VQ1000. How to Order Manifold. Kit type

Size: px
Start display at page:

Download "VQ1000. How to Order Manifold. Kit type"

Transcription

1 - - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 J kit (Flat ribbon cable) VQ000/000 F kit (D-sub connector) -VQ000/000 kit (Flat ribbon cable) - -VQ000/000 G kit (Flat ribbon cable with terminal block) -VQ000/000 T kit (Terminal block box) -VQ000/000 L kit (Lead wire) -VQ000/000 S kit (Serial transmission) EX0 -VQ000/000 S kit (Serial transmission) EX0// -VQ000 M kit (Circular connector) /-VQ000 lug-in /-VQ000 VQ000 Sub-plate Single Unit VQ000/000 Semi-standard VQ000/000 Construction VQ000/000 Exploded View of Manifold VQ000/000 Manifold Optional arts VQ000/000 Specific roduct recautions Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control Flow Control ressure Switches/ ressure Sensors

2 - VQ000 ase Mounted lug-in Unit Note) For models, DC-type only. [Option] 0 0 Clean series Copper/Fluorine/Silicone free + Low particle generation Cylinder port VVQ VQ000 Manifold lug-in unit 0 station 08 C The number of max. stations differs from kit to kit. (efer to the table below.) How to Order Manifold Symbol ort size Symbol ort size C C C M With ø. One-touch fitting With ø One-touch fitting With ø One-touch fitting M thread L CM Note ) Mixed sizes and with port plug L L L Top ported elbow with ø. One-touch fitting Top ported elbow with ø One-touch fitting Top ported elbow with ø One-touch fitting LM Note ) MM Note ) Top ported elbow M thread ottom ported elbow with ø. One-touch fitting ottom ported elbow with ø One-touch fitting ottom ported elbow with ø One-touch fitting ottom ported elbow M thread Elbow port, mixed sizes Mixed size for different types of piping, option installed Note ) Indicate Mixed sizes and with port plug by means of the manifold specification sheet. Note ) When selecting the mixed size for different types of piping or dual flow fitting assembly, enter MM and give instructions on the manifold specification sheet. Note ) Inch-size One-touch fittings are also available. efer to page for details. Note ) M fittings for M thread are attached without being incorporated. F U Kit type Q Note) For models, DC-type only. Option Symbol Option 00/0 VC models (F/L kit only) Note ) With back pressure check valve D DIN rail mounting D0 With DIN rail bracket (Without DIN rail) D Note ) With ejector unit K Note ) Special wiring spec. (Except double wiring) N With name plate Note ) External pilot Note ) When two or more symbols are specified, indicate them alphabetically. Example: -N Note ) Models with a suffix - have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet. Note ) Specify the wiring specifications by means of the manifold specification sheet. (Except L kit) Note ) Indicate for the valve with external pilot. Note ) : Station. Example: D08: The number of stations that may be displayed is longer than the manifold number of stations. Simple specials are available with SMC Simple Specials System. efer to the WE catalog for details on applicable models. Kit type/electrical entry/cable length F kit (D-sub connector) Top entry kit (Flat ribbon cable) Top entry J kit (Flat ribbon cable 0) Top entry kit G (Flat ribbon cable with terminal block) The voltage used for the valve is VDC. Note ) Note ) 0 0 Order separately SI unit made by OMON Corp. Connector entry direction Top entry Side entry F kit U0 U U U F kit S0 S S S Side entry. Without cable With cable (. m) With cable ( m) With cable ( m) Note ) to stations Connector entry direction Top entry Side entry kit U0 U U U kit S0 S S S Without cable With cable (. m) With cable ( m) With cable ( m) Side entry Note ) to stations Connector entry direction Top entry Side entry U0 U U U S0 S S S Side entry. 7. Note ) esides the above, F/ kit with different number of pins are available. efer to page for details. Note ) efer to page for details. J kit J kit Without cable With cable (. m) With cable ( m) With cable ( m) Note ) to stations G kit 0 Without cable With cable (. m) With cable ( m) With cable ( m). Note ) to stations

3 How to Order Valve Note) For models, DC-type only. ase Mounted [Option] lug-in Unit -VQ000 How to Order Manifold ssembly 0 0 VQ 0 0 VQ000 Clean series Copper/Fluorine/Silicone free + Low particle generation ctuation type -position single T Metal ubber -position double -position double -position closed center -position exhaust center -position pressure center kit (Terminal block box) Seal 0 Metal seal ubber seal Function Symbol Specifications DC C (0. W) Standard Note ) High-speed (0.9 W) response type High-pressure type K Note ) (0.9 W) (.0 Ma) Negative N Note ) common External Note ) pilot Note ) efer to page for power consumption of C type. Note ) Metal seal only Note ) For external pilot and negative common specifications, refer to Semi-standard on pages to. Note ) When two or more symbols are specified, indicate them alphabetically. Combination of [] and [K] is not possible.. 9 T kit 0 Terminal block box to stations Note ) L L kit kit (Lead wire) 0 Q Note) For models, DC-type only. Manual override : Non-locking : Locking push type type (Tool required) (Tool required) C: Locking type (Manual) Light/surge voltage suppressor Yes E Note) Note) Not applicable to the S kit. D: Slide locking type (Manual) Coil voltage Note) Note) 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC (0/0 Hz) 0 VC (0/0 Hz) VDC VDC Note) 00 and 0 VC: F/L kit only With cable (0. m) With cable (. m) With cable ( m) Example Single solenoid ( VDC) VQ00- ( sets) m D side U side D-sub connector cable assembly XT00-DS-00 VQ00- VQ00- VQ00- F kit (D-sub connector) VVQ-09CFU VQ00- VQ00- VVQ000- VQ00- VQ00- VQ00- VQ00- VQ00- VQ00- Double solenoid ( VDC) VQ00- ( sets) lanking plate VVQ000- ( set) VQ00- VQ00- VQ00- VQ00- VVQ000- VQ00- VQ00- VQ00- VVQ000- Cylinder port fitting size C: With ø One-touch fitting Manifold base (9 stations) VVQ-09CFU set (F kit 9-station manifold base part no.) sets (Single solenoid part no.) sets (Double solenoid part no.) set (lanking plate part no.) The asterisk denotes the symbol for assembly. refix it to the part no. of the solenoid valve, etc. Specify the part numbers for valves and options together beneath the manifold base part number. esides, when the arrangement will be complicated, specify them by means of the manifold specification sheet. Caution Use the standard (DC) specification when continuously energizing for long periods of time.. to 8 stations kit S (Serial transmission) S kit 0 H Q V Z ZN The valve is equipped with an indicator light and surge voltage suppressor, and the voltage is VDC. The dust proof SI unit is also available. efer to page for details. Note) efer to SI Unit art No. on page when ordering the CE-compliant SI unit. Without SI unit NKE Corp.: Fieldbus H System DeviceNet OMON Corp.: Compous/S ( outputs) OMON Corp.: Compous/S (8 outputs) CC-Link CompoNet (ositive common) CompoNet (Negative common). Note ) Max. stations Max. stations Max. 8 stations Max. stations Directional Control Valves Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control Flow Control ressure Switches/ ressure Sensors

4 kit (Circularconnector) - VQ000 ase Mounted lug-in Unit Note) For models, DC-type only. [Option] 0 station Note ) VVQ VQ000 Side entry Manifold lug-in unit Note ) Top entry Connector entry direction Top entry Side entry 08 C F U Cylinder port Kit type Symbol ort size Symbol ort size C C C8 CM L L Note ) Top entry Connector entry direction. Top entry Side entry U0 S0 Without cable Note ) F U F S With cable (. m) to kit U kit S With cable ( m) stations U S With cable ( m) With ø One-touch fitting With ø One-touch fitting With ø8 One-touch fitting Mixed sizes and with port plug Top ported elbow with ø One-touch fitting Top ported elbow with ø One-touch fitting Kit type/electrical entry/cable length F T 0 0 Clean series Copper/Fluorine/ Silicone free + Low particle generation The maximum and minimum number of stations are varied depending on kit. (efer to the below table.) Simple specials are available with SMC Simple Specials System. efer to the WE catalog for details on applicable models. kit (D-sub connector) kit (Terminal block box) kit U0 U U U L S0 S S S kit (Lead wire) L8 8 LM Note ) MM Note ) kit (Flat ribbon cable) kit How to Order Manifold Without cable With cable (. m) With cable ( m) With cable ( m) Top ported elbow with ø8 One-touch fitting ottom ported elbow with ø One-touch fitting ottom ported elbow with ø One-touch fitting ottom ported elbow with ø8 One-touch fitting Elbow port, mixed sizes Mixed size for different types of piping, option installed Side entry Side entry 0 Top entry. 7 Connector entry direction Top entry Side entry. Note ) to stations J kit S J U0 U U U Q Note) For models, DC-type only. Note ) Indicate Mixed size and with port plug by means of the manifold specification sheet. Note ) When selecting the mixed size for different types of piping, dual flow fitting assembly, or double check block (direct mounting), enter MM and give instructions on the manifold specification sheet. Note ) Inch-size One-touch fittings are also available. efer to page for details. kit (Flat ribbon cable 0) J kit S0 S S S Without cable With cable (. m) With cable ( m) With cable ( m) kit (Serial transmission) Option Symbol Option 00/0 VC models (F/L kit only) Note ) With back pressure check valve D DIN rail mounting D0 With DIN rail bracket (Without DIN rail) D Note ) DIN rail length specified K Note ) Special wiring spec. (Except double wiring) N With name plate Note ) External pilot Note ) When two or more symbols are specified, indicate them alphabetically. Example: -DN Note ) Models with a suffix - have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet. Note ) Specify the wiring specifications by means of the manifold specification sheet. (Except L kit) Note ) Indicate for the valve with external pilot. Note ) : Station. Example: D08: The number of stations that may be displayed is longer than the manifold number of stations. Note ) to stations kit G (Flat ribbon cable with terminal block) U0 G U kit U U Note ) The valve is equipped with an indicator light and surge voltage suppressor, and the voltage is VDC. The dusttight SI unit is available. efer to page for details. Dust-tight, Water-jet-proof (I) is available. Note ) M Without cable With cable (. m) With cable ( m) With cable ( m) The voltage used for the valve is VDC.. Note ) to stations C Dust-tight/Water-jet-proof (I) compatible Note ) T kit. 9 0 Terminal block box to 0 stations Note ) Dust-tight/Water-jet-proof (I) compatible Note ) L kit 0. With cable (0. m) With cable (. m) With cable ( m) Note ) esides the above, F/ kit with different number of pins are available. efer to page for details. Note ) efer to page for details. 7 to 8 stations. Note) efer to SI Unit art No. on page when ordering the CE-compliant SI unit. 0 Without SI unit H NKE Corp.: Fieldbus H System S Q DeviceNet Max. kit OMON Corp.: Compous/S ( outputs) stations OMON Corp.: Compous/S (8 outputs) Max. 8 stations V CC-Link Max. stations Dust-tight/Water-jet-proof Note ) Max. (I) compatible Note ) stations M kit 0. 7 Without cable Note ) With cable (. m) to With cable ( m) stations With cable ( m) Note ) efer to the pages on respective kits for I type. (T/L/S/M kit) Note ) Serial transmission system with I enclosure applicable to input/output is also available. efer to page for details.

5 ase Mounted lug-in Unit -VQ000 How to Order Valve Note) For models, DC-type only. [Option] How to Order Manifold ssembly 0 0 VQ 0 0 VQ000 ctuation type -position single Clean series Copper/Fluorine/Silicone free + Low particle generation Metal ubber -position double -position double -position closed center -position exhaust center -position pressure center Note) For sub-plate single unit type, refer to page 0. Symbol K N Note ) Note ) Note ) Specifications Standard High-speed response type Negative common External pilot 0 High-pressure type (.0 Ma) Seal Metal seal ubber seal Function DC C (0. W) Note ) (0.9 W) (0.9 W) Note ) For power consumption of C type, refer to page. Note ) Metal seal only Note ) For external pilot and negative common specifications, refer to Semi-standard on pages to. Note ) When two or more symbols are specified, indicate them alphabetically. Combination of [] and [K] is not possible. Light/surge voltage suppressor E Note) Yes Note) Not applicable to the S kit. Caution Use the standard (DC) specification when continuously energizing for long periods of time. Q Note) For models, DC-type only. Enclosure Dust-tight/water-jetproof type (I) W Note) Note) T, L, S and M kits only Coil voltage Note) Note) 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC (0/0 Hz) 0 VC (0/0 Hz) VDC VDC Note) 00 and 0 VC: F/L kit only Manual override : Non-locking push type (Tool required) : ush-locking slotted type (Tool required) C: Locking type (Manual) D: Slide locking type (Manual) Example Single solenoid ( VDC) VQ00- ( sets) m D-sub connector cable assembly XT00-DS-00 F kit (D-sub connector) VVQ-08C8FU VQ00- VQ00- VVQ000- Double solenoid ( VDC) VQ00- ( sets) VQ00- VQ00- VQ00- VQ00- VQ00- VQ00- VQ00- D side U side lanking plate VVQ000- ( set) VVQ000- Cylinder port fitting size C8: With ø8 One-touch fitting Manifold base (8 stations) VVQ-08C8FU set (F kit 8-station manifold base part no.) sets (Single solenoid part no.) sets (Double solenoid part no.) set (lanking plate part no.) The asterisk denotes the symbol for assembly. refix it to the part no. of the solenoid valve, etc. Specify the part numbers for valves and options together beneath the manifold base part number. esides, when the arrangement will be complicated, specify them by means of the manifold specification sheet. Directional Control Valves Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control Flow Control 8 ressure Switches/ ressure Sensors

6 7 8 -VQ000/000 -VQ000: Manifold Options. 7 to 7 lanking plate assembly VVQ000- Individual SU spacer VVQ C N7 Individual EXH spacer VVQ C N7 SU block plate VVQ000- EXH block base assembly F C, C C, M VVQ N, N L N7 C (SU port) ø One-touch fitting C (EXH port) ø One-touch fitting ack pressure check valve assembly [-] VVQ000-8 One set includes pcs. Name plate [-N] VVQ000- N NC-Station ( to Max. stations) 9 lanking plug KQ- DIN rail mounting bracket [-D/-D0/-D ] VVQ VQ000: Manifold Options. 7 to 7 lanking plate assembly VVQ000- Individual SU spacer VVQ C8 N9 C8 (SU port) ø8 One-touch fitting Individual EXH spacer VVQ C8 N9 C8 (EXH port) ø8 One-touch fitting SU block plate VVQ000- EXH block plate VVQ000-9 One set includes pcs. ack pressure check valve assembly [-] VVQ000-8 One set includes pcs. Name plate [-N] VVQ000-N-Station ( to Max. stations) lanking plug KQ- DIN rail mounting bracket [-D/-D0/-D ] VVQ

7 Flow Control ressure Control ir reparation Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders Directional Control Valves 0 ressure Switches/ ressure Sensors

8 VQ000/000 - ase Mounted lug-in Unit Model VQ000 VQ000 -position -position -position -position ctuation type Single Double Closed center Exhaust center ressure center Single Double Closed center Exhaust center ressure center Model Metal seal -VQ00 ubber seal -VQ0 Metal seal -VQ00 ubber seal -VQ0 Metal seal -VQ00 ubber seal -VQ0 Metal seal -VQ00 ubber seal -VQ0 Metal seal -VQ00 ubber seal -VQ0 Metal seal -VQ00 ubber seal -VQ0 Metal seal -VQ00 ubber seal -VQ0 Metal seal -VQ00 ubber seal -VQ0 Metal seal -VQ00 ubber seal -VQ0 Metal seal -VQ00 ubber seal -VQ0 Flow rate characteristics Note ) / ( /) / / (/ /) C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv Note ) The values are given for port size C: (VQ000), C8: (VQ000) without back pressure check valve. Note ) s per JIS (Supply pressure 0. Ma; with indicator light/surge voltage suppressor; clean air The response time is subject to the pressure and quality of the air.) The values at the time of ON are given for double types. esponse time (ms) Note ) Standard: 0. W or less 0 or less or less 0 or less or less or less or less or less or less or less 9 or less or less 0 or less or less 8 or less or less 8 or less or less 8 or less or less High-speed response: 0.9 W or less or less 0 or less or less 0 or less or less 0 or less or less 0 or less or less or less or less or less 0 or less 9 or less or less 9 or less or less 9 or less or less C 9 or less or less or less 0 or less 0 or less 7 or less 0 or less 7 or less 0 or less 7 or less 9 or less or less 0 or less or less 8 or less or less 8 or less or less 8 or less or less Weight (g)

