1 Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option] RoHS single valve with various valve functions (Universal porting type) N.C. valve Divider valve N.O. valve Selector valve etc Low concentration ozone resistant Rubber seal material: HNBR for main valve Mounting dimensions are interchangeable with current product VV06 VV00 V00 Body ported type Manifold type S070 VQD VQD-V VK VT 4

2 VT07 Series Port Solenoid Valve Direct Operated Poppet Type variety of valve options Continuous duty type Vacuum specification type Energy-saving type Energy-saving type + Vacuum specification type pplication examples q Blow-off valve w Pressure release valve e Selector valve r Valve for vacuum (P) (R) (P) (R) X Plug P P2 (P) (R) Vacuum pump (P) (R) Vacuum pad Vacuum releasing air tmospheric pressure or micro pressure t Divider valve y Single-acting cylinder drive u Double-acting cylinder drive i Double-acting cylinder drive (Exhaust center) Tank (P) (R) Tank (P) (R) 2 () N.C. (P) (R) (P) N.O. (R) N.C. (P) (R) (P) N.C. (R) Port Solenoid Valve, Universal Porting Type Variations Poppet type Direct operated poppet type Pilot poppet type Series VT07 VT7 VT25 VP00/500/700 Cv (P ) to.6 Page Page 4 Page 44 Page 449 Page 26 42

3 Port Solenoid Valve Direct Operated Poppet Type VT07 Series Rubber Seal RoHS [Option] Note) CE compliant: Electrical entry is applicable only for the DIN terminal. How to Order V T 07 5 G 0 F T O Body type Body ported For manifold Valve option Nil Standard type E Continuous duty type Y Energy-saving type V Vacuum specification type W Energy-saving type, Vacuum specification type Semi-standard Pressure specifications Nil Standard type (0.7 MPa) K High-pressure type ( MPa) Semi-standard Grommet Rated voltage 00 VC, 50/60 Hz VC, 50/60 Hz 0 VC, 50/60 Hz VC, 50/60 Hz 5 24 VDC 6 2 VDC VC, 50/60 Hz Semi-standard Electrical entry DIN terminal Thread type Nil Rc F G N NPT T NPTF CE-compliant Nil None Q CE-compliant Electrical entry and light/surge voltage suppressor: D/DO/DZ/DOZ only Bracket Nil None F With bracket Port size Nil Without port (For manifold) 0 /8 (6) 02 /4 (8) Light/Surge voltage suppressor Nil None With surge voltage suppressor S (Grommet type only) With light/surge voltage suppressor Z (DIN terminal type only) With surge voltage suppressor G: 00 mm lead wire H: 600 mm lead wire D: With connector DO: Without connector Symbol (R) ()2 (P) Manifold Model pplicable manifold type ccessories Function plate (DXT52-4-) VO07 (-Q) Common or individual exhaust Note) Mounting screw (NXT0-) Note) It is not applicable to the continuous duty type. Refer to the accessories on page 47. Option Description Bracket Part no. DXT (With screw) Surge voltage suppressor 4 VV06 VV00 V00 S070 VQD VQD-V VK VT

