Series VQZ1000/2000/3000 Single Unit

Size: px
Start display at page:

Download "Series VQZ1000/2000/3000 Single Unit"

Transcription

1 +- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body width 8 mm position single () () () () position closed center Type of actuation Note) 8 position pressure center position double port for mixture mounting (N.C.) (R)()(R) ()() (R)()(R) position exhaust center ()() ()() (R)()(R) (R)()(R) (R)()(R) ()() (R)()(R) Note) There is no position pressure center for the metal seal type of the VQZ series. () (R) () (R) () port for mixture mounting (N.O.) () ody type ase mounted M I compliant Nil W Note) Compliant Note) VQZ/ DIN terminal rubber seal only (except external pilot). For details on I enclosure, refer to page. Nil: Non-locking push type (Tool required) +- : Locking type (Tool required) ort size Symbol ort size VQZ VQZ VQZ Nil Without sub-plate Rc /8 Rc / Rc /8 Note) For inch sizes, refer to page. Electrical entry G: Grommet (DC specification) L: L-type plug connector with lead wire With light/surge voltage suppressor LO: L-type plug connector without connector With light/surge voltage suppressor M: M-type plug connector with lead wire With light/surge voltage suppressor CE compliant Nil Q CE marked Note) C-type models that are CE compliant have DIN terminals only. MO: M-type plug connector without connector With light/surge voltage suppressor Seal type Function Symbol Specifications DC C Nil Standard (. W) High speed response type (. W) Note ) K Note ) High pressure type ( type only) (. W) R Note, ) External pilot type R Note, ) High speed response/external (. W) pilot type KR Note, ) High pressure/external pilot type ( type only) (. W) Note ) Note ) Option Note ) For details on external pilot type, refer to page. Note ) For C specification power consumption, refer to page. Caution Use standard (DC) specification for continuous duty Note ) Note ) Note Y: DIN ) YO: DIN YZ: DIN YOS: DIN Note ) Note ) YS: DIN terminal terminal terminal terminal without connector (DC speci- terminal without connector (DC specificationfication) Coil voltage VDC With light/surge voltage suppressor Note ) pplicable to the VQZ/ for DIN terminal type. For C voltage valves there is no S option. It is already built-in to the rectifier circuit. Note ) Standard lead wire length: mm With surge voltage suppressor VDC With surge voltage suppressor VC (/ Hz) VC (/ Hz) VC [ VC] (/ Hz) VC [ VC] (/ Hz) VDC VDC Note) For sub-plate part no., refer to page 7. Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C 8-7-Main Office: () 88--Outside Local rea: (8) 8--

2 ase Mounted Series VQZ// Options High speed response type High pressure type ( type only) External pilot type For details on external pilot type, refer to page. Symbol X X X Series VQZ Made to Order (For details, refer to page 7.) Description ilot valve common exhaust Main valve fluoro-rubber ll fluoro-rubber Flow Characteristics position position position Configuration VQZ Closed center position Exhaust center ressure center position Single Double Closed center Exhaust center ressure center Single Double Single Double VQZ Closed center position Exhaust center ressure center Model Specifications Type Fluid Max. operating pressure (Ma) Min. operating position pressure (Ma) position mbient and fluid temperature ( C) Max. operating frequency (Hz) ilot exhaust method Lubrication VQZ VQZ VQZ VQZ VQZ VQZ VQZ VQZ VQZ VQZ VQZ VQZ VQZ VQZ VQZ VQZ VQZ VQZ VQZ VQZ VQZ VQZ VQZ VQZ VQZ VQZ VQZ VQZ VQZ Single Double position single, double position Mounting orientation Impact/Vibration resistance (m/s ) Note ) Enclosure ased on IEC Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and deenergized states every once for each condition. (Value in the initial state) Vibration resistance: No malfunction occurred in one sweep test between and Hz. Test was performed to axis and right angle directions of the main valve and armature when pilot signal is ON and OFF. (Value in the initial state) Note ) When I compliant DIN terminals are selected: VQZ - Y W- - Solenoid Specifications Electrical entry Coil rated voltage DC (V) C / Hz llowable voltage fluctuation ower consumption (W) pparent power (V) Surge voltage suppressor Indicator light Flow characteristics / ( /) / / (/ E/E) C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv W 7 or less 7 or less or less or less or less or less or less or less or less 8 or less or less or less or less 8 or less or less 8 or less or less 8 or less or less or less or less or less or less or less or less or less or less or less or less Note ) ased on JIS 87-8 (Supply pressure:. Ma; with light/surge voltage suppressor: clean air) Response time values will change depending on pressure and air quality. The values at the time of ON are given for double types. Note ) Weight without sub-plate DC C Standard High speed response, high pressure V V [V] V V [V] ir, Inert gas.7 (High pressure type:.).7.. VQZ, position only... to (No freezing) Non-locking push type, Locking type (Tool required) Individual exhaust Not required Free Single: Free Double, position: Main valve must be horizontal. / Dustproof (DIN terminal: I Note ) ) Grommet (G) L-type plug connector (L) In common between VC and VC, and between VC and VC. For VC and VC, the allowable voltage is % to +% of rated voltage. or less or less or less or less or less or less or less or less or less or less or less or less or less or less or less or less or less or less or less 7 or less or less or less or less or less or less or less or less or less or less M-type plug connector (M) DIN terminal (Y) G, L, M Y,,,, ±% of rated voltage. [(With light:. (DIN terminal with light:.)]. [(With light:. (DIN terminal with light:.)].78 (With light:.8).8 (With light:.8) [. (With light:.7)].8 (With light:.). (With light:.) [. (With light:.)].78 (With light:.87).8 (With light:.87) [. (With light:.7)]. (With light:.).7 (With light:.) [. (With light:.)] Varistor LED (Neon light when C with DIN terminal) Response time (ms) Note ) High pressure:. W or less or less or less or less 8 or less or less or less or less or less or less or less or less or less or less Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C 8-7-Main Office: () 88--Outside Local rea: (8) 8-- Standard: High speed response:. W C or less or less or less or less or less 7 or less or less 7 or less 7 or less or less or less or less or less or less 7 or less or less 7 or less or less 7 or less or less 7 or less or less or less or less or less or less or less or less or less Note ) Mass (g) SJ SY SV SYJ SZ V S7 VQ VQ VQ VQC VQZ SQ VFS VFR VQ7

3 Series VQZ// Construction: VQZ// type type position single () () position single () () (R) () (R) (R) () (R) position double () () position double () () (R) () (R) (R) () (R) position closed center () () position exhaust center () () position pressure center () () position closed center () () position exhaust center () () position pressure center () () (R) () (R) (R) () (R) (R) () (R) (R) () (R) (R) () (R) (R) () (R) Note) Except metal seal type of the VQZ. Component arts No. Description ody Spool, Sleeve Spool valve iston ilot valve assembly Material luminum die-casted Stainless steel luminum/hnr Resin Note) For How to Order ilot Valve ssembly, refer to page 7. Note Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C 8-7-Main Office: () 88--Outside Local rea: (8) 8--