9 ase Mounted lug-in Unit Symbol -position single Metal ubber -position double -position double -position closed center -position exhaust center -position pressure center Manifold Specifications ase model Standard Specifications Connection type -VQ000/000 F kit D-sub connector kit Flat ribbon cable J kit Flat ribbon cable (0) G kit Flat ribbon cable with terminal - VQ000 VVQ- block T kit Terminal block box L kit Lead wire S kit Serial transmission F kit D-sub connector kit Flat ribbon cable J kit Flat ribbon cable (0) G kit Flat ribbon cable with terminal - VQ000 VVQ- block T kit Terminal block box L kit Lead wire S kit Serial transmission M kit Circular connector Note ) Inch-size One-touch fittings are also available. efer to page for details. Note ) efer to page for details. Valve specifications Electrical specifications Valve type Fluid Maximum operating pressure Single Minimum Double operating pressure -position -position mbient and fluid temperature Lubrication Manual override Impact/Vibration resistance Note ) Enclosure Coil rated voltage llowable voltage fluctuation Coil insulation type VDC VDC ower consumption 00 VC (Current) 0 VC 00 VC 0 VC iping direction Side Side iping specifications ort size Note ) (), () (), () C8 (ø8) Option: Direct EXH outlet with built-in silencer C0 (ø0) Option: Direct EXH outlet with built-in silencer Metal seal ubber seal ir, Inert gas ir, Inert gas 0.7 Ma (High-pressure type:.0 Ma) 0.7 Ma 0. Ma 0. Ma 0. Ma 0. Ma 0. Ma 0. Ma 0. Ma 0 to 0 C Note ) Not required ush type, Locking type (Tool required, Manual) semi-standard 0/0 m/s Dust-protected; Dust-tight, Water-jet-proof (I) Note ), VDC, 00, 0, 00, 0 VC (0/0 Hz) ±0% of rated voltage Equivalent to Class 0. W DC (7 m), 0.9 W DC (0 m) Note ) 0. W DC ( m), 0.9 W DC (80 m) Note ) Inrush 0.9 V (0 m), Holding 0.9 V (0 m) Inrush.0 V (9 m), Holding.0 V (9 m) Inrush. V ( m), Holding. V ( m) Inrush.8 V ( m), Holding.8 V ( m) Note ) Use dry air to prevent condensation when operating at low temperatures. Note ) Impact resistance No malfunction occurred when it was tested in the axial direction and at right angles to the main valve and armature in both energized and de-energized states once for each condition. (Default settings) Vibration resistance No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed in both energized and de-energized states in the axial direction and at right angles to the main valve and armature. (Default settings) Note ) Value for high-speed response, high-voltage type (0.9 W) Note ) Dust-tight, Water-jet-proof (I) is available on T/L/S/M kit of the VQ000. C (ø.) C(ø) C (ø) M (M thread) C (ø) C (ø) C8 (ø8) Note ) pplicable stations F//T kit to stations J/G/S kit to stations L kit to 8 stations F/ kit to stations J/G/S kit to stations L kit to 8 stations T kit to 0 stations pplicable solenoid valve VQ 00 VQ 0 VQ 00 VQ 0 -station weight (g) (Single) 7 (Double, -position) 07 (Single) 9 (Double, -position) Directional Control Valves Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control port port Flow Control Type of connection -VVQ - VVQ, port port Type of connection, port port ressure Switches/ ressure Sensors

10 -VQ000/000 F Kit (D-sub connector) - VVQ - VVQ D-sub connector reduces installation labor for electrical connections. Using the D-sub connector (), ( as semi-standard) conforming to MIL standard permits the use of commercial connectors and gives a wide interchangeability. Top or side receptacle position can be selected in accordance with the available mounting space. Maximum stations are. D-sub Connector ( ins) Manifold Specifications - VQ000 - VQ000 iping specifications iping ort size direction Side Side (), () C8 C0 (), () C, C, C, M C, C, C8 pplicable stations Max. stations Max. stations XT00-DS The D-sub connector cable assembly can be ordered individually or included in a specific manifold model no. efer to How to Order Manifold. L Multi-core vinyl cable 0. mm x cores ø0 x M. x 0. Socket side Terminal no. D-sub connector cable assembly Cable ssembly part no. Note length (L). m m m XT00-DS-0 XT00-DS-00 XT00-DS-00 Note ) Types with pins are also available. efer to page for details. Note ) Lengths other than the above are also available. lease contact SMC for details. Cable cores x WG For other commercial connectors, use a pins type with female connector conforming to MIL-C-08. Cannot be used for transfer wiring. Example of connector manufacturers Fujitsu Limited Japan viation Electronics Industry, Limited J.S.T. Mfg. Co., Ltd. HIOSE ELECTIC CO., LTD. Electrical characteristics Item roperty Conductor resistance or less Ω/km, 0 C Voltage limit 000 V, minute, C Insulation resistance or more MΩ/km, 0 C Note) The minimum bending radius of the D-sub connector cable is 0 mm. Wire color by terminal no. of D-sub connector cable assembly Terminal no. Lead wire color Dot marking Cable ssembly lack rown ed Orange Yellow ink lue urple Gray White White Yellow Orange Yellow ink lue urple Gray Orange ed rown ink Gray lack White White lack lack ed ed ed lack lack White lack White White ed ed White How to Order Manifold 0 0 VVQ 08 C F U Clean series Copper/Fluorine/Silicone free + Low particle generation VQ000 VQ000 0 stations Manifold lug-in unit stations Note) efer to page for details. Connector entry U S direction Top entry Side entry Q Note) For models, DC-type only. Cable (Length) 0 Without cable With cable (. m) With cable ( m) With cable ( m) Cylinder port Symbol ort size VQ000 VQ000 C Note ) C Note ) C Note ) C8 Note ) M With ø. One-touch fitting With ø One-touch fitting With ø One-touch fitting With ø8 One-touch fitting M thread CM Note ) Note ) Mixed sizes and with port plug MM Note ) Mixed size for different types of piping, option installed Note ) Insert L (Top ported) or (ottom ported) for elbow type. Example) (ottom ported elbow with ø One-touch fitting) Note ) Indicate LM for models with elbow fittings and mixed cylinder port sizes. Note ) Indicate Mixed sizes and with port plug by means of the manifold specification sheet. Note ) When selecting the mixed size for different types of piping, dual flow fitting assembly, or double check block (direct mounting), enter MM and give instructions on the manifold specification sheet. Note ) Inch-size One-touch fittings are available. efer to Semi-standard on page for details. Note) For models, DC-type only. Option Symbol D D0 D Note ) Note ) K Note ) N Note ) [Option] Option 00/0 VC models (F/L kit only) With back pressure check valve DIN rail mounting With DIN rail bracket (Without DIN rail) DIN rail length specified ( : 0 to ) Special wiring specifications (Except double wiring) With name plate External pilot Note ) When two or more symbols are specified, indicate them alphabetically. Example) -N Note ) Models with a suffix - have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet. Note ) The number of stations that may be displayed is longer than the manifold number of stations. Note ) Specify the wiring specifications by means of the manifold specification sheet. Note ) Indicate for the valve with external pilot.

11 ase Mounted lug-in Unit -VQ000/000 Directional Control Valves D side U side D side U side VQ000 VQ000 ctuation type -position single -position double -position closed center -position exhaust center -position pressure center 0 Seal Metal seal ubber seal The total number of stations is tabulated starting from station one on the D-side. How to Order Valve 0 0 -VVQ -VVQ VQ 0 0 Clean series Copper/Fluorine/Silicone free + Low particle generation Function Symbol Specifications DC (0. W) Standard C High-speed (0.9 W) response type High-pressure type K Note ) (0.9 W) (.0 Ma) Negative N Note ) common External Note ) pilot Note ) efer to page for power consumption of C type. Note ) Metal seal only Note ) For external pilot and negative common specifications, refer to Semi-standard on pages to. Note ) When two or more symbols are specified, indicate them alphabetically. Combination of [] and [K] is not possible. Electrical Wiring Specifications Station Station Station Station Station Station Station 7 Connector Station 8 terminal no. s the standard electrical wiring Station 9 specifications, double wiring (connected Station 0 to SOL. and SOL.) is adopted for the internal wiring of each station for Station stations or less, regardless of valve and option types. Station Mixed single and double wiring is available as semi-standard. efer to page for details. Note) When using the negative common specifications, use valves for negative common. (efer to page.) efer to Semi-standard on page for details. Note) For models, DC-type only. Note ) Q Note) For models, DC-type only. Manual override C D Non-locking push type (Tool required) Locking type (Tool required) Locking type (Manual) Slide locking type (Manual) Light/surge voltage suppressor E D-sub connector Yes [Option] D-sub connector assembly 0 XT00-DS- 00 Wire color 00 Terminal no. olarity Lead wire color Dot marking SOL. (+) lack SOL. (+) Yellow lack SOL. (+) rown SOL. (+) ink lack SOL. (+) ed SOL. (+) lue White SOL. (+) Orange SOL. 7 (+) urple SOL. (+) Yellow SOL. 8 (+) Gray SOL. (+) ink SOL. 9 (+) Orange lack SOL. 7 (+) lue SOL. 0 (+) ed White SOL. 8 (+) urple White SOL. (+) rown White SOL. 9 (+) Gray lack SOL. (+) ink ed SOL. 0 (+) White lack SOL. (+) Gray ed SOL. (+) White ed SOL. (+) lack White SOL. (+) Yellow ed SOL. (+) White Note) COM. (+) Orange ed m ositive COM spec. Negative COM spec. How to Order Manifold ssembly Specify the part numbers for valves and options together beneath the manifold base part number. <Example> D-sub connector kit with cable ( m) VVQ-09CFU VQ00- VQ00- VQ00- VVQ000- refix the asterisk to the part no. of the solenoid valve, etc. set Manifold base part no. sets Valve part no. ( to ) sets Valve part no. ( to ) sets Valve part no. ( 7 to 8) set lanking plate part no. (Station 9) Write sequentially from the st station on the D-side. When part no. written collectively are complicated, specify them by means of the manifold specification sheet. D side U side Coil voltage 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC (0/0 Hz) 0 VC (0/0 Hz) VDC VDC Caution Use the standard (DC) specification when continuously energizing for long periods of time. VQ00- VQ00- VQ00- VQ00- VQ00- VQ00- VQ00- VQ00- VVQ000- Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control Flow Control ressure Switches/ ressure Sensors

12 X -VQ000/000 F kit (D-sub connector) -VVQ < >: C The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-FS]. () pplicable connector: D-sub connector () (Complies with MIL-C-08). <7.>. 8. (L) (L) L L Indicator light = 0. 7 Manual override (.) 9. <00.> 0. X ().8 [] [ ]: pins (top entry) D side 7 8 n C8 [() EXH port] C8: ø8 One-touch fitting 9. (.) () M mounting hole U side DIN rail clamp screw 0.7 (7.) C, C, C, M [(), () port] C: ø. One-touch fitting C: ø One-touch fitting C: ø One-touch fitting M: M thread 8. = 0.. C8 [() SU port] C8: ø8 One-touch fitting Dimensions L n L L (L) (L) With ejector unit: Formula L = 0.n (Number of ejector units x.7) L = 0.n +. + (Number of ejector units x.7) L is L plus about 0. Formula L = 0.n +., L = 0.n n: Station (Maximum stations)

13 ase Mounted lug-in Unit -VQ000/000 -VVQ < >: C The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-FS]. Directional Control Valves pplicable connector: D-sub connector () (Complies with MIL-C-08) () <77.> 0 <.9> D side. EXH X (L) (L) (.) L L =.. Indicator light 0.9 Manual override 7 8 C, C, C8 [(), () port] C: ø One-touch fitting C: ø One-touch fitting C8: ø8 One-touch fitting C0 [() EXH port] C0: ø0 One-touch fitting X EXH = n (.) (). C0 [() SU port] C0: ø0 One-touch fitting x M mounting hole U side DIN rail clamp screw 9 (7.) () Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control Dimensions L n L L (L) (L) Formula L = n +, L = n n: Station (Maximum stations) Flow Control ressure Switches/ ressure Sensors

14 -VQ000/000 kit (Flat ribbon cable) - VVQ - VVQ MIL flat ribbon cable connector reduces installation labor for electrical connection. Using the connector for flat ribbon cable () conforming to MIL standard permits the use of commercial connectors and gives a wide interchangeability. Top or side receptacle position can be selected in accordance with the available mounting space. Maximum stations are. Flat ibbon Cable ( ins) Cable ssembly Manifold Specifications -VQ000 -VQ000 iping direction Side Side iping specifications ort size (), () (), () C8 C, C, C, M C0 C, C, C8 D side U side pplicable stations Max. stations Max. stations XT00-FC- to Flat ribbon cable connector assembly can be ordered individually or included in a specific manifold model no. efer to How to Order Manifold. ed - VVQ Terminal no. Flat ibbon Cable Connector ssembly Cable length (L) ssembly part no.. m XT00-FC- m XT00-FC- m XT00-FC- Note Cable cores x 8WG For other commercial connectors, use a pins type with strain relief conforming to MIL-C-80. Cannot be used for transfer wiring. Connector manufacturers example HIOSE ELECTIC CO., LTD. M Japan Limited Fujitsu Limited Japan viation Electronics Industry, Limited J.S.T. Mfg. Co., Ltd. Oki Electric Cable Co., Ltd. Note ) Other than the above model, 0,, 0 are also available. efer to page for details. Note ) Lengths other than the above are also available. lease contact SMC for details. D side U side - VVQ The total number of stations is tabulated starting from one on the D-side. How to Order Manifold VVQ 08 C U Clean series Copper/Fluorine/Silicone free + Low particle generation VQ000 VQ000 Manifold lug-in unit 0 stations stations Note) efer to page for details. Connector entry direction U S Cylinder port Symbol C Note ) C Note ) C Note ) C8 Note ) M CM Note ) Note ) MM Note ) Top entry Side entry ort size With ø. One-touch fitting With ø One-touch fitting With ø One-touch fitting With ø8 One-touch fitting M thread Mixed sizes and with port plug Mixed size for different types of piping, option installed VQ000 VQ000 Cable (Length) 0 Without cable With cable (. m) With cable ( m) With cable ( m) Note ) Insert L (Top ported) or (ottom ported) for elbow type. Example) (ottom ported elbow with ø One-touch fitting) Note ) Indicate LM for models with elbow fittings and mixed cylinder port sizes. Note ) Indicate Mixed sizes and with port plug by means of the manifold specification sheet. Note ) When selecting the mixed size for different types of piping, dual flow fitting assembly, or double check block (direct mounting), enter MM and give instructions on the manifold specification sheet. Note ) Inch-size One-touch fittings are available. efer to Semi-standard on page for details. Q Note) For models, DC-type only. Note) For models, DC-type only. Option Symbol Note ) D D0 D K Note ) Note ) N Note ) Option [Option] With back pressure check valve DIN rail mounting With DIN rail bracket (Without DIN rail) DIN rail length specified ( : 0 to ) Special wiring specifications (Except double wiring) With name plate External pilot Note ) When two or more symbols are specified, indicate them alphabetically. Example) -N Note ) Models with a suffix - have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet. Note ) The number of stations that may be displayed is longer than the manifold number of stations. Note ) Specify the wiring specifications by means of the manifold specification sheet. Note ) Indicate for the valve with external pilot.

15 ase Mounted lug-in Unit -VQ000/000 Directional Control Valves Electrical Wiring Specifications Flat ribbon cable connector Terminal no. olarity SOL. (+) Station SOL. (+) SOL. (+) Station SOL. (+) SOL. (+) Station SOL. (+) SOL. 7 (+) Station SOL. 8 (+) SOL. 9 (+) Station SOL. 0 (+) SOL. (+) Station SOL. (+) SOL. (+) Station 7 SOL. (+) SOL. (+) Station 8 SOL. (+) SOL. 7 (+) Station 9 SOL. 8 (+) Connector SOL. 9 (+) terminal no. Station 0 SOL. 0 (+) SOL. (+) Station SOL. (+) SOL. Station (+) SOL. (+) Triangle mark COM. (+) indicator position COM. (+) Note) ositive Negative Electrical wiring COM spec. COM spec. specifications How to Order Valve 0 VQ 0 0 VQ000 VQ000 0 Clean series Copper/Fluorine/Silicone free + Low particle generation ctuation type -position single -position double -position closed center -position exhaust center -position pressure center 0 Seal Metal seal ubber seal Caution Use the standard (DC) specification when continuously energizing for long periods of time. Function Symbol Specifications DC (0. W) Standard N High-speed (0.9 W) response type High-pressure type K Note ) (0.9 W) (.0 Ma) Note ) Negative common Note ) External pilot Note) For models, DC-type only. Q Note) For models, DC-type only. Manual override C D Non-locking push type (Tool required) Locking type (Tool required) Locking type (Manual) Slide locking type (Manual) Light/surge voltage suppressor E C Note ) s the standard electrical wiring specifications, double wiring (connected to SOL. and SOL.) is adopted for the internal wiring of each station for stations or less, regardless of valve and option types. Mixed single and double wiring is available as semi-standard. efer to page for details. Note) When using the negative common specifications, use valves for negative common. (efer to page.) efer to Semi-standard on page for details. [Option] Yes Coil voltage 00 VC (0/0 Hz) 0 VC (0/0 Hz) VDC VDC Note ) efer to page for power consumption of C type. Note ) Metal seal only Note ) efer to Semi-standard on pages to for external pilot and negative common specifications. Note ) When two or more symbols are specified, indicate them alphabetically. Combination of [] and [K] is not possible. How to Order Manifold ssembly Specify the part numbers for valves and options together beneath the manifold base part number. <Example> Flat ribbon cable kit with cable ( m) VVQ-09CU VQ00- VQ00- VQ00- VVQ000- refix the asterisk to the part no. of the solenoid valve, etc. m set Manifold base part no. sets Valve part no. ( to ) sets Valve part no. ( to ) sets Valve part no. ( 7 to 8) set lanking plate part no. (Station 9) Write sequentially from the st station on the D-side. When part no. written collectively are complicated, specify them by means of the manifold specification sheet. D side U side VQ00- VQ00- VQ00- VQ00- VQ00- VQ00- VQ00- VQ00- VVQ000-8 Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control Flow Control ressure Switches/ ressure Sensors

16 -VQ000/000 kit (Flat ribbon cable) -VVQ < >: C The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-S]. pplicable connector: Flat ribbon cable connector () (Complies with MIL-C-80). <7.> () (L) (L) L L Indicator light = 0. 7 Manual override (.) <00.> () (.). X X ().8 M mounting hole D side 7 8 n U side C8 [() EXH port] C8: ø8 One-touch fitting DIN rail clamp screw (7.) C, C, C, M [(), () port] C: ø. One-touch fitting C: ø One-touch fitting C: ø One-touch fitting M: M thread 8. = 0.. C8 [() SU port] C8: ø8 One-touch fitting Dimensions L n L L (L) (L) With ejector unit: Formula L = 0.n (Number of ejector units x.7) L = 0.n +. + (Number of ejector units x.7) L is L plus about 0. Formula L = 0.n +., L = 0.n n: Station (Maximum stations)

