Space Saving Vacuum Ejector/Vacuum Pump System

Size: px
Start display at page:

Download "Space Saving Vacuum Ejector/Vacuum Pump System"

Transcription

1 Space Saving acuum Ejector/acuum ump System Series Current 21.6 mm mm Width mm [Option] Weight 9 g Single unit with vacuum pressure switch and suction filter ZK2 ZR Z Z ZM ZL -X267 ZU Ejector.2 ump System.118 QD- Easy-to-use vacuum pressure switch ush button type provides easy operation. acuum pressure switch with LED display NN open collector 1 output + analog voltage N open collector 1 output + analog voltage NN open collector 2 outputs N open collector 2 outputs With One-touch fittings Can copy to up to switches simultaneously. The settings of the master pressure switch (source of copy) can be copied to the slave pressure switches. Reduction in setting work revention of mistakes in setting Copy Master pressure switch (source of copy) Slave pressure switch 1 switch 2 switches switches 1

2 Space Saving acuum Ejector Series [Option] Note) CE-compliant: For DC only. How to Order Ejector Unit For Made to Order, refer to pages 11 and U K1 L E G 3 3 q w e r t y u i o!0!1!2!3!4! q Nozzle nominal size 0 07 ø0. ø0.7 ø1.0 w Exhaust type 1U 3M With silencer for single unit With silencer for manifold e Solenoid valve combination (Refer to Table (1).) r ilot valve (Refer to Table (1).) t Solenoid valve rated voltage (Refer to Table (1).) Symbol K1 Note 1) K2 J1 Note 1) J2 Q1 Q2 N1 N2 Normally closed Normally open Normally closed Normally open Latching positive common Latching positive common Latching negative common Latching negative common acuum release valve Normally closed Normally closed None None Normally closed None Normally closed None Note 1) When using K2 or J2 (supply valve normally open), ensure that the energizing time does not become longer than the non-energizing time. If the energizing time becomes longer or if the valve is energized for minutes or longer, select the DC low wattage type in Made to Order. (Refer to page 116.) Y Note 2) Standard (DC: 1 W) Note 2) DC low wattage type (0. W) Note 2) void energizing the solenoid valve for long periods of time. (Refer to Design and Selection on Specific roduct recautions.) Note 3) Note 3) Note 3) Note 3) CE-compliant 0 C (0/60 Hz) 200 C (0/60 Hz) 1 C (0/60 Hz) 220 C (0/60 Hz) 24 DC 12 DC Note 3) CE-compliant products are not available for 1, 2, 3 and 4. Table (1) Combination of Solenoid alve, ilot alve and ower Supply oltage Solenoid valve Combination ilot valve pplicable power supply voltage () combination no. symbol symbol 0 C 200 C 1 C 220 C 24 DC 12 DC q K1 w K1 Y e K2 r J1 t J1 Y y J2 u Q1 i Q2 o N1!0 N2 Combinations q to!0 in the above table are the only possible options. 2

3 Space Saving acuum Ejector Series y Electrical entry u Manual override Note 4) L LO G L-type plug connector, with 0.3 m lead wire, with light/surge voltage suppressor L-type plug connector, without connector, with light/surge voltage suppressor Grommet, with 0.3 m lead wire (Latching/C type: Not applicable) i acuum pressure switch suction filter Note ) Non-locking push type Latching type: ush-locking type Locking type (Q1/Q2/N1/N2: Not applicable) Note 4) Latching type supply valve: vailable in only. In this case, the supply valve and release valve come with a push-locking type. E 0 to 1 ka/nn open collector 2 outputs, with suction filter E 0 to 1 ka/n open collector 2 outputs, with suction filter 0 to 1 ka/nn open collector 1 output + analog voltage, with suction filter 0 to 1 ka/n open collector 1 output + analog voltage, with suction filter F 0 to 0 ka/nn open collector 2 outputs, with suction filter F 0 to 0 ka/n open collector 2 outputs, with suction filter FC 0 to 0 ka/nn open collector 1 output + analog voltage, with suction filter 0 to 0 ka/n open collector 1 output + analog voltage, with suction filter F only Note ) The filter included in this product is of an simple type, and will become clogged quickly in environments with high quantities of dust or particulates. lease make additional use of an air suction filter of the ZF, ZF or ZFC series. Warning The filter case of this suction filter is made of nylon. Contact with alcohol or similar chemicals may cause it to be damaged. lso, do not use the filter when these chemicals are present in the atmosphere. o acuum pressure switch unit specifications M!0 acuum pressure switch lead wire specifications G With unit switching function Note 6) Fixed SI unit Note 7) With unit switching function Note 6) (Initial value psi) Note 6) Under the New Measurement Law, sales of switches with the unit switching function are not allowed for use in Japan. Note 7) Fixed unit: ka Without connector Lead wire with connector (Lead wire length 2 m) With connector cover ZK2 ZR Z Z ZM ZL -X267 ZU QD-!1Check valve Note 8) Note 9)!2 Fitting ( port) Note ) None K With check valve Note 8) The check valve has a function to prevent the exhaust air from the silencer overflowing to the vacuum port side when a manifold is used, but it cannot prevent overflow of the exhaust air completely. During usage, please inspect thoroughly with actual machine. lso, in order to completely prevent the overflow of exhaust air, leave plenty of space between the check valve unit and adjacent ejector to avoid interference from the ejector s exhaust unit. Note 9) Only applicable to the exhaust type 3M and cannot be selected for solenoid valve combinations of J1, J2, Q2 and N2. Warning q Cannot be used for vacuum retention. w Use a release valve. (Without a release valve, a workpiece may not be released.) Symbol !3 Fitting ( port) pplicable tubing O.D. Without fitting (M x 0.8) ø3.2 (Straight) ø4 (Straight) ø6 (Straight) ø3.2 (Elbow) ø4 (Elbow) Note ) Symbol pplicable tubing O.D. Object spec. Without port Manifold 0 Without fitting (M x 0.8) 2 ø4 (Straight) Single unit 3 ø6 (Straight) ø4 (Elbow)!4 racket N With bracket Without bracket! CE-compliant Q CE-compliant Note) CE-compliant: For DC only. Note 11) Note ) For filter only (Without vacuum pressure switch) Single unit: When neither port fitting nor port fitting are needed, enter nothing or 00 in the dotted line How to Order. Manifold specifications: When the port fitting is not needed, enter nothing or 0 in the dotted line How to Order. Note 11) Only applicable to the exhaust type 1U. 3

4 Series How to Order Manifold Ordering Example Number of stations Note) 01 1 station 02 2 stations 08 Manifold 8 stations Z1 07 S C ir pressure supply () port position oth sides Exhaust S With silencers (oth sides) Note) Number of stations varies according to nozzle nominal size during simultaneous operation. acuum release pressure Maximum Number of Stations supply port (D port) in Simultaneous Operation None (Release pressure is Maximum number Nozzle supplied from the port.) of stations in nominal simultaneous rovided (ir can be size operation C alternatively supplied from the port.) ø0. ø0.7 ø1.0 8 stations 6 stations 4 stations Z8-S 1 pc. 3M-K1YL-EG (-Q) 4 pcs. (Stations 1 to 4) 13M-K1YL-EG (-Q) 4 pcs. (Stations to 8) Note) y viewing the front side of vacuum port (), stations are counted starting from station 1 on the left side. acuum () port 3M-K1YL-EG 13M-K1YL-EG Left Right Flow/Exhaust Characteristics / Exhaust Characteristics Maximum vacuum pressure (ka) Maximum vacuum pressure (ka) Maximum vacuum pressure (ka) Maximum vacuum pressure Supply pressure (Ma) Maximum vacuum pressure Supply pressure (Ma) Supply pressure (Ma) / Exhaust Characteristics Maximum vacuum pressure ir consumption ir consumption Maximum suction flow 7 / Exhaust Characteristics 4 ir consumption Maximum suction flow Maximum suction flow Maximum suction flow (L/min(NR)) ir consumption (L/min(NR)) Maximum suction flow (L/min(NR)) ir consumption (L/min(NR)) Maximum suction flow (L/min(NR)) ir consumption (L/min(NR)) Supply pressure / Flow Rate Characteristics 0.3 Ma Maximum vacuum pressure (ka) Suction flow (L/min(NR)) Supply pressure 7 / Flow Rate Characteristics 0.43 Ma Maximum vacuum pressure (ka) Supply pressure 0.43 Ma 1 / Flow Rate Characteristics Maximum vacuum pressure (ka) Suction flow (L/min(NR)) Suction flow (L/min(NR)) How to Read Flow Rate Characteristics acuum pressure max 1 Q1 Suction flow Qmax Flow rate characteristics are expressed in ejector vacuum pressure and suction flow. If suction flow rate changes, a change in vacuum pressure will also be expressed. Normally this relationship is expressed in ejector standard use. In the graph, max is max. vacuum pressure and Qmax is max. suction flow. The valves are specified according to catalog use. Changes in vacuum pressure are expressed in the below order. 1. When ejector suction port is covered and made airtight, suction flow becomes 0 and vacuum pressure is at maximum value (max). 2. When suction port is opened gradually, air can flow through, (air leakage), suction flow increases, but vacuum pressure decreases. (condition 1 and Q1) 3. When suction port is opened further, suction flow moves to maximum value (Qmax), but vacuum pressure is near 0. (atmospheric pressure). When vacuum port (vacuum piping) has no leakage, vacuum pressure becomes maximum, and vacuum pressure decreases as leakage increases. When leakage value is the same as max. suction flow, vacuum pressure is near 0. When ventirative or leaky work must be adsorbed, please note that vacuum pressure will not be high. recautions e sure to read this before handling the products. Refer to back page 0 for Safety Instructions and pages 49 to 1 for acuum Equipment recautions. Caution Refer to the vacuum equipment model selection on pages 2 to 48 for the selecting and sizing of series.

