Pilot Operated 2 Port Solenoid Valve for Dry Air

Size: px
Start display at page:

Download "Pilot Operated 2 Port Solenoid Valve for Dry Air"

Transcription

1 Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0 VQ LVM High frequency operation possible High speed response 7 ms or less (VQ0), 0 ms or less () (High speed response type without light/surge voltage suppressor at the supply pressure of 0.5 MPa) Long operating life Easy piping with One-touch Fittings Dusttight low jetproof enclosure (IP65) compliant in DIN terminal type. pplication: ir-blow, Blow-off of workpiece, etc. 53

2 Pilot Operated For Dry ir Port Solenoid Valve VQ0/30 Series Single Unit [Option] How to Order Valves VQ G C6 Series/ Orifice diameter Symbol 3 Series VQ0 Valve type N.C. (OUT) (IN) When the valve is closed, flow is blocked from port to port. However, if the pressure in port is higher than port, the valve will not be able to block the fluid and it will flow from port to port. Body type : Single unit M: For manifold Coil voltage 00 VC (50/60 Hz) 00 VC (50/60 Hz) 3 0 VC (50/60 Hz) 4 0 VC (50/60 Hz) 5 4 VDC 6 VDC Note ) 9 Other special voltage Note ) Please consult with SMC for special voltages. Note ) There is polarity for DC voltage (with power-saving circuit type). Electrical entry G: Grommet Manual override None Note) Slotted locking type B (tool required) Note) Only normally closed DIN terminal in-line type is applicable. Electricity circuit Symbol DC voltage Port size Symbol Port size C6 C8 C0 C With power-saving circuit (With surge voltage suppressor protection circuit) With power-saving circuit Z (With light/surge voltage suppressor protection circuit) Note) High speed response type H (Without energy-saving, light/surge voltage suppressor circuit) Note) H is available only for DC voltage and cannot be energized continuously. Made to Order Specifications Oil-free specifications VQ 3M Option : None F: With bracket L: Type L (VQ0 only) CE-compliant Q Note) If ordering both options, indicate LF. One-touch fitting for ø6 One-touch fitting for ø8 One-touch fitting for ø0 One-touch fitting for ø X(-Q) CE-compliant Made to Order specifications (Refer to the table below) VQ0 C voltage With full wave rectifier circuit (With surge voltage suppressor protection circuit) With full wave rectifier circuit (With light/surge voltage suppressor protection circuit) Please contact SMC for further specifications, delivery and price. Note) Please consult with SMC when using. Not available for manual operation. Y: DIN terminal YO: DIN terminal without connector Seal material fluororubber specifications VQ 3M Seal material fluororubber/oil-free specifications VQ 3 M Note) Not available for manual operation. X5(-Q) X3(-Q) B 54

