Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

Size: px
Start display at page:

Download "Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications"

Transcription

1 Series -SQ00 Port Solenoid Valve Plug-in Unit [Option] How to Order Manifold Electrical entry F kit D-sub connector kit P kit SSQ 08 FD Kit type Flat ribbon cable connector kit J kit Flat ribbon cable (0P) (PC wiring system compatible) kit Note ) S kit ead wire kit Clean series 0 Serial transmission kit EX0 Integrated-type (For Output) Serial Transmission System Stations station Note) stations Note) The maximum number of stations depends on the type of electrical entries. 6P ( 0P ) Manifold mounting D DIN rail mounting E Direct mounting D, (R) port size FD0 FD FD FD PD0 PD PD PD PDC JD0 ead wire connector location Note ) D0 (N) U0 (N) D (N) U (N) D (N) U (N) SDF SDH SDJ SDJ SDQ SDR SDR SDV Option Nil 0 to B Note ) K Note ) N Nil Cable/SI unit specifications D-sub connector kit, without cable D-sub connector kit, with. m cable D-sub connector kit, with.0 m cable D-sub connector kit, with.0 m cable Flat ribbon cable (6P) kit, without cable Flat ribbon cable (6P) kit, with. m cable Flat ribbon cable (6P) kit, with.0 m cable Flat ribbon cable (6P) kit, with.0 m cable Flat ribbon cable (0P) kit, without cable Flat ribbon cable (0P) PC wiring system compatible ead wire kit with 0.6 m cable ead wire kit with. m cable ead wire kit with.0 m cable 00T Note ) NKE Corp.: Fieldbus System NKE Corp.: Fieldbus H System Panasonic Industrial Devices SUNX Co., td.: S-INK (6 output points) Panasonic Industrial Devices SUNX Co., td.: S-INK (8 output points) DeviceNet OMRON Corp.: CompoBus/S (6 output points) OMRON Corp.: CompoBus/S (8 output points) CC-ink CE-compliant Nil Q CE-compliant, (R) port ø8 s, (R) port ø/6" s None DIN rail length specified Back pressure check valve Special wiring specifications (Except double wiring) With name plate (Side ported only) Note ) Specify DIN rail length with D at the end. (Enter the number of stations inside.) The number of stations that may be displayed is longer than the manifold number of stations. Example: -D09 Note ) When -B is selected, a back pressure check valve is included in all stations of the manifold. If the back pressure check valve is used only for the station that need it, then specify the station location in the manifold specification. ( -B is not necessary) Note ) Specify -K for wiring specification for cases below. (Except kit) - ll single wiring - Single and double mixed wiring. - When there are stations which do not require wiring (e.g. individual SUP spacer), specify the wiring specification in the manifold specification so that the number of solenoids is the maximum number of solenoids or less. (Standard wiring specification is double wiring) Note ) For specifying two or more options, enter them alphabetically. Example: -BKN Station (Double wiring) to 9 stations to 8 stations to 8 stations to stations to 8 stations to stations to 8 stations Max. number of solenoids for special wiring specifications Note ) CEcompliant Note ) Separately order the 0P type cable assembly for the P kit. Note ) Specify the wiring so that the maximum number of solenoids is not exceeded. (The number of solenoids are counted as: for single solenoids and for type P double solenoids.) Note ) When specifying the negative common specifications of the kit, suffix N to the kit symbol. 78

2 Port Solenoid Valve/Plug-in Unit -SQ00 How to Order Valve ctuation type SQ Clean series Seal Rubber seal position single () (B) (R) (R) position double (Double solenoid) Note) () (B) (R) (R) Rubber seal position closed center () (B) (R) (R) position exhaust center () (B) (R) (R) position pressure center () (B) (R) (R) Note) For double solenoid specification, the function symbol below is D. Function Symbol Specifications Nil Standard type (0. W) B Quick response type (0.9 W) Manual D Note ) position double (Double solenoid specifications) N Note ) Negative common Note ) D is specified for position double. Note ) For kit, when the manifold specifies negative common, the valve common should also be negative. The combination of negative common of the valve cannot be specified with S kit (EX0). Note ) When two or more symbols are specified, indicate them alphabetically. C6 [Option] Cylinder port Symbol Port size Port location C C C6 M 6 override Nil Non-locking push type (Tool required) Manifold block Nil Without manifold block Port plug mounting port Nil None Port () B Port (B) With ø. s With ø s With ø6 s M thread With ø. s With ø s With ø6 s M thread CE-compliant Nil Q CE-compliant ead wire is not included. When ordering with manifolds When only valves are required. Side ported Note) Top ported Note) Can be changed to side ported configuration. B ocking type (Tool required) M MB With manifold block, With manifold block built-in back pressure check valve ead wire is not included. For adding stations Rated voltage 6 VDC VDC Note ) ight/surge voltage suppressor is built-in. Note ) S kit: VDC only 79