5 Space Saving acuum Ejector Series Specifications Ejector Nozzle nominal diameter (mm) Maximum suction flow (L/min (NR)) ir consumption (L/min (NR)) Maximum vacuum pressure ir pressure supply port () Supply pressure range Note) Maximum suction flow can be obtained by standard supply pressure. Weight Single unit Model Supply pressure Note) Supply pressure port for vacuum release (D) Operating temperature range Fluid Note 1) With suction filter 9 With vacuum pressure switch and suction filter Note 2) End plate assembly for manifold g 9 g 122 g Note 1) Including a 0.3 m connector for supply valve and vacuum release valve. Note 2) Including a 0.3 m connector for supply valve and vacuum release valve and a 2 m connector for vacuum pressure switch. Calculation of weight for the manifold type (Single unit weight) x (Number of stations) + (Weight of end plate assembly for manifold) Example) acuum pressure switch + 8 stations with suction filter 9 g x g = 994 g 0. Supply alve / acuum Release alve ka 0.3 to 0. Ma (Normally open: 0.3 to 0.4 Ma) 0.3 to 0. Ma (Normally open: 0.3 to 0.4 Ma), and also D pressure pressure 0.3 Ma 0.43 Ma to 0 C ir Normally closed Type Standard (1 W) Low wattage type (0. W) Latching type Normally open Model Refer to How to Order for Q1- Q1Y- Q1 ( solenoid valves on page 7. ) L - 1-Q120- Manual override Non-locking push type / Locking type (Tool type) ush-locking type Non-locking push type / Locking type (Tool type) Rated coil voltage 12, 24 DC, 0, 1, 200, 220 C 12, 24 DC 12, 24 DC, 0, 1, 200, 220 C 12, 24 DC DC 1 W 0. W 1 W ower consumption (current value) 0 C 1 C 200 C 220 C 0. ( m) 0. ( m) 1.0 ( m) 1.1 ( m) 0.6 (6 m) 0.6 (.9 m) 1.2 (6 m) 1.3 (.9 m) Electrical entry Grommet L-type plug connector Grommet L-type plug connector L-type plug connector with light/surge with light/surge (with light/surge voltage suppressor) ( voltage suppressor ) ( voltage suppressor ) ZK2 ZR Z Z ZM ZL -X267 ZU QD-

6 Series Specifications acuum ressure Switch Model 1-ZSE (ZSE) 1-ZSF (ZSEF) Rated pressure range Set pressure range/display pressure range 0 to 1 ka to ka 0 to 0 ka to ka Withstand pressure Minimum setting unit ower supply voltage Current consumption Switch output Maximum load current Maximum applied voltage Residual voltage Response time Short circuit protection Repeatability 00 ka 0.1 ka 12 to 24 DC ±%, Ripple (p-p) % or less (with power supply polarity protection) 40 m or less NN or N open collector: 2 outputs (selectable) 80 m 28 (with NN output) 2 or less (with load current of 80 m) 2. ms or less (Response time selections with anti-chattering function: 20, 0, 00, 00 and 2000 ms) With short-circuit protection ±0.2% F.S. ±1 digit Hysteresis mode Hysteresis ariable (0 or above) Note 1) Window comparator mode Display system Display accuracy Operation indicator light Enclosure nalog oltage output output Output voltage (rated pressure range) Linearity Output impedance 1 to ±2.% F.S. ±1% F.S. or less pprox. 1 kω 3 1/2-digit, 7 segment LED 1-color display (Red) ±2% F.S. ±1 digit (at ambient temperature of 2 ±3 C) Lights when ON, OUT1: Green, OUT2: Red I40 mbient humidity range Operating/Stored: 3 to 8% RH (with no condensation) Environmental Withstand voltage 00 C for 1 min. between terminals and housing resistance Insulation resistance 0 MΩ or more (00 DC measured via megohmmeter) between terminals and housing ibration resistance Impact resistance Temperature characteristics Lead wires to Hz at the smaller of amplitude 1. mm or acceleration 20 m/s 2 in X, Y, Z directions for 2 hrs. each (De-energized) 0 m/s 2 in X, Y, Z directions 3 times each (De-energized) ±2% F.S. (at 2 C of ambient temperature range between and 0 C) Oil-resistant cabtire cord Cross section: 0.1 mm 2 (WG26), cores, 2 m, Conductor O.D.: 1.0 mm Note 1) If the applied voltage fluctuates around the set-value, the hysteresis must be set to a value more than the fluctuating width, otherwise chattering will occur. Note 2) For others, refer to ejector specifications on page. Construction Single unit Manifold t e r y!0 w u q i o Component arts No. Description Material oppet valve assembly Nozzle Diffuser acuum release flow adjustment needle Resin Resin Stainless steel 6 Replacement arts No. Description Material art no. Solenoid valve Refer to page 7. 6 Filter element sponge XT S 7 Sound absorbing material 1 (single unit) sponge -SE 8 9 acuum pressure switch Fitting Refer to page 7. Sound absorbing material 2 (manifold) sponge Z-SE

7 Space Saving acuum Ejector Series Solenoid alve ctuation 1 Normally closed Q Q1 2 0 ctuation 2 Normally open ilot valve Standard (1 W) Solenoid valve rated voltage 24 DC 6 12 DC How to Order ilot valve Standard (DC: 1 W) Low wattage type (0. W) Y C type: Not applicable L Latching positive common N Latching negative common L L Connector assembly part no. Solenoid valve rated voltage 1 0 C (0/60 Hz) C (0/60 Hz) 3 1 C (0/60 Hz) C (0/60 Hz) 24 DC 6 12 DC Manual override Note) Non-locking push type Latching type: ush-locking type Locking type Note) Latching type: vailable in only acuum ressure Switch 1-ZS acuum pressure switch specifications E E F F FC 0 to 1 ka/nn open collector 2 outputs, with suction filter 0 to 1 ka/n open collector 2 outputs, with suction filter 0 to 1 ka/nn open collector 1 output + analog voltage, with suction filter 0 to 1 ka/n open collector 1 output + analog voltage, with suction filter 0 to 0 ka/nn open collector 2 outputs, with suction filter 0 to 0 ka/n open collector 2 outputs, with suction filter 0 to 0 ka/nn open collector 1 output + analog voltage, with suction filter 0 to 0 ka/n open collector 1 output + analog voltage, with suction filter acuum pressure switch unit specifications M With unit switching function Note 1) Fixed SI unit Note 2) acuum pressure switch With unit switching function Note 1) lead wire specifications (Initial value psi) Note 1) Under the New Measurement Law, sales of switches with the unit switching function are not allowed for use in Japan. Note 2) Fixed unit: ka How to order connector assembly Single XT DC positive common Latching XT DC negative common Latching XT661-13N- 0 C Single XT Latching XT C Single XT Latching XT Lead wire length mm 600 mm 00 mm 2000 mm 3000 mm Connector, socket (3 pcs) only XT Lead wire length of the plug connector The lead wire length for a valve with a lead wire is 300 mm. When in need of a valve with a lead wire longer than 600 mm, place an order for a valve without a connector and connector assembly. The vacuum pressure switch mounted on this product is equivalent to our product, the ZSE series compact digital pressure switch. ressure switch acuum Ejector series 1 For details regarding vacuum pressure correspondence switches, refer to the ZSE series in table acuum ressure Switch for 1 ZS the est neumatics No.8. Digital ressure Switch ZSE series ZSE acuum pressure switch for 1-ZSE-- 1-ZSE-- 1-ZS-- 1-ZS-- 1-ZSF-- 1-ZSF-- 1-ZSFC-- 1-ZS-- G ZSE series ZSE--- ZSE--- ZSE--C- ZSE--E- ZSEF--- ZSEF--- ZSEF--C- ZSEF--E- Electrical entry Note) L-type plug connector, L with 0.3 m lead wire L-type plug connector, LO without connector Grommet, with 0.3 m lead wire G (Latching/C type: Not applicable) Note) Mounting screws are attached. Without connector Lead wire with connector (lead wire length 2 m) With connector cover Rated pressure range/output specifications (Refer to rated pressure range/output specifications correspondence table) Rated pressure range/output specifications correspondence table Check valve K Note 3) None With check valve Note 3) The check valve has a function to prevent the exhaust air from the silencer overflowing to the vacuum port side when a manifold is used, but it is incapable of completely preventing overflow. During usage, please inspect thoroughly with actual machine. lso, in order to completely prevent the overflow of exhaust air, leave plenty of space between the check valve unit and adjacent ejector to avoid interference from the ejector s exhaust unit. Warning q Cannot be used for vacuum retention. w Use a vacuum release valve. (Without a vacuum release valve, the workpiece may not be released.) Lead wire with connector part no. ZS-39-G Note Lead wire length 2 m (With connector cover) Specification 0 to 1 ka/nn open collector 2 outputs 0 to 1 ka/n open collector 2 outputs 0 to 1 ka/nn open collector 1 output + analog voltage 0 to 1 ka/n open collector 1 output + analog voltage 0 to 0 ka/nn open collector 2 outputs 0 to 0 ka/n open collector 2 outputs 0 to 0 ka/nn open collector 1 output + analog voltage 0 to 0 ka/n open collector 1 output + analog voltage Fitting ( port) Symbol pplicable tubing O.D. 0 Without fitting (M x 0.8) 1 ø3.2 (Straight) 2 ø4 (Straight) 3 ø6 (Straight) 4 ø3.2 (Elbow) ø4 (Elbow) acuum pressure switch lead wire specification acuum pressure switch unit specification 7 ZK2 ZR Z Z ZM ZL -X267 ZU QD-

