3 Port Air Operated Valve. SYJA300 Series. How to Order. Nil Without sub-plate. Type of actuation. Normally closed Normally open
|
|
- Dwayne Hancock
- 6 years ago
- Views:
Transcription
1 3 ort ir Operated Valve SYJ300 Series How to Order SYJ3 M3 Bracket Nil Without bracket F With bracket *The bracket is not mounted. *The bracket cannot be retrofitted later. SYJ3 Type of actuation Normally closed Normally open ort size Nil Without sub-plate M5 M5 port with sub-plate How to Order Manifold Base Same manifolds as SYJ300 series are prepared. SS3YJ3 Fill the same as SS3YJ3. Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base model no. (Ex.) SS3YJ3--03-M3... set SYJ... set SYJ... set SYJ set The asterisk denotes the symbol for assembly. refix it to the part nos. of the solenoid valve, etc. 536
2 3 ort ir Operated Valve SYJ300 Series Compact and lightweight Symbol SYJ3 SYJ3 () () () 3 () () 3 () Specifications Fluid ir Operating pressure range Ma 0.5 to 0.7 ilot pressure range Ma Note ) Operating pressure range to 0.7 mbient and fluid temperature ( C) 0 to 60 (No freezing) Lubrication Not required Mounting orientation Unrestricted Impact/Vibration resistance (m/s Note ) ) 50/30 Note ) Be certain that pressure within operating pressure range be supplied to supply port, because return pressure is introduced from supply port {()} for activation. Note ) Impact resistance: No malfunction resulted from the impact test using a drop impact tester. The test was performed on the axis and right angle directions of the main valve, when pilot signal is ON and OFF. (Value in the initial state) Vibration resistance: No malfunction occurred in one sweep test between 5 and 000 Hz. Test was performed to axis and right angle directions of the main valve when pilot signal is ON and OFF. (Value in the initial state) With Bracket ilot ressure ange ilot pressure Ma ir operated valve type ilot pressure range SYJ3 -M3-F Caution Be sure to read this before handling the products. efer to back page 50 for Safety Instructions and pages 3 to 9 for 3//5 ort Solenoid Valve recautions. SY SYJ VF VF V SYJ VT VG V V Operating pressure Ma Flow ate Characteristics/Weight Body ported Valve model (with sub-plate) SYJ3-M3 SYJ3-M3 SYJ-M5 SYJ-M5 Type of actuation Flow rate characteristics ort ( ) 3 ( ) size C [dm 3 /(s bar)] b Cv C [dm 3 /(s bar)] b Cv Note) Model No. for base mounted type without sub-plate is SYJ ilot port size Effective Weight (g) area (mm ) (Without subplate 8) 537
3 SYJ300 Series Dimensions : SYJ3 -M3(-F) x ø3.5 (8.) () (Non-locking) (,, port) (0) (6.).5 ø 0 (Bracket) 5 () : SYJ3 -M5 (Non-locking) x ø (For solenoid valve) (External pilot port) ø (,, port)
4 3 ort ir Operated Valve SYJ500/700 Series How to Order SY SYJ ort size Symbol M5 0 Bore size /8 pplicable series SYJ500 SYJ700 VF VF SYJ 5 SYJ Series SYJ500 SYJ700 Type of actuation M5 Normally closed Normally open Bracket Nil F Without bracket With bracket *The bracket is not mounted. Thread type Nil c F G N NT T NTF *Except M5 ort size Symbol Bore size pplicable series Nil Without sub-plate 0 /8 SYJ500 with sub-plate SYJ700 0 / with sub-plate SYJ700 V SYJ VT VG V V3 How to Order Manifold Base Same manifolds as SYJ500/700 series are prepared. (For SYJ500) SS3YJ5 (For SYJ700) SS3YJ7 Fill the same as SS3YJ5. Fill the same as SS3YJ7. Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base model no. (Ex.) SS3YJ set SYJ5... sets SYJ set (Ex.) SS3YJ set SYJ7... sets SYJ set The asterisk denotes the symbol for assembly. refix it to the part nos. of the solenoid valve, etc. 539
5 SYJ500/700 Series Specifications SYJ500 series Fluid Operating pressure range Ma ilot pressure range Ma Note ) mbient and fluid temperature ( C) Lubrication Mounting orientation Impact/Vibration resistance (m/s Note ) ) With Bracket ir 0.5 to 0.7 (0. x + 0.) to 0.7 : Operating pressure range 0 to 60 (No freezing) Not required Unrestricted 300/50 Note ) Be certain that pressure within operating pressure range be supplied to supply port, because return pressure is introduced from supply port {()} for activation. Note ) Impact resistance: No malfunction resulted from the impact test using a drop impact tester. The test was performed on the axis and right angle directions of the main valve, when pilot signal is ON and OFF. (Value in the initial state) Vibration resistance: No malfunction occurred in one sweep test between 5 and 000 Hz. Test was performed to axis