17 ase Mounted lug-in Unit -VQ000/000 -VVQ < >: C The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-S]. Directional Control Valves pplicable connector: Flat ribbon cable connector () (Complies with MIL-C-80) () 7. <77.> 7. 0 <.9> Flat ribbon cable connector assembly () XT00-FC-:. m XT00-FC-: m XT00-FC-: m EXH X L L. =. Indicator light 0.9 Manual override (L) (L) D side 7 8 n U side C, C, C8 [(), () port] C: ø One-touch fitting C: ø One-touch fitting C8: ø8 One-touch fitting C0 [() EXH port] C0: ø0 One-touch fitting X = EXH (.) () (.) DIN rail clamp screw. C0 [() SU port] C0: ø0 One-touch fitting x M mounting hole 9 (7.) () Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control Dimensions L n L L (L) (L) Formula L = n +, L = n n: Station (Maximum stations) Flow Control ressure Switches/ ressure Sensors 0

18 J -VQ000/000 kit (Flat ribbon cable) XT00-FC0- to Flat ribbon cable connector assembly can be ordered individually or included in a specific manifold model no. efer to How to Order Manifold. -VVQ -VVQ MIL flat ribbon cable connector reduces installation labor for electrical connection. Using the connector for flat ribbon cable connectors (0) conforming to MIL standard permits the use of connector put on the market and gives a wide interchangeability. Top or side receptacle position can be selected in accordance with the available mounting space. Maximum stations are. Flat ibbon Cable (0 ins) Manifold Specifications -VQ000 -VQ000 Cable ssembly iping specifications iping ort size direction Side Side (), () C8 C0 (), () C, C, C, M C, C, C8 D side U side pplicable stations Max. stations Max. stations ed -VVQ Terminal no. Flat ibbon Cable Connector ssembly Cable length (L). m m m ssembly part no. XT00-FC0- XT00-FC0- XT00-FC0- Note Cable 0 cores x 8WG For other commercial connectors, use a 0 pins with strain relief conforming to MIL-C-80. Cannot be used for transfer wiring. Example of connector manufacturers HIOSE ELECTIC CO., LTD. M Japan Limited Fujitsu Limited 0 stations VQ000 VQ000 Manifold lug-in unit stations Japan viation Electronics Industry, Limited J.S.T. Mfg. Co., Ltd. Oki Electric Cable Co., Ltd. Note) Lengths other than the above are also available. lease contact SMC for details. How to Order Manifold 0 VVQ 08 C J U 0 Clean series Copper/Fluorine/Silicone free + Low particle generation Note) efer to page for details. Connector entry U S direction Top entry Side entry Cable (Length) 0 Without cable With cable (. m) With cable ( m) With cable ( m) Cylinder port Symbol ort size VQ000 VQ000 C Note ) C Note ) C Note ) C8 Note ) M With ø. One-touch fitting With ø One-touch fitting With ø One-touch fitting With ø8 One-touch fitting M thread CM Note ) Note ) Mixed sizes and with port plug MM Note ) Mixed size for different types of piping, option installed Note ) Insert L (Top ported) or (ottom ported) for elbow type. Example) (ottom ported elbow with ø One-touch fitting) Note ) Indicate LM for models with elbow fittings and mixed cylinder port sizes. Note ) Indicate Mixed sizes and with port plug by means of the manifold specification sheet. Note ) When selecting the mixed size for different types of piping, dual flow fitting assembly, or double check block (direct mounting), enter MM and give instructions on the manifold specification sheet. Note ) Inch-size One-touch fittings are available. efer to Semi-standard on page for details. The total number of stations is tabulated starting from one on the D-side. Q D side U side -VVQ [Option] Option Symbol Option Note ) With back pressure check valve D DIN rail mounting D0 With DIN rail bracket (Without DIN rail) DIN rail length specified D Note ) ( : 0 to ) Special wiring specifications K Note ) (Except double wiring) N Note ) With name plate External pilot Note ) When two or more symbols are specified, indicate them alphabetically. Example) -N Note ) Models with a suffix - have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet. Note ) The number of stations that may be displayed is longer than the manifold number of stations. Note ) Specify the wiring specifications by means of the manifold specification sheet. Note ) Indicate for the valve with external pilot.

19 ase Mounted lug-in Unit -VQ000/000 Directional Control Valves Electrical Wiring Specifications Flat ribbon cable connector Station Connector terminal no VQ 0 0 VQ000 VQ000 ctuation type Triangle mark indicator position How to Order Valve 0 0 Clean series Copper/Fluorine/Silicone free + Low particle generation -position single -position double -position closed center -position exhaust center -position pressure center 0 Station Station Station Station Station Station 7 Station 8 Seal Metal seal ubber seal Terminal no. olarity SOL. 0 (+) SOL. 8 (+) SOL. (+) SOL. (+) SOL. (+) SOL. 0 (+) SOL. 8 (+) SOL. (+) SOL. 9 (+) SOL. 7 (+) SOL. (+) SOL. (+) SOL. (+) SOL. 9 (+) SOL. 7 (+) SOL. (+) COM. (+) COM. (+) Note) ositive ositive COM spec. COM spec. [Option] Q Manual override C D Non-locking push type (Tool required) Locking type (Tool required) Locking type (Manual) Slide locking type (Manual) Light/surge voltage suppressor E Function Symbol Specifications DC (0. W) Standard K N Note ) Note ) High-speed (0.9 W) response type High-pressure type (.0 Ma) Negative common Note ) External pilot Yes s the standard electrical wiring specifications, double wiring (connected to SOL. and SOL.) is adopted for the internal wiring of each station for 8 stations or less, regardless of valve and option types. Mixed single and double wiring is available as semi-standard. efer to Semi-standard on page for details. Note) When using the negative common specifications, use valves for negative common. (efer to page,) efer to Semi-standard on page for details. Coil voltage VDC (0.9 W) Note ) Metal seal only Note ) efer to Semi-standard on pages to for external pilot and negative common specifications. Note ) When two or more symbols are specified, indicate them alphabetically. Combination of [] and [K] is not possible. How to Order Manifold ssembly Specify the part numbers for valves and options together beneath the manifold base part number. <Example> Flat ribbon cable kit with cable ( m) VVQ-08CJU VQ00- VQ00- VQ00- VVQ000- refix the asterisk to the part no. of the solenoid valve, etc. m set Manifold base part no. sets Valve part no. ( to ) sets Valve part no. ( to ) set Valve part no. (Station 7) set lanking plate part no. (Station 8) D side U side Write sequentially from the st station on the D-side. When part no. written collectively are complicated, specify them by means of the manifold specification sheet. Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control Flow Control ressure Switches/ ressure Sensors

20 t y p e J -VQ000/000 kit (Flat ribbon cable) -VVQ The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-JS]. pplicable connector: Flat ribbon cable connector (0) (Complies with MIL-C-80) () (L) (L) L L = 0. 7 (.) () (.).8 Indicator light Manual override. D side 7 8 n x M mounting hole U side C8 [() EXH port] C8: ø8 One-touch fitting DIN rail clamp screw X X () (7.) C, C, C, M [(), () port] C: ø. One-touch fitting C: ø One-touch fitting C: ø One-touch fitting M: M thread 8. = 0.. C8 [() SU port] C8: ø8 One-touch fitting Dimensions L n 7 8 L L (L) (L) With ejector unit: Formula L = 0.n (Number of ejector units x.7) L = 0.n +. + (Number of ejector units x.7) L is L plus about 0. Formula L = 0.n +., L = 0.n + 7. n: Station (Maximum stations)

21 ase Mounted lug-in Unit -VQ000/000 -VVQ The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-JS]. Directional Control Valves pplicable connector: Flat ribbon cable connector (0) (Complies with MIL-C-80) () CW type L L.. Indicator light (L) (.) (L) = 0.9 X. D side 7 8 EXH X C, C, C8 [(), () port] C: ø One-touch fitting C: ø One-touch fitting C8: ø8 One-touch fitting Manual override C0 [() EXH port] C0: ø0 One-touch fitting EXH = n U side (.) () DIN rail clamp screw. C0 [() SU port] C0: ø0 One-touch fitting x M mounting hole 9 (7.) () Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control Dimensions L n L L (L) (L) Formula L = n +, L = n + 8 n: Station (Maximum stations) Flow Control ressure Switches/ ressure Sensors

22 -VQ000/000 G kit (Flat ribbon cable with terminal block) - VVQ - VVQ Terminal block for power supply equipped with a 0 pins flat ribbon cable connection for rationalized connection of valves. Solenoid valves and power supply can be connected by the same cable to a specific output unit that requires power supply from the output section to the internal circuit. Maximum stations are. Manifold Specifications - VQ000 - VQ000 iping specifications iping ort size direction Side Side (), () C8 C0 (), () C, C, C, M C, C, C8 pplicable stations Max. stations Max. stations Flat ibbon Cable (0 ins) Cable ssembly XT00-FC0- to Flat ribbon cable connector assembly can be ordered individually or included in a specific manifold model no. efer to How to Order Manifold. U side D side The total number of stations is tabulated starting from station one on the D-side. ed ower supply terminal block (Terminal screw M) Indicator light Terminal no. Flat ibbon Cable Connector ssembly Cable length (L). m m m ssembly part no. XT00-FC0- XT00-FC0- XT00-FC0- Note Cable 0 cores x 8WG For other commercial connectors, use a 0 pins type with strain relief conforming to MIL-C-80. Cannot be used for transfer wiring. Example of connector manufacturers HIOSE ELECTIC CO., LTD. M Japan Limited Japan viation Electronics Industry, Limited J.S.T. Mfg. Co., Ltd. Oki Electric Cable Co., Ltd. Fujitsu Limited Note) Lengths other than the above are also available. lease contact SMC for details. - VVQ D side D side SI unit made by OMON Corp. Mountable for G7-OD (Order separately) - VVQ How to Order Manifold 0 VQ000 VQ000 0 VVQ 08 C G 0 Clean series Copper/Fluorine/Silicone free + Low particle generation stations Note) stations Note) efer to page for details. Manifold lug-in unit Connector entry direction, Top entry U Cylinder port Symbol C Note ) C Note ) C Note ) C8 Note ) M CM Note ) Note ) MM Note ) VQ000 VQ000 ort size With ø. One-touch fitting With ø One-touch fitting With ø One-touch fitting With ø8 One-touch fitting M thread Mixed sizes and with port plug Mixed size for different types of piping, option installed Q Cable (Length) 0 Without cable Cable length. m Cable length m Cable length m VQ000 VQ000 Note ) Insert L (Top ported) or (ottom ported) for elbow type. Example) (ottom ported elbow with ø One-touch fitting) Note ) Indicate LM for models with elbow fittings and mixed cylinder port sizes. Note ) Indicate Mixed sizes and with port plug by means of the manifold specification sheet. Note ) When selecting the mixed size for different types of piping, dual flow fitting assembly, or double check block (direct mounting), enter MM and give instructions on the manifold specification sheet. Note ) Inch-size One-touch fittings are available. efer to Semi-standard on page for details. Option Symbol Option Note ) With back pressure check valve D DIN rail mounting D0 With DIN rail bracket (Without DIN rail) D Note ) DIN rail length specified ( : 0 to ) K Note ) Special wiring specifications (Except double wiring) N Note ) With name plate External pilot [Option] Note ) When two or more symbols are specified, indicate them alphabetically. Example) -N Note ) Models with a suffix - have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet. Note ) The number of stations that may be displayed is longer than the manifold number of stations. Note ) Specify the wiring specifications by means of the manifold specification sheet. Note ) Indicate for the valve with external pilot.

23 ase Mounted lug-in Unit -VQ000/000 Directional Control Valves Connector ssembly Electric circuit diagram (elow wiring is the case of all double solenoid connections.) Flat ribbon cable connector VQ 0 0 VQ000 VQ000 ctuation type Connector terminal no. How to Order Valve 0 0 Clean series Copper/Fluorine/Silicone free + Low particle generation Triangle mark indicator position 0 -position single -position double -position closed center -position exhaust center -position pressure center Seal VDC + Metal seal ubber seal Station Station Station Station Station Station Station 7 Station 8 Coil voltage VDC Function Symbol Specifications DC (0. W) Standard Terminal no. SOL. 0 SOL. 8 SOL. SOL. SOL. SOL. 0 SOL. 8 SOL. SOL. 9 SOL. 7 SOL. SOL. SOL. SOL. 9 SOL. 7 SOL... Manual override C D s the standard electrical wiring specifications, double wiring (connected to SOL. and SOL.) is adopted for the internal wiring of each station for 8 stations or less, regardless of valve and option types. Mixed single and double wiring is available as semi-standard. efer to page for details. [Option] Non-locking push type (Tool required) Locking type (Tool required) Locking type (Manual) Slide locking type (Manual) Light/surge voltage suppressor E Yes Q High-speed (0.9 W) response type Note ) Metal seal only High- pressure type K Note ) (0.9 W) Note ) efer to Semi-standard on page for (.0 Ma) external pilot specifications. Note ) When two or more symbols are specified, External Note ) indicate them alphabetically. Combination pilot of [] and [K] is not possible. How to Order Manifold ssembly Specify the part numbers for valves and options together beneath the manifold base part number. <Example> Flat ribbon cable kit with terminal block with cable ( m) VVQ-08CG VQ00- VQ00- VQ00- refix the asterisk to the part no. of the solenoid valve, etc. set Manifold base part no. sets Valve part no. ( to ) set Valve part no. (Station ) sets Valve part no. ( to 8) VQ00- VQ00- VQ00- VQ00- VQ00- VQ00- VQ00- Write sequentially from the st station on the D-side. When part no. written collectively are complicated, specify them by means of the manifold specification sheet. m U side D side Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control Flow Control ressure Switches/ ressure Sensors

24 -VQ000/000 G kit (Flat ribbon cable with terminal block) -VVQ The dashed lines and dimensions in parentheses indicate DIN rail mounting [-D]. (). Indicator light ower supply terminal block (Terminal screw M) 9 (L) (L) L L = 0. Indicator light 7 (.) Manual override 0 9. () (.).8. (). Triangle mark indicator position x M mounting hole pplicable connector: Flat ribbon cable connector (0) (Complies with MIL-C-80) D side 7 8 n U side C8 [() EXH port] C8: ø8 One-touch fitting DIN rail clamp screw X X (7.) C, C, C, M [(), () port] C: ø. One-touch fitting C: ø One-touch fitting C: ø One-touch fitting M: M thread 8. = 0.. C8 [() SU port] C8: ø8 One-touch fitting Dimensions L n 7 8 L L (L) (L) With ejector unit: Formula L = 0.n (Number of ejector units x.7) L = 0.n (Number of ejector units x.7) L is L plus about 0. Formula L = 0.n +., L = 0.n + n: Station (Maximum stations)

25 + VDC + COM ase Mounted lug-in Unit -VQ000/000 -VVQ The dashed lines indicate DIN rail mounting [-D] (with DIN rail mounting bracket). Directional Control Valves () ower supply terminal block (Terminal screw M) Indicator light Flat ribbon cable connector assembly (0) XT00-FC0-:. m XT00-FC0-: m XT00-FC0-: m. 9. D side. pplicable connector: Flat ribbon cable connector (0) (Complies with MIL-C-80) (L) (L) L Indicator light L. = EXH X C, C, C8 [(), () port] C: ø One-touch fitting C: ø One-touch fitting C8: ø8 One-touch fitting C0 [() EXH port] C0: ø0 One-touch fitting Manual override X EXH = n U side (.) C0 [() SU port] C0: ø0 One-touch fitting () x M mounting hole (.) DIN rail clamp screw. 9 (7.) () Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control Dimensions L n L L (L) (L) Formula L = n +, L = n + 87 n: Station (Maximum stations) Flow Control ressure Switches/ ressure Sensors 8

26 -VQ000/000 T kit (Terminal block box) This kit has a small terminal block inside a junction box. The electrical entry port { - VQ000: G /, - VQ000: G /} permits connection of conduit fittings. Maximum stations: ( - VQ000), 0 ( - VQ000) Enclosure: Dust-tight, Water-jet-proof (I) compatible ( VQ000) Manifold Specifications - - I compliant VQ000 VQ000 Open the terminal block cover to connect the wires to the terminal block. Step. emoving the terminal block cover Loosen the screws on the terminal block cover and open it in the direction shown by the arrow. The cover can then be removed from the terminal block.. iping specifications iping ort size direction Side Side (), () C8 C0 (), () C, C, C, M C, C, C8 VQ000 VQ000 Manifold lug-in unit 0 stations Terminal lock Connection ( -VQ000) M. Step. Mounting the terminal block cover Hook groove (a) on shaft (b) and close the cover. Then tighten the screws. Drip proof plug assembly (for G /): XT00-0 How to Order Manifold VVQ Cover Step. Wiring The diagram on the left shows the terminal block wiring schematic. ll stations are provided with double solenoid wiring. Insert each lead wire into the terminal opening and tighten the screw directly above. How to connect is inserting the lead wire into the terminal window, then tighten the screw on the top. (Tightening torque: 0. to 0. N m) VVQ 08 C T 0 0 Clean series Copper/Fluorine/Silicone free + Low particle generation Note ) stations Note ) VQ000: Max. 0 stations efer to page for details. For negative common specifications of series VQ000, refer to Semi-standard on page. For series VQ000 the standard manifold can be used. (a) (b) Cylinder port Symbol C Note ) C Note ) C Note ) C8 Note ) M CM Note ) Note ) MM Note ) pplicable stations Max. stations Max. 0 stations ort size With ø. One-touch fitting With ø One-touch fitting With ø One-touch fitting With ø8 One-touch fitting M thread Mixed sizes and with port plug Mixed size for different types of piping, option installed VQ000 VQ000 Note ) Insert L (Top ported) or (ottom ported) for elbow type. Example) (ottom ported elbow with ø One-touch fitting) Note ) Indicate LM for models with elbow fittings and mixed cylinder port sizes. Note ) Indicate Mixed sizes and with port plug by means of the manifold specification sheet. Note ) When selecting the mixed size for different types of piping, dual flow fitting assembly, or double check block (direct mounting), enter MM and give instructions on the manifold specification sheet. Note ) Inch-size One-touch fittings are available. efer to Semi-standard on page for details. G / Electrical entry D side D side VQ00- VQ00- - VVQ x G / Electrical entry VQ00- VQ00- VQ00- VQ00- VVQ000- The total number of stations is tabulated starting from station one on the D-side. Electrical Wiring Specifications: -VQ000 Terminal no. olarity COM. COM (+) SOL. (+) Station SOL. (+) SOL. (+) Station SOL. (+) SOL. (+) Station SOL. (+) SOL. (+) Station SOL. (+) SOL. (+) st row --nd row rd row Station SOL. The quantity of terminal blocks used depends (+) SOL. on the number of manifold stations: (+) Station SOL. (+) Manifold Terminal block SOL. 7 (+) to 8 stations rows Station 7 SOL. 7 (+) 9 to stations rows SOL. 8 (+) Station 8 SOL. 8 (+) s the standard electrical wiring SOL. 9 (+) specifications, double wiring Station 9 SOL. 9 (+) (connected to SOL. and SOL. 0 (+) SOL.) is adopted for the Station 0 SOL. 0 (+) internal wiring of each station SOL. (+) for stations or less, regardless Station SOL. (+) of valve and option types. SOL. (+) Mixed single and double wiring Station SOL. (+) is available as semi-standard. COM. COM (+) efer to page for details. ositive Negative Note) When using the negative common specifications, COM spec. COM spec. use valves for negative common. efer to Semi-standard on page for details. Note) For models, DC-type only. Q Note) For models, DC-type only. Option Symbol Option VQ000 VQ000 Note ) D D0 With back pressure check valve DIN rail mounting With DIN rail bracket (Without DIN rail) D Note ) DIN rail length specified ( : 0 to ) K Note ) N Note ) W Special wiring spec. (Except double wiring) With name plate External pilot Enclosure: Dust-tight, Water-jet-proof (I) Note ) When two or more symbols are specified, indicate them alphabetically. Example) -N Note ) Models with a suffix - have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet. Note ) The number of stations that may be displayed is longer than the manifold number of stations. Note ) Specify the wiring specifications by means of the manifold specification sheet. Note ) Indicate for the valve with external pilot. Note) [Option]

