Manifold Specifications Stacking Type

Size: px
Start display at page:

Download "Manifold Specifications Stacking Type"

Transcription

1 Specifications Stacking Type Keeps environmental air clean from pilot exhaust Use of the VV5FS- manifold can exhaust intensively the pilot exhaust gas to the base side, and can prevent environmental aggravation due to noise and oil mist. VV5FS- for mounting bolt and gasket BG-VFS00 Exploded View of block assembly VVFS000-A-0 Hexagon socket head cap screw: M4 x 5 (AXT5-7-) Specifications Port Specifications Option base type (P) Common Passage (R), 5(R) Common How to Order Base Stacking type Max. 5 stations Porting specifications: Rc Base Valve Base (P) Side: 8 (B), 4(A) Top:, 4 8 (R), 5(R) Side: 8 Blanking plate VVFS000-0A- With gasket, screw SUP block disk AXT66-0A EXH block disk AXT66-A Note) Individual SUP or EXH is possible with bottom porting of SUP or EXH. For your order, please indicate it in the manifold specification sheet. VV5FS 05 0 stations 5 5 stations Thread type Nil Rc N NPT T NPTF F G Option P, EA, EB port size 0-Rc 8 Passage Porting specifications (P) (R), 5(R) (B), 4(A) Common Common Top Rc 8 Rc 8 Rc, Rc 4 8 VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Gasket Base model Model Pilot exhaust Pilot common EXH Applicable valve model Type 0 Type 0 VFS VFS Note) Also VFS 0 is possible to manifold. In this case, it uses an individual pilot exhaust. For increasing the manifold bases, please prepare the manifold block assembly no. How to Order Assembly Instruct by specifying the valves and blanking plate to be mounted on the manifold along with the manifold base model no. <Example> ( base) ( position single) ( position double) (Blanking plate) VV5FS VFS0-D- VFS0-D- VVFS000-0A- -8-

2 Type Grommet: G Pilot common exhaust: VV5FS-- Station -0 n-rc /4, /8 M4 x 5 Rc /8 External pilot port 6-Rc /8 4-ø7 mounting hole P = Blanking plate 4-Rc /8 Pilot EXH port: PE 00 (Lead wire length) Gasket Formula for manifold weight M = 0.84n (kg) n: Station Grommet terminal: E/EZ Conduit terminal: T/TZ DIN terminal: D/DZ/Y/YZ Lead wire O.D. Max. ø.5 Applicable heavy-duty cord O.D. ø6 to ø8 Applicable heavy-duty cord O.D. ø6 to ø8 (Y: ø4.7 to ø7) position (04) Double (94) Single (5) position (4) Double () Single (5) position (40) Double (0) Single (5) 4-Rc /8 Pilot EXH port: PE (With light/surge voltage suppressor: 04.5) 6-Rc /8 6-Rc /8 4-Rc /8 Pilot EXH port: PE (With light/surge voltage suppressor: 09) 6-Rc /8 4-Rc /8 Pilot EXH port: PE (With light/surge voltage suppressor: 9.5 (.5)) L (With light/surge voltage suppressor: 4) L L (With light/surge voltage suppressor: 9) (With light/surge voltage suppressor: 8.5 (0.5)) ( ): Y, YZ n: Station Formula L = x n + 5 L = x n

3 Specifications Plug-in Type: With Terminal Block Since lead wires of solenoid valve are connected with the terminals on upper surface of terminal block, corresponding lead wires from power source can be wired at the bottom of terminal block. Master connection of power and solenoid valves. Quick wiring permits easier installation. Wide range of interchangeability (MIL Spec DIN connector terminal 5 pcs attached.) Quick wiring permits easier installation. VV5FS 0T with terminal block stations VV5FS D U D U 0 0C 0 stations Plug-in Type: With Multi-connector (Wiring specifications: Refer to page -8-8.) D Connector mounting with multi-connector Plug-in Type: With D-sub Connector Terminal block Multi-connector D-sub connector Plug assembly (Option) Refer to page VV5FS with D-sub connector Plug assembly (Option) Refer to page direction mounting mounting stations 0F mounting mounting Thread type Port size P, EA, EB A, B Nil N Rc NPT Rc 4 T Rc NPTF 0 Rc 8 F G M Mixed Option Passage Porting specifications P EA, EB (A, B) Side Common Common Bottom Option stations Max. 8 stations (Wiring specifications: Refer to page -8-8.) D Connector mounting direction stations 08 8 stations Max. 8 stations Thread type Port size Nil Rc P, EA, EB A, B N NPT Rc T NPTF 0 Rc Rc 8 F G M Mixed Option Passage Porting specifications P EA, EB (A, B) Side Common Common Bottom Option 06 4 Thread type Port size Nil Rc P, EA, EB A, B N NPT Rc T NPTF 0 Rc Rc 8 F G M Mixed Option Passage Porting specifications P EA, EB (A, B) Side Common Common Bottom Option VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Non Plug-in Type: Grommet Terminal, DIN Terminal Wiring for every valve. Grommet terminal DIN terminal VV5FS 0 0 stations 0 stations 05 Thread type Port size Nil Rc P, EA, EB A, B N NPT Rc T NPTF 0 Rc Rc 8 F G M Mixed Option Passage Porting specifications P EA, EB (A, B) Side Common Common Bottom Option -8-59

