3 Port Solenoid Valve

Size: px
Start display at page:

Download "3 Port Solenoid Valve"

Transcription

1 ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M. V3 Cover (stainless steel) Flow Characteristics Series SYJ300 SYJ00 SYJ700 Flow characteristics C [dm 3 /(s bar)] b Cv

2 ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 Variations Series ort size Sonic conductance C [dm 3 /(s bar)] Type of actuation Voltage Electrical entry Option Light/surge voltage suppressor Manual override SYJ300 Effective area 0.9 mm 3 ( ) Grommet Body ported.137 SYJ ( ) + L plug connector Base mounted.1386 SYJ SYJ SYJ SYJ ( ) ( ) 1. 3 ( ) N.C. N.O. For DC VDC 1 VDC 6 VDC VDC 3 VDC For C 0 0 VC 60 Hz 0 1 VC 60 Hz 0 00 VC 60 Hz 0 0 VC 60 Hz + + M plug connector DIN terminal (SYJ00, 700 only) M8 connector For DC With surge voltage suppressor With light/surge voltage suppressor Note) For C With light/surge voltage suppressor Nonlocking push type ush-turn locking slotted type ush-turn locking lever type, 1/.7 3 ( ).10 Note) ll C voltage models have built-in surge voltage suppressor. 1370

3 Series SYJ300/00/700 Manifold Variations port size Valve series port location, ports size M3 M With one-touch fitting pplicable tubing O.D. ø ø6 ø8 N3 N7 N9 Body ported Base mounted SYJ SYJ SYJ700.1 SYJ SYJ SYJ700.1 Top Top Top Side Bottom Side Bottom Side 1/ 1/ 1/ Note 1) Note ) Note 1) Note 1) Note 1) Note 1) Only for internal pilot Note ) Only for external pilot Base mounted Base mounted Base mounted Body ported Body ported Body ported Series SYJ300 Series SYJ00 Series SYJ700 SYJ VQZ V VG V3 1371

4 ubber Seal 3 ort ilot Solenoid Valve Series SYJ300 Specifications JIS Symbol Body ported Base mounted Fluid Operating pressure range (Ma) Internal pilot ir 0.1 to 0.7 mbient and fluid temperature ( C) Note 1) esponse time ms (at 0. Ma) Max. operating frequency (Hz) Manual override (Manual operation) ilot exhaust method Lubrication Mounting orientation Shock/Vibration resistance (m/s Note ) ) Enclosure to 0 (No freezing. ) 1 or less Non-locking push type, push-turn locking slotted type, push-turn locking lever type Individual exhaust for the pilot valve, common exhaust for the pilot and main valve Not required Unrestricted 10/30 Dust proof ( M8 connector conforms to I6.) Based on IEC609 Note 1) Based on dynamic performance test, JIS B (Coil temperature: 0 C, at rated voltage, without surge voltage suppressor.) Note ) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Value in the initial state) Vibration resistance: No malfunction occurred in one sweep test between and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Value in the initial state) Solenoid Specifications Internal pilot SYJ31 SYJ3 () 1 3 ()() External pilot SYJ31 SYJ3 () 1 3 ()() () 1 3 () () () 1 3 () () Made to Order (For details, refer to pages 1 to 13.) Electrical entry Coil rated voltage (V) ower consumption (W) pparent power (V) DC C Surge voltage suppressor Indicator light DC C 0 /60 Hz llowable voltage fluctuation Standard With power saving circuit 0 V 1 V [11 V] 00 V 0 V [30 V] Grommet (G), (H), L plug connector (L), M plug connector (M), M8 connector (W), 1, 6,, 3 0, 1, 00, 0 ±% of rated voltage 0.3 (With light: 0.) 0.1 (With light only) 0.78 (With light: 0.81) 0.86 (With light: 0.89) [0.9 (With light: 0.97)] 1.18 (With light: 1.) 1.30 (With light: 1.3) [1. (With light: 1.6)] Diode (varistor when non-polar types) In common between 1 VC and 11 VC, and between 0 VC and 30 VC. For 11 VC and 30 VC, the allowable voltage is 1% to +% of rated voltage. S, Z and T type (with power saving circuit) should be used within the following allowable voltage fluctuation range due to a voltage drop caused by the internal circuit. S and Z type: VDC: 7% to +% 1 VDC: % to +% T type: VDC: 8% to +% 1 VDC: 6% to +% LED 137

5 ubber Seal 3 ort ilot Solenoid Valve Series SYJ300 Flow Characteristics/Mass Valve model Body ported Base mounted (with sub-plate) SYJ31 SYJ3 SYJ31 SYJ3 Flow characteristics Type of ort 1 ( ) 3 ( ) actuation size C [dm 3 /(s bar)] b Cv C [dm 3 /(s bar)] b Cv N.C. N.O. N.C. N.O Note) Value for DC. dd 1 g for C. ( ): Without sub-plate Effective area (mm ) 0.9 Grommet 3 3 (3) Mass (g) Note) L/M plug connector 33 (33) M8 connector 37 8 (37) External ilot SYJ300 ilot valve pressure is supplied separately from the main valve pressure through the use of a separate supply port. It can be used in the vacuum (up to 0 ka) or low pressure line with 0.1 Ma or less. Specifications pplicable model Operating pressure range Ma Base mounted (SYJ31, SYJ3) Main pressure 0 ka to 0.7 External pilot pressure 0.1 to 0.7 Mark, port port (External pilot) port Note 1) For manifold base, refer to page Note ) External pilot type body ported valves (SYJ3 ) can only be used on the manifold. SYJ VQZ V VG V3 1373