3 Port Solenoid Valve/Plug-in Unit -SQ00 How to Order Manifold ssembly (Example) Example) D-sub connector kit, with cable ( m) position single ( VDC) -SQ0--C6 ( sets) m D-sub connector cable XT0-DS-00 F kit (D-sub connector kit) position double ( VDC) -SQ0D--C6 ( sets) Stations SSQ-09FD-D set (F kit 9-station manifold base) -SQ0--C6 sets ( position single) -SQ0D--C6 sets ( position double) SSQ00-- set (Blanking plate) Cylinder port fitting C6 Manifold base (9 stations) -SSQ-09FD-D The asterisk denotes the symbol for assembly. Prefix it to the part no. of the solenoid valve, etc. dd the valve and option part numbers in order starting from the first station on the. When entry of part numbers becomes complicated, indicate on the manifold specification sheet. Blanking plate SSQ00-- ( set) 80

4 Port Solenoid Valve/Plug-in Unit -SQ00 Model Series SQ00 position position ctuation type Single Double Closed center Exhaust center Pressure center Seal Model Rubber seal -SQ Rubber seal -SQD Rubber seal -SQ Rubber seal -SQ Rubber seal -SQ Flow rate characteristics Note ) / (P /B) ( R) C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv Response time (ms) Note ) Standard (0. W) or less 0 or less 9 or less 9 or less 9 or less Quick response (0.9 W) or less or less or less or less or less Note ) Values for the cylinder port size of C6, CY Values of EXH. Flow rate characteristics of (B R) declines about 0% of ( R). Note ) Based on JIS B (Values with a supply pressure of 0. MPa and light/surge voltage suppressor. Values fluctuate depending on the pressure and air quality. Weight (g) Specifications Valve construction Fluid Maximum operating pressure Valve specifications Solenoid specifications Single Double (Double solenoid) position mbient and fluid temp. ubrication Pilot valve manual override Min. operating pressure Vibration/Impact resistance Note ) Protection structure Coil rated voltage llowable voltage fluctuation Coil insulation type Power consumption (Current) VDC VDC Rubber seal ir 0.7 MPa 0. MPa 0. MPa 0. MPa to 0 C Note ) Not required Push type/ocking type (Tool required) 0/0 m/s Dust tight VDC, VDC ±% of rated voltage Equivalent to class B 0. W DC (7 m), 0.9 W DC (0 m) Note ) 0. W DC ( m), 0.9 W DC (80 m) Note ) Note ) Use dry air to prevent condensation when operating at low temperatures. Note ) Vibration resistance: No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed in both energized and de-energized states in the axial direction and at right angles to the main valve and armature. (Default settings) Impact resistance: No malfunction occurred when it was tested with a drop tester in the axial direction and at right angles to the main valve and armature in both energized and deenergized states once for each condition. Note ) Value for quick response type Symbol position single position double (Double solenoid) position closed center position exhaust center position pressure center () (B) () (B) () (B) () (B) () (B) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) Manifold Specifications Base model -SSQ- - P, R C8 (For ø8) Piping specifications Note ) Port size Port location Side Note ) Top, B Port size C (For ø.) C (For ø) C6 (For ø6) M (M thread) (For ø.) (For ø) 6 (For ø6) (M thread) pplicable solenoid valve Note ) s in inch sizes are also available. Note ) Can be changed to side ported configuration. Note ) n optional specification for special wiring is available to increase the maximum number of stations. Note ) Except valves. 8 Connection type Note ) pplicable stations F kit: D-sub connector P kit: Flat ribbon cable 6P 0P to 9 stations -SQ J kit: Flat ribbon cable to 8 stations PC wiring system compatible kit: ead wire S kit: Serial transmission to 8 stations Note ) station weight (g) Note ) station weight (g)

5 Port Solenoid Valve/Plug-in Unit -SQ00 F Kit (D-sub connector) (8.) (Mounting hole dimension) pplicable connector: D-sub connector (Conforming to MI-C-08) ( position). (Double) 8. (Single) Release for switching connector direction [(R), port] pplicable tubing O.D.: ø8 7.8 P=. Stations R P. 8. P= n Indicator light Manual override 7. 60, thread piping [(), (B) port] pplicable tubing O.D.: ø. : ø Thread size: M 7. x M DIN rail clamp screw n Formula =.n +. =.n + 7 n: Stations (Max. stations)

6 Port Solenoid Valve/Plug-in Unit -SQ00 P Kit (Flat ribbon cable connector) (Mounting hole dimension). 7.8 P= Indicator light Manual override 8.. ( position). (Double) 8. (Single) pplicable connector: Flat ribbon cable connector (6P) (Conforming to MI-C-80) Triangle mark indicator position x M DIN rail clamp screw Release for switching connector direction Stations n [(R), port] pplicable tubing O.D.: ø8 R P P=., thread piping [(), (B) port] pplicable tubing O.D.: ø. : ø Thread size: M n Formula =.n +. =.n + 7 n: Stations (Max. stations)

