5 Port Solenoid Valve

Size: px
Start display at page:

Download "5 Port Solenoid Valve"

Transcription

1 0 PW COM Rubber Seal Port Solenoid Valve Series SZ000 Cassette Type Manifold The plug-in cassette system makes valve replacement easy. plug-in manifold has been created with a height of. mm (including DIN rail). Valve replacement can be performed easily. Moreover, since spare terminates for wiring (receptacle housings) are contained inside the manifold, terminal changes (additions) can be performed quickly and easily. (The number of additional stations is limited by the manifold specifications. For details, refer to page.) Valves equipped with switches djustment and maintenance of equipment can be performed with greater safety, since the power to each valve can be shut off individually with built-in switches. High speed response of 0 ms SZ000 double, 0. MPa VDC, Without surge Low power consumption and a faster response time of 0 ms are obtained with a unique pilot valve construction. Low power consumption: 0. W (Current draw: m at VDC) Low power consumption enables direct operation by a PLC. Cost savings are realized through the use of a smaller power supply and the elimination of relay cards. Easy attaching/detaching of the tubing The interval between ports and is a wide 0. mm, allowing easy changes of fittings and tubing. The connector entry direction can be changed from top to side with a simple operation. Switch for locking a connector LOCK High reliability and long service life exceeding 0 million cycles or more High reliability and long service life have been achieved with guide ring construction which prevents eccentricity of the main valve, and a return piston with increased return force. (Single and double solenoid type) FREE SJ SY SV SYJ SZ VP S000 VQ VQ VQ VQC VQZ SQ VFS VFR VQ C/C C/C (Elbow type) Size and weight reduced by eliminating the manifold base LOCK Series SZ000 FREE port port M port block assembly Height Weight % reduction % reduction (Compared with SX000- with DIN rail manifold and stations) Plug-in Type LOCK FREE P. EX0/Serial transmission system P. Non Plug-in Type P. EX0/Serial transmission system LOCK FREE P. Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

2 Port Solenoid Valve Series SZ000 Plug-in Type How to Order Plug-in manifold with power supply terminals SSZ 0 F D 0 U P CE-compliant Connector type Q CE-compliant F: D-sub connector ( pins) LOCK FREE PG: Flat ribbon cable (0 pins) LOCK FREE P: Flat ribbon cable ( pins) LOCK FREE PH: Flat ribbon cable (0 pins) LOCK FREE SUP/EXH block mounting position U U side ( to 0 stations) D ( to 0 stations) oth sides ( to 0 stations) M * Special specifications * For special specifications, indicate separately by the manifold specification sheet. Note) total of up to SUP/EXH blocks can be mounted. Please contact SMC if or more will be mounted. R Pilot type Internal pilot External pilot Power supply terminals Symbol Specifications P VDC, Positive common P VDC, Positive common N VDC, Negative common N VDC, Negative common SUP/EXH block fitting specifications L Option When a longer DIN rail is desired than the specified stations, specify the station number to be required. Straight Elbow fittings (Upward) Elbow fittings (Downward) Valve stations Connector mounting position Symbol Mounting position D F: D-sub connector Symbol Stations 0 stations stations stations 0 stations Note Double wiring specifications () Specified layout () (Up to solenoids possible) P: Flat ribbon cable connector ( pins) Symbol 0 Stations stations Note 0 0 stations stations 0 stations Double wiring specifications Specified layout (Up to solenoids possible) Connector entry direction : Perpendicular connector : Lateral connector LOCK FREE LOCK FREE PG: Flat ribbon cable connector (0 pins) Symbol Stations Note 0 stations 0 0 stations stations stations Double wiring specifications Specified layout (Up to solenoids possible) PH: Flat ribbon cable connector (0 pins) Symbol Stations Note 0 stations stations stations stations Double wiring specifications Specified layout (Up to solenoids possible) Note ) Double wiring specifications: Single, double, position and position solenoid valves can be used at all of the manifold stations. Note ) Specified layout: Indicate wiring specifications on a manifold specification sheet. (Please note that in locations where single solenoid wiring is indicated, it will be impossible to use double or position/ position valves.) Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

3 Cassette Type Manifold Series SZ000 How to Order Plug-in manifold without power supply terminals SSZ 0 F D 0 U Connector type F: D-sub connector ( pins) LOCK FREE PG: Flat ribbon cable (0 pins) LOCK FREE LOCK FREE P: Flat ribbon cable ( pins) LOCK FREE PH: Flat ribbon cable (0 pins) LOCK FREE Connector mounting position Symbol D Mounting position Connector entry direction : Perpendicular connector : Lateral connector LOCK FREE Valve stations SUP/EXH block mounting position U U side ( to 0 stations) D ( to 0 stations) oth sides ( to 0 stations) M Special specifications For special specifications, indicate separately by the manifold specification sheet. Note) total of up to SUP/EXH blocks can be mounted. Please contact SMC if or more will be mounted. F: D-sub connector Symbol Stations 0 stations 0 0 Note PG: Flat ribbon cable connector (0 pins) Symbol Stations Note 0 stations stations stations 0 stations 9 stations stations 9 stations Double wiring specifications () Specified layout () (Up to solenoids possible) Double wiring specifications Specified layout (Up to 9 solenoids possible) Pilot type R Option When a longer DIN rail is desired than the specified stations, specify the station number to be required. SUP/EXH block fitting specifications L Internal pilot External pilot Straight CE-compliant Q Elbow fittings (Upward) Elbow fittings (Downward) CE-compliant P: Flat ribbon cable connector ( pins) Symbol 0 Stations stations Note 0 0 PH: Flat ribbon cable connector (0 pins) Symbol Stations Note 0 stations stations stations 0 stations stations stations 9 stations Double wiring specifications Specified layout (Up to solenoids possible) Double wiring specifications Specified layout (Up to 9 solenoids possible) Note ) Double wiring specifications: Single, double, position and position solenoid valves can be used at all of the manifold stations. Note ) Specified layout: Indicate wiring specifications on a manifold specification sheet. (Please note that in locations where single solenoid wiring is indicated, it will be impossible to use double or position/ position valves.) SJ SY SV SYJ SZ VP S000 VQ VQ VQ VQC VQZ SQ VFS VFR VQ Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

4 ON SMC Series SZ000 How to Order How to order solenoid valves For plug-in (Common for both with and without power supply terminals) SZ 0 LOZ C Type of actuation position single solenoid C () () () () () () (E)(P)(E) position double solenoid () (E)(P)(E) position closed center () () (E)(P)(E) position exhaust center () () (E)(P)(E) position pressure center () () (E)(P)(E) position dual port valve: N.C./N.C. () SOL.a SOL.b (R) (R) (P) position dual port valve: N.O./N.O. SOL.a SOL.a (R) (R) SOL.b (P) SOL.b (P) () (R) position dual port valve: N.C./N.O. () (R) Rated VDC VDC When using on a manifold with power supply terminals, be sure to match with the manifold s specifications. ack pressure check valve None K uilt-in The built-in back pressure check valve type has an effective area approximately 0% smaller. The position valve is not available with back pressure check valve. Pilot type Internal pilot R External pilot The position dual port valve is not available with external pilot specifications. : Non-locking push type Rated : Without switch J: With switch For switch operation, refer to page 9. Common specifications Positive common N Negative common When using on a manifold with power supply terminals, be sure to match with the manifold s common specifications. Manual override D: Push-turn locking slotted type, port size C: for ø C: for ø M: M x 0. CE-compliant Q CE-compliant Mede to Order Main Valve Fluoro Rubber Specifications X90 (Refer to page 9) Elbow fitting assembly (Upward) L: ø elbow fitting assembly L: ø elbow fitting assembly Elbow fitting assembly (Downward) : ø elbow fitting assembly : ø elbow fitting assembly 0 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