27 VQ00- ase Mounted lug-in Unit -VQ000/000 Terminal lock Wiring ( - VQ000) Step. Wiring Loosen screws on the terminal block, connect wiring and complete it by tightening screws. (Tightening torque: 0. to 0.7 N m) The diagram on the right shows the terminal block wiring. ll stations are provided with double wiring regardless of the valves which are mounted. M ound head combination screw pplicable crimped terminal:.-s,.y-,.y-n,.y-. Name plate: VVQ000-N-T Drip proof plug assembly (for G /): XT00-0 How to Order Valve 0 VQ 0 0 VQ000 VQ000 0 Clean series Copper/Fluorine/Silicone free + Low particle generation ctuation type Open the terminal block cover to connect the wires to the terminal block. Step. emoving the terminal block cover Loosen mounting screws ( pcs.) on the terminal block cover and remove the cover. -position single -position double -position closed center -position exhaust center -position pressure center 0 Seal Metal seal ubber seal Caution Use the standard (DC) specification when continuously energizing for long periods of time. Cover Step. Mounting the terminal block cover Securely tighten the screws after confirming that the gasket is installed correctly. (Tightening torque: 0.7 to. N m) Note) For models, DC-type only. Special Wiring Specifications: - VQ000 s the standard electrical wiring specifications, double wiring (connected to SOL. and SOL.) is adopted for the internal wiring of each station for 0 stations or less, regardless of valve and option types. Mixed single and double wiring is available as semi-standard. efer to page for details. Note) When using the negative common specifications, use valves for negative common. efer to Semi-standard on page for details. [Option] Q Note) For models, DC-type only. Enclosure Dust-protected Dust-tight, Water-jet-proof W Note) (I) Note) VQ000 only Manual override Non-locking push type (Tool required) Locking type (Tool required) C Locking type (Manual) D Slide locking type (Manual) Light/surge voltage suppressor E Function Symbol Specifications DC (0. W) Standard High-speed (0.9 W) response type High-pressure type K Note ) (0.9 W) (.0 Ma) Negative N Note ) common External Note ) pilot Yes C Note ) Coil voltage 00 VC (0/0 Hz) 0 VC (0/0 Hz) VDC VDC Station Station Station Station Station Station Station 7 Station 8 Station 9 Station 0 D side U side Terminal no. olarity SOL. (+) SOL. (+) SOL. (+) SOL. (+) SOL. (+) SOL. (+) SOL. (+) SOL. (+) SOL. (+) SOL. (+) SOL. (+) SOL. (+) SOL. 7 (+) SOL. 7 (+) SOL. 8 (+) SOL. 8 (+) SOL. 9 (+) SOL. 9 (+) SOL. 0 (+) SOL. 0 (+) VQ00- VQ00- VQ00- VQ00- VQ00- COM. (+) Note) ositive Negative COM spec. COM spec. How to Order Manifold ssembly Specify the part numbers for valves and options together beneath the manifold base part number. <Example> Terminal block box kit VVQ-08CT0 VQ00- VQ00- VQ00- VVQ000- refix the asterisk to the part no. of the solenoid valve, etc. Note ) efer to page for power consumption of C type. Note ) Metal seal only Note ) efer to Semi-standard on pages to for external pilot and negative common specifications. Note ) When two or more symbols are specified, indicate them alphabetically. Combination of [] and [K] is not possible. set Manifold base part no. sets Valve part no. ( to ) sets Valve part no. ( to ) set Valve part no. (Station 7) set lanking plate part no. (Station 8) Write sequentially from the st station on the D-side. When part no. written collectively are complicated, specify them by means of the manifold specification sheet. 0 Directional Control Valves Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control Flow Control ressure Switches/ ressure Sensors

28 -VQ000/000 T kit (Terminal block box) -VVQ < >: C The dashed lines and dimensions in parentheses indicate DIN rail mounting [-D]. (). <7.> Top entry port Not machined 9 (L) (L) L L = 0. Indicator light 7 (.) Manual override 9. <00.> 0 () (.). x M mounting hole 7 D side DIN rail clamp screw 7 8 n U side C8 [() EXH port] C8: ø8 One-touch fitting G / X X () (7.) C, C, C, M [(), () port] C: ø. One-touch fitting C: ø One-touch fitting C: ø One-touch fitting M: M thread = C8 [() SU port] C8: ø8 One-touch fitting Dimensions L n L L (L) (L) With ejector unit: Formula L = 0.n (Number of ejector units x.7) L = 0.n (Number of ejector units x.7) L is L plus about Formula L = 0.n +., L = 0.n n: Station (Maximum stations)

29 X ase Mounted lug-in Unit -VQ000/000 -VVQ < >: C The dashed lines indicate DIN rail mounting [-D] (with DIN rail mounting bracket). Directional Control Valves. 0 <.9> 80 () 7 (L) (L) L + 0. L Dust-tight, Water-jet-proof.. 0 <.9> x G / Electrical entry. 9. D side EXH (L) (L) L L = 0.9 Indicator light C, C, C8 [(), () port] C: ø One-touch fitting C: ø One-touch fitting C8: ø8 One-touch fitting. x M mounting hole C0 [() EXH port] C0: ø0 One-touch fitting X n EXH = U side (.). Manual override (.) () 0. DIN rail clamp screw. C0 [() SU port] C0: ø0 One-touch fitting (7.) () Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control Dimensions L n L L (L) (L) Formula L = n + 8., L = n + n: Station (Maximum 0 stations) Flow Control ressure Switches/ ressure Sensors

30 -VQ000/000 L kit (Lead wire) I compliant Direct electrical entry. Models with one or more stations are available. SU and EXH ports are provided on one side for further space savings. Maximum stations are 8. Enclosure: Dust-tight, Water-jet-proof (I) compatible ( - VQ000) Wiring Specifications: ositive COM Three lead wires are attached to each station regardless of the type of valve which is mounted. The red wire is for COM connection. SOL. Lead wire color lack SOL. Lead wire color lack - VVQ Manifold Specifications - VQ000 - VQ000 D side U side - VVQ iping specifications iping ort size pplicable stations direction (), () (), () Side Side C8 C0 C, C, C, M C, C8 Max. 8 stations Max. 8 stations COM. (+) ed COM. (+) ed SOL. White SOL. White Single solenoid Double solenoid lack: side solenoid ed: COM (+) Station number Cable cores x WG White: side solenoid (Not used for single solenoid) - VVQ D side U side Use any of the below cable lead wire assembly to change the lead wire length: Lead wire assembly with connector Lead wire length art no. 0. m VVQ m VVQ m VVQ Station number to 8 How to Order Manifold 0 VVQ 0 C L VQ000 VQ000 0 Clean series Copper/Fluorine/Silicone free + Low particle generation Manifold lug-in unit 0 station 08 8 stations Note) For negative common specifications, refer to Semi-standard on page. Cable (Length) 0 Cable length 0. m Cable length. m Cable length m The total number of stations is tabulated on the D-side. Cylinder port Symbol ort size VQ000 VQ000 C Note ) C Note ) C Note ) C8 Note ) M With ø. One-touch fitting With ø One-touch fitting With ø One-touch fitting With ø8 One-touch fitting M thread CM Note ) Note ) Mixed sizes and with port plug MM Note ) Mixed size for different types of piping, option installed Note ) Insert L (Top ported) or (ottom ported) for elbow type. Example) (ottom ported elbow with ø One-touch fitting) Note ) Indicate LM for models with elbow fittings and mixed cylinder port sizes. Note ) Indicate Mixed sizes and with port plug by means of the manifold specification sheet. Note ) When selecting the mixed size for different types of piping, dual flow fitting assembly, or double check block (direct mounting), enter MM and give instructions on the manifold specification sheet. Note ) Inch-size One-touch fittings are available. efer to Semi-standard on page for details. Q Note) For models, DC-type only. Option Symbol D D0 D N W Note ) Note ) Note ) - VVQ Note) For models, DC-type only. Option 00/0 VC models (F/L kit only) With back pressure check valve DIN rail mounting With DIN rail bracket (Without DIN rail) DIN rail length specified ( : 0 to 08) With name plate External pilot Enclosure: Dust-tight, Water-jet-proof (I) [Option] VQ000 VQ000 Note ) When two or more symbols are specified, indicate them alphabetically. Example) -N Note ) Models with a suffix - have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet. Note ) The number of stations that may be displayed is longer than the manifold number of stations. Note ) Indicate for the valve with external pilot.

31 ase Mounted lug-in Unit -VQ000/000 Wiring Specifications: Negative COM (Semi-standard) Three lead wires are attached to each station regardless of the type of valve which is mounted. The black wire is for COM connection. SOL. (+) Lead wire color ed SOL. (+) Lead wire color ed Directional Control Valves How to Order Valve 0 0 VQ 0 0 VQ000 VQ000 ctuation type 0 -position single -position double -position closed center -position exhaust center -position pressure center Seal Metal seal ubber seal Clean series Copper/Fluorine/Silicone free + Low particle generation Function Symbol Specifications DC C (0. W) Standard High-speed (0.9 W) response type High-pressure type K Note ) (0.9 W) (.0 Ma) Negative N Note ) common External Note ) pilot Note ) efer to page for power consumption of C type. Note ) Metal seal only Note ) For external pilot and negative common specifications, refer to Semi-standard on pages to. Note ) When two or more symbols are specified, indicate them alphabetically. Combination of [] and [K] is not possible. -VVQ Dust-tight, Water-jet-proof Note ) Note) For models, DC-type only. Manual override Non-locking push type (Tool required) Locking type (Tool required) C Locking type (Manual) D Slide locking type (Manual) Light/surge voltage suppressor E Yes SOL. (+) Single solenoid COM. lack Station number White Cable cores x WG Lead wire assembly with connector Lead wire length art no. 0. m VVQ000-8N--. m VVQ000-8N-- m VVQ000-8N-0- Station number to 8 Note) When using the negative common specifications, use valves for negative common. For negative common specifications, refer to Semi-standard on page. [Option] Q Note) For models, DC-type only. Enclosure Dust-protected Dust-tight, Water-jet-proof W Note) (I) Note) VQ000 only Coil voltage 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC (0/0 Hz) 0 VC (0/0 Hz) VDC VDC D side U side SOL. (+) White Double solenoid ed: side solenoid (+) VQ00- VQ00- VQ00- VQ00- COM. lack Specify the part numbers for valves and options together beneath the manifold base part number. <Example> Lead wire kit with cable ( m) refix the asterisk to the part no. of the solenoid valve, etc. lack: COM. White: side solenoid (+) (Not used for single solenoid) How to Order Manifold ssembly VVQ-0CL VQ00- VQ00- VQ00- VVQ000- set Manifold base part no. sets Valve part no. ( to ) sets Valve part no. ( to ) set Valve part no. (Station ) set lanking plate part no. (Station ) Write sequentially from the st station on the D-side. When part no. written collectively are complicated, specify them by means of the manifold specification sheet. VVQ000- VQ00- Caution Use the standard (DC) specification when continuously energizing for long periods of time. Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control Flow Control ressure Switches/ ressure Sensors

32 -VQ000/000 L kit (Lead wire) -VVQ < >: C The dashed lines indicate DIN rail mounting [-D] (with DIN rail mounting bracket). (). <7.> 8 (L) (L) L L = 0. Indicator light. (.) Manual override. 9. <00.> Number of stations (.) () 0. Lead wire WG x cores. x M mounting hole D side 7 n U side C8 [() EXH port] C8: ø8 One-touch fitting DIN rail clamp screw X C8 [() SU port] C8: ø8 One-touch fitting 0. = 0. (7.) () C, C, C, M [(), () port] C: ø. One-touch fitting C: ø One-touch fitting C: ø One-touch fitting M: M thread Dimensions L n L L (L) (L) Formula L = 0.n + 8., L = 0.n + 8 n: Station (Maximum 8 stations) With ejector unit: Formula L = 0.n (Number of ejector units x.7) L = 0.n (Number of ejector units x.7) L is L plus about 0.

33 ase Mounted lug-in Unit -VQ000/000 -VVQ () Lead wire WG x cores. Number of 7. <77.> stations 0.9 Dust-tight, Water-jet-proof () 9 0 <.9> C0 [() EXH port] C0: ø0 One-touch fitting.. 9. (7.) C0 [() SU port] C0: ø0 One-touch fitting D side < >: C The dashed lines indicate DIN rail mounting [-D] (with DIN rail mounting bracket). EXH X (L) (L) (.) L L. Manual override Indicator light. C, C, C8 [(), () port] C: ø One-touch fitting C: ø One-touch fitting C8: ø8 One-touch fitting = n (.) x M mounting hole () U side DIN rail clamp screw Directional Control Valves Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control Dimensions L n L L (L) (L) Formula L = n +, L = n + 7 n: Station (Maximum 8 stations) Flow Control ressure Switches/ ressure Sensors

34 -VQ000/000 S kit (Serial transmission) ase mounted plug-in manifold: For EX0 Gateway-type serial transmission system 0 VVQ Manifold series VQ000 VQ000 SI unit specifications NN output (+COM.) Valve stations N N output ( COM.) Symbol 0 station SI unit part no. Symbol SI unit specifications SI unit part no stations N NN output (+COM.) N output ( COM.) EXS00 EXS0 Note) Max. stations. (Special wiring specifications) Cylinder port Symbol ort size VQ000 VQ000 C With ø. One-touch fitting C With ø One-touch fitting C With ø One-touch fitting C8 With ø8 One-touch fitting M M thread CM Note ) With mixed sizes and with port plug L Top ported elbow with ø. One-touch fitting L Top ported elbow with ø One-touch fitting L Top ported elbow with ø One-touch fitting L8 Top ported elbow with ø8 One-touch fitting L Top ported elbow M thread ottom ported elbow with ø. One-touch fitting ottom ported elbow with ø One-touch fitting ottom ported elbow with ø One-touch fitting 8 ottom ported elbow with ø8 One-touch fitting ottom ported elbow M thread LM Note ) Elbow port, mixed sizes N ø/8" with One-touch fitting N ø/" with One-touch fitting N7 ø/" with One-touch fitting N9 ø/" with One-touch fitting MT UNF thread NM Note ) With mixed sizes and with port plug LN Top ported elbow with ø/8" One-touch fitting LN Top ported elbow with ø/" One-touch fitting LN7 Top ported elbow with ø/" One-touch fitting LN9 Top ported elbow with ø/" One-touch fitting LT Top ported elbow UNF thread N ottom ported elbow with ø/8" One-touch fitting N ottom ported elbow with ø/" One-touch fitting N7 ottom ported elbow with ø/" One-touch fitting N9 ottom ported elbow with ø/" One-touch fitting T ottom ported elbow UNF thread LNM Note ) Elbow port, mixed sizes MM Note ) Mixed size for different types of piping, option installed Note ) Indicate Mixed sizes and with port plug in the manifold specification sheet. Note ) When selecting the mixed size for different types of piping, dual flow fitting assembly, or double check block (direct mounting), enter MM and give instructions on the manifold specification sheet. efer to the WE catalog for details on the EX0 gateway-type serial transmission system. 7 Metric size Inch size 0 Clean series Copper/Fluorine/Silicone free + Low particle generation How to Order Manifold S 08 D Q Option Note ) With back pressure check valve D Note ) DIN rail length specified ( : 0 to ) K Note ) Special wiring spec. (Except double wiring) N With name plate Note ) with external pilot Note ) When two or more symbols are specified, indicate them alphabetically. Example) -N Note ) Models with a suffix - have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet. Note ) Specify the wiring specifications by means of the manifold specification sheet. Note ) Indicate for the valve with external pilot. Note ) The number of stations that may be displayed is longer than the manifold number of stations. DIN rail mounting How to Order Manifold ssembly Example D side U side [Option] VVQ-S08C-D set (S kit, 8-station manifold part no.) VQ00- sets (Single type part no.) VQ00- sets (Double type part no.) VQ00- set ( position type part no.) The asterisk denotes the symbol for assembly. refix it to the part no. of the solenoid valve, etc. Enter in order starting from the first station on the D-side. dd the valve and option part numbers under the manifold base part number. For complex arrangements, specify them by means of the manifold specification sheet.