4 VT07 Series Make sure that dust and/or other foreign materials do not enter the valve from the unused port (e.g. exhaust port). Flow Rate Characteristics/Weight Standard Specifications Type of actuation Fluid Operating pressure range mbient and fluid temperature Response time Note ) Max. operating frequency Lubrication Mounting orientation Impact/Vibration resistance Enclosure Electrical entry Coil rated voltage (V) llowable voltage fluctuation Note ) Note 4) pparent power C Power consumption Light/Surge voltage suppressor (DIN terminal type only) Note ) Note 4) Note 2) Direct operated type 2 position single solenoid ir 0 to MPa (High-pressure type), 0 to 0.7 MPa (Standard type) 0 to 50 C (No freezing) 20 ms or less (at 0.5 MPa) 0 Hz Not required (Use turbine oil Class ISO VG2, if lubricated.) Non-locking push type Unrestricted 50/50 m/s 2 Dustproof C (50/60 Hz) DC Inrush Holding DC C DC Grommet, DIN terminal 00, 200, 0, 220, , 2 5 to +0% of rated voltage 2.7 V (50 Hz), 0.7 V (60 Hz) 7.6 V (50 Hz), 5.4 V (60 Hz) Without indicator light: 4 W, With indicator light: 4.2 W Varistor, LED Diode, LED Semi-standard Note ) Based on dynamic performance test, JIS B 849: 200. (Coil temperature: 20 C, at rated voltage, without surge voltage suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Note ) t rated voltage Note 4) The value is different for continuous duty type (VT07E), and energy-saving type (VT07Y/W). Refer to Valve Options shown below. Valve model Flow rate characteristics Port 2 (P ) 2 ( R) 2 (R ) 2 ( P) size C [dm /(s bar)] b Cv C[dm /(s bar)] b Cv C[dm /(s bar)] b Cv C[dm /(s bar)] b Cv VT07 VT07V (Vacuum spec. type) VT07E (Continuous duty type) /8 VT07Y (Energy-saving type) VT07W (Energy-saving, Vacuum spec. type) VT07 VT07V (Vacuum spec. type) VT07E (Continuous duty type) /4 VT07Y (Energy-saving type) VT07W (Energy-saving, Vacuum spec. type) Note) Values for a single valve unit. It is not applicable to the manifold. Refer to the manifold specifications on page 47. Weight Grommet 0.5 kg Valve Options Continuous duty type: VT07E Exclusive use of VT07E is recommended for continuous duty with long time loading.. This model is for continuous duty, not for high cycle rates. But even in low cycle rates, if energizing the valve more than once a day, please consult with SMC. 2. Energizing solenoid should be done at least once in 0 days. Specifications different from standard are as follows. pparent power/ Inrush 7.9 V (50 Hz), 6.2 V (60 Hz) C Holding 5.8 V (50 Hz),.5 V (60 Hz) Power consumption/dc.8 W, With indicator light: 2 W Response time Note) 0 ms or less (at 0.5 MPa) Note) Refer to Note ) of the standard specifications. 44 Energy-saving type: VT07Y (VT07W) If low power consumption is required for electronic control, VT07Y(W) (.8 W) is recommended. Specifications different from standard are as follows. Power consumption/dc.8 W, With indicator light: 2 W Response time Note) 25 ms or less (at 0.5 MPa) Note) Refer to Note ) of the standard specifications. Vacuum spec. type: VT07V (VT07W) This vacuum model has less air leakage than the standard model under low pressure. It is recommended for vacuum application. Since this valve has slight air leakage, it can not be used for vacuum holding (including positive pressure holding) in the pressure container. Specifications different from standard are as follows. Operating pressure range 0.2 kpa to 0. MPa

