Specifications. Fluid Ambient and fluid temperature ( C)
|
|
- Clifton Oliver
- 5 years ago
- Views:
Transcription
1 Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication Mounting position Impact / vibration resistance (m/s ) Enclosure Note ) Solenoid specifications Air 0 to 0 (With no freezing. Refer to page 74.) ON: or less, OFF: 4 or less 0 Non-locking push type, push-turn locking slotted type Not required Unrestricted 0/0 Dust tight Note ) Based on dynamic performance test, JIS B (Standard type : temperature 0 C, at rated voltage, without surge voltage suppressor) Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Initial value) Vibration resistance: No malfunction occurred in one sweep between 4 and 000Hz. Test was performed in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states. (Initial value) JIS Symbol 0-V4 (A) 0-V4 (A) Series Electrical entry rated voltage V Allowable voltage fluctuation Power consumption (W) Apparent power (VA) Surge voltage suppressor Indicator light DC AC 0 /60Hz AC DC 00V 0V [V] 00V 0V [0V] 0-V4/V4 0-V4A/V4A Grommet (G)/(H), L plug connector (L) M plug connector (M) 4,, 6,, 00, 0, 00, 0 0 to 0% Standard: 0. (With indicator light: 0.4) With power saving circuit: (With indicator light: 0.8) 0.86 (With indicator light: 0.89) 0.94 (With indicator light: 0.97).8 (With indicator light:.).0 (With indicator light:.4) [.4 (With indicator light:.46)] Refer to page 647. LED W (With indicator light:.) In common between 0VAC and VAC, and between 0VAC and 0VAC. For VAC and 0VAC, the allowable voltage fluctuation will be % to % of rated voltage. 68
2 port solenoid valve 0-V00 Model Valve model 0-V4 0-V4A 0-V4 0-V4A Note ) Note ) Note ) Type of Operating pressure Vacuum specification (MPa) Port size Weight (g) Type actuation range (MPa) Port Port Ports, Port Grommet type L/M plug connector N.C. Standard N.C. Large flow capacity N.O. Standard N.O. Large flow capacity 0 to to to to kPa to kPa to kPa to 0 00kPa to 0 00kPa to 0 00kPa to 0 00kPa to kPa to V 4: (7) 0-V 4A: 6(0) 0-V 4: (6) 0-V 4A: (9) Air cylinder Valve model 0-V4 0-V4A 0-V4 0-V4A Note ) Note ) C[dm /(s bar)] b Cv Note ) 0-V4 and 0-V4A: Supply pressure to port and exhaust from port. Note ) ( ): With sub-plate Flow characteristics C[dm /(s bar)] b Cv Clean gas filter Rotary actuator Air gripper Pressure switch Air preparation Fittings & Tubing Filter, Pressure control Flow control Directional control valve 69
3 port solenoid valve 0-V00 How to Order Standard type Base mounted 0 V 4 M port Clean series Port size Nil: Without sub-plate M: With sub-plate For sub-plate type, For manifold type S4 Type of actuation Normally closed Normally open (With gasket and screws) specifications Nil 0.W 0. W (with power saving circuit) T (4 VDC and VDC only) All types with power saving circuit are with light/surge voltage suppressor. For DC 6 V S R Rated voltage 4 VDC VDC 6 VDC VDC VDC For AC (0/60Hz) 00 VAC 00 VAC 0 VAC [ VAC] 4 0 VAC [0 VAC] Manual operation Nil: Non-locking push type B: Locking slotted type Electrical entry 4,, 6,, VDC / 00, 0, 00, 0 VAC Grommet L plug connector M plug connector G: Lead wire L: With lead wire length 00 mm (Lead wire length 00 mm) H: Lead wire length 600 mm M: With lead wire MN: Without (Lead wire length 00 mm) lead wire Light/Surge voltage suppressor Nil S Z R U Without light/surge voltage suppressor With surge voltage suppresser With light/surge voltage suppresser With surge voltage suppresser (Non-polar type) With light/surge voltage suppresser (Non-polar type) Power saving circuit is only available in the "Z" type. DC, AC specifications DC specifications DC, AC specifications DC specifications + - LN: Without lead wire LO: Without connector MO: Without connector -+ "LN", "MN" type: with sockets. 640