3 Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Standard Specifications Symbol Construction w (OUT) (IN) N.C. e q VQ0 When the valve is closed, flow is blocked from port to port. However, if the pressure in port is higher than port, the valve will not be able to block the fluid and it will flow from port to port. Valve specifications Electric specifications Series Valve construction Fluid mbient and fluid temperature Lubrication Manual override Impact resistance/vibration resistance Enclosure Internal leakage cm 3 /min Exterior leakage cm 3 /min Mounting orientation Weight Coil rated voltage llowable voltage fluctuation Coil insulation type Power DC voltage (with power-saving circuit) consumption DC voltage (without power-saving circuit) (Current value) C r t y u Electrical entry VQ0 port poppet pilot operated Note ) ir Note ) 0 to 50 C Not required Note 3) Slotted locking type (tool required) 50/30 m/s Note 4) Note 5) Dustproof 5 or less 5 or less Unrestricted 46 g 80 g VDC, 4 VDC, 00 VC, 0 VC, 00 VC, 0 VC ±0% of rated voltage Class B or equivalent Inrush:.9 W, Holding: 0.6 W.9 W V Grommet, DIN terminal Note ) This product is for dry air. Use in clean air, and be sure that drain and oil content does not flow into the product. Note ) Use dry air to prevent condensation when operating at low temperatures. Note 3) Manual override is available only for DIN terminal type. Note 4) Vibration resistance: No malfunction occurred in a one-sweep test between 8.3 and 000 Hz. Test was performed at both energized and de-energized states to the axis and right angle directions of the main valve and armature (value at the initial state). Impact resistance: No malfunction resulted from the impact test using a drop impact tester. The test was performed on the axis and right angle directions of the main valve and armature for both energized and de-energized states (value at the initial state). Note 5) DIN terminal type: pplicable to dusttight and low jetproof (IP65). Characteristic Specifications Series VQ0 Port size ø6 ø8 ø0 ø Note ) Flow rate characteristics C [dm 3 /(s bar)] b Cv Min. operating pressure differential Note 4) 0.0 MPa Max. operating pressure 0.6 MPa 0.5 MPa Note 3) Note 3) Electricity circuit With power-saving circuit High speed response type With power-saving circuit High speed response type Note ) Response time ON OFF 0 ms or less 5 ms or less 7 ms or less 5 ms or less 5 ms or less 5 ms or less 0 ms or less 5 ms or less Note ) The flow rate characteristics of this product have variations. Note ) JIS B (Value of high response time is subject to change upon pressure, quality of air.) Note 3) It cannot be used when energized continuously. Note 4) If a restrictor (nozzle, etc.) is mounted on the outlet side piping, the pressure differential when ON is smaller. Be sure that the pressure differential does not drop below 0.0 MPa. dditionally, take great care when used for the ejector supply, etc. Component Parts No Description Solenoid coil Body Fixed armature rmature Return spring Poppet Diaphragm assembly Material Resin Stainless steel Stainless steel Stainless steel NBR H NBR, Resin VCH VDW SX0 VQ LVM 55 B

4 VQ0/30 Series Dimensions: VQ0 Series In-line Type: Grommet (G) VQ-G- - Mounting holes x ø3. through Bracket mounting holes x ø3. through Light Lead wire length pprox. 300 P port C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 Dotted line: Bracket mounting type (-F) 56

5 Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Dimensions: VQ0 Series Type L: Grommet (G) VQ-G- -L Light Lead wire length pprox. 300 VCH P port C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 VDW SX0 VQ LVM C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 x ø3. mounting hole Dotted line: Bracket mounting type (-LF) 57

6 VQ0/30 Series Dimensions: VQ0 Series In-line Type: DIN terminal (Y) VQ-Y- - Mounting hole x ø3. through Bracket mounting hole x ø3. through Manual override pplicable cable O.D. ø3.5 to ø7.0 mm P port C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 Dotted line: Bracket mounting type (-F) 58

7 Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Dimensions: Series In-line Type: Grommet (G) VQ3-G- - Mounting hole x ø4.3 through Bracket mounting hole x ø4.5 through Light Lead wire length pprox. 300 VCH VDW SX0 VQ LVM P port C0: One-touch fitting for ø0 C: One-touch fitting for ø C0: One-touch fitting for ø0 C: One-touch fitting for ø Dotted line: Bracket mounting type (-F) 59

8 VQ0/30 Series Dimensions: Series DIN terminal (Y) VQ3-Y- - Mounting hole x ø4.3 through Bracket mounting hole x ø4.5 through Manual override pplicable cable O.D. ø3.5 to ø7.0 mm P port C0: One-touch fitting for ø0 C: One-touch fitting for ø C0: One-touch fitting for ø0 C: One-touch fitting for ø Dotted line: Bracket mounting type (-F) 50