5 2 Port Solenoid Valve Direct Operated Poppet Type VT07 Series Construction De-energized r Energized t Light/Surge Voltage Suppressor C In the case of indicator light Terminal no. q r y u q Terminal no. 2 DC In the case of indicator light Coil Terminal no. (+) (Å) ( ) (Â) Operation principle <De-energized> Poppet valve w is pushed upward by the return spring e, port is closed. Then, port and port are connected. ir flow direction: Port Block, Component Parts No. Description Material 2 4 Body Poppet valve Return spring Molded coil luminum die-casted luminum, HNBR Stainless steel Resin How to Use DIN Terminal w e. Disassembly ) fter loosening the screw q, then if the housing w is pulled in the direction of the screw q, the connector will be removed from the body of equipment (solenoid, etc.). 2) Pull the screw q out of the housing w. ) On the bottom part of the terminal block e, there s a cut-off part o. If a small flat head screwdriver is inserted between the opening in the bottom, terminal block e will be removed from the housing w. 4) Remove the cable gland r, plain washer t and rubber seal y. 2. Wiring ) Pass the cable u through the cable gland r, plain washer t and rubber seal y in this order, and then insert them into the housing w. 2) Loosen the screw! attached to the terminal block e. Then, pass the lead wire!0 through the terminal block e and tighten the screw! again. Note ) Tighten within the tightening torque of 0.5 N m ±5%. Note 2) Cable u outside diameter: ø6 to ø8 mm Note ) Crimped terminal like round-shape or Y-shape cannot be used. Connector for DIN Terminal Description Part no. BB09-2 (Standard) DIN connector GM209NJ-B7 (CE-compliant) (Å) (Â) <Energized> When energizing the molded coil r, the armature t is magnetically attracted to the core y, and through the push rod u, it pushes down the poppet valve w and port is closed. Then, port and port are connected. t this time, there will be gaps between the armature t and the core y, but the armature t will be magnetically firmly attracted to the core y. ir flow direction: Port Port, Port Block Note Color: White. ssembly ) Pass the cable u through the cable gland r, plain washer t and rubber seal y in this order and connect to the terminal block e. Then, mount the terminal block e on the housing w. (Push it down until you hear the click sound.) 2) Put the rubber seal y and plain washer t in this order into the cable entry of the housing w, and then tighten the cable gland r securely. ) Insert the gasket i between the bottom part of terminal block e and the plug attached to the equipment. Then, screw in q from the top of the housing w to tighten it. Note ) Tighten within the tightening torque of 0.5 N m ±20%. Changing the entry direction The orientation of a connector can be changed 80, depending on the combination of a housing w and a terminal block e. e i q w o!!0 y t u r ( ) w e Terminal no. 2 ( ) Electrical Connection DIN terminal is connected inside as in the figure below. Connect to the corresponding power supply. DIN terminal block 2 pplicable cable O.D. ø6 to ø8 Voltage 00 VC 200 VC DC Others Ground Terminal no. DIN terminal Lead Wire Color Coil 2 + Color Blue Red Red (+), Black ( ) Gray VV06 VV00 V00 S070 VQD VQD-V VK VT 45

6 VT07 Series Dimensions Grommet: VT07- G (Non-locking) 2 x ø4.5 (For mounting) (4.5) (4.5) Note) There is also VT07- H (lead wire length: 600 mm). (Non-locking) pplicable cable O.D. ø6 to ø8 (42) () (7.2) 2 x ø4.5 (For mounting) (4.5) (4.5) (28) (7) (4.5) Pg9 Max (42) () (7.2) (4.5) (28) (7) G: 00 H: 600 (Lead wire length) (.2) /4", /8" (Piping port) M4 x 0.7 thread depth 7 (Mounting screw) 25 DIN terminal: VT07- D (.2) /4", /8" (Piping port) 46 M4 x 0.7 thread depth 7 (Mounting screw) 25

7 VT07 Series Manifold Specifications VT07 manifold is available both as a common exhaust and individual exhaust model. Manifold valve can be easily converted from N.C. (Normally Closed) to N.O. (Normally Open) merely by turning over the function plate. Common exhaust VV F Individual exhaust VV F VV07 VT07 manifold How to Order Manifold Base F Dummy symbol Valve stations 02 2 stations stations Max. 20 stations Specify model number of the manifold base, applicable valves and blanking plates when ordering. Refer to page 4 for the model number of the valves. Ordering example: VV F pc. (5 station manifolds base) VO07-G 4 pcs. DXT pc. (Blanking plate) Manifold Specifications Manifold type Max. number of stations pplicable solenoid valve Exhaust port Symbol Type 2 Common Individual P Base (Side) 8 Base (Side) port size (Base mounted) common exhaust/individual exhaust 4 individual exhaust Exhaust port type 2 Common exhaust Individual exhaust Mounting bracket Thread type Nil F N T Rc G NPT NPTF B mount 20 stations Note) VO07 - (-Q) Port location (Direction)/Port size R Base (Side) Base (Side) 8 8 Base (Side) Base (Top) 4 8, 4 8 Note) For 6 stations or more, supply air both sides of P port. The common exhaust type should exhaust from both of the R port. Option Description Blanking plate (With gasket, screw) Note) Part no. DXT B Flow Rate Characteristics/Weight ccessories for pplicable Solenoid Valve Description Part no. Qty. Function plate (With gasket) Note) Mounting screws DXT52-4- B NXT0- pc. 2 pcs. Note) DXT060-5-B, DXT52-4-B are for the continuous duty type. Flow rate characteristics Valve model 2 (P ) 2 ( R) 2 (R ) 2 ( P) VO07 VO07V (Vacuum spec. type) VO07E (Continuous duty type) C[dm /(s bar)] 0.4 b 0.28 Cv C[dm /(s bar)] 0.4 b 0.22 Cv C[dm /(s bar)] 0.6 b 0.28 Cv 0.09 C[dm /(s bar)] 0.4 b 0.8 Cv VO07Y (Energy-saving type) VO07W (Energy-saving, Vacuum spec. type) Weight Grommet 0.5 kg VV06 VV00 V00 S070 VQD VQD-V VK VT 47

