10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

Size: px
Start display at page:

Download "10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry"

Transcription

1 Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available only with DCW type. Function H Y N U Note) Standard (W) High pressure type (.W) ow wattage type (0.W) atching type Positive common atching type Negative common arge flow type : Option Note) Except latching and large flow types. Use a low wattage type when operated under continuous energization. Coil rated voltage 00 VC (0/60Hz) 00 VC (0/60Hz) 0 VC (0/60Hz) 0 VC (0/60Hz) VDC 6 VDC 9 Other special voltages For the special voltages, please consult with SMC. Port size M M Without sub-plate With sub-plate With sub-plate Non-locking push type (Tool required) atching type: Push-locking type (Tool required) B ocking type (Tool required) : Option Note) atching manual override: Push-locking type only. F O M Plug-in With light/surge voltage suppressor (Only for plug-in manifold) plug connector, with lead wire With light/surge voltage suppressor plug connector, without connector With light/surge voltage suppressor M plug connector, with lead wire With light/surge voltage suppressor Rotary actuator ir gripper Directional control valve Clean gas filter Flow control Filter, Pressure control Fittings & Tubing Pressure switch MO G M plug connector, without connector With light/surge voltage suppressor Grommet plug connector Note) Grommet: No latching, C and large flow types ir preparation M plug connector Grommet 0

2 Standard specifications JIS Symbol () (P)(R) Normally closed () (P)(R) Normally open () (P)(R) atching type Item Valve specifications Electrical specification Type Valve construction Fluid Maximum operating pressure Minimum operating pressure (vacuum) C[dm /(s bar)] b Flow Cv characteristics C[dm /(s bar)] b Cv Note ) Response time mbient and fluid temperature ubrication Mounting orientation Note ) Shock/Vibration resistance Enclosure Weight Coil rated voltage DC llowable voltage fluctuation Coil insulation type Power consumption (Current) DC Standard type ( W) High pressure type (. W) ow wattage type (0. W) port direct operated poppet ir / Inert gas 0.MPa 0.8MPa 0.MPa Note ) 0 MPa ( 00 kpa ) ON:.ms, OFF: ms ON:.ms, OFF:.ms Note ) 0 to 0 C Not required Note ) Non-locking push type / ocking type (tool required) Unrestricted 0/0 m/s Dust tight.6g (, M plug connector, Without sub-plate) V, V ±0% of rated voltage Equivalent to class B W ( m). W (6 m) 0. W ( m) Grommet Plug-in, plug connector, M plug connector (With light/surge voltage suppresser) Note ) Based on JIS B8-99. With light/surge voltage suppressor (clean air). Dispersion accuracy of ±ms Note ) Use dry air to prevent condensation when operating at low temperatures. Note ) ocking style: Option. Note ) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the right angles to the armature in both energized and deenergized states every once for each condition. (Initial value) Vibration resistance: No malfunction occurred in one sweep between and 000Hz. Test was performed in the axial direction and at the right angles to the armature in both energized and de-energized states. (Initial value) Note ) In vacuum applications, (R) port vacuum and (P) port vacuum release pressure can be used. (Differential pressure between (P) and (P) is up to the maximum operating pressure for each type.) 06

