4 Port Solenoid Valve
|
|
- Dominick Wood
- 6 years ago
- Views:
Transcription
1 Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean and dry air.) vailable in vacuum applications (Up to 101. kpa) an be used in vacuum/release circuits When used as a port valve, conversion from N.O. to N.. and vice versa is possible by plugging either port () or (). ompact and lightweight ( g) with large flow capacity ody width of 10 mm, : 0. dm /(s bar) W : 0.7 dm /(s bar). W (U type: Large flow) [Option] lean room specifications available as special. Since the main valve has no sliding seals, non-oil treatment specification at the fluid contacting section is available (Made-to-Order part no. X16). The external non-leak specification is also available (Series 10-). VV061 VV100 V100 S070 VQD VQD-V VKF VK VT VS VS ody ported ylinder Speed hart opper-free specifications The fluid contacting section is copper-free and the standard style can be used as it is. ase Mounted Series VQD111U verage speed (mm/s) Use as a guide for selection. Please confirm the actual conditions with SM Sizing Program. ore size Series J Series M Pressure 0. MPa Pressure: 0. MPa Load factor 0% Load ratio: 0% Stroke 60 mm Stroke: 00 mm ø6 ø10 ø16 ø0 ø ø ø0 Perpendicular, upward actuation Horizontal actuation It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. Load factor: ((Load weight x 9.8)/Theoretical force) x 100% onditions Series J Series M Tube bore x Length TU0 x 1m VQD111U Speed controller S101F-M-0 S01F-0-0 Silencer N10-M 199
2 Port Solenoid Valve Direct Operated Poppet Type How to Order Valves [Option] L plug connector M plug connector VQ D1 1 1 L Type of actuation Single type () () Latching type 1 (R) (P) () () 1 (R) (P) ody type ody ported (Single unit) ody ported (Manifold) Note) Latching type: type only. Valve option V U W Standard Vacuum For large flow (1) For large flow, vacuum (1) Note 1) Latching type: U and W only Note ) Latching type (-OM): NU and NW Rated voltage L plug connector ody ported M plug connector ody ported 6 VD 1 VD Note) Latching type: VD only Standard Specifications Valve specifications Electricity specifications M M Electrical entry L: Plug lead type L plug connector, With lead wire Type Item Valve construction Fluid Maximum operating pressure Minimum operating pressure/vacuum Response time (1) mbient and fluid temperature Lubrication Manual override Impact/Vibration resistance () Mounting position Enclosure Weight oil rated voltage D llowable voltage fluctuation oil insulation type Power consumption D Electrical entry Standard single type Large-flow single type port direct operated poppet valve ir/inert gas 0.7 MPa 0 MPa / 101. kpa Large-flow latching type ON: ms±1, OFF: ms±1 10ms or less 10 to 0 () Not required Non-locking push type Locking type 10/0 m/s Unrestricted Dust tight g V, 1 V 7 g D ±10% of rated voltage lass or equivalent W. W (Energy saving type) (Inrush:. W, Holding: 1.0 W) () W L plug connector, M plug connector (With indicator light and surge voltage suppressor) Note 1) ased on dynamic performance test, JIS (oil temperature: 0, pressure: 0. MPa, at rated voltage, with light and surge suppressor, value at operation excluding restart period) The period immediately after a restart may be delayed for about 1 msec depending on operating conditions. Note ) Operating the valve at low temperatures may cause condensate to form, therefore dry air must be used. Note ) Impact resistance: Made to Order X16 Fluid-contact part: Oil-free Port size ody ported LO: Plug lead type L plug connector, Without connector M: Plug lead type M plug connector, With lead wire With light/ surge voltage suppressor MO: Plug lead type M plug connector, Without connector E-compliant E-compliant M thread Without sub-plate (Manifold) M thread No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Note ) For the start-up time, refer to the energy saving type s electrical power waveform on page 199 Wiring Specifications. Q Note) When you expect to energize the unit for extended periods of time, refer to page for details.