8 R P VT07 Series Dimensions: Common Exhaust VV F G: 00 H: (Pitch) 2 P = 26 8 L2 20 L Max. 0 P R DIN terminal (D, DZ) pplicable cable O.D. ø6 to ø8 Pg9 Grommet (G, H) (Non-locking) For 4 x M4 (For mounting) /8" [(P), (R) port] (Station n) (Station ) (5) 40 /8" [ port] (Pitch) P = 26 L Dimension L n 2 L L n: Stations Formula L = 26 x n + 6 L2 = 26 x n

9 Port Solenoid Valve Direct Operated Poppet Type VT07 Series Dimensions: Individual Exhaust VV F 25 (Pitch) P = 26 Pg DIN terminal (D, DZ) pplicable cable O.D. ø6 to ø8 Grommet (G, H) G: 00 H: (Non-locking) For 4 x M4 (For mounting) 27 R R P (Pitch) /8" 9.5 P = 26 [(R) port] 2 6 L2 /4" [(P) port] 8.5 Max. 0 () L (Station ) (Station n) (Pitch) P = 26 /4", /8" [ port] 62.5 VV06 VV00 V00 L Dimension L n 2 L L n: Stations Formula L = 26 x n + 24 L2 = 26 x n + 2 S070 VQD VQD-V VK VT 49

10 VT07 Series Specific Product Precautions Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages to 9 for /4/5 Port Solenoid Valve Precautions. Warning Mounting When mounting a valve on the manifold base, N.C. and N.O. can be reversed by the function plate orientation. lso, since the cylinder operates in reverse, confirm if the function plate is correctly mounted or not. N.C. specification N.O. specification Changing from N.C. to N.O. This product is delivered as N.C. valve. If N.O. valve is required, remove mounting screws of the required valve and turn over the function plate. (Make sure that there are gaskets on both sides of the plate.) Then, tighten the mounting screws to fix the valve to the manifold base. Port z Port x Port c Port positions for manifold solenoid valve body Function plate Figure: For N.C. Function plate Specifications N.C. N.O. Function plate No mark NO. Each valve is fixed to the manifold base with two M4 mounting screws. Tighten the screws firmly when re-mounting. 2. For mounting, tighten M4 or equivalent screws evenly into the mounting holes of the manifold base. Tightening torque of the mounting screw (M4):.4 N m Piping. For the common exhaust type, pressurization or evacuation of the (R) port can cause a malfunction. 440

1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption

1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption Port Solenoid Valve Direct Operated Poppet Type Power consumption Vacuum applications New [Option] RoHS 4 Standard wtype (Existing product: 4.8 W) 0. kpa Energy-saving type.8 w (Existing product: W) A

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot 3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in

More information

3 Port Solenoid Valve

3 Port Solenoid Valve 3 ort Solenoid Valve Series VKF300 ubber Seal Direct Operated oppet Type Compact yet provides a large flow capacity Body width 8 mm vailable in vacuum applications ( 0. ka) Can be used in vacuum/release

