5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)
|
|
- Wilfrid Johnson
- 6 years ago
- Views:
Transcription
1 For details about certified products conforming to international standards, visit us at 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position Type of actuation Single Double Closed center Exhaust center Pressure center Plug-in VFS310 VFS30 VFS330 VFS340 VFS350 Model Non plug-in VFS3130 VFS330 VFS3330 VFS3430 VFS3530 Compact yet provides a large flow capacity 3/8: C: 6.8 dm 3 /(s bar) Low power consumption: 1.8 W DC JIS Symbol position 3 position Single Closed center Port size Rc C [dm 3 /(s bar)] Standard Specifications Option Specifications Manifold Flow characteristics 1 4/ (P A/B) 4/ 5/3 (A/B R1/R) b C [dm 3 /(s bar)] or less 15 or less Note 1) Based on JIS B 8375 (once per 30 days) for the minimum operating frequency. Note 3) In the case of grommet type. Note ) Based on JIS B (The value at supply pressure 0.5 MPa.) Note 4) Factors of Note1) and Note ) are achieved in controlled clean air. Double VFS330- E-03 VFS30- T-03 Exhaust center Pressure center VFS310- E-03-F VFS310- G-03 Valve specifications Electricity specifications Cv Fluid Maximum operating pressure Minimun operating pressure Proof pressure Ambient and fluid temperature Lubrication Pilot valve manual override Shock/Vibration resistance Enclosure Allowable voltage fluctuation Coil insulation type Apparent power Inrush (Power consumption) AC Holding Power consumption Electrical entry b Cv Air/Inert gas 1.0 MPa 0.1 MPa 1.5 MPa 10 to 60 C (1) Non-lube () Non-locking push type (Flush) 150/50 m/s (3) Dustproof (Degrees of protection 0) (4) 100, 00 VAC, 50/60 Hz; 4 VDC 15 to +10% of rated voltage Class B or equivalent (130 C) (5) 5.6 VA/50 Hz, 5.0 VA/60 Hz 3.4 VA (.1 W)/50 Hz,.3 VA (1.5 W)/60 Hz 1.8 W (.04 W: With light/surge voltage suppressor) Grommet, Grommet terminal, Conduit terminal, DIN terminal Note 1) Use dry air at low temperatures. Note ) Use turbine oil Class 1 (ISO VG3), if lubricated. Note 3) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Note 4) Based on JIS C 090. Note 5) Based on JIS C Pilot type External pilot (1) Pilot valve manual override Non-locking push type (Extended), Locking type (Tool reguired) 110 to 10, 0, 40 VAC (50/60 Hz) 1, 100 VDC Option With light/surge voltage suppressor () Foot bracket (With screw) Part no.: VFS3000-5A, VFS310 (single) only Note 1) Operating pressure: 0 to 1.0 MPa Pilot pressure: 0.1 to 1.0 MPa Body type VFS3 0 VFS3 30 Applicable manifold base Stacking manifold Max. operating cycle (cpm) Response time (ms) Note ) Grommet type is available only w/ surge voltage suppressor (which is directly connected with lead wire), not w/ indicator light. Pilot EXH Individual EXH (Valve side) Common EXH (Manifold base side) (1) () (3) Weight (kg) VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN 3-8-5
2 Series VFS3000 How to Order VFS G 0 Symbol position single position double 3 position closed center 3 position exhaust center Port size 0 Rc Rc 3 8 Manual override Nil: Non-locking push type (Flush) Thread type Nil N Rc NPT T NPTF F G A : Non-locking push type (Extended) B : Locking type (Tool required) Option F: With foot bracket Mountable only for VFS position pressure center Reverse pressure: Can be used by external pilot specifications. Body (Pilot exhaust) 0: Individual EXH Light/Surge voltage suppressor Nil None Z With light/surge voltage suppressor S With surge voltage suppressor Indicator light is not available for grommet type. W/ surge voltage suppressor is available for grommet type only. Electrical entry G: Grommet E: Grommet terminal T: Conduit terminal D-Y: DIN terminal 30 : Common EXH VAC (50/60 Hz) 00 VAC (50/60 Hz) to 10 VAC (50/60 Hz) Manifold only 4 0 VAC (50/60 Hz) Pilot type 5 4 VDC Nil Internal pilot 6 1 VDC R External pilot 7 40 VAC (50/60 Hz). It will be 9 Other an individual external pilot. External pilot port: Body side. For 30 type, common external pilot (on manifold side). How to Order Pilot Valve Assembly SF VAC, 50/60 Hz 00 VAC, 50/60 Hz to 10 VAC (50/60 Hz) 4 0 VAC, 50/60 Hz 5 4 VDC 6 1 VDC 7 40 VAC, 50/60 Hz 9 Other DZ 1 Electrical entry, Light/Surge voltage suppressor G Grommet GS Grommet with surge voltage suppressor D DIN terminal DZ DIN terminal with light/surge voltage suppressor DO DIN terminal DOZ DIN terminal with light/surge voltage suppressor Y DIN terminal YZ DIN terminal with light/surge voltage suppressor YO DIN terminal YOZ DIN terminal with light/surge voltage suppressor T Conduit terminal TZ Conduit terminal with light/surge voltage suppressor E Grommet terminal EZ Grommet terminal with light/surge voltage suppressor Y: Conforming to DIN43650B standard DIN connector is not attached. Manual override Applicable model A side pilot operator for VFS B side pilot operator for VFS B side pilot operator for VFS A side pilot operator for VFS B side pilot operator for VFS330 3 B side pilot operator for VFS Nil Non-locking push type (Flush) A Non-locking push type (Extended) B Locking type (Tool required) C Locking type (Lever) 1 1 Individual pilot exhaust Common pilot exhaust