3 Port Solenoid Valve Direct Operated Poppet Type Flow haracteristics ody ported (With sub-plate) onstruction Symbol () () 1 (R) (P) Valve model L VQD111- M-M U L VQD111 W- M-M L VQD111- M-M 1 U L VQD1 1 W- M-M Port size M x 0.8 q u e!0 t r y Flow characteristics 1 / (P /) / / (/ E/E) [dm b v /(s bar)] [dm /(s bar)] b v i o w omponent Parts (Single Type) No Description Solenoid coil assembly Sub-plate ody Spool valve Poppet Guide ring Return spring Manual override Gasket Round head combination screw Note) ody cannot be disassembled. Material luminum ZD luminum HNR Resin Stainless steel luminum HNR Steel Note VQD1000-S-M ( only) VQD H XT6-7-1 (M1.7 x 18) VV061 VV100 V100 S070 VQD VQD-V VKF VK VT VS VS (R) () 1(P) () 1(P) Valve Single Unit Option Piping plate assembly VQD Manifold type (VQD111) can be changed to single unit type (VQD111) by mounting plate assembly. Note) Plate should be mounted with manifold mounting screws (M1.7 x 0). Proper tightening torque of thread: 0.18 to 0. N m 191
4 Dimensions/ody Ported L plug connector: VQD111 - L-M M plug connector: VQD111 - M-M Lead wire length 00 mm x M x 0.8 (), () port Indicator light Direct manual override (11) x ø. mounting hole L plug connector (L) 9 0. M plug connector (M) x M x 0.8 1(P), (R) port (R) 1 (P) 7. (1) 19
5 SM Port Solenoid Valve Direct Operated Poppet Type Dimensions/ase Mounted L plug connector: VQD111 - L-M M plug connector: VQD111 - M-M VV061 () () VV100 V100 S070 VQD Lead wire length 00 mm Indicator light 7 Direct manual override VQD-V VKF 9 (R).8 0. x mounting hole VK VT VS VS 1(P) 1 1(P) x M x (P), (), (), (R) port L plug connector (L) M plug connector (M) 19
6 SM Dimensions/ase Mounted L plug connector: VQD11 - L-M M plug connector: VQD11 - M-M 9 R 11 Lead wire: White Lead wire: Red Lead wire: lack In the case of +OM Direct manual override Indicator light Lead wire length 00 mm () P (8) PUSHU/TURN x mounting hole x M x (P), (), (), (R) port 1 The dashed line indicates L plug connector. 19
7 Port Solenoid Valve Direct Operated Poppet Type How to Order Manifold [Option] How to Order Valves [Option] Plug lead unit manifold VVQD1 Manifold ody ported Valve station 0 stations 0 0 stations (Max.) Port size(ylinder port) ody ported M thread M M thread One-touch fitting for ø 1(P), (R) port: Rc 1/8 How to Order Manifold ssembly E-compliant Q Specify the part numbers for valves and options together beneath the manifold base part number. <Example> Plug lead unit manifold VVQD1-0M 1 set Manifold base part no. VVQD set lanking plate part no. (1st station) VQD111-L sets Valve part no. ( to th station) E-compliant VQD1 1 1 Type of actuation 1 Single type Latching type ody type ody ported Note) Latching type: ase-mounted type only. Valve option Standard (W) V Vacuum ( W) Note) U For large flow (. W) Note) W For large flow, vacuum (. W) Note 1) Latching type: U and W only Note ) Latching type (-OM): NU and NW Rated voltage VD 6 1 VD Note) Latching type: VD only L: Plug lead type L plug connector, With lead wire L Electrical entry M VV061 VV100 V100 S070 VQD VQD-V VKF VK VT VS VS Prefix the asterisk to the part nos. of the solenoid valve, etc. Enter in order starting from the first station on the D side. VQD D side U side Stations 1 R 1P VQD111-L VVQD1-0M LO: Plug lead type L plug connector, Without connector M: Plug lead type M plug connector, With lead wire MO: Plug lead type M plug connector, Without connector M Port size (ody ported only) ody ported M thread E-compliant Q E-compliant 19
8 Manifold Options lanking plate assembly/ody ported VVQD lanking plate assembly includes screws and gasket lanking plate assembly/ VVQD lanking plate assembly includes screws and gasket Individual SUP spacer/ VVQD1000-P-M- Mount the individual SUP spacer on the manifold base, and thus making it possible to have supply port individually for each valve Individual SUP spacer with screw ( pcs.) and gasket M x 0.8 Supply port Individual EXH spacer/ VVQD1000-R-M- Mount the individual EXH spacer on the manifold base, and thus making it possible to have exhaust port individually for each valve. (ommon EXH type) 9 9. Individual EXH spacer with screw ( pcs.) and gasket M x 0.8 Exhaust port 196
