1 Port Solenoid Valve Metal Seal Rubber Seal Series Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less Capacity-saving % less (In-house comparison) Compact with large flow capacity (Ideal for driving cylinders up to ø) uilt-in One-touch fittings for easier piping Enclosure IP compliant Dusttight/Low jetproof type Cylinder Speed Chart Speed controller S- verage speed (mm/s) Series M, C Pressure. MPa Load rate: % Stroke mm Silencer N- Use as a guide for selection. Please confirm the actual conditions with Sizing Program. ore size Series CS Pressure. MPa Load rate: % Stroke mm ø ø ø ø ø ø ø ø ø ø SPG (Steel pipe) dia. x Length x m Outstanding response times and long service life (Metal seal with indicator light/surge suppressor) ms (Single) million cycles ms (Double) ccuracy ± ms ccording to life test conditions Perpendicular, upward actuation Horizontal actuation It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. Load factor:((load weight x.)/theoretical force) x % System Components variety of common wiring methods are standardized. <Plug-in type> kit kit F T (D-sub connector) (Terminal block box) P. P. L kit (Lead wire) P. Enclosure IP compatible C S kit (Connector) P. Enclosure IP compatible kit (Serial transmission) P. Enclosure IP compatible Individual wiring type <Plug lead type> Enclosure IP compatible Grommet type SJ SV J SZ VF VP S VQ VQ VQC VQC VQZ SQ VFS VFR VQ

2 ase Mounted Plug-in/Plug Lead Single Unit Model Series position Configuration Single Double Model Metal seal Rubber seal Metal seal Rubber seal Port size Closed Metal seal center Rubber seal Rc / Exhaust Metal seal center Rubber seal Pressure Metal seal center Rubber seal Double Metal seal check Rubber seal position Flow characteristics / (P /) / / (/ E/E) C [dm /(sbar)] b CV C [dm /(sbar)] b CV Standard W or less or less or less or less or less or less or less or less or less or less or less or less Response time (ms) Low wattage. W C or less or less or less or less or less or less or less or less or less or less or less or less or less or less or less or less or less or less or less or less or less or less or less or less Weight (kg). (.). (.). (.). (.). (.). (.) Note ) Value for valve on sub-plate and cylinder port Rc / Note ) ased on JIS - Supply pressure:. MPa, with indicator light and surge voltage suppressor, clean air. This will change depending on pressure and air quality.) The value when ON for the double type. Note ) Values inside ( ) indicate the weight of plug lead units. Table: Without sub-plate, With sub-plate: dd. kg for plug-in type,. kg for plug lead type. Symbol position single (R)(P)(R) position double (Metal) (R)(P) (R) (R)(P)(R) position double (Rubber) position pressure center (R)(P)(R) Plug-in unit Plug lead unit position closed center (R)(P)(R) position exhaust center (R)(P)(R) position double check Standard Specifications Valve specifications Solenoid specifications Valve construction Fluid Maximum operating pressure () Single Min. operating pressure Double position mbient and fluid temperature Lubrication Manual override Impact/Vibration resistance Enclosure Coil rated voltage llowable voltage fluctuation Coil insulation type VDC VDC Power consumption VC (Current) VC VC VC Metal seal Rubber seal ir ir. MPa (. MPa). MPa. MPa. MPa. MPa. MPa. MPa () () to C to C Not required Push type/locking type (Tool required) Option / m/s Dust tight (IP compatible), VDC,,,, VC (/ Hz) ±% of rated voltage Class or equivalent W DC ( m),. W DC ( m) W DC ( m),. W DC ( m) Inrush. V ( m), Holding. V ( m) Inrush. V (. m), Holding. V (. m) Inrush. V ( m), Holding. V ( m) Inrush. V (. m), Holding. V (. m) Note ) Use dry air to prevent condensation when operating at low temperatures. Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between and Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Note ) Values inside ( ) denote the low wattage (. W) specifications. C (R)(P)(R)

3 ase Mounted Plug-in/Plug Lead: Single Unit How to Order Valves [Option] Metal Rubber P S Plug-in Plug lead ody : Plug-in sub-plate Type of actuation position single position closed center Electrical entry Plug-in conduit terminal Plug lead Enclosure Dust-protected Note) W Dusttight /Low jetproof type Note) It is not necessary for plug lead type. (R)(P)(R) (R)(P)(R) position double position exhaust center (R)(P)(R) (R)(P)(R) position double position pressure center (R)(P)(R) (R)(P)(R) position double check Note) (R)(P)(R) Note) For double check style, refer to page. ody : Plug lead sub-plate How to Order Sub-plates Porting specifications Side ported ottom ported () Porting specifications Coil voltage Seal CE-compliant Q CE-compliant Port size Rc / Rc / Note ) For bottom ported port size is RC / only. Note ) For thread standard, refer to page. Side ported ottom ported Enclosure Dust-protected Dusttight/ W Low jetproof type (IP) Manual override : Non-locking push type (Tool required) Light/Surge voltage suppressor Yes E Without light, with surge voltage suppressor Electrical entry VC (/ Hz) VC (/ Hz) VC (/ Hz) VC (/ Hz) VDC VDC Metal seal Rubber seal [Option] Grommet Port size Without sub-plate (For manifold) G Lead wire length. m H Lead wire length. m Function Y () R () Rc / Rc / Note) For thread standard, refer to page. CE-compliant Q CE-compliant : Slotted locking type (Tool required) Standard type ( W) Low wattage type (. W) External pilot Note ) pplicable to DC specifications. Please select when you expect to energize the unit for extended periods of time. Refer to page for details. Note ) For external pilot specifications, refer to page. Combination of external pilot and perfect interface is not possible. Note ) When two or more symbols are specified, indicate them alphabetically. Replacement of pilot valve assembly (Voltage) Refer to pages and for pilot valve assembly part numbers. For How to Replace, refer to page. SJ SV J SZ VF VP S VQ VQ VQC VQC VQZ SQ VFS VFR VQ

4 . Conduit terminal Indicator light (.) (.) port () port... Plug-in Type position single: -. Manual override x ø. Mounting hole x ø... Mounting hole x Rc /,/ ((R), (R) port Rc /) ottom ported drawing PE X., () port. R P R... G / Electrical entry Rc / PE port. (). () Rc / External pilot port x Rc /, / (P),, (), (R), (R) port ( ): Rc / position double: - position closed center: - position exhaust center: - position pressure center: - Indicator light (.) port (.) () port. position double check: - Manual override (.) (.) port () port Indicator light. x ø. Mounting hole Manual override x ø. Mounting hole PE X. G / Electrical entry.. Rc / G / PE port Electrical entry R. () P. () R... Rc / External pilot port x Rc /, / (P),, (), (R), (R) port Rc / PE port R PE P X.. () () R... x Rc /, / (P),, (), (R), (R) port : position ( ): Rc /

5 Indicator light Indicator light Rc / PE port H... (.) (.) port () port R.... (.) port PE.. () () (.) () port P X R. x ø. Mounting hole.. x ø. Mounting hole.. Rc / External pilot port x Rc /, / (P),, (), (R), (R) port.... x ø. Mounting hole... x Rc /, / ((R), (R) port Rc /) ottom ported drawing... (.) (.) port () port Indicator light.. x ø. Mounting hole ase Mounted Plug-in/Plug Lead: Single Unit Plug Lead Type Grommet position single: G - Manual override position double: - G H position closed center: G - H position exhaust center: GH - position pressure center: - Manual override G H (, port) position double check: Manual override ( ): Rc / SJ SV J SZ VF VP S VQ VQ VQC VQC VQZ SQ VFS VFR VQ PE X PE X. R P R... R P R... Rc / PE port.. () () Rc / External pilot port x Rc /, / (P),, (), (R), (R) port Rc / PE port.. () () x Rc /, / (P),, (), (R), (R) port : position ( ): Rc /