3 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Cylinder Speed Chart Body Ported Series VFS Conditions Average speed (mm/s) Use as a guide for selection. Please confirm the actual conditions with SMC Sizing Program. Bore size Series CJ Pressure 0.5 MPa Load factor 50% Stroke 60 mm Series CM Pressure 0.5 MPa Load factor 50% Stroke 300 mm Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CS1 Pressure 0.5 MPa Load factor 50% Cylinder stroke 1000 mm ø6 ø10 ø16 ø0 ø5 ø3 ø40 ø40 ø50 ø63 ø80 ø100 ø15 ø140 ø160 It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. Load factor: ((Load weight x 9.8)/Theoretical force) x 100% Body ported Series CJ Series CM Tube bore x Length T0604 x 1 m T1075 x 1 m VFS Speed controller AS3001F-06 AS4001F-10 Silencer AN00-0 Series MB Series CS1 T109 x 1 m AS4001F-1 AN0-0 Perpendicular, upward actuation Horizontal actuation VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN 3-8-7
4 Series VFS3000 Construction position position double Closed center 3 position closed center/exhaust center/pressure center Exhaust center Pressure center Component Parts No. q w e r Replacement Parts No. Description Body Spool/Sleeve End plate Piston Description Material Aluminum die-casted Stainless steel Resin Resin Material t Return spring Stainless steel y Pilot valve assembly u Detent assembly Note Platinum silver Black Part no. VFS310 VFS30 VFS330/340/350 VFS VFS Refer to How to Order Pilot Valve Assembly on page VFS3000-9A 3-8-8
5 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Position Single Grommet: VFS310- G Grommet, Grommet terminal, Conduit terminal, DIN terminal Foot bracket (F) Part no.: VFS3000-5A Manual override (Non-locking) -ø4.3 mounting hole 300 (Lead wire length) M5: External pilot port (For external pilot model) -ø6 mounting hole Solenoid valve VK VZ VF VFR VP4 VZS -ø4.3 mounting hole VFS 3-Rc 1/4, 3/8 -Rc 1/4 VS4 VQ7 EVS Grommet terminal: VFS310- E/EZ DIN terminal: VFS310- D/DZ/Y/YZ VFN With light/surge voltage suppressor (EZ) Lead wire O.D. Max. ø3.5 Light Applicable heavy-duty cord O.D. ø6 to ø8 (Y: ø4.7 to ø7) With light/surge voltage suppressor (DZ) Light -ø4.3 mounting hole Conduit terminal: VFS310- T/TZ -ø4.3 mounting hole Applicable heavy-duty cord O.D. ø6 to ø8 With light/surge voltage suppressor (TZ) Light ( ): Y, YZ -ø4.3 mounting hole 3-8-9
6 Series VFS3000 Position Double, 3 Position Grommet, Grommet terminal, Conduit terminal, DIN terminal Grommet: VFS30- G, VFS330- G, VFS340- G, VFS350- G 194 (3 position: 04) Manual override (Non-locking) -ø4.3 mounting hole M5: External pilot port (For external pilot model) 300 (Lead wire length) -ø4.3 mounting hole 3-Rc 1/4, 3/8 -Rc 1/4 Grommet terminal: VFS30- E/EZ VFS330- E/EZ VFS340- E/EZ VFS350- E/EZ Lead wire O.D. Max. ø (3 position: 04) DIN terminal: VFS30- D/DZ/Y/YZ VFS330- D/DZ/Y/YZ VFS340- D/DZ/Y/YZ VFS350- D/DZ/Y/YZ With light/surge voltage suppressor (EZ) Light Applicable heavy-duty cord O.D. ø6 to ø8 (Y: ø4.7 to ø7) 31 (3 position: 41) With light/surge voltage suppressor (DZ) Light -ø4.3 mounting hole Conduit terminal: VFS30- T/TZ VFS330- T/TZ VFS340- T/TZ VFS350- T/TZ -ø4.3 mounting hole Applicable heavy-duty cord O.D. ø6 to ø8 31 (3 position: 41) With light/surge voltage suppressor (TZ) ( ): Y, YZ Light -ø4.3 mounting hole