4 port solenoid valve 0-V00 How to Order Large flow type Base mounted 0 V 4 A M Air cylinder port Clean series Port size Nil: Without sub-plate M: With sub-plate Rotary actuator For sub-plate type, For manifold type S4 Type of actuation Normally closed Normally open Large flow type (With gasket and screws) Manual override Nil: Non-locking push type Air gripper Directional control valve Rated voltage For DC 6 V S R 4 VDC VDC 6 VDC VDC VDC B: Locking slotted type Flow control Filter, Pressure control Electrical entry 4,, 6,, VDC Grommet L plug connector M plug connector Light/surge voltage suppressor Nil R U Without light/surge voltage suppressor With surge voltage suppresser With light/surge voltage suppresser For DC Fittings & Tubing G: Lead wire Length 00 mm H: Lead wire Length 600 mm L: With lead wire M: With lead wire MN: Without (Length 00 mm) (Length 00 mm) lead wire Air preparation LN: Without lead wire LO: Without connector MO: Without connector Pressure switch "LN", "MN" types: with sockets. -+ Clean gas filter 64
5 port solenoid valve 0-V00 Base mounted (with sub-plate) Grommet (G)/(H): 0-V 4(A)- -M G H (Light/surge voltage suppressor). Note) [ ]: AC < >: Large flow type (A) 0 L plug connector (L): 0-V4(A)- L -M M plug connector (M): 0-V4(A)- M -M. 9.6[46.6] <4.> 40.7[4.9] <4.9> 0.9[.] <.>.9. -ø.6 (For mounting) G: Approx. 00 H: Approx. 600 (Lead wire length) 8. [.] <.4>.7 0.8[] <> (Piping port) 9 (Light/surge voltage suppressor) (Light/surge voltage suppressor) Approx. 00 (Lead wire length) Approx. 00 (Lead wire length) Other dimensions are same as grommet style. Other dimensions are same as grommet style. 64
6 Series 0-V00 port solenoid valve Manifold specifications Manifold specifications Model Manifold P (SUP), R (EXH) Stations Output port Porting specifications Port size Location Direction,, port S4 type Single base / B mount Common SUP / Common EXH to 0 stations Base Side Note ) 0-V4(A) and 0-V4(A) cannot be mounted on the same manifold. Note ) For 0-V4(A), supply pressure to port and exhaust from port. Air cylinder Rotary actuator Flow characteristics Air gripper Manifold 0-VV00-S4 type 0-V4 0-V4A 0-V4 0-V4A Port size,, port C[dm /(s bar)] b Flow characteristics Cv C[dm /(s bar)] b Cv Directional control valve Note) Values when manifold base ( stations) is mounted. How to Order Valve Manifold Assembly Ordering example Flow control Valve (N.C.) 0-V4-GZ Stations 4 Filter, Pressure control Fittings & Tubing Pressure switch Clean gas filter Manifold base ( stations) 0-VV00-S4-0-M 0-VV00-S4-0-M set (S4 type station manifold part no.) V00-77-A set (blanking plate assembly part no.) 0-V4-GZ 4 sets (valve) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Indicate part numbers of valve and option beneath the manifold part no. Blanking plate assembly V00-77-A Air preparation 64
7 Manifold specifications 0-V00 Common SUP / Common EXH S4 type Port How to Order 0 Port Port VV00 S4 0 Clean series 0 0 Stations stations 0 stations M port size M Note) 0-V4(A) and 0-V4(A) cannot be mounted on the same manifold. Applicable solenoid valve Note) 0-V4-0-V4A- 0-V4-0-V4A- Applicable blanking plate assembly V00-77-A (Manifold option) Blanking plate assembly Part no: V00-77-A Place notch mark on the blanking plate to port side when assembling. Round head combination screw Notch mark Blanking plate Gasket Base Sub-plate 0- VV00-S4 type manifold base 644
8 Manifold specifications 0-V00 Type S4 manifold: Side ported / 0-VV00-S4- Stations -M Note) [ ]: AC < >: For large flow type (A) Grommet (G), (H) (Pitch) P=0.. Rotary actuator Air cylinder G: Approx. 00 H: Approx. 600 (Lead wire length) Air gripper Directional control valve Flow control L plug connector (L) 7[4] <0.9>..6 0 L L.4[4.6] <4.6> 7.7 M plug connector (M) Filter, Pressure control -ø. (For mounting) (Light/surge voltage suppressor) (, port) (Station n) (Station ) ( port) (Pitch) P= [4.7] <4.7> Fittings & Tubing 4.[44.] <44.> 8.[4.] <4> Air preparation 7. Pressure switch Other dimensions are same as grommet style. Other dimensions are same as grommet style. Stations L L stations stations. 6. Clean gas filter 64