6 ase Mounted Plug-in Unit [Option] How to Order Manifold VVQ Series Manifold Plug-in unit Stations station The maximum and minimum number of stations are varied depending on kit. (Refer to the table below.) Cylinder port C With One-touch fitting for ø C With One-touch fitting for ø C With One-touch fitting for ø C With One-touch fitting for ø Rc / Rc / ottom ported Rc / CM Mixed C F U K Thread type F T Rc G NPT/NPTF Kit type Control unit Refer to pages to. Kit/Electrical entry/cable length F kit (D-sub connector) Option Symbol CD () CU () K () N S SD () SU () W CE-compliant Q CE-compliant T Option None Exhaust cleaner: For D side mounting Exhaust cleaner: For U side mounting Special wiring specifications (Except double wiring) Name plate (T kit only) Direct exhaust with silencer box: Exhaust from both sides (F/L kits only) Direct exhaust with silencer box: D side exhaust Direct exhaust with silencer box: U side exhaust Enclosure IP (Except F kit) Note ) When two or more symbols are specified, indicate them alphabetically. Example) -CDK Note ) Combination of [C U] and [S U] is not possible. D D Note ) Specify the wiring specifications on the manifold specification sheet. (Except L kit) kit (Terminal block box kit) Type of connection R port P port R port Indicator light Note) Shown VVQ-CFD Manual override External pilot supply port, port Connector entry direction D side U side D U Without cable Kit F D D D Kit F U U U Cable length. m Cable length m Cable length m kit (Lead wire cable) L Electrical entry D side U side Kit L D D D Simple specials are available with Simple Special System. For details, refer to the s website. Kit L U U U Cable length. m Cable length. m Cable length m Terminal block to mounting position stations D side U side IP compatible TD TO Terminal block box to stations Note) kit S (Serial transmission unit) The valve is equipped with a lamp/surge suppressor, and the voltage is VDC. IP compatible pplicable to INPUT Unit mounting position and OUTPUT type. D U CEcompliant side side Without SI unit IP compatible F NKE Corp.: Fieldbus System H NKE Corp.: Fieldbus H System to J Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK ( output points) stations SD S J Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK ( output points) Q DeviceNet R OMRON Corp.: Compous/S System ( output points) R OMRON Corp.: Compous/S System ( output points) V CC-Link Note) For the T kit and S kit, stations are required to mount the terminal block box or SI unit, so the minimum number of stations is stations. Note) Refer to "SI Unit Part No." on page when ordering the CE-compliant SI unit. to stations Note)

7 ase Mounted Plug-in Unit Manifold Specifications Series ase model Type of connection Flow Characteristics at the Number of Manifold Stations (Operated individually) Model VVQ- F kit D-sub connector T kit Terminal block box L kit Lead wire S kit Serial transmission C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv Porting specifications, () Port size Note) port location (P), (R), (R), () C (For ø) Rc / C (For ø) Side Option C (For ø) C (For ø) Direct exhaust Rc / with Rc / ottom silencer box Rc / Note) For details about inch-size One-touch fittings and other thread standards, refer to page. position metal seal position rubber seal Note) Port size: Rc / Throttle valve spacer V-- / (P /) / / (/ E/E) / (P /) / / (/ E/E) Maximum applicable stations F, T kit stations L kit stations S kit stations pplicable solenoid valve F, L kit:.n+. S, T kit:.(n ) +. Except solenoid valve weight n: Stations Passage/Stations Station Station Station Station SUP stop valve spacer V-- Manifold Options lanking plate assembly Individual SUP spacer V-- V-P-- Individual EXH spacer V-R-- SUP/EXH block plate V- Interface regulator P RQ-- - Weight (kg) (Formula) Refer to pages to for detailed dimensions of each option. For replacement parts, refer to page. Refer to pages to for control unit. SJ SV J SZ VF VP S VQ VQ VQC VQC VQZ SQ VFS VFR VQ < EXH blocking plate > < SUP blocking plate > Release valve spacer Double (, ) V--D check spacer with residual pressure exhaust V-- () Direct exhaust with silencer box D () [-S ] U For exhaust cleaner mounting [-C ] () D U Note ) Release valve spacer and double check spacer for residual pressure exhaust cannot be combined with external pilot. Note ) Can be mounted on L kit only. For other kits, order E type control unit. (Refer to pages to.)

8 F Kit (D-sub connector kit) Simplification and labor savings for wiring work can be achieved by using a D-sub connector for the electrical connection. Using connector for flat ribbon cable (P) conforming to MIL standard permits the use of connectors put on the market and gives a wide interchangeability. Connector entry can be selected on either the U side or the D side according to the mounting orientation. Maximum stations are. Manifold Specifications Series Porting specifications, () Port size port location (P), (R), (R), () Side ottom Rc / C,, Rc /, / Rc / pplicable stations Max. stations D-Sub Connector Kit ( pins) L XT-DS- D-sub connector cable assemblies can be ordered by with manifolds. Refer to How to Order Manifold. x M. x. Socket side. Multi-core vinyl cable. mm x C ø Terminal no. D-sub Connector Cable ssembly Cable ssembly part no. length (L). m m m XT-DS- XT-DS- XT-DS- Note Cable cores x WG For other commercial connectors, use a pins type with female connector conforming to MIL-C-. Cannot be used for transfer wiring. Connector manufacturers example Fujitsu, Ltd. Japan viation Electronics Industry, Ltd. J.S.T. Mfg. Co., Ltd. Hirose Electric Co., Ltd. Note) Lengths other than the above are also available. Please contact for details. Electric Characteristics Item Characteristics Conductor resistance or Ω/km, C less Voltage limit VC, min. Insulation resistance or less MΩkm, C Note) The minimum bending radius for D-sub connector cables is mm. Cable assembly D-sub Connector Cable ssembly Terminal No. Terminal no. Lead wire color Dot marking lack rown Red Orange Yellow Pink lue Purple Gray White White Yellow Orange Yellow Pink lue Purple Gray Orange Red rown Pink Gray lack White None None None None None None None White lack lack Red Red Red lack lack White None None lack White White Red Red White None How to Order Manifold VVQ Series Manifold Plug-in unit Stations station C Cylinder port C With One-touch fitting for ø stations C With One-touch fitting for ø C With One-touch fitting for ø C With One-touch fitting for ø CM Rc / Rc / ottom ported Rc / Mixed F U Thread type Connector entry direction D D side entry U U side entry Cable (Length) Note) s a semi-standard specification, the maximum number of stations can be increased by special wiring specifications. For details, refer to page. F T Rc G NPT/NPTF Without cable Cable length. m Cable length m Cable length m CE compliant Q CE compliant Option Option Symbol CD () CU () K () S SD () SU () [Option] None Exhaust cleaner: For D side mounting Exhaust cleaner: For U side mounting Special wiring specifications (Except double wiring) Direct exhaust with silencer box: Exhaust from both sides Direct exhaust with silencer box: D side exhaust Direct exhaust with silencer box: U side exhaust Note ) When two or more symbols are specified, indicate them alphabetically. Example) -CDK Note ) Combination of [C U ] and [S U D D ] is not possible. Note ) Specify the wiring specifications on the manifold specification sheet. Note ) Refer to pages to for with control unit.

9 ase Mounted Plug-in Unit D side U side Stations Stations are counted starting from the first station on the D side. Special Wiring Specifications Double wiring (connected to SOL. and SOL. ) is used for the internal wiring of each station regardless of valve and option types. Mixed single and double wiring is available as a semi-standard specification.. How to order Indicate option symbol -K in the manifold part number and be sure to specify station positions for single or double wiring on the manifold specification sheet. How to Order Valves VQ Series Type of actuation position single position double position closed center position exhaust center position pressure center position double check Y () R () Seal Metal seal Rubber seal Function Standard type ( W) Low wattage type (. W) External pilot Electrical wiring specifications D-sub connector assembly Standard wiring Wiring with control unit D-sub connector XT-DS- Wire colors Terminal no. Polarity Lead wire Dot color marking SOL. Release valve ( ) (+) lack None station SOL. (+) ( ) Yellow lack SOL. Pressure switch ( ) (+) rown None stations SOL. ( ) (+) Pink lack SOL. SOL. ( ) (+) Red None stations SOL. SOL. ( ) (+) lue White SOL. SOL. (+) ( ) Orange None stations SOL. SOL. ( ) (+) Purple None SOL. SOL. ( ) (+) Yellow None stations SOL. SOL. (+) ( ) Gray None SOL. SOL. ( ) (+) Pink None stations SOL. SOL. ( ) (+) Orange lack SOL. SOL. ( ) (+) lue None stations SOL. SOL. ( ) (+) Red White SOL. SOL. ( ) (+) Purple White stations SOL. SOL. ( ) (+) rown White Connector terminal no. SOL. SOL. ( ) (+) Gray lack stations SOL. SOL. (+) Double wiring (connected to ( ) Pink Red SOL. SOL. SOL. and SOL. ) is adopted for the internal wiring ( ) (+) Gray Red (+) White lack stations ( ) SOL. SOL. of each station, regardless SOL. SOL. ( ) (+) White Red of valve and option types. stations SOL. SOL. ( ) (+) lack White Mixed single and double SOL. SOL. wiring is available a semistandard specification. For ( ) (+) White None ( ) (+) Yellow Red stations SOL. SOL. details, refer to below. COM. (+) ( ) Note) Orange Red Note) There is no polarity. Positive Negative common common It can also be used as a negative common. specifications specifications Coil voltage Manual override VC (/ Hz) VC (/ Hz) VC (/ Hz) VC (/ Hz) VDC VDC Note ) pplicable to DC specifications. Please select when you expect to energize the unit for extended periods of time. Refer to page for details. Note ) Refer to page for external pilot specification. Combination of external pilot and perfect interface is not possible. Note ) When two or more symbols are specified, indicate them alphabetically. E. Wiring specifications Connections begin with the side solenoid of the first station being connected to terminal no., and continue in the order indicated by the arrows in the drawing without skipping any terminals. Maximum stations are. COM D-sub connector [Option] CE-compliant Q CE-compliant Non-locking push type (Tool required) Locking type (Tool required) Light/Surge voltage suppressor Yes Without light, with surge voltage suppressor How to Order Manifold ssembly Specify the part numbers for valves and options together beneath the manifold base part number. <Example> D-sub connector kit with cable ( m) VVQ-CFD(-Q) set Manifold base part no. -(-Q) sets Valve part no. (Stations and ) -(-Q) sets Valve part no. (Stations and ) -(-Q) set Valve part no. (Station ) Prefix the asterisk to the part nos. of the solenoid valve, etc. Enter in order starting from the first station on the D side. When entry of part numbers becomes complicated, indicate in the manifold specification sheet. m D side U side Stations SJ SV J SZ VF VP S VQ VQ VQC VQC VQZ SQ VFS VFR VQ