7 For details about certified products conforming to international standards, visit us at 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series VFS3000 Model position 3 position Type of actuation Single Double Closed center Exhaust center Pressure center Double check Compact yet provides a large flow capacity 3/8: C: 5.8 dm 3 /(s bar) Low power consumption: 1.8 W DC Easy maintenance types of sub-plates: Plug-in and non plug-in Plug-in type Non plug-in type JIS Symbol position Single Plug-in VFS3100 VFS300 VFS3300 VFS3400 VFS3500 VFS3600 Model Non plug-in VFS3110 VFS310 VFS3310 VFS3410 VFS3510 VFS3610 Port size Rc Flow characteristics 1 4/ (P A/B) 4/ 5/3 (A/B R1/R) C C [dm 3 /(s bar)] b Cv [dm 3 /(s bar)] b Cv Standard Specifications Option 0 or less 15 or less 50 or less Note 1) Based on JIS B 8375 (once per 30 days) for the minimum operating frequency. Note ) Based on JIS B (the value at supply press. 0.5 MPa). Note 3) The figures in the above list are for without sub-plate. In the case of with plug-in sub-plate and with non plug-in sub-plate, add 0.30 kg and 0.7 kg respectively. Note 4) Note 1) and Note ) are with controlled clean air. Double 3 position Closed center Exhaust center Pressure center Double check Valve specifications Electricity specifications Fluid Maximum operating pressure Minimum operating pressure Proof pressure Ambient and fluid temperature Lubrication Pilot valve manual override Shock/Vibration resistance Enclosure Allowable voltage fluctuation Coil insulation type Apparent power (Power consumption) AC Power consumption DC Electrical entry Inrush Holding Air/Inert gas 1.0 MPa 0.1 MPa 1.5 MPa 10 to 60 C (1) Non-lube () Non-locking push type (Flush) 150/50 m/s (3) Type E: Dustproof (Level 0), Type F: Dripproof (Level ), Type D: Splashproof (Level 4) (4) 100, 00 VAC, 50/60 Hz; 4 VDC 15 to +10% of rated voltage Class B or equivalent (130 C) (5) 5.6 VA/50 Hz, 5.0 VA/60 Hz 3.4 VA (.1 W)/50 Hz,.3 VA (1.5 W)/60 Hz 1.8 W (.04 W: With light/surge voltage suppressor) Plug-in type Non plug-in type Conduit terminal DIN terminal, Grommet terminal Note 1) Use dry air at low temperatures. Note ) Use turbine oil Class 1 (ISO VG3), if lubricated. Note 3) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Note 4) Based on JIS C 090. Note 5) Based on JIS C Pilot type Manual override Main valve Pilot valve Porting specifications Option Note) Operating pressure: 0 to 1.0 MPa Pilot pressure: 0.1 to 1.0 MPa Max. operating cycle (cpm) External pilot Note) Direct manual override type Non-locking push type (Extended), Locking type (Tool required), Locking type (Lever) 110 to 10, 0, 40 VAC (50/60 Hz) 1, 100 VDC Bottom ported With light/surge voltage suppressor (1) () Response time (ms) (3) Weight (kg) VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN
8 Series VFS3000 Body type O: Plug-in type sub-plate How to Order Electrical entry F: Plug-in type conduit terminal Porting specifications Nil Side ported B Bottom ported Plug-in VFS F 0 Port size Nil Without sub-plate 0 Rc Rc 3 8 For bottom ported, Rc 1 4 is only available. Thread type Nil N T F Rc NPT NPTF G Non plug-in VFS3 1 1 D 0 Option Nil Z None With light/surge voltage suppressor Pilot valve Manual override Nil: Non-locking push type (Flush) position single Symbol 3 position pressure center Electrical entry E: Grommet terminal D: DIN terminal 1 5 A : Non-locking push type (Extended) position double 3 position double check position closed center 3 position exhaust center Reverse pressure: Can be used by external pilot specifications. Body type 1: Non plug-in type sub-plate Pilot type Nil R VAC, 50/60 Hz 00 VAC, 50/60 Hz 110 to 10 VAC, 50/60 Hz 0 VAC, 50/60 Hz 4 VDC 1 VDC 40 VAC, 50/60 Hz Other Internal pilot External pilot B : Locking type (Tool required) C : Locking type (Lever) Body Option 0 Standard 1 Direct manual override How to Order Pilot Valve Assembly SF4 1 F 30 Symbol Rated voltage Symbol Manual override VAC, 50/60 Hz Nil 00 VAC, 50/60 Hz to 10 VAC, 50/60 Hz 4 A 0 VAC, 50/60 Hz 5 4 VDC 6 B 1 VDC C Refer to page for voltage conversion VAC, 50/60 Hz 9 Other Manual override Non-locking push type (Flush) Non-locking push type (Extended) Locking type (Tool required) Locking type (Lever)
9 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series VFS3000 Cylinder Speed Chart System A B System A B System Components Solenoid valve Series VFS3000 Rc 1 4 Series VFS3000 Rc 3 8 Speed controller AS (S = 4 mm ) AS40-03 (S = 73 mm ) Double Check Spacer/Specifications Specifications Can hold an intermediate cylinder position for an extended time If the double check spacer with a built-in double check valve is combined, it will enable the cylinder to stop in the intermediate stroke and maintain its position for a long time without being affected by the leakage between the spools. Double check spacer Plug-in type Average speed (mm/s) Use as a guide for selection. Please confirm the actual conditions with SMC Sizing Program. Bore size Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CS1 Pressure 0.5 MPa Load factor 50% Cylinder stroke 1000 mm ø40 ø50 ø63 ø80 ø100 ø15 ø140 ø160 ø180 ø00 Non plug-in type