9 Series 0-V00 Specific Product Precautions Be sure to read before handling. Warning Manual override operation Since connected will be actuated when the manual override is operated, first confirm that conditions are safe. Non-locking push type [Standard] Press in the direction of the arrow. Locking slotted type [B] Turn in the direction of the arrow. Caution How to use plug connector. Attaching and detaching sockets with lead wires Attaching Insert the sockets into the square holes of the connector (with + and indication), and continue to push the sockets all the way in until they lock by hooking into the seats in the connector. (When they are pushed in, their hooks open and they are locked automatically.) Then confirm that they are locked by pulling lightly on the lead wires. Detaching To detach a socket from a connector, pull out the lead wire while pressing the socket's hook with a stick having a thin tip (approx. mm). If the socket will be used again, first spread the hook outward. Caution How to use plug connector Caution. Attaching and detaching connectors To attach a connector, hold the lever and connector unit between your fingers and insert straight onto the pins of the solenoid valve so that the lever's pawl is pushed into the groove and locks. To detach a connector, remove the pawl from the groove by pushing the lever downward with your thumb, and pull the connector straight out. Cover Groove Pin Cover Groove Pin Connector When operating with a screwdriver, turn it gently using a watchmaker's screwdriver. [Torque: Less than 0. N m]. Crimping of lead wires and sockets Strip. to.7 mm at the end of the lead wires, insert the ends of the core wires evenly into the sockets, and then crimp with a crimping tool. When this is done, take care that the coverings of the lead wires do not enter the core wire crimping area. Use special tool when crimping. (For the crimping tool, please consult with SMC.) -+ Hook Lever DC polarity indication Socket Lead wire Socket Plug connector lead wire length How to Order Connector Assembly For DC : SY00 0 4A For 00 VAC : SY00 0 A For 00 VAC : SY00 0 A For other voltages of AC : SY00 0 A For DC 0-V4-LO SY00-0-4A-0 Hook Without lead wire : with connector and pcs. of sockets only SY00 0 A For AC 0-V4A-LO SY00-0-A-0 Connector Lead wire Standard length is 00 mm, however, the following lengths are also available. How to Order Indicate part numbers of the valve without connector and the required connector assembly separately. <Example> Lead wire length 000 mm Lead wire length Nil mm 600mm 000mm 00mm 000mm 00mm 000mm 000mm Core wire crimping area Socket Hook Crimping area Core wire Lead wire Insulation 0. to 0. mm Max. cover diameter: ø.7 mm 646
10 Series 0-V00 Specific Product Precautions Be sure to read before handling. Surge voltage suppressor (For DC) Grommet, L/M plug connector Standard type (with polarity) With surge voltage suppresser ( S) Working principle Red (+) Black ( ) Electric waveform for power saving type : V 4T Applied voltage 4V 0V 0.4W 0.W 0W Diode to prevent reverse current 6ms With light/surge voltage suppresser ( Z) Red (+) Black ( ) Diode to prevent reverse current Non-polar type With surge voltage suppresser ( R) ( ) (+) (+) ( ) Varistor With light/surge voltage suppresser ( U) ( ) (+) (+) ( ) With power saving circuit Power consumption is reduced by approximately 7% compared with the standard product by eliminating the need for electrical current for holding. (Effective after more than 6ms energized and 4 VDC rated voltage applied.) <For AC> Grommet, L / M plug connectors With indicator light ( Z) (~) (~) Caution Z N R Varistor Please connect correctly the lead wires to + (positive) and (negative) indications on the connector. For DC voltages other than and 4 VDC, use caution not to connect in reverse due to the absence of a diode to prevent reverse current. (Wrong polarity will cause trouble.) Solenoids, whose lead wires have been pre-wired: positive side red and negative side black. The electrical circuit as shown above, allows reduced holding current consumption and measures power saving. Refer to electric waveform on the right. When a power saving circuit is installed, a diode to prevent reverse current is not provided. Therefore, use caution not to connect in reverse. Electrical Circuit (with power saving circuit) Red (+) Standard With power saving circuit In the case of ZNR surge voltage suppressor, take note the surge voltage to be suppressed at controller side as there will be a residual voltage according to the protective element and rated voltage. Moreover, the residual voltage of the diode is approximately V. Timer circuit LED Diode Black ( ) : Starting current : Holding current Connector assembly with cover Connector assembly with protective cover enhances dust protection Effective in preventing possible short circuit problems due to contaminants