35 ase Mounted lug-in Manifold -VQ000/ Clean series Copper/Fluorine/Silicone free + Low particle generation How to Order Valve VQ 0 0 VQ000 VQ000 ctuation type -position single Metal ubber -position double -position double -position closed center -position exhaust center -position pressure center Manual override : Non-locking push type (Tool required) : Locking type (Tool required) C: Locking type (Manual) D: Slide locking type (Manual) ated voltage VDC Q Function Symbol Specifications Standard (0. W) High-speed response type (0.9 W) K Note ) High-pressure type (.0 Ma) [0.9 W] N Note ) Negative common Note ) External pilot Note ) Metal seal only Note ) For external pilot and negative common specifications, refer to Semi-standard on pages to. Note ) When two or more symbols are specified, indicate them alphabetically. Combination of [] and [K] is not possible. [Option] Directional Control Valves Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control Flow Control Seal 0 Metal seal ubber seal 8 ressure Switches/ ressure Sensors

36 VQ000/000 S kit (Serial transmission) ase mounted plug-in manifold: For EX0 Gateway-type serial transmission system -VVQ pplicable connector: Flat ribbon cable connector (0) (Complies with MIL-C-80) () L L L L (n-) x Indicator light 7 Manual override W COM D side 7 8 n U side C8 [() EXH port] C8: ø8 One-touch fitting DIN rail clamp screw X X 7. C, C, C, M [(), () port] C: ø. One-touch fitting C: ø One-touch fitting C: ø One-touch fitting M: M thread 8. = 0.. C8 [() SU port] C8: ø8 One-touch fitting Dimensions L n L L L L Formula L = 0.n +., L = 0.n + 9 n: Station (Maximum stations)

37 ase Mounted lug-in Manifold -VQ000/000 -VVQ Directional Control Valves pplicable connector: Flat ribbon cable connector (0) (Complies with MIL-C-80) () W COM D side. EXH X L L (.) L L. =. Indicator light 0.9 Manual override 7 8 C, C, C8 [(), () port] C: ø One-touch fitting C: ø One-touch fitting C8: ø8 One-touch fitting C0 [() EXH port] C0: ø0 One-touch fitting X n EXH = U side. 7. DIN rail clamp screw C0 [() SU port] C0: ø0 One-touch fitting Flow Control. 9 Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control Dimensions L n L L L L Formula L = n +, L = n + 0 n: Station (Maximum stations) ressure Switches/ ressure Sensors 0

38 S How to Order Manifold 0 Clean series Copper/Fluorine/Silicone free + Low particle generation VQ000 VQ000 Symbol H Q V Z ZN VVQ 08 C V X 0 Manifold lug-in unit stations Note) stations Note ) efer to page for details. Note ) Max. stations. (Specify a model with 9 to stations by means of the manifold specification sheet.) rotocol NKE Corp.: Fieldbus H System DeviceNet OMON Corp.: Compous/S ( outputs) OMON Corp.: Compous/S (8 outputs) CC-Link -VQ000/000 kit (Serial transmission): For EX0// Integrated-type (Output) serial transmission system I compliant The serial transmission system reduces wiring work, while minimizing wiring and saving space. Enclosure: Dust-tight, Water-jet-proof (I) compatible ( VQ000) 0 Cylinder port Symbol ort size C Note ) With ø. One-touch fitting C Note ) With ø One-touch fitting C Note ) With ø One-touch fitting C8 Note ) With ø8 One-touch fitting M M thread CM Note ) Note ) Mixed sizes and with port plug Mixed size for different types MM Note ) of piping, option installed CompoNet (ositive common) CompoNet (Negative common) S SI unit specifications Symbol rotocol 0 H Q V Z ZN VQ000 VQ000 Without SI unit NKE Corp.: Fieldbus H System DeviceNet OMON Corp.: Compous/S ( outputs) OMON Corp.: Compous/S (8 outputs) CC-Link CompoNet (ositive common) CompoNet (Negative common) SI Unit art No. (Without option W [Dust-protected (-X) is included.]) SI unit part no. Standard: EX0-SUH Dust-protected: EX0-SUH-X Standard: EX0-SDN Dust-protected: No part no. Standard: EX0-SCS Dust-protected: EX0-SCS-X Standard: EX0-SCS Dust-protected: EX0-SCS-X Standard: EX0-SMJ Dust-protected: EX0-SMJ-X Standard: EX0-SCM Dust-protected: No part no. Standard: EX0-SCM Dust-protected: No part no. Note ) Insert L (Top ported) or (ottom ported) for elbow type. Example) (ottom ported elbow with ø One-touch fitting) Note ) Indicate as LM for models with elbow fittings and mixed cylinder port sizes. Note ) Indicate Mixed sizes and with port plug by means of the manifold specification sheet. Note ) When selecting the mixed size for different types of piping, dual flow fitting assembly, or double check block (direct mounting), enter MM and give instructions on the manifold specification sheet. Note ) Inch-size One-touch fittings are available. efer to Semi-standard on page for details. Manifold Specifications - VQ000 - VQ000 Enclosure X Note) Dust-protected Note) efer to SI Unit art No. when ordering the CE-compliant SI unit. Note) Suffix -X for the dust-protected type SI units (Except SI unit specification Q ) Option Symbol Option VQ000 VQ000 Note ) With back pressure check valve Max. D DIN rail mounting stations D Note ) DIN rail mounting ( : 0 to ) Max. 8 stations Special wiring specifications K Note ) (Except double wiring) Max. stations efer to the WE catalog for details on the EX0// integrated-type (Output) serial transmission system. efer to the WE catalog for details on CompoNet. iping specifications iping ort size pplicable stations direction (), () (), () Side C8 C, C, C, M Max. stations Side C0 C, C, C8 Max. stations N Note ) Q Note) efer to SI Unit art No. when ordering the CE-compliant SI unit. With name plate With external pilot [Option] Enclosure: Dust-tight, W Water-jet-proof (I) Note ) When two or more symbols are specified, indicate them alphabetically. Example) -N. Note ) Models with a suffix - have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet. Note ) The number of stations that may be displayed is longer than the manifold number of stations. Note ) Specify the wiring specifications by means of the manifold specification sheet. Note ) Indicate for the valve with external pilot. SI Unit art No. (With option W) Symbol rotocol SI unit part no. H Q V NKE Corp.: Fieldbus H System DeviceNet OMON Corp.: Compous/S ( outputs) OMON Corp.: Compous/S (8 outputs) CC-Link EXD-SUH EXD-SDN EXD-SCS EXD-SCS EXD-SMJ

39 ase Mounted lug-in Unit -VQ000/000 -VVQ How to Order Valve 0 ctuation type 0 -VVQ VQ 0 0 VQ000 VQ000 0 Clean series Copper/Fluorine/Silicone free + Low particle generation -position single -position double -position closed center -position exhaust center -position pressure center Seal Metal seal ubber seal Function Symbol Specifications G / G / prepared hole Enclosure Dust-protected Dust-tight, Water-jet-proof W Note) (I) Note) - VQ000 only Manual override Non-locking push type (Tool required) Locking type (Tool required) C Locking type (Manual) D Slide locking type (Manual) Coil voltage VDC With indicator light/ surge voltage suppressor Standard -VVQ Dust-protected (-X) DC (0. W) High-speed (0.9 W) response type Highpressure type K Note ) (0.9 W) (.0 Ma) Negative N Note ) common Note ) External pilot Note ) Metal seal only Note ) For external pilot and negative common specifications, refer to Semi-standard on pages to. Note ) When two or more symbols are specified, indicate them alphabetically. Combination of [] and [K] is not possible. Q [Option] -VVQ Dust-tight, Water-jet-proof (-W) How to Order Manifold ssembly Specify the part numbers for valves and options together beneath the manifold base part number. <Example> VVQ-08CSV VQ00- VQ00- VQ00- VVQ000- refix the asterisk to the part no. of the solenoid valve, etc. D side U side VQ00- VQ00- VQ00- set Manifold base part no. sets Valve part no. ( to ) sets Valve part no. ( to ) set Valve part no. (Station 7) set lanking plate part no. (Station 8) VVQ000- VQ00- VQ00- VQ00- VQ00- Write sequentially from the st station on the D-side. When part no. written collectively are complicated, specify them by means of the manifold specification sheet. Directional Control Valves Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control Flow Control ressure Switches/ ressure Sensors

40 VQ000/000 S kit (Serial transmission): For EX0 Integrated-type (Output) serial transmission system -VVQ. L7 L L (L) 8 (n-) x 0. The dashed lines indicate DIN rail mounting [-D] (with DIN rail mounting bracket). SMC V 9. Drawing shows a SC case. (general purpose type) 0V FG S E I L U N I T MODEL SC (SI No.EX0-ST) UN T/ E D I S W. Dust-protected SI unit ()... 8 (L) (L) L L (n-) x (.) Indicator light Manual override SMC V V FG S E I L U N I T MODEL SC (SI No.EX0-ST) UN T/ E D I S W. Drawing shows a SC case. (.) X X () () x M mounting hole D side 7 8 n U side C8 [() EXH port] C8: ø8 One-touch fitting DIN rail clamp screw (7.) C, C, C, M [(), () port] C: ø. One-touch fitting C: ø One-touch fitting C: ø One-touch fitting M: M thread 8 = 0.. C8 [() SU port] C8: ø8 One-touch fitting Dimensions L n L L (L) (L) Dust-protected SI unit: L = 0.n + 97, L = L +, L7 = L + Formula L = 0.n +., L = 0.n + 7. n: Station (Maximum stations)

41 0V FG 0 0V FG 0 S E I L U N I T x x 0 D SD STTION NO. ase Mounted lug-in Unit -VQ000/000 -VVQ L7 = L + L = L + L = n + 08 L. (n-) x The dashed lines indicate DIN rail mounting [-D] (with DIN rail mounting bracket). 8 L = L + 0 L0 = L + 0 L9 = n + Directional Control Valves () 7. V SMC S E I L U N I T MODEL SC UN T/ E Drawing shows a SC case. Dust-protected SI unit D side EX : x G/ EX : x G/ Electrical entry Use a drip proof plug ass y (XT00-0) on the unused conduit port (G/). V S E I L U N I T MODEL SC SMC UN T/ E (L) (L) (.) L L. (n-) x.. = 0.9 Indicator light Manual override Drawing shows a SC case. 7 8 EXH X X n EXH MODEL S 00 L8 = n + 8. Dust-tight, Water-jet-proof (I) SI unit (EX/ Integrated-type (output) serial transmission system) U side (.) () x M mounting hole C0 [() EXH port] C0: ø0 One-touch fitting DIN rail clamp screw. 9 Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control Dimensions L n L L (L) (L) () (7.) C, C, C8 [(), () port] C: ø One-touch fitting C: ø One-touch fitting C8: ø8 One-touch fitting = C0 [() SU port] C0: ø0 One-touch fitting Dust-protected SI unit: L = n + 08, L = L +, L7 = L + Dust-tight, Water-jet-proof SI unit: L8 = n + 8., L9 = n + L0 = L + 0, L = L + 0 Formula L = n +, L = n + 8 n: Station (Maximum stations) Flow Control ressure Switches/ ressure Sensors

42 S VQ000 only -VQ000 kit (Serial transmission): For EX0 Integrated-type (I/O) serial transmission system I compliant The serial transmission system reduces wiring work, while minimizing wiring and saving space. How to Order Manifold 0 0 VQ000 lug-in series 0 station stations Cylinder port Symbol ort size C Note ) With ø One-touch fitting C Note ) With ø One-touch fitting C8 Note ) With ø8 One-touch fitting CM Note ) Note ) Mixed sizes and with port plug MM Note ) Mixed size for different types of piping, option installed SI unit mounting D: D side mounting Note ) Insert L (Top ported) or (ottom ported) for elbow type. Example) (ottom ported elbow with ø one-touch fitting) Note ) Indicate LM for models with elbow fittings and mixed cylinder port sizes. Note ) Indicate Mixed sizes and with port plug by means of the manifold specification sheet. Note ) When selecting the mixed size for different types of piping, dual flow fitting assembly, or double check block (direct mounting), enter MM and give instructions on the manifold specification sheet. Note ) Inch-size One-touch fittings are available. efer to Semi-standard on page for details. efer to the WE catalog for details on the EX0 integrated-type (I/O) serial transmission system. How to Order Manifold 0 VVQ 08 C D QW N W Clean series Copper/Fluorine/Silicone free + Low particle generation Seal 0 Metal seal ubber seal Note) For external pilot and negative common specifications, refer to Semi-standard on pages to. Model 0W QW NWN VQ 0 0 W 0 Clean series Copper/Fluorine/Silicone free + Low particle generation ctuation type -position single -position double -position closed center -position exhaust center -position pressure center Function Symbol Specifications K N S Standard High-speed response type Note ) High-pressure type (.0 Ma) Note ) Negative common Note ) External pilot 0 N Without SI unit DeviceNet OFIUS-D Enclosure I (Dust-tight, Water-jet-proof) Option Symbol K N Note) When two or more symbols are specified, indicate them alphabetically. Example: -N Input block type N sensor input (+COM) or without SI unit/input block NN sensor input ( COM) Number of input blocks Without SI unit Without input block With pc. input block With pcs. input blocks With pcs. input blocks With pcs. input blocks +COM. COM. Enclosure I (Dust-tight, Water-jet-proof) Manual override Non-locking push type (Tool required) Locking type (Tool required) C Locking type (Manual) D Slide locking type (Manual) Coil voltage DC (0. W) (0.9 W) (0.9 W) [Option] Q Option With back pressure check valve Special wiring spec. (Except double wiring) With name plate External pilot Note) Only +COM is available for DeviceNet. Order a mounting valve with +COM. Since OFIUS is COM only, order COM for valves to be mounted. VDC, With indicator light/surge voltage suppressor Note ) Metal seal only Note ) For external pilot and negative common specifications, refer to Semi-standard on pages to. Note ) When a valve is compatible with OFIUS D, the SI unit is negative common. Select valves for negative common. Note ) When two or more symbols are specified, indicate them alphabetically. Combination of [] and [K] is not possible. Q efer to SI Unit art No. when ordering the CE-compliant SI unit. Caution Use the standard (DC) specification when continuously energizing for long periods of time.

43 ase Mounted lug-in Unit -VQ000 -VVQ (Serial transmission kit: EX0) Directional Control Valves L (In case of pc. input block: 8 number of inputs) 8. () L 0 If the input block is attached, it comes with a bracket. Min. 0 to Max. unit (0 to mm) Input block D side = Manual override Indicator light x M mounting hole 7 C0 [() EXH port] C0: ø0 One-touch fitting C, C, C8 [(), () port] C: ø One-touch fitting C: ø One-touch fitting C8: ø8 One-touch fitting = 8 X n EXH U side 9... C0 [() SU port] C0: ø0 One-touch fitting Formula L = n +. L = n + 8 (In case of pc. DI unit, mm will be added for increasing every pc.) Dimensions n: Station (Maximum stations) L n L L Flow Control ir reparation ressure Control Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ressure Switches/ ressure Sensors

44 -VQ000 M kit (Circular connector) MIL flat cable connector reduces installation labor for electrical connection. Manifold and connectors, both compliant with the I rating (Dust-tight, Water-jet-proof), provide a high-degree of protection for the electrical parts. Maximum stations are. Circular Connector ( ins) Manifold Specifications - VQ000 iping direction Side -VVQ iping specifications (), () C0 ort size (), () C, C, M8 VQ000 only pplicable stations Max. stations XT00-MC Circular connector cable assembly included in a specific manifold model no. efer to How to Order Manifold. L Multi-core vinyl cable 0. mm x cores ø0 lug terminal no. Socket side Circular connector cable assembly Cable length ssembly part no. (L). m m m XT00-MC-0 XT00-MC-00 XT00-MC-00 Cannot be used for transfer wiring. Note) Lengths other than the above are also available. lease contact SMC for details. Note Cable -core x WG Electrical characteristics Item roperty Conductor resistance Ω/km, 0 C or less Voltage limit V, minute, C 000 Insulation resistance MΩ/km, 0 C or more Note) The minimum bending radius of the circular connector cable is 0 mm. Circular connector cable assembly terminal no. Terminal no. Lead wire color Dot marking Cable ssembly lack rown ed Orange Yellow ink lue urple Gray White White Yellow Orange Yellow ink lue urple Gray Orange ed rown ink Gray lack White White White lack lack ed ed ed lack lack White lack White White ed ed White How to Order Manifold 0 0 Clean series Copper/Fluorine/Silicone free + Low particle generation 0 stations VVQ 08 C N VQ000 Manifold lug-in unit stations Note) efer to page for details. 7 M Cylinder port Symbol ort size C Note ) With ø One-touch fitting C Note ) With ø One-touch fitting C8 Note ) With ø8 One-touch fitting CM Note ) Note ) Mixed sizes and with port plug MM Note ) Mixed size for different types of piping, option installed Note ) Insert L (Top ported) or (ottom ported) for elbow type. Example) (ottom ported elbow with ø One-touch fitting) Note ) Indicate LM for models with elbow fittings and mixed cylinder port sizes. Note ) Indicate Mixed sizes and with port plug by means of the manifold specification sheet. Note ) When selecting the mixed size for different types of piping, dual flow fitting assembly, or double check block (direct mounting), enter MM and give instructions on the manifold specification sheet. Note ) Inch-size One-touch fittings are available. efer to Semi-standard on page for details. Cable (Length) 0 Without cable With cable (. m) With cable ( m) With cable ( m) Option Symbol Note ) D D0 D K N W Note ) Note ) Note ) Note) For models, DC-type only. [Option] Note) For Q models, DC-type only. Option With back pressure check valve DIN rail mounting With DIN rail bracket (Without DIN rail) DIN rail mounting ( : 0 to ) Special wiring spec. (Except double wiring) With name plate External pilot Enclosure: Dust-tight, Water-jet-proof (I) Note ) When two or more symbols are specified, indicate them alphabetically. Example) -K Note ) Models with a suffix - have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet. Note ) The number of stations that may be displayed is longer than the manifold number of stations. Note ) Specify the wiring specifications by means of the manifold specification sheet. Note ) Indicate for the valve with external pilot.

