type.8 W Conduit terminal Grommet terminal, DIN terminal Note ) t rated voltage Note ) Use turbine oil Class (ISO VG), if lubricated. Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Main valve manual override Coil rated voltage Option Model Type of actuation position position Single Plug-in Double 60 Closed 60 center Exhaust 60 center Pressure 60 center Type of actuation position position Single Double Closed center Exhaust center Pressure center 60 Plug-in Model Model Non plug-in Non plug-in Port size Port size Direct manual override 0 to 0, 0, 0 VC 0/60 Hz, 00 VDC With light/surge voltage suppressor Flow characteristics () / (P /) / / (/ E/E) C [dm / (s bar)] [0] b [0.] Cv [.7] C [dm / (s bar)] 9 [0] 0 b [0.] Effective area (mm ) Cv [9.] () Max. operating cycle (Hz) () Response time (ms) 00 or less 00 or less 0 or less 0 or less or less () Weight (kg).7 (.6).78 (.6).7 (.).7 (.).7 (.) Note ) [ ]: Denotes the normal position. Note ) Min. operating frequency is once in 0 days. (ased on JIS 87) Note ) ased on dynamic performance test, JIS (Coil temperature: 0 C, at rated voltage, without surge voltage suppressor) Note ) For 600-FZ-06, ( ): 60-DZ P, : 78, E, E: Normal position: 9 P, : 8 Normal position: 8, E, E: VP S S VS N

95 Series How to Order Electrical entry F:, conduit type Option Nil Z None With light/surge voltage suppressor Not applicable to grommet terminal. Port size Nil Without sub-plate 06 0 Plug-in F 0 Non plug-in position single ()() (E)(P)(E) position double ()() (E)(P)(E) position closed center ()() (E)(P)(E) position exhaust center ()() (E)(P)(E) position pressure center () () (E)(P)(E) 6 ody option 0 Standard Direct manual override Option 6 7 Coil rated voltage 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 to 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC VDC 0 VC, 0/60 Hz 9 Other Option How to Order Pilot Valve ssembly SF F Coil rated voltage Rated voltage 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 to 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC 6 VDC 7 0 VC, 0/60 Hz 9 Other Option D 0 Electrical entry E: Grommet terminal Thread type Nil Rc F G N NPT T NPTF D: DIN terminal --9

96 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series Cylinder Speed Chart Series Conditions 60-0 verage speed (mm/s) Tube x Length Speed controller Silencer How to Order Sub-plate ssembly Plug-in 6000 P 0 Non plug-in S6000 S 0 Use as a guide for selection. Please confirm the actual conditions with SMC Sizing Program. ore size Series CS Pressure 0. MPa Load factor 0% Stroke 00 mm ø ø0 ø60 ø80 ø00 ø0 ø00 Note) Not applicable for external pilot. Not applicable for bottom ported. Mounting bolt and gasket are not included. Series CS SGP x m N600-0 S600-0 Piping port (P,,, E, E port) 06 0 Perpendicular, upward actuation Horizontal actuation It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. Load factor: ((Load weight x 9.8)/Theoretical force) x 00% Thread type Nil Rc F G N NPT T NPTF VP S S VS N --9

97 Series Construction position single position double 60 () () 60 ()() (E)(P)(E) (E)(P)(E)! i u q e t! i u q!0 e No. q w e r Closed center: 60 () () Exhaust center: 60 () () Pressure center: 60 () () Component Parts Description ody Sub-plate Spool valve dapter plate Replacement Parts No. o!0! r y --96 PE (E) () (P) () (E) leed PE (E) () (P) () (E) PE (E)(P)(E) (E)(P)(E) (E)(P)(E) Description Gasket Hexagon socket head screw Pilot valve assembly position closed center/exhaust center/pressure center Material luminum die-casted luminum die-casted luminum, NR luminum die-casted Material NR Steel r Note Platinum silver Platinum silver lack o 6 S6000- M8 x 80 r w! i q!0 e PE (E) () (P) () (E) PE No. t y u i Description End plate Junction cover Light cover Pilot valve cover o This figure shows a closed center type. Material luminum die-casted Resin Resin Resin Part no. 6 S6000- M8 x 80 Refer to How to Order Pilot Valve ssembly on page --9. o Note lack lack lack 6/6/6 S6000- M8 x 80

98 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series Plug-in position single/double, position closed center/exhaust center/pressure center position single: 60 -F(Z) 0.. -Rc /, (Piping port) 7 -ø. 7 (Electrical entry) Manual override (Non-locking) Light/Surge voltage suppressor (For FZ) PEE E PE position double: 60 -F(Z) position closed center: 60 -F(Z) 0 position exhaust center: 60 -F(Z) 0 position pressure center: 60 -F(Z) ø. 6 9 (Electrical entry) 7 G / G / Manual override (Non-locking) Rc /8 (PE port) Light/Surge voltage suppressor (For FZ) 0 PE E P P E PE ø9 (Mounting hole) 7. 6 Rc /8 (leed port) (Double, position: PE port) ø9 (Mounting hole) 0 Other dimensions are the same as the single type. VP S S VS N --97

99 Series Non Plug-in position single/double, position closed center/exhaust center/pressure center position single: 6 -E, 6 -D(Z) Rc /, (Piping port) pplicable cable O.D. ø6.8 to ø pplicable cable O.D. ø6.8 to ø0 Manual override (Non-locking) Light/Surge voltage suppressor (For DZ) 0 6. Rc /8 (PE port) Manual override (Non-locking) Light/Surge voltage suppressor (For DZ) PE E MX.0 7 P PE E P E PE G / 9 E PE Electrical entry (-ø.) ø9 (Mounting hole) 7. 6 Rc /8 (leed port) (Double, position: PE port) position double: 6 -E, 6 -D(Z) position closed center: 6 -E, 6 -D(Z) 0 0 position exhaust center: 6 -E, 6 -D(Z) 0 0 position pressure center: 6 -E, 6 -D(Z) Electrical entry (-ø.) ø9 (Mounting hole) 0 0 Other dimensions are the same as the single type. --98

100 Large Size Port Solenoid Valve Rubber Seal Series VP0/70 Piping 0 Side ported ottom ported Without sub-plate Option VP Series VP port solenoid valve Type of actuation position single position double position closed center position exhaust center 7 ody style Port size 00 Port size Without sub-plate 0 8 (0) 0 () 06 (0) 0 () () (0) How to Order Standard Standard 0 pplicable valve model VP VP7 VP0 VP70 0 VT T Rated voltage Electrical entry G T D TL DL Option Nil F N T Rated voltage 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC 6 VDC 7 0 VC, 0/60 Hz 9 Other Option How to Order Pilot Valve ssembly VC, 0/60 Hz 00 VC, 0/60 Hz 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC 6 VDC 7 0 VC, 0/60 Hz 9 Other Option Thread type Rc G NPT NPTF Grommet Conduit terminal DIN terminal Conduit terminal with indicator light DIN terminal with indicator light G Note) There is no position type for Series VP70. Electrical entry Note) G Grommet Note) Even if the electrical entry of the solenoid valve is T, D, TL, or DL, the electrical entry for pilot valve assembly is chosen for G. VP S S VS N -6-

101 Series VP0/70 JIS VP0/70 VP0 VP0/70 VP0 Flow Characteristics/Weight position position position position Made to Order Specifications (For details, refer to page -6-.) Type of actuation Single Double Closed center Exhaust center Type of actuation Single Double Closed center Exhaust center Model VP0 VP0 VP0 VP0 Model VP0 VP70 VP0 VP70 VP0 VP0 Port size Port size Specifications Fluid Operating pressure range (MPa) mbient and fluid temperature ( C) Max. operating frequency (Hz) Lubrication () Manual override Mounting orientation Impact/Vibration resistance (m/s ) () ccessory (Standard equipment) Solenoid Specifications Response Time Note) ir 0. to to 60 (No freezing. Refer to page --.) Required (Turbine oil Class ISO VG) Yes (Non-locking) Unrestricted 0/0 Silencer for pilot EXH ( N0-0 ) Note ) This solenoid valve requires lubrication. Use turbine oil Class (ISO VG). Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Electrical entry Standard Option C (0/60 Hz) Coil rated voltage (V) DC llowable voltage fluctuation Note) Inrush pparent power (V) C Holding Power consumption (W) Note) DC Option Note) t rated voltage Response time (ms) (at the pressure of 0. MPa) Grommet (G) Conduit terminal (T) DIN terminal (D) Conduit terminal with indicator light (TL) DIN terminal with indicator light (DL) 00, 00, 0, 0, 0,, 8, 00 to +0% of rated voltage 7 (0 Hz), 8 (60 Hz) 8 (0 Hz), 7 (60 Hz) Model VP0 VP70 VP0 VP70 VP0 VP0 ON 0 or less 0 or less 0 or less 0 or less 0 or less 0 or less C OFF 0 or less 6 or less 0 or less 0 or less 0 or less 0 or less ON 0 or less or less 0 or less or less 0 or less 0 or less DC OFF 0 or less or less 0 or less or less 0 or less 0 or less Note) ased on dynamic performance test, JIS (Coil temperature: 0 C, at rated voltage, without surge voltage suppressor.) Flow characteristics / (P /) / / (/ E/E) C [dm /(s bar)] b Cv Effective area (mm ) Weight (kg) C [dm /(s bar)] b Cv () 9 (6) (8) Weight (kg) (0.8). (.0).6 0. (0.7).8 (.) 0. (0.0). (.8). ( ): Denotes the normal position. -6-

102 Large Size Port Solenoid Valve Rubber Seal Series VP0/70 Precautions e sure to read before handling. For Safety Instructions and Solenoid Valve Precautions, refer to page --. Caution. Piping Make P port piping so that supply air pressure does not become lower than operating pressure while operating. If throttling air flow of P port, or opening / ports in the atmosphere (or opening in almost the same conditions), pressure drop at operating can cause malfunction of the valve.. ir quality Install an air filter and a lubricator on the upstream side.. Lubrication This solenoid valve requires lubrication. Use turbine oil Class (ISO VG). esides that, for brands of each manufacturer, refer to page --.. Operating environment Install silencer in E/E/Pilot EXH port to prevent dust from entering in the dusty ambient.. Operation at low temperature If operating at 0 C or less, external pilot style solenoid valve is recommended. (Made to order; suffix -X0 to the part number.) 6. Regarding VP ( position closed center type) e aware that when the cylinder is in an intermediate stop state, if the supply pressure to the P port is discharged or decreased, this valve is constructed so that the pressure in the cylinder will be discharged to the P port, causing the cylinder to move. 7. How to calculate the flow rate For obtaining the flow rate, refer to page --0. How to Use DIN Terminal. Disassembly ) fter loosening the thread (), then if the cover () is pulled in the direction of the thread, the connector will be removed from the body of equipment (solenoid, etc.). ) Pull the screw (), and then remove gasket (a) or (b). ) On the bottom part of the terminal block (), there s a cut-off part (indication of an arrow). If a small flat head screwdriver is inserted between the opening in the (a) bottom, terminal block () will be removed from the cover (). (Refer to figure at right.) ) Remove the cable gland () and plain washer (6) and rubber seal (7).. Wiring ) Pass them through the cable (8) in the order of cable ground (), washer (6), rubber seal (7), and then insert into the housing (). ) Dimensions of the cable (8) are the figure as below. Skin the cable and crimp the crimped terminal (9) to the edges. ) Remove the screw with washer (e) from the bracket (e). (Loosen in the case of Y-shape type terminal.) s shown in the below figure, mount a crimped terminal (9), and then again tighten the screw (e). Note) Tighten within the tightening torque of 0. N m ± %. Note: a It is possible to wire even in the state of bare wire. In that case, loosen the screw with washer (e) and place a lead wire into the bracket, (d) and then tighten it once again. bmaximum size of crimped terminal (9) is up to. mm. when O terminal. For Y terminal, it is up to. mm. c Cable (8) external: ø6 to ø Note) For the one with the external dimension ranged between 9 to mmø, remove the inside parts of the rubber seal (7) before using. DlN Terminal (Connection). ssembly ) Terminal block () connected with housing () should be reinstated. ) Putting rubber seal (7), plain washer (6), in this order into the cable introducing slit on the housing (), then further tighten the cable gland () securely. ) y inserting gasket (a) or (b) between the bottom part of the terminal block () and a plug on an equipment, screw in () on top of the housing () and tighten it. Note) Tighten within the tightening torque of 0. N m ±%. Note: The orientation of a connector can be changed arbitrarily, depending on the combination of a housing () and a terminal block (). Solenoid is wired with male thread terminals of DIN connector as follows. Connect with corresponding terminals of the connector. Terminal Polarity side side COM Can be used as either +COM or COM. () () (d) (d) (c) () (a) (e) (b) (9) (a) (6) (7) (e) (9) (e) Self-up screw Magnifying figure () (8) VP S S VS N -6-

103 Series VP0/70 Construction position single position double Component Parts No. q w e r t y u i o Description ody Plate Cap Spacer Spool Sleeve Piston Center sleeve Side poppet Replacement Parts No.!0!! -6- Closed center Exhaust center Description Sub-plate Gasket Hexagon socket head screw Pilot valve assembly Material luminum alloy luminum alloy luminum alloy luminum alloy Stainless steel/luminum alloy position: luminum alloy position: rass position: Resin position: Stainless steel Resin rass, NR Part no. VS00-S-0 VS00-S-0 DXT-P-06 DXT-P-0 DXT--P- DXT--P- XT0-9 DXT-6 M6 x with washer M8 x VT-00G Silencer (N0-0) position closed center/exhaust center Note Platinum silver Platinum silver Platinum silver Platinum silver Silencer (N0-0) Note 8 VP0 luminum alloy VP70 in part numbers are the same symbol for the thread type in How to Order. VP0 VP70 VP0 Thread for mounting valve. spring washer VP70 will be required separately for VP70. Refer to How to Order Pilot Valve ssembly on page -6-. Silencer (N0-0)

104 Large Size Port Solenoid Valve Rubber Seal Series VP0/70 Dimensions: VP0 Grommet: VP0-G- ottom ported -ø9 mounting hole (ø) Manual override -/8, / (/, ) Conduit terminal: VP0-T- G / G / -/8, / (/, ) ( ): Rc /, ( ): Rc /, DIN terminal: VP0-D- G / pplicable cable O.D. ø6 to ø ( ): Rc /, VP S S VS N -6-

105 Series VP0/70 6 Dimensions: VP0/0/0 Grommet: VP0-G-, VP0-G- VP0-G- ottom ported Manual override -ø9 mounting hole (ø) -/8, / (/, ) position: 87 position: 0 position: 9 Conduit terminal: VP0-T- VP0-T- VP0-T- G / G / -/8, / (/, ) ( ): Rc /, DIN terminal: VP0-D- VP0-D- VP0-D- ( ): Rc /, G / pplicable cable O.D. ø6 to ø ( ): Rc /, -6-6

106 Large Size Port Solenoid Valve Rubber Seal Series VP0/70 7 Dimensions: VP70 Grommet: VP70- G- ottom ported -ø (Mounting hole) G / - /, / Manual override Conduit terminal: VP70- T- DIN terminal: VP70- D- G / G / (- /, /) pplicable cable O.D. ø6 to ø VP S S VS N -6-7

107 Series VP0/70 8 Dimensions: VP70 Grommet: VP70- G- ottom ported (Mounting hole) Manual override (- /, /) G / - /, / Conduit terminal:vp70- T- DIN terminal: 70- D- G / G / pplicable cable O.D. ø6 to ø -6-8

108 9 Series VP0 Manifold Specifications How to Order VVP Common EXH Precautions Individual EXH No manifold is available for Series VP70. Porting specifications 0 9 Specifications Specify the valves and blanking plate to be mounted on the manifold along with the manifold base model no. <Example> ase ( stations), Common EXH, 00 VC, DIN terminal, / port: Rc / VVP pc. VP-00D pcs. VP-00D pc. XT08N- pc. Manifold type mount Exhaust type Common EXH, Individual EXH () Supply type Common SUP Valve stations Max. 0 stations (VVP60: Max. 8 stations) () Note ) If throttling exhaust air, use individual exhaust style so that backing pressure does not cause trouble. Note ) In the case of stations or more, supply air pressure from both sides and exhaust from both sides. Simultaneous Operation of Manifold Valves Model Series VP port solenoid valve Manifold P Side Side Simultaneous operation of manifold valves can cause pressure drop. Series VVP0 VVP60 ase size 6, E Side ottom Note) Other Note) / port piping: Rc /8 or Rc / Option Side Side Valve stations 0 0 stations 0 stations / Port size Port size M Note) Mixed Exhaust Port size specifications P, E Common Individual, Common Individual, VVP0 VVP60 Note) In the case of Mix, put M in the part number and indicate each port size in other places. ase specifications Thread type Nil F N T Rc G NPT NPTF Common EXH Individual EXH How to Order Manifold ssembly The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. pplicable valve model VP-00 VP-00 VP-00 VP-00 VP S S VS N Option lanking plate assembly XT08N- With gaskets and bolts -6-9

109 Series VP0/70 0 Dimensions: VVP0/60 Common EXH: VVP0- Station - Port size - VVP60- Station - Port size - Grommet Conduit terminal DIN terminal Piping port G / G / Mounting hole ( ): VVP60 Individual EXH: VVP0- Station - Port size - VVP60- Station - Port size - Grommet Conduit terminal DIN terminal Mounting hole ( ): VVP60 Piping port n-/, / Piping port (/, ) Piping port () L Dimension Model VVP0 VVP60 Piping port L L Formula L = 87 x n + 8 L = 87 x n + L L = 08 x n + 90 L dimension L G / G / pplicable cable O.D. ø6 to ø pplicable cable O.D. ø6 to ø n: Station L = 08 x n

110 Made to Order Specifications: Series VP0/70 External Pilot/With Surge Voltage Suppressor External Pilot/-X0 Model no. VP ( ) X0 Entry is the same as standard products. Dimensions Same as those of standard models. For the external pilot port position, refer to the below. E VP0 8 ( position: 98.) P E 7(9.) /8 (External pilot port) Dimensions: Port size /8, / ( ): Port size /, With Surge Voltage Suppressor/-X Model no. VP ( ) X Dimensions Same as those of standard models. Entry is the same as standard products. E VP70 P 9 Electrical entry T Conduit terminal D DIN terminal TL Conduit terminal with indicator light DL DIN terminal with indicator light E 9. /8 (External pilot port) VP S S VS N -6-

111 For details about certified products conforming to international standards, visit us at Product Profile: ISO Standard Solenoid Valve: Size, Rubber Seal Series VP7-6/7-8 Solenoid valve conforming to ISO standard Size ()/VP7-6 Size ()/VP7-8 (Rubber seal) position position Single solenoid (FG-S) Double solenoid (FG-D) Reverse pressure (YZ-S) Reverse pressure (YZ-D) Closed center (FHG-D) Exhaust center (FJG-D) Double pilot check (FPG-D) Pressure center (FLG-D) VP7-6-FPG-D- VP7-6-FHG-D- VP7-6-FG-S- VP7-6-FG-D- VP7-6: Flow Characteristics Valve model VP7-6 position position position position Type of actuation ( ): Denotes the normal position. denotes the bottom ported type. VP7-8: Flow Characteristics Valve model VP position position position position Option Standard Specifications Fluid Single position position ir 0. to to 0.9 Operating pressure range Double position 0. to 0.9 mbient and fluid temperature Max. 0 C Manual override Non-locking type Electrical entry DIN terminal Lubrication Use turbine oil Class (ISO VG). Usable with non-lube. Shock/Vibration resistance Note) 00/0 m/s Port size Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center Rc / Rc / (.6) (.) Type of actuation ( ): Denotes the normal position. denotes the bottom ported type. Port size Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center Rc /8 Rc /8 (6.8) (6.) Note) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Flow characteristics / (P /) / / (/ R/R) C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv (0.) (0.7) (0.) (0.).....(0.89) (0.8).....(.8) (.6) (.).....(.). () (7.6) (0.) (0.) (0.) (0.) (.) (.0) 0.8 Flow characteristics / (P /) / / (/ R/R) C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv....(.).9....().0

112 Explosion Proof Solenoid Valve Series 0-E/0-VPE Explosion proof solenoid valve port/0-e000, 000 port/0-vpe00, 700 Quality of explosion proof spec. Conforming to International Standard (IEC standard) as well Type of explosion proof construction: Withstand pressure explosion proof construction dg (Certificate model no. 6) ExdT (Certificate model no. C60) This product is conforming to the conventional explosion-proof construction standard for the electric machine and apparatus (bulletin no. 6 pronounced by Japanese Labor Ministry in 969) and the new standard (technical standard newly established based on International Electrotechnical Commission (IEC standard 79)). Waterproof Conforming to JIS F 800 Class Sprinkle Test Exhausting equipment for pilot valve not required. Common exhaust type for main and pilot valve (0-E000) In order to protect the environment, exhaust from a pilot valve is discharged through common exhaust. Possible to be into manifold (0-E000, 0-E000) Can deal with the manifold type up to 0 stations at the maximum. s a selector valve, divider valve, or able to use for vacuum applications. (0-VPE00, 0-VPE700) If it is changed to external pilot method, universal porting will be available the same like direct type. nd it can be used in the vacuum applications. Series 0-E Specifications: 0-E000/000 Series Fluid Operating position single/ position pressure range position double mbient and fluid temperature position double Response time position Max. operating position double frequency position Lubrication Manual override Mounting orientation Pilot valve EXH Specifications: 0-VPE00/700 Fluid Type of actuation Pilot type Operating pressure range 0-E000 ms or less Note) 60 ms or less Note) Hz Hz Individual exhaust Common exhaust type for main and pilot valve ir 0. to 0.9 MPa 0. to 0.9 MPa Max. 0 C 0-E000 ms or less Note) 70 ms or less Note) Hz Hz Not required Non-locking push type, Push-turn locking type D Unrestricted Individual exhaust Pilot common exhaust Note) ased on dynamic performance test, JIS (Coil temperature: 0 C, at rated voltage, without surge voltage suppressor.) ir N.C. or N.O. (Convertible) Internal pilot External pilot 0. to 0.8 MPa Supply pressure External pilot pressure 0. kpa to 0.8 MPa 0. to 0.8 MPa mbient and fluid temperature Max. 0 C Response time ms or less (at 0. MPa) Note) Max. operating frequency Hz Lubrication Not required Non-locking push type Manual override Push-turn locking type D Mounting orientation Unrestricted Note) ased on dynamic performance test, JIS (Coil temperature: 0 C, at rated voltage, without surge voltage suppressor.) For details, please contact SMC. VP S S VS N Series 0-VPE -6-

113 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Plug-in Type ase Mounted Type (With sub-plate) Non Plug-in Type ase Mounted Type (With sub-plate) Plug-in Type Non Plug-in Type Series Sonic conductance Type of Voltage Electrical entry With light/surge Manual C [dm /(s bar)] actuation voltage suppressor override / / (Option) Note) S000 S000 S000 S000 Rc 8 Single position Double (Closed center).. Rc Single position Double (Closed center).. Rc 8 Single position Double (Closed center).. Rc Single position Double (Closed center).. position exhaust center position pressure center position double check Protective circuit is connected in the course of the lead wire. Note) The plug-in type and K plug connector type are taken as standard with light/surge voltage suppressor. Manifold Variations Valve series S000 S000 S000 S000 Manifold type Stacking type with D-sub connector of MIL standard (Package one-touch connection) ttachment plug with lead wire Stacking type (Individual connection to each valve) position single position double position closed center (Standard) 00 VC, 0/60 Hz 00 VC, 0/60 Hz VDC (Option) VC, 0/60 Hz 8 VC, 0/60 Hz 0 VC, 0/60 Hz 0 VC, 0/60 Hz 6 VDC VDC 8 VDC Manifold Option With With serial With coaxial control unit transmission unit fitting Plug-in (F) Grommet (G) L plug connector (L) M plug connector (M) K plug connector (K) DIN terminal (D) Individual Individual SUP spacer EXH spacer SUP block disk With light/surge voltage suppressor (FZ) With surge voltage suppressor (FS) With light/surge voltage suppressor L plug connector (LZ) M plug connector (MZ) K plug connector (KZ) DIN terminal (DZ) With surge voltage suppressor Grommet (GS) L plug connector (LS) M plug connector (MS) K plug connector (KS) DIN terminal (DS) Option Parts EXH block disk Throttle valve spacer Double check spacer Non-locking push type (Flush) Locking type (Tool required) Interface regulator lanking plate Page -7-7 Page -7- Page -7-7 Page -7- Page VP S S VS N -7-

114 Series S000/000 Precautions e sure to read before handling. For Safety Instructions and Solenoid Valve Precautions, refer to page --. ttaching and detaching connectors. ttaching To attach a connector, hold the lever and connector unit between your fingers and insert straight onto the pins of the solenoid valve so that the lever s pawl is pushed into the groove and locks.. Detaching To detach a connector, remove the pawl from the groove by pushing the lever downward with your thumb, and pull the connector straight out. L/M Plug Connector Type K Plug Connector Type L/M plug connector assembly DXT70 Nil Caution L Mold coil Concave Pin Cover M 80 Lead wire color Lead wire with socket Socket only ( pcs.) lue () Red () Gray () Cover Mold coil Pin Connector Pin Note Cover Without lead wire For 00 VC For 00 VC nother VC Red: +, lack: For DC Lead wire length Lead wire length (mm) Nil Note) When ordering a valve in which the length of the wire is more than 600 mm, be sure to indicate the model number of valve without connector and connector assembly. Ex.) For lead wire length (000 mm) S0-MO-0 pcs. DXT pcs.. How to Use Non Plug-in Type and Plug Connector Lever DC polarity indication Hook Red Socket part no.: DXT70-7- lack Lead wire 0. to 0. mm (Max. covering O.D.: ø.7 mm) DC coils are + Red and lack. Socket part no.: DXT70-7- Lead wire 0. to 0. mm (Max. covering O.D.: ø.7 mm) White( side solenoid) Red (COM) lack ( side solenoid) K plug connector assembly XT70 0 Number of solenoid Lead wire with socket Note Nil Socket only ( pcs.) Without lead wire For single solenoid lack/red In common Double solenoid between lack: side C and DC Red: COM White: side Lead wire length Lead wire length (mm) Nil Crimping of lead wires and sockets Peel. to.7 mm of the tip of lead wire, enter the core wires neatly into a socket and crimp it with a special crimp tool. e careful so that the cover of lead wire does not enter into the crimping part. (Crimping tool part no.: DXT70-7-) Core wire Crimping crimping area area Terminal Hook ttaching and detaching lead wires with sockets. ttaching Insert the sockets into the square holes of the connector (with + and indication) and, continue to push the sockets all the way in until the lock by hooking into the seats in the connector. (When they are pushed in, their hooks open and they are locked automatically.) Then confirm that they are locked by pulling lightly on the lead wires.. Detaching To detach a socket from a connector, pull out the lead wire while pressing the socket s hook with a stick having a thin tip (approx. mm). If the socket will be used again, first spread the hook outward. Socket Hook Core wire Insulation Connector Lead wire Lead wire -7-

115 Series S000/000 Caution Connector assembly with protective Cover Connector assembly with protective cover enhances dust protection Effective to prevent short circuit accidents due to penetration of foreign matter into the connector section. The material of cover is chloroprene rubber for electricity which is excellent in weathering and electrical insulating properties. ut don t splash with cutting oil. Simple and unencumbered appearance by adopting round-shaped cord. How to Order DXT70 Lead wire length Lead wire length (L mm) 00 Nil Dimensions: Connector ssembly with Cover Red lack lack Polarity indication How to wire DIN terminal Connection. Loosen the set screw and pull out the connector from the terminal block of the solenoid.. Pull out screw and insert a screwdriver to the slit area near the bottom of terminal block to separate block and housing.. Loosen the terminal screws (slotted screws) on the terminal block, insert the core of the lead wire into the terminal in accordance with the prescribed connection method, and attach securely with the terminal screws.. Tighten the ground nut to secure the wire. Change of electrical entry (Orientation) fter separating terminal block and housing, the cord entry direction can be changed by attaching the housing in the desired direction ( directions in 90 increments). In the case of w/ indicator light, avoid damaging the indicator light with lead wire. Precautions Plug a connector in or out vertically, never at an angle. pplicable cable O.D.: ø. to ø7 (Reference) 0. mm core and core wires equivalent to JIS C 06. Ground nut Tightening torque.6 to. N m Washer Grommet (Rubber) (Voltage symbol) Refer to the table below. Terminal screw ( locations) Tightening torque 0. to 0. N m Holding screw Tightening torque 0. to 0. N m Housing (Position for light mounting) Terminal block Shaved part. Light/Surge Voltage Suppressor Plug-in ase Type/K Plug Connector Type FZ With indicator light (C) Neon bulb Due to the use of non-polar light, the S series has no polarity. Grommet Type C L/M Plug Connector Type Type LZ Type MZ Coil Coil Indicator light Type KZ With indicator light (DC) Red lack Type GS In applications where the supply voltage is DC, correctly connect the lead wires to + (positive) and (negative) indications on the connector. For those on which the lead wires have been pre-wired, the plus side is red and minus side is black. Diode C Red Neon bulb lack C C Diode Coil Coil Coil Coil With indicator light (C) Coil With indicator light (DC) Coil VP S S VS N -7-

116 Series S000/000 Caution DIN Terminal Plug-in base type sub-plate C Marking Indicator light (uilt-in connector) DC Marking C Surge voltage suppressor (uilt-in terminal block) Coil DC Diode Coil White ( side solenoid) K plug connector lack ( side solenoid) Red (COM) In the case of DC wiring, connect terminal no. of the connector to the positive (+) side, and terminal no. to the negative ( ) side. (Refer to the marks on the terminal board.) DIN Terminal Part No. Without indicator light With Indicator Light Circuit with Indicator Light Single unit. Wiring Specifications Since the sub-plate of plug-in base type and the lead wire of K plug connector type are connected with valves as shown in the following table, they should be connected with each power side. Since DC has no polarity, the polarity of COM is possible for either + or. Lead Wire Color Valve Lead wire color With indicator light (C) Neon bulb Varistor Coil Single solenoid type side solenoid lack: Red: COM DXT Rated voltage Voltage symbol Part no. 00 VC 00 VC 0 VC 00V 00V 0V DXT DXT DXT VC 0V DXT VC 6 VDC VDC VDC 8 VDC 0V 6VD VD VD 8VD DXT DXT DXT DXT DXT C Circuit diagram NL: Neon bulb R: Resister With indicator light (DC) Diode DC Circuit diagram D: Protective diode LED: Emitting diode R: Resister Double, position type side solenoid lack: Red: COM Coil side solenoid White: Red: COM White ( side solenoid) Red (COM) Single solenoid style has leads of red and blue.. Wiring Specifications Manifold base Type G with D-sub connector How to open a junction cover Open the cover by inserting a flat headed screwdriver to the upper part of junction cover as shown in the figure. For closing, close by pushing the cover until the application of the hook is heard. Note) Forced pulling of the cover may remove it. In this case, there is no problem closing the cover to put () the projection into () the groove. Connection () () Manifold block is equipped () attachment plug and lead wire is connected (plug-in) with the valve side as shown in the following table. The lead wires should be connected with each power side. Since DC has no polarity, the polarity of COM is possible for either + or. Lead Wire Color Valve Lead wire color K plug connector lack ( side solenoid) Single solenoid type side solenoid lack: Red: COM Double, position type side solenoid lack: Red: COM () Lead wire length: 0.6 m side solenoid White: Red: COM -7-

117 Series S000/000 Type F with D-sub connector Use of D-sub connector for electric connection system leads to rationalization and labor saving in the connection work. ecause MIL standard D-sub connector ( pin) is used as the connector, a wide interchangeability is obtainable. Wiring specifications The inside of the manifold is wired with connector terminals on the solenoid side and side according to COM specification as shown in the following diagram. Since DC has no polarity, the polarity of COM is possible for either + or. Internal wiring of manifold Connector Connector terminal no. terminal no. station U side (9 stations) stations (0 stations) stations ( stations) stations station D side (n) () () () () U side U side (n) Caution 8 stations (Max. 6 stations) D side ( ) is for the case of a D-sub connector for both sides (F type). Connector terminal no. station Pressure switch stations ir release valve D side VS000-- D-sub Connector Cable ssembly Terminal No. Terminal Lead wire No. color lack rown Red Orange Yellow 6 Pink 7 lue 8 Purple 9 Gray 0 White White Yellow Orange Yellow Pink 6 lue 7 Purple 8 Gray 9 Orange 0 Red rown Pink Gray lack White Dot marking None None None None None None None White lack lack Red Red Red lack lack White None None lack White White Red Red White None Note ) Regardless of the D-sub connector mounting position, stations are to be counted from D side as the st one. Note ) The maximum number of stations is 8 stations in a D-sub connector one D side fitting (Type F U ) and is 6 stations in both sides fitting (Type F). y COM specifications, maximum, stations are possible. pplicable Plug ssembly (D-sub connector cable assembly) (Option) Cable length. m m m 8 m ( stations) Unused stations ( stations) 6 stations ( stations) 7 stations ( stations) Inside wiring of manifold with control unit stations stations Unused stations 6 stations ir release valve Pressure switch 7 stations 8 stations Connector terminal no. ssembly part no. VS000-- VS000-- VS000-- VS000-- pplicable plug assembly (D-sub onnector cable assembly) Component parts Plug MIL standard D-sub connector D-sub connector Number of terminals: Cable: cores x 0. mm. Replacement Replacement of solenoid valves Loosen the fitting machine screws of solenoid valve and then pull out the solenoid valve body in a straight line. clamping torque of the fitting machine screws should be 0 to 0 N m. How to Calculate the Flow Rate For obtaining the flow rate, refer to page D-Sub Connector Manifold lock ssembly Precautions for ordering The shape of the D-sub pin of the lead cable assembly that is provided with the D-sub connector timer manifold block assembly has been newly changed. When ordering a manifold block assembly, verify whether it is the old or the new style, and use the part numbers listed below. ll lots have been changed to the new style starting with the February, 997 shipment (Lot no. P). New/Conventional D-sub connector Color New D-sub connector Silver Conventional D-sub connector Chromated Silver Dimple Chromated color <New style> <Conventional style> ppearance With dimple Without dimple Hook D-sub pin end Manufacturer JST Manufacturing Corp. Ltd. Hirose Electric Co., Ltd. Hook D-sub pin end New/Conventional manifold block assembly part no. For S000 New block assembly part no. (N) VS000---ore size- (-X) Conventional block assembly part no. (N) VS000---ore size (-X) For S000 New block assembly part no. (N) VS000---ore size- (-X) Conventional block assembly part no. (N) VS000---ore size (-X) Note) -X shows the part no. for all common style. VP S S VS N -7-

118 Series S000/000 6 Caution 7. Part number for Screws and Gasket ssembly Precautions on ordering The interface gasket configuration between valve manifolds has been changed in line with the configuration changes of the valve interface. When ordering screw and gasket assembly part numbers, confirm the new and old valve interface and then order with the following part number. ll lots have been changed to the new style starting with the pril, 00 shipment (Lot no. FR). How to confirm the new and old valves interface New Old Valve interface With gasket groove Without flat surface groove Screw, gasket assembly part no. For S000 New: G-S000- (Ditch groove): Set of gasket pc. and mounting screw pcs. Old: G-S000 (Plate gasket): Set of gasket pc. and mounting screw pcs. For S000 New: G-S000- (Groove gasket): Set of gasket pc. and mounting screw pcs. Old: G-S000 (Plate gasket): Set of gasket pc. and mounting screw pcs. -7-6

119 For details about certified products conforming to international standards, visit us at 7 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 Model Type of actuation position position Single Model S0 Port size Rc 8 Flow characteristics / (P /) / / (/ R/R) C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv. Double S Closed center S Exhaust center S Pressure center S Double check S Note ) Min. operating cycle is based on JIS 87 (One time per 0 days). Note ) Response time is based on JIS (0. MPa, without light/surge voltage suppressor) Note ) For S0-FZ-0 Note ) Note and Note are with controlled clean air. Reduction of wiring cost MIL standard D-sub connector with one-touch connection () Compact and large valve capacity: Width mm Flexible to increase and decrease manifold stations (Stacking type manifold base) High frequency/long service life (more than 0 mil. times) Possible to use in nonlubrication and dry air (Metal seal structure) Different variations for connection Grommet type L, M plug connector type: Individual take out of and sides K plug connector type: Common take out of and sides DIN terminal type: individual take out of and sides little power consumption:.8 WDC For serial transmission Standard Specifications Valve specifications Electricity specifications. Fluid Maximum operating pressure Minimum operating pressure Proof pressure mbient and fluid temperature Lubrication Pilot valve manual override Shock/Vibration resistance (m/s ) Enclosure Coil rated voltage llowable voltage fluctuation Coil insulation type Inrush pparent power (C) Holding Power consumption (DC) Electrical entry Max. operating cycle (CPM) () () () Response time (ms) 7 or less or less or less or less or less 6 or less ir/inert gas.0 MPa 0. MPa. MPa 0 to 0 C () Non-lube () Non-locking push type (Flush) 0/0 () Dustproof (Degrees of protection 0) () 00, 00 VC, 0/60 Hz; VDC to +0% of rated voltage Class E or equivalent (0 C) (). V/0 Hz,. V/60 Hz. V/0 Hz, V/60 Hz.8 W (FZ) Non plug-in type Grommet (G), Plug connector (L, M, KZ) DIN terminal (D) Weight (kg) Note ) Use dry air at low temperatures. Note ) Use turbine oil Class (ISO VG), if lubricated. Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 8. and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Note ) ased on JIS C 090. Note ) ased on JIS C 00. Option Specifications, 8, 0, 0 VC (0/60 Hz) Coil rated voltage 6,, 8 VDC Manual override Locking type (Tool required) Option With light/surge voltage suppressor Note) Note) Plug-in, K plug connector type is standard with light/surge voltage suppressor VP S S VS N Non plug-in type -7-7

120 Series S000 8 Plug-in Light/Surge voltage suppressor Z With light/surge voltage suppressor S With surge voltage suppressor Note) With light/surge voltage suppressor is provided as standard. Electrical entry F: How to Order Nil: Non-locking push type (Flush) S 0 F Z 0 Pilot valve manual override Option Port size Nil 0 : Locking type (Tool required) Without sub-plate Rc 8 6 S Non plug-in 0 Coil rated voltage 6 9 SCZS L Series S000 pplicable model Single/ Double, side Double, side position side position side G 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC VDC Other Option Electrical entry G: Grommet Lead wire length: 00 mm H: Grommet Lead wire length: 600 mm How to Order Pilot Valve ssembly -7-8 position single position double position closed center position exhaust center position pressure center position double check Option Nil Z S L: L plug connector With lead wire M: M plug connector With lead wire KZ: K plug connector With lead wire Pilot valve assembly Coil rated voltage Electrical entry, 00 VC, 0/60 Hz Light/Surge voltage suppressor 00 VC, 0/60 Hz Electrical entry ody type 0 VC, 0/60 Hz Plug-in F Note) Plug-in 0 VC, 0/60 Hz type VDC G Grommet 6 VDC Grommet/With surge GS 9 Other voltage suppressor Option L L plug connector L plug connector, With light Manual override LZ /surge voltage suppressor Non-locking Nil M M plug connector Non plug-in push type (Flush) MZ M plug connector, With light type Locking type /surge voltage suppressor (Tool required) K Note) K plug connector Option D DZ DIN terminal DIN terminal/with light /surge voltage suppressor Note) Since F and K types are attached without lamp cover, it should be arranged separately. 0 None With light/surge voltage suppressor With surge voltage suppressor LN: L plug connector Without lead wire MN: M plug connector Without lead wire LO: L plug connector Without connector MO: M plug connector Without connector Thread type Standard Nil N Option T F KZN: K plug connector KZO: K plug connector Without lead wire Without connector How to Order Light Cover ssembly XT7- FZ S000 Light cover assembly pplicable model position single position double position closed center position exhaust center position pressure center 6 position double check Voltage 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC 6 VDC 9 Other Option Nil: Non-locking push type (Flush) Rc NPT NPTF G Note) Indicator light is not available for grommet type. With surge voltage suppressor is available for grommet type only. With light/surge voltage suppressor is provided as standard for K plug connector type. DOZ is not available. D: DIN terminal DO: DIN terminal K plug connector Light cover assembly Pilot valve manual override : Locking type (Tool required) Option Electrical entry, Light/Surge voltage suppressor Plug-in FZ With light/surge voltage suppressor Plug-in FS With surge voltage suppressor K plug connector KZ With light/surge voltage suppressor K plug connector KS With light/surge voltage suppressor

121 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 9 Cylinder Speed Chart Series S0-0 Conditions S0-0 Tube bore x Length Speed controller Silencer Series CJ Series CM Series M T060 x m S00F-06 N0- Double Check Spacer/Specifications Can hold an intermediate cylinder position for an extended time If the double check spacer with a built-in double check valve is combined, it will enable the cylinder to stop in the intermediate stroke and maintain its position for a long time without being affected by the leakage between the spools. Double check spacer verage speed (mm/s) ore size Series CJ Pressure 0. MPa Load factor 0% Stroke 60 mm Series CM Pressure 0. MPa Load factor 0% Stroke 00 mm Series M Pressure 0. MPa Load factor 0% Stroke 00 mm ø6 ø0 ø6 ø0 ø ø ø0 ø0 ø0 ø6 ø80 ø00 Double check spacer Non plug-in type Specifications Double check spacer part no. pplicable valve model Leakage (Supply pressure: 0. MPa VS000-- S0-FZ Solenoid one side de-energized Solenoid both sides de-energized (P) (P) () (R) () (R) Non plug-in type VS000-- S0- G L M KZ D (R) 00 Ncm / (R) min or less (R) 00 Ncm / (R) min or less In the case of position double check (S60), check the leakage from piping and fittings in between valve and cylinder by means of synthetic detergent solutions, and ensure that there is no such leakage found there. lso check the leakage from cylinder seal and piston seal. If there is any leakage, sometimes the cylinder, when valve is deenergized, can move without stopping at intermediate position. 0 Use as a guide for selection. Please confirm the actual conditions with SMC Sizing Program. It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. Load factor: ((Load weight x 9.8)/Theoretical force) x 00% Caution Check Valve Operating Pressure/Characteristics SUP side pressure P (MPa) Piston Cylinder side pressure (P) Operating range Perpendicular, upward actuation Horizontal actuation Check valve SUP side pressure (P) Cylinder side pressure P (MPa) The combination of S0, S0 and a double check spacer can be used as prevention of falling at the stroke end but cannot hold the intermediate position of the cylinder. VP S S VS N -7-9

122 Series S000 0 Construction position single position double Closed center Exhaust center Pressure center Component Parts No. q w e r t y Description ody Sub-plate Spool/Sleeve dapter plate End plate Piston Replacement Parts No. Description Material u i Gasket Round head combination screw NR Carbon steel o!0 Pilot valve assembly Light cover assembly Note) Refer to page position closed center/exhaust center/pressure center Material luminum die-casted luminum die-casted Stainless steel Resin Resin Resin Note Platinum silver Platinum silver lack lack This figure shows a closed center type. Sub-plate ssembly Plug-in Non plug-in Mounting bolt and gasket are not attached. : Thread type Thread Type Standard Option Nil N T F Part no. S000-P-0 S000-S-0 Rc NPT NPTF G G-S000- (Groove gasket pc., Round head combination screw pcs.) G-S000 (Gasket pc., Round head combination screw pcs.) Note) Refer to How to Order Pilot Valve ssembly on page Refer to How to Order Light Cover ssembly on page -7-8.