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum 3 Port Direct Operated Poppet Rubber Seal Series 307 Large Flow Capacity, yet Compact Size. Dimensions (W X H X D) 30 X 54.5 X 33 307 Nl/min 206.02 or more, 1/4 Low Power Consumption /VO307 4.8W DC/Standard

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series

More information

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Indicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A

Indicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A 1 3 Port Air Operated Valve Series VTA301 JIS Symbol VTA 301 Indicate VO for manifold. Port size Specifications How to Order Without connection port (For manifold) 01 1/8 02 1/4 Option Fluid Air Operating

More information

High Pressure Coolant Valve

High Pressure Coolant Valve High Pressure Coolant Valve Series.5 MPa, 7.0 MPa Corresponding to high speed grinding and long drilling processes Coolant valve for high pressure coolant liquid (up to.5 MPa or 7.0 MPa) that is ideal

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

0.35 W (Without light)

0.35 W (Without light) Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

Exclusively for air pressure system and air-hydro circuit control

Exclusively for air pressure system and air-hydro circuit control Process Valve Series Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external

More information

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Vacuum / Release Unit Series VQD1000-V Rubber Seal Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area [Option] Smooth detachment of a work piece without

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000) 5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust

More information

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control Process Valve Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external pilot

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

5 Port Air Operated Valve

5 Port Air Operated Valve Port ir Operated Valve Series VF000/000/000 RoHS 22- Series VF000/000/000 Model Selection by Operating Conditions q ir Operated Valve: Single Unit Series Sonic conductance C[dm /(s bar)] Type of actuation

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Series 000 Compact and lightweight: 3 mm width Compact yet provides

More information

Vacuum / Release Unit

Vacuum / Release Unit Rubber Seal Vacuum / Release Unit Series VQD1000-V Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area Smooth detachment of a work piece without over-blow

More information

Series SV1000/2000/3000/4000

Series SV1000/2000/3000/4000 Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double

More information

3 Port Air Operated Valve VTA. Indicate VO for manifold. Port size. Nil 02 1/4. Specifications Fluid. Option Description Bracket (With screw)

3 Port Air Operated Valve VTA. Indicate VO for manifold. Port size. Nil 02 1/4. Specifications Fluid. Option Description Bracket (With screw) Series VTA301 How to Order VTA 301 Indicate VO for manifold. Port size Without connection port (For manifold) 01 1/8 02 1/4 F N T Option B Rc G NPT NPTF Without bracket Foot bracket JIS Symbol Specifications

More information

Coolant Valve. Air Operated/External Pilot Solenoid

Coolant Valve. Air Operated/External Pilot Solenoid Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) lange type (3 to ) Low water hammer or details, refer to page

More information

3 Port Air Operated Valve

3 Port Air Operated Valve Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation

More information

Process Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control Process Valve: Port Valve For Compressed ir and ir-hydro Circuit Control Series VN Style VN -6 VN -8 8 VN - 3 8 VN - 5 VN -5 VN3-0 3 0 Note) This product cannot be used for water application. JIS Symbol

More information

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) type (3 to ) Low water hammer or details, refer to page 07. Large

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

More information

Flow characteristics Max. (1) b Standard Specifications. P Manual override.

Flow characteristics Max. (1) b Standard Specifications. P Manual override. Port Direct Operated Solenoid Valve Series 0 Metal Seal Model Number of positions (Single) (Double) ( position) JIS Symbol Model Port size Rc (Nominal size) 0-0 8 ( A) 0- ( 8A) 0-0 8 (0A) 0-0 8 ( A) 0-

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M. V3 Cover

More information

Rubber Seal VP300/500/700

Rubber Seal VP300/500/700 Port Pilot Operated Poppet Rubber Seal 00/500/700 High flow capacity Cv1.0 (00), Cv. (500), Cv.0 (700) Low power consumption: 1.8W(DC) Possible to use as either selector valve or divider valve Changeable

More information

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Soft Start-up Valve. AV2000/3000/4000/5000 Series Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off

More information

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot ubber seal ort ilot Solenoid Valve Series SYJ00 Specifications efer to www.smcworld.com for details of products compatible with overseas standards. Body ported Base mounted Fluid Operating pressure range