45 ase Mounted lug-in Unit -VQ000 Directional Control Valves 0 The total number of stations is tabulated starting from station one on the D-side. How to Order Valve 0 D side ctuation type -position single -position double -position closed center -position exhaust center -position pressure center Seal Metal seal ubber seal VQ 0 0 VQ000 0 Clean series Copper/Fluorine/Silicone free + Low particle generation U side Caution Use the standard (DC) specification when continuously energizing for long periods of time. -VVQ Function Symbol Specifications DC (0. W) Standard High-speed (0.9 W) response type High-pressure type K Note ) (0.9 W) (.0 Ma) Negative N Note ) common External Note ) pilot Note ) For power consumption of C type, refer to page. Note ) Metal seal only Note ) For external pilot and negative common specifications, refer to Semi-standard on pages to. Note ) When two or more symbols are specified, indicate them alphabetically. Combination of [] and [K] is not possible. Electrical Wiring Specifications Manual override C D 9 8 Station Station Station Station Station Station Station 7 Station 8 s the standard electrical wiring specifications, double wiring (connected Station 9 to SOL. and SOL.) is adopted for Station 0 the internal wiring of each station for stations or less, regardless of Station valve and option types. Mixed single and double wiring is Station available as semi-standard. efer to (Max.) page for details. Note) When using the negative common specifications, use valves for negative common. (efer to page.) efer to Semi-standard on page for details. Note) For models, DC-type only. C Note ) W Q Note) For models, DC-type only. Enclosure Non-locking push type (Tool required) Locking type (Tool required) Locking type (Manual) Slide locking type (Manual) Light/surge voltage suppressor Yes E Coil voltage 00 VC (0/0 Hz) 0 VC (0/0 Hz) VDC VDC [Option] Dust-protected Dust-tight, Water-jet-proof (I) Circular connector cable assembly 0 XT00-MC-00 Wire color 00 Terminal no. olarity Lead wire color Dot marking SOL. (+) lack SOL. (+) rown SOL. (+) ed SOL. (+) Orange SOL. (+) Yellow SOL. (+) ink SOL. 7 (+) lue SOL. 8 (+) urple White SOL. 9 (+) Gray lack SOL. 0 (+) White lack SOL. (+) White ed SOL. (+) Yellow ed SOL. (+) Orange ed SOL. (+) Yellow lack SOL. (+) ink lack SOL. (+) lue White SOL. 7 (+) urple SOL. 8 (+) Gray SOL. 9 (+) Orange lack SOL. 0 (+) ed White SOL. (+) rown White SOL. (+) ink ed SOL. (+) Gray ed SOL. (+) lack White COM. (+) Note) White COM. (+) White m ositive COM spec. Negative COM spec. How to Order Manifold ssembly Specify the part numbers for valves and options together beneath the manifold base part number. <Example> Circular connector kit with cable ( m) VVQ-09CM-W VQ00- VQ00- VQ00- VVQ000- refix the asterisk to the part no. of the solenoid valve, etc. set Manifold base part no. sets Valve part no. ( to ) sets Valve part no. ( to ) sets Valve part no. ( 7 to 8) set lanking plate part no. (Station 9) Write sequentially from the st station on the D-side. When part no. written collectively are complicated, specify them by means of the manifold specification sheet. D side U side 8 Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control Flow Control ressure Switches/ ressure Sensors

46 -VQ000 M kit (Circular connector) -VVQ < >: C The dashed lines and dimensions in parentheses indicate DIN rail mounting [-D]. (L) Made by CONINVES GmbH HC-NWF00 7. <77.> (L) (.) L L Indicator light Manual override.. x M mounting hole () <.9> (.) () D side 7 8 n U side C0 [() EXH port] C0: ø0 One-touch fitting C0 [() SU port] C0: ø0 One-touch fitting EXH EXH DIN rail clamp screw () 9.. X X 9. 7 C, C, C8 [(), () port] C: ø One-touch fitting C: ø One-touch fitting C8: ø8 One-touch fitting = (7.) Dimensions L n L L (L) (L) Formula L = n + 77., L = n n: Station (Maximum stations)

47 VQ000 - Sub-plate Single Unit How to Order Note) For models, DC-type only. [Option] Directional Control Valves I enclosure in standard specifications Easy-to-use terminal block Terminal block Dimensions x ø. (Mounting hole) Manual override Indicator light 7.7 <7.7> ( port) 89. VQ0 0 - <7.9> In the case of In the case of (.8) 0. ( port) 7 Valve Sub-plate VQ 0 0 W 0 Entry is the same as standard products. 0 Clean series Copper/Fluorine/Silicone free + Low particle generation Enclosure Dust-protected W Note ) I (Dust-tight, Water-jet-proof) Note ) Valves are I specifications. Note ) When the valve is a standard (dust-protected) specification, it is not compatible with 00 or 0 VC. VQ000 Sub-plate W 0 alone ort size 0 /.. X Q Note) For models, DC-type only. Thread type c N NT T NTF F G Clamp screw M x 0.8 External pilot port 0 (, port) Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control Flow Control G /8 Electrical entry < >: C Note) When using this valve for I, mount a seal connector to the electrical entry.. x /" (), (), (), (), () port 0 ressure Switches/ ressure Sensors

48 -VQ000/000 Semi-standard Different Number of Connector ins F and kits with the following number of pins are available besides the standard number (F = ; = ). Select the desired number of pins and cable length from the cable assembly list. lace an order for the cable assembly separately. F kit (D-sub connector) pins kit (Flat ribbon cable) 0//0 pins How to Order Manifold -VVQ 0 C F S How to Order Manifold -VVQ 0 C SC Option Option Cylinder port Cylinder port How to Order D-sub connector, pins Connector location Side Without cable Kit type/electrical entry Kit type/electrical entry Location ins Top entry Side entry Location ins Top entry (Max. 7 stations) F kit U F kit S 0 (Max. stations) In the same way as the -pin models (standard), the terminal no. is for (Max. 7 stations) kit SOL. at the st station, the terminal no. 9 for SOL. at the st station, and 0 (Max. 9 stations) the terminal no. 8 for COM. D-sub Connector Cable ssembly Wire Color Table by Terminal No. of D-sub Connector Cable ssembly Terminal no. Lead wire color Cable length (L). m m m ins XT00-DS- XT00-DS- XT00-DS- For other commercial connectors, use a type conforming to MIL-C-08. Multi-core vinyl cable VVF 0. mm x cores ø9 lug connector HD-CTH (Made by Hirose Electric) Connector HD-S (Made by Hirose Electric) x M. x 0. Terminal no lack rown ed Orange Yellow ink lue urple Gray White White Yellow Orange Yellow ink Dot marking White lack lack ed ed ed lack lack U U UC Flat ibbon Cable ssembly How to Order Flat ribbon cable, 0 pins Connector location Side Without cable kit Side entry S S SC In the same way as the -pin models (standard), the terminal no. is for SOL. at the st station, the terminal no. for SOL. at the st station, and two pins from the max. terminal numbers are for COM. Terminal no. Cable length (L) ins 0 0. m m m XT00-FC XT00-FC XT00-FC XT00-FC- XT00-FC- XT00-FC- XT00-FC0- XT00-FC0- XT00-FC0- Connector width (W) For other commercial connectors, use a type with strain relief conforming to MIL-C-80. ed

49 ase Mounted lug-in Unit -VQ000/000 Special Wiring Specifications In the internal wiring of F//J/G/T/S kit, double wiring (connected to SOL. and SOL.) is adopted for each station regardless of the valve and option types. Mixed single and double wiring is available as an option.. How to Order Indicate an option symbol -K, for the manifold no. and be sure to specify the mounting position and number of stations of the single and double wiring by means of the manifold specification sheet. -VVQ 08CFU D K S Others, option symbols: to be indicated alphabetically.. Wiring specifications With the side solenoid of the st station as no. (meaning, to be connected to no. terminal), without making any terminals vacant. F kit D-sub connector () F kit (D-sub Kit connector) U F Type S U U F S S Max. points Kit Type -VQ000 Max. points -VQ000 kit Flat ribbon cable connector () kit (Flat ribbon cable) T kit (Terminal block box) U U S C S U S 0 0 G kit (Flat ribbon cable with terminal block) S kit M kit (Serial transmission) (Circular connector) S G 8 8 rows of terminal blocks J/G kit rows of terminal blocks 0 rd row nd row st row T kit T kit Terminal block Terminal block (VQ000, terminals) (VQ000). Max. number of stations The maximum number of stations depends upon the number of solenoids. ssuming one for a single and two for a double, determine the number of stations so that the total number is not more than the max. number given in the following table. J kit (Flat ribbon cable) J U S M 0 8 M kit COM. Negative Common Specifications Specify the valve model no. as shown below for negative common specification. The manifold no. shown below is for the T (VQ000) and L (VQ000/000) kits. For other kits the standard manifold can be used. However, negative common is not compatible with S (except EX0 gateway-type, EX0 integrated-type and EX0/ / integrated-type (CompoNet )) and G kits. How to Order Valve -VQ00 N How to Order Manifold T kit (VQ000): -VVQ L kit (VQ000/000): -VVQ - - Negative common specifications 0 0 Cylinder port C T N Cylinder port Option Negative common specifications C L N Negative common specifications Electrical entry Cable length 0 With cable (0. m) With cable (. m) With cable ( m) Option Directional Control Valves Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control Flow Control ressure Switches/ ressure Sensors

50 -VQ000/000 Semi-standard External ilot Specifications When the supply air pressure is lower than the required minimum operating pressure (0. to 0. Ma) for the solenoid valve (or when the valve is used for vacuum), specify an external pilot model. Order a manifold or valve by suffixing the external pilot specification,. The X-port of the manifold base is equipped with One-touch fittings for external pilot. VQ000: C (ø One-touch fitting) VQ000: C (ø One-touch fitting) How to Order Manifold -VVQ 08CFU S -VQ00 External pilot specifications How to Order Valve Others, option symbols: to be indicated alphabetically. External pilot specifications Note ) When two or more functions are specified, indicate them alphabetically. Note ) Since the pilot EXH of this valve is released from the passage, it is not possible to vacuum from a part other than EXH pressure and SU ports. Inch-size One-touch Fittings The valve with inch-size One-touch fittings is shown below. -VVQ 0 N7 S0 Option Kit type/electrical entry Cylinder port Symbol N N N7 N9 MT NM UNF pplicable tubing O.D. (Inch) ø/8" ø/" ø/" ø/" (M thread) Mixed (), () VQ000 port VQ000 Note) When inch-size fittings are selected for the cylinder port, inch-size fittings are selected on (), () port, too. DIN ail Mounting Each manifold can be mounted on a DIN rail. Order it by indicating a DIN rail mounting option symbol, -D. In this case, a DIN rail which is approx. 0 mm longer than the manifold with the specified number of stations is attached. When DIN rail is unnecessary (DIN rail mounting brackets only are attached.) Indicate the option symbol, -D0, for the manifold part number. How to Order Manifold -VVQ 08CFU D0S How to Order Manifold Others, option symbols: to be indicated alphabetically. When using DIN rail longer than the manifold with specified number of stations Clearly indicate the necessary number of stations next to the option symbol -D for the manifold part number. -VVQ 08CFU D09S Others, option symbols: to be indicated alphabetically. The number of stations that may be displayed is longer than the manifold number of stations. No. VVQ000-7 (For VQ000) VVQ000-7 (For VQ000) pcs. per one set. DIN rail for 9 stations When changing to a DIN rail mounting. Order brackets for mounting a DIN rail. (efer to Manifold Optional arts on pages 7 and 7.) When ordering DIN rail only DIN rail no.: XT00-D- s for, specify the number from the DIN rail table. efer to the dimensions of each kit for L dimension. (itch) (), () port size VQ000 ø/" (N9) VQ000 ø/8" (N) L Dimension L =. x n + 0. No L dimension No. L dimension No. L dimension No. L dimension

51 Metal seal -VQ000/000 Construction -VQ000 lug-in Unit: Main arts/eplacement arts e q w ubber seal e q w Directional Control Valves r r r -VQ00 ()() ()()() -VQ00 ()() ()()() -VQ00 ()() ()()() -VQ00 ()() Component arts No. Description ody Spool/Sleeve iston ilot valve assembly e q w e q w ()()() Material Zinc die-casted Stainless steel esin -VQ00 ()() ()()() Note) efer to page 8 for How to Order ilot Valve ssembly. Note r r r -VQ0 () () ()()() e q w -VQ0 () () e q ()()() -VQ0 ()() ()()() -VQ0 ()() Component arts No. Description ody Spool valve iston ilot valve assembly ()()() w Material Zinc die-casted luminum, HN esin -VQ0 ()() ()()() Note) efer to page 8 for How to Order ilot Valve ssembly. Note ir reparation Flow Control ressure Control Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ressure Switches/ ressure Sensors

52 -VQ000/000 -VQ000 lug-in Unit: Main arts/eplacement arts Metal seal ubber seal e q w e q w r -VQ00 ()() r -VQ0 () () ()()() ()()() e q w e q w -VQ00 ()() -VQ0 () () r ()()() e q w r ()()() e q w -VQ00 ()() -VQ00 ()() -VQ0 ()() -VQ0 ()() r ()()() -VQ00 ()() ()()() r ()()() -VQ0 ()() ()()() ()()() ()()() Component arts No. Description ody Spool/Sleeve iston ilot valve assembly Material Zinc die-casted Stainless steel esin Note) efer to page 8 for How to Order ilot Valve ssembly. Note Component arts No. Description ody Spool valve iston ilot valve assembly Material Zinc die-casted luminum, HN esin Note) efer to page 8 for How to Order ilot Valve ssembly. Note

53 Flow Control ressure Control ir reparation Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders Directional Control Valves ressure Switches/ ressure Sensors

54 Exploded View of Manifold -VQ000 lug-in Unit: Exploded View (F//J/L/S kit) Housing assembly, SI unit, D-side end plate assembly r Manifold block assembly U-side end plate assembly S kit q r y /J kit! i w r!0 o! pins (Top entry) (Integrated housing)!! F kit pins (Upward side entry) pins (Side entry) r! e u L kit t 7

55 Exploded View of Manifold <Housing ssembly and SI Unit> Housing assembly and SI unit no. No. Manifold art no. Description q (SH kit) (SQ kit) (S kit) (S kit) (SV kit) (SZ kit) (SZN kit) EX0-SUH(-X) Note ) EX0-SDN EX0-SCS(-X) Note ) EX0-SCS(-X) Note ) EX0-SMJ(-X) Note ) EX0-SCM EX0-SCM NKE Corp.: Fieldbus H System ( outputs) DeviceNet OMON Corp.: Compous/S ( outputs) OMON Corp.: Compous/S (8 outputs) CC-Link CompoNet (ositive common) CompoNet (Negative common) w e U S kit FU kit U XT00-- Note ) S XT00--FU Flat ribbon cable housing assembly = Number of pins: /0//0 D-sub connector housing assembly (Top entry) Number of pins: U J S kit FS kit U XT00--J 0 Note ) S XT00--FS Flat ribbon cable housing assembly D-sub connector housing assembly (Side entry) = Number of pins: / Note ) Top entry connector for U, JU while side entry connector for S, JS. Note ) Suffix -X to the end of the part number for dust-protected SI unit. (Not available for S/SQ kit) <D-Side End late ssembly> rt D-side end plate assembly no. VVQ Electrical entry Option FU F J L S For F kit top entry pins For F kit other than above For kit For J kit For L kit For S kit Note ) S Note ) <Manifold lock ssembly> i Manifold block assembly no. VVQ Electrical entry F0 Without lead wire F F kit for to stations/double wiring F F kit for to stations/double wiring F F kit for to stations/single wiring /J/S kit for to stations/double wiring /J/S kit for to stations/double wiring /J/S kit for to stations/single wiring L0 L0 kit : ( to 8) L L kit : ( to 8) L L kit : ( to 8) <eplacement arts for Manifold lock> eplacement arts VVQ No. art no. Description Material Quantity o!0!! VVQ VVQ VVQ VVQ Gasket Seal Clamp screw Clip HN HN Carbon steel Stainless steel Note) set of parts containing pcs. each is enclosed. Common EXH External pilot Direct EXH outlet with built-in silencer Note ) When both options are specified, indicate as S. Note ) The housing assembly and SI unit of F//J/S kit are not included (except FU). Separately place an order for q, w, e. Tie-rod ( pcs.) and lead wire assembly for extensions are attached. ort size C C C M C0 With ø. One-touch fitting With ø One-touch fitting With ø One-touch fitting M thread Without One-touch fitting (With clip) u U-side end plate assembly no. (For L kit) VVQ000---L <Fitting ssembly>! Fitting assembly part no. (For cylinder port) <U-Side End late ssembly> y U-side end plate assembly no. (For F//J/S kit) VVQ Option Note) urchase orders are available in units of 0 pieces. ort size C pplicable tubing ø. C pplicable tubing ø C pplicable tubing ø M M thread! Fitting assembly part no. (For (), () port) VVQ000--C8 pplicable tubing ø8 Note) urchase orders are available in units of 0 pieces.! Tie-rod assembly part no. ( pcs./set) Note ) efer to page for power consumption of C type. Note ) Common to single solenoid and double solenoid Common EXH External pilot S Direct EXH outlet with built-in silencer Note) The! s fitting assembly is included. VVQ000-T- Note ) lease order when eliminating manifold stations. When adding stations, tie-rods are attached to the manifold block assembly. Therefore, it is not necessary to order. Note ) : 0 to Note ) For S//J/F/L kit ilot valve assembly -V - Enclosure Function Coil voltage Dust-tight, Symbol Specifications DC C 00 VC (0/0 Hz) Water-jet-proof (0. W) Note ) 00 VC (0/0 Hz) (I) Standard 0 VC (0/0 Hz) Dust-protected High-speed (0.9 W) 0 VC (0/0 Hz) response type VDC High-pressure type (0.9 W) VDC K (.0 Ma) 8 Directional Control Valves Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control Flow Control ressure Switches/ ressure Sensors

56 Exploded View of Manifold -VQ000 lug-in Unit: Exploded View (F//J/L/G/S kit) Housing assembly and SI unit D-side end plate assembly Manifold block assembly U-side end plate assembly q!0! o /J kit u w!!! F kit t!! e G kit S kit r i L kit y 9