123 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 Plug-in position single/double, position closed center/exhaust center/pressure center/double check position single: S0-FZ-0 Manual override (Non-locking) -ø. mounting hole 00 (Lead wire length) Pilot EXH port (External pilot port) Not machined position double : S0-FZ-0 position closed center : S0-FZ-0 position exhaust center : S0-FZ-0 position pressure center: S0-FZ-0 00 (Lead wire length) ( position: ) position double check: S60-FZ-0 00 (Lead wire length) VP S S VS N Other dimensions are the same as the single type. Other dimensions are the same as the single type. -7-

124 Series S000 Non Plug-in position single G Grommet: S0- H(S)-0 Manual override (Non-locking) -ø. mounting hole L plug connector: S0-L(Z)-0 00 (Lead wire length) Other dimensions are the same as the grommet type. M plug connector: S0-M(Z)-0 00 (Lead wire length) 00 (Lead wire length) With light/ surge voltage suppressor With light/surge voltage suppressor K plug connector: S0-KZ-0 00 (Lead wire length) Other dimensions are the same as the grommet type. DIN terminal: S0-D(Z)-0 pplicable cable O.D.: ø. to 7 MX Pg7 Pilot EXH port (External pilot port) Not machined With light/surge voltage suppressor Other dimensions are the same as the grommet type. Other dimensions are the same as the grommet type.

125 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 Non Plug-in position double, position closed center/exhaust center/pressure center Grommet position double: S0- G H(S)-0 position closed center: S0- G H(S)-0 position exhaust center: S0- G H(S)-0 position pressure center: S0- G H(S)-0 ( position: ) Manual override (Non-locking) -ø. mounting hole 00 (Lead wire length) L plug connector position double: S0-L(Z)-0 position closed center: S0-L(Z)-0 position exhaust center: S0-L(Z)-0 position pressure center: S0-L(Z)-0 ( position: ) With light/surge voltage suppressor Other dimensions are the same as the grommet type. M plug connector position double: S0-M(Z)-0 position closed center: S0-M(Z)-0 position exhaust center: S0-M(Z)-0 position pressure center: S0-M(Z)-0 00 (Lead wire length) ( position: 6) With light/surge voltage suppressor 00 (Lead wire length) K plug connector position double: S0-KZ-0 position closed center: S0-KZ-0 position exhaust center: S0-KZ-0 position pressure center: S0-KZ-0 Other dimensions are the same as the grommet type. DIN terminal position double: S0-D(Z)-0 position closed center: S0-D(Z)-0 position exhaust center: S0-D(Z)-0 position pressure center: S0-D(Z)-0 pplicable cable O.D.: ø. to 7 MX.0 6. ( position: 6.) Pg7 00 (Lead wire length) Pilot EXH port 7. 7 ( position: 7.) With light/surge voltage suppressor (External pilot port) Not machined VP S S VS N Other dimensions are the same as the grommet type. Other dimensions are the same as the grommet type. -7-

126 Series S000 Non Plug-in position double check G H Grommet: S60- (S)-0 Manual override (Non-locking) -ø. mounting hole 00 (Lead wire length) L plug connector: S60-L(Z)-0 Other dimensions are the same as the grommet type. M plug connector: S60-M(Z)-0 00 (Lead wire length) With light/surge voltage suppressor With light/surge voltage suppressor 00 (Lead wire length) K plug connector: S60-KZ-0 DIN terminal: S60-D(Z)-0 MX Pg7 00 (Lead wire length) Pilot EXH port Other dimensions are the same as the grommet type. With light/surge voltage suppressor (External pilot port) Not machined pplicable cable O.D.: ø. to Other dimensions are the same as the grommet type. Other dimensions are the same as the grommet type.

127 Series S000 Manifold Specifications Plug-in Type: Stacking Type Manifold ase with D-sub Connector Refer to page -7- for wiring specifications. Wide range of interchangeability (D-sub connector (P) conforming to MIL standard) Quick wiring permits easier installation. U side D side Non Plug-in Type: Stacking Type Manifold ase Wiring for every valve VS F D 06 0 Series S000 Manifold Stacking type manifold base with D-sub connector Connector mounting direction Connector pplicable mounting position stations D D side U U side oth sides to 8 to 8 9 to 6 0 stations 6 6 stations Max. 6 stations. Max. stations. Max. stations. Port size 0 C C6 Passage (P) (R), (R) Common Common Plug-in Type: Stacking Type Manifold ase with ttachment Plug Lead Wire The insert plug is attached to the VS G 06 C6 manifold block and lead wire is plugged in with valve side. Please connect with corresponding Series S000 Manifold power side. Stacking type manifold base with attachment plug lead wire Port size M plug connector D-sub connector cable assembly VS 0 stations Series S000 Manifold Non plug-in type Stacking type manifold base stations 06 0 stations stations 0 C C6 Standard Nil N Option T F Rc 8 Embedded type One-touch fitting pplicable tubing O.D.: ø Embedded type One-touch fitting pplicable tubing O.D.: ø6 Porting specifications (), () Side Rc 8 Embedded type One-touch fitting pplicable tubing O.D.: ø Embedded type One-touch fitting pplicable tubing O.D.: ø6 Thread type Standard Nil N Option T F Passage Porting specifications (P) (R), (R) (), () Common Common Side C Port size 0 C C6 Rc 8 Embedded type One-touch fitting pplicable tubing O.D.: ø Embedded type One-touch fitting pplicable tubing O.D.: ø6 Rc NPT NPTF G Thread type Standard Nil N Option T F Passage Porting specifications (P) (R), (R) (), () Common Common Side Refer to page -7- for wiring specifications. Rc NPT NPTF G Thread type Rc NPT NPTF G VP S S VS N K plug connector -7-

128 Series S000 6 Manifold Specifications ase model VS-F VS-G Non plug-in type VS- Porting specifications Wiring (), () Port With D-sub connector With attachment plug lead wire Grommet L plug connector M plug connector K plug connector DIN terminal With attachment plug lead wire: stations max. Manifold Option Parts ssembly Individual SUP spacer n individual SUP spacer set on manifold block can form SUP port for every valve. Port size Rc (P), (R) (R) () () 8 8 C C6 to 6 stations to stations Flow Characteristics at the Number of Manifold (Operated single/double type individually) Passage/ / (P /) / / (/ R/R) ody type Part no. Rc 8 Part no. C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv VS000-P-0- pplicable solenoid valve S0-FZ G L S0- M KZ D Station Station Station 0 Station Station Non plug-in type VS000-P-0- Individual EXH spacer n individual EXH spacer set on manifold block can form EXH port for every valve. ody type Rc 8 VS000-R-0- Manifold Option Non plug-in type VS000-R-0- SUP block disk When supplying manifold with more than two different pressures, high and low, insert a block disk in between stations subjected to different pressures. ody type Part no. With control unit /Non plug-in type Filter, regulation valve, pressure switch and air release valve all combine to form one unit. Piping processes are eliminated Non plug-in type VS000-6 Side For details, refer to pages -7-9 and EXH block disk When valve exhaust affects the other stations on the circuit or when the reverse pressure valve is used to standard manifold valve, insert EXH block disk in between stations to separate valve exhaust. ody type Part no. ody type Part no. Non plug-in type VS000-6 lanking plate It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. VS Non plug-in type VS Interface regulator (P port regulation) Spacer Interface regulators can be placed on top of the manifold block to reduce the pressure of each of the valves. ody type Part no. RZS P- Non plug-in type RZS P- Note) pply pressure from the P port of the base to operate the interface regulator. To use concurrently with a double check spacer, assemble in the following order: the valve, the interface regulator, and the double check spacer. With serial interface unit for serial transmission Solenoid valve wiring process reduced considerably. Disperse installation possible. Manifold solenoid valve: stations ( point) max. Maintenance and inspection are easy. For details, refer to catalog (CT. 0-6, 7, 8, 9). How to Order Manifold ssembly Please indicate manifold base type, corresponding valve, and option parts. (Example) (t 6 stations) (Manifold base) VS-FD-06-0 ( position single) S0-FZ ( position double) S0-FZ (lanking plate) VS Non plug-in type (t 6 stations) (Manifold base) VS ( position single) S0-G ( position exhaust center) S0-G (Individual EXH spacer) VS000-R-0- Double check spacer If the double check spacer with a built-in double check valve is combined, it will enable the cylinder to stop in the intermediate stroke and maintain its position for a long time without being affected by the leakage between the spools. ody type Part no. ody type Part no. VS000-- VS With coaxial fitting /Non plug-in type Piping man-hours reduced One-touch piping / the number of tubes Non plug-in type VS000-- Throttle valve spacer Needle valve set on the manifold block can control cylinder speed by throttling exhaust. Non plug-in type VS For details, refer to catalog (CT. 0-).

129 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 7 Manifold With D-sub connector: VS-F- Station - Port size Manual override L L L L L L U side (n) () () D side D-sub connector With attachment plug lead wire: VS-G- Station - Port size U side (n) () () D side Electrical entry -ø. mounting hole Indicator light 06 -ø. mounting hole Manual override Indicator light C, C (Port size: One-touch fitting type) C, C6 9. n: Formula 7n + 9 7n + 8 (Port size: One-touch fitting type) n: Formula 7n + 9 7n VP S S VS N

130 Series S000 8 Manifold Non plug-in type VS-- Station - Port size Grommet (G) U side (n) -ø. mounting hole Manual override () () D side L Plug connector (L) Plug connector (M) L L 00 (Lead wire length) 00 (Lead wire length) position Double Single 88. With light/surge voltage suppressor: Type LZ position: 6 Double Single (Lead wire length) With light/surge voltage suppressor: Type MZ Plug connector (K) DIN terminal (D) (Lead wire length) 7 8 MX.0 position 6. Double 6. Single 9. 7 With light/surge voltage suppressor Pg (Port size: One-touch fitting type) 8 E 9 -C,C6 P position: 7. Double: 7. Single PE E n: Formula 7n + 9 7n

131 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 9 Manifold with Control Unit Control unit (Filter, Regulator, Pressure switch, ir release valve) are all standardized to the one unit, and can be mounted on the manifold base without any attachments. Piping processes are eliminated. Non plug-in type When using an air filter with auto-drain or manual override drain, mount the filter vertically. VS F Series S000 Manifold ase type/electrical entry : F Stacking type manifold base with D-sub connector : G Stacking type manifold base with attachment plug lead wire Non plug-in type: Stacking type manifold base D Connector mounting direction With connector pplicable base pplicable stations to Nil None G to D D side to 8 U U side F oth sides 9 to 6 0 stations Caution stations Note) Maximum stations F 6 stations G stations stations Passage (P) (R), (R) Common Common Manifold Specifications ase model VS-F VS-G Non plug-in type VS- Porting specifications Wiring (), () port With D-sub connector With attachment plug lead wire Grommet L plug connector M plug connector K plug connector Control Unit Specifications Side With attachment plug lead wire: stations max. ir filter (With auto-drain/with manual drain) Filtration degree 0 µm Regulator Set pressure (Outlet pressure) 0.0 to 0.7 MPa Pressure switch Set pressure range: OFF 0. to 0. MPa Differential pressure 0.08 MPa Contact a Max. switch capacity V C, W DC VC, DC or less: 0 m Max. operating current 00 VC, DC: 0 m Operating voltage 00 VC, DC or less ir release valve (Single only) Operating pressure range 0. to.0 MPa How to Order 08 0 P Porting specifications (), () Side Thread type Standard Nil Rc N NPT Option T NPTF F G Port size 0 C C6 Rc 8 Embedded type One-touch fitting pplicable tubing O.D.: ø Embedded type One-touch fitting pplicable tubing O.D.: ø6 Port size (P), (R) (R) Rc 8 () () Rc 8 C C6 to 6 stations to stations Control Unit/ Option lanking plate Filter element Pressure switch Option Control unit type pplicable valve model S0-FZ G S0- L M KZ MP- (With control unit/filter regulator) VS000- (With pressure switch) VS (Release valve) XTO VS000- Non plug-in type IS X0 Coil voltage of air release valve Nil None 00 VC, 0/60 Hz 00 VC, 0/60 Hz VDC 9 Other Note) How to take out the lead wire of air release valve is the same method as the other valve equipped on the same manifold. Control equipment Nil P M MP F G C E ir filter regulator with auto-drain ir filter regulator with manual drain ir release valve Pressure switch lanking plate (ir release valve) lanking plate (Filter regulator) lanking plate (Pressure switch) Number of manifold blocks required for mounting () Note) Operating voltage of pressure switch: 00 VC, 00 VDC or less. Please indicate manifold base type, corresponding valve, and option parts. <Example> Plug-in base type with D-sub connector (Manifold base) VS-FD-09-0-MP ( position single) S0-FZ ( position double) S0-FZ stations are needed to mount control unit. Non plug-in type (Manifold base) VS M ( position single) S0-MZ stations are needed to mount control unit. VP S S VS N -7-9

132 Series S000 0 Manifold with Control Unit, Non plug-in type Plug-in base type: VS-F- Station - Port size - Classification of control unit n-rc /8, C, C6 Example for manifold Individual EXH spacer L L L (MP) L (P) L L L (MP) L (P) Non plug-in base type: VS-- Station - Port size - Classification of control unit -7-0 U side (n) () () D side U side 00 Lead wire length (n) () () D side (Mounting hole) (Manual override) 0 Manual override 0 n-rc /8, C, C Example for manifold ir release valve ir filter regulator Control unit Control unit ir release valve ir filter regulator Double check spacer Individual SUP spacer Pressure unit Outlet for check Control unit Control unit n: Formula 7n + 9 7n +. 7n + 6. Individual EXH spacer Double check spacer Individual SUP spacer Pressure unit Outlet for check n: Formula 7n + 9 7n +. 7n + 6.

133 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 Manifold Option Parts Individual SUP spacer : VS000-P-0- Non plug-in type: VS-000-P-0-, Non plug-in type Double check spacer : VS000-- Non plug-in type: VS000-- Individual SUP spacer Double check spacer SUP port Individual EXH spacer : VS000-R-0- Non plug-in type: VS000-R-0- Individual EXH spacer EXH port SUP block disk : VS000-6 EXH blocking plate lock disk Throttle valve spacer : VS Non plug-in type: VS Throttle valve spacer VP S S VS N ( ): Plug-in base type -7-

134 Series S000 Exploded View of Manifold Non plug-in type Type Description Manifold block assembly Plug-in type Type F pplicable manifold base With attachment plug lead wire: Type G Non plug-in type: Type With D-sub connector: Type F ssembly part no. Replacement Parts No. q w e r t y VS000---Port size () VS000---Port size () VS000---Port size () (-) () Description Material Seal NR Seal NR O-ring NR O-ring NR Tie-rod Carbon steel Tie-rod for station addition Carbon steel Note ) n: Note ) Manifold block assembly is attached with tie-rod for increasing stations. Part no. VS000-- VS000-. x x. 7. x. x. VS000--n () VS () Component parts Manifold block u, Junction box i, Lead wire assembly o Tie-rod y, O-ring e, r, Seal q Manifold block u, Tie-rod y, O ring e, r, Seal q Note ) ore-0: Rc / 8, -C: Embedded type One-touch fitting for ø, -C6: Embedded type One-touch fitting for ø6. Note ) Refer to page -7- for the model of D-sub connector type manifold block assembly. How to Increase Manifold ase rrange an applied manifold block assembly. Plug-in type Type G. Loosen the bolt! and remove the end plate! or! in the side added with manifold block.. Joint the tie-rod y to increase stations and add manifold block assembly. (Put packing w on the surface contacting to the end plate.). For a style with a D-sub connector, open the cover! and insert the pin of lead wire assembly!0 as shown in the right figure Mount the end plate! and! and tighten the bolt!. Note ) e careful that the packing and the O-ring do not fall out of the groove. Note ) The tightening torque of bolt! should be to. N. Red White lack Lead wire ass y Manifold block u, Junction box i, Lead wire assembly!0 Tie-rod y, O-ring e, r, Seal q Insertion Method for Pin of D-Sub Connector D-sub connector Pin Confirm an insertion of the lead (n) wire ass y after the insertion of pin () by light pulling of the lead wire. () Note ) Regardless of the D-sub connector mounting position, stations are to be counted from D side as the st one. Note ) D-sub connector can use up to 8 stations in on side fitting (Type F D U). More than 9 stations are for both sides fitting (Type F). D-sub connector terminal no. Unused U side D side station (9 stations) stations (0 stations) stations ( stations) stations ( stations) stations ( stations) 6 stations ( stations) 7 stations ( stations) 8 stations (Max. 6 stations) Lead wire Terminal no. color lack White Red lack White Red lack White Red lack White Red lack White Red lack White Red lack White Red lack White Red ( ) is for the case of a D-sub connector for both sides (Type F).

135 For details about certified products conforming to international standards, visit us at Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 Model Type of actuation position position Single Double S Closed center S Exhaust center S Pressure center S Double check S60.. Note ) Min. operating cycle is based on JIS 87 (One time per 0 days). Note ) Response time is based on JIS (0. MPa, without light/surge voltage suppressor) Note ) For S0-FZ-0 Note ) Note and Note are with controlled clean air. Reduction of wiring cost MIL standard D-sub connector with one-touch connection () Compact and large valve capacity: Width 8 mm Flexible to increase and decrease manifold stations (Stacking type manifold base) High frequency/long service life (more than 0 mil. times) Possible to use in nonlubrication and dry air (Metal seal structure) Different variations for connection Grommet type L, M plug connector type: Individual take out of and sides K plug connector type: Common take out of and sides DIN terminal type: Individual take out of and sides little power consumption:.8 W DC For serial transmission Model S0 Port size Rc Flow characteristics / (P /) / / (/ R/R) C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv Standard Specifications Valve specifications Electricity specifications Option Specifications Fluid Maximum operating pressure Minimum operating pressure Proof pressure mbient and fluid temperature Lubrication Pilot valve manual override Shock/Vibration resistance (m/s ) Enclosure Coil rated voltage llowable voltage fluctuation Coil insulation type Inrush pparent power (C) Holding Power consumption (DC) Electrical entry 0. () Max. operating cycle (CPM) or less or less 6 or less 6 or less 6 or less or less ir/inert gas.0 MPa 0. MPa. MPa 0 to 0 C () Non-lube () Non-locking push type (Flush) 0/0 () Dustproof (Degrees of protection 0) () 00, 00 VC, 0/60 Hz; VDC to +0% of rated voltage Class E or equivalent (0 C) (). V/0 Hz,. V/60 Hz. V/0 Hz, V/60 Hz.8 W (FZ) Non plug-in type Grommet (G), Plug connector (L, M, KZ) DIN terminal (D) Note ) Use dry air at low temperatures. Note ) Use turbine oil Class (ISO VG), if lubricated. Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 8. and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Note ) ased on JIS C 090. Note ) ased on JIS C 00., 8, 0, 0 VC (0/60 Hz) Coil rated voltage 6,, 8 VDC Manual override Locking type (Tool required) Option With light/surge voltage suppressor Note) Note) Plug-in, K plug connector type is standard with light/surge voltage suppressor. () Response time (ms) () Weight (kg) VP S S VS N Non plug-in type -7-

136 Series S000 How to Order Light/Surge voltage suppressor Z S With light/surge voltage suppressor With surge voltage suppressor Note) Light/Surge voltage suppressor is provided as standard. Pilot valve manual override Nil: Non-locking push type (Flush) : Locking type (Tool required) Plug-in Electrical entry F: Plug-in Option S 0 F Z 0 Port size Nil Without sub-plate 0 Rc 8 0 Rc SCZS L Series S000 pplicable model Single/ Double side Double side position side position side 6 Electrical entry, Light/Surge voltage suppressor F Note) G GS L LZ M MZ K Note) D DZ S Non plug-in position single position double position closed center position exhaust center position pressure center position double check Electrical entry Plug-in Grommet Grommet, With surge voltage suppressor L plug connector L plug connector, With light /surge voltage suppressor M plug connector M plug connector, With light /surge voltage suppressor K plug connector DIN terminal DIN terminal, With light /surge voltage suppressor 0 Coil rated voltage 6 9 Option ody type Plug-in type Non plug-in type Note) Since F and K types are attached without lamp cover, it should be arranged separately. 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC 6 VDC 9 Other Option Manual override Nil Pilot valve assembly Coil rated voltage Option G 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC VDC Other Non-locking push type (Flush) Option Nil Z S G: Grommet L: L plug connector Lead wire length With lead wire 00 mm H: Grommet Lead wire length 600 mm How to Order Pilot Valve ssembly -7- M: M plug connector With lead wire KZ: K plug connector With lead wire Locking type (Tool required) 0 None With light/surge voltage suppressor With surge voltage suppressor Thread type Standard Option Nil N T F Rc NPT NPTF G Note) Indicator light is not available for grommet type. With light/surge voltage suppresser is provided as standard for K plug connector type. DOZ is not available. Electrical entry LN: L plug connector Without lead wire MN: M plug connector Without lead wire KZN: K plug connector Without lead wire LO: L plug connector Without connector MO: M plug connector Without connector KZO: K plug connector Without connector How to Order Light Cover ssembly XT7- FZ S000 Light cover assembly pplicable model position single position double position closed center position exhaust center position pressure center 6 position double check 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC 6 VDC 9 Other Option Voltage D: DIN terminal DO: DIN terminal Pilot valve manual override Nil: Non-locking : Locking type push type (Tool required) (Flush) Option Electrical entry, Light/Surge voltage suppressor FZ FS KZ KS K plug connector Light cover assembly Plug-in With light/surge voltage suppressor Plug-in With surge voltage suppressor K plug connector With light/surge voltage suppressor K plug connector With light/surge voltage suppressor

137 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 Cylinder Speed Chart Series S0-0 Conditions S0-0 verage speed (mm/s) Use as a guide for selection. Please confirm the actual conditions with SMC Sizing Program. ore size Series CJ Pressure 0. MPa Load factor 0% Stroke 60 mm Series CM Pressure 0. MPa Load factor 0% Stroke 00 mm Series M Pressure 0. MPa Load factor 0% Stroke 00 mm ø6 ø0 ø6 ø0 ø ø ø0 ø0 ø0 ø6 ø80 ø00 It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. Load factor: ((Load weight x 9.8)/Theoretical force) x 00% Series CJ Series CM Series M Tube bore x Length T060 x m T0806 x m Speed controller S00F-06 S00F-08 Silencer N0-0 Double Check Spacer/Specifications Can hold an intermediate cylinder position for an extended time If the double check spacer with a built-in double check valve is combined, it will enable the cylinder to stop in the intermediate stroke and maintain its position for a long time without being affected by the leakage between the spools. Double check spacer Double check spacer Non plug-in type Specifications Double check spacer part no. pplicable valve model Leakage 0. MPa VS000-- S0-FZ Solenoid one side energized Solenoid both sides energized (P) (P) () (R) () (R) Non plug-in type VS000-- S0- G L M KZ D (R) 0 Ncm / (R) min or less (R) 0 Ncm / (R) min or less Caution In the case of position double check (S60), check the leakage from piping and fittings in between valve and cylinder by means of synthetic detergent solutions, and ensure that there is no such leakage found there. lso check the leakage from cylinder seal and piston seal. If there is any leakage, sometimes the cylinder, when valve is de-energized, can move without stopping at intermediate position. 0 Check Valve Operating Pressure/Characteristics SUP side pressure P (MPa) Piston Cylinder side pressure Operating range Perpendicular, upward actuation Horizontal actuation Check valve SUP side pressure P Cylinder side pressure P (MPa) The combination of S0, S0 and a double check spacer can be used as prevention of falling at the stroke end but cannot hold the intermediate position of the cylinder. VP S S VS N -7-

138 Series S000 6 Construction position single position double Closed center Exhaust center Pressure center Component Parts No. q w e r t y Description ody Sub-plate Spool/Sleeve dapter plate End plate Piston Replacement Parts position closed center/exhaust center/pressure center Material luminum die-casted luminum die-casted Stainless steel Resin Resin Resin Note Platinum silver Platinum silver lack lack This figure shows a closed center type. Sub-plate ssembly Plug-in Non plug-in 0 S000-P- 0 0 S000-S- Mounting bolt and gasket are not attached. : Thread type Thread Type Standard Nil Rc N NPT Option T NPTF F G No. Description Material Part no. u i Gasket Round head combination screw NR Carbon steel G-S000- (Groove gasket pc. Round head combination screw pcs.) G-S000 (Gasket pc., Round head combination screw pcs.) Note) o!0 Pilot valve assembly Light cover assembly Refer to How to Order Pilot Valve ssembly on page -7-. Refer to How to Order Light Cover ssembly on page -7-. Note) Refer to page

139 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 7 Plug-in position single/double, position closed center/exhaust center/pressure center/double check position single: S0-FZ- 0 0 Manual override (Non-locking) -ø. mounting hole 00 (Lead wire length) position double: S0-FZ- 0 0 position closed center: S0-FZ- position exhaust center: S0-FZ- position pressure center: S0-FZ- 00 (Lead wire length) 9. ( position: 7) Other dimensions are the same as the single type. 0 -Rc /8, / Pilot EXH port position double check: S60-FZ (Lead wire length) Other dimensions are the same as the single type. (External pilot port) Not machined ( ): Rc /8 VP S S VS N -7-7

140 Series S000 8 Non Plug-in position single G H Grommet: S0- (S)- 0 0 Manual override (Non-locking) -ø. mounting hole L plug connector: S0-L(Z) (Lead wire length) Other dimensions are the same as the grommet type. M plug connector: S0-M(Z) (Lead wire length) 00 (Lead wire length) -Rc /8, / With light/surge voltage suppressor With light/surge voltage suppressor K plug connector: S0-KZ (Lead wire length) Other dimensions are the same as the grommet type. DIN terminal: S0-D(Z)- 0 MX.0 pplicable cable O.D. ø. to ø7 78 Pg7 Pilot EXH port (External pilot port) Not machined With light/surge voltage suppressor ( ): Rc / Other dimensions are the same as the grommet type. Other dimensions are the same as the grommet type.

141 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 9 Non Plug-in position double, position closed center/exhaust center/pressure center Grommet G position double: S0- (S)- 0 G H 0 position closed center: S0- H(S)- 0 0 G position exhaust center: S0- (S)- 0 G 0 position pressure center: S0- (S)- 0 0 H 9. ( position: 7) H 00 (Lead wire length) L plug connector position double: S0-L(Z)- 0 0 position closed center: S0-L(Z)- 0 0 position exhaust center: S0-L(Z)- 0 0 position pressure center: S0-L(Z)- 0 0 Other dimensions are the same as the grommet type. M plug connector position double: S0-M(Z) ø. mounting hole position closed center: S0-M(Z)- 0 0 position exhaust center: S0-M(Z)- 0 0 position pressure center: S0-M(Z) (Lead wire length) 9. ( position: 7) With light/surge voltage suppressor 68. ( position: 76) With light/surge voltage suppressor -Rc /8, / 00 (Lead wire length) K plug connector position double: S0-KZ- 0 0 position closed center: S0-KZ- 0 0 position exhaust center: S0-KZ- 0 0 position pressure center: S0-KZ (Lead wire length) DIN terminal position double: S0-D(Z)- 0 0 position closed center: S0-D(Z)- 0 0 position exhaust center: S0-D(Z)- 0 0 position pressure center: S0-D(Z)- 0 0 MX.0 6 ( position: 7.) pplicable cable O.D. ø. to ø7 Pg7 Manual override (Non-locking) Pilot EXH port (External pilot port) Not machined 66 ( position: 7.) Other dimensions are the same as the grommet type. 79 With light/surge voltage suppressor ( ): Rc / VP S S VS N Other dimensions are the same as the grommet type. Other dimensions are the same as the grommet type. -7-9

142 Series S000 0 Non Plug-in position double check G H Grommet: S60- (S) ø. mounting hole Manual override (Non-locking) 00 (Lead wire length) L plug connector: S60-L(Z)- 0 0 K plug connector: S60-KZ- 0 0 Other dimensions are the same as the grommet type. M plug connector: S60-M(Z) (Lead wire length) With light/surge voltage suppressor With light/surge voltage suppressor 00 (Lead wire length) -Rc /8, / 00 (Lead wire length) Pilot EXH port Other dimensions are the same as the grommet type. DIN terminal: S60-D(Z) MX.0 79 pplicable cable O.D. With light/surge voltage suppressor ø. to ø7 Pg7 (External pilot port) Not machined ( ): Rc / Other dimensions are the same as the grommet type. Other dimensions are the same as the grommet type. -7-0

143 Series S000 Manifold Specifications Plug-in Type: Stacking Type Manifold ase with D-sub Connector Refer to page -7- for wiring specifications. Wide range of interchangeability (D-sub connector (P) conforming to MIL standard) Quick wiring permits easier installation. U side Wiring for every valve VS F D 06 0 Series S000 Manifold Stacking type manifold base with D-sub connector Connector mounting direction Connector pplicable mounting position stations D U D side U side oth sides The insert plug is attached to VS the manifold block and lead wire is plugged in with valve side. Please connect with Series S000 Manifold corresponding power side. Stacking type manifold base with attachment plug lead wire VS to 8 to 8 9 to 6 0 stations 6 6 stations Max. 6 stations. G 06 0 stations Series S000 Manifold Non plug-in type Stacking type manifold base stations Max. stations stations stations Max. stations. Port size Thread type Standard Nil N Option T F 0 Rc 8 0 Rc C6 C8 Embedded type One-touch fitting pplicable tubing O.D.: ø6 Embedded type One-touch fitting pplicable tubing O.D.: ø8 Passage Porting specifications (P) (R), (R) (), () Common Common Side Plug-in Type: Stacking Type Manifold ase with ttachment Plug Lead Wire Non Plug-in Type: Stacking Type Manifold ase M plug connector D side K plug connector D-sub connector cable assembly C6 Port size 0 0 C6 C8 Passage (P) (R), (R) Common Common C8 Port size 0 0 C6 C8 Passage (P) (R), (R) Common Common Rc 8 Standard Nil N Option T F Rc Embedded type One-touch fitting pplicable tubing O.D.: ø6 Embedded type One-touch fitting pplicable tubing O.D.: ø8 Rc 8 Porting specifications (), () Side Rc NPT NPTF G Thread type Thread type Standard Nil N Option T F Rc Embedded type One-touch fitting pplicable tubing O.D.: ø6 Embedded type One-touch fitting pplicable tubing O.D.: ø8 Porting specifications (), () Side Refer to page -7- for wiring specifications. Rc NPT NPTF G Rc NPT NPTF G -7- VP S S VS N

144 Series S000 Manifold Specifications ase model VS-F VS-G Non plug-in type VS- Porting specifications Wiring (), () Port With D-sub connector With attachment plug lead wire Grommet L plug connector M plug connector K plug connector DIN terminal Flow Characteristics at the Number of Manifold (Operated single/double type individually) Passage/ / (P /) / / (/ R/R) C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv Individual SUP spacer n individual SUP spacer set on manifold block can form SUP port for every valve. Individual EXH spacer n individual EXH spacer set on manifold block can form EXH port for every valve. With control unit Plug-in base type/non plug-in base type Filter, regulation valve, pressure switch and air release valve all combine to form one unit. Piping processes are eliminated. Side Manifold Option Parts ssembly Port size Rc (P), (R) () (R) () 8, C C6 to 6 stations to stations pplicable valve model S0-FZ G L S0- M KZ D Station Station Station 0 Station Station SUP block disk When supplying manifold with more than two different pressures, high and low, insert a block disk in between stations subjected to different pressures. ody type Part Rc 8 VS000-P-0- Non plug-in type VS000-P-0- no. Rc VS000-P-0- VS000-P-0- ody type Non plug-in type Part no. XT6- ody type Part no. Rc With attachment plug lead wire teminal: stations max. VS000-R-0- Manifold Option Non plug-in type VS000-R-0- EXH block disk When valve exhaust affects the other stations on the circuit or when the reverse pressure valve is used to standard manifold valve, insert EXH block disk in between stations to separate valve exhaust. ody type Part no. Non plug-in type XT6- Interface regulator (P port regulation) Spacer Interface regulators can be placed on top of the manifold block to reduce the pressure of each of the valves. ody type Part no. RZS P- Non plug-in type RZS P- Note) pply pressure from the P port of the base to operate the interface regulator. To use concurrently with a double check spacer, assemble in the following order: the valve, the interface regulator, and the double check spacer. With serial interface unit for serial transmission Plug-in base type Solenoid valve wiring process reduced considerably. Disperse installation possible. Manifold solenoid valve: stations ( points) max. Maintenance and inspection are easy. How to Order Manifold ssembly Please indicate manifold base type, corresponding valve, and option parts. (Example) (t 6 stations) (Manifold base) VS-FD-06-0 ( position single) S0-FZ ( position double) S0-FZ (lanking plate) VS Non plug-in type (t 6 stations) (Manifold base) VS ( position single) S0-G ( position exhaust center) S0-G (Individual EXH spacer) VS000-R-0- Double check spacer If the double check spacer with a built-in double check valve is combined, it will enable the cylinder to stop in the intermediate stroke and maintain its position for a long time without being affected by the leakage between the spools. ody type Part no. VS000-- Non plug-in type VS000-- lanking plate It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. ody type Part no. VS Non plug-in type VS With coaxial fitting Plug-in base type/non plug-in base type Piping man-hours reduced One-touch piping / the number of tubes For details, refer to pages -7- and For details, please contact SMC. For details, please contact SMC. -7-

145 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 Manifold With D-sub connector: VS-F- Station - Port size L L L L L L U side Insert plug with lead wire: VS-G- Station - Port size (n) () () D side D-sub connector U side (n) () () D side (Electrical entry) -ø. mounting hole Manual override Indicator light ø. mounting hole Manual override Indicator light C6, C (Port size: One-touch fitting type) n-rc /8, / C6, C8 0.7 n: Formula 0n + 0n + 0 (Port size: One-touch fitting type) n: Formula 0n + 0n VP S S VS N

146 Series S000 Manifold Non plug-in type VS-- Station - Port size Grommet (G) Manual override U side (n) -ø. mounting hole n-rc /8, / () () D side L Plug connector (L) L L 00 (Lead wire length) Plug connector (M) 00 (Lead wire length) postion 7 Double 9. Single 99 With light/surge voltage suppressor With light/surge voltage suppressor position 76 Double 68. Single (Lead wire length) MX Pg C6, C (Port size: One-touch fitting type) Plug connector (K) 00 (Lead wire length) DIN terminal (D) position 7. Double 6 Single. position 7. Double 6 Single 06 With light/surge voltage suppressor E P PE E n: Formula 0n + 0n

147 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 Manifold with Control Unit Control unit (Filter, Regulator, Pressure switch, ir release valve) are all standardized in the one unit, and can be mounted on the manifold base without any attachments. Piping processes are eliminated. VS Non plug-in type F Series S000 Manifold ase type/electrical entry : F Stacking type manifold base with D-sub connector : G Stacking type manifold base with attachment plug lead wire Non plug-in type: Stacking type manifold base D Connector mounting direction With connector pplicable base pplicable stations to Nil None G to D D side to 8 U U side F oth sides 9 to 6 0 stations Caution When using an air filter with auto-drain or manual override drain, mount the filter vertically. stations Note) Maximum stations F 6 stations G stations stations Passage (P) (R), (R) Common Common Manifold Specifications ase model VS-F VS-G Non plug-in type VS- Wiring With D-sub connector With attachment plug lead wire Porting specifications Port size, port P, E, E, Rc 8, Grommet L plug connector M plug connector K plug connector Side Rc C6 C8 Control Unit Specifications ir filter (With auto-drain/with manual drain) Filtration degree µm Regulator Set pressure (Outlet pressure) 0.0 to 0.8 MPa Pressure switch Set pressure range: OFF 0. to 0. MPa Differential pressure 0.08 MPa Contact a Max. switch capacity V C, W DC VC, DC or less: 0 m Max. operating current 00 VC, DC: 0 m Operating voltage 00 VC, DC or less ir release valve (Single only) Operating pressure range 0. to.0 MPa 08 0 P Porting specifications (), () Side With attachment plug lead wire: stations max. How to Order Standard Nil N Option T F Port size 0 Rc 8 0 Rc C6 Embedded type One-touch fitting pplicable tubing O.D.: ø6 C8 Thread type Rc NPT NPTF G Embedded type One-touch fitting pplicable tubing O.D.: ø8 to 6 stations to stations Control Unit/ Option lanking plate Filter element Pressure switch pplicable valve model S0-FZ G S0- L M KZ MP- (With control unit/filter regulator) VS000- (With pressure switch) VS (Release valve) - VS000- Non plug-in type IS X0 Coil voltage of air release valve Nil None Note) How to take out 00 VC, 0/60 Hz the lead wire of air 00 VC, 0/60 Hz release valve is the VDC same method as 9 Other the other valve equipped on the Option same manifold. Control unit types Control equipment Nil ir filter regulator with auto-drain ir filter regulator with manual drain ir release valve Pressure switch lanking plate (ir release valve) lanking plate (Filter regulator) lanking plate (Pressure switch) Number of manifold blocks required for mounting () P M MP F G C E Note) Operating voltage of pressure switch: 00 VC, 00 VDC or less. Please indicate manifold base type, corresponding valve, and option parts. <Example> with D-sub connector (Manifold base) VS-FD-09-0-MP ( position single) S0-FZ ( position double) S0-FZ stations are needed to mount control unit. Non plug-in type (Manifold base) VS M ( position single) S0-G stations are needed to mount control unit. VP S S VS N -7-

148 Series S000 6 Manifold with Control Unit, Non plug-in type VS-F- Station - Port size - Classification of control unit -ø. mounting hole U side (n) Manual override Indicator light n-rc /8, /, C6, C8 Example for manifold Individual EXH spacer Double check spacer Individual SUP spacer () () D side L L L (MP) L (P) Non plug-in type VS-- Station - Port size - Classification of control unit U side 00 Lead wire length (n) () () D side Drain cock Filter element n-rc /8, /, C6, C8 Example for manifold L L L (MP) L (P) Filter element Drain cock Manual override Indicator light ir release valve ir filter regulator Control unit Control unit ir release valve ir filter regulator Control unit Pressure unit Outlet for check Control unit n: Formula 0n + 0n n +. Individual EXH spacer Double check spacer Individual SUP spacer Pressure unit Outlet for check n: Formula 0n + 0n n +.

149 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 7 Manifold Option Parts, Non plug-in type Individual SUP spacer 0 : VS000-P- 0-0 Non plug-in type: VS000-P- - 0 SUP block disk : XT6- EXH blocking plate Individual SUP spacer lock plate RC /8, / SUP port Individual EXH spacer : VS000-R-0- Non plug-in type: VS000-R-0- Individual EXH spacer EXH port Double check spacer : VS000-- Non-plug-in type: VS000-- Double check spacer ( ): VP S S VS N -7-7

150 Series S000 8 Exploded View of Manifold Non plug-in type Type Plug-in type Type F Description Manifold block assembly pplicable manifold base With attachment plug lead wire: Type G Non plug-in base type: Type With D-sub connector: Type F Plug-in type Type G rrange an applied manifold block assembly.. Loosen the bolt! and remove the end plate! or! in the side added with manifold block. ssembly part no. VS000---Port size () VS000---Port size (). Joint the tie-rod y to increase stations and add manifold block assembly. (Put packing w on the surface contacting to the end plate.). For a style with a D-sub connector, open the cover! and insert the pin of lead wire assembly!0 as shown in the right figure.. Mount the end plate! and! and tighten the bolt!. Note ) e careful that the packing and the O-ring do not fall out of the groove. Note ) The tightening torque of bolt! should be to. N. Replacement Parts No. q w e r t y Description Material Seal NR Seal NR O-ring NR O-ring NR Tie-rod Carbon steel Tie-rod for station addition Carbon steel Part no. VS000-- VS x x. 7. x. x. VS000--n () VS () Note ) n: Note ) Manifold block assembly is attached with tie-rod for increasing stations. Component parts Manifold block u, Junction box i, Lead wire assembly o Tie-rod y, O-ring e, r, Seal q Manifold block u, Tie-rod y, O-ring e, r, Seal q Manifold block u, Junction box i, Lead wire assembly!0 Tie-rod y, O-ring e, r, Seal q Note ) ore -0: Rc / 8, -C6: Embedded type One-touch fitting for ø6, -C8: Embedded type One-touch fitting for ø8. Note ) Refer to page -7- for the model of D-sub connector type manifold block assembly. How to Increase Manifold ase -7-8 VS000---Port size () (-) () Insertion Method for Pin of D-Sub Connector Red White Lead wire ass y lack D-sub connector Pin Confirm an insertion of the lead (n) wire assembly after the insertion of pin by light pulling () of the lead wire. () Note ) Regardless of the D-sub connector mounting position, stations are to be counted from D side as the st one. Note ) D-sub connector can use up to 8 stations in on side fitting (Type F D U ). More than 9 stations are for both sides fitting (Type F). D-sub connector terminal no. Unused U side station (9 stations) stations (0 stations) stations ( stations) stations ( stations) stations ( stations) 6 stations ( stations) 7 stations ( stations) 8 stations (Max. 6 stations) D side Terminal Lead wire no. color lack White Red lack White Red lack White Red lack White Red lack White Red lack White Red lack White Red lack White Red ( ) is for the case of a D-sub connector for both sides (Type F).