and right angle directions of the main valve when pilot signal is ON and OFF. (Value in the initial state) ir operated valve type SYJ5 -M5-F, SYJ7-0-F Note) The bracket is not mounted. SYJ700 series Symbol SYJ5 SYJ5 SYJ7 SYJ7 () () () 3 () () 3 () Bracket assembly part no. pplicable series SYJ SYJ500 SYJ SYJ700 *Mounting screws included. ilot ressure ange ilot pressure Ma ilot pressure range Operating pressure Ma Caution Be sure to read this before handling the products. efer to back page 50 for Safety Instructions and pages 3 to 9 for 3//5 ort Solenoid Valve recautions. Flow ate Characteristics/Weight Flow rate characteristics Type of ort Valve model ( ) 3 ( ) actuation size C [dm 3 /(s bar)] b Cv C [dm 3 /(s bar)] b Cv SYJ5-M SYJ5-M SYJ /8 (with sub-plate) SYJ SYJ /8 SYJ SYJ7-0 / SYJ7-0 / (with sub-plate) SYJ7-0 / SYJ7-0 / Note) Model No. for base mounted type without sub-plate is SYJ5, SYJ ilot port size Weight (g) 6 (Without subplate ) 6 (Without subplate 6) 50
6 3 ort ir Operated Valve SYJ500/700 Series Dimensions SYJ500 Series : SYJ5 -M5(-F).5 8 (.3) x (Mounting screw) (Bracket) SYJ700 Series : SYJ7-0 (-F) x ø.6 (For manifold mounting) 8.5 x ø.6.5 (,, port) Manual override (8) (5) ø.3 x ø3. (For manifold mounting) x ø3.5 (30) (37) : SYJ x ø.5 ø.3 6 /8 ( port) 0 : SYJ7 - /8,/ ( port) (External pilot port) (For solenoid valve) 8.5 /8 (, port) X SY SYJ VF VF V SYJ VT VG V V3 3.5 x M x 0.7 (Mounting screw) 3.5 x ø3. x ø (3.6) 5. 8 (6) () (36) () 6.5 /8 (,, port) 8 (Bracket) Manual override x ø.3 (External pilot port) (For solenoid valve) X 0.8 ø.8 ø.8 0 /8,/ (, port)
4/5 Port Air Operated Valve. SYJA3000 Series. How to Order. (Manifold use only) Type of actuation. 2 position single. 3 position closed center
4/ ort ir Operated Valve SYJ000 Series How to Order ody ported SYJ M racket Nil Without bracket F With bracket *Refer to page 47 for the details of the brackets. ase mounted (4 port) SYJ 2 0 (Manifold
More informationRubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot
ubber seal ort ilot Solenoid Valve Series SYJ00 Specifications efer to www.smcworld.com for details of products compatible with overseas standards. Body ported Base mounted Fluid Operating pressure range
More informationSeries SYA3000/5000/7000
1 Port Air Operated Valve Series SYA000/000/7000 Body ported Base mounted Base mounted How to Order A, B port size Thread type Thread piping (Inch size) Nil Rc Symbol Port size Applicable series Symbol
More informationSeries SYA3000/5000/7000
Port Air Operated Valve Series SYA000/000/7000 How to Order A, B port size Thread type Thread piping (Inch size) - Rc Symbol Port size Applicable series Symbol Port size Applicable series F G SYA000 N
More informationSeries SYA3000/5000/7000
Port Air Operated Valve Series SYA000/000/7000 How to Order A, B port size Thread type Thread piping (Inch size) Nil Rc Symbol Port size Applicable series Symbol Port size Applicable series F G M SYA000
More informationSeries SYA3000/5000/7000
Port Air Operated Valve Series SYA000/000/7000 How to Order A, B port size Thread type Thread piping (Inch size) Nil Rc Symbol Port size Applicable series Symbol Port size Applicable series F G M SYA000
More information3 Port Solenoid Valve
ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M. V3 Cover
More information2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating
/ ort Solenoid Valve ubber Seal Series SYJ000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Specifications JIS Symbol port port (manifold) position
More information5 Port Air Operated Valve
Port ir Operated Valve Series VF000/000/000 RoHS 22- Series VF000/000/000 Model Selection by Operating Conditions q ir Operated Valve: Single Unit Series Sonic conductance C[dm /(s bar)] Type of actuation
More information4/5 Port Solenoid Valve
CT.ES8 / ort Solenoid Valve Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M.7 to M2. 앬 Flow Characteristics Series Cover (stainless
More information3 Port Solenoid Valve
3 ort Solenoid Valve Series VKF300 ubber Seal Direct Operated oppet Type Compact yet provides a large flow capacity Body width 8 mm vailable in vacuum applications ( 0. ka) Can be used in vacuum/release
More informationSeries SYJ300/500/700
ort Solenoid Valve ubber Seal Series SYJ00/00/00 Low power consumption: 0.W (Without light) (Current draw: 1m at 4V DC) Completely interchangeable ilot exhaust with the previous series VJ00/00/00 and VZ00/00.