57 Exploded View of Manifold <Housing ssembly and SI Unit> Housing assembly and SI unit no. No. Manifold art no. Description q (SH kit) (SQ kit) (S kit) (S kit) (SV kit) (SZ kit) (SZN kit) EX0-SUH(-X) Note ) [EXD-SUH] Note ) EX0-SDN [EXD-SDN] Note ) EX0-SCS(-X) Note ) [EXD-SCS] Note ) EX0-SCS(-X) Note ) [EXD-SCS] Note ) EX0-SMJ(-X) Note ) [EXD-SMJ] Note ) EX0-SCM EX0-SCM NKE Corp.: Fieldbus H System ( outputs) DeviceNet OMON Corp.: Compous/S ( outputs) OMON Corp.: Compous/S (8 outputs) CC-Link CompoNet (ositive common) CompoNet (Negative common) U U kit Flat ribbon cable housing assembly : Number of pins: /0//0 w S XT00-- Note ) S U U J S kit XT00--J 0 Note ) S Flat ribbon cable housing assembly e r U F S kit G kit U XT00--F Note ) S XT00--GU0 D-sub connector housing assembly : Number of pins: / Flat ribbon cable housing assembly with terminal block Note ) Suffix -X to the end of the part number for dust-protected SI unit. Note ) Dust-tight, Water-jet-proof (I) Note ) Top entry connector for FU, U, JU while side entry connector for FS, S, JS. <D-Side End late ssembly> ty D-side end plate assembly no. VVQ Electrical entry Enclosure F J L G S For F kit For kit For J kit For L kit For G kit For S kit W Dust-protected Dust-tight, Water-jet-proof (I) Option Common EXH Note ) External pilot S Note ) Direct EXH outlet with built-in silencer Note ) When both options are specified, indicate as S. Note ) The housing assembly and SI unit of F//J/G/S kit are not included. Separately place an order for q, w, e, r. Note ) S (uilt-in silencer) and W (I) cannot be combined. <Manifold lock ssembly> o Manifold block assembly no. VVQ Electrical entry F0 Without lead wire F F kit for to stations/double wiring F F kit for to stations/double wiring F F kit for to stations/single wiring /J/G/S kit for to stations/double wiring /J/G/S kit for to stations/double wiring /J/G/S kit for to stations/single wiring L0 L0 kit : ( to 8) L L kit : ( to 8) L L kit : ( to 8) T T kit for to 0 stations/double wiring T T kit for to 0 stations/single wiring M M kit for to stations/double wiring M M kit for to stations/double wiring M M kit for to stations/single wiring Note) F//J/G kit are available with only. M kit is available with [W] only. S/L/T kit are selectable depending on the manifold type. Tie-rod ( pcs.) and lead wire assembly for extensions are attached. ort size C C C8 C0 <eplacement arts for Manifold lock> eplacement arts No. art no. Description Material Quantity!0!!! VVQ VVQ VVQ VVQ Gasket Seal Clamp screw Clip HN HN Carbon steel Stainless steel Note) set of parts containing pcs. each is enclosed.! Tie-rod assembly part no. ( pcs./set) VVQ000-T- Note ) lease order when eliminating manifold stations. When adding stations, tie-rods are attached to the manifold block assembly. Therefore, it is not necessary to order. Note ) : 0 to Note ) For S//J/F/L kit <U-Side End late ssembly> u U-side end plate assembly no. (For F//J/G/T/S/M kit) VVQ Option Enclosure S With ø One-touch fitting With ø One-touch fitting With ø8 One-touch fitting Without One-touch fitting (With clip) Common EXH External pilot Direct EXH outlet with built-in silencer W Note ) The! s fitting assembly is included. Note ) The housing assembly and SI unit of F//J/G/S kit are not included. Separately place an order for q, w, e, r. Note ) S (uilt-in silencer) and W (I) cannot be combined. Note) urchase orders are available in units of 0 pieces. Dust-protected Dust-tight, Water-jet-proof (I) Note) F//J/G kit are available with only. M kit is available with [W] only. S/T kit are selectable depending on the manifold type. i U-side end plate assembly no. (For L kit) VVQ L- Enclosure Dust-protected W Dust-tight, Water-jet-proof (I) Note) Select it depending on the manifold type. Enclosure Dust-protected W Dust-tight, Water-jet-proof (I) Note) F//J/G kit are available with only. M kit is available with [W] only. S/L/T kit are selectable depending on the manifold type. C C C8 pplicable tubing ø pplicable tubing ø pplicable tubing ø8! Fitting assembly part no. (For (), () port) VVQ000--C0 pplicable tubing ø0 Note) urchase orders are available in units of 0 pieces. <Fitting ssembly>! Fitting assembly part no. (For cylinder port) VVQ000-- ort size 70 Directional Control Valves Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control Flow Control ressure Switches/ ressure Sensors

58 -VQ000 -VQ000: Manifold Optional arts lanking plate assembly VVQ000- Symbol It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. Individual SU spacer C VVQ N7 When the same manifold is to be used for different pressures, individual SU spacers are used as SU ports for different pressures. (One station space is occupied.) lock both sides of the station, for which the supply pressure from the individual SU spacer is used, with SU block plates. (efer to the application example.) Specify the spacer mounting position and SU block plate position by means of the manifold specification sheet. The block plate is used in one or two places for one set. (Two SU block plates for blocking SU station are attached to the individual SU spacer.) s a standard, electric wiring is connected to the position of the manifold station where the individual SU spacer is mounted. If wiring is not required for stations equipped with spacers, enter X in the special wiring specifications column in the manifold specification sheet. SU block plate D side Individual SU spacer C (SU port) C: ø One-touch fitting lock indication label label indicating the SU passage blocking position is to be adhered. U side D side SU block plate SU block plate Valve Individual Valve Valve SU spacer U side Individual EXH spacer VVQ C N7 When valve exhaust affects other stations due to the circuit configuration, this spacer is used for individual valve exhaust. (One station space is occupied.) lock both sides of the individual valve EXH station. (efer to the application example.) Specify the mounting position, as well as the EXH block base or EXH block plate position by means of the manifold specification sheet. The block plate is used in one or two places for one set. n EXH block base assembly is used in the blocking position when ordering an EXH spacer incorporated with a manifold no. However, do not order an EXH block base assembly because it is attached to the spacer. When separately ordering an individual EXH spacer, separately order an EXH block base assembly because it is not attached to the spacer. s a standard, electric wiring is connected to the position of the manifold station where the individual EXH spacer is mounted. If wiring is not required for stations equipped with spacers, enter X in the special wiring specifications column in the manifold specification sheet. SU block plate VVQ000- When different pressures are supplied to a manifold, a SU block plate is used to block the stations under different pressures. Specify the mounting position by means of the manifold specification sheet. <lock indication label> Indication labels to confirm the blocking position are attached (Each for SU passage and SU/EXH passage blocking positions). When ordering a block plate incorporated with a manifold, a block indication label is attached to the manifold. EXH passage blocked EXH block base assembly Individual EXH spacer C (EXH port) C: ø One-touch fitting D side lock indication label label indicating the EXH passage blocking position is to be adhered. lock indication label U side SU passage blocked Description/Model Single Valve Option D side Individual EXH spacer VVQ000---C EXH blocking position: Specify places. Individual EXH spacer + EXH block base assembly (Not to be Valve ordered) SU/EXH passage blocked 7 Valve + EXH block base assembly (Not to be Valve ordered) U side 7

59 7 8 ase Mounted lug-in Unit -VQ000 EXH block base assembly F VVQ (C/C/C/M/N/N/N7) Manifold block assembly Electrical entry F0 F F F L0 L L Without lead wire For F kit ( to stations)/double wiring For F kit ( to stations)/double wiring For F kit ( to stations)/single wiring For, G, T, S kit ( to stations)/double wiring For, G, T, S kit ( to stations)/double wiring For, G, T, S kit ( to stations)/single wiring L0 kit L kit to 8 stations L kit Name plate [-N] VVQ000- N NC -N-Station ( to Max. stations) lanking plug (For One-touch fittings) KQ- It is inserted into an unused cylinder port and SU/EXH ports. urchase orders are available in units of 0 pieces. ort plug VVQ L The manifold block assembly is used between stations for which exhaust is desired to be divided when valve exhaust affects other stations due to the circuit configuration. The EXH passage on the D-side is blocked in the EXH block base assembly. It is also used in combination with an individual EXH spacer for individual exhaust. <lock indication label> Indication labels to confirm the blocking position are attached. (Each for EXH passage and SU/EXH passage blocking positions) When ordering a EXH block base incorporated with a manifold, a block indication label is attached to the manifold. ack pressure check valve assembly [-] VVQ000-8 It prevents cylinder malfunction caused by other valve exhaust entry. Insert it into (EXH) port on the manifold side of a valve which is affected. It is effective when a single-acting cylinder is used or an exhaust center type solenoid valve is used. When ordering it being mounted on all manifold stations, suffix - to the end of the manifold part number. Note) When a back pressure check valve is desired, and is to be installed only in certain manifold stations, clearly indicate the part number and specify the mounting station by means of the manifold specification sheet. It is a transparent resin plate for placing a label that indicates solenoid valve function, etc. Insert it into the groove on the side of the end plate and bend it as shown in the figure. When the blanking plate with connector is mounted, it automatically will be VVQ000-NC-n When ordering this option incorporated with a manifold, suffix -N to the end of the manifold part number. Specify the mounting station by means of the manifold specification sheet. When ordering this option incorporated with a manifold, specify the EXH block base assembly part number with in front of it beneath the manifold part number. N: Standard NC: For mounting blanking plate with connector The plug is used to block the cylinder port. When ordering this option incorporated with a manifold, indicate CM for the port size of the manifold part number, as well as, the mounting station and cylinder port mounting positions () and () by means of the manifold specification sheet. Gently screw an M screw in the port plug hole and pull it for removal. DIN rail mounting bracket [-D,-D0,-D ] VVQ000-7 This bracket is used for mounting the manifold on the DIN rail. When ordering this option incorporated with a manifold, suffix -D to the end of the manifold part number. EXH passage blocked Solid forming EXH passage blocked pcs. in set 9 lack screw Dimensions pplicable fitting size ød. 8 lock indication label Note) ( ): VVQ000-NC-n Model KQ- KQ-0 KQ-0 KQ-08 Hole SU/EXH passage blocked = 0. L D set of DIN rail mounting brackets for manifold includes brackets. DIN rail clamp screw Mounting screws included D side U side D side pplicable fitting size ød /8" /" /" /" EXH block base assembly U side (recautions). The back pressure check valve assembly is the parts with a check valve structure. However, since the valve has slight air leakage, take precautions for the exhaust air not to be restricted at the exhaust port.. When a back pressure check valve is mounted, the effective area of the valve will decrease by about 0%. n: Model KQ-0 KQ-0 KQ-07 KQ-09 L D Directional Control Valves Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control Flow Control ressure Switches/ ressure Sensors

60 -VQ000 -VQ000: Manifold Optional arts lanking plate assembly VVQ000- Symbol It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. Individual SU spacer C8 VVQ N9 When the same manifold is to be used for different pressures, individual SU spacers are used as SU ports for different pressures. (One station space is occupied.) lock both sides of the station, for which the supply pressure from the individual SU spacer is used, with SU block plates. (efer to the application example.) Specify the spacer mounting position and SU block plate position by means of the manifold specification sheet. The block plate is used in one or two places for one set. (Two SU block plates for blocking SU station are attached to the individual SU spacer.) s a standard, electric wiring is connected to the position of the manifold station where the individual SU spacer is mounted. If wiring is not required for stations equipped with spacers, enter X in the special wiring specifications column in the manifold specification sheet. SU block plate Individual SU spacer C8 (SU port) C8: ø8 One-touch fitting D side U side lock indication label label indicating the SU passage blocking position is to be adhered. D side SU block plate SU block plate Valve Individual Valve Valve SU spacer U side Individual EXH spacer C8 VVQ000---N9 When valve exhaust affects other stations due to the circuit configuration, this spacer is used for individual valve exhaust. (One station space is occupied.) lock both sides of the individual valve EXH station. (efer to the application example.) Specify the mounting position, as well as the EXH block base or EXH block plate position by means of the manifold specification sheet. The block plate is used in one or two places for one set. (Two EXH block plates for blocking EXH station are attached to the individual EXH spacer.) s a standard, electric wiring is connected to the position of the manifold station where the individual EXH spacer is mounted. If wiring is not required for stations equipped with spacers, enter X in the special wiring specifications column in the manifold specification sheet. EXH block plate Individual EXH spacer D side C8 (EXH port) C8: ø8 One-touch fitting U side lock indication label label indicating the EXH passage blocking position is to be adhered. D side EXH block plate EXH block plate Valve Individual Valve Valve EXH spacer U side SU block plate VVQ000- lock indication label When different pressures are supplied to a manifold, a SU block plate is used to block the stations under different pressures. Specify the mounting position by means of the manifold specification sheet. <lock indication label> Indication labels to confirm the blocking position are attached. (Each for SU passage and SU/EXH passage blocking positions) SU passage blocked D side U side SU/EXH passage blocked When ordering a block plate incorporated with a manifold, a block indication label is attached to the manifold. EXH block plate VVQ000-9 The EXH block plate is used between stations for which exhaust is desired to be divided when valve exhaust affects other stations configuration. It is also used in combination with an individual EXH spacer for individual exhaust. Specify the mounting position by means of the manifold specification sheet. pcs. in set D side U side lock indication label <lock indication label> Indication labels to confirm the blocking position are attached. (Each for EXH passage and SU/EXH passage blocking positions) EXH passage blocked 7 SU/EXH passage blocked When ordering a block plate incorporated with a manifold, a block indication label is attached to the manifold.

61 ase Mounted lug-in Unit -VQ000 ack pressure check valve assembly [-] VVQ000-8 It prevents cylinder malfunction caused by other valve exhaust entry. Insert it into (EXH) port on the manifold side of a valve which is affected. It is effective when a single-acting cylinder is used or an exhaust center type solenoid valve is used. When ordering assemblies incorporated with a manifold, add suffix - to the end of the manifold part number. Note) When a check valve for back pressure prevention is desired and is to be installed only in certain manifold stations, clearly indicate the part number and specify the mounting position by means of the manifold specification sheet. Name plate [-N] VVQ000-N-Station ( to Max. stations) It is a transparent resin plate for placing a label that indicates solenoid valve function, etc. Insert it into the groove on the side of the end plate and bend it as shown in the figure. When ordering this option incorporated with a manifold, suffix -N to the end of the manifold part number. lanking plug (For One-touch fittings) KQ- It is inserted into an unused cylinder port and SU/EXH ports. urchase orders are available in units of 0 pieces. DIN rail mounting bracket [-D,-D0,-D ] VVQ000-7 This bracket is used for mounting the manifold on the DIN rail. When ordering this option incorporated with a manifold, suffix -D to the end of the manifold part number. set of DIN rail mounting brackets for manifold includes brackets. pcs. in set pplicable fitting size ød 8 0 DIN rail clamp screw = Dimensions Model KQ-0 KQ-0 KQ-08 KQ-0 L D (recautions). The back pressure check valve assembly is assembly parts with a check valve structure. However, since the valve has slight air leakage, take precautions for the exhaust air not to be restricted at the exhaust port.. When a back pressure check valve is mounted, the effective area of the valve will decrease by about 0%. 8 0 n: pplicable fitting size ød /" /" /" /8" Model KQ-0 KQ-07 KQ-09 KQ- L D Flow Control Directional Control Valves ir reparation ressure Control Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders 7 ressure Switches/ ressure Sensors

62 -VQ000/000 Specific roduct recautions e sure to read this before handling. efer to page 8 for Safety Instructions and pages 77 to 8 for // ort Solenoid Valve recautions. Light/Surge Voltage Suppressor Caution The lighting positions are concentrated on one side for both single solenoid type and double solenoid type. In the double solenoid type, side and side energization are indicated by two colors which match the colors of the manual overrides. Manual override: Green Manual override: Orange (Drawing shows a VQ000 case.) DC circuit diagram Single solenoid COM (+) [SOL.] ositive common everse current prevention diode LED Coil Note) -side energization: light (Orange) illuminates. -side energization: light (Green) illuminates. Indicator light: Orange Indicator light : Orange : Green Single solenoid Double solenoid Double solenoid [SOL.] LED (Green) COM (+) LED [SOL.] (Orange) everse current prevention diode Coil Coil With wrong wiring prevention (stop diode) mechanism With a surge absorption (surge absorption diode) mechanism Manual Override Warning Without an electric signal for the solenoid valve the manual override is used for switching the main valve. ush type is standard. (Tool required) Locking type is semi-standard. (Tool required/manual) ush type (Tool required) ore ø. ore ø. ore ø. -VQ000 -VQ000 Locking type (Tool required) <Semi-standard> ore ø. -VQ000 -VQ000 Locking type (Manual) <Semi-standard> 0 mm mm ush down on the manual override with a small screwdriver, etc. until it stops. elease the screwdriver and the manual override will return. ush down on the manual override with a flat head screwdriver until it stops. Turn it clockwise by 90 to lock it. Turn it counterclockwise to release it. ush down on the manual override with a small flat head screwdriver or with your fingers until it stops. Turn it clockwise by 90 to lock it. Turn it counterclockwise to release it. -VQ000 -VQ000 Caution Do not apply excessive torque when turning the locking type manual override. (0. N m or less) 7

63 -VQ000/000 Specific roduct recautions e sure to read this before handling. efer to page 8 for Safety Instructions and pages 77 to 8 for // ort Solenoid Valve recautions. Warning Slide locking type (Manual) <Semi-standard> ore ø.7 OFF ON VQ000 ore ø OFF ON ore ø VQ000 Clamp bracket OFF Clamp bracket Orange OFF position ON Orange OFF position Clamp screw Green ON position How to Mount/emove Solenoid Valves Caution Manual Override Green ON position The manual override is locked by sliding it all the way to the pilot valve side (ON side) with a small flat head screwdriver or finger. Slide it to the fitting side (OFF side) to release it. In addition, it can also be used as a push type by using a screwdriver, etc., of ø.7 or less. (ø or less for VQ000). emoving. Loosen the clamp screw until it turns freely. (The screw is captive.). Lift the coil side of the valve body while pressing down slightly on the screw head and remove it from the clamp bracket. When the screw head cannot be pressed easily, gently press the area near the manual override of the valve. How to Mount/emove Solenoid Valves Caution Mounting. ress down on the clamp screw. Clamp bracket opens. Diagonally insert the hook on the valve end plate side into clamp.. ress the valve body downward. (When the screw is released, it will be locked by clamp bracket.). Tighten the clamp screw. (roper tightening torque: VQ000, 0. to 0. N m; VQ000, 0. to 0.7 N m.) Caution Dust on the sealing surface of the gasket or solenoid valve can cause air leakage. eplacement of Cylinder ort Fittings Caution The cylinder port fittings are a cassette for easy replacement. The fittings are blocked by a clip. Take out the clip with a flat head screwdriver, etc., then replace the fittings. For mounting, insert the fitting assembly until it strikes against the inside wall and then insert the clip to the specified position. pplicable tubing O.D. pplicable tubing ø. pplicable tubing ø pplicable tubing ø pplicable tubing ø8 M pplicable tubing ø/8" pplicable tubing ø/" pplicable tubing ø/" pplicable tubing ø/" Fitting assembly Clip -VQ000 -VQ000 Fitting assembly part no. -VQ000 -VQ000 VVQ000-0-C VVQ000-0-C VVQ000-0-C VVQ000-0-M VVQ000-0-N VVQ000-0-N VVQ000-0-N7 VVQ000--C VVQ000--C VVQ000--C8 VVQ000--N VVQ000--N7 VVQ000--N9 efer to Manifold Optional arts on pages 7 for other types of fittings. Caution. Use caution that O-rings must be free from scratches and dust. Otherwise, air leakage may result.. fter screwing in the fittings, mount the M fitting assembly on the manifold base. (Tightening torque: 0.8 to. N m). urchase orders are available in units of 0 pieces. Clip Fitting assembly 7 Directional Control Valves Fittings & Tubing Modular F.. ir Grippers otary ctuators ir Cylinders ir reparation ressure Control Flow Control ressure Switches/ ressure Sensors

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000

More information

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),

More information

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000 D-sub Connector J Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000//000 Number of connectors: pins MIL-C-08 Conforming to JIS-X-0 --6 For details

More information

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring Type4 SY000/000 ase Mounted Monifold Stacking Type/DIN ail Mounted Individual Wiring How to Order Manifold SSY 4 0 U C6 How to Order Valve Manifold ssembly Ordering example SY000 SY000 Valve stations 02

More information

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Series VQ Rubber Seal Space-saving profile Clean space saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Port Solenoid Valve Metal Seal Rubber Seal Series Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

How to Order Manifold. Kit type L8 B4 B6 B8 LM

How to Order Manifold. Kit type L8 B4 B6 B8 LM 0 Stations station VVQ Series VQ000 The maximum and minimum number of are varied depending on. (Refer to the table below.) Series VQ000 ase Mounted Plug-in Unit Manifold Plug-in unit 08 C Cylinder port

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Rubber Seal Series VQ Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

Base Mounted Plug-in/Plug Lead: Single Unit

Base Mounted Plug-in/Plug Lead: Single Unit ase mounted VQ ase Mounted lug-in/lug Lead: Single Unit Model Number of solenoids Model Single Metal seal VQ Rubber seal VQ ouble Metal seal VQ Rubber seal VQ Closed Metal seal VQ VQ center Rubber seal

More information

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications Series -SQ00 Port Solenoid Valve Plug-in Unit [Option] How to Order Manifold Electrical entry F kit D-sub connector kit P kit SSQ 08 FD Kit type Flat ribbon cable connector kit J kit Flat ribbon cable

More information

Plug Lead Unit: Flip Type

Plug Lead Unit: Flip Type Series ody orted lug Lead Unit: Flip Type For details about certified products conforming to international standards, visit us at www.smcworld.com. 0 Series Kit/Electrical entry/cable length F kit (D-sub

More information

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308 Cable ppendix Cable ppendix Multi-way cables The multi-pole connector cables used on SMC valves are common across several ranges. Cables are available in accordance with the MIL standard C-08 and also

More information

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve ubber Seal / ort Solenoid Valve Series 000 / 000 / 000 [Option] SJ SY SV SZ V S000 VQ VQ VQ VQC VQZ SQ VFS VF VQ Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating / ort Solenoid Valve ubber Seal Series SYJ000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Specifications JIS Symbol port port (manifold) position

More information

Series VQZ1000/2000/3000 Single Unit

Series VQZ1000/2000/3000 Single Unit +- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body

More information

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve CT.E- ase Mounted Type Series VQ Port Metal Seal/Rubber Seal Solenoid Valve dvanced manifold va the new age of factory au ase Mounted Type Space saving profile Clean space saving design with all pilot

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and

More information

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer Base Mounted Metal Seal/Rubber Seal VQ Built-in silencer, direct exhaust Space-saving profile All pilot valves are compactly mounted on one side. The space-saving design of mounting all fittings on one

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M. V3 Cover

More information

Series SY3000/5000 How to Order Manifold

Series SY3000/5000 How to Order Manifold Type N ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN Rail Mounted/Connector ox SY/ How to Order Manifold SSY SY SY Specifications Symbol Specifications With connector box (COM spec.) N With

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 0 PW COM Rubber Seal Port Solenoid Valve Series SZ000 Cassette Type Manifold The plug-in cassette system makes valve replacement easy. plug-in manifold has been created with a height of. mm (including

More information

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I ISO Standard Solenoid Valve Series VQ7-6/7-8 (Size ) (Size ) Conforms to ISO Standard /I.0- Ideal for driving cylinders up to Large flow capacity ø00 (VQ7-6, Size ) ø60 (VQ7-8, Size ) Nl/min VQ7-6: 668.

More information

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

More information

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A Type N SY/ ase ounted anifold Stacking Type/DIN Rail ounted Connector ox How to Order anifold SSY SY SY Specifications Symbol Specifications With connector box (CO spec.) N With connector box ( CO spec.)

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve CT.ES8 / ort Solenoid Valve Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M.7 to M2. 앬 Flow Characteristics Series Cover (stainless

More information

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal

More information

Example. U side. Stations SY5000

Example. U side. Stations SY5000 45 Type 5 ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN ail Mounted/Individual Wiring Series SY3000/5000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 3 45 05 U C6 Example

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

Terminal Block Box (Spring Type) SY3000/5000/7000 Series

Terminal Block Box (Spring Type) SY3000/5000/7000 Series INFORMATION 5 ort olenoid alve Terminal lock ox (pring Type) Y3000/5000/7000 eries Compact RoH Height 6.7 mm shorter (Approx. 9% reduction) Installation area of the terminal block box Reduced by approx.

More information

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot ubber seal ort ilot Solenoid Valve Series SYJ00 Specifications efer to www.smcworld.com for details of products compatible with overseas standards. Body ported Base mounted Fluid Operating pressure range

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit CT.EUS8 UK ower Consumption / ort Solenoid Valve With ower Saving Circuit Series SYJ000/000/7000 Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced

More information

3 Port Solenoid Valve

3 Port Solenoid Valve 3 ort Solenoid Valve Series VKF300 ubber Seal Direct Operated oppet Type Compact yet provides a large flow capacity Body width 8 mm vailable in vacuum applications ( 0. ka) Can be used in vacuum/release

More information

Fieldbus System (Output device for driving 5 port solenoid valves)

Fieldbus System (Output device for driving 5 port solenoid valves) Fieldbus System (Output device for driving port solenoid valves) New Compact 8mm (ctual size) Space-saving Installation IP67 RoHS EtherNet/IP added! For units with D-sub connector, and when connected to

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type20P 5 Port Solenoid Valve ody Ported Manifold ar Stock Type/Flat Ribbon Cable Series SY3000/5000/7000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 5 20P 05 Manifold series 3 SY3000

More information

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A) ort Solenoid Valve ubber Seal Series SY00 Low power consumption: 0.W (Standard, Without light) (Current draw: m at V DC) Large flow capacity style:0.7w (Current draw: m at V DC) Body width: 0mm 7.8 Nl/min

More information

2.26 S OLENOID VALVES S ERIES VQ1000

2.26 S OLENOID VALVES S ERIES VQ1000 2.26 S OLENOID VALVES 5 PORT M ETAL S EAL/RUBBER S EAL U LTRA H IGH S PEED S OLENOID VALVE High Speed Response from new Solenoid Design. Long Life: Over 200 Million Cycles can be with Patent Pilot Valve

More information

0.35 W (Without light)

0.35 W (Without light) Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:

More information

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position

More information

How to Order Manifold. Control unit Refer to pages to Kit/Electrical entry/cable length. kit (D-sub connector) U0 U1 U2

How to Order Manifold. Control unit Refer to pages to Kit/Electrical entry/cable length. kit (D-sub connector) U0 U1 U2 VQ000 ase Mounted Plug-in nit For details aout certified products conforming to international standards, visit us at www.smcworld.com. Type of connection VVQ VQ000 R port P port Port R Manifold Plug-in

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type1P Type2P 5 Port Solenoid Valve ase Mounted Manifold ar Stock Type/Flat Ribbon Cable Series /5000/000 How to Order Manifold Type 1P/Compact style SS5Y 5 1P 05 C8 Manifold series 3 5, port size Thread

More information

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles ort Solenoid Valve: ase Mounted Metal Seal/Rubber Seal Series Space and capacity saving ilot valve is gathered at one side. Space saving design which does not have any protrusions. Space saving Capacity

More information

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is. Port Solenoid Valve Series VQ 00 Unprecedented high speed, stable response, and extra-long service life. ON:.ms, OFF: ms, Dispension accuracy ±ms (With indicator light and surge voltage suppressor; supply

More information

Series SYJ300/500/700

Series SYJ300/500/700 ort Solenoid Valve ubber Seal Series SYJ00/00/00 Low power consumption: 0.W (Without light) (Current draw: 1m at 4V DC) Completely interchangeable ilot exhaust with the previous series VJ00/00/00 and VZ00/00.

More information

Applicable bore size. CC-Link. EtherNet/IP. Decentralized Serial Wiring. EtherCAT I/O. Serial unit: EX600 IP67 compliant. Serial unit: EX500

Applicable bore size. CC-Link. EtherNet/IP. Decentralized Serial Wiring. EtherCAT I/O. Serial unit: EX600 IP67 compliant. Serial unit: EX500 5 Port Solenoid Valve Series C000 Metal Seal Rubber Seal Compact and large flow Type (Series) Manifold pitch (mm) C000 5 6. 0.7.7 7. 0..0 to ø Note) Flow characteristics: position single, / 5/ (/ R/R)

More information

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection Rubber Seal Port Solenoid Valve Series SJ000/000 Cassette Type Manifold 0 mm 7. mm (SJ000) 0 mm (SJ000) Non plug-in type Individual wiring manifold SJ000 SJ000 Can be mounted together. Connecter connection

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

F Kit. D-sub. connector. D-sub. connector) Compatible network DeviceNet PROFIBUS DP. CC-Link. Compatible D-sub connector. Output

F Kit. D-sub. connector. D-sub. connector) Compatible network DeviceNet PROFIBUS DP. CC-Link. Compatible D-sub connector. Output Series VQC000 ase Mounted: Variations 5 Port Solenoid Valve Series VQC000 Sonic Conductance C[dm /(s bar)] Values: CYL EXH / 5/ Single/Double position (Closed center) pplicable bore size Compatible network

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle. Multistage Ejector 112/212 Series Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus

More information

Conforms to ISO Standard Size 18 mm, 26 mm Plug-in Type. 5 Port Solenoid Valve

Conforms to ISO Standard Size 18 mm, 26 mm Plug-in Type. 5 Port Solenoid Valve Conforms to IO 0- tandard ize mm, mm Plug-in Type Port olenoid Valve eries V -/V - R R [Option] eries V R- eries V R- Conforms to IO 0- tandard IO tandard: Interface conforming to mm size (V -) and mm

More information

Compact Vacuum Ejector

Compact Vacuum Ejector Compact acuum Ejector Series ZA Total length Total width 7.9 mm 9.9 mm Total height. mm Response time 0 ms Response time for up to 0 ka Nozzle diameter: ø0.7 iping: ø/ø. x 0 mm Able to install on the moving

More information

Series SYJ3000/5000/7000

Series SYJ3000/5000/7000 , ort Solenoid Valve ubber Seal Series SYJ000/000/7000 Low power consumption: 0.W(Without light) (Current draw: 1m at V DC) right color tone and state of the art design SY SYJ SX VK VZ VF VF V7 V Completely

More information

How to Order Manifold. Option Symbol

How to Order Manifold. Option Symbol Series Plug Lead nit For details about certified products conforming to international standards, visit us at www.smcworld.com. Series/Manifold 12 Stations 01 1 station Kit/Electrical entry/cable length

More information

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type. Series -S00 ompact Direct Operated Port Solenoid Valve ontrol Valves ase mounted ody ported lean Series lean Series V S R oil voltage 24 VD VD VD VD VD Power consumption Pressure specification Flow rate

More information

3 Port Air Operated Valve. SYJA300 Series. How to Order. Nil Without sub-plate. Type of actuation. Normally closed Normally open

3 Port Air Operated Valve. SYJA300 Series. How to Order. Nil Without sub-plate. Type of actuation. Normally closed Normally open 3 ort ir Operated Valve SYJ300 Series How to Order SYJ3 M3 Bracket Nil Without bracket F With bracket *The bracket is not mounted. *The bracket cannot be retrofitted later. SYJ3 Type of actuation Normally

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles Port Solenoid Valve: ase Mounted Metal Seal/Rubber Seal Series VQ Space and capacity saving Pilot valve is gathered at one side. Space saving design which does not have any protrusions. Space saving Capacity

More information

Space Saving Vacuum Ejector/Vacuum Pump System

Space Saving Vacuum Ejector/Vacuum Pump System Space Saving acuum Ejector/acuum ump System Series Current 21.6 mm mm Width mm [Option] Weight 9 g Single unit with vacuum pressure switch and suction filter ZK2 ZR Z Z ZM ZL -X267 ZU Ejector.2 ump System.118

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal Port Solenoid Valve Cassette Type Manifold Rubber Seal 7.mm (SJ000) SJ000 SJ000 Can be mounted together. 0mm (SJ000) Connector connection New New cable type manifold is added! New Additional options are

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

Series SV1000/2000/3000/4000

Series SV1000/2000/3000/4000 Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double

More information

Fieldbus System (Gateway Decentralized Type)

Fieldbus System (Gateway Decentralized Type) Fieldbus System (Gateway Decentralized Type) * * Except the SY, VQC and S0700 valves GW Unit which supports PROFINET added. New M connector type Input Unit added. Decentralized valve installation Valves

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

Series PCW. PC Wiring System

Series PCW. PC Wiring System CT.ES0-0 PC Wiring System Series PCW The PC wiring system is a revolutionary new system that simplifies wiring between a PLC and all types of connected equipment. revolutionary new wiring system... 4VDC

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

New Concept Connector Type Manifold

New Concept Connector Type Manifold New Concept Connector Type Manifold Series /000/3000/000 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration.

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Vacuum Release Valve with Restrictor Series SJ3A6 SJ Plug-in Type Connector Connection P.86 D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Non Plug-in Type Individual

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

Non-Contact Sensor for Workpiece Placement Verification

Non-Contact Sensor for Workpiece Placement Verification ir Catch Sensor Series 2 Non-Contact Sensor for Workpiece Placement Verification Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact

More information

5 Port Solenoid Valve Plug Lead Type

5 Port Solenoid Valve Plug Lead Type 5 Port Solenoid alve Plug Lead Type Series Body Ported Flow rate characteristics For single/double solenoid C [dm 3 /(s bar)]: 0.6 Single Unit alve width: 7.4 mm Possible to drive cylinders: Up to ø32

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry

More information

CMF2 Series Applicable cylinder bore size: Max. ø160

CMF2 Series Applicable cylinder bore size: Max. ø160 4G/ M4G/ Individual wiring manifold ISO size 2 DIN terminal ox type 5 port pilot operated valve ISO conformed valve 2 Series pplicale cylinder ore size: Max. ø160 MN4G/ Common specifications 4G/ W4G/2

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3

More information

4/5 Port Air Operated Valve. SYJA3000 Series. How to Order. (Manifold use only) Type of actuation. 2 position single. 3 position closed center

4/5 Port Air Operated Valve. SYJA3000 Series. How to Order. (Manifold use only) Type of actuation. 2 position single. 3 position closed center 4/ ort ir Operated Valve SYJ000 Series How to Order ody ported SYJ M racket Nil Without bracket F With bracket *Refer to page 47 for the details of the brackets. ase mounted (4 port) SYJ 2 0 (Manifold

More information

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Body Ported Base Mounted Series S000 S000 S000 S000 S000 S4000 S5000 Sonic conductance C [dm /s bar)] 4/ 5/(A/B R/R) Single Double.8.4

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

Vacuum System Peripherals

Vacuum System Peripherals Vacuum System Peripherals Vacuum Regulator/Electronic Vacuum Regulator Vacuum regulator: IRV0/0 Electronic vacuum regulator: ITV009/ITV09 Directional Control Valve Selection guide of directional control

More information

3 Port Air Operated Valve

3 Port Air Operated Valve Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation

More information

CAT.E152-5 Port Solenoid Valve/Body Ported Cassette Type Manifold. Series SZ3000

CAT.E152-5 Port Solenoid Valve/Body Ported Cassette Type Manifold. Series SZ3000 CAT.E- Port Solenoid Valve/Body Ported Cassette Type Manifold Series SZ000 The plug-in cassette system makes valve replacement easy. A plug-in manifold has been realized having a manifold height of.mm

More information

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold Port Solenoid Valve VV00 Series Highly Integrated Unit Manifold po ted - pera irect-o d station es on rt valv ally ividu Ind wired n be ve ca val d. adde ector Con-inn connection) lug (For p ø connection

More information