3 Option Valve specifications Electrical specification Item Type atching type C type arge flow type Normally open Model 0-VQ0-0-VQ0-0-VQ0U- 0-VQ0- Maximum operating pressure 0.MPa 0.6 MPa 0. MPa Minimum operating pressure Note ) 0 MPa ( 00 kpa) Note ) C[dm /(s bar)] Note 6) b Flow ( ) Cv characteristics C[dm /(s bar)] Note 6) b ( ) Cv Note ) Response time VDC ms or less W ( m) ms or less ms or less Note ) 0. W (9 m) ms or less W ( m) Note ) VDC W (8 m) 0. W (8 m) W (8 m) Power 00 VC 0.6 V (6 m) 0. V ( m) consumption 0 VC 0.6 V (.9 m) 0. V ( m) (Current) 00 VC. V (6 m).0 V ( m) 0 VC. V (.9m). V ( m) Note ) Plug-in, plug connector, M plug connector (With light/surge voltage suppresser) Note ) Note ) ir cylinder Rotary actuator ir gripper Directional control valve Dimensions Grommet 0-VQ 0 - G -M(M) Note ) Grommet is available only for normally open type (without light/surge voltage suppressor). Note ) Based on JIS B 8-99, With light/surge voltage suppressor (clean air) Note ) Starting. W (0 ms after energization), Holding 0. W. Note ) In vacuum applications, (R) port vacuum and (P) port vacuum release pressure can be used. (Differential pressure between (P) and (P) is up to the maximum operating pressure for each type.) Note ) In the case of (P) port vacuum and (R) port vacuum release, use VQ0 (normally open type). Note 6) ( ) denote the air passage for normally open type. Note ) Normally open type is available only with DCW specification Flow control Filter, Pressure control -ø. mounting hole..8 E. 8. ocking type manual override 0. pprox. 00 (ead wire length) Fittings & Tubing ir preparation Pressure switch (.) 8 9. (8.) (.9) -M, (M) P (.9) ( ): M Broken line: ocking type manual override. Clean gas filter 0

4 Dimensions plug connector 0-VQ 0 - -M(M) ead wire color: Black ead wire color: Red atching, C arge flow type -ø. Mounting hole E ocking type manual override 0.. pprox. 00 (ead wire length) 6. (.) -M,(M) 9. P ( ): M Broken line: atching, C and large flow Dashed line: ocking type manual override and push-locking type manual override (latching). = 00 (ead wire length) = 00 (ead wire length) atching, C arge flow type -ø. Mounting hole E ocking type manual override 0.. (.9) (.9) (0) M plug connector 0-VQ 0- M -M(M) (.) P -M,(M) 9. (.) (.9) (.9) ( ): M Broken line: atching, C and large flow Dashed line: ocking type manual override and push-locking type manual override (latching). 08

5 How to Order Manifold Plug-in unit Manifold pplicable solenoid valve (Plug-in type) 0-VQ 0 - F 0 VVQ 08 C U D Clean series Series VQ00 When mounting a latching type, please consult with SMC. Possible to mount U (large flow) type. Manifold base model no. Plug-in unit Note) Normally closed and normally open styles cannot be mounted on the same manifold. VVQ00-0- C Stations 0 stations 8 8 stations Multi-connector type U S Top entry Side entry How to Order Manifold ssembly Specify the part numbers for valves and options together beneath the manifold base part number. <Example> Plug-in unit manifold with cable ( m) 0-VVQ-0CU set Manifold Base part no. 0-VQ0-F sets Valve part no. (st to th station) VVQ00-0- set Blanking plate Part no. (th station) Prefix the asterisk to the part nos. of the solenoid valve, etc. m Enter in order starting from the first station on the D side. U side D side Stations ir cylinder Rotary actuator ir gripper Directional control valve 0 Cable length Without cable With cable (. m) With cable ( m) With cable ( m) Flow control D Note ) DO Option None DIN rail mounted (With standard length of DIN rail) DIN rail mounted (Without DIN rail) Note ) Order DIN rail separately. For DIN rail model number, refer to page. Filter, Pressure control How to Order Valves Clean series 0 VQ 0 F Series VQ Compact port valve Type of actuation Note) H Y U Note) Normally closed Normally open Note) Normally open type is available only with standard type. ( W) Function Standard type (W) High pressure type (.W) ow wattage type(0.w) arge flow type : Option Note) Except large flow type. Use a low wattage type when operated under continuous energization. B : Option Coil rated voltage 6 9 F Non-locking push type (tool required) ocking type (tool required) Plug-in With light/surge voltage suppresser (Only for plug-in manifold) 00 VC (0/60Hz) 00 VC (0/60Hz) 0 VC (0/60Hz) 0 VC (0/60Hz) VDC VDC Other special voltages For the special voltages, please consult with SMC. Fittings & Tubing ir preparation Pressure switch Clean gas filter 09