4 How to Order Assembly Please indicate manifold base type, corresponding valve, and option parts. <Example> with terminal block: 6 stations ( base) VV5FS-0T-06- ( position single) VFS00-5FZ ( position double) VFS00-5FZ (Blanking plate) VVFS000-0A <Example> : 6 stations ( base) VV5FS ( position single) VFS0-5D 5 ( position exhaust center) VFS40-5D (Individual EXH spacer) VVFS000-R-0- Option Parts Assembly Individual SUP spacer An individual SUP spacer set on manifold block can form SUP port for every valve. VVFS000-P-0- VVFS000-P-0- Specifications Base model VV5FS-0 VV5FS-0 Wiring With terminal block With multi-connector With D-sub connector DIN terminal Grommet terminal Flow Characteristics at the Number of (Operated individually) Model VV5FS Throttle valve spacer Needle valve set on the manifold block can control cylinder speed by throttling exhaust. Porting specifications A, B port Side/ Bottom Port size Rc P, EA, EB A, B () () 4, 8 to 0 Note ) Appropriate silencer for EA, EB port: AN40-04 (O.D. ø7). Note ) With multi-connector, or with D-sub connector: 8 stations max. Port size: Rc /8 Passage/ 4/ (P A/B) 4/ 5/ (A/B R/R) VVFS000-0A- C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv VVFS000-0A- Applicable valve model VFS 00- F VFS 0- D VFS 0- E Station Station 5 Station Option With exhaust cleaner /Non Valve exhaust noise dampening: 5 db or more. Oil mist collection: Rate of collection 99.9% or more. Piping process reduced. Individual EXH spacer An individual EXH spacer set on manifold block can form EXH port for every valve. (common EXH type) VVFS000-R-0- SUP block disk EXH block disk VVFS000-R-0- When supplying manifold with more than two different pressures, high and low, insert a block disk in between stations subjected to different pressures. AXT66-A When valve exhaust affects the other stations on the circuit or when the reverse pressure valve is used to standard manifold valve, insert EXH block disk between stations to separate valve exhaust. AXT66-A Double check spacer If the double check spacer with a built-in double check valve is combined, it will enable the cylinder to stop in the intermediate stroke and maintain its position for a long time without being affected by the leakage between the spools. VVFS000-A- VVFS000-A- Interface regulator Interface regulator set on manifold block can regulate the pressure to each valve. (Refer to page -8-6 for Flow Characteristics.) P port regulation A port regulation B port regulation ARBF P- ARBF A- ARBF B- ARBF P- ARBF A- ARBF B- For details, refer to page With control unit /Non Filter, regulation valve, pressure switch and air release valve are all combined to form one unit. Piping processes are eliminated. For details, refer to page With serial interface unit for serial transmission Solenoid valve wiring process reduced considerably. Disperse installation possible. solenoid valve: 8 stations max. positions (5 solenoids). Maintenance and inspection are easy Blanking plate It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. VVFS000-0A For details, refer to Serial Transmission catalog separately.