151 Series Variations ody Ported ase Mounted Series S000 S000 S000 S000 Non plug-in type S000 Non plug-in type S000 Non plug-in type S000 Non plug-in type S6000 Non plug-in type Single Double Port Pilot Operated Solenoid Valve Metal Seal Series S Sonic conductance C [dm /s bar)] / /(/ R/R) position Type of actuation position single position double position closed center position exhaust center position pressure center position single position double position closed center position exhaust center position pressure center position double check position single position double Voltage Electrical entry With light/surge voltage suppressor (Option) (Standard) 00 VC, 0/60 Hz 00 VC, 0/60 Hz VDC (Option) 0 to 0 VC, 0/60 Hz 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC 00 VDC (Standard) 00 VC, 0/60 Hz 00 VC, 0/60 Hz VDC (Option) 0 to 0 VC, 0/60 Hz 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC 00 VDC Grommet (G) Conduit terminal (T) Conduit terminal (F) Non plug-in Grommet terminal (E) Plug-in Conduit terminal (F) Non plug-in Grommet terminal (E) DIN terminal (D) With light/surge voltage suppressor Grommet terminal (EZ) Conduit terminal (TZ) DIN terminal (DZ) With surge voltage suppressor Grommet (GS) Note) Indicator light is not available for grommet type. Only surge voltage suppressor can be equipped on the middle of lead wire. With light/surge voltage suppressor Manual override Non-locking push type (Flush) Non-locking push type (Extended) Locking type (Tool required) Locking type (Lever) Locking type (lever) is not available for body ported Series S000/000. Grommet (G) Conduit terminal (T) Plug-in Plug-in Conduit terminal (F) Non plug-in Grommet terminal (E) Grommet terminal (E) DIN terminal (D) DIN terminal (D) DIN terminal (D) With light/surge voltage suppressor Conduit terminal (FZ) Non plug-in type Grommet terminal (EZ) Conduit terminal (TZ) DIN terminal (DZ) With surge voltage suppressor Non plug-in type Grommet (GS) Note) Indicator light is not available for grommet type. Only surge voltage suppressor can be equipped on the middle of lead wire. Conduit terminal (FZ) Non plug-in type Grommet terminal (EZ) DIN terminal (DZ) Non-locking push type (Flush) Non-locking push type (Extended) Locking type (Tool required) Locking type (Lever) Non-locking push type (Flush) VP S S VS N -8-

152 Series S000/000/000/000/000/6000 Manifold Variations Manifold ar base Stacking base With attachment plug lead wire With terminal block With multiconnector With D-sub connector Non plug-in (Connection to each valve) ody Ported S000 S000 S000 ase Mounted Plug-in Type ase Mounted Non Plug-in Type S000 S000 S000 S000 S000 S000 S000 S000 ar ase (Series S000/000) Pilot individual EXH Pilot common EXH Stacking base (Series S000) Pilot common EXH Plug-in With attachment plug lead wire With multi-connector Non Plug-in Grommet terminal With terminal block With D-sub connector DIN terminal ottom piping is available as an option. -8-

153 Series S000/000/000/000/000/6000 With exhaust cleaner Manifold Option With control unit With serial transmission unit Individual SUP spacer Individual EXH spacer SUP block disk Manifold Option Parts EXH block disk Throttle valve spacer Interface ir shutoff regulator valve spacer ir release valve spacer Double check spacer lanking plate Note) Note) Note) Note) With exhaust cleaner With control unit With serial transmission unit Individual SUP spacer Individual EXH spacer SUP/EXH block disk Throttle valve spacer Interface regulator ir shutoff valve spacer ir release valve spacer Double check spacer VP S S VS N Note) vailable -8-

154 Series S000/000/000/000/000/6000 Precautions e sure to read before handling. For Safety Instructions and Solenoid Valve Precautions, refer to page --. Caution Light/Surge Voltage Suppressor, Electrical Entry Single unit ody Ported Series S000/000/000 Light/Surge Voltage Suppressor C and 00 VDC With indicator light Terminal no. (+) Single Terminal no. ( ) side Terminal no. (+) With indicator light side ase Mounted Light/Surge Voltage Suppressor In the case of surge voltage suppressor, surge voltage absorption device ZNR is attached to C power. C and 00 VDC With indicator light Lead wire, red Single Series S000 Exchange of pilot valve (Voltage exchange) When changing rated voltage and electrical entry etc., pilot valve assembly can be changed since this is a plug-in type. Pilot valve assembly Pilot valve assembly Double Terminal no. ( ) Terminal no. ( ) VDC or less With indicator light Terminal no. +( ) Single Terminal no. (+) Note) There is no polarity (+, ). side Terminal no. +( ) With indicator light Terminal no. +( ) side Double Terminal no. (+) With indicator light Note) There is no polarity (+, ). Terminal no. (+) Type G: Lead wire comes directly from the solenoid part. Connect it with the power source. Grommet with DC voltage surge voltage suppressor has polarity. Connect red lead wire to + (positive) side and black to (negative) side. Surge voltage suppressor DC C Wiring In the case of DIN terminal and terminal block (with indicator light/surge voltage suppressor), the interior wiring is shown below. With DIN terminal block Red + lack With terminal block ZNR pplicable terminal:.-,.-s,.y-n,.y-s, but in the case of with DIN terminal block, is not a terminal structure. Note) There is no polarity. Changing Direction of DIN Terminal/Cable Entry To change direction of DIN terminal retaining screw, pull off outer cover, rotate connector board through 80. Replace cover and tighten screw. Changing Direction of Electrical Entry and Manual Override Loosen the set screw (M pcs.), take out pilot operator, turn solenoid valve 80 degrees to change the direction of lead wire and manual override. (Possible on Series S000 only.) Double VDC or less Single Double Type G: Use lead wire from solenoid to connect with power side. Grommet with DC voltage surge voltage suppressor has polarity. Connect red lead wire to + (positive) side and black to (negative) side. Surge voltage suppressor DC C lack side lead wire, brown White Terminal no. +( ) lack With indicator light Terminal no. (+) Note) There is no polarity (+, ). Non plug-in type How to Exchange With indicator light Red side side terminal no. +( ) With indicator light Terminal no. +( ) side Terminal no. (+) Note) There is no polarity (+, ). With light/surge voltage suppressor Red + lack With light/surge voltage suppressor With indicator light Terminal no. (+) ZNR Solenoid valve Loosen set screws (hexagonal socket head cap screw M x ) and pull solenoid valve out vertically, otherwise it may cause damage to the solenoid valve. Never remove a valve at an angle. When mounting solenoid valve onto the base, plug pin assembly (base side) into receptacle Receptacle assembly assembly (body-side) vertically. Electrical Connection Single unit/ sub-plate: T Conduit terminal (With terminal block) If the junction cover () of the sub-plate is removed, you can see the plug-in type terminal block () (part no. N ) mounted inside the sub-plate. The following markings are on the terminal block board. Connect with corresponding power side. Description Solenoid side Solenoid side Terminal block marking There is no polarity. When ground wiring and COM wiring are required, please specify separately. pplicable terminal:.-,.-s,.y- N,.Y-S Single unit/non plug-in type sub-plate: G, E, T, D Type G: Use lead wire from solenoid to connect with power side. Type E, T, D: In the case of a DIN terminal and terminal block (with light/surge voltage suppressor), the interior wiring is shown below. Connect with corresponding power side. With DIN terminal block With terminal block () () Note) There is no polarity. pplicable terminal:.-,.-s,.y-n,.y-s, but in the case of with DIN connector board, is not a terminal structure. Tightening torque for terminal: 0.6 N m Changing Direction of DIN Terminal/Cable Entry Change of the electrical entry of DIN type connector cable Unscrew retaining screw, pull off outer cover, rotate connector board through 80. Replace cover and tighten screw. pplicable cable: O.D. ø6 to ø Manual position

155 Series S000/000/000/000/000/6000 Caution ase Mounted Light/Surge Voltage Suppressor, Electrical Entry Series S000/000/000/6000 Single unit Light/Surge Voltage Suppressor In the case of surge voltage suppressor, surge voltage absorption element is attached to terminal block on body area. Light/Surge voltage absorption element S000/000/000 Pilot cover Pilot valve assembly C and 00 VDC or more SOL VDC or less SOL With indicator light With indicator light Note) There is no polarity. Light/Surge Voltage Suppressor Substrate Part No. S000 S000 S000 S6000 How to Exchange Solenoid valve Loosen set screw and take solenoid valve out vertically, otherwise it may cause damage to the solenoid valve. Never remove a valve at an angle. When mounting solenoid valve onto the base, plug pin assembly (base side) into receptacle assembly (body side) vertically. Pilot valve When changing the rated voltage, electrical entry, etc., pilot valve assembly can be exchanged easily since this is plug-in type. Then, when changing the rated voltage with indicator light/surge voltage suppressor, change of indicator light/surge voltage suppressor substrate is also needed. So, order together with pilot valve assembly. Mounting screw S6000 S XT : Coil rated voltage DIN terminal block type Male pin terminal of DIN terminal block board of solenoid valve and wires as shown below. Connect to corresponding terminal block on the connector. DIN terminal (Wiring) There is no polarity. Single Double VDC or less Single Double Ground C and 00 VDC or more side side COM Ground With indicator light With indicator light With indicator light With indicator light Heavy-duty cord pplicable cable O. D.: ø8 to ø0 pplicable terminal pplicable terminal on block board: (kinds).y-l,.-.s,.-m Connector/Clamping torque Set screw 0.6 N m Terminal screw 0.6 N m Incorrect common (DIN terminal no. ) causes damage on power side circuit. Lead Wire Connection (With terminal) If the junction cover () of the sub-plate is removed, you can see the plug-in type terminal block () mounted inside the sub-plate. The following markings are on the terminal block. Connect with corresponding power side. Solenoid side Solenoid side Terminal block marking + + pplicable terminal: S000:.-,.-S,.Y-N,.Y-S S000:.-.M,.Y-L,.Y-M S000:.-,.-M S6000:.-.M,.Y-L,.-M There is no polarity. Tightening torque for terminal: 0.6 N m Non plug-in type (With terminal) Remove cover (), over terminal block () attached to the inside of body. Connect with corresponding power side. For a type with indicator light and surge voltage suppressor, pull out the light and surge voltage suppressor substrate () in a straight direction and then connect them. side () side side () () () side () side side pplicable terminal: S000:.-,.-S,.Y-N,.Y-S S000/000/6000:.-.M,.Y-L,.Y-M There is no polarity. Tightening torque for terminal: 0.6 N m VP S S VS N -8-

156 Series S000/000/000/000/000/ lot of carbon powder and oil waste from air sources (mostly from compressor) entering into the valve sometimes can lead to increased sliding resistance at the switching spool and cause valve malfunction. In the worst case, spool can adhere to the valve. Therefore, supply air should be kept clean. lso, if it is left for a long time exposed to an inferior quality of air under SUP pressure applied, carbon powders and oil wastes in the compressed air will be accumulated in the clearance of the spool and sleeve and can cause the spool to adhere to the valve. The remedy for this case is to check the compressor lubrication oil and find out the least oxidizing compressor lubrication oil. Meanwhile, a high filtration Mist Separator (Series M) installed on the back of regular filter (Series F) can prevent foreign particles from entering into the valve. esides, as lubricant for compressors, Faircoal -80 (Nippon Mitsubishi Oil Corp.), Dafney CS, CS9 (Idemitsu Kosan Co., Ltd), etc. are commercially available on the market.. When the foreign matters from air source adhere to the spool and sleeve, disassemble the adapter plate section and end plate section (return spring insert section). Then, take out the spool and sleeve from a valve and clean them with trichlene or freon solutions. When cleaning, prevent O-rings from touching cleaning solutions.. When disassembling and reassembling, please ensure that all components are in proper positions. Prevent gaskets from slipping, and clamp bolts down equally. Use torques listed below when mounting pilot valve assemblies and solenoid valve bodies. Holding screw M Caution Maintenance Pilot Valve ssembly: SF-- Proper tightening torque (N m) 0. to 0.6 Solenoid Valve ody Holding screw Proper tightening torque (N m) M 0.8 to. M. to. M.8 to How to Calculate the Flow Rate For obtaining the flow rate, refer to page --0. Interface Regulator Specifications Interface regulator () pplicable solenoid valve series Regulating port Proof pressure Maximum operating pressure Set pressure range () mbient and fluid temperature Port size for connection of pressure gauge Weight (kg) Effective area at supply side (mm ) () P S at P = 0.7 MPa, P = 0. MPa P Effective area at exhaust side (mm ) () S at P = 0. MPa E E RF000 RF00 RF00 RF00 S000 S000 S000 S000 P P P P. MPa.0 MPa 0.0 to 0.8 MPa 0. to 0.8 MPa to 60 C (No freezing) M x Rc / Note ) Set within the operating pressure range of solenoid valve. Note ) Synthesized effective area with solenoid valve position single type. Note ) Operate an interface regulator only by applying pressure from the P port of the base, except when using it as a reverse pressure valve. To combine a pressure center valve and the and port pressure reduction of an interface regulator, use the RF000, 000, or 000 model. To combine a reverse pressure valve and an interface regulator, use the RF000, 000, or 000 model. The P port pressure reduction cannot be used. When combining a double check valve and an interface regulator, use a manifold or sub-plate as a basis, and stack them in the following order; the perfect spacer the interface regulator the valve. When a closed center valve is combined with the interface regulator's, port regulation, note that it cannot be used for intermediate stops of a cylinder because there is leakage from relief port on the regulator. JIS P port regulation RF00-00-P RF00-00-P RF00-00-P port regulation Flow Characteristics (P ) (Conditions: Inlet pressure 0.7 MPa. when position solenoid valve is mounted.) Outlet pressure (MPa) Outlet pressure (MPa) Outlet pressure (MPa) Inlet pressure 0.7 MPa Flow rate (l/min (NR)) Inlet pressure 0.7 MPa Flow rate (l/min (NR)) port regulation RF P Outlet pressure (MPa) RF Outlet pressure (MPa) Inlet pressure 0.7 MPa Inlet pressure 0.7 MPa RF Outlet pressure (MPa) Inlet pressure 0.7 MPa RF Outlet pressure (MPa) Flow rate (l/min (NR)) Flow rate (l/min (NR)) Flow rate (l/min (NR)) -8-6 Flow rate (l/min (NR)) Flow rate (l/min (NR))

157 Series S000/000/000/000/000/ Caution How to remove junction cover (Type 0) Turn the knob () of junction cover () on the manifold block side by hand or slotted screwdriver to the C O direction (counterclockwise) 90. While holding the knob and upper part of junction cover, pull outward to remove junction cover. When reassembling, do the opposite. Wiring The insert plug () is attached to the manifold block and lead wire is plugged in with valve side as shown in the following list. Single solenoid: XT6--S- ( Double solenoid: XT6--D- Connect with corresponding power side. Power supply Valve model C Single solenoid DC Double solenoid There is no polarity. Lead wire length is m. Lead Wire Connection Type 0 Insert Plug with Lead Wire Solenoid Red, lack Red, lack Series S000 (Insert plug with lead wire is not available for Series 000, 000, and 000.) () () () ( Solenoid rown, White How to Use Insert Plug When removing insert plug () from manifold base, push the lever area () of inset plug downward with thumb and pull it together with the lead wire () outward. () () () When placing the inset plug () into the manifold base, push the lever area of inset plug with thumb and plug it in its place in the receptacle housing () horizontally. fter plugging, pull lead wire out a little bit to ensure that insert plug is secure. () () Manifold/Plug-in Type 0T with Terminal lock Model Terminal block marking S00 S00 S 00 side side side COM COM COM COM side side pplicable terminal:.-,.-s,.y-n,.y-s Plugging COM bridge (part no. XT6-7: stations) in between each + COM on the block board will make the specifications of all the stations + COM and enables you to understand the wiring process. There is no polarity. Tightening torque for terminal: 0.6 N m Model Terminal block marking side side side COM COM COM COM S00 S00 side S 00 side pplicable terminal:.-.m,.y-l,.-m There is no polarity. S 000 has the marking + COM on the block board, but COM specification is also available. Tightening torque for terminal: 0.6 N m Model Terminal block marking S 00 S 00 S 00 S 00 Series S000 Remove junction cover of manifold, exposing terminal block attached to the manifold block. Lead wires from solenoid valve are connected with the terminals on upper side of terminal block. (On the terminal block, lead wire is connected with both and sides of solenoid valve in accordance with the corresponding markings and on the block.) Connect each lead wire of power side corresponding to respective solenoid valve on the lower terminal block. S000 has the marking + COM on the block board, but COM specification is also available. Series S000 Series S000/000 + side side side side side Connection Marking + pplicable terminal:.-.m,.y-l,.y-m There is no polarity. Tightening torque for terminal: 0.6 N m side side side side side VP S S VS N -8-7

158 Series S000/000/000/000/000/ Caution Type 0C Circular Connector Series 000/000/000/000 Lead Wire Connection Wire connection specifications Lead wire for both solenoid and sides in manifold are connected to connector terminal as COM specifications. (n) () Fig. () U side () () Station Type 0F D-sub Connector Manifold/Plug-in Series 000/000/000/000 Wire connection specifications Lead wire for both solenoid and sides in manifold are connected to connector terminal as COM specifications. (n) () Fig. () U side () () Station D side D side Internal Wiring of Manifold Multi-connector Connector terminal no. Note ) Maximum stations are 8. Note ) There is no polarity. Note ) Indication of stations are one station from D side regardless of the connector mounting side, D or U. pplicable Plug ssembly (Option) ssembly part no. VS VS VS VS VS VS VS Option Cable length. m m m 7 m 0 m m 0 m Cable Color List of Each Terminal No. Terminal no. Lead wire color Dot marking Terminal no. Lead wire color Dot marking Orange Orange lack lack Standard Component parts Plug pc. Cable clamp 068- pc. Socket 660- pcs. Cable VCTF cores x 0.7 mm made by Tyco Electronics MP K.K. 6 7 Green Green Red Red lue lue Yellow Yellow Wiring with control unit 8 9 Yes Yes Yes Yes Yes Yes station station station station station 6 station 7 station Max. 8 stations Connector terminal pplicable plug assembly (Option) Control unit Connector terminal ir release valve station station station station station 6 station 7 station Max. 8 stations Pressure switch 0 rown rown White White Pink Pink Gray Gray Unused Unused Light green Light green Yes Yes Yes Yes Yes Yes Internal Wiring of Manifold D-sub connector Connector terminal no. Note ) Maximum stations are 8. Note ) There is no polarity. Note ) Indication of stations are one station from D side regardless of the connector mounting side, D or U. pplicable Plug ssembly (Option) ssembly part no. VS000-- VS000-- VS000-- VS000-- VS000-- VS VS VS Option Cable Color List of Each Terminal No. Terminal no. Lead wire color lack rown Dot marking Red station station station station station 6 station 7 station Max. 8 stations Cable length. m m m 8 m 0 m m 0 m 0 m Orange Standard Connector terminal 6 Yellow Pink lue Purple Gray White White Yellow Orange pplicable plug assembly (Option) 7 Wiring with control unit Component parts 8 9 Connector terminal ir release valve station Pressure switch station Plug: ML standard D type connector terminals Cable: core wire, 0. mm 0 White lack lack Red Red Red Terminal no Lead wire color Yellow Pink lue Purple Gray Orange Red rown Pink Gray lack White Dot marking lack lack White lack White White Red Red White Control unit station station station 6 station 7 station Max. 8 stations -8-8

159 For details about certified products conforming to international standards, visit us at 9 Port Pilot Operated Solenoid Valve Metal Seal, ody Ported Series S000 Model position position Type of actuation Single Double Closed center Exhaust center Pressure S0 S center Note ) ased on JIS 87 (once per 0 days) for the minimum operating frequency. Note ) ccording to JIS (The value at supply pressure 0. MPa.) Note ) In the case of grommet type Note ) Note ) and Note ) are with controlled clean air. Compact yet provides a large flow capacity C:.8 dm /(s bar) Low power consumption:.8 W DC S0-D-0 S0-E-0 Plug-in S0 S0 S0 S0 Model Non plug-in S0-G-0-F S0-G-0 JIS position position Single Closed center Double S0 8.7 S0 S0 S0 Exhaust center Pressure center Port size Flow characteristics / (P /) / / (/ R/R) C C [dm /(s bar)] b Cv [dm /(s bar)] b Cv Standard Specifications Valve specifications Electricity specifications Option Specifications Fluid Maximum operating pressure position Min. operating pressure position Proof pressure mbient and fluid temperature Lubrication Pilot valve manual override Shock/Vibration resistance Enclosure Coil rated voltage llowable voltage fluctuation Coil insulation type pparent power Inrush C (Power consumption) Holding Power consumption (DC) Electrical entry Max. operating cycle (cpm) Response time (ms) or less or less 0 or less 0 or less 0 or less Weight (kg) ir/inert gas.0 MPa 0. MPa 0. MPa. MPa 0 to 60 C () Non-lube () Non-locking push type (Flush) 0/0 m/s () Dustproof (Degrees of protection 0) () 00, 00 VC, 0/60 Hz; VDC to +0% of rated voltage Class or equivalent (0 C) ().6 V (0 Hz),.0 V (60 Hz). V (. W)/0 Hz,. V (. W)/60 Hz.8 W (.0 W: With light/surge voltage suppressor) Grommet, Grommet terminal, Conduit terminal, DIN terminal Note ) Use dry air at low temperatures. Note ) Use turbine oil Class (ISO VG), if lubricated. Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Note ) ased on JIS C 090. Note ) ased on JIS C 00. Pilot valve manual override Coil rated voltage Option Foot bracket (With screw) Manifold Non-locking push type (Extended), Locking type (Tool required), Locking type (Lever) 0 to 0, 0, 0 VC (0/60 Hz), 00 VDC With light/surge voltage suppressor Note) Part No.: XT66-0, S0 (single) only Note) Grommet type is available only w/ surge voltage suppressor (which is directly connected with lead wire). ody type S0 S0 pplicable manifold base (Pilot EXH) ar manifold (Individual EXH) ar manifold (Common EXH base side) Note) S0: Manifold only. Cannot be used as a single unit. () () () VP S S VS N -8-9

160 Series S000 0 S 0 G 0 position single position double position closed center How to Order Port size 0 Rc 8 Manual override Nil: Non-locking push type (Flush) Thread type Nil N T F Option : Non-locking push type (Extended) Rc NPT NPTF G : Locking type Option F: With foot bracket Mountable only for S0. C : Locking type (Lever) position exhaust center position pressure center ody (Pilot exhaust) 0: Individual EXH 0 : Common EXH Manifold only How to Order Pilot Valve ssembly Coil rated voltage 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 to 0 VC (0/60 Hz) 0 VC, 0/60 Hz VDC 6 VDC 7 0 VC, 0/60 Hz 9 Other Option SF DZ Option Light/Surge voltage suppressor Nil None Z With light/surge voltage suppressor S With surge voltage suppressor Electrical entry Indicator light is not available for grommet type. With surge voltage suppressor is available for grommet type only. G: Grommet E: Grommet terminal Coil rated voltage 00 VC (0/60 Hz) 00 VC (0/60 Hz) 0 to 0 VC (0/60 Hz) 0 VC (0/60 Hz) VDC 6 VDC 7 0 VC (0/60 Hz) 9 Other Option Electrical entry, Light/Surge voltage suppressor G Grommet GS Grommet with surge voltage suppressor D DIN terminal DZ DIN terminal with light/surge voltage suppressor DO DIN terminal DOZ DIN terminal with light/surge voltage suppressor Y DIN terminal YZ DIN terminal with light/surge voltage suppressor YO DIN terminal YOZ DIN terminal with light/surge voltage suppressor T Conduit terminal TZ Conduit terminal with light/surge voltage suppressor E EZ Grommet terminal Grommet terminal with light/surge voltage suppressor Y: Conforming to DIN60 standard DIN connector is not attached. T: Conduit terminal D, Y: DIN terminal pplicable model For S0 For S0 Individual pilot exhaust Common pilot exhaust Manual override Nil Non-locking push type (Flush) Non-locking push type (Extended) Locking type (Tool required) C Locking type (Lever) Option -8-0

161 Port Pilot Operated Solenoid Valve Metal Seal, ody Ported Series S000 Cylinder Speed Chart ody Ported Construction Component Parts No. q w e r Replacement Parts No. Series S0-0 Conditions verage speed (mm/s) position single position double Closed center Exhaust center Pressure center Description ody Spool/Sleeve End plate Piston Description Material luminum die-casted Stainless steel Resin Resin t Return spring Stainless steel y Pilot valve assembly u Detent assembly ore size Series CJ Pressure 0. MPa Load factor 0% Stroke 60 mm Series CM Pressure 0. MPa Load factor 0% Stroke 00 mm Series M/C Pressure 0. MPa Load factor 0% Stroke 00 mm ø6 ø0 ø6 ø0 ø ø ø0 ø0 ø0 ø6 ø80 ø00 ody ported Series CJ Series CM Series M/C Tube bore x Length T060 x m T0806 x m S0-0 Speed controller Silencer S00F-06 S00F-08 N0-0 position closed center/exhaust center/pressure center Material Note Platinum silver Use as a guide for selection. Please confirm the actual conditions with SMC Sizing Program. Perpendicular, upward actuation Horizontal actuation It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. Load factor: ((Load weight x 9.8)/Theoretical force) x 00% Part no. S0 S0 S0/0/0 XT66-6 XT66-9 Refer to How to Order Pilot Valve ssembly on page XT6- VP S S VS N -8-

162 Series S000 Position Single Grommet: S0-G Grommet, Grommet terminal, Conduit terminal, DIN terminal Manual override Non-locking push type -ø. mounting hole Foot bracket (F) Part no.: XT66-0 -ø. mounting hole Solenoid valve 00 (Lead wire length) Manual override (Locking type) -ø. mounting hole Grommet terminal: S0-E/EZ Lead wire O.D. Max. ø. Light Manual override (Locking type) Conduit terminal: S0-T/TZ pplicable heavy-duty code O.D. ø6 to ø8 Pilot EXH (No S0) With light/surge voltage suppressor (EZ) With light/surge voltage suppressor (TZ) Light Manual override (Locking type) -Rc /8 DIN terminal: S0-D/DZ/Y/YZ pplicable heavy-duty cord O.D. ø6 to ø8 (Y: ø.7 to ø7) M x 0. x L Countersunk head screw Tightening torque: 0.6 N m With light/surge voltage suppressor (DZ) Light Manual override (Locking type) ( ): Y, YZ -8-

163 Port Pilot Operated Solenoid Valve Metal Seal, ody Ported Series S000 Position Double, Position Grommet, Grommet terminal, Conduit terminal, DIN terminal Grommet: S0-G, S0-G, S0-G, S0-G -ø. mounting hole Manual override Non-locking push type 00 (Lead wire length) Manual override (Locking type) ( position:.) -ø. mounting hole Pilot EXH (No S0) Grommet terminal: S0-E/EZ S0-E/EZ S0-E/EZ S0-E/EZ Lead wire O.D. Max. ø. ( position: 6.) With light/surge voltage suppressor (EZ) Light Manual override (Locking type) Conduit terminal: S0-T/TZ S0-T/TZ S0-T/TZ S0-T/TZ pplicable heavy-duty cord O.D. ø6 to ø8 88 ( position: 9.) With light/surge voltage suppressor (TZ) Light Manual override (Locking type) DIN terminal : S0-D/DZ/Y/YZ S0-D/DZ/Y/YZ S0-D/DZ/Y/YZ S0-D/DZ/Y/YZ pplicable heavy-duty cord O.D. ø6 to ø8 (Y: ø.7 to ø7) 88 ( position: 9.) With light/surge voltage suppressor (DZ) Light Manual override (Locking type) ( ): Y, YZ VP S S VS N -8-

164 Series S000 Manifold Specifications Single ase Type Compact and lightweight Compact due to manifolding on a single base for mounting in small spaces. Keeps environmental air clean from pilot exhaust Use of the VS-0 manifold can exhaust intensively the pilot exhaust gas to the base side, and can prevent environmental aggravation due to noise and oil mist. VS-0 VS-0 Part no. for mounting bolt and gasket G-S00 Specifications Manifold base type Port Specifications (P) Common Passage (R), (R) Common ar manifold, ody ported Max. stations Porting specifications: Rc (Connecting port size) ase (P) Side/Rc /8 Valve (), () Top/Rc /8 ase (R), (R) Side/Rc /8 Option lanking plate VS With gasket, screw How to Order Manifold ase VS Series S000 Manifold stations ase model Model Pilot exhaust Pilot individual EXH 0 0 stations Pilot common EXH How to Order Manifold ssembly no. <Examble> (Manifold base) ( position single) ( position double) (lanking plate) VS S0-D-0 S0-D-0 VS P, E, E port size 0 Rc /8 Instruct by specifying the valves and blanking plate to be mounted on the manifold along with the manifold base model Passage Porting specifications (P) (R), (R) (), () Common Common Top Rc 8 Rc 8 Rc 8 pplicable valve model S0--0 S0--0 S0--0 mountable Thread type Nil Rc N NPT T NPTF F G Option -8-

165 Port Pilot Operated Solenoid Valve Metal Seal, ody Ported Series S000 Type 0 Manifold Grommet: G Pilot individual exhaust: VS-0- Station -0 P = Manual override Formula for manifold weight M = 0.09n (kg) n: Station Grommet terminal: E/EZ Conduit terminal: T/TZ DIN terminal: D/DZ/Y/YZ position (6.) Double () Single (0.) L L U side -ø. mounting hole Gasket XT6- Lead wire O.D. Max. Ø Rc /8 (With light/surge voltage suppressor: 8.) (With light/surge voltage suppressor: 9.) 8 0 position Double Single 07 position (9.) Double (88) Single (.) 9 lanking plate Pilot EXH pplicable heavy-duty cord O.D. ø6 to ø D side 6-Rc /8 (With light/surge voltage suppressor: 86.) (With light/surge voltage suppressor: 96.) 8 0 position (9.) (Lead wire length) Double (88) Single (.) 0 69 pplicable heavy-duty cord O.D. ø6 to ø8 (Y: ø.7 to ø7) 6-Rc /8 (With light/surge voltage suppressor: 97. (99.)) (With light/surge voltage suppressor: 06. (08.)) Formula L = x n + L = x n + 9 ( ): Y, YZ n: Station VP S S VS N -8-

166 Series S000 6 Type 0 Manifold Grommet: G Pilot common exhaust: VS-0- Station -0 P = Manual override n-rc /8 U side D side Formula for manifold weight M = 0.079n (kg) n: Station Grommet terminal: E/EZ Conduit terminal: T/TZ DIN terminal: D/DZ/Y/YZ position (6.) Double () Single (0.) -ø. mounting hole L L Gasket Lead wire O.D. Max. ø. Pilot EXH port 9 77 position Double Single 6-Rc /8 (With light/surge voltage suppressor: 87.) (With light/surge voltage suppressor: 96.) lanking plate VS M x 6 XT-0- position (9.) Double (88) Single (.) 9 pplicable heavy-duty code O.D. ø6 to ø8 6 7 Pilot EXH port (With light/surge voltage suppressor: 9.) (With light/surge voltage suppressor: 0.) Rc / (Lead wire length) position (9.) Double (87) Single () Rc /8 Pilot EXH port pplicable heavy-duty code O.D. ø6 to ø8 (Y: ø.7 to ø7) Pilot EXH port 6-Rc /8 (With light/surge voltage suppressor: 0. (0.)) (With light/surge voltage suppressor:. (.)) Formula L = x n + L = x n + 9 ( ): Y, YZ n: Station -8-6

167 For details about certified products conforming to international standards, visit us at 7 Port Pilot Operated Solenoid Valve Metal Seal, ody Ported Series S000 Model position position Type of actuation Single Double Closed center Exhaust center Pressure center Plug-in S0 S0 S0 S0 S0 Model Non plug-in S0 S0 S0 S0 S0 Port size Rc Flow characteristics / (P /) / / (/ R/R) C C [dm /(s bar)] b Cv [dm /(s bar)] b Cv Note ) ased on JIS 87 (once per 0 days) for the minimum operating frequency. Note ) ccording to JIS (The value at supply pressure 0. MPa.) Note ) In the case of grommet type Note ) Factors of Note ) and Note ) are achieved in controlled clean air. Compact yet provides a high flow capacity /: C:. dm /(s bar) Low power consumption:.8 W DC S0-T-0 S0-E-0 JIS position position Single Closed center Double S0-E-0-F S0-G-0 Exhaust center Pressure center Standard Specifications Valve specifications Electricity specifications Option Specifications Manifold Fluid Maximum operating pressure Minimum operating pressure Proof pressure mbient and fluid temperature Lubrication Pilot valve manual override Shock/Vibration resistance Enclosure Coil rated voltage llowable voltage fluctuation Coil insulation type pparent power Inrush (Power consumption) C Holding Power consumption Electrical entry or less or less 0 or less 0 or less 0 or less ir/inert gas.0 MPa 0. MPa. MPa 0 to 60 C () Non-lube () Non-locking push type (Flush) 0/0 m/s () Dustproof (Degrees of protection 0) () 00, 00 VC, 0/60 Hz; VDC to +0% of rated voltage Class or equivalent (0 C) ().6 V (0 Hz),.0 V (60 Hz). V (. W)/0 Hz,. V (. W)/60 Hz.8 W (.0 W: With light/surge voltage suppressor) Grommet, Grommet terminal, Conduit terminal, DIN terminal Note ) Use dry air at low temperatures. Note ) Use turbine oil Class (ISO VG), if lubricated. Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Note ) ased on JIS C 090. Note ) ased on JIS C 00. Pilot type External pilot () Pilot valve manual override Non-locking push type (Extended), Locking type (Tool required) 0 to 0, 0, 0 VC (0/60 Hz) Coil rated voltage, 00 VDC Option With light/surge voltage suppressor () Foot bracket (With screw) Part no.: N00-7, S0 (single) only Note ) Operating pressure: 0 to.0 MPa. Pilot pressure: 0. to.0 MPa. Note ) No light grommet but surge voltage suppressor (direct connecting lead wire) is installed. ody type S0 S0 pplicable manifold base (Pilot EXH) ar manifold (Individual EXH) ar manifold (Common EXH base side) Note) S0: Manifold only. Cannot be used as a single unit. Max. operating cycle (cpm) () () () Response time (ms) Weight (kg) VP S S VS N -8-7

168 Series S000 8 How to Order S position single position double 0 G 0 Nil Port size N 0 Rc 8 T 0 Rc F Option Thread type Rc NPT NPTF G Option F: With foot bracket position closed center Manual override Nil: Non-locking push type (Flush) : Non-locking push type (Extended) : Locking type (Tool required) Mountable only for S0. position exhaust center position pressure center Reverse pressure: Can be used by external pilot specifications. ody (Pilot exhaust) How to Order Pilot Valve ssembly Option 0: Individual EXH 0: Common EXH Manifold only Pilot type Nil Internal pilot R External pilot Option: Individual external pilot (External pilot port: ody side) SF Coil rated voltage 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 to 0 VC (0/60 Hz) 0 VC, 0/60 Hz VDC VDC 0 VC, 0/60 Hz Other DZ Electrical entry, Light/Surge voltage suppressor G GS D DZ DO DOZ Y YZ YO YOZ T TZ E EZ Option Light/Surge voltage suppressor Nil None Z With light/surge voltage suppressor S With surge voltage suppressor Indicator light is not available for grommet type. With surge voltage suppressor is available for grommet type only. Electrical entry G: Grommet E: Grommet terminal Coil rated voltage 00 VC (0/60 Hz) 00 VC (0/60 Hz) 0 to 0 VC (0/60 Hz) 0 VC (0/60 Hz) VDC 6 VDC 7 0 VC (0/60 Hz) 9 Other Option Grommet Grommet with surge voltage suppressor DIN terminal DIN terminal with light/surge voltage suppressor DIN terminal DIN terminal with light/surge voltage suppressor DIN terminal DIN terminal with light/surge voltage suppressor DIN terminal DIN terminal with light/surge voltage suppressor Conduit terminal Conduit terminal with light/surge voltage suppressor Grommet terminal Grommet terminal with light/surge voltage suppressor Y: Conforming to DIN60 standard DIN connector is not attached. T: Conduit terminal D, Y: DIN terminal pplicable model For S0 For S0 Manual override Individual pilot exhaust Common pilot exhaust Nil Non-locking push type (Flush) Non-locking push type (Extended) Locking type (Tool required) Option -8-8

169 Port Pilot Operated Solenoid Valve Metal Seal, ody Ported Series S000 9 Cylinder Speed Chart ody Ported Construction Component Parts No. q w e r Description ody Spool/Sleeve End plate Piston Replacement Parts No. Series S0-0 Conditions Closed center Exhaust center Pressure center verag speed (mm/s) Description position single position double Material luminum die-casted Stainless steel Resin Resin t Return spring Stainless steel y Pilot valve assembly u Detent assembly ore size Series CJ Pressure 0. MPa Load factor 0% Stroke 60 mm Series CM Pressure 0. MPa Load factor 0% Stroke 00 mm Series M/C Note) Pressure 0. MPa Load factor 0% Stroke 00 mm ø6 ø0 ø6 ø0 ø ø ø0 ø0 ø0 ø6 ø80 ø00 ody ported Series CJ Series CM Series M/C Note) S0-0 Tube bore x Length Speed controller Silencer T060 x m S00F-06 T07 x m S00F-0 N0-0 position closed center/exhaust center/pressure center Material Note Platinum silver Use as a guide for selection. Please confirm the actual conditions with SMC Sizing Program. Perpendicular, upward actuation Horizontal actuation It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. Load factor: ((Load weight x 9.8)/Theoretical force) x 00% Note) The Series C has been changed to the Series C. Part no. S0 S0 S0/0/0 S S Refer to How to Order Pilot Valve ssembly on page N000-8 VP S S VS N -8-9

170 Series S000 0 Position Single Grommet: S0-G Grommet, Grommet terminal, Conduit terminal, DIN terminal Foot bracket (F) Part no.: N00-7 Manual override (Non-locking) -ø. mounting hole M: External pilot port ( Only for external pilot model. ) -ø. mounting hole Solenoid valve 00 (Lead wire length) Grommet terminal: S0-E/EZ Lead wire O.D. Max. ø. With light/surge voltage suppressor (EZ) Light Conduit terminal: S0-T/TZ pplicable heavy-duty code O.D. ø6 to ø8 With light/surge voltage suppressor (TZ) Light -ø. mounting hole -Rc /8, / -Rc /8 -ø. mounting hole -ø. mounting hole DIN terminal: S0-D/DZ/Y/YZ pplicable heavy-duty code O.D. ø6 to ø8 (Y: ø.7 to ø7) With light/surge voltage suppressor (DZ) Light -ø. mounting hole ( ): Y, YZ -8-0

171 Port Pilot Operated Solenoid Valve Metal Seal, ody Ported Series S000 Position Double, Position Grommet, Grommet terminal, Conduit terminal, DIN terminal Grommet: S0-G, S0-G, S0-G, S0-G 8 ( position: 9.) Manual override (Non-locking) -ø. mounting hole 00 (Lead wire length) (M: External pilot port Only for external pilot model.) Grommet terminal:s0-e/ez S0-E/EZ S0-E/EZ S0-E/EZ Lead wire O.D. Max. ø. With light/surge voltage suppressor (EZ) 8 ( position: 9) Light -ø. mounting hole Conduit terminal:s0-t/tz S0-T/TZ S0-T/TZ S0-T/TZ pplicable heavy-duty code O.D. ø6 to ø8 With light/surge voltage suppressor (TZ) 9 ( position: 9) Light -ø. mounting hole -ø. mounting hole -Rc /8, / -Rc /8 DIN terminal: S0-D/DZ/Y/YZ S0-D/DZ/Y/YZ S0-D/DZ/Y/YZ S0-D/DZ/Y/YZ pplicable heavy-duty code O.D. ø6 to ø8 (Y: ø.7 to ø7) With light/surge voltage suppressor (DZ) 9 ( position: 9) Light -ø. mounting hole ( ): Y, YZ VP S S VS N -8-

172 Series S000 Manifold Specifications Single ase Type Keeps environmental air clean from pilot exhaust Use of the VS-0 manifold can exhaust side, and can prevent environmental aggravation due to noise and oil mist. Specifications Manifold base type Port Specifications (P) Common Passage (R), (R) Common ar manifold, ody ported Max. stations Porting specifications: Rc ase Valve ase (P) Side: 8 (), () Top: 8, (R), (R) Side: 8 VS-0 VS-0 Part no. for mounting bolt and gasket G-S00 How to Order Manifold ssembly Option lanking plate VS With gasket, screw How to Order Manifold ase VS Series S000 Manifold Instruct by specifying the valves and blanking plate to be mounted on the manifold along with the manifold base model no. <Examble> (Manifold base) ( position single) ( position double) (lanking plate) VS S0-D-0 S0-D-0 VS stations ase model Model Pilot exhaust Pilot individual EXH 0 0 stations Pilot common EXH Thread type Nil Rc N NPT T NPTF F G Option P, E, E port size 0 Rc 8 Passage Porting specifications (P) (R), (R) (), () Common Common Top Rc 8 Rc 8 pplicable valve model S S S mountable Rc 8, -8-

173 Port Pilot Operated Solenoid Valve Metal Seal, ody Ported Series S000 Type 0 Manifold Grommet: G Pilot individual exhaust: VS-0- Station -0 n-rc /8, / L Grommet terminal: E/EZ Conduit terminal: T/TZ DIN terminal: D/DZ position (9) Double (8) Single () L L U side M x -ø mounting hole Lead wire O.D. Max. ø. Gasket 8 68 Pilot EXH (With light/surge voltage suppressor: 9.) (With light/surge voltage suppressor: 0) Rc /8 P = 08 8 position (9) Double (9) Single () lanking plate pplicable heavy-duty code O.D. ø6 to ø D side (With light/surge voltage suppressor: 96) Formula for manifold weight M = 0.08n (kg) n: Station 6-Rc /8 (With light/surge voltage suppressor: 06) position (9) Double (9) Single (.) 9 00 (Lead wire length) Rc /8 pplicable heavy-duty code O.D. ø6 to ø8 (Y: ø.7 to ø7) 6-Rc /8 (With light/surge voltage suppressor: 08. (0.)) (With light/surge voltage suppressor: 7. (9.)) Formula L = x n + 8 L = x n + 8 ( ): Y, YZ n: Station VP S S VS N -8-

174 Series S000 Type 0 Manifold Grommet: G Pilot common exhaust: VS-0- Station -0 M x n-rc /8, / U side D side Formula for manifold weight M = 0.n + 0. (kg) n: Station Grommet terminal: E/EZ Conduit terminal: T/TZ DIN terminal: D/DZ/Y/YZ position (9) Double (8) Single () L L L -ø mounting hole Gasket Lead wire O.D. Max. ø Rc / P = (With light/surge voltage suppressor: 98) (With light/surge voltage suppressor: 07.) position (9) Double (9) Single () 7 67 lanking plate pplicable heavy-duty code O.D. ø6 to ø Rc /8 (With light/surge voltage suppressor: 0.) (With light/surge voltage suppressor:.) 8 00 (Lead wire length) position (9) Double (9) Single (.) Rc /8 -M (Pilot EXH port) pplicable heavy-duty code O.D. ø6 to ø8 (Y: ø.7 to ø7) Formula L = x n + L = x n + 6-Rc /8 (With light/surge voltage suppressor: (7)) (With light/surge voltage suppressor: (6)) ( ): Y, YZ n: Station -8-