8 Series Type K1 1 1U-K x ø3. Mounting hole acuum release flow adjusting needle ilot pressure exhaust (E) port M3, tmospheric release Note 4) ir pressure supply () port M Note 4) Circuit diagram E 1 E (300) (49.) E E 1U-K1 6- F - F (Grommet type) - Type J1 1 1U-J1 - - EXH FC (With L-type plug connector) x ø3.2 through (ody mounting hole) (63.1) F - E E F F K - FC racket (Standard) Release valve K - 7. Note 1) Exhaust part F K- acuum pressure switch (3.7) acuum () port (M) Note 4) 8.4 Note 1) The above dimensions are for 1 1U-K1 L-E G -00. In case of 1 1U-K1 6 -F -00, the overall length is Note 2) marked with are those after bracket is mounted. Note 3) When the body is mounted, tighten with a torque of 0.6 ± 0.06 N m. Using excessive torque may cause damage to the body. Note 4) The pitches of, and E ports are determined assuming the use of One-touch fittings. If used with other fittings, these may cause interference, dependant on their type and size. lease refer to the catalog to confirm the sizes of the fittings to be used. 6 ilot pressure exhaust (E) port M3, tmospheric release Note 4) ir pressure supply () port M Note 4) E 0.8 (63.1) 3. (C type) (With L-type plug connector) x ø3.2 through (ody mounting hole) (63.1) racket (Standard) Exhaust part 7. Note 1) acuum pressure switch (3.7) acuum () port (M) Note 4) 8.4 Circuit diagram 8 E E F 1 1U-J1- E - F EXH EF FC - F - Note 1) The above dimensions are for 1 1U-J1 6L-E G -00. In case of 1 1U-J1 -F -00, the overall length is Note 2) The dimensions after bracket is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0.6 ± 0.06 N m. Using excessive torque may cause damage to the body. Note 4) The pitches of, and E ports are determined assuming the use of One-touch fittings. If used with other fittings, these may cause interference, dependant on their type and size. lease refer to the catalog to confirm the sizes of the fittings to be used.

9 Space Saving acuum Ejector Series Type K2 1 1U-K2 - - acuum release flow adjusting needle Circuit diagram E 1 ilot exhaust port (E port) M3, tmospheric release Note 4) ir pressure supply () port M Note 4) 1U-K F - E E F F E EXH FC (With L-type plug connector) 2 x ø3.2 through (ody mounting hole Note 2) ) (68.4) E E F F K - racket (Standard) Note 1) FCK - Release valve Exhaust part 68.3 Note 1) The above dimensions are for 1 1U-K2 6 L-F -. In case of 1 1U-K2 - E -, the overall length is 7.. F Note 2) The dimensions after bracket is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0.6 ± 0.06 N m. Using excessive torque may cause damage to the body. Note 4) The pitches of, and E ports are determined assuming the use of One-touch fittings. If used with other fittings, these may F K- cause interference, dependant on their type and size. lease refer to the catalog to confirm the sizes of the fittings to be used. acuum () port (M) Note 4) 9.7 ZK2 ZR Z Z ZM ZL -X267 ZU QD- Type J2 1 1U-J2 - - (With L-type plug connector) racket (Standard) ilot exhaust port (E port) M3, tmospheric release Note 4) ir pressure supply () port M Note 4) (68.4) 2 x ø3.2 through (ody mounting hole Note 2) ) E Exhaust part acuum () port (M) Note 4) Note 1) Circuit diagram E 1 EXH E E 1U-J26 - F - F - F FC - Note 1) The above dimensions are for 1 1U-J2 6 L-F. In case of 1 1U-J2 - E F -, the overall length is 7.. Note 2) The dimensions after bracket is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0.6 ± 0.06 N m. Using excessive torque may cause damage to the body. Note 4) The pitches of, and E ports are determined assuming the use of One-touch fittings. If used with other fittings, these may cause interference, dependant on their type and size. lease refer to the catalog to confirm the sizes of the fittings to be used. 9

10 0 0 0 Series Type Q1, N1 1 1U-Q U-N acuum release flow adjusting needle ilot pressure exhaust (E) port M3, tmospheric release Note 4) ir pressure supply () port M Note 4) E 0.8 (63.1) x ø3.2 through (ody mounting hole) racket (Standard) Release valve 7. Note 1) Exhaust part acuum pressure switch (3.7) acuum () port (M) Note 4) 8.4 Circuit diagram E Q 1 1U- N1 6 - E E F F - Type Q2, N2 1 1U-Q U-N EXH FC - F - E E F F K - FC K - Q Note 1) The above dimensions are for 1 1U- N1 6 L-E G -00. Q In case of 1 1U- N1 6 -F -00, the overall length is Note 2) The dimensions after bracket is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0.6 ± 0.06 N m. Using excessive torque may cause damage to the body. Note 4) The pitches of, and E ports are determined assuming the use of One-touch fittings. If used with F K- other fittings, these may cause interference, dependant on their type and size. lease refer to the catalog to confirm the sizes of the fittings to be used. ilot pressure exhaust (E) port M3, tmospheric release Note 4) ir pressure supply () port M Note 4) E 0.8 (63.1) 2 x ø3.2 through (ody mounting hole) racket (Standard) 62.8 Exhaust part 7. Note 1) acuum pressure switch (3.7) acuum () port (M) Note 4) 8.4 Circuit diagram E 1 1 Q 1U- N2- E E F F EXH - FC - F - Note 1) The above dimensions are for 1 Q 1U- N2 6L-E G -00. In case of 1 Q 1U- N2 6 -F -00, the overall length is Note 2) The dimensions after bracket is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0.6 ± 0.06 N m. Using excessive torque may cause damage to the body. Note 4) The pitches of, and E ports are determined assuming the use of One-touch fittings. If used with other fittings, these may cause interference, dependant on their type and size. lease refer to the catalog to confirm the sizes of the fittings to be used.

11 0 0 Space Saving acuum Ejector Series Manifold type (without D port) Z1 -S 1 3M (ody mounting hole Note 4) ) Section 3. L2 L1 13 (itch) = Note 2) 63.6 (With L-type plug connector) (60.1) ttached washer (R) 2 x ø3. (ody mounting 13.2 hole Note 4) ) E E Common pilot pressure exhaust (E) port (One-touch fitting: pplicable tubing O.D. ø4), tmospheric release Common air pressure supply () port (One-touch fitting: pplicable tubing O.D. ø8) Release valve acuum pressure switch acuum release flow adjusting needle Exhaust part 76.8 ttached washer ZK2 ZR Z Z ZM ZL -X267 ZU QD Note 1) 111 Note 1) (mm) n L L Circuit diagram EXH E 9 8. Note 1) The above dimensions are for Z4-S. 1 3M-K1 L-E G M-K2 6L-E GK M-J1 L-F M-Q1 6L-E -0. In case of 1 3M- K J -F -0, the overall length is In case of 1 3M- Q N -F -0, the overall length is In case of 1 3M- K - E J F -0, the overall length is 7.. In case of 1 3M- Q N - E F -0, the overall length is 111. (3.7) Left 21 K E Note 2) The above dimensions are for 1 3M- J F -. Right acuum () port (M) Note ) Note 3) marked with are those after the attached square bracket is mounted. Note 4) When the body is mounted, tighten with a torque of 0.6 ± 0.06 N m. Using excessive torque may cause damage to the body. Note ) The pitches of ports are determined assuming the use of One-touch fittings. If used with other fittings, these may cause interference, dependant on their type and size. lease refer to the catalog to confirm the sizes of the fittings to be used. Note 6) When the release valve is not used, design the circuit for vacuum release separately in order to release a workpiece. EXH E 1 3M-K1 6- E E F - F 1 3M-K26- FCK - 1 3M-J1 -F- 1 3M-Q16 - FK- 111

