Fieldbus System (Output device for driving 5 port solenoid valves)

Size: px
Start display at page:

Download "Fieldbus System (Output device for driving 5 port solenoid valves)"

Transcription

1 Fieldbus System (Output device for driving port solenoid valves) New Compact 8mm (ctual size) Space-saving Installation IP67 RoHS EtherNet/IP added! For units with D-sub connector, and when connected to S0700 manifolds, it is IP0. Drives up to solenoids Daisy-chain wiring communication pplicable Fieldbus protocols New Top ported valve ottom ported valve Side ported valve Mixed valve sizes manifold 7 mm width valve Series EX60 IP67 IP67 IP67 IP0 CT.E0-

2 Manifold length is shortened by the small fieldbus output module (SI unit). 8. mm 8 mm Wiring and piping from the same direction is possible. (for side ported) Effective for installation in locations where space is limited above the valve. Existing model EX0 External branch connector is not necessary. Daisy-chain wiring is possible. Reduced wiring space EX60 ranch connector Existing model (EX0) External terminating resistor is not necessary. (Only available for PROFIUS DP, CC-Link communication connectors) ON/OFF switching is possible with an internal terminating resistor. External terminating resistor is not necessary. External terminating resistor Product Specification Variations Number of outputs Output polarity PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN US OUT US IN P P / E / E Communication connector D-sub Internal terminating resistor US OUT Communication connector examples P P US IN / E / E SI unit Features Fieldbus communication connector (PROFIUS DP) D-sub communication connector (PROFIUS DP)

3 Series SY000/000 Pressure switch Valve piping direction variations!piping is possible from directions. Top ported <Example of Use> ottom ported Side ported y mounting top ported valves on side ported and bottom ported type manifolds, it is possible to detect the output of the / port with a pressure switch. Side ported Mixed mounting of top ported and side ported is possible. Valves can be freely connected up to stations. Mixed valve sizes manifold!it is possible to connect only the number of valves required, from to stations, to suit the application. (Maximum number of solenoids connected: ) Series S0700!Valves of different sizes, SY000 and SY000, can be mounted on the same manifold.!it is possible to connect only the number of 7 mm width valves required, from to stations. (Maximum number of solenoids connected: ) 7 mm width valves can be connected. %pplicable Valve Series Flow-rate characteristics (/m/) Maximum number of C [dm/(s bar)] b solenoids Series SY000.6 Power consumption (W) Enclosure 0. (standard) 0. (with powersaving circuit) IP67 page 7 0. IP0 page IP SY S SV SV Standards Page page SV VQC VQC VQC (standard) IP67 page 9.0 (standard) Note) For units with D-sub communication connector, it is IP0. Features

4 Fieldbus System Variations IP67/6 specification models I/O separated type I/O integrated type Valve outputs only Inputs only Gateway-type valve outputs only inputs only Valve outputs with multiple I/O s Valve outputs with inputs Number of valve outputs EX60 EX6 EX EX00 EX600 EX0 Number of inputs Number of valve outputs Number of inputs SI unit series EX60 None EX6 EX (total 6) (total 6) EX60 EX00 EX600 EX0 PROFINET EtherCT Open network EtherNet/IP PROFIUS DP DeviceNet CC-Link S-Interface CNopen CompoNet SY (Plug-in connector connecting base) S0700 (Stacking base) 0700 pplicable valve series SV VQC VQ Features

5 Fieldbus System Variations IP0 specification models I/O separated type I/O integrated type Valve outputs only Inputs only Gateway-type valve outputs only inputs only Valve outputs with multiple I/O s Valve outputs with inputs Number of valve outputs EX0 EX EX EX0 EX80 EX0 Number of inputs Number of valve outputs Number of inputs SI unit series EX0 (total 6) None (total 6) EX EX EX0 EX80 EX0 pplicable valve series Open network PROFINET EtherCT EtherNet/IP PROFIUS DP DeviceNet CC-Link S-Interface CNopen CompoNet SY (Plug-in connector connecting base) SJ SY (Plug-in metal base) S0700 (ar stock) SY (ar stock) SY (Stacking base) SV VQ SQ SZ VQZ SYJ Features

6 SI Unit Integrated-type/For Output Series EX60 Compact design Note) RoHS Compact design for space saving Number of outputs Each / digital output type available in the series Output polarity Each negative common (PNP) / positive common (NPN) type available in the series Enclosure IP67 (For units with D-sub connector, and when connected with S0700 manifolds, it is IP0.) ON/OFF switching is possible with an internal terminating resistor for communication. Internal terminating resistor (Only for units compatible with PROFIUS DP, CC-Link communication connectors) SY000/000 VQC000/000/000 S0700 SV000/000/000 D D D D Note) The SY000/000, VQC000/000/000, and S0700 are not yet UL-compatible. How to Order SI Units EX60 S PR Communication protocol Symbol Protocol DN DN DeviceNet DN DN PR PR PR PR PROFIUS DP PR PR6 PR7 PR8 MJ MJ CC-Link MJ MJ EC EC EtherCT EC EC PN PN PROFINET PN PN EN EN EtherNet/IP EN EN Number of outputs Communication connector SI unit output polarity Source/PNP (Negative common) Sink/NPN (Positive common) Source/PNP (Negative common) Sink/NPN (Positive common) Source/PNP (Negative common) Sink/NPN (Positive common) Source/PNP (Negative common) Sink/NPN (Positive common) Source/PNP (Negative common) Sink/NPN (Positive common) D-sub Note) Source/PNP (Negative common) Sink/NPN (Positive common) Source/PNP (Negative common) Sink/NPN (Positive common) Source/PNP (Negative common) Sink/NPN (Positive common) Source/PNP (Negative common) Sink/NPN (Positive common) Source/PNP (Negative common) Sink/NPN (Positive common) Source/PNP (Negative common) Sink/NPN (Positive common) Source/PNP (Negative common) Sink/NPN (Positive common) Source/PNP (Negative common) Sink/NPN (Positive common) Source/PNP (Negative common) Sink/NPN (Positive common) Note) Enclosure is IP0 when the communication connector is D-sub. Manifold symbol QN Q QN Q NN N NN N NCN NC NDN ND VN V VN V DN D DN D FN F FN F EN E EN E