175 For details about certified products conforming to international standards, visit us at Port Pilot Operated Solenoid Valve Metal Seal, ody Ported Series S000 Model position position Type of actuation Single Double Closed center Exhaust center Pressure center Plug-in S0 S0 S0 S0 S0 Model Non plug-in S0 S0 S0 S0 S0 Compact yet provides a large flow capacity /8: C: 6.8 dm /(s bar) Low power consumption:.8 W DC JIS position position Single Closed center Port size Rc C [dm /(s bar)] Standard Specifications Option Specifications Manifold Flow characteristics / (P /) / / (/ R/R) b C [dm /(s bar)] or less or less 0 or less 0 or less 0 or less Note ) ased on JIS 87 (once per 0 days) for the minimum operating frequency. Note ) In the case of grommet type. Note ) ased on JIS (The value at supply pressure 0. MPa.) Note ) Factors of Note) and Note ) are achieved in controlled clean air. Double S0-E-0 S0-T-0 Exhaust center Pressure center S0-E-0-F S0-G-0 Valve specifications Electricity specifications Cv Fluid Maximum operating pressure Minimun operating pressure Proof pressure mbient and fluid temperature Lubrication Pilot valve manual override Shock/Vibration resistance Enclosure Coil rated voltage llowable voltage fluctuation Coil insulation type pparent power Inrush (Power consumption) C Holding Power consumption Electrical entry b Cv ir/inert gas.0 MPa 0. MPa. MPa 0 to 60 C () Non-lube () Non-locking push type (Flush) 0/0 m/s () Dustproof (Degrees of protection 0) () 00, 00 VC, 0/60 Hz; VDC to +0% of rated voltage Class or equivalent (0 C) ().6 V/0 Hz,.0 V/60 Hz. V (. W)/0 Hz,. V (. W)/60 Hz.8 W (.0 W: With light/surge voltage suppressor) Grommet, Grommet terminal, Conduit terminal, DIN terminal Note ) Use dry air at low temperatures. Note ) Use turbine oil Class (ISO VG), if lubricated. Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Note ) ased on JIS C 090. Note ) ased on JIS C 00. Pilot type External pilot () Pilot valve manual override Non-locking push type (Extended), Locking type (Tool reguired) 0 to 0, 0, 0 VC (0/60 Hz) Coil rated voltage, 00 VDC Option With light/surge voltage suppressor () Foot bracket (With screw) Part no.: S000-, S0 (single) only Note ) Operating pressure: 0 to.0 MPa Pilot pressure: 0. to.0 MPa ody type S0 S0 pplicable manifold base Stacking manifold Max. operating cycle (cpm) Response time (ms) Note ) Grommet type is available only w/ surge voltage suppressor (which is directly connected with lead wire), not w/ indicator light. Pilot EXH Individual EXH (Valve side) Common EXH (Manifold base side) () () () Weight (kg) VP S S VS N -8-

176 Series S000 6 How to Order How to Order Pilot Valve ssembly SF position single position double position closed center position exhaust center position pressure center Reverse pressure: Can be used by external pilot specifications. ody (Pilot exhaust) 0: Individual EXH 0 : Common EXH Coil rated voltage 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 to 0 VC (0/60 Hz) 0 VC, 0/60 Hz VDC 6 VDC 7 0 VC, 0/60 Hz 9 Other Option -8-6 S 0 G 0 DZ Manual override Nil: Non-locking push type (Flush) Option Electrical entry, Light/Surge voltage suppressor G Grommet GS Grommet with surge voltage suppressor D DIN terminal DZ DIN terminal with light/surge voltage suppressor DO DIN terminal DOZ DIN terminal with light/surge voltage suppressor Y DIN terminal YZ DIN terminal with light/surge voltage suppressor YO DIN terminal YOZ DIN terminal with light/surge voltage suppressor T Conduit terminal TZ Conduit terminal with light/surge voltage suppressor E Grommet terminal EZ Grommet terminal with light/surge voltage suppressor Y: Conforming to DIN60 standard DIN connector is not attached. Thread type Nil N Rc NPT T NPTF F G Option : Non-locking push type (Extended) Light/Surge voltage suppressor Nil None Z With light/surge voltage suppressor S With surge voltage suppressor Indicator light is not available for grommet type. W/ surge voltage suppressor is available for grommet type only. Electrical entry Coil rated voltage Port size 0 Rc 0 Rc 8 G: Grommet E: Grommet terminal 00 VC (0/60 Hz) 00 VC (0/60 Hz) 0 to 0 VC (0/60 Hz) Manifold only 0 VC (0/60 Hz) Pilot type VDC Nil Internal pilot 6 VDC R External pilot 7 0 VC (0/60 Hz) Option. It will be 9 Other an individual external pilot. Option External pilot port: ody side. For 0 type, common external pilot (on manifold side). Manual override pplicable model : Locking type (Tool required) side pilot operator for S 0 side pilot operator for S0 side pilot operator for S 0 side pilot operator for S 0 side pilot operator for S0 side pilot operator for S 0 Nil Non-locking push type (Flush) Non-locking push type (Extended) Locking type (Tool required) C Locking type (Lever) Option Option F: With foot bracket T: Conduit terminal D-Y: DIN terminal Mountable only for S0. Individual pilot exhaust Common pilot exhaust

177 Port Pilot Operated Solenoid Valve Metal Seal, ody Ported Series S000 7 Cylinder Speed Chart ody Ported Series S0-0 Conditions verage speed (mm/s) Use as a guide for selection. Please confirm the actual conditions with SMC Sizing Program. ore size Series CJ Pressure 0. MPa Load factor 0% Stroke 60 mm Series CM Pressure 0. MPa Load factor 0% Stroke 00 mm Series M Pressure 0. MPa Load factor 0% Stroke 00 mm Series CS Pressure 0. MPa Load factor 0% Cylinder stroke 000 mm ø6 ø0 ø6 ø0 ø ø ø0 ø0 ø0 ø6 ø80 ø00 ø ø0 ø60 It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. Load factor: ((Load weight x 9.8)/Theoretical force) x 00% ody ported Series CJ Series CM Tube bore x Length T060 x m T07 x m S0-0 Speed controller S00F-06 S00F-0 Silencer N00-0 Series M Series CS T09 x m S00F- N0-0 Perpendicular, upward actuation Horizontal actuation VP S S VS N -8-7

178 Series S000 8 Construction position position double Closed center Exhaust center Pressure center Component Parts No. q w e r Replacement Parts No. Description ody Spool/Sleeve End plate Piston Description Material luminum die-casted Stainless steel Resin Resin t Return spring Stainless steel y Pilot valve assembly u Detent assembly position closed center/exhaust center/pressure center Material Note Platinum silver lack Part no. S0 S0 S0/0/0 S S Refer to How to Order Pilot Valve ssembly on page S

179 Port Pilot Operated Solenoid Valve Metal Seal, ody Ported Series S000 9 Position Single Grommet: S0-G Grommet, Grommet terminal, Conduit terminal, DIN terminal Foot bracket (F) Part no.: S000- Manual override (Non-locking) -ø. mounting hole 00 (Lead wire length) -ø. mounting hole Grommet terminal: S0-E/EZ Lead wire O.D. Max. ø. -ø. mounting hole With light/surge voltage suppressor (EZ) Light Conduit terminal: S0-T/TZ pplicable heavy-duty cord O.D. ø6 to ø8 -ø. mounting hole Light M: External pilot port (For external pilot model) With light/surge voltage suppressor (TZ) -Rc /, /8 -Rc / -ø6 mounting hole DIN terminal: S0-D/DZ/Y/YZ pplicable heavy-duty cord O.D. ø6 to ø8 (Y: ø.7 to ø7) -ø. mounting hole Light Solenoid valve With light/surge voltage suppressor (DZ) ( ): Y, YZ VP S S VS N -8-9

180 Series S000 0 Position Double, Position Grommet, Grommet terminal, Conduit terminal, DIN terminal Grommet: S0-G, S0-G, S0-G, S0-G 9 ( position: 0) Manual override (Non-locking) -ø. mounting hole M: External pilot port (For external pilot model) 00 (Lead wire length) Grommet terminal: S0-E/EZ S0-E/EZ S0-E/EZ S0-E/EZ Lead wire O.D. Max. ø. -ø. mounting hole Conduit terminal: S0-T/TZ S0-T/TZ S0-T/TZ S0-T/TZ pplicable heavy-duty cord O.D. ø6 to ø8 -ø. mounting hole -ø. mounting hole 9 ( position: 0) With light/surge voltage suppressor (EZ) Light ( position: ) With light/surge voltage suppressor (TZ) Light -Rc /, /8 -Rc / DIN terminal: S0-D/DZ/Y/YZ S0-D/DZ/Y/YZ S0-D/DZ/Y/YZ S0-D/DZ/Y/YZ pplicable heavy-duty cord O.D. ø6 to ø8 (Y: ø.7 to ø7) -ø. mounting hole ( position: ) With light/surge voltage suppressor (DZ) Light ( ): Y, YZ -8-0

181 Series S000 Manifold Specifications Stacking Type Keeps environmental air clean from pilot exhaust Use of the VS- manifold can exhaust intensively the pilot exhaust gas to the base side, and can prevent environmental aggravation due to noise and oil mist. VS- Part no. for mounting bolt and gasket G-S00 Exploded View of Manifold Manifold block assembly VS Hexagon socket head cap screw: M x (XT-7-) Gasket Specifications Port Specifications Option Manifold base type (P) Common Passage (R), (R) Common How to Order Manifold ase Stacking type Max. stations Porting specifications: Rc ase Valve ase (P) Side: 8 (), () Top:, 8 (R), (R) Side: 8 lanking plate VS With gasket, screw SUP block disk XT66-0 EXH block disk XT66- Note) Individual SUP or EXH is possible with bottom porting of SUP or EXH. For your order, please indicate it in the manifold specification sheet. VS Series S000 Manifold For increasing the manifold bases, please prepare the manifold block assembly no stations ase model Model Pilot exhaust Pilot common EXH Type 0 stations Thread type Nil Rc N NPT T NPTF F G Option P, E, E port size 0-Rc 8 Passage Porting specifications (P) (R), (R) (), () Common Common Top Rc 8 Rc 8 Rc, Rc pplicable valve model S S0-- Note) lso S0 is possible to manifold. In this case, it uses an individual pilot exhaust. How to Order Manifold ssembly no. <Example> (Manifold base) ( position single) ( position double) (lanking plate) Type 0 Instruct by specifying the valves and blanking plate to be mounted on the manifold along with the manifold base model VS S0-D-0 S0-D-0 VS VP S S VS N -8-

182 Series S000 Type Manifold Grommet: G Pilot common exhaust: VS-- Station -0 n-rc /, /8 M x U side D side Formula for manifold weight M = 0.8n (kg) n: Station Grommet terminal: E/EZ Conduit terminal: T/TZ DIN terminal: D/DZ/Y/YZ L position (0) Double (9) Single () L L Lead wire O.D. Max. ø. Rc /8 External pilot port -ø7 mounting hole Gasket Rc /8 Pilot EXH port: PE (With light/surge voltage suppressor: 0.) (With light/surge voltage suppressor: ) 08 P = 9 position () Double () Single () lanking plate pplicable heavy-duty cord O.D. ø6 to ø8 6-Rc /8 6-Rc / Rc /8 Pilot EXH port: PE (With light/surge voltage suppressor: 09) (With light/surge voltage suppressor: 9) (Lead wire length) position (0) Double (0) Single () -Rc /8 Pilot EXH port: PE (With light/surge voltage suppressor: 8. (0.)) ( ): Y, YZ n: Station Rc /8 pplicable heavy-duty cord O.D. ø6 to ø8 (Y: ø.7 to ø7) 6-Rc /8 -Rc /8 Pilot EXH port: PE (With light/surge voltage suppressor: 9. (.)) Formula L = x n + L = x n

183 For details about certified products conforming to international standards, visit us at Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 Model position position Type of actuation Single Double Closed center Exhaust center Pressure center Double check Plug-in S00 S00 S00 S00 S00 S600 Note ) ased on JIS 87 (Once per 0 days) for the minimum operating frequency. Note ) ased on JIS (The value at supply press. 0. MPa). Note ) Values for S00-FZ-0. Note ) Factors of Note ) and Note ) are ones achieved in controlled clean air. Compact yet provides a large flow capacity /: C:.8 dm /(s bar) Low power consumption:.8 W DC Easy maintenance types of sub-plates: Plug-in and non plug-in JIS Non plug-in type Model Non plug-in S0 S0 S0 S0 S0 S60 position position Single Closed center Double Exhaust center Pressure center Double check Port size Rc Flow characteristics / (P /) / / (/ R/R) C C [dm /(s bar)] b Cv [dm /(s bar)] b Cv Standard Specifications Valve specifications Electricity specifications Fluid Maximum operating pressure position Min. operating pressure position Proof pressure mbient and fluid temperature Lubrication Pilot valve manual override Shock/Vibration resistance Enclosure Coil rated voltage llowable voltage fluctuation Coil insulation type pparent power Inrush (Power consumption) C Holding Power consumption DC Electrical entry Option Specifications or less or less 0 or less 0 or less 0 or less or less ir/inert gas.0 MPa 0. MPa 0. MPa. MPa 0 to 60 C () Non-lube () Non-locking push type (Flush) 0/0 m/s () Type G, E: Dustproof (Class 0), Type F, T, D: Splashproof (Class ) () 00, 00 VC, 0/60 Hz; VDC to +0% of rated voltage Class or equivalent (0 C) ().6 V/0 Hz,.0 V /60 Hz. V (. W)/0 Hz,. V (. W)/60 Hz.8 W (.0 W: With light/surge voltage suppressor) Conduit terminal Non plug-in type Grommet terminal, DIN terminal Note ) Use dry air at low temperatures. Note ) Use turbine oil Class (ISO VG), if lubricated. Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and deenergized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Note ) ased on JIS C 090. Note ) ased on JIS C 00. Pilot type Manual override Coil rated voltage Porting specifications Option External pilot Note) Non-locking push type (Extended), Locking type (Tool required), Locking type (Lever) 0 to 0, 0, 0 VC, 0/60 Hz, 00 VDC ottom ported With light/surge voltage suppressor Note) Operating pressure: 0 to.0 MPa Pilot pressure position: 0. to.0 MPa position: 0. to.0 MPa Compact, lightweight type sub-plate Compared with the standard type, this is the subplate having the reduced external dimensions and lighter weight. ut, use caution that Cv factor or piping port position is different from the standards. For details, refer to page -8-. Sub-plate Max. operating cycle (cpm) L (mm) Weight (kg) Standard type Compact type position single Rc / () () Response time (ms) Sonic conductance C [dm /(s bar)]..8 () Weight (kg) -8- VP S S VS N

184 Series S000 How to Order With attachment plug lead wire With terminal block ody type O: sub-plate Nil Z Option None With light/surge voltage suppressor Electrical entry F: Porting specifications Nil Option Side ported ottom ported Port size Nil 0 Rc 8 0 Rc Nil N T F Option Rc NPT NPTF G Without sub-plate conduit terminal (With terminal block) Standard type Note) grommet P0 Rc 8 (With attachment Note) plug lead wire) P0 Rc Compact type Note) Please note Cv Thread type factor and piping port location of compact subplate is different from standard. Refer to page -8- for details. 6 Plug-in position single position double position closed center position exhaust center position pressure center position double check S 00 F 0 S Non plug-in Coil rated voltage 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 to 0 VC (0/60 Hz) 0 VC, 0/60 Hz VDC 6 VDC 7 0 VC, 0/60 Hz 9 Other Option -8- G GS ody type : Non plug-in type sub-plate Nil R Option 0 Pilot type Internal pilot External pilot Option: External pilot is possible only to the one with sub-plate. Coil rated voltage 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 to 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC VDC 0 VC, 0/60 Hz Other E 0 Port size Pilot valve manual override Nil: Non-locking push type Nil Without sub-plate : Locking type (Flush) (Tool required) Rc 0 Non plug-in type, 8 Standard 0 Rc type : Non-locking push type C Note) Rc : Locking type Non plug-in type, S0 (Extended) (Lever) 8 Compact Note) Rc type S0 Note) Please note Cv factor and piping Option Option port location of compact sub-plate Nil None are different from standard. Refer to Z With light/surge voltage suppressor page -8- for S With surge voltage suppressor details. Indicator light is not available for grommet type. With surge voltage suppresor is avilable for grommet type only. Electrical entry G: Grommet E: Grommet terminal T: Conduit terminal D, Y: DIN terminal How to Order Pilot Valve ssembly SF Electrical entry, Light/Surge voltage suppressor F Plug-in Plug-in D DZ DO DOZ Y YZ Grommet Grommet with surge voltage suppressor DIN terminal DIN terminal with light/surge voltage suppressor DIN terminal DIN terminal with light/surge voltage suppressor DIN terminal DIN terminal with light/surge voltage suppressor Non plug-in DZ 0 YO YOZ T TZ E EZ DIN terminal DIN terminal with light/surge voltage suppressor Conduit terminal Conduit terminal with light/surge voltage suppressor Non plug-in Grommet terminal Grommet terminal with light/surge voltage suppressor DIN connector is not attached. Refer to page -8- for voltage conversion. Y: Conforming to DIN60 standard Manual override Non-locking Nil push type (Flush) Non-locking push type (Extended) Locking type (Tool required) C Locking type (Lever) Option

185 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 Cylinder Speed Chart System Components System Solenoid valve System Series S000 Rc 8 Series S000 Rc verage speed (mm/s) Speed controller Silencer S000-0 N0-0 (S = mm ) (S = mm ) S000-0 (S = mm ) N0-0 (S = mm ) Double Check Spacer/Specifications Can hold an intermediate cylinder position for an extended time If the double check spacer with a built-in double check valve is combined, it will enable the cylinder to stop in the intermediate stroke and maintain its position for a long time without being affected by the leakage between the spools. Use as a guide for selection. Please confirm the actual conditions with SMC Sizing Program. ore size Series CM Pressure 0. MPa Load factor 0% Stroke 00 mm Series M Pressure 0. MPa Load factor 0% Stroke 00 mm Series CS Pressure 0. MPa Load factor 0% Cylinder stroke 000 mm ø0 ø ø ø0 ø0 ø0 ø6 ø80 ø00 ø ø0 ø60 Double check spacer Tube bore x Length T060 x m T07 x m Specifications Double check spacer part no. pplicable valve model VS000-- S00-F Solenoid one side energized Leakage (cm /min) Solenoid both sides de-energized P P Non plug-in type VS000-- G ET S0- D R R R R R R 0 or less 0 or less Supply pressure: 0. MPa Caution In the case of position double check valve (S60), check the leakage from piping and fittings in between valve and cylinder by means of synthetic detergent solutions, and ensure that there is no such leakage found there. lso check the leakage from cylinder seal and piston seal. If there is any leakage, sometimes the cylinder, when valve is de-energized, can move without stopping at intermediate position. e aware that if the exhaust side is restricted excessively, the intermediate stopping accuracy will decrease and will lead to improper intermediate stops. It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. Load factor: ((Load weight x 9.8)/Theoretical force) x 00% 0 Check Valve Operating SUP side pressure P (MPa) Piston Cylinder pressure Operating range Cylinder pressure P (MPa) Perpendicular, upward actuation Horizontal actuation Check valve SUP side pressure (P) The combination of S 0, S 0 and a double check spacer can be used as prevention of falling at the stroke end but cannot hold the intermediate position of the cylinder. 0 0 VP S S VS N -8-

186 Series S000 6 Construction position single position double Closed center Exhaust center Pressure center Component Parts No. q w e r t y u i Replacement Parts position closed center/exhaust center/pressure center Description Material Note ody Sub-plate Spool/Sleeve luminum die-casted luminum die-casted Stainless steel Platinum silver Platinum silver dapter plate luminum die-casted Platinum silver End plate Resin lack Piston Resin Junction cover Resin Cover Resin Sub-plate ssembly (Standard) Part No. Plug-in S000-LP- 0 0 Non plug-in S000-LS- 0 Mounting bolt and gasket are not included. Part no. for mounting bolt and gasket G-S000 No. Description Material Part no. S S S// o Return spring Stainless steel N000-8 XT6-9-!0 Gasket NR XT6-0- XT6-0- XT6-0-! Hexagon socket head screw Steel XT6-6 XT6-6 XT6-6! Detent assembly XT6-! Pilot valve assembly Refer to How to Order Pilot Valve ssembly on page

187 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 7 Plug-in Position single/double, position closed center/exhaust center/pressure center/double check position single: S00-F- 0 0 Manual override (Non-locking) -ø mounting hole -Rc 8, (P), (), () bottom ported -Rc 8 (R), (R) bottom ported G Electrical entry position double: S00-F- 0 0 position closed center: S00-F- 0 0 position exhaust center: S00-F- 0 0 position pressure center: S00-F- 0 Manual override (Non-locking) 0 0. ( position: 8) -ø mounting hole 6. ( position: 7) With light/surge voltage suppressor With light/surge voltage suppressor -Rc 8, -Rc 8 ( ): Rc 8 position double check: S600-F- 0 0 Manual override (Non-locking) ottom ported (External pilot port) (M x 0.8) Pilot EXH port M x 0.8 -ø mounting hole With light/surge voltage suppressor ( ): Rc 8 ( ): Rc 8 VP S S VS N -8-7

188 Series S000 8 Non Plug-in position single Grommet: S0-G- 0 0 Manual override (Non-locking) -Rc 8, -ø mounting hole (P), (), () bottom ported -Rc 8 (R), (R) bottom ported ottom ported Grommet terminal: S0-E- 0 0 Lead wire O.D. Max. ø. Conduit terminal: S0-T- 0 0 pplicable heavy-duty cord O.D. ø6 to ø8 00 (Lead wire length) Light With light/surge voltage suppressor With light/surge voltage suppressor Light -Rc 8, -Rc 8 Pilot EXH port M x 0.8 (External pilot port M x 0.8) DIN terminal: S0- D Y- 0 0 pplicable heavy-duty cord O.D. ø6 to ø8 (Y: ø.7 to ø7), ( ): Rc 8 With light/surge voltage suppressor Light ( ): Y, YZ -8-8

189 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 9 Non Plug-in Position double, position closed center/exhaust center/pressure center Grommet: Double S0-G- 0 0 Closed center S0-G- 0 0, Exhaust center S0-G- 0 0, Pressure center S0-G- 0 0 Manual override (Non-locking) 0. ( position: 8) 7. -Ø mounting hole -Rc 8, (P), (), () bottom ported -Rc 8 (R), (R) bottom ported 00 (Lead wire length) ottom ported Grommet terminal: Double S0-E- 0 0 With light/surge voltage suppressor Lead wire O.D. Max. ø. Closed center S0-E- 0 0 Exhaust center S0-E- 0 0 Pressure center S0-E- 0 Light ( position: 9) Conduit terminal: Double S0-T- 0 0 pplicable heavy-duty cord O.D. ø6 to ø8 Closed center S0-T- 0 0 Exhaust center S0-T- 0 0 Pressure center S0-T ( position: 9) With light/surge voltage suppressor Light -Rc 8, -Rc 8 0 Pilot EXH port M x 0.8 ( ): Rc 8 DIN terminal: Double S0- D Y- 0 0 pplicable heavy-duty cord O.D. ø6 to ø8 (Y: ø.7 to ø7) (External pilot port M x 0.8) Closed center S0- D Y- 0 0 Exhaust center S0- D Y- 0 0 Pressure center S0- D Y ( position: 9) With light/surge voltage suppressor (DZ) Light, ( ): Y, YZ VP S S VS N -8-9

190 Series S000 0 Non Plug-in position double check Grommet: S60-G- 0 0 Manual override (Non-locking) -ø mounting hole -Rc /8, / (P), (), () bottom ported -Rc /8 (R), (R) bottom ported 00 (Lead wire length) ottom ported Grommet terminal: S60-E- 0 0 DIN terminal: S60- D Y- 0 0 Lead wire O.D. Max. ø. With light/surge voltage suppressor Light Conduit terminal: S60-T- 0 0 With light/surge voltage suppressor Light -Rc 8 -Rc 8, pplicable heavy-duty code O.D. ø6 to ø8 (External pilot port) (M x 0.8) Pilot EXH port M x 0.8 ( ): Rc 8 With light/surge voltage suppressor (DZ) Light pplicable heavy-duty code O.D. ø6 to ø8 (Y: ø.7 to ø7) ( ): Y, YZ -8-0

191 Series S000 Manifold Specifications Plug-in Type: With ttachment Plug Lead Wire The insert plug is attached to the manifold block and lead wire is plugged into the valve side. Please connect with corresponding power side. Plug-in Type: With Terminal lock Since lead wires of solenoid valve are connected with the terminals on upper surface of terminal block, corresponding lead wires from power source can be wired at the bottom of terminal block. One-piece junction cover Master connection of power and solenoid valves. Quick wiring permits ease of installation. U side Individual junction cover Multi-connector VS Thread type Nil N Rc NPT T Series S000 NPTF Passage Porting specifications F G Manifold P E, E, Option Port size With attachment plug lead wire Side Common Common ottom P, E, E, 0 Rc Rc 8 Side Common Individual ottom 0 Rc 0 stations M Mixed 6 Side Individual Common ottom stations 7 For bottom ported, 8 Side Individual Individual Rc /8 is only With attachment plug lead wire ottom Option available. VS Series S000 Manifold With terminal block Junction cover Separate junction Nil cover One-piece junction cover VS Series S000 Manifold 0T 0 stations stations 0C D With multi-connector Connector mounting direction D U Junction cover One-piece junction cover VS D U Junction cover One-piece junction cover D side mounting U side mounting Plug-in Type: With D-sub Connector (Wiring specifications: Refer to page -8-8.) Wide range of interchangeability (D-sub connector (P) conforming to MIL standard) Quick wiring permits easier installation. U side D-sub connector 0F U Series S000 With D-sub connector Manifold Connector mounting direction VS Series S000 Manifold Non plug-in type D side mounting U side mounting 0 0 stations stations 08 0 Passage Porting specifications P E, E, Side Common Common ottom Side Common Individual ottom Individual 6 Side Common ottom 7 8 Side Individual Individual ottom Option 0 0 Thread type Nil N Rc NPT T NPTF F G Option Port size P, E, E, 0 Rc Rc 8 0 Rc M Mixed Thread type Nil N Rc NPT T NPTF Passage Porting specifications F G P E, E, Option Port size Side Common Common ottom P, E, E, 0 Rc Rc 8 Side Common Individual ottom 0 Rc 0 stations M Mixed Individual 6 Side Common ottom 08 8 stations 7 For bottom Max. 8 stations 8 Side ported, Rc /8 is Individual Individual ottom Option only available. 0 stations 08 8 stations Max. 8 stations 06 0 Non Plug-in Type: Grommet, Grommet Terminal, Conduit Terminal, DIN Terminal Wiring for every valve Plug assembly Refer to page D side Plug assembly Refer to page D side Conduit port 0 0 Thread type Nil Rc N NPT T NPTF Passage Porting specifications F G P E, E, Option Port size Side Common Common ottom P, E, E, 0 Rc Side Common Individual ottom Rc 8 0 Rc Individual M Mixed 6 Side Common ottom 7 8 Side For bottom Individual Individual ported, Rc /8 is ottom Option only available. Passage Porting specifications P E, E, Side Common Common ottom Side Common Individual ottom 6 Side Individual Common ottom 7 8 Side Individual Individual ottom Option Thread type Nil N Rc NPT T NPTF F G Option Port size P, E, E, 0 Rc Rc 8 0 Rc M Mixed For bottom ported, Rc /8 is only available. Note) The individual specification of the P port at the composition symbol to 8 or the E, E, ports should be taken as individual port using a block plate. Therefore, if an individual port is using a single SUP spacer of option or a single EXH spacer, the composition symbol mark is. For bottom ported, Rc /8 is only available. -8- VP S S VS N

192 Series S000 How to Order Manifold ssembly Please indicate manifold base type, corresponding valve, and option parts. <Example> with terminal block (6 stations, one-piece style junction cover) (Manifold base) VS-0T-06-0 ( position single) S00-FZ ( position double) S00-FZ (lanking plate) VS000-0 Non plug-in type (6 stations) (Manifold base) VS ( position single) S0-D ( position exhaust center) S0-D (Individual EXH spacer) VS000-R-0- Manifold Specifications ase model VS-0 Non plug-in type VS-0 Wiring With attachment plug lead wire With terminal block With multi-connector With D-sub connector Grommet Grommet terminal Conduit terminal DIN terminal Porting specifications, port Side/ottom Port size Rc P, E, E, to 8, stations With circular connector, with D-sub connector: 8 stations at the maximum. pplicable valve model S00-F S0-G S0-E S0-T S0-D Flow Characteristics at the Number of Manifold (Operated individually) Model VS Passage/ / (P /) / / (/ R/R) Port size Rc C [dm /(s bar)]. b Cv C [dm /(s bar)] b Cv Station Station Station Manifold Option Parts ssembly Individual SUP spacer n individual SUP spacer set on manifold block can form SUP port for every valve. ody type Non plug-in type Rc 8 VS000-P-0- VS000-P-0- Rc VS000-P-0- VS000-P-0- Part no. Individual EXH spacer n individual EXH spacer set on manifold block can form EXH port for every valve. (Common EXH type) ody type Non plug-in type Rc 8 VS000-R-0- VS000-R-0- Rc VS000-R-0- VS000-R-0- Part no. SUP block disk When supplying manifold with more than two different pressures, high and low, insert a block disk in between stations subjected to different pressures. ody type Part no. Non plug-in type XT6- EXH block disk When valve exhaust affects the other stations on the circuit or when the reverse pressure valve is used to standard manifold valve, insert EXH block disk in between stations to separate valve exhaust. ody type Part no. Non plug-in type XT6- Throttle valve spacer Needle valve set on the manifold block can control cylinder speed by throttling exhaust. Interface regulator (P port regulation) Interface regulator set on manifold block can regulate the pressure to each valve. Refer to Flow Characteristics on page ody type Non plug-in type P port regulation RF P- RF P- ody type Non plug-in type Part no. VS000-0 ir shutoff valve spacer When stopping supply air and releasing residual pressure after completion of work, actuators may move from original position. ir shut off valve spacer makes it possible to stop actuators in original position for extended periods. ody type Part no. VS000-- Non plug-in type VS000-- Not mountable for standard type sub-plate. ir release valve spacer The concurrent use of air release valve spacer with S0 can release air. ody type Non plug-in type Part no. L VS000-- R L VS000-- R Note) L: U side mount R: D side mount Double check spacer If the double check spacer with a built-in double check valve is combined, it will enable the cylinder to stop in the intermediate stroke and maintain its position for a long time without being affected by the leakage between the spools. ody type Non plug-in type Part no. VS VS ody type Part no. VS000-- Non plug-in type VS000-- lanking plate It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. ccessory One pair of gasket and mounting thread is attached to every option parts assembly. Manifold Option With control unit /Non plug-in type Filter, regulation valve, pressure switch and air release valve are all combined to form one unit. Piping processes are eliminated. For details, refer to page With serial interface unit for serial transmission Solenoid valve wiring process reduced considerably. Disperse installation possible. Manifold solenoid valve: 8 stations max. positions ( solenoids). Maintenance and inspection are easy. For details, refer to Serial Transmission catalog separately. -8-

193 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 Manifold, Non plug-in type (Insert plug with lead wire): VS-0- Station - Port size U side n-rc /8 (), () port ottom ported: VS-0- Station - Port size L ottom ported: VS-0- Station - Port size Formula for manifold weight M = 0.0n (kg) n: Station n-rc 8 (), () port Formula for manifold weight M = 0.7n (kg) L L Rc /8 Pilot EXH port -G / Electrical entry Non plug-in type: VS-0- Station - Port size -Rc 8 Pilot EXH port n: Formula L = 8 x n + 7 L = 8 x n + 6 D side (), () port With light/surge voltage suppressor (P), (R), (R) port U side D side 00 mm (Lead wire length) 6-Rc / (P), (R), (R) port n-rc 8, (), () port 6-Rc n-rc 8, VP S S VS N -8-

194 Series S000 Manifold : Individual/One-piece junction cover with terminal block (Individual junction covers): VS-0T- Station - Port size U side n-rc 8 (), () port Formula for manifold weight M = 0.n + 0. (kg) n: Station ottom ported: VS-0T- Station - Port size L ottom ported: VS-0T- Station - Port size n-rc 8 (), () port Formula for manifold weight M = 0.6n + 0. (kg) n: Station L L Rc 8 Pilot EXH port -G Electrical entry n-rc 8 Pilot EXH port -G Electrical entry Formula L = 8 x n + 7 L = 8 x n + 6 D side n-rc 8, (), () port With light/surge voltage suppressor 6-Rc (P), (R), (R) port with terminal block (One-piece junction covers): VS-0T- Station - Port size U side With light/surge voltage suppressor (P), (R), (R) port D side n-rc 8, (), () port 6-Rc -8-

195 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 Manifold Plug-in with multi-connector/with D-sub connector Plug-in with multi-connector: VS-0CD- Station - Port size, VS-0CU- Station - Port size U side ottom ported: VS-0 CD CU - Station - Port size with D-sub connector: VS-0FD- Station - Port size, VS-0FU- Station - Port size L Formula for manifold weight M = 0.n + 0. (kg) n: Station Wiring specifications: Refer to page ottom ported: VS-0 FD FU - Station - Port size Formula for manifold weight M = 0.78n (kg) Wiring specifications: Refer to page L L n-rc 8 (), () port n-rc 8 (), () port n: Formula L = 8 x n + 7 L = 8 x n + 6 Plug assembly: VS (Option: Refer to page -8-8.) n-rc 8 Pilot EXH port Plug assembly: VS000-- (Option: Refer to page -8-8.) -Rc 8 Pilot EXH port D side n-rc 8, (), () port With light/surge voltage suppressor 6-Rc (P), (R), (R) port U side D side n-rc 8, (), () port With light/surge voltage suppressor 6-Rc (P), (R), (R) port VP S S VS N -8-

196 Series S000 6 Manifold Option Parts Individual SUP spacer: VS000-P () VS000-P (Non plug-in type), Non plug-in type Interface regulator: RF P- () RF P- (Non plug-in type) Individual SUP spacer Interface regulator SUP port Individual EXH spacer: VS000-R () VS000-R (Non plug-in type) Individual EXH port SUP block disk: XT6- EXH block disk: XT6- lock disk Throttle valve spacer: VS () VS (Non plug-in type) Throttle valve spacer EXH port ir shutoff valve spacer: VS000-- () VS000-- (Non plug-in type) Release valve spacer: VS000-- R L () VS000-- R L (Non plug-in type) Valve S0 (Single) Release valve spacer ir shutoff valve spacer Note) VS000-- R. D-side mounting. Double check spacer: VS000-- () VS000-- (Non plug-in type) SUP port Double check spacer -8-6

197 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 7 Manifold with Control Unit Control unit (Filter, Regulator, Pressure switch, ir release valve) are all standardized to the one unit, and can be mounted on the manifold base without any attachments. Piping processes are eliminated. Non plug-in type When using an air filter with auto-drain or manual drain, mount the filter vertically. 0 0T 0C 0F 0 Caution How to Order Manifold Specifications Wiring Manifold pplicable valve model Porting specifications Rc : VS-0 Plug-in with attachment plug lead wire With terminal block With multi-connector With D-sub connector S00-F (), () port (P), (R), (R) port With multi-connector, or D-sub connector: 8 stations max. Control Unit Specifications ir filter (With auto-drain/with manual drain) Filtration degree µm Regulator Set pressure (Outlet pressure) 0.0 to 0.8 MPa Pressure switch () Set pressure range: OFF 0. to 0.6 MPa Differential 0.08 MPa or less Contact a Indicator light LED (RED) Max. switch capacity V C, W DC VC/DC or less: 0 m Max. operating current 00 VC/DC: 0 m ir release valve (Single only) Operating pressure range 0. to.0 MPa VS P Series S000 Manifold ase type/electrical entry with attachment plug lead wire with terminal block with multi-connector with D-sub connector Non plug-in type Connector mounting direction With connector pplicable base Nil None 0, 0T, 0 0 stations D D side mounting 0C, 0F U U side mounting stations Junction cover ase type 0, 0T, 0: to stations Nil Stacking type 0C, 0F: to 8 stations Integrated type Note) Stacking type: Porting ase type 0, 0T Passage specifications Integrated type: P E, E, ase type 0T, 0C, 0F Side Common Common ottom Side Common Individual ottom Side 6 Individual Common ottom 7 Side 8 Individual Individual Option ottom The individual specification of the P port in the composition symbol marks to 8 or E, E ports should be taken as individual port using a block plate. Therefore, if an individual port is taken using a single SUP spacer of option or a single EXH spacer, the composition symbol mark is. Port size 0 0 M Nil N T F Option P, E, E Rc Non plug-in type: VS-0 Grommet Grommet terminal Conduit terminal DIN terminal S0-G, S0-E S0-T, S0-D Common SUP, Common EXH Side: Rc /8, /, ottom: Rc /8 (Option) Side: Rc /, /8, ottom: Rc /8 (Option) to stations Control Unit/Option ir release valve spacer Pressure switch () <> VS000--R (D side mounting) VS000--L (U side mounting) <Non plug-in type> VS000--R (D side mounting) VS000--L (U side mounting) IS000P-- With control unit/filter regulator MP- lanking Pressure switch MP- plate Release valve XT6-8 Filter element - Note ) Voltage: VDC to 00 VC Inner voltage drop: V Note ) Refer to manifold option parts on page -8-. Note ) The non plug-in type cannot be mounted afterwards. Note) The manifold of plug-in type with attachment plug lead wire is applied to individual type only. Non plug-in type has no junction ir release valve coil rating Nil None (F, G type only) 00 VC, 0/60 Hz VDC 9 Other Control unit type Control equipment Nil P M MP F G C E ir filter with auto-drain ir filter with manual drain Regulator ir release valve Pressure switch lanking plate (ir release valve) lanking plate (Filter, Regulator) lanking plate (Pressure switch) Number of manifold blocks required for mounting (stations) Thread type Rc NPT NPTF G, Rc 8 Rc Mixed () Please indicate manifold base type, corresponding valve, and option parts. <Example> with terminal block (Manifold base) VS-0T-09-0-MP ( position single) S00-FZ ( position double) S00-FZ stations are needed to mount control unit. Non plug-in type (Manifold base) VS M ( position single) S0-D stations are needed to mount control unit. VP S S VS N -8-7

198 Series S000 8 Manifold with Control Unit, Non plug-in type : VS-0T- Station - Port size - Control unit Voltage for release valve Example for manifold Individual EXH spacer U side n-rc 8, Double check spacer Individual SUP spacer Pressure switch electrical entry -Rc 8 Pilot EXH port -G Electrical entry Pilot EXH port Pressure switch ir release valve D side Po port Po port With light/surge voltage suppressor (P), (R), (R) port Pressure switch ir release valve D side U side 6-Rc L L L Control unit Non plug-in type: VS-0- Station - Port size - Control unit Voltage for release valve n-rc 8,, port (P), (R), (R) port Example for manifold Outlet for check Control unit Pressure switch n: Formula L = 8 x n + 7 L = 8 x n + 6 L (MP) L = 8 x n + 9 L (P) L = 8 x n +. ir release valve ir filter regulator ir release valve Outlet for check ir filter regulator Control unit Individual EXH spacer Double check spacer Individual SUP spacer Pressure switch -8-8

199 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 9 Dripproof Manifold (Equivalent to IP6) Manifold Specifications Manifold VS-0WT U D VS-0W Wiring pplicable value model Common terminal box ttachment plug lead wire S00-F-X Common SUP, Common EXH Porting specifications (), () port Side: Rc /8, /, ottom: Rc /8 (Option) Rc (P), (R), (R) port Side: Rc / to 0 stations to stations How to order manifold 0WTU 0WTD 0W VS Plug-in dripproof manifold (Equivalent to IP6) Common terminal box (U side mounting) Common terminal box (D side mounting) ttachment plug lead wire How to order valves 6 S Nil R Option position single position double position closed center position exhaust center position pressure center position double check 00 Pilot type Internal pilot External pilot How to Order 0WTU stations F stations Port size P, R, R, 0 0 Rc Rc 8 Rc M Mixed For bottom ported, / port is available only with Rc 8. Passage P, R, R, Side Common ottom Option X Coil rated voltage 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 to 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC 6 VDC 7 0 VC, 0/60 Hz 9 Other Option Nil Z Dripproof Pilot valve manual override Nil Non-locking push type (Flush) Non-locking push type (Extended) Locking type (Tool required) C Locking type (Lever) Option Option None With light/surge voltage suppressor Porting specifications VP S S VS N -8-9

200 Series S000 0 Dripproof Manifold U With common terminal box: VS-0WT - Station - Port size D -Rc 8 Pilot EXH port Push type manual override Indicator light 8 ( position) 0. (Double) 0 (Single) 6-Rc (P), (R), (R) port -Rc 8 External pilot port x Printed D side U side ottom ported: VS-0WTD- Station -0 Terminal mounting stations are not included. Indicates Solenoid valve mounting stations. -G Electrical entry 6-Rc (P), (R), (R) port ottom ported: VS-0W- Station -0 L L L 70 8 n-rc 8 -Rc 8 External pilot port L 6 -G Electrical entry L L -Rc 8 Pilot EXH port Insert plug with lead wire Lead wire length L = ( position) 0. (Double) 0 (Single) D side With attachment plug lead wire: VS-0W- Station - Port size n-rc n-rc 8, (), () port Push type manual override P = n-rc 8, (), () port Indicator light U side n: Formula L = x n + 9 L = x n + 06 n: Formula L = n + L = n

201 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 Manifold ase Construction, Non plug-in type End plate (D side) Replacement Parts No. q w e r t y u Description Connection fitting Connection fitting Gasket Gasket O-ring O-ring O-ring dapter plate dapter plate assembly Material Steel plate Steel plate NR NR NR NR NR Resin i End plate (U side) dapter plate Resin For 0 For 0T For 0T For 0C For 0F For 0SU Replacement Parts: Sub ssembly Part no. XT6-- XT6- XT6-7 XT6-6 8 x x. 0. x 7. x. 8 x x. XT6-6 XT6-8- (Terminal section with adapter plate) XT6-8- V XT6-6 No. Description Material Part no. o For 0 For 0T Junction cover For 0T assembly For 0C For 0F For 0SU XT6-7 XT6-8- XT V Z78-0- For 0 XT- Rubber plug NR 0T! For 0SU XT6- Plug For 0 W EXPS For increasing the manifold bases, please order the manifold block assembly number of the principle number assembly!0. For plug-in type: The manifold base with terminal stand (integrated with a junction cover) is required with the o junction cover assembly. Note) Manifold ase/construction: with terminal block. No. Description ssembly part no. Component parts pplicable manifold base Note) Manifold block!0, Metal joint q, w. O-ring t, y, u Junction XT6-0- cover, dapter plate, Pin housing, Guide, Insert plug lead wire With attachment plug lead wire!0 Manifold block Note) Manifold block!0, Metal joint q, w, O-ring t, y, u Terminal i, assembly XT6-0- Junction cover o, daptor plate, Pin housing, Guide With terminal block Note) XT6-0- Manifold block!0, Metal joint q, w, O-ring t, y, u Non plug-in type XT6- End plate (U)!, Metal joint q, w, Gasket e, Guard! With attachment plug lead wire End plate (U side)! assembly XT6--0 End plate (U)!, Metal joint q, w, Gasket e, Guard! With terminal block XT6--0 End plate (U)!, Metal joint q, w, Gasket e, Guard! Non plug-in type XT6- End plate (D)!, Metal joint q, w, Gasket r, Guard!, Steel ball With attachment plug lead wire! End plate (D side) assembly XT6--0 End plate (D)!, Metal joint q, w, Gasket r, Guard!, Steel ball With terminal block XT6--0 End plate (D)!, Metal joint q, w, Gasket r, Guard!, Steel ball Non plug-in type Note), ports: /8, / VP S S VS N -8-