Silencer SGP (Steel pipe) Port size x Length AN00-0 (S = 35 mm ) 6A x 1 m AN (S = 60 mm ) 10A x 1 m Double check spacer part no. Applicable valve model Leakage (cm 3 /min) Plug-in type VVFS3000-A-1 VFS3400- F Solenoid one side energized Solenoid P both sides de-energized A B Supply pressure: 0.5 MPa Non plug-in type VVFS3000-A- VFS3410- D VFS3410- E Caution In the case of 3 position double check valve (VFS36 0), check the leakage from piping and fittings in between valve and cylinder by means of synthetic detergent solutions, and ensure that there is no such leakage found there. Also check the leakage from cylinder seal and piston seal. If there is any leakage, sometimes the cylinder, when valve is de-energized, can move without stopping at intermediate position. Be aware that if the exhaust side is restricted excessively, the intermediate stopping accuracy will decrease and will lead to improper intermediate stops. P EA 30 EB or less EA 30 EB or less EA 0 EB Perpendicular, upward actuation Horizontal actuation It is when the cylinder is extending that is meterout controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. Load factor: ((Load weight x 9.8)/Theoretical force) x 100% Check Valve Operation SUP side pressure P1 (MPa) Piston Cylinder side pressure (P) Operating range The combination of VFS31 10, VFS3 10 and double check spacer can be used as prevention for falling at the stroke end but cannot hold the intermediate position of the cylinder. 0 Check valve SUP side pressure (P1) Cylinder side pressure P (MPa) 0 VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN
10 Series VFS3000 Construction position single position double 3 position closed center/exhaust center/pressure center Closed center Exhaust center Pressure center Component Parts No. Description q Body w Sub-plate e Spool/Sleeve r Adapter plate t End plate y Piston u Junction cover i Light cover Material Aluminum die-casted Aluminum die-casted Stainless steel Resin Resin Resin Resin Resin Note Platinum silver Platinum silver Black Black Sub-plate Part No. 0 Plug-in VFS3000-P Non plug-in VFS3000-S- 03 Mounting bolt and gasket are not included. Part no. for mounting bolt and gasket BG-VFS3000 Replacement Parts No. Description Material Part no. VFS31 VFS3 VFS33 /34 /35 o!0 Return spring Gasket Stainless steel NBR VFS VFS VFS VFS VFS3000-0!1 Hexagon socket head screw Steel M3 x 3 M3 x 3 M3 x 3! Detent assembly VFS3000-9A!3 Pilot valve assembly Refer to How to Order Pilot Valve Assembly on page
11 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series VFS3000 Plug-in position single, 3 position closed center/exhaust center/pressure center/double check position single: VFS3100- F -ø5.6 mounting hole Rc 1/8 external pilot port (Only for external pilot) (B), 4(A) port Rc 1 8 (PE port) VK VZ Pilot valve manual override G 1/ electrical entry position double: VFS300- F 3 position closed center: VFS3300- F 3 position exhaust center: VFS3400- F 3 position pressure center: VFS3500- F -ø5.6 mounting hole With direct manual override 5-Rc 1 4, (3 position: 175) Light window At Fz 5-Rc 1 4 Bottom ported 3 position double check: VFS3600- F -ø5.6 mounting hole -ø5.6 mounting hole ( ): Rc 1 4 VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Pilot valve manual override 86.5 (3 position: 96.5) Light window At Fz With direct manual override Pilot valve manual override G 1/ electrical entry G 1/ electrical entry 5-Rc 1 4, Rc 1 4, 3 8 Light window At Fz With direct manual override ( ): Rc 1 4 ( ): Rc
12 Series VFS3000 Non Plug-in Position single/double, 3 position closed center/exhaust center/pressure center/double check position single: VFS3110- E, VFS3110- D -ø5.6 mounting hole Rc 1/8 external pilot port (Only for external pilot) (B), 4(A) port Rc 1 8 (PE port) Cable ø8 to ø10 Pilot valve manual override Light window At DZ, EZ -ø5.6 mounting hole With direct manual override 5-Rc 1 4 Bottom ported 5-Rc 1 4, 3 8 ( ): Rc 1 4 position double: VFS310- E, VFS310- D 3 position closed center: VFS3310- E, VFS3310- D 3 position exhaust center: VFS3410- E, VFS3410- D 3 position pressure center: VFS3510- E, VFS3510- D 3 position double check: VFS3610- E, VFS3610- D -ø5.6 mounting hole -ø5.6 mounting hole Applicable heavy-duty cord O.D. ø8 to ø10 Pilot valve manual override Light window at DZ, EZ Applicable heavy-duty cord O.D. ø8 to ø10 Pilot valve manual override With direct manual override 165 (3 position: 175) Light window At DZ, EZ With direct manual override 5-Rc 1 4, Rc, ( ): Rc 1 4 ( ): Rc