6 Series SYJ300 3 port (For manifold type 0, 0) Type of actuation 1 Normally closed Normally open How to Order ated voltage DC Body ported SYJ3 1 M M3 6 V S VDC 1 VDC 6 VDC VDC 3 VDC C ( 0 /60 Hz) 1 0 VC 00 VC 3 1 VC [11 VC] 0 VC [30 VC] For type W, DC voltage is only available. Light/surge voltage suppressor Nil Without light/surge voltage suppressor S With surge voltage suppressor Z With light/surge voltage suppressor With surge voltage suppressor (Non-polar type) U With light/surge voltage suppressor (Non-polar type) For C voltage valves there is no S option. It is already built-in to the rectifier circuit. For type, U, DC voltage is only available. ower saving circuit is only available in the "Z" type. Bracket Nil: Without bracket F : With bracket Bracket Bracket is mounted. Brackets cannot be retrofitted. External pilot type is not available. Base mounted 3 port For sub-plate style, manifold type 1, S1,, S,, S Body option Nil: Individual pilot exhaust type port, E port M: Common exhaust for the pilot and main valve SYJ3 1 M Coil specifications Nil Standard With power saving circuit T (, 1 VDC only) ower saving circuit is not available in the case of W type. Electrical entry ort size, 1, 6,, 3 VDC/0, 1, 00, 0 VC, 1, 6,, 3 VDC Grommet L plug connector M plug connector M8 connector G: Lead wire length 300 mm + L: With lead wire (Length 300 mm) + M: With lead wire (Length 300 mm) + Nil: Without sub-plate (With gasket and screws) MN: Without lead wire + M: M port With sub-plate WO: Without connector cable CE-complaint Nil Q CE-complaint CE-compliant: For DC only. Manual override Nil: Non-locking push type port, E port ilot valve exhaust is centralized to main valve. H: Lead wire length 600 mm LN: Without lead wire LO: Without connector MO: Without connector W : With connector cable Note 1) D: ush-turn locking slotted type : External pilot type SYJ3 is only for manifold use. Note) When placing an order for body ported solenoid valve as a single unit, mounting screws for manifold and gasket are not attached. Order them separately, if necessary. (For details, refer to page 1379.) LN, MN type: with sockets. efer to page 1 for the lead wire length of L and M plug connectors. efer to page 18 for the connector assembly with cover for L and M plug connectors. For connector cable of M8 connector, refer to page 19. M8 connector conforming to IEC is also available. efer to page 1 for details. Note 1) Enter the cable length symbols in. lease be sure to fill in the blank referring to page 19. E: ush-turn locking lever type

7 ubber Seal 3 ort ilot Solenoid Valve Series SYJ300 Construction e q t N.C. r () 1 3 ()() e N.O. q t () 1 3 () () r () () u u 1 () 3 () w 1 () 3 () w y y Component arts No. 1 3 Description Body iston plate End cover iston Spool valve assembly Material Zinc die-casted esin esin esin luminum, H-NB Note White White White eplacement arts No. 6 7 Description Sub-plate Note) ilot valve art no. SYJ (-Q) V111(T)- Note) dd suffix -Q for the CE-compliant product. Note Zinc die-casted How to Order ilot Valve ssembly V111 G Coil specifications Nil Standard With power T saving circuit (, 1 VDC only) ower saving circuit is not available in the case of W type. ated voltage VDC 6 1 VDC V 6 VDC S VDC 3 VDC 1 0 VC 0/60 Hz 00 VC 0/60 Hz 1 VC 0/60 Hz 3 [11 VC 0/60 Hz] 0 VC 0/60 Hz [30 VC 0/60 Hz] For type W, DC voltage is only available. CE-compliant: For DC only. For C voltage valves there is no S option. It is already built-in to the rectifier circuit. For and U, DC voltage is only available. ower saving circuit is only available in the Z type. Electrical entry G H L LN LO M MN MO WO W Light/surge voltage suppressor Nil S Z U Without light/surge voltage suppressor With surge voltage suppressor With light/surge voltage suppressor With surge voltage suppressor (Non-polar type) With light/surge voltage suppressor (Non-polar type) Grommet, 300 mm lead wire Grommet, 600 mm lead wire L plug connector M plug connector M8 connector With lead wire Without lead wire Without connector With lead wire Without lead wire Without connector Without connector cable With connector cable Note 1) For connector cable of M8 connector, refer to page 19. Note 1) Enter the cable length symbols in. lease be sure to fill in the blank referring to page 19. SYJ VQZ V VG V3 Since V111 is CE-compliant as standard, the suffix "-Q is not necessary. 137

8 - + Series SYJ300 Body orted [ ] for C Grommet (G), (H): SYJ3 - G H -M3 With bracket: SYJ3 - G H -M3-F x ø1.8 (For manifold mounting) [0.8] G: pprox. 300 H: pprox. 600 x ø3. (For mounting) Manual override ( port) (Light/surge voltage suppressor) 8 [3] [3] 8.6 [0.8] (, port) (Bracket) ø1. (E port) L plug connector (L): SYJ3 - L -M3 M plug connector (M): SYJ3 - M -M3 M8 connector (WO): SYJ3 - WO -M3 8. [60.7] pprox [3] 1.6 pprox [0.9] [6.1] 7.6 M8 x () 13. () 13. () efer to page 19 for dimensions with connector cable.

9 ubber Seal 3 ort ilot Solenoid Valve Series SYJ300 Base Mounted (With Sub-plate) [ ] for C Grommet (G), (H): SYJ3 - G H -M ( port) 1 11 x ø3. (For mounting) Manual override G: pprox. 300 H: pprox [0.8] (Light/surge voltage suppressor) [8.] ( port) 17. (, port) L plug connector (L): SYJ3 - L -M M plug connector (M): SYJ3 - M -M M8 connector (WO): SYJ3 - WO -M 1. [8.] 6.1 pprox [9.6] pprox M8 x 1 SYJ VQZ V 3 8. [60.7] [0.9] VG V efer to page 19 for dimensions with connector cable. 1377

10 Series SYJ300 Manifold Specifications Manifold Specifications Model Manifold type (SU), (EH) Valve stations port orting specifications ort size For internal pilot For external pilot Location Direction, port port port Note) Note) Only for external pilot Type 0 Type 0 Valve Top Type 1, S1 Type, S Type, S Single base/b mount Common SU/Common EH to 0 stations Base Side 1 /8 1 /8 C (One-touch fitting ø) Flow Characteristics Body ported for internal pilot Base mounted for internal pilot Body ported for external pilot Base mounted for external pilot Manifold Type SS3YJ3-0 SYJ3 Type SS3YJ3-1 S1 SYJ3 Type SS3YJ3--M SYJ3 Type SS3YJ3--C Type SS3YJ3-S-M SYJ3 Type SS3YJ3-S-C Type SS3YJ3-0 SYJ3 Type SS3YJ3--M Type SS3YJ3--C Type SS3YJ3-S-M Type SS3YJ3-S-C SYJ3 SYJ3 1(), 3() ort ort size Note) Value at manifold base mounted, position single acting () ort C C C C 1 ( ) C [dm 3 b /(s bar)] Flow characteristics Cv ( ) C [dm 3 b /(s bar)] Cv Effective area (mm ) How to Order Manifold (Example) Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base model no. (Example) SS3YJ set (manifold base) SYJ31-LZ-M3... sets (valve) SYJ set (blanking plate assembly) SS3YJ3--03-C... 1 set (manifold base) SYJ31-G... sets (valve) SYJ set (blanking plate assembly) The asterisk denotes the symbol for assembly. refix it to the part nos. of the solenoid valve, etc. 1378