4 ase Mounted Series VQZ// Dimensions: VQZ osition Single/ ort for Mixture Mounting Grommet (G): VQZ 8 (R)- G -. /8 [(), () port] SJ SY.8.. X pprox. M x.8 (External pilot port) <External pilot only> L-type plug connector (L): VQZ 8 (R)- L - 7. E port 8.8 ().8 () R... R 7. x ø.. /8 [(), (R), (R) port]. Y. M x.8 (Not used) M-type plug connector (M): VQZ 8 (R)- M - SV SYJ SZ V S7 VQ VQ VQ VQC VQZ SQ VFS VFR VQ7 pprox..8 [7] ().8 () pprox. 7. [8.8] () 7. [.] R R 8. [.] R R 78. [8.8] ().8 () 8.8 [7] () [ ]: C [ ]: C Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C 8-7-Main Office: () 88--Outside Local rea: (8) 8--

5 Series VQZ// Dimensions: VQZ osition Double Grommet (G): VQZ (R)- G -. /8 [(), () port] pprox.. x ø...8. X 7. x E port R R Y.. M x.8 (External pilot port) <External pilot only>.. 7. /8 [(), (R), (R) port]. M x.8 (Not used) L-type plug connector (L): VQZ (R)- L - M-type plug connector (M): VQZ (R)- M - pprox.. [.] pprox.. [] [.] R R 8. [.] R R [ ]: C [ ]: C Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C 8-7-Main Office: () 88--Outside Local rea: (8) 8--

6 ase Mounted Series VQZ// Dimensions: VQZ osition Closed Center/Exhaust Center/ressure Center (Except metal seal type) Grommet (G): VQZ (R)- G -. /8 [(), () port].8. SJ SY X pprox.. M x.8 (External pilot port) <External pilot only> x E port L-type plug connector (L): VQZ (R)- L - R.... R. x ø /8 [(), (R), (R) port]. Y. M x.8 (Not used) M-type plug connector (M): VQZ (R)- M - SV SYJ SZ V S7 VQ VQ VQ VQC VQZ SQ VFS VFR VQ7 pprox..8 [8.]. [7.] pprox.. [8.].8. [7.]. 7. [.] R R 8. [.] R R [ ]: C [ ]: C Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C 8-7-Main Office: () 88--Outside Local rea: (8)

7 Series VQZ// Dimensions: VQZ osition Single/ ort for Mixture Mounting Grommet (G): VQZ 8 (R)- G - 8 /8, / [(), () port] pprox x ø. R R.. X.8 E port Y. M x.8 (External pilot port) <External pilot only> /8, / [(), (R), (R) port]. M x.8 (Not used) L-type plug connector (L): VQZ 8 (R)- L - DIN terminal (Y): VQZ 8 (R)- Y - pprox.. [.7].8 [.8] Max.. pplicable cable O.D. ø. to ø7 g7 [ ]: C M-type plug connector (M): VQZ 8 (R)- M - pprox. 8.7 [8.] [8.] 8 [ ]: C [ ]: C Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C 8-7-Main Office: () 88--Outside Local rea: (8) 8--

8 ase Mounted Series VQZ// Dimensions: VQZ osition Double Grommet (G): VQZ (R)- G - 8 /8, / [(), () port].. X pprox..8 M x.8 (External pilot port) <External pilot only> x E port L-type plug connector (L): VQZ (R)- L - pprox..8 [.8] R R 8 8 Max. pplicable cable O.D. ø. to ø7 x ø. /8, / [(), (R), (R) port] g7. Y.8 M x.8 (Not used) pprox. 7. [.8] [8.] 7 [.] [ ]: C DIN terminal (Y): VQZ (R)- Y - SJ SY SV SYJ SZ V S7 VQ VQ VQ VQC VQZ SQ VFS VFR VQ7 M-type plug connector (M): VQZ (R)- M - [ ]: C Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C 8-7-Main Office: () 88--Outside Local rea: (8) 8--

9 Series VQZ// Dimensions: VQZ osition Closed Center/Exhaust Center/ressure Center Grommet (G): VQZ (R)- G - 8 /8, / [(), () port] x E port.8 Y /8, / [(), (R), (R) port]. M x.8 (Not used) Max..8 pplicable cable O.D. ø. to ø7 g7 8. pprox.. [.8] [.] [8.] 8 x ø. pprox. R R X. M x.8 (External pilot port) <External pilot only> L-type plug connector (L): VQZ (R)- L - DIN terminal (Y): VQZ (R)- Y - pprox. [.] 8. [.7].8 [.8] [ ]: C M-type plug connector (M): VQZ (R)- M - [ ]: C Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C 8-7-Main Office: () 88--Outside Local rea: (8) 8--

10 ase Mounted Series VQZ// Dimensions: VQZ osition Single/ ort for Mixture Mounting Grommet (G): VQZ 8 (R)- G - (8) /, /8 [(), () port]. pprox. 7 []. Max. pplicable cable O.D. ø. to ø7 g7. 7. [7.] [7.]. ( ): VQZ - G - X pprox. [7.] 7 M x.8 (External pilot port) <External pilot only> E port L-type plug connector (L): VQZ 8 (R)- L - [ ]: C M-type plug connector (M): VQZ 8 (R)- M - R. 7 R (8) (8). x ø..... /, /8 [(), (R), (R) port] Y DIN terminal (Y): VQZ 8 (R)- Y -. M x.8 (Not used) SJ SY SV SYJ SZ V S7 VQ VQ VQ VQC VQZ SQ VFS VFR VQ7 pprox. [ ]: C Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C 8-7-Main Office: () 88--Outside Local rea: (8) 8--

11 Series VQZ// Dimensions: VQZ osition Double Grommet (G): VQZ (R)- G - (8) /, /8 [(), () port].. 7. pprox. 7. x ø. R R 7.8 X x E port.. Y. M x.8 (External pilot port) <External pilot only> (8) (8). /, /8 [(), (R), (R) port] M x.8 (Not used) ( ): VQZ - G - L-type plug connector (L): VQZ (R)- L - DIN terminal (Y): VQZ (R)- Y - pprox..8 [.] 7 [] Max.. [ ]: C pplicable cable O.D. ø. to ø7 g7 7.8 M-type plug connector (M): VQZ (R)- M - 8. [7.] pprox. 7. [.] [ ]: C Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C 8-7-Main Office: () 88--Outside Local rea: (8) 8--