202 Series S000 Light Compact Type Sub-plate/C:.8 dm /(s bar) C:. dm /(s bar) L dimension C:.8 dm /(s bar) L dimension Sub-plate Type Compact type Standard type L dimension (mm). Weight (kg) Compact type Standard type Sub-plate Compact: Plug-in, Grommet (With attachment plug lead wire) S00-F-() P0 P0 0 Sub-plate assembly part no.: S000-CP-() (0: Rc 8, 0: Rc ) 00 0 (Center) ( ): Port size P0 S0--() ( ): Port size S0 Pilot EXH port M x 0.8 Sub-plate Compact: Non plug-in S0 S0 (Center) ottom ported Port Size Port size P0 P0 0 Sub-plate assembly part no.: S000-CS-() (0: Rc 8, 0: Rc ) Pilot EXH port M x 0.8 Lead wire -ø. mounting hole G (PF) / Electrical entry -bottom ported size (Refer to the below right.) -bottom ported size (Refer to the below right.) -ø. mounting hole -bottom ported size (Refer to the below right.) Precautions Please pay attention to piping port location of sub-plate. P0/0 0 S0-- S0/0: Compact type S0-- 0: Standard type -bottom ported size (Refer to the below right.) 0 ottom ported Port P,, Rc 8 Rc ottom Ported Size Port size P0 Port P,, Rc P0 Rc, Port Size Port size S0 S0 Port ottom Ported Size Port size S0 S0 Port 8 8 P,, Rc 8 Rc P,, Rc 8 Rc 8, Electrical Connection E, E Rc 8 Rc 8 E, E M Rc 8 E, E Rc 8 Rc 8 E, E M Rc 8 Compact type, plug-in type grommet subplate (With attachment plug lead wire) The attachment plug lead wire is attached to the manifold block and lead wire is plugged in with valve side as shown in the following list. Please connect with corresponding power side. Solenoid side side Lead wire color Red lack rown White There is no polarity. -8-

203 For details about certified products conforming to international standards, visit us at Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 Model position position Type of actuation Single Double Closed center Exhaust center Pressure center Double check Compact yet provides a large flow capacity /8: C:.8 dm /(s bar) Low power consumption:.8 W DC Easy maintenance types of sub-plates: Plug-in and non plug-in Non plug-in type JIS position Single Plug-in S00 S00 S00 S00 S00 S600 Model Non plug-in S0 S0 S0 S0 S0 S60 Port size Rc Flow characteristics / (P /) / / (/ R/R) C C [dm /(s bar)] b Cv [dm /(s bar)] b Cv Standard Specifications Option 0 or less or less 0 or less 0 or less 0 or less 0 or less Note ) ased on JIS 87 (once per 0 days) for the minimum operating frequency. Note ) ased on JIS (the value at supply press. 0. MPa). Note ) The figures in the above list are for without sub-plate. In the case of with plug-in sub-plate and with non plug-in sub-plate, add 0.0 kg and 0.7 kg respectively. Note ) Note ) and Note ) are with controlled clean air. Double position Closed center Exhaust center Pressure center Double check Valve specifications Electricity specifications Fluid Maximum operating pressure Minimum operating pressure Proof pressure mbient and fluid temperature Lubrication Pilot valve manual override Shock/Vibration resistance Enclosure Coil rated voltage llowable voltage fluctuation Coil insulation type pparent power (Power consumption) C Power consumption DC Electrical entry Inrush Holding ir/inert gas.0 MPa 0. MPa. MPa 0 to 60 C () Non-lube () Non-locking push type (Flush) 0/0 m/s () Type E: Dustproof (Level 0), Type F: Dripproof (Level ), Type D: Splashproof (Level ) () 00, 00 VC, 0/60 Hz; VDC to +0% of rated voltage Class or equivalent (0 C) ().6 V/0 Hz,.0 V/60 Hz. V (. W)/0 Hz,. V (. W)/60 Hz.8 W (.0 W: With light/surge voltage suppressor) Non plug-in type Conduit terminal DIN terminal, Grommet terminal Note ) Use dry air at low temperatures. Note ) Use turbine oil Class (ISO VG), if lubricated. Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Note ) ased on JIS C 090. Note ) ased on JIS C 00. Pilot type Manual override Main valve Pilot valve Coil rated voltage Porting specifications Option Note) Operating pressure: 0 to.0 MPa Pilot pressure: 0. to.0 MPa Max. operating cycle (cpm) External pilot Note) Direct manual override type Non-locking push type (Extended), Locking type (Tool required), Locking type (Lever) 0 to 0, 0, 0 VC (0/60 Hz), 00 VDC ottom ported With light/surge voltage suppressor () () Response time (ms) () Weight (kg) VP S S VS N -8-

204 Series S000 ody type O: sub-plate How to Order Electrical entry F: conduit terminal Porting specifications Nil Side ported ottom ported Option Plug-in S 0 0 F 0 Port size Nil Without sub-plate 0 Rc 0 Rc 8 For bottom ported, Rc is only available. Thread type Nil N T F Option Rc NPT NPTF G Non plug-in position single position double position closed center position exhaust center S 6 position pressure center position double check Reverse pressure: Can be used by external pilot specifications. ody type : Non plug-in type sub-plate ody Option 0 Standard Direct manual override Option Pilot type Nil R Option D Coil rated voltage Option 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 to 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC VDC 0 VC, 0/60 Hz Other Internal pilot External pilot Option Nil Z Electrical entry 0 None With light/surge voltage suppressor E: Grommet terminal D: DIN terminal SF Coil rated voltage F 0 00 VC, 0/60 Hz Nil 00 VC, 0/60 Hz 0 to 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC 6 VDC C Option Option Refer to page -8- for voltage conversion. 7 0 VC, 0/60 Hz 9 Other Pilot valve Manual override Nil: Non-locking push type (Flush) : Non-locking push type (Extended) : Locking type (Tool required) C : Locking type (Lever) Option How to Order Pilot Valve ssembly Manual override Rated voltage Manual override Non-locking push type (Flush) Non-locking push type (Extended) Locking type (Tool required) Locking type (Lever) -8-

205 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 Cylinder Speed Chart System Components System System Solenoid valve Series S000 Rc Series S000 Rc 8 Speed controller S000-0 (S = mm ) S0-0 (S = 7 mm ) Double Check Spacer/Specifications Specifications Can hold an intermediate cylinder position for an extended time If the double check spacer with a built-in double check valve is combined, it will enable the cylinder to stop in the intermediate stroke and maintain its position for a long time without being affected by the leakage between the spools. Double check spacer verage speed (mm/s) Use as a guide for selection. Please confirm the actual conditions with SMC Sizing Program. ore size Series M Pressure 0. MPa Load factor 0% Stroke 00 mm Series CS Pressure 0. MPa Load factor 0% Cylinder stroke 000 mm ø0 ø0 ø6 ø80 ø00 ø ø0 ø60 ø80 ø00 Non plug-in type Silencer SGP (Steel pipe) Port size x Length N00-0 (S = mm ) 6 x m N00-0 (S = 60 mm ) 0 x m Double check spacer part no. pplicable valve model Leakage (cm /min) VS000-- S00-F Solenoid one side energized Solenoid P both sides de-energized Supply pressure: 0. MPa Non plug-in type VS000-- S0-D S0-E Caution In the case of position double check valve (S60), check the leakage from piping and fittings in between valve and cylinder by means of synthetic detergent solutions, and ensure that there is no such leakage found there. lso check the leakage from cylinder seal and piston seal. If there is any leakage, sometimes the cylinder, when valve is de-energized, can move without stopping at intermediate position. e aware that if the exhaust side is restricted excessively, the intermediate stopping accuracy will decrease and will lead to improper intermediate stops. P E 0 E or less E 0 E or less E 0 E Perpendicular, upward actuation Horizontal actuation It is when the cylinder is extending that is meterout controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. Load factor: ((Load weight x 9.8)/Theoretical force) x 00% Check Valve Operation SUP side pressure P (MPa) Piston Cylinder side pressure (P) Operating range The combination of S 0, S 0 and double check spacer can be used as prevention for falling at the stroke end but cannot hold the intermediate position of the cylinder. 0 Check valve SUP side pressure (P) Cylinder side pressure P (MPa) 0 VP S S VS N -8-

206 Series S000 6 Construction position single position double Component Parts No. q w e r t y u i Description ody Sub-plate Spool/Sleeve dapter plate End plate Piston Junction cover Light cover Replacement Parts Closed center Exhaust center Pressure center position closed center/exhaust center/pressure center Material luminum die-casted luminum die-casted Stainless steel Resin Resin Resin Resin Resin Note Platinum silver Platinum silver lack lack Sub-plate Part No. 0 Plug-in S000-P- 0 0 Non plug-in S000-S- 0 Mounting bolt and gasket are not included. Part no. for mounting bolt and gasket G-S000 No. Description Material Part no. S S S// o!0 Return spring Gasket Stainless steel NR S S000-0 S000-0 S S000-0! Hexagon socket head screw Steel M x M x M x! Detent assembly S000-9! Pilot valve assembly Refer to How to Order Pilot Valve ssembly on page

207 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 7 Plug-in position single, position closed center/exhaust center/pressure center/double check position single: S00-F -ø.6 mounting hole Rc /8 external pilot port (Only for external pilot) (), () port Rc 8 (PE port) Pilot valve manual override G / electrical entry position double: S00-F position closed center: S00-F position exhaust center: S00-F position pressure center: S00-F Pilot valve manual override -ø.6 mounting hole With direct manual override 86. ( position: 96.) -Rc, ( position: 7) Light window t Fz With direct manual override Light window t Fz ottom ported position double check: S600-F Pilot valve manual override -Rc -ø.6 mounting hole G / electrical entry G / electrical entry -Rc, 8 -Rc, 8 -ø.6 mounting hole Light window t Fz ( ): Rc ( ): Rc ( ): Rc With direct manual override VP S S VS N -8-7

208 Series S000 8 Non Plug-in Position single/double, position closed center/exhaust center/pressure center/double check position single: S0-E, S0-D -ø.6 mounting hole Rc /8 external pilot port (Only for external pilot) (), () port Rc 8 (PE port) Cable ø8 to ø0 Pilot valve manual override position double: S0-E, S0-D position closed center: S0-E, S0-D position exhaust center: S0-E, S0-D position pressure center: S0-E, S0-D -ø.6 mounting hole pplicable heavy-duty cord O.D. ø8 to ø0 Pilot valve manual override With direct manual override With direct manual override 6 ( position: 7) Light window t DZ, EZ -Rc, 8 Light window t DZ, EZ ( ): Rc -Rc, 8 ottom ported ( ): Rc position double check: S60-E, S60-D pplicable heavy-duty cord O.D. ø8 to ø0 Pilot valve manual override With direct manual override -ø.6 mounting hole -Rc -ø.6 mounting hole Light window at DZ, EZ -Rc, 8 ( ): Rc -8-8

209 9 Series S000 Manifold Specifications Plug-in Type: With Terminal lock Since lead wires of solenoid valve are connected with the terminals on upper surface of terminal block, corresponding lead wires from power source can be wired at the bottom of terminal block. Master connection of power and solenoid valves. Quick wiring permits easier installation. Wide range of interchangeability (MIL Spec DIN connector terminal pcs attached.) Quick wiring permits easier installation. Wiring for every valve. VS 0T Series S000 Manifold with terminal block 0 stations VS D U D U 0 0C 0 stations Plug-in Type: With Multi-connector (Wiring specifications: Refer to page -8-8.) U side D Series S000 Manifold Connector mounting with multi-connector Plug-in Type: With D-sub Connector U side Terminal block Multi-connector D-sub connector VS Series S000 Manifold with D-sub connector Non Plug-in Type: Grommet Terminal, DIN Terminal Grommet terminal DIN terminal D side Plug assembly (Option) Refer to page D side Plug assembly (Option) Refer to page VS Series S000 Manifold Non plug-in type 06 0 direction D side mounting U side mounting 0 stations 0F D side mounting U side mounting Thread type Port size P, E, E, Nil N Rc NPT 0 Rc T Rc NPTF 0 Rc 8 F G M Mixed Option Passage Porting specifications P E, E (, ) Side Common Common ottom Option stations Max. 8 stations (Wiring specifications: Refer to page -8-8.) D Connector mounting direction stations stations 0 stations 08 8 stations Max. 8 stations Thread type Port size Nil Rc P, E, E, N NPT 0 Rc T NPTF 0 Rc Rc 8 F G M Mixed Option Passage Porting specifications P E, E (, ) Side Common Common ottom Option Thread type Port size Nil Rc P, E, E, N NPT 0 Rc T NPTF 0 Rc Rc 8 F G M Mixed Option Passage Porting specifications P E, E (, ) Side Common Common ottom Option Thread type Port size Nil Rc P, E, E, N NPT 0 Rc T NPTF 0 Rc Rc 8 F G M Mixed Option Passage Porting specifications P E, E (, ) Side Common Common ottom Option -8-9 VP S S VS N

210 Series S How to Order Manifold ssembly Please indicate manifold base type, corresponding valve, and option parts. <Example> with terminal block: 6 stations (Manifold base) VS-0T-06-0 ( position single) S00-FZ ( position double) S00-FZ (lanking plate) VS000-0 <Example> Non plug-in type: 6 stations (Manifold base) VS ( position single) S0-D ( position exhaust center) S0-D (Individual EXH spacer) VS000-R-0- Manifold Option Parts ssembly Individual SUP spacer n individual SUP spacer set on manifold block can form SUP port for every valve. ody type Part no. Individual EXH spacer n individual EXH spacer set on manifold block can form EXH port for every valve. (common EXH type) ody type Part no. VS000-P-0- VS000-R-0- SUP block disk EXH block disk Non plug-in type VS000-P-0- Non plug-in type VS000-R-0- When supplying manifold with more than two different pressures, high and low, insert a block disk in between stations subjected to different pressures. ody type Part no. When valve exhaust affects the other stations on the circuit or when the reverse pressure valve is used to standard manifold valve, insert EXH block disk between stations to separate valve exhaust. ody type Part no Non plug-in type XT66- Non plug-in type XT66- Manifold Specifications ase model VS-0 Non plug-in type VS-0 Wiring With terminal block With multi-connector With D-sub connector DIN terminal Grommet terminal Flow Characteristics at the Number of Manifold (Operated individually) Model VS Throttle valve spacer Needle valve set on the manifold block can control cylinder speed by throttling exhaust. Double check spacer If the double check spacer with a built-in double check valve is combined, it will enable the cylinder to stop in the intermediate stroke and maintain its position for a long time without being affected by the leakage between the spools. Interface regulator Interface regulator set on manifold block can regulate the pressure to each valve. (Refer to page -8-6 for Flow Characteristics.) lanking plate It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. Porting specifications, port Side/ ottom Port size Rc P, E, E, () (), 8 to 0 Note ) ppropriate silencer for E, E port: N0-0 (O.D. ø7). Note ) With multi-connector, or with D-sub connector: 8 stations max. Port size: Rc /8 ody type Part no. ody type Part no. ody type P port regulation port regulation port regulation ody type Part no. Passage/ / (P /) / / (/ R/R) VS VS000-- RF00-00-P- RF RF C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv Non plug-in type VS Non plug-in type VS000-- Non plug-in type RF00-00-P- RF RF Non plug-in type VS000-0 pplicable valve model S00-F S0-D S0-E Station Station Station Manifold Option With exhaust cleaner /Non Valve exhaust noise dampening: d or more. Oil mist collection: Rate of collection 99.9% or more. Piping process reduced. For details, refer to page With control unit /Non Filter, regulation valve, pressure switch and air release valve are all combined to form one unit. Piping processes are eliminated. For details, refer to page With serial interface unit for serial transmission Solenoid valve wiring process reduced considerably. Disperse installation possible. Manifold solenoid valve: 8 stations max. positions ( solenoids). Maintenance and inspection are easy. For details, refer to Serial Transmission catalog separately.

211 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 6 Manifold, Non plug-in type (With terminal block): VS-0T- Station - Port size U side n-rc, 8 Pilot valve manual override n-rc, 8 Light window ottom ported: VS-0T- Station - Port size Formula for manifold weight M = 0.0n (kg) n: Station Non plug-in type: VS-0- Station - Port size L ottom ported: VS-0- Station - Port size Formula for manifold weight M = 0.09n + 0. (kg) L L 9 n-rc, Rc 8 (Pilot EXH port: PE) -G / Electrical entry -Rc 8 (Pilot EXH port: PE) n: Formula L = x n + 6 L = x n + 7 U side pplicable cabtire cable O.D. ø8 to ø0 D side -Rc 8 (External pilot port) Pilot valve manual override Light window D side -Rc 8 (External pilot port) 6-Rc n-rc, 8 VP S S VS N -8-6

212 Series S000 6 Manifold with multi-connector/d-sub connector with multi-connector: VS-0CD- Station - Port size, VS-0CU- Station - Port size U side Pilot valve manual override Light window L ottom ported: VS-0 - Station - Port size CD CU Formula for manifold weight M = 0.n (kg) n: Station Wiring specifications: Refer to page with D-sub connector: VS-0FD- Station - Port size, VS-0FU- Station - Port size ottom ported: FD VS-0 - Station - Port size Formula for manifold weight M = 0.n (kg) n: Station Wiring specifications: Refer to page L L 9 n-rc, 8 n-rc, FU n: Formula L = x n + 6 L = x n + 7 Plug assembly VS (Option: Refer to page -8-8.) -Rc /8 (Pilot EXH port: PE) Plug assembly VS000-- (Option: Refer to page -8-8.) D side -Rc /8 (External pilot port) U side Light window 6-Rc / Pilot valve manual override D side -Rc /8 (Pilot EXH port: PE) -Rc /8 (External pilot port) 6-Rc / n-rc, 8 n-rc, 8-8-6

213 Manifold with Exhaust Cleaner Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 6 Serves to protect working environment. Valve exhaust noise dampening: d or more. Collection rate of drainage and oil mist: 99.9% or more. Piping work is reduced. Manifold Specifications Wiring Manifold : VS-0 With terminal blocks With multi-connector With D-sub connector Non plug-in type: VS-0 DIN terminal Grommet terminal pplicable valve model S00-F S0-D, S0-E Common SUP, Common EXH Porting specifications (), () port Rc /, /8 Rc (P), (R), (R) port P: Rc /, EXH: Rc to 0 () pplicable exhaust cleaners MC60-0 (Connecting port size R ) () Note ) With multi-connector, or with D-sub connector: 8 stations max. Note ) Exhaust cleaner MC60-0 is not attached. U side Non plug-in type Caution Exhaust cleaner MC60-0 (Option) D side Exhaust cleaner MC60-0 (Option) When using an exhaust cleaner, mount it downwards. For details about exhaust cleaners, refer to est Pneumatic Vol.. VS Series S000 Manifold ase type/electrical entry 0T 0C with terminal block with multi-connector 0F 0 with D-sub connector Non plug-in type Connector mounting direction With connector pplicable base Nil D U None D side mounting U side mounting CD 0T, 0 0C, 0F 0 stations 0 0 stations ase type 0T, 0: -0 stations ase type 0C, 0F: -8 stations How to Order Please indicate manifold base type, corresponding valve, and option parts. <Example> with terminal block (6 stations) (Manifold base) VS-0T-06-0-CD ( position single) S00-FZ ( position double) S00-FZ (lanking plate) VS000-0 (Exhaust cleaner) MC60-0 Non plug-in type (6 stations) (Manifold base) VS CU ( position single) S0-E ( position double) S0-E (lanking plate) VS000-0 (Exhaust cleaner) MC60-0 Nil N T F Option Port size Exhaust cleaner mounting direction Exhaust cleaner mounting direction CD CU Thread type Rc NPT NPTF G P, 0 Rc Rc 0 Rc 8 M Mixed Passage Porting specifications P R, R (, ) Side Common Common ottom Option D side D side mounting U side U side mounting VP S S VS N -8-6

214 Series S000 6 Manifold with Exhaust Cleaner : VS-0T- Station - Port size - CD CU, Non plug-in type U side Pilot valve manual override Light n-rc, 8 Pilot valve manual override D side -Rc /8 (Pilot EXH port: PE) -G / Electrical entry Non plug-in type: VS-0- Station - Port size - CD CU -Rc /8 (Pilot EXH port: PE) Light Exhaust cleaner (Option) D side (External pilot port: X) 6-Rc / U side Exhaust cleaner (Option) D side L D side mounting -Rc /8 n-rc, 8 Pilot valve manual override -Rc /8 (External pilot port: X) 6-Rc / L L D side mounting U side D side U side U side mounting U side mounting n: Formula L = x n + 6 L = x n

215 Manifold with Control Unit Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 6 Control unit (Filter, Regulator, Pressure switch, ir release valve) are all standardized to the one unit, and can be mounted on the manifold base without any attachments. Piping processes are eliminated. U side Non plug-in type Manifold Specifications Manifold : VS-0 Non plug-in type: VS-0 With terminal block DIN terminal Wiring With multi-connector Grommet terminal With D-sub connector pplicable valve model S00-F S0-D, S0-E Common SUP, Common EXH Porting specifications (), () port Rc /, /8 Rc (P), (R), (R) port Rc / to 0 With multi-connector, or with D-sub connector: 8 stations max. Control Unit Specifications ir filter (With auto-drain/with manual drain) Filtration degree µm Regulator Set pressure (Outlet pressure) 0.0 to 0.8 MPa Pressure switch () Set pressure range: OFF 0. to 0.6 MPa Differential 0.08 MPa or less Contact a Indicator light LED (RED) Max. switch capacity V C, W DC VC/DC or less: 0 m Max. operating current 00 VC/DC: 0 m ir release valve (Single only) Operating pressure range 0. to.0 MPa VS P Series S000 Manifold ase type/electrical entry 0T with terminal block 0C with multi-connector 0F with D-sub connector 0 Non plug-in type Connector mounting direction With connector pplicable base Nil None 0T, 0 D D side mounting 0C, 0F U U side mounting 0 stations Passage 0 0 stations P E, E ase type 0T, 0: to 0 stations Common Common ase type 0C, 0F: to 8 stations Option Port size P, E, E 0 Rc 0 M D side Caution When using an air filter with auto-drain or manual drain, mount the filter vertically. Porting specifications (, ) Side ottom How to Order, Thread type Rc Rc Nil Rc 8 N Mixed NPT NPTF G T F Option Control Unit/Option ir release () valve spacer Pressure () switch lanking plate <> VS000--R (D side mounting) <Non plug-in type> VS000--R (D side mounting) Filter regulator Pressure switch Release valve IS000P-- MP- MP- VS Filter element IN--8-- Note ) Voltage: VDC to 00 VC Inner voltage drop: V Note ) Combination of valve S (single) and a release valve spacer can be used an air release valve. Note ) The non plug-in type cannot be mounted afterwards. ir release valve coil rating Nil None (F, G type only) 9 00 VC, 0/60 Hz VDC Other Control unit type Control equipment Nil P M MP F G C E ir filter with auto-drain ir filter with manual drain Regulator ir release valve Pressure switch lanking plate (ir release valve) lanking plate (Filter, Regulator) lanking plate (Pressure switch) Number of manifold blocks required for mounting (stations) Please indicate manifold base type, corresponding valve, and option parts. <Example> with terminal block In order to mount control unit, it requires stations. (Manifold base) ( position single) ( position double) <Example> VS-0T-08-0-P S00-FZ S00-FZ Non plug-in type In order to mount control unit, it requires stations. (Manifold base) ( position single) VS S0-D VP S S VS N -8-6

216 Series S Manifold with Control, Non plug-in type : VS-0T- Station - Port size -P Voltage for release valve n-rc, 8 Pilot valve manual override U side Example for manifold Individual EXH spacer (VS000-R-0-) Double check spacer (VVS000--) Individual SUP spacer (VS000-P-0-) -Rc 8 (Pilot EXH port: PE) -G Electrical entry 08 Light Pressure switch ir release valve Rc / (Po port) -Rc /8 (External pilot port: X) Non plug-in type: VS-0- Station - Port size -P Voltage for release valve Pressure switch ir release valve -Rc 8 (Pilot EXH port: PE) 08 (9: -MP) Light (9: -MP) RC / D side Pilot valve manual override U side D side n-rc, 8 Rc / (Po port) -Rc 8 (External pilot port: X) L L L L (MP) L (P) ir release valve ir filter regulator Example for manifold () () () () () () Pressure switch Outlet for check Control unit Pressure switch Formula L = x n + 6 L = x n L = x n L = x n + 8. ir release valve ir filter regulator Individual EXH spacer (VS000-R-0-) Double check spacer (VS000--) Individual SUP spacer (VS000-P-0-) Outlet for check Control unit -8-66

217 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S Manifold Option Parts Individual SUP spacer: VS000-P-0- () VS000-P-0- (Non plug-in type), Non plug-in type Double check spacer: VS000-- () VS000-- (Non plug-in type) (7: With direct manual override) Individual SUP spacer Double check spacer Individual EXH spacer: VS000-R-0- () VS000-R-0- (Non plug-in type) (7: With direct manual override) Individual EXH spacer SUP/EXH block disk: XT66- Throttle valve spacer: VS () VS (Non plug-in type) (7: With direct manual override) Throttle valve spacer lock disk mounting position Interface regulator/p port regulation: RF00-00-P- () RF00-00-P- (Non plug-in type) (68: With direct manual override) Interface regulator Interface regulator/ port regulation: RF () RF (Non plug-in type) (68: With direct manual override) Interface regulator Interface regulator/ port regulation: RF () RF (Non plug-in type) (68: With direct manual override) Interface regulator VP S S VS N -8-67

218 Series S Manifold ase Construction, Non plug-in type End plate (D side) Replacement Parts No. q w e r t y u i o! Description Connection fitting Connection fitting Gasket Gasket O-ring O-ring O-ring Terminal assembly Junction cover assembly Rubber plug Material Steel plate Steel plate NR NR NR NR NR For 0T For 0SU NR End plate (U side) Replacement Parts: Sub ssembly Part no. VS000-- VS000-- VS VS x 6.6 x.6 (End plate) 0 x 6 x (Manifold block) 6. x x.6 VS000-6 VS000-- Z78-- XT6-9 For increasing the manifold bases, please order the manifold block assembly number of the principal part assembly!0. For plug-in type: The manifold base with terminal stand (integrated with a junction cover) is required with the o junction cover assembly. Note) Manifold ase/construction: Plug-in with terminal block. No. Description ssembly part no. Component parts pplicable manifold base!0!! 0 Manifold block!0, Terminal i, Metal joint q, w, Manifold block VS Gasket e, r, O-ring y, u, Receptacle assembly assembly 0 VS Manifold block!0, Metal joint q, w, Gasket e, r, O-ring y, u Non plug-in type 0 End plate (D side) VS000-- End plate (D)!, Metal joint q, w, Gasket e assembly VS000-- End plate (D)!, Metal joint q, w, Gasket e Non plug-in type End plate (U side) assembly VS000-- VS000-- End plate (U)!, Metal joint q, w, O-ring t, y End plate (U)!, Metal joint q, w, O-ring t, y Non plug-in type -8-68

219 For details about certified products conforming to international standards, visit us at 69 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 Model position position Type of actuation Single Double Closed center Exhaust center Pressure center Double check Plug-in S00 S00 S00 S00 S00 S600 Model Non plug-in S0 S0 S0 S0 S0 S60 Note ) ased on JIS 87 (once per 0 days) for the minimum operating frequency. Note ) ased on JIS (The value at supply press. 0. MPa). Note ) The figures in the above list are for without sub-plate. In the case of with plug-in sub-plate and with non plug-in sub-plate, add 0.0 kg and 0. kg respectively. Note ) Note ) and Note ) are with controlled clean air. Compact yet provides a large flow capacity /: C: dm /(s bar) Low power consumption:.8 W DC Easy maintenance types of sub-plates: Plug-in and non plug-in JIS position Single Double position Closed center Exhaust center Pressure center Double check Port size Non plug-in type Flow characteristics () / (P /) / / (/ R/R) C C [dm /(s bar)] b Cv [dm /(s bar)] b Cv Standard Specifications Valve specifications Electricity specifications Option Specifications Pilot type Manual override Fluid Maximum operating pressure position Minimum operating pressure position Proof pressure mbient and fluid temperature Lubrication Pilot valve manual override Shock/Vibration resistance Enclosure Coil rated voltage llowable voltage fluctuation Coil insulation type pparent power (Power consumption) C Power consumption DC Electrical entry Inrush Holding ,000, or less or less 0 or less 0 or less 0 or less or less.7 ir/inert gas.0 MPa 0. MPa 0. MPa. MPa 0 to 60 C () Non-lube () Non-locking push type (Flush) 0/0 m/s () Type E: Dustproof (level 0), Type F: Dripproof (level ), Type D: Splashproof (level ) () 00, 00 VC, 0/60 Hz; VDC to +0% of rated voltage Class or equivalent (0 C) ().6 V/0 Hz,.0 V/60 Hz. V (. W)/0 Hz,. V (. W)/60 Hz.8 W (.0 W: With light/surge voltage suppressor) Non plug-in type Conduit terminal Grommet terminal, DIN terminal Note ) Use dry air at low temperatures. Note ) Use turbine oil Class (ISO VG), if lubricated. Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Note ) ased on JIS C 090. Note ) ased on JIS C 00. Main valve Pilot valve Coil rated voltage Porting specifications Option External pilot Note) Direct manual override Non-locking push type (Extended), Locking type (Tool required), Locking type (Lever) 0 to 0, 0, 0 VC, 0/60 Hz, 00 VDC ottom ported With light/surge voltage suppressor, Non-rotating DIN terminal Note) Operating pressure: 0 to.0 MPa Pilot pressure position: 0. to.0 MPa, position: 0. to.0 MPa () Max. operating cycle (cpm) () Response time (ms) ()() Weight (kg) VP S S VS N -8-69

220 Series S ody type O: sub-plate Electrical entry F: conduit terminal Plug-in S 0 0 How to Order F Porting specifications Nil Side ported ottom ported In the case of external pilot (Option), bottom piping is not available. Port size Nil Without sub-plate 0 Rc 8 0 Rc E, E: Rc 8 0 Thread type Nil N T F Option Rc NPT NPTF G Non plug-in position single position double position closed center position exhaust center S 6 position pressure center position double check Reverse pressure: Can be used by external pilot specifications. ody type : Non plug-in type sub-plate ody option 0 Standard Direct manual override Option 0 Pilot type Nil R Option E Coil rated voltage 6 7 Internal pilot External pilot Option Nil Z P Electrical entry 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 to 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC VDC 0 VC, 0/60 Hz 9 Other Option 0 None With light/surge voltage suppressor Non-rotating DIN terminal In the case of w/ Z, enter ZP. Type P is available for DIN type only. E: Grommet terminal D: DIN terminal How to Order Pilot Valve ssembly SF Coil rated voltage 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 to 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC 6 VDC 7 0 VC, 0/60 Hz 9 Other Option Refer to page -8- for voltage conversion. F 0 Pilot valve Manual override Nil: Non-locking push type (Flush) : Non-locking push type (Extended) : Locking type (Tool required) C : Locking type (Lever) Option Nil Manual override C Option Non-locking push type (Flush) Non-locking push type (Extended) Locking type (Tool required) Locking type (Lever) -8-70

221 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 7 Cylinder Speed Chart System Solenoid valve System Series S000 Rc 8 Series S000 Rc Double Check Spacer/Specifications Specifications Can hold an intermediate cylinder position for an extended time If the double check spacer with a built-in double check valve is combined, it will enable the cylinder to stop in the intermediate stroke and maintain its position for a long time without being affected by the leakage between the spools. verage speed (mm/s) System Components ore size Series C Pressure 0. MPa Note) The C series Series CS has been changed Pressure 0. MPa Load factor 0% Stroke 00 mm to the C series. Load factor 0% Cylinder stroke 000 mm ø0 ø6 ø80 ø00 ø ø0 ø60 ø80 ø00 ø0 ø00 Speed controller S0-0 (S = 7 mm ) S0-0 (S = 97 mm ) Non plug-in type Silencer N00-0 (S = 60 mm ) N00-0 (S = 90 mm ) Double check spacer SGP (Steel pipe) Port size x Length 0 x x Double check spacer part no. pplicable valve model Leakage (cm /min) VS000-- S00-F Solenoid one side energized Solenoid both sides de-energized Supply pressure: 0. MPa Caution Non plug-in type VS000-- S0-D S0-E In the case of position double check valve (S60), check the leakage from piping and fittings in between valve and cylinder by means of synthetic detergent solutions, and ensure that there is no such leakage found there. lso check the leakage from cylinder seal and piston seal. If there is any leakage, sometimes the cylinder, when valve is de-energized, can move without stopping at intermediate position. e aware that if the exhaust side is restricted excessively, the intermediate stopping accuracy will decrease and will lead to improper intermediate stops. P P E 0 E or less E 0 E or less E 0 E Use as a guide for selection. Please confirm the actual conditions with SMC Sizing Program. Perpendicular, upward actuation Horizontal actuation It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. Load factor: ((Load weight x 9.8)/Theoretical force) x 00% Check Valve Operation SUP side pressure P (MPa) Piston Cylinder side pressure (P) Operating range Check valve SUP side pressure (P) Cylinder side pressure P (MPa) The combination of S 0 0, S 0 0 and Double check spacer for prevention of falling at the stroke end but cannot hold the intermediate position of the cylinder. VP S S VS N -8-7

222 Series S000 7 Construction position single position double Closed center Component Parts No. q w e r t y u i Description ody Sub-plate Spool/Sleeve dapter plate End plate Piston Junction cover Light cover Exhaust center Pressure center Replacement Parts position closed center/exhaust center/pressure center Material luminum die-casted luminum die-casted Stainless steel luminum die-casted luminum die-casted Resin Resin Resin Note Platinum silver Platinum silver lack lack Sub-plate ssembly Part No. 0 Plug-in S000-P- 0 0 Non plug-in S000-S- 0 Mounting bolt and gasket are not included. Part no. for mounting bolt and gasket G-S000 No. Description Material Part no. S S S// o!0 Return spring Gasket Stainless steel NR ! Hexagon socket head screw Steel M x 0 M x 0 M x 0! Detent assembly 000-! Pilot valve assembly Refer to How to Order Pilot Valve ssembly on page

223 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 7 Plug-in position single/double, position closed center/exhaust center/pressure center/double check position single: S00-F -ø6. mounting hole Rc /8 external pilot port (Only for external pilot) (), () port Pilot valve manual override position double: S00-F position closed center: S00-F position exhaust center: S00-F position pressure center: S00-F Pilot valve manual override (With direct manual override) G Electrical entry With light/surge voltage suppressor G Electrical entry -Rc 8, (R, R: Rc 8 ) 87 ( position: 96.) Light window -ø6. mounting hole With light/surge voltage suppressor ottom ported 07 (FZ) -Rc 8, (R, R: Rc 8 ) (With direct manual override) 07 (FZ) -Rc 8, (R, R: Rc 8 ) -ø6. mounting hole position double check: S600-F Pilot valve manual override With light/surge voltage suppressor G Electrical entry Light window Rc 8 (PE port) -ø6. mounting hole -Rc 8, (R, R: Rc 8 ) With direct manual override VP S S VS N -8-7

224 Series S000 7 Non Plug-in position single/double, position closed center/exhaust center/pressure center/double check position single: S0-E, S0-D -ø6. mounting hole (), () port -Rc 8 (PE port) pplicable cabtire cable O.D. ø8 to ø0 Pilot valve manual override position double: S0-E, S0-D position closed center: S0-E, S0-D position exhaust center: S0-E, S0-D position pressure center: S0-E, S0-D pplicable cabtire cable O.D. ø8 to ø0 Pilot valve manual override (With direct manual override) (With direct manual override) G / G 87 ( position: 96.) DIN terminal DIN terminal -ø6. mounting hole 08 (E, EZ) 8. (D, DZ) 0. (D, DZ) 08 (E, EZ) 8. (D, DZ) 0. (D, DZ) -Rc 8, (R, R: Rc 8 ) ottom ported -ø6. mounting hole position double check: S60-E, S60-D pplicable cabtire cable O.D. ø8 to ø0 Pilot valve manual override -Rc 8, (R, R: Rc 8 ) G DIN terminal -ø6. mounting hole -Rc 8, -Rc 8, (R, R: Rc 8 ) (R, R: Rc 8 ) 77 (E, EZ) With direct manual overide 08. (D, DZ) 0. (D, DZ) -8-7

225 7 Series S000 Manifold Specifications Plug-in Type: With Terminal lock Since lead wires of solenoid valve are connected with the terminals on upper surface of terminal block, corresponding lead wires from power source can be wired at the bottom of terminal block. Terminal block Plug-in Type: With Multi-connector Master connection of power and solenoid valves. Quick wiring permits easier installation. U side Multi-connector VS 0T 06 0 Thread type Series S000 Port size Nil Rc Manifold 0 stations P, R, R, N NPT 0 Rc 8 T NPTF with terminal block Rc 0 0 stations 0 Rc F G M Mixed Option For bottom ported, Passage Porting Rc 8 is only available. specifications P R, R (, ) Side Common Common ottom Option VS Series S000 Manifold with multi-connector Connector mounting direction D U D U D side mounting U side mounting Plug-in Type With: D-sub Connector Wide range of interchangeability (MIL Spec DIN connector terminal VS pcs attached.) Quick wiring permits easier Series S000 installation. Manifold U side with D-sub connector Connector mounting D side direction D-sub connector Wiring for every valve. Plug assembly (Option) Refer to page Plug assembly (Option) Refer to page D side mounting U side mounting 0C D 0 (Wiring specifications: Refer to page -8-8.) Non Plug-in Type: Grommet Terminal, DIN Terminal Grommet terminal DIN terminal D side VS 08 8 stations Max. 8 stations Passage P R, R Side Common Common ottom (Wiring specifications: Refer to page -8-8.) 0F 0 D 0 0 stations Porting specifications (, ) Thread type Port size P, R, R, Nil N Rc NPT 0 Rc 8 T NPTF Rc 0 Rc F G M Mixed Option For bottom ported, Rc 8 is only available. Option 06 0 Thread type Port size Nil Rc 0 stations P, R, R, N NPT 0 Rc 08 8 T 8 stations NPTF Rc 0 Rc F G Max. 8 stations M Mixed Option For bottom ported, Passage Porting Rc 8 is only available. specifications P R, R (, ) Side Common Common ottom Option 0 0 Series S000 Port size Manifold 0 stations P, R, R, Non plug-in type 0 Rc stations Rc 0 Rc M Mixed Passage Porting For bottom ported, specifications Rc 8 is only available. P R, R (, ) Side Common Common ottom Option Thread type Nil Rc N NPT T NPTF F G Option -8-7 VP S S VS N

226 Series S How to Order Manifold ssembly Please indicate manifold base type, corresponding valve, and option parts. <Example> with terminal block: 6 stations (Manifold base) VS-0T-06-0 ( position single) S00-FZ ( position double) S00-FZ (lanking plate) VS000-0 Non plug-in type: 6 stations (Manifold base) VS ( position single) S0-D ( position exhaust center) S0-D (Individual EXH spacer) VS000-R-0- Manifold Option Parts ssembly Individual SUP spacer n individual SUP spacer set on manifold block can form SUP port for every valve. ody type Part no. Individual EXH spacer n individual EXH spacer set on manifold block can form EXH port for every valve. (common EXH type) ody type Part no. SUP block disk When supplying manifold with more than two different pressures, high and low, insert a block disk in between stations subjected to Plug-in different pressures. ody type Part no. EXH block disk When valve exhaust affects the other stations on the circuit or when a reverse pressure valve is used to a standard manifold valve, insert EXH block disk in between stations to separate valve exhaust. ody type Part no. EXH block disk VS000-P-0- VS000-R-0- Non plug-in type VS000-P-0- Non plug-in type VS000-R-0- Non plug-in type XT6-0 Non plug-in type XT6- SUP block disk Manifold Specifications ase model VS-0 Non plug-in type VS-0 Flow Characteristics at the Number of Manifold (Operated individually) Model VS Throttle valve spacer Needle valve set on the manifold block can control cylinder speed by throttling exhaust. ody type Part no. ody type Part no. VS VS000-- Non plug-in type VS Non plug-in type VS000-- ody type Non plug-in type P port regulation RF00-00-P- RF00-00-P- reduced pressure RF RF reduced pressure RF RF lanking plate It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. ody type Part no. Wiring With terminal block With multi-connector With D-sub connector DIN terminal Grommet terminal Non plug-in type VS000-0 Porting specifications, port Side/ ottom With multi-connector, or with D-sub connector: 8 stations max. / (P /) / / (/ R/R) Port size: Rc / Port size Rc P, E, E, 8, to 0 pplicable valve model S00-F S0-D S0-E Passage/ Station Station Station 0 C [dm /(s bar)] b Cv... C [dm /(s bar)] b Cv Double check spacer If the double check spacer with a built-in double check valve is combined, it will enable the cylinder to stop in the intermediate stroke and maintain its position for a long time without being affected by the leakage between the spools. Interface regulator Interface regulator set on manifold block can regulate the pressure to each valve. (Refer to page -8-6 for Flow Characteristics.) Manifold Option With exhaust cleaner /Non Valve exhaust noise dampening: d or more. Oil mist collection: Rate of collection 99.9% or more. Piping process reduced. For details, refer to page With control unit /Non Filter, regulation valve, pressure switch and air release valve are all combined to form one unit. Piping processes are eliminated. For details, refer to page With serial interface unit for serial transmission Solenoid valve wiring process reduced considerably. Disperse installation possible. Manifold solenoid valve: 8 stations max. positions ( solenoids). Maintenance and inspection are easy. For details, refer to Serial Transmission catalog separately.