6 Plug-in unit (0-VVQ) Manifold with multi-connector The broken line indicates DIN rail mounted style (-D) and side entry connection (S). (8.) Plug assembly VVQ ø. mounting hole () () ().. (.) () () (9.) R (Min. bending inner radius) pprox. 0. D side Stations n U side -M x 0.8 (E port) -M x 0.8 (P port).. 0 n-m x 0.8 ( port) 8 P=0 (.) (8.) Dimensions n () () () Formula: = 0n + = 0n + n: Stations (Max. 8 stations)

7 How to Order Manifold How to Order Valve Manifold ssembly Plug lead unit Manifold 0 VVQ 08 0N Clean series pplicable solenoid valve (Plug lead type) 0-VQ 0 - Series VQ00 0-VQ 0 - M 0-VQ 0 - G Manifold base model no. Plug lead unit Plug lead unit Note) Normally closed and U normally open styles Type U (large flow) mounting base cannot be mounted on the same manifold. Stations VVQ stations 0 0 stations Specify the part numbers for valves and options together beneath the manifold base part number. <Example> Plug lead unit manifold 0-VVQ-0 set Manifold base part no. 0-VQ0- sets Valve part no. (st to th stations) VVQ00-0- set Blanking plate part no. (th station) Prefix the asterisk to the part nos. of the solenoid valve, etc. U side Station Enter in order starting from the first station on the D side. D side ir cylinder Rotary actuator ir gripper How to Order Valves Port size and thread 0N 0T 0F M, Rc/8 NPT/8 NPTF/8 PF/8 Only thread port size /8 (U type, P, E ports) has choice of thread. Directional control valve Flow control Clean series 0 VQ 0 Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available only with standard type. ( W) H Y N U Note) Function Standard type (W) High pressure type (.W) ow wattage type(0.w) atching Positive common atching Negative common arge flow type : Option Note) Except latching and large flow types. Use a low wattage type when operated under continuous energization. Coil rated voltage VC (0/60Hz) 00 VC (0/60Hz) 0 VC (0/60Hz) 0 VC (0/60Hz) VDC VDC Other special voltages For the special voltages, please consult with SMC. Non-locking push type (tool required) atching type: Push-locking type (tool required) B ocking type (tool required) : Option Note) atching manual override: Push-locking type only. plug connector, With lead wire With light/surge voltage suppresser O M MO G plug connector, Without connector With light/surge voltage suppresser M plug connector, With lead wire With light/surge voltage suppresser M plug connector, Without connector With light/surge voltage suppresser Grommet Note) Grommet: No latching, C and large flow types Filter, Pressure control Fittings & Tubing ir preparation Pressure switch Clean gas filter

8 Plug lead unit manifold (0-VVQ). -ø. Mounting hole U side E P n P=0. E P 8.9 D side 6. =00 (ead wire length) =00 (ead wire length) Round head combination screw M. x =00 (ead wire length) -M P, E ports =00 9 (ead wire length) For latching and C atching 00 VC or more Type W.. H.. Type M W H.. Dimensions n n-m port Formula: = 0n +, = 0n +, n: Stations (Max. 0 stations) Plug lead unit, Type U (large flow) mounted manifold (0-VVQU) Manual override Round head combination screw M. x 9 6 P P. -ø. Mounting hole E P=0. E.8 pprox. 00 -PT/8 P, E ports U side n D side pprox n-m x 0.8 port P=0 6. Dimensions n Formula: = 0n +, = 0n +, n: Stations (Max. 0 stations)

