3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

Size: px
Start display at page:

Download "3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option"

Transcription

1 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm 3 /(s bar) (Passage 3) Suitable for use in vacuum applications 101. kpa (For vacuum specifications: VT/VO317V) single valve with 6 valve functions (Universal porting type) Selective porting can provide 6 valve functions, such as N.C. valve, N.O. valve, Divider valve, Selector valve etc. V T G 0 Body type T Body ported O Manifold Valve option Nil Standard type E Continuous duty type V For vacuum Rated voltage VC, Hz 00 VC, Hz VC, Hz 4 0 VC, Hz 5 4 V 6 1 V 7 40 VC, Hz Note 1) CE-compliant: Electrical entry is applicable only for the DIN terminal. Note ) For other rated voltages, please consult with SMC. How to Order Thread type Nil F N T CE-compliant Nil Q CE-compliant CE-compliant: Electrical entry is applicable only for the DIN terminal. Port size Nil 0 Rc G NPT NPTF Without port (For manifold) 1 4 (8) Symbol () (R)3 1(P) Manifold Electrical entry G Grommet, 300 mm lead wire H Grommet, 600 mm lead wire C Conduit T Conduit terminal D DIN terminal Model VO317(-Q) CE-compliant Light/Surge voltage suppressor CE-compliant Electrical entry G H C T D Only"D" Symbol Nil Note) Note) Note) S Z S: With surge voltage suppressor Note) Refer to the figure below. Z: With light/surge voltage suppressor pplicable manifold type ccessory Common or individual exhaust O-ring (K00066, 4 pcs.) Note) Hexagon socket head screw (XT01-5C#1, pcs.) Note) It is not applied to Continuous duty type. Refer to the accessories on page Surge voltage suppressor mounting part (For G ) Surge voltage suppressor VV061 VV100 V100 S070 VQD VQD-V VK VT 1441

2 VT317 Series Flow Rate Characteristics/Weight Standard Specifications Type of actuation Fluid Operating pressure range mbient and fluid temperature Response time (1) Max. operating frequency Lubrication Mounting orientation Impact/Vibration resistance () Enclosure Electrical entry rated voltage (V) llowable voltage fluctuation pparent power (3) Power consumption (3) Light/Surge voltage suppressor (Not applicable for grommet type) C (50/60 Hz) Inrush C Holding C Direct operated type position single solenoid ir 0 to 0.9 MPa 10 to 50 C (No freezing.) 30 ms or less (at the pressure of 0.5 MPa) 10 Hz Not required (Use turbine oil Class 1 ISO VG3, if lubricated.) Non-locking push type Unrestricted 150/50 m/s Dustproof Grommet, Conduit, Conduit terminal, DIN terminal 100, 00, 110, 0, 40 4, 1 15 to +10% of rated voltage 19 V (50 Hz), 16 V (60 Hz) 11 V (50 Hz), 7 V (60 Hz) Without indicator light: 6 W, With indicator light: 6.3 W, Neon bulb, LED (Neon bulb for 100 V or more) Semi-standard Note 1) Based on dynamic performance test, JIS B 8419: 010. ( temperature: 0 C, at rated voltage, without surge suppressor) Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 1000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Note 3) t rated voltage Flow rate characteristics Valve model 1 (P ) 3 ( R) 3 (R ) 1 ( P) C [dm 3 /(s bar)] b Cv C [dm 3 /(s bar)] b Cv C [dm 3 /(s bar)] b Cv C [dm 3 /(s bar)] b Cv VT317 VT317V (Vacuum spec. type) VT317E (Continuous duty type) Note) Values for a single valve unit. It differs in the manifold case. Refer to manifold specifications on page Weight Grommet 0.9kg Valve Options Continuous duty type: VT317E Exclusive use of VT317E is recommended for continuous duty with long time loading. 1. This model is for continuous duty, not for high cycle rates. But even in low cycle rates, if energizing the valve more than once a day, please consult with SMC.. Energizing solenoid should be done at least once in 30 days. Vacuum spec. type: VT317V This vacuum model has less air leakage than the standard model under low pressure. It is recommended for vacuum application. 1. Since this valve has slight air leakage, it can not be used for vacuum holding (including positive pressure holding) in the pressure container. Specifications different from standard are as follows. Operating pressure range 101. kpa to 0.1 MPa 144 Construction De-energized Operation principles <De-energized> Spool valve w is pushed upward by the return spring e, port P is closed, and port and port R are opened. Component Parts No. 1 Description Body Spool valve Material luminum die-casted luminum, NBR Note Color: Platinum silver Energized <Energized> When an electric current is applied to the molded coil r, the armature t is attracted to the core y, and through the push rod u, it pushes down the spool valve w. Then, port P and port are connected. t this time, there will be gaps between the armature t and the core y, but the armature will be magnetically attracted to the core y.

3 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Dimensions Grommet: VT317- G Conduit: VT317- C fitting position 4 positions per Note) (Lead wire length) fitting position 4 positions per (Lead wire length) x M6 mounting hole For top mounting (M4) x M6 mounting hole For top mounting (M4) ( positioning pin) ( positioning pin) 3 x 1/4 x M6 x 1 for bottom mounting 3 x 1/4 x M6 x 1 for bottom mounting Note) There is also VT317- H (Lead wire length: 600 mm). Conduit terminal: VT317- T fitting position 4 positions per 90 DIN terminal: VT317- D x M6 mounting hole For top mounting (M4) fitting position 4 positions per 90 x M6 mounting hole For top mounting (M4) 3 x 1/4 ( positioning pin) x M6 x 1 for bottom mounting 3 x 1/4 ( positioning pin) Max. 10 DIN terminal facing upward (101.6) x M6 x 1 for bottom mounting VV061 VV100 V100 S070 VQD pplicable cable O.D. ø6 to ø1 VQD-V VK VT 1443

4 VT317 Series Manifold Specifications VT317 manifold is B mount type and available both as a common exhaust and individual exhaust model. VV Common exhaust VV VV Individual exhaust Ordering example: VV pc. (5-station manifold base) VO317-1G 4 pcs. PVT pc. (Blanking plate) How to Order Manifold VV Base type: 1/4 VT317 manifold Please indicate manifold base type, applicable manifold valve and blanking plate when ordering. Valve stations 0 stations 0 0 stations Max. 0 stations Manifold Specifications Manifold type Max. number of stations pplicable solenoid valve Exhaust port Symbol 1 3 Type Common () Individual Symbol Symbol 1 Option CE-compliant port size (Base piping) 1/4 Note 1) For more than 3 stations, supply air both sides of P port. The common exhaust type should exhaust from both of the R port. Note ) In the case of common exhaust type, R and P ports size can be Rc 3/8 by using a mounting adaptor. Note 3) Can also be applied to VVT30 series manifold. Nil Nil Q CE-compliant Without mounting bracket With mounting bracket Common exhaust type only Thread type Nil F N T Passage P R Common Common Rc G NPT NPTF Porting specifications Side 3 Common Individual Side P Base (Side) 1 4 ( 3 8 ) Base (Side) 1 4 B mount 0 stations (1) VO317 - (-Q) (3) Port location (Direction)/Port size Base (Side) 1 4 Base (Side) 1 4 R Base (Side) 1 4 ( 3 8 ) Base (Side) 1 4 ccessory for pplicable Solenoid Description O-ring Hexagon socket head screw Part no. K00066 (P10) K00098 (P10F) XT01-5C#1(M ) Qty 4 Note Standard type vacuum specifications type Continuous duty type Option Description Part no. Blanking plate (With screw, O-ring) PVT Mounting bracket assembly DXT (With screw) (For common exhaust) : Thread type (Refer to How to Order.) Flow Rate Characteristics/Weight Flow rate characteristics Valve model 1 (P ) 3 ( R) 3 (R ) 1 ( P) C [dm 3 /(s bar)] b Cv C [dm 3 /(s bar)] b Cv C [dm 3 /(s bar)] b Cv C [dm 3 /(s bar)] b Cv VO317 VO317V (Vacuum spec. type) VO317E (Continuous duty type) 1444 Weight Grommet 0.3kg

5 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Dimensions: Common Exhaust (Interchangeable with VVT30 for mounting) Without mounting bracket: VV single valve unit port location x ø7 mounting hole P port port R port (Station 1) (Station n) n x 1/4 DIN terminal facing upward x 1/4 pplicable cable O.D. ø6 to ø1 L Dimension L Stations L1 L n: Stations Formula L1 = 46 x n + 9 L = 46 x n + 14 With mounting adaptor: VV x ø7 mounting hole (Station 1) (Station n) n x 1/4 pplicable cable O.D. ø6 to ø1 DIN terminal facing upward L Dimension L Stations L1 L x 3/ n: Stations Formula L1 = 46 x n + 89 L = 46 x n VV061 VV100 V100 S070 VQD VQD-V VK VT

6 VT317 Series Dimensions: Individual Exhaust Without mounting bracket/vv x ø7 mounting hole Manual override (Station 1) (Station n) Conduit (C) Grommet (G) Conduit terminal (T) DIN terminal (D) DIN terminal facing upward (136.6) n x 1/4 pplicable cable O.D. ø6 to ø1 L Dimension Stations 3 L L L n: Stations Formula L1 = 46 x n + 9 L = 46 x n + 14 Precautions Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 3 to 9 for 3/4/5 Port Solenoid Valve Precautions. Mounting Warning 1. When mounting valves on the manifold base, the mounting orientation is decided. If it is mounted in the wrong direction, connected equipment may malfunction. Mount it by referring to how to switch over from N.C. to N.O. specifications. 1. Each valve is fixed to the manifold base with two M4 mounting screws. Tighten the screws evenly when re-mounting. Tightening torque of the mounting screw (M4): 1.4 N m. For mounting, tighten M4 or equivalent screws evenly into the mounting holes of the manifold base. Universal porting permits convertibility N.C./N.O. by a simple 180 degree rotation. Mounting conditions for N.C. and N.O. is indicated as below figure. Exhaust port type Common exhaust Individual exhaust Valve Changing from N.C. to N.O. N.C. Changing from N.C. to N.O. This product is delivered as N.C. valve. If N.O. valve is needed, remove mounting screws of the required valve and turn the valve at 180 degrees. (Make sure that there are O-rings fixed on 4 positions of the valve surface.) Then, tighten the mounting screws to fix the valve to the manifold base. N.O. 1446

7 1 3 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series How to Use DIN Terminal 1. Disassembly 1) fter loosening the screw q, then if the housing r is pulled in the direction of the screw q, the connector will be removed from the body of equipment (solenoid, etc.). ) Pull out the screw q, then remove the gasket or. 3) On the bottom part of the terminal block e, there s a cut-off part (indication of an arrow). If a small flat head screwdriver is inserted between the opening in the bottom, terminal block e will be removed from the housing r. (Refer to graph at right.) 4) Remove the cable gland t and plain washer y and rubber seal u.. Wiring 1) Pass the cable i through the cable gland t, washer y, rubber seal u, in this order and then insert them into the housing r. ) Dimensions of the cable i are as shown in the right figure. Skin the cable and crimp the crimped terminal o to the edges. 3) Remove the screw with washer from the bracket. (Loosen in the case of Y-shape type terminal.) s shown in the right figure, mount a crimped terminal o, and then again tighten the screw. Note) Tighten within the tightening torque of 0.5 N m ±15%. Note: a It is possible to wire even in the state of bare wire. In that case, Note 1) mark in the product model numbers denotes the rated voltage. Note ) mark denotes the valve option. Note 3) mark and mark are for coil part number and coil assembly with terminal the rated voltage. Example 1) In the case of PVT GB-05 Example ) In the case of PVT317-5G Note 4) In the case of CE-compliant products (-Q), coils are not shipped together. loosen the screw with washer o and place a lead wire into the bracket, and then tighten it once again. b The maximum size for the round terminal o is 1.5 mm 3.5 and for the Y terminal is 1.5 mm 4. c Cable i outside diameter: ø6 to ø1 mm Note) For the one with outside diameter ranged between ø9 to ø1 remove the inside parts of the rubber seal u before using. 3. ssembly 1) Terminal box e connected with housing r should be reinstated. (Push it down until you hear the click sound.) ) Putting rubber seal u, plain washer y, in this order into the cable introducing slit on the housing r, then further tighten the cable gland t securely. 3) By inserting gasket or between the bottom part of the terminal box e and a plug on an equipment, screw in q on top of the housing r and tighten it. Note) Tighten within the tightening torque of 0.5 N m ±0%. Changing the entry direction The cable entry direction of a connector can be changed as desired (4 directions at 90 intervals), depending on the combination of a housing r and a terminal block e. Comparison between the Product Model No. and the Part No. Product model no. VT/O317 - G(-0) VT/O317 - GS(-0) VT/O317 - H(-0) VT/O317 - HS(-0) VT/O317 - C(-0) VT/O317 - CS(-0) VT/O317 - T(-0) VT/O317 - TS(-0) VT/O317 - TZ(-0) VT/O317 - D(-0) VT/O317 - DS(-0) VT/O317 - DZ(-0) Exploded view When the rated voltage is C and if it is assembled with the coil for, response may be delayed and occur malfunction. lso, for valves, when the coil for C is assembled, it occurs malfunction. For C valves, assemble the coil for C, and for valves, assemble the coil for. Connector for DIN Terminal no. PVT GB- PVT317- G PVT GB- L06 PVT317- G-06 PVT CB- PVT317- C PVT DB- PVT DB- PVT DB- Without light/surge voltage suppressor Rated voltage (D) 100 VC 00 VC GDM 4 V For other rated voltages, please consult with SMC. With surge voltage suppressor (DS) GDM-S1 GDM-S GDM-S5 e q o r y u o Magnifying figure Self-up screw assembly with terminal part no. PVT TBT- PVT TBTS- PVT TBTZ- PVT DBT- PVT DBTS- PVT DBTZ- t Light/Surge voltage suppressor (DZ) GDM-Z1 GDM-Z GDM-Z5 i VV061 VV100 V100 S070 VQD VQD-V VK VT 1447

8 VT317 Series Specific Product Precautions Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 3 to 9 for 3/4/5 Port Solenoid Valve Precautions. 1. bleed port for the main valve is located at the bottom of the solenoid valve. Since blocking it causes malfunction, do not block it. Ordinarily, when the solenoid valve is mounted on a metal surface, it can breathe through the breather hole, via the breather groove. However, in particular, if the surface to be mounted is made of the rubber, the rubber could deform and block the hole.. Make sure that dust and/or other foreign materials should not enter the valve from the unused port (e.g. exhaust port). lso, since there is a bleed port for the armature in the manual override, do not allow accumulation of dust and/or other foreign materials to block bleed port. Manual override Change of Electrical Entry ngle 1. The VT317 series can change electrical entry angle. (4 positions). How to change: Loosen the nut (1), remove the coil () from the body assembly (3), place the positioning pin (4) at the required place, put back the coil () to its place, and tighten sufficiently with lock nut (1). Light/Surge Voltage Suppressor Grommet (G) Conduit (C) (1) () (4) (3) Conduit terminal (T) DIN terminal (D) C Surge voltage suppressor (S) Red + ( ) ( ) Black Diode Bleed air passage Bleed port of main valve Neon bulb C Bottom of the solenoid valve How to Calculate the Flow Rate For obtaining the flow rate, refer to front matter. Light/Surge voltage suppressor (Z) None 48 V or less Protection circuit for light/surge voltage suppressor is not the polarity type. 100 V Neon bulb Lead Wire Color (Grommet) Voltage 100 VC 00 VC Other Color Blue Red Red (+), Black ( ) Gray Electrical Connection DIN terminal is connected inside as in the figure below. Connect to the corresponding power supply Ground

9 3 Port Solenoid Valve Direct Operated Poppet Type VT35 Series Rubber Seal [Option] Note) CE-compliant: Electorical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118 x 53 (Grommet) C: 0.61 dm 3 /(s bar) {Rc 3/8 (Passage 3)} single valve with 6 valve functions (Universal porting type) Six valve functions can be attained by selecting the piping ports. (Enabling the N.C. valve, N.O. valve, divider valve, selector valve, etc. to be used as desired.) Suitable for use in vacuum applications 101. kpa (For vacuum specifications type: VT/VO35V) VT35- T Symbol (R)3 () VT35- C 1(P) VT35- D VT35- G VT35 Manifold Model VO35-00 (-Q) Specifications Type of actuation Fluid Operating pressure range mbient and fluid temperature Max. operating frequency Response time (1) Lubrication Impact/Vibration resistance () Enclosure 0 1 G For manifold: Enter VO. Nil Non-locking type Valve option M Locking type (Tool required) Nil Standard Surge voltage suppressor CE-compliant V For vacuum Nil None Port size With surge voltage suppressor S 00 Without connection port (For manifold) Direct operated type position single solenoid ir 0 to 1.0 MPa 5 to 50 C 5 Hz 30 ms or less (at the pressure of 0.5 MPa) Not required (Use turbine oil Class 1 ISO VG3, if lubricated.) Non-locking push type 150/50 m/s Dustproof Note 1) Based on dynamic performance test, JIS B 8419: 010. ( temperature: 0 C, at rated voltage, without surge suppressor) Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 1000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Solenoid Specifications Electrical entry rated voltage llowable voltage fluctuation pparent power (3) Power consumption (3) Note 3) t rated voltage Rated voltage 100 VC, 50/60 Hz 00 VC, 50/60 Hz 110 VC, 50/60 Hz 0 VC, 50/60 Hz 4 V 1 V 40 VC, 50/60 Hz Note1) CE-compliant: Electorical entry is applicable only for the DIN terminal. Note) For other rated voltages, please consult with SMC. pplicable manifold B mount common exhaust type C How to Order Electrical entry CE-compliant G C D T Grommet, Lead wire length 00 mm Conduit DIN terminal Conduit terminal TL Terminal with indicator light DL DIN terminal with indicator light For the coil rated voltage (Semi-Standard ), please contact SMC. Inrush Holding C: Can be attached to Grommet, Conduit, Conduit terminal. : Can be attached to Grommet, Conduit, Conduit terminal. 50 Hz 60 Hz 50 Hz 60 Hz Thread type Nil F N T ccessory Gasket (DXT ) Bolts (DXT , pcs.) Grommet, Conduit, DIN terminal, Conduit terminal 100, 00 VC, 50/60 Hz, 4 V 15 to +10% of rated voltage 75 V 60 V 7 V 17 V 1 W Rc G NPT NPTF CE-compliant Nil Q CE-compliant CE-compliant: Electorical entry is applicable only for the DIN terminal VV061 VV100 V100 S070 VQD VQD-V VK VT

10 VT35 Series Flow Rate Characteristics/Weight Valve model Flow rate characteristics Port size 1 (P ) 3 ( R) 3 (R ) 1 ( P) C [dm 3 /(s bar)] b Cv C [dm 3 /(s bar)] b Cv C [dm 3 /(s bar)] b Cv C [dm 3 /(s bar)] b Cv 1/ VT35 VT35V (Vacuum spec. type) VT35 VT35V (Vacuum spec. type) 3/ Note) Values for a single valve unit. It differs in the manifold case. Refer to manifold specifications on page 145. Weight Grommet 0.55 kg (For C) 0.60 kg (For ) Valve Option 1. For vacuum Pressure range 101. kpa to 0.1 MPa This vacuum model has less air leakage than the standard model under low pressure. It is recommended for vacuum application. 1) Since this valve has slight air leakage, it can not be used for holding vacuum (including positive pressure holding) in the pressure container.. With surge voltage suppressor, with indicator light Surge Voltage Suppressor C Grommet Red (+) (GS) Conduit (CS) Black ( ) Conduit terminal (TS) Circuit for Indicator Light C DIN terminal Neon with indicator light bulb (DL) Conduit terminal Neon with indicator light bulb (TL) Grommet type Surge voltage suppressor Diode Construction No. 1 3 De-energized o Retainer Operation principle <De-energized> The spool e is pushed upward by the force of the spring r and the air passage between port x and port c is opened and port z is blocked. ir flow direction: z Block, x c Component Parts Description Body Cover Spool valve Material luminum die-casted luminum die-casted luminum, NBR u Plunger w Cover y i Over travel assembly q Body e Spool valve t O-ring r Spool spring Note Platinum silver Platinum silver Energized <Energized> When the coil y is energized the plunger u is pulled down depressing the spool e via the overtravel assembly i and the air passage between port z and port x is opened and port c is blocked. ir flow direction: z x, c Block 3. with lock 1) Using a screwdriver, push the manual override button that is located in the head portion of the solenoid valve in order to directly push the spool valve downward, thus causing the valve to switch. ) With the button remaining pushed down, turn it approximately 90 clockwise or counterclockwise to maintain the manual override locked state. 3) To revert to the original state, keep the button pushed down and turn it approximately 90 clockwise. 1450