More informationPower Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit
CT.EUS8 UK ower Consumption / ort Solenoid Valve With ower Saving Circuit Series SYJ000/000/7000 Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced
More information4/5 Port Solenoid Valve
ubber Seal / ort Solenoid Valve Series 000 / 000 / 000 [Option] SJ SY SV SZ V S000 VQ VQ VQ VQC VQZ SQ VFS VF VQ Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread
More informationFluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single
Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position
More information3 Port Air Operated Valve
Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation
More informationSeries VQZ1000/2000/3000 Single Unit
+- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body
More information5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted
Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted
More informationSYA3000/5000/7000. How to Order SYA3000 SYA5000. Bracket One-touch fitting for ø8 G 1 4 With foot bracket. F1 One-touch fitting for ø8 SYA7000 G 1 8
Port Air Operated Valve SYA000/000/7000 How to Order Symbol M C6 01F C6 02F C10 Without bracket A/B port size Port size Series M One-touch fitting for ø4 SYA000 One-touch fitting for ø6 G 1 8 One-touch
More information5 Port Air Operated Valve. Specifications. Flow characteristics 1 4/2(P A/B) Cv
5 Port Air Operated Valve Series 000 Model (With sub-plate) Valve model -M5 -M5 3-M5 -M5 --0 --0 --0 --0 3--0 3--0 --0 --0 position 3 position position 3 position Type of actuation Single Double Closed
More informationSeries SV1000/2000/3000/4000
Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double
More informationSeries VP3145/3165/3185
Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to
More informationSeries VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4
Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double
More information5 Port Solenoid Valve
ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high
More information5 Port Air Operated Valve. How to Order. Port size. (A, B port) R port of VFA3 70 is 1/4.
Port Air Operated Valve Series VFA000 How to Order Body ported single solenoid Foot bracket VFA22 Port size (P, A, B port) 0 8 4 R, R2 port are /8. F Thread type (Including pilot port) F N T Rc G NPT NPTF
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body
More informationExample. U side. Stations SY5000
45 Type 5 ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN ail Mounted/Individual Wiring Series SY3000/5000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 3 45 05 U C6 Example
More information5 Port Solenoid Valve
Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size
More information5 Port Solenoid Valve
ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body
More information5 Port Solenoid Valve
ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series
More informationIndicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A
1 3 Port Air Operated Valve Series VTA301 JIS Symbol VTA 301 Indicate VO for manifold. Port size Specifications How to Order Without connection port (For manifold) 01 1/8 02 1/4 Option Fluid Air Operating
More information0.35 W (Without light)
Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body
More informationSeries VKF300 VV061 V100 S070 VQD VKF VK VT VS
Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing
More informationSeries SYJ3000/5000/7000
, ort Solenoid Valve ubber Seal Series SYJ000/000/7000 Low power consumption: 0.W(Without light) (Current draw: 1m at V DC) right color tone and state of the art design SY SYJ SX VK VZ VF VF V7 V Completely
More informationSeries VQ Port Solenoid Valve
Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors
More informationI N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications
I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000
More information0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types
Speed 2 Port Valve Series RoHS speed speed speed response response response 5 ms 9mm Width ±0.05 ms ±0.05 ms type VCH : : 5 ms * The response time is measured based on SMC test conditions. (Not guaranteed
More informationQ1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.