9 Manifold option Plug assembly VVQ Plug ø Female contact Vinyl multi-core cable Cable length Part no. VVQ00-- VVQ00-- VVQ00-- () () dimension. m m m Finishing O.D.ø.8 () 0 0 RP-PS-0SC <Made by Hirose Electric Co., td.> RP9-SC- <Made by Hirose Electric Co., td.> VVRF 0.mm 0 core Cover color: Ivory VVQ For manifold with multi-connector <D side end plate assembly> D side end plate assembly part no. VVQ00-- Option Standard type DIN rail mounting type <U side end plate assembly> U side end plate assembly part no. VVQ00-- Option Standard type DIN rail mounting type <DIN rail mounting bracket assembly> DIN rail mounting bracket assembly part no. XT80-- D U Mounting direction D side mounting U side mounting ir cylinder Rotary actuator ir gripper Directional control valve Blanking plate assembly VVQ00-0- Plug-in unit (VVQ) for manifold with multiple connectors Blanking plate with screws and gasket Note) The number of manifold stations cannot be changed. How to Order Only DIN Rail DIN rail part no.: XT00-DR- Refer to DIN rail dimension table below and put number into to order DIN rail. Refer to the manifold dimensions on page 0 to determine dimension.. (Pitch)... Flow control Filter, Pressure control Fittings & Tubing VVQ00-0- Plug lead unit (VVQ) for manifold Blanking plate with screws and gasket dimensions Pressure switch Clean gas filter No. dimension No. dimension No. dimension No. dimension =.n ir preparation

10 // Port Solenoid Valve Common Precautions Be sure to read before handling. Refer to the main text for detailed precautions on every series. Warning Caution on design. ctuator drive When an actuator, such as a cylinder, is to be driven using a valve, take appropriate measures to prevent potential danger caused by actuator operation.. Intermediate stop In the case of position closed center or perfect valve style, it is difficult to make an intermediate stop at the required position accurately and precisely due to compressibility of air. Furthermore, since valves and cylinders are not guaranteed for zero air leakage, it may not be possible to hold a stopped position for an extended period of time. Consult SMC if it is necessary to hold a stopped position for an extended period of time.. Effect of back pressure when using a manifold Use caution when valves are used on a manifold, as actuator may malfunction due to back-pressure. In the case of position closed exhaust center valve or single acting cylinder, take appropriate measures to prevent the malfunction using an individual EXH interface assembly or individual exhaust manifold.. Holding of pressure (including vacuum) Since valves are subject to air leakage, they cannot be used for applications such as holding pressure (including vacuum) in a pressure vessel.. Cannot be used as an emergency shut-off valve. The valves presented in this catalog are not designed for safety applications such as an emergency shut-off valve. If the valves are used in this type of system, other reliable safety assurance measures should also be adopted. 6. Maintenance space The installation should allow sufficient space for maintenance activities.. Release of residual pressure Install a system for releasing of residual pressure for maintenance purpose. Especially in the case of position closed center valve or double check valve, ensure the release of residual pressure between valve and cylinder. 8. Vacuum applications When valves are used for vacuum switching, etc., take measures to prevent suction of external dust or other contaminants that may lead to valve malfunction. Direct operated or external pilot operated style is recommended for this application. Please contact SMC if necessary to use internal pilot operated or air operated style. Warning Selection. Confirm the specifications. The products presented in this catalog are designed only for use in compressed air systems (including vacuum). Do not operate at pressures or temperatures, etc., beyond the range of specifications, as this can cause damage or malfunction. (Refer to specifications.) Contact SMC when using fluid other than compressed air (including vacuum).. Extended periods of continuous energization Contact SMC if valves will be continuously energized for a long period of time. Caution. Momentary energization If a double solenoid valve will be operated with momentary energization, it should be energized for at least 0. second.. eakage voltage When C-R device (surge voltage suppressor) is used for the protection of switching device, note that voltage leakage will be increased by passing voltage leakage through C-R device. Residual voltage leakage should not exceed the following values. DC coil SZ/SY/SYJ: % or less of rated voltage SQ/VQ/VQZ/VQD: % or less of rated voltage C coil SQ:.% or less of rated voltage SZ/SY/SYJ: 8% or less of rated voltage VQ/VQZ/VQD: % or less of rated voltage Switching element OFF C-R element eakage current. Use in low temperature environments Unless otherwise specified, valve can be used to temperature extremes to 0 C. However, appropriate measures should be taken to avoid freezing, drainage or condensation.. Operation for air blowing When using a solenoid valve for air blow, use an external pilot type or direct solenoid operated type. lso, supply compressed air within the pressure range specified in the specifications to the external pilot port.. Mounting orientation Rubber seal: Refer to the specifications of each series. Metal seal: Mounting orientation of single solenoid is universal. When installing double solenoid or position style, mount the valve so that spool valve will be horizontal. Power supply eakage voltage Valve