12 0 0 Series Manifold type (with D port) Z1 -SC 1 3M- - - Common pilot pressure exhaust (E) port (One-touch fitting: pplicable tubing O.D. ø4) tmospheric release. Common air pressure supply () port (One-touch fitting: pplicable tubing O.D. ø8) Release valve Common release pressure supply (D) port (One-touch fitting: pplicable tubing O.D. ø4) L2 L1 13 (itch) = 8 4 x M through (for mounting) acuum release flow adjusting needle Exhaust part acuum pressure switch Note 2) (mm) n L1 L Note 1) The above dimensions are for Z4-SC. 1 3M-K1 L-E G M-K2 6L-E G M-J1 L-F M-Q1 6 L-E G-0. In case of 1 3M- -F -0, the overall length is In case of 1 3M- -E G-0, the overall length is (3.7) Left 21 Right acuum () port (M) Note 4) K Note 2) The above dimensions are for 1 3M- J Note 3) When the body is mounted, tighten with a torque of 0.6 ± 0.06 N m. Using excessive torque may cause damage to the body. Note 4) The pitches of ports are determined assuming the use of One-touch fittings. If used with other fittings, these may cause interference, dependant on their type and size. lease refer to the catalog to confirm the sizes of the fittings to be used. Note ) When the release valve is not used, design the circuit for vacuum release separately in order to release a workpiece. Circuit diagram EXH E D E D EXH 1 3M-K1 6- E E F - F 1 3M-K26- FCK - 1 3M-J1 -F- 1 3M-Q16- FK- 112

13 Space Saving acuum Ejector Series Fittings / Fitting type filter dimensions after installation port <With vacuum pressure switch> pplicable thread size: M acuum () port (3.7) port < only> KQ2S23-MN1 Q00-0-M 14. KQ2L23-MN1 ø ø7 1.3 ø6.7 ø7.9 ø pplicable tubing O.D.: ø3.2 acuum () port pplicable tubing O.D.: ø3.2 acuum () port pplicable tubing O.D.: ø4 acuum () port pplicable tubing O.D.: ø4 acuum () port pplicable tubing O.D.: ø6 acuum () port Q00-0-C3 Q00-0-C4 Q00-0-C Q00-F1-LC KQ2L04-MN1 KQ2S04-MN ø ø ø7.9 ø 9.2 Q00-F1-LC KQ2S06-MN ZK2 ZR Z Z ZM ZL -X267 ZU QD- port 7.7 ø8 KQ2S04-MN1 KQ2S06-MN ø KQ2L04-MN1 113

14 Series Manifold Exploded iew e y b r y y r y No a) part t Component arts Description a) part Hexagon socket head cap screw End block L End block R 4 Ejector assembly Ejector body gasket for manifold 6 Exhaust block gasket t a) part t art no. Refer to How to Order below. Refer to Table (1) (including 1 pc. of y). Refer to Table (1) (including 1 pc. of t). Note 1) Refer to pages 2 and 3 for detailed description of How to Order. Note 2) pcs. are included in one set. w Table (1) Note 1) 13M--- (-Q) (1 pc. each in t and y is included.) Description Note 2) S End block L Note 2) S End block R q b) view With D port 1L-2-S-S 1R-2-S-S Without D port 1L-1-S-S 1R-1-S-S Working rocedure Disassembly Loosen and remove the clamp rod q. ssembly 1. Install the ejector body gasket for manifold t into the gasket groove of each ejector assembly r. Install the exhaust block gasket y around the projected part. 2. Install the exhaust block gasket y around the projected part of the end block L w. 3. Install the ejector body gasket for manifold t into the gasket groove of the end block R e. 4. lign the ejector assemblies r, end block (L) w, and end block (R) e using positioning pins (at the two a positions) and fasten with clamp rods q (2 pcs.) (with a tightening torque of 0.6 N m ± 0.06 N m). Replacement of ort Fittings (With vacuum pressure switch) port fittings are cassette style for easy replacement. The fittings are blocked by a clip. Remove the clip with a flat blade screwdriver, etc. to replace the fittings. When mounting the fittings, after inserting the fitting assembly until it stops, then put the clip into the prescribed position completely. How to Order Hexagon Socket Head Cap Screw ST 0 Note) 2 pcs. are included in one set. Number of stations 01 1 station 02 2 stations 08 8 stations pplicable tubing O.D. pplicable tubing O.D. ø3.2 pplicable tubing O.D. ø4 pplicable tubing O.D. ø6 M female thread Clip (ZK1-C-) pcs. in one set Straight Q00-0-C3 Q00-0-C4 Q00-0-C6 Q00-0-M Fitting assembly Elbow Q00-F1-LC3 Q00-F1-LC4 114

15 Series Made to Order Specifications lease contact for detailed dimensions, specifications and lead times. 1 ort Exhaust Specifications Manifold Z1 Stations Manifold type (without D port) Z1-2-X12 1 3M X12 Exhaust port is changed for ort Exhaust Specifications. ort exhaust specifications (-Q) 2 x Rc1/4 EXH. port ZK2 ZR Z Z ZM ZL -X267 ZU 6.8 QD

16 Series Made to Order Specifications lease contact for detailed dimensions, specifications and lead times. 2 ilot alve for Supply: Normally Open DC Low Wattage Specification ower consumption (W): 0.3 [Inrush 1., Holding 0.3] 1 3M K2 Y X18 K2 J2 Nozzle nominal size Solenoid valve combination Fitting ilot valve for supply Normally open DC low wattage specification : Normally open acuum release valve: Normally closed : Normally open acuum pressure switch suction filter acuum release valve: None Solenoid valve rated voltage 24 DC 6 12 DC Electrical entry L L-type plug G Grommet Manual override Non-locking push Locking type Normally open supply valve with low wattage type pilot valve mounted When the normally open specification is selected as a countermeasure for power failure, the temperature increase of the solenoid valve can be suppressed in the operation cycle where the vacuum suspension state (supply valve energizing) is longer than the vacuum generation state. : Same as standard type. 116

17 Space Saving acuum ump System Series [Option] Note) CE-compliant: For DC only. acuum ump Unit 00 U K1 How to Order L E G 3 3 q w e r t y u i o!0!1!2!3 q ody type U M For single unit For manifold w Solenoid valve combination (Refer to Table (1).) Symbol K1 Note 1) K2 J1 Note 1) J2 Q1 Q2 N1 N2 Normally closed Normally open Normally closed Normally open Latching positive common Latching positive common Latching negative common Latching negative common acuum release valve Normally closed Normally closed None None Normally closed None Normally closed None The air in the adsorption section of this product is not released to the atmosphere at the vacuum suspension state. s for K1, K2, Q1 and N1, use the vacuum release valve when a workpiece is detached. Concerning J1, J2, Q2 and N2, devise the circuit for the vacuum release additionally when a workpiece is detached. Note 1) In cases when K2 or J2 (supply valve normally open) is selected for the solenoid valve combination, when vacuum is stopped for long periods of time ( minutes or more), do not continue to energize the supply valve, and shut off the air supply. e ilot valve (Refer to Table (1).) Y Note 2) Standard (DC: 1 W) Note 2) DC low wattage type (0. W) Note 2) void energizing the solenoid valve for long periods of time. (Refer to Specific roduct recautions 1; Caution on Design and Selection.) r Solenoid valve rated voltage (Refer to Table (1).) Note 3) Note 3) Note 3) Note 3) CE-compliant 0 C (0/60 Hz) 200 C (0/60 Hz) 1 C (0/60 Hz) 220 C (0/60 Hz) 24 DC 12 DC Note 3) CE-compliant products are not available for 1, 2, 3 and 4. Table (1) Combination of Solenoid alve, ilot alve and Rated oltage Solenoid valve Combination combination ilot valve pplicable power supply voltage () no. symbol symbol 0 C 200 C 1 C 220 C 24 DC 12 DC q w e r t y u i o!0 K1 K1 K2 J1 J1 J2 Q1 Q2 N1 N2 Y Y Combinations q to!0 in the above table are the only possible options. 118