10 X F Kit (D-sub connector kit) R P R PE. U side Connector location on U side (FU) L L P= X pplicable connector: D-sub connector (P) (Conforming to MIL-C-) x Rc / (Pilot EXH port) n x Rc /, /, C, C, C, () port Rc /: Rc / thread x Rc / (P), (R), (R) port Rc /: Rc / thread C: One-touch fitting for ø C: One-touch fitting for ø C: One-touch fitting for ø C: One-touch fitting for ø. x Rc/ (External pilot port) M x. Ground screw Manual override Indicator light n Stations... P= Connector location on D side (FD) R. D side (Single) (Double) ( position)....

11 ase Mounted Plug-in Unit ottom ported drawing SJ U side D side x Rc / (External pilot port) X X..... P=. M x. Ground screw n x Rc /, () port n Stations L L P=.. Connector location on U side (FU) Connector location on D side (FD) SV J SZ VF VP S VQ VQ VQC VQC VQZ SQ VFS VFR VQ Dimensions L n L L Formula L = n +, L = n + n: Station (Maximum standard stations)

12 T Kit (Terminal block box kit) IP compliant Enclosure IP compliant This type has a small terminal block inside a junction box. The provision of a G / electrical entry allows connection of conduit fittings. Maximum stations are. stations are used for terminal box mounting. Terminal lock Connections Manifold Specifications Series Porting specifications, () Port size port location (P), (R), (R), () Side ottom C,, Rc / Rc /, / Rc / pplicable stations Max. stations Step. How to remove terminal block cover Loosen the mounting screws (M) and open the terminal block cover. Mounting screw (M) Terminal block cover Step. The diagram on the right shows the terminal block wiring. ll stations are provided with double wiring regardless of the valves which are mounted. Connect each wire to the power supply side, according to the markings provided inside the terminal block. M screw Gasket mm Electrical entry x G/ Step. How to attach the terminal block cover Securely tighten the screws with the torque shown in the table below, after confirming that the gasket is installed correctly. pplicable terminal.-s,.y-,.y-n,.y-. Proper tightening torque (N m) Name plate: VVQ-N-T. to. Drip proof plug assembly (for G /): XT- How to Order Manifold VVQ Series Manifold Plug-in unit Stations stations stations Note) stations are used for mounting the terminal block box. The number of stations is the number of manifold valves plus stations for the terminal block box. For stations or more, specify the wiring specifications by means of the manifold specification sheet. T C Cylinder port C With One-touch fitting for ø C With One-touch fitting for ø C With One-touch fitting for ø C With One-touch fitting for ø Rc / Rc / ottom ported Rc / CM Mixed Note) s a semi-standard specification, the maximum number of stations can be increased by special wiring specifications. For details, refer to page. ox mounting position O D Thread type F T U side mounting D side mounting Rc G NPT/NPTF [Option] CE-compliant Q CE-compliant Option Symbol Option None CD () Exhaust cleaner: For D side mounting CU () Exhaust cleaner: For U side mounting K () Special wiring specifications (Except double wiring) N () Name plate SD () Direct exhaust with silencer box: D side exhaust SU () Direct exhaust with silencer box: U side exhaust W IP enclosure Note ) When two or more symbols are specified, indicate them alphabetically. Example) -CDK Note) Combination of [CD] and [SD] is not possible. Note) Specify the wiring specifications on the manifold specification sheet. Note ) Name plate is inlaid in the terminal block cover. Note ) Refer to pages to for with control unit.

13 ase Mounted Plug-in Unit x G / Electrical entry Electrical wiring specifications COM COM How to Order Valves VQ Series Type of actuation position single position double position closed center position exhaust center position pressure center position double check Seal Metal seal Rubber seal Function station stations stations stations stations stations Double wiring (connected to stations SOL. and SOL. ) is adopted for the internal stations wiring of each station, regardless of valve and option types. stations Mixed single and double wiring is available as a stations semi-standard specification. Note) There is no polarity. It can also be used as a negative common. Y () R () Standard type ( W) Low wattage type (. W) External pilot Stations are counted starting from the first station on the D side. Standard wiring Wiring with control unit Terminal no. Terminal no. Polarity SOL. Release valve ( ) (+) SOL. (+) ( ) SOL. Pressure switch ( ) (+) SOL. (+) ( ) SOL. SOL. ( ) (+) SOL. SOL. ( ) (+) SOL. SOL. ( ) (+) SOL. SOL. ( ) (+) SOL. SOL. ( ) (+) SOL. SOL. ( ) (+) SOL. SOL. ( ) (+) SOL. SOL. ( ) (+) SOL. SOL. ( ) (+) SOL. SOL. ( ) (+) SOL. SOL. ( ) (+) SOL. SOL. ( ) (+) SOL. SOL. ( ) (+) SOL. SOL. ( ) (+) SOL. SOL. ( ) (+) SOL. SOL. ( ) (+) COM COM (+) ( ) Positive Negative common common CE-compliant Q CE-compliant Enclosure Dust tight Dust tight/low W jetproof type (IP) Manual override Non-locking push type (Tool required) Locking type (Tool required) Ligh/Surge voltage suppressor E Note ) pplicable to DC specifications.please select when you expect to energize the unit for extended periods of time. Refer to page for details. Note ) Refer to page for external pilot specification. Combination of external pilot and perfect interface is not possible. Note ) When two or more symbols are specified, indicate them alphabetically. [Option] Yes Without light, with surge voltage suppressor Coil voltage VC (/ Hz) VC (/ Hz) VC (/ Hz) VC (/ Hz) VDC VDC Special Wiring Specifications Double wiring (connected to SOL. and SOL. ) is used for the internal wiring of each station regardless of valve and option types. The optional specification permits mixture of single and double wiring. However, the maximum number of stations is.. How to Order Indicate option symbol -K in the manifold part number and be sure to specify station positions for single or double wiring on the manifold specification sheet.. Wiring specifications Connections begin with the side solenoid of the first station being connected to terminal no., and continue in the order indicated by the arrows in the drawing without skipping any terminals. COM How to Order Manifold ssembly COM Specify the part numbers for valves and options together beneath the manifold base part number. <Example> Terminal block box kit VVQ-CT(-Q) set Manifold base part no. -(-Q) sets Valve part no. (Stations and ) -(-Q) sets Valve part no. (Stations and ) -(-Q) set Valve part no. (Station ) Prefix the asterisk to the part nos. of the solenoid valve, etc. Enter in order starting from the first station on the D side. When entry of part numbers becomes complicated, indicate in the manifold specification sheet. D side U side Stations SJ SV J SZ VF VP S VQ VQ VQC VQC VQZ SQ VFS VFR VQ

14 U SIDE ST TERMin.NL NO. D SIDE PE R P R T Kit (Terminal block box kit) x Rc / (Pilot EXH port). x Rc / (P), (R), (R) port n x Rc /, /, C, C, C, () port Rc /: Rc / thread Rc /: Rc / thread C: One-touch fitting for ø C: One-touch fitting for ø C: One-touch fitting for ø C: One-touch fitting for ø M x. Ground screw U side When U side mounting (TO) When D side mounting (TD). x G / (Conduit port). Manual override D side L L Indicator light P= (Single) (Double) ( position) R. n Stations x Rc / (External pilot port). X X.... P=... Note) Shown VVQ-CTO-W

15 ase Mounted Plug-in Unit ottom ported drawing x G / U side (Conduit port) x Rc / (External pilot port) D side. X X... M x. Ground screw.. P=.. n x Rc /, () port n Stations L L P=.. SJ SV J SZ VF VP S VQ VQ VQC VQC VQZ SQ VFS VFR VQ Dimensions L n L L Formula L = n +, L = n + n: Station (Maximum standard stations) Including stations for terminal box.