11 ubber Seal 3 ort ilot Solenoid Valve Series SYJ300 Combinations of Solenoid Valve, Manifold Gasket and Manifold Base Blanking late ssembly Body ported (Type SYJ3 ()(-Q)) Base mounted (Type SYJ3 ()(-Q)) art no.: SYJ300--1(-Q) art no.: SYJ300--(-Q) ound head combination screw SY (M1.7 x 17, Matt nickel plated) ound head combination screw SY (M1.7 x 17, Matt nickel plated) ound head combination screw ound head combination screw Blanking plate Blanking plate Manifold gasket Manifold gasket pplicable base SS3YJ3-0(-Q) SS3YJ3-0(-Q) Manifold gasket SYJ Manifold base Manifold gasket SYJ300-- pplicable base Sub-plate SS3YJ3-1(-Q) SS3YJ3-S1(-Q) SS3YJ3-(-Q) SS3YJ3-S(-Q) SS3YJ3-(-Q) SS3YJ3-S(-Q) Manifold base pplicable base SS3YJ3-0(-Q) SS3YJ3-0(-Q) Manifold base pplicable base Sub-plate SS3YJ3-1(-Q) SS3YJ3-S1(-Q) SS3YJ3-(-Q) SS3YJ3-S(-Q) SS3YJ3-(-Q) SS3YJ3-S(-Q) Manifold base Note) dd suffix -Q for the CE-compliant product. Mounting screw tightening torques M1.7: 0.1 N m Use caution to the assembly orientation for solenoid valves, gasket and optional parts. SYJ VQZ V VG V3 1379

12 Series SYJ300 Manifold for Internal ilot Type Type 0 Type 1 port Type port, C Type port port port port port port port, C port port How to Order SS3YJ3 0 0 Stations How to Order Valve mounting direction ilot valve is opposite Nil the port side. ilot valve is on the S port side. How to Order Type S Valve mounting direction ilot valve is on the ilot valve is opposite Nil port side. the port side. ilot valve is on the S port side port port port port 0 How to Order : 0 stations : 0 stations M C N3 Nil F Bracket Without bracket With bracket SS3YJ3 1 0 M3 Stations 0 stations SS3YJ3 0 M How to Order Stations 0 stations : : 0 0 stations port size ø one-touch fitting ø/3" one-touch fitting SS3YJ : 0 Stations stations : 0 stations CE-complaint Nil Q CE-complaint CE-complaint Nil Q CE-complaint, port thread type Nil c F G N NT T NTF, port thread type Nil c 00F G 00N NT 00T NTF SS3YJ3 0 M : 0 : 0 stations, port thread type Nil c F G N NT T NTF pplicable solenoid valve SYJ31- -M3(-Q) SYJ31M- -M3(-Q) SYJ3- -M3(-Q) SYJ3M- -M3(-Q) pplicable blanking plate assembly efer to page Note) For more than stations, supply air to both sides of port and exhaust air from both sides of port. pplicable solenoid valve SYJ31- (-Q) SYJ31M- (-Q) SYJ3- (-Q) SYJ3M- (-Q) pplicable blanking plate assembly efer to page Note) For more than stations, supply air to both sides of port and exhaust air from both sides of port. ilot valve pressure is supplied separately from the main valve pressure through the use of a separate supply port. It can be used in the vacuum (up to 0 ka) or low pressure line with 0.1 Ma or less. Type 0 port Type (External pilot type) port,c port (External pilot) 1380 Type 1 Type port (External pilot) port port Type S1 ilot valve is on the port side. ( ) ( ) Manifold for External ilot Type port port Type S ilot valve is on the ( ) port side and is of the external pilot type. port,c pplicable solenoid valve SYJ31- (-Q) SYJ31M- (-Q) SYJ3- (-Q) SYJ3M- (-Q) pplicable blanking plate assembly efer to page CE-complaint Nil Q CE-complaint Note) For more than 8 stations, supply/exhaust air to/from both sides of port and port. pplicable solenoid valve SYJ31- -M3(-Q) SYJ3- -M3(-Q) pplicable blanking plate assembly efer to page CE-complaint Nil Q CE-complaint Note) For more than stations, supply/exhaust air to/from both sides of port and port. Valve mounting direction Stations ilot valve is opposite 0 stations Nil the port side. : : S ilot valve is on the port side. 0 0 stations port port size (External pilot) M port C N3 ø one-touch fitting ø/3" one-touch fitting port pplicable solenoid valve SYJ31- (-Q) SYJ3- (-Q) pplicable blanking plate assembly efer to page CE-complaint Nil Q CE-complaint Note) For more than 8 stations, supply/exhaust air to/from both sides of port and port.

13 ubber Seal 3 ort ilot Solenoid Valve Series SYJ300 Type 0 Manifold: Top orted/ss3yj3-0- Stations -00 (-F) [ ] for C Grommet (G) L 3. (6) (.3) (17.) (Bracket mounting screw) (1.7) x ø3. (For mounting) 1. ( port) (itch) = [0.8] x ø3. (For mounting) (, port) Manual override pprox. 300 (Lead wire length) (Station n) L (Station 1) 3. (Light/surge voltage suppressor) [8.] L plug connector (L) M plug connector (M) M8 connector (WO) 8. [60.7] [0.9] SYJ VQZ V pprox. 300 (Lead wire length).6 [9.6] M8 x VG V3 pprox. 300 (Lead wire length) [8.] efer to page 19 for dimensions with connector cable. Station n L

14 Series SYJ300 Type 1 Manifold: Side orted/ss3yj3-1- Stations -M3 [ ] for C Grommet (G) 6.1 Type S1 Manifold: Side orted (ilot valve is on the port side) / SS3YJ3-S1- Stations -M3 (Light/surge voltage suppressor) L 3. pprox. 300 (Lead wire length) 3. L 8.8 [1] x ø3. (For mounting) 8.8 [1] Manual override x ø3. (For mounting) 13 (, port) pprox. 300 (Lead wire length) (itch) =. (Station n) (Station 1) Manual override (itch) =.. (Station 1) (Station n) 1. [8.] [8.] 13 ( port) (itch) = (itch) =. ( port) L plug connector (L) M plug connector (M) M8 connector (WO) pprox. 300 (Lead wire length) 1. [8.] pprox. 300 (Lead wire length).6 [9.6] [60.9] 8.9 [1.1] efer to page 19 for dimensions with connector cable. Station n L 138 Station Station