18 Space Saving acuum ump System Series t Electrical entry y Manual override Note 4) L LO G L-type plug connector, with 0.3 m lead wire, with light/surge voltage suppressor L-type plug connector, without connector, with light/surge voltage suppressor Grommet, with 0.3 m lead wire (Latching/C type: Not applicable) u acuum pressure switch suction filter Note ) Non-locking push type Latching type: ush-locking type Locking type (Q1/Q2/N1/N2: Not applicable) Note 4) Latching type supply valve: vailable in only. In this case, the supply valve and release valve come with a push-locking type. E 0 to 1 ka/nn open collector 2 outputs, with suction filter E 0 to 1 ka/n open collector 2 outputs, with suction filter 0 to 1 ka/nn open collector 1 output + analog voltage, with suction filter 0 to 1 ka/n open collector 1 output + analog voltage, with suction filter F 0 to 0 ka/nn open collector 2 outputs, with suction filter F 0 to 0 ka/n open collector 2 outputs, with suction filter FC 0 to 0 ka/nn open collector 1 output + analog voltage, with suction filter 0 to 0 ka/n open collector 1 output + analog voltage, with suction filter F only Note ) The filter included in this product is of an simple type, and will become clogged quickly in environments with high quantities of dust or particulates. lease make additional use of an air suction filter of the ZF, ZF or ZFC series. Warning The filter case of this suction filter is made of nylon. Contact with alcohol or similar chemicals may cause it to be damaged. lso, do not use the filter when these chemicals are present in the atmosphere. i acuum pressure switch unit specifications M o acuum pressure switch lead wire specifications G With unit switching function Note 6) Fixed SI unit Note 7) With unit switching function Note 6) (Initial value psi) Note 6) Under the New Measurement Law, sales of switches with the unit switching function are not allowed for use in Japan. Note 7) Fixed unit: ka Without connector Lead wire with connector (Lead wire length 2 m) With connector cover ZK2 ZR Z Z ZM ZL -X267 ZU QD-!0 Fitting ( port) Note 8) Note 8)!1 Fitting (S / port) Symbol pplicable tubing O.D. Without fitting (M x 0.8) ø3.2 (Straight) ø4 (Straight) ø6 (Straight) ø3.2 (Elbow) ø4 (Elbow) Symbol pplicable tubing O.D. Without port Without fitting (M x 0.8) ø4 (Straight) ø6 (Straight) ø4 (Elbow) Object spec. Manifold Single unit!2 racket N With bracket Without bracket Note 9) Note 8) For filter only (Without vacuum pressure switch) Single unit: When neither port fitting nor S/ port fitting are needed, enter nothing or 00 in the dotted line How to Order. Manifold specifications: When the port fitting is not needed, enter nothing or -0 in the dotted line How to Order. Note 9) Only applicable to the body type U.!3 CE-compliant Q CE-compliant Note) CE-compliant: For DC only. 119

19 Series How to Order Manifold Ordering Example Manifold Number of stations 01 1 station 02 2 stations 08 8 stations 08 acuum pressure supply port ( port) ort location (Refer to Table (1).) L Left side R Right side O Table (1) ir ressure Supply ort Location on the Manifold Manifold D port ort location C L (Left side) R (Right side) L (Left side) R (Right side) S Note) Left D S Note) Right D Note) The position of each port is shown as right and left sides viewed from the front side of the vacuum port. Release pressure is commonly supplied from the S port. S: ilot presure supply port, : acuum pressure supply port, D: Release pressure supply port 67Z8-RO 1 pc. 213M-K1YL-EG134 00M-K1L-EG (-Q) 4 pcs. (Stations 1 to 4) 8Z1 00M-K1YL-EG (-Q) 4 pcs. (Stations to 8) Note) y viewing the front side of vacuum port (), stations are counted starting from station 1 on the left side. Left Right 3M-K1YL-EG acuum port C Release pressure supply port (D port) None (Release pressure is supplied from the S port.) rovided (ir can be alternatively supplied from the S port.) Specifications Common Switching method for vacuum/release valve Cv factor acuum pressure supply port () Supply pressure range ilot/ressure port (S) Supply pressure port for vacuum release (D) Operating temperature range Fluid Supply alve / acuum Release alve Electrical entry iloted to 1.3 ka 0.3 to 0. Ma (Normally open: 0.3 to 0.4 Ma) 0.3 to 0. Ma (Normally open: 0.3 to 0.4 Ma), and also D pressure S pressure to 0 C ir Grommet L plug connector L-type plug connector (with light/surge voltage suppressor) Weight Single unit Note 1) With suction filter With vacuum pressure switch and suction filter Note 2) End plate assembly for manifold 9 g 9 g 122 g Note 1) Including a 0.3 m connector for supply valve and vacuum release valve. Note 2) Including a 0.3 m connector for supply valve and vacuum release valve and a 2 m connector for vacuum pressure switch. Calculation of weight for the manifold type (Single unit weight) x (Number of stations) + (Weight of end plate assembly for manifold) Example) acuum pressure switch + 8 stations with suction filter 9 g x g = 994 g Type Normally closed Item Standard (1 W) Low wattage type (0. W) Latching type Normally open (Refer to How to Order for Model solenoid valves on page 122.) Q1- Q1Y- L Q1 N - 1-Q120- Manual override Non-locking push type / Locking type (Tool type) ush-locking type Non-locking push type / Locking type (Tool type) Rated coil voltage 12, 24 DC, 0, 1, 200, 220 C 12, 24 DC 12, 24 DC, 0, 1, 200, 220 C 12, 24 DC DC 1 W 0. W 1 W ower consumption (current value) 0 C 1 C 200 C 0. ( m) 0. ( m) 1.0 ( m) 0.6 (6 m) 0.6 (.9 m) 1.2 (6 m) 220 C 1.1 ( m) 1.3 (.9 m) L plug connector (with light/surge voltage suppressor) Grommet Light/Surge voltage suppressor (with light/surge voltage suppressor) 120

20 Space Saving acuum ump System Series Specifications acuum ressure Switch Model Rated pressure range Set pressure range/display pressure range Withstand pressure Minimum setting unit ower supply voltage Current consumption Switch output Maximum load current Maximum applied voltage Residual voltage Response time Short circuit protection Repeatability Hysteresis mode Hysteresis Window comparator mode nalog output Display system Display accuracy Operation indicator light Environmental resistance oltage output Enclosure mbient humidity range Withstand voltage Insulation resistance Temperature characteristics Lead wires Output voltage (rated pressure range) Linearity Output impedance 1-ZSE (ZSE) 0 to 1 ka to ka 1-ZSF (ZSEF) 0 to 0 ka to ka 00 ka 0.1 ka 12 to 24 DC ±%, Ripple (p-p) % or less (with power supply polarity protection) 40 m or less NN or N open collector: 2 outputs (selectable) 80 m 28 (with NN output) 2 or less (with load current of 80 m) 2. ms or less (Response time selections with anti-chattering function: 20, 0, 00, 00 and 2000 ms) With short-circuit protection ±0.2% F.S. ±1 digit ariable (0 or above) Note 1) 1 to ±2.% F.S. ±1% F.S. or less pprox. 1 kω 3 1/2-digit, 7 segment LED 1-color display (Red) ±2% F.S. ±1 digit (at ambient temperature of 2 ±3 C) Lights when ON, OUT1: Green, OUT2: Red I40 Operating/Stored: 3 to 8% RH (with no condensation) 00 C for 1 min. between terminals and housing 0 MΩ or more (00 DC measured via megohmmeter) between terminals and housing ±2% F.S. (at 2 C of ambient temperature range between and 0 C) Oil-resistant cabtire cord Cross section: 0.1 mm 2 (WG26), cores, Conductor O.D.: 1.0 mm Note 1) If the applied voltage fluctuates around the set-value, the hysteresis must be set to a value more than the fluctuating width, otherwise chattering will occur. Note 2) For others, refer to ejector specifications on page 120. Construction u r w q e t y i Component arts No. Description 1 oppet valve assembly for supply valve 2 oppet valve assembly for vacuum release valve 3 acuum release flow adjusting needle Replacement arts No Description Solenoid valve Filter element acuum pressure switch Fitting Fitting Material sponge art no. Refer to page 122. XT S Refer to page 122. Material Stainless steel ZK2 ZR Z Z ZM ZL -X267 ZU QD- 121