13 S OLENOID VALVES S ERIES NVFS.69 M O D E L NVFS3000 S Y M B O L S Position Number Of Type Port Size Cv Response Solenoid Plug-In (NPTF) Factor Time (ms) Single NVFS3100 1/ or less Position 3/8 Double NVFS300 1/ or less 3/8 Closed NVFS3300 1/4 1.8 Center 3/8 Exhaust NVFS3400 1/ Position Center 3/8 Pressure NVFS3500 1/4 1.8 Center 3/8 Perfect NVFS3600 1/ or less (Double Check) 3/8 1. T ECHNICAL SPECIFICATIONS S T ANDARD T ECHNICAL SPECIFICATIONS O PTIONAL Fluid Air and Inert Gas Pilot Type External Pilot Type Max Operating Pressure 150 PSI (1MPa) Manual Override Main Valve Direct Manual Override Type Min Operating Pressure PSI (0.15MPa) Pilot Operator Non Locking Push Type (Extended), Valve Ambient & Fluid Temperature 14~140ºF (-10~60ºC) Lock Type (Tool), Lock Type (Lever) Lubrication Not Required Voltage AC 100V50/60Hz, 00V50/60Hz Pilot Operator Manual Override Non Locking Push Type (Flush) DC 6V, 48V, 100V Protection Construction Dust Proof Porting Bottom Ported Subplate Rated AC 110VAC50/60Hz, 0V50/60Hz, 4V50/60Hz Option W/Indicator Light & Surge Voltage DC 1V, 4V Voltage Suppressor Allowable Voltage Range -15 ~ 10% Rated Voltage Coil Insulation Class B or Equivalent Electrical Apparent Power AC InRush 5.0VA/60Hz, 5.6VA/50Hz (Power Consumption) Holding.3VA(1.5W)/60Hz, 3.4VA(.1W)/50Hz Power Consumption DC 1.8W Electrical Entry Plug In Conduit Terminal (Base Access) S EE INSIDE FRONT COVER FOR DETAILS OF YOUR LOCAL SALES OFFICE FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT, REQUEST CATALOG REFERENCE N33
14 .70 S OLENOID VALVES S ERIES NVFS H O W T O O R D E R NVFS3000 NVFS 3 0 F P OSITION 1 Position Single Position Double 3 3 Position Closed Center 4 3 Position Exhaust Center 5 3 Position Pressure Center 6 3 Position Perfect B ODY T YPE 0 Plug-In Type P ORT S IZE - Without Subplate 0T 1/4 NPTF 03T 3/8 NPTF* * Not available for Bottom Ported P ORTING - Side *B Bottom Note) *1/8 NPTF Only M ANUAL O PTION 0 Standard 1 Std & Direct Manual (Special Order) P ILOT O PERATOR - Internal R External (Special Order) V OLTAGE 1 100VAC (Special Order) 00VAC (Special Order) 3 110VAC 4 0VAc 5 4VDC 6 1VDC 9 Others (Special Order) E LECTRICAL E NTRY F Through Base M ANUAL O VERRIDE - Non Locking Push Type (Flush) *A Non Locking Push Type (Extended) B Lock Type (Screw Type) *C Lock Type (Lever) Note) * Special Order O PTIONS - None Z With Indicator Light and Surge Voltage Suppressor H O W T O O R D E R M ANIFOLD FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT, REQUEST CATALOG REFERENCE N33
5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model 2 position 3 position
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position
More information5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range
For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR2 JIS Symbol type
More informationGrommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC
5 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Body Ported Base Mounted Series S000 S000 S000 S000 S000 S4000 S5000 Sonic conductance C [dm /s bar)] 4/ 5/(A/B R/R) Single Double.8.4
More informationManifold Specifications Stacking Type
Specifications Stacking Type Keeps environmental air clean from pilot exhaust Use of the VV5FS- manifold can exhaust intensively the pilot exhaust gas to the base side, and can prevent environmental aggravation
More information5 Port Solenoid Valve
5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body
More informationManifold Specifications
Specifications Plug-in Type: With Terminal Block Since lead wires of solenoid valve are connected with the terminals on upper surface of terminal block, corresponding lead wires from power source can be
More information(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC
5 Port Pilot Operated Solenoid Valve Metal Seal Series VZS Series Variations Plug-in Type Base Mounted Type (With sub-plate) Non Plug-in Type Base Mounted Type (With sub-plate) Series Sonic conductance
More informationExhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)
5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body
More information5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure
For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Series 000 Compact and lightweight: 3 mm width Compact yet provides
More information5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal
Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage
More informationFlow characteristics Max. (1) b Standard Specifications. P Manual override.