9 Port Solenoid Valve Direct Operated Poppet Type Dimensions/ody Ported Plug lead unit manifold(vvqd1- ) x Rc 1/8 1(P), (R) port Lead wire length 00 mm Indicator light VV061 VV100 V100 7 x ø. (Mounting hole) S070 8 M plug connector (M) D side Stations 1 n U side Direct manual override (Non-locking) R R 0.6. VQD VQD-V P P=11 10 L L1 1 P. n x M (), () port M: M thread VKF VK VT VS VS L plug connector (L) Dimensions n: Stations L n L L
10 Dimensions/ase Mounted Plug lead manifold unit (VVQD1- ) Lead wire length 00 mm (P,R port) For latching Indicator light (9.7/latching type) (R) (R) x ø. (Mounting hole) M plug connector (M) P = n U side Direct manual override (Non-locking) (P) 1(P) : ø One-touch fitting L L1 D side Stations n x, M (), () port : One-touch fitting for ø M: M thread () () () () (6) P = L plug connector (L) Dimensions L n L1 L n: Stations
11 Specific Product Precautions 1 e sure to read before handling. Refer to front matter for Safety Instructions and pages to 8 for // Port Solenoid Valve Precautions. Warning onnected actuator is started by manual operation. Use the manual override after confirming that there is no danger. Single type: Non-locking push type (Tool required) ø Manual Override Operation In order to turn it ON, push down the manual override button in the direction the arrow ( ) indicates until it stops (approx. 0. mm), and release it to turn it OFF. Latching type: Locking type (Tool required) Manual override PUSHU/TURN Manual override-free position ontinuous Energization Warning oil temperature may get high due to ambient temperature or energizing duration. Do not touch the valve by hand directly. When there is such a dangerous case to be touched by hands directly, install a protective cover. When you expect to energize the single type for extended periods of time, refer to page for details. The latching type should not be energized over 0 seconds. e sure to wait more than you energize the unit (both and should be turned off.) before you move on to the next operation. w While pushing down the manual override until it stops, turn it by 90 and stop the arrow at or. The direction can be changed as desired. (: Flow path: P, : Flow path: P ) The manual override is in the locked state when it is released. The locking will be released and the manual override will return, when it is returned to the free position. Note) e sure to release the locking before starting the normal operation. Mounting of Valves aution fter confirming the gasket is correctly placed under the valve, securely tighten the bolts with the proper torque shown in the table below. Proper tightening torque (N m) 0.18 to 0. q Mounting of Valves aution When piping and mounting valves, clamp the body part in place to avoid applying force to the coil. If you apply force over 10 N to coil, connection pins deform, which may cause malfunction. (Latching: 0 N or more) oil Pin Wiring Specifications aution Single type (Standard: W) Lead wire Red (+, ) ody SOL. LED lack (,+) Note) oil surge voltage generated when OFF is about 60 V. Please consult with SM when you need to reduce the surge voltage. Single type (Large flow:. W) Lead wire Red (+) lack ( ) Varistor Energy saring I. W type (Energy saving type) reduces current consumption at holding which reduces the overall power consumption using the circuit shown in the left figure. Refer to the energy saving type's electrical power waveform below. <Energy saving type s electrical power waveform> (Rated voltage: VD) pplied voltage V 0V SOL..W 1.0W 0W Fitting 1 to ms Latching solenoid type Positive common Lead wire ( ) Set lack ( ) -ON (+) OM SOL. Red (+) OM. ( ) Reset LED White ( ) -ON Negative common How to order connector assembly Lead wire D positive common Red (+) -ON Single lack ( ) OM. XT Latching XT White (+) -ON D negative common Latching XT661-1N- onnector and socket ( pcs.) only XT661-1 Simultaneous energization protection circuit Varistor Diode Energy saving type Simultaneous energization protection circuit Simultaneous energization protection circuit Lead wire length 00 mm mm mm mm mm SOL. SOL. Plug connector lead wire length Lead wire length of plug connector valve with lead wire is 00 mm. When ordering a valve with a lead wire of 600 mm or longer, be sure to indicate the model number of the valve without connector and connector assembly. 199 VV061 VV100 V100 S070 VQD VQD-V VKF VK VT VS VS