Multistage Ejector 112/212 Series Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus
More information1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions
Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]
More information5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure
For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Series 000 Compact and lightweight: 3 mm width Compact yet provides
More information3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option
3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity
More information3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)
ort Solenoid Valve ubber Seal Series SY00 Low power consumption: 0.W (Standard, Without light) (Current draw: m at V DC) Large flow capacity style:0.7w (Current draw: m at V DC) Body width: 0mm 7.8 Nl/min
More information5 Port Solenoid Valve
5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry
More information3 Port Solenoid Valve
Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly
More information5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal
Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage
More informationVQ1000. How to Order Manifold. Kit type
- - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold
More informationSeries SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A
Type N SY/ ase ounted anifold Stacking Type/DIN Rail ounted Connector ox How to Order anifold SSY SY SY Specifications Symbol Specifications With connector box (CO spec.) N With connector box ( CO spec.)
More informationISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I
ISO Standard Solenoid Valve Series VQ7-6/7-8 (Size ) (Size ) Conforms to ISO Standard /I.0- Ideal for driving cylinders up to Large flow capacity ø00 (VQ7-6, Size ) ø60 (VQ7-8, Size ) Nl/min VQ7-6: 668.
More informationManifold Specifications
Series 00 Manifold Specifications Manifold Specifications Model Manifold type P(SUP)/R(EXH) Valve stations A port porting specifications Port size For internal pilot For external pilot Location Direction
More informationSpecifications. Fluid Ambient and fluid temperature ( C)
Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication
More informationCable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308
Cable ppendix Cable ppendix Multi-way cables The multi-pole connector cables used on SMC valves are common across several ranges. Cables are available in accordance with the MIL standard C-08 and also
More informationSeries SY3000/5000 How to Order Manifold
Type N ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN Rail Mounted/Connector ox SY/ How to Order Manifold SSY SY SY Specifications Symbol Specifications With connector box (COM spec.) N With
More information3 Port Solenoid Valve Direct Operated Poppet Type
3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage
More informationExhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)
5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust
More informationATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry
Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 044 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000 racket
More informationSeries SY3000/5000/7000
Type20P 5 Port Solenoid Valve ody Ported Manifold ar Stock Type/Flat Ribbon Cable Series SY3000/5000/7000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 5 20P 05 Manifold series 3 SY3000
More informationSeries VP3145/3165/3185
Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes
More informationATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry
TEX Compliant Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 44 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000
More information5 Port Solenoid Valve Direct Operated Poppet Type. Specifications
Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W
More information5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC)
Port Solenoid Valve/Direct Poppet Rubber seal Series VK3000 Nl/min 147 Compact/Width 18 X Length 8 (mm) Low power consumption 4W DC (Standard) 2W DC (Energy saver) Standard copper free specification All
More informationSS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring
Type4 SY000/000 ase Mounted Monifold Stacking Type/DIN ail Mounted Individual Wiring How to Order Manifold SSY 4 0 U C6 How to Order Valve Manifold ssembly Ordering example SY000 SY000 Valve stations 02
More information5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles
ort Solenoid Valve: ase Mounted Metal Seal/Rubber Seal Series Space and capacity saving ilot valve is gathered at one side. Space saving design which does not have any protrusions. Space saving Capacity
More informationPilot Operated 2 Port Solenoid Valve for Dry Air
Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0
More information3 Port Air Operated Valve VTA. Indicate VO for manifold. Port size. Nil 02 1/4. Specifications Fluid. Option Description Bracket (With screw)
Series VTA301 How to Order VTA 301 Indicate VO for manifold. Port size Without connection port (For manifold) 01 1/8 02 1/4 F N T Option B Rc G NPT NPTF Without bracket Foot bracket JIS Symbol Specifications
More informationRubber Seal VP300/500/700
Port Pilot Operated Poppet Rubber Seal 00/500/700 High flow capacity Cv1.0 (00), Cv. (500), Cv.0 (700) Low power consumption: 1.8W(DC) Possible to use as either selector valve or divider valve Changeable
More informationSeries SY3000/5000/7000
Type1P Type2P 5 Port Solenoid Valve ase Mounted Manifold ar Stock Type/Flat Ribbon Cable Series /5000/000 How to Order Manifold Type 1P/Compact style SS5Y 5 1P 05 C8 Manifold series 3 5, port size Thread
More informationTerminal Block Box (Spring Type) SY3000/5000/7000 Series
INFORMATION 5 ort olenoid alve Terminal lock ox (pring Type) Y3000/5000/7000 eries Compact RoH Height 6.7 mm shorter (Approx. 9% reduction) Installation area of the terminal block box Reduced by approx.