227 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S Manifold, Non plug-in type (With terminal block): VS-0T- Station - Port size n-rc 8 U side Pilot valve manual override L ottom ported: VS-0T- Station - Port size Formula for manifold weight M = 0.6n (kg) n: Non plug-in type: VS-0- Station - Port size ottom ported: VS-0- Station - Port size Formula for manifold weight M = 0.78n (kg) L L n-rc Rc 8 (Pilot EXH port: PE) -G Electrical entry n: Formula L = x n + 70 L = x n + 8 G Cable ø8 to ø0 -Rc 8 (Pilot EXH port: PE) 6-Rc 6-Rc / Light D side (External pilot port) U side Light D side n-rc 8, -Rc 8 (External pilot port) -Rc 8 n-rc 8, Pilot valve manual override VP S S VS N -8-77

228 Series S Manifold with multi-connector/d-sub connector with multi-connector: VS-0CD- Station - Port size, VS-0CU- Station - Port size n-rc 8 U side Pilot valve manual override Light L ottom ported: CD VS-0 - Station - Port size with D-sub connector: VS-0FD- Station - Port size, VS-0FU- Station - Port size L L CU Formula for manifold weight M = 0.7n +.0 (kg) n: Station Wiring specifications: Refer to page n-rc 8 ottom ported: FD VS-0 - Station - Port size FU Formula for manifold weight M = 0.7n (kg) Wiring specifications: Refer to page n: Formula L = x n + 70 L = x n + 8 Plug assembly VS (Option: Refer to page -8-8.) -Rc 8 (Pilot EXH port: PE) Plug assembly VS000-- (Option: Refer to page -8-8.) -Rc 8 (Pilot EXH port: PE) 6-Rc D side n-rc 8, -Rc 8 (External pilot port) U side Light D side (External pilot port) Pilot valve manual override n-rc 8, -Rc

229 Manifold with Exhaust Cleaner Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S Serves to protect working environment. Valve exhaust noise dampening: d or more. Collection rate of drainage and oil mist: 99.9% or more. Piping work is reduced. U side Non plug-in type Exhaust cleaner (Option) D side Exhaust cleaner (Option) Caution When using an exhaust cleaner, mount it downwards. Refer to est Pneumatics Vol. for Exhaust Cleaner details. Manifold Specifications Wiring Manifold : VS-0 With terminal block With multi-connector With D-sub connector S00-F Non plug-in type: VS-0 DIN terminal Grommet terminal pplicable valve model S0-D, S0-E Common SUP/Common EXH Porting specifications (), () port Side: Rc /8, /, ottom: Rc /8 (Option) Rc (P), (R), (R) port P: Rc /, EXH: Rc, / to 0 () pplicable exhaust cleaners MC60-0 (Connecting port size R ), MC80- (Connecting port size R /) () Note ) With multi-connector, or with D-sub connector: 8 stations max. Note ) of or more and high frequency of operation should be used with MC80-. Exhaust cleaners MC60-0 and MC80- are not attached. VS Series S000 Manifold ase type/electrical entry 0T with terminal block 0C with multi-connector 0F with D-sub connector 0 Non plug-in type Connector mounting direction With connector pplicable base Nil None 0T, 0 D D side mounting 0C, 0F U U side mounting CD 0 stations 0 0 stations ase type 0T, 0: to 0 stations ase type 0C, 0F: to 8 stations <Example> with terminal block (6 stations) (Manifold base) VS-0T-06-0-CD ( position single) S00-FZ ( position double) S00-FZ (lanking plate) VS000-0 (Exhaust cleaner) MC60-0 Non plug-in type (6 stations) (Manifold base) ( position single) ( position double) (lanking plate) (Exhaust cleaner) How to Order VS CU S0-E S0-E VS000-0 MC80- Please indicate manifold base type, corresponding valve, and option parts. Nil N T F Option Port size P 0 Rc 0 M Exhaust cleaner mounting direction CD CU Rc NPT NPTF G D side U side D side mounting U side mounting Please indicate exhaust cleaner size or port size. Thread type, Rc 8 Rc Mixed For bottom ported, Rc 8 is only available. Exhaust Exhaust cleaner mounting direction Passage Porting specifications P R, R (, ) Side Common Common ottom Option VP S S VS N -8-79

230 Series S Manifold with Exhaust Cleaner, Non plug-in type : VS-0T- Station - Port size - CD CU U side Pilot valve manual override D side R, Non plug-in type: VS-0- Station - Port size - CD CU ( ): MC80 -Rc 8 (Pilot EXH port: PE) -G Electrical entry ( ): MC80 -Rc 8 6. ( 60) 6. ( 60) (Pilot EXH port: PE) D side Exhaust cleaner (Option) U side R, D side Pilot valve manual override Exhaust cleaner (Option) -Rc n-rc 8, -Rc 8 (External pilot port) -Rc (External pilot port) D side mounting n-rc 8, -Rc 8 D side mounting L L L Manual override U side Manual override U side U side mounting D side U side mounting n: Formula L = x n + 70 L = x n

231 Manifold with Control Unit Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 8 Control unit (Filter, Regulator, Pressure switch, ir release valve) are all standardized to the one unit, and can be mounted on the manifold base without any attachments. Piping processes are eliminated. Control Unit Specifications ir filter (With auto-drain/with manual drain) Filtration degree µm Regulator Set pressure (Outlet pressure) 0.0 to 0.8 MPa Pressure switch () Set pressure range: OFF 0. to 0.6 MPa Differential 0.08 MPa or less Contact a Indicator light LED (RED) Max. switch capacity V C, W DC VC/DC or less: 0 m Max. operating current 8 VC/DC: 0 m 00 VC/DC: 0 m ir release valve (Single only) Operating pressure range 0. to.0 MPa VS 0C D 08 0 P Series S000 Manifold ase type/electrical entry 0T with terminal block Control Unit/Option ir release () valve spacer Pressure switch lanking plate Filter element <> VS000--R (D side mounting) <Non plug-in type> VS000--R (D side mounting) IS000P-- Filter regulator Pressure switch Release valve 0- MP- MP- VS Note ) Voltage: VDC to 00 VC Inner voltage drop: V Note ) Combination of a valve S (single) and a release valve spacer can be used as an air release valve. Note ) The non plug-in type cannot be mounted afterwards. ir release valve coil rating Nil None (F, G type only) 00 VC, 0/60 Hz VDC 9 Other 0C with multi-connector Control unit type 0F with D-sub connector 0 Non plug-in type Nil P M MP F Control equipment Connector mounting direction ir filter with auto-drain G C E With connector pplicable base ir filter with manual drain Nil None 0T, 0 Regulator D D side mounting ir release valve 0C, 0F U U side mounting Pressure switch lanking plate (ir release valve) 0 stations lanking plate (Filter, Regulator) lanking plate (Pressure switch) 0 Passage Porting 0 stations specifications Number of manifold blocks P R, R (, ) required for mounting (stations) Side Common Common ottom ase type 0T, 0: to 0 stations ase type 0C, 0F: to 8 stations Non plug-in type Caution When using an air filter with auto-drain or manual drain, mount the filter vertically. Option Port size P, R, R, 0 Rc Rc 0 Rc M Mixed For bottom ported, Rc 8 is only available. Manifold Specifications Wiring Manifold pplicable valve model Porting specifications Rc How to Order Thread type 8 Nil Rc N T F Option NPT NPTF G : VS-0 With terminal block With multi-connector With D-sub connector S00-F (), () port (P), (R), (R) port With multi-connector, or with D-sub connector: 8 stations max. Please indicate manifold base type, corresponding valve, and option parts. <Example> with terminal block: In order to mount control unit, it requires stations. (Manifold base) ( position single) ( position double) VS-0T-08-0-P S00-FZ S00-FZ Non plug-in type: In order to mount control unit, it requires stations. (Manifold base) ( position single) () Non plug-in type: VS-0 DIN terminal Grommet terminal S0-D, S0-E Common SUP, Common EXH Side: Rc /8, /, ottom: Rc /8 Side: Rc / to 0 VS S0-D VP S S VS N -8-8

232 Series S000 8 Manifold with Control Unit, Non plug-in type : VS-0T- Station - Port size -P Voltage for release valve Example for manifold Individual EXH spacer Pilot valve manual override Pilot valve manual override n-rc, 8 Double check spacer U side Individual SUP spacer -Rc 8 Pilot EXH port: PE -G / Electrical entry Non plug-in type: VS-0- Station - Port size -P Voltage for release valve -Rc 8 Pilot EXH port: PE (80.: -MP) (80.: -MP) 6-Rc 0 0 Pressure switch ir release valve D side Rc / (Po port) n-rc 8, Pilot valve manual override Pressure switch ir release valve -Rc 8 (External pilot port) U side D side Rc / (Po port) Rc -Rc 8 (External pilot port) L L L L (MP) L (P) ir filter regulator Control unit Example for manifold Pressure switch Outlet for check n: Formula L = x n L = x n L = x n L = x n + 98 ir release valve ir release valve ir filter regulator Control unit Individual EXH spacer Double check spacer Individual SUP spacer Pressure switch Outlet for check -8-8

233 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 8 Manifold Option Parts Individual SUP spacer: VS000-P-0- () VS000-P-0- (Non plug-in type), Non plug-in type Double check spacer: VS000-- () VS000-- (Non plug-in type) (7: With direct manual override) Individual SUP spacer Double check spacer Individual EXH spacer: VS000-R-0- () VS000-R-0- (Non plug-in type) (79: With direct manual override) Individual EXH spacer SUP block disk: XT6-0 EXH block disk: XT6- Throttle valve spacer: VS () VS (Non plug-in type) (7: With direct manual override) Throttle valve spacer lock disk mounting position ( ): EXH block disk Interface regulator/p port regulation: RF00-00-P- () RF00-00-P- (Non plug-in type) (9: With direct manual override) Interface regulator Interface regulator/ port regulation: RF () RF (Non plug-in type) (9: With direct manual override) Interface regulator Interface regulator/ port regulation: RF () RF (Non plug-in type) (9: With direct manual override) Interface regulator VP S S VS N -8-8

234 Series S000 8 Manifold ase Construction, Non End plate (D side) Replacement Parts No. q w e r t y u i o! Description Connection fitting Connection fitting Gasket Gasket Gasket O-ring O-ring Terminal assembly Junction cover assembly Rubber plug Material Steel plate Steel plate NR NR NR NR NR For 0T For 0SU NR Replacement Parts: Sub ssembly End plate (U side) Part no. V000-- V000-- V000-7 (End plate) V (Manifold block) V000-8 S68-0 P- V000-6 V000-- Z78-0- XT6-9 Manifold block For increasing the manifold bases, please order the manifold block assembly number of the principal part assembly!0. For plug-in type: The manifold base with terminal stand (integrated with a junction cover) is required with the o junction cover assembly. Note) Manifold ase/construction: with terminal block. No. Description ssembly part no. Component parts pplicable manifold base!0!! Manifold block V Manifold block!0, Terminal i, Metal joint q, w, 0 Gasket r, Receptacle assembly assembly V Manifold block!0, Metal joint q, w, Gasket r Non plug-in type 0 0 End plate (D)!, Metal joint q, w, Gasket e, t, V000-- End plate (D side) O-ring y, u assembly End plate (D)!, Metal joint q, w, Gasket e, t, V000-- O-ring t, y Non plug-in type End plate (U side) assembly V000-- V000-- End plate (U)!, Metal joint q, w End plate (U)!, Metal joint q, w Non plug-in type -8-8

235 For details about certified products conforming to international standards, visit us at 8 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 Model position position Type of actuation Single Double Closed center Exhaust center Pressure center Double check Plug-in S00 S00 S00 S00 S00 S600 Model Non plug-in S0 S0 S0 S0 S0 S60 Port size Rc Flow characteristics / (P /) / / (/ R/R) C C [dm /(s bar)] b Cv [dm /(s bar)] b Cv Note ) ased on JIS 87 (once per 0 days) for the minimum operating frequency. Note ) ased on JIS (The value at supply pressure 0. MPa.) Note ) The figures in the above list are without sub-plate. In the case of with plug-in sub-plate and, with non plug-in sub-plate add /8, /0.7 kg, /0.966 kg and /8, /0.77 kg, /0.8 kg respectively. Note ) Note ) and Note ) are with controlled clean air. Compact yet provides a large flow capacity /: C: 0 dm /(s bar) Low power consumption:.8 W DC Easy maintenance types of sub-plates: Plug-in and non plug-in Non plug-in type JIS position Single Double position Closed center Exhaust center Pressure center Double check Standard Specifications Valve specifications Electricity specifications Fluid Maximum operating pressure Minimum operating pressure Proof pressure mbient and fluid temperature Lubrication Pilot valve manual override Shock/Vibration resistance Enclosure Coil rated voltage llowable voltage fluctuation Coil insulation type pparent power (Power consumption) C Power consumption DC Electrical entry Option Specifications Inrush Holding or less or less or less or less or less 60 or less ir/inert gas.0 MPa 0. MPa. MPa 0 to 60 C () Non-lube () Non-locking push type (Flush) 0/0 m/s () Type E: Dustproof (Level 0), Type F: Dripproof (Level ), Type D: Splashproof (Level ) () 00, 00 VC, 0/60 Hz; VDC to +0% of rated voltage Class or equivalent (0 C) ().6 V/0 Hz,.0 V/60 Hz. V (. W)/0 Hz,. V (. W)/60 Hz.8 W (.0 W: With light/surge voltage suppressor) Non plug-in type Conduit terminal Grommet terminal, DIN terminal Note ) Use dry air at low temperatures. Note ) Use turbine oil Class (ISO VG), if lubricated. Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Note ) ased on JIS C 090. Note ) ased on JIS C 00. Pilot type Manual override Main valve Pilot valve Coil rated voltage Porting specifications Option Note) Operating pressure: 0 to.0 MPa Pilot pressure: 0. to.0 MPa Max. operating cycle (cpm) Response time (ms) Weight (kg) External pilot Note) Direct manual override Non-locking push type (Extended), Locking type (Tool required), Locking type (Lever) 0 to 0, 0, 0 VC (0/60 Hz), 00 VDC ottom ported With light/surge voltage suppressor, Non-rotating DIN terminal () () () -8-8 VP S S VS N

236 Series S ody type O: sub-plate How to Order Electrical entry F: conduit terminal Porting specifications Nil Side ported ottom ported In the case of external pilot (Option), bottom piping is not available. Plug-in S 0 0 F 0 Port size Nil Without sub-plate 0 Rc 8 0 Rc 06 Rc Thread type Nil N T F Option Rc NPT NPTF G Non plug-in position single position double position closed center position exhaust center S 6 position pressure center position double check : Non plug-in type sub-plate 0 ody type ody option 0 Standard Direct manual override Option Pilot type Nil R Option D Coil rated voltage 6 7 Option Nil Z P ZP Electrical entry 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 to 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC VDC 0 VC, 0/60 Hz 9 Other Option Internal pilot External pilot 06 None With light/surge voltage suppressor Non-rotating DIN terminal Light/Surge Voltage Suppressor Non-rotating DIN terminal Type P, ZP is available for DIN type only. E: Grommet terminal D: DIN terminal SF F 0 Pilot valve Manual override Nil: Non-locking push type (Flush) : Non-locking push type (Extended) : Locking type (Tool required) C : Locking type (Lever) Option How to Order Pilot Valve ssembly Coil rated voltage 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 to 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC 6 VDC 7 0 VC, 0/60 Hz 9 Other Option Refer to page -8- for voltage conversion. Manual override Nil C Option Non-locking push type (Flush) Non-locking push type (Extended) Locking type (Tool required) Locking type (Lever) -8-86

237 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S Cylinder Speed Chart Use as a guide for selection. Please confirm the actual conditions with SMC Sizing Program. Series S00-06 Conditions S00-06 Can hold an intermediate cylinder position for an extended time If the double check spacer with a built-in double check valve is combined, it will enable the cylinder to stop in the intermediate stroke and maintain its position for a long time without being affected by the leakage between the spools. verage speed (mm/s) Tube bore x Length Speed controller Silencer ore size Series CS Pressure 0. MPa Load factor 0% Stroke 00 mm ø ø0 ø60 ø80 ø00 ø0 ø00 It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. Load factor: ((Load weight x 9.8)/Theoretical force) x 00% Double check spacer Non plug-in type Series CS SGP0 x m S00-06 N00-06 Double Check Spacer/Specifications Specifications Double check spacer part no. pplicable valve model Leakage (cm /min) Caution VS000-- S00-F Solenoid one side energized Solenoid both sides de-energized Supply pressure: 0. MPa Perpendicular, upward actuation Horizontal actuation Non plug-in type VS000-- S0-D S0-E In the case of position double check valve (S60), check the leakage from piping and fittings in between valve and cylinder by means of synthetic detergent solutions, and ensure that there is no such leakage found there. lso check the leakage from cylinder seal and piston seal. If there is any leakage, sometimes the cylinder, when valve is de-energized, can move without stopping at intermediate position. e aware that if the exhaust side is restricted excessively, the intermediate stopping accuracy will decrease and will lead to improper intermediate stops. P P R 0 R or less R 0 R or less R 0 R Check Valve Operation SUP side pressure P (MPa) Piston Cylinder side pressure Operating range The combination of S 0, S 0 and a double check spacer can be used as prevention of falling at the stroke end but cannot hold the intermediate position of the cylinder. 0 Check valve SUP side pressure (P) Cylinder side pressure P (MPa) 0 VP S S VS N -8-87

238 Series S Construction position single position double Component Parts No. q w e r t y u i Description ody Sub-plate Spool/Sleeve dapter plate End plate Piston Junction cover Light cover Replacement Parts Closed center Exhaust center Pressure center Material luminum die-casted luminum die-casted Stainless steel luminum die-casted luminum die-casted Resin Resin Resin position closed center/exhaust center/pressure center Note Platinum silver Platinum silver lack lack Sub-plate ssembly Part No. 0 Plug-in S000-P Non plug-in S000-S Mounting bolt and gasket are not included. Part no. for mounting bolt and gasket G-S000 No. Description Material Part no. S S S// o!0 Return spring Gasket Stainless steel NR S000-9 XT67-0- XT67-0- XT67-8 XT67-0-! Hexagon socket head screw Steel M x 0 M x 0 M x 0! Detent assembly XT0-9! Pilot valve assembly Refer to How to Order Pilot Valve ssembly on page

239 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S Plug-in position single/double, position closed center/exhaust center/pressure center/double check position single: S00-F -ø7 mounting hole ottom ported -Rc /8, /, / (R), (R): Rc / Pilot valve manual override With light/surge voltage suppressor Direct manual override G / electrical entry position double: S00-F position closed center: S00-F position exhaust center: S00-F position pressure center: S00-F Pilot valve manual override Direct manual override G / electrical entry ( ): Rc / 9. (8) position 7. (6) -Rc /8, /, / -ø7 mounting hole With light/surge voltage suppressor Rc /8 external pilot (Port size: Rc /8, /) Rc 8 (Pilot EXH port) position double check: S600-F Pilot valve manual override Direct manual override G / electrical entry -Rc /8, /, / -Rc /8, /, / ( ): Rc / (), () port Rc /8 external pilot (Port size: Rc /) -ø7 mounting hole ( ): Rc With light/surge voltage suppressor VP S S VS N -8-89

240 Series S Non Plug-in position single/double, position closed center/exhaust center/pressure center/double check position single: S0-E, S0-D -ø7 mounting hole -Rc /8, /, / Rc /: (R), Rc /: (R) G pplicable cabtire cable O.D. ø8 to ø0 Pilot valve manual override Direct manual override position double: S0-E, S0-D position closed center: S0-E, S0-D position exhaust center: S0-E, S0-D position pressure center: S0-E, S0-D G pplicable cabtire cable O.D. ø8 to ø0 Pilot valve manual override Direct manual override 0. ( position: 09.) -Rc 8,, -ø7 mounting hole ( ): Rc / position double check: S60-E, S60-D pplicable cabtire cable O.D. ø8 to ø0 Pilot valve manual override Direct manual override Rc /8 external pilot (Port size Rc /8, /) -Rc /8 (Pilot EXH port) Rc /8 external pilot (Port size: Rc /) -Rc 8,, -Rc 8,, ( ): Rc / ( ): Rc / G (), () port -ø7 mounting hole -8-90

241 9 Series S000 Manifold Specifications Plug-in Type: With Terminal lock Since lead wires of solenoid valve are connected with the terminals on upper surface of terminal block, corresponding lead wires from power source can be wired at the bottom of terminal block. Plug-in Type: With Multi-connector (Wiring specifications: Refer to page -8-8.) Master connection of power and solenoid valves. VS 0C Quick wiring permits easier installation. Series S000 0 stations Manifold U side Multi-connector Wiring for every valve. D side VS Series S000 Manifold with terminal block with multi-connector Wide range of interchangeability (MIL Spec. D-sub connector terminal VS pcs attached.) Quick wiring permits easier Series S000 installation. Manifold U side with D-sub connector VS Series S000 Manifold Non plug-in type 0T 0 stations 0F 0 D 06 0 D 0 Plug-in Type: With D-sub Connector (Wiring specifications: Refer to page -8-8.) D-sub connector D side Non Plug-in Type: Grommet Terminal, DIN Terminal Grommet terminal DIN terminal Plug assembly (Option) Refer to page Plug assembly (Option) Refer to page Connector mounting direction Connector mounting direction D U D U 0 0 stations Passage Porting specifications P R, R (, ) Side Common Common ottom D side mounting U side mounting D side mounting U side mounting 06 0 stations 0 stations 0 Option 08 8 stations Max. 8 stations Passage Porting specifications P R, R (, ) Side Common Common ottom Port size stations Max. 8 stations Passage Porting specifications P R, R (, ) Side Common Common ottom 0 stations M Passage Porting specifications P R, R (, ) Side Common Common ottom Option 0 06 M Nil P, R, R, N Rc T Rc Rc F Mixed Option For bottom ported, Rc is only available. Port size 0 06 M Option Nil P, R, R, N Rc T Rc Rc F Mixed Option For bottom ported, Rc is only available. 0 Port size 0 06 M Option Port size 0 06 Nil P, R, R, N Rc T Rc Rc F Mixed Option For bottom ported, Rc is only available. P, R, R, Rc Rc Rc Mixed For bottom ported, Rc is only available. Thread type Rc NPT NPTF G Thread type Rc NPT NPTF G Thread type Rc NPT NPTF G Thread type Nil N T F Option Rc NPT NPTF G -8-9 VP S S VS N

242 Series S000 9 How to Order Manifold ssembly Please indicate manifold base type, corresponding valve, and option parts. <Example> with terminal block: 6 stations (Manifold base) VS-0T-06-0 ( position single) S00-FZ ( position double) S00-FZ (lanking plate) VS000-0 Non plug-in type: 6 stations (Manifold base) VS ( position single) S0-D ( position exhaust center) S0-D (Individual EXH center) VS000-R-0- Manifold Specifications ase model VS-0 Non plug-in type VS-0 Wiring With terminal block With multi-connector With D-sub connector DIN terminal Grommet terminal Port size Rc, port P, R, R, Rc Rc, With multi-connector, or with D-sub connector: 8 stations max. S00-F S0-D S0-E Flow Characteristics at the Number of Manifold (Operated individually) Model VS Passage/ / (P /) / / (/ R/R) Port size: Rc /, / C [dm /(s bar)] 6.0 b 0.0 Cv C [dm /(s bar)] b Cv Porting specifications Side/ ottom to 0 pplicable valve model Station Station Station Manifold Option Parts ssembly Individual SUP spacer n individual SUP spacer set on manifold block can form SUP port for every valve. ody type Part no. Individual EXH spacer n individual EXH spacer set on manifold block can form EXH port for every valve. (common EXH type) ody type Part no. SUP block disk When supplying manifold with more than two different pressures, high and low, insert a block disk in between stations subjected to different pressures. ody type Part no. EXH block disk When valve exhaust affects the other stations on the circuit or when a reverse pressure valve is used on a standard manifold valve, insert EXH block disk in between stations to separate valve exhaust. ody type Part no. EXH block disk VS000-P-0- VS000-R-0- Non plug-in type VS000-P-0- Non plug-in type VS000-R-0- Non plug-in type XT68- Non plug-in type XT-- SUP block disk Throttle valve spacer Needle valve set on the manifold block can control cylinder speed by throttling exhaust. ody type Non plug-in type Part no. VS VS Double check spacer If the double check spacer with a built-in double check valve is combined, it will enable the cylinder to stop in the intermediate stroke and maintain its position for a long time without being affected by the leakage between the spools. ody type Non plug-in type Part no. VS000-- VS000-- Interface regulator Interface regulator set on manifold block can regulate the pressure to each valve. (In the event of using, refer to Flow Characteristics on page -8-6). ody type P port regulation port regulation port regulation RF00-00-P- RF RF Non plug-in type RF00-00-P- RF RF lanking plate It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. ody type Part no. Non plug-in type VS000-0 Manifold Option With exhaust cleaner /Non plug-in type Valve exhaust noise dampening: d or more. Oil mist collection: Rate of collection 99.9% or more. Piping process reduced. For details, refer to page With serial interface unit for serial transmission Solenoid valve wiring process reduced considerably. Disperse installation possible. Manifold solenoid valve: 8 stations max. positions ( solenoids). Maintenance and inspection are easy. For details, refer to Serial Transmission catalog separately. -8-9

243 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 9 Manifold, Non plug-in type (With terminal block): VS-0T- Station - Port size Direct manual override U side Pilot valve manual override L ottom ported: VS-0T- Station - Port size Formula for manifold weight M = 0.9n +.6 (kg) n: Station ( ): ()/() port Rc Non plug-in type: VS-0- Station - Port size DIN terminal VS-0- Station - Port size L L Pitch P = n-rc Pitch P = n-rc pplicable cabtire cable O.D. ø8 to ø Rc G Electrical entry 9 69 Direct manual override Pilot valve manual override G Formula L = x n + 9 L = x n Rc -Rc 8 (External pilot) -Rc 8 (Pilot EXH) D side -Rc 8 (External pilot) -Rc 8 (Pilot EXH) n-rc /, / U side D side n-rc, Grommet with terminal 6-Rc -Rc 8 (External pilot) -Rc 8 (Pilot EXH) Formula for manifold weight M = 0.8n +. (kg) n: Station ( ): ()/() port Rc VP S S VS N -8-9

244 Series S000 9 Manifold with multi-connector/d-sub connector with multi-connector: VS-0CD- Station - Port size, VS-0CU- Station - Port size Direct manual override Pilot valve manual override U side Pitch P = L ottom ported: CD VS-0 - Station - Port size with D-sub connector: VS-0FD- Station - Port size, VS-0FU- Station - Port size L L n-rc 9 6 CU Formula for manifold weight M = 0.96n (kg) n: Station Refer to page For wiring specifications. Pitch P = n-rc ottom ported: FD VS-0 - Station - Port size FU Formula for manifold weight M = 0.96n +.6 (kg) n: Station Refer to page For wiring specifications Plug assembly VS (Option: Refer to page -8-8.) Pilot valve manual override Direct manual override Plug assembly VS000-- (Option: Refer to page -8-8.) Formula L = x n + 9 L = x n + 0 -Rc 8 (Pilot EXH) 6-Rc D side U side D side n-rc, -Rc 8 (External pilot) n-rc, -Rc 8 (External pilot) -Rc 8 (Pilot EXH) ( ): ()/() port Rc ( ): ()/() port Rc -8-9

245 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S000 9 Manifold with Exhaust Cleaner Serves to protect working environment. Valve exhaust noise dampening: d or more. Collection rate of drainage and oil mist: 99.9% or more. Piping work is reduced. U side Non plug-in type Caution Exhaust cleaner (Option) Exhaust cleaner (Option) D side When using an exhaust cleaner, mount it downwards. Refer to est Pneumatics Vol. for Exhaust Cleaner details. Manifold Specifications Manifold : VS-0 Non plug-in type: VS-0 Wiring With terminal blocks DIN terminal With multi-connector With D-sub connector Grommet terminal pplicable valve model S00-F S0-D, S0-E Common SUP/Common EXH Porting specifications (), () port Side: RC /, /, ottom: Rc / (Option) Rc (P), (R), (R) port P: Rc /, EXH: Rc / to 0 () pplicable exhaust cleaners MC80- (Connecting port size R /) () Note ) With multi-connector, or with D-sub connector: 8 stations max. Note ) Exhaust cleaner: Not attached. VS Series S000 Manifold ase type/electrical entry 0T with terminal block 0C with multi-connector 0F with D-sub connector 0 Non plug-in type Connector mounting direction With connector pplicable base Nil None 0T, 0 D D side mounting 0C, 0F U U side mounting How to Order CD 0 stations 0 0 stations ase type 0T, 0: to 0 stations ase type 0C, 0F: to 8 stations Thread type Option Port size Exhaust cleaner mounting direction For bottom ported, Rc is only available. Passage Porting specifications P R, R (, ) Side Common Common ottom Option Please indicate manifold base type, corresponding valve, and option parts. <Example> with terminal block (6 stations) (Manifold base) VS-0T-06-0-CD ( position single) S00-FZ ( position double) S00-FZ (lanking plate) VS000-0 (Exhaust cleaner) MC80- Non plug-in type (6 stations) (Manifold base) ( position single) ( position double) (lanking plate) (Exhaust cleaner) 0 06 M Nil N T F P Rc VS CU S0-E S0-E VS000-0 MC80- Rc NPT NPTF G CD CU, Rc Rc Mixed Exhaust cleaner mounting direction D side D side mounting U side U side mounting VP S S VS N -8-9

246 Series S Manifold with Exhaust Cleaner, Non plug-in type : VS-0T- Station - Port size - CD CU Direct manual override Pilot valve manual override U side n-rc, D side R 0 ( ): ()/() port Rc / Non plug-in type: VS-0- Station - Port size - CD CU 0 ( ): ()/() port Rc / MC80- Exhaust cleaner (Option) Direct manual override Pilot valve manual override -G / Electrical entry Exhaust cleaner (Option) -Rc 8 D side D side -Rc / U side R -Rc n-rc, D side mounting D side mounting L L L U side U side mounting D side U side U side mounting n: Formula L = x n + 9 L = x n

247 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S Manifold Option Parts Individual SUP spacer: VS000-P-0- () VS000-P-0- (Non plug-in type), Non plug-in type Double check spacer: VS000-- () VS000-- (Non plug-in type) Individual SUP spacer Rc Double check spacer Individual EXH spacer: VS000-R-0- () VS000-R-0- (Non plug-in type) Individual EXH spacer SUP block disk: XT68- EXH block disk: XT-- lock disk mounting position Throttle valve spacer: VS () VS (Non plug-in type) Throttle valve spacer Rc ( ) : SUP block disk Interface regulator/p port regulation: RF00-00-P- () RF00-00-P- (Non plug-in type) Interface regulator Interface regulator/ port regulation: RF () RF (Non plug-in type) Interface regulator Interface regulator/ port regulation: RF () RF (Non plug-in type) Interface regulator VP S S VS N -8-97

248 Series S Manifold ase Construction, Non plug-in type End plate (D side) Replacement Parts No. q w e r t y u i o! Description Connection fitting Connection fitting O-ring O-ring O-ring O-ring O-ring Terminal assembly Junction cover assembly Rubber plug Material Steel plate Steel plate NR NR NR NR NR For 0T For 0SU NR Replacement Parts: Sub ssembly No.!0!! Description Manifold block assembly End plate (U side) assembly End plate (D side) assembly Manifold block End plate (U side) Part no. XT68-6- XT68-6- S S68-00 S68-0 S68-0 S68-06 XT68-- VS000-- Z78-- XT6-9 ssembly part no. VS VS VS000-- VS000-- VS000-- VS For increasing the manifold bases, please order the manifold block assembly number of the principal part assembly!0. For plug-in type: The manifold base with terminal stand (integrated with a junction cover) is required with the o junction cover assembly. Note) Manifold ase/construction: with terminal block. Component parts Manifold block!0, Metal joint q, w, Terminal i, O-ring e, r, t, y, u, Receptacle assembly Manifold block!0, Metal joint q, w, O-ring e, r, t, y, u End plate (U)!, Metal joint q, w End plate (U)!, Metal joint q, w End plate (D)!, Metal joint q, w, O-ring e, r, t, y, u End plate (D)!, Metal joint q, w, O-ring e, r, t, y, u pplicable manifold base Non plug-in type Non plug-in type Non plug-in type -8-98

249 For details about certified products conforming to international standards, visit us at 99 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S6000 Model position Type of actuation Plug-in Model Non plug-in Port size Rc Single S600 S or less. Double S600 S or less.7 Note ) ased on JIS (once per 0 days) for the min. operating frequency. Note ) ccording to JIS (The value at supply pressure 0. MPa.) Note ) The figures in the above list are for without sub-plate. In case of with sub-plate, add.6 kg for Rc / and. kg for RC respectively. Note ) Note ) and Note ) are with controlled clean air. Note ) The flow characteristics is for the port size Rc /. Compact yet provides a large flow capacity /: C: 8 dm /(s bar) Low power consumption:.8 W DC Easy maintenance types of sub-plates: Plug-in and non plug-in JIS position Single Double Flow characteristics / (P /) / / (/ R/R) C C [dm /(s bar)] b Cv [dm /(s bar)] b Cv Standard Specifications Valve specifications Electricity specifications Fluid Maximum operating pressure Minimum operating pressure Proof pressure mbient and fluid temperature Lubrication Pilot valve manual override Shock/Vibration resistance Enclosure Coil rated voltage llowable voltage fluctuation Coil insulation type pparent power C (Power consumption) Power consumption DC Electrical entry Option Specifications Inrush Holding ir/inert gas.0 MPa 0. MPa. MPa 0 to 60 C () Non-lube () Non-locking push type (Flush) 0/0 m/s () Type E: Dustproof (Level 0), Type F: Dripproof (Level ), Type D: Splashproof (Level ) () 00, 00 VC, 0/60 Hz; VDC to +0% of rated voltage Class or equivalent (0 C) ().6 V/0 Hz,.0 V/60 Hz. V (. W)/0 Hz,. V (. W)/60 Hz.8 W (.0 W: With light/surge voltage suppressor) Conduit terminal Non plug-in type Grommet terminal, DIN terminal Note ) Use dry air at low temperatures. Note ) Use turbine oil Class (ISO VG), if lubricated. Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Note ) ased on JIS C 090. Note ) ased on JIS C 00. Pilot type Manual override Main valve Coil rated voltage Porting specifications Option Note) Operating pressure: 0 to.0 MPa Pilot pressure: 0. to.0 MPa Note) Max. operating cycle (cpm) Response time (ms) Weight (kg) External pilot Direct manual override 0 to 0, 0, 0 VC (0 Hz/60 Hz), 00 VDC ottom ported With light/surge voltage suppressor, Non-rotating DIN terminal () () () VP S S VS N -8-99

250 Series S How to Order ody type O: sub-plate Electrical entry F: conduit terminal Porting specifications Nil Side ported ottom ported In the case of external pilot (Option), bottom piping is not available. Port size Nil Without sub-plate 06 Rc 0 Rc Thread type Nil N T F Option Rc NPT NPTF G Plug-in S6 0 0 F Z 0 Non plug-in S6 position single position double : Non plug-in type sub-plate Option ody type ody Option 0 Standard Direct manual override 0 Pilot type Nil R Option D Coil rated voltage 6 7 Z Internal pilot External pilot Option Nil Z Electrical entry 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 to 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC VDC 0 VC, 0/60 Hz 9 Other Option 0 None With light/surge voltage suppressor E: Grommet terminal D: DIN terminal How to Order Pilot Valve ssembly SF F Coil rated voltage 00 VC, 0/60 Hz 00 VC, 0/60 Hz 0 to 0 VC, 0/60 Hz 0 VC, 0/60 Hz VDC 6 VDC 7 0 VC, 0/60 Hz 9 Other Option Refer to page -8- for voltage conversion

251 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S Cylinder Speed Chart Construction Component Parts Replacement Parts position single position double No. Description Material Note q w e ody Sub-plate Spool/Sleeve luminum die-casted luminum die-casted Stainless steel Platinum silver Platinum silver r dapter plate luminum die-casted lack t End plate luminum die-casted lack y Piston Resin u Junction cover Resin i Light cover Resin No. o!0!! Series S600-0 Conditions S600-0 Description verage speed (mm/s) Use as a guide for selection. Please confirm the actual conditions with SMC Sizing Program. ore size Series CS Pressure 0. MPa Load factor 0% Stroke 00 mm ø ø0 ø60 ø80 ø00 ø0 ø00 It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. Load factor: ((Load weight x 9.8)/Theoretical force) x 00% Series CS Tube bore x Length SGP x m Speed controller S600-0 Silencer N600-0 Material Sub-plate ssembly Part No. Part no. Perpendicular, upward actuation Horizontal actuation Plug-in S6000-P Non plug-in S6000-S- 0 Mounting bolt and gasket are not included. Part no. for mounting bolt and gasket G-S6000 S6 S6 Return spring Stainless steel S Gasket NR S6000- S6000- Detent assembly S Pilot valve assembly Refer to How to Order Pilot Valve ssembly on page VP S S VS N -8-0

252 Series S Plug-in position single/double position single: S600-F Pilot valve manual override -ø9 mounting hole Solenoid valve mounting bolt (Hexagon socket head cap screw) -M8 x 80 with SW Light window (FZ) G / electrical entry -Rc /8 pilot EXH port position double: S600-F Pilot valve manual override G / electrical entry -Rc /8 pilot EXH port -Rc, -ø9 mounting hole Light window (FZ) Solenoid valve mounting bolt (Hexagon socket head cap screw) -M8 x 80 with SW -Rc, (, port) Rc /8 external pilot port (S600R) (, port) Rc /8 external pilot port (S600R) -8-0

253 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series S Non Plug-in position single/double position single: S60-E, S60-D Light window (EZ, DZ) Pilot valve manual override pplicable cabtire cable O.D. ø8 to ø0 -Rc /8 pilot EXH port position double: S60-E, S60-D pplicable cabtire cable O.D. ø8 to ø0 -Rc /8 pilot EXH port G G -ø9 mounting hole Solenoid valve mounting bolt (Hexagon socket head cap screw) -M8 x 80 with SW -Rc, Light window (EZ, DZ) Pilot valve manual override -ø9 mounting hole Solenoid valve mounting bolt (Hexagon socket head cap screw) -M8 x 80 with SW -Rc, (, port) Rc /8 external pilot port (S60R) (, port) Rc /8 external pilot port (S60R) VP S S VS N -8-0

254 Direct Operated Solenoid Valve Metal Seal Series VS 0 Model Number of positions (Single) (Double) ( position) JIS Model VS0-0 VS0-0 VS0-0 VS0-0 VS0-0 VS0-0 VS0-0 VS0-0 (Closed center) VS0-0 VS0-0 VS0-0 (Exhaust center) VS0-0 Port size Rc (Nominal size) 8 (6) (8) (0) 8 (6) 8 (8) (0) 8 (6) 8 (8) (0) 8 (6) 8 (8) (0) 8 C [dm /(s bar)] P / b Note ) Min. operating frequency is once every 0 days. (ased on JIS 87.) Note ) ased on JIS (t the pressure of 0. MPa, without surge suppressor) Note ) Electrical entry: From sub-plate Note ) Note ) and Note ) are with controlled clean air. Caution For Safety Instructions and Solenoid Valve Precautions, refer to page --. How to Calculate the Flow Rate For obtaining the flow rate, refer to page VS Direct operated/metal seal solenoid valve, port valve Type of actuation Single Double position (Closed center) position (Exhaust center) Standard Specifications Solenoid Specifications Flow characteristics Max. () Response operating () () Weight (kg) / E/E cycle (cpm) time (ms) Cv C [dm /(s bar)] b Cv C DC C DC C DC Fluid Operating pressure range mbient and fluid temperature Manual override Electrical entry ,00 80, or less or less or less or less ir/inert gas 0 to.0 MPa 0 to 60 C or less 0 or less or less or less Possible Grommet, Conduit, DIN terminal, Conduit terminal Non-lube Usable with non-lude Lubrication Lubrication Use turbine oil Class (ISO VG), if lubricated. Impact/Vibration resistance (m/s ) 0/0 Note) Manifold Possible Use dry air (Dew point: 0 C or less). If using a lubricant, be sure to use a lubricant for low temperatures. Note) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Coil rated voltage llowable voltage fluctuation Coil insulation type Note) ased on JIS C 00 How to Order 0 ody size: /8 standard Piping 0 Side ported Port size (Nominal size) ottom ported 00 Without sub-plate Without sub-plate 0 Rc / 8 (6) (For manifold) 0 Rc / (8) 0 Rc / 8 (0) 0 C L Voltage C T U D 00 VC, 0/60 Hz 00 VC, 0/60 Hz VDC 9 Other Electrical entry Electrical entry position Sub-plate Sub-plate Valve body Valve body 00, 00 VC, 0/60 Hz; VDC to +0% of rated voltage Class or equivalent (0 C) Note) Electrical entry Conduit Conduit with terminal Grommet DIN terminal ccessory L P Thread type Nil N T F Option Rc NPT NPTF Indicator light (DC is possible only for DL.) Manual override -9- VP S S VS N

255 Series VS0 pparent Power (Power Consumption) pparent power (V) (Power consumption (W)) C Inrush Holding 0 Hz 60 Hz 0 Hz 60 Hz V (6 V ) V ( V ) 7 V (./. W) V (.9/. W) ccessory (Option). Indicator light (C) When solenoid gets energized, indicator light illuminates, thus electrical states of the solenoid can be seen from the outside. Power consumption (W) DC. In the case of position type. Option Specifications ottom ported (Sub-plate) Coil rated voltage (0/0 VC, /00 VDC) Enclosure (ased on JIS C 090) Electrical entry Dustproof Dripproof Grommet Sub-plate/ Valve body Standard Construction Principle VS0 VS0 VS0 (Closed center) Conduit Standard Option DIN terminal Standard Option Conduit terminal Standard Option With rubber plug SC000- SC00- Manual override Non-locking With lock SC000- SC00- SC000- SC00- Indicate the voltage to be used. pplicable model VS0 VS0 VS0 VS0. Manual override Remove rubber plug at the top of the solenoid cap to install manual override. Push the override with a screwdriver to the required stroke and the valve will shift. With the override in the same position, turn it to the right or left 90 and it will lock. Turn it back 90 to unlock. Caution e sure to unlock it before energizing the valve electrically. Description Part no. pplicable model Manual override C P0 VS0 VS0 (With lock) DC P0- VS0 Manual override C P00 VS0 (Non-locking) DC P00- In the case of a position solenoid valve, use a non-locking manual override because it has a locking function in the main valve.. Terminal wiring Lead wire from the solenoid is connected to the lower terminal of the terminal block under the junction cover of sub-plate. Connect the lead wire of the power supply corresponding to the solenoid (single solenoid: side/double solenoid: both and sides) to the upper terminal of the terminal block. -9-