12 ase Mounted Series VQZ// Dimensions: VQZ osition Closed Center/Exhaust Center/ressure Center Grommet (G): VQZ (R)- G - (8) /, /8 [(), () port]... X pprox. M x.8 (External pilot port) <External pilot only> x E port L-type plug connector (L): VQZ (R)- L - pprox. 7 []. [.7] 8. [.] [ ]: C R R....7 (8) (8) Max. pplicable cable O.D. ø. to ø7 x ø /, /8 [(), (R), (R) port] DIN terminal (Y): VQZ (R)- Y - g7.. Y. M x.8 (Not used) ( ): VQZ - G -..8 SJ SY SV SYJ SZ V S7 VQ VQ VQ VQC VQZ SQ VFS VFR VQ7 M-type plug connector (M): VQZ (R)- M -.7 [.] 8. [7.] pprox. 8.. [.] [ ]: C Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C 8-7-Main Office: () 88--Outside Local rea: (8) 8--

13 ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Manifold Connector Kit [Option] How to Order Manifold Made to Order (For details, refer to page 7.) Note) 8 Symbol C C C C8 C M CM Note ) Note) There is no position pressure center for the metal seal type of the VQZ series. VVQZ 8 C C N Series VQZ VQZ VQZ Stations stations Manifold type ase mounted stations ort size [(), () port] ort size VQZ VQZ VQZ ø. one-touch fitting ø one-touch fitting ø one-touch fitting ø8 one-touch fitting ø one-touch fitting M thread Rc /8 Rc / Mixture of port sizes Note ) Specify port mixture/with port plug by the manifold specification sheet. ort mixture and port plug are available only for one-touch fitting type. Note ) For inch size one-touch fittings, refer to page. Kit type C Connector How to Order Valve Option Nil D D Note ) VQZ M Series VQZ body width mm VQZ body width mm VQZ body width 8 mm Type of actuation position single position double position closed center position exhaust center position pressure center port for mixture mounting N.C. port for mixture mounting N.O. Caution ody type Mase mounted Seal type Function Symbol Specifications DC C Nil Standard High speed response type (. W) (. W) Note ) K Note ) High pressure type ( type only) (. W) R Note, ) External pilot type R Note, ) High speed response/ (. W) External pilot type KR Note, ) High pressure/external pilot type ( type only) (. W) Note ) Note ) Option Note ) For details on external pilot type, refer to page. Note ) For C specification power consumption, refer to page. Use standard (DC) specification for continuous duty. N R Note ) CE compliant Nil Q CE marked None DIN rail mounting (With standard DIN rail length) DIN rail mounting (Without DIN rail) Name plate (Except VQZ) External pilot type Note ) Order DIN rail separately. For DIN rail part no., refer to page. Note ) For details on options and external pilot type, refer to page. Note ) When two or more symbols are specified, indicate them alphabetically. Nil Non-locking push type (Tool required) Locking type (Tool required) Electrical entry Coil voltage VC (/ Hz) VC (/ Hz) VC [ VC] (/ Hz) VC [ VC] (/ Hz) VDC VDC CE compliant Nil Q CE marked Note) C-type models that are CE compliant have DIN terminals only. Light/surge Symbol Electrical entry voltage suppressor G Grommet (DC specification) None L L-type plug connector with lead wire LO L-type plug connector without connector Yes M M-type plug connector with lead wire MO M-type plug connector without connector None YZ Note ) DIN terminal Yes YS Note ) DIN terminal (DC specification) Yes YOS Note ) DIN terminal without connector (DC specification) (Without light) Note ) pplicable to the VQZ/. For C voltage valves there is no S option. It is already built-in to the rectifier circuit. Note ) Standard lead wire length: mm Y Note ) DIN terminal YO Note ) DIN terminal without connector I compliant Nil W Note) Compliant Note) VQZ/ DIN terminal rubber seal only (except external pilot). For details on I enclosure, refer to page. Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C 8-7-Main Office: () 88--Outside Local rea: (8) 8--

14 ase Mounted Series VQZ// Manifold Specifications Series ase model iping direction iping specifications ort size (), /(R) (), () pplicable solenoid valve pplicable stations Note) Manifold base mass (g) Example D side U side Stations VQZ-L VQZ-L VQZ-L VQZ VQZ VQZ VVQZ- VVQZ- VVQZ- Note) Weight without sub-plate. How to Order Manifold ssembly (Example) Side Side Side VVQZ-CC VVQZ-- VQZ-L VQZ-L VQZ-L Rc/8 Rc/ () port Rc /8 /(R) port Rc / C (for ø.) C (for ø) C (for ø) M (M thread) C (for ø) C (for ø) C8 (for ø8) Rc /8 C (for ø) C8 (for ø8) C (for ø) Rc / VQZ VQZ VQZ VQZ VQZ VQZ to stations to stations to stations set (C kit -station manifold base part no.) set (lanking plate assembly part no.) set (Single type part no.) sets (Double type part no.) set ( position type part no.) The asterisk denotes the symbol for assembly. refix it to the part nos. of the solenoid valve, etc. Enter in order starting from the first station on the D side. stations: ddition per station: 7 stations: ddition per station: stations: 8 ddition per station: dd the valve and option part number under the manifold base part number. When entry of part numbers becomes complicated, indicate by the manifold specification sheet. SJ SY SV SYJ SZ V S7 VQ VQ VQ VQC VQZ SQ VFS VFR VQ7 VVQZ-- C: One-touch fitting for ø Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C 8-7-Main Office: () 88--Outside Local rea: (8) 8--

15 pprox. L L.7. E port X Series VQZ// Dimensions: VQZ VVQZ- Stations ort size C Grommet (G) D side (itch) =. U side (DIN rail clamp thread) (DIN rail). R R R R (8) (.) (.) ()... (.).8 C:. N7: 7.7 x ø. L L (Rail mounting hole pitch:.) L () (.) /8 [(), (R), (R) port] 8. (). (7.)... (Station ). (Station n) (itch) =. M x.8 [(), () port] One-touch fitting [(), () port] pplicable tubing O.D.: ø., ø/8" ø, ø/" ø, ø/". [8.]. [].7 [.] 8..8 R R M x.8 (External pilot port) (itch) =. External pilot M The dashed lines indicate the DIN rail mounting [-D]. L-type plug connector (L) M-type plug connector (M) pprox..7 [.7] pprox. 7 [7]. [.] The dashed lines indicate the DIN rail mounting [-D]. Unless otherwise indicated, dimensions are the same as Gormmet (G). [ ]: C.8 [8.]. [.]. [.]. [8.]. [] The dashed lines indicate the DIN rail mounting [-D]. Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Dimensions L n L L L L L Formula: L =.n +. L =.n + 7. n: Stations (Max. stations) Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C 8-7-Main Office: () 88--Outside Local rea: (8) 8--