15 ubber Seal 3 ort ilot Solenoid Valve Series SYJ300 Type Manifold: Side orted/ss3yj3-- Stations -M, C N3 [ ] for C Grommet (G) For M For C (Built-in one-touch fitting) N pprox [.1] [.] L (itch) =. 0. (Station 1) (Station n) (itch) =. (Light/surge voltage suppressor) Manual override x ø. (For mounting) 0 ( port) (, port) (, port) 8. [.] 1. (.) (Station 1) (Station n) (itch) =. 0 One-touch fitting ( port) pplicable tubing O.D.: ø, ø/3" L plug connector (L) M plug connector (M) M8 connector (WO) pprox [.] 33.1 pprox [66.6] [6] 3 [.] efer to page 19 for dimensions with connector cable. Type S Manifold: Side orted (ilot valve is on the port side) / SS3YJ3-S- Stations -M, C N3 Grommet (G) For M L For C (Built-in one-touch fitting) N3 (, port) 1 SYJ VQZ.9 [.1] 30.7 pprox. 300 (Station n) (itch) =. 1. (Station 1) x ø. (For mounting) (Light/surge voltage suppressor) (.) (Station n) (Station 1) (Light/surge voltage L suppressor) 1. V VG V3 Station n L Station [.] 33.1 ( port) (itch) = One-touch fitting (, B port) pplicable tubing O.D.: ø, ø/3" (itch) = Station

16 Series SYJ300 Type 0 Manifold: Top orted (External ilot Type)/SS3YJ3-0- Stations -00 [ ] for C Grommet (G).9 [.1] ( port) 30.7 L x ø. (For mounting) ( port) (, port) pprox. 300 (Lead wire length) (itch) =. L 18. Manual override (Station n) (Light/surge voltage suppressor) (Station 1) [.] L plug connector (L) M plug connector (M) M8 connector (WO) 6.8 [6] pprox. 300 (Lead wire length) 3 [.] [.] pprox. 300 (Lead wire length) 9.6 [66.6] M8 x efer to page 19 for dimensions with connector cable. Station n L L3 138 Station Station

17 ubber Seal 3 ort ilot Solenoid Valve Series SYJ300 Type Manifold: Side orted (External ilot Type)/SS3YJ3-- Stations -M, 33.1 C N3 [ ] for C Grommet (G) For M For C (Built-in one-touch fitting) N3 pprox. 300 L (Light/surge voltage suppressor) Manual override [.1] 30.7 ( port) 8. [.] (itch) =. 8 (Station 1) (Station n) x ø. (For mounting) 0. 0 (, port) (, port) 8. [.] 18. (.) (Station 1) (Station n) (itch) =..1 0 ( port) (itch) = One-touch fitting ( port) pplicable tubing O.D.: ø, ø/3" L plug connector (L) M plug connector (M) M8 connector (WO) pprox [.] 33.1 pprox [66.6] M8 x [.] [6] (itch) =. L efer to page 19 for dimensions with connector cable. Type S Manifold: Side orted (ilot valve is on the port side) / SS3YJ3-S- Stations -M, Grommet (G) For M Station n L Station [.1] pprox [.] ( port) (Station n) ( port) (itch) = (Station 1) Manual override x ø. (For mounting) For (.) C N3.1 0 C (Built-in one-touch fitting) N3 8. [.] (, port) One-touch fitting ( port) pplicable tubing O.D.: ø, ø/3" (Station n) (Station 1) (itch) = Station SYJ VQZ V VG V3

18 M8 Connector Conforming to IEC Series SYJ300/00/700 Made to Order How to Order Valve 3 port (Manifold types 0, 0, 1) Type of actuation 1 Normally closed Normally open Series 3 SYJ300 SYJ00 7 SYJ700 ated voltage DC 6 V S VDC 1 VDC 6 VDC VDC 3 VDC Light/surge voltage suppressor Nil S Z U M 01 Without light/surge voltage suppressor With surge voltage suppressor With light/surge voltage suppressor With surge voltage suppressor (Non-polar type) With light/surge voltage suppressor (Non-polar type) ort size (SYJ700 only) Made to Order Nil 0 Bracket Nil F Without bracket With bracket Body ported external pilot(efer to page 13.) 0 for Series SYJ300 is not available. Body ported Base mounted SYJ 1 WO M SYJ 1 WO 01 3 port Body option Sub-plate type, manifold types 0, 0, 1, 1, S1,, S,, S Nil M ilot valve individual exhaust Common exhaust type for main and pilot valve Electrical entry ort size External pilot Nil Without sub-plate SYJ3, SYJ, SYJ7 are only for manifold use. WO: Without connector W : With connector Note) M 01 0 Nil Q M port With sub-plate port With sub-plate 1/ port With sub-plate CE-complaint CE-complaint SYJ300 SYJ00 SYJ700 SYJ700 Thread type Nil c F G N NT T NTF How to Order ilot Valve ssembly Note) Enter the cable length symbols in. lease be sure to fill in the blank referring to page 19. Manual override Nil Non-locking push type D ush-turn locking slotted type E ush-turn locking lever type V111 WO ated voltage DC VDC 6 1 VDC V 6 VDC S VDC 3 VDC Light/surge voltage suppressor Nil Without light/surge voltage suppressor S With surge voltage suppressor Z With light/surge voltage suppressor With surge voltage suppressor (Non-polar type) U With light/surge voltage suppressor (Non-polar type) Electrical entry WO M8 connector W Without connector With connector Note) Note) Enter the cable length symbols in. lease be sure to fill in the blank referring to page Since V111 is CE-compliant as standard, the suffix "-Q is not necessary.

19 Series SYJ00/700 Made to Order For detailed specifications, delivery and pricing, please contact SMC. Body orted External ilot How to Order pplicable solenoid valve series/syj, SYJ7 SYJ 7 0 Entry is the same as standard products. Operating ressure ange Ma Operating pressure range ilot pressure range 0 ka to to 0.7 Dimensions SYJ00: 8 mm longer in total length SYJ700: 8 mm longer in total length External ilot ort Series SYJ00, SYJ700 ort size JIS Symbol Body ported N.C. () N.O. () 1 3 () () 1 3 () () SYJ VQZ V VG V3 13

20 Series SYJ300/00/700 Specific roduct recautions 1 Be sure to read before handling. efer to front matters 8 and 9 for Safety Instructions and pages 3 to 7 for 3// ort Solenoid Valve recautions. Warning Manual Override Operation When the manual override is operated, connected equipment will be actuated. Confirm safety before operating. Non-locking push type [Standard] ress in the direction of the arrow Solenoid Valve for 00, 0 VC Specifications Warning Solenoid valves with grommet and L/M type plug connector C specifications have a built-in rectifier circuit in the pilot section to operate the DC coil. With 00, 0 VC specification pilot valves, this built-in rectifier generates heat when energized. The surface may become hot depending on the energized condition; therefore, do not touch the solenoid valves. ush-turn slotted locking type [Type D] While pressing, turn in the direction of the arrow. If it is not turned, it can be operated the same way as the nonlocking type. Locked position When operating the locking type D with a screw driver, turn it gently using a watchmakers screw driver. [Torque: Less than 0.1 N.m] ush-turn locking lever type [Type E] While pressing, turn in the direction of the arrow. If it is not turned, it can be operated the same way as the nonlocking type. USH LOCK Common Exhaust Type for Main and ilot Valve ilot air is exhausted through the main valve body rather than directly to atmosphere. Suitable for applications where exhausting the pilot valve to atmosphere would be detrimental to the surrounding working environment. For use in extremely dirty environments where there is the possibility that dust could enter the pilot exhaust and damage the valve. Ensure that the piping of exhaust air is not too restrictive. Bracket For bracket attached styles of SYJ300, do not use it without bracket. Locked position LOCK USH When locking the manual override on the push-turn locking types (D, E), be sure to push it down before turning. Turning without first pushing it down can cause damage to the manual override and trouble such as air leakage, etc. 1