256 Direct Operated Solenoid Valve Metal Seal Series VS0 Construction VS0 VS0 Sub-plate ssembly Part No. C: Conduit Electrical entry T: Conduit terminal U: Grommet, D: DIN terminal Mounting bolt and gasket are not included. Part No. for Mounting olt and Gasket G-VS00 Part no. VS00-CS- VS00-TS- VS00-S VS0/0 Component Parts No. q w e Replacement Parts Part no. No. Description Material VS0 VS0 VS0/VS0 r t y Spring Rubber plug for wire Plug for cap Piano wire NR NR XT-9- XT00-0 XT-6 XT0- XT-6 XT-- XT0- XT-6 u Rubber plug NR XT- XT- XT- i Mounting bolt Carbon steel XT-7 XT-7 XT-7 o Mounting screw Carbon steel XT-9 (XT--) XT-9 (XT--) DXT00-6 (XT--)!0 Detent assembly NR XT-0! Gasket NR XT-- XT-- XT--! Gasket NR XT- XT- XT-! Gasket NR XT- XT- XT-! Gasket NR XT-7 ( ): For DC! Solenoid Capsule ssembly (With rubber plug) Standard Option ody Description Sub-plate Spool/Sleeve DIN terminal Specifications Grommet/Conduit Indicator light (C only) Indicate the used voltage. Material luminum die-casted luminum die-casted Stainless steel VS0/0 SC00- SCD00- SC00- Part no. Note Platinum silver Platinum silver VS0/0 SC0- SCD0- SC0- VP S S VS N -9-

257 Series VS0 Dimensions Grommet (VS0) (VS0) (VS0/0) Conduit Conduit terminal (VS0) (VS0) (VS0/0) DIN terminal (VS0) (VS0) (VS0/0) ottom ported (VS0) (VS0) (VS0/0) -9- ( ): DC

258 Series VVS0 Manifold Specifications Specifications pplicable valve Valve stations ccessory Option VS0/0/0/0 Max. 0 stations (Standard) With terminal With interface regulator With stop valve/with flow controls Conduit Grommet Conduit terminal Standard Piping Specifications Type Common EXH Individual EXH Configuration P Port size Rc, E, E, 8 8,, 8 (Side) (Side) (Side), 8 8, 8, (Side) (Side) (ottom) Conduit port size G, Optional piping: Individual SUP and different pressure SUP. ut it will be the bottom porting specifications. Note) Each port size will be a big size for standard. When the small size is desired, indicate separately. S Valve Manifold base pplicable valve series S 0 9 P Side Side VV VS0 pplicable valve way pplicable valve ase size: 8 Porting specifications, Side ottom Other Caution E, E Side Side How to Order 0 Valve stations 0 stations 0 0 stations 0 stations. SUP port and EXH port are positioned on both sides of manifold block. ir can be supplied from either side; however, the unused port must be plugged in this case. When operating 6 or more valve stations within a manifold at the same time, take SUP air pressure from both sides and open EXH port to the atmosphere. SC SU 0 SC Electrical entry Electrical entry position Manifold block Valve body Manifold specifications SUP EXH Common Common Common Individual Individual Common Individual Individual Dissimilar pressure Common 6 Dissimilar pressure Individual Precautions Mounting T Thread type Nil Rc N NPT T NPTF F Option ccessory T With terminal S With stop valve R With throttle valve Type SC only. e sure to read before handling. For Safety Instructions and Splenoid Valve Precautions, refer to page --.. When manifolding an exhaust center position valve, use the individual EXH style manifold. (ack pressure may cause actuator to malfunction.) -9- VP S S VS N

259 Series VVS0 6 Construction Dimensions Type SC ( ) Electrical entry position: Manifold block Type SU Electrical entry position: ( Valve body ) Replacement Parts: Sub-assembly No. q w e r t y No. u i o Replacement Parts Description Hexagon socket head screw Gasket O-ring Formula/ L = 8n + 7 L = 8n + Material Carbon steel NR NR Manifold Optional Parts ssembly Option lanking plate Throttle valve spacer Stop valve spacer Interface regulator lock disk Rubber plug -G, / Electrical entry SC (T only) Type SU Type SC Type SC Type SU Type SC Type SU Part no. M6 x XT-- S Formula for manifold weight M = 0.0n (kg) Formula/ L = 8n + 7 L = 8n + Description ssembly part no. XT Manifold block assembly XT XT XT End plate (U side) assembly 0 XT XT End plate (D side) assembly 0 XT Terminal assembly XT6- Junction cover assembly XT6-- Tie-rod XT6-- Part no. XT6-7 XT9 XT9 R0-00- XT6-6 XT (P port regulation) (/ port regulation) Formula for manifold weight M = 0.n (kg) -9-6 ( ): DC

260 ISO Standard Solenoid Valve: Size, Metal Seal/Rubber Seal Series -6/7-8 (Size ) (Size ) Conforms to ISO standard 99/I Interface conforms to ISO standard Size (-6) and Size (-8). Outstanding high speed response and long service life Enclosure IP6 compliant Dusttight/Low jetproof type wide variety of manifold options Manifolds can be configured with a wide range of interface options to meet a variety of application requirements. Lighter weight Size ( position) 0.8 kg % less (Compared with previous series) Size ( position) 0.7 kg % less Space-saving profile Installation space % reduction Installation volume 0% reduction (Compared with previous series) Choice of metal or rubber seal increases compatibility with various operating and environmental conditions. VP S S VS N -0-

261 Series -6/7-8 Precautions e sure to read before handling. For Safety Instructions and Solenoid Valve Precautions, refer to page --. Manual Override Operation Warning Since connected equipment will be actuated when the manual override is operated, first confirm that conditions are safe. Push type is standard. (Tool required) Push type (Tool required) Caution Series -6-8 Hole dia. ø7 Mounting of Valves Push down on the manual override button with a small screwdriver until it stops. Release the screwdriver and the manual override will return. fter confirming the gasket is correctly placed under the valve, securely tighten the bolts with the proper torque shown in the table below. Proper tightening torque (N m). to.7.0 to 6.0 Mounting bolt -6: M -8: M6 Installation and Removal of Pilot Valve Cover Caution Installation and Removal of Pilot Valve cover Removal To remove the pilot valve cover, spread the cover s hook outward about mm with a flat head screw driver, and pull the cover straight off. If it is pulled off at an angle, the pilot valve may be damaged or the protective O-ring may be scratched. Installation Put the cover back on straight without touching the pilot valve, and push it all the way until the cover s hook locks, without twisting the protective O-ring. (When pushed in, the hook opensand locks automatically.) Replacement of Pilot Valves Caution Removal. Remove the sockets which are installed on the pilot valve pins by pulling them straight upward.. Remove the pilot valve mounting screws with a small screwdriver. Installation. fter confirming installation of the gasket, securely tighten the mounting screws with the proper torque shown in the table below.. Put the sockets on straight and install them securely so that the receptacle housings touch the coil surface as shown in the drawing below. If they are pushed in with excessive force, there is a danger O-ring Pilot valve cover Mounting screw Socket of the sockets coming off of the receptacle housings. Confirm that the sockets do not protrude from the windows on the side of the receptacle housings. Proper tightening torque (N m) 0.08 to 0. Coil Receptacle Window -0-

262 Series -6/7-8 Precautions e sure to read before handling. For Safety Instructions and Solenoid Valve Precautions, refer to page --. How to Wire DIN Terminal Caution ISO#: DIN 60 compatible Connection. Loosen the top screw and remove the connector housing from the terminal spades on the solenoid.. Remove the housing screw and insert a screwdriver into the slot area on the underside of the DIN cap and carefully separate block and housing.. Loosen the terminal screws (slotted screws) on the terminal block, insert the core of the lead wire into the terminal in accordance with the prescribed connection method, and attach securely with the terminal screws.. Tighten the ground nut to secure the wire. Change of electrical entry (Orientation) fter separating terminal block and housing, the cord entry direction can be changed by attaching the housing in the desired direction ( directions in 90 increments). Precautions Pull a connector out vertically, never at an angle. pplicable cable O.D.: ø8 to ø0 Ground nut Washer Grommet (Rubber) Holding screw Housing Terminal block Using a Pre-wired Connector core wire round type connector (M) conforming to NEC (Nippon Electric Control Equipment Industries ssociation) standard 0 How to Calculate the Flow Rate For obtaining the flow rate, refer to page --0. SOL. SOL. Internal Wiring Specifications Caution SOL. SOL. SOL. SOL. ~ + ~ ~ + () ZNR () DC: Single ZNR () DIN terminal wiring specifications ~ COM () DC: Double 00 VC: Single 00 VC: Double 00 VC or more: Single ZNR ZNR () ~ + COM () ZNR ZNR () () COM () ZNR () () ZNR ZNR 00 VC or more: Double ~ ~ + ~ SOL. () () ~ + ~ ~ + ~ () () SOL. SOL. Terminal numbers in the circuits are for a DIN connector. Numbers inside ( ) are pre-wired connector pin numbers. Terminal no. : side SOL. : side SOL. : COM terminal Pre-wired connector wiring specifications Pin no. : COM. pin : side SOL. : Not in use : side SOL. VP S S VS N -0-

263 Cylinder Speed Chart Series -6-FG-S-0-6-FG-S-0 Series -6-FG-S-R0 verage speed (mm/s) verage speed (mm/s) Use as a guide for selection. Please confirm the actual conditions with SMC Sizing Program. ore size Series M Series CS Pressure 0. MPa Pressure 0. MPa Load factor 0% Load factor 0% Stroke 00 mm Cylinder stroke 000 mm ø0 ø0 ø6 ø80 ø00 ø ø0 ø60 ø80 ø FG-S-R It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. Load factor: ((Load weight x 9.8)/Theoretical force) x 00% Perpendicular, upward actuation Horizontal actuation ore size Series M Pressure 0. MPa Load factor 0% Stroke 00 mm Series CS Pressure 0. MPa Load factor 0% Cylinder stroke 000 mm ø0 ø0 ø6 ø80 ø00 ø ø0 ø60 ø80 ø00 Perpendicular, upward actuation Horizontal actuation -0-

264 Cylinder Speed Chart Series -8-FG-S-0-8-FG-S-R0-8-FG-S-0-8-FG-S-R0 Conditions verage speed (mm/s) ore size Series M Pressure 0. MPa Load factor 0% Stroke 00 mm Series CS Pressure 0. MPa Load factor 0% Cylinder stroke 000 mm ø0 ø6 ø80 ø00 ø ø0 ø60 ø80 ø00 ø0 ø00 It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. Load factor: ((Load weight x 9.8)/Theoretical force) x 00% ase mounted Series M Series CS -6-FG-S-0-6-FG-S-0-6-FG-S-R0-6-FG-S-R0 SGP (Steel pipe) dia. x Length Speed controller Silencer SGP (Steel pipe) dia. x Length Speed controller Silencer SGP (Steel pipe) dia. x Length Speed controller Silencer SGP (Steel pipe) dia. x Length Speed controller Silencer 6 x m S000-0 N x m S0-0 N x m S000-0 N x m S0-0 N00-0 Use as a guide for selection. Please confirm the actual conditions with SMC Sizing Program. Perpendicular, upward actuation Horizontal actuation ase mounted Series M Series CS -8-FG-S-0-8-FG-S-0-8-FG-S-R0-8-FG-S-R0 SGP (Steel pipe) dia. x Length Speed controller Silencer SGP (Steel pipe) dia. x Length Speed controller Silencer SGP (Steel pipe) dia. x Length Speed controller Silencer SGP (Steel pipe) dia. x Length Speed controller Silencer 0 x m S000-0 N00-0 x m S0-0 N x m S000-0 N00-0 x m S0-0 N00-0 VP S S VS N -0-

265 ISO Standard Solenoid Valve: Size Metal Seal/Rubber Seal, Single Unit Series -6 For details about certified products conforming to international standards, visit us at 6 How to Order Valves 6 FG FG YZ FHG FJG FPG FIG Passage symbol (R)(P)(R) (R)(P)(R) () () (R)(P)(R) () () S D ()() () () (R)(P)(R) () () (R)(P)(R) () () (R)(P)(R) Option Number of solenoids Single Double VS7 0 Port size 0 Side ported RC / 0 Side ported Rc /8 0 ottom ported Rc / 0 ottom ported Rc /8 Port (R) and (R) are Rc /8 S Option Nil Z V Coil rated 9 Seal Nil R 00 VC 00 VC VDC VDC Other voltages How to Order Sub-plate Thread type Nil Rc F G T NPTF Connector Nil O SC Sub-plate port size Nil For other voltages, please contact SMC separately. Without sub-plate Side ported Rc / Side ported Rc /8 ottom ported Rc / ottom ported Rc /8 Port R is Rc /8 Metal seal Rubber seal None Light/Surge voltage suppresor Individual pilot exhaust When two or more symbols are specified, indicate them alphabetically. Specifications Model VS7--0 VS7--0 VS7--0 VS7--0 Piping location Side ottom Porting specifications (P), (), () port size / / DIN terminal block (With connector) DIN terminal block (Without connector) Pre-wired connector /8 /8 (R), (R) port size /8 /8 Thread type Nil F T Rc G NPTF Weight (kg)

266 ISO Standard Solenoid Valve: Size Metal Seal/Rubber Seal Series -6 7 Model Series -6 Single Double Closed center Exhaust center Double check Pressure center Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Model JIS position single position double (Metal) () () (R)(P)(R) () () (R) (P)(R) position double (Rubber) position closed center () position position () (R)(P)(R) position exhaust center () () (R) (P)(R) position pressure center () () (R)(P)(R) Number of positions () () (R) (P)(R) position double check () () (R) (P) (R) -6-FG-S- -6-FG-S-R -6-FG-D- -6-FG-D-R -6-FHG-D- -6-FHG-D-R -6-FJG-D- -6-FJG-D-R -6-FPG-D- -6-FPG-D-R -6-FIG-D- -6-FIG-D-R Standard Specifications Valve specifications Solenoid specifications Port size / Valve construction Fluid Maximum operating pressure Min. operating pressure mbient and fluid temperature Lubrication Manual override Shock/Vibration resistance Enclosure Coil rated voltage llowable voltage fluctuation Coil insulation type Power consumption (Current) Flow characteristics / (P /) / / (/ E/E) Response C C [dm b /(s bar)] Cv [dm b /(s bar)] Single Double position VDC VDC 00 VC 0 VC 00 VC 0 VC Metal seal 0. MPa 0. MPa 0. MPa ir/inert gas.0 MPa time (ms) 0 or less or less or less or less 0 or less or less 0 or less or less 0 or less 0 or less 0 or less or less Rubber seal 0.0 MPa 0. MPa 0.0 MPa 0 to 60 C () to 60 C () () () Weight (kg) Note ) ased on JIS (Value for supply pressure of 0. MPa, with light/surge voltage suppressor, when using clean air.) Response time values will change depending on pressure and air quality. Value when ON for double type. Note ) Weight without sub-plate. (Sub-plate: 0.7 kg) Not required Push type (Tool required) 0/0 m/s () IP6 (Dusttight, Low jetproof) VDC, VDC, 00 VC, 0 VC, 00 VC, 0 VC (0/60 Hz) ±0% of rated voltage Class or equivalent W DC ( m) W DC (8 m) Inrush. V ( m), Holding. V ( m) Inrush. V (.7 m), Holding. V (.7 m) Inrush. V ( m), Holding. V ( m) Inrush.6 V (.7 m), Holding.6 V (.7 m) Note ) Use dry air to prevent condensation when operating at low temperatures. Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Cv VP S S VS N -0-7

267 Series -6 8 DIN Terminal Type position single : -6-FG-S single (Reverse pressure): -6-YZ-S Manual override ( port) ( port) R P. R -ø6. Mounting hole -/8 (R, R) Indicator light G/ (Cable ø8 to ø0) R. P R. -ø6. Mounting hole -/8 -/, /8 (P,, ) ottom ported drawing (X port) position double : -6-FG-D double (Reverse pressure): -6-YZ-D Manual override G/ (Cable ø8 to ø0) 9 7 (X port) /8 X (PE) port (, port) 9 -/, /8 /8 /, /8 -/8 /8, port X (PE) port P port R, R port Y(PE) port ( port) ( port) R. P R. /, /8 P Port Indicator light -ø6. Mounting hole -/8 R, R port SMC Y position closed center : -6-FHG-D exhaust center : -6-FJG-D pressure center: -6-FIG-D Manual override G/ (Cable ø8 to ø0) (X port) ( port) ( port) R. P. /8 /, /8 -/8 X(PE) port P port R Indicator light -ø6. Mounting hole -0-8

268 ISO Standard Solenoid Valve: Size Metal Seal/Rubber Seal Series -6 9 Prewired Connector Type position single : -6-FG-SSC single (Reverse pressure): -6-YZ-SSC Manual override Cable with connector (L 00) Indicator light (X port) ( port) ( port) position double : -6-FG-D-SC double (Reverse pressure): -6-YZ-D-SC Manual override Cable with connector (L 00) Indicator light (X port) R P R -ø6. Mounting hole (, port) 9 -/, /8 /8 /, /8 -/8 /8, port X(PE) port R, R port P port Y(PE) port /8 X(PE) port ( port) ( port) R. P R. /, /8 P port ø6. Mounting hole 7 9 -/8 R, R port SMC Y R. 0 6 position closed center : -6-FHG-D-SC exhaust center : -6-FJG-D-SC pressure center: -6-FIG-D-SC Manual override Cable with connector (L 00) Indicator light (X port) P R 9 -ø6. Mounting hole -/8 -/, /8 ottom ported drawing (P,, ) X(PE) port ( port) ( port) /8 R. P R. /, /8 P Port -/8 (R, R) 7 -/8 R, R port ø6. Mounting hole 9 VP S S VS N -0-9

269 0 Series -6 Construction DIN Terminal Type Metal seal type -6-FG-S- o -6-FG-D- o Rubber seal type -6-FG-S-R o -6-FG-D-R o -6- FJG -D- -6- FJG FIG -D-R FIG o o w y e q -6-FPG-D- o Replacement Parts (For valve) No. q w e r t y u i o t r u w y e q t r u w y e q FHG t r u t r u w y e q i FHG Description -6-FG-S- -6-FG-D- -6- FJG-D- -6-FPG-D- -6-FG-S-R -6-FG-D-R -6- FJG-D-R FIG FIG Gasket XT00- Gasket Gasket Gasket C O-ring 7 x.6 Mini Y seal MYN- MYN-6 Pilot valve assembly VQZ0Q- Double check spacer VV7-FPG DIN terminal UKL-S FHG t r u w y e q t r u w y e q t r u w y e q FHG -0-0

270 Series -6 Manifold Specifications 0R 0R 0L 0L 0Y 0Y C6R C8R C0R C6L C8L C0L VV7 6 station 0 0 stations (), () port connection Rc / (Right side) Rc /8 (Right side) Rc / (Left side) Rc /8 (Left side) Rc / (ottom side) Rc /8 (ottom side) One-touch fitting ø6 (Right side) One-touch fitting ø8 (Right side) One-touch fitting ø0 (Right side) One-touch fitting ø6 (Left side) One-touch fitting ø8 (Left side) One-touch fitting ø0 (Left side) Mixed Manifold Specifications Manifold block size ISO size Note) When equipped with control unit, or stations are used for mounting. pplicable solenoid valve Series -6 ISO size 0R Note) When ports are mixed, indicate piping specifications by means of the manifold specification sheet. Thread type Nil Rc F G T NPTF Note) It is not applicable to One-touch fittings. Porting specifications (), () port Port location Port size Right, Left ottom / /8 C6 (ø6) C8 (ø8) C0 (ø0) / /8 How to Order Manifold (P), (R) (R) port size / /8 C (ø) Note) When equipped with control unit, or stations are used for mounting. 0D Silencer box Nil S None With (P), (R), (R) port connection 0D 0U 0 0D 0U 0 CD CU C Rc / (ottom side) Rc / (Top side) Rc / (oth sides) Rc /8 (ottom side) Rc /8 (Top side) Rc /8 (oth sides) One-touch fitting ø (ottom side) One-touch fitting ø (Top side) One-touch fitting ø (oth sides) Mixed ir release valve coil rating Control unit type (See pages -0-8 and 9 for details.) Control equipment ir filter with auto-drain ir filter with manual drain Regulator ir release valve Pressure switch lanking plate (ir release valve) lanking plate (Filter, Regulator) lanking plate (Pressure switch) Number of manifold blocks required for mounting (stations) Note) Max. 0 stations Note) When ports are mixed, indicate piping specifications by means of the manifold specification sheet. Weight (kg) 0.n (n: ) Note) The silencer box mounting position corresponds to piping connection at ports (R) and (R). Nil 9 Nil P M MP F G C E None 00 VC, 0/60 Hz 00 VC, 0/60 Hz VDC VDC Other Thread type Nil Rc F G T NPTF Note) It is not applicable to One-touch fittings. VP S S VS N -0-

271 Series -6 DIN Terminal Type VV n-/, / U side U side Manual override R. P =. 9 9 R. L L L L Indicator light P SMC SMC SMC P P 9 0 P =. -/8 (Pilot pressure EXH port) L Dimension L L 07 9 L side 0 6 D side (Single) (Double) ( position) P 9 0 R P MC R 79 9 P R 6 R side /8 (P, R port) SMC (n-/8) P P n: Formula L = n + 6 L = n n-/, /8 (, port) R side L side D side (Single) (Double) ( position) ottom ported drawing -0-

272 ISO Standard Solenoid Valve: Size Metal Seal/Rubber Seal Series -6 Prewired Connector Type VV U side 9 Indicator light Manual override R. SMC SMC P P 9 0 P =. L Dimension L L /8 (Pilot pressure EXH port) L side (Single) (Double) ( position) P R P SMC D side R 9 6 P R R side 6-/8 (P, R port) L L 9 n: Formula L = n + 6 L = n SMC SMC (n-/8) n-/, /8 (, port) P P P VP S S VS N -0-

273 Series -6 Manifold Option Parts lanking plate assembly XT0-9 lock disk (For SUP/EXH passages) XT0- It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. When two or more different high pressures are supplied to one manifold, block disks are installed between stations having different pressures. lso, in cases such as when valve exhaust effects other stations in a circuit, block disks are used for exhaust at stations where the exhaust is to be separated. SUP passage blocked EXH passage blocked SUP passage EXH blocked Individual SUP spacer 0 VV7-P- 0 C0 Individual EXH spacer 0 VV7-R- 0 C Thread type Nil Rc F G T NPTF y mounting individual SUP spacers on a manifold block, it is possible to provide individual supply ports for each valve. Thread type Nil Rc F G T NPTF y mounting individual EXH spacers on a manifold block, exhaust ports can be provided individually for each valve. (, common EXH type) ' ' Note) It is not applicable to One-touch fittings. Note) It is not applicable to One-touch fittings. lock disk (For pilot EXH passage) Z0- When a valve s pilot valve exhaust effects other valves in a circuit, block disks are used between stations where the pilot exhaust passages are to be separated. Throttle valve spacer XT0- throttle valve spacer is mounted on a manifold block to control cylinder speed by throttling exhaust air flow. -0-

274 ISO Standard Solenoid Valve: Size Metal Seal/Rubber Seal Series -6 Reverse pressure spacer XT0-- Residual pressure release valve spacer VV7-R- Thread type Nil Rc F G T NPTF With reverse pressure control manifold specifications, when pressure is changed individually on one side (ex. high speed cylinder return), pressure can be supplied individually to the R side by mounting a reverse pressure spacer. {Port (R) is individual and (R) is common.} This is used by mounting on a manifold block in order to exhaust the residual pressure trapped inside of a cylinder, etc., during an intermediate stop with a position closed center or perfect type valve. Residual pressure at ports and is exhausted individually to the outside by manual operation. R, R individual EXH spacer VV7-R-0 Thread type Nil Rc F G T NPTF y mounting an individual EXH spacer on a manifold block, individual exhaust is possible from both R and R. { (R) and (R) are individual ports.} Main EXH back pressure check plate XT0-7 In cases where back pressure effects actuator operation due to simultaneous operation of manifold valves, etc., this effect can be eliminated by installing a plate between the manifold block and the valve from which back pressure is to be prevented. ' ' ' Individual SUP spacer with residual pressure release valve 0 VV7-PR- 0 Thread type Nil Rc F G T NPTF dapter plate for locked-up cylinder XT0-6 ' This is used by mounting on a manifold block in order to stop the inlet side supply pressure in an individual supply spacer, while at the same time exhausting the residual pressure are performed by pressing the manual override, which can be locked by turning it. When using a locked-up cylinder with valves for control, this spacer can be used by mounting on a manifold block. It consists of a circuit equipped with a function to prevent lurching during release. ' VP S S VS N -0-

275 Series -6 6 Manifold Option Parts Silencer box VV7---S Pilot EXH silencer N0-0 This can be provided as a unit on the end plate to reduce manifold exhaust noise and piping labor. This is used by mounting on the pilot exhaust port in order to reduce manifold and single type pilot exhaust noise, and to prevent the entry of dust. Release valve spacer XT0-7 Thread type Nil Rc F G T NPTF ' -0-6

276 ISO Standard Solenoid Valve: Size Metal Seal/Rubber Seal Series -6 7 Double check spacer VV7-FPG Double check spacer with residual pressure release valve VV7-FPGR y combining a position exhaust center valve with a double check spacer, an intermediate stopping position of a cylinder can be held for an extended period. It can also be used for drop prevention at the cylinder stroke end when releasing residual supply pressure, by combining it with a position single or double valve. Specifications Double check spacer part no. pplicable solenoid or air operated valve One solenoid energized (One pilot pressurized) Leakage (cm /min (NR)) Interface regulator P R0-00- Caution Spacer Interface regulators can be placed on top of the manifold block to reduce the pressure of each of the valves. Part No. P reduced pressure reduced pressure reduced pressure oth solenoids unenergized (oth pilots unpressurized) R0-00-P R0-00- R0-00- P P R R R R R R Caution VV7-FPG Series Regulating port This is a double check spacer equipped with a residual pressure release function, to release residual pressure inside a cylinder during maintenance or adjustment, etc. Regulating port Since extended cylinder stops are not possible if there are leaks from piping between the valve and cylinder or from fittings, etc., check for leakage using a neutral liquid detergent. Since One-touch fittings allow slight air leakage, screw piping (with M thread) is recommended when stopping the cylinder in the middle for a long time. This spacer cannot be combined with a position closed center valve. Set the load weight so that the cylinder side pressure is less than two times the supply side pressure. When using the residual pressure release function, confirm the action of actuators, etc., and operate after providing for safety measures. Regulating port P When combining a pressure center valve and interface regulator with reduced pressure at ports and, use model R0-. When combining a reverse pressure valve and interface regulator, use model R0-. Further, it cannot be used with reduced pressure at port P. When combining a double check valve and an interface regulator, use a manifold or sub-plate as a basis, and stack them in the following order; the perfect spacer the interface regulator the valve. When a closed center valve is combined with the interface regulator s, port regulation, note that it cannot be used for intermediate stops of a cylinder because there is leakage from relief port on the regulator VP S S VS N

277 Series -6 8 Control Unit Control equipment (filters, regulators, pressure switches, air release valves) has been made into standardized units which can be mounted on manifolds without any modifications. Control Unit Specifications ir filter (With auto-drain/with manual drain) Filtration degree µm Regulator Set pressure (Outlet pressure) 0.0 to 0.8 MPa Pressure switch Pressure adjustment range 0. to 0.7 MPa Contact ab Rated current (Induction load) VC, 0 VC ir release valve (Single only) Operating pressure range 0. to.0 MPa Manifold specifications example XT FHG-D -6-FG-D -6-FG-S ir release valve X Pressure switch ir filter regulator Po P" P' Control unit Option lanking plate Release valve adapter plate Control equipment Pressure switch Control Unit Type Ordering symbol Control equipment ir filter with auto-drain ir filter with manual drain Regulator ir release valve Pressure switch lanking plate (ir release valve) lanking plate (Filter, Regulator) lanking plate (Pressure switch) Number of manifold blocks required for mounting (stations) Use of Control Unit Caution XT0-9 (For manifold) XT0-8 (For release valve adapter plate) MP (For control equipment/filter regulator) MP (For pressure switch) XT0-7 VW- (dapter plate, Filter with auto-drain cock, Regulator) VW-M (dapter plate, Filter with manual drain cock, Regulator) IS00-X0 Nil stations P stations M MP F G C E stations stations stations stations stations station <Construction and piping >. The supply pressure (Po) passes through the regulator with filter and is adjusted to the prescribed pressure. Next, it goes through the release valve (downstream residual pressure switching function used as normally ON) and is supplied to the manifold base side (P).. When the release valve w is OFF, the supply pressure from port Po is blocked, and the air which was being supplied to the manifold side port P passes through the release valve and is discharged from port R.. The pressure switch is piped into the outlet side of the release valve w. (It operates when the release valve w is energized.) lso, since there is an internal voltage drop of V, it may not be possible to confirm the OFF and ON states with a tester, etc. In the case of air filters with auto-drain or manual drain, mount so that the air filter is at the bottom. -0-8

278 ISO Standard Solenoid Valve: Size Metal Seal/Rubber Seal Series -6 9 Manifold with control unit L Dimension L L /8 0 6 Manual override 9 0 /8 Supply port (Pilot pressure EXH port) L side Control unit D side ( position) (Double) 0. (Single) P R ø. P SMC U side R. R P P 9 6 R R side Indicator light Release valve SMC Pressure switch 9 6 -/8 (R, R port) 8 8 n: Formula L = n + 6 L = n + 76 SMC n-/8 SMC SMC SMC Drain port P: / P P P P P n-/, /8 (, port) 0 P =. L L (. for MP) L VP S S VS N L L = n + (.) (8.) (0.) (.) (87.) (0.) (7.) (6.) (9.) (60.) (6.) L dimensions inside ( ) are for MP. -0-9

279 Series -6 0 Manifold Option Parts Residual pressure release valve spacer Z0-8 Interface regulator P R0-00- Interface regulator P R SMC SMC P 6 (7) 0 (77) 9. (6.) 0. (77.) Dimensions inside ( ) are for sub-plate. Throttle valve spacer XT0- Throttle valve spacer (XT0-) R E S L O W SMC P 9 (6) 6 (7) 9. (6.) 79. (.) Dimensions inside ( ) are for sub-plate. P P R P SMC R R P P R P SMC R R Manual override Residual pressure release valve spacer (Z0-8 ) Silencer box XT0-60 SMC P E R P 6 9 (67) 6 (7) (67.) 8. (.) Dimensions inside ( ) are for sub-plate. P P P R P SMC R R P R P SMC R R -0-0

280 ISO Standard Solenoid Valve: Size Metal Seal/Rubber Seal Series -6 Individual SUP spacer VV7-P- Individual EXH spacer VV7-R- R, R individual EXH spacer VV7-R-0 Reverse pressure spacer XT0-- Double check spacer Double check spacer with residual pressure release valve VV7-FPG VV7-FPGR SMC n-/, /8 Main EXH back pressure check plate XT0-7 Main EXH back pressure check plate (TX0-7) SMC P P Individual SUP spacer: VV7-P- -/, /8, C0 Individual EXH spacer: VV7-R- -/, /8, C R, R individual EXH spacer: VV7-R-0 -/8 Reverse pressure spacer XT0-- Rc /8 (Right side only) P P R R R P P SMC SMC R R P P R Double check spacer (VV7-FPG) Double check spacer with residual pressure release valve (VV7-FPGR) Residual pressure release valve spacer SMC P 6 (7) 0 (77) 9. (6.) 0. (77.) Dimensions inside ( ) are for sub-plate. Individual SUP spacer with residual pressure release valve SMC P 6 (7) 9 (67) 9. (67.) 8. (.) Residual pressure exhaust valve spacer (VV7-R-) Individual SUP spacer with residual pressure release valve (VV7-PR-) Dimensions inside ( ) are for sub-plate. P R R P SMC R P VV7-R- VV7-PR- P P R R P SMC R VP S S VS N -0-

281 ISO Standard Solenoid Valve: Size Metal Seal/Rubber Seal, Single Unit Series -8 For details about certified products conforming to international standards, visit us at How to Order Valves 8 FG S FG YZ FHG FJG FPG Passage symbol ()() (R)(P)(R) ()() (R)(P)(R) ()() (R)(P)(R) ()() (R)(P)(R) ()() (R)(P)(R) ()() FIG (R)(P)(R) Option Number of solenoids 9 S D Single Double VS Port size Side ported Rc /8 Side ported Rc / Side ported Rc / ottom ported Rc /8 ottom ported Rc / ottom ported Rc / Option Nil Z V Coil rated Seal Nil R Connector Nil O SC Sub-plate port size Nil Without sub-plate Side ported Rc /8 Side ported Rc / Side ported Rc / ottom ported Rc /8 ottom ported Rc / ottom ported Rc / Metal seal Rubber seal None Light/Surge voltage suppressor Individual pilot exhaust When two or more symbols are specified, indicate them alphabetically. 00 VC 00 VC VDC VDC Other voltages For other voltages, please contact SMC separately. How to Order Sub-plate Thread type Nil F T Rc G NPTF Specifications Model VS7--0 VS7--0 VS7--06 VS7--0 VS7--0 VS7--06 Porting specifications Piping location Side ottom DIN terminal block (With connector) DIN terminal block (Without connector) Pre-wired connector Port size /8 / / /8 / / Thread type Nil F T Weight (kg) Rc G NPTF -0-

282 ISO Standard Solenoid Valve: Size Metal Seal/Rubber Seal Series -8 Model Series -8 position position Number of positions Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Model JIS position single position double (Metal) ()() (R)(P)(R) position double (Rubber) position closed center ()() ()() (R)(P)(R) position exhaust center ()() (R)(P)(R) position pressure center ()() (R)(P)(R) Single Double Closed center Exhaust center Double check Pressure center ()() (R)(P)(R) (R)(P)(R) position double check ()() (R)(P)(R) -8-FG-S- -8-FG-S-R -8-FG-D- -8-FG-D-R -8-FHG-D- -8-FHG-D-R -8-FJG-D- -8-FJG-D-R -8-FPG-D- -8-FPG-D-R -8-FIG-D- -8-FIG-D-R Port size / Standard Specifications Valve construction Fluid Maximum operating pressure Min. operating pressure mbient and fluid temperature Lubrication Manual override Shock/Vibration resistance Enclosure Coil rated voltage llowable voltage fluctuation Coil insulation type Power consumption (Current) Flow characteristics / (P /) / / (/ E/E) C[dm /(s bar)] b Cv C[dm/(s bar)] b Cv Single Double position VDC VDC 00 VC 0 VC 00 VC 0 VC Metal seal 0. MPa 0. MPa 0. MPa ir/inert gas.0 MPa () () Response Weight time (kg) (ms) 0 or less 0.6 or less or less or less or less or less or less or less 60 or less or less or less or less Note ) ased on JIS (Value for supply pressure of 0. MPa, with light/surge voltage suppressor, when using clean air.) Response time values will change depending on pressure and air quality. Value when ON for double type. Note ) Weight without sub-plate. (Sub-plate: Rc.8, /: 0.68 kg, Rc /:.9 kg) Valve specifications Solenoid specifications Rubber seal 0.0 MPa 0. MPa 0.0 MPa 0 to 60 C () to 60 C () Not required Push type (Tool required) 0/0 m/s () IP6 (Dusttight, Low jetproof) VDC, VDC, 00 VC, 0 VC, 00 VC, 0 VC (0/60 Hz) ±0% of rated voltage Class or equivalent W DC ( m) W DC (8 m) Inrush. V ( m), Holding. V ( m) Inrush. V (.7 m), Holding. V (.7 m) Inrush. V ( m), Holding. V ( m) Inrush.6 V (.7 m), Holding.6 V (.7 m) Note ) Use dry air to prevent condensation when operating at low temperatures. Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) VP S S VS N -0-

283 P P P Series -8 DIN Terminal Type position single : -8-FG-S single (Reverse pressure): -8-YZ-S Manual override Indicator light G/ (Cable ø8 to ø0) (7) 6(7) 6(0)( port) 6(0)( port) R P R 9(6) 9(6) P 0 6(7) 7(86) -ø7. Mounting hole 8. 9(6) 9(6) () () R P R (0)8 8 (0) (8) (8) -ø7. Mounting hole ()0 (6) ()6 6 () 6(7) 7(86) -/8 -/8, /, / (P,,, R, R) ottom ported drawing position double : -8-FG-D double (Reverse pressure): -8-YZ-D Manual override (66) () 7(86) 6(7) (.) 0(6) 8() ( ): / (66) () (0) () 08.(.) 0(6) 8() G/ (Cable ø8 to ø0) -0- /8 X(PE) port () (0) /8 X(PE) port (7) 6(7) 6(0)( port) 6(0)( port) R 9(6) 9(6) P 0() 0() R 0() 0() P Indicator light -ø6. Mounting hole -/8, /, / R, R port /8, /, / P port -/8, /, / R, R port /8, /, / P port SMC Y 0 () (0) (, port) 8() /8 Y(PE) port -/8, /, /, port position closed center : -8-FHG-D exhaust center : -8-FJG-D pressure center: -8-FIG-D Manual override 7(86) 6(7) G/ (Cable ø8 to ø0) (66) () 08.(.) 0 8 0(6) 8() () (0) /8 X(PE) port (7) 6(7) 6(0)( port) 6(0)( port) R P 9(6) 9(6) 0() 0() R P ( ): / Indicator light -ø6. Mounting hole -/8, /, / R, R port /8, /, / P port ( ): / Dimensions inside are for rubber seals.