11 // port solenoid valve Common precautions Be sure to read before handling. Refer to the main text for detailed precautions on every series. Warning Mounting. If air leakage increases or does not operate properly, stop operation. Check mounting conditions when air and power supplies are connected. Function and leakage tests should be performed after installation.. Instruction manuals Install the products and operate them only after reading the instruction manual carefully and understanding its contents. lso keep the manual where it can be referred to as necessary.. Painting and coating Warnings or specifications printed on or affixed to the products should not be erased, removed or covered up. Please consult with SMC if paint is to be applied to resin parts, as this may have an adverse effect due to the paint solvent... Piping Caution When closed center and double check valve are used. When a closed center and perfect valve are used, check the piping to prevent air leakage from the piping between valve and cylinder. Strictly observe the specified tightening torque. When installing fittings onto a valve, tighten with the proper tightening torque shown below. Tightening torque Connection thread M M Rc/8 Rc/ Rc/8 Rc/ Rc/ Rc Rc/ Rc/ Rc ppropriate tightening torque N m 0. to 0.. to to 9 to to 8 to 0 8 to 0 6 to 8 0 to 8 to 0 8 to 0. Piping to products When piping to a product, refer to the instruction manual to avoid mistakes regarding the supply port, etc. Caution Wiring. Polarity When connecting power to a DC specification solenoid valve equipped with light/surge voltage suppressor, check for polarity. If there is polarity, take note of the following points. Without diode to protect polarity: If a mistake is made regarding polarity, the diode in the valve, the control device switching element or power supply, etc. may burn out. With diode to protect polarity: If polarity connection is wrong, the valve does not switch... pplied voltage When electric power is connected to a solenoid valve, be careful to apply the proper voltage. Improper voltage may cause malfunction or coil damage. Confirmation of connections fter completing the wiring, confirm that the connections are correct. ir cylinder Rotary actuator ir gripper Directional control valve Fittings & Tubing Pressure switch Clean gas filter Flow control Filter, Pressure control ir preparation

12 // Port Solenoid Valve Common Precautions Be sure to read before handling. Refer to the main text for detailed precautions on every series. Warning ir Supply. Use clean air. Do not use compressed air which contains chemicals, salt or corrosive gases, etc. as this can cause damage or malfunction. Caution. Install air filters. Install air filter close to valves at their inlet side. filtration degree of the filter should be µm or less.. Install an aftercooler, air dryer or water separator (drain catch), etc. ir that includes excessive drainage may cause malfunction of valves and other pneumatic. To prevent this, install an air dryer, aftercooler or water separator, etc.. When a large amount of carbon dust is generated, install a mist separator on the inlet side of the valve to eliminate dust. When a large amount of carbon dust is generated from the compressor, it may attach to the inside of the valve, which may cause malfunction. Warning Operating environment. Do not use in atmospheres where the valve is in direct contact with corrosive gases or chemicals.. Do not use in explosive atmosphere.. Do not use in a place subject to heavy vibrations and/or shocks. Check the specifications for each series.. Install a protection cover if the product is exposed to direct sunlight.. Remove the emissive heat when there is a source of heat around the product. 6. When the solenoid valve is mounted in a control panel or is energized for a long time, make sure that ambient temperature is within the valve specification range. Warning Maintenance. Perform maintenance procedures as shown in the instruction manual. If it is handled improperly, malfunction or damage of machinery or may occur.. Removal of, and supply/exhaust of compressed air Before detaching the, first confirm that measures are in place to prevent dropping of workpieces and run-away of, etc. Then cut the supply pressure and power, and exhaust all compressed air from the system using its residual pressure release function. In the case of position closed center or perfect valve style, exhaust the residual pressure between valve and cylinder. When the is started again after remounting or replacement, first confirm that measures are in place to prevent lurching of actuators, etc. and then confirm that the is operating normally.. ow frequency operation Valves should be switched at least once every 0 days to avoid malfunctions. (Use caution regarding the air supply.). operation When the manual override is operated, connected will be actuated. Confirm safety before operation. Caution. Drain flushing Remove drainage from air filters regularly. Maintenance When placing an order of optional part separately, the part is not double packed if its part no. does not include a prefix of "0-". When such part is brought into a clean room, give flushing to the part with highly purified air to remove dust attached to the valve surface completely. When replacing or mounting a valve (including pilot valve) or an optional part, be sure to tighten it with the specified tightening torque and make sure that no leakage occurs. In the case of external pilot When an external pilot solenoid valve is used, air is exhausted also from PE port (pilot exhaust). Therefore, such air should be exhausted to the outside of cleanroom. (If the port is plugged, it may cause malfunction.) 6