Port Direct Operated Solenoid Valve Series 0 Metal Seal Model Number of positions (Single) (Double) ( position) JIS Symbol Model Port size Rc (Nominal size) 0-0 8 ( A) 0- ( 8A) 0-0 8 (0A) 0-0 8 ( A) 0-
More informationSeries VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4
Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double
More information5 Port Pilot Solenoid Valve Metal Seal. Configuration Voltage Electrical entry Option. Standard. 100V AC50/60Hz 200V AC50/60Hz 24V DC.
5 Port Pilot Solenoid Valve Metal Seal SeriesVFS Models and Variations Body ported Base mounted Series VFS000 VFS2000 VFS3000 VFS2000 VFS3000 VFS4000 VFS5000 Port Size Effective area (mm 2 ) (Nl/min) 8:
More informationSeries VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non
Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non
More information5 Port Solenoid Valve Direct Operated Poppet Type. Specifications
Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W
More information3 Port Solenoid Valve Direct Operated Poppet Type
3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage
More information3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.
3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118
More information5 Port Solenoid Valve Direct Operated Poppet Type. Specifications
Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W
More information5 Port Pilot Solenoid Valve Rubber Seal
5 Port Pilot Solenoid Valve Rubber Seal VF1000/3000/5000 Large flow capacity, Yet compact size. Low power consumption. 1.8WDC Exhausting equipment for pilot valve not required. Common exhaust for main
More information3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot
3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in
More informationNAMUR Interface 5 Port Solenoid Valve
NAMUR Interface 5 Port Solenoid Valve Series VFN000N 5 5 Specifications Valve Electrical entry Fluid Max. operating pressure Min. operating pressure Ambient and fluid temperature Lubrication Pilot operator
More information5 Port Solenoid Valve
Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size
More information3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option
Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable
More informationManifold Specifications
Series 00 Manifold Specifications Manifold Specifications Model Manifold type P(SUP)/R(EXH) Valve stations A port porting specifications Port size For internal pilot For external pilot Location Direction
More informationSeries VKF300 VV061 V100 S070 VQD VKF VK VT VS
Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing
More information5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted
Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted
More information5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC)
Port Solenoid Valve/Direct Poppet Rubber seal Series VK3000 Nl/min 147 Compact/Width 18 X Length 8 (mm) Low power consumption 4W DC (Standard) 2W DC (Energy saver) Standard copper free specification All
More informationRubber Seal VP300/500/700
Port Pilot Operated Poppet Rubber Seal 00/500/700 High flow capacity Cv1.0 (00), Cv. (500), Cv.0 (700) Low power consumption: 1.8W(DC) Possible to use as either selector valve or divider valve Changeable
More informationSeries VQZ1000/2000/3000 Single Unit
+- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body
More informationSeries VP3145/3165/3185
Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes
More information5 Port Solenoid Valve
ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and
More information5 Port Solenoid Valve
ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high
More informationSeries VP3145/3165/3185
Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to
More informationSeries SV1000/2000/3000/4000
Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double
More informationISO Standard Solenoid Valve/SIZEq Rubber Seal Series VP7 6
ISO Standard Solenoid Valve/SIZq Rubber Seal Series VP7 6 VP7 6 FPG D VP7 6 FG D position position Single solenoid (FG-S) Double solenoids (FG-D) Reverse pressure (YZ-S) Reverse pressure (YZ-D) Closed
More informationPower Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.