More informationSeries VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non
Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non
More informationOption. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications
Series -SQ00 Port Solenoid Valve Plug-in Unit [Option] How to Order Manifold Electrical entry F kit D-sub connector kit P kit SSQ 08 FD Kit type Flat ribbon cable connector kit J kit Flat ribbon cable
More information3GA1/2/3, 4GA1/2/3 Series Applicable cylinder bore size: ø20 to ø100
MNE0 M Discrete master valve, manifold (metal base) Body porting GA/2/, GA/2/ Series Applicable cylinder bore size: ø20 to ø0 MN W2 WGB MNS0 MNS0 TB L2-/ SA/B0 SA/B KA/B F Common specifications Descriptions
More informationSeries SYJ Way 4 and 5 Port. Rubber Seal Solenoid Pilot Valve
N Way and ort Series SYJ000 ubber Seal Solenoid ilot Valve ODUCTS Interchangeable with the NVJ Series Low ower Consumption: 0.W ase Mounted/ody orted Configurations Manifolds with uilt-in One-Touch Fittings
More informationVacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm
4 Port Direct Operated Poppet Solenoid Valve Series D1000 High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure
More informationD-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector
Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),
More information3, 5 port pilot operated valve Pneumatic valve / master valve. Discrete valve. Manifold
K/K, pilot operated valve neumatic valve / master valve MNE0 MNE0 M MN W WG MNS0 MNS0 T L-/ S/0 S/ K/ F CONTENTS Safety precautions 776 Discrete valve ody ing (K/K to ) 868 Sub-plate ing (K to ) 87 Manifold
More information3 Port Solenoid Valve
Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series
More information10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry
Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position
More information10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection
Rubber Seal Port Solenoid Valve Series SJ000/000 Cassette Type Manifold 0 mm 7. mm (SJ000) 0 mm (SJ000) Non plug-in type Individual wiring manifold SJ000 SJ000 Can be mounted together. Connecter connection
More informationManual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry
Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal
More informationFlow characteristics Max. (1) b Standard Specifications. P Manual override.
Port Direct Operated Solenoid Valve Series 0 Metal Seal Model Number of positions (Single) (Double) ( position) JIS Symbol Model Port size Rc (Nominal size) 0-0 8 ( A) 0- ( 8A) 0-0 8 (0A) 0-0 8 ( A) 0-
More information3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot
3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in
More informationD-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000
D-sub Connector J Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000//000 Number of connectors: pins MIL-C-08 Conforming to JIS-X-0 --6 For details
More information5 Port Solenoid Valve Direct Operated Poppet Type. Specifications
Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3
More informationGateway System Serial Transmission System
Gateway System Series 00 I compliant V S000 C Tie-rod base Z pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000/000/000 Number of output points: points Connected to the 00GW
More information5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range
For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR2 JIS Symbol type
More informationBase Mounted Plug-in/Plug Lead: Single Unit
ase mounted VQ ase Mounted lug-in/lug Lead: Single Unit Model Number of solenoids Model Single Metal seal VQ Rubber seal VQ ouble Metal seal VQ Rubber seal VQ Closed Metal seal VQ VQ center Rubber seal
More informationVacuum System Peripherals
Vacuum System Peripherals Vacuum Regulator/Electronic Vacuum Regulator Vacuum regulator: IRV0/0 Electronic vacuum regulator: ITV009/ITV09 Directional Control Valve Selection guide of directional control
More information5 Port Solenoid Valve
Metal seal Port Solenoid Valve Series VQ Rubber Seal Space-saving profile Clean space saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less
More informationCoolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations
Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) type (3 to ) Low water hammer or details, refer to page 07. Large
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model 2 position 3 position
More information3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.
3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118
More informationCoolant Valve. Air Operated/External Pilot Solenoid
Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) lange type (3 to ) Low water hammer or details, refer to page
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time
More informationHow to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1
Port Solenoid Valve Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Non plug-in manifold 0 0 S 60 Stations stations 0 stations SUP/EXH
More informationBody width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.
High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure of 0.5MPa, subject to clean, dry air) 4 Port Direct
More informationNew Concept Connector Type Manifold
New Concept Connector Type Manifold Series /000/3000/000 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration.
More information4 Port Solenoid Valve
Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean