Series PCW. PC Wiring System

Size: px
Start display at page:

Download "Series PCW. PC Wiring System"

Transcription

1 CT.ES0-0 PC Wiring System Series PCW The PC wiring system is a revolutionary new system that simplifies wiring between a PLC and all types of connected equipment.

2 revolutionary new wiring system... 4VDC Power supply Compatible PLC Manufacturers OMRON Corporation Mitsubishi Electric Corporation Fuji Electric Co., Ltd. Hitachi Ltd. Toshiba Corporation Yasukawa Electric Corporation SHRP Corporation Yokogawa Electric Corporation Matsushita Electric Works Keyence Corporation Koyo Electronics Industries Co., Ltd. Input 3 points Output 3 points Output 3 points Output 64 points 6 points 6 points ranch unit PLC direct connected type P. P. Connection cable with connector 3 points With 3 points separated 3 points With 3 points unseparated P. 3 Input ranch unit DIN rail mount type Output 8 point output unit (terminal block type) DIN rail mount type HI P. 3 Connection cable with connector P. 6 6 point input unit DIN rail mount type 6 points With 6 points separated With 6 points unseparated 6 points 6 points P. 6 6 point input unit ox mount type 6 point output unit DIN rail mount type P. 6 3 point output unit DIN rail mount type 6 points 3 points 3 point reduced common type also available. P. 5 Features

3 The PC wiring system simplifies wiring between a PL P. 4 Check unit PC Wiring System Series PCW 6 points P. 8 P. Connection cable with connector P. Connection cable with connector LO 3 points 8 points P. 4 6 points 6 points P. 3 Connection cable with connector Features

4 C and all types of connected equipment. Commonality achieved with branch unit The branch unit separates each PLC manufacturer's 3 point I/O into a 6 point common pin layout. Conversion to a common pin layout makes it possible to connect the pin layout to SMC manifold solenoid valves and other manufacturers' relay equipment without even thinking about it. Power can be supplied to the PLC's I/O unit. Compatible branch units are available for each PLC manufacturer's I/O. Simple parallel type Unlike serial transmission, there is no need to worry about transmission delay time. Visually and sensually easy to understand, maintenance is easy for start-up, debugging and trouble shooting. Improved wiring efficiency and ease of handling Reduced wiring equivalent to a serial transmission system can be attained with a special cable. The single block pressure connection system using a connector allows standardization of wiring work, prevents miswiring and greatly improves work efficiency. Fujitsu Ltd. FCN connector specifications also available. Standard specifications Fujitsu Ltd. FCN connector specifications Consult SMC regarding compatibility. Connection cable Space saving P.,, 3 The special cable with power supply line consists of a flat cable and power supply lines enclosed in a single sheath, making the conventional separate wiring of the power supply line unnecessary. Maximum wiring length 49m lso available without the power supply lines specification. General purpose terminal block unit (40P connector + 40 pin terminal block) In the case of a general purpose terminal block, common and power supply terminal blocks are not supplied as shown below, making it necessary to purchase them separately. Labor is also required for assembly. PC wiring system terminal block unit (40P connector + 64 pin terminal block + dded value) In the case of the PC wiring system terminal block unit, it is only necessary to purchase one piece and nothing else is required. (It is also compact, and the PLC manufacturer's address is stated directly on the label.) Features 3

5 PC Wiring System pplication Examples Example Connected to manifold solenoid valves Reduces wiring labor Prevents miswiring Commercially available relay terminals, etc., can also be connected Manifold solenoid valves (6 point output) Manifold solenoid valves (6 point output) ranch unit (3 point output 6 point output x ) PLC (3 point output) Example With input from a sensor switch, etc. Reduces wiring labor Prevents miswiring Requires fewer I/O points Input unit (8 point input) Cascade connection Input unit (8 point input) Input unit (6 point input) ranch unit (3 point input 6 point input x ) PLC (3 point input) Features 4

6 PC Wiring System Series PCW Common Specifications Rated voltage Power supply line Rated current Communication line Insulation resistance Withstand voltage Impact resistance Terminal block specifications Screw tightening torque Wire stripping length (recommended) Connecting wire size Power terminal (Phillips screw driver/flat head screw driver) I/O terminal (Phillips screw driver Flat head screw driver) Power terminal I/O terminal Power terminal I/O terminal 4VDC 0.3 5MΩ or more at 00VDC 0.5kV 500m/s² 0.4 to 0.6Nm/0.4 to 0.7Nm 0.5 to 0.6Nm/0.5 to 0.7Nm 7mm WG6 to 4 (0.3 to.5mm²) WG6 to (0.3 to 4mm²) Cable Specifications PVC sheath Power lines WG0 (0, 40 cores) rown lue Flat cable WG8 Flat cable Power lines Sheath O.D. With power lines Without power lines 0 cores 40 cores 0 cores 34 cores 40 cores WG8 (7 wires/0.7mm) WG0 ( wires/0.8mm) 0.3mm.0mm 8.7mm.8mm 3.0mm

7 Series PCW ranch Unit: PLC Direct Connected Type PLC connection PLC Specifications Weight mbient temperature Dimensions 5g 5 to 55 C Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page. Can be directly mounted on PLC N CN DN CN D/ (5.) Compatible PLC's and Models PLC manufacturer OMRON Corporation I/O points 3 64 Input Output Compatible model Model Compatible model Model C00H-ID6 C00H-ID8 C500-ID9 C00H-ID7 C00H-ID9 PCW C00H-OD8 C500-OD3 C00H-OD9 PCW Mitsubishi Electric Corporation Yokogawa Electric Corp SX4 X4 SX4 Note ) F3XD3-3N F3XD64-3N Note 3) PCW PCW SY4 Y4 Note ) SY4 F3YD3- F3YD64- Note 4) PCW PCW Two pieces are required for 64 points of input/output. Note ) Combine one piece each of PCW and PCW (the PLC connection side connectors are reversed). Note ) Combine one piece each of PCW and PCW (the PLC connection side connectors are reversed). Note 3) Combine one piece each of PCW and PCW (the PLC connection side connectors are reversed). Note 4) Combine one piece each of PCW and PCW (the PLC connection side connectors are reversed). Caution When removing a cable with connector, a PCW-04T puller is required.

8 C C Series PCW ranch Unit: DIN Rail Mount Type PLC connection PLC Connected to PLC via connection cable. Specifications Weight 80g mbient temperature 5 to 80 C Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page. Dimensions IN OUT RS CNO ID!/ CN CN (3.6) Compatible PLC's and Models Refer to pages and 3 for the junction cable part number. PLC manufacturer OMRON Corporation I/O points 3 64 Input Output Compatible model Model Compatible model Model C00H-ID6 C00H-ID8 CQM-ID3 C500-ID9 C00H-ID7 C00H-ID9 PCW C00H-OD8 CQM-OD3 C500-OD3 C00H-OD9 PCW Mitsubishi Electric Corporation Fuji Electric Co., Ltd. Hitachi, Ltd. Toshiba Corp. Yasukawa Electric SHRP Corporation Yokogawa Electric Corp. Matsushita Electric Works Koyo Electronics Industries Co., Ltd. Keyence Corp SX4 J35TC-3D X4 SX4 FTU5 NS-X64-I XDC4DH DI335 DI-64 JMSC-605 JW-34NC JW-34N JW-64NC F3XD3-3N F3XD64-3N FP3307 FP3308 FP33068 U-09N Note ) KZ-C3X Two pieces are required for 64 points of input/output. Note ) The mounted connector has 34 pins. SY4 J35TC-3T PCW Y4 SY4 FTU PCW NS-Y64-TI PCW YTR4DH PCW PCW PCW PCW PCW PCW PCW DO335 DO-64 JMSC-604 JW-3SC JW-3S JW-6SC F3YD3- F3YD64- FP33487 U-9T Note ) KZ-C3T PCW PCW-9930 PCW PCW PCW PCW PCW PCW PCW-9930 PCW-99340

9 0 Series PCW 3 Point Input/Output Unit PLC connection PLC Specifications Weight mbient temperature Dimensions 0g 5 to 55 C Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page. Connected to PLC via connection cable (3.6) RS X/40- CH CH IN OUT (3.7) C D E F C D E F Refer to page for the junction cable part number. Compatible PLC's and Models PLC manufacturer OMRON Corporation I/O points 3 64 Input Output Compatible model Model Compatible model Model C00H-ID6 C00H-ID8 CQM-ID3 C500-ID9 C00H-ID7 C00H-ID9 PCW C00H-OD8 CQM-OD3 C500-OD3 C00H-OD9 PCW Mitsubishi Electric Corporation Fuji Electric Co., Ltd. Hitachi, Ltd. Toshiba Corp. Yasukawa Electric SHRP Corporation Yokogawa Electric Corp. Matsushita Electric Works Koyo Electronics Industries Co., Ltd. Keyence Corp SX4 J35TC-3D X4 SX4 FTU5 NS-X64-I XDC4DH DI335 DI-64 JMSC-605 JW-34NC JW-34N JW-64NC F3XD3-3N F3XD64-3N FP3307 FP3308 FP33068 U-09N Note ) KZ-C3X Two pieces are required for 64 points of input/output. Note ) The mounted connector has 34 pins. PCW PCW PCW PCW PCW-9930 PCW PCW PCW PCW-9930 PCW-9936 SY4 J35TC-3T Y4 SY4 FTU NS-Y64-TI YTR4DH DO335 DO-64 JMSC-604 JW-3SC JW-3S JW-6SC F3YD3- F3YD64- FP33487 U-9T Note ) KZ-C3T PCW PCW PCW PCW PCW-9930 PCW PCW PCW PCW PCW

10 Series PCW 3 Point Output Reduced Common Unit PLC connection PLC Specifications Weight mbient temperature Dimensions 30g 5 to 55 C Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page. Connected to PLC via connection cable (3.6) OUT CH RS OD/040LP + 4. CH 3 (3.7) Refer to page for the junction cable part number. Compatible PLC's and Models PLC manufacturer Output points Compatible model Model OMRON Corporation 3 64 C00H-OD8 CQM-OD3 C500-OD3 C00H-OD9 PCW Mitsubishi Electric Corporation Fuji Electric Co., Ltd. Toshiba Corporation Yokogawa Electric Corp. Keyence Corp SY4 J35TC-3T Y4 SY4 FTU NS-Y64-T Two pieces are required for 64 points of output. Note ) The mounted connector has 34 pins. DO335 DO-64 F3YD3- F3YD64- Note ) KZ-C3T PCW PCW-9934 PCW-993 PCW-9933 PCW

11 + C C 0/8- Series PCW 6 Point Input/Output Unit Terminal lock: DIN Rail Mount Type Models Input Output Dimensions PCW PCW Specifications Weight 5g mbient temperature 5 to 80 C Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page RS- F6/D- CH CN IN OUT (3.7) C D E F Terminal lock: ox Mount Type Models Specifications Input Output Dimensions PCW PCW Weight mbient temperature 480g 5 to 80 C Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page M3 x 0.5 -ø5 machined for bar ring Mounting hole CN CN CH (3.7) 59 IN OUT 8 58 () C D E F (3) v ø ø

12 Series PCW 6 Point Input/Output Unit Connector: DIN Rail Mount Type Model Specifications Input Output Dimensions PCW-9933 PCW Weight mbient temperature 70g 5 to 80 C Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page (3.6) 0.5 Caution Connectors are manufactured by Molex Japan Co., Ltd., and are not handled by SMC. Please order them separately. Housing: Crimp pin: CH CN 0 CN CN 8 + CN CN PS CN PC CN 3 CN 4 CN 5 CN 6 RS CN 9 CN CN 8 CN C CN D CN E 3 IN F6/DT CN S CN F Point Output Reduced Common Unit Model Terminal lock: DIN Rail Mount V Type Specifications Output PCW Weight 80g mbient temperature 5 to 80 C Dimensions Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page (3.6) OUT RS F6/0DLP + L (3.7) CH H C D E F] 7

13 3 4 C H L C C Series PCW 8 Point Input/Output Unit: HI/LO Setting Type Terminal lock: DIN Rail Mount Type Dimensions Models Input Output Specifications PCW PCW L H CN CN (3.7) RS + F8/D- CH Weight 05g mbient temperature 5 to 80 C Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page. Terminal lock: ox Mount Type Dimensions M3 x ø5 machined for bar ring Mounting hole CN CN IN OUT (3.7) 59 CH D/8- Models 8 8 () (3) Input Output PCW PCW ø4 70 -ø8 5 Specifications 5 Weight mbient temperature 365g 5 to 80 C Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page. HI/LO setting (8 point input/output unit) Since most PLC manufacturers use 6 points of input/output in units of one channel, 8 point input/output units can be connected in a series of two units. In this case, either the Lo 0 to 7 or Hi 8 to F address can be selected by means of these jumpers (short-circuit sockets). To select the Lo side address the Lo side is shorted. It is set to the Lo side when shipped from the factory. Note) When two 8 point input/output units are used in a cascade connection, set the jumpers (short-circuit sockets) so that the jumpers (short-circuit sockets) of both units are not set to the same address (i.e., not Lo and Lo or Hi and Hi ). (Trouble will occur during input due to the activation of OR circuits for two sensors.) Use caution, because incorrect connection of input and output for 8 point or 6 point input/output units following the branch unit, will cause short-circuiting of the power supply. L H Lo L H Hi 8

14 + Terminal lock: DIN Rail Mount Type HI LO HI LO PCW-9930 PCW-993 PCW-993 PCW g 5 to 80 C Dimensions F8/ID- (3.7) CN CN RS + C C IN OUT HI CH 8 9 C D E F Terminal lock: ox Mount Type Models Input Output HI LO HI LO PCW-9934 PCW-9935 PCW-9936 PCW g 5 to 80 C Dimensions -ø5 70 HI IN OUT 67.4 C C Series PCW 8 Point Input/Output Unit: HI/LO Limit Type Models Specifications Input Output Weight mbient temperature Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page. Specifications Weight mbient temperature Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page. CN CN CH MDP/8H 8 () 4. () 9 HI/LO limit type For this type, the upper or lower position is fixed, and it is not necessary to set jumpers (short-circuit sockets). Lo type: The address assignment is fixed at Lo 0 to 7. Hi type: The address assignment is fixed at Hi 8 to F.

15 + ddress Series PCW 8 Point Input/Output Unit: HI/LO Limit Type Connector: DIN Rail Mount Type Master Slave Models Models HI (master) Input Output PCW PCW LO (slave) Input Output PCW PCW Specifications Specifications Weight mbient temperature Dimensions 75g 5 to 80 C Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page. Weight mbient temperature Dimensions 55g 5 to 80 C Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page (3.6) (3.6) CN-PS + CN-PC IN RS- RS- CN-0 CN- F8/DT- CN- CN-3 CH 3 + S CN-4 3 IN CN-5 00 CN-PC CN-6 + CN-7 CN-PS H L CN-0 (8) CN- (9) CN- () CN-4(C) CN-5 (D) CH F8/DT- CN-3 () CN-6 (E) CN-7 (F) CN-PC 3 + S CNPS Cascade connection connector type 8 point input/output unit can be used with a cascade connection of a master unit and slave unit, or a cascade connection of a master unit with another device. Note) Connector type input/output units are not available with HI/LO settings. Cascade connection examples (Consult with SMC in case of a cascade connection.). st unit: Connector type 8 point input/output unit. st unit: Connector type 8 point output unit 3. st unit: Relay terminal (master unit) (master unit) nd unit: Connector type 8 point input/output unit nd unit: Connector type 8 point input/output unit nd unit: Manifold (slave unit) (slave unit) Connector type 8 point I/O unit (master) CN-PC CN-PC Connector type 8 point I/O unit (slave) CN-PC CN-PC Connector type 8 point output unit (master) CN-PC Manifold solenoid valves 8 point relay terminal Matsushita Electric Works RTS-OD08-V-S RTS-ID08-V-S Connector type 8 point I/O unit (slave) CN-PC ddress 0 to 7 ddress 8 to F ddress 0 to 7 ddress 8 to F ddress 0 to 7 ddress 8 to F Caution Connectors are manufactured by Molex Japan Co., Ltd., and are not handled by SMC. Please order them separately. Housing: , Crimp pin:

16 Series PCW PC Wiring System Connector Cable For Connection of PLC Input/Output Card to PCW Unit PLC input/output card to PCW branch unit PLC input/output card to PCW 3 point unit PCW Dimensions Power supply line Symbol Nil N Power supply line Yes No Series PCW-0 With power lines PLC connection side PCW unit connection side Lead wire length Symbol Lead wire length 0.5m m.5m m 3m 5m Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table Specifications above. Symbol Specifications 0 Standard specifications 05 For connection of PCW unit for Keyence Corp. PLC I/O card (KZ-C3X, KZ-C3T) 06 For connection of PCW unit for Hitachi, Ltd. PLC I/O card (XDC4DH, YTR4DH) Note) When using a PCW unit equipped with Fujitsu FCN connector, contact your SMC sales representative as the connector cable is different. Without power lines PLC connection side PCW unit connection side Fujitsu FCN 40 pin connector MIL-C pin connector Fujitsu FCN 40 pin connector MIL-C pin connector Series PCW-05 With power lines PLC connection side PCW unit connection side PLC connection side Without power lines PCW unit connection side MIL-C pin connector MIL-C pin connector MIL-C pin connector MIL-C pin connector Series PCW-06 With power lines PLC connection side PCW unit connection side PLC connection side Without power lines PCW unit connection side MIL-C pin connector MIL-C pin connector MIL-C pin connector MIL-C pin connector

17 Series PCW PC Wiring System Connector Cable ranch Unit: Connection of PLC Direct Connecting Type to PCW Unit ranch unit: Connection of PLC direct connecting type to PCW 6 point unit ranch unit: Connection of PLC direct connecting type to PCW 8 point unit ranch Unit: Connection of PLC Direct Connecting Type to Manifold Solenoid Valves ranch unit: Connection of PLC direct connecting type to manifold solenoid valves PCW PCW 04 V 005 Lead wire length Lead wire length Dimensions Symbol Nil N Symbol Power supply lines Power supply lines Yes No Lead wire length 0.5m m.5m m 3m 5m Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above. Dimensions Symbol V N Symbol Power supply lines Yes No Lead wire length 0.5m m.5m m 3m 5m Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above. Power supply lines pplicable manifold solenoid valve kit G kit J kit Refer to the section starting on page 6 for details regarding applicable manifold solenoid valves. With power lines ranch unit: PLC direct connecting type connection side PCW unit connection side With power lines ranch unit: PLC direct connecting type connection side Manifold solenoid valve connection side (G kit) IDEC Izumi JMS 0 pin connector MIL-C pin connector IDEC Izumi JMS 0 pin connector MIL-C pin connector Without power lines ranch unit: PLC direct connecting type connection side PCW unit connection side Without power lines ranch unit: PLC direct connecting type connection side Manifold solenoid valve connection side (J kit) IDEC Izumi JMS 0 pin connector MIL-C pin connector IDEC Izumi JMS 0 pin connector MIL-C pin connector

18 Series PCW PC Wiring System Connector Cable Connection of PCW Unit to PCW Unit Connection of PCW branch unit to PCW 6 point unit Connection of PCW branch unit to PCW 8 point unit Connection of PCW 8 point unit to PCW 8 point unit PCW 0 Symbol Nil N 005 Lead wire length Symbol Lead wire length m 00 m 05.5m 00 m 030 3m 050 5m Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above. Power supply lines Power supply lines Yes No Connection of PCW Unit to Manifold Solenoid Valves Connection of PCW branch unit to manifold solenoid valves Connection of PCW 8 point unit to manifold solenoid valves PCW 0 V Symbol V N 005 Lead wire length Symbol Lead wire length m 00 m 05.5m 00 m 030 3m 050 5m Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above. Power supply lines Power supply lines Yes No pplicable manifold solenoid valve kit G kit J kit Refer to the section starting on page 6 for details regarding applicable manifold solenoid valves. Dimensions With power lines PCW unit connection side PCW unit connection side Dimensions PCW unit connection side With power lines Manifold solenoid valve connection side (G kit) MIL-C pin connector MIL-C pin connector MIL-C pin connector MIL-C pin connector PCW unit connection side Without power lines PCW unit connection side PCW unit connection side Without power lines Manifold solenoid valve connection side (J kit) MIL-C pin connector MIL-C pin connector MIL-C pin connector MIL-C pin connector 3

19 Series PCW Check Unit Specifications Rated voltage Rated current Withstand voltage Terminal block Thread tightening torque (Phillips screw driver/flat head screw driver) Wire stripping length Connecting wire size mbient temperature 4VDC kV 0.4 to 0.6Nm/0.4 to 0.7Nm 7mm WG6 to 4 (0.3 to.5mm²) 5 to 80 C Dimensions Effective for software/hardware debugging and maintenance of PC wiring systems and other compatible systems. Signal monitoring possible with LED. Switches allow forced release and forced ON operation of connections between connectors in one bit increments. llows voltage measurement and wave form observation of signals between the check terminal and common terminal. 30 (49) How to Order PCW (4) Check unit Internal Circuit Diagram 4

20 5

21 Manifold Valves P. 8 P. 8 5 Port Solenoid Valve Series SQ000/000 Low profile compact manifold Stacking manifold type makes it easy to increase or decrease the number of stations Maintenance of valves is simplified by the one-screw mounting variety of options ack pressure check valve, uilt-in silencer, Name plate, etc. Seal type allows selection of metal seals or rubber seals P. 34 Rubber Seal 5 Port Solenoid Valve Series SX3000/5000 Low power consumption: 0.65W (with light) (Current value: 7m, 4VDC) Compact with high flow rate Cv factor.7 to 3 times greater with same body width as previous series High reliability Long life exceeding 50 million cycles Main valve and pilot valve common exhaust construction eliminates pilot valve exhaust mist and noise P. 54 P. 44 Rubber Seal 5 Port Solenoid Valve Series SZ3000 Size and weight reductions have been realized by eliminating the manifold base The plug-in cassette system makes valve replacement easy plug-in manifold has been achieved with a height of 43.5mm (including DIN rail) Valves with switches are available to allow each valve to be turned off individually 4 position dual 3 port valve provided by combining two 3 port valves in one valve body Valve with back-pressure check function available Low power consumption: 0.65W (with light) (Current value: 7m, 4VDC) Rubber Seal 5 Port Solenoid Valve Series SY3000/5000 Low power consumption: 0.55W (with light) (Current value: 3m, 4VDC) Compact with high flow rate Cv factor.7 to 3 times greater with same body width as previous series High reliability Long life exceeding 50 million cycles Main valve and pilot valve common exhaust construction eliminates pilot valve exhaust mist and noise 5 Port Solenoid Valve ody Ported Type/Flip Plug-in Unit Series VQ000 Compact manifold for efficient use of space Valves can be replaced without disassembling the entire manifold Seal type allows selection of metal seals or rubber seals 5 Port Solenoid Valve ase Mounted Type/Plug-in Unit Series VQ000/000 Space saving design locates all pilot valves on one side One-clamp construction with no screws for easy valve replacement variety of options ack pressure check valve, uilt-in silencer, Name plate, etc. Seal type allows selection of metal seals or rubber seals 6

22 Manifold Valve Common Specifications Manifold Electrical Wiring With power supply terminals (G kit) Electrical circuit diagram (The wiring below indicates all double solenoid connections) 4VDC + station { stations { 3 stations { 4 stations { 5 stations { 6 stations { 7 stations { 8 stations { SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. pplicable series Series SZ3000 Series SX3000/5000 Series SY3000/5000 Series VQ000/000 (base mounted type) Terminal no For standard electrical wiring specifications, the internal wiring for up to eight stations is double wiring (connected to SOL. and SOL.) for each station regardless of the valve or option type. Connect to SOL. in case of single solenoids. Furthermore, when mixed single and double wiring is required, indicate this on a manifold specification sheet. (except Series SY) Without power supply terminals (J kit) Electrical circuit diagram (The wiring below indicates all double solenoid connections) station { stations { 3 stations { 4 stations { 5 stations { 6 stations { 7 stations { 8 stations { Terminal no SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. pplicable series Series SQ000/000 Series VQ000 (body ported) Series VQ000/000 (base mounted type) For standard electrical wiring specifications, the internal wiring for up to eight stations is double wiring (connected to SOL. and SOL.) for each station regardless of the valve or option type. Connect to SOL. in case of single solenoids. Furthermore, when mixed single and double wiring is required, indicate this on a manifold specification sheet VDC ( ). 4VDC (+) Common Shared Wiring Connectors Common shared wiring connector assemblies are also available for series SX/SZ. Refer to the catalog for each series for details. 7

23 5 Port Solenoid Valve Series SQ000/000 Low profile compact manifold Stacking manifold type makes it easy to increase or decrease the number of stations Maintenance of valves is simplified by the one-screw mounting variety of options ack pressure check valve, uilt-in silencer, Name plate, etc. Seal type allows selection of metal seals or rubber seals Type of actuation, port size position 3 position 4 position One-touch fitting Series Effective area mm² (Cv factor) Single/Double Single Double (Latching/ Double solenoid) Closed center Exhaust center Pressure center Dual 3 port valve C3 (ø3.) C4 (ø4) (ø6) C8 (ø8) SQ30 Metal seal SQ3 Rubber seal SQ30 Metal seal SQ3 Rubber seal 3. (0.8) 4.5 (0.5).7 (0.65) 4.8 (0.8) 8

24 Series SQ000/000 How to Order Manifolds SS5Q 3 08 JD0 D N (-00T) Series Symbol Series SQ000 SQ000 Valve stations Symbol 0 station 6 6 stations Set the maximum number of stations so that there are no more than 6 solenoids for 9 or more stations. The solenoids are counted as Single : point Double, 3P: points Dual 3 port: points Manifold mounting Symbol Mounting D DIN rail mount type E Direct mount type Options Symbol 0 to 4 K N R S P, R port inch bore size Option specifications Specifies DIN rail length ack pressure check valve on all stations Special wiring specification (except double wiring) With name plate (valve with side port specification only) External pilot specification uilt-in silencer Note ) In case of two or more options, enter in alphabetical order. Example: DS Note ) Indicate DIN rail length as D ( indicates stations). Example: D08 In this case, an eight station DIN rail will be provided regardless of the number of manifold stations. Note 3) Indicate wiring specifications on a manifold specification sheet. How to Order Valves SQ 3 Y 5 Note ) Note ) Note ) C Note ) 0 Symbol Nil D K Note ) Y Note ) R Note ) Type of actuation position single position double (latching/double solenoid) 3 position closed center 3 position exhaust center 3 position pressure center Dual 3 port valve N.C. + N.C. Dual 3 port valve N.O. + N.O. Dual 3 port valve N.C. + N.O. Note ) The function symbol is "D" for double solenoid specifications. Note ) vailable only for rubber seal type. Seal type Metal seal Rubber seal Series SQ000 SQ000 Function Specifications Standard type (W) position double (double solenoid specification) High pressure type (MPa W) vailable only for SQ000 with metal seal Low power consumption type (0.5W) External pilot specification Note ) Except double (latching) type Note ) Except dual 3 port valve Note 3) When specifying two or more options, enter symbols in alphabetical order. Coil voltage Symbol Voltage 5 4VDC Note) The light/surge voltage suppressor is built-in. Port plug mounting port Symbol Nil Specifications None port port Cylinder port size Symbol C3 C4 C8 L3 L4 L6 L8 Cylinder port size With One-touch fitting for ø3. With One-touch fitting for ø4 With One-touch fitting for ø6 With One-touch fitting for ø8 With One-touch fitting for ø3. With One-touch fitting for ø4 With One-touch fitting for ø6 With One-touch fitting for ø8 SQ000 Note) Inch sizes use the following symbols. N: ø/8" (SQ000 only) N3: ø5/3" N7: ø/4" N9: ø5/6" (SQ000 only) Manual operation Symbol Specifications SQ000 Nil Non-locking push type (tool required) Note) Slotted locking type (tool required) D Note) Slide locking type (manual type) Note) Except double (latching) Manifold block Symbol Specifications Nil Note ) Without manifold block M Note ) With manifold block M Note ) With manifold block uilt-in back pressure check valve Note ) When ordered with manifold When only valve is required Note ) For station additions SQ000 SQ000 Piping specifications Side ported Top ported 9

25 5 Port Solenoid Valve Series SQ000/000 Models Standard Specifications Series Note ) Note ) Number Effective area Response time ms of Weight Model mm² solenoids Standard: Low (Cv factor) g W power Single Metal seal SQ30 3. (0.8) or less 5 or less 80 Rubber seal SQ3 4.5 (0.5) 5 or less 0 or less 80 Double Metal seal SQ30 3. (0.8) 5 or less 80 (latching) Rubber seal SQ3 4.5 (0.5) 0 or less 80 Double Metal seal SQ30D 3. (0.8) 0 or less 3 or less 95 (double solenoid) Rubber seal SQ3D 4.5 (0.5) 5 or less 0 or less 95 Closed Metal seal SQ330.9 (0.6) 0 or less 6 or less 00 center Rubber seal SQ33 3. (0.8) 5 or less 33 or less 00 Exhaust Metal seal SQ (0.8) 0 or less 6 or less 00 center Rubber seal SQ (0.5) 5 or less 33 or less 00 Pressure Metal seal SQ530.9 (0.6) 0 or less 6 or less 00 center Rubber seal SQ53 3. (0.8) 5 or less 33 or less 00 Dual Rubber seal SQ 3 3 port valve C 3. (0.8) 5 or less 33 or less 95 Single Metal seal SQ30.7 (0.65) 0 or less 6 or less 45 Rubber seal SQ3 4.8 (0.8) 4 or less 3 or less 40 Double Metal seal SQ30.7 (0.65) 6 or less 45 (latching) Rubber seal SQ3 4.8 (0.8) 3 or less 40 Double Metal seal SQ30D.7 (0.65) 5 or less 0 or less 60 (double solenoid) Rubber seal SQ3D 4.8 (0.8) 0 or less 6 or less 55 Closed Metal seal SQ (0.45) 34 or less 44 or less 80 center Rubber seal SQ (0.5) 34 or less 44 or less 75 Exhaust Metal seal SQ430.7 (0.65) 34 or less 44 or less 80 center Rubber seal SQ43.6 (0.7) 34 or less 44 or less 75 Pressure Metal seal SQ (0.45) 34 or less 44 or less 80 center Rubber seal SQ (0.5) 34 or less 44 or less 75 Dual 3 port valve Rubber seal SQ 3 C 9.0 (0.5) 34 or less 44 or less 55 SQ000 SQ000 position 3 position 4 position position 3 position 4 position Note ) SQ000 values are for cylinder port size. SQ000 values are for top ported type with cylinder port size C8. Side ported type is approximately 0% smaller. Note ) ased on JIS (Values for supply pressure of 0.5MPa with light/surge voltage suppressor. This will change depending on pressure and air quality.) Valve construction Metal seal Rubber seal Fluid Maximum operating pressure ir, Inert gas Note 3) 0.7MPa (High pressure type:.0mpa) Single Minimum Double (latching) operating Double (double solenoid) 0.MPa 0.8MPa 0.MPa 0.5MPa 0.8MPa 0.MPa pressure 3 position 4 position 0.MPa 0.MPa 0.5MPa mbient and fluid temperature 0 to 50 C Note ) Lubrication Not required Manual operation Push type/slotted locking type (tool required) Note ) Impact/Vibration resistance 30/50m/s² Enclosure Dust proof Note ) In case of low temperature, use dry air with no condensation. Note ) Vibration resistance No malfunction when tested with one sweep of 8.3 to 000Hz in the axial direction and at a right angle to the main valve/armature, one time each with and without current. (initial values) Impact resistance.. No malfunction when tested with a drop and impact tester in the axial direction and at a right angle to the main valve/armature, one time each with and without current. (initial values) Note 3) SQ000 metal seal type only {except double (latching)} Solenoid Specifications Rated coil voltage 4VDC llowable voltage fluctuation ±0% of rated voltage Coil insulation type Class equivalent Power consumption DCW (4m) 4VDC (current value) DC0.5W (m) Note) Note) Value for the low power consumption (0.5W) specification Manifold Specifications Series SQ000 SQ000 ase type Piping specifications Note ) Port size P, R, Piping Port size C3 (for ø3.) C8 (for ø8) Side C4 (for ø4) (for ø6) SS5Q3- - Option Note ) L3 (for ø3.) uilt-in silencer Top L4 (for ø4) Direct exhaust L6 (for ø6) C0 C4 (for ø4) (for ø0) Side L6 (for ø6) C8 (for ø8) SS5Q3 - Option Note ) uilt-in L4 (for ø4) Silencer Top (for ø6) Direct exhaust C8 (for ø8) pplicable solenoid valve SQ30 SQ3 SQ30 SQ3 Type of connection J kit: Flat cable J kit: Flat cable Note 3) Note 4) Note 4) pplicable stations to 8 stations to 8 stations 5 station weight g Note ) One-touch fittings for inch sizes are also available. Note ) Side ports can be changed. Note 3) The maximum number of stations can be expanded with optional special wiring specifications. Note 4) Except valve weight dditional weight of station g

26 Series SQ000/000 SQ000/Flat Cable Kit SS5Q3- JD0 L4 5.5 L (mounting hole dimension) M5: External pilot port L L P = Indicator light Manual override (08.5) (3 position) 3 {double (double solenoid) dual 3 port valve} 08.5 {single, double (latching)} TURN.TURN.PUSH.PUSH pprox pplicable connector: Flat cable connector (0P) (conforms to MIL-C-83503) pprox. 9 Triangle mark indicator position EXH. outlet Release for switching connector direction D side C8: R(EXH) port C8: P(SUP) port Station n R 3 4 For top ports U side -M4 clamping screw 60 pprox P P =.5 n-c3, C4,, port Dimensions Formulae L =.5n L =.5n + 73 n: (max. 6 stations) L n L L L3 L

27 5 Port Solenoid Valve Series SQ000/000 SQ000/Flat Cable Kit SS5Q3- JD (mounting hole dimension) M5: External pilot port Release for switching connector direction P = 7.5 L4 L3 L L 8.8 Indicator light Manual override (3.5) SMC 47 (3 position) 3.5 (single, double, dual 3 port valve) M4 clamping screw pplicable connector: Flat cable connector (0P) (conforms to MIL-C-83503) pprox. pprox. Triangle mark indicator position EXH. outlet C0: R(EXH) port C0: P(SUP) port D side Station n For top ports U side pprox. 0 R (58) 39.5 P P = 7.5 n-c4,,c8, port Dimensions Formulae L = 7.5n + 5 L = 7.5n n: (max. 6 stations) L n L L L3 L

28 Manifold Specification Sheet Series SQ000/Plug-in Unit. How to Order Manifolds SS5Q 3 08 J D0 D N ( 00T) Series VQ Plug-in For P, R port inch size Kit designation 0 station 6 6 stations Electrical entry/cable length Kit Entry Kit, Cable length designation direction J 3 D E JD0 D side Manifold mounting DIN rail mount type Direct mount type Flat cable (0P) kit for PC wiring system Without cable Note ) Standard stations to 8 (6) Note ) Order cable assembly separately. Note ) Numbers inside ( ) indicate the maximum number of solenoid stations for mixed single/double wiring. The maximum number of stations is determined by the total number of solenoids. When ordering mixed wiring, add the option symbol "-K". 4 Nil 0 to 4 K N R S Options None Specifies DIN rail length Note ) With back pressure check valve on all stations Special wiring specifications (except double wiring) Note 3) With name plate (valve with side port specification only) External pilot specification uilt-in silencer Note ) In case of two or more options, enter in alphabetical order. Example: DS Note ) Indicate DIN rail length as D. ( indicates stations) Example: D08 In this case, an eight station DIN rail will be provided regardless of the number of manifold stations. Note 3) e sure to indicate wiring specifications on a specification sheet.. How to Order pplicable Valves SQ 3 Y 5 Series SQ000 C D E F G H.PUSH.PUSH Type of actuation position single Note ) position double (latching/double solenoid) 3 3 position closed center 4 3 position exhaust center 5 3 position pressure center Note ) Dual 3 port valve N.C. + N.C. Note ) Dual 3 port valve N.O. + N.O. C Note ) Dual 3 port valve N.C. + N.O. Note ) The function symbol is D for double solenoid specifications. Note ) vailable only for rubber seal type Seal type 0 Metal seal Rubber seal C Function Nil Standard type (W) D position double (double solenoid specification) K Note ) N Y Note ) R Note ) High pressure type (.0MPa, W) available only for metal seal Negative common Low power consumption type (0.5W) External pilot specifications Note ) Except double (latching) type Note ) Except dual 3 port valve Note 3) When specifying more than one option, enter symbols in alphabetical order. D Coil voltage 5 4VDC Note) The light/surge voltage suppressor is built-in. E Manual operation Nil Non-locking Note ) push type (tool required) Slotted locking type (tool required) Note ) Except double (latching) F Cylinder port size C3 C4 L3 L4 L6 With One-touch fitting for ø3. With One-touch fitting for ø4 With One-touch fitting for ø6 With One-touch fitting for ø3. With One-touch fitting for ø4 With One-touch fitting for ø6 G Port plug mounting port Nil None port port Side ported Top ported Note) Inch sizes use the following symbols. N: ø/8 N3: ø5/3 N7: ø/4 Top ports are indicated by LN. D side Station n U side ) are counted starting from station on the D side. H Manifold block Nil Note ) Without manifold block M Note ) With manifold block M Note ).TURN.TURN With manifold block uilt-in back pressure check valve Note ) When ordered with manifold When only valve is required Note ) For station addition 3

29 Manifold Specification Sheet Series SQ000/Plug-in Unit Manifold Models SS5Q 3 JD0 D E Company name Contact person Specification sheet no. Purchase order no. Date / / Equipment name (Circle the applicable item) Quantity set(s) Required date Specifications Description/Model Station D side U side Enter an X in the required locations Single Double (latching) Metal Rubber Double (double solenoid) Metal Rubber Valves Closed center Exhaust center Pressure center Options Note 4) Cylinder port sizes Dual 3 port valve () Dual 3 port valve () Dual 3 port valve (C) N.C. N.O. lanking plate SSQ Supply/Exhaust block SSQ000-PR-3-C8- (S) ack pressure check valve Note ) SSQ000-P SUP block bushing SSQ000--P P EXH block bushing SSQ000--R R Port plug Note ) Special wiring specifications For ø3. (ø/8 ) With One-touch fitting For ø4 (ø5/3 ) With One-touch fitting For ø6 (ø/4 ) With One-touch fitting Note 3) Description/Model N.C. N.O N.C. N.O. Single wiring Double wiring C3 (N) C4 (N3) (N7) Station Notes Note ) When installing on all manifold stations, use "" for the manifold part number option symbol. When installing only on required station positions, specify the part number and indicate the station positions on the specification sheet. Note ) When using port plugs, circle the specified ports. Note 3) In case of single wiring or mixed wiring, connections to the connector terminals start from the side solenoid of station and continue in order without skipping any terminals. Note 4) In case of valves with top port specifications, enter "L" in the specification table. pplicable valves and options SMC use only Part no. Qty. Part no. Qty. Order no. Clerk (code no.) Dept. code Copy this page for use as needed. 4

30 Manifold Specification Sheet Series SQ000/Plug-in Unit. How to Order Manifolds SS5Q 3 08 J D0 D N ( 00T) Series VQ Plug-in For P, R port inch sizes Kit designation 0 station 6 6 stations D E Electrical entry/cable length Note ) Kit designation Entry direction J JD0 D side Flat cable (0P) kit for PC wiring system to 8 (6) Without cable Note ) Order cable assembly separately. Note ) Numbers inside ( ) indicate the maximum number of solenoids for mixed single/double wiring. The maximum number of stations is determined by the total number of solenoids. In case of mixed wiring, add the option symbol "-K". 3 Manifold mounting DIN rail mount type Direct mount type Kit, Cable length Standard stations 4 Nil 0 to 4 K N R S Option None Specifies DIN rail length Note ) With back pressure check valve on all stations Special wiring specifications (except double wiring) Note 3) With name plate (valve with side port specification only) External pilot specification uilt-in silencer Note ) In case of two or more options, enter symbols in alphabetical order. Example)-DS Note ) Indicate DIN rail length as D. ( indicates stations) Example: D08 In this case, an eight station DIN rail will be provided regardless of the number of manifold stations. Note 3) e sure to indicate wiring specifications on a specification sheet.. How to Order pplicable Valves SQ 3 Y 5 Series SQ000 C D E F G Type of actuation Note ) Note ) Note ) C Note ) Seal type 0 Metal seal Rubber seal C Function Nil D N Y Note ) R Note ) position single position double (latching/double solenoid) 3 position closed center 3 position exhaust center 3 position pressure center Dual 3 port valve N.C. + N.C. Dual 3 port valve N.O. + N.O. Dual 3 port valve N.C. + N.O. Note ) The function symbol is D for double solenoid specifications. Note ) vailable only for rubber seal type Standard type (W) position double (double solenoid specification) Negative common Low power consumption type (0.5W) External pilot specification Note ) Except double (latching) type Note ) Except dual 3 port valve Note 3) When specifying two or more options, enter symbols in alphabetical order D Coil voltage 5 4VDC Note) The light/surge voltage suppressor is built-in. E Manual operation Nil Non-locking push type (tool required) Slotted locking type (tool required) Note ) D Note ) Slide lock type (manual): vailable only with side ports Note ) Except double (latching) F Cylinder port size C4 With One-touch fitting for ø4 With One-touch fitting for ø6 C8 With One-touch fitting for ø8 L4 With One-touch fitting for ø4 L6 With One-touch fitting for ø6 L8 With One-touch fitting for ø8 Side ported Top ported Note) Inch sizes use the following symbols. N3: ø5/3 N7: ø/4 N9: ø5/6 Top ports are indicated by LN. G Manifold block Nil Note ) M Note ) MNote ) D side Station n U side ) are counted starting from station on the D side. Without manifold block With manifold block With manifold block uilt-in back pressure check valve Note ) When ordered with manifold When only valve is required Note ) For station addition 5

31 Manifold Specification Sheet Series SQ000/Plug-in Unit Manifold Models SS5Q 3 JD0 D E Company name Contact person Specification sheet no. Purchase order no. Date / / Equipment name (Circle the applicable item) Quantity set(s) Required date Specifications Description/Model Single Double (latching) Double (double solenoid) Metal Metal Rubber Rubber Station D side U side Enter an X in the required locations Valves Closed center Exhaust center Pressure center Options Note 4) Cylinder port sizes Dual 3 port valve () Dual 3 port valve () Dual 3 port valve (C) N.C. lanking plate SSQ Supply/Exhaust block Note ) SSQ000-PR-3-C0- (S) ack pressure check valve SSQ000-P SUP block bushing SSQ000--R EXH block bushing SSQ000--R Port plug For ø4 (ø5/3 ) With One-touch fitting For ø6 (ø/4 ) With One-touch fitting For ø8 (ø5/6 ) With One-touch fitting Special wiring specifications Note 3) Description/Model N.C. N.O N.C. N.O. N.O. P Single wiring Double wiring R C4 (N3) (N7) C8 (N9) Station Notes Note ) When installing on all manifold stations, use "" for the manifold part number option symbol. When installing only on required station positions, specify the part number and indicate the station positions on the specification sheet. Note ) When using port plugs, circle the specified ports. Note 3) In case of single wiring or mixed wiring, connections to the connector terminals start from the side solenoid of station and continue in order without skipping any terminals. Note 4) In case of valves with top port specifications, enter "L" in the specification table. pplicable valves and options SMC use only Part no. Qty. Part no. Qty. Order no. Clerk (code no.) Dept. code Copy this page for use as needed. 6

32 7

33 Rubber Seal 5 Port Solenoid Valve Series SZ3000 Size and weight reductions have been realized by eliminating the manifold base The plug-in cassette system makes valve replacement easy plug-in manifold has been achieved with a height of 43.5mm (including DIN rail) Valves with switches are available to allow each valve to be turned off individually 4 position dual 3 port valve provided by combining two 3 port valves in one valve body Valve with back-pressure check function available Low power consumption: 0.65W (with light) (Current value: 7m, 4VDC) Type of actuation, port size position 3 position 4 position One-touch fitting Series Effective area mm² (Cv factor) Single Double Closed center Exhaust center Pressure center Dual 3 port valve M5 C4 L4 (ø4) L6 (ø6) SZ (0.) 8

34 Series SZ3000 How to Order Manifolds SS5Z3 60GD 05 U Connector entry direction Connector vertical Connector horizontal Symbol stations 8 stations stations 6 stations Valve stations Note Double wiring specification Specified wiring (up to 6 solenoids are possible) Note ) Double wiring specifications: Single, double, 3 position and 4 position solenoid valves can be used at all of the manifold stations. Specified layout: Indicate the wiring specifications on a manifold specification sheet. (Please note that in locations where single solenoid wiring is indicated, it will be impossible to use double or 3 and 4 position valves.) Note ) The number of blanking blocks is also included. Supply/Exhaust block assembly mounting position U U Side ( to 0 stations) D D Side ( to 0 stations) oth sides ( to 6 stations) M Special specifications For special specifications, indicate them separately on a manifold specification sheet. Note) total of up to 3 supply/exhaust blocks can be mounted. Contact SMC if 4 or more will be mounted. Options Supply/Exhaust block assembly fitting specifications Nil L Straight Elbow fitting (upward) Elbow fitting (downward) Pilot specifications Nil Internal pilot specification R External pilot specification When a DIN rail is required that is longer than the standard types, specify the number of stations. (max. 0 stations) How to Order Valves SZ LOZ Type of actuation C position single solenoid position double solenoid 3 position closed center 3 position exhaust center 3 position pressure center 4 position dual 3 port valve: N.C./N.C. 4 position dual 3 port valve: N.O./N.O. 4 position dual 3 port valve: N.C./N.O. Pilot specifications Nil Internal pilot R External pilot Note) 4 position dual 3 port valves are not available with external pilot specification. Switch specifications Nil J Without switch With switch Manual override Nil D Non-locking push type Slotted locking type How to Order Manifold ssemblies (Example) Example (SZ3000, positive common with power supply terminals) Single solenoid Double solenoid SZ360-5LOZ- ( sets) LOCK FREE Manifold SS5Z3-60GD-05U SZ360-5LOZ- (3 sets) Supply/Exhaust block (U side mounting) D side 3 Station U side 9 ack pressure check valve None uilt-in Nil K Note ) The effective area is reduced by about 0% for the built-in back pressure check valve type. Note ) 3 position closed center and 3 position pressure center are not available with back pressure check valve. Rated voltage 5 4VDC C4 M5 L4 L6 4 6, port size ø4 One-touch fitting ø6 One-touch fitting M5 x 0.5 ø4 elbow fitting assembly (upward) ø6 elbow fitting assembly (upward) ø4 elbow fitting assembly (downward) ø6 elbow fitting assembly (downward) SS5Z3-60GD-05U... set (manifold part number) SZ360-5LOZ-... sets (single solenoid part number) SZ360-5LOZ sets (double solenoid part number) The " " symbol indicates mounting. Put the " " symbol at the beginning of part numbers for solenoid valves, etc., which are to be mounted. Valve stations are numbered from station on the D side. Indicate the valves to be mounted below the manifold part number, in order starting from station as shown in the drawing. When a layout becomes complicated, please indicate on a manifold specification sheet.

35 Cassette Type Manifold Series SZ3000 Manifold Specifications Solenoid Valve Specifications Model Manifold type P (SUP), R (EXH) system Valve stations Note ), port piping specifications Port size Note ) Valve effective sectional area mm² (Cv factor) C4 M5 Location Direction P, R ports / ports P / / R P / / R P / / R Weight W (g) Note 3) n: n: Number of supply/exhaust blocks m : Weight of DIN rail Flat cable type 60G Plug-in type Common SUP, EXH to 6 stations Valve Side C8 C4,, M5 3.4 (0.9) [3.0 (0.7)] 3. (0.8) [3. (0.8)] 3.7 (0.) [3. (0.8)] 3.9 (0.) [3.8 (0.)] 3.4 (0.9) [3. (0.8)] 3. (0.8) [3. (0.8)] W = 3.n + 53n + m Note ) vailable with up to 6 solenoids. When a large number of valves will be operated simultaneously, use type (supply/exhaust on both sides), applying pressure to the P ports on both sides and releasing exhaust from the R ports on both sides. Note ) The value is for manifold base mounting (5 stations). position type with single action. Values inside [ ] are for 4 position dual 3 port valves. Furthermore, when the and sides of a 4 position dual 3 port valve are operated simultaneously, the Cv factor will be about 35% less than in the table above. The Cv factor for valves with back pressure check valve will be about 0% less than in the table above. Note 3) The weight W is the value for the manifold only. To obtain the weight with solenoid valves, add the solenoid valve weights for the required number of stations. Refer to the separate catalog ES-75 regarding DIN rail weight. Series Fluid SZ3000 ir Internal pilot operating pressure range MPa External pilot position single position double 3 position 4 position dual 3 port valve Operating pressure range 0.5 to to to to kPa to 0.7 operating Pilot position single pressure range pressure position double 0.5 to 0.7 MPa range 3 position mbient and fluid temperature C frequency Hz 3 position Manual override Pilot system Lubrication Mounting orientation Impact/Vibration resistance m/s Note) Enclosure Maximum position single, double operating 4 position dual 3 port valve Maximum Non-locking push type, Slotted locking type Main valve, pilot valve common exhaust type Not required Unrestricted 50/30 (8.3 to 000Hz) Dust proof Note) Impact resistance: No malfunction when tested with a drop tester in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states. (Initial value) Vibration resistance: No malfunction when tested with one sweep of 8.3 to 000Hz in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states. (Initial value) Solenoid Specifications Electrical entry Rated coil voltage llowable voltage fluctuation Power consumption Surge voltage suppressor Indicator light Response Time L type (for plug-in) 4VDC ±0% of rated voltage 0.65W Diode LED Note) ased on JIS dynamic performance test (with coil temperature of 0 C and at rated voltage). Response time ms Type of actuation With light/surge voltage suppressor position single position double 3 position 4 position dual 3 port valve Weights Valve model SZ360--C4 SZ360-- SZ360--M5 position 3 position 4 position position 3 position 4 position position 3 position 4 position Type of actuation Single Double Closed center Exhaust center Pressure center Dual 3 port valve Single Double Closed center Exhaust center Pressure center Dual 3 port valve Single Double Closed center Exhaust center Pressure center Dual 3 port valve 5 or less 3 or less 0 or less 35 or less Port size, C4 ø4 One-touch fitting ø6 One-touch fitting M5 x 0.8 Weight g

36 Series SZ3000 Dimensions/SZ3000: Plug-in SS5Z3-60GD - U (Pitch) P = 0.5 n-m5 x 0.8 [4(), () port] [With external pilot] PE 4 R 3 4 P R One-touch fitting [(P), 3(R) port] pplicable tube O.D.: ø8 4 4 n-one-touch fitting [4(), () port] pplicable tube O.D.: ø4, ø6 4 P -One-touch fitting (X, PE port) pplicable tube O.D.: ø6 4 X U side (L4) 8 L3 Connector entry direction switch LOCK FREE 6.6 D side (3.) Triangle mark pplicable connector: 6 pin MIL type with strain relief (conforms to MIL-C-83503) 47.6 DIN rail 5 Manual override In case of locking type, turn after pushing in. 4 (): Orange (): Green ( ) L (Rail mounting hole pitch.5) L Power supply terminals (M3 terminal screws) 3.5 (With switch) DIN rail holding screw Triangle mark position (Station n)...(station ) Light/Surge voltage suppressor Side : Orange Side : Green ON OFF ON OFF (7.5) (DIN rail dimension) 34. (6.4) Switch (when equipped with switch) Internal pilot manifold L: Dimensions n: (n + n) L n L L L3 L External pilot manifold L: Dimensions n: (n + n) L n L L L3 L

37 Cassette Type Manifold Series SZ3000 Dimensions/SZ3000: Plug-in SS5Z3-60GD (Pitch) P = 0.5 n-m5 x 0.8 [4(), () port] 4 [With external pilot] R 3 R P n-one-touch fitting [4(), () port] pplicable tube O.D.: ø4, ø P 4-One-touch fitting [(P), 3(R) port] pplicable tube O.D.: ø8 -One-touch fitting (X, PE port) pplicable tube O.D.: ø6 P R X PE R P (3.) U side (L4) L3 Connector entry direction switch 6.6 D side pplicable connector: 0 pin MIL type with strain relief (conforms to MIL-C-83503) DIN rail LOCK FREE Triangle mark Manual override In case of locking type, turn after pushing in. 4 (): Orange (): Green ( ) L (Rail mounting hole pitch.5) L Power supply terminals (M3 terminal screws) 3.5 (With switch) 6 DIN rail holding screw Triangle mark position Light/Surge voltage suppressor side: Orange side: Green (Station n)...(station ) (8.9) 43.5 ON OFF ON OFF (7.5) (DIN rail dimension) 34. Switch (when equipped with switch) (6.4) Internal pilot manifold L: Dimensions n: (n + n) L n L L L3 L External pilot manifold L: Dimensions n: (n + n) L n L L L3 L

38 Please copy this page for use without removing it. SZ3000: Cassette Type Plug-in Manifold Manifold Valve Specification Sheet Company name Contact person Specification sheet no. Purchase order no. Equipment name Quantity set(s) Date required Date / / Make entries in order from to. How to Order Manifolds Enter the symbols for the required specifications in the blanks below. Enter an X for the manifold type to be used. SS5Z3-60GD SS5Z3-60GD Enter the symbols for the required specifications in the blanks below. SZ3 60 5LOZ Type of valve actuation position single solenoid position double solenoid 3 3 position closed center 4 3 position exhaust center 5 3 position pressure center 4 position dual 3 port valve (N.C., N.C.) 4 position dual 3 port valve (N.O., N.O.) C 4 position dual 3 port valve (N.C., N.O.) Indicate in the station table below. a b c d Standard type specifications Special Valve stations or layout Single solenoid position Double solenoid Closed center 3 position Exhaust center Pressure center 4 position SZ360 (N.C., N.C.) dual SZ360 (N.O., N.O.) 3 port valve SZ30 (N.C., N.O.) lanking block assembly External pilot specification (enter only in case of external pilot) ack pressure check valve (enter only in case of back pressure check valve) Enter for special specs. Connector entry direction Symbol Mounting position Vertical Horizontal How to Order Valves 3 Station Table Supply/Exhaust block assembly External pilot block assembly Valve stations Symbol 0 stations stations Supply/Exhaust block assembly mounting position Symbol Mounting position pplicable stations U D U side D side oth sides to 0 stations to 0 stations to 6 stations M Special specifications Indicate the supply/exhaust block and external pilot block postion in section (d) of the station table below. C Pilot type ack pressure check valve Nil Internal pilot Nil None R External pilot K ulit-in SUP blocking disk e EXH blocking disk Pilot port blocking disk Wiring Single wiring f specifications Double wiring [Note] SUP blocking disk: SZ Supply/Exhaust block assembly (ø8): SZ C8 EXH blocking disk: SZ (pcs./location) Supply/Exhaust block assembly (ø6): SZ lanking block assembly: SZ External pilot block assembly (ø6): SZ Pilot port blocking valve: SZ External pilot block assembly (ø4): SZ C4 Note) The final symbol indicates the port size for supply/exhaust block and external pilot block assemblies. For SMC use only Enter the ordered part numbers. Switch specifications Nil Without switch J With switch Manual override U side Nil D Non-locking push type Slotted locking type C, port size C4 ø4 One-touch fitting ø6 One-touch fitting M5 M5 x 0.8 L4 ø4 elbow One-touch fitting (upward) L6 ø6 elbow One-touch fitting (upward) 4 ø4 elbow One-touch fitting (downward) 6 ø6 elbow One-touch fitting (downward) M Mixed Pilot system Symbol Specifications Nil Standard/internal pilot specification R External pilot specification In case of R, external pilot block will be added. Supply/Exhaust block assembly fitting specifications Symbol Specifications Nil Straight L Elbow One-touch fitting (upward) Elbow One-touch fitting (downward) Indicate the layout of valves, etc., with "X's". When the port sizes of each block assembly are mixed or special specifications, indicate them by entering the port size symbols (C4,, etc.). 33 When an external pilot valve is to be used, enter an "X" in section (b) of the station table below. However, external pilot specifications are not available for 4 position dual 3 port valves. When a valve with back pressure check valve is used, enter an "X" in section (c) of the station table below. Options When a DIN rail is required that is longer than the standard types, specify the number of stations. (max. 0 stations) Quantity Supply/Exhaust block assembly (elbow upward): SZ L6/L8 Supply/Exhaust block assembly (elbow downward): SZ /8 External pilot block assembly (elbow upward): SZ L4/L6 External pilot block assembly (elbow downward): SZ /6 Part no. Quantity Part no. Quantity Order no. Clerk (code no.) Dept. code Note) When there are special specifications, enter part numbers and quantities for supply/exhaust block and external pilot block assemblies together with the manifold type. n m Valve stations Layout (for special specifications) LOCK FREE D side Supply/Exhaust block assembly

39 Rubber Seal 5 Port Solenoid Valve Series SX3000/5000 Low power consumption: 0.65W (with light) (Current value: 7m, 4VDC) Compact with high flow rate Cv factor.7 to 3 times greater with same body width as previous series High reliability Long life exceeding 50 million cycles Main valve and pilot valve common exhaust construction eliminates pilot valve exhaust mist and noise Type of actuation, port size position 3 position One-touch fitting Series Effective area mm (Cv factor) Single Double Closed center Exhaust center Pressure center C4 (ø4) (ø6) C8 (ø8) SX (0.6) SX540.6 (0.7) 34

40 Series SX3000/5000 SS5X 3 45G D 05 U C4 How to Order Manifolds Series 3 SX SX5000 Connector mounting position Symbol Mounting position U U side D D side Valve stations Symbol stations 8 stations stations 6 stations Note Double wiring specification Specified wiring (up to 6 solenoids are possible) Note ) Double wiring specifications: Single, double, 3 position and 4 position solenoid valves can be used at all of the manifold stations. Specified layout: Indicate the wiring specifications on a manifold specification sheet. (Please note that in locations where single solenoid wiring is indicated, it will be impossible to use double or 3 and 4 position valves.) Note ) The number of blanking plate assemblies is also included. Symbol U D M, port size SX3000 Options Mounting position pplicable stations U side to 0 stations D side to 0 stations oth sides to 6 stations Special specifications Indicate special specifications separately on a manifold specification sheet. SX5000 Symbol Port size Symbol C4 ø4 One-touch fitting C4 ø6 One-touch fitting M Mixed C8 M Indicate mixed specifications separately on a manifold specification sheet. Supply/Exhaust block assembly mounting position When a DIN rail is required that is longer than the standard types, specify the number of stations. (max. 0 stations) Port size ø4 One-touch fitting ø6 One-touch fitting ø8 One-touch fitting Mixed Symbol Nil R S RS Supply/Exhaust block assembly specifications Specifications Internal pilot specification External pilot specification Internal pilot specification/uilt-in silencer External pilot specification/uilt-in silencer SX 3 40 Series 3 SX SX5000 Type of actuation position single position double 3 3 position closed center 4 3 position exhaust center 5 3 position pressure center How to Order Valves 5LOZ Rated voltage 5 4VDC Manual override Nil Non-locking push type D Slotted locking type How to Order Manifold ssemblies Example Supply/Exhaust block (U side mounting) Double solenoid SX340-5LOZ ( sets) Single solenoid SX340-5LOZ (3 sets) Manifold SS5X3-45GD-05U-6 Nil R Pilot type Internal pilot External pilot U side Station D side 4VDC -COM SMC SS5X3-45GD-05U-... set (manifold part number) SX340-5LOZ... 3 sets (single solenoid part number) SX340-5LOZ... sets (double solenoid part number) 35 The " " symbol indicates mounting. Put the " " symbol at the beginning of the part numbers for solenoid valves, etc., which are to be mounted. Valve stations are numbered from station on the D side. Indicate the valves to be mounted below the manifold part number, in order starting from station as shown in the drawing. When a layout becomes complicated, please indicate on a manifold specification sheet.

41 5 Port Solenoid Valve Series SX3000/5000 Manifold Specifications Solenoid Valve Specifications Model Manifold type P (SUP), R (EXH) system Valve stations Note), port piping specifications Port size P, R ports, ports Note ) Valve effective area mm² (Cv factor) Weight W (g) n: Note 3) Location Direction SX3000 SX5000 SX3000 SX5000 SX3000 SX5000 SX3000 SX5000 Flat cable type 45G Plug-in type Common SUP, EXH to 6 stations ase Side C8 (ø8 One-touch fitting) C0 (ø0 One-touch fitting) C4 (ø4 One-touch fitting)/ (ø6 One-touch fitting) C4 (ø4 One-touch fitting)/ (ø6 One-touch fitting) C8 (ø8 One-touch fitting) : P /4.68 (0.6) / R 4.68 (0.6) C8: P /.6 (0.7) / R.6 (0.7) to 0 stations : W = 6n + 7 to 6 stations: W = 6n + 99 to 0 stations : W = 54n + 7 to 6 stations: W = 54n + 64 Note ) vailable with up to 6 solenoids. When a large number of valves will be operated simultaneously, use type (supply/exhaust on both sides), applying pressure to the P ports on both sides and releasing exhaust from the R ports on both sides. Note ) The value is for manifold base mounting (5 stations). position type with single action. Note 3) The weight W is the value for the manifold only. To obtain the weight with solenoid valves, add the solenoid valve weights for the required number of stations. Furthermore, when mounting supply/exhaust block assemblies on both sides of type with a to 0 station manifold, calculate the weight W using the formula for to 6 stations. Series Fluid Internal pilot operating pressure range MPa External pilot operating pressure range MPa position single position double 3 position Operating pressure range Pilot pressure position single position double range 3 position mbient and fluid temperature C Max. operating position single, double frequency Hz 3 position Manual override Pilot Internal pilot exhaust External pilot Lubrication Mounting orientation Impact/Vibration resistance m/s² Note) Enclosure SX3000 SX5000 ir 0.5 to to to kPa to to 0.7 Maximum Non-locking push type, Slotted locking type Main valve, pilot valve common exhaust type Pilot valve individual exhaust type Not required Unrestricted 50/30 Dust proof Note) Impact resistance: No malfunction when tested with a drop tester in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states. Vibration resistance: No malfunction when tested with one sweep of 8.3 to 000Hz in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states. (Initial value) Solenoid Specifications Rated coil voltage llowable voltage fluctuation Power consumption Surge voltage suppressor Indicator light Response Time SX3000 Type of actuation position single position double 3 position SX5000 Type of actuation Weights 4VDC ±0% of rated voltage 0.65W Diode LED Note) ased on JIS dynamic performance test (with coil temperature of 0 C and at rated voltage). position single position double 3 position Response time ms With light/surge voltage suppressor 5 or less 3 or less 0 or less Response time ms With light/surge voltage suppressor 6 or less or less 38 or less Valve model SX340 SX540 Type of actuation Single position Double Closed center 3 position Exhaust center Pressure center Single position Double Closed center 3 position Exhaust center Pressure center Weight g

42 Series SX3000/5000 SX3000: Flat Cable Type/Plug-in SS5X3-45GU- D- C4 Note) L to L4 dimensions of SS5X3-45GU- U- are the same as SS5X3-45GU- D-. L L L3 L SS5X3-45GU- - C4 L L L3 L4 L L L3 L

43 5 Port Solenoid Valve Series SX3000/5000 SS5X3-45GD- - C4 Note) L to L4 dimensions of SS5X3-45GU- U- are the same as SS5X3-45GU- D-. L L L3 L SS5X3-45GD- - C4 L L L3 L4 L L L3 L

44 Series SX3000/5000 SX5000: Flat Cable Type/Plug-in SS5X5-45GU- D- C4 C8 Note) L to L4 dimensions of SS5X5-45GU- U- are the same as SS5X5-45GU- D-. L L L3 L SS5X5-45GU- - C4 C8 39 L L L3 L4 L L L3 L

45 5 Port Solenoid Valve Series SX3000/5000 SS5X5-45GD- U- C4 C8 Note) L to L4 dimensions of SS5X5-45GU- D- are the same as SS5X5-45G- U-. L L L3 L SS5X5-45PD- - C4 C8 L L L3 L4 L L L3 L

46 Please copy this page for use without removing it. SX3000: Flat Cable 0 Pin Type Plug-in Type, DIN Rail Manifold Manifold Valve Specification Sheet Make entries in order from to. How to Order Manifolds Enter the symbols for the required specifications in the blanks below. SS5X3-45G How to Order Valves Enter the symbols for the required specifications in the blanks below. 3 Station Table Indicate the layout of valves, etc., with "X's". (When, port sizes are mixed, indicate the sizes in section (a) with C4 and.) For SMC use only Options When a DIN rail is required that is longer than the standard types, specify the number of stations. (max. 0 stations) Connector mounting direction Symbol Mounting position Supply/Exhaust block U U side assembly specifications D D side Supply/Exhaust block Symbol Valve stations assembly mounting position Nil Symbol Note Mounting R Symbol pplicable stations 0 stations position S U U side RS Double wiring specifications to 0 stations 08 8 stations D D side 0 stations Up to 6 solenoids are possible. oth sides to 6 stations Indicate wiring specifications in M Special specifications 6 6 stations section (e) of the specification table. Indicate special specifications in the station table below. lso includes the number of blanking plate assemblies. SX3 40 Type of actuation position single solenoid position double solenoid 3 3 position closed center 4 3 position exhaust center 5 3 position pressure center a b c d e 5LOZ Make selections in the station table below. Pilot type Valve stations or layout Single solenoid position Double solenoid Closed center 3 position Exhaust center Pressure center lanking plate assembly External pilot specification (enter only in case of external pilot) Enter for Supply/Exhaust block assembly special specs. SUP blocking disk EXH blocking disk ccessories Wiring specifications Nil Internal pilot R External pilot When using an external pilot valve, enter an "X" in the "external pilot specification" section of the station table below. Individual SUP spacer assembly Individual EXH spacer assembly Single wiring Double wiring Notes lanking plate assembly: SX SUP blocking disk: SX EXH blocking disk: SX (pcs./location) 0 Nil D 9 Manual override 8 Non-locking push type Slotted locking type 7 6 Individual SUP spacer assembly: SX Individual EXH spacer assembly: SX Supply/Exhaust block assembly (standard): SX Company name Contact person Specification sheet no. Purchase order no. Equipment name Quantity 4 3 Specifications Standard/Internal pilot specification External pilot specifications Internal pilot/uilt-in silencer External pilot/uilt-in silencer Enter only when wiring specification instructions are necessary for 9 stations or more, and 8 stations or less. Enter the ordered part numbers. 4 Part no. Quantity Part no. 0 9 Quantity 8 7 set(s) Date required 6 5, port size Symbol Specifications C4 ø4 One-touch fitting ø6 One-touch fitting M Mixed Indicate mixed specifications in the station table below. 4 Supply/Exhaust block assembly (R): SX Supply/Exhaust block assembly (S): SX Supply/Exhaust block assembly (RS): SX Order no. Clerk (code no.) Dept. code Date / / Note) When there are special specifications for the mounting position of supply/exhaust block assemblies, enter the part numbers and quantities for supply/exhaust block assemblies together with the manifold model. Quantity

47 Please copy this page for use without removing it. SX5000: Flat Cable 0 Pin Type Plug-in Type, DIN Rail Manifold Manifold Valve Specification Sheet Make entries in order from to. How to Order Manifolds Enter the symbols for the required specifications in the blanks below. SS5X5-45G Symbol How to Order Valves Enter the symbols for the required specifications in the blanks below. SX5 40 Type of actuation position single solenoid position double solenoid 3 3 position closed center 4 3 position exhaust center 5 3 position pressure center Make selections in the station table below. 3 Station Table c d e Connector mounting direction Symbol Mounting position U U side D D side Valve stations Note stations Double wiring specifications 8 stations stations Up to 6 solenoids are possible. Indicate wiring specifications in 6 stations section (e) of the specification table. 6 lso includes the number of blanking plate assemblies. 5LOZ Pilot type Nil R Internal pilot External pilot When using an external pilot valve, enter an "X" in the "external pilot specification" section of the station table below. Supply/Exhaust block assembly mounting position Mounting Symbol position pplicable stations U U side to 0 stations D D side oth sides to 6 stations M Special specifications Indicate special specifications in the station table below. Manual override Nil D Non-locking push type Slotted locking type Company name Contact person Specification sheet no. Purchase order no. Equipment name Quantity Options When a DIN rail is required that is longer than the standard type, specify the number of stations. (max. 0 stations) Supply/Exhaust block assembly specifications Symbol Specifications Nil Standard/Internal pilot specification R External pilot specification S Internal pilot/uilt-in silencer RS External pilot/uilt-in silencer Enter only when wiring specification instructions are necessary for 9 stations or more, and 8 stations or less. set(s) Date required Indicate the layout of valves, etc., with "X's". (When, port sizes are mixed, indicate the sizes in section (a) with C4, and C8.) Valve stations or layout Single solenoid position Double solenoid Closed center 3 position Exhaust center a Pressure center lanking plate assembly External pilot specification (enter only in case of external pilot) b Enter for Supply/exhaust block assembly special specs. SUP blocking disk EXH blocking disk ccessories Wiring specifications Individual SUP spacer assembly Individual EXH spacer assembly Single wiring Double wiring Notes lanking plate assembly: SX SUP blocking disk: SX EXH blocking disk: SX (pcs./location) Enter the ordered part numbers. Part no. Quantity Individual SUP spacer assembly: SX Individual EXH spacer assembly: SX Supply/Exhaust block assembly (standard): SX For SMC use only, port size Symbol Specifications C4 ø4 One-touch fitting ø6 One-touch fitting C8 ø8 One-touch fitting M Mixed Indicate mixed specifications in the station table below. 3 Date / / Quantity Supply/Exhaust block assembly (R): SX Supply/Exhaust block assembly (S): SX Supply/Exhaust block assembly (RS): SX Part no. Quantity Order no. Clerk (code no.) Dept. code Note) When there are special specifications for the mounting position of supply/exhaust block assemblies, enter the part numbers and quantities for the supply/exhaust block assemblies together with the manifold model. 4

48 43

49 Rubber Seal 5 Port Solenoid Valve Series SY3000/5000 Low power consumption: 0.55W (with light) (Current value: 3m, 4VDC) Compact with high flow rate Cv factor.7 to 3 times greater with same body width as previous series High reliability Long life exceeding 50 million cycles Main valve and pilot valve common exhaust construction eliminates pilot valve exhaust mist and noise Type of actuation, port size position 3 position One-touch fitting Series Effective area mm² (Cv factor) Single Double Closed center Exhaust center Pressure center C4 (ø4) (ø6) C8 (ø8) SY (0.6) SY540.6 (0.7) 44

50 Series SY3000/5000 How to Order Manifolds SS5Y 3 45G D 05 U C4 Series 3 SY SY5000 Connector mounting position Symbol Mounting position U U side D D side Symbol 0 stations 6 6 stations Valve stations Note Single wiring specifications (up to 6 solenoids are possible) Two stations are required for double and 3 position (dual body type). lso includes the number of blanking plate assemblies. Options Symbol Mounting position pplicable stations U D U side D side to 0 stations to 0 stations oth sides to 6 stations M Special specifications Indicate special specifications separately on a manifold specification sheet. When a DIN rail is required that is longer than the standard type, specify the number of stations. (max. 0 stations), port size SY3000 SY5000 Symbol Port size Symbol Port size C4 ø4 One-touch fitting C4 ø4 One-touch fitting ø6 One-touch fitting ø6 One-touch fitting M Mixed C8 ø8 One-touch fitting M Mixed Indicate mixed specifications separately on a manifold specification sheet. Supply/Exhaust block assembly specifications Symbol Nil R S RS Specifications Internal pilot specification External pilot specification Internal pilot specification/uilt-in silencer External pilot specification/uilt-in silencer Supply/Exhaust block assembly mounting direction position single Double/3 position 45 How to Order Valves SY FU SY 3 Series 3 SY SY5000 Type of actuation position double 3 3 position closed center 4 3 position exhaust center 5 3 position pressure center Nil R 4 Dual body type (double/3 position) 5 5 FU Pilot type Internal pilot External pilot Rated voltage 5 4VDC Manual override Nil Non-locking push type D Slotted locking type E Knob locking type How to Order Manifold ssemblies Example Single solenoid Supply/Exhaust block SY340-5FU (3 sets) (U side mounting) Double solenoid SY345-5FU ( set) D side U side 3 4VDC +COM + Manifold SS5Y3-45GD-05U- SS5Y3-45GD-05U-... set (manifold part number) SY340-5FU... 3 sets (single solenoid part number) SY345-5FU... set (double solenoid part number) The " " symbol indicates mounting. Put the " " symbol at the beginning of the part numbers for solenoid valves, etc., which are to be mounted. Valve stations are numbered from station on the D side. Indicate the valves to be mounted below the manifold part number, in order starting from station as shown in the drawing. When a layout becomes complicated, please indicate it on a manifold specification sheet. Since double and 3 position (dual body type) valves use two stations on a manifold base, be careful of the number of stations in manifold base part numbers. - SMC