5 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in, (With terminal block): VV5FS-0T- Station - Port size n-rc 4, 8 Bottom ported: VV5FS-0T- Station - Port size Formula for manifold weight M = 0.405n (kg) n: Station -Rc 8 (Pilot EXH port: PE) : VV5FS-0- Station - Port size -G /4 Electrical entry n-rc 4, 8 Light window -Rc 8 (External pilot port) VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN n-rc 4, 8 n-rc 4, 8 Light window Bottom ported: VV5FS-0- Station - Port size Applicable cabtire cable O.D. ø8 to ø0 -Rc 8 (Pilot EXH port: PE) -Rc 8 (External pilot port) 6-Rc L Formula for manifold weight M = 0.09n (kg) L L n: Formula L = x n + 6 L = x n

6 with multi-connector/d-sub connector with multi-connector: VV5FS-0CD- Station - Port size, VV5FS-0CU- Station - Port size n-rc 4, 8 Bottom ported: VV5FS-0 - Station - Port size CD CU Plug assembly VVFS000-0A- (Option: Refer to page -8-8.) Light window n-rc 4, 8 -Rc /8 (Pilot EXH port: PE) -Rc /8 (External pilot port) 6-Rc / Formula for manifold weight M = 0.4n (kg) n: Station Wiring specifications: Refer to page with D-sub connector: VV5FS-0FD- Station - Port size, VV5FS-0FU- Station - Port size n-rc 4, 8 n-rc 4, 8 Light window Bottom ported: FD VV5FS-0 - Station - Port size FU Formula for manifold weight M = 0.4n (kg) n: Station Wiring specifications: Refer to page Plug assembly VVZS000-A- (Option: Refer to page -8-8.) -Rc /8 (Pilot EXH port: PE) -Rc /8 (External pilot port) L L L n: Formula L = x n + 6 L = x n Rc / -8-6

7 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in with Exhaust Cleaner Serves to protect working environment. Valve exhaust noise dampening: 5 db or more. Collection rate of drainage and oil mist: 99.9% or more. Piping work is reduced. Exhaust cleaner AMC60-0 (Option) Exhaust cleaner AMC60-0 (Option) Specifications Wiring : VV5FS-0 With terminal blocks With multi-connector With D-sub connector : VV5FS-0 DIN terminal Grommet terminal Applicable valve model VFS 00- F VFS 0- D, VFS 0- E Common SUP, Common EXH Porting specifications (B), 4(A) port Rc /4, /8 Rc (P), (R), 5(R) port P: Rc /, EXH: Rc to 0 () Applicable exhaust cleaners AMC60-0 (Connecting port size R ) () Note ) With multi-connector, or with D-sub connector: 8 stations max. Note ) Exhaust cleaner AMC60-0 is not attached. VV5FS Base type/electrical entry 0T 0C with terminal block with multi-connector 0F 0 with D-sub connector Connector mounting direction With connector Applicable base Nil D U None mounting mounting CD 0T, 0 0C, 0F stations 0 0 stations Base type 0T, 0: -0 stations Base type 0C, 0F: -8 stations How to Order Nil N T F Option Port size Exhaust cleaner mounting direction Exhaust cleaner mounting direction CD CU Thread type Rc NPT NPTF G P A, B Rc 4 Rc 0 Rc 8 M Mixed Passage Porting specifications P R, R (A, B) Side Common Common Bottom Option mounting mounting VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Caution When using an exhaust cleaner, mount it downwards. For details about exhaust cleaners, refer to Best Pneumatic Vol. 5. Please indicate manifold base type, corresponding valve, and option parts. <Example> with terminal block (6 stations) ( base) VV5FS-0T-06-0-CD ( position single) VFS00-5FZ ( position double) VFS00-5FZ (Blanking plate) VVFS000-0A (Exhaust cleaner) AMC60-0 (6 stations) ( base) VV5FS CU ( position single) VFS0-5E ( position double) VFS0-5E (Blanking plate) VVFS000-0A (Exhaust cleaner) AMC

8 with Exhaust Cleaner : VV5FS-0T- Station - Port size - CD CU, Pilot valve manual override Light n-rc 4, 8 Exhaust cleaner (Option) 5 -Rc /8 (Pilot EXH port: PE) -G /4 Electrical entry -Rc /8 (External pilot port: X) 6-Rc / mounting mounting : VV5FS-0- Station - Port size - CD CU n-rc 4, 8 Light 5 Exhaust cleaner (Option) -Rc /8 (Pilot EXH port: PE) -Rc /8 (External pilot port: X) 6-Rc / mounting mounting L L L n: Formula L = x n + 6 L = x n