16 L Kit (Lead wire cable) IP compliant Enclosure IP compliant Direct electrical entry. Models with two or more stations are available. Electrical entry can be selected on either the U side or the D side according to the mounting orientation. Maximum stations are. Wiring Specifications Manifold Specifications Series Porting specifications, () Port size port location (P), (R), (R), () Side ottom Rc / C,, Rc /, / Rc / pplicable stations Max. stations Three lead wires are attached to each station regardless of the type of valve which is mounted. The red wire is for COM connection. SOL. COM SOL. Lead wire color ( ) (+) lack (+) ( ) Red ( ) (+) White Positive common Single solenoid Negative common Lead wire color SOL. ( ) (+) lack COM (+) ( ) Red SOL. ( ) (+) White Positive Negative common common Double solenoid Lead Wire ssembly with Connector Lead wire length. m. m m : Number of stations to. Part no. VVQ--- VVQ--- VVQ--- lack: side solenoid Red: COM Station number Cable: core x WG White: side solenoid (Not used for single solenoid) For different lead wire lengths, order a lead wire assembly with connector shown in the table on the right. Note ) There is no polarity. It can also be used as a negative common. Note ) Connect the release valve and the pressure switch to SOL. side on the manifold with control unit. How to Order Manifold VVQ Series Manifold Plug-in unit stations Stations station C Cylinder port C With One-touch fitting for ø C With One-touch fitting for ø C With One-touch fitting for ø C With One-touch fitting for ø Rc / Rc / ottom ported Rc / CM Mixed F T Thread type Rc G NPT/NPTF L U Option Symbol CD CU S SD SU W Cable (Length) Cable length. m Cable length. m Cable length m Connector locations D U D side entry U side entry CE-compliant Q CE-compliant [Option] Option None Exhaust cleaner: For D side mounting Exhaust cleaner: For U side mounting Direct exhaust with silencer box: Exhaust from both sides Direct exhaust with silencer box: D side exhaust Direct exhaust with silencer box: U side exhaust IP enclosure Note) When two or more symbols are specified, indicate them alphabetically. Example) -CDW

17 ase Mounted Plug-in Unit How to Order Valves VQ Series Type of actuation position single position double position closed center position exhaust center position pressure center position double check Seal Metal seal Rubber seal D side U side Stations E Cable length CE-compliant Q CE-compliant Enclosure Dust tight Dust tight/low jetproof type W (IP) Manual override Non-locking push type (Tool required) Locking type (Tool required) Light /Surge voltage suppressor Yes Without light, with surge voltage suppressor The drawing shows the electrical entry on the D side. Cable length is measured from the solenoid valve body. [Option] How to Order Manifold ssembly Specify the part numbers for valves and options together beneath the manifold base part number. <Example> Lead wire kit with cable ( m) VVQ-CLD(-Q) set Manifold base part no. -(-Q) sets Valve part no. (Stations and ) -(-Q) sets Valve part no. (Stations and ) -(-Q) set Valve part no. (Station ) Prefix the asterisk to the part nos. of the solenoid valve, etc. Enter in order starting from the first station on the D side. When entry of part numbers becomes complicated, indicate in the manifold specification sheet. D side U side Stations SJ SV J SZ VF VP S VQ VQ VQC VQC VQZ SQ VFS VFR VQ Function Y () R () Standard type ( W) Low wattage type (. W) External pilot Note ) pplicable to DC specification. Please select when you expect to energize the unit for extended periods of time. Refer to page for details. Note ) Refer to page for external pilot specification. Combination of external pilot and perfect interface is not possible. Note ) When two or more symbols are specified, indicate them alphabetically. Coil voltage VC (/ Hz) VC (/ Hz) VC (/ Hz) VC (/ Hz) VDC VDC

18 L Kit (Lead wire cable) PE. R P R U side x G / (Electrical entry) x Rc / (Pilot EXH port) n x Rc /, /, C, C, C, () port Rc /: Rc / thread x Rc / (P), (R), (R) port Rc /: Rc / thread C: One-touch fitting for ø C: One-touch fitting for ø Lead wire length C: One-touch fitting for ø L: mm C: One-touch fitting for ø Station number Electrical entry on U side (LU). L: mm L: mm x Rc / (External pilot port) M x. Ground screw. Manual override Indicator light L L P= n Stations X X.. P= D side Electrical entry on D side (LD) (Single) R.. (Double) ( position)...

19 X ase Mounted Plug-in Unit ottom ported drawing SJ U side x Rc / (External pilot port) X.. Lead wire length L: mm L: mm L: mm M x. Ground screw n x Rc /, () port. P= n Stations L L P= Station number Electrical entry on U side (LU) Electrical entry on D side (LD) SV J SZ VF VP S VQ VQ VQC VQC VQZ SQ VFS D side..... VFR VQ Dimensions L n L L Formula L = n +, L = n + n: Station (Maximum stations)

20 S Kit (Serial transmission unit): EX/ (For Output) Serial Transmission System IP compliant The serial transmission system reduces wiring work, while minimizing wiring and saving space. Manifold Specifications Series Porting specifications, () port Port size port location (P),(R), (R), () Side ottom C,, Rc / Rc /, / Rc / pplicable stations Max. stations Double wiring (connected to SOL. and SOL. ) is adopted for the internal wiring of each station, regardless of valve and option types. Item Specifications External power supply VDC +%, % Current consumption (Internal unit). How to Order Manifold VVQ Series Manifold Plug-in unit S C V Stations stations stations Note) stations are used for mounfing SI unit. The number of stations is the number of manifold valves plus stations for SI unit. For stafions or more, specify the wiring specifications by means of the manifold specification sheet. Stations are counted starting from the first station on the D side. D side U side Stations Cylinder ports C With One-touch fitting for ø C With One-touch fitting for ø C With One-touch fitting for ø C With One-touch fitting for ø Rc / Rc / ottom ported Rc / CM Mixed F T G / Thread type SI unit mounting position D Rc G NPT/NPTF U side mounting D side mounting Drip proof plug assembly (for G /): XT- SI Unit Part No. Symbol Protocol type F NKE Corp.: Fieldbus System H J J Q R R V Option Symbol CD () CU () K () SD () SU () W () SI unit F H J J Q R R V Option None Exhaust cleaner: D side mounting Exhaust cleaner for Rc : U side exhaust Special wiring specifications (Except double wiring) Direct exhaust with silencer box: D side exhaust Direct exhaust with silencer box: U side exhaust IP enclosure Without SI unit NKE Corp.: Fieldbus System NKE Corp.: Fieldbus H System Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK ( output points) Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK ( output points) DeviceNet OMRON Corp.: Compous/S System ( output points) OMRON Corp.: Compous/S System ( output points) CC-Link NKE Corp.: Fieldbus H System DeviceNet OMRON Corp.: Compous/S System ( output points) OMRON Corp.: Compous/S System ( output points) CC-Link Note) Refer to SI Unit Part No. when ordering the CE-compliant SI unit. SI unit part no. CE compliant D side: EXD-SUW U side: EXU-SUW D side: EXD-SUH U side: EXU-SUH D side: EXD-SSL U side: EXU-SSL D side: EXD-SSL U side: EXU-SSL D side: EXD-SDN U side: EXU-SDN D side: EXD-SCS U side: EXU-SCS D side: EXD-SCS U side: EXU-SCS D side: EXD-SMJ U side: EXU-SMJ CE-compliant Q [Option] CE-compliant Note) Refer to SI Unit Part No. when ordering the CEcompliant SI unit. Note ) When two or more symbols are specified, indicate them alphabetically. Example) -CDK Note ) Combination of [CD] and [SD] is not possible. Note ) Specify the wiring specifications in the manifold specification sheet. Note ) Refer to pages to for with control unit.consumption of C type. Note ) The release valve and the pressure switch on the manifold with control unit are connected to another power supply. Cable length is. m for L kit. Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK ( output points) Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK ( output points) Page P. Refer to page and the Operation Manual for the details of EX/ Integratedtype (For Output) Serial Transmission System. Please download the Operation Manual via our website,

21 ase Mounted Plug-in Unit How to Order Valves VQ Series Type of actuation position single position double position closed center position exhaust center position pressure center position double check Seal Metal seal Rubber seal Function Y () R () E Light /Surge voltage suppressor Coil voltage VDC Enclosure Dusttight Dusttight/Low jetproof type W (IP) Manual override Non-locking push type (Tool required) Locking type (Tool required) Yes Without light, with surge voltage suppressor Standard type ( W) Low wattage type (. W) External pilot Note ) pplicable to DC specifications. Please select when you expect to energize the unit for extended periods of time. Refer to page for details. Note ) For external pilot specifications, refer to page. Combination of the external pilot and perfect interface is not possible. Note ) When two or more symbols are specified, indicate them alphabetically. [Option] CE-compliant Q CE-compliant How to Order Manifold ssembly [Order example] Specify the part numbers for valves and options together beneath the manifold base part number. <Example> VVQ-CSV(-Q) set Manifold base part no. -(-Q) sets Valve part no. (Stations and ) -(-Q) sets Valve part no. (Stations and ) -(-Q) set Valve part no. (Station ) Prefix the asterisk to the part nos. of the solenoid valve, etc. Enter in order starting from the first station on the D side. When entry of part numbers becomes complicated, indicate in the manifold specification sheet. D side U side Stations SJ SV J SZ VF VP S VQ VQ VQC VQC VQZ SQ VFS VFR VQ

22 R R P PE S Kit (Serial transmission unit): EX/ (For Output) Serial Transmission System x Rc / (Pilot EXH port). x Rc / (P), (R), (R) port n x Rc /, /, C, C, C {, () port} U side SI Unit When U side mounting (S ) When D side mounting (SD ) () x G / Note) (Conduit port). Rc /: Rc / thread Rc /: Rc / thread C: One-touch fitting for ø C: One-touch fitting for ø C: One-touch fitting for ø C: One-touch fitting for ø M x. Ground screw Note) Manual override Indicator light D side L L P= (Single) (Double) ( position) R. n Stations x Rc / (External pilot port). X X..... P=.. Dimensions L n L L Formula L = n +, L = n + n: Station (Maximum standard stations) Including stations for mounting SI unit box. Note) In the case of EX for SI unit, conduit port (G /) will be locations. In the case of EXD (U), conduit port will be locations. Note) In the case of EX (D)-SMJI, this dimension becomes. Note) Shown VVQ-CSQ-W

23 ase Mounted Plug-in Unit () G / (Conduit port) Note) U side M x. Ground screw n x Rc /, () port SJ SV D side x Rc / (External pilot port). X X.... P=.. n Stations L L P=.. J SZ VF VP S VQ VQ VQC VQC VQZ SQ VFS VFR VQ Dimensions L n L L Formula L = n +, L = n + n: Station (Maximum standard stations) Including stations for mounting SI unit box.

24 ase Mounted Plug Lead Unit: C Kit (Connector kit) [Option] How to Order Manifold VVQ Series Manifold Plug lead unit C W Stations station stations Cylinder port C With One-touch fitting for ø C With One-touch fitting for ø C With One-touch fitting for ø C With One-touch fitting for ø Rc / Rc / ottom ported Rc / CM Mixed How to Order Valves C Kit type kit (Connector) C C Connector kit Thread type F T Rc G NPT/NPTF Max. stations CE-compliant Q CE-compliant Option Symbol Option None CD () Exhaust cleaner: For D side mounting CU () Exhaust cleaner: For U side mounting S Direct exhaust with silencer box: Exhaust from both sides SD () Direct exhaust with silencer box: D side exhaust SU () Direct exhaust with silencer box: U side exhaust W IP enclosure Note ) When two or more symbols are specified, indicate them alphabetically. Example) -CDW U U Note ) Combination of [C D] and [S D] is not available. Refer to page (Grommet type) for wiring specifications. Control unit Refer to pages to. How to Order Manifold ssembly VQ Series Type of actuation Y () R () position single position double position closed center position exhaust center position pressure center position double check Seal Metal seal Rubber seal Function Standard type ( W) Low wattage type (. W) External pilot Note ) pplicable to DC specifications. Please select when you expect to energize the unit for extended periods of time. Refer to page for details. Note ) For external pilot specifications, refer to page. Combination of the external pilot and perfect interface is not possible. Note ) When two or more symbols are specified, indicate them alphabetically. VC (/ Hz) VC (/ Hz) VC (/ Hz) G Coil voltage VC (/ Hz) VDC VDC CE-compliant Q CE-compliant Enclosure Dusttight Dusttight/Low W jetproof type (IP) Manual override : : Non-locking push type Locking type (Tool required) (Tool required) Light/Surge voltage suppressor E Electrical entry Grommet G Lead wire length. m H Lead wire length. m Yes Without light, with surge voltage suppressor Specify the part numbers for valves and options together beneath the manifold base part number. <Example> Connector kit VVQ-CC(-Q) set -G(-Q) sets -G(-Q) sets -G(-Q) set Prefix the asterisk to the part nos. of the solenoid valve, etc. Manifold base part no. Valve part no. (Stations and ) Valve part no. (Stations and ) Valve part no. (Station ) Enter in order starting from the first station on the D side. When entry of part numbers becomes complicated, indicate in the manifold specification sheet. D side U side Stations Simple specials are available with Simple Special System. For details, refer to the website.

25 ase Mounted Plug Lead Unit: C Kit (Connector kit) Manifold Specifications Series ase model Type of connection Rc / Flow Characteristics at the Number of Manifold Stations (Operated individually) Model VVQ- Manifold Options lanking plate assembly V-- C kit Grommet, () port location Side ottom Passage/Stations C [dm /(s bar)] / (P /) b Cv C [dm /(s bar)] / / (/ E/E) b Cv C [dm /(s bar)] / (P /) b Cv C [dm /(s bar)] / / (/ E/E) b Cv Porting specifications Port size Note) (P), (R), (R), () Rc / Option Direct exhaust with silencer box Note) For details about inch-size One-touch fittings and other thread standards, refer to page. position metal seal position rubber seal Note) Port size: Rc / Throttle valve spacer V-- Individual SUP spacer V-P-- SUP stop valve spacer V C (For ø) C (For ø) C (For ø) Rc / Rc / Maximum applicable stations to stations pplicable solenoid valve Weight (kg) (Formula).n+. Except solenoid valve weight n: Stations Station Station Station Station Individual EXH spacer V-R-- SUP/EXH block plate V- Interface regulator P RQ Refer to pages to for detail dimensions of each option. For replacement parts, refer to page. Refer to pages to for control unit. SJ SV J SZ VF VP S VQ VQ VQC VQC VQZ SQ VFS VFR VQ < SUP blocking plate > < EXH blocking plate > Release valve spacer V--D Note) Double check spacer with residual pressure exhaust V-- Note) Direct exhaust with silencer box [-S D ] Note) U For exhaust cleaner mounting [-C ] Note) D U Note) Release valve spacer, built-in silencer (direct exhaust), exhaust cleaner mounting style and perfect double check spacer for residual pressure exhaust cannot be combined with external pilot.

26 C Kit (Connector kit) R P R PE. X x Rc / (Pilot EXH port). x Rc / (P), (R), (R) port. ( position).. (Double). (Single). R. x Rc/ (External pilot port) U side.. M x. Ground screw. n X n x Rc /, /, C, C, C, () port P= L L Rc /: Rc / thread Rc /: Rc / thread C: One-touch fitting for ø C: One-touch fitting for ø C: One-touch fitting for ø C: One-touch fitting for ø P= Cable length ( or mm) Stations.. Indicator light Manual override D side..

27 X ase Mounted Plug Lead Unit: C Kit (Connector kit) ottom ported drawing SJ U side x Rc / (External pilot port) X. M x. Ground screw P= n x Rc /, () port n L L P=. SV J SZ VF VP S VQ VQ VQC D side..... Stations... Cable length ( or mm) VQC VQZ SQ VFS VFR VQ Dimensions Formula L = n +, L = n + n: Station (Maximum stations) L n L L

28 Manifold Option Parts lanking plate assembly V-- (Plug-in type) V-- (Plug lead type) It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. Plug-in type Plug lead type () (R) (P) (R) Circuit diagram (Plug-in type). (Plug lead type). Individual SUP spacer V-P-- (Plug-in type) V-P-- (Plug lead type) y mounting individual SUP spacers on a manifold block, it is possible to provide individual supply ports for each valve. (P) (Plug-in type). (Plug lead type).. (P') () V-P- -:Rc / V-P- -:Rc / (R) (R) Plug-in type Plug lead type Circuit diagram Individual EXH spacer V-R-- (Plug-in type) V-R-- (Plug lead type) y mounting individual EXH spacers on a manifold block, exhaust ports can be provided individually for each valve. (Common EXH type) (Plug-in type). (Plug lead type).. (P) () V-R- -:Rc / V-R- -:Rc / (R') Plug-in type Plug lead type (R) (R) Circuit diagram

29 P U S H ase Mounted Throttle valve spacer V-- (Plug-in type) V-- (Plug lead type) throttle valve spacer is mounted on a manifold block to control cylinder speed by throttling exhaust air flow. Plug-in type Plug lead type SUP stop valve spacer V-- (Plug-in type) V-- (Plug lead type) SUP stop valve spacer is mounted on a manifold block, making it possible to individually shut off supply air to each valve. Plug-in type Release valve spacer: For D side mounting V--D (Plug-in type) V--D (Plug lead type) Combination of (Single) and release valve spacer can be used as air release valve. Note ) Mounting on position double and position valve is not possible. Note ) Can be mounted on L kit only. For other kits, order E type control unit. (Refer to pages to.) (R) (P) (P) (R) Circuit diagram (R) (R) Circuit diagram Plug lead type (R) (P) (R) Po () Circuit diagram () P (Plug-in type). (Plug lead type) Rc / SUP port. (Plug lead type) Po (Plug-in type). (Plug lead type). (Plug-in type). LOCK FREE SJ SV J SZ VF VP S VQ VQ VQC VQC VQZ SQ VFS VFR VQ Plug-in type Plug lead type SUP/EXH block plate V- When supplying two different pressures to one manifold, this is used to shut off between stations with different pressures... R P R SUP passage blocked R P R EXH passage blocked R P R SUP/EXH passage blocked <SUP blocking plate> <EXH blocking plate>

30 LOCK Manifold Option Parts Direct exhaust with silencer box VVQ S (Exhaust from both sides) VVQ SD (D side exhaust) VVQ SU (U side exhaust) The EXH outlet is placed on the top side of the manifold end plate. The built-in silencer provides highly effective noise reduction. (Noise reduction of d or more) Effective area:. mm Note) If a lot of drainage is generated at air supply source, both of exhaust air and drainage are exhausted. Type SD. X R P R PE Note) Figure shows VVQ SD. Silencer box assembly: V- (With gasket, screw) Type SU Double check spacer with residual pressure exhaust V (Plug-in type) V (Plug lead type) Can hold an intermediate cylinder position for an extended time. If the double check spacer with a built-in double check valve is combined, it will enable the cylinder to stop in the intermediate stroke and maintain its position for a long time without being affected by the leakage between the spools. esides, combination between position solenoid valve ( ) and double check spacer can t hold an intermediate position, but can prevent dropping at the cylinder stroke end. Plug-in type Specifications Double check V-- spacer part no. Intermediate stop Drop prevention pplicable solenoid valve (Plug-in type). (Plug lead type) Caution Handling Precautions ir leakage from the pipe between the valve and cylinder or from the fittings will prevent the cylinder from stopping in the middle for a long time. Check for leakage using a neutral household detergent, such as dish washing soap. lso, check the cylinder sealing and piston seal for leakage. Since One-touch fittings allow slight air leakage, screw piping is recommended when stopping the cylinder in the middle for a long time. If exhaust side of double check spacer is narrowed down, this causes a decrease in intermediate stop accuracy and may malfunction. Combining perfect interface with position valves will not work. Set the cylinder load so that the cylinder pressure will be within two times that of the supply pressure. Combining double check spacer with external pilot will not work.. Plug lead type Manual override for residual pressure exhaust Slotted locking type (Tool required)

31 ase Mounted Manifold mounted exhaust cleaner VVQ - -CD (D side mounting) VVQ - -CU (U side mounting) n adapter plate for exhaust cleaner mounting is provided on the top of the manifold end plate. The exhaust cleaner collects drainage and oil mist (.% or more) and is highly effective for noise reduction. (Noise reduction of d or more) Station number U side entry (LU) U side Manual override Indicator light L L D side D side entry (LD) MC- Exhaust cleaner x G Rc / Electrical entry Plug-in type P= Lead wire length L: mm L: mm L: mm ( position) (Double) (Single) R.. x Rc / (External pilot port) n. Stations x Rc / (P) port x Rc / (Pilot EXH port) n x Rc /, /, C, C, C, () port Rc /: Rc / thread Rc /: Rc / thread C: One-touch fitting for ø C: One-touch fitting for ø C: One-touch fitting for ø.. D side mounting.. P=.. D side U side ø U side mounting pplicable exhaust cleaners MC- (Port size Rc ) Note ) Exhaust cleaner MC- is not attached. Please order it separately. Note ) Mount so that the exhaust cleaner is at the lower side. Note ) For details about the exhaust cleaner, refer to est Pneumatics No.. Plug lead type Indicator light Manual override MC- Exhaust cleaner. ( position).. (Double). (Single). R. P= L L. x Rc / (External pilot port) x Rc / (P) port x Rc / (Pilot EXH port) n x Rc /, /, C, C, C, () port Rc /: Rc / thread Rc /: Rc / thread C: One-touch fitting for ø C: One-touch fitting for ø C: One-touch fitting for ø U side n Stations D side.. D side mounting.. P=.. D side U side ø U side mounting SJ SV J SZ VF VP S VQ VQ VQC VQC VQZ SQ VFS VFR VQ Dimensions L n L Formula L = n +, L = n + n: Stations (Maximum stations) Dimensions L n L Formula L = n +, L = n + n: Stations (Maximum stations) L L L L n L L n L L

32 Manifold Option Parts Interface regulator (P,, port regulation) RQ-- - (Plug-in type) RQ-- - (Plug lead type) Spacer Interface regulators can be placed on top of the manifold block to reduce the pressure of each of the valves. Specifications Interface regulator RQ Regulating port P pplicable solenoid valve Plug-in Plug lead Plug-in Plug lead Plug-in Plug lead Maximum operating pressure Set pressure range Fluid mbient and fluid temperature Port size for connection of pressure gauge. MPa. to. MPa ir to C (No freezing) M x. Weight (kg) Effective area at supply side (mm ) P S at P =. MPa/P =. MPa P Effective area at exhaust side (mm ) E S at P =. MPa E Note ) Set the pressure within the operating pressure range of the solenoid valve. Note ) Operate an interface regulator only by applying pressure from the P port of the base, except when using it as a reverse pressure valve. When using it as a reverse pressure valve, P port regulation is not allowed to use. Note ) When using a perfect spacer, assemble a valve, a spacer regulator and a perfect spacer in this order to use it. Note ) When using in port regulation, port regulation by closed center, since there is a problem in its operation, please contact. Note ) Dust tight/low jetproof enclosure (IP) is not available with interface regulator. How to Order Solenoid Valve (Plug-in type) (Plug lead type) R P R. PE Interface regulator RQ--- RQ--- RQ--P- RQ--- RQ--- RQ--P-. Regulating port P P Regulating port: Regulating port: Regulating port: P Flow Characteristics Conditions Inlet pressure:. MPa RQ-- Outlet pressure (MPa) RQ-- Outlet pressure (MPa) RQ--P (P ) Outlet pressure (MPa) RQ--P (P ) Outlet pressure (MPa) Pressure Characteristics Flow rate (L/min(NR)) Flow rate (L/min(NR)) Flow rate (L/min(NR)) Flow rate (L/min(NR)) Conditions Inlet pressure:. MPa Outlet pressure:. MPa Flow rate: L/min (NR) Outlet pressure (MPa) Set point Inlet pressure (MPa)

33 ase Mounted Semi-standard Specifications External Pilot Specifications When the supply air pressure is: lower than the required minimum operating pressure. to. MPa, opposite air supply (R port supply), cylinder supply ( and port supply), used for vacuum specifications (please contact ), it can be used for external pilot specifications. Order a valve by adding the external pilot specification [R] to the part number. External pilot is available as standard for manifolds and options. Internal/external pilot can be mounted in a manifold. Compatibility with universal porting is possible for the single, double and P (excluding perfect spacer) types. How to Order Manifold R Pressure Specifications External pilot specifications External pilot port Rc / <Sub-plate> Valve construction Metal seal Rubber seal Operating pressure range External pilot Note) pressure range Single Double position External pilot port x Rc / <Manifold> Note) Possible to mix mounting of internal and external pilot Vacuum to. MPa. to. MPa (. to. MPa) Note ) Values inside ( ) denote the low wattage (. W) specifications. Combination of manifold options shown below and external pilot specification is not possible.. to. MPa (. to. MPa). to. MPa (. to. MPa). to. MPa (. to. MPa) Release valve spacer Direct exhaust with silencer box V-- D VVQ S U For exhaust cleaner mounting VVQ C D Manifold with control unit VVQ Control unit model no. Double check spacer with residual pressure exhaust V Inch-size One-touch Fittings Valve with inch size One-touch fittings is shown below. How to Order Single Valves VVQ N S K Cylinder port N N N How to Order Manifold VVQ VVQ T T FU ø/" ø/" ø/" International Thread Standards Rc specifications are standard for all ports, however, NPT, NPTF and G are available for international markets. dd the appropriate symbol following the port size in the standard part number. How to Order Single Valves (Example) Thread type (P, R and, port) Rc NPT NPTF G Rc NPT NPTF G How to Order Sub-plates and Options (Example) V Cylinder port Port size Cylinder port Port size N T F C T FU Cylinder port Port size P P Thread type (P, R and, port) N T F Port size Thread type (P, R port) Rc N NPT T NPTF F G N T (Sub-plate) (Option) Thread type N T F Rc NPT NPTF G SJ SV J SZ VF VP S VQ VQ VQC VQC VQZ SQ VFS VFR VQ

34 Manifold with Control Unit Mounting air filter, regulator, pressure switch for air release valve on manifold as unit is possible and permits piping labor savings. Maximum number of stations depends on each kit. Refer to manifold specifications. stations are used for control unit mounting. ( station is used for E type.) Manifold Specifications ase model VVQ - VVQ - Type of connection F kit D-sub connector T kit Terminal block box L kit Lead wire C kit Connector Porting specifications, () Port size port location (P), (R), (R), () Side ottom Rc / Option Direct exhaust with silencer box C (For ø) C (For ø) C (For ø) Rc /, Rc / Rc / Note) pplicable pplicable max. stations solenoid valve F, T kit stations ( stations) L, C kit stations ( stations) Note) Manifold for mounting is included. ( ): E type Caution Plug-in type Plug Lead Type In the case of air filters with auto-drain or manual drain, mount so that the air filter is at the bottom. Control Unit Specifications ir filter (With auto-drain/with manual drain) Filtration µm Regulator Set pressure (Outlet pressure). to. MPa Pressure switch Note) Set pressure range: OFF. to. MPa Differential. MPa or less Contact a Light LED (RED) Max. switch capacity V (C), W (DC) Max. operating current m at VC, DC or less m at VC, DC ir release valve (Single only) Operating pressure range. to MPa (. to. MPa) Note) Values inside ( ) denote the low wattage (. W) specifications. Control Unit/Option () ir release valve spacer Pressure switch ISP-- Regulator with filter MP- () lanking plate Pressure switch Release Plug-in MP- V-- valve Plug lead V-- Filter element <Plug-in type> V--D <Plug lead type> V--D IN---- Note ) Rated voltage: VDC to VC Internal voltage drop: V Note ) Combination of (Single) and release valve spacer can be used as air release valve. Note ) Plug lead type can not be mounted later. How to Order Manifold VVQ Series C C C C CM Manifold Plug-in unit Plug Lead unit Stations stations Maximum and minimum number of stations depend on the kit. Cylinder port One-touch fitting for ø One-touch fitting for ø One-touch fitting for ø One-touch fitting for ø Rc / Rc / ottom ported Rc / Mixed Thread type F T C Rc G NPT/NPTF Kit () F U ir release valve coil rating Without air release valve (Only F.G type) Control unit type VC, / Hz VDC Other Control equipment ir filter with auto-drain ir filter with manual drain Regulator ir release valve Pressure switch lanking plate (ir release valve) lanking plate (Filter, Regulator) lanking plate (Pressure switch) Necessary number of manifold blocks from mounting required for mounting (Stations) Option Symbol K () N SU () W () Symbol P M MP F G C E CE-compliant Q CE-compliant Option None Special wiring specifications (Except double wiring) Name plate (pplicable to T kit) Direct exhaust with silencer box: U side exhaust IP enclosure Note ) When two or more symbols are specified, indicate them alphabetically. Example) -KN Note ) Specify wiring on the manifold specification sheet. Note ) Mounting on S and T kits is not possible. Note ) Combination with pressure switch (P and MP type) is not possible. Note ) The release valve and the pressure switch on S kit are connected to another power supply. Cable length is. m. stations stations stations stations stations stations stations station [Option] Note) Electrical entry: Control unit can not be removed except L and C kits.

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Series VQ Rubber Seal Space-saving profile Clean space saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Rubber Seal Series VQ Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),

More information

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000

More information

VQ1000. How to Order Manifold. Kit type

VQ1000. How to Order Manifold. Kit type - - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold

More information

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

How to Order Manifold. Kit type L8 B4 B6 B8 LM

How to Order Manifold. Kit type L8 B4 B6 B8 LM 0 Stations station VVQ Series VQ000 The maximum and minimum number of are varied depending on. (Refer to the table below.) Series VQ000 ase Mounted Plug-in Unit Manifold Plug-in unit 08 C Cylinder port

More information

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve CT.E- ase Mounted Type Series VQ Port Metal Seal/Rubber Seal Solenoid Valve dvanced manifold va the new age of factory au ase Mounted Type Space saving profile Clean space saving design with all pilot

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and

More information

Base Mounted Plug-in/Plug Lead: Single Unit

Base Mounted Plug-in/Plug Lead: Single Unit ase mounted VQ ase Mounted lug-in/lug Lead: Single Unit Model Number of solenoids Model Single Metal seal VQ Rubber seal VQ ouble Metal seal VQ Rubber seal VQ Closed Metal seal VQ VQ center Rubber seal

More information

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 0 PW COM Rubber Seal Port Solenoid Valve Series SZ000 Cassette Type Manifold The plug-in cassette system makes valve replacement easy. plug-in manifold has been created with a height of. mm (including

More information

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high

More information

Series VQZ1000/2000/3000 Single Unit

Series VQZ1000/2000/3000 Single Unit +- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry

More information

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications Series -SQ00 Port Solenoid Valve Plug-in Unit [Option] How to Order Manifold Electrical entry F kit D-sub connector kit P kit SSQ 08 FD Kit type Flat ribbon cable connector kit J kit Flat ribbon cable

More information

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000 D-sub Connector J Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000//000 Number of connectors: pins MIL-C-08 Conforming to JIS-X-0 --6 For details

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type20P 5 Port Solenoid Valve ody Ported Manifold ar Stock Type/Flat Ribbon Cable Series SY3000/5000/7000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 5 20P 05 Manifold series 3 SY3000

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer Base Mounted Metal Seal/Rubber Seal VQ Built-in silencer, direct exhaust Space-saving profile All pilot valves are compactly mounted on one side. The space-saving design of mounting all fittings on one

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal

More information

How to Order Manifold. Control unit Refer to pages to Kit/Electrical entry/cable length. kit (D-sub connector) U0 U1 U2

How to Order Manifold. Control unit Refer to pages to Kit/Electrical entry/cable length. kit (D-sub connector) U0 U1 U2 VQ000 ase Mounted Plug-in nit For details aout certified products conforming to international standards, visit us at www.smcworld.com. Type of connection VVQ VQ000 R port P port Port R Manifold Plug-in

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type1P Type2P 5 Port Solenoid Valve ase Mounted Manifold ar Stock Type/Flat Ribbon Cable Series /5000/000 How to Order Manifold Type 1P/Compact style SS5Y 5 1P 05 C8 Manifold series 3 5, port size Thread

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

Series SV1000/2000/3000/4000

Series SV1000/2000/3000/4000 Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double

More information

Fieldbus System (Output device for driving 5 port solenoid valves)

Fieldbus System (Output device for driving 5 port solenoid valves) Fieldbus System (Output device for driving port solenoid valves) New Compact 8mm (ctual size) Space-saving Installation IP67 RoHS EtherNet/IP added! For units with D-sub connector, and when connected to

More information

Applicable bore size. CC-Link. EtherNet/IP. Decentralized Serial Wiring. EtherCAT I/O. Serial unit: EX600 IP67 compliant. Serial unit: EX500

Applicable bore size. CC-Link. EtherNet/IP. Decentralized Serial Wiring. EtherCAT I/O. Serial unit: EX600 IP67 compliant. Serial unit: EX500 5 Port Solenoid Valve Series C000 Metal Seal Rubber Seal Compact and large flow Type (Series) Manifold pitch (mm) C000 5 6. 0.7.7 7. 0..0 to ø Note) Flow characteristics: position single, / 5/ (/ R/R)

More information

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position

More information

F Kit. D-sub. connector. D-sub. connector) Compatible network DeviceNet PROFIBUS DP. CC-Link. Compatible D-sub connector. Output

F Kit. D-sub. connector. D-sub. connector) Compatible network DeviceNet PROFIBUS DP. CC-Link. Compatible D-sub connector. Output Series VQC000 ase Mounted: Variations 5 Port Solenoid Valve Series VQC000 Sonic Conductance C[dm /(s bar)] Values: CYL EXH / 5/ Single/Double position (Closed center) pplicable bore size Compatible network

More information

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring Type4 SY000/000 ase Mounted Monifold Stacking Type/DIN ail Mounted Individual Wiring How to Order Manifold SSY 4 0 U C6 How to Order Valve Manifold ssembly Ordering example SY000 SY000 Valve stations 02

More information

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles Port Solenoid Valve: ase Mounted Metal Seal/Rubber Seal Series VQ Space and capacity saving Pilot valve is gathered at one side. Space saving design which does not have any protrusions. Space saving Capacity

More information

Plug Lead Unit: Flip Type

Plug Lead Unit: Flip Type Series ody orted lug Lead Unit: Flip Type For details about certified products conforming to international standards, visit us at www.smcworld.com. 0 Series Kit/Electrical entry/cable length F kit (D-sub

More information

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308 Cable ppendix Cable ppendix Multi-way cables The multi-pole connector cables used on SMC valves are common across several ranges. Cables are available in accordance with the MIL standard C-08 and also

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

Series SY3000/5000 How to Order Manifold

Series SY3000/5000 How to Order Manifold Type N ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN Rail Mounted/Connector ox SY/ How to Order Manifold SSY SY SY Specifications Symbol Specifications With connector box (COM spec.) N With

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve ubber Seal / ort Solenoid Valve Series 000 / 000 / 000 [Option] SJ SY SV SZ V S000 VQ VQ VQ VQC VQZ SQ VFS VF VQ Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to

More information

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I ISO Standard Solenoid Valve Series VQ7-6/7-8 (Size ) (Size ) Conforms to ISO Standard /I.0- Ideal for driving cylinders up to Large flow capacity ø00 (VQ7-6, Size ) ø60 (VQ7-8, Size ) Nl/min VQ7-6: 668.

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection Rubber Seal Port Solenoid Valve Series SJ000/000 Cassette Type Manifold 0 mm 7. mm (SJ000) 0 mm (SJ000) Non plug-in type Individual wiring manifold SJ000 SJ000 Can be mounted together. Connecter connection

More information

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles ort Solenoid Valve: ase Mounted Metal Seal/Rubber Seal Series Space and capacity saving ilot valve is gathered at one side. Space saving design which does not have any protrusions. Space saving Capacity

More information

Example. U side. Stations SY5000

Example. U side. Stations SY5000 45 Type 5 ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN ail Mounted/Individual Wiring Series SY3000/5000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 3 45 05 U C6 Example

More information

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Body Ported Base Mounted Series S000 S000 S000 S000 S000 S4000 S5000 Sonic conductance C [dm /s bar)] 4/ 5/(A/B R/R) Single Double.8.4

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

Manifold Specifications Stacking Type

Manifold Specifications Stacking Type Specifications Stacking Type Keeps environmental air clean from pilot exhaust Use of the VV5FS- manifold can exhaust intensively the pilot exhaust gas to the base side, and can prevent environmental aggravation

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model 2 position 3 position

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3

More information

Manifold Specifications

Manifold Specifications Specifications Specifications Base mounted VVFR-01 VVFR- VVFR-0 Wiring With terminal block With multi-connector With D-sub connector Grommet terminal DIN terminal Grommet Grommet terminal Conduit terminal

More information

How to Order Manifold. Option Symbol

How to Order Manifold. Option Symbol Series Plug Lead nit For details about certified products conforming to international standards, visit us at www.smcworld.com. Series/Manifold 12 Stations 01 1 station Kit/Electrical entry/cable length

More information

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type. Series -S00 ompact Direct Operated Port Solenoid Valve ontrol Valves ase mounted ody ported lean Series lean Series V S R oil voltage 24 VD VD VD VD VD Power consumption Pressure specification Flow rate

More information

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Vacuum Release Valve with Restrictor Series SJ3A6 SJ Plug-in Type Connector Connection P.86 D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Non Plug-in Type Individual

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR2 JIS Symbol type

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

0.35 W (Without light)

0.35 W (Without light) Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

5 Port Solenoid Valve Plug Lead Type

5 Port Solenoid Valve Plug Lead Type 5 Port Solenoid alve Plug Lead Type Series Body Ported Flow rate characteristics For single/double solenoid C [dm 3 /(s bar)]: 0.6 Single Unit alve width: 7.4 mm Possible to drive cylinders: Up to ø32

More information

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is. Port Solenoid Valve Series VQ 00 Unprecedented high speed, stable response, and extra-long service life. ON:.ms, OFF: ms, Dispension accuracy ±ms (With indicator light and surge voltage suppressor; supply

More information

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating / ort Solenoid Valve ubber Seal Series SYJ000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Specifications JIS Symbol port port (manifold) position

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 044 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000 racket

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry TEX Compliant Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 44 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000

More information

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000) 5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust

More information

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A Type N SY/ ase ounted anifold Stacking Type/DIN Rail ounted Connector ox How to Order anifold SSY SY SY Specifications Symbol Specifications With connector box (CO spec.) N With connector box ( CO spec.)

More information

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot 3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in

More information

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series VZS Series Variations Plug-in Type Base Mounted Type (With sub-plate) Non Plug-in Type Base Mounted Type (With sub-plate) Series Sonic conductance

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series

More information

Fieldbus System (Gateway Decentralized Type)

Fieldbus System (Gateway Decentralized Type) Fieldbus System (Gateway Decentralized Type) * * Except the SY, VQC and S0700 valves GW Unit which supports PROFINET added. New M connector type Input Unit added. Decentralized valve installation Valves

More information

Non-Contact Sensor for Workpiece Placement Verification

Non-Contact Sensor for Workpiece Placement Verification ir Catch Sensor Series 2 Non-Contact Sensor for Workpiece Placement Verification Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact

More information

Manifold Specifications

Manifold Specifications Specifications Plug-in Type: With Terminal Block Since lead wires of solenoid valve are connected with the terminals on upper surface of terminal block, corresponding lead wires from power source can be

More information

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Soft Start-up Valve. AV2000/3000/4000/5000 Series Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off

More information

3 Port Air Operated Valve

3 Port Air Operated Valve Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation

More information

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1 Port Solenoid Valve Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Non plug-in manifold 0 0 S 60 Stations stations 0 stations SUP/EXH

More information

Terminal Block Box (Spring Type) SY3000/5000/7000 Series

Terminal Block Box (Spring Type) SY3000/5000/7000 Series INFORMATION 5 ort olenoid alve Terminal lock ox (pring Type) Y3000/5000/7000 eries Compact RoH Height 6.7 mm shorter (Approx. 9% reduction) Installation area of the terminal block box Reduced by approx.

More information

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing

More information

New Concept Connector Type Manifold

New Concept Connector Type Manifold New Concept Connector Type Manifold Series /000/3000/000 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration.

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Rubber Seal Port Solenoid Valve Series Manifold Single Unit ase Mounted Manifold VV01 V100 ar base P.18 ody Ported P.10 ase Mounted P.10 VQD VKF VK VT VS Separable base ody Ported Manifold P.1 Stacking

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M. V3 Cover

More information

Vacuum System Peripherals

Vacuum System Peripherals Vacuum System Peripherals Vacuum Regulator/Electronic Vacuum Regulator Vacuum regulator: IRV0/0 Electronic vacuum regulator: ITV009/ITV09 Directional Control Valve Selection guide of directional control

More information

5 Port Air Operated Valve

5 Port Air Operated Valve Port ir Operated Valve Series VF000/000/000 RoHS 22- Series VF000/000/000 Model Selection by Operating Conditions q ir Operated Valve: Single Unit Series Sonic conductance C[dm /(s bar)] Type of actuation

More information

Series PCW. PC Wiring System

Series PCW. PC Wiring System CT.ES0-0 PC Wiring System Series PCW The PC wiring system is a revolutionary new system that simplifies wiring between a PLC and all types of connected equipment. revolutionary new wiring system... 4VDC

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes

More information

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold Port Solenoid Valve VV00 Series Highly Integrated Unit Manifold po ted - pera irect-o d station es on rt valv ally ividu Ind wired n be ve ca val d. adde ector Con-inn connection) lug (For p ø connection

More information

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal Port Solenoid Valve Cassette Type Manifold Rubber Seal 7.mm (SJ000) SJ000 SJ000 Can be mounted together. 0mm (SJ000) Connector connection New New cable type manifold is added! New Additional options are

More information

Rubber Seal VP300/500/700

Rubber Seal VP300/500/700 Port Pilot Operated Poppet Rubber Seal 00/500/700 High flow capacity Cv1.0 (00), Cv. (500), Cv.0 (700) Low power consumption: 1.8W(DC) Possible to use as either selector valve or divider valve Changeable

More information