21 Series SYJ300/00/700 Specific roduct recautions Be sure to read before handling. efer to front matters 8 and 9 for Safety Instructions and pages 3 to 7 for 3// ort Solenoid Valve recautions. How to Use lug Connector 1. ttaching and detaching connectors To attach a connector, hold the lever and connector unit between your fingers and insert straight onto the pins of the solenoid valve so that the lever s pawl is pushed into the groove and locks. To detach a connector, remove the pawl from the groove by pushing the lever downward with your thumb, and pull the connector straight out. Cover Groove in Cover Groove in. Crimping of lead wires and sockets Strip 3. to 3.7 mm at the end of the lead wires, insert the ends of the core wires evenly into the sockets, and then crimp with a crimping tool. When this is done, take care that the coverings of the lead wires do not enter the core wire crimping area. Use an exclusive crimping tool for crimping. (Contact SMC for special crimping tools.) -+ Connector Hook Lever DC olarity display Socket Lead wire lug Connector Lead Wire Length Standard length is 300 mm, but the following lengths are also available. How to Order Connector ssembly For DC: SY0 30 For 0 VC: SY For 00 VC: SY0 30 For other voltages of C: SY Without lead wire: SY0 30 (with connector and of sockets only) How to Order Include the connector assembly part number together with the part number for the plug connector s solenoid valve without connector. E.) In case of 000 mm of lead wire For DC For C SYJ31-LO-M3 SYJ31-1LO-M3 SY SY Lead wire length Nil mm 600 mm 00 mm 100 mm 000 mm 00 mm 3000 mm 000 mm Core wire crimping area Socket Crimping area Core wire Lead wire 0. to 0.33 mm Max. cover diameter: ø1.7 mm Hook Insulation 3. ttaching and detaching sockets with lead wires ttaching Insert the sockets into the square holes of the connector (+, indication), and continue to push the sockets all the way in until they lock by hooking into the seats in the connector. (When they are pushed in, their hooks open and they are locked automatically.) Then confirm that they are locked by pulling lightly on the lead wires. Detaching To detach a socket from a connector, pull out the lead wire while pressing the socket s hook with a stick having a thin tip (approx. 1 mm). If the socket will be used again, first spread the hook outward. SYJ VQZ V VG V3 Socket Connector Hook Lead wire 1

22 Series SYJ300/00/700 Specific roduct recautions 3 Be sure to read before handling. efer to front matters 8 and 9 for Safety Instructions and pages 3 to 7 for 3// ort Solenoid Valve recautions. <For DC> Grommet, L/M lug Connector Standard type (with polarity) Surge voltage suppressor ( S) ed (+) Black () Surge Voltage Suppressor Diode to prevent reverse current With light/surge voltage suppressor ( Z) ed (+) Diode to prevent reverse current Coil Coil DIN Terminal With surge voltage suppressor (DS) Varistor With light/surge voltage suppressor (DZ) Varistor Coil Coil Connect the standard type in accordance with the +, polarity indication. (The non-polar type can be used with the connections made either way.) Since voltage specifications other than standard and 1 VDC do not have diodes for polarity protection, be careful not to make errors in the polarity. lease use caution regarding the allowable voltage fluctuation because there is about a 1 volt drop for a valve with polarity protection. (For details, refer to the solenoid specifications for the individual valve.) When wiring is done at the factory, positive (+) is red and negative () is black. With power saving circuit ower consumption is decreased by 1/ by reducing the wattage required to hold the valve in an energized state. (Effective energizing time is over 6 ms at VDC.) Operating rinciple Black () Non-polar type With surge voltage suppressor ( ) () (+) (+) () With light/surge voltage suppressor ( U) () (+) Electric circuit (with power saving circuit) LED 1 Black () 1: Starting current : Holding current 3 (In the case of SYJ T, the electric 7 wave form of energy saving type) V 0 V 0. W 0.1 W 0 W pplied voltage 6 ms Standard With power saving circuit ed (+) With the above circuit, the current consumption when holding is reduced to save energy. lease refer to the electric wave data to the right. lease be careful not to reverse the polarity, since a diode to prevent the reversed current is not provided for the power saving circuit. lease use caution regarding the allowable voltage fluctuation because there is about a 0. volt drop due to the transistor. (For details, refer to the solenoid specifications for the individual valve.) Timer circuit Varistor (+) () Varistor Diode Coil Coil Coil DIN terminal has no polarity. M8 Connector Standard type (with polarity) With light/surge voltage suppressor ( S) 1(+) (Type W) 3(-) 3 (Type W) Diode to prevent reverse current Non-polar type With surge voltage suppressor ( ) 1(-)(+) (Type W) Varistor 3(+)(-) 3 (Type W) Solenoid valve side pin wiring diagram (Ground) 1 3 Type W Coil Coil With light/surge voltage suppressor ( Z) 1(+) (Type W) 3(-) 3 (Type W) With light/surge voltage suppressor ( U) 1(-)(+) (Type W) Varistor 3(+)(-) 3 (Type W) 3 1 Type W Diode to prevent reverse current For the standard type, connect + to 1 and to 3 for Type W according to polarity, while + to and to 3 for Type W. lease be careful not to reverse the polarity, since a diode to prevent the reversed current is not provided for DC voltages other than and 1 VDC. lease use caution regarding the allowable voltage fluctuation because there is about a 1 volt drop for a valve with polarity protection. (For details, refer to the solenoid specifications for the individual valve.) The W-type valve cannot be grounded. Coil Coil 16