9 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in with Control Unit Control unit (Filter, Regulator, Pressure switch, Air release valve) are all standardized to the one unit, and can be mounted on the manifold base without any attachments. Piping processes are eliminated. Specifications : VV5FS-0 : VV5FS-0 With terminal block DIN terminal Wiring With multi-connector Grommet terminal With D-sub connector Applicable valve model VFS 00- F VFS 0- D, VFS 0- E Common SUP, Common EXH Porting specifications (B), 4(A) port Rc /4, /8 Rc (P), (R), 5(R) port Rc / to 0 With multi-connector, or with D-sub connector: 8 stations max. Control Unit Specifications Air filter (With auto-drain/with manual drain) Filtration degree 5 µm Regulator Set pressure (Outlet pressure) 0.05 to 0.85 MPa Pressure switch () Set pressure range: OFF 0. to 0.6 MPa Differential 0.08 MPa or less Contact a Indicator light LED (RED) Max. switch capacity VA AC, W DC 4 VAC/DC or less: 50 ma Max. operating current 00 VAC/DC: 0 ma Air release valve (Single only) Operating pressure range 0. to.0 MPa VV5FS 0 08 AP Base type/electrical entry 0T with terminal block 0C with multi-connector 0F with D-sub connector 0 Connector mounting direction With connector Applicable base Nil None 0T, 0 D mounting 0C, 0F U mounting stations Passage 0 0 stations P EA, EB Base type 0T, 0: to 0 stations Common Common Base type 0C, 0F: to 8 stations Option Port size P, EA, EB Rc 0 M Caution When using an air filter with auto-drain or manual drain, mount the filter vertically. Porting specifications (A, B) Side Bottom How to Order A, B Thread type Rc 4 Rc Nil Rc 8 N Mixed NPT NPTF G T F Option Control Unit/Option Air release () valve spacer Pressure () switch Blanking plate <> VVFS000-4A-R ( mounting) <> VVFS000-4A-R ( mounting) Filter regulator Pressure switch Release valve IS000P-- MP- MP- VVFS000-4A-0 Filter element INA B Note ) Voltage: 4 VDC to 00 VAC Inner voltage drop: 4 V Note ) Combination of valve VFS (single) and a release valve spacer can be used an air release valve. Note ) The non plug-in type cannot be mounted afterwards. Air release valve coil rating Nil None (F, G type only) VAC, 50/60 Hz 4 VDC Other Control unit type Control equipment Nil A AP M MP F G C E Air filter with auto-drain Air filter with manual drain Regulator Air release valve Pressure switch Blanking plate (Air release valve) Blanking plate (Filter, Regulator) Blanking plate (Pressure switch) Number of manifold blocks required for mounting (stations) Please indicate manifold base type, corresponding valve, and option parts. <Example> with terminal block In order to mount control unit, it requires stations. ( base) ( position single) ( position double) <Example> VV5FS-0T-08-0-AP5 VFS00-5FZ VFS00-5FZ 4 In order to mount control unit, it requires stations. ( base) ( position single) VV5FS A VFS0-5D 4 VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN -8-65

10 with Control, : VV5FS-0T- Station - Port size -AP Voltage for release valve n-rc 4, 8 Example for manifold Individual EXH spacer (VVFS000-R-0-) Double check spacer (VVS000-A-) Individual SUP spacer (VVFS000-P-0-) 08 Light Pressure switch Air release valve (95: -MP) Rc / (Po port) -Rc /8 (External pilot port: X) Air release valve Air filter regulator Pressure switch Outlet for check Control unit -Rc 8 (Pilot EXH port: PE) 9 -G 4 Electrical entry : VV5FS-0- Station - Port size -AP Voltage for release valve n-rc 4, 8 Example for manifold (B) 4(A) (B) 4(A) (B) 4(A) Individual EXH spacer (VVFS000-R-0-) Double check spacer (VVFS000-A-) Individual SUP spacer (VVFS000-P-0-) Pressure switch Air release valve Light Air release valve Pressure switch Outlet for check (95: -MP) Air filter regulator Control unit 08 -Rc 8 (Pilot EXH port: PE) 9 Rc / (Po port) -Rc 8 (External pilot port: X) 6-RC / L L L L (MP) L (AP) Formula L = x n + 6 L = x n L = x n L = x n