9 Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series How to Order Manifold VVQ 08 3 Series VQ0 Stations 0 station 0 0 stations Option D DO P port/thread type 00N 00T 00F CE-compliant Q CE-compliant Rc 3/8 NPT 3/8 NPTF 3/8 G 3/8 None DIN rail mounting DIN rail mounting (Without DIN rail) How to Order Manifold ssembly Enter the mounting valve and option part numbers under the manifold base part number. <Ordering Example> VVQ-05 (-Q) set Manifold part No. VQM-5G-C6 (-Q) 4 sets Valve part No. (Stations to 4) VQM-5G-C8 (-Q) set Valve part No. (Station 5) is the symbol for assembly. dd a in front of the part numbers for solenoid valves, etc., to be mounted. Stations 3 U side D side Enter together in order, counting from station on the D side. [Option] P How to Order Valves (For Manifold) Series/ Orifice diameter Symbol Series VQ0 3 G Y YO Valve Type N.C. (OUT) VQ M G C6 (IN) When the valve is closed, flow is blocked from port to port. However, if the pressure in port is higher than port, the valve will not be able to block the fluid and it will flow from port to port. Valve specifications M Manifold Electrical entry Grommet DIN terminal DIN terminal (without connector) Note ) Coil voltage 00 VC (50/60 Hz) 00 VC 0 VC 0 VC (50/60 Hz) 4 VDC VDC Other special voltage Note ) Please consult with SMC for special voltages. Note ) There is polarity for DC voltage (with power-saving circuit type). Electricity circuit Symbol Z H Note) Port size Symbol C6 C8 C0 C DC voltage With power-saving circuit (with surge voltage suppressor protection circuit) With power-saving circuit (with light/surge voltage suppressor protection circuit) High speed response type (without energy-saving, light/surge voltage suppressor circuit) Made to Order specifications Q (Refer to the table below) Port size One-touch fitting for ø6 One-touch fitting for ø8 One-touch fitting for ø0 One-touch fitting for ø VQ0 Manual override None B Note) Slotted locking type (tool required) Note) Only normally closed DIN terminal in-line type is applicable. Note) H is available only for DC voltage and cannot be energized continuously. CE-compliant CE-compliant C voltage With full wave rectifier circuit (with surge voltage suppressor protection circuit) With full wave rectifier circuit (with light/surge voltage suppressor protection circuit) VCH VDW SX0 VQ LVM Made to Order Specifications Please contact SMC for further specifications, delivery and price. Oil-free specifications VQ 3 M X (-Q) Note) Please consult with SMC when using. Not available for manual operation. Seal material fluororubber specifications VQ 3 M X5 (-Q) 5 B

10 VQ0/30 Series Dimensions Plug lead unit manifold (VVQ- ) Mounting hole x ø4.5 through L4 L3 L 5 35 L C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 P = x Rc 3/8 P port P DIN rail mounting 4 x M3 x L5 5.6 Dotted line: DIN rail mounting (-D) Dimensions L L L L3 L4 L5 n Formulas L = (n ) x L = L 0 L3 = L4 0.5 L5 = L. n: Station (Max. 0)

11 Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Dimensions Plug lead unit manifold (VVQ3- ) Mounting hole x ø4.5 through L4 L3 L 5 35 L C0: One-touch fitting for ø0 C: One-touch fitting for ø P = x Rc 3/8 P port DIN rail mounting 4 x M3 x VCH P VDW SX0 VQ LVM L5 5.6 Dotted line: DIN rail mounting (-D) Formulas L = (n ) x L = L 0 L3 = L4 0.5 L5 = L. Dimensions n: Station (Max. 0) L n L L L L L

12 VQ0/30 Series Single Unit Option Bracket assembly (with mounting screws) For fixing this solenoid valve. Type VQ0 Grommet in-line type VQ0 Grommet L type, DIN terminal type DIN terminal L type Bracket assembly XT835-3 XT XT XT837-3 (Mounting screws, pcs.) M3 x 45 M3 x 40 M3 x 35 M4 x 45 Manifold Option DIN rail XT00-DR- L.5 (Pitch) Suffix the number from DIN rail dimensions table below. Refer to the dimension drawing for each manifold for L dimension Each manifold can be mounted on a DIN rail. Order with the option symbol -D to specify DIN rail mounting type. The DIN rail is approximately 30 mm longer than the length of manifold. L dimension VQ0 series Stations No. L series Stations No L DIN rail mounting bracket VVQZ00-DB-5 This bracket is used for mounting the manifold on the DIN rail. DIN rail mounting bracket is attached on the manifold. set of DIN rail mounting brackets for manifold includes brackets. Blanking plate assembly (with O-ring and mounting screws) Mount a blank plate on valve manifold when a valve is disassembled for maintenance purposes, or when spare valve unit is supposed to be mounted in the future. Series VQ0 Blanking plate assembly XT XT (O-ring) OR H OR H (Mounting screws, pcs.) M3 x 6 M4 x 6 54