Power Valve: Regulator Valve Series 1 Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control
More informationPower Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.
Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control
More informationFluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single
Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position
More information2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating
/ ort Solenoid Valve ubber Seal Series SYJ000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Specifications JIS Symbol port port (manifold) position
More informationManual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry
Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal
More informationBody width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.
High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure of 0.5MPa, subject to clean, dry air) 4 Port Direct
More information3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option
3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity
More informationVacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm
4 Port Direct Operated Poppet Solenoid Valve Series D1000 High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure
More informationPower Valve: Economy Valve. Standard Specifications. Model VEX55-04
Three functions (pressure regulator, switching valve, and speed controller) are provided by a single valve. The conventional valve combination circuit has been condensed into a single valve. A large capacity
More information5 Port Solenoid Valve
ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series
More informationSeries VQ Port Solenoid Valve
Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors
More information2.26 S OLENOID VALVES S ERIES VQ1000
2.26 S OLENOID VALVES 5 PORT M ETAL S EAL/RUBBER S EAL U LTRA H IGH S PEED S OLENOID VALVE High Speed Response from new Solenoid Design. Long Life: Over 200 Million Cycles can be with Patent Pilot Valve
More information3 Port Solenoid Valve
3 ort Solenoid Valve Series VKF300 ubber Seal Direct Operated oppet Type Compact yet provides a large flow capacity Body width 8 mm vailable in vacuum applications ( 0. ka) Can be used in vacuum/release
More information1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions
Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]
More information5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type. Closed Center DS3330/DS3300. How to Order - Body Ported Type
5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type COMPACT SIZE AND LIGHT WEIGHT LARGE FLOW CAPACITY LOW POWER CONSUMPTION DESIGNED FOR NON-LUBRICATED SERVICE DV000 Symbol Single DS330/ How
More informationPilot Operated 2 Port Solenoid Valve for Dry Air
Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible
More information3 Port Solenoid Valve
Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly
More informationSeries SYA3000/5000/7000
1 Port Air Operated Valve Series SYA000/000/7000 Body ported Base mounted Base mounted How to Order A, B port size Thread type Thread piping (Inch size) Nil Rc Symbol Port size Applicable series Symbol
More informationBase Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer
Base Mounted Metal Seal/Rubber Seal VQ Built-in silencer, direct exhaust Space-saving profile All pilot valves are compactly mounted on one side. The space-saving design of mounting all fittings on one
More informationISO Interface Solenoid Valve/SIZEq Metal Seal. Standard Specifications. Fluid Operating pressure. Ambient and fluid temperature
ISO Interface Solenoid Valve/SIZEq Metal Seal SeriesVS7-6 VS7-6-FPG-D VS7-6-FG-D Accessories Mounting bolt (with washer) Packing Indicator Iight Optional Specifications VS7-6-FG-S Note: Please note that
More information5 Port Air Operated Valve
Port ir Operated Valve Series VF000/000/000 RoHS 22- Series VF000/000/000 Model Selection by Operating Conditions q ir Operated Valve: Single Unit Series Sonic conductance C[dm /(s bar)] Type of actuation
More informationPilot Operated 2 Port Solenoid Valve for Dry Air
Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0
More information3 Port Solenoid Valve
Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series
More informationManifold Specifications
Specifications Specifications Base mounted VVFR-01 VVFR- VVFR-0 Wiring With terminal block With multi-connector With D-sub connector Grommet terminal DIN terminal Grommet Grommet terminal Conduit terminal
More informationRubber Seal 5 Port Pilot Type/Body Ported Type. Symbol. How to Order
Rubber Seal 5 Port Pilot Type/Body Ported Type DS5420- GC- COMPACT SIZE AND LIGHT WEIGHT LARGE FLOW CAPACITY LOW POWER CONSUMPTION DESIGNED FOR NON-LUBRICATED SERVICE DS5320- G- DS5220- G- Symbol Single
More information0.35 W (Without light)
Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:
More information3 Port Air Operated Valve
Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation
More informationSoft Start-up Valve. AV2000/3000/4000/5000 Series
Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off
More information3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum
3 Port Direct Operated Poppet Rubber Seal Series 307 Large Flow Capacity, yet Compact Size. Dimensions (W X H X D) 30 X 54.5 X 33 307 Nl/min 206.02 or more, 1/4 Low Power Consumption /VO307 4.8W DC/Standard
More information4/5 Port Solenoid Valve
ubber Seal / ort Solenoid Valve Series 000 / 000 / 000 [Option] SJ SY SV SZ V S000 VQ VQ VQ VQC VQZ SQ VFS VF VQ Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread
More information10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry
Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available
More informationSeries AV2000/3000/4000/5000
Soft Start-up Valve Series AV/3/4/5 Series introduced! A start-up valve that gradually increases supply pressure during start up and rapidly exhausts system air when the supply air is shut off AC AV AU
More informationSpecifications. Fluid Ambient and fluid temperature ( C)
Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication
More informationISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I
ISO Standard Solenoid Valve Series VQ7-6/7-8 (Size ) (Size ) Conforms to ISO Standard /I.0- Ideal for driving cylinders up to Large flow capacity ø00 (VQ7-6, Size ) ø60 (VQ7-8, Size ) Nl/min VQ7-6: 668.