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR2 JIS Symbol type

More information

3 Port 3 Position Valve

3 Port 3 Position Valve Port Position Valve Pilot Solenoid ir Operated ohs Intermediate stopping of cylinders * up to ø15 is possible. Pilot solenoid Manifold ir operated * For VEX 4, 00 mm/s, horizontal movement Power consumption:

More information

Coolant Valve. VNC Series. Cylinder actuation by pilot air

Coolant Valve. VNC Series. Cylinder actuation by pilot air oolant VN Series ir Operated/xternal Pilot Solenoid [Option] ylinder actuation by pilot air Wide selection of port and variations Threaded type (6 to ) lange type (3 to 80) Low water hammer or details,

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S. High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure of 0.5MPa, subject to clean, dry air) 4 Port Direct

More information

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types Speed 2 Port Valve Series RoHS speed speed speed response response response 5 ms 9mm Width ±0.05 ms ±0.05 ms type VCH : : 5 ms * The response time is measured based on SMC test conditions. (Not guaranteed

More information

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type. Series -S00 ompact Direct Operated Port Solenoid Valve ontrol Valves ase mounted ody ported lean Series lean Series V S R oil voltage 24 VD VD VD VD VD Power consumption Pressure specification Flow rate

More information

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC)

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC) Port Solenoid Valve/Direct Poppet Rubber seal Series VK3000 Nl/min 147 Compact/Width 18 X Length 8 (mm) Low power consumption 4W DC (Standard) 2W DC (Energy saver) Standard copper free specification All

More information

Non-Contact Sensor for Workpiece Placement Verification

Non-Contact Sensor for Workpiece Placement Verification ir Catch Sensor Series 2 Non-Contact Sensor for Workpiece Placement Verification Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact

More information

Series VQZ1000/2000/3000 Single Unit

Series VQZ1000/2000/3000 Single Unit +- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body

More information

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal

More information

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high

More information

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A) ort Solenoid Valve ubber Seal Series SY00 Low power consumption: 0.W (Standard, Without light) (Current draw: m at V DC) Large flow capacity style:0.7w (Current draw: m at V DC) Body width: 0mm 7.8 Nl/min

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 044 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000 racket

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry TEX Compliant Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 44 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Rubber Seal Port Solenoid Valve Series Manifold Single Unit ase Mounted Manifold VV01 V100 ar base P.18 ody Ported P.10 ase Mounted P.10 VQD VKF VK VT VS Separable base ody Ported Manifold P.1 Stacking

More information

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),

More information

Series SYJ300/500/700

Series SYJ300/500/700 ort Solenoid Valve ubber Seal Series SYJ00/00/00 Low power consumption: 0.W (Without light) (Current draw: 1m at 4V DC) Completely interchangeable ilot exhaust with the previous series VJ00/00/00 and VZ00/00.

More information

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series VZS Series Variations Plug-in Type Base Mounted Type (With sub-plate) Non Plug-in Type Base Mounted Type (With sub-plate) Series Sonic conductance

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model 2 position 3 position

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3

More information

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold Port Solenoid Valve VV00 Series Highly Integrated Unit Manifold po ted - pera irect-o d station es on rt valv ally ividu Ind wired n be ve ca val d. adde ector Con-inn connection) lug (For p ø connection

More information

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Body Ported Base Mounted Series S000 S000 S000 S000 S000 S4000 S5000 Sonic conductance C [dm /s bar)] 4/ 5/(A/B R/R) Single Double.8.4

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and

More information

Series SYA3000/5000/7000

Series SYA3000/5000/7000 Port Air Operated Valve Series SYA000/000/7000 How to Order A, B port size Thread type Thread piping (Inch size) Nil Rc Symbol Port size Applicable series Symbol Port size Applicable series F G M SYA000

More information

1 1/4 (32A) to 2 (50A) added.