16 pprox. X [.] 7 [.] ase Mounted Series VQZ// Dimensions: VQZ VVQZ- Grommet (G) Stations ort size.8 [7.8] pprox. (Lead wire length) L-type plug connector (L) C ().7 (.8) (7.).7.7 [.] D side L R R 7 L (itch) = (itch) = /8 [(), () port] (itch) = pprox.. [.8] 7. [.8] x ø. L L () (Rail mounting hole pitch:.) L (Station ) /8 R R U side (8) (Station n) (DIN rail clamp thread) (.) 7. [7.] (DIN rail) () M-type plug connector (M) 7. One-touch fitting [(), () port] pplicable tubing O.D.: ø, ø/" ø, ø/" ø8, ø/". [.]. [.8] 7. [.8] pplicable cable O.D. ø. to ø7 Max. 8. [.] DIN terminal (Y) R R External pilot E port / [(), (R), (R) port]..8 (7.8) g7 (.). M x.8 (External pilot port) 7.. The dashed lines indicate the DIN rail mounting [-D]... SJ SY SV SYJ SZ V S7 VQ VQ VQ VQC VQZ SQ VFS VFR VQ7 The dashed lines indicate the DIN rail mounting [-D]. Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Dimensions L n L L L L L The dashed lines indicate the DIN rail mounting [-D]. Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C The dashed lines indicate the DIN rail mounting [-D]. Unless otherwise indicated, dimensions are the same as Grommet (G). Formula: L = n + L = n + n: Stations (Max. stations) Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C 8-7-Main Office: () 88--Outside Local rea: (8)

17 pprox. (Lead wire length) L L (Rail mounting hole pitch:.) L (8) L L (itch) = R (.) () () R Series VQZ// Dimensions: VQZ VVQZ- Grommet (G) Stations ort size C D side R R U side (DIN rail clamp thread) (DIN rail) 7. x ø E port M x.8 (X: External pilot port) (For external pilot) /8 [() port] () 7 (.). / [(R), (R) port] 8.. (Station ) (Station n) One-touch fitting [(), () port] pplicable tubing O.D.: ø, ø/" ø8, ø/" ø, ø/8" (.8) (7.). (itch) = / [(), () port] (itch) = / The dashed lines indicate the DIN rail mounting [-D]. L-type plug connector (L). [.7] pprox..8 [.] 7. [78.] 7. [7.] M-type plug connector (M) pprox..7 [.] 7. [.] 8.8 [8.8] 8. [.] DIN terminal (Y) pplicable cable O.D. ø. to ø7 Max g Dimensions L n L L L L L The dashed lines indicate the DIN rail mounting [-D]. Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C The dashed lines indicate the DIN rail mounting [-D]. Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C The dashed lines indicate the DIN rail mounting [-D]. Unless otherwise indicated, dimensions are the same as Grommet (G). Formula: L = n + L = n + n: Stations (Max. stations) Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C 8-7-Main Office: () 88--Outside Local rea: (8) 8--

18 ase Mounted Series VQZ// Manifold Options lanking plate assembly VVQZ-- (for VQZ) VVQZ-- (for VQZ) VVQZ-- (for VQZ) It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. SJ SY Restrictor spacer (pplicable to VQZ) VVQZ-- Mount a restrictor spacer between manifold base and valve, and thus making it possible to control cylinder speed by meter-out. 7 SV SYJ SZ V. S7 VQ Individual SU spacer VVQZ---M (-Q) (for VQZ) VVQZ--- (-Q) (for VQZ) VVQZ--- (-Q) (for VQZ) Supply port can be installed individually by mounting an individual supply spacer onto the manifold block. It s used for such cases that the different pressure should be supplied into each valve, etc. Individual EXH spacer VVQZ-R--M (-Q) (for VQZ) VVQZ-R-- (-Q) (for VQZ) VVQZ-R-- (-Q) (for VQZ) D C M:VQZ Rc/8:VQZ Rc/:VQZ Dimensions Model VQZ VQZ VQZ Note) Grommet M:VQZ Rc/8:VQZ Rc/:VQZ C D Note) 7 8 VQ VQ VQC VQZ SQ VFS VFR VQ7 Exhaust port can be installed individually by mounting an individual exhaust spacer on to the manifold block. It s used for such cases that the valve exhaust is likely to affect other stations due to circuit, etc. D C Dimensions Model VQZ VQZ VQZ Note) Grommet C D Note) 7 8 ort plug VVQZ-C (for VQZ) VVQZ-C (for VQZ) VVQZ-C (for VQZ) Used to block a cylinder port when changing port valves into port valves, etc. Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C 8-7-Main Office: () 88--Outside Local rea: (8) 8--

19 Series VQZ// Manifold Options Name plate [-N] (pplicable to VQZ/) VVQZ-N- Stations (for VQZ) VVQZ-N- Stations (for VQZ) It is a transparent resin plate for placing a label that indicates solenoid valve function, etc. Insert it into the groove on the side of the end plate and bend it as shown in the figure. To order a manifold with nameplate already attached, insert N at the end of the manifold number clips are attached for name plate mounting. DIN rail XT-DR- s for, enter the number from the DIN rail dimensions table. For L dimension, refer to the dimensions of each kit. Each manifold can be mounted on a DIN rail. Order it by indicating an option symbol for DIN rail mounting, -D. The DIN rail is approximately mm longer than the length of manifold. L Dimension No. L dimension No. L dimension L () () L =.n lanking plug KQ- KQ- KQ- KQ-8 KQ- L ød Dimensions pplicable fitting size ød. 8 Model KQ- KQ- KQ- KQ-8 KQ- L D 8.. (mm). 8 Silencer (for manifold EXH port) Silencer is installed in the manifold EXH port. 8 ø ø N- N- Model Silencer part no. VQZ N- VQZ N- VQZ N- Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C 8-7-Main Office: () 88--Outside Local rea: (8) 8--