5 LOCK FREE Cassette Type Manifold Series SZ000 How to Order Valve Manifold ssembly Ordering example (SZ000, positive common with power supply terminals) Double solenoid ( VDC) SZ0-LOZ-C ( sets) SUP/EXH block (U side mounting) Single solenoid ( VDC) SZ0-LOZ-C ( sets) With power supply terminals Plug-in manifold SSZ-0PD-0U-P Stations U side SJ SY SV SYJ Made to Order (Refer to page 9 for details.) Manifold Specifications Model Manifold (P: SUP), / (R: EXH) system Valve stations (With power terminal) pplicable connector Internal wiring (), () port Location Porting specification Direction (P), / (R) port Port size (), () port SSZ-0PD-0U-P set (Manifold part number) SZ0-LOZ-C sets (Single solenoid part no.) SZ0-LOZ-C sets (Double solenoid part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Stations are counted from as the st one. Indicate the valves to be attached below the manifold part number, in order starting from station as shown in the drawing. When entry of part numbers becomes complicated, indicate on the manifold specification sheet. D-sub connector Type 0F D-sub connector Conforming to MIL-C-0 JIS-X-0 Type 0P Flat ribbon cable type 0P Plug-in type Common SUP, EXH to 0 stations to stations to stations Flat ribbon cable connector Socket: pins MIL type with strain relief Conforming to MIL-C-0 + COM, COM Valve Lateral, Upward, Downward C C, C, M Type 0PG Flat ribbon cable connector Socket: 0 pins MIL type with strain relief Conforming to MIL-C-0 Type 0PH Flat ribbon cable connector Socket: 0 pins MIL type with strain relief Conforming to MIL-C-0 Weight W (g) () n: Stations W =.n + n + m +. n: Number of SUP/EXH blocks m: Weight of DIN rail Note ) In cases such as those where many valves are operated simultaneously, use type (double side SUP/EXH), applying pressure to the (P) ports on both sides and exhausting from the (R) ports on both sides. Note ) The weight W is the value for the D-sub connector manifold with power supply terminals only. To obtain the weight with solenoid valves attached, add the solenoid valve weights given on page for the appropriate number of stations. For DIN rail weight, refer to page. SZ VP S000 VQ VQ VQ VQC VQZ SQ VFS VFR VQ Flow Characteristics Port size,, (P, E, E) C, (, ) C C b Flow characteristics M Note) The value is for manifold base with stations and individually operated position type. Values inside [ ] are for position dual port valves. Cv b Cv Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

6 Series SZ000 Solenoid Valve Specifications Series Fluid Internal pilot position single operating position double pressure range (MPa) position position dual port valve External pilot Operating pressure range operating Pilot position single pressure range pressure position double (MPa) range position mbient and fluid temperature ( C) position single position double position position dual port valve Weight Valve model SZ 0- -C SZ 0- -C SZ 0- -M Type of actuation SZ000 ir 0. to to to to kpa to to to to 0. 0 to 0 (No freezing. Refer to page.) position single, double Max. operating position dual port valve 0 frequency (Hz) position Manual override (Manual operation) Non-locking push type, Push-turn locking slotted type Pilot type Common exhaust type for main and pilot valve Lubrication Not required Mounting orientation Unrestricted Impact/Vibration resistance m/s Note) 0/0 Enclosure Dust-protected Note) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and deenergized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Solenoid Specifications Electrical entry L type (For plug-in), M type plug connector (M) Rated coil (V) Note),,,, VDC llowable fluctuation ±0% of rated Power consumption (W) 0. (With light: 0.) Surge Diode Indicator light LED Note) Only VDC and VDC are available for plug-in use. Response Time Note) ased on dynamic performance test, JIS -9. (Coil temperature: 0 C, at rated ) Response time (ms) (at the pressure of 0. MPa) Type of actuation Without surge position position position position position position position position position or less 0 or less or less 0 or less Single Double Closed center Exhaust center Pressure center Dual port valve Single Double Closed center Exhaust center Pressure center Dual port valve Single Double Closed center Exhaust center Pressure center Dual port valve With surge S, Z type or less or less 0 or less or less Port size (), () C for ø C for ø M x 0. Mass (g) Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

7 Cassette Type Manifold Series SZ000 Manifold Option SUP block disk y installing a SUP block disk in the pressure supply passage of a manifold valve, it is possible to supply two or more different high and low pressures to one manifold. (Use in combination with a pilot port block disk.) lanking block assembly SZ000-- These are mounted when later addition of valves is planned, etc. Series SZ000 Part no. SZ000-- EXH block disk y installing an EXH block disk in the exhaust passage of a manifold valve, it is possible to divide the valve s exhaust so that it does not affect another valve. (Two block disks are needed to divide both exhausts.) Label for block disk SZ000-- Series SZ000 Series SZ000 Part no. SZ000-- Pilot port block disk y installing a pilot port block disk in the pilot passage of a manifold valve, it can be function as an internal pilot/external pilot mixed manifold. Label for SUP/EXH block disk Label for EXH block disk Part no. SZ000-- The labels shown below are used on manifold stations containing SUP/EXH block disk(s) to show their location. ( pcs. each) Label for SUP block disk Label for pilot port block disk When a block disk is concurrently ordered by specifying on the manifold specification sheet, etc., a label will be stuck on the position where block disk is mounted. Silencer with This silencer can be mounted on the manifolds port R (exhaust) with a single touch. C Series SZ000 (ø) Dimensions pplicable fittings size ød ød Plug (White) Model N0-KM L Model L D KQP-0 KQP-0 KQP-0 Effective area mm ø These are inserted in cylinder ports or SUP/EXH ports which are not being used. Purchasing order is available in units of 0 pieces. 0. ød 9 C 0 SJ SY SV SYJ SZ VP S000 VQ VQ VQ VQC VQZ SQ VFS VFR VQ LOCK FREE Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