7 Integrated-type/For Output Series EX60 SI Unit Specifications pplicable system Model Protocol I/O occupation area (Inputs/Outputs) Communication speed Power supply for control Power supply for output Power supply for communication Version Note ) Configuration file Note ) Power supply voltage Internal current consumption Power supply voltage Power supply voltage Internal current consumption Communication connector specification Terminating resistor switch EX60-SPR/ EX60-SPR/ EX60-SPR/7 EX60-SPR6/8 EX60-SDN/ EX60-SDN/ EX60-SMJ/ EX60-SMJ/ PROFIUS DP DeviceNet CC-Link DP-V0 Volume (Edition.) Volume (Edition.) Ver..0 GSD file EDS file SMJ: / SMJ: / SMJ: / SMJ: / SPR: 0/ SPR: 0/ uilt-in Source/PNP (Negative common) SPR: 0/ SPR: 0/ Sink/NPN (Positive common) Output type SPR: points SPR: points Number of outputs SPR: points SPR: points Output Load Supplied voltage SPR: Max..0 Supplied current SPR: Max..0 Enclosure Operating temperature range Environmental Operating humidity range resistance Withstand voltage Insulation resistance Standards Weight Mounting screw ccessories Seal cap (for connector socket) SPR: 0/ SPR6: 0/ SDN: 0/ SDN: 0/ SPR7: 0/ SPR8: 0/ SDN: 0/ SDN: 0/ ( station, remote I/O stations) ( station, remote I/O stations) k/0 k/00 kbps 6 k/6 k/. M/ M/0 Mbps.6 to 6. VDC 00 m or less.8 to 6. VDC to VDC 00 m or less D-sub None uilt-in 9.6 k/9. k/. k/9.7 k/ 87. k/00 k/. M/ M/6 M/ Mbps.6 to 6. VDC 00 m or less Source/PNP (Negative common) Sink/NPN (Positive common) Source/PNP (Negative common) Sink/NPN (Positive common) Source/PNP (Negative common) SPR: points SPR6: points SDN: points SDN: points SMJ: points SPR7: points SPR8: points SDN: points SDN: points SMJ: points Solenoid valve with protective circuit for surge voltage of VDC/. W or less (SMC) VDC SPR: Max..0 SPR: Max..0 SPR6: Max..0 SDN: Max..0 SDN: Max..0 SMJ: Max..0 SPR: Max..0 SPR7: Max..0 SPR8: Max..0 SDN: Max..0 SDN: Max..0 SMJ: Max..0 IP67 IP0 IP67 0 to 0C to 8%RH (No condensation) 00 VC for minute between terminals and housing 0 M or more (00 VDC measured via megohmmeter) between terminals and housing CE marking, UL (CS) compatible 00 g pcs. EX9-WTS ( pc.) EX9-WTS ( pc.) Sink/NPN (Positive common) SMJ: points SMJ: points SMJ: Max..0 SMJ: Max..0 EX60 SY SV pplicable system Model Protocol I/O occupation area (Inputs/Outputs) Communication speed Power supply for control Power supply for output Power supply for communication Internal current consumption Communication connector specification Terminating resistor switch Output Version Note ) Configuration file Note ) Power supply voltage Internal current consumption Power supply voltage Power supply voltage Output type Source/PNP Sink/NPN Source/PNP Sink/NPN Source/PNP Sink/NPN (Negative common) (Positive common) (Negative common) (Positive common) (Negative common) (Positive common) Number of outputs SEC: points SEC: points SPN: points SPN: points SEN: points SEN: points SEC: points SEC: points SPN: points SPN: points SEN: points SEN: points Load Solenoid valve with protective circuit for surge Solenoid valve with protective circuit for surge Solenoid valve with protective circuit for surge voltage of VDC/. W or less (SMC) voltage of VDC/.0 W or less (SMC) voltage of VDC/. W or less (SMC) Supplied voltage VDC Supplied voltage SEC: Max..0 SEC: Max..0 SPN: Max..0 SPN: Max..0 SEN: Max..0 SEN: Max..0 SEC: Max..0 SEC: Max..0 SEN: Max..0 SEN: Max..0 Enclosure Operating temperature range Environmental Operating humidity range resistance Withstand voltage Insulation resistance Standards Weight Mounting screw ccessories Seal cap (for connector socket) EX60-SEC/ EX60-SEC/ EX60-SPN/ EX60-SPN/ EX60-SEN/ EX60-SEN/ EtherCT Note ) PROFINET Note ) EtherNet/IP Note ) Conformance PROFINET Specification Volume (Edition.8) Test Record V.. Version. Volume (Edition.9) XML file GSD file EDS file SEC: 0/ SEC: 0/ SPN: 0/ SPN: 0/ SEN: / SEN: / SEC: 0/ SEC: 0/ SPN: 0/ SPN: 0/ SEN: / SEN: / 00 Mbps Note ) 0 M/00 Mbps Note ).6 to 6. VDC 00 m or less.8 to 6. VDC None SPN: Max..0 SPN: Max..0 IP67 0 to 0C to 8%RH (No condensation) 00 VC for minute between terminals and housing 0 M or more (00 VDC measured via megohmmeter) between terminals and housing CE marking, UL (CS) compatible 00 g pcs. EX9-WTS ( pc.) Note ) Please note that the version is subject to change. Note ) Use a CT or higher transmission cable for EtherCT, PROFINET, EtherNet/IP. Note ) Each file can be downloaded from the SMC website, VQC S0700

8 Series EX60 SI Unit Dimensions communication connector type D-sub communication connector type Functions of SI Unit Parts <LED indication and setting switch> <Setting switch> ddress switch Communication speed switch Terminating resistor switch Others Note) The setting switch varies depending on the model. Refer to the operation manual for details. Please download it via the SMC website, <LED indication> Communication state Unit power supply state Valve power supply state <Connector> communication connector type Part no. Communication protocol Communication connector () US OUT Communication connector () US IN Ground terminal Power connector () D-sub communication connector type EX60-SPR/-SPR -SPR/-SPR PROFIUS DP pins, socket, code pins, plug, code pins, plug, code Part no. Communication protocol Ground terminal Communication connector (D-sub) US IN/OUT Power connector () EX60-SDN DeviceNet pins, socket, code pins, socket, code pins, plug, code pins, plug, code M pins, plug, code EX60-SPR/-SPR6/-SPR7/-SPR8 PROFIUS DP M 9 pins, socket pins, plug, code EX60-SMJ CC-Link EX60-SEC EX60-SPN EX60-SEN EtherCT PROFINET EtherNet/IP pins, socket, D code pins, socket, D code pins pins, plug, code Note), pins Note), plug, code Note ) For EtherCT, PROFINET Note ) For EtherNet/IP

9 The man-hours can be decreased because no exclusive tools (such as solder, crimped terminal) are required. lso, the wire length can be adjusted at the site. QUICKON-ONE P. Piercecon P. Spring-cage Connection P. M8 The coloring and number indication to the electrical connection makes less wrong wiring. rown M8 White lue lack lue Just insert the connector and make / rotation. Knurl rown White lign here. Make / rotation. lack CT.ES00-7 Integrated-type/For Output Series EX60 ccessories q Communication cable with connector For SI units compatible with PROFIUS DP, DeviceNet, CC-Link For SI units compatible with EtherCT, PROFINET, EtherNet/IP Refer to the catalog (CT. ES00-7) for details. EX9 C 00 Cable length (L) M8/ Connector Conforming to IEC Fieldwireable Connectors [mm] Reduction in wiring time [mm] [mm] SPEEDCON Reduction in wiring time [mm] [mm] IP67 (IEC609) Conforming to IEC EN ø6.7 PSRJ 7. L Connector specification PSRJ plug (straight) RJ- connector RJ- EX60 Plug connector pin arrangement D code Terminal no. Terminal no. Connections (Straight cable) Core wire colors White Orange Pair White Pair 6 Green 7 8 Shield Plug connector pin arrangement SY For SI units compatible with EtherCT, PROFINET, EtherNet/IP PC 666 Cable length [mm] SV ø Plug connector pin arrangement SPEEDCON D code (ø6.) Terminal no. Wire guide color Yellow: TD+ White: RD+ Orange: TD lue: RD VQC Connections For SI units compatible with EtherCT, PROFINET, EtherNet/IP Fieldwireable connector PC 6 S ø7. Plug connector pin arrangement D code ø9 Width across flats Width across flats

10 Series EX60 ccessories w Power cable with connector (for SI units) For SI units compatible with PROFIUS DP, DeviceNet, EtherCT, PROFINET, EtherNet/IP EX00 P 00 Cable length (L) [mm] [mm] Straight connector type S Connector specification S Straight ngle ngle connector type ø.9 ø6 8. ø6 Socket connector pin arrangement code 8 8 Connections (PROFIUS DP/EtherCT) For SI units compatible with CC-Link Straight connector type EX9 C 00 L 0 0 code Core wire colors rown: VDC +0%/ % (Solenoid valve power supply) White: 0 V (Solenoid valve power supply) lue: VDC 0% (Control power supply) lack: 0 V (Control power supply) Gray: Not connected e Seal cap: For connector socket PC Cable length (L) [mm] [mm] [mm] Use this on ports that are not being used for communication connector ( connector socket). Use of this seal cap maintains the integrity of the IP67 enclosure. Note) Tighten the seal cap with the prescribed tightening torque. (For : 0. N m) EX9 SPEEDCON Cable length (L) [mm] [mm] [mm] Terminal no. PC 080 SPEEDCON 0807 Cable length (L) [mm] [mm] [mm] W TS Connector type TS For connector socket (0 pcs.) Socket connector pin arrangement Socket connector pin arrangement code Socket connector pin arrangement ø.8 ø.8 code Connections Socket connector pin arrangement SPEEDCON code Terminal no. Connections (DeviceNet, EtherNet/IP ) 8. SPEEDCON Terminal no. L 0... L 0. ø.00. ø.00. x For connector socket L L Core wire colors rown: Not connected Note ), VDC 0% (Control power supply) Note ) White: VDC +0%/ % (Solenoid valve power supply) lue: Not connected Note ), 0 V (Control power supply) Note ) lack: 0 V (Solenoid valve power supply) Gray: Not connected ø Cable core wire colors rown: VDC +0%/ % (Solenoid valve power supply) White: 0 V (Solenoid valve power supply) lue: VDC 0% (Control power supply) lack: 0 V (Control power supply) Gray: Not connected 0 Note ) For DeviceNet Note ) For EtherNet/IP