20 ase Mounted Series VQZ// Manifold Options erfect block (Separated): For VQZ VQ-FG- It is used on the outlet side piping to keep the cylinder in the intermediate position for a long time. Combining the perfect block with a built-in pilot type perfect valve and a position exhaust center solenoid valve will enable the cylinder to stop in the middle or maintain its position for a long time. The combination of a position single or double solenoid with a perfect block will prevent the cylinder from dropping at stroke end when residual supply pressure is released. Specifications Maximum operating pressure Minimum operating pressure mbient and fluid temperature Flow characteristics: C Max. operating frequency Dimensions Single unit M mounting hole. (). M. mounting hole (). How to Order erfect block 8 () (.) ().. () Residual pressure release (7.) (.). VQ-FG- C M - F.8 Ma. Ma to C. dm /(s bar) 8 c.p.m n x one-touch fitting assembly (, port) pplicable tubing O.D.: ø, ø. 7.7 n x M x.8 n x one-touch fitting assembly (, port) pplicable tubing O.D.: ø., ø, ø Dimensions L n L L L n L L L L IN side port size OUT side port size C C ø one-touch fitting ø one-touch fitting M C M thread ø. one-touch fitting C ø one-touch fitting C ø one-touch fitting Manifold (DIN rail mounting style) VVQ-FG- Order DIN rail Stations mounting style [-D] station for perfect block. stations <Ordering Example> VVQ-FG- stations of manifold VQ-FG-CM-D, sets erfect block VQ-FG-CM-D, sets Note) ased on JIS 87-8 (Supply pressure:. Ma) Manifold SMC SMC Formula L = n + n: Station (Maximum stations) Option Nil None DIN rail mounting D (For manifold) F With bracket N Name plate NI NI Residual pressure release OUT OUT. <Check valve operating principle> L L L To CYL port = D side Stations n n x M x.8 n x one-touch fitting assembly (, port) pplicable tubing O.D.: ø., ø, ø (R) () (R) Note) When two or more symbols are specified, indicate them alphabetically. Example) -DN Caution Since air leakage from the pipe between the valve and cylinder or the fittings will prevent the cylinder from stopping for a long time. Check for air leakage using neutral household detergent, such as dish washing soap. lso check the cylinder s tube gasket, piston packing and rod packing for air leakage. Since one-touch fittings allow slight air leakage, screw piping (with M thread) is recommended when stopping the cylinder in the middle for a long time. Combining perfect block with position closed center or pressure center solenoid valve will not work. M fitting assembly is attached, without being incorporated in the perfect block. fter screwing in the fittings, mount the assembly on the perfect block. (Tightening torque:.8 to. N m) If exhaust side of perfect block is narrowed down too much, intermediate stopping accuracy will be decreased. Cylinder side pressure () DIN rail clamp thread U side SU side pressure () n x one-touch fitting assembly (, port) pplicable tubing O.D.: ø, ø <Example> position position/exhaust center Drop prevention () () (R) (R) () () (R) (R) Intermediate stop (R) () (R) () () <racket assembly> art no. Tightening torque Note) VQ-. to. N m FG-F Note) It is the tightening torque for mounting a bracket for the perfect block. Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C 8-7-Main Office: () 88--Outside Local rea: (8) 8-- SJ SY SV SYJ SZ V S7 VQ VQ VQ VQC VQZ SQ VFS VFR VQ7

21 + + IN IN Series VQZ// Manifold Options erfect block (Separated): For VQZ/ VQ-FG- - It is used on the outlet side piping to keep the cylinder in the intermediate position for a long time. Combining the perfect block with a built-in pilot type perfect valve and a position exhaust center solenoid valve will enable the cylinder to stop in the middle or maintain its position for a long time. The combination of a position single or double solenoid with a perfect block will prevent the cylinder from dropping at stroke end when residual supply pressure is released. Specifications Maximum operating pressure Minimum operating pressure mbient and fluid temperature Flow characteristics: C Max. operating frequency Dimensions 7 VQ-FG- - F Manifold (DIN rail mounting style) VVQ-FG- Order DIN rail mounting style [-D] for perfect block. Single unit. 8 (.) 8. How to Order erfect block 7. (.) 7. x M mounting hole. x M mounting hole. (). () Residual pressure release (.) IN side port size Rc /8 Rc / C ø one-touch fitting C8 ø8 one-touch fitting IN () (.) Stations station.8 Ma. Ma to C. dm /(s bar) 8 c.p.m x Rc /8, / x one-touch fitting assembly (, port) pplicable tubing O.D.: ø, ø8.. 8 (.) (For C, C8) (.) (For C, C8) x Rc /8, / x one-touch fitting assembly (, port) pplicable tubing O.D.: ø, ø8 Dimensions L L L L OUT side port size Rc /8 Rc / C ø one-touch fitting C8 ø8 one-touch fitting stations <Ordering Example> VVQ-FG- stations of manifold VQ-FG-CC-D, sets VQ-FG-C8C8-D, sets erfect block Manifold n Caution SMC SMC Note) ased on JIS 87-8 (Supply pressure:. Ma) Option Nil None F With bracket DIN rail mounting D (For manifold) N Name plate DIN rail clamp thread <Check valve operating principle> L L L = To CYL port Residual pressure release D side Stations n x Rc /8, / x one-touch fitting assembly (, port) pplicable tubing O.D.: ø, ø8 Note) When two or more symbols are specified, indicate them alphabetically. Example) -DN Formula L = n + n: Station Since air leakage from the pipe between the valve and cylinder or the fittings will prevent the cylinder from stopping for a long time. Check for air leakage using neutral household detergent, such as dish washing soap. lso check the cylinder s tube gasket, piston packing and rod packing for air leakage. Since one-touch fittings allow slight air leakage, screw piping is recommended when stopping the cylinder in the middle for a long time. Combining perfect block with position closed center or pressure center solenoid valve will not work. When screwing the fittings in the perfect block, proper tightening torque for screws is as shown at the right. Set the cylinder load so that the cylinder Connection thread Rc /8 Rc / (R) () (R) IN IN roper tightening torque (N m) 7 to to pressure will be within two times that of the supply pressure. If exhaust side of perfect block is narrowed down too much, intermediate stopping accuracy will be decreased. 7. IN Cylinder side pressure () (.) 8 (For C, C8). SU side pressure () x Rc /8, / x one-touch fitting assembly (, port) pplicable tubing O.D.: ø, ø8 U side (.) (For C, C8) <Example> position position/exhaust center Drop prevention (R) (R) () () (R) (R) Intermediate stop (R) () (R) () () () () <racket assembly> art no. Tightening torque Note) VQ-.8 to. N m FG-F Note) It is the tightening torque for mounting a bracket for the perfect block. Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C 8-7-Main Office: () 88--Outside Local rea: (8) 8--