in contact with connector section Cover material is chloroprene rubber which has excellent weatherability and electric insulation properties. However, be careful not to allow contact with cutting oil, etc. Round cord provides neat appearance. How to Order SY A - Lead wire length (L) Nil mm 600mm 000mm 00mm 000mm 00mm 000mm 000mm Connector assembly with cover / Dimensions (8) (Ø4.) Gray L Red (40) Black (0) Connector Connector (4.) How to Order Specify the part numbers of the solenoid valve without connector together with the part number of the connector assembly with protective cover. <Example> Lead wire length 000 mm 0-V4-LOZ-M SY00-68-A-0 <Example >Lead wire length 00 mm (Standard) 0-V4-LPZ-M (6.9) (8) Symbol of connector assembly with protective cover No part numbers of connector assembly with cover are needed to be indicated in this case. Air cylinder Rotary actuator Air gripper Directional control valve Flow control Filter, Pressure control Fittings & Tubing Air preparation Pressure switch Clean gas filter 647
3 Port Solenoid Valve
Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series
More informationExhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)
5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body
More informationSeries VQ Port Solenoid Valve
Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body
More information3 Port Solenoid Valve
Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body
More informationManual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry
Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal
More information3 Port Solenoid Valve
ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M. V3 Cover
More information3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)
ort Solenoid Valve ubber Seal Series SY00 Low power consumption: 0.W (Standard, Without light) (Current draw: m at V DC) Large flow capacity style:0.7w (Current draw: m at V DC) Body width: 0mm 7.8 Nl/min
More information5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal
Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage
More informationSeries VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4
Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double
More information5 Port Solenoid Valve Direct Operated Poppet Type. Specifications
Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W
More informationSeries SYJ300/500/700
ort Solenoid Valve ubber Seal Series SYJ00/00/00 Low power consumption: 0.W (Without light) (Current draw: 1m at 4V DC) Completely interchangeable ilot exhaust with the previous series VJ00/00/00 and VZ00/00.
More information3 Port Solenoid Valve Direct Operated Poppet Type
3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage
More information3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.
3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118
More information10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry
Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available
More information5 Port Solenoid Valve Direct Operated Poppet Type. Specifications
Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W
More information1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold
Port Solenoid Valve VV00 Series Highly Integrated Unit Manifold po ted - pera irect-o d station es on rt valv ally ividu Ind wired n be ve ca val d. adde ector Con-inn connection) lug (For p ø connection
More information4 Port Solenoid Valve
Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean
More information4 Port Solenoid Valve
Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean
More information3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option
Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable
More information1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions
Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]
More informationSeries VKF300 VV061 V100 S070 VQD VKF VK VT VS
Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing
More informationBase Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC
Base Mounted Series VQZ00/00/00 VQZ00/00 / How to Order Valve Made to Order (For details, refer to page 9 and 4.) VQZ 5 5 M Series VQZ00 body width 5 mm VQZ00 body width 8 mm Type of actuation 4 N.C. N.O.
More informationVacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm
4 Port Direct Operated Poppet Solenoid Valve Series D1000 High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure
More information3 Port Air Operated Valve
Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation
More informationRubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot
ubber seal ort ilot Solenoid Valve Series SYJ00 Specifications efer to www.smcworld.com for details of products compatible with overseas standards. Body ported Base mounted Fluid Operating pressure range
More informationSeries VP3145/3165/3185
Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes
More informationD-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector
Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),
More informationPilot Operated 2 Port Solenoid Valve for Dry Air
Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible
More informationVacuum / Release Unit
Rubber Seal Vacuum / Release Unit Series VQD1000-V Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area Smooth detachment of a work piece without over-blow
More informationPilot Operated 2 Port Solenoid Valve for Dry Air
Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0
More information13 msec (at 500 mm )/18.5 msec (at 1000 mm )
Vacuum / Release Unit Series VQD1000-V Rubber Seal Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area [Option] Smooth detachment of a work piece without
More informationPower Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.
Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control
More information3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option
3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity
More informationSeries SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510
Vacuum Release Valve with Restrictor Series SJ3A6 SJ Plug-in Type Connector Connection P.86 D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Non Plug-in Type Individual
More informationSeries VP3145/3165/3185
Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to
More informationFluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single
Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position
More informationBody width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.
High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure of 0.5MPa, subject to clean, dry air) 4 Port Direct
More information5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure
For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Series 000 Compact and lightweight: 3 mm width Compact yet provides
More information3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot
3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in
More information5 Port Solenoid Valve
5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry
More informationHow to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.
Series -S00 ompact Direct Operated Port Solenoid Valve ontrol Valves ase mounted ody ported lean Series lean Series V S R oil voltage 24 VD VD VD VD VD Power consumption Pressure specification Flow rate
More information3 Port Solenoid Valve
3 ort Solenoid Valve Series VKF300 ubber Seal Direct Operated oppet Type Compact yet provides a large flow capacity Body width 8 mm vailable in vacuum applications ( 0. ka) Can be used in vacuum/release
More informationSeries VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non
Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non
More information3 Port 3 Position Valve
Port Position Valve Pilot Solenoid ir Operated ohs Intermediate stopping of cylinders * up to ø15 is possible. Pilot solenoid Manifold ir operated * For VEX 4, 00 mm/s, horizontal movement Power consumption:
More informationSeries SY3000/5000/7000
Type20P 5 Port Solenoid Valve ody Ported Manifold ar Stock Type/Flat Ribbon Cable Series SY3000/5000/7000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 5 20P 05 Manifold series 3 SY3000
More information3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.
Port Solenoid Valve Series VQ 00 Unprecedented high speed, stable response, and extra-long service life. ON:.ms, OFF: ms, Dispension accuracy ±ms (With indicator light and surge voltage suppressor; supply
More information3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum
3 Port Direct Operated Poppet Rubber Seal Series 307 Large Flow Capacity, yet Compact Size. Dimensions (W X H X D) 30 X 54.5 X 33 307 Nl/min 206.02 or more, 1/4 Low Power Consumption /VO307 4.8W DC/Standard
More informationSeries SYA3000/5000/7000
Port Air Operated Valve Series SYA000/000/7000 How to Order A, B port size Thread type Thread piping (Inch size) Nil Rc Symbol Port size Applicable series Symbol Port size Applicable series F G M SYA000
More information(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC
5 Port Pilot Operated Solenoid Valve Metal Seal Series VZS Series Variations Plug-in Type Base Mounted Type (With sub-plate) Non Plug-in Type Base Mounted Type (With sub-plate) Series Sonic conductance
More informationRubber Seal VP300/500/700
Port Pilot Operated Poppet Rubber Seal 00/500/700 High flow capacity Cv1.0 (00), Cv. (500), Cv.0 (700) Low power consumption: 1.8W(DC) Possible to use as either selector valve or divider valve Changeable
More information3 Port Solenoid Valve
Rubber Seal Port Solenoid Valve Series Manifold Single Unit ase Mounted Manifold VV01 V100 ar base P.18 ody Ported P.10 ase Mounted P.10 VQD VKF VK VT VS Separable base ody Ported Manifold P.1 Stacking
More informationFlow characteristics Max. (1) b Standard Specifications. P Manual override.