1 1/4 (32A) to 2 (50A) added. Coolant Valve 0.5 MPa.0 MPa.6 MPa RoHS /4 (3) to (50) added. Flow rate Cv (For 0.5 MPa specification) 3 4 5 0 0 30 Cv (kv) 40 5 million cycles or more Port size 70 6.5 (5.6) 3/8 (0), / (5).8 (0.) 3/4 (0)

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

Series SYA3000/5000/7000

Series SYA3000/5000/7000 Port Air Operated Valve Series SYA000/000/7000 How to Order A, B port size Thread type Thread piping (Inch size) - Rc Symbol Port size Applicable series Symbol Port size Applicable series F G SYA000 N

More information

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm 4 Port Direct Operated Poppet Solenoid Valve Series D1000 High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure

More information

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control Process Series Port For Compressed Air and Air-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Cylinder actuation by external air he balance poppet

More information

5 Port Solenoid Valve Plug Lead Type

5 Port Solenoid Valve Plug Lead Type 5 Port Solenoid alve Plug Lead Type Series Body Ported Flow rate characteristics For single/double solenoid C [dm 3 /(s bar)]: 0.6 Single Unit alve width: 7.4 mm Possible to drive cylinders: Up to ø32

More information

Series SYA3000/5000/7000

Series SYA3000/5000/7000 Port Air Operated Valve Series SYA000/000/7000 How to Order A, B port size Thread type Thread piping (Inch size) Nil Rc Symbol Port size Applicable series Symbol Port size Applicable series F G M SYA000

More information

Series SYA3000/5000/7000

Series SYA3000/5000/7000 1 Port Air Operated Valve Series SYA000/000/7000 Body ported Base mounted Base mounted How to Order A, B port size Thread type Thread piping (Inch size) Nil Rc Symbol Port size Applicable series Symbol

More information

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating / ort Solenoid Valve ubber Seal Series SYJ000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Specifications JIS Symbol port port (manifold) position

More information

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04 Three functions (pressure regulator, switching valve, and speed controller) are provided by a single valve. The conventional valve combination circuit has been condensed into a single valve. A large capacity

More information

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector

More information

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is. Port Solenoid Valve Series VQ 00 Unprecedented high speed, stable response, and extra-long service life. ON:.ms, OFF: ms, Dispension accuracy ±ms (With indicator light and surge voltage suppressor; supply

More information

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications Series -SQ00 Port Solenoid Valve Plug-in Unit [Option] How to Order Manifold Electrical entry F kit D-sub connector kit P kit SSQ 08 FD Kit type Flat ribbon cable connector kit J kit Flat ribbon cable

More information

4F0/1/2/3 Series. Min. working pressure MPa Refer to the individual specifications below to 60 Lubrication Not required (when lubricating,

4F0/1/2/3 Series. Min. working pressure MPa Refer to the individual specifications below to 60 Lubrication Not required (when lubricating, MNE0 M MN W L/ QV JIS symbol 5 port valve position single solenoid position double solenoid position all ports closed position //R connection position P// connection Common specifications Descriptions

More information

3 Port Air Operated Valve. SYJA300 Series. How to Order. Nil Without sub-plate. Type of actuation. Normally closed Normally open

3 Port Air Operated Valve. SYJA300 Series. How to Order. Nil Without sub-plate. Type of actuation. Normally closed Normally open 3 ort ir Operated Valve SYJ300 Series How to Order SYJ3 M3 Bracket Nil Without bracket F With bracket *The bracket is not mounted. *The bracket cannot be retrofitted later. SYJ3 Type of actuation Normally

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series 1 Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC Base Mounted Series VQZ00/00/00 VQZ00/00 / How to Order Valve Made to Order (For details, refer to page 9 and 4.) VQZ 5 5 M Series VQZ00 body width 5 mm VQZ00 body width 8 mm Type of actuation 4 N.C. N.O.

More information

Manifold Specifications

Manifold Specifications Series 00 Manifold Specifications Manifold Specifications Model Manifold type P(SUP)/R(EXH) Valve stations A port porting specifications Port size For internal pilot For external pilot Location Direction