More informationISO Interface Solenoid Valve/SIZEq Metal Seal. Standard Specifications. Fluid Operating pressure. Ambient and fluid temperature
ISO Interface Solenoid Valve/SIZq Metal Seal SeriesVS7-6 VS7-6-FPG-D VS7-6-FG-D Accessories Mounting bolt (with washer) Packing Indicator Iight Optional Specifications VS7-6-FG-S Note: Please note that
More information4/5 Port Solenoid Valve
CT.ES8 / ort Solenoid Valve Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M.7 to M2. 앬 Flow Characteristics Series Cover (stainless
More information5 Port Solenoid Valve
Metal seal Port Solenoid Valve Series VQ Rubber Seal Space-saving profile Clean space saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less
More informationHow to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1
Port Solenoid Valve Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Non plug-in manifold 0 0 S 60 Stations stations 0 stations SUP/EXH
More information4 Port Solenoid Valve
Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean
More informationCoolant Valve. Air Operated/External Pilot Solenoid
Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) lange type (3 to ) Low water hammer or details, refer to page
More informationPower Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.
Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control
More information4 Port Solenoid Valve
Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean
More informationSeries SY3000/5000/7000
Type20P 5 Port Solenoid Valve ody Ported Manifold ar Stock Type/Flat Ribbon Cable Series SY3000/5000/7000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 5 20P 05 Manifold series 3 SY3000
More informationISO Interface Solenoid Valve/SIZEq Metal Seal. Standard Specifications. Fluid Operating pressure. Ambient and fluid temperature
ISO Interface Solenoid Valve/SIZq Metal Seal SeriesVS7-6 VS7-6-FPG-D VS7-6-FG-D Accessories Mounting bolt (with washer) Packing Indicator Iight Optional Specifications VS7-6-FG-S Note: Please note that
More informationPower Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit
CT.EUS8 UK ower Consumption / ort Solenoid Valve With ower Saving Circuit Series SYJ000/000/7000 Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced
More informationATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry
Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 044 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000 racket
More informationCoolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations
Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) type (3 to ) Low water hammer or details, refer to page 07. Large
More informationProcess Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control
Process Series Port For Compressed Air and Air-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Cylinder actuation by external air he balance poppet
More informationExclusively for air pressure system and air-hydro circuit control
Process Valve Series Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external
More informationATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry
TEX Compliant Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 44 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000
More information2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control
Process Valve Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external pilot
More informationRubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot
ubber seal ort ilot Solenoid Valve Series SYJ00 Specifications efer to www.smcworld.com for details of products compatible with overseas standards. Body ported Base mounted Fluid Operating pressure range
More informationProcess Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control
Process Valve: Port Valve For Compressed ir and ir-hydro Circuit Control Series VN Style VN -6 VN -8 8 VN - 3 8 VN - 5 VN -5 VN3-0 3 0 Note) This product cannot be used for water application. JIS Symbol
More informationHigh Pressure Coolant Valve
High Pressure Coolant Valve Series.5 MPa, 7.0 MPa Corresponding to high speed grinding and long drilling processes Coolant valve for high pressure coolant liquid (up to.5 MPa or 7.0 MPa) that is ideal
More information10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection
Rubber Seal Port Solenoid Valve Series SJ000/000 Cassette Type Manifold 0 mm 7. mm (SJ000) 0 mm (SJ000) Non plug-in type Individual wiring manifold SJ000 SJ000 Can be mounted together. Connecter connection
More informationSeries SYA3000/5000/7000
Port Air Operated Valve Series SYA000/000/7000 How to Order A, B port size Thread type Thread piping (Inch size) - Rc Symbol Port size Applicable series Symbol Port size Applicable series F G SYA000 N
More informationVacuum Release Valve with Restrictor
INFORMATION Series SY3/5 Plug-in Only for External Pilot Vacuum Release Valve with Vacuum suction and release can be controlled with a single valve! PE Pilot EH port Flow rate adjustment of release air
More information1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110
Best 1 Pneumatics Transmitters Relay valve P. 1900 Side piping: 30 x 53 x 91 Bottom piping: 30 x 8 x 91 VR151 VR152 Effective area (mm 2 ) Number of ports Function 7 5 Metal Spool Shuttle valve P. 1902
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time
More information