21 Series Solenoid alve ctuation 1 Normally closed Q Q1 2 0 E E F F FC ctuation 2 Normally open ilot valve Standard (1 W) Solenoid valve rated voltage 24 DC 6 12 DC acuum ressure Switch How to Order ilot valve Standard (DC: 1 W) Low wattage type (0. W) Y C type: Not applicable L Latching positive common N Latching negative common L L 1-ZS acuum pressure switch specifications 0 to 1 ka/nn open collector 2 outputs, with suction filter 0 to 1 ka/n open collector 2 outputs, with suction filter 0 to 1 ka/nn open collector 1 output + analog voltage, with suction filter 0 to 1 ka/n open collector 1 output + analog voltage, with suction filter 0 to 0 ka/nn open collector 2 outputs, with suction filter 0 to 0 ka/n open collector 2 outputs, with suction filter 0 to 0 ka/nn open collector 1 output + analog voltage, with suction filter 0 to 0 ka/n open collector 1 output + analog voltage, with suction filter Note) Mounting screws are attached. Connector assembly part no. Solenoid valve rated voltage 1 0 C (0/60 Hz) C (0/60 Hz) 3 1 C (0/60 Hz) C (0/60 Hz) 24 DC 6 12 DC Manual override Note) Non-locking push type Latching type: ush-locking type Locking type Note) Latching type: vailable in only Electrical entry Note) L-type plug connector, L with 0.3 m lead wire L-type plug connector, LO without connector Grommet, with 0.3 m lead wire G (Latching/C type: Not applicable) acuum pressure switch unit specifications With unit switching function Note 1) M Fixed SI unit Note 2) acuum pressure switch With unit switching function Note 1) lead wire specifications (Initial value psi) Without connector Note 1) Under the New Measurement Law, sales Lead wire with connector of switches with the unit switching function G (lead wire length 2 m) are not allowed for use in Japan. With connector cover Note 2) Fixed unit: ka acuum pressure switch for 1-ZSE-- 1-ZSE-- 1-ZS-- 1-ZS-- 1-ZSF-- 1-ZSF-- 1-ZSFC-- 1-ZS-- ZSE series ZSE--- ZSE--- ZSE--C- ZSE--E- ZSEF--- ZSEF--- ZSEF--C- ZSEF--E- Check valve Warning q Cannot be used for vacuum retention. w Use a vacuum release valve. (Without a vacuum release valve, the workpiece may not be released.) Lead wire with connector part no. Note Lead wire length 2 m ZS-39-G (With connector cover) Specification 0 to 1 ka/nn open collector 2 outputs 0 to 1 ka/n open collector 2 outputs 0 to 1 ka/nn open collector 1 output + analog voltage 0 to 1 ka/n open collector 1 output + analog voltage 0 to 0 ka/nn open collector 2 outputs 0 to 0 ka/n open collector 2 outputs 0 to 0 ka/nn open collector 1 output + analog voltage 0 to 0 ka/n open collector 1 output + analog voltage How to order connector assembly Single XT DC positive common Latching XT DC negative common Latching XT661-13N- 0 C Single XT Latching XT C Single XT Latching XT Connector, socket (3 pcs) only XT Lead wire length 300 mm mm 00 mm mm mm Lead wire length of the plug connector The lead wire length for a valve with a lead wire is 300 mm. When in need of a valve with a lead wire longer than 600 mm, place an order for a valve without a connector and connector assembly. The vacuum pressure switch mounted on this product is equivalent to our product, the ZSE series compact digital pressure switch. ressure switch acuum ump System series 1 For details regarding vacuum pressure correspondence switches, refer to the ZSE series in table acuum ressure Switch for 1 ZS the est neumatics No.8. Digital ressure Switch ZSE series ZSE Rated pressure range/output specifications (Refer to rated pressure range/output specifications correspondence table) acuum pressure switch lead wire specification Rated pressure range/output specifications correspondence table acuum pressure switch unit specification K Note 3) None With check valve Note 3) The check valve has a function to prevent the exhaust air from the silencer overflowing to the vacuum port side when a manifold is used, but it is incapable of completely preventing overflow. During usage, please inspect thoroughly with actual machine. lso, in order to completely prevent the overflow of exhaust air, leave plenty of space between the check valve unit and adjacent ejector to avoid interference from the ejector s exhaust unit. Symbol Fitting ( port) pplicable tubing O.D. Without fitting (M x 0.8) ø3.2 (Straight) ø4 (Straight) ø6 (Straight) ø3.2 (Elbow) ø4 (Elbow) 122

22 E Space Saving acuum ump System Series Type K1 00U-K x ø3. Mounting hole acuum release flow adjusting needle ilot pressure exhaust (E) port M3, tmospheric release Note 4) ilot pressure supply (S) port M Note 4) acuum pressure supply () port M Note 4) Circuit diagram S E S E 00U-K1 - E 6 F - F (300) (49.) (Grommet type) FC - (With L-type plug connector) (63.1) x ø3.2 through (ody mounting hole) F racket (Standard) Release valve Exhaust part acuum pressure switch Note 1) (3.7) acuum () port (M) Note 4) Note 1) The above dimensions are for 00U-K1 6L-E G -00. In case of 00U-K1 6 -F -00, the overall length is Note 2) marked with are those after bracket is mounted. Note 3) When the body is mounted, tighten with a torque of 0.6 ± 0.06 N m. Using excessive torque may cause damage to the body. Note 4) The pitches of S,, and E ports are determined assuming the use of One-touch fittings. If used with other fittings, these may cause interference, dependant on their type and size. lease refer to the catalog to confirm the sizes of the fittings to be used. 8.4 ZK2 ZR Z Z ZM ZL -X267 ZU QD- Type J1 00U-J1 - - ilot pressure exhaust (E) port M3, tmospheric release Note 4) ir pressure supply () port M Note 4) acuum pressure supply () port M Note 4) Circuit diagram S E E S 0.8 (63.1) E E 00U-J1- F - F (C type) (With L-type plug connector) (63.1) x ø3.2 through (ody mounting hole) FC - F racket (Standard) Note 1) Exhaust part acuum pressure switch (3.7) acuum () port (M) Note 4) Note 1) The above dimensions are for 00U-J1 6L-E G-00. In case of 00U-J1 -F -00, the overall length is Note 2) The dimensions after bracket is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0.6 ± 0.06 N m. Using excessive torque may cause damage to the body. Note 4) The pitches of S,, and E ports are determined assuming the use of One-touch fittings. If used with other fittings, these may cause interference, dependant on their type and size. lease refer to the catalog to confirm the sizes of the fittings to be used. Note ) In order to release a workpiece, design the circuit for vacuum release separately

23 Series Type K2 00U-K2 - - ilot pressure exhaust (E) port M3, tmospheric release Note 4) ilot pressure supply (S) port M Note 4) acuum pressure supply () port M Note 4) 7 E S 0.8 (With L-type plug connector) (68.4) x ø3.2 through (ody mounting hole Note 2) ) racket (Standard) Note 1) Release valve acuum release flow adjusting needle 68.3 acuum () port (M) Note 4) 9.7 Circuit diagram S E 00U-K2 6- F - E E F - F FC - Note 1) The above dimensions are for 00U-J1 -F-00. E In case of 00U-K1 6 - F -00, the overall length is Note 2) The dimensions after bracket is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0.6 ± 0.06 N m. Using excessive torque may cause damage to the body. Note 4) The pitches of S, E, and ports are determined assuming the use of One-touch fittings. If used with other fittings, these may cause interference, dependant on their type and size. lease refer to the catalog to confirm the sizes of the fittings to be used. Type J2 00U-J2 - - ilot pressure exhaust (E) port M3, tmospheric release Note 4) ilot pressure supply (S) port M Note 4) acuum pressure supply () port M Note 4) Circuit diagram S E 124 E S 00U-J2 6- F E E F - F (With L-type plug connector) 2 x ø3.2 through (ody mounting hole Note 2) ) (68.4) FC racket (Standard) Note 1) acuum () port (M) Note 4) Note 1) The above dimensions are for 00U-J1 -F-00. E In case of 00U-K1 6 - F -00, the overall length is Note 2) The dimensions after bracket is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0.6 ± 0.06 N m. Using excessive torque may cause damage to the body. Note 4) The pitches of S, E, and ports are determined assuming the use of One-touch fittings. If used with other fittings, these may cause interference, dependant on their type and size. lease refer to the catalog to confirm the sizes of the fittings to be used. Note ) In order to release a workpiece, design the circuit for vacuum release separately. 9.7

Space Saving Vacuum Ejector / Vacuum Pump System

Space Saving Vacuum Ejector / Vacuum Pump System CT.US0-1'-UK Space Saving acuum jector / acuum ump System Conventional ZX 21. mm mm ZQ Series ZQ Width mm Weight 9 g Single unit with vacuum pressure switch and suction filter jector ump System NW asy-to-use

More information

Series ZQ. Compact Vacuum Ejector. One-touch fitting. Digital vacuum pressure switch With LED display. ZX ZR ZM ZH ZU ZL ZY ZQ ZF ZP ZCU AMJ Misc.

Series ZQ. Compact Vacuum Ejector. One-touch fitting. Digital vacuum pressure switch With LED display. ZX ZR ZM ZH ZU ZL ZY ZQ ZF ZP ZCU AMJ Misc. Compact acuum Ejector Series Body width mm, Weight9 g (Single unit with vacuum pressure switch and suction filter) Conventional 21.mm mm One-touch fitting ZR ZM ZH ZU ZL ZY ZF Z ZCU AMJ Misc. Digital vacuum

More information

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle. Multistage Ejector 112/212 Series Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus

More information

Compact Vacuum Ejector

Compact Vacuum Ejector Compact acuum Ejector Series ZA Total length Total width 7.9 mm 9.9 mm Total height. mm Response time 0 ms Response time for up to 0 ka Nozzle diameter: ø0.7 iping: ø/ø. x 0 mm Able to install on the moving

More information

How to Order Single Unit 25A-ZK2 A 12 N 0 N N 08. e Combination of supply valve Note 3) and release valve. Note 5) K

How to Order Single Unit 25A-ZK2 A 12 N 0 N N 08. e Combination of supply valve Note 3) and release valve. Note 5) K Vacuum Unit RoHS Series 25-ZK2 How to Order Single Unit Ejector System (with Valve) Ejector System (without Valve) 25-ZK2 12 K 5 08 25-ZK2 12 0 08 q w e r t y u i Remains blank when option is not selected.

More information

How to Order Single Unit 25A-ZK2 A 12 N 0 N N 08. e Combination of supply valve Note 3) and release valve. Note 5) K. Note 6)

How to Order Single Unit 25A-ZK2 A 12 N 0 N N 08. e Combination of supply valve Note 3) and release valve. Note 5) K. Note 6) Vacuum Unit RoHS Series 25A-ZK2 How to Order Single Unit Ejector System (with Valve) Ejector System (without Valve) 25A-ZK2 A 12 K 5 A 08 25A-ZK2 A 12 0 08 q w e r t y u i Remains blank when option is

More information

Energy saving ejector

Energy saving ejector acuum Unit ZK2 Series acuum acuum ump RoHS Energy saving ejector Digital pressure switch for vacuum with energy saving function cuts supply air when the pressure reached the desired vacuum. ir consumption

More information

Energysaving. (10 mm) 3.09 inch (78.5 mm) Silencer (Built-in)

Energysaving. (10 mm) 3.09 inch (78.5 mm) Silencer (Built-in) Compact acuum Unit Ejector/acuum Pump System Quick response Compact/ Lightweight Response time of the : 5 ms acuum response time: 28 ms (Shortened by 25%; Comparison with other SMC products) Conditions:

More information

Compact Vacuum Unit. 46 g Single unit weight. New RoHS. 17% reduced 21% Ejector/Vacuum Pump System. 10 mm mm mm.