Port Direct Operated Solenoid Valve Series 0 Metal Seal Model Number of positions (Single) (Double) ( position) JIS Symbol Model Port size Rc (Nominal size) 0-0 8 ( A) 0- ( 8A) 0-0 8 (0A) 0-0 8 ( A) 0-
More informationSeries SV1000/2000/3000/4000
Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double
More information2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating
/ ort Solenoid Valve ubber Seal Series SYJ000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Specifications JIS Symbol port port (manifold) position
More informationHow to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1
Port Solenoid Valve Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Non plug-in manifold 0 0 S 60 Stations stations 0 stations SUP/EXH
More informationSeries SYA3000/5000/7000
Port Air Operated Valve Series SYA000/000/7000 How to Order A, B port size Thread type Thread piping (Inch size) Nil Rc Symbol Port size Applicable series Symbol Port size Applicable series F G M SYA000
More information4 Port Solenoid Valve Cassette Type Manifold Rubber Seal
Port Solenoid Valve Cassette Type Manifold Rubber Seal 7.mm (SJ000) SJ000 SJ000 Can be mounted together. 0mm (SJ000) Connector connection New New cable type manifold is added! New Additional options are
More information5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range
For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR2 JIS Symbol type
More informationATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry
Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 044 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000 racket
More informationS Y 3 A F NFZD
SY3000 IFM Serie SY HOW TO ORDER - VALVES S Y 3 A 0 0 5 F NFZD Series 3 SY3000 Type of actuation Manual override D: Push-turn locking type A Rated voltage 5 24VDC SPECIFICATION Fluid Air Operating pressure
More informationSeries SYA3000/5000/7000
1 Port Air Operated Valve Series SYA000/000/7000 Body ported Base mounted Base mounted How to Order A, B port size Thread type Thread piping (Inch size) Nil Rc Symbol Port size Applicable series Symbol
More information1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption
Port Solenoid Valve Direct Operated Poppet Type Power consumption Vacuum applications New [Option] RoHS 4 Standard wtype (Existing product: 4.8 W) 0. kpa Energy-saving type.8 w (Existing product: W) A
More informationSeries ZM Applications
Ejector Series ZM All in One! Built-in suction filter and silencer Air supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)
More informationATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry
TEX Compliant Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 44 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000
More informationGrommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC
5 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Body Ported Base Mounted Series S000 S000 S000 S000 S000 S4000 S5000 Sonic conductance C [dm /s bar)] 4/ 5/(A/B R/R) Single Double.8.4
More information10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection
Rubber Seal Port Solenoid Valve Series SJ000/000 Cassette Type Manifold 0 mm 7. mm (SJ000) 0 mm (SJ000) Non plug-in type Individual wiring manifold SJ000 SJ000 Can be mounted together. Connecter connection
More information5 Port Solenoid Valve Plug Lead Type
5 Port Solenoid alve Plug Lead Type Series Body Ported Flow rate characteristics For single/double solenoid C [dm 3 /(s bar)]: 0.6 Single Unit alve width: 7.4 mm Possible to drive cylinders: Up to ø32
More informationSeries SYA3000/5000/7000
Port Air Operated Valve Series SYA000/000/7000 How to Order A, B port size Thread type Thread piping (Inch size) - Rc Symbol Port size Applicable series Symbol Port size Applicable series F G SYA000 N
More informationNew Concept Connector Type Manifold
New Concept Connector Type Manifold Series /000/3000/000 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration.
More informationPower Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.
Power Valve: Regulator Valve Series 1 Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control
More informationHow to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications
For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector
More informationHow to Order Manifold. Option Symbol
Series Plug Lead nit For details about certified products conforming to international standards, visit us at www.smcworld.com. Series/Manifold 12 Stations 01 1 station Kit/Electrical entry/cable length
More informationBase Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer
Base Mounted Metal Seal/Rubber Seal VQ Built-in silencer, direct exhaust Space-saving profile All pilot valves are compactly mounted on one side. The space-saving design of mounting all fittings on one
More information0.35 W (Without light)
Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:
More informationVacuum Release Valve with Restrictor
INFORMATION Series SY3/5 Plug-in Only for External Pilot Vacuum Release Valve with Vacuum suction and release can be controlled with a single valve! PE Pilot EH port Flow rate adjustment of release air
More informationEjector Valve Unit Series ZYY/ZYX
Ejector Valve Unit Series ZYY/ZYX Series ZYY3 (Solenoid valve: SY3) Nozzle diameter: ø.7, ø1. Type S: Standard type L: Large flow type Ejectors and solenoid valves can be mounted on the same manifold.