12 Specific Product Precautions e sure to read before handling. Refer to front matter for Safety Instructions and pages to 8 for // Port Solenoid Valve Precautions. aution Latching Type Latching The latching is equipped with a self-holding mechanism, which permits a movable iron core in the solenoid to hold the set (-ON) and reset (-ON) positions during momentary energization (0 ms or longer). Therefore, there is no need to energize continuously. < Special autions for Latching> 1. Use in a circuit that does not have simultaneous energization of -ON and -ON signals.. The minimum energization time required for self-holding is 0 ms.. lthough there is no problem for normal operations and environments, please consult SM when operating in an environment with vibration (10G or more) or strong magnetic fields.. When there is the magnetic body at the valve side, it may cause malfunction. llow a space over 10 mm between the valve and magnetic body.. Even though this valve is held on to -ON position (passage: P ), it may switch to the set position during transportation or due to impact when mounting valves, etc. Therefore, check the initial position by means of power supply or manual override prior to use. -ON (Set) -ON (Reset) Energization Passage Light color ( ) lack ( ) White Note) For positive common (+) Red (+) Red P ( R) P ( R) Orange Green How to Use the Valve for Vacuum pplications (When used as a port valve) aution pplication example of VQD11 1W V (Symbols used are typical examples.) Vacuum valve (R) 1(P) Vacuum pad How to alculate the Flow Rate Vacuum releasing air tmospheric pressure or micro pressure Use a VQD1 1 1 v valve for vacuum applications. w onnect the vacuum source to the (R) port. ir pressure cannot be applied to the (R) port. When used as a port valve, conversion from N.O. to N.. and vice versa is possible by plugging either port () or (). annot be used as port valve. For obtaining the flow rate, refer to front matters to. () () How to Use Plug onnector aution ttaching and detaching connectors To attach a connector, hold the lever and connector unit between your fingers and insert straight onto the pins of the solenoid valve so that the lever s pawl is pushed into the groove and locks. To detach a connector, remove the pawl from the groove by pushing the lever downward with your thumb, and pull the connector straight out. Note) Gently pull the lead wire, otherwise it may cause contact failure or disconnection. over Groove Lever Pin onnector Lever onnector 1960
4 Port Solenoid Valve
Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean
More information13 msec (at 500 mm )/18.5 msec (at 1000 mm )
Vacuum / Release Unit Series VQD1000-V Rubber Seal Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area [Option] Smooth detachment of a work piece without
More informationBody width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.
High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure of 0.5MPa, subject to clean, dry air) 4 Port Direct
More informationVacuum / Release Unit
Rubber Seal Vacuum / Release Unit Series VQD1000-V Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area Smooth detachment of a work piece without over-blow
More informationSeries VQ Port Solenoid Valve
Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors
More information3 Port Solenoid Valve
Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly
More informationVacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm
4 Port Direct Operated Poppet Solenoid Valve Series D1000 High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure
More informationHow to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.