13 VQ0/30 Series Specific Product Precautions Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 7 to 9 for Port Solenoid Valve for Fluid Control Precautions. Warning Selection. ir quality This product is for dry air. Drain, oil, etc. in the air may result in faulty operation. Use clean (dry) air.. Pressure differential If a restrictor (nozzle, etc.) is mounted on the outlet side, the outlet side pressure differential at the inlet side is smaller. Be sure the pressure differential when ON does not drop below 0.0 MPa. Manual Override Warning Regardless of electric signals to the solenoid valve, the manual override is used for switching the main valve. (DIN terminal only.) Push the manual override Slotted locking type (tool required) button with a small flat head screwdriver until it stops. Turn it in the counterclockwise direction at ø to lock the manual. Turn it right to release. LED PUSH Timer circuit TURN LOCK Connection and Electrical Circuit Caution Black ( ) DC Blue (00 VC) Red (00 VC) Gray (Other C) Red (+) DC Blue (00 VC) Red (00 VC) Gray (Other C) Grommet lead wire WG, Insulator O.D..6 mm With DC voltage power-saving circuit (with polarity) Lead wire color DIN connector Red (+) SOL. Connection and Electrical Circuit Caution Power wave form of power-saving type (Rated voltage at 4 VDC) pplied voltage 4 V C circuit Lead wire color Blue (00 VC) Red (00 VC) Gray (Other C) Blue (00 VC) Red (00 VC) Gray (Other C) 0 V 0 to 0 ms.9 W 0.6 W 0 W DIN connector Caution Power-saving Valve Mounting When mounting the valve, secure with brackets. When mounting it directly, tighten the mounting screws with the appropriate torque (0.7 to 0.8 N m). Mounting screw Tightening torque 0.7 to 0.8 N m LED When Energizing Continuously for Long Period of Time SOL. Caution When energizing continuously, choose the option of an energysaving circuit specifications. High speed response type (with no energy-saving circuit) cannot be energized continuously. VCH VDW SX0 VQ LVM Black ( ) i i i: Inrush current, i: Holding current DC (with power-saving circuit) specifications is designed to reduce the power consumption at holding to achieve powersaving by circuit shown above. Refer to below power wave form. 55