8 Series SZ000 Manifold Option DIN rail dimensions/mass VZ Refer to the L dimension tables Enter a number from the DIN rail dimension table below. L (.) D-sub connector ( pins)/cable assembly XT00-DS L. () ().0 SMC No. L dimension Mass (g) No. L dimension Mass (g) No. L dimension Mass (g) XT00-FC - to W Flat Ribbon Cable ssembly Cable length (L). m m m Connector width (W) Rail mounting hole pitch pins XT00-FC0- XT00-FC0- XT00-FC0-. (.) L pins XT00-FC0- XT00-FC0- XT00-FC Flat ribbon cable type/cable assembly Terminal no. Triangle mark position Red pins XT00-FC- XT00-FC- XT00-FC-. For other commercial connectors, use a type with strain relief conforming to MIL-C-0. Connector manufacturers example Hirose Electric Co., Ltd. Sumitomo M Limited Fujitsu Limited Japan viation Electronics Industry, Ltd. J.S.T. Mfg. Co., Ltd. Terminal no. Cable length (L). m m m Socket side Terminal no. Lead wire color lack rown Red Orange Yellow Pink lue Purple 9 Gray 0 White White Yellow Orange Yellow Pink lue Purple Gray 9 Orange 0 Red rown Pink Gray lack White D-sub Connector Cable ssembly ssmbly part no. XT00-DS-0 XT00-DS-00 XT00-DS-00 x M. x 0. D-sub Connector Cable ssembly Terminal No. Dot marking None None None None None None None White lack lack Red Red Red lack lack White None None lack White White Red Red White None Note Cable cores x WG For other commercial connectors, use a pins type with female connector conforming to MIL-C- 0. Connector manufacturers example Hirose Electric Co., Ltd. Fujitsu Limited Japan viation Electronics Industry, Ltd. J.S.T. Mfg. Co., Ltd. Multi-core vinyl cable 0. mm x C Electric Characteristics Item Characteristics or less Voltage limit VC, min. 000 or less Note) The minimum bending radius for D-sub connector cables is 0 mm. Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

9 Cassette Type Manifold Series SZ000 Manifold Electrical Wiring Type 0F D-sub Connector Type ( pins) Without Power Supply Terminal With Power Supply Terminal Positive common Negative common Common Station Station Station Station Type 0P Flat Ribbon Cable Type ( pins) Without Power Supply Terminal Common Station Triangle mark 0 Positive common Positive pin (Common) Negative pin With Power Supply Terminal Positive pin (Common) Negative pin Station Triangle mark 0 Positive pin Negative common Negative pin (Common) The common polarity should be the same as the common specifications of the valve to be used. The maximum number of stations that can be Power supply terminal Power supply terminal accommodated is 0 manifold stations, with up to solenoids. The maximum number of stations that can be accommodated is 0 manifold stations, with up to solenoids. The circuits above are for the double wiring specifications with up to 0 or stations. Connect to in the case of a single solenoid. Moreover, when wiring instructions are given on a manifold specification sheet, the signal for single and the, signals for double should be wired in order,,,...etc., without skipping or leaving any connectors remaining. Stations are counted from as the st one. Station Station Station Station 0 Station Station Station Station Station 0 Station Station Positive pin Negative pin (Common) Station Station Station Triangle mark SJ SY SV SYJ SZ VP S000 VQ VQ VQ VQC VQZ SQ VFS VFR VQ The common polarity should be the same as the common specifications of the valve to be used. Power supply terminal Power supply terminal The maximum number of stations that can be accommodated is 0 manifold stations, with up to solenoids. The maximum number of stations that can be accommodated is 0 manifold stations, with up to solenoids. The circuits above are for the double wiring specifications with up to or stations. Connect to in the case of a single solenoid. Moreover, when wiring instructions are given on a manifold specification sheet, the signal for single and the, signals for double should be wired in order,,,...etc., without skipping or leaving any connectors remaining. Stations are counted from as the st one. Since terminal numbers are not indicated on the flat cable, use the triangle mark as a reference for wiring. Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

10 Series SZ000 Manifold Electrical Wiring Type 0PG Flat Ribbon Cable Type (0 pins) Without Power Supply Terminal With Power Supply Terminal Positive common Negative common 0 Common 0 Positive pin (Common) 0 Positive pin 9 Station 9 Station 9 Negative pin Station 9 Negative pin (Common) Station Station Station Station Station Triangle mark Station Triangle mark Station Triangle mark The common polarity should be the same as the common specifications of the valve to be used. The maximum number of stations that can be accommodated is 9 manifold stations, with up to 9 solenoids. Power supply terminal Power supply terminal The maximum number of stations that can be accommodated is manifold stations, with up to solenoids. The circuits above are for the double wiring specifications with up to or 9 stations. Connect to in the case of a single solenoid. Moreover, when wiring instructions are given on a manifold specification sheet, the signal for single and the, signals for double should be wired in order,,,...etc., without skipping or leaving any connectors remaining. Stations are counted from as the st one. Since terminal numbers are not indicated on the flat cable, use the triangle mark as a reference for wiring. Type 0PH Flat Ribbon Cable Type (0 pins) Without Power Supply Terminal With Power Supply Terminal Positive common Negative common 0 9 Common 0 9 Positive pin (Common) Negative pin 0 9 Positive pin Negative pin (Common) Station Station Station Station Station Station Station Triangle mark Station Triangle mark Station Triangle mark The common polarity should be the same as the common specifications of the valve to be used. The maximum number of stations that can be accommodated is 9 manifold stations, with up to 9 solenoids. Power supply terminal Power supply terminal The maximum number of stations that can be accommodated is manifold stations, with up to solenoids. The circuits above are for the double wiring specifications with up to stations. Connect to in the case of a single solenoid. Moreover, when wiring instructions are given on a manifold specification sheet, the signal for single and the, signals for double should be wired in order,,,...etc., without skipping or leaving any connectors remaining. Stations are counted from as the st one. Since terminal numbers are not indicated on the flat cable, use the triangle mark as a reference for wiring. Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

11 Cassette Type Manifold Series SZ000 Wiring of Plug-in Type Manifold with Power Supply Terminal (Example) Since the power supply to drive valves with power supply terminals can be supplied from either the control side or the manifold side, these wiring examples should be used for reference when wiring is performed.. Wiring example when using manifold power supply terminal PLC (Programmable Logic Controller) Manifold valve (SSZ-0PGD-0U- ). Wiring example when not using manifold power supply terminal (Power is supplied to the control side or along the wiring, etc.) PLC (Programmable Logic Controller) Manifold valve (SSZ-0PGD-0U- ) DC power supply Solenoid Valve DC power supply SZ manifold internal wiring (Flat ribbon cable, Positive common specifications) 0 9 Negative pin Power supply terminal Power supply 0 Positive pin 9 Triangle mark SZ manifold internal wiring (Flat ribbon cable, Positive common specifications) Control side (PLC, etc.) (NPN open collector output) COM Cable assembly XT00-FC0-, etc. Power supply Control side (PLC, etc.) (NPN open collector output) COM SJ SY SV SYJ SZ VP S000 VQ VQ VQ VQC VQZ SQ VFS VFR VQ Solenoid Valve Power supply terminal Triangle mark Cable assembly XT00-FC0-, etc. Caution Single wire, COM position, etc. of PLC are different from each manufacturer. When connecting with PLC, read the specifications carefully and understand the electrical circuit. Poor wiring could cause damage to PLC, power source, etc. as well as manifold and valve. Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