23 Series SYJ300/00/700 Specific roduct recautions Be sure to read before handling. efer to front matters 8 and 9 for Safety Instructions and pages 3 to 7 for 3// ort Solenoid Valve recautions. <For C> (There is no S type because the generation of surge voltage is prevented by a rectifier.) Grommet, L/M lug Connector With light ( Z) Surge Voltage Suppressor How to Use DIN Terminal. Secure the cord by fastening the ground nut. When making connections, take note that using other than the supported size (ø3. to ø7) heavy duty cord will not satisfy I6 (enclosure) standards. lso, be sure to tighten the ground nut and holding screw within their specified torque ranges. DIN Terminal With light (DZ) Varistor Coil Changing the entry direction fter separating the terminal block and housing, the cord entry can be changed by attaching the housing in the desired direction ( directions at 90 intervals). When equipped with a light, be careful not to damage the light with the cord s lead wires. Varistor Coil recautions lug in and pull out the connector vertically without tilting to one side. Note) Surge voltage suppressor of varistor has residual voltage corresponding to the protective element and rated voltage; therefore, protect the controller side from the surge. The residual voltage of the diode is approximately 1 V. DIN Terminal Type Y type Y DIN connector is a DIN connector conforming to the 8- mm standard pitch between DIN terminals. NL: Neon light Since a type D DIN connector has a 9.-mm pitch between DIN terminals, it is not interchangeable. Type D DIN connectors have the N indication at the end of rated voltage symbol. (For DIN connectors without lights, N is not indicated. lease refer to the name plate to distinguish.) Dimensions are the same as type D DIN connector. When replacing only the pilot valve assembly, V11- D is interchangeable with V11- Y. Do not replace V111 (G, H, L, M, W) to V11- Y (DIN terminal), or vice versa. How to Use DIN Terminal Connection 1. Loosen the holding screw and pull the connector out of the solenoid valve terminal block.. fter removing the holding screw, insert a flat head screwdriver, etc. into the notch on the bottom of the terminal block and pry it open, separating the terminal block and the housing. 3. Loosen the terminal screws (slotted screws) on the terminal block, insert the cores of the lead wires into the terminals according to the connection method, and fasten them securely with the terminal screws. Compatible cable Cord O.D.: ø3. to ø7 (eference) 0. mm, -core or 3-core, equivalent to JIS C 3306 Ground nut tightening torque 1.6 to. N m Washer Grommet (ubber) (ating symbol) efer to front matter 7. Terminal screw (3 locations) Tightening torque 0. to 0. N m Solenoid Valve Mounting Set screw Tightening torque 0. N m Housing (Light mounting location) Terminal block Notch Mount it so that there is no slippage or deformation in gaskets, and tighten with the tightening torque as shown below. Model SYJ300 SYJ00 SYJ700 Thread size M1.7 M. M3 Tightening torque 0.1 N m 0. N m 0.8 N m SYJ VQZ V VG V3 17

24 Series SYJ300/00/700 Specific roduct recautions Be sure to read before handling. efer to front matters 8 and 9 for Safety Instructions and pages 3 to 7 for 3// ort Solenoid Valve recautions. DIN Connector art No. <Type D> Without light With light ated voltage VDC 1 VDC 0 VC 00 VC 1 VC 0 VC <Type Y> Without light With light ated voltage DC V DC1 V 0 VC 00 VC 1 VC(11 VC) 0 VC(30 VC) Voltage symbol V 1 V 0 V 00 V 1 V 0 V Voltage symbol VN 1 VN 0 VN 00 VN 1 VN 0 VN Circuit Diagram with Light C circuit SY SY0-8-1 art no. SY SY SY SY SY SY art no. SY SY SY SY SY SY DC circuit Connector ssembly with Cover Connector assembly with dust proof protective cover. Effective to prevention of short circuit failure due to the entry of foreign matter into the connector. Chloroprene rubber for electrical use, which provides outstanding weather resistance and electrical insulation, is used for the cover material. However, do not allow contact with cutting oil, etc. Simple and unencumbered appearance by adopting round-shaped cord. How to Order SY0-68- Lead wire length Nil 300 mm mm 00 mm mm mm 00 mm mm mm Connector ssembly with Cover: Dimensions (0) Gray (6.9) () ed Black (ø.1) (8) NL : Neon light : esister LED : Light emitting diode : esister (8) (1.) L How to Order Enter the part number for a plug connector solenoid valve without connector together with the part number for a connector assembly with cover. Ex. 1) Lead wire length of 000 mm SYJ31-LOZ-M3 SY Ex. ) Lead wire length of 300 mm (standard) SYJ31-LZ-M3 Symbol for connector assembly with cover In this case, the part number for the connector assembly with cover is not required. 18

25 Series SYJ300/00/700 Specific roduct recautions 6 Be sure to read before handling. efer to front matters 8 and 9 for Safety Instructions and pages 3 to 7 for 3// ort Solenoid Valve recautions. 1. M8 connector types have an I6 (enclosure) rating, offering protection from dust and water. However please note: these products are not intended for use in water. Select a SMC connector cable (V ) or a F sensor type connector, with M8 threaded 3 pin specifications conforming to Nippon Electric Control Equipment ssociation Standard, NEC0 (IEC6097--). Make sure the connector O.D. is. mm or less when used with the Series SYJ300 manifold. If more than. mm, it cannot be mounted due to the size.. Do not use a tool to mount the connector, as this may cause damage. Only tighten by hand. (0. to 0.6 N m) 3. The excessive stress on the cable connector will not be able to satisfy the I6 rating. lease use caution and do not apply a stress of 30 N or greater. Failure to meet I6 performance may result if using alternative connectors than those shown above, or when insufficiently tightened. M8 Connector Connector cable Connector cable for M8 can be ordered as follows: How to Order 1. To order solenoid valve and connector cable at the same time. (Connector cable will be included in the shipment of the solenoid valve.) 3 SYJ 7 Electrical entry W1, W1: Cable length 300 mm W, W: Cable length 00 mm W3, W3: Cable length 00 mm W, W: Cable length 000 mm W7, W7: Cable length 000 mm Ex. 1) Cable length: 300 mm SYJ31-W1ZE-M3 Symbol for electrical entry Connector cable mounting Triangle mark rrow mark. To order connector cable only Connector dimensions Brown: 1 Blue: ø Black: L 3 Note) Connector cable should be mounted in the correct direction. Make sure that the arrow symbol on the connector is facing the triangle symbol on the valve when using SMC connector cable (V ). Be careful not to squeeze it in the wrong direction, as problems such as pin damage may occur. Cable length (L) art no. 300 mm V mm V mm V mm V mm V SYJ 33.9 VQZ V 1 VG V3 19

26 Series SYJ300/00/700 Specific roduct recautions 7 Be sure to read before handling. efer to front matters 8 and 9 for Safety Instructions and pages 3 to 7 for 3// ort Solenoid Valve recautions. eplacement of ilot Valve ilot valves in this series are improved to provide excellent energy saving results. However following this improvement, these new valves are no longer compatible with the conventional pilot valve used at the interface. Consult with SMC when you need to exchange these pilot valves, in the case of manual override (marked in orange) of the adapter plate. New type Manual override (Blue) B B Interface ilot valve (V111) dapter plate Conventional type Manual override (Orange) Interface ilot valve (SY11) dapter plate 130

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot ubber seal ort ilot Solenoid Valve Series SYJ00 Specifications efer to www.smcworld.com for details of products compatible with overseas standards. Body ported Base mounted Fluid Operating pressure range

More information

Series SYJ300/500/700

Series SYJ300/500/700 ort Solenoid Valve ubber Seal Series SYJ00/00/00 Low power consumption: 0.W (Without light) (Current draw: 1m at 4V DC) Completely interchangeable ilot exhaust with the previous series VJ00/00/00 and VZ00/00.