11 3 Port Solenoid Valve Direct Operated Poppet Type VT35 Series Dimensions Grommet (G) Conduit (C) x mounting groove Lead wire length 180 x mounting groove 00 3 x Rc 1/4, 3/8 Width across flats 3 x Rc 1/4, 3/8 Width across flats 3 x ø4.5 mounting hole DIN terminal (D) Connector pplicable cable O.D. ø6 to ø1 Conduit terminal (T) x mounting groove x mounting groove 3 x Rc 1/4, 3/8 Width across flats 3 x Rc 1/4, 3/8 Width across flats With locking manual override 19.3 (With locking type manual override) Conduit terminal with indicator light (TL) x mounting groove Light VV061 VV100 V100 S070 VQD VQD-V VK VT 3 x Rc 1/4, 3/8 Width across flats 1451

12 VT35 Series Manifold Specifications The VT35 series Manifold Model has a B mount type with common exhaust. Common exhaust VVT Porting specifications Symbol 0 1 P Side Side Side Bottom Valve stations 0 stations 17 How to Order Manifold 1 Manifold Specifications R Side Side 17 stations Port size Symbol Port size Exhaust port type 1 Common exhaust Manifold type Max. number of stations pplicable solenoid valve Port location/port size Exhaust port type P R Base Base Base Common 1 4, , , 3 8 Option Blanking plate (With gasket, screw) CE-compliant Nil Q CE-compliant Thread type Instruct by specifying the valves and blanking plate to be mounted on the manifold along with the manifold base model no. <Example> VVT pc. VO35-001G 4 pcs. DXT pc. B mount 17 stations Note) VO35-00 (-Q) Port direction P Side Side/Bottom Note) If there are more than 4 stations, supply air from both P ports and exhaust from both R ports. Nil F N T Rc G NPT NPTF R Side DXT083-1 ccessory for pplicable Description Part no. Qty. Manifold gasket DXT pc. Hexagon socket head screw DXT pcs. Flow Rate Characteristics/Weight Valve model VO35 VO35V (Vacuum spec. type) Flow rate characteristics 1 (P ) 3 ( R) 3 (R ) 1 ( P) C [dm 3 /(s bar)] b Cv C [dm 3 /(s bar)] b Cv C [dm 3 /(s bar)] b Cv C [dm 3 /(s bar)] b Cv Weight Grommet 0.58 kg (For C) 0.63 kg (For ) Warning When mounting valves on the manifold base, the mounting orientation is decided. If it is mounted in the wrong direction, connected equipment may malfunction. Mount it by referring to external dimensions on page Besides, the external dimensions are showing the case of N.C. specifications. Precautions Changing from N.C. to N.O. The valves are assembled as N.C. valves at the time of shipment. By removing the two retaining screws from the desired valves, and rotating each valve body 180 and reassembling it on the manifold base, it is possible to reassemble an N.C. valve as an N.O. valve. (When doing so, make sure that a gasket is attached to the mounting surface of the valve.) Properly tighten the screws. The tightening torque of the retaining screws is 3 N m. 145

13 3 Port Solenoid Valve Direct Operated Poppet Type VT35 Series Dimensions Common exhaust Pitch x ø9 mounting hole (Station 1) (Station n) 4 x Rc 1/4, 3/8 Max. n x Rc 1/4, 3/8 Bottom ported Pitch Conduit DIN terminal (T) Grommet (G) terminal (D) Conduit (C) For bottom ported single valve unit port location Blanking plate Port (1), Port () Port (3) Pitch n x Rc 1/4, 3/8 Symbol n 3 4 L1 L Formula: L1 = 46n + 39, L = 46n n: Stations VV061 VV100 V100 S070 VQD VQD-V VK VT 1453

14 1 3 VT35 Series Specific Product Precautions Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 3 to 9 for 3/4/5 Port Solenoid Valve Precautions. 1. The bottom of the solenoid valve has a breather hole for the main valve. Take proper measures to prevent this hole from being blocked as this will lead to a malfunction. Ordinarily, when the solenoid valve is mounted on a metal surface, it can breathe through the breather hole, via the breather groove. However, in particular, if the surface to be mounted is made of the rubber, the rubber could deform and block the hole. Bleed groove Grommet Bottom of the solenoid valve Bleed port on main valve. Make sure that dust and/or other foreign materials do not enter the valve from the unused port (e.g. exhaust port). The grommet portion contains a breather hole for the core. Take proper measures to prevent dust or foreign matter from accumulating in this area. How to Calculate the Flow Rate For obtaining the flow rate, refer to front matter. 1. Disassembly 1) fter loosening the screw q, then if the housing r is pulled in the direction of the screw q, the connector will be removed from the body of equipment (solenoid, etc.). ) Pull the screw q, and then remove gasket a or b. 3) On the bottom part of the terminal block e, there s a cut-off part (indication of an arrow) 3a. If a small flat head screwdriver is inserted between the opening in the bottom, terminal block e will be removed from the housing r. (Refer to the figure below.) 4) Remove the cable gland t and plain washer y and rubber seal u.. Wiring 1) Pass the cable i through the cable gland t, washer y, rubber seal u in this order, and then insert them into the housing r. ) Dimensions of the cable i are the figure as below. Skin the cable and crimp the crimped terminal o to the edges. 3) Remove the screw with washer q 3e from the bracket 3e. (Loosen in the case of Y shape type terminal.) s shown in the below figure, mount a crimped terminal o, and then again tighten the screw 3e. Note) Tighten within the tightening torque of 0.5 N m ±15%. Note: a It is possible to wire even in the state of bare wire. In that case, loosen the screw with washer 3e and place a lead wire into the bracket 3d, and then tighten it once again. b The maximum size for the round terminal o is 1.5 mm 3.5 and for the Y terminal is 1.5 mm 4. c Cable i outside diameter: ø6 to ø1 mm Note) For the one with the outside diameter ranged between ø9 to ø1 remove the inside parts of the rubber seal u before using. How to Use DIN Terminal 3. ssembly 1) Terminal box e connected with housing r should be reinstated. (Push it down until you hear the click sound.) ) Putting rubber seal u, plain washer y, in this order into the cable introducing slit on the housing r, then further tighten the cable gland t securely. 3) By inserting gasket a or b between the bottom part of the terminal box e and a plug on an equipment, screw in q on top of the housing r and tighten it. Note) Tighten within the tightening torque of 0.5 N m ±0%. Note: The orientation of a connector can be changed arbitrarily, depending on the combination of a housing r and a terminal box e. Exploded view (1) (4) (3d) (3d) (3c) (3) (3a) (3e) (b) (9) (a) (7) (6) (3e) (3e) (9) Magnifying figure Self-up screw (5) (8) Connector for DIN Terminal Description DIN connector Part no. GDMC 1454

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum 3 Port Direct Operated Poppet Rubber Seal Series 307 Large Flow Capacity, yet Compact Size. Dimensions (W X H X D) 30 X 54.5 X 33 307 Nl/min 206.02 or more, 1/4 Low Power Consumption /VO307 4.8W DC/Standard

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes

More information

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing

More information

1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption

1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption Port Solenoid Valve Direct Operated Poppet Type Power consumption Vacuum applications New [Option] RoHS 4 Standard wtype (Existing product: 4.8 W) 0. kpa Energy-saving type.8 w (Existing product: W) A

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot 3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

3 Port Solenoid Valve

3 Port Solenoid Valve 3 ort Solenoid Valve Series VKF300 ubber Seal Direct Operated oppet Type Compact yet provides a large flow capacity Body width 8 mm vailable in vacuum applications ( 0. ka) Can be used in vacuum/release

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

Indicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A

Indicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A 1 3 Port Air Operated Valve Series VTA301 JIS Symbol VTA 301 Indicate VO for manifold. Port size Specifications How to Order Without connection port (For manifold) 01 1/8 02 1/4 Option Fluid Air Operating

More information

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000) 5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Series 000 Compact and lightweight: 3 mm width Compact yet provides

More information

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series

More information

3 Port Air Operated Valve VTA. Indicate VO for manifold. Port size. Nil 02 1/4. Specifications Fluid. Option Description Bracket (With screw)

3 Port Air Operated Valve VTA. Indicate VO for manifold. Port size. Nil 02 1/4. Specifications Fluid. Option Description Bracket (With screw) Series VTA301 How to Order VTA 301 Indicate VO for manifold. Port size Without connection port (For manifold) 01 1/8 02 1/4 F N T Option B Rc G NPT NPTF Without bracket Foot bracket JIS Symbol Specifications

More information

Exclusively for air pressure system and air-hydro circuit control

Exclusively for air pressure system and air-hydro circuit control Process Valve Series Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external

More information

Flow characteristics Max. (1) b Standard Specifications. P Manual override.

Flow characteristics Max. (1) b Standard Specifications. P Manual override. Port Direct Operated Solenoid Valve Series 0 Metal Seal Model Number of positions (Single) (Double) ( position) JIS Symbol Model Port size Rc (Nominal size) 0-0 8 ( A) 0- ( 8A) 0-0 8 (0A) 0-0 8 ( A) 0-

More information

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control Process Valve Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external pilot

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

Process Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control Process Valve: Port Valve For Compressed ir and ir-hydro Circuit Control Series VN Style VN -6 VN -8 8 VN - 3 8 VN - 5 VN -5 VN3-0 3 0 Note) This product cannot be used for water application. JIS Symbol

More information

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

Coolant Valve. Air Operated/External Pilot Solenoid

Coolant Valve. Air Operated/External Pilot Solenoid Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) lange type (3 to ) Low water hammer or details, refer to page

More information

High Pressure Coolant Valve

High Pressure Coolant Valve High Pressure Coolant Valve Series.5 MPa, 7.0 MPa Corresponding to high speed grinding and long drilling processes Coolant valve for high pressure coolant liquid (up to.5 MPa or 7.0 MPa) that is ideal

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR2 JIS Symbol type

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry

More information

5 Port Air Operated Valve

5 Port Air Operated Valve Port ir Operated Valve Series VF000/000/000 RoHS 22- Series VF000/000/000 Model Selection by Operating Conditions q ir Operated Valve: Single Unit Series Sonic conductance C[dm /(s bar)] Type of actuation

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M. V3 Cover

More information

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Vacuum / Release Unit Series VQD1000-V Rubber Seal Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area [Option] Smooth detachment of a work piece without

More information

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) type (3 to ) Low water hammer or details, refer to page 07. Large

More information

0.35 W (Without light)

0.35 W (Without light) Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:

More information

Series SV1000/2000/3000/4000

Series SV1000/2000/3000/4000 Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double

More information

Vacuum / Release Unit

Vacuum / Release Unit Rubber Seal Vacuum / Release Unit Series VQD1000-V Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area Smooth detachment of a work piece without over-blow

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

Coolant Valve. VNC Series. Cylinder actuation by pilot air

Coolant Valve. VNC Series. Cylinder actuation by pilot air oolant VN Series ir Operated/xternal Pilot Solenoid [Option] ylinder actuation by pilot air Wide selection of port and variations Threaded type (6 to ) lange type (3 to 80) Low water hammer or details,

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

3 Port Air Operated Valve

3 Port Air Operated Valve Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position

More information

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal

More information

Rubber Seal VP300/500/700

Rubber Seal VP300/500/700 Port Pilot Operated Poppet Rubber Seal 00/500/700 High flow capacity Cv1.0 (00), Cv. (500), Cv.0 (700) Low power consumption: 1.8W(DC) Possible to use as either selector valve or divider valve Changeable

More information

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Body Ported Base Mounted Series S000 S000 S000 S000 S000 S4000 S5000 Sonic conductance C [dm /s bar)] 4/ 5/(A/B R/R) Single Double.8.4

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot ubber seal ort ilot Solenoid Valve Series SYJ00 Specifications efer to www.smcworld.com for details of products compatible with overseas standards. Body ported Base mounted Fluid Operating pressure range

More information

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC)

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC) Port Solenoid Valve/Direct Poppet Rubber seal Series VK3000 Nl/min 147 Compact/Width 18 X Length 8 (mm) Low power consumption 4W DC (Standard) 2W DC (Energy saver) Standard copper free specification All

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3

More information

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S. High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure of 0.5MPa, subject to clean, dry air) 4 Port Direct

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model 2 position 3 position

More information

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),

More information

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series VZS Series Variations Plug-in Type Base Mounted Type (With sub-plate) Non Plug-in Type Base Mounted Type (With sub-plate) Series Sonic conductance

More information

Series VQZ1000/2000/3000 Single Unit

Series VQZ1000/2000/3000 Single Unit +- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

1 1/4 (32A) to 2 (50A) added.

1 1/4 (32A) to 2 (50A) added. Coolant Valve 0.5 MPa.0 MPa.6 MPa RoHS /4 (3) to (50) added. Flow rate Cv (For 0.5 MPa specification) 3 4 5 0 0 30 Cv (kv) 40 5 million cycles or more Port size 70 6.5 (5.6) 3/8 (0), / (5).8 (0.) 3/4 (0)

More information

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type. Series -S00 ompact Direct Operated Port Solenoid Valve ontrol Valves ase mounted ody ported lean Series lean Series V S R oil voltage 24 VD VD VD VD VD Power consumption Pressure specification Flow rate

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted

More information

Series SYJ300/500/700

Series SYJ300/500/700 ort Solenoid Valve ubber Seal Series SYJ00/00/00 Low power consumption: 0.W (Without light) (Current draw: 1m at 4V DC) Completely interchangeable ilot exhaust with the previous series VJ00/00/00 and VZ00/00.

More information

3 Port 3 Position Valve

3 Port 3 Position Valve Port Position Valve Pilot Solenoid ir Operated ohs Intermediate stopping of cylinders * up to ø15 is possible. Pilot solenoid Manifold ir operated * For VEX 4, 00 mm/s, horizontal movement Power consumption:

More information

Series SYA3000/5000/7000

Series SYA3000/5000/7000 Port Air Operated Valve Series SYA000/000/7000 How to Order A, B port size Thread type Thread piping (Inch size) Nil Rc Symbol Port size Applicable series Symbol Port size Applicable series F G M SYA000

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high

More information

Non-Contact Sensor for Workpiece Placement Verification

Non-Contact Sensor for Workpiece Placement Verification ir Catch Sensor Series 2 Non-Contact Sensor for Workpiece Placement Verification Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact

More information

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm 4 Port Direct Operated Poppet Solenoid Valve Series D1000 High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure

More information

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04 Three functions (pressure regulator, switching valve, and speed controller) are provided by a single valve. The conventional valve combination circuit has been condensed into a single valve. A large capacity

More information

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is. Port Solenoid Valve Series VQ 00 Unprecedented high speed, stable response, and extra-long service life. ON:.ms, OFF: ms, Dispension accuracy ±ms (With indicator light and surge voltage suppressor; supply

More information

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold Port Solenoid Valve VV00 Series Highly Integrated Unit Manifold po ted - pera irect-o d station es on rt valv ally ividu Ind wired n be ve ca val d. adde ector Con-inn connection) lug (For p ø connection

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series

More information

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Soft Start-up Valve. AV2000/3000/4000/5000 Series Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off

More information

Series SYA3000/5000/7000

Series SYA3000/5000/7000 Port Air Operated Valve Series SYA000/000/7000 How to Order A, B port size Thread type Thread piping (Inch size) Nil Rc Symbol Port size Applicable series Symbol Port size Applicable series F G M SYA000

More information

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector

More information

Series SYA3000/5000/7000

Series SYA3000/5000/7000 Port Air Operated Valve Series SYA000/000/7000 How to Order A, B port size Thread type Thread piping (Inch size) - Rc Symbol Port size Applicable series Symbol Port size Applicable series F G SYA000 N

More information

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A) ort Solenoid Valve ubber Seal Series SY00 Low power consumption: 0.W (Standard, Without light) (Current draw: m at V DC) Large flow capacity style:0.7w (Current draw: m at V DC) Body width: 0mm 7.8 Nl/min

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Rubber Seal Port Solenoid Valve Series Manifold Single Unit ase Mounted Manifold VV01 V100 ar base P.18 ody Ported P.10 ase Mounted P.10 VQD VKF VK VT VS Separable base ody Ported Manifold P.1 Stacking

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and

More information

Series SYA3000/5000/7000

Series SYA3000/5000/7000 1 Port Air Operated Valve Series SYA000/000/7000 Body ported Base mounted Base mounted How to Order A, B port size Thread type Thread piping (Inch size) Nil Rc Symbol Port size Applicable series Symbol

More information

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control Process Series Port For Compressed Air and Air-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Cylinder actuation by external air he balance poppet

More information

3 Port Air Operated Valve. SYJA300 Series. How to Order. Nil Without sub-plate. Type of actuation. Normally closed Normally open

3 Port Air Operated Valve. SYJA300 Series. How to Order. Nil Without sub-plate. Type of actuation. Normally closed Normally open 3 ort ir Operated Valve SYJ300 Series How to Order SYJ3 M3 Bracket Nil Without bracket F With bracket *The bracket is not mounted. *The bracket cannot be retrofitted later. SYJ3 Type of actuation Normally

More information

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating / ort Solenoid Valve ubber Seal Series SYJ000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Specifications JIS Symbol port port (manifold) position

More information

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types Speed 2 Port Valve Series RoHS speed speed speed response response response 5 ms 9mm Width ±0.05 ms ±0.05 ms type VCH : : 5 ms * The response time is measured based on SMC test conditions. (Not guaranteed

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications Series -SQ00 Port Solenoid Valve Plug-in Unit [Option] How to Order Manifold Electrical entry F kit D-sub connector kit P kit SSQ 08 FD Kit type Flat ribbon cable connector kit J kit Flat ribbon cable

More information

5 Port Solenoid Valve Plug Lead Type

5 Port Solenoid Valve Plug Lead Type 5 Port Solenoid alve Plug Lead Type Series Body Ported Flow rate characteristics For single/double solenoid C [dm 3 /(s bar)]: 0.6 Single Unit alve width: 7.4 mm Possible to drive cylinders: Up to ø32

More information

1 1/4 (32A) to 2 (50A) added.

1 1/4 (32A) to 2 (50A) added. Coolant Valve 0.5 MPa.0 MPa.6 MPa /4 (3) to (50) added. RoHS IP65 compliant For pilot valve V6 Flow rate Variations New Series SC SC3 SC4 SC5 Cv (kv) 5 0 0 30 40 70 6.5 (5.6) Cv (For 0.5 MPa specification).8

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series 1 Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000

More information

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC Base Mounted Series VQZ00/00/00 VQZ00/00 / How to Order Valve Made to Order (For details, refer to page 9 and 4.) VQZ 5 5 M Series VQZ00 body width 5 mm VQZ00 body width 8 mm Type of actuation 4 N.C. N.O.

More information

VQ1000. How to Order Manifold. Kit type

VQ1000. How to Order Manifold. Kit type - - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold

More information

How to Order Manifold. Kit type L8 B4 B6 B8 LM

How to Order Manifold. Kit type L8 B4 B6 B8 LM 0 Stations station VVQ Series VQ000 The maximum and minimum number of are varied depending on. (Refer to the table below.) Series VQ000 ase Mounted Plug-in Unit Manifold Plug-in unit 08 C Cylinder port

More information