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is. Port Solenoid Valve Series VQ 00 Unprecedented high speed, stable response, and extra-long service life. ON:.ms, OFF: ms, Dispension accuracy ±ms (With indicator light and surge voltage suppressor; supply

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Soft Start-up Valve. AV2000/3000/4000/5000 Series Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector

More information

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S. High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure of 0.5MPa, subject to clean, dry air) 4 Port Direct

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm 4 Port Direct Operated Poppet Solenoid Valve Series D1000 High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Series VQ Rubber Seal Space-saving profile Clean space saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

Vacuum / Release Unit

Vacuum / Release Unit Rubber Seal Vacuum / Release Unit Series VQD1000-V Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area Smooth detachment of a work piece without over-blow

More information

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type. Series -S00 ompact Direct Operated Port Solenoid Valve ontrol Valves ase mounted ody ported lean Series lean Series V S R oil voltage 24 VD VD VD VD VD Power consumption Pressure specification Flow rate

More information

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing

More information

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Vacuum / Release Unit Series VQD1000-V Rubber Seal Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area [Option] Smooth detachment of a work piece without

More information

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

Series AV2000/3000/4000/5000

Series AV2000/3000/4000/5000 Soft Start-up Valve Series AV/3/4/5 Series introduced! A start-up valve that gradually increases supply pressure during start up and rapidly exhausts system air when the supply air is shut off AC AV AU

More information

Series VQZ1000/2000/3000 Single Unit

Series VQZ1000/2000/3000 Single Unit +- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body

More information

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal

More information

0.35 W (Without light)

0.35 W (Without light) Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot ubber seal ort ilot Solenoid Valve Series SYJ00 Specifications efer to www.smcworld.com for details of products compatible with overseas standards. Body ported Base mounted Fluid Operating pressure range

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry

More information

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications Series -SQ00 Port Solenoid Valve Plug-in Unit [Option] How to Order Manifold Electrical entry F kit D-sub connector kit P kit SSQ 08 FD Kit type Flat ribbon cable connector kit J kit Flat ribbon cable

More information

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot 3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in

More information

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000) 5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M. V3 Cover

More information

3 Port Air Operated Valve

3 Port Air Operated Valve Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation

More information

3/4/5-Port Solenoid Valves Precautions 1 Be sure to read this before handling products.

3/4/5-Port Solenoid Valves Precautions 1 Be sure to read this before handling products. Precautions 1 1. Confirm the specifications. Products represented in this catalog are designed only for use in compressed air systems (including vacuum). Do not operate at pressures, temperatures, etc.,

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

VQ1000. How to Order Manifold. Kit type

VQ1000. How to Order Manifold. Kit type - - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold

More information

KV series. Innovatively detachable Manifold Block. Smart Solenoid Valve (plug-in type, D-SUB multi-connector type)

KV series. Innovatively detachable Manifold Block. Smart Solenoid Valve (plug-in type, D-SUB multi-connector type) CAT.1101E-S www.sym1.com KV series Innovatively detachable Manifold Block (DIN Rail Mounting) Smart Solenoid Valve (Plug-in type, D-SUB multi-connector ) Compact size with large flow capacity Exceedingly

More information

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Series 000 Compact and lightweight: 3 mm width Compact yet provides

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes

More information

Series SV1000/2000/3000/4000

Series SV1000/2000/3000/4000 Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high

More information

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I ISO Standard Solenoid Valve Series VQ7-6/7-8 (Size ) (Size ) Conforms to ISO Standard /I.0- Ideal for driving cylinders up to Large flow capacity ø00 (VQ7-6, Size ) ø60 (VQ7-8, Size ) Nl/min VQ7-6: 668.