12 Series SZ000 Construction JIS Symbol position single position single with () () back pressure check valve () () position single r e w t y q u!0 o (E) (P)(E) (E) (P)(E) () () JIS Symbol position double () () (E) (P)(E) JIS Symbol position closed center position double with back pressure check valve () () (E) (P)(E) position double (E) (P) (E) r e w t y q u!0 o i () () () () (E) (P)(E) position exhaust center (E) (P) (E) i () () position closed center/exhaust center/pressure center (E) (P)(E) r e w t y q u!0 o position pressure center () () () (E) (P)(E) () (E) (P) (E) i Component Parts No. Description Material Note ody Zinc die-casted dapter plate Resin Urban white Pilot body Resin Urban white Molded coil Urban gray ody cover Resin Urban white Spool valve assembly luminum/hnr Port block Resin Urban white ottom cover assembly Urban white Replacement Parts No. Description Part no. 9 Refer to part number information on page 9. 0 Clip SX000-- position single with back pressure check valve r e w t y q u!0 o (E) (E) (P) i () () Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

13 Cassette Type Manifold Series SZ000 JIS Symbol position dual port valve SZ0 [N.C. valve x pcs.] () () SZ0 [N.C. valve x pcs.] y t r u q q e i!!0 SOL.a (R) SOL.b (R) (P) SZ0K/With back pressure check valve () () SOL.a (R) SOL.b (R) (P) SZ0 [N.C. valve x pcs.] () () SOL.a (R) SOL.b (R) (P) SZ0K/With back pressure check valve () () SOL.a (R) SOL.b (R) (P) SZC0 [N.C. valve, N.O. valve pc. each] () () SOL.a (R) SOL.b (R) (P) SZC0K/With back pressure check valve () () SOL.a (R) SOL.b (R) SZ0 [N.O. valve x pcs.] (R) (R) (P) y t r u w w e i!!0 (R) (R) (P) SZC0 [N.C. valve, N.O. valve pc. each] y t r u q w e i!!0 o o SJ SY SV SYJ SZ VP S000 VQ VQ VQ VQC VQZ SQ VFS VFR VQ (P) (R) (P) (R) o Component Parts No. 9 Replacement Parts No. 0 Description Spool valve assembly Spool valve assembly ody dapter plate Pilot body Molded coil ody cover Port block ottom cover assembly Description Clip Material Resin/HNR Resin/HNR Zinc die-casted Resin Resin Resin Resin Note For N.C. (Normally closed) For N.O. (Normally open) Urban white Urban white Urban gray Urban white Urban white Urban white Part no. Refer to part number information on page 9. SX000-- SZ0K/With back pressure check valve y t r u q q e i!!0 (E) (E) (P) o Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

14 Series SZ000 Manifold Exploded View Type 0P Manifold (Plug-in, flat ribbon cable type) w q U side t r u e Component Parts No. Description Part no. SUP/EXH block assembly SZ End block assembly Housing holder SUP block bush assembly SUP block bush assembly DIN rail Connector block assembly SZ000-- SX000-- SZ000-- SZ000-- VZ SZ000-- Note C: With for ø C: With for ø L: With for ø (Elbow fetching upward) L: With for ø (Elbow fetching upward) : With for ø (Elbow fetching downward) : With for ø (Elbow fetching downward) Refer to page. Refer to connector block assembly part no. table below. y Connector lock ssembly Part No. Connector specifications Mounting position Part no. Without power supply terminals With power supply terminals Note For D-sub connector For flat ribbon cable pins SZ SZ D D P N SZ D - P N SZ D - : Perpendicular connector : Lateral connector P: Positive common N: Negative common For flat ribbon cable 0 pins For flat ribbon cable 0 pins For serial SZ SZ SZ D D D P N SZ D - P N SZ D - Note) The assembly part numbers with power supply terminals are VDC specifications. If VDC specifications are required, enter at the end of the assembly part number. Note) Connector block assembly can be shipped as an assembly only in the case of double wiring. Since the possible number of stations differs depending on the connector type, refer to the valve station section on catalog pages, 9, and, and enter the number of stations in the section of the assembly part number. Please contact SMC if a connector block assembly is required having a wiring specification other than double wiring. 0 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

15 Cassette Type Manifold Series SZ000 Plug-in Manifold Station Expansion Caution In addition to solenoid valves, housing holders (SX000--) are necessary for expansion of manifold stations. Double wiring specifications manifolds which do not have the maximum number of stations, contain spare receptacle housings for expansion in the housing holder of the last station, or inside the supply/exhaust block assembly (for a maximum of stations). When expanding stations, perform the disassembly and assembly of the manifold while referring to the expansion method shown below. () Loosen the DIN rail holding screw if the end block on the U side. Receptacle housing U side End block SUP/EXH block Contains receptacle housings for expansion Housing holder (SX000--) Use caution to the bushes for junction not to fall.. lign connectors. () () () Separate the end block and SUP/EXH block. Take out the receptacle housing for expansion which is inside the SUP/EXH block, attach it to the newly added housing holder, and attach to the manifold. (Numbers are displayed on the side of the receptacle housings, and they should be used in order from the lowest number.) Mount the valve on the DIN rail.. ttach to rail by pushing on coil area.. Hook on rail. SJ SY SV SYJ SZ VP S000 VQ VQ VQ VQC VQZ SQ VFS VFR VQ () While pressing the manifold together from both sides, refasten the side U end block s DIN rail holding screw. Caution (Tightening torque:. N m) Press the manifold. Press the manifold. Caution.e sure to shut off the power and air supplies before disassembly. Furthermore, since air may remain inside the actuator, piping and manifold, confirm that the air is completely exhausted before performing any work..when disassembly and assembly are performed, air leakage may result if connections between blocks and tightening of the end block s holding screw, is inadequate. efore supplying air, confirm that there are no gaps, etc. between blocks, and that manifold blocks are securely fastened to the DIN rail. Then supply air and confirm that there is no air leakage before operating..note that for manifolds specified with other than double wiring, spare receptacle housings for expansion are not included unless indicated at the time of order. Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

16 Series SZ000 Dimensions: SZ000 Plug-in SSZ-0FD - Stations U-. (Pitch) P=0. [(), () port] pplicable tubing O.D.: ø ø With external pilot. FREE R... [(P), (R) port] pplicable tubing O.D.: ø P PE M x 0. [(), () port] (X, PE ports) pplicable tubing O.D.: ø X P R pplicable connector: JIS-X-0 MIL-C-0 D-sub equivalent L (L). Switch for locking a connector (.). LOCK Terminal no.. DIN rail.9 Manual override Press and turn for the locking type.. (): Orange (): Green L (Rail mounting hole pitch.) L DIN rail holding screw Power supply terminals (M terminal screws). (With switch mounted). The indication marking is for VDC. (Station n) (Station ) side: Orange side: Green.9. ON ON (.) (DIN rail dimension). (9.) Note) For manifold dimensions with elbow fitting, refer to page. Switch (When equipped with switch) Internal Pilot Manifold L Dimension L n L L L L n: Stations External Pilot Manifold L Dimension L n L L L L n: Stations Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