Compact Vacuum Unit. 46 g Single unit weight. New RoHS. 17% reduced 21% Ejector/Vacuum Pump System. 10 mm mm mm. Compact acuum Unit Ejector/acuum Pump System New RoHS Quick response Compact/ Lightweight Response time of the : ms acuum response time: 8 ms (Shortened by %; Comparison with other SMC products) Conditions:

More information

Large Size Vacuum Module:

Large Size Vacuum Module: arge Size acuum Module: Ejector System/acuum ump System arge suction flow rate, suitable when used with large size pads or multiple pads. Nozzle dia. ø., ø., ø.5, ø.8, ø2. acuum module suitable for handling

More information

Compact Vacuum Unit Ejector/Vacuum Pump System. 46 g. New. 17% reduced 21% 10 mm mm mm. Series ZB. Response time of the valve: 5 ms

Compact Vacuum Unit Ejector/Vacuum Pump System. 46 g. New. 17% reduced 21% 10 mm mm mm. Series ZB. Response time of the valve: 5 ms Compact acuum Unit Ejector/acuum Pump System New RoHS Quick response Compact/ Lightweight Response time of the : ms acuum response time: 8 ms (Shortened by %; Comparison with other SMC products) Conditions:

More information

Vacuum Unit Vacuum Ejector Vacuum Pump System RoHS Energy saving ejector Air consumption % reduction More efficient eject

Vacuum Unit Vacuum Ejector Vacuum Pump System RoHS Energy saving ejector Air consumption % reduction More efficient eject acuum Unit acuum Ejector acuum ump System New RoHS Energy saving ejector Digital pressure switch for vacuum with energy saving function cuts supply air when the pressure reached the desired vacuum. Air

More information

Large Size Vacuum Module:

Large Size Vacuum Module: Large Size acuum Module: System/acuum Pump System Z Large suction flow rate, suitable when used with large size pads or multiple pads. Nozzle dia. ø1.0, ø1.3, ø1.5, ø1.8, ø2.0 acuum module suitable for

More information

Large Size Vacuum Module: Ejector System/Vacuum Pump System. Nozzle size (mm): ø1.0, ø1.3, ø1.5, ø1.8, ø2.0

Large Size Vacuum Module: Ejector System/Vacuum Pump System. Nozzle size (mm): ø1.0, ø1.3, ø1.5, ø1.8, ø2.0 Large Size acuum Module: Ejector System/acuum Pump System Nozzle size (mm): ø1.0, ø1.3, ø1.5, ø1.8, ø2.0 acuum module suitable for handling workpieces of 0.5 to 5 kg. Z MJ 13-3-1 Large Size acuum Module:

More information

Large Size Vacuum Module:

Large Size Vacuum Module: Large Size acuum Module: System/acuum Pump System Large suction flow rate, suitable when used with large size pads or multiple pads. Nozzle dia. ø1.0, ø1.3, ø1.5, ø1.8, ø2.0 acuum module suitable for handling

More information

Vacuum Equipment. Application. Series

Vacuum Equipment. Application. Series Equipment Series Application Page ejector In-line vacuum ejector Multistage ejector ejector with check valve Pad with check valve ejector for water soluble coolant removal ZH ZU ZL1/2 (Special order product)

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Settings can be copied to up to 1 slave sensors at once. The settings of the master sensor can be copied to the slave sensors. Reduced setting efforts

More information

VQ1000. How to Order Manifold. Kit type

VQ1000. How to Order Manifold. Kit type - - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

VSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter

VSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter Basic performance oriented general vacuum ejector unit Series Nozzle diameter: ø.5, ø, ø1. acuum switch and vacuum break valve, etc. are unitized, so types matching the work purpose is selectable. Features

More information

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000 D-sub Connector J Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000//000 Number of connectors: pins MIL-C-08 Conforming to JIS-X-0 --6 For details

More information

Vacuum Module. Series ZX. Ejector System/Vacuum Pump System

Vacuum Module. Series ZX. Ejector System/Vacuum Pump System Vacuum Module Series ZX Ejector System/Vacuum Pump System For electronic components and precision components up to 0 g Modular design Customized application function through selection of module components.

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high

More information

Non-Contact Sensor for Workpiece Placement Verification

Non-Contact Sensor for Workpiece Placement Verification ir Catch Sensor Series 2 Non-Contact Sensor for Workpiece Placement Verification Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M. V3 Cover

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308 Cable ppendix Cable ppendix Multi-way cables The multi-pole connector cables used on SMC valves are common across several ranges. Cables are available in accordance with the MIL standard C-08 and also

More information

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch -Color Display Digital Pressure Switch (F)/(H) Series Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor unit: Stainless steel 630 Fitting parts: Stainless steel 304 The sensor unit

More information

Series ZM Applications

Series ZM Applications Ejector [Option] ll in One! Built-in suction filter and silencer ir supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and

More information

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000

More information

Easier maintenance. ZHP Series. Mounting with the lock plate reduces the pad replacement work steps! Uses an isolated structure. Application Examples

Easier maintenance. ZHP Series. Mounting with the lock plate reduces the pad replacement work steps! Uses an isolated structure. Application Examples Vacuum ad with Ejector Series ad Diameter: ø63, ø8 Ejector and pad are integrated. Space saving and reduced piping labor! Two-stage ejector More efficient ejector Suction flow rate 1) Compared with SMC

More information

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Series ZSE3/ISE3 2-color digital display allows you to choose the setting according to your application requirements. 4 different display settings

More information

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth!

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth! Digital Pressure Switch Series ZSE1(F)/ISE1 Low profile 26.1mm 9.8 mm 13.5 mm 53.4 mm Reduced in depth! (Actual size) RoHScompliant Vertical mounting space reduced to approx.! 1 2 Position Detection Switch

More information

Series ZM Applications

Series ZM Applications Ejector [Option] ll in One! Built-in suction filter and silencer ir supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)

More information

Series VQZ1000/2000/3000 Single Unit

Series VQZ1000/2000/3000 Single Unit +- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch Series ZSE3A(F)/ISE3A RoHS Can copy to up to 1 switches simultaneously. The settings of the master sensor can be copied to the slave sensors. Reducing

More information

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),

More information

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant -Colour Display Digital Pressure Switch Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor parts: Stainless steel 6 Fitting parts: Stainless steel 4 The sensor and fitting parts can

More information

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A) ort Solenoid Valve ubber Seal Series SY00 Low power consumption: 0.W (Standard, Without light) (Current draw: m at V DC) Large flow capacity style:0.7w (Current draw: m at V DC) Body width: 0mm 7.8 Nl/min

More information

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2 Series -PSE3 RoHS Remote Type 2-Color Display Digital Pressure Sensor Controller How to Order 2 3 4 5 Nil Options/Part No. L Input/Output specifications NPN2 output to 5 V output NPN2 output 4 to 2 m output

More information

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A 2-Color Display High-Precision Digital Pressure Switch Series ZSEA(F)/ISEA New M8 connector type RoHS IP65 Applicable fluid Air, Non-corrosive gas, Non-flammable gas Can copy to up to 10 switches simultaneously.

More information

Nozzle diameter: ø0.5, ø0.7, ø1.0, ø1.2. Features

Nozzle diameter: ø0.5, ø0.7, ø1.0, ø1.2. Features ariety of modularized units enable selections of integrated type ejector units suitable for the application. K eries Nozzle diameter: ø0.5, ø0.7, ø1.0, ø1.2 ZM Q G Y H U B C K KM J JM X XM Features acuum

More information

3 Port Solenoid Valve

3 Port Solenoid Valve 3 ort Solenoid Valve Series VKF300 ubber Seal Direct Operated oppet Type Compact yet provides a large flow capacity Body width 8 mm vailable in vacuum applications ( 0. ka) Can be used in vacuum/release

More information

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor 2-Color Display High-Precision Digital Pressure Switch ZSE ISE RoHS ZSE ISE IP65 ZSE40 ISE40 M8 connector type ZSE10 ISE10 ISE70 ZSE80 ISE80 PS ISA3 ISA2 ISE35 Applicable Air, Non-corrosive gas, Non-flammable

More information

Remote Type Pressure Sensors Pressure Sensor Controllers

Remote Type Pressure Sensors Pressure Sensor Controllers CT.EUS1-56B-UK Remote Type Pressure Sensors Pressure Sensor Controllers Compact Pressure Sensor for Pneumatics PSE53 Multi-channel Digital Pressure Sensor Controller PSE2 Compact Pressure Sensor for Pneumatics

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series

More information

Vacuum Ejector. Series ZM

Vacuum Ejector. Series ZM Ejector Series All in One! Built-in suction filter and silencer Air supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)

More information

Series 10-ZSE40A(F)/10-ISE40A

Series 10-ZSE40A(F)/10-ISE40A Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High Precision Digital Pressure Switch How to Order For positive pressure Clean series For vacuum/ compound pressure 01 N01 W1 10 Rated pressure range ISEA

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions -Color Display Digital Pressure Switch /75/75H Series NPN/PNP open collector outputs added. Zero-cut off display function added. For General Fluids For Air Rated Pressure Metal Body Type 0 5 (E75) () -Color

More information

Terminal Block Box (Spring Type) SY3000/5000/7000 Series

Terminal Block Box (Spring Type) SY3000/5000/7000 Series INFORMATION 5 ort olenoid alve Terminal lock ox (pring Type) Y3000/5000/7000 eries Compact RoH Height 6.7 mm shorter (Approx. 9% reduction) Installation area of the terminal block box Reduced by approx.