More information

Two Hand Control Valve

Two Hand Control Valve Two Hand Control Valve Series n output is available through synchronized, twohanded operation (within 0.5 s)! Conforming to EN574 RoHS (Interchangeable with XT92-67 ) Example of a basic circuit diagram

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Rubber Seal Series VQ Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

NAMUR Interface 5 Port Solenoid Valve

NAMUR Interface 5 Port Solenoid Valve NAMUR Interface 5 Port Solenoid Valve Series VFN000N 5 5 Specifications Valve Electrical entry Fluid Max. operating pressure Min. operating pressure Ambient and fluid temperature Lubrication Pilot operator

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and

More information

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000

More information

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles ort Solenoid Valve: ase Mounted Metal Seal/Rubber Seal Series Space and capacity saving ilot valve is gathered at one side. Space saving design which does not have any protrusions. Space saving Capacity

More information

Rubber Seal VP300/500/700

Rubber Seal VP300/500/700 Port Pilot Operated Poppet Rubber Seal 00/500/700 High flow capacity Cv1.0 (00), Cv. (500), Cv.0 (700) Low power consumption: 1.8W(DC) Possible to use as either selector valve or divider valve Changeable

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 MPa Pilot Operated /3 Port Solenoid Valve & Check Valve VCH Series VCH4/4: Port VCH40: 3 Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve [Option] VCH40 Series Stable responsiveness Response

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Port Solenoid Valve Metal Seal Rubber Seal Series Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

5 Port Solenoid Valve Plug Lead Type

5 Port Solenoid Valve Plug Lead Type 5 Port Solenoid alve Plug Lead Type Series Body Ported Flow rate characteristics For single/double solenoid C [dm 3 /(s bar)]: 0.6 Single Unit alve width: 7.4 mm Possible to drive cylinders: Up to ø32

More information

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control Process Valve Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external pilot

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

5 Port Air Operated Valve

5 Port Air Operated Valve Port ir Operated Valve Series VF000/000/000 RoHS 22- Series VF000/000/000 Model Selection by Operating Conditions q ir Operated Valve: Single Unit Series Sonic conductance C[dm /(s bar)] Type of actuation

More information

Series SYA3000/5000/7000

Series SYA3000/5000/7000 Port Air Operated Valve Series SYA000/000/7000 How to Order A, B port size Thread type Thread piping (Inch size) - Rc Symbol Port size Applicable series Symbol Port size Applicable series F G SYA000 N

More information

Exclusively for air pressure system and air-hydro circuit control

Exclusively for air pressure system and air-hydro circuit control Process Valve Series Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external

More information

Manifold Specifications

Manifold Specifications Specifications Specifications Base mounted VVFR-01 VVFR- VVFR-0 Wiring With terminal block With multi-connector With D-sub connector Grommet terminal DIN terminal Grommet Grommet terminal Conduit terminal

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model 2 position 3 position

More information

How to Order Manifold. Kit type L8 B4 B6 B8 LM

How to Order Manifold. Kit type L8 B4 B6 B8 LM 0 Stations station VVQ Series VQ000 The maximum and minimum number of are varied depending on. (Refer to the table below.) Series VQ000 ase Mounted Plug-in Unit Manifold Plug-in unit 08 C Cylinder port

More information

Non-Contact Sensor for Workpiece Placement Verification

Non-Contact Sensor for Workpiece Placement Verification ir Catch Sensor Series 2 Non-Contact Sensor for Workpiece Placement Verification Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact

More information

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer Base Mounted Metal Seal/Rubber Seal VQ Built-in silencer, direct exhaust Space-saving profile All pilot valves are compactly mounted on one side. The space-saving design of mounting all fittings on one