22 ase Mounted Series VQZ// Compact ody Type with Restrictor: For VQZ Restrictors are built into the valve body, making it easier to adjust cylinder speed. Needle valve is equipped with a retainer to prevent accidental needle loss. Symbol (Single) Manifold art No. VVQZC Valve art No. Flow Characteristics Flow rate (l/min (NR)) 7 8 Fully open Number of needle rotations (turns).7ma.ma.ma.ma Note ) Valve with restrictors is available on rubber seal models only. Note ) Since the body (of this type) is made compact, there is no interchangeability with the standard VQZ. Note ) Tightening torque of needle valve lock nut should not exceed. N m. Series VQZ Compact body Stations Manifold type stations ase mounted stations C C Specifications Single Double Closed center Exhaust center Metal (Without restrictor) (Without restrictor) (With restrictor) Metal (Without restrictor) (Without restrictor) (With restrictor) Metal (Without restrictor) (Without restrictor) (With restrictor) Metal (Without restrictor) (Without restrictor) (With restrictor) D VQZ M Symbol position single position double position closed center position exhaust center ody type ase mounted Seal type Restrictor Nil None With S Note) Note) vailable with rubber seal valve only. Function Symbol Specifications DC C Nil Standard (. W) Note ) K Note ) High pressure type ( type only) (. W) Note ) Option Note ) For C specification power consumption, refer to page. position position C [Option] Configuration Note ) Flow characteristics Response time (ms) Note ) Model / ( /) / / (/ E/E) Standard: pressure: C (g) High Mass C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv. W. W VQZ- -C or less or less or less VQZ- -C or less or less or less VQZS- -C or less or less or less VQZ- -C or less or less or less VQZ- -C or less or less or less VQZS- -C or less or less or less 8 VQZ- -C or less or less or less VQZ- -C or less or less 7 or less VQZS- -C or less or less 7 or less 8 VQZ- -C or less or less or less VQZ- -C or less or less 7 or less VQZS- -C or less or less 7 or less 8 Note ) ased on JIS 87-8 (Value for supply pressure of. Ma, with light/surge voltage suppressor, when using clean air). Response time values will change depending on pressure and air quality. The values at the time of ON are given for double styles. Note ) Weight without sub-plate ort size [(), () port] C ø. one-touch fitting C ø one-touch fitting C ø one-touch fitting Rc /8 Note ) The one-touch fittings on the compact manifold are pressed in and therefore cannot be changed out. Note ) For inch size one-touch fittings, refer to page. Coil voltage VC (/ Hz) VC (/ Hz) VC [ VC] (/ Hz) VC [ VC] (/ Hz) VDC VDC Option Nil None DIN rail mounting D (With standard DIN rail length) DIN rail mounting D Note) (Without DIN rail) Note) Order DIN rail separately. For DIN rail part no., refer to page. Compact body ort size Symbol ort size Nil Without sub-plate Rc /8 Note) For inch size one-touch fittings, refer to page. Nil Non-locking push type (Tool required) Locking type (Tool required) CE compliant Nil Q CE marked CE compliant Nil Q CE marked Electrical entry G Grommet (DC specification) L Note) L-type plug connector with lead wire LO Note) L-type plug connector without connector M Note) M-type plug connector with lead wire MO Note) M-type plug connector without connector Note) With light/surge voltage suppressor for L, LO, M, MO Sub-plate art No. VQZC-S- (-Q) Thread type lanking late ssembly VVQZC-- Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C 8-7-Main Office: () 88--Outside Local rea: (8) 8-- SJ SY SV SYJ SZ V S7 VQ VQ VQ VQC VQZ SQ VFS VFR VQ7

23 Series VQZ// Dimensions: VQZ (Compact ody Type: Single Unit) VQZ - G --C- Grommet (G).8 /8 [(), () port]. x ø... pprox Restrictor 8. E E... MX. X. /8 [(), (E), (E) port] M x.8 (External pilot port) (External pilot only) L-type plug connector (L) M-type plug connector (M) pprox. 8. [.]. 8. [8.] E E 8. [.] pprox. E E [ ]: C [ ]: C Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C 8-7-Main Office: () 88--Outside Local rea: (8) 8--

24 ase Mounted Series VQZ// Dimensions: VQZ (Compact ody Type: Manifold) VVQZC- Stations ort size D side Grommet (G) L (.8).. () (7.) L-type plug connector (L) C 8 R.7.7 pprox. L (itch) = L L (Rail mounting hole pitch:.) L (Station ) /8 (itch) = /8 [(), () port] (itch) =. [7.] R (Station n) U side (DIN rail clamp thread) (8) (.) () (DIN rail) () 7. x ø One-touch fitting [(), () port] pplicable tubing O.D.: ø., ø/8" ø, ø/" ø, ø/" pprox. Max..7 M-type plug connector (M).7. pprox. (Lead wire length) 8. /8 [(), (R) port].. (.). The dashed lines indicate the DIN rail mounting [-D].. [8.]. SJ SY SV SYJ SZ V S7 VQ VQ VQ VQC VQZ SQ VFS VFR VQ7 The dashed lines indicate the DIN rail mounting [-D]. Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C 7.8 [.] 8. [.8] 7. [7.] The dashed lines indicate the DIN rail mounting [-D]. Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C. [.8] [.] 8. [8.] Dimensions L n L L L L L Formula: L = n + L = n + n: Stations (Max. stations) Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C 8-7-Main Office: () 88--Outside Local rea: (8) 8--

25 Series VQZ Options ase Mounted External ilot Specification The external pilot specification is used when the operating pressure is below the minimum operating pressure. to. Ma or when valve is used for a vacuum application. Order a valve by adding the external pilot specification [R] to the part number. Valve art No. VQZ R Manifold art No. Entry is the same as standard products. VVQZ C R Entry is the same as standard products. Metal seal Rubber seal Operating pressure range Note) External pilot port ressure Specifications VQZ// Series position single position double position Note) External pilot pressure range. to.7 Ma VQZ, position only. to.7 Ma. to.7 Ma. to.7 Ma. to.7 Ma ka to.7 Ma Note) In case of the high pressure type, upper limit of max. operating pressure and external pilot pressure range is Ma. Inch Size One-touch Fittings and Optional Threads Inch size one-touch fittings and NT, NTF and G thread are available. Manifold art No. VVQZ N7 TC Valve art No. Entry is the same as standard products. Cylinder port Symbol N N N7 N N NM Note ) M pplicable tubing ø/8" ø/" ø/" ø/" ø/8" Mixed M /8 / O.D. thread thread thread VQZ Cylinder port VQZ VQZ (Compact) VQZ Note ) Mixing one-touch fittings and thread types is impossible. Note ) Metric size one-touch fittings (C ) are also available. VQZ T Thread type (Cylinder port and (), (R), (R) ports) Nil N T F Rc NT NTF G Entry is the same as standard products. I Enclosure (ased on IEC) DIN terminal is available with I enclosure. How to Order Single Valve (pplicable to the VQZ/ rubber seal with the exception of the external pilot type) VQZ Y W Entry is the same as standard products. Thread type (Cylinder port and (), (R), (R) ports) Nil N T F Rc NT NTF G Note) The pilot exhaust I valves is common with main valve exhaust. (The standard valve has an individual exhaust for the pilot valve.) Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C 8-7-Main Office: () 88--Outside Local rea: (8) 8--