14 VQ0/30 Series Specific Product Precautions Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 7 to 9 for Port Solenoid Valve for Fluid Control Precautions. How to Wire DIN Terminal Caution ISO#: Based on DIN 43650C (Pin gap 8 mm) Connection. Loosen the tightening screw and pull the connector off of the solenoid valve.. fter removing the tightening screw, divide the terminal block and housing by prying open the slot area of the lower part of the terminal block open with a screwdriver. 3. Loosen the terminal screws of the block and insert stripped lead wires in accordance with the wiring diagram. Secure each wire by re-tightening the terminal screw (In the case of terminal : (+), : (-) DC) 4. Tighten the ground nut to secure the cable wire. Change of electrical entry Wire entry can be changed by mounting the housing in either direction (four directions at every 90 ) after dividing the terminal block and the housing. For the indicator lighted type, be careful not to damage the light with the lead wire of the cable. Precautions Insert a connector straight or pull it out straight, using caution it does not be tilted. pplicable cable Cord O.D.: ø3.5 to ø7 (Reference) 0.5 mm -core and 3-core wire equivalent to JIS C Ground nut Tightening torque.65 to.5 N m Washer Grommet (Rubber) (Voltage symbol) Refer to the following table Tightening torque 0. to 0.5 N m Terminal screw (3 positions) Tightening screw Tightening torque 0.3 to 0.4 N m Housing (Position for light mounting) Terminal block Shaved part DIN Terminal Part No. (Based on DIN) Without indicator light SY With Indicator Light Rated voltage Voltage symbol Part no. 4 VDC VDC 00 VC 00 VC 0 VC 0 VC 4 V V 00 V 00 V 0 V 0 V SY SY SY SY SY SY DIN Terminal Circuit with Indicator Light C circuit How to Wire DIN Terminal NL R NL: Neon light R: Resistor Manifold How to Mount/Remove from DIN Rail Caution Removing procedure. Loosen the clamp screw on the side of both ends of the manifold.. Lift the side of the manifold off the DIN rail and slide it in the direction of the arrow. Mounting procedure. Hook the mounting hook on the B side of the manifold base to the DIN rail.. Press down side and mount the end plate on the DIN rail. Tighten the clamp screw on side B of the end plate. (Tightening torque: 0.3 to 0.4 N m). Caution Valve Mounting DC circuit LED R LED: Light emitting diode R: Resistor fter confirming the gasket is correctly placed under the valve, tighten the mounting screws with the appropriate torque (0.7 to 0.8 N m). Manifold mounting screw B Manifold mounting screw 56

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to

More information

3 Port Solenoid Valve

3 Port Solenoid Valve 3 ort Solenoid Valve Series VKF300 ubber Seal Direct Operated oppet Type Compact yet provides a large flow capacity Body width 8 mm vailable in vacuum applications ( 0. ka) Can be used in vacuum/release

More information

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series

More information

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position

More information

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S. High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure of 0.5MPa, subject to clean, dry air) 4 Port Direct

More information

Series VQZ1000/2000/3000 Single Unit

Series VQZ1000/2000/3000 Single Unit +- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M. V3 Cover

More information

Non-Contact Sensor for Workpiece Placement Verification

Non-Contact Sensor for Workpiece Placement Verification ir Catch Sensor Series 2 Non-Contact Sensor for Workpiece Placement Verification Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted

More information

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm 4 Port Direct Operated Poppet Solenoid Valve Series D1000 High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure

More information

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is. Port Solenoid Valve Series VQ 00 Unprecedented high speed, stable response, and extra-long service life. ON:.ms, OFF: ms, Dispension accuracy ±ms (With indicator light and surge voltage suppressor; supply

More information

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot 3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in

More information

0.35 W (Without light)

0.35 W (Without light) Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:

More information

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector

More information

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type. Series -S00 ompact Direct Operated Port Solenoid Valve ontrol Valves ase mounted ody ported lean Series lean Series V S R oil voltage 24 VD VD VD VD VD Power consumption Pressure specification Flow rate

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

VQ1000. How to Order Manifold. Kit type

VQ1000. How to Order Manifold. Kit type - - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold

More information

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),

More information

Vacuum / Release Unit

Vacuum / Release Unit Rubber Seal Vacuum / Release Unit Series VQD1000-V Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area Smooth detachment of a work piece without over-blow

More information

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types Speed 2 Port Valve Series RoHS speed speed speed response response response 5 ms 9mm Width ±0.05 ms ±0.05 ms type VCH : : 5 ms * The response time is measured based on SMC test conditions. (Not guaranteed

More information

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air Compact Direct Operated / Port Solenoid Valve for Water and Air 0/0/0: Port, 00/00: Port 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to

More information

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

More information

Series SV1000/2000/3000/4000

Series SV1000/2000/3000/4000 Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double

More information

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000

More information

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Vacuum / Release Unit Series VQD1000-V Rubber Seal Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area [Option] Smooth detachment of a work piece without

More information

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000) 5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry

More information

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A) ort Solenoid Valve ubber Seal Series SY00 Low power consumption: 0.W (Standard, Without light) (Current draw: m at V DC) Large flow capacity style:0.7w (Current draw: m at V DC) Body width: 0mm 7.8 Nl/min

More information

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot ubber seal ort ilot Solenoid Valve Series SYJ00 Specifications efer to www.smcworld.com for details of products compatible with overseas standards. Body ported Base mounted Fluid Operating pressure range

More information

Series SYJ300/500/700

Series SYJ300/500/700 ort Solenoid Valve ubber Seal Series SYJ00/00/00 Low power consumption: 0.W (Without light) (Current draw: 1m at 4V DC) Completely interchangeable ilot exhaust with the previous series VJ00/00/00 and VZ00/00.