Series -S00 ompact Direct Operated Port Solenoid Valve ontrol Valves ase mounted ody ported lean Series lean Series V S R oil voltage 24 VD VD VD VD VD Power consumption Pressure specification Flow rate
More information3 Port Solenoid Valve
Rubber Seal Port Solenoid Valve Series Manifold Single Unit ase Mounted Manifold VV01 V100 ar base P.18 ody Ported P.10 ase Mounted P.10 VQD VKF VK VT VS Separable base ody Ported Manifold P.1 Stacking
More informationSpecifications. Fluid Ambient and fluid temperature ( C)
Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication
More informationSeries VKF300 VV061 V100 S070 VQD VKF VK VT VS
Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing
More information3 Port Solenoid Valve
Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series
More information1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions
Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]
More informationManual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry
Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal
More information3 Port Solenoid Valve Direct Operated Poppet Type
3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage
More information3 Port Solenoid Valve
3 ort Solenoid Valve Series VKF300 ubber Seal Direct Operated oppet Type Compact yet provides a large flow capacity Body width 8 mm vailable in vacuum applications ( 0. ka) Can be used in vacuum/release
More information3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option
3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity
More information3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.
3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body
More information10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry
Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body
More informationSeries VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non
Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non
More informationExhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)
5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust
More information5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal
Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body
More informationHow to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications
For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector
More information3 Port Air Operated Valve
Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation
More informationSeries VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4
Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double
More information5 Port Solenoid Valve Direct Operated Poppet Type. Specifications
Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W
More information3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option
Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable
More informationSeries VP3145/3165/3185
Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to
More information5 Port Solenoid Valve Direct Operated Poppet Type. Specifications
Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W
More informationFluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single
Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position
More informationPilot Operated 2 Port Solenoid Valve for Dry Air
Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0
More information5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range
For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR2 JIS Symbol type
More information5 Port Solenoid Valve
Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size
More information3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.
Port Solenoid Valve Series VQ 00 Unprecedented high speed, stable response, and extra-long service life. ON:.ms, OFF: ms, Dispension accuracy ±ms (With indicator light and surge voltage suppressor; supply
More information5 Port Solenoid Valve
ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and
More information5 Port Solenoid Valve
Metal seal Port Solenoid Valve Series VQ Rubber Seal Space-saving profile Clean space saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3
More information1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold
Port Solenoid Valve VV00 Series Highly Integrated Unit Manifold po ted - pera irect-o d station es on rt valv ally ividu Ind wired n be ve ca val d. adde ector Con-inn connection) lug (For p ø connection
More informationCoolant Valve. VNC Series. Cylinder actuation by pilot air
oolant VN Series ir Operated/xternal Pilot Solenoid [Option] ylinder actuation by pilot air Wide selection of port and variations Threaded type (6 to ) lange type (3 to 80) Low water hammer or details,
More information5 Port Solenoid Valve
ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high
More information3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)
ort Solenoid Valve ubber Seal Series SY00 Low power consumption: 0.W (Standard, Without light) (Current draw: m at V DC) Large flow capacity style:0.7w (Current draw: m at V DC) Body width: 0mm 7.8 Nl/min
More informationD-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector
Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position
More information5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted
Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted
More informationFlow characteristics Max. (1) b Standard Specifications. P Manual override.