26 Series VQZ ase Mounted Replacement arts One-touch Fitting ssembly (for Cylinder port) Model Fitting size VQZ VVQ--C VQZ VQZ Note) urchasing order is available in units of pieces. Without lead wire: SY-- (with connector and sockets only) Lead wire length Nil mm mm mm mm mm mm mm mm How to Order Include the connector assembly part number together with the part number for the plug connector s solenoid valve without connector. Example) In case of mm of lead wire DC VQZ-LO-M SY--- C VQZ-LO-M SY--- <Gasket and screw assembly> art no. VQZ VQZ-GS- VQZ VQZ-GS- VQZ VQZ-GS- Note) bove part number consists of units. Each unit has one gasket and two screws. urchasing order is available in units of pieces. <Sub-plate> Model VQZ VQZ VQZ Thread type <lug connector assembly> DC: SY--- VC: SY--- VC: SY--- Other C voltages: SY--- Sub-plate part no. VQZ-S- (-Q) VQZ-S- (-Q) VQZ-S- (-Q) C C C C8 C VVQ--C VVQ--C <ilot valve assembly> V VVQ--C VVQ--C VVQ--C Function Symbol Specifications DC C Nil Note) Standard High speed response type (. W) (. W) K Note) High pressure type (. W) ( type only) Note) Option Coil voltage VC (/ Hz) VC (/ Hz) VC [ VC] (/ Hz) VC [ VC] (/ Hz) VDC VDC DC G LU LOU MU MOU <DIN terminal type (pplicable to the VQZ/)> V Symbol Function Symbol Specifications DC C Nil Note) Standard High speed response type (. W) (. W) K Note) High pressure type (. W) ( type only) Note) Option Coil voltage VC (/ Hz) VC (/ Hz) VC [ VC] (/ Hz) VC [ VC] (/ Hz) VDC VDC G C LZ LOZ MZ MOZ Symbol Y YO YZ YS YOS VVQ--C8 VVQ--C8 Y X VVQ--C pplicable model (Length of screws attached is different from each other.) Nil VQZ/ and side of VQZ single, double solenoid type side of VQZ position side of VQZ position Electrical entry Light/surge Electrical entry voltage suppressor Grommet (DC specification) None L-type plug connector with lead wire L-type plug connector without connector Yes M-type plug connector with lead wire M-type plug connector without connector Electrical entry Electrical entry DIN terminal DIN terminal without connector DIN terminal with light/surge voltage suppressor DIN terminal with surge voltage suppressor (DC specification) DIN terminal with surge voltage suppressor, without connector (DC specification) Note) For C voltage valves there is no S option. It is already built-in to the rectifier circuit. Light/surge voltage suppressor None Yes Yes (Without light) Caution When replacing only the pilot valve assembly, use caution because it is not possible to convert to a V (DIN terminal) from a V (Grommet, L-type, M-type), or vice versa. Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C 8-7-Main Office: () 88--Outside Local rea: (8) SJ SY SV SYJ SZ V S7 VQ VQ VQ VQC VQZ SQ VFS VFR VQ7

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series

More information

Example. U side. Stations SY5000

Example. U side. Stations SY5000 45 Type 5 ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN ail Mounted/Individual Wiring Series SY3000/5000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 3 45 05 U C6 Example

More information

Series SV1000/2000/3000/4000

Series SV1000/2000/3000/4000 Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve ubber Seal / ort Solenoid Valve Series 000 / 000 / 000 [Option] SJ SY SV SZ V S000 VQ VQ VQ VQC VQZ SQ VFS VF VQ Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type1P Type2P 5 Port Solenoid Valve ase Mounted Manifold ar Stock Type/Flat Ribbon Cable Series /5000/000 How to Order Manifold Type 1P/Compact style SS5Y 5 1P 05 C8 Manifold series 3 5, port size Thread

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high

More information

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating / ort Solenoid Valve ubber Seal Series SYJ000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Specifications JIS Symbol port port (manifold) position

More information

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot ubber seal ort ilot Solenoid Valve Series SYJ00 Specifications efer to www.smcworld.com for details of products compatible with overseas standards. Body ported Base mounted Fluid Operating pressure range

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type20P 5 Port Solenoid Valve ody Ported Manifold ar Stock Type/Flat Ribbon Cable Series SY3000/5000/7000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 5 20P 05 Manifold series 3 SY3000

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M. V3 Cover

More information

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve CT.ES8 / ort Solenoid Valve Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M.7 to M2. 앬 Flow Characteristics Series Cover (stainless

More information

Series SY3000/5000 How to Order Manifold

Series SY3000/5000 How to Order Manifold Type N ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN Rail Mounted/Connector ox SY/ How to Order Manifold SSY SY SY Specifications Symbol Specifications With connector box (COM spec.) N With

More information

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC Base Mounted Series VQZ00/00/00 VQZ00/00 / How to Order Valve Made to Order (For details, refer to page 9 and 4.) VQZ 5 5 M Series VQZ00 body width 5 mm VQZ00 body width 8 mm Type of actuation 4 N.C. N.O.

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308 Cable ppendix Cable ppendix Multi-way cables The multi-pole connector cables used on SMC valves are common across several ranges. Cables are available in accordance with the MIL standard C-08 and also

More information

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit CT.EUS8 UK ower Consumption / ort Solenoid Valve With ower Saving Circuit Series SYJ000/000/7000 Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Series VQ Rubber Seal Space-saving profile Clean space saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector

More information

0.35 W (Without light)

0.35 W (Without light) Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:

More information

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

More information

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to

More information

4/5 Port Air Operated Valve. SYJA3000 Series. How to Order. (Manifold use only) Type of actuation. 2 position single. 3 position closed center

4/5 Port Air Operated Valve. SYJA3000 Series. How to Order. (Manifold use only) Type of actuation. 2 position single. 3 position closed center 4/ ort ir Operated Valve SYJ000 Series How to Order ody ported SYJ M racket Nil Without bracket F With bracket *Refer to page 47 for the details of the brackets. ase mounted (4 port) SYJ 2 0 (Manifold

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 0 PW COM Rubber Seal Port Solenoid Valve Series SZ000 Cassette Type Manifold The plug-in cassette system makes valve replacement easy. plug-in manifold has been created with a height of. mm (including

More information

VQ1000. How to Order Manifold. Kit type

VQ1000. How to Order Manifold. Kit type - - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I ISO Standard Solenoid Valve Series VQ7-6/7-8 (Size ) (Size ) Conforms to ISO Standard /I.0- Ideal for driving cylinders up to Large flow capacity ø00 (VQ7-6, Size ) ø60 (VQ7-8, Size ) Nl/min VQ7-6: 668.

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3

More information

3 Port Air Operated Valve. SYJA300 Series. How to Order. Nil Without sub-plate. Type of actuation. Normally closed Normally open

3 Port Air Operated Valve. SYJA300 Series. How to Order. Nil Without sub-plate. Type of actuation. Normally closed Normally open 3 ort ir Operated Valve SYJ300 Series How to Order SYJ3 M3 Bracket Nil Without bracket F With bracket *The bracket is not mounted. *The bracket cannot be retrofitted later. SYJ3 Type of actuation Normally

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring Type4 SY000/000 ase Mounted Monifold Stacking Type/DIN ail Mounted Individual Wiring How to Order Manifold SSY 4 0 U C6 How to Order Valve Manifold ssembly Ordering example SY000 SY000 Valve stations 02

More information

3 Port Solenoid Valve

3 Port Solenoid Valve 3 ort Solenoid Valve Series VKF300 ubber Seal Direct Operated oppet Type Compact yet provides a large flow capacity Body width 8 mm vailable in vacuum applications ( 0. ka) Can be used in vacuum/release

More information

Series SYJ300/500/700

Series SYJ300/500/700 ort Solenoid Valve ubber Seal Series SYJ00/00/00 Low power consumption: 0.W (Without light) (Current draw: 1m at 4V DC) Completely interchangeable ilot exhaust with the previous series VJ00/00/00 and VZ00/00.