11 Manifold Solenoid Valves for Series EX60 Integrated-type (For Output) Serial Transmission System EX60 Series SY000/000 Page 7 SY Series SV000/000/000 Page SV Series VQC000/000/000 Page 9 VQC Series S0700 Page 8 S0700 6

12 Type 0 Side Ported Type ottom Ported Plug-in Connector Connecting ase: For EX60 Integrated-type (For Output) Serial Transmission System Series SY000/000 Refer to page for T y p e / o t t o m ported dimensions. q Series w Type 0 SSY SY000 SY000 Side ported ottom ported The SY000 manifold base is used for the bottom ported of the SY000. When ordering, refer to Plug-in Mixed Type Manifold (from page 7). e SI unit specifications Symbol 0 Q Q N N NC ND V V D D F F E EtherNet/IP r SI unit output polarity Positive common N Negative common i, port size (Metric) 0 S N N 0 U C6 q Protocol Number of outputs Communication connector Without SI unit DeviceNet PROFIUS DP D-sub Note) CC-Link EtherCT PROFINET E Note) IP0 for the D-sub applicable communication connector specification. For SI unit part number, refer to page. DIN rail and SI unit output polarity N cannot be selected for the product without SI unit. w t Valve stations In the case of the -output SI unit Symbol Stations Note 0 stations How to Order Manifold stations stations 8 stations stations stations e r t y u i o Double wiring Note ) Specified layout Note ) (vailable up to solenoids) stations In the case of the -output SI unit Symbol Stations Note 0 stations Double wiring Note ) Specified layout Note ) (vailable up to solenoids) Note ) Ensure a match with the common specifications of the valve to be used. Note ) Without SI unit, the symbol is nil. Symbol C C C C6 C8 CM L L6 L8 6 8 LM, port ø ø. ø ø6 ø8 Straight port, mixed sizes ø ø6 ø8 ø ø6 ø8 Elbow port, mixed sizes (Including upward and downward piping) SY000 SY000 SY000 P, E port size (s) ø8 ø0 ø0 Note) To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (Refer to the SY000/ 000 series catalog (CT. ES-0)). 7 Straight Upward Elbow Downward Type 0/ Side ported Note ) Double wiring: -position single, double, -position and -position valves can be used on all manifold stations. Use of a -position single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note ) Specified layout: Indicate the wiring specifications on the manifold specification sheet. (Note that -position double, -position and -position valves cannot be used where single wiring has been specified.) Note ) Includes the number of blanking plate assemblies. Note ) For the model without the SI unit (S0), note the maximum number of solenoids of the SI unit that will be mounted. If the layout is specified, indicate it on the manifold specification sheet. Type / ottom ported, port size (Inch) Symbol Elbow Downward, port y P, E port entry U U side ( to 0 stations) D D side ( to 0 stations) oth sides ( to stations) u SUP/EXH block assembly S R 0 Internal pilot Internal pilot, uilt-in silencer External pilot Direct mounting Without DIN rail (with bracket) For stations For stations SY000 N N N7 N9 CM LN LN7 LN9 N N7 N9 LM ø/8" ø/" ø/" ø/" Straight port, mixed sizes ø/" ø/" ø/" ø/" ø/" ø/" Elbow port, mixed sizes (Including upward and downward piping) P, E port size (s) ø/" Straight Upward /(E) port is plugged for the built-in silencer type. When the built-in silencer type is used, keep the exhaust port from coming in direct contact with water or other liquids. o Mounting and Option Symbol Mounting Option None Direct mounting Name plate (With station number) Name plate (Without station number) D Without name plate DIN rail Name plate (With station number) mounting Name plate (Without station number) Note ) Enter the number of stations inside. (Refer to DIN Rail Option below.) Note ) Only direct mounting is available for Type (ottom ported). DIN Rail Option Specify a longer rail than the total length of specified stations. SY000 SY000 ø/8" Type / ottom ported ø/8" RoHS When it is necessary to mount a DIN rail without an SI unit, select D0 and order DIN rail length separately, referring to L in the dimensions. Refer to the SY000/000 series catalog (CT. ES-0) for part numbers of DIN rail. Type 0/ Side ported Indicate the sizes on the manifold specification sheet in the case of CM, LM. The direction of P, E port fittings is the same as for, port. If selecting LM, indicate it on the manifold specification sheet for the P, E port fitting direction.

13 Plug-in Connector Connecting ase Series SY000/000 How to Order Manifold ssembly Example (SSY-0SNN-) -position single ( VDC) -position double ( VDC) SY00-U ( sets) SY00-U ( set) -position closed center ( VDC) SY00-U ( set) SSY-0SNN-0D-C6 set (Type 0 -station manifold base part no.) SY00-U sets (-position single part no.) SY00-U set (-position double part no.) SY00-U set (-position closed center part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the valve, etc. EX60 Manifold base ( stations) SSY-0SNN-0D-C6 U side D side Stations The valve arrangement is numbered as the st station from the D side. Under the manifold part number, state the valves to be mounted in order from the st station as shown in the figure above. If the arrangement becomes complicated, specify on a manifold specification sheet. Note) When mixing top ported configurations, select from page. Specify on a manifold specification sheet if plugs are required on the and port on the manifold. SY How to Order Valves (With two mounting screws) Refer to the SY000/000 series catalog (CT.ES-0) for details on valve specifications. q Series e Seal type 0 r Pilot type R t SY 0 0 SY000 SY000 Rubber seal Metal seal Internal pilot External pilot q w w Type of actuation -position single -position double -position closed center -position exhaust center -position pressure center -position dual -port valve (N.C./N.C.) -position dual -port valve (N.O./N.O.) C -position dual -port valve (N.C./N.O.) Only rubber seal type is available for the -position dual -port valve. ack pressure check valve (uilt-in valve type) H None uilt-in Only rubber seal type. Manifold installed type is available if the back pressure check valve is required for a valve with metal seal. Refer to the SY000/000 series catalog (CT.ES-0) for details. However, it is not recommended to use the built-in valve type and the manifold installed type at the same time because it will reduce the flow. The built-in valve type back pressure check valve is not available for the -position type. e r t y u i o!0! ase mounted K Pilot valve option Standard (0.7 MPa) Quick response type (0.7 MPa) High pressure type (.0 MPa) Only metal seal type is available for the high pressure type. Coil type Standard T With power saving circuit (Continuous duty type) e sure to select the power saving circuit type when a valve is continuously energized for long periods of time. Note the specified energizing time when power saving circuit is selected. Rated voltage VDC Light/surge voltage suppressor and common specification R U S Z NS NZ With surge voltage suppressor (Non-polar) With light/surge voltage suppressor (Non-polar) With surge voltage suppressor (Positive common) With light/surge voltage suppressor (Positive common) With surge voltage suppressor (Negative common) With light/surge voltage suppressor (Negative common) Only Z and NZ types are available for the product with power saving circuit. Select a valve from R, U, S or Z when the SI unit output polarity is (Positive common). Select a valve from R, U, NS or NZ when the SI unit output polarity is N (Negative common).!0 Manual override : Non-locking push type E: Push-turn locking manual type D: Push-turn locking slotted type F: Slide locking type! Type of mounting screw Round head combination screw Hexagon socket head cap screw Round head combination screw K (Falling-out-prevention type) Hexagon socket head cap screw H (Falling-out-prevention type) For K and H, the valve body cover has a drop prevention construction to stop the mounting screws from falling out when the valve is removed for maintenance etc. When ordering a valve individually, the base gasket is not included. Since the base gasket is attached to the manifold, please order the base gasket separately if it is needed for maintenance service. Refer to the SY000/000 series catalog (CT.ES-0) for part numbers of the base gasket and mounting screw. and H cannot be selected for the individual SUP/EXH spacer assembly or double check spacer assembly with residual pressure release valve. SV VQC S0700 Refer to the SMC website or the SY000/000 series catalog (CT.ES-0) for details on solenoid valve specifications, Common Precautions and Specific Product Precautions. Protective class class (Mark: ) 8

14 Series SY000/000 Dimensions: Type 0/For EX60/Series SY000 C U SSY-0S- Stations D(S, R) - C, N C, N C6, N7 (D) DIN rail holding screw (For DIN rail mounting) Silencer (exhaust port) (uilt-in silencer specification) DIN rail D side (L) L Light/surge voltage suppressor 8 U side Manual override Push-turn locking slotted type: ( Press, then rotate it. ) () port side : lue (For rubber seal) : Gray (For metal seal) () port side : Yellow (.8) SI unit. (.9) C6:.6 ( N7:7. ).7 L. L (DIN rail mounting hole pitch:.) L.7.6 x M mounting hole (Fitting for the type with P/E ports on U and/or D sides) [External pilot]. 7. [(P), /(E) port] pplicable tube O.D.: ø8, ø/" (Station ) (Station n) [(), () port] pplicable tube O.D.: ø : ø., ø/8" : ø, ø/" : ø6, ø/" PE P X (7.) (.8) US OUT US IN P P / E / E (Slide locking manual override) [PE: Pilot EXH port] [X: External pilot port] pplicable tube O.D.: ø, ø/" 6.. (Pitch) (7.8) P = (For DIN rail mounting) [Communication connector D-sub] US OUT US P P US IN / E / E Note) These figures show the SSY-0SQ-0D-C6. n: stations L L L L L

15 Plug-in Connector Connecting ase Series SY000/000 Dimensions: Type 0/For EX60/Series SY000 U C, N SSY-0S- Stations D(S, R) - C6, N7 ( D) C8, N9 DIN rail holding screw (For DIN rail mounting) Silencer (exhaust port) (uilt-in silencer specification) DIN rail D side (L) L Light/surge voltage suppressor U side 8 Manual override Push-turn locking slotted type: ( Press, then rotate it. ) () port side : lue (For rubber seal) : Gray (For metal seal) () port side : Yellow EX60 (.8) SY. (8.) (.9) SI unit (Fitting for the type with P/E ports on U and/or D sides) x M mounting hole.. L. L (DIN rail mounting hole pitch:.) L SV [External pilot] 0. (0) [(P), /(E) port] pplicable tube O.D.: ø0, ø/8" (Station ) (Station n) [(), () port] pplicable tube O.D.: ø, ø/" : ø6, ø/" : ø8, ø/" (9.8) (.7) US OUT / E X P PE [PE: Pilot EXH port] [X: External pilot port] pplicable tube O.D.: ø, ø/" US OUT US IN US / E P 8. 8 (Pitch) P = [Communication connector D-sub] P / E. 9. (0.) (Slide locking manual override) (For DIN rail mounting) VQC S US IN P P / E / E Note) These figures show the SSY-0SQ-0D-C8. n: Station L L L L L

16 Series SY000/000 Dimensions: Type /For EX60/Series SY000 U SSY-S- Stations D(S, R) - C, N C6, N7 C8, N9 D side Silencer (exhaust port) (uilt-in silencer specification) DIN rail L Light/surge voltage suppressor U side Manual override Push-turn locking slotted type: ( Press, then rotate it. ) () port side : lue (For rubber seal) : Gray (For metal seal) () port side : Yellow (.8) [Communication connector D-sub].. L. (Station ) (Station n) 0.9 x M mounting hole US (.9) 76.7 US OUT US IN (Fitting for the type with P/E ports on U and/or D sides) (9.) 78.9 (Slide locking manual override) 0. [External pilot] / (0) PE (Pitch) P = / E P / E (0.) P 9.7 E X (9.8) (.7) P [PE: Pilot EXH port] [X: External pilot port] pplicable tube O.D. C: ø(smc) N: ø/"(smc) [(P), /(E) port] pplicable tube O.D.: ø0, ø/8" Cut dimensions for panel mounting Refer to panel cut dimensions for details. [(), () port] pplicable tube O.D.: ø, ø/" : ø6, ø/" : ø8, ø/" Panel cut dimensions 7 US OUT US IN L x M hole x ø. Note) These figures show the SSY-SQ-0D-C8. n: Stations L L

17 S0700 VQC SV SY EX60

18 Type Top Ported Plug-in Connector Connecting ase: For EX60 Integrated-type (For Output) Serial Transmission System Series SY000/000 RoHS Refer to pages, for Type /Top ported dimensions. SSY S N N 0 U q How to Order Manifold w e r t y u i q Series N SY000 SY000 w SI unit specifications Symbol Protocol Number of outputs Communication connector 0 Without SI unit Q DeviceNet Q N N PROFIUS NC DP ND D-sub Note) V CC-Link V D EtherCT D F PROFINET F E EtherNet/IP E Note) IP0 for the D-sub applicable communication connector specification. For SI unit part number, refer to page. DIN rail and SI unit output polarity N cannot be selected for the product without SI unit. e SI unit output polarity Positive common Negative common Note ) Ensure a match with the common specifications of the valve to be used. Note ) Without SI unit, the symbol is nil. r Valve stations In the case of the -output SI unit Symbol Stations Note 0 stations 0 Note ) Double wiring: -position single, double, -position and -position valves can be used on all manifold stations. Use of a -position single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note ) Specified layout: Indicate the wiring specifications on the manifold specification sheet. (Note that -position double, -position and -position valves cannot be used where single wiring has been specified.) Note ) Includes the number of blanking plate assemblies. Note ) For the model without the SI unit (S0), note the maximum number of solenoids of the SI unit that will be mounted. If the layout is specified, indicate it on the manifold specification sheet. t P, E port entry U Note) D Note) stations stations stations Double wiring Note ) Specified layout Note ) (vailable up to solenoids) In the case of the -output SI unit Symbol Stations Note 0 stations stations stations stations Double wiring Note ) Specified layout Note ) (vailable up to solenoids) U side ( to 0 stations) D side ( to 0 stations) oth sides ( to stations) Note) y For type S, supply/exhaust block assembly with built-in silencer, choose U or D for P port entry. y SUP/EXH block assembly Internal pilot S Internal pilot, uilt-in silencer R External pilot For built-in silencer type, P and E ports are available on U and D sides. /(E) port is plugged. The silencer exhaust port is located on the opposite side of P, E port entry. (Example: When the P, E port entry is D side, the silencer exhaust port is U side.) When the built-in silencer type is used, keep the exhaust port from coming in direct contact with water or other liquids. u P, E port size (s) Symbol N i Mounting D D0 D D SY000 ø8 ø/" For N, sizes are in inches. Direct mounting DIN rail mounting (With DIN rail) DIN rail mounting (Without DIN rail) For stations For stations SY000 ø0 ø/8" Specify a longer rail than the standard length. When it is necessary to mount a DIN rail without an SI unit, select D0 and order DIN rail length separately, referring to L in the dimensions. Refer to the SY000/000 series catalog (CT.ES-0) for part numbers of DIN rail.

19 Plug-in Connector Connecting ase Series SY000/000 How to Order Manifold ssembly Example (SSY-SNN-) -position single ( VDC) SY0-U-C6 ( sets) -position double ( VDC) SY0-U-C6 ( set) -position closed center ( VDC) SY0-U-C6 ( set) SSY-SNN-0D set (Type -station manifold base part no.) SY0-U-C6 sets (-position single part no.) SY0-U-C6 set (-position double part no.) SY0-U-C6 set (-position closed center part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the valve, etc. EX60 Manifold base ( stations) SSY-SNN-0D q Series e Seal type 0 r Pilot type R H q w SY000 SY000 Rubber seal Metal seal Internal pilot External pilot None uilt-in D side w Type of actuation -position single -position double -position closed center -position exhaust center -position pressure center -position dual -port valve (N.C./N.C.) -position dual -port valve (N.O./N.O.) C -position dual -port valve (N.C./N.O.) Only rubber seal type is available for the -position dual -port valve. t ack pressure check valve (uilt-in valve type) Only rubber seal type. Manifold installed type is available if the back pressure check valve is required for a valve with metal seal. Refer to the SY000/000 series catalog (CT. ES-0) for details. However, it is not recommended to use the built-in valve type and the manifold installed type at the same time because it will reduce the flow. The built-in valve type back pressure check valve is not available for the -position type. U side Stations SY 0 C6 Refer to the SMC website or the SY000/000 series catalog (CT. ES-0) for details on solenoid valve s pecifications, Common Precautions and Specific Product Precautions. How to Order Valves (With two mounting screws) e r t y u i o!0!!! Top ported y Pilot valve option Standard (0.7 MPa) Quick response type (0.7 MPa) K High pressure type (.0 MPa) Only metal seal type is available for the high pressure type. u Coil type Standard T With power saving circuit (Continuous duty type) e sure to select the power saving circuit type when a valve is continuously energized for long periods of time. Note the specified energizing time when power saving circuit is selected. i Rated voltage VDC o Light/surge voltage suppressor and common specification R With surge voltage suppressor (Non-polar) U With light/surge voltage suppressor (Non-polar) S With surge voltage suppressor (Positive common) Z With light/surge voltage suppressor (Positive common) NS With surge voltage suppressor (Negative common) NZ With light/surge voltage suppressor (Negative common) Only Z and NZ types are available for the product with power saving circuit. Select a valve from R, U, S or Z when the SI unit output polarity is (Positive common). Select a valve from R, U, NS or NZ when the SI unit output polarity is N (Negative common).!0 Manual override : Non-locking push type E: Push-turn locking manual type The valve arrangement is numbered as the st station from the D side. Under the manifold part number, state the valves to be mounted in order from the st station as shown in the figure above. If the arrangement becomes complicated, specify on a manifold specification sheet. D: Push-turn locking slotted type F: Slide locking type!, port size Thread piping Symbol M 0 Symbol C C C C6 C8 Symbol N N N7 N9 Refer to the SY000/000 series catalog (CT.ES-0) for details on valve specifications. Port size M x 0.8 /8 (Metric) and port ø ø. ø ø6 ø8 (Inch) and port ø/8" ø/" ø/" ø/"! Thread type F N T Rc G NPT NPTF pplicable series SY000 SY000 SY000 SY000 SY000 SY000 Only is available for M.! Type of mounting screw Round head combination screw Hexagon socket head cap screw K Round head combination screw(falling-out-prevention type) H Hexagon socket head cap screw(falling-out-prevention type) For K and H, the valve body cover has a drop prevention construction to stop the mounting screws from falling out when the valve is removed for maintenance etc. When ordering a valve individually, the base gasket is not included. Since the base gasket is attached to the manifold, please order the base gasket separately if it is needed for maintenance service. Refer to the SY000/000 series catalog (CT.ES-0) for part numbers of the base gasket and mounting screw. and H cannot be selected for the individual SUP/EXH spacer assembly. Protective class class (Mark: ) S0700 VQC SV SY

20 Series SY000/000 Dimensions: Type /For EX60/Series SY000 U SSY-S- Stations D (S, R) (-D) DIN rail holding screw (For DIN rail mounting) D side [(P), /(E) port] pplicable tube O.D.: ø8, ø/" (L) 6 L Light/surge voltage suppressor (Pitch) P = 0. 8 U side Manual override Push-turn locking slotted type: ( ) Press, then rotate it. () port side : lue (For rubber seal) : Gray (For metal seal) () port side : Yellow Silencer (exhaust port) (uilt-in silencer specification) DIN rail PE X. /E (.8) P x M mounting hole.7.6 [External pilot] SI unit..7 L. L (DIN rail mounting hole pitch:.) L M x 0.8 [(), () port] [(), () port] pplicable tube O.D.: ø : ø., ø/8" : ø, ø/" : ø6, ø/" [PE: Pilot EXH port] [X: External pilot port] pplicable tube O.D.: ø, ø/" (Station ) (Station n) (.) (Fitting for the type with P/E ports on U and/or D sides) US OUT US IN PE /E P / 7. X P E (7.) (7.8) 6. US OUT P P US IN / E / E [Communication connector D-sub] US P / E (Slide locking manual override) (For DIN rail mounting) C6: 77. ( N7: 8. ) Note ) These figures show the SSY-SQ-0D. Note ) For built-in silencer type, a silencer is mounted on the opposite side of U or D side with P or E port. n:stations L L L L L

21 Plug-in Connector Connecting ase Series SY000/000 Dimensions: Type /For EX60/Series SY000 U SSY-S- Stations D (S, R) (-D) DIN rail holding screw (For DIN rail mounting) [(P), /(E) port] pplicable tube O.D.: ø0, ø/8" D side (L) L Light/surge voltage suppressor.. (Pitch) P = U side Manual override Push-turn locking slotted type: Press, then rotate it. () port side : lue (For rubber seal) : Gray (For metal seal) () port side : Yellow ( ) Silencer (exhaust port) (uilt-in silencer specification) 8 EX60 DIN rail PE. 6.7 (.8) / E X P. 0:. C: SY [External pilot]. SI unit L L (DIN rail mounting hole pitch:.) L. x M mounting hole /8 [(), () port] 0.9 [(), () port] pplicable tube O.D.: ø, ø/" : ø6, ø/" : ø8, ø/" SV. (Station ) (Station n) (7.) (Fitting for the type with P/E ports on U and/or D sides) PE US OUT US IN / E X P / E P [PE: Pilot EXH port] [X: External pilot port] pplicable tube O.D.: ø, ø/" (6.) (69.7) 8.7 US OUT P US IN / E US P / E [Communication connector D-sub] P / E (Slide locking manual override) (For DIN rail mounting) (9.) VQC S0700 Note ) These figures show the SSY-SQ-0D. Note ) For built-in silencer type, a silencer is mounted on the opposite side of U or D side with P or E port. n:stations L L L L L

22 Type 0 Side Ported Type ottom Ported SY000 can be mounted onto SY000 size manifold. Plug-in Connector Connecting ase: Plug-in Mixed Mounting Type Manifold For EX60 Integrated-type (For Output) Serial Transmission System Series SY000/000 How to Order Manifold RoHS Refer to page 0 for Type / ottom ported dimensions. Mixed Mounting Type It is possible to mount SY000 size valves on all stations. In this case, there is no need to fill in part i in the order code. However, the manifold block width should be. mm. q Type 0 Side ported ottom ported N w SI unit specifications Symbol 0 Q Q N N NC ND V V D D F F E E Protocol Number of outputs Communication connector Without SI unit DeviceNet PROFIUS DP D-sub Note) CC-Link EtherCT PROFINET EtherNet/IP Note) IP0 for the D-sub applicable communication connector specification. For SI unit part number, refer to page. DIN rail and SI unit output polarity N cannot be selected for the product without SI unit. How to Order Manifold ssembly Example (SSY-M0SNN-) -position double SY00-U( sets) SSY M 0 S N N 0 -position double SY00-U( sets) q e SI unit output polarity Manifold base ( stations) SSY-M0F-0D-C86 Positive common Negative common U w e r t Note ) Ensure a match with the common specifications of the valve to be used. Note ) Without SI unit, the symbol is nil. r Valve stations In the case of the -output SI unit Symbol Stations Note 0 stations 0 stations stations stations Double wiring Note ) Specified layout Note ) (vailable up to solenoids) t P, E port entry U U side ( to 0 stations) D D side ( to 0 stations) oth sides ( to stations) Refer to the page on the right for u,i,o C 8 6 y u i o!0 In the case of the -output SI unit Symbol Stations Note 0 stations Note ) Double wiring: -position single, double, -position and -position valves can be used on all manifold stations. Use of a -position single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note ) Specified layout: Indicate the wiring specifications on the manifold specification sheet. (Note that -position double, -position and -position valves cannot be used where single wiring has been specified.) Note ) Includes the number of blanking plate assemblies. Note ) For the model without the SI unit (S0), note the maximum number of solenoids of the SI unit that will be mounted. If the layout is specified, indicate it on the manifold specification sheet stations stations stations Double wiring Note ) Specified layout Note ) (vailable up to solenoids) y SUP/EXH block assembly Internal pilot S Internal pilot, uilt-in silencer R External pilot /(E) port is plugged for the built-in silencer type. When the built-in silencer type is used, keep the exhaust port from coming in direct contact with water or other liquids. D side Stations U side SSY-M0F-0D-C86 set (Type 0 -station manifold base part no.) SY00-U sets (-position double part no.) SY00-U sets (-position double part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the valve, etc. The valve arrangement is numbered as the st station from the D side. Under the manifold part number, state the valves to be mounted in order from the st station as shown in the figure above. If the arrangement becomes complicated, then indicate on the manifold specification sheet. Note ) When mounting top ported valves, select from page. In this case, use caution as there is also output on the and port on base side. Specify on a manifold specification sheet if plugs are required on the and port on base side. 7!0 Mounting and Option Mounting Symbol D Direct mounting DIN rail mounting Option None Name plate (With station number) Name plate (Without station number) Without name plate Name plate (With station number) Name plate (Without station number) Note ) Enter the number of stations inside. (Refer to DIN Rail Option below.) Note ) Only direct mounting is available for Type (ottom ported). DIN Rail Option 0 Standard length Without DIN rail (with bracket) For stations For stations Specify a longer rail than the total length of specified stations. [The SY000 valve is now at a mountable length (manifold block length of mm).] When it is necessary to mount a DIN rail without an SI unit, select D0 and calculate DIN rail length, referring to L in the dimensions on page 9.

23 Plug-in Connector Connecting ase Series SY000/000 u Fitting type Symbol, port C Metric size: Straight one-touch fitting L Metric size: Elbow one-touch fitting for upward Note) Metric size: Elbow one-touch fitting for downward Note) N Inch size: Straight one-touch fitting LN Inch size: Elbow one-touch fitting for upward Note) N Inch size: Elbow one-touch fitting for downward Note) CM Straight port, mixed sizes LM Elbow port, mixed sizes (Including upward and downward piping) Note) Note) To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly. Indicate the sizes on the manifold specification sheet in the case of CM, LM. The direction of P, E port fittings is the same as for, port. If selecting LM, indicate it on the manifold specification sheet for the P, E port fitting direction. Elbow fittings: ø, ø. and ø.8" are not available for the SY000 series. ø, ø., ø.8" and ø/" are not available for the SY000 series. q Series w Type of actuation C e Seal type 0 r Pilot type R How to Order Valves (With two mounting screws) SY000 SY000 Rubber seal Metal seal Internal pilot External pilot t ack pressure check valve (uilt-in valve type) H -position single -position double -position closed center -position exhaust center -position pressure center -position dual -port valve (N.C./N.C.) -position dual -port valve (N.O./N.O.) -position dual -port valve (N.C./N.O.) Only rubber seal type is available for the -position dual -port valve. None uilt-in q w Only rubber seal type. Manifold installed type is available if the back pressure check valve is required for a valve with metal seal. Refer to the SY000/000 series catalog (CT.ES-0) for details. However, it is not recommended to use the built-in valve type and the manifold installed type at the same time because it will reduce the flow. The built-in valve type back pressure check valve is not available for the -position type. SY 0 0 e r t y u i o!0! ase mounted y Pilot valve option Standard (0.7 MPa) Quick response type (0.7 MPa) K High pressure type (.0 MPa) Only metal seal type is available for the high pressure type. u Coil type T Standard With power saving circuit (Continuous duty type) e sure to select the power saving circuit type when a valve is continuously energized for long periods of time. Note the specified energizing time when power saving circuit is selected. i Rated voltage VDC o Light/surge voltage suppressor and common specification Without light/surge voltage suppressor (Non-polar) R With surge voltage suppressor (Non-polar) U With light/surge voltage suppressor (Non-polar) S With surge voltage suppressor (Positive common) Z With light/surge voltage suppressor (Positive common) NS With surge voltage suppressor (Negative common) NZ With light/surge voltage suppressor (Negative common) Only Z and NZ types are available for the product with power saving circuit. Select a valve from R, U, S or Z when the SI unit output polarity is (Positive common). Select a valve from R, U, NS or NZ when the SI unit output polarity is N (Negative common). i SY000:, port size (Metric) (Inch) Symbol 6 8 Port size ø ø6 ø8 For all stations of SY000 Symbol 7 9 Port size ø/" ø/" ø/" For all stations of SY000 No symbol needs to be specified when fitting type CM, LM is selected. o SY000:, port size (Metric) (Inch) Symbol 6 Refer to the SMC website or the SY000/000 series catalog (CT.ES-0) for details on solenoid valve specifications, Common Precautions and Specific Product Precautions. Port size ø ø. ø ø6 Symbol 7 Port size ø/8" ø/" ø/" No symbol needs to be specified when fitting type CM, LM is selected. Refer to the SY000/000 series catalog (CT.ES-0) for details on valve specifications.!0 Manual override : Non-locking push type E: Push-turn locking manual type D: Push-turn locking slotted type F: Slide locking type! Type of mounting screw Round head combination screw Hexagon socket head cap screw K Round head combination screw (Falling-out-prevention type) H Hexagon socket head cap screw (Falling-out-prevention type) For K and H, the valve body cover has a drop prevention construction to stop the mounting screws from falling out when the valve is removed for maintenance etc. When ordering a valve individually, the base gasket is not included. Since the base gasket is attached to the manifold, please order the base gasket separately if it is needed for maintenance service. Refer to the SY000/000 series catalog (CT.ES-0) for part numbers of the base gasket and mounting screw. and H cannot be selected for the individual SUP/EXH spacer assembly or double check spacer assembly with residual pressure release valve. 8 S0700 VQC SV SY EX60

24 Series SY000/000 Dimensions: Type 0/For EX60/Mixed Mounting Type SSY-M0S- Stations (-D) U D DIN rail D side (L) L DIN rail holding screw (For DIN rail mounting) Light/surge voltage suppressor U side 8 Manual override Push-turn locking slotted type: ( Press, then rotate it. ) () port side : lue (For rubber seal) : Gray (For metal seal) () port side : Yellow (.8) SI unit. (8.) (.9) (Fitting for the type with P/E ports on U and/or D sides). L L (DIN rail mounting hole pitch:.) L x M mounting hole. [(), () port] pplicable tube O.D.: ø, ø/" : ø6, ø/" : ø8, ø/" (Station ) (Station n) [(), () port] pplicable tube O.D.: ø : ø., ø/8" : ø, ø/" : ø6, ø/" US OUT US IN P / E P / E. (SY000). (SY000) 9. (SY000). (SY000) (Slide locking manual override) [(P), /(E) port] pplicable tube O.D.: ø0, ø/8" 8. 8 (Pitch of SY000) P = (0.) (Pitch of SY000) P = (For DIN rail mounting) Note ) These figures show the SSY-M0SQ-0D-C86. Note ) Refer to page 0 for dimensions of D-sub communication connector, external pilot and built-in silencer. EX60 Serial transmission Calculation of dimensions L =. x n + x n L =. x n + x n + 8 M = L/. + Remove all numbers after the decimal L =. x M + L = L 0. L = (L L)/ n: SY000 Valve stations n: SY000 Valve stations 9

25 Plug-in Connector Connecting ase Series SY000/000 Dimensions: Type /For EX60/Mixed Mounting Type SSY-MS- Stations U D SI unit D side L Light/surge voltage suppressor U side Manual override Push-turn locking slotted type: ( Press, then rotate it. ) () port side : lue (For rubber seal) : Gray (For metal seal) () port side : Yellow x M mounting hole EX60 (.8) 0... L SY (Station ) (Station n) 76.7 US OUT US IN (Slide locking manual override) SV (.9) (9.) (SY000) (Fitting for the type with P/E ports on U and/or D sides).7 (7.) (SY000) Panel cut dimensions L x M hole x ø / E 8 P [(P), /(E) port] pplicable tube O.D.: ø0, ø/8" (Pitch of SY000) P = (Pitch of SY000) P =. (0.) / E P [(), () port] pplicable tube O.D.: ø, ø/" : ø6, ø/" : ø8, ø/" 9.7 (SY000) 9.6 (SY000) (SY000) (SY000) Cut dimensions for panel mounting Refer to panel cut dimensions for details. [(), () port] pplicable tube O.D.: ø : ø., ø/8" : ø, ø/" : ø6, ø/" Note ) These figures show the SSY-MSQ-0D-C86. Note ) Refer to page for dimensions of D-sub communication connector, external pilot and built-in silencer. EX60 Serial transmission Calculation of dimensions L =. x n + x n L =. x n + x n + 8 VQC S0700 n: SY000 Valve stations n: SY000 Valve stations 0