Port Direct Operated Solenoid Valve Series 0 Metal Seal Model Number of positions (Single) (Double) ( position) JIS Symbol Model Port size Rc (Nominal size) 0-0 8 ( A) 0- ( 8A) 0-0 8 (0A) 0-0 8 ( A) 0-
More information3 Port 3 Position Valve
Port Position Valve Pilot Solenoid ir Operated ohs Intermediate stopping of cylinders * up to ø15 is possible. Pilot solenoid Manifold ir operated * For VEX 4, 00 mm/s, horizontal movement Power consumption:
More informationSeries SV1000/2000/3000/4000
Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model 2 position 3 position
More information5 Port Solenoid Valve
5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry
More informationSeries VQZ1000/2000/3000 Single Unit
+- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body
More information2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating
/ ort Solenoid Valve ubber Seal Series SYJ000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Specifications JIS Symbol port port (manifold) position
More information3 Port Solenoid Valve
ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M. V3 Cover
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position
More informationRubber Seal VP300/500/700
Port Pilot Operated Poppet Rubber Seal 00/500/700 High flow capacity Cv1.0 (00), Cv. (500), Cv.0 (700) Low power consumption: 1.8W(DC) Possible to use as either selector valve or divider valve Changeable
More informationSoft Start-up Valve. AV2000/3000/4000/5000 Series
Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off
More informationSeries VP3145/3165/3185
Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes
More information5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles
ort Solenoid Valve: ase Mounted Metal Seal/Rubber Seal Series Space and capacity saving ilot valve is gathered at one side. Space saving design which does not have any protrusions. Space saving Capacity
More information4/5 Port Air Operated Valve. SYJA3000 Series. How to Order. (Manifold use only) Type of actuation. 2 position single. 3 position closed center
4/ ort ir Operated Valve SYJ000 Series How to Order ody ported SYJ M racket Nil Without bracket F With bracket *Refer to page 47 for the details of the brackets. ase mounted (4 port) SYJ 2 0 (Manifold
More informationISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I
ISO Standard Solenoid Valve Series VQ7-6/7-8 (Size ) (Size ) Conforms to ISO Standard /I.0- Ideal for driving cylinders up to Large flow capacity ø00 (VQ7-6, Size ) ø60 (VQ7-8, Size ) Nl/min VQ7-6: 668.
More informationPower Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.
Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control
More informationCompact / Lightweight 2 Port Solenoid Valve
ompact / Lightweight 2 Port Solenoid Valve /-XF For ir/water ompact / Lightweight resin body (PPS) Weight: 20 g (-XF) RoHS IP65 mm Power consumption 3 W (Standard) 0.5 W (With power-saving circuit) 48
More information5 Port Solenoid Valve
ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series
More information5 Port Solenoid Valve
Metal seal Port Solenoid Valve Rubber Seal Series VQ Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less
More informationHow to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa
oolant Valve Series S External pilot solenoid S ir operated S How to Order 0 0 Y 0 0 T Z q w e r t y u i o!0!!!!! q Series S00 S00 S00 w Valve type ormally closed ormally open e Seal material R FKM r Pressure
More informationHow to Order Manifold. Kit type L8 B4 B6 B8 LM
0 Stations station VVQ Series VQ000 The maximum and minimum number of are varied depending on. (Refer to the table below.) Series VQ000 ase Mounted Plug-in Unit Manifold Plug-in unit 08 C Cylinder port
More informationBase Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer
Base Mounted Metal Seal/Rubber Seal VQ Built-in silencer, direct exhaust Space-saving profile All pilot valves are compactly mounted on one side. The space-saving design of mounting all fittings on one
More informationSeries SYJ300/500/700
ort Solenoid Valve ubber Seal Series SYJ00/00/00 Low power consumption: 0.W (Without light) (Current draw: 1m at 4V DC) Completely interchangeable ilot exhaust with the previous series VJ00/00/00 and VZ00/00.
More informationPower Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.
Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control
More information3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot
3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in
More informationRubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot
ubber seal ort ilot Solenoid Valve Series SYJ00 Specifications efer to www.smcworld.com for details of products compatible with overseas standards. Body ported Base mounted Fluid Operating pressure range
More information5 Port Solenoid Valve Plug Lead Type
5 Port Solenoid alve Plug Lead Type Series Body Ported Flow rate characteristics For single/double solenoid C [dm 3 /(s bar)]: 0.6 Single Unit alve width: 7.4 mm Possible to drive cylinders: Up to ø32
More information4/5 Port Solenoid Valve
CT.ES8 / ort Solenoid Valve Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M.7 to M2. 앬 Flow Characteristics Series Cover (stainless
More information4/5 Port Solenoid Valve
ubber Seal / ort Solenoid Valve Series 000 / 000 / 000 [Option] SJ SY SV SZ V S000 VQ VQ VQ VQC VQZ SQ VFS VF VQ Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread
More information5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure
For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Series 000 Compact and lightweight: 3 mm width Compact yet provides
More information(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC
5 Port Pilot Operated Solenoid Valve Metal Seal Series VZS Series Variations Plug-in Type Base Mounted Type (With sub-plate) Non Plug-in Type Base Mounted Type (With sub-plate) Series Sonic conductance
More informationVQ1000. How to Order Manifold. Kit type
- - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold
More informationPilot Operated 2 Port Solenoid Valve for Dry Air
Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible
More informationATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry
Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 044 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000 racket
More informationGrommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC
5 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Body Ported Base Mounted Series S000 S000 S000 S000 S000 S4000 S5000 Sonic conductance C [dm /s bar)] 4/ 5/(A/B R/R) Single Double.8.4
More information5 Port Solenoid Valve
Port Solenoid Valve Metal Seal Rubber Seal Series Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less
More informationATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry
TEX Compliant Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 44 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000
More informationHigh Pressure Coolant Valve
High Pressure Coolant Valve Series.5 MPa, 7.0 MPa Corresponding to high speed grinding and long drilling processes Coolant valve for high pressure coolant liquid (up to.5 MPa or 7.0 MPa) that is ideal
More information5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC)
Port Solenoid Valve/Direct Poppet Rubber seal Series VK3000 Nl/min 147 Compact/Width 18 X Length 8 (mm) Low power consumption 4W DC (Standard) 2W DC (Energy saver) Standard copper free specification All
More informationI N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications
I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000
More information0.35 W (Without light)
Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:
More informationCompact Vacuum Ejector
Compact acuum Ejector Series ZA Total length Total width 7.9 mm 9.9 mm Total height. mm Response time 0 ms Response time for up to 0 ka Nozzle diameter: ø0.7 iping: ø/ø. x 0 mm Able to install on the moving
More informationSeries SY3000/5000/7000
Type20P 5 Port Solenoid Valve ody Ported Manifold ar Stock Type/Flat Ribbon Cable Series SY3000/5000/7000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 5 20P 05 Manifold series 3 SY3000
More informationSeries SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510
Vacuum Release Valve with Restrictor Series SJ3A6 SJ Plug-in Type Connector Connection P.86 D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Non Plug-in Type Individual
More informationExclusively for air pressure system and air-hydro circuit control
Process Valve Series Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external
More information5 Port Air Operated Valve
Port ir Operated Valve Series VF000/000/000 RoHS 22- Series VF000/000/000 Model Selection by Operating Conditions q ir Operated Valve: Single Unit Series Sonic conductance C[dm /(s bar)] Type of actuation
More informationPower Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit
CT.EUS8 UK ower Consumption / ort Solenoid Valve With ower Saving Circuit Series SYJ000/000/7000 Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced
More information2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control
Process Valve Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external pilot
More informationVacuum System Peripherals
Vacuum System Peripherals Vacuum Regulator/Electronic Vacuum Regulator Vacuum regulator: IRV0/0 Electronic vacuum regulator: ITV009/ITV09 Directional Control Valve Selection guide of directional control
More informationNon-Contact Sensor for Workpiece Placement Verification
ir Catch Sensor Series 2 Non-Contact Sensor for Workpiece Placement Verification Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact
More information3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum
3 Port Direct Operated Poppet Rubber Seal Series 307 Large Flow Capacity, yet Compact Size. Dimensions (W X H X D) 30 X 54.5 X 33 307 Nl/min 206.02 or more, 1/4 Low Power Consumption /VO307 4.8W DC/Standard
More informationOption. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications
Series -SQ00 Port Solenoid Valve Plug-in Unit [Option] How to Order Manifold Electrical entry F kit D-sub connector kit P kit SSQ 08 FD Kit type Flat ribbon cable connector kit J kit Flat ribbon cable
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 MPa Pilot Operated /3 Port Solenoid Valve & Check Valve VCH Series VCH4/4: Port VCH40: 3 Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve [Option] VCH40 Series Stable responsiveness Response
More information