17 Cassette Type Manifold Series SZ000 Dimensions: SZ000 Plug-in SSZ-0FD - Stations -. (Pitch) P=0. [(P), (R) port] pplicable tubing O.D.: ø With external pilot. (.) 0. [(), () port] pplicable tubing O.D.: ø ø.... DIN rail side: Orange side: Green. R P L R P M x 0. [(), () port] Switch for locking a connector (Station n) (Station ) ON ON. Manual override Press and turn for the locking type. (): Orange (): Green L (Rail mounting hole pitch.) L FREE LOCK (L).9. (.) (DIN rail dimension). (9.). (X, PE ports) pplicable tubing O.D.: ø DIN rail holding screw Power supply terminals (M terminal screws)... (With switch mounted) R PE X P pplicable connector: Terminal no..9. R P JIS-X-0 MIL-C-0 Note) For manifold dimensions with elbow fitting, refer to page.. The indication marking is for VDC. D-sub equivalent SJ SY SV SYJ SZ VP S000 VQ VQ VQ VQC VQZ SQ VFS VFR VQ Switch (When equipped with switch) Internal Pilot Manifold L Dimension L n L L L L n: Stations External Pilot Manifold L Dimension L n L L L L n: Stations Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

18 Series SZ000 Dimensions: SZ000 Plug-in SSZ-0FD - Stations U- ( pins). (Pitch) P=0. M x 0. [ (), () port] With external pilot. X P PE R FREE P R.. [(P), (R) port] pplicable tubing O.D.: ø [(), () port] pplicable tubing O.D.: ø ø (X, PE ports) pplicable tubing O.D.: ø. L Switch for locking a connector. (L) (.).. LOCK... pplicable connector: pins MIL type With strain relief (Conforming to MIL-C-0) DIN rail Manual override Press and turn for the locking type. (): Orange (): Green L (Rail mounting hole pitch.) L (Station n) (Station ). DIN rail holding screw Power supply terminals (M terminal screws) 0.. (When equipped with switch) Triangle mark.9 pplicable connector: 0 pins MIL type With strain relief (Conforming to MIL-C-0).. The indication marking is for VDC. Triangle mark position pplicable connector: 0 pins MIL type With strain relief (Conforming to MIL-C-0) side: Orange side: Green.9 Internal Pilot Manifold L Dimension L n L L L L ON ON (.) (DIN rail dimension). n: Stations (.) Switch (When equipped with switch) 0PG (0 pins) 0PH (0 pins) Note ) Types 0PG and 0PH differ only in their connectors, and the L through L dimensions are the same as type 0P. Note ) For manifold dimensions with elbow fitting, refer to page. External Pilot Manifold L Dimension L n L L L L Triangle mark position Triangle mark position n: Stations Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

19 Cassette Type Manifold Series SZ000 Dimensions: SZ000 Plug-in SSZ-0FD - Stations - ( pins). (Pitch) P=0. M x 0. [(), () port] [(P), (R) port] pplicable tubing O.D.: ø. With external pilot (.). 0.. DIN rail.. R P [(), () port] pplicable tubing O.D.: ø ø L Switch for locking a connector R P (Station n) (Station ) side: Orange side: Green.. FREE LOCK (L) Manual override Press and turn for the locking type. (): Orange (): Green L (Rail mounting hole pitch.) L Power supply terminals (M terminal screws).9. DIN rail holding screw. R P (X, PE ports) pplicable tubing O.D.: ø... (When equipped with switch Triangle mark.9 PE X pplicable connector: 0 pins MIL type With strain relief (Conforming to MIL-C-0) R P pplicable connector: pins MIL type With strain relief (Conforming to MIL-C-0).. The indication marking is for VDC. Triangle mark position pplicable connector: 0 pins MIL type With strain relief (Conforming to MIL-C-0) SJ SY SV SYJ SZ VP S000 VQ VQ VQ VQC VQZ SQ VFS VFR VQ. Internal Pilot Manifold L Dimension L n L L L L ON. 9 ON. 9. Switch (When equipped with switch) (.) (DIN rail dimension). (.) Triangle mark position Triangle mark position 0PG (0 pins) 0PH (0 pins) Note ) Types 0PG and 0PH differ only in their connectors, and the L through L dimensions are the same as type 0P. Note ) For manifold dimensions with elbow fitting, refer to page. n: Stations External Pilot Manifold L Dimension L n L L L L n: Stations Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

20 Series SZ000 Dimensions with Elbow Fitting: SZ000 Plug-in, D-sub Connector L SSZ-0FD - Stations U - (The fitting dimension of the flat cable and non plug-in types is the same.). (Pitch) P=0. LOCK (.). 0. (.9).. (R) Port () port (P) port [ (P), (R) Port ] pplicable tubing O.D.: ø () port FREE [Valve]. (.) (). [Supply/Exhaust block]. () (P) () (R) (.). () (.) U side Downward (Type ). (Station n) (Station ) (.) (DIN rail dimension) Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

21 Port Solenoid Valve Non Plug-in Type Series SZ000 How to Order Non plug-in manifold SJ SSZ 0 0 U CE-compliant SY SV 0 0 Stations stations 0 stations SUP/EXH block mounting position D U M * ( to 0 stations) U side ( to 0 stations) oth sides ( to 0 stations) Special specifications * For special specifications, indicate separately by the manifold specification sheet. SUP/EXH block fitting specifications Straight L Elbow type (Upward) Elbow type (Downward) Pilot type Internal pilot R External pilot Q CE-compliant Option When a longer DIN rail is desired than the specified stations, specify the station number to be required. SYJ SZ VP S000 VQ VQ VQ VQC How to Order Valve Manifold ssembly Ordering example (SZ000, Non plug-in) VQZ SQ SUP/EXH block (U side mounting) Double solenoid ( VDC) SZ0-MZ-C (sets) Single solenoid ( VDC) SZ0-MZ-C (sets) VFS VFR VQ U side Stations SSZ-0-0U set (Manifold part number) * SZ0-MZ-C sets (Single solenoid part no.) * SZ0-MZ-C sets (Double solenoid part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Stations are counted from as the st one. Indicate the valves to be attached below the manifold part number, in order starting from station as shown in the drawing. When entry of part numbers becomes complicated, indicate on the manifold specification sheet. Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

22 Series SZ000 How to Order SZ 0 M C Type of actuation C position single solenoid () position double solenoid () () (E)(P)(E) () (E)(P)(E) position closed center () () (E)(P)(E) position exhaust center () () (E)(P)(E) position pressure center SOL.a () () (E)(P)(E) position dual port valve: N.C./N.C. () () SOL.b position dual port valve: N.O./N.O. SOL.a SOL.b position dual port valve: N.C./N.O. SOL.a (R) () (R) () (R) (P) (P) SOL.b (P) (R) () (R) () (R) Pilot type Internal pilot R External pilot The position dual port valve is not available with external pilot specifications. ack pressure check valve None K uilt-in The built-in back pressure check valve type has an effective area approximately 0% smaller. The position valve is not available with back pressure check valve. Rated VDC VDC V VDC S VDC R VDC Common specifications Positive common N Negative common The symbol is when not equipped with light/surge. Electrical entry Manual override : Non-locking push type D: Push-turn locking slotted type Without light/surge With surge S With light/surge Z M: With lead wire (Length 00 mm) MN: Without lead wire, port size C: for ø C: for ø M: M x 0. CE-compliant Q CE-compliant Made to Order Main Valve Fluoro X90 Rubber Specifications (Refe to page 9.) Elbow fitting assembly (Upward) L: ø elbow fitting assembly L: ø elbow fitting assembly Elbow fitting assembly (Downward) : ø elbow fitting assembly : ø elbow fitting assembly MO: Without connector COM COM Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

23 Cassette Type Manifold Series SZ000 Manifold Specifications Model Type SSZ-0 Made to Order Specifications (For details, refer to page 9.) Manifold (P: SUP), / (R: EXH) system Valve stations (), () port Porting specifications Port size Mass W (g) () Location Direction (P), /(R) port (), () port n: Number of SUP/EXH blocks m: Weight of DIN rail Flow Characteristics Port size,, (P, E, E) C, (, ) C C b Non plug-in type Common SUP, EXH to 0 stations Valve Lateral, Upward, Downward C C, C, M W = n + m + 9 Note ) In cases such as those where many valves are operated simultaneously, use type (double side SUP/EXH), applying pressure to the (P) ports on both sides and exhausting from the (R) ports on both sides. Note ) The mass W is the value for the D-sub connector manifold with power supply terminals only. To obtain the mass with solenoid valves attached, add the solenoid valve mass given on page for the appropriate number of stations. For DIN rail mass, refer to page. Flow characteristics Cv M Note) The value is for manifold base with stations and individually operated position type. Values inside [ ] are for position dual port valves. b Cv SJ SY SV SYJ SZ VP S000 VQ VQ VQ VQC VQZ SQ VFS VFR VQ Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

24 Series SZ000 Manifold Exploded View Type 0 (Non plug-in) manifold U side DIN rail holding screw q e t r w DIN rail holding screw Component Parts No. Description End block assembly End block assembly SUP block bush assembly SUP block bush assembly DIN rail Part no. SUP/EXH block assembly SZ SZ000-- SZ000-- SZ000-- SZ000-- VZ Note C: With for ø C: With for ø L: With for ø (Elbow fetching upward) L: With for ø (Elbow fetching upward) : With for ø (Elbow fetching downward) : With for ø (Elbow fetching downward) U side Refer to page. y Manifold Station Expansion Station expansion is possible at any position. () Loosen one DIN rail holding screw on either U side or. () Separate the blocks at the location where station expansion is desired. () Mount the valve on the DIN rail. () While pressing the manifold together from both sides, retighten the DIN rail holding screw of the end block assembly which was loosened. Caution (Tightening torque:. N m) Caution. e sure to shut off the power and air supplies before disassembly. Furthermore, since air may remain inside the actuator, piping and manifold, confirm that the air is completely exhausted before performing any work.. When disassembly and assembly are performed, air leakage may result if connections between blocks and tightening of the end block s holding screw, is inadequate. efore supplying air, confirm that there are no gaps, etc. between blocks, and that manifold blocks are securely fastened to the DIN rail. Then supply air and confirm that there is no air leakage before operating. 0 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

25 Cassette Type Manifold Series SZ000 Dimensions: SZ000 Non Plug-in SSZ-0- Stations U. (Pitch) P=0. [(), () port] pplicable tubing O.D.: ø ø. With external pilot. [(P), (R) port] pplicable tubing O.D.: ø R P... R P (X, PE ports) pplicable tubing O.D.: ø X PE SJ SY SV SYJ (.) U side L (L). SZ VP S000 VQ VQ VQ DIN rail COM COM COM COM COM Manual override Press and turn for the locking type. (): Orange (): Green L (Rail mounting hole pitch.) L DIN rail holding screw 00 Lead wire length. VQC VQZ SQ VFS VFR VQ (Station n) (Station ) side: Orange side: Green. (.) (DIN rail dimension) Note) For manifold dimensions with elbow fitting, refer to page. Internal Pilot Manifold L Dimension L n L L L L n: Stations External Pilot Manifold L Dimension L n L L L L n: Stations Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

26 Series SZ000 Dimensions: SZ000 Non Plug-in SSZ-0- Stations D (Pitch) P=0.. [(P), (R) port] pplicable tubing O.D.: ø With external pilot... P R P X R PE [(), () port] pplicable tubing O.D.: ø ø (.) (X, PE ports) pplicable tubing O.D.: ø U side L. (L) COM COM COM COM COM DIN rail Manual override Press and turn for the locking type. (): Orange (): Green L (Rail mounting hole pitch.) DIN rail holding screw 00 Lead wire length. L (Station n) (Station ) side: Orange side: Green. (.) (DIN rail dimension) Note) For manifold dimensions with elbow fitting, refer to page. Internal Pilot Manifold L Dimension L n L L L L n: Stations External Pilot Manifold L Dimension L n L L L L n: Stations Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

27 Cassette Type Manifold Series SZ000 Dimensions: SZ000 Non Plug-in SSZ-0- Stations. (Pitch) P=0. [(P), (R) port] pplicable tubing O.D.: ø With external pilot... R R. R PE R SJ P [(), () port] pplicable tubing O.D.: ø ø (.).. U side L P. (L)... P (X, PE ports) pplicable tubing O.D.: ø X P SY SV SYJ SZ VP S000 VQ VQ VQ DIN rail COM COM COM COM COM Manual override Press and turn for the locking type. : Orange : Green L (Rail mounting hole pitch.) L DIN rail holding screw 00 Lead wire length. VQC VQZ SQ VFS VFR (Station n) (Station ) VQ side: Orange side: Green. (.) (DIN rail dimension) Note) For manifold dimensions with elbow fitting, refer to page. Internal Pilot Manifold L Dimension L n L L L L n: Stations External Pilot Manifold L Dimension L n L L L L n: Stations Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

28 Type0S Port Solenoid Valve EX0 Integrated Type (for Output) Serial Transmission System Series SZ000 How to Order Manifold SI unit specifications Symbol Protocol type 0 Without SI unit F NKE Corp.: Uni-wire System ( output points) SSZ 0S Q SI unit mounting position D D This should be indicated even without SI unit. 0 NKE Corp.: H Valve stations Uni-wire H System Symbol Stations Note SUNX Corp.: J 0 stations S-LINK ( output points) J SUNX Corp.: Double wiring specification S-LINK ( output points) 0 stations Q Device Net 0 stations Specified layout OMRON Corp.: R Compous/S System ( output points) (Up to solenoids possible.) stations OMRON Corp.: R Note ) Double wiring specifications: Compous/S System ( output points) Single, double, position and V CC-LINK position solenoid valves can be used at all of the manifold stations. Note ) Specified layout: Indicate wiring specifications on the manifold specification sheet. (Note that double, and position valves cannot be used where single solenoid wiring has been specified.) Note ) R and J are available with up to solenoids. SI unit part no. Symbol Protocol type SI unit part no. CE-compliant F NKE Corp.: Uni-wire System EX0-SUW H NKE Corp.: Uni-wire H System EX0-SUH J SUNX Corp.: S-LINK ( output points) EX0-SSL J SUNX Corp.: S-LINK ( output points) EX0-SSL Q Device Net EX0-SDN R OMRON Corp.: Compous/S ( output points) EX0-SCS R OMRON Corp.: Compous/S ( output points) EX0-SCS V CC-LINK EX0-SMJ U SUP/EXH block mounting position U U side ( to 0 stations) D ( to 0 stations) oth sides ( to stations) M Special specifications For special specifications, indicate separately by the manifold specification sheet. Note) total of up to SUP/EXH blocks can be mounted. Please contact SMC if or more will be mounted. CE-compliant Q CE-compliant Option When a longer DIN rail is desired than the specified stations, specify the station number to be required. SUP/EXH block fitting specifications Straight L Elbow type (Upward) Elbow type (Downward) Pilot type Internal pilot R External pilot How to Order Valve Manifold ssembly Ordering example (Compo us/s compatible SI unit) SUP/EXH block assembly (U side mounting) Double solenoid ( VDC) SZ0-LOZ-C ( sets) Single solenoid ( VDC) SZ0-LOZ-C ( sets) SSZ-0SRD-0U SZ0-LOZ-C SZ0-LOZ-C set (manifold part number) sets (Single solenoid part no.) sets (Double solenoid part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. U side Stations Stations are counted from as the st one. Indicate the valves to be attached below the manifold part number, in order starting from station as shown in the drawing. When entry of part numbers becomes complicated, indicate on the manifold specification sheet. SI unit ( mounting) Refer to pages and for the details of EX0 integrated type (for output) serial transmission system. Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C Main Office: (0) -900-Outside Local rea: (00)

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),

More information

Series SV1000/2000/3000/4000

Series SV1000/2000/3000/4000 Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double

More information

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Series VQ Rubber Seal Space-saving profile Clean space saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1 Port Solenoid Valve Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Non plug-in manifold 0 0 S 60 Stations stations 0 stations SUP/EXH

More information

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000 D-sub Connector J Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000//000 Number of connectors: pins MIL-C-08 Conforming to JIS-X-0 --6 For details

More information

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection Rubber Seal Port Solenoid Valve Series SJ000/000 Cassette Type Manifold 0 mm 7. mm (SJ000) 0 mm (SJ000) Non plug-in type Individual wiring manifold SJ000 SJ000 Can be mounted together. Connecter connection

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type1P Type2P 5 Port Solenoid Valve ase Mounted Manifold ar Stock Type/Flat Ribbon Cable Series /5000/000 How to Order Manifold Type 1P/Compact style SS5Y 5 1P 05 C8 Manifold series 3 5, port size Thread

More information

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position

More information

Series SY3000/5000 How to Order Manifold

Series SY3000/5000 How to Order Manifold Type N ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN Rail Mounted/Connector ox SY/ How to Order Manifold SSY SY SY Specifications Symbol Specifications With connector box (COM spec.) N With

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Rubber Seal Series VQ Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

Example. U side. Stations SY5000

Example. U side. Stations SY5000 45 Type 5 ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN ail Mounted/Individual Wiring Series SY3000/5000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 3 45 05 U C6 Example

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type20P 5 Port Solenoid Valve ody Ported Manifold ar Stock Type/Flat Ribbon Cable Series SY3000/5000/7000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 5 20P 05 Manifold series 3 SY3000

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Port Solenoid Valve Metal Seal Rubber Seal Series Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000

More information

VQ1000. How to Order Manifold. Kit type

VQ1000. How to Order Manifold. Kit type - - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold

More information

CAT.E152-5 Port Solenoid Valve/Body Ported Cassette Type Manifold. Series SZ3000

CAT.E152-5 Port Solenoid Valve/Body Ported Cassette Type Manifold. Series SZ3000 CAT.E- Port Solenoid Valve/Body Ported Cassette Type Manifold Series SZ000 The plug-in cassette system makes valve replacement easy. A plug-in manifold has been realized having a manifold height of.mm

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal Port Solenoid Valve Cassette Type Manifold Rubber Seal 7.mm (SJ000) SJ000 SJ000 Can be mounted together. 0mm (SJ000) Connector connection New New cable type manifold is added! New Additional options are

More information

Series VQZ1000/2000/3000 Single Unit

Series VQZ1000/2000/3000 Single Unit +- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body

More information

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring Type4 SY000/000 ase Mounted Monifold Stacking Type/DIN ail Mounted Individual Wiring How to Order Manifold SSY 4 0 U C6 How to Order Valve Manifold ssembly Ordering example SY000 SY000 Valve stations 02

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Vacuum Release Valve with Restrictor Series SJ3A6 SJ Plug-in Type Connector Connection P.86 D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Non Plug-in Type Individual

More information

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry

More information

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted

More information

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308 Cable ppendix Cable ppendix Multi-way cables The multi-pole connector cables used on SMC valves are common across several ranges. Cables are available in accordance with the MIL standard C-08 and also

More information

How to Order Manifold. Kit type L8 B4 B6 B8 LM

How to Order Manifold. Kit type L8 B4 B6 B8 LM 0 Stations station VVQ Series VQ000 The maximum and minimum number of are varied depending on. (Refer to the table below.) Series VQ000 ase Mounted Plug-in Unit Manifold Plug-in unit 08 C Cylinder port

More information

Fieldbus System (Output device for driving 5 port solenoid valves)

Fieldbus System (Output device for driving 5 port solenoid valves) Fieldbus System (Output device for driving port solenoid valves) New Compact 8mm (ctual size) Space-saving Installation IP67 RoHS EtherNet/IP added! For units with D-sub connector, and when connected to

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications Series -SQ00 Port Solenoid Valve Plug-in Unit [Option] How to Order Manifold Electrical entry F kit D-sub connector kit P kit SSQ 08 FD Kit type Flat ribbon cable connector kit J kit Flat ribbon cable

More information

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A Type N SY/ ase ounted anifold Stacking Type/DIN Rail ounted Connector ox How to Order anifold SSY SY SY Specifications Symbol Specifications With connector box (CO spec.) N With connector box ( CO spec.)

More information

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating / ort Solenoid Valve ubber Seal Series SYJ000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Specifications JIS Symbol port port (manifold) position

More information

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve CT.E- ase Mounted Type Series VQ Port Metal Seal/Rubber Seal Solenoid Valve dvanced manifold va the new age of factory au ase Mounted Type Space saving profile Clean space saving design with all pilot

More information

New Concept Connector Type Manifold

New Concept Connector Type Manifold New Concept Connector Type Manifold Series /000/3000/000 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration.

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve ubber Seal / ort Solenoid Valve Series 000 / 000 / 000 [Option] SJ SY SV SZ V S000 VQ VQ VQ VQC VQZ SQ VFS VF VQ Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread

More information

Plug Lead Unit: Flip Type

Plug Lead Unit: Flip Type Series ody orted lug Lead Unit: Flip Type For details about certified products conforming to international standards, visit us at www.smcworld.com. 0 Series Kit/Electrical entry/cable length F kit (D-sub

More information

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer Base Mounted Metal Seal/Rubber Seal VQ Built-in silencer, direct exhaust Space-saving profile All pilot valves are compactly mounted on one side. The space-saving design of mounting all fittings on one

More information

Series PCW. PC Wiring System

Series PCW. PC Wiring System CT.ES0-0 PC Wiring System Series PCW The PC wiring system is a revolutionary new system that simplifies wiring between a PLC and all types of connected equipment. revolutionary new wiring system... 4VDC

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold Port Solenoid Valve VV00 Series Highly Integrated Unit Manifold po ted - pera irect-o d station es on rt valv ally ividu Ind wired n be ve ca val d. adde ector Con-inn connection) lug (For p ø connection

More information

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000) 5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M. V3 Cover

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR2 JIS Symbol type

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

5 Port Air Operated Valve

5 Port Air Operated Valve Port ir Operated Valve Series VF000/000/000 RoHS 22- Series VF000/000/000 Model Selection by Operating Conditions q ir Operated Valve: Single Unit Series Sonic conductance C[dm /(s bar)] Type of actuation

More information

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing

More information

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series VZS Series Variations Plug-in Type Base Mounted Type (With sub-plate) Non Plug-in Type Base Mounted Type (With sub-plate) Series Sonic conductance

More information

Base Mounted Plug-in/Plug Lead: Single Unit

Base Mounted Plug-in/Plug Lead: Single Unit ase mounted VQ ase Mounted lug-in/lug Lead: Single Unit Model Number of solenoids Model Single Metal seal VQ Rubber seal VQ ouble Metal seal VQ Rubber seal VQ Closed Metal seal VQ VQ center Rubber seal

More information

Single Valve/Sub-plate Type IP67 Compliant 90-SV Series

Single Valve/Sub-plate Type IP67 Compliant 90-SV Series Single Valve/Sub-plate Type IP7 Compliant -SV Series SV 00 W U aterial restriction Series -SV000 -SV000 Thread type c F G N NPT T NPTF A B SOL.a SOL.a Type of actuation position single (EA) (P)(EB) position

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot ubber seal ort ilot Solenoid Valve Series SYJ00 Specifications efer to www.smcworld.com for details of products compatible with overseas standards. Body ported Base mounted Fluid Operating pressure range

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

3 Port Air Operated Valve

3 Port Air Operated Valve Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation

More information

0.35 W (Without light)

0.35 W (Without light) Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:

More information

Fieldbus System (Gateway Decentralized Type)

Fieldbus System (Gateway Decentralized Type) Fieldbus System (Gateway Decentralized Type) * * Except the SY, VQC and S0700 valves GW Unit which supports PROFINET added. New M connector type Input Unit added. Decentralized valve installation Valves

More information

Rubber Seal VP300/500/700

Rubber Seal VP300/500/700 Port Pilot Operated Poppet Rubber Seal 00/500/700 High flow capacity Cv1.0 (00), Cv. (500), Cv.0 (700) Low power consumption: 1.8W(DC) Possible to use as either selector valve or divider valve Changeable

More information

How to Order Manifold. Option Symbol

How to Order Manifold. Option Symbol Series Plug Lead nit For details about certified products conforming to international standards, visit us at www.smcworld.com. Series/Manifold 12 Stations 01 1 station Kit/Electrical entry/cable length

More information

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot 3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in

More information

Gateway System Serial Transmission System

Gateway System Serial Transmission System Gateway System Series 00 I compliant V S000 C Tie-rod base Z pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000/000/000 Number of output points: points Connected to the 00GW

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

5 Port Solenoid Valve Plug Lead Type

5 Port Solenoid Valve Plug Lead Type 5 Port Solenoid alve Plug Lead Type Series Body Ported Flow rate characteristics For single/double solenoid C [dm 3 /(s bar)]: 0.6 Single Unit alve width: 7.4 mm Possible to drive cylinders: Up to ø32

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve CT.ES8 / ort Solenoid Valve Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M.7 to M2. 앬 Flow Characteristics Series Cover (stainless

More information

Vacuum System Peripherals

Vacuum System Peripherals Vacuum System Peripherals Vacuum Regulator/Electronic Vacuum Regulator Vacuum regulator: IRV0/0 Electronic vacuum regulator: ITV009/ITV09 Directional Control Valve Selection guide of directional control

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position

More information

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC)

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC) Port Solenoid Valve/Direct Poppet Rubber seal Series VK3000 Nl/min 147 Compact/Width 18 X Length 8 (mm) Low power consumption 4W DC (Standard) 2W DC (Energy saver) Standard copper free specification All

More information

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is. Port Solenoid Valve Series VQ 00 Unprecedented high speed, stable response, and extra-long service life. ON:.ms, OFF: ms, Dispension accuracy ±ms (With indicator light and surge voltage suppressor; supply

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model 2 position 3 position

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

Series SYJ300/500/700

Series SYJ300/500/700 ort Solenoid Valve ubber Seal Series SYJ00/00/00 Low power consumption: 0.W (Without light) (Current draw: 1m at 4V DC) Completely interchangeable ilot exhaust with the previous series VJ00/00/00 and VZ00/00.

More information

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Body Ported Base Mounted Series S000 S000 S000 S000 S000 S4000 S5000 Sonic conductance C [dm /s bar)] 4/ 5/(A/B R/R) Single Double.8.4

More information

How to Order Manifold. Control unit Refer to pages to Kit/Electrical entry/cable length. kit (D-sub connector) U0 U1 U2

How to Order Manifold. Control unit Refer to pages to Kit/Electrical entry/cable length. kit (D-sub connector) U0 U1 U2 VQ000 ase Mounted Plug-in nit For details aout certified products conforming to international standards, visit us at www.smcworld.com. Type of connection VVQ VQ000 R port P port Port R Manifold Plug-in

More information

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I ISO Standard Solenoid Valve Series VQ7-6/7-8 (Size ) (Size ) Conforms to ISO Standard /I.0- Ideal for driving cylinders up to Large flow capacity ø00 (VQ7-6, Size ) ø60 (VQ7-8, Size ) Nl/min VQ7-6: 668.

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 044 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000 racket

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry TEX Compliant Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 44 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000

More information

Applicable bore size. CC-Link. EtherNet/IP. Decentralized Serial Wiring. EtherCAT I/O. Serial unit: EX600 IP67 compliant. Serial unit: EX500

Applicable bore size. CC-Link. EtherNet/IP. Decentralized Serial Wiring. EtherCAT I/O. Serial unit: EX600 IP67 compliant. Serial unit: EX500 5 Port Solenoid Valve Series C000 Metal Seal Rubber Seal Compact and large flow Type (Series) Manifold pitch (mm) C000 5 6. 0.7.7 7. 0..0 to ø Note) Flow characteristics: position single, / 5/ (/ R/R)

More information

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A) ort Solenoid Valve ubber Seal Series SY00 Low power consumption: 0.W (Standard, Without light) (Current draw: m at V DC) Large flow capacity style:0.7w (Current draw: m at V DC) Body width: 0mm 7.8 Nl/min

More information

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit CT.EUS8 UK ower Consumption / ort Solenoid Valve With ower Saving Circuit Series SYJ000/000/7000 Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced

More information

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type. Series -S00 ompact Direct Operated Port Solenoid Valve ontrol Valves ase mounted ody ported lean Series lean Series V S R oil voltage 24 VD VD VD VD VD Power consumption Pressure specification Flow rate

More information