More informationSeries SY3000/5000/7000
Type1P Type2P 5 Port Solenoid Valve ase Mounted Manifold ar Stock Type/Flat Ribbon Cable Series /5000/000 How to Order Manifold Type 1P/Compact style SS5Y 5 1P 05 C8 Manifold series 3 5, port size Thread
More information5 Port Air Operated Valve
Port ir Operated Valve Series VF000/000/000 RoHS 22- Series VF000/000/000 Model Selection by Operating Conditions q ir Operated Valve: Single Unit Series Sonic conductance C[dm /(s bar)] Type of actuation
More informationExample. U side. Stations SY5000
45 Type 5 ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN ail Mounted/Individual Wiring Series SY3000/5000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 3 45 05 U C6 Example
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position
More informationManifold Specifications
Series 00 Manifold Specifications Manifold Specifications Model Manifold type P(SUP)/R(EXH) Valve stations A port porting specifications Port size For internal pilot For external pilot Location Direction
More informationVacuum Ejector. Series ZM
Ejector Series All in One! Built-in suction filter and silencer Air supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)
More informationSeries ZM Applications
Ejector [Option] ll in One! Built-in suction filter and silencer ir supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)
More information4/5 Port Solenoid Valve
CT.ES8 / ort Solenoid Valve Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M.7 to M2. 앬 Flow Characteristics Series Cover (stainless
More informationIndicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A
1 3 Port Air Operated Valve Series VTA301 JIS Symbol VTA 301 Indicate VO for manifold. Port size Specifications How to Order Without connection port (For manifold) 01 1/8 02 1/4 Option Fluid Air Operating
More information4/5 Port Solenoid Valve
ubber Seal / ort Solenoid Valve Series 000 / 000 / 000 [Option] SJ SY SV SZ V S000 VQ VQ VQ VQC VQZ SQ VFS VF VQ Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread
More informationOption. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications
Series -SQ00 Port Solenoid Valve Plug-in Unit [Option] How to Order Manifold Electrical entry F kit D-sub connector kit P kit SSQ 08 FD Kit type Flat ribbon cable connector kit J kit Flat ribbon cable
More informationSeries VQZ1000/2000/3000 Single Unit
+- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body
More information5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted
Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted
More informationQ1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.
Multistage Ejector 112/212 Series Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3
More information5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC)
Port Solenoid Valve/Direct Poppet Rubber seal Series VK3000 Nl/min 147 Compact/Width 18 X Length 8 (mm) Low power consumption 4W DC (Standard) 2W DC (Energy saver) Standard copper free specification All
More information5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles
ort Solenoid Valve: ase Mounted Metal Seal/Rubber Seal Series Space and capacity saving ilot valve is gathered at one side. Space saving design which does not have any protrusions. Space saving Capacity
More information3MA0/3MB0. Small pneumatic valve. 3 port direct acting valve CONTENTS. Space saving Valves are compactly designed with widths of 10 mm
M0/MB0 Small pneumatic valve M Overview The M0 and MB0 Series port valve is a 0 mm wide miniature direct-acting poppet valve compatible with system downsizing. variety of types, including discrete and
More informationSeries ZM Applications
Ejector [Option] ll in One! Built-in suction filter and silencer ir supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)
More informationVacuum Equipment. Application. Series
Equipment Series Application Page ejector In-line vacuum ejector Multistage ejector ejector with check valve Pad with check valve ejector for water soluble coolant removal ZH ZU ZL1/2 (Special order product)
More information5 Port Solenoid Valve
Metal seal Port Solenoid Valve Series VQ Rubber Seal Space-saving profile Clean space saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less
More information