11 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Option Parts Individual SUP spacer: VVFS000-P-0- () VVFS000-P-0- (), Double check spacer: VVFS000-A- () VVFS000-A- () (57: With direct manual override) Individual SUP spacer Individual EXH spacer: VVFS000-R-0- () VVFS000-R-0- () (57: With direct manual override) Individual EXH spacer SUP/EXH block disk: AXT66-A Interface regulator/p port regulation: ARBF P- () ARBF P- () (68: With direct manual override) Interface regulator Double check spacer Interface regulator/a port regulation: ARBF A- () ARBF A- () VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Block disk mounting position (68: With direct manual override) Interface regulator Throttle valve spacer: VVFS000-0A- () VVFS000-0A- () Interface regulator/b port regulation: ARBF B- () ARBF B- () (57: With direct manual override) Throttle valve spacer (68: With direct manual override) Interface regulator -8-67

12 Base Construction, End plate () End plate () Replacement Parts No. q w e r t y u i o! Description Connection fitting A Connection fitting B Gasket Gasket O-ring O-ring O-ring Terminal assembly Junction cover assembly Rubber plug Material Steel plate Steel plate NBR NBR NBR NBR NBR For 0T For 0SU NBR Replacement Parts: Sub Assembly VVFS000-5-A VVFS VVFS VVFS x 6.6 x.6 (End plate) 0 x 6 x ( block) 6. x x.6 VVFS000-6A VVFS000-4A- AZ78-A- AXT6-9 For increasing the manifold bases, please order the manifold block assembly number of the principal part assembly!0. For plug-in type: The manifold base with terminal stand (integrated with a junction cover) is required with the o junction cover assembly. Note) Base/Construction: Plug-in with terminal block. No. Description Assembly part no. Component parts Applicable manifold base!0!! block!0, Terminal i, Metal joint q, w, block VVFS000-A-- 0 Gasket e, r, O-ring y, u, Receptacle assembly assembly VVFS000-A-- block!0, Metal joint q, w, Gasket e, r, O-ring y, u 0 End plate () VVFS000-A- End plate (D)!, Metal joint q, w, Gasket e assembly VVFS000-A- End plate (D)!, Metal joint q, w, Gasket e End plate () assembly VVFS000-A- VVFS000-A- End plate (U)!, Metal joint q, w, O-ring t, y End plate (U)!, Metal joint q, w, O-ring t, y -8-68

13 .70 S OLENOID VALVES S ERIES NVFS H O W T O O R D E R NVFS000 NVFS 0 F P OSITION Position Single Position Double Position Closed Center 4 Position Exhaust Center 5 Position Pressure Center 6 Position Perfect B ODY T YPE 0 Plug-In Type P ORT S IZE - Without Subplate T /4 NPTF 0T /8 NPTF* * Not available for Bottom Ported P ORTING - Side *B Bottom Note) */8 NPTF Only M ANUAL O PTION 0 Standard Std & Direct Manual (Special Order) P ILOT O PERATOR - Internal R External (Special Order) V OLTAGE 00VAC (Special Order) 00VAC (Special Order) 0VAC 4 0VAc 5 4VDC 6 VDC 9 Others (Special Order) E LECTRICAL E NTRY F Through Base M ANUAL O VERRIDE - Non Locking Push Type (Flush) *A Non Locking Push Type (Extended) B Lock Type (Screw Type) *C Lock Type (Lever) Note) * Special Order O PTIONS - None Z With Indicator Light and Surge Voltage Suppressor H O W T O O R D E R M ANIFOLD FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT, REQUEST CATALOG REFERENCE N

14 S OLENOID VALVES S ERIES NVFS.7 H O W T O O R D E R M ANIFOLD / OPTION P ARTS ASSEMBLY S EE INSIDE FRONT COVER FOR DETAILS OF YOUR LOCAL SALES OFFICE FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT, REQUEST CATALOG REFERENCE N

Manifold Specifications

Manifold Specifications Specifications Plug-in Type: With Terminal Block Since lead wires of solenoid valve are connected with the terminals on upper surface of terminal block, corresponding lead wires from power source can be

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

Manifold Specifications

Manifold Specifications Specifications Specifications Base mounted VVFR-01 VVFR- VVFR-0 Wiring With terminal block With multi-connector With D-sub connector Grommet terminal DIN terminal Grommet Grommet terminal Conduit terminal