More information

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A) ort Solenoid Valve ubber Seal Series SY00 Low power consumption: 0.W (Standard, Without light) (Current draw: m at V DC) Large flow capacity style:0.7w (Current draw: m at V DC) Body width: 0mm 7.8 Nl/min

More information

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating / ort Solenoid Valve ubber Seal Series SYJ000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Specifications JIS Symbol port port (manifold) position

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve ubber Seal / ort Solenoid Valve Series 000 / 000 / 000 [Option] SJ SY SV SZ V S000 VQ VQ VQ VQC VQZ SQ VFS VF VQ Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series

More information

3 Port Solenoid Valve

3 Port Solenoid Valve 3 ort Solenoid Valve Series VKF300 ubber Seal Direct Operated oppet Type Compact yet provides a large flow capacity Body width 8 mm vailable in vacuum applications ( 0. ka) Can be used in vacuum/release

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve CT.ES8 / ort Solenoid Valve Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M.7 to M2. 앬 Flow Characteristics Series Cover (stainless

More information

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit CT.EUS8 UK ower Consumption / ort Solenoid Valve With ower Saving Circuit Series SYJ000/000/7000 Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced

More information

Example. U side. Stations SY5000

Example. U side. Stations SY5000 45 Type 5 ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN ail Mounted/Individual Wiring Series SY3000/5000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 3 45 05 U C6 Example

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

3 Port Air Operated Valve. SYJA300 Series. How to Order. Nil Without sub-plate. Type of actuation. Normally closed Normally open

3 Port Air Operated Valve. SYJA300 Series. How to Order. Nil Without sub-plate. Type of actuation. Normally closed Normally open 3 ort ir Operated Valve SYJ300 Series How to Order SYJ3 M3 Bracket Nil Without bracket F With bracket *The bracket is not mounted. *The bracket cannot be retrofitted later. SYJ3 Type of actuation Normally

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

Series VQZ1000/2000/3000 Single Unit

Series VQZ1000/2000/3000 Single Unit +- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body

More information

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000) 5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust

More information

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308 Cable ppendix Cable ppendix Multi-way cables The multi-pole connector cables used on SMC valves are common across several ranges. Cables are available in accordance with the MIL standard C-08 and also

More information

Series SYJ3000/5000/7000

Series SYJ3000/5000/7000 , ort Solenoid Valve ubber Seal Series SYJ000/000/7000 Low power consumption: 0.W(Without light) (Current draw: 1m at V DC) right color tone and state of the art design SY SYJ SX VK VZ VF VF V7 V Completely

More information

Series SV1000/2000/3000/4000

Series SV1000/2000/3000/4000 Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double

More information

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring Type4 SY000/000 ase Mounted Monifold Stacking Type/DIN ail Mounted Individual Wiring How to Order Manifold SSY 4 0 U C6 How to Order Valve Manifold ssembly Ordering example SY000 SY000 Valve stations 02

More information

3 Port 3 Position Valve

3 Port 3 Position Valve Port Position Valve Pilot Solenoid ir Operated ohs Intermediate stopping of cylinders * up to ø15 is possible. Pilot solenoid Manifold ir operated * For VEX 4, 00 mm/s, horizontal movement Power consumption:

More information

VQ1000. How to Order Manifold. Kit type

VQ1000. How to Order Manifold. Kit type - - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal

More information

4/5 Port Air Operated Valve. SYJA3000 Series. How to Order. (Manifold use only) Type of actuation. 2 position single. 3 position closed center

4/5 Port Air Operated Valve. SYJA3000 Series. How to Order. (Manifold use only) Type of actuation. 2 position single. 3 position closed center 4/ ort ir Operated Valve SYJ000 Series How to Order ody ported SYJ M racket Nil Without bracket F With bracket *Refer to page 47 for the details of the brackets. ase mounted (4 port) SYJ 2 0 (Manifold

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high

More information

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

More information

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I ISO Standard Solenoid Valve Series VQ7-6/7-8 (Size ) (Size ) Conforms to ISO Standard /I.0- Ideal for driving cylinders up to Large flow capacity ø00 (VQ7-6, Size ) ø60 (VQ7-8, Size ) Nl/min VQ7-6: 668.

More information

Series SYJ Way 4 and 5 Port. Rubber Seal Solenoid Pilot Valve

Series SYJ Way 4 and 5 Port. Rubber Seal Solenoid Pilot Valve N Way and ort Series SYJ000 ubber Seal Solenoid ilot Valve ODUCTS Interchangeable with the NVJ Series Low ower Consumption: 0.W ase Mounted/ody orted Configurations Manifolds with uilt-in One-Touch Fittings

More information

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000 D-sub Connector J Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000//000 Number of connectors: pins MIL-C-08 Conforming to JIS-X-0 --6 For details

More information

Vacuum / Release Unit

Vacuum / Release Unit Rubber Seal Vacuum / Release Unit Series VQD1000-V Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area Smooth detachment of a work piece without over-blow

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type20P 5 Port Solenoid Valve ody Ported Manifold ar Stock Type/Flat Ribbon Cable Series SY3000/5000/7000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 5 20P 05 Manifold series 3 SY3000

More information

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),

More information

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle. Multistage Ejector 112/212 Series Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus

More information

0.35 W (Without light)

0.35 W (Without light) Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:

More information

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A Type N SY/ ase ounted anifold Stacking Type/DIN Rail ounted Connector ox How to Order anifold SSY SY SY Specifications Symbol Specifications With connector box (CO spec.) N With connector box ( CO spec.)

More information

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Vacuum / Release Unit Series VQD1000-V Rubber Seal Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area [Option] Smooth detachment of a work piece without

More information

Series SY3000/5000 How to Order Manifold

Series SY3000/5000 How to Order Manifold Type N ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN Rail Mounted/Connector ox SY/ How to Order Manifold SSY SY SY Specifications Symbol Specifications With connector box (COM spec.) N With

More information

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles ort Solenoid Valve: ase Mounted Metal Seal/Rubber Seal Series Space and capacity saving ilot valve is gathered at one side. Space saving design which does not have any protrusions. Space saving Capacity

More information

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC Base Mounted Series VQZ00/00/00 VQZ00/00 / How to Order Valve Made to Order (For details, refer to page 9 and 4.) VQZ 5 5 M Series VQZ00 body width 5 mm VQZ00 body width 8 mm Type of actuation 4 N.C. N.O.