More information

Series ZM Applications

Series ZM Applications Ejector Series ZM All in One! Built-in suction filter and silencer Air supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)

More information

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type. Series -S00 ompact Direct Operated Port Solenoid Valve ontrol Valves ase mounted ody ported lean Series lean Series V S R oil voltage 24 VD VD VD VD VD Power consumption Pressure specification Flow rate

More information

Vacuum Ejector with Solid State Timer

Vacuum Ejector with Solid State Timer Vacuum Ejector with Solid State Timer Incorporates solid state timer function for release valve control (Timer setting with PLC is unnecessary) Timing Chart OFF Suction command ON Suction output OFF ON

More information

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector

More information

3, 5 port pilot operated valve Pneumatic valve / master valve. Discrete valve. Manifold

3, 5 port pilot operated valve Pneumatic valve / master valve. Discrete valve. Manifold K/K, pilot operated valve neumatic valve / master valve MNE0 MNE0 M MN W WG MNS0 MNS0 T L-/ S/0 S/ K/ F CONTENTS Safety precautions 776 Discrete valve ody ing (K/K to ) 868 Sub-plate ing (K to ) 87 Manifold

More information

Series SYJ300/500/700

Series SYJ300/500/700 ort Solenoid Valve ubber Seal Series SYJ00/00/00 Low power consumption: 0.W (Without light) (Current draw: 1m at 4V DC) Completely interchangeable ilot exhaust with the previous series VJ00/00/00 and VZ00/00.

More information

Example. U side. Stations SY5000

Example. U side. Stations SY5000 45 Type 5 ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN ail Mounted/Individual Wiring Series SY3000/5000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 3 45 05 U C6 Example

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series)

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series) 3-Screen Display High-Precision Digital Pressure Switch New Added Variations! For general fluids IP65 2 outputs Analog output Setting is possible while checking Main screen the measured value. Sub screen

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to

More information

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I ISO Standard Solenoid Valve Series VQ7-6/7-8 (Size ) (Size ) Conforms to ISO Standard /I.0- Ideal for driving cylinders up to Large flow capacity ø00 (VQ7-6, Size ) ø60 (VQ7-8, Size ) Nl/min VQ7-6: 668.

More information

Vacuum / Release Unit

Vacuum / Release Unit Rubber Seal Vacuum / Release Unit Series VQD1000-V Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area Smooth detachment of a work piece without over-blow

More information

Ejector Valve Unit Series ZYY/ZYX

Ejector Valve Unit Series ZYY/ZYX Ejector Valve Unit Series ZYY/ZYX Series ZYY3 (Solenoid valve: SY3) Nozzle diameter: ø.7, ø1. Type S: Standard type L: Large flow type Ejectors and solenoid valves can be mounted on the same manifold.

More information

Vacuum Ejector. Series ZM Applications

Vacuum Ejector. Series ZM Applications Ejector Series ZM All in One! Built-in suction filter and silencer Air supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) switch (solid state, diaphragm)

More information

How to Order. 0.5 mmø 0.7 mmø mmø mmø mmø mmø mmø. Maximum vacuum pressure S L. 88 kpa 48 kpa. SUP.

How to Order. 0.5 mmø 0.7 mmø mmø mmø mmø mmø mmø. Maximum vacuum pressure S L. 88 kpa 48 kpa. SUP. Vacuum Ejector How to Order Note Refer to Table (1) and (2) for the combination available for SUP, VAC and EXH port connection. ZH 07 B S 06 06 ZH 07 D S 01 01 01 Nozzle diameter 05 07 0.5 mmø 0.7 mmø

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics The ZSE3/E3 series is to be discontinued. We recommend you consider using the Z/E10 series or the

More information

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Vacuum / Release Unit Series VQD1000-V Rubber Seal Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area [Option] Smooth detachment of a work piece without

More information

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Soft Start-up Valve. AV2000/3000/4000/5000 Series Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

MULTISTAGE MICRO EJECTORS

MULTISTAGE MICRO EJECTORS MULTISTAGE MICRO EJECTORS MED07-E, MED10-E Specifications Basic model Item Media Operating pressure range MPa [psi.] Proof pressure MPa [psi.] Operating temperature range (atmosphere and media) C [ F]

More information

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal

More information

Vacuum Pad with Ejector

Vacuum Pad with Ejector IFORMTIO Vacuum ad with Ejector ad Diameter: ø63, ø8 RoHS Ejector and pad are integrated. Space saving and reduced piping labor! Bellows type with groove Two-stage ejector More efficient ejector Suction

More information

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS MULTISTAGE MICRO EJECTORS CONTENTS MED07-E, MED10-E Series Specifications 715 Order Codes 716 Operation Principle

More information

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles ort Solenoid Valve: ase Mounted Metal Seal/Rubber Seal Series Space and capacity saving ilot valve is gathered at one side. Space saving design which does not have any protrusions. Space saving Capacity

More information

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating / ort Solenoid Valve ubber Seal Series SYJ000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Specifications JIS Symbol port port (manifold) position

More information

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring Type4 SY000/000 ase Mounted Monifold Stacking Type/DIN ail Mounted Individual Wiring How to Order Manifold SSY 4 0 U C6 How to Order Valve Manifold ssembly Ordering example SY000 SY000 Valve stations 02

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

2-colour Display High Precision Digital Pressure Switch

2-colour Display High Precision Digital Pressure Switch High Precision, -colour Display Digital Pressure Switch -colour Display High Precision Digital Pressure Switch Series ZSE/ISE Features djustable vacuum, positive and compound pressure switch with display.

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

Vacuum System Peripherals

Vacuum System Peripherals Vacuum System Peripherals Vacuum Regulator/Electronic Vacuum Regulator Vacuum regulator: IRV0/0 Electronic vacuum regulator: ITV009/ITV09 Directional Control Valve Selection guide of directional control

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series

More information

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is. Port Solenoid Valve Series VQ 00 Unprecedented high speed, stable response, and extra-long service life. ON:.ms, OFF: ms, Dispension accuracy ±ms (With indicator light and surge voltage suppressor; supply

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE High Precision, 2-color Display Digital Pressure Switch Series SE30/ISE30 SE ISE PSE I SE3 PS I SE 1 2 SP ISA2 IS SM PF2 IF Data With One-touch fittings are newly introduced. Straight type Elbow type 16-2-1

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

Vacuum Ejector. Adaptable for manifold application

Vacuum Ejector. Adaptable for manifold application Vacuum Ejector Series ZM ZX All in One! Built-in suction filter and silencer Air supply valve for generating a vacuum Vacuum release valve (equipped with a flow volume adjustment valve) Vacuum pressure

More information

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot ubber seal ort ilot Solenoid Valve Series SYJ00 Specifications efer to www.smcworld.com for details of products compatible with overseas standards. Body ported Base mounted Fluid Operating pressure range

More information

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch -Color Display Digital Pressure Switch Series ZSE80(F)/ISE80(H) Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor parts: Stainless steel 630 Fitting parts: Stainless steel 304 The

More information

Compact and Lightweight. One-touch and screwin connections can be combined.

Compact and Lightweight. One-touch and screwin connections can be combined. Vacuum jector ox Style (uilt-in Silencer)/ody Ported Style Series Z SUP Nozzle diameter ø0.5, ø0.7, ø1.0, ø1.3, ø1.5, ø1.8, ø2.0 Style S: Standard : arge low apacity ompact and ightweight X The nozzle

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve ubber Seal / ort Solenoid Valve Series 000 / 000 / 000 [Option] SJ SY SV SZ V S000 VQ VQ VQ VQC VQZ SQ VFS VF VQ Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions Series ISE70/75/75H NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. For General Fluids For Air 2-Color Display (Green/Red) Selectable from four patterns ON Red Green Red Green

More information

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A Type N SY/ ase ounted anifold Stacking Type/DIN Rail ounted Connector ox How to Order anifold SSY SY SY Specifications Symbol Specifications With connector box (CO spec.) N With connector box ( CO spec.)

More information

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1 Port Solenoid Valve Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Non plug-in manifold 0 0 S 60 Stations stations 0 stations SUP/EXH

More information