51 5 Port Solenoid Valve Series SY3000/5000 Manifold Specifications Model Manifold type P (SUP), R (EXH) system Valve stations Note), port piping specifications Port size P/R ports / ports Valve effective area mm² (Cv factor) Note ) Note 3) Weight W (g) n: (D-sub connector) Location Direction SY3000 SY5000 SY3000 SY5000 SY3000 SY5000 SY3000 SY5000 Flat cable type 45G Plug-in type Common SUP/EXH to 6 stations ase Side C8 (ø8 One-touch fitting) C0 (ø0 One-touch fitting) C4 (ø4 One-touch fitting)/ (ø6 One-touch fitting) C4 (ø4 One-touch fitting) (ø6 One-touch fitting)/c8 (ø8 One-touch fitting) : P / 4.68 (0.6) / R 4.68 (0.6) C8: P /.6 (0.7) / R.6 (0.7) to 0 stations: W = 6n + 7 to 6 stations: W = 6n + 99 to 0 stations: W = 54n + 7 to 6 stations: W = 54n + 64 Note ) vailable with up to 6 solenoids. When a large number of valves will be operated simultaneously, use type (supply/exhaust on both sides), applying pressure to the P ports on both sides and releasing exhaust from the R ports on both sides. Note ) The value is for manifold base mounting (5 stations). position type with single action. Note 3) The weight W is the value for the manifold only. To obtain the weight with solenoid valves, add the solenoid valve weights for the required number of stations. Furthermore, when mounting supply/exhaust block assemblies on both sides of type with a to 0 station manifold, calculate the weight W using the formula for to 6 stations. Solenoid Valve Specifications Series Fluid Internal pilot operating pressure range MPa External pilot operating pressure range MPa Manual override Pilot exhaust type position single position double 3 position Operating pressure range Pilot pressure range position single position double 3 position mbient and fluid temperature C Max. operating position single, double frequency Hz 3 position Internal pilot External pilot Lubrication Mounting orientation Impact/Vibration resistance m/s² Note) Enclosure Solenoid Specifications SY3000 SY5000 ir 0.5 to to to kPa to to 0.7 Maximum Non-locking push type Slotted locking type, Knob locking type Main valve/pilot valve common exhaust type Pilot valve individual exhaust type Not required Unrestricted 50/30 Dust proof Note) Impact resistance: No malfunction when tested with a drop tester in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states. (Initial value) Vibration resistance:no malfunction when tested with one sweep of 8.3 to 000Hz in the axial direction and at a right angle to the main valve and armature, in both energized and deenergized states. (Initial value) Rated coil voltage llowable voltage fluctuation Power consumption Surge voltage suppressor Indicator light 4VDC ±0% of rated voltage 0.55W Diode LED Response Time Note) ased on JIS dynamic performance test (with coil temperature of 0 C and at rated voltage). SY3000 Type of actuation position single position double 3 position SY5000 Type of actuation position single position double 3 position Weights Response time ms With light/surge voltage suppressor or less 0 or less 6 or less Response time ms With light/surge voltage suppressor 9 or less 8 or less 3 or less Valve model SY340 SY345 SY540 SY545 Type of actuation Single position Double Closed center 3 position Exhaust center Pressure center Single position Double Closed center 3 position Exhaust center Pressure center Weight g

52 Series SY3000/5000 SY3000: Flat Cable Type/Plug-in SS5Y3-45GU- D- C4 Note) L to L4 dimensions of SS5Y3-45GU- C4 U- are the same as SS5Y3 45GU- D-. C4 L L L3 L SS5Y3-45GU- - C4 L L L3 L4 L L L3 L

53 5 Port Solenoid Valve Series SY3000/5000 SS5Y3-45GD- U- C4 Note) L to L4 dimensions of SS5Y3 45GD- D- are the same as SS5Y3 45GD- U-. C4 C4 L L L3 L SS5Y3-45GD- - C4 L L L3 L4 L L L3 L

54 Series SY3000/5000 SY5000: Flat Cable Type/Plug-in SS5Y5-45GU- D- C4 C8 Note) L to L4 dimensions of SS5Y5-45GU- C4 U- are the same as C8 SS5Y5-45GU- D-. C4 C8 L L L3 L SS5Y5-45GU- - C4 C8 L L L3 L4 L L L3 L

55 5 Port Solenoid Valve Series SY3000/5000 SS5Y5-45GD- U- C4 C8 Note) L to L4 dimensions of SS5Y5-45GD- D- C4 C8 are the same as SS5Y5-45GD- U-. C4 C8 L L L3 L SS5Y5-45GD- - C4 C8 L L L3 L4 L L L3 L

56 Please copy this page for use without removing it. SY3000: Flat Cable 0 Pin Type Plug-in Type, DIN Rail Manifold Manifold Valve Specification Sheet Make entries in order from to. How to Order Manifolds Enter the symbols for the required specifications in the blanks below. SS5Y3-45G Connector mounting direction Symbol Mounting position U U side D D side Valve stations Symbol Note 0 6 stations 6 stations Single wiring specifications (up to 6 solenoids are possible.) lso includes the number of blanking plate assemblies. Since valves other than single solenoids are dual body types, they require two stations. How to Order Valves Enter the symbols for the required specifications in the blanks below. SY3 5FU Type of valve actuation ody option 40 position single Standard 45 position double Dual position closed center body position exhaust center type position pressure center Indicate in the station table below. 3 Station Table Supply/Exhaust block assembly specifications Supply/Exhaust block Symbol Specifications assembly mounting position Nil Standard/Internal pilot specification Symbol Mounting R External pilot specification position pplicable stations S Internal pilot/uilt-in silencer U U side to 0 stations RS External pilot/uilt-in silencer D D side oth sides to 6 stations M Special specifications Indicate special specifications, in the station table below. Pilot type Nil D E Non-locking push type Slotted locking type Knob locking type Symbol C4 M Specifications ø4 One-touch fitting ø6 One-touch fitting Mixed Indicate mixed mounting in the station table below by entering C4 and instead of "X's". Note) Connector blocks are not included in stations and layouts. In the case of a single solenoid, enter an "X" in one station box. For double and 3 position, enter an "X" across two station boxes. (Refer to the entry example below.) [When, port sizes are mixed, indicate the sizes in section (a) with C4 and.] Valve stations or layout Quantity Single solenoid position Double solenoid Closed center 3 position Exhaust center Pressure center N.C. single a N.C. double 3 port valve N.O. single N.O. double lanking plate assembly External pilot specification (enter only for external pilot) Refer to the entry example. Enter for Supply/Exhaust block assembly b special specs. SUP blocking disk c EXH blocking disk (pcs./location) [Entry example] Valve stations or layout Single solenoid position a Double solenoid When the port sizes are mixed Enter the ordered part numbers. Part no. 5 Nil Internal pilot R External pilot When using an external pilot valve, enter an "X" in the "external pilot specification" section of the station table below C4 Quantity 3 X X Manual override Company name Contact person Specification sheet no. Purchase order no. Equipment name Quantity set(s) Date required Date / / Options When a DIN rail is required that is longer than the standard type, specify the number of stations. (max. 0 stations), port size Notes lanking plate assembly: SX Supply/Exhaust block assembly (standard): SX SUP blocking disk: SX Supply/Exhaust block assembly (R): SX EXH blocking disk: SX Supply/Exhaust block assembly (S): SX (pcs./location) Supply/Exhaust block assembly (RS): SX For SMC use only Part no. Quantity Order no. Clerk (code no.) Dept. code Note) When there are special specifications for the mounting position of supply/exhaust block assemblies, enter the part numbers and quantities for the supply/exhaust block assemblies together with the manifold model.

57 Please copy this page for use without removing it. SY5000: Flat Cable 0 Pin Type Plug-in Type, DIN Rail Manifold Manifold Valve Specification Sheet Make entries in order from to. How to Order Manifolds Enter the symbols for the required specifications in the blanks below. SS5Y5-45G Connector mounting direction Symbol Mounting position U U side D D side Valve stations Symbol Note 0 stations Single wiring specifications (up to 6 solenoids 6 6 stations are possible.) lso includes the number of blanking plate assemblies. Since valves other than single solenoids are dual body types, they require two stations. How to Order Valves Enter the symbols for the required specifications in the blanks below. SY5 5FU Valve actuation/ody option 40 position single Standard 45 position double Dual position closed center body position exhaust center type position pressure center Indicate in the station table below. 3 Station Table In the case of a single solenoid, enter an "X" in one station box. Note) Connector blocks are not included in stations and layouts. For double and 3 position, enter an "X" across two station boxes. (Refer to the entry example below.) [When, port sizes are mixed, indicate the sizes in section (a) with C4 and.] Valve stations or layout Quantity a b c Single solenoid position Double solenoid Closed center 3 position Exhaust center Pressure center N.C. single 3 port N.C. double valve N.O. single N.O. double lanking plate assembly External pilot specification (enter only for external pilot) Enter for Supply/Exhaust block assembly special specs. SUP blocking disk EXH blocking disk (pcs./location) [Entry example] Valve stations or layout Single solenoid position a Double solenoid When the port sizes are mixed Enter the ordered part numbers. Part no. Supply/Exhaust block assembly mounting position Symbol Mounting position pplicable station U U side to 0 stations D D side oth sides to 6 stations M Special specifications In case of special specifications, indicate in the station table below. Pilot type Nil Internal pilot R External pilot When using an external pilot valve, enter an "X" in the "external pilot specification" section of the station table below. Refer to the entry example C4 Quantity 3 X X Nil D E Company name Contact person Specification sheet no. Purchase order no. Equipment name Quantity Symbol Nil R S RS Manual override Non-locking push type Slotted locking type Knob locking type Options set(s) Date required Date / / When a DIN rail is required that is longer than the standard type, specify the number of stations. (max. 0 stations) Supply/Exhaust block assembly specifications Notes lanking plate assembly: SX SUP blocking disk: SX EXH blocking disk: SX (pcs./location) For SMC use only Part no. Specifications Standard/Internal pilot specification External pilot specification Internal pilot/uilt-in silencer External pilot/uilt-in silencer, port size Symbol Specifications C4 ø4 One-touch fitting ø6 One-touch fitting C8 ø8 One-touch fitting M Mixed Indicate mixed mounting in the station table below by entering C4, and C8 instead of "X's". Supply/Exhaust block assembly (standard): SX Supply/Exhaust block assembly (R): SX Supply/Exhaust block assembly (S): SX Supply/Exhaust block assembly (RS): SX Quantity Order no. Clerk (code no.) Dept. code Note) When there are special specifications for the mounting position of supply/exhaust block assemblies, enter the part numbers and quantities for supply/exhaust block assemblies together with the manifold model. 5

58 53

59 5 Port Solenoid Valve ody Ported Type/Flip Plug-in Unit Series VQ000 Compact manifold for efficient use of space Valves can be replaced without disassembling the entire manifold Seal type allows selection of metal seals or rubber seals Type of actuation Cylinder port size position 3 position One-touch fitting Series Effective area mm² (Cv factor) Single Double Closed center Exhaust center Pressure center C3 (ø3.) C4 (ø4) (ø6) M5 VQ30 Metal seal VQ3 Rubber seal 4.5 (0.5) 6.3 (0.35) 54

60 Series VQ000 How to Order Manifolds VV5Q3 J (-00T) Top entry U0 Side entry S0 Series VQ000 Symbol 0 station 6 6 stations Electrical entry/cable length Kit Flat cable kit (0P) without cable Note ) to 8 (6) Note ) Numbers inside ( ) indicate the maximum number of solenoids for mixed single/double wiring. The maximum number of stations is determined by the total number of solenoids. In case of mixed wiring, add the option symbol "-K". P, R port inch bore size Options Symbol Specifications Nil None D With DIN rail (Rail length: Standard) D With DIN rail (Rail length: Special) Note ) K Special wiring specifications (except double wiring) Note 3) N With name plate S uilt-in silencer & direct exhaust Note ) In case of two or more options, enter them in alphabetical order. Example: DS Note ) Indicate special DIN rail length as "D" ( indicates stations) Example: D08 In this case, an eight station DIN rail will be provided regardless of the number of manifold stations. Indicate "-D0" for no DIN rail. Note 3) e sure to indicate wiring specifications on a manifold specification sheet. VQ 3 5 Series VQ000 Type of actuation Symbol Type of actuation position double position double (latching) 3 Note) 3 position closed center 4 Note) 3 position exhaust center 5 Note) 3 position pressure center Note) The 3 position type uses two stations. Symbol Nil H Note ) Y Note ) Symbol 0 Seal type Seal type Metal seal Rubber seal Function Specifications Standard type (W) High pressure type (.5W) Low power consumption type (0.5W) Note ) When specifying two or more options, enter symbols in alphabetical order. Note ) Except double (latching) type How to Order Valves Symbol Nil P R Symbol C3 C4 M5 Options (with blocking valve & port plug) Specifications None With SUP blocking plate With EXH blocking plate With SUP/EXH PR blocking plate Port plug ( port) Port plug ( port) Note) Since blocking plates are built into valves, add the above option symbols when required. Cylinder port size Port size One-touch fitting for ø3. One-touch fitting for ø4 One-touch fitting for ø6 M5 threads Note) Inch sizes use the following symbols. N: ø/8 N3: ø5/3 N7: ø/4 How to Order Manifold ssemblies Enter part numbers for valves and options to be mounted below the manifold base part number. <Example> Flat cable kit VV5Q3-08JUO set Manifold base part number VQ sets Valve part number ( to 4) VQ sets Valve part number ( 5 to 8) dd the " " symbol at the beginning of part numbers for solenoid valves, etc., to be mounted. D side U side 3 Enter in order starting from the first station on the D side. When entry of part numbers becomes complicated, indicate them on a manifold specification sheet. Rated voltage 5 4VDC Manual override Symbol Manual override Non-locking push type Nil (tool required) Slotted locking type (tool required) C Knob locking type (manual type) 55

61 5 Port Solenoid Valve Series VQ000 Models Manifold Specifications SeriesNumber Number of of solenoids Model Series solenoids Model VQ000 3 position position Standard Specifications Note ) Note ) Note ) ) Response Response time time ms Effective area ms area mmmm² ( Cv Standard: factor) dard:wlow power (Cv factor) H: 5W and C Metal seal VQ (0.5) or less 5 or less Single Rubber seal VQ3 6.3 (0.35) 5 or less 0 or less 57 Double Metal seal VQ (0.5) or less 5 or less (latching) Rubber seal VQ3 6.3 (0.35) 5 or less 0 or less Closed Metal seal VQ (0.5) 0 or less 6 or less center Rubber seal VQ (0.35) 5 or less 33 or less Exhaust Metal seal VQ (0.5) 0 or less 6 or less center 0 Rubber seal VQ (0.35) 5 or less 33 or less Pressure Metal seal VQ (0.5) 0 or less 6 or less center Rubber seal VQ (0.35) 5 or less 33 or less Note ) Values are for cylinder port size. Note ) ased on JIS (Values for supply pressure of 0.5MPa with light/surge voltage suppressor using clean air. This will change depending on pressure and air quality.) Weight g Series ase model VQ000 VV5Q3- Side Piping specifications Port location Port size P, R, (for ø6) Options: uilt-in silencer Direct exhaust C3 (for ø3.) C4 (for ø4) (for ø6) M5 (M5 thread) pplicable stations to 6 stations pplicable solenoid valves 5 station weight g VQ 30 VQ 3 44 Valve specifications Electrical specifications Valve construction Fluid Max. operating pressure Minimum operating pressure mbient and fluid temperature Lubrication Single Double (latching) 3 position Manual override Note ) Impact/Vibration resistance Enclosure Rated coil voltage llowable voltage fluctuation Coil insulation type Power consumption (current value) 4VDC Metal seal Rubber seal ir, Inert gas ir, Inert gas 0.7MPa (High pressure type: 0.8MPa) 0.MPa 0.8MPa 0.MPa 0 to 50 C Note ) 0.5MPa 0.8MPa 0.MPa Not required Push type/locking type (slotted type, knob type) optional 50/30m/s² Dust proof 4VDC ±0% of rated voltage Class equivalent DCW (4m), DC.5W (63m), Note 3) 0.5W (m) Note 4) Note ) In case of low temperature, use dry air with no condensation. Note ) Impact resistance... No malfunction when tested with a drop and impact tester in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states. (Initial value) Vibration resistance No malfunction when tested with one sweep of 8.3 to 000Hz in the axial direction and at a right angle to the main valve and armature, in both energized and deenergized states. (Initial value) Note 3) Value for high pressure type (.5W) specification Note 4) Value for the low power consumption (0.5W) specification 56