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry

More information

Terminal Block Box (Spring Type) SY3000/5000/7000 Series

Terminal Block Box (Spring Type) SY3000/5000/7000 Series INFORMATION 5 ort olenoid alve Terminal lock ox (pring Type) Y3000/5000/7000 eries Compact RoH Height 6.7 mm shorter (Approx. 9% reduction) Installation area of the terminal block box Reduced by approx.

More information

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot 3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in

More information

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Vacuum Release Valve with Restrictor Series SJ3A6 SJ Plug-in Type Connector Connection P.86 D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Non Plug-in Type Individual

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type1P Type2P 5 Port Solenoid Valve ase Mounted Manifold ar Stock Type/Flat Ribbon Cable Series /5000/000 How to Order Manifold Type 1P/Compact style SS5Y 5 1P 05 C8 Manifold series 3 5, port size Thread

More information

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is. Port Solenoid Valve Series VQ 00 Unprecedented high speed, stable response, and extra-long service life. ON:.ms, OFF: ms, Dispension accuracy ±ms (With indicator light and surge voltage suppressor; supply

More information

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm 4 Port Direct Operated Poppet Solenoid Valve Series D1000 High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure

More information

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S. High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure of 0.5MPa, subject to clean, dry air) 4 Port Direct

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Series 000 Compact and lightweight: 3 mm width Compact yet provides

More information

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection Rubber Seal Port Solenoid Valve Series SJ000/000 Cassette Type Manifold 0 mm 7. mm (SJ000) 0 mm (SJ000) Non plug-in type Individual wiring manifold SJ000 SJ000 Can be mounted together. Connecter connection

More information

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold Port Solenoid Valve VV00 Series Highly Integrated Unit Manifold po ted - pera irect-o d station es on rt valv ally ividu Ind wired n be ve ca val d. adde ector Con-inn connection) lug (For p ø connection

More information

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Soft Start-up Valve. AV2000/3000/4000/5000 Series Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off

More information

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type. Series -S00 ompact Direct Operated Port Solenoid Valve ontrol Valves ase mounted ody ported lean Series lean Series V S R oil voltage 24 VD VD VD VD VD Power consumption Pressure specification Flow rate

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

Doc. No.SYJ300-OMV0001. Solenoid Valve PRODUCT NAME. SYJ Series MODEL/ Series

Doc. No.SYJ300-OMV0001. Solenoid Valve PRODUCT NAME. SYJ Series MODEL/ Series Doc. Solenoid Valve PRODUCT NAME SYJ Series MODEL/ Series Contents Safety Instructions ---------------------------------------------------------------------------- 2,3 Design / Selection ----------------------------------------------------------------------------

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Series VQ Rubber Seal Space-saving profile Clean space saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

Manifold Specifications

Manifold Specifications Series 00 Manifold Specifications Manifold Specifications Model Manifold type P(SUP)/R(EXH) Valve stations A port porting specifications Port size For internal pilot For external pilot Location Direction

More information

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series VZS Series Variations Plug-in Type Base Mounted Type (With sub-plate) Non Plug-in Type Base Mounted Type (With sub-plate) Series Sonic conductance

More information

5 Port Solenoid Valve Plug Lead Type

5 Port Solenoid Valve Plug Lead Type 5 Port Solenoid alve Plug Lead Type Series Body Ported Flow rate characteristics For single/double solenoid C [dm 3 /(s bar)]: 0.6 Single Unit alve width: 7.4 mm Possible to drive cylinders: Up to ø32

More information

Plug Lead Unit: Flip Type

Plug Lead Unit: Flip Type Series ody orted lug Lead Unit: Flip Type For details about certified products conforming to international standards, visit us at www.smcworld.com. 0 Series Kit/Electrical entry/cable length F kit (D-sub

More information

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) type (3 to ) Low water hammer or details, refer to page 07. Large

More information

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications Series -SQ00 Port Solenoid Valve Plug-in Unit [Option] How to Order Manifold Electrical entry F kit D-sub connector kit P kit SSQ 08 FD Kit type Flat ribbon cable connector kit J kit Flat ribbon cable

More information

Coolant Valve. Air Operated/External Pilot Solenoid

Coolant Valve. Air Operated/External Pilot Solenoid Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) lange type (3 to ) Low water hammer or details, refer to page

More information

1 1/4 (32A) to 2 (50A) added.

1 1/4 (32A) to 2 (50A) added. Coolant Valve 0.5 MPa.0 MPa.6 MPa RoHS /4 (3) to (50) added. Flow rate Cv (For 0.5 MPa specification) 3 4 5 0 0 30 Cv (kv) 40 5 million cycles or more Port size 70 6.5 (5.6) 3/8 (0), / (5).8 (0.) 3/4 (0)

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Rubber Seal Port Solenoid Valve Series Manifold Single Unit ase Mounted Manifold VV01 V100 ar base P.18 ody Ported P.10 ase Mounted P.10 VQD VKF VK VT VS Separable base ody Ported Manifold P.1 Stacking

More information

New Concept Connector Type Manifold

New Concept Connector Type Manifold New Concept Connector Type Manifold Series /000/3000/000 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration.

More information

High Pressure Coolant Valve

High Pressure Coolant Valve High Pressure Coolant Valve Series.5 MPa, 7.0 MPa Corresponding to high speed grinding and long drilling processes Coolant valve for high pressure coolant liquid (up to.5 MPa or 7.0 MPa) that is ideal

More information

Rubber Seal VP300/500/700

Rubber Seal VP300/500/700 Port Pilot Operated Poppet Rubber Seal 00/500/700 High flow capacity Cv1.0 (00), Cv. (500), Cv.0 (700) Low power consumption: 1.8W(DC) Possible to use as either selector valve or divider valve Changeable

More information

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Body Ported Base Mounted Series S000 S000 S000 S000 S000 S4000 S5000 Sonic conductance C [dm /s bar)] 4/ 5/(A/B R/R) Single Double.8.4

More information

VNA Application example. 3-port dual pressure, N.C. type SGH. Nozzle SGH. Coolant pump

VNA Application example. 3-port dual pressure, N.C. type SGH. Nozzle SGH. Coolant pump igh Pressure oolant Valve eries Pa/ orresponding to high speed grinding and long drilling processes oolant valve for high pressure coolant liquid (up to Pa/) that is ideal for lubrication, dust blowing

More information

Space Saving Vacuum Ejector/Vacuum Pump System

Space Saving Vacuum Ejector/Vacuum Pump System Space Saving acuum Ejector/acuum ump System Series Current 21.6 mm mm Width mm [Option] Weight 9 g Single unit with vacuum pressure switch and suction filter ZK2 ZR Z Z ZM ZL -X267 ZU Ejector.2 ump System.118

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR2 JIS Symbol type

More information