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR2 JIS Symbol type

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Rubber Seal Series VQ Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000) 5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model 2 position 3 position

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Port Solenoid Valve Metal Seal Rubber Seal Series Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

How to Order Manifold. Kit type L8 B4 B6 B8 LM

How to Order Manifold. Kit type L8 B4 B6 B8 LM 0 Stations station VVQ Series VQ000 The maximum and minimum number of are varied depending on. (Refer to the table below.) Series VQ000 ase Mounted Plug-in Unit Manifold Plug-in unit 08 C Cylinder port

More information

Base Mounted Plug-in/Plug Lead: Single Unit

Base Mounted Plug-in/Plug Lead: Single Unit ase mounted VQ ase Mounted lug-in/lug Lead: Single Unit Model Number of solenoids Model Single Metal seal VQ Rubber seal VQ ouble Metal seal VQ Rubber seal VQ Closed Metal seal VQ VQ center Rubber seal

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing

More information

Series SYJ3000/5000/7000

Series SYJ3000/5000/7000 , ort Solenoid Valve ubber Seal Series SYJ000/000/7000 Low power consumption: 0.W(Without light) (Current draw: 1m at V DC) right color tone and state of the art design SY SYJ SX VK VZ VF VF V7 V Completely

More information

5 Port Solenoid Valve Plug Lead Type

5 Port Solenoid Valve Plug Lead Type 5 Port Solenoid alve Plug Lead Type Series Body Ported Flow rate characteristics For single/double solenoid C [dm 3 /(s bar)]: 0.6 Single Unit alve width: 7.4 mm Possible to drive cylinders: Up to ø32

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000 D-sub Connector J Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000//000 Number of connectors: pins MIL-C-08 Conforming to JIS-X-0 --6 For details

More information

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection Rubber Seal Port Solenoid Valve Series SJ000/000 Cassette Type Manifold 0 mm 7. mm (SJ000) 0 mm (SJ000) Non plug-in type Individual wiring manifold SJ000 SJ000 Can be mounted together. Connecter connection

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

Gateway System Serial Transmission System

Gateway System Serial Transmission System Gateway System Series 00 I compliant V S000 C Tie-rod base Z pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000/000/000 Number of output points: points Connected to the 00GW

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A Type N SY/ ase ounted anifold Stacking Type/DIN Rail ounted Connector ox How to Order anifold SSY SY SY Specifications Symbol Specifications With connector box (CO spec.) N With connector box ( CO spec.)

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Series 000 Compact and lightweight: 3 mm width Compact yet provides

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle. Multistage Ejector 112/212 Series Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series

More information

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A) ort Solenoid Valve ubber Seal Series SY00 Low power consumption: 0.W (Standard, Without light) (Current draw: m at V DC) Large flow capacity style:0.7w (Current draw: m at V DC) Body width: 0mm 7.8 Nl/min

More information

3 Port Air Operated Valve

3 Port Air Operated Valve Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

Flow characteristics Max. (1) b Standard Specifications. P Manual override.

Flow characteristics Max. (1) b Standard Specifications. P Manual override. Port Direct Operated Solenoid Valve Series 0 Metal Seal Model Number of positions (Single) (Double) ( position) JIS Symbol Model Port size Rc (Nominal size) 0-0 8 ( A) 0- ( 8A) 0-0 8 (0A) 0-0 8 ( A) 0-

More information

5 Port Air Operated Valve

5 Port Air Operated Valve Port ir Operated Valve Series VF000/000/000 RoHS 22- Series VF000/000/000 Model Selection by Operating Conditions q ir Operated Valve: Single Unit Series Sonic conductance C[dm /(s bar)] Type of actuation

More information

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications Series -SQ00 Port Solenoid Valve Plug-in Unit [Option] How to Order Manifold Electrical entry F kit D-sub connector kit P kit SSQ 08 FD Kit type Flat ribbon cable connector kit J kit Flat ribbon cable

More information

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes

More information

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Soft Start-up Valve. AV2000/3000/4000/5000 Series Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot 3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in

More information

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles ort Solenoid Valve: ase Mounted Metal Seal/Rubber Seal Series Space and capacity saving ilot valve is gathered at one side. Space saving design which does not have any protrusions. Space saving Capacity

More information

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type. Series -S00 ompact Direct Operated Port Solenoid Valve ontrol Valves ase mounted ody ported lean Series lean Series V S R oil voltage 24 VD VD VD VD VD Power consumption Pressure specification Flow rate

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Vacuum Release Valve with Restrictor Series SJ3A6 SJ Plug-in Type Connector Connection P.86 D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Non Plug-in Type Individual

More information

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

Manifold Specifications Stacking Type

Manifold Specifications Stacking Type Specifications Stacking Type Keeps environmental air clean from pilot exhaust Use of the VV5FS- manifold can exhaust intensively the pilot exhaust gas to the base side, and can prevent environmental aggravation

More information

Manifold Specifications

Manifold Specifications Series 00 Manifold Specifications Manifold Specifications Model Manifold type P(SUP)/R(EXH) Valve stations A port porting specifications Port size For internal pilot For external pilot Location Direction

More information

Coolant Valve. Air Operated/External Pilot Solenoid

Coolant Valve. Air Operated/External Pilot Solenoid Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) lange type (3 to ) Low water hammer or details, refer to page

More information

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve CT.E- ase Mounted Type Series VQ Port Metal Seal/Rubber Seal Solenoid Valve dvanced manifold va the new age of factory au ase Mounted Type Space saving profile Clean space saving design with all pilot

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 044 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000 racket

More information

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC)

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC) Port Solenoid Valve/Direct Poppet Rubber seal Series VK3000 Nl/min 147 Compact/Width 18 X Length 8 (mm) Low power consumption 4W DC (Standard) 2W DC (Energy saver) Standard copper free specification All

More information

Fieldbus System (Output device for driving 5 port solenoid valves)

Fieldbus System (Output device for driving 5 port solenoid valves) Fieldbus System (Output device for driving port solenoid valves) New Compact 8mm (ctual size) Space-saving Installation IP67 RoHS EtherNet/IP added! For units with D-sub connector, and when connected to

More information

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series VZS Series Variations Plug-in Type Base Mounted Type (With sub-plate) Non Plug-in Type Base Mounted Type (With sub-plate) Series Sonic conductance

More information

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S. High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure of 0.5MPa, subject to clean, dry air) 4 Port Direct

More information

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) type (3 to ) Low water hammer or details, refer to page 07. Large

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry TEX Compliant Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 44 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000

More information

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types Speed 2 Port Valve Series RoHS speed speed speed response response response 5 ms 9mm Width ±0.05 ms ±0.05 ms type VCH : : 5 ms * The response time is measured based on SMC test conditions. (Not guaranteed

More information

3 Port 3 Position Valve

3 Port 3 Position Valve Port Position Valve Pilot Solenoid ir Operated ohs Intermediate stopping of cylinders * up to ø15 is possible. Pilot solenoid Manifold ir operated * For VEX 4, 00 mm/s, horizontal movement Power consumption:

More information