Fieldbus System (Gateway Decentralized Type)

Fieldbus System (Gateway Decentralized Type) Fieldbus System (Gateway Decentralized Type) * * Except the SY, VQC and S0700 valves GW Unit which supports PROFINET added. New M connector type Input Unit added. Decentralized valve installation Valves

More information

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type20P 5 Port Solenoid Valve ody Ported Manifold ar Stock Type/Flat Ribbon Cable Series SY3000/5000/7000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 5 20P 05 Manifold series 3 SY3000

More information

Terminal Block Box (Spring Type) SY3000/5000/7000 Series

Terminal Block Box (Spring Type) SY3000/5000/7000 Series INFORMATION 5 ort olenoid alve Terminal lock ox (pring Type) Y3000/5000/7000 eries Compact RoH Height 6.7 mm shorter (Approx. 9% reduction) Installation area of the terminal block box Reduced by approx.

More information

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000 D-sub Connector J Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000//000 Number of connectors: pins MIL-C-08 Conforming to JIS-X-0 --6 For details

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Rubber Seal Series VQ Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type1P Type2P 5 Port Solenoid Valve ase Mounted Manifold ar Stock Type/Flat Ribbon Cable Series /5000/000 How to Order Manifold Type 1P/Compact style SS5Y 5 1P 05 C8 Manifold series 3 5, port size Thread

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 0 PW COM Rubber Seal Port Solenoid Valve Series SZ000 Cassette Type Manifold The plug-in cassette system makes valve replacement easy. plug-in manifold has been created with a height of. mm (including

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Series VQ Rubber Seal Space-saving profile Clean space saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector

More information

Example. U side. Stations SY5000

Example. U side. Stations SY5000 45 Type 5 ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN ail Mounted/Individual Wiring Series SY3000/5000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 3 45 05 U C6 Example

More information

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position

More information

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection Rubber Seal Port Solenoid Valve Series SJ000/000 Cassette Type Manifold 0 mm 7. mm (SJ000) 0 mm (SJ000) Non plug-in type Individual wiring manifold SJ000 SJ000 Can be mounted together. Connecter connection

More information

VQ1000. How to Order Manifold. Kit type

VQ1000. How to Order Manifold. Kit type - - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold

More information

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308 Cable ppendix Cable ppendix Multi-way cables The multi-pole connector cables used on SMC valves are common across several ranges. Cables are available in accordance with the MIL standard C-08 and also

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Port Solenoid Valve Metal Seal Rubber Seal Series Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000

More information

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted

More information

SMC guide to ATEX compliant products

SMC guide to ATEX compliant products SMC guide to ATEX compliant products P-E13-23A A ATEX Directive Directive 94/9/EC Equipment and Protective Systems intended for use in potentially Explosive Atmospheres Outline of ATEX directive Since

More information

Single Valve/Sub-plate Type IP67 Compliant 90-SV Series

Single Valve/Sub-plate Type IP67 Compliant 90-SV Series Single Valve/Sub-plate Type IP7 Compliant -SV Series SV 00 W U aterial restriction Series -SV000 -SV000 Thread type c F G N NPT T NPTF A B SOL.a SOL.a Type of actuation position single (EA) (P)(EB) position

More information

Vacuum Release Valve with Restrictor

Vacuum Release Valve with Restrictor INFORMATION Series SY3/5 Plug-in Only for External Pilot Vacuum Release Valve with Vacuum suction and release can be controlled with a single valve! PE Pilot EH port Flow rate adjustment of release air

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1 Port Solenoid Valve Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Non plug-in manifold 0 0 S 60 Stations stations 0 stations SUP/EXH

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring Type4 SY000/000 ase Mounted Monifold Stacking Type/DIN ail Mounted Individual Wiring How to Order Manifold SSY 4 0 U C6 How to Order Valve Manifold ssembly Ordering example SY000 SY000 Valve stations 02

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer Base Mounted Metal Seal/Rubber Seal VQ Built-in silencer, direct exhaust Space-saving profile All pilot valves are compactly mounted on one side. The space-saving design of mounting all fittings on one

More information

Applicable bore size. CC-Link. EtherNet/IP. Decentralized Serial Wiring. EtherCAT I/O. Serial unit: EX600 IP67 compliant. Serial unit: EX500

Applicable bore size. CC-Link. EtherNet/IP. Decentralized Serial Wiring. EtherCAT I/O. Serial unit: EX600 IP67 compliant. Serial unit: EX500 5 Port Solenoid Valve Series C000 Metal Seal Rubber Seal Compact and large flow Type (Series) Manifold pitch (mm) C000 5 6. 0.7.7 7. 0..0 to ø Note) Flow characteristics: position single, / 5/ (/ R/R)

More information

Series SV1000/2000/3000/4000

Series SV1000/2000/3000/4000 Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry

More information

SV1000/2000/3000/4000

SV1000/2000/3000/4000 Decentralized Serial Wiring (GW System, Branches) Series EX00 Valve manifold and input unit manifold can be connected around the GW unit. ompatible with various protocols by replacing the GW unit. ompatible

More information

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

More information

How to Order Manifold. Kit type L8 B4 B6 B8 LM

How to Order Manifold. Kit type L8 B4 B6 B8 LM 0 Stations station VVQ Series VQ000 The maximum and minimum number of are varied depending on. (Refer to the table below.) Series VQ000 ase Mounted Plug-in Unit Manifold Plug-in unit 08 C Cylinder port

More information

New Concept Connector Type Manifold

New Concept Connector Type Manifold New Concept Connector Type Manifold Series /000/3000/000 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration.

More information

Gateway Type Serial Transmission System

Gateway Type Serial Transmission System P99-EX-B Gateway Type Serial Transmission System P Maximum 8 point control (64 inputs/64 outputs) P Flexibility of manifold valve installation improved with 4 branch wiring Flexible installation and removal

More information

F Kit. D-sub. connector. D-sub. connector) Compatible network DeviceNet PROFIBUS DP. CC-Link. Compatible D-sub connector. Output

F Kit. D-sub. connector. D-sub. connector) Compatible network DeviceNet PROFIBUS DP. CC-Link. Compatible D-sub connector. Output Series VQC000 ase Mounted: Variations 5 Port Solenoid Valve Series VQC000 Sonic Conductance C[dm /(s bar)] Values: CYL EXH / 5/ Single/Double position (Closed center) pplicable bore size Compatible network

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

Series SY3000/5000 How to Order Manifold

Series SY3000/5000 How to Order Manifold Type N ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN Rail Mounted/Connector ox SY/ How to Order Manifold SSY SY SY Specifications Symbol Specifications With connector box (COM spec.) N With

More information

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications Series -SQ00 Port Solenoid Valve Plug-in Unit [Option] How to Order Manifold Electrical entry F kit D-sub connector kit P kit SSQ 08 FD Kit type Flat ribbon cable connector kit J kit Flat ribbon cable

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series

More information

Fieldbus System Variations

Fieldbus System Variations Fieldbus System Variations IP67/65 specification models I/O separated type Valve outputs only Inputs only Gateway-type valve outputs only inputs only I/O integrated type Valve outputs with multiple I/O

More information

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal

More information

Series VQZ1000/2000/3000 Single Unit

Series VQZ1000/2000/3000 Single Unit +- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body

More information

Reduced-wiring Fieldbus System (Serial Transmission)

Reduced-wiring Fieldbus System (Serial Transmission) Best Pneumatics 1 Fieldbus System Variations P.2040 Applicable Valve Series P.2042 SV P.2042 SZ P.2042 SY NEW P.2043 SY P.2044 SYJ P.2045 SJ P.2045 VQC P.2046 SQ P.2046 VQ P.2047 VQZ P.2047 P.2048 Reduced-wiring

More information

Vacuum System Peripherals

Vacuum System Peripherals Vacuum System Peripherals Vacuum Regulator/Electronic Vacuum Regulator Vacuum regulator: IRV0/0 Electronic vacuum regulator: ITV009/ITV09 Directional Control Valve Selection guide of directional control

More information

Series PCW. PC Wiring System

Series PCW. PC Wiring System CT.ES0-0 PC Wiring System Series PCW The PC wiring system is a revolutionary new system that simplifies wiring between a PLC and all types of connected equipment. revolutionary new wiring system... 4VDC

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal Port Solenoid Valve Cassette Type Manifold Rubber Seal 7.mm (SJ000) SJ000 SJ000 Can be mounted together. 0mm (SJ000) Connector connection New New cable type manifold is added! New Additional options are

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve ubber Seal / ort Solenoid Valve Series 000 / 000 / 000 [Option] SJ SY SV SZ V S000 VQ VQ VQ VQC VQZ SQ VFS VF VQ Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

Select from 3 product types and 14 protocols.

Select from 3 product types and 14 protocols. Fieldbus System Select from 3 product types and 14 protocols. * Some protocols are not UL-compliant. Type 1 Type 2 Type 3 Output type for solenoid valves Gateway type Integrated input-output type CAT.E02-27A

More information

Series ITV1000/2000/3000

Series ITV1000/2000/3000 Electro-Pneumatic Regulator Series ITV// How to Order [Option] RoHS ITV S Model type type type Pressure range 5 MPa MPa.9 MPa CE compliant Nil Q CE compliant Note) Refer to pages, 5, and 6 for information

More information

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Vacuum Release Valve with Restrictor Series SJ3A6 SJ Plug-in Type Connector Connection P.86 D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Non Plug-in Type Individual

More information

Manifold Specifications

Manifold Specifications Specifications Specifications Base mounted VVFR-01 VVFR- VVFR-0 Wiring With terminal block With multi-connector With D-sub connector Grommet terminal DIN terminal Grommet Grommet terminal Conduit terminal

More information

5 Port Solenoid Valve Plug Lead Type

5 Port Solenoid Valve Plug Lead Type 5 Port Solenoid alve Plug Lead Type Series Body Ported Flow rate characteristics For single/double solenoid C [dm 3 /(s bar)]: 0.6 Single Unit alve width: 7.4 mm Possible to drive cylinders: Up to ø32

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M. V3 Cover

More information

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve CT.E- ase Mounted Type Series VQ Port Metal Seal/Rubber Seal Solenoid Valve dvanced manifold va the new age of factory au ase Mounted Type Space saving profile Clean space saving design with all pilot

More information

Electro-Pneumatic Regulator Electronic Vacuum Regulator

Electro-Pneumatic Regulator Electronic Vacuum Regulator Electro-Pneumatic Regulator Electronic Vacuum Regulator New Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to Series ITV//! Reduced wiring

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

How to Order Manifold. Control unit Refer to pages to Kit/Electrical entry/cable length. kit (D-sub connector) U0 U1 U2

How to Order Manifold. Control unit Refer to pages to Kit/Electrical entry/cable length. kit (D-sub connector) U0 U1 U2 VQ000 ase Mounted Plug-in nit For details aout certified products conforming to international standards, visit us at www.smcworld.com. Type of connection VVQ VQ000 R port P port Port R Manifold Plug-in

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000) 5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust

More information

Gateway System Serial Transmission System

Gateway System Serial Transmission System Gateway System Series 00 I compliant V S000 C Tie-rod base Z pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000/000/000 Number of output points: points Connected to the 00GW

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators

More information

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A Type N SY/ ase ounted anifold Stacking Type/DIN Rail ounted Connector ox How to Order anifold SSY SY SY Specifications Symbol Specifications With connector box (CO spec.) N With connector box ( CO spec.)

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to New Series Reduced wiring Series

More information

Manifold Specifications

Manifold Specifications Series 00 Manifold Specifications Manifold Specifications Model Manifold type P(SUP)/R(EXH) Valve stations A port porting specifications Port size For internal pilot For external pilot Location Direction

More information

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold Compact Electro-Pneumatic Regulator Series ITV How to Order For single unit and single unit for manifold ITV N Q Pressure range. MPa MPa.9 MPa Power supply voltage 4 VDC ±% to VDC Cable connector N S L

More information

Information mm. 81 mm

Information mm. 81 mm Compatible Communication Protocol eviceet POFIUS P Each -output/-output type available in the series Each negative common (PP) / positive common (P) type available in the series uilt-in terminator switch

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high

More information

How to Order Manifold. Option Symbol

How to Order Manifold. Option Symbol Series Plug Lead nit For details about certified products conforming to international standards, visit us at www.smcworld.com. Series/Manifold 12 Stations 01 1 station Kit/Electrical entry/cable length

More information

0.35 W (Without light)

0.35 W (Without light) Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid alve Plug Lead Type RoHS New Body Ported Flow-rate characteristics For single/double solenoid C [dm 3 /(s bar)]: 0.6 Single Unit alve width: 7. mm Possible to drive cylinders: Up to ø32

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

5 Port Air Operated Valve

5 Port Air Operated Valve Port ir Operated Valve Series VF000/000/000 RoHS 22- Series VF000/000/000 Model Selection by Operating Conditions q ir Operated Valve: Single Unit Series Sonic conductance C[dm /(s bar)] Type of actuation

More information

Non-Contact Sensor for Workpiece Placement Verification

Non-Contact Sensor for Workpiece Placement Verification ir Catch Sensor Series 2 Non-Contact Sensor for Workpiece Placement Verification Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact

More information

3 Port Air Operated Valve

3 Port Air Operated Valve Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating / ort Solenoid Valve ubber Seal Series SYJ000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Specifications JIS Symbol port port (manifold) position

More information

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC Base Mounted Series VQZ00/00/00 VQZ00/00 / How to Order Valve Made to Order (For details, refer to page 9 and 4.) VQZ 5 5 M Series VQZ00 body width 5 mm VQZ00 body width 8 mm Type of actuation 4 N.C. N.O.

More information

Electro-Pneumatic Regulator/Electronic Vacuum Regulator

Electro-Pneumatic Regulator/Electronic Vacuum Regulator Electro-Pneumatic Regulator/Electronic Vacuum Regulator Series Stepless control of air pressure proportional to an electrical signal // series are compatible with various input specifications, including

More information

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing

More information

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Body Ported Base Mounted Series S000 S000 S000 S000 S000 S4000 S5000 Sonic conductance C [dm /s bar)] 4/ 5/(A/B R/R) Single Double.8.4

More information

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot ubber seal ort ilot Solenoid Valve Series SYJ00 Specifications efer to www.smcworld.com for details of products compatible with overseas standards. Body ported Base mounted Fluid Operating pressure range

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is. Port Solenoid Valve Series VQ 00 Unprecedented high speed, stable response, and extra-long service life. ON:.ms, OFF: ms, Dispension accuracy ±ms (With indicator light and surge voltage suppressor; supply

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

3 Port 3 Position Valve

3 Port 3 Position Valve Port Position Valve Pilot Solenoid ir Operated ohs Intermediate stopping of cylinders * up to ø15 is possible. Pilot solenoid Manifold ir operated * For VEX 4, 00 mm/s, horizontal movement Power consumption:

More information

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold Port Solenoid Valve VV00 Series Highly Integrated Unit Manifold po ted - pera irect-o d station es on rt valv ally ividu Ind wired n be ve ca val d. adde ector Con-inn connection) lug (For p ø connection

More information

5 Port Solenoid Valve Series SV

5 Port Solenoid Valve Series SV CT.S- -UK ort Solenoid Valve Series SV New Concept Type Manifold Series SV000/000/000/000 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 044 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000 racket

More information