62 Series VQ000 VQ000/Flat Cable Kit U VV5Q3- J S0- (D) pplicable connector: Flat cable connector (0P) (conforms to MIL-C-83503) 4 35 () 9.5 (Mounting hole dimension) L L 6. P = 3..5 Indicator light Manual override -M4 mounting hole R (5.5) (35) = 4.5 (L3) (5.) (L4) - P(SUP) port D side n U side P P R R () R(EXH) port P = 7 9. (7.5) n-c3, C4,, M5 C3: One-touch fitting for ø3. C4: One-touch fitting for ø4 : One-touch fitting for ø6 M5: M5 threads roken lines indicate DIN rail mount type [-D] and connector top entry [-JU]. Note) The 3 position type uses two stations. Cylinder ports are located on the U side of the body between two stations. Dimensions Formulae L = n n L L L (L3 ) (L4 ) L = n + 55 n: (max. 6 stations)

63 58

64 Manifold Specification Sheet Series VQ000/Flip, Plug-in Unit. How to Order Manifolds VV5Q 3 08 J U0 N ( 00T ) Series VQ000 Flip, Plug-in Kit designation 3 For P, R port inch sizes 0 station 3 6 Nil D D K N S 6 stations Options Electrical entry/cable length Top entry Side entry None With DIN rail (Rail length: Standard) With DIN rail (Rail length: Special) Note ) Special wiring specifications (except double wiring) Note 3) With name plate uilt-in silencer, Direct exhaust Note ) U0 S0 Flat cable kit (0P) Without cable to 8 (6) Note ) Numbers inside ( ) indicate the maximum number of solenoids for mixed single/double wiring. The maximum number of stations is determined by the total number of solenoids. In case of mixed wiring, add the option symbol "-K". Note ) When specifying more than one option, enter symbols in alphabetical order. Example) -DS Note ) Indicate special DIN rail length as D ( indicates stations). Example: -D08 In this case, an eight station DIN rail will be provided regardless of the number of manifold stations. Indicate "-D0" for no DIN rail. Note 3) e sure to indicate wiring specifications on a specification sheet. Kit, Cable length U side n D side Note) are counted starting from station on the D side.. How to Order pplicable Valves VQ 3 0 Y 5 C C4 Series VQ000 C D E F Type of actuation 3 Note) 4 Note) 5 Note) position single position double (latching) 3 position closed center 3 position exhaust center 3 position pressure center Note) The 3 position type uses two stations. Seal type 0 Metal seal Rubber seal C Function Symbol Specifications DC Nil Standard type (.0W) H Note ) High pressure type (.5W) Y Note ) Low power consumption type (0.5W) Note ) Except double (latching) type Note ) When specifying more than one option, enter symbols in alphabetical order. D Manual operation Nil Non-locking push type (tool required) Slotted locking type (tool required) C Knob locking type (manual type) E Cylinder port size C3 C4 M5 With One-touch fitting for ø3. With One-touch fitting for ø4 With One-touch fitting for ø6 M5 threads Note) Inch sizes use the following symbols. N: ø/8 N3: ø5/3 N7: ø/4 F Options (blocking valve & port plug) Nil None P With SUP blocking plate R With EXH blocking plate PR With SUP and EXH blocking plates Port plug Port plug Note) Since blocking plates are built into valves, add the above option symbols when required. 59

65 Manifold Specification Sheet Series VQ000/Flip, Plug-in Unit How to Order Manifolds VV5Q Series VQ000 3 J ( 00T) Flip, Plug-in For P, R port inch sizes Kit designation Company name Contact person Specification sheet no. Purchase order no. Equipment name Quantity Date / / set(s) Required date Specifications Description/Model D side U side Enter an "X" in the required locations. Station Valves Single Metal seal Double (latching) Closed center (uses two stations) Exhaust center (uses two stations) Pressure center (uses two stations) Rubber seal Options lanking plate VVQ Individual SUP spacer Note ) VVQ000-P-3- SUP shut-off position: Indicate one location. Individual EXH spacer Note ) VVQ000-R-3- EXH shut-off position: Indicate one location. SUP shut-off position Note ) (for blocking valve) EXH shut-off position Note ) (for blocking valve) Cylinder port size Enter in case of mixed sizes (CM). Port plug Note 3) With One-touch fitting for ø3. (ø/8 ) With One-touch fitting for ø4 (ø5/3 ) With One-touch fitting for ø6 (ø/4 ) M5 threads Side C3 ported (N) Side C4 ported (N3) Side ported (N7) Side ported M5 Special wiring specifications Note 4) Description/Model Single wiring Double wiring Station Notes Note ) For individual SUP and EXH spacers, the D side of the SUP and EXH passages are shut off. Indicate one more shut-off position. Note ) locking plates are built into valves. Indicate shut-off positions in the table above. (The D sides of the SUP and EXH passages are shut off.) Note 3) When using port plugs, circle the specified ports. Note 4) In case of single wiring or mixed wiring, connections to the connector terminals start from the side solenoid of station and continue in order without skipping any terminals. pplicable valves and options Part no. Qty. Part no. Qty. Order no. Clerk (code no.) Dept. code Copy this page for use as needed. 60

66 6

67 5 Port Solenoid Valve ase Mounted Type/Plug-in Unit Series VQ000/000 Space saving design locates all pilot valves on one side One-clamp construction with no screws allows easy valve replacement variety of options ack pressure check valve, uilt-in silencer, Name plate, etc. Seal type allows selection of metal seals or rubber seals Effective area mm² (Cv factor) Type of actuation position 3 position Cylinder port size One-touch fitting Series position 3 position Single Double Closed center Exhaust center Pressure center C3 (3.) C4 (ø4) (ø6) C8 (ø8) M5 VQ00 Metal seal VQ0 Rubber seal VQ00 Metal seal VQ0 Rubber seal 3.6 (0.) 5.4 (0.3) 4.4 (0.8) 6. (0.9) 3.6 (0.) 5.4 (0.3).6 (0.7) 4.4 (0.8) 6

68 Series VQ000/000 VQ000 Symbol Port size C3 With One-touch fitting for ø3. C4 With One-touch fitting for ø4 With One-touch fitting for ø6 M5 M5 threads CM Mixed and with port plug L3 Elbow top ported With One-touch fitting for ø3. L4 Elbow top ported With One-touch fitting for ø4 L6 Elbow top ported With One-touch fitting for ø6 L5 Elbow top ported M5 threads 3 Elbow bottom ported With One-touch fitting for ø3. Elbow bottom ported 4 With One-touch fitting for ø4 Elbow bottom ported 6 With One-touch fitting for ø6 Elbow bottom ported 5 M5 threads LM Elbow mixed port sizes Symbol How to Order Valves VQ 0 0 Y 5 Series Symbol VQ000 VQ000 Type of actuation Type of actuation position double position double 3 position closed center 3 position exhaust center 3 position pressure center Symbol 0 Series Symbol VQ000 VQ000 Seal type Seal type Metal seal Rubber seal Function Symbol Nil H R Y How to Order Manifolds VV5Q 08 GU0 Symbol 0 stations 6 6 stations Cylinder port size VQ000 Symbol Port size C4 With One-touch fitting for ø4 With One-touch fitting for ø6 C8 With One-touch fitting for ø8 CM Mixed and with port plug L4 Elbow top ported With One-touch fitting for ø4 L6 Elbow top ported With One-touch fitting for ø6 L8 Elbow top ported With One-touch fitting for ø8 4 Elbow bottom ported With One-touch fitting for ø4 6 Elbow bottom ported With One-touch fitting for ø6 8 Elbow bottom ported With One-touch fitting for ø8 LM Elbow mixed port sizes Note ) For CM and LM, indicate in the specification table. Note ) Inch sizes use the following symbols. VQ000 VQ000 N: ø/8" N3: ø5/3" N3: ø5/3" N7: ø/4" N7: ø/4" N9: ø5/6" N5T: 0-3UNF NM: Mixed NM: Mixed Top ported elbows are LN and bottom ported elbows are N. 63 Symbol Nil Manual override Symbol Manual override Non-locking push type Nil (tool required) C Function Standard type (W) High pressure type (.5W) External pilot Low power consumption type (0.5W) Note ) When specifying two or more, list them in alphabetical order. J kit G kit Slotted locking type Knob locking type Options VQ000 specifications None ack pressure check valve on all stations Note ) With DIN rail (Rail length: Standard) With DIN rail (Rail length: Special) Note 3) JU0 G0 (VQ000) GU0 (VQ000) JS0 Symbol Nil Kit Flat cable kit (0P) without cable Flat cable kit (0P) with terminal block without cable VQ000 specifications None D D D D ack pressure check valve on all stations Note ) With DIN rail (Rail length: Standard) With DIN rail (Rail length: Special) Note 3) G Regulator unit with unit Note 4) Special wiring specifications K G Regulator unit with units Note 4) (except double wiring) Note 6) G3 J Regulator unit with 3 units Note 4) With ejector unit Note 5) N R With name plate External pilot Note 7) K N R S With name plate External pilot Note 7) uilt-in silencer, Direct exhaust Special wiring specifications S uilt-in silencer, Direct exhaust (except double wiring) Note 6) Note ) In case of two or more options, enter them in alphabetical order. Example) -RS Note ) When using back pressure check valves only on required stations, enter the back pressure check valve part numbers and indicate the stations for mounting in the specification table. Note 3) Indicate a special DIN rail length as D ( indicates stations). Example) -D08 In this case, an eight station DIN rail will be provided regardless of the number of manifold stations. Indicate "-D0" for no DIN rail. Note 4) Indicate regulator unit mounting stations in the specification table. Count as unit, station. Note 5) Refer to the separate catalog CT.E38- for details when equipped with ejector unit. lso, "-J" and name plate "-N" cannot be combined. Note 6) e sure to indicate wiring specifications in the manifold specification table. Note 7) In case of an external pilot "R", indicate external pilot specifications "R" for the applicable valve also. Electrical entry Top entry Side entry Note) to 8 (6) to 8 (6) Note ) Numbers inside ( ) indicate the maximum number of solenoids for mixed single/double wiring. The maximum number of stations is determined by the total number of solenoids. In case of mixed wiring, add the option symbol "-K". How to Order Manifold ssemblies Enter part numbers for valves and options to be mounted below the manifold base part number. <Example> Flat cable kit with terminal block VV5Q-08G0... set Manifold base part number VQ sets Valve part number (stations to 4) VQ set Valve part number (station 5) VQ sets Valve part number (stations 6 to 8) dd the " " symbol at the beginning of part numbers for solenoid valves, etc., to be mounted. U side D side 3 Enter in order starting from the first station on the D side. When entry of part numbers becomes complicated, indicate them on a manifold specification sheet.

69 5 Port Solenoid Valve Series VQ000/000 Models Manifold Specifications Series Single Metal seal VQ (0.) or less 5 or less Rubber seal VQ0 5.4 (0.3) 5 or less 0 or less 64 Double Metal seal VQ (0.) 0 or less 3 or less Rubber seal VQ0 5.4 (0.3) 5 or less 0 or less Closed Metal seal VQ (0.) 0 or less 6 or less center Rubber seal VQ (0.3) 5 or less 33 or less 78 Exhaust Metal seal VQ (0.) 0 or less 6 or less center Rubber seal VQ (0.3) 5 or less 33 or less Pressure Metal seal VQ (0.) 0 or less 6 or less center Rubber seal VQ (0.3) 5 or less 33 or less Single Metal seal VQ (0.8) or less 9 or less Rubber seal VQ0 6. (0.9) 4 or less 3 or less 90 Double Metal seal VQ (0.8) 5 or less 0 or less Rubber seal VQ0 6. (0.9) 0 or less 6 or less Closed Metal seal VQ300.6 (0.7) 9 or less 38 or less center Rubber seal VQ (0.8) 34 or less 44 or less 0 Exhaust Metal seal VQ400.6 (0.7) 9 or less 38 or less center Rubber seal VQ (0.8) 34 or less 44 or less Pressure Metal seal VQ500.6 (0.7) 9 or less 38 or less center Rubber seal VQ (0.8) 34 or less 44 or less Note ) Values are for cylinder port sizes (VQ000) and C8 (VQ000) without back pressure check valve. Note ) ased on JIS (Values for supply pressure of 0.5MPa with light/surge voltage suppressor, using clean air. This will change depending on pressure and air quality.) Value for the double type when ON. VQ000 VQ000 position 3 position position 3 position Number of solenoids Model Note ) Effective area mm² (Cv factor) Response time ms Standard: W H: 5W Note ) Low power Weight g Series VQ000 VQ000 ase model VV5Q- VV5Q- Piping direction Side Side Piping specifications Port size Note ) P, R, C8 (for ø8) C3 (for ø3.) Options: C4 (for ø4) uilt-in silencer (for ø6) Direct exhaust M5 (M5 threads) C0 (for ø0) C4 (for ø4) Options: (for ø6) uilt-in silencer Direct exhaust C8 (for ø8) pplicable stations to 6 stations to 6 stations pplicable solenoid valves VQ00 VQ0 5 station weight g 68 (single) 759 (double, 3P) 05 VQ00 (single) VQ0 44 (double, 3P) Standard Specifications Valve specifications Electrical specifications Valve construction Fluid Max. operating pressure Single Minimum operating Double pressure 3 position mbient and fluid temperature Lubrication Manual override Note ) Impact/Vibration resistance Enclosure Rated coil voltage llowable voltage fluctuation Coil insulation type Power consumption (current value) 4VDC Metal seal ir, Inert gas 0.MPa 0.MPa 0.MPa Rubber seal ir, Inert gas 0.7MPa (High pressure type: 0.8MPa) 0 to 50 C Note ) 0.5MPa 0.MPa 0.MPa Not required Push type/locking type (slotted type, knob type) optional 50/30m/s² Dust proof 4VDC ±0% of rated voltage Class equivalent DCW (4m), DC.5W (63m), Note 3) DC0.5W (m) Note 4) Note ) In case of low temperature, use dry air with no condensation. Note ) Impact resistance... No malfunction when tested with a drop and impact tester in the axial direction and at a right angle to the main valve and armature, one time in both energized and deenergized states. (Initial value) Vibration resistance No malfunction when tested with one sweep of 8.3 to 000Hz in the axial direction and at a right angle to the main valve and armature, in both energized deenergized states. (Initial value) Note 3) Value for high pressure type (.5W) specifications Note 4) Value for low power consumption (0.5W) specifications 64

70 Series VQ000/000 VQ000/Flat Cable Kit with Terminal lock VV5Q- G0-(D) roken lines and dimensions inside ( ) indicate type [-D] (with DIN rail mounting bracket). Dimensions Fomulae L = 0.5n n L L L (L3) (L4) L = 0.5n + 63 n: (max. 6 stations)

71 5 Port Solenoid Valve Series VQ000/000 VQ000/Flat Cable Kit with Terminal lock VV5Q- GU0-(D) roken lines and dimensions inside ( ) indicate type [-D] (with DIN rail mounting bracket). Dimensions Formulae L = 6n + 53 n L L L (L3) (L4) L = 6n + 87 n: (max. 6 stations)

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),

More information

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector

More information

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications Series -SQ00 Port Solenoid Valve Plug-in Unit [Option] How to Order Manifold Electrical entry F kit D-sub connector kit P kit SSQ 08 FD Kit type Flat ribbon cable connector kit J kit Flat ribbon cable

More information

VQ1000. How to Order Manifold. Kit type

VQ1000. How to Order Manifold. Kit type - - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold

More information

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000 D-sub Connector J Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000//000 Number of connectors: pins MIL-C-08 Conforming to JIS-X-0 --6 For details

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 0 PW COM Rubber Seal Port Solenoid Valve Series SZ000 Cassette Type Manifold The plug-in cassette system makes valve replacement easy. plug-in manifold has been created with a height of. mm (including

More information

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve CT.E- ase Mounted Type Series VQ Port Metal Seal/Rubber Seal Solenoid Valve dvanced manifold va the new age of factory au ase Mounted Type Space saving profile Clean space saving design with all pilot

More information

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000

More information

Fieldbus System (Output device for driving 5 port solenoid valves)

Fieldbus System (Output device for driving 5 port solenoid valves) Fieldbus System (Output device for driving port solenoid valves) New Compact 8mm (ctual size) Space-saving Installation IP67 RoHS EtherNet/IP added! For units with D-sub connector, and when connected to

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Series VQ Rubber Seal Space-saving profile Clean space saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

How to Order Manifold. Kit type L8 B4 B6 B8 LM

How to Order Manifold. Kit type L8 B4 B6 B8 LM 0 Stations station VVQ Series VQ000 The maximum and minimum number of are varied depending on. (Refer to the table below.) Series VQ000 ase Mounted Plug-in Unit Manifold Plug-in unit 08 C Cylinder port

More information

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position

More information

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308 Cable ppendix Cable ppendix Multi-way cables The multi-pole connector cables used on SMC valves are common across several ranges. Cables are available in accordance with the MIL standard C-08 and also

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type20P 5 Port Solenoid Valve ody Ported Manifold ar Stock Type/Flat Ribbon Cable Series SY3000/5000/7000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 5 20P 05 Manifold series 3 SY3000

More information

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring Type4 SY000/000 ase Mounted Monifold Stacking Type/DIN ail Mounted Individual Wiring How to Order Manifold SSY 4 0 U C6 How to Order Valve Manifold ssembly Ordering example SY000 SY000 Valve stations 02

More information

Gateway Type Serial Transmission System

Gateway Type Serial Transmission System P99-EX-B Gateway Type Serial Transmission System P Maximum 8 point control (64 inputs/64 outputs) P Flexibility of manifold valve installation improved with 4 branch wiring Flexible installation and removal

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Rubber Seal Series VQ Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

More information

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type1P Type2P 5 Port Solenoid Valve ase Mounted Manifold ar Stock Type/Flat Ribbon Cable Series /5000/000 How to Order Manifold Type 1P/Compact style SS5Y 5 1P 05 C8 Manifold series 3 5, port size Thread

More information

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection Rubber Seal Port Solenoid Valve Series SJ000/000 Cassette Type Manifold 0 mm 7. mm (SJ000) 0 mm (SJ000) Non plug-in type Individual wiring manifold SJ000 SJ000 Can be mounted together. Connecter connection

More information

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Port Solenoid Valve Metal Seal Rubber Seal Series Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

Series VQZ1000/2000/3000 Single Unit

Series VQZ1000/2000/3000 Single Unit +- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body

More information

Fieldbus System (Gateway Decentralized Type)

Fieldbus System (Gateway Decentralized Type) Fieldbus System (Gateway Decentralized Type) * * Except the SY, VQC and S0700 valves GW Unit which supports PROFINET added. New M connector type Input Unit added. Decentralized valve installation Valves

More information

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer Base Mounted Metal Seal/Rubber Seal VQ Built-in silencer, direct exhaust Space-saving profile All pilot valves are compactly mounted on one side. The space-saving design of mounting all fittings on one

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series

More information

New Concept Connector Type Manifold

New Concept Connector Type Manifold New Concept Connector Type Manifold Series /000/3000/000 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration.

More information

Series SY3000/5000 How to Order Manifold

Series SY3000/5000 How to Order Manifold Type N ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN Rail Mounted/Connector ox SY/ How to Order Manifold SSY SY SY Specifications Symbol Specifications With connector box (COM spec.) N With

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

CAT.E152-5 Port Solenoid Valve/Body Ported Cassette Type Manifold. Series SZ3000

CAT.E152-5 Port Solenoid Valve/Body Ported Cassette Type Manifold. Series SZ3000 CAT.E- Port Solenoid Valve/Body Ported Cassette Type Manifold Series SZ000 The plug-in cassette system makes valve replacement easy. A plug-in manifold has been realized having a manifold height of.mm

More information

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1 Port Solenoid Valve Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Non plug-in manifold 0 0 S 60 Stations stations 0 stations SUP/EXH

More information

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating / ort Solenoid Valve ubber Seal Series SYJ000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Specifications JIS Symbol port port (manifold) position

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

Series SV1000/2000/3000/4000

Series SV1000/2000/3000/4000 Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double

More information

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A Type N SY/ ase ounted anifold Stacking Type/DIN Rail ounted Connector ox How to Order anifold SSY SY SY Specifications Symbol Specifications With connector box (CO spec.) N With connector box ( CO spec.)

More information

Example. U side. Stations SY5000

Example. U side. Stations SY5000 45 Type 5 ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN ail Mounted/Individual Wiring Series SY3000/5000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 3 45 05 U C6 Example

More information

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal Port Solenoid Valve Cassette Type Manifold Rubber Seal 7.mm (SJ000) SJ000 SJ000 Can be mounted together. 0mm (SJ000) Connector connection New New cable type manifold is added! New Additional options are

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to

More information

0.35 W (Without light)

0.35 W (Without light) Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and

More information

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing

More information

Plug Lead Unit: Flip Type

Plug Lead Unit: Flip Type Series ody orted lug Lead Unit: Flip Type For details about certified products conforming to international standards, visit us at www.smcworld.com. 0 Series Kit/Electrical entry/cable length F kit (D-sub

More information

2.26 S OLENOID VALVES S ERIES VQ1000

2.26 S OLENOID VALVES S ERIES VQ1000 2.26 S OLENOID VALVES 5 PORT M ETAL S EAL/RUBBER S EAL U LTRA H IGH S PEED S OLENOID VALVE High Speed Response from new Solenoid Design. Long Life: Over 200 Million Cycles can be with Patent Pilot Valve

More information

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I ISO Standard Solenoid Valve Series VQ7-6/7-8 (Size ) (Size ) Conforms to ISO Standard /I.0- Ideal for driving cylinders up to Large flow capacity ø00 (VQ7-6, Size ) ø60 (VQ7-8, Size ) Nl/min VQ7-6: 668.

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot ubber seal ort ilot Solenoid Valve Series SYJ00 Specifications efer to www.smcworld.com for details of products compatible with overseas standards. Body ported Base mounted Fluid Operating pressure range

More information

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle. Multistage Ejector 112/212 Series Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

5 Port Solenoid Valve Plug Lead Type

5 Port Solenoid Valve Plug Lead Type 5 Port Solenoid alve Plug Lead Type Series Body Ported Flow rate characteristics For single/double solenoid C [dm 3 /(s bar)]: 0.6 Single Unit alve width: 7.4 mm Possible to drive cylinders: Up to ø32

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve ubber Seal / ort Solenoid Valve Series 000 / 000 / 000 [Option] SJ SY SV SZ V S000 VQ VQ VQ VQC VQZ SQ VFS VF VQ Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

High Pressure Coolant Valve

High Pressure Coolant Valve High Pressure Coolant Valve Series.5 MPa, 7.0 MPa Corresponding to high speed grinding and long drilling processes Coolant valve for high pressure coolant liquid (up to.5 MPa or 7.0 MPa) that is ideal

More information

Terminal Block Box (Spring Type) SY3000/5000/7000 Series

Terminal Block Box (Spring Type) SY3000/5000/7000 Series INFORMATION 5 ort olenoid alve Terminal lock ox (pring Type) Y3000/5000/7000 eries Compact RoH Height 6.7 mm shorter (Approx. 9% reduction) Installation area of the terminal block box Reduced by approx.

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M. V3 Cover

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve CT.ES8 / ort Solenoid Valve Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M.7 to M2. 앬 Flow Characteristics Series Cover (stainless

More information

3MA0/3MB0. Small pneumatic valve. 3 port direct acting valve CONTENTS. Space saving Valves are compactly designed with widths of 10 mm

3MA0/3MB0. Small pneumatic valve. 3 port direct acting valve CONTENTS. Space saving Valves are compactly designed with widths of 10 mm M0/MB0 Small pneumatic valve M Overview The M0 and MB0 Series port valve is a 0 mm wide miniature direct-acting poppet valve compatible with system downsizing. variety of types, including discrete and

More information

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000) 5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust

More information

3 Port Solenoid Valve

3 Port Solenoid Valve 3 ort Solenoid Valve Series VKF300 ubber Seal Direct Operated oppet Type Compact yet provides a large flow capacity Body width 8 mm vailable in vacuum applications ( 0. ka) Can be used in vacuum/release

More information

How to Order Manifold. Option Symbol

How to Order Manifold. Option Symbol Series Plug Lead nit For details about certified products conforming to international standards, visit us at www.smcworld.com. Series/Manifold 12 Stations 01 1 station Kit/Electrical entry/cable length

More information

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A) ort Solenoid Valve ubber Seal Series SY00 Low power consumption: 0.W (Standard, Without light) (Current draw: m at V DC) Large flow capacity style:0.7w (Current draw: m at V DC) Body width: 0mm 7.8 Nl/min

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

Series SYJ300/500/700

Series SYJ300/500/700 ort Solenoid Valve ubber Seal Series SYJ00/00/00 Low power consumption: 0.W (Without light) (Current draw: 1m at 4V DC) Completely interchangeable ilot exhaust with the previous series VJ00/00/00 and VZ00/00.

More information

Base Mounted Plug-in/Plug Lead: Single Unit

Base Mounted Plug-in/Plug Lead: Single Unit ase mounted VQ ase Mounted lug-in/lug Lead: Single Unit Model Number of solenoids Model Single Metal seal VQ Rubber seal VQ ouble Metal seal VQ Rubber seal VQ Closed Metal seal VQ VQ center Rubber seal

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles ort Solenoid Valve: ase Mounted Metal Seal/Rubber Seal Series Space and capacity saving ilot valve is gathered at one side. Space saving design which does not have any protrusions. Space saving Capacity

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position

More information

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Vacuum Release Valve with Restrictor Series SJ3A6 SJ Plug-in Type Connector Connection P.86 D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Non Plug-in Type Individual

More information

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Body Ported Base Mounted Series S000 S000 S000 S000 S000 S4000 S5000 Sonic conductance C [dm /s bar)] 4/ 5/(A/B R/R) Single Double.8.4

More information

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type. Series -S00 ompact Direct Operated Port Solenoid Valve ontrol Valves ase mounted ody ported lean Series lean Series V S R oil voltage 24 VD VD VD VD VD Power consumption Pressure specification Flow rate

More information

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit CT.EUS8 UK ower Consumption / ort Solenoid Valve With ower Saving Circuit Series SYJ000/000/7000 Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3

More information

Rubber Seal VP300/500/700

Rubber Seal VP300/500/700 Port Pilot Operated Poppet Rubber Seal 00/500/700 High flow capacity Cv1.0 (00), Cv. (500), Cv.0 (700) Low power consumption: 1.8W(DC) Possible to use as either selector valve or divider valve Changeable

More information

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is. Port Solenoid Valve Series VQ 00 Unprecedented high speed, stable response, and extra-long service life. ON:.ms, OFF: ms, Dispension accuracy ±ms (With indicator light and surge voltage suppressor; supply

More information

3, 5 port pilot operated valve Pneumatic valve / master valve. Discrete valve. Manifold

3, 5 port pilot operated valve Pneumatic valve / master valve. Discrete valve. Manifold K/K, pilot operated valve neumatic valve / master valve MNE0 MNE0 M MN W WG MNS0 MNS0 T L-/ S/0 S/ K/ F CONTENTS Safety precautions 776 Discrete valve ody ing (K/K to ) 868 Sub-plate ing (K to ) 87 Manifold

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 044 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000 racket

More information

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC Base Mounted Series VQZ00/00/00 VQZ00/00 / How to Order Valve Made to Order (For details, refer to page 9 and 4.) VQZ 5 5 M Series VQZ00 body width 5 mm VQZ00 body width 8 mm Type of actuation 4 N.C. N.O.

More information

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold Port Solenoid Valve VV00 Series Highly Integrated Unit Manifold po ted - pera irect-o d station es on rt valv ally ividu Ind wired n be ve ca val d. adde ector Con-inn connection) lug (For p ø connection

More information

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types Speed 2 Port Valve Series RoHS speed speed speed response response response 5 ms 9mm Width ±0.05 ms ±0.05 ms type VCH : : 5 ms * The response time is measured based on SMC test conditions. (Not guaranteed

More information

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles Port Solenoid Valve: ase Mounted Metal Seal/Rubber Seal Series VQ Space and capacity saving Pilot valve is gathered at one side. Space saving design which does not have any protrusions. Space saving Capacity

More information

3 Port 3 Position Valve

3 Port 3 Position Valve Port Position Valve Pilot Solenoid ir Operated ohs Intermediate stopping of cylinders * up to ø15 is possible. Pilot solenoid Manifold ir operated * For VEX 4, 00 mm/s, horizontal movement Power consumption:

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry TEX Compliant Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 44 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid alve Plug Lead Type RoHS New Body Ported Flow-rate characteristics For single/double solenoid C [dm 3 /(s bar)]: 0.6 Single Unit alve width: 7. mm Possible to drive cylinders: Up to ø32

More information