284 P P P ISO Standard Solenoid Valve: Size Metal Seal/Rubber Seal Series -8 Prewired Connector Type position single : -8-FG-S-SC single (Reverse pressure): -8-YZ-S-SC Manual override Cable with connector (L 00) Indicator light 8() /8 X(PE) port (7) 6(7) 6(0)( port) 6(0)( port) 9(6) 9(6) 0() 0() 0 6(7) 7(86) (0) () 0(6) position single : -8-FG-D-SC single (Reverse pressure): -8-YZ-D-SC Manual override Cable with connector (L 00) Indicator light 8() /8 X(PE) port R P R P (7) 6(7) 6(0)( port) 6(0)( port) R P 9(6) 9(6) 0() 0() R P -ø7. Mounting hole -/8, /, / R, R port /8, /, / P port 8 0 -ø7. Mounting hole 6(7) 7(86) (0) () 0(6) -/8, /, / R, R port /8, /, / P port ( ): / 08.(.) 08.(.) SMC Y 0 () 8. 9(6) 9(6) () () R (0) 8 8 (0) (8) (8) (0) (, port) 8() () 0 (6) () 6 6 () 6(7) 7(86) position closed center : -8-FHG-D-SC exhaust center : -8-FJG-D-SC pressure center: -8-FIG-D-SC Manual override Cable with connector (L 00) Indicator light 8() /8 X(PE) port P R ottom ported drawing /8 Y(PE) port -/8, /, /, port (7) 6(7) 6(0)( port) 6(0)( port) R P R 9 (6) 9(6) P 0() 0() -ø7. Mounting hole -/8 -/8, /, / (P,,, R, R) ( ): / 8 0 -ø7. Mounting hole -/8, /, / R, R port /8, /, / P port ( ): / Dimensions inside are for rubber seals. 6(7) 7(86) (0) () 0(6) 08.(.) VP S S VS N -0-

285 6 Series -8 Construction DIN Terminal Type Metal seal -8-FG-S-!0 Rubber seal type -8-FG-S-R!0-8-FG-D-! FPG-D-!0 Replacement Parts (For valve) Number q w e r t y u i o!0-0-6 t r i w y e q t r i w y e q FHG FJG FIG!0 t r i w y e q t r i w y e q o -D- u -8-FG-D-R -8- -D-R Description -8-FG-S- -8-FG-D- -8--D- -8-FPG-D- -8-FG-S-R -8-FG-D-R -8--D-R Gasket Gasket Gasket Gasket C O-ring Mini Y seal Mini Y seal Pilot valve assembly Double check spacer DIN terminal FHG FJG FIG t r i w e XT x.6 MYN-6 MYN- MYN-8 VQZ0Q- VV7-FPG UKL-S q!0 t r i w e q!0 t r i w e q : FHG, FJG, FIG

286 7 Series -8 Manifold Specifications How to Order Manifold VV7 6 0R 0D station 0 0 stations (), () port connection 0R 0R 0L 0L 0Y 0Y Rc / (Right side) Rc / (Right side) Rc / (Left side) Rc / (Left side) Rc / (ottom side) Rc / (ottom side) Mixed Manifold Specifications Manifold block size ISO size Note) When ports are mixed, indicate piping specifications by means of the manifold specification sheet. pplicable solenoid valve Series -8 ISO size Porting specifications (), () port size /8 / Thread type Nil F T Rc G NPTF (P), (R) (R) port size / / ir release valve Nil E Max. 0 stations (P), (R), (R) port connection 0D 0U 0 06D 06U 06 None With air release valve Weight (kg) 0.96n (n: ) Thread type Nil Rc F G T NPTF Rc / (ottom side) Rc / (Top side) Rc / (oth sides) Rc / (ottom side) Rc / (Top side) Rc / (oth sides) Silencer box Nil S ir release valve coil rating Nil 9 None With None 00 VC, 0/60 Hz 00 VC, 0/60 Hz VDC VDC Other Note) The mounting position of the silencer box corresponds to (R) and (R) port connections. VP S S VS N -0-7

287 P P P P P Series -8 8 DIN Terminal Type VV7-- Manual override 8 U side R. 9 Indicator light 8 -/8 P, R, R port for Rc / only SMC P = 6 60(7) 60(7) P = 6 n-/8, / 9 R. 8 U side L side -/8 (Pilot pressure EXH port) 6-/, / L Dimension P, R, R port / / L n L L L L 6 8. (Single) 7. (Double) ( position) R P P P () () SMC D side R R side L L 8(7) 67 0(.) SMC SMC SMC (n-/8) Formula 6 n: L = 6n L = 6n n: L = 6n L = 6n + 06 ( ): / Dimensions inside are for rubber seals. 0() L L n-/8, / R side 8. ottom ported drawing D side (Single) 7. (Double) ( position) L side -0-8

288 P P P P P ISO Standard Solenoid Valve: Size Metal Seal/Rubber Seal Series -8 9 Pre-wired Connector Type VV7-- Indicator light Manual override 8 U side R /8 P, R, R port for Rc / SMC P = 6 60 (7) L Dimension P, R, R port / / L n L L L L L side -/8 (Pilot pressure EXH port) 6-/, / R P P P () () SMC D side (Single) 7. (Double) ( position) R R side L L 8(7) 0(.) Formula n: L = 6n + 6 L = 6n + 80 n: L = 6n + 90 L = 6n + 06 ( ): / Dimensions inside are for rubber seals. SMC SMC SMC (n-/8) () n-/8, / VP S S VS N -0-9

289 Series -8 0 Manifold Option Parts lanking plate assembly XT-9 It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. lock disk (For SUP/EXH passages) XT-- (For SUP) XT-- (For EXH) When two or more different high pressures are supplied to one manifold, blocking plates are installed between stations having different pressures. lso, in cases such as when valve exhaust effects other stations in a circuit, block disks are used for exhaust at stations where the exhaust is to be separated. Individual SUP spacer 0 VV7-P Thread type Nil F T Rc G NPTF y mounting individual SUP spacers on a manifold block, it is possible to provide individual supply ports for each valve. Individual EXH spacer VV7-R- Thread type Nil F T Rc G NPTF y mounting individual EXH spacers on a manifold block, exhaust ports can be provided individually for each valve. (, common exhaust type) ' ' lock disk (For pilot EXH passage) Z-9 Throttle valve spacer XT0- SUP passage blocked EXH passage blocked When a valve s pilot valve exhaust effects other valves in a circuit, block disks are used between stations where the pilot exhaust passages are to be separated. throttle valve spacer is mounted on a manifold block to control cylinder speed by throttling exhaust air flow. SUP passage EXH blocked -0-0

290 ISO Standard Solenoid Valve: Size Metal Seal/Rubber Seal Series -8 Reverse pressure spacer XT9-9- Thread type Nil F Rc G Main EXH back pressure check plate XT- With reverse pressure control manifold specifications, when pressure is changed individually on one side (ex. high speed cylinder return), pressure can be supplied individually to the R side by mounting a reverse pressure spacer. {Port (R) is individual and (R) is common.} T Port size /8 / NPTF In cases where back pressure effects actuator operation due to simultaneous operation of manifold valves, etc., this effect can be eliminated by installing a plate between the manifold block and the valve from which back pressure is to be prevented. R/R individual EXH spacer VV7-R-0 Thread type Nil F T Rc G NPTF y mounting an individual EXH spacer on a manifold block, individual exhaust is possible from both R and R. { (R) and (R) are individual ports.} Conversion adapter plate VV7-V- This conversion adapter plate allows a -6 (size ) valve to be mounted on a -8 manifold base. (V type) ' ' ' dapter plate for locked-up cylinder XT60-6 When using a locked-up cylinder with valves for control, this spacer can be used by mounting on a manifold block. It consists of a circuit equipped with a function to prevent lurching during release. VP S S VS N -0-

291 Series -8 Manifold Option Parts Double check spacer VV7-FPG y combining a position exhaust center valve with a double check spacer, an intermediate stopping position of a cylinder can be held for an extended period. It can also be used for drop prevention at the cylinder stroke end when releasing residual supply pressure, by combining it with a position single or double valve. Silencer box VV7---S This can be provided as a unit on the end plate to reduce manifold exhaust noise and piping labor. Specifications Double check spacer part no. pplicable solenoid or air operated valve Leakage (cm /min (NR)) Interface regulator R0-00- P One solenoid energized (One pilot pressurized) oth solenoids unenergized (oth pilots unpressurized) P P VV7-FPG Series VS7-8/VS7-8 R R R R R R Spacer Interface regulators can be placed on top of the manifold block to reduce the pressure of each of the valves. Part No. P reduced pressure reduced pressure reduced pressure R0-00-P R0-00- R0-00- Caution Regulating port Regulating port Regulating port P When combining a pressure center valve and interface regulator with reduced pressure at ports and, use model R0-. When combining a reverse pressure valve and interface regulator, use model R0-. Further, it cannot be used with reduced pressure at port P. When combining a double check valve and an interface regulator, use a manifold or sub-plate as a basis, and stack them in the following order; the perfect spacer the interface regulator the valve. When a closed center valve is combined with the interface regulator s, port regulation, note that it cannot be used for intermediate stops of a cylinder because there is leakage from relief port on the regulator. -0-

292 SMC SMC SMC SMC ISO Standard Solenoid Valve: Size Metal Seal/Rubber Seal Series -8 Manifold Option Parts Interface regulator R0-00- P Main EXH back pressure check plate XT- Interface regulator R0-00- P 8 6 Main EXH back pressure check plate (XT-) 80. (0) 6. (0) 8 6. (96) (08) Throttle valve spacer XT0- RIE S L O W P Dimensions inside ( ) are for sub-plate aperture Rc /8 and /. Dimensions inside are for sub-plate aperture Rc /. Throttle valve spacer (XT0-) P 80.(0) 6 9.(89) 0 0.(80) 9.(9) 0 Dimensions inside ( ) are for sub-plate aperture Rc /8 and /. Dimensions inside are for sub-plate aperture Rc /. R PE R PE E E P P E PE R E PE R Double check spacer VV7-FPG Double check spacer VV7-FPG P P (0) 6 0(09.) (00.). Dimensions inside ( ) are for sub-plate aperture Rc /8 and /. Dimensions inside are for sub-plate aperture Rc /. (.). R PE R PE E E P P E E PE PE R R VP S S VS N -0-

293 Series -8 Manifold Option Parts Individual EXH spacer VV7-R-0/0 Individual SUP spacer VV7-P-0/0 R/R individual EXH spacer VV7-R-0 Reverse pressure spacer XT-9- Silencer box XT-6 SMC SMC P R PE P PE R P PE PE P PE Residual pressure release valve spacer Z-9 Manual override Individual EXH spacer VV7-R- -/8, / Individual SUP spacer: VV7-P- -/8, / R, R individual EXH spacer: VV7-R-0 -/ Reverse pressure spacer: X-9- -/8, / SMC P 80.(0) 6 0.(90) 0.(8) 9.(9) 06 Residual pressure release valve spacer (Z-9 ) Dimensions inside ( ) are for sub-plate aperture Rc /8 and /. Dimensions inside are for sub-plate aperture Rc /. E R PE E P E E PE R 78 R E E R -0-

294 SMC SMC SMC SMC SMC SMC SMC SMC SMC SMC SMC SMC SMC SMC SMC SMC ISO Standard Solenoid Valve: Size Metal Seal/Rubber Seal Series -8 Manifold Option Parts/Mounting olt Part No. -6 Mounting olt Part No. Number of options Mounting bolt No. Size 0 Single stack Double stack XT6-- XT6-- XT6-- XT6-- XT6--6 XT6--7 XT6--8 XT6--9 XT6--0 XT6-- XT6-- XT6-- M x with SW M x with SW M x with SW M x 60 with SW M x 6 with SW M x 70 with SW M x 7 with SW M x 90 with SW M x 9 with SW M x 00 with SW M x 0 with SW M x with SW Option mounting diagram Number of options Mounting bolt Option mounting diagram No. Size Valve Throttle valve spacer Spacer () Spacer () Spacer () Spacer () Throttle valve spacer lanking plate Spacer () Spacer () Throttle valve spacer Interface regulator Throttle valve spacer Spacer () Main exhaust back pressure check plate Spacer () Spacer () Spacer () Double check spacer Spacer () Spacer () Throttle valve spacer Spacer () Spacer () Throttle valve spacer Spacer () Interface regulator Double check spacer Spacer () Spacer () Triple stack XT6-- XT6--6 XT6--7 XT6--8 XT6--9 M x 0 with SW M x 0 with SW M x with SW M x 0 with SW M x with SW Note ) -8 Mounting olt Part No. Number of options Mounting bolt No. Size Spacer () Spacer () Spacer () Note ) Note ) Note ) Interface regulator Release valve spacer Double check spacer Spacer () Spacer () Spacer () Throttle valve spacer Spacer () Interface regulator Spacer () Spacer () Spacer () Double check spacer Spacer () Interface regulator Throttle valve spacer Interface regulator Double check spacer Spacer () Spacer () The installation position of spacer () in the option mounting diagrams is limited only by the precautions given below. Spacers Main EXH back pressure check plate Throttle valve spacer Release valve spacer Spacer () Individual SUP spacer Individual EXH spacer R, R individual EXH spacer Reverse pressure spacer Residual pressure release valve spacer Individual SUP spacer with residual pressure release valve 0 Single stack Double stack XT6-- XT6-- XT6-- XT6-- XT6--6 XT6--7 XT6--8 XT6--9 XT6--0 XT6-- M6 x with SW M6 x 8 with SW M6 x with SW M6 x 8 with SW M6 x 00 with SW M6 x 0 with SW M6 x with SW M6 x 0 with SW M6 x with SW M6 x 60 with SW Valve lanking plate Main exhaust back pressure check plate Number of options Triple stack Mounting No. XT6-- XT6-- XT6-- XT6-- bolt Size M6 x 6 with SW M6 x 80 with SW M6 x 8 with SW M6 x 00 with SW Spacers Main EXH back pressure check plate Interface regulator (P reduced pressure) Interface regulator ( port regulation) Interface regulator ( port regulation) Double check spacer Spacer () Individual SUP spacer Individual EXH spacer R, R individual EXH spacer Reverse pressure spacer Residual pressure release valve spacer Throttle valve spacer Note ) Spacer () Spacer () Note ) Spacer () Interface regulator (P port regulation) Interface regulator ( port regulation) Interface regulator ( port regulation) Double check spacer Double check spacer with residual pressure release valve Note ) throttle valve spacer and double check spacer (including those with residual pressure release valve) cannot be combined. Note ) When a double check spacer (Top) (including those with residual pressure release valve) and individual EXH spacer (ottom) are combined with a R, R individual EXH spacer (ottom), be careful regarding the installation position. Note ) When an interface regulator (Top) and double check spacer (ottom) (including those with residual pressure release valve) (ottom) are combined, be careful regarding the installation position. Option mounting diagram Option mounting diagram Note ) throttle valve spacer and double check spacer cannot be combined. Note ) There is no limitation on the mounting position for spacer (). VP S S VS N -0-

295 Series -8 6 Exploded View of Manifold D side end plate assembly Tension bolt Manifold block assembly U side end plate assembly <End Plate ssembly> XT0 End plate position L R P, R port size 0 0 C U side D side Rc / Rc /8 One-touch fitting for ø <Manifold lock ssembly> XT0 Porting specifications Side ottom Cylinder port size 0 0 () C6 () C8 () C0-0-6 Rc / Rc /8 One-touch fitting for ø6 One-touch fitting for ø8 One-touch fitting for ø0 Note ) Side piping only Note ) In this manifold block assembly, the tension bold for increasing station ( station) is included. Thread type Nil Rc F G T NPTF Note) It is not applicable to One-touch fittings. Cylinder port location L R Thread type Nil Rc F G T NPTF L side R side Note) It is not applicable to One-touch fittings. <Tension olt Part No.> XT0 0 For stations For stations For 0 stations Note) These tie-rods are solid pieces for each number of stations. Replacement Parts (For manifold block) Part no. XT0-9 XT0-0 XT0-- XT0- M x 8 Description O-ring O-ring Plate Gasket Oval countersunk head screw Qty. Material NR NR SPCC NR SWRH

296 ISO Standard Solenoid Valve: Size Metal Seal/Rubber Seal Series -8 7 Exploded View of Manifold D side end plate assembly Manifold block assembly U side end plate assembly <End Plate ssembly> XT End plate position L U side R D side P, R port size 0 06 C Rc / Rc / One-touch fitting for ø Replacement Parts (For manifold block) Part no. XT- S68-0 S68-00 XT- XT- MX0 XT-6- XT-6- Thread type Nil Rc F G T NPTF Note) It is not applicable to One-touch fittings. Description O-ring O-ring O-ring Gasket Plate Oval countersunk head screw Connection fitting Connection fitting Qty. Material NR NR NR NR SPCC SWRH <Manifold lock ssembly> XT Cylinder port size 0 0 Wiring specifications Side ottom /8 / Thread type Nil F T Rc G NPTF Cylinder port location L R L side R side VP S S VS N XT-6- Hexagon socket head screw -0-7

297 Conforming to ISO Standard Solenoid Valve (with M Connector) Series 7-6/7-8/7-0 (Size ) (Size ) (Size ) Lightweight Size ( position): 0. kg Size ( position): 0.80 kg Size ( position):. kg Interface conforms to ISO standard Size (7-6), Size (7-8), and Size (7-0) Conform to ISO99/ ccommodates enclosure IP6 Dust/Splashproof type Large capacity Flow rate 7-6 (Size ) 00 l/min (NR) 7-8 (Size ) 000 l/min (NR) 7-0 (Size ) 00 l/min (NR) Cylinder driving size ø00 ø60 ø00 Rubber seal, single type Reduced installation space Up to 7% reduction in square area installation compared to Series 7 Up to % reduction in cubic area installation for Cnomo Wide variety of manifold option ( ( VP S S VS N --

298 ISO Standard Solenoid Valve Size,, /Single Unit Series 7-6/7-8/7-0 Valve Sub-plate FG FHG FJG FIG FPG 7 6 FG S M0 Size 6 Size 8 Size 0 Size Passage symbol Piping specifications Side-ported / Side-ported /8 Side-ported / Side-ported / Side-ported ottom-ported / ottom-ported /8 ottom-ported / ottom-ported / () () (R) ()() (P)(R) (R)(P)(R) ()() (R)(P)(R) ()() (R)(P)(R) ()() (R)(P)(R) vailable for 7-6 and 7-8 only VS7 Size Size Size Size Size Number of solenoids S Single D Double Rated coil voltage VDC VDC 9 Voltage other than above (0 VDC or less) Nil Z 0 Port size Size Size Thread type Nil Rc F G T NPTF How to Order Option None Light/Surge voltage suppressor Specifications Model VS7--0 VS7--0 VS7--0 VS7--0 VS7--0 VS7--0 VS7--06 VS7--0 VS7--0 VS7--06 VS7--0 VS7--06 VS7--0 VS7--0 VS7--06 Sealing type Nil R Piping direction Horizontal ottom Horizontal ottom Horizontal ottom Metal seal Rubber seal Thread type Nil Rc F G T NPTF Port size Piping specifications Nil Without sub-plate 0 Side-ported / 0 Side-ported /8 0 Side-ported / 06 Side-ported / 0 Side-ported 0 ottom-ported / 0 ottom-ported /8 0 ottom-ported / 06 ottom-ported / Piping specifications Port size for (P), (), () / / / /8 /8 /8 / / /8 / / / / / Size Port size for (R), (R) /8 /8 / / Size Size Weight (kg)

299 Series 7- Manifold Specifications 0R 0R 0L 0L 0Y 0Y C6R C8R C0R C6L C8L C0L Manifold (), () port size / (Right side) /8 (Right side) / (Left side) /8 (Left side) / (ottom) /8 (ottom) ø6 One-touch fitting (Right side) ø8 One-touch fitting (Right side) ø0 One-touch fitting (Right side) ø6 One-touch fitting (Left side) ø8 One-touch fitting (Left side) ø0 One-touch fitting (Left side) Mixed Size Size (), () port size 0R /8 (Right side) 0R / (Right side) 0L /8 (Left side) 0L / (Left side) 0Y /8 (ottom) 0Y / (ottom) Mixed VV7 6 0R 0D VV7 6 0R 0D Size Size station stations Nil E How to Order Thread type Nil Rc F G T NPTF ir release valve None With air release valve (P), (R), (R) port size 0D / (Down side) 0U / (Up side) 0 / (oth sides) 06D / (Down side) 06U / (Up side) 06 / (oth sides) Control unit type (P), (R), (R) port size 0D 0U 0 0D 0U 0 CD CU C Control component ir filter with auto drain ir filter with manual drain Regulator ir release valve Pressure switch lanking plate (ir release valve) lanking plate (Filter, Regulator) No. of stations for mounting Nil / (Down side) / (Up side) / (oth sides) /8 (Down side) /8 (Up side) /8 (oth sides) ø One-touch fitting (Down side) ø One-touch fitting (Up side) ø One-touch fitting (oth sides) Mixed Thread type Nil Rc F G T NPTF P Rated coil voltage for air release valve Nil None VDC VDC Voltage other than above 9 (0 VDC or less) Silencer box Nil None S With silencer box M MP F G C E VP S S VS N --

300 Series 7- Model Series 7-6 position position Positions Single Double Closed center Exhaust center Pressure center Perfect type Series 7-8 position position Series 7-0 position position Positions Single Double Closed center Exhaust center Pressure center Perfect type Positions Single Double Closed center Exhaust center Pressure center Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal ore size / ore size /8 ore size / Flow characteristics, (P, ),, (, E, E) C b Cv C b Cv Flow characteristics, (P, ),, (, E, E) C b Cv C b Cv Flow characteristics, (P, ),, (, E, E) C b Cv C b Cv

301 Conforming to ISO Standard Solenoid Valve (with M Connector) Series 7- JIS position single ()() (R)(P) (R) position double (metal) () () (R)(P) (R) position double (rubber) () () (R)(P)(R) position closed center () () (R)(P) (R) position exhaust center ()() (R)(P)(R) position perfect () () (R)(P) (R) position pressure center ()() (R)(P) (R) Standard Specifications Valve specifications Electric specifications Valve type Fluid Maximum operating pressure Minimum operating pressure Single Double position mbient and fluid temperature Lubrication Manual override Impact resistance/ Vibration resistance Enclosure Rated coil voltage llowable voltage fluctuation Type of coil insulation Power VDC consumption VDC Caution Internal Wiring Specifications port side SOL port side SOL DC: Single ZNR COM ZNR ZNR DC: Double Metal seal 0. MPa 0. MPa 0. MPa 0 to 60 C () port side SOL Rubber seal ir, Inert gas.0 MPa 0. MPa 0. MPa 0. MPa: Size 0. MPa: Size, to 60 C () None Push type (Tool required) 0/0 m/s () IP6 (Dust/Splashproof type) VDC, VDC to +0% of rated voltage Equivalent to Class.8 W DC (7 m).8 W DC (0 m) Note ) Use dry air to prevent condensation at low temperatures. Note ) Impact resistance: No malfunction resulted during on the impact test using a drop impact tester. The test was performed one time each in the axial and right angle directions of the main valve and armature for both energized and de-energized conditions. Vibration resistance: No malfunction resulted during a one-sweep test between 8. and 000 Hz. The test was performed in the axial and right angle directions of the main valve and armature for both energized and deenergized conditions. Precautions M connector: Wiring specifications Pin no. : Open : port side SOL (+) : COM (-) : port side SOL (+) : Ground VP S S VS N --

302 Series 7-6 Dimensions 7-6-FG-S-M ( port) ( port) ø6. mounting hole /8- port, port 7-6-FG-D-M0 Manual override PE port Manual override PE port Indicator light Iindicator light ( port) ( port) /8 port 89 /8 port ( port) ( port) R R. P R.. M connector P /, /8 port. M connector R /, /8 port ø6. mounting hole /8- port, port -ø6. mounting hole PE port 7 9 /8- port, port 7. /8 port 9 H 7-6-F JI G-D-M0 Manual override PE port Indicator light ( port) (, port) 89 /8 port ( port) ( port) R /, /8- port, port Y ottom ported P.. M connector R /, /8 port /8- port, port /, /8- port,, port -ø6. mounting hole /8- port, port PE port

303 Conforming to ISO Standard Solenoid Valve (with M Connector) Series 7-7 Dimensions 7-6-FPG-D-M ( port) ( port) VV7-- (M Connector type) Manual override L-side -/8, port R U-side P P R R M connector R R 9 D-side 89 (Single) 86 (Double) 96 ( position) Manual override R-side Indicator light PE port L L 9 ( port) 6-/8,, port Indicator light 6 /8 port. R. P (n /8). R M connector /, /8 port P P P P P L n L L 77. -ø6. mounting hole /8- port, port PE port 7. P = n-/, /8, port 9 0 /8 port 6 8 Y L L n-/, /8. P = R. 9 R-side U-side D-side 89 (Single) 86 (Double) 96 ( position) ottom ported L-side PE port L: Dimensions n: (, port) /, /8- port, port Formula L = n + 6 L = n VP S S VS N

304 Series 7-8 Dimensions 7-8-FG-S-M0 Manual override Indicator light (0) ( port) P (0) ( port) R P R P M connector 0 6 (7) 7 (86) 9 (6) 9 (6) -ø8 mounting hole (6) 9(6) () () (0) 8 8 (0) (8) (8) ottom ported -ø8 mounting hole () 0 (6) () 6 6 () 6(7) 7(86) /8- port, port /8, /, /- port,,,, port 7-8-FG-D-M0 Manual override Indicator light PE port 8 () /8 port PE port 0 P 8 () /8 port (0) ( port) 6 (0) ( port) R 9 (6) 6. P 0 () 0 () R 9 (6) 0 () 0 () P M connector 8 -ø8 mounting hole /8, /, /- port, port /8, /, / port /8, /, /- port, port PE port (0) (0) () 0 (6) /8, /, / port 0 () 6 (7) 0 (6) 7 (86) 6. (9.) 08. (.) 6. (9.) Manual override Indicator light PE port 8 () /8 port 0 P /8 port R Y H 7-8-F JI G-D-M0 0 () P () R (0) (, port) P 8 () 6 (0) ( port) 6 (0) ( port) 9 (6) SMC (6) /8, /, /- port, port M connector -ø8 mounting hole /8, /, /- port, port /8, /, / port (7) 7 (86) (0) () 0 (6) 6. (9.) PE port Dimension inside is for rubber seal. Dimensions inside ( ) are for Sub-plate. --8

305 P Conforming to ISO Standard Solenoid Valve (with M Connector) Series 7-9 Dimensions 7-8-FPG-D-M (0) ( port) 6 (0) ( port) VV7-- (M connector type) Manual override L-side -/8, port 6-/, /,, port R P 8 U-side P R. () () M connector SMC P R 9 Indicator light R-side D-side 0 7. (Single) 6. (Double). 6. ( position) 8 8 (7) P Manual override Indicator light PE port L L 0 (.) 8 () R (-/8),, port Only for / 9 7 P 9 (6) 9 (6) (n-/8) P P P P P P = 6 60 (7) 0 () 7 L: Dimensions n P, R, R port Rc / Rc / L L L L L /8, /, /- port /8 port 0 () 0 (), port /8, /, / port R M connector SMC (0) () n-/8, /, port 6 (7) -ø8 mounting hole PE port 0 (6) (97) 7 (86) L L Dimensions inside /8 port P = 6 60 (7) Dimensions inside ( ) are for Rc /. Dimensions inside are for rubber seal. Y (0) (, port) n-/8, / 9 R. 8 () /8, /, /- port, port are for rubber seal. 8 U-side R-side L-side D-side 0 7. (Single) 6. (Double). 6. ( position) ottom ported PE port n: Formulas L = 6n + 6 L = 6n + 80 L = 6n + 90 L = 6n + 06 VP S S VS N --9

306 Series 7-0 Dimensions 7-0-FG-S-M0 ( port) ( port) ( port) ( port) 7 9 /, /- port,,,, port -ø8. mouting hole 7-0-FG-D-M0 Manual override Indicator light PE port ( port) SMC Manual override /, /, port Indicator light 6 80 PE port 6 8 E 8 P E M connector ( port) ( port) ( port) SMC 0 -ø8. mounting hole PE port E /, /, port 80 9 /- port, port M connector P 9 6 E ø8. mounting hole /- port, port 7 0. H 7-0-F JI G-D-M0 Manual override Indicator light PE port SMC /8- port, port ( port) /, /, port SMC E ottom ported 7 (, port) P E M connector 7 /, /, - port, port ( port) ( port) /8- port, port ( port) SMC -ø8. mounting hole PE port 7 0 /- port, port

307 Conforming to ISO Standard Solenoid Valve (with M Connector) Series -0/-0 (Size ) (Size ) Large capacity -0 (Size: 0) -0 (Size: 0) Lightweight Size 0 ( position): 0.6 kg Size 0 ( position): 0.8 kg Flow rate 000 l/min (NR) 00 l/min (NR) Cylinder driving size ø00 ø80 ISO 07- Interface Size 0 (-0) and Size 0 (-0) Interface conforms to ISO 07- ccommodates enclosure IP6 Dust/Splashproof type VP S S VS N --

308 ISO Standard Solenoid Valve Size,/Single Unit Series -0/-0 How to Order Valve 0 FG S M0 Size Thread type Sub-plate FG FHG FJG FIG Size 0 Size 0 Passage symbol ()() (R)(P)(R) () () (R)(P)(R) ()() (R)(P)(R) ()() (R)(P)(R) Number of solenoids S Single D Double 9 VS Piping specifications Side ported /8 Side ported / Rated coil voltage VDC VDC Voltage other than above (0 VDC or less) Size Size 0 Size 0 Size 0 Port size 0 Size 0 Specifications Model VS-0-0 VS-0-0 VS-0-0 Piping direction Horizontal Horizontal Nil F T Port size Nil 0 0 Piping specifications Without sub-plate Side ported /8 Side ported / Size 0 Sealing type Nil Metal seal R Rubber seal Option Nil None Z Light/Surge voltage suppressor Thread type Nil Rc F G T NPTF Piping specifications Port size for (P), (), () /8 / /8 Rc G NPTF Port size for (R), (R) Size 0 Weight (kg)

309 Conforming to ISO Standard Solenoid Valve (with M Connector) Series -0/-0 Model Series -0 position position Positions Single Double Closed center Exhaust center Pressure center Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Flow characteristics, (P, ),, (, E, E) C b Cv C b Cv Series -0 position position Positions Single Double Closed center Exhaust center Pressure center Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Flow characteristics, (P, ),, (, E, E) C b Cv C b Cv Note) Values for position single from the cylinder port to the exhaust (from to and from to ) C (Sonic conductance) and b (Critical pressure ration) are subject to ISO 68/JIS 890. Cv (Flow coefficient) is subject to NSI/CNFP T... VP S S VS N --

310 Series -0/-0 JIS position single ()() (R)(P)(R) position double (metal) ()() (R)(P)(R) position double (rubber) ()() (R)(P)(R) position closed center ()() (R)(P)(R) position exhaust center ()() (R)(P)(R) position pressure center ()() Standard Specifications Valve specifications Electric specifications Valve type Fluid Maximum operating pressure Minimum operating pressure Caution (R)(P)(R) Single Double position mbient and fluid temperature Lubrication Manual override Impact resistance/vibration resistance Enclosure Rated coil voltage llowable voltage fluctuation Type of coil insulation Power consumption VDC (Current) VDC Internal Wiring Specifications port side SOL port side SOL DC: Single ZNR COM ZNR ZNR DC: Double port side SOL Metal seal ir, Inert gas.0 MPa 0. MPa 0. MPa 0. MPa 0 to 60 C () Rubber seal 0. MPa 0. MPa 0. MPa to 60 C () M8 Connector: Wiring specifications (-0) Not required (Non-lube type) Push type (Tool required) 0, 0m/s () IP6 (Dust/Splashproof type) VDC, VDC ±0% of rated voltage Equivalent to class W DC ( m) W DC (8 m) Note ) Use dry air to prevent condensation at low temperatures. Note ) Impact resistance: No malfunction resulted during an impact test using a drop impact tester. The test was performed one time each in the axial and right angle directions of the main valve and armature for both energized and de-energized conditions. Vibration resistance: No malfunction resulted during an one-sweep test between 8. and 000 Hz. The test was performed in the axial and right angle directions of the main valve and armature for both energized an de-energized conditions. Precautions Pin no. : Open : port side SOL (+) : COM ( ) : port side SOL (+) M Connector: Wiring specifications (-0) Pin no. : Open : port side SOL (+) : COM ( ) : port side SOL (+) : Ground --

311 Conforming to ISO Standard Solenoid Valve (with M Connector) Series -0/-0 Dimensions -0-FG-S-M ( port) 7. ( port) 0. ( port) 0. ( port) Indicator light Manual override -0-FG-D-M0 Indicator light Manual override PE port PE port ( port) 7. ( port) 0. ( port) 0. ( port) SMC M connector 9 SMC 6.. M connector /8, / port 6 -ø. mounting hole PE port 0. /8, /- port, port /8, / port ø. mounting hole 9 /8, /- port, port M- port, port H -0-F JI G-D-M0 Indicator light Manual override PE port 0. (, port) 0 (, port) ( port) 7. ( port) 0. ( port) 0. ( port) SMC /8, /- port, port M connector /8, / port 6 -ø. mounting hole PE port /8, /- port, port VP S S VS N --

312 Series -0/-0 6 Dimensions -0-FG-S-M ( port). ( port) 8. ( port) 8. ( port) 8 Indicator light Manual override M8 connector -ø.6 mounting hole -0-FG-D-M0 Indicator light Manual override PE port PE port ( port). ( port) 8. ( port) 8. ( port) SMC 6 M8 connector 6 /8 port SMC 6 6 /8 port 8 -ø.6 mounting hole PE port 8.. /8- port, port /8- port, port M- port, port H -0-F JI G-D-M0 Indicator light Manual override PE port 9 (-, port). (-, port) /8- port, port ( port). ( port) 8. ( port) 8. ( port) SMC M8 connector 8 -ø.6 mounting hole PE port 6 6 /8- port, port /8 port

313 7 Product Profile: ISO Interface Solenoid Valve, ISO 99/II Rubber Seal/Metal Seal Series VSR8/VSS8 Choice of seals for maximum flexibility vailable in either high flow rubber seal (model VSR) or matched ground spool and sleeve (model VSS). Low power consumption.8 W DC vailable in or position, single or double solenoid pilot configuration. Long service life Rubber seal: 0 million cycles or more Metal seal: 0 million cycles or more Subject to SMC s own test data using clean and dry air. Lightweight Size : g (. lb) Size : 8 g (.8 lb) Size :,000 g (. lb) Top mounted manual override Easy access for trouble shooting the circuit Model Size Model Effective area Seal (Cv) VSR8-6 VSR8-8 Rubber Rubber 6 (.0) 7 (.0) VSS8-6 VSS8-8 Metal Metal (.8) 6 (.6) VSR8-0 Rubber 97 (.) (.) /, /, VSS8-0 Metal 90 (.0) 0 60 Note ) With port size / for VSR/VSS8-6, / for VSR/VSS8-8, for VSR/VSS8-0. Note ) Subject to JIS t 0. MPa (7 psi) Note ) Single solenoid type without base. Specifications Rubber seal Metal seal Valve operation Fluid Pilot operated, port ir, Inert gas Operating pressure range MPa (psi) Proof pressure MPa (psi) mbient and fluid temperature C ( F) () Max. operating frequency (cycle/sec) 0. to.0 (. to ). (7) to +0 (+ to +) 8-6: ; 8-8:, 8-0: 8-6: ; 8-8:, 8-0: 0. to.6 (. to 0) Note). (8) 0 to +60 ( to +0) 8-6: 0; 8-8:, 8-0: 0 8-6: 0; 8-8: 0, 8-0: 0 Lubrication Manual override Enclosure Coil rated voltage llowable voltage range (%) Coil insulation Not required Non-locking push type Dusttight 00 VC, 0 VC, 00 VC, 0 VC, VDC to +0% of rated voltage Class or equivalent 0 Hz.6 pparent Inrush 60 Hz.0 power 0 Hz. (V) Holding 60 Hz. Power consumption (W) Surge voltage suppressor and indicator light.8 vailable as option Note ) Pilot pressure range should be 0. to MPa (. to psi). Note ) Use dry air to prevent dew condensation when operating at low temperature. Note ) Subject to JIS For details, please contact SMC. () () Response time m (sec) () Weight Single Double position g (lb) Port size (.) /, /8, / 8 (.8) /8, /, / VP S S VS N --7

314 8 Manifold Specifications Size Number of stations station Size Size Size 0 0 stations Note) SU and TU require one station. Location and size of, port Standard Specifications Maniflod block size pplicable solenoid valve Number of stations, port Port size P, E, P port Individual SUP spacer Individual EXH spacer Interface speed control Interface regulator lanking plate assembly ISO Size VSR/S8-6 VV8-P-0/0/0 VV8-R-0/0/0 VV8060- R NR0-N0-- VVS8060- How to Order Manifold VV8 0 0 D T Side / Side /8 Side / Side / SIde ottom / ottom /8 ottom / Option Nil TU SU W ISO Size VSR/S8-8 to 0 /, /8, /, /, /, /8, /, /, VV8-P-0/0/06 VV8-R-0/0/06 VV8080- R NR0-N0-- VVS8080- Nil T F Port thread Rc NPTF G Location of P, E, E port D U ottom Top Size of P, E, E port / /8 / / None With terminal box With SI unit Splash proof ISO Size VSR/S8-6 VVS

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry

More information

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000) 5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust

More information

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Body Ported Base Mounted Series S000 S000 S000 S000 S000 S4000 S5000 Sonic conductance C [dm /s bar)] 4/ 5/(A/B R/R) Single Double.8.4

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR2 JIS Symbol type

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Manifold Specifications

Manifold Specifications Specifications Specifications Base mounted VVFR-01 VVFR- VVFR-0 Wiring With terminal block With multi-connector With D-sub connector Grommet terminal DIN terminal Grommet Grommet terminal Conduit terminal

More information

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series VZS Series Variations Plug-in Type Base Mounted Type (With sub-plate) Non Plug-in Type Base Mounted Type (With sub-plate) Series Sonic conductance

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model 2 position 3 position

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Series VQ Rubber Seal Space-saving profile Clean space saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

Manifold Specifications Stacking Type

Manifold Specifications Stacking Type Specifications Stacking Type Keeps environmental air clean from pilot exhaust Use of the VV5FS- manifold can exhaust intensively the pilot exhaust gas to the base side, and can prevent environmental aggravation

More information

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Series 000 Compact and lightweight: 3 mm width Compact yet provides

More information

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating / ort Solenoid Valve ubber Seal Series SYJ000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Specifications JIS Symbol port port (manifold) position

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

Series VQZ1000/2000/3000 Single Unit

Series VQZ1000/2000/3000 Single Unit +- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body

More information

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

0.35 W (Without light)

0.35 W (Without light) Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Rubber Seal Series VQ Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

Series SV1000/2000/3000/4000

Series SV1000/2000/3000/4000 Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double

More information

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000 D-sub Connector J Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000//000 Number of connectors: pins MIL-C-08 Conforming to JIS-X-0 --6 For details

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Port Solenoid Valve Metal Seal Rubber Seal Series Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing

More information

VQ1000. How to Order Manifold. Kit type

VQ1000. How to Order Manifold. Kit type - - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold

More information

Manifold Specifications

Manifold Specifications Specifications Plug-in Type: With Terminal Block Since lead wires of solenoid valve are connected with the terminals on upper surface of terminal block, corresponding lead wires from power source can be

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type20P 5 Port Solenoid Valve ody Ported Manifold ar Stock Type/Flat Ribbon Cable Series SY3000/5000/7000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 5 20P 05 Manifold series 3 SY3000

More information

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000

More information

3 Port Air Operated Valve

3 Port Air Operated Valve Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation

More information

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Soft Start-up Valve. AV2000/3000/4000/5000 Series Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off

More information

5 Port Air Operated Valve

5 Port Air Operated Valve Port ir Operated Valve Series VF000/000/000 RoHS 22- Series VF000/000/000 Model Selection by Operating Conditions q ir Operated Valve: Single Unit Series Sonic conductance C[dm /(s bar)] Type of actuation

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve CT.ES8 / ort Solenoid Valve Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M.7 to M2. 앬 Flow Characteristics Series Cover (stainless

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 0 PW COM Rubber Seal Port Solenoid Valve Series SZ000 Cassette Type Manifold The plug-in cassette system makes valve replacement easy. plug-in manifold has been created with a height of. mm (including

More information

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I ISO Standard Solenoid Valve Series VQ7-6/7-8 (Size ) (Size ) Conforms to ISO Standard /I.0- Ideal for driving cylinders up to Large flow capacity ø00 (VQ7-6, Size ) ø60 (VQ7-8, Size ) Nl/min VQ7-6: 668.

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M. V3 Cover

More information

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308 Cable ppendix Cable ppendix Multi-way cables The multi-pole connector cables used on SMC valves are common across several ranges. Cables are available in accordance with the MIL standard C-08 and also

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve ubber Seal / ort Solenoid Valve Series 000 / 000 / 000 [Option] SJ SY SV SZ V S000 VQ VQ VQ VQC VQZ SQ VFS VF VQ Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot 3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in

More information

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit CT.EUS8 UK ower Consumption / ort Solenoid Valve With ower Saving Circuit Series SYJ000/000/7000 Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable

More information

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring Type4 SY000/000 ase Mounted Monifold Stacking Type/DIN ail Mounted Individual Wiring How to Order Manifold SSY 4 0 U C6 How to Order Valve Manifold ssembly Ordering example SY000 SY000 Valve stations 02

More information

3 Port 3 Position Valve

3 Port 3 Position Valve Port Position Valve Pilot Solenoid ir Operated ohs Intermediate stopping of cylinders * up to ø15 is possible. Pilot solenoid Manifold ir operated * For VEX 4, 00 mm/s, horizontal movement Power consumption:

More information

5 Port Pilot Solenoid Valve Metal Seal. Configuration Voltage Electrical entry Option. Standard. 100V AC50/60Hz 200V AC50/60Hz 24V DC.

5 Port Pilot Solenoid Valve Metal Seal. Configuration Voltage Electrical entry Option. Standard. 100V AC50/60Hz 200V AC50/60Hz 24V DC. 5 Port Pilot Solenoid Valve Metal Seal SeriesVFS Models and Variations Body ported Base mounted Series VFS000 VFS2000 VFS3000 VFS2000 VFS3000 VFS4000 VFS5000 Port Size Effective area (mm 2 ) (Nl/min) 8:

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type1P Type2P 5 Port Solenoid Valve ase Mounted Manifold ar Stock Type/Flat Ribbon Cable Series /5000/000 How to Order Manifold Type 1P/Compact style SS5Y 5 1P 05 C8 Manifold series 3 5, port size Thread

More information

ISO Standard Solenoid Valve/SIZEq Rubber Seal Series VP7 6

ISO Standard Solenoid Valve/SIZEq Rubber Seal Series VP7 6 ISO Standard Solenoid Valve/SIZq Rubber Seal Series VP7 6 VP7 6 FPG D VP7 6 FG D position position Single solenoid (FG-S) Double solenoids (FG-D) Reverse pressure (YZ-S) Reverse pressure (YZ-D) Closed

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold Port Solenoid Valve VV00 Series Highly Integrated Unit Manifold po ted - pera irect-o d station es on rt valv ally ividu Ind wired n be ve ca val d. adde ector Con-inn connection) lug (For p ø connection

More information

5 Port Solenoid Valve Plug Lead Type

5 Port Solenoid Valve Plug Lead Type 5 Port Solenoid alve Plug Lead Type Series Body Ported Flow rate characteristics For single/double solenoid C [dm 3 /(s bar)]: 0.6 Single Unit alve width: 7.4 mm Possible to drive cylinders: Up to ø32

More information

Flow characteristics Max. (1) b Standard Specifications. P Manual override.

Flow characteristics Max. (1) b Standard Specifications. P Manual override. Port Direct Operated Solenoid Valve Series 0 Metal Seal Model Number of positions (Single) (Double) ( position) JIS Symbol Model Port size Rc (Nominal size) 0-0 8 ( A) 0- ( 8A) 0-0 8 (0A) 0-0 8 ( A) 0-

More information

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection Rubber Seal Port Solenoid Valve Series SJ000/000 Cassette Type Manifold 0 mm 7. mm (SJ000) 0 mm (SJ000) Non plug-in type Individual wiring manifold SJ000 SJ000 Can be mounted together. Connecter connection

More information

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot ubber seal ort ilot Solenoid Valve Series SYJ00 Specifications efer to www.smcworld.com for details of products compatible with overseas standards. Body ported Base mounted Fluid Operating pressure range

More information

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Vacuum Release Valve with Restrictor Series SJ3A6 SJ Plug-in Type Connector Connection P.86 D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Non Plug-in Type Individual

More information

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is. Port Solenoid Valve Series VQ 00 Unprecedented high speed, stable response, and extra-long service life. ON:.ms, OFF: ms, Dispension accuracy ±ms (With indicator light and surge voltage suppressor; supply

More information

How to Order Manifold. Kit type L8 B4 B6 B8 LM

How to Order Manifold. Kit type L8 B4 B6 B8 LM 0 Stations station VVQ Series VQ000 The maximum and minimum number of are varied depending on. (Refer to the table below.) Series VQ000 ase Mounted Plug-in Unit Manifold Plug-in unit 08 C Cylinder port

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series 1 Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

Coolant Valve. Air Operated/External Pilot Solenoid

Coolant Valve. Air Operated/External Pilot Solenoid Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) lange type (3 to ) Low water hammer or details, refer to page

More information

Example. U side. Stations SY5000

Example. U side. Stations SY5000 45 Type 5 ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN ail Mounted/Individual Wiring Series SY3000/5000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 3 45 05 U C6 Example

More information

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1 Port Solenoid Valve Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Non plug-in manifold 0 0 S 60 Stations stations 0 stations SUP/EXH

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes

More information

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) type (3 to ) Low water hammer or details, refer to page 07. Large

More information

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve CT.E- ase Mounted Type Series VQ Port Metal Seal/Rubber Seal Solenoid Valve dvanced manifold va the new age of factory au ase Mounted Type Space saving profile Clean space saving design with all pilot

More information

3 Port Solenoid Valve

3 Port Solenoid Valve 3 ort Solenoid Valve Series VKF300 ubber Seal Direct Operated oppet Type Compact yet provides a large flow capacity Body width 8 mm vailable in vacuum applications ( 0. ka) Can be used in vacuum/release

More information

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal Port Solenoid Valve Cassette Type Manifold Rubber Seal 7.mm (SJ000) SJ000 SJ000 Can be mounted together. 0mm (SJ000) Connector connection New New cable type manifold is added! New Additional options are

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 044 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000 racket

More information

Rubber Seal VP300/500/700

Rubber Seal VP300/500/700 Port Pilot Operated Poppet Rubber Seal 00/500/700 High flow capacity Cv1.0 (00), Cv. (500), Cv.0 (700) Low power consumption: 1.8W(DC) Possible to use as either selector valve or divider valve Changeable

More information

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04 Three functions (pressure regulator, switching valve, and speed controller) are provided by a single valve. The conventional valve combination circuit has been condensed into a single valve. A large capacity

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry TEX Compliant Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 44 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000

More information

High Pressure Coolant Valve

High Pressure Coolant Valve High Pressure Coolant Valve Series.5 MPa, 7.0 MPa Corresponding to high speed grinding and long drilling processes Coolant valve for high pressure coolant liquid (up to.5 MPa or 7.0 MPa) that is ideal

More information

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type. Series -S00 ompact Direct Operated Port Solenoid Valve ontrol Valves ase mounted ody ported lean Series lean Series V S R oil voltage 24 VD VD VD VD VD Power consumption Pressure specification Flow rate

More information

Base Mounted Plug-in/Plug Lead: Single Unit

Base Mounted Plug-in/Plug Lead: Single Unit ase mounted VQ ase Mounted lug-in/lug Lead: Single Unit Model Number of solenoids Model Single Metal seal VQ Rubber seal VQ ouble Metal seal VQ Rubber seal VQ Closed Metal seal VQ VQ center Rubber seal

More information

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer Base Mounted Metal Seal/Rubber Seal VQ Built-in silencer, direct exhaust Space-saving profile All pilot valves are compactly mounted on one side. The space-saving design of mounting all fittings on one

More information