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

High Pressure Coolant Valve

High Pressure Coolant Valve High Pressure Coolant Valve Series.5 MPa, 7.0 MPa Corresponding to high speed grinding and long drilling processes Coolant valve for high pressure coolant liquid (up to.5 MPa or 7.0 MPa) that is ideal

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR2 JIS Symbol type

More information

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle. Multistage Ejector 112/212 Series Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus

More information

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air Compact Direct Operated / Port Solenoid Valve for Water and Air 0/0/0: Port, 00/00: Port 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to

More information

3 Port Solenoid Valve

3 Port Solenoid Valve 3 ort Solenoid Valve Series VKF300 ubber Seal Direct Operated oppet Type Compact yet provides a large flow capacity Body width 8 mm vailable in vacuum applications ( 0. ka) Can be used in vacuum/release

More information

3 Port 3 Position Valve

3 Port 3 Position Valve Port Position Valve Pilot Solenoid ir Operated ohs Intermediate stopping of cylinders * up to ø15 is possible. Pilot solenoid Manifold ir operated * For VEX 4, 00 mm/s, horizontal movement Power consumption:

More information

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection Rubber Seal Port Solenoid Valve Series SJ000/000 Cassette Type Manifold 0 mm 7. mm (SJ000) 0 mm (SJ000) Non plug-in type Individual wiring manifold SJ000 SJ000 Can be mounted together. Connecter connection

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 044 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000 racket

More information

Series SYA3000/5000/7000

Series SYA3000/5000/7000 Port Air Operated Valve Series SYA000/000/7000 How to Order A, B port size Thread type Thread piping (Inch size) Nil Rc Symbol Port size Applicable series Symbol Port size Applicable series F G M SYA000

More information

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC)

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC) Port Solenoid Valve/Direct Poppet Rubber seal Series VK3000 Nl/min 147 Compact/Width 18 X Length 8 (mm) Low power consumption 4W DC (Standard) 2W DC (Energy saver) Standard copper free specification All

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry TEX Compliant Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 44 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Rubber Seal Port Solenoid Valve Series Manifold Single Unit ase Mounted Manifold VV01 V100 ar base P.18 ody Ported P.10 ase Mounted P.10 VQD VKF VK VT VS Separable base ody Ported Manifold P.1 Stacking

More information

Vacuum System Peripherals

Vacuum System Peripherals Vacuum System Peripherals Vacuum Regulator/Electronic Vacuum Regulator Vacuum regulator: IRV0/0 Electronic vacuum regulator: ITV009/ITV09 Directional Control Valve Selection guide of directional control

More information

Doc. No.VQ1000V-OMM0002-B. Solenoid Valve PRODUCT NAME. VQ1000/2000 Series (PILOT VALVE : V100) MODEL/ Series

Doc. No.VQ1000V-OMM0002-B. Solenoid Valve PRODUCT NAME. VQ1000/2000 Series (PILOT VALVE : V100) MODEL/ Series Doc. Solenoid Valve PRODUCT NAME VQ1000/2000 Series (PILOT VALVE : V100) MODEL/ Series Contents Safety Instructions ---------------------------------------------------------------------------- 2,3 Precautions

More information

1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption

1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption Port Solenoid Valve Direct Operated Poppet Type Power consumption Vacuum applications New [Option] RoHS 4 Standard wtype (Existing product: 4.8 W) 0. kpa Energy-saving type.8 w (Existing product: W) A

More information

Series SYA3000/5000/7000

Series SYA3000/5000/7000 Port Air Operated Valve Series SYA000/000/7000 How to Order A, B port size Thread type Thread piping (Inch size) Nil Rc Symbol Port size Applicable series Symbol Port size Applicable series F G M SYA000

More information

Series SYA3000/5000/7000

Series SYA3000/5000/7000 1 Port Air Operated Valve Series SYA000/000/7000 Body ported Base mounted Base mounted How to Order A, B port size Thread type Thread piping (Inch size) Nil Rc Symbol Port size Applicable series Symbol

More information

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve CT.E- ase Mounted Type Series VQ Port Metal Seal/Rubber Seal Solenoid Valve dvanced manifold va the new age of factory au ase Mounted Type Space saving profile Clean space saving design with all pilot