More information

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal

More information

Example. U side. Stations SY5000

Example. U side. Stations SY5000 45 Type 5 ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN ail Mounted/Individual Wiring Series SY3000/5000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 3 45 05 U C6 Example

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC Base Mounted Series VQZ00/00/00 VQZ00/00 / How to Order Valve Made to Order (For details, refer to page 9 and 4.) VQZ 5 5 M Series VQZ00 body width 5 mm VQZ00 body width 8 mm Type of actuation 4 N.C. N.O.

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion

More information

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Soft Start-up Valve. AV2000/3000/4000/5000 Series Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Series VQ Rubber Seal Space-saving profile Clean space saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

Rubber Seal VP300/500/700

Rubber Seal VP300/500/700 Port Pilot Operated Poppet Rubber Seal 00/500/700 High flow capacity Cv1.0 (00), Cv. (500), Cv.0 (700) Low power consumption: 1.8W(DC) Possible to use as either selector valve or divider valve Changeable

More information

High Pressure Coolant Valve

High Pressure Coolant Valve High Pressure Coolant Valve Series.5 MPa, 7.0 MPa Corresponding to high speed grinding and long drilling processes Coolant valve for high pressure coolant liquid (up to.5 MPa or 7.0 MPa) that is ideal

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Series 000 Compact and lightweight: 3 mm width Compact yet provides

More information

1 1/4 (32A) to 2 (50A) added.

1 1/4 (32A) to 2 (50A) added. Coolant Valve 0.5 MPa.0 MPa.6 MPa RoHS /4 (3) to (50) added. Flow rate Cv (For 0.5 MPa specification) 3 4 5 0 0 30 Cv (kv) 40 5 million cycles or more Port size 70 6.5 (5.6) 3/8 (0), / (5).8 (0.) 3/4 (0)

More information

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC)

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC) Port Solenoid Valve/Direct Poppet Rubber seal Series VK3000 Nl/min 147 Compact/Width 18 X Length 8 (mm) Low power consumption 4W DC (Standard) 2W DC (Energy saver) Standard copper free specification All

More information

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications Series -SQ00 Port Solenoid Valve Plug-in Unit [Option] How to Order Manifold Electrical entry F kit D-sub connector kit P kit SSQ 08 FD Kit type Flat ribbon cable connector kit J kit Flat ribbon cable

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and

More information

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Body Ported Base Mounted Series S000 S000 S000 S000 S000 S4000 S5000 Sonic conductance C [dm /s bar)] 4/ 5/(A/B R/R) Single Double.8.4

More information

Exclusively for air pressure system and air-hydro circuit control

Exclusively for air pressure system and air-hydro circuit control Process Valve Series Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type20P 5 Port Solenoid Valve ody Ported Manifold ar Stock Type/Flat Ribbon Cable Series SY3000/5000/7000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 5 20P 05 Manifold series 3 SY3000

More information

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum 3 Port Direct Operated Poppet Rubber Seal Series 307 Large Flow Capacity, yet Compact Size. Dimensions (W X H X D) 30 X 54.5 X 33 307 Nl/min 206.02 or more, 1/4 Low Power Consumption /VO307 4.8W DC/Standard

More information

3 Port 3 Position Valve

3 Port 3 Position Valve Port Position Valve Pilot Solenoid ir Operated ohs Intermediate stopping of cylinders * up to ø15 is possible. Pilot solenoid Manifold ir operated * For VEX 4, 00 mm/s, horizontal movement Power consumption:

More information

How to Order Manifold. Kit type L8 B4 B6 B8 LM

How to Order Manifold. Kit type L8 B4 B6 B8 LM 0 Stations station VVQ Series VQ000 The maximum and minimum number of are varied depending on. (Refer to the table below.) Series VQ000 ase Mounted Plug-in Unit Manifold Plug-in unit 08 C Cylinder port

More information

1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption

1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption Port Solenoid Valve Direct Operated Poppet Type Power consumption Vacuum applications New [Option] RoHS 4 Standard wtype (Existing product: 4.8 W) 0. kpa Energy-saving type.8 w (Existing product: W) A

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR2 JIS Symbol type

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

Compact Proportional Solenoid Valve

Compact Proportional Solenoid Valve Compact Proportional Solenoid Valve Series Repeatability: % or less Hysteresis:1% or less Fluid Flow rate control range Note) Series Air, Inert gas to L/min to L/min Note) Varies depending on the model.

More information

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control Process Valve Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external pilot

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 MPa Pilot Operated /3 Port Solenoid Valve & Check Valve VCH Series VCH4/4: Port VCH40: 3 Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve [Option] VCH40 Series Stable responsiveness Response

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

Indicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A

Indicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A 1 3 Port Air Operated Valve Series VTA301 JIS Symbol VTA 301 Indicate VO for manifold. Port size Specifications How to Order Without connection port (For manifold) 01 1/8 02 1/4 Option Fluid Air Operating

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000 D-sub Connector J Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000//000 Number of connectors: pins MIL-C-08 Conforming to JIS-X-0 --6 For details

More information

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles ort Solenoid Valve: ase Mounted Metal Seal/Rubber Seal Series Space and capacity saving ilot valve is gathered at one side. Space saving design which does not have any protrusions. Space saving Capacity

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating / ort Solenoid Valve ubber Seal Series SYJ000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Specifications JIS Symbol port port (manifold) position

More information

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) type (3 to ) Low water hammer or details, refer to page 07. Large

More information

2 Port Solenoid Valve For Dust Collector

2 Port Solenoid Valve For Dust Collector The VX* series will be revised shortly. 2 Port Solenoid Valve For Dust Collector Series 2 port solenoid valve for dust collector Series In this L-shaped 2 port valve, the bag filter is cleaned by high

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Rubber Seal Series VQ Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

Coolant Valve. Air Operated/External Pilot Solenoid

Coolant Valve. Air Operated/External Pilot Solenoid Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) lange type (3 to ) Low water hammer or details, refer to page

More information

Series SYA3000/5000/7000

Series SYA3000/5000/7000 Port Air Operated Valve Series SYA000/000/7000 How to Order A, B port size Thread type Thread piping (Inch size) - Rc Symbol Port size Applicable series Symbol Port size Applicable series F G SYA000 N

More information

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle. Multistage Ejector 112/212 Series Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Port Solenoid Valve Metal Seal Rubber Seal Series Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve ubber Seal / ort Solenoid Valve Series 000 / 000 / 000 [Option] SJ SY SV SZ V S000 VQ VQ VQ VQC VQZ SQ VFS VF VQ Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread

More information

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308 Cable ppendix Cable ppendix Multi-way cables The multi-pole connector cables used on SMC valves are common across several ranges. Cables are available in accordance with the MIL standard C-08 and also

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 044 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000 racket

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model 2 position 3 position

More information

3 Port Air Operated Valve

3 Port Air Operated Valve Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type1P Type2P 5 Port Solenoid Valve ase Mounted Manifold ar Stock Type/Flat Ribbon Cable Series /5000/000 How to Order Manifold Type 1P/Compact style SS5Y 5 1P 05 C8 Manifold series 3 5, port size Thread

More information

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series VZS Series Variations Plug-in Type Base Mounted Type (With sub-plate) Non Plug-in Type Base Mounted Type (With sub-plate) Series Sonic conductance

More information