7 Port Solenoid Valve/Plug-in Unit -SQ00 J Kit (PC wiring system compatible flat ribbon cable) (8.) (Mounting hole dimension) pplicable connector: Flat ribbon cable connector (0P) (Conforming to MI-C-80) ( position). (Double) 8. (Single) Triangle mark indicator position Release for switching connector direction [(R), port] pplicable tubing O.D.: ø Stations R P P=. P= n, thread piping [(), (B) port] pplicable tubing O.D.: ø. : ø Thread size: M Indicator light Manual override x M DIN rail clamp screw n Formula =.n +. =.n + 7 n: Stations (Max. 6 stations)

8 Port Solenoid Valve/Plug-in Unit -SQ00 Kit (ead wire cable) Electrical entry G/ (Mounting hole dimension) Station number WG ead wire P=. 9.. Indicator light Manual override (8.) ( position). (Double) 8. (Single) x M DIN rail clamp screw Stations n ead wire length: 0, 0.6 m,. m,.0 m [(R), port] pplicable tubing O.D.: ø8 R (9.) 9.6. P P=., thread piping [(), (B) port] pplicable tubing O.D.: ø. : ø Thread size: M n Formula =.n +. =.n + 9 n: Stations (Max. stations)

9 Port Solenoid Valve/Plug-in Unit -SQ00 (8.) S Kit (Serial transmission unit) (Single). (Double) ( position) (9.) No. BS+ BDH BD BS- FG V 0V SERI UNIT EX0-SCS [(R), port] pplicable tubing O.D.: ø8 7. PWR. COMM ERR. DDRESS No P=. Stations R P P=. 6 7 x M DIN rail clamp screw n Indicator light.7 8. Manual override 6. 7, thread piping [(), (B) port] pplicable tubing O.D.: ø. : ø Thread size: M n 78. Formula =.n + 67 =.n n: Stations (Max. 6 stations)

10 Series -SQ000 How to Order Manifold Port Solenoid Valve Plug-in Unit [Option] SSQ 08 FD D Clean series CE-compliant Nil Stations Q CE-compliant 0 station, (R) port size FD0 D-sub connector kit, without cable F kit FD D-sub connector kit, with. m cable FD D-sub connector kit, with.0 m cable D-sub connector kit FD D-sub connector kit, with.0 m cable 6 stations 6 Note) 6 stations, (R) port Nil Note) The maximum number of ø s stations depends on the, (R) port 00T type of electrical entries. ø/8" s Option Manifold mounting Nil None 0 to 6 Note ) DIN rail length specified D DIN rail mounting B Note ) Back pressure check valve E Direct mounting K Note ) Special wiring specifications (Except double wiring) N With name plate (Side ported only) Note ) Specify DIN rail length with D at the end. (Enter the number of stations inside.) The number of stations that may be displayed is longer than the manifold number of stations. Example: -D09 Note ) When -B is selected, a back pressure check valve is included in all stations of the manifold. If the back pressure check valve is used only for the station that need it, then specify the station location in the manifold specification. ( -B is not necessary) Note ) Specify -K for wiring specification for cases below. (Except kit) - ll single wiring - Single and double mixed wiring. - When there are stations which do not require wiring (e.g. individual SUP spacer), specify the wiring specification in the manifold specification so that the number of solenoids is the maximum number of solenoids or less. (Standard wiring specification is double wiring) Note ) For specifying two or more options, enter them alphabetically. Example: -BKN Electrical entry Kit type ead wire Station Max. number of Max. number of CEcompliant connector Cable/SI unit specifications stations for special solenoids for special location (Double wiring) wiring specifications wiring specifications Note ) PD0 Flat ribbon cable (6P) kit, without cable P kit PD Note ) Flat ribbon cable (6P) kit, with. m cable PD Flat ribbon cable (6P) kit, with.0 m cable 6 stations PD Flat ribbon cable (6P) kit, with.0 m cable 6P Flat ribbon cable connector kit 0P PDC Flat ribbon cable (0P) kit, without cable to 9 stations 8 J kit Flat ribbon cable (0P) JD0 Flat ribbon cable (0P) PC wiring system compatible (PC Wiring System compatible) to 8 stations 6 stations 6 T kit TD0 Terminal block box kit to stations 6 stations 0 Terminal block box kit D0 (N) kit ead wire kit with 0.6 m cable Note ) U0 (N) D (N) ead wire kit with. m cable U (N) D (N) ead wire kit with.0 m cable ead wire kit U (N) Note SDF NKE Corp.: Fieldbus System S kit SDH NKE Corp.: Fieldbus H System to 8 stations 6 stations 6 SDJ Panasonic Industrial Devices SUNX Co., td.: S-INK (6 outputs) SDJ Panasonic Industrial Devices SUNX Co., td.: S-INK (8 outputs) to stations 8 stations 8 SDQ DeviceNet to 8 stations 6 stations 6 SDR OMRON Corp.: CompoBus/S (6 outputs) Serial transmission kit EX0 Integrated-type (For Output) SDR OMRON Corp.: CompoBus/S (8 outputs) to stations 8 stations 8 Serial Transmission System SDV CC-ink to 8 stations 6 stations 6 ) Separately order the 0P type cable assembly for the P kit. Note ) Specify the number of the solenoid so that the maximum station number is not exceeded.(the number of solenoids are counted as: for single solenoids and for type P double solenoids.) Note ) When specifying the negative common specifications of the kit, suffix N to the kit symbol. For details, refer to the WEB catalog. 87

11 Port Solenoid Valve/Plug-in Unit -SQ000 How to Order Valve SQ Clean series C6 CE-compliant Nil Q CE-compliant [Option] Seal Rubber seal ctuation type position single () (B) (R) (R) position double (Double solenoid) Note) () (B) (R) (R) Rubber seal position closed center () (B) (R) (R) position exhaust center () (B) (R) (R) position pressure center () (B) (R) (R) Note) For double solenoid specification, the function symbol below is D. Function Symbol Specifications Nil Standard type (0. W) B Quick response type (0.9 W) D Note ) position double (Double solenoid specifications) N Note ) Negative common Note ) D is specified for position double. Note ) For kit, when the manifold specifies negative common, the valve common should also be negative. The combination of negative common of the valve cannot be specified with S kit (EX0). Note ) When two or more symbols are specified, indicate them alphabetically. Rated voltage 6 Manual override Nil VDC VDC Cylinder port Symbol Port size C C6 C8 6 8 Non-locking push type (Tool required) Manifold block Nil Without manifold block Port plug mounting port Nil None Port () B Port (B) With ø s With ø6 s With ø8 s With ø s With ø6 s With ø8 s B ocking type (Tool required) Note ) ight/surge voltage suppressor is built-in. Note ) S kit: VDC only ead wire is not included. When ordering with manifolds When only valves are required. Side ported Port location Note) Can be changed to side ported configuration. M With manifold block Note) Top ported MB With manifold block, built-in back pressure check valve ead wire is not included. For adding stations D Slide locking type (Manual type) Only side ported applicable 88

12 Port Solenoid Valve/Plug-in Unit -SQ000 How to Order Manifold ssembly (Example) Example) D-sub connector kit, with cable ( m) position single ( VDC) -SQ0--C8 ( sets) m position double ( VDC) -SQ0D--C8 ( sets) Stations position closed center ( VDC) -SQ0--C8 ( set) Blanking plate SSQ000-- ( set) D-sub connector cable XT0-DS-00 F kit (D-sub connector kit) Manifold base (8 stations) -SSQ-08FD-D Cylinder port fitting C8: ø8 s -SSQ-08FD-D set (F kit 8-station manifold base) -SQ0--C8 sets ( position single) -SQ0D--C8 sets ( position double) -SQ0--C8 set ( position closed center) SSQ000-- set (Blanking plate) The asterisk denotes the symbol for assembly. Prefix it to the part no. of the solenoid valve, etc. dd the valve and option part numbers in order starting from the first station on the. When entry of part numbers becomes complicated, indicate on the manifold specification sheet. 89

13 Port Solenoid Valve/Plug-in Unit -SQ000 Model Series SQ000 position position ctuation type Single Double Closed center Exhaust center Pressure center Flow rate characteristics Note ) Seal Model / (P /B) / / (/B R/R) C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv Rubber seal -SQ Rubber seal -SQD Rubber seal -SQ Rubber seal -SQ Rubber seal -SQ Specifications Valve construction Fluid Maximum operating pressure Single Double (Double solenoid) position mbient fluid temperature to 0 C Note ) ubrication Not required Pilot valve manual override Push type (Tool required)/ocking type (Tool required)/slide locking type (Manual) Vibration/Impact resistance Note ) 0/0 m/s Protection structure Dust tight Coil rated voltage VDC, VDC llowable voltage fluctuation ±% of rated voltage Coil insulation type Equivalent to class B Power consumption (Current) VDC VDC Response time (ms) Note ) Weight Standard (0. W) or less or less 6 or less 0 or less or less or less or less or less or less or less Note ) Values for the top ported cylinder port size of C8. CY Values of EXH. The side ported type will be about % less. Note ) Based on JIS B (Values with a supply pressure of 0. MPa and light/surge voltage suppressor. Values fluctuate depending on the pressure and air quality.) Symbol (R) (R) Rubber seal ir 0.7 MPa 0. MPa 0. MPa 0. MPa Quick response (0.9 W) (g) W DC (7 m), 0.9 W DC (0 m) Note ) 0. W DC ( m), 0.9 W DC (80 m) Note ) Note ) Use dry air to prevent condensation when operating at low temperatures. Note ) Vibration resistance: No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed in both energized and de-energized states in the axial direction and at right angles to the main valve and armature. (Default settings) Impact resistance: No malfunction occurred when it was tested with a drop tester in the axial direction and at right angles to the main valve and armature in both energized and de-energized states once for each condition. Note ) Value for quick response type. position single position double (Double solenoid) position closed center position exhaust center position pressure center () (B) () (B) () (B) () (B) () (B) Manifold Specifications Base model Series -SQ000 -SSQ- - P, R C (For ø) (R) (R) Piping specifications Note ) Port size Port location Side Note ) Top Valve specifications Solenoid specifications, B Port size Min. operating pressure C (For ø) C6 (For ø6) C8 (For ø8) C (For ø) C6 (For ø6) C8 (For ø8) (R) (R) pplicable solenoid valve Note ) s in inch sizes are also available. Note ) Can be changed to side ported configuration. Note ) n optional specification for special wiring is available to increase the maximum number of stations. Note ) Except valves. (R) (R) Connection type F kit: D-sub connector P kit: Flat ribbon cable 6P 0P to 9 stations -SQ J kit: Flat ribbon cable PC wiring system compatible. Kit: ead wire S Kit: Serial transmission to 8 stations to 8 stations (R) (R) Note ) Note ) Note ) stations station pplicable weight weight stations (g) (g)

14 Port Solenoid Valve/Plug-in Unit -SQ000 F Kit (D-sub connector) 8. (Mounting hole dimension) 8.. Release for switching connector direction 7.8 P= Indicator light Manual override (.) SMC 7 ( position). (Single, Double) B x M DIN rail clamp screw pplicable connector: D-sub connector (Conforming to MI-C-08) Stations n [(R), port] pplicable tubing O.D.: ø R (8.) B B B B B B B B P P=7. [(), (B) port] pplicable tubing O.D.: ø : ø8 n Formula: = 7.n +, = 7.n + 7. n: Stations (Max. 6 stations)

15 Port Solenoid Valve/Plug-in Unit -SQ000 P Kit (Flat ribbon cable) 8. (Mounting hole dimension) (.) SMC 8. 7 ( position). (Single, Double). pplicable connector: Flat ribbon cable connector (6P) (Conforming to MI-C-80) Release for switching connector direction.9 Triangle mark indicator position... [(R), port] pplicable tubing O.D.: ø (8.) P= Stations n R P B B B P=7. B B B B B B Indicator light Manual override x M DIN rail clamp screw [(), (B) port] pplicable tubing O.D.: ø : ø8 n Formula: = 7.n +, = 7.n + 7. n: Stations (Max. 6 stations)

16 Port Solenoid Valve/Plug-in Unit -SQ000 J Kit (PC wiring system compatible flat ribbon cable) 8. (Mounting hole dimension) 8. Release for switching connector direction. 7.8 P= Indicator light Manual override.9 8. (.) 7 ( position). (Single, Double) SMC x M DIN rail clamp screw B Triangle mark indicator position pplicable connector: Flat ribbon cable connector (0P) (Conforming to MI-C-80) Stations n [(R), port] pplicable tubing O.D.: ø R (8.) B B B B B B B B P P=7. [(), (B) port] pplicable tubing O.D.: ø : ø8 n Formula: = 7.n +, = 7.n + 7. n: Stations (Max. 6 stations)

17 Port Solenoid Valve/Plug-in Unit -SQ000 T Kit (Terminal block box) (.) ( position). (Single, Double)..9. [(R), port] pplicable tubing O.D.: ø x G /" Electrical entry (77) P= Stations n R P P=7. B Indicator light Manual override x M DIN rail clamp screw [(), (B) port] pplicable tubing O.D.: ø : ø8 n DIN rail mounting Direct mounting Formula: = 7.n + 6, = 7.n + 60 n: Stations (Maximum 6 stations)

18 Port Solenoid Valve/Plug-in Unit -SQ000 Kit (ead wire) (Mounting hole. dimension) Electrical entry G / (.) ( position). (Single, Double) SMC Station number WG ead wire 8.8 P= Indicator light Manual override x M DIN rail clamp screw B [(R), port] pplicable tubing O.D.: ø Stations n ead wire length: 0, 0.6 m,. m,.0 m R (8) B B B B B B B B P P=7. [(), (B) port] pplicable tubing O.D.: ø : ø8 Formula: = 7.n + 6, = 7.n + 60 n: Stations (Max. stations) n

19 Port Solenoid Valve/Plug-in Unit -SQ000 S Kit (Serial transmission) (.) 8. 7 ( position). (Single, Double).9 (8) [(R), port] pplicable tubing O.D.: ø 7. V 0 0V +V G D DB DG FG SI unit SERI UNIT EX0-SMJ ERR. SD RD PWR. RUN B RTE STTION No P= Stations n R P B B B P=7. B B B B B B Indicator light Manual override x M DIN rail clamp screw [(), (B) port] pplicable tubing O.D.: ø : ø8 n 69. Formula: = 7.n +, = 7.n + 6 n: Stations (Max. 6 stations)

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),

More information

VQ1000. How to Order Manifold. Kit type

VQ1000. How to Order Manifold. Kit type - - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold

More information

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer Base Mounted Metal Seal/Rubber Seal VQ Built-in silencer, direct exhaust Space-saving profile All pilot valves are compactly mounted on one side. The space-saving design of mounting all fittings on one

More information

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Series VQ Rubber Seal Space-saving profile Clean space saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Port Solenoid Valve Metal Seal Rubber Seal Series Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Rubber Seal Series VQ Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

How to Order Manifold. Kit type L8 B4 B6 B8 LM

How to Order Manifold. Kit type L8 B4 B6 B8 LM 0 Stations station VVQ Series VQ000 The maximum and minimum number of are varied depending on. (Refer to the table below.) Series VQ000 ase Mounted Plug-in Unit Manifold Plug-in unit 08 C Cylinder port

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type20P 5 Port Solenoid Valve ody Ported Manifold ar Stock Type/Flat Ribbon Cable Series SY3000/5000/7000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 5 20P 05 Manifold series 3 SY3000

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 0 PW COM Rubber Seal Port Solenoid Valve Series SZ000 Cassette Type Manifold The plug-in cassette system makes valve replacement easy. plug-in manifold has been created with a height of. mm (including

More information

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

0.35 W (Without light)

0.35 W (Without light) Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:

More information

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve CT.E- ase Mounted Type Series VQ Port Metal Seal/Rubber Seal Solenoid Valve dvanced manifold va the new age of factory au ase Mounted Type Space saving profile Clean space saving design with all pilot

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

Manifold Specifications

Manifold Specifications Specifications Specifications Base mounted VVFR-01 VVFR- VVFR-0 Wiring With terminal block With multi-connector With D-sub connector Grommet terminal DIN terminal Grommet Grommet terminal Conduit terminal

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type1P Type2P 5 Port Solenoid Valve ase Mounted Manifold ar Stock Type/Flat Ribbon Cable Series /5000/000 How to Order Manifold Type 1P/Compact style SS5Y 5 1P 05 C8 Manifold series 3 5, port size Thread

More information

Series VQZ1000/2000/3000 Single Unit

Series VQZ1000/2000/3000 Single Unit +- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

More information

5 Port Solenoid Valve Plug Lead Type

5 Port Solenoid Valve Plug Lead Type 5 Port Solenoid alve Plug Lead Type Series Body Ported Flow rate characteristics For single/double solenoid C [dm 3 /(s bar)]: 0.6 Single Unit alve width: 7.4 mm Possible to drive cylinders: Up to ø32

More information

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot ubber seal ort ilot Solenoid Valve Series SYJ00 Specifications efer to www.smcworld.com for details of products compatible with overseas standards. Body ported Base mounted Fluid Operating pressure range

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 044 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000 racket

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry TEX Compliant Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 44 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection Rubber Seal Port Solenoid Valve Series SJ000/000 Cassette Type Manifold 0 mm 7. mm (SJ000) 0 mm (SJ000) Non plug-in type Individual wiring manifold SJ000 SJ000 Can be mounted together. Connecter connection

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve ubber Seal / ort Solenoid Valve Series 000 / 000 / 000 [Option] SJ SY SV SZ V S000 VQ VQ VQ VQC VQZ SQ VFS VF VQ Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

CAT.E152-5 Port Solenoid Valve/Body Ported Cassette Type Manifold. Series SZ3000

CAT.E152-5 Port Solenoid Valve/Body Ported Cassette Type Manifold. Series SZ3000 CAT.E- Port Solenoid Valve/Body Ported Cassette Type Manifold Series SZ000 The plug-in cassette system makes valve replacement easy. A plug-in manifold has been realized having a manifold height of.mm

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to

More information

Fieldbus System (Output device for driving 5 port solenoid valves)

Fieldbus System (Output device for driving 5 port solenoid valves) Fieldbus System (Output device for driving port solenoid valves) New Compact 8mm (ctual size) Space-saving Installation IP67 RoHS EtherNet/IP added! For units with D-sub connector, and when connected to

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

How to Order Manifold. Option Symbol

How to Order Manifold. Option Symbol Series Plug Lead nit For details about certified products conforming to international standards, visit us at www.smcworld.com. Series/Manifold 12 Stations 01 1 station Kit/Electrical entry/cable length

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal Port Solenoid Valve Cassette Type Manifold Rubber Seal 7.mm (SJ000) SJ000 SJ000 Can be mounted together. 0mm (SJ000) Connector connection New New cable type manifold is added! New Additional options are

More information

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000 D-sub Connector J Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000//000 Number of connectors: pins MIL-C-08 Conforming to JIS-X-0 --6 For details

More information

Series SV1000/2000/3000/4000

Series SV1000/2000/3000/4000 Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double

More information

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308 Cable ppendix Cable ppendix Multi-way cables The multi-pole connector cables used on SMC valves are common across several ranges. Cables are available in accordance with the MIL standard C-08 and also

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M. V3 Cover

More information

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is. Port Solenoid Valve Series VQ 00 Unprecedented high speed, stable response, and extra-long service life. ON:.ms, OFF: ms, Dispension accuracy ±ms (With indicator light and surge voltage suppressor; supply

More information

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating / ort Solenoid Valve ubber Seal Series SYJ000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Specifications JIS Symbol port port (manifold) position

More information

Conforms to ISO Standard Size 18 mm, 26 mm Plug-in Type. 5 Port Solenoid Valve

Conforms to ISO Standard Size 18 mm, 26 mm Plug-in Type. 5 Port Solenoid Valve Conforms to IO 0- tandard ize mm, mm Plug-in Type Port olenoid Valve eries V -/V - R R [Option] eries V R- eries V R- Conforms to IO 0- tandard IO tandard: Interface conforming to mm size (V -) and mm

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series

More information

5 Port Air Operated Valve

5 Port Air Operated Valve Port ir Operated Valve Series VF000/000/000 RoHS 22- Series VF000/000/000 Model Selection by Operating Conditions q ir Operated Valve: Single Unit Series Sonic conductance C[dm /(s bar)] Type of actuation

More information

Base Mounted Plug-in/Plug Lead: Single Unit

Base Mounted Plug-in/Plug Lead: Single Unit ase mounted VQ ase Mounted lug-in/lug Lead: Single Unit Model Number of solenoids Model Single Metal seal VQ Rubber seal VQ ouble Metal seal VQ Rubber seal VQ Closed Metal seal VQ VQ center Rubber seal

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid alve Plug Lead Type RoHS New Body Ported Flow-rate characteristics For single/double solenoid C [dm 3 /(s bar)]: 0.6 Single Unit alve width: 7. mm Possible to drive cylinders: Up to ø32

More information

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1 Port Solenoid Valve Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Non plug-in manifold 0 0 S 60 Stations stations 0 stations SUP/EXH

More information

Series PCW. PC Wiring System

Series PCW. PC Wiring System CT.ES0-0 PC Wiring System Series PCW The PC wiring system is a revolutionary new system that simplifies wiring between a PLC and all types of connected equipment. revolutionary new wiring system... 4VDC

More information

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000) 5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust

More information

3 Port Solenoid Valve

3 Port Solenoid Valve 3 ort Solenoid Valve Series VKF300 ubber Seal Direct Operated oppet Type Compact yet provides a large flow capacity Body width 8 mm vailable in vacuum applications ( 0. ka) Can be used in vacuum/release

More information

Base Mounted Plug-in Unit

Base Mounted Plug-in Unit For details about certified products conforming to international standards, visit us at www.smcworld.com. Plug-in Unit SI unit COM N VVQC VVQC C C C6 M CM 6 B B B6 B M Series VQC Manifold model Plug-in

More information

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I ISO Standard Solenoid Valve Series VQ7-6/7-8 (Size ) (Size ) Conforms to ISO Standard /I.0- Ideal for driving cylinders up to Large flow capacity ø00 (VQ7-6, Size ) ø60 (VQ7-8, Size ) Nl/min VQ7-6: 668.

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable

More information

3 Port Air Operated Valve. SYJA300 Series. How to Order. Nil Without sub-plate. Type of actuation. Normally closed Normally open

3 Port Air Operated Valve. SYJA300 Series. How to Order. Nil Without sub-plate. Type of actuation. Normally closed Normally open 3 ort ir Operated Valve SYJ300 Series How to Order SYJ3 M3 Bracket Nil Without bracket F With bracket *The bracket is not mounted. *The bracket cannot be retrofitted later. SYJ3 Type of actuation Normally

More information

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring Type4 SY000/000 ase Mounted Monifold Stacking Type/DIN ail Mounted Individual Wiring How to Order Manifold SSY 4 0 U C6 How to Order Valve Manifold ssembly Ordering example SY000 SY000 Valve stations 02

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position

More information

New Concept Connector Type Manifold

New Concept Connector Type Manifold New Concept Connector Type Manifold Series /000/3000/000 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration.

More information

F Kit. D-sub. connector. D-sub. connector) Compatible network DeviceNet PROFIBUS DP. CC-Link. Compatible D-sub connector. Output

F Kit. D-sub. connector. D-sub. connector) Compatible network DeviceNet PROFIBUS DP. CC-Link. Compatible D-sub connector. Output Series VQC000 ase Mounted: Variations 5 Port Solenoid Valve Series VQC000 Sonic Conductance C[dm /(s bar)] Values: CYL EXH / 5/ Single/Double position (Closed center) pplicable bore size Compatible network

More information

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type. Series -S00 ompact Direct Operated Port Solenoid Valve ontrol Valves ase mounted ody ported lean Series lean Series V S R oil voltage 24 VD VD VD VD VD Power consumption Pressure specification Flow rate

More information

How to Order Manifold. Control unit Refer to pages to Kit/Electrical entry/cable length. kit (D-sub connector) U0 U1 U2

How to Order Manifold. Control unit Refer to pages to Kit/Electrical entry/cable length. kit (D-sub connector) U0 U1 U2 VQ000 ase Mounted Plug-in nit For details aout certified products conforming to international standards, visit us at www.smcworld.com. Type of connection VVQ VQ000 R port P port Port R Manifold Plug-in

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3

More information

High Pressure Coolant Valve

High Pressure Coolant Valve High Pressure Coolant Valve Series.5 MPa, 7.0 MPa Corresponding to high speed grinding and long drilling processes Coolant valve for high pressure coolant liquid (up to.5 MPa or 7.0 MPa) that is ideal

More information

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Vacuum Release Valve with Restrictor Series SJ3A6 SJ Plug-in Type Connector Connection P.86 D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Non Plug-in Type Individual

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

Fieldbus System (Gateway Decentralized Type)

Fieldbus System (Gateway Decentralized Type) Fieldbus System (Gateway Decentralized Type) * * Except the SY, VQC and S0700 valves GW Unit which supports PROFINET added. New M connector type Input Unit added. Decentralized valve installation Valves

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve CT.ES8 / ort Solenoid Valve Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M.7 to M2. 앬 Flow Characteristics Series Cover (stainless

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Series 000 Compact and lightweight: 3 mm width Compact yet provides

More information

Applicable bore size. CC-Link. EtherNet/IP. Decentralized Serial Wiring. EtherCAT I/O. Serial unit: EX600 IP67 compliant. Serial unit: EX500

Applicable bore size. CC-Link. EtherNet/IP. Decentralized Serial Wiring. EtherCAT I/O. Serial unit: EX600 IP67 compliant. Serial unit: EX500 5 Port Solenoid Valve Series C000 Metal Seal Rubber Seal Compact and large flow Type (Series) Manifold pitch (mm) C000 5 6. 0.7.7 7. 0..0 to ø Note) Flow characteristics: position single, / 5/ (/ R/R)

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

Series SY3000/5000 How to Order Manifold

Series SY3000/5000 How to Order Manifold Type N ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN Rail Mounted/Connector ox SY/ How to Order Manifold SSY SY SY Specifications Symbol Specifications With connector box (COM spec.) N With

More information

Plug Lead Unit: Flip Type

Plug Lead Unit: Flip Type Series ody orted lug Lead Unit: Flip Type For details about certified products conforming to international standards, visit us at www.smcworld.com. 0 Series Kit/Electrical entry/cable length F kit (D-sub

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

3 Port Air Operated Valve

3 Port Air Operated Valve Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation

More information

Flow characteristics Max. (1) b Standard Specifications. P Manual override.

Flow characteristics Max. (1) b Standard Specifications. P Manual override. Port Direct Operated Solenoid Valve Series 0 Metal Seal Model Number of positions (Single) (Double) ( position) JIS Symbol Model Port size Rc (Nominal size) 0-0 8 ( A) 0- ( 8A) 0-0 8 (0A) 0-0 8 ( A) 0-

More information

Series SYA3000/5000/7000

Series SYA3000/5000/7000 1 Port Air Operated Valve Series SYA000/000/7000 Body ported Base mounted Base mounted How to Order A, B port size Thread type Thread piping (Inch size) Nil Rc Symbol Port size Applicable series Symbol

More information

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Body Ported Base Mounted Series S000 S000 S000 S000 S000 S4000 S5000 Sonic conductance C [dm /s bar)] 4/ 5/(A/B R/R) Single Double.8.4

More information

Non-Contact Sensor for Workpiece Placement Verification

Non-Contact Sensor for Workpiece Placement Verification ir Catch Sensor Series 2 Non-Contact Sensor for Workpiece Placement Verification Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact

More information

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot 3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in

More information

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles ort Solenoid Valve: ase Mounted Metal Seal/Rubber Seal Series Space and capacity saving ilot valve is gathered at one side. Space saving design which does not have any protrusions. Space saving Capacity

More information

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle. Multistage Ejector 112/212 Series Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus

More information