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model 2 position 3 position

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry

More information

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series VZS Series Variations Plug-in Type Base Mounted Type (With sub-plate) Non Plug-in Type Base Mounted Type (With sub-plate) Series Sonic conductance

More information

Manifold Specifications

Manifold Specifications Series 00 Manifold Specifications Manifold Specifications Model Manifold type P(SUP)/R(EXH) Valve stations A port porting specifications Port size For internal pilot For external pilot Location Direction

More information

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Body Ported Base Mounted Series S000 S000 S000 S000 S000 S4000 S5000 Sonic conductance C [dm /s bar)] 4/ 5/(A/B R/R) Single Double.8.4

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR2 JIS Symbol type

More information

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

5 Port Pilot Solenoid Valve Metal Seal. Configuration Voltage Electrical entry Option. Standard. 100V AC50/60Hz 200V AC50/60Hz 24V DC.

5 Port Pilot Solenoid Valve Metal Seal. Configuration Voltage Electrical entry Option. Standard. 100V AC50/60Hz 200V AC50/60Hz 24V DC. 5 Port Pilot Solenoid Valve Metal Seal SeriesVFS Models and Variations Body ported Base mounted Series VFS000 VFS2000 VFS3000 VFS2000 VFS3000 VFS4000 VFS5000 Port Size Effective area (mm 2 ) (Nl/min) 8:

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000) 5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

2.26 S OLENOID VALVES S ERIES VQ1000

2.26 S OLENOID VALVES S ERIES VQ1000 2.26 S OLENOID VALVES 5 PORT M ETAL S EAL/RUBBER S EAL U LTRA H IGH S PEED S OLENOID VALVE High Speed Response from new Solenoid Design. Long Life: Over 200 Million Cycles can be with Patent Pilot Valve

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high

More information

Flow characteristics Max. (1) b Standard Specifications. P Manual override.

Flow characteristics Max. (1) b Standard Specifications. P Manual override. Port Direct Operated Solenoid Valve Series 0 Metal Seal Model Number of positions (Single) (Double) ( position) JIS Symbol Model Port size Rc (Nominal size) 0-0 8 ( A) 0- ( 8A) 0-0 8 (0A) 0-0 8 ( A) 0-

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

ISO Standard Solenoid Valve/SIZEq Rubber Seal Series VP7 6

ISO Standard Solenoid Valve/SIZEq Rubber Seal Series VP7 6 ISO Standard Solenoid Valve/SIZq Rubber Seal Series VP7 6 VP7 6 FPG D VP7 6 FG D position position Single solenoid (FG-S) Double solenoids (FG-D) Reverse pressure (YZ-S) Reverse pressure (YZ-D) Closed

More information

5 Port Pilot Solenoid Valve Rubber Seal

5 Port Pilot Solenoid Valve Rubber Seal 5 Port Pilot Solenoid Valve Rubber Seal VF1000/3000/5000 Large flow capacity, Yet compact size. Low power consumption. 1.8WDC Exhausting equipment for pilot valve not required. Common exhaust for main

More information

NAMUR Interface 5 Port Solenoid Valve

NAMUR Interface 5 Port Solenoid Valve NAMUR Interface 5 Port Solenoid Valve Series VFN000N 5 5 Specifications Valve Electrical entry Fluid Max. operating pressure Min. operating pressure Ambient and fluid temperature Lubrication Pilot operator

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Series VQ Rubber Seal Space-saving profile Clean space saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I ISO Standard Solenoid Valve Series VQ7-6/7-8 (Size ) (Size ) Conforms to ISO Standard /I.0- Ideal for driving cylinders up to Large flow capacity ø00 (VQ7-6, Size ) ø60 (VQ7-8, Size ) Nl/min VQ7-6: 668.

More information

Vacuum Release Valve with Restrictor

Vacuum Release Valve with Restrictor INFORMATION Series SY3/5 Plug-in Only for External Pilot Vacuum Release Valve with Vacuum suction and release can be controlled with a single valve! PE Pilot EH port Flow rate adjustment of release air

More information

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1 Port Solenoid Valve Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Non plug-in manifold 0 0 S 60 Stations stations 0 stations SUP/EXH

More information

ISO Interface Solenoid Valve/SIZEq Metal Seal. Standard Specifications. Fluid Operating pressure. Ambient and fluid temperature

ISO Interface Solenoid Valve/SIZEq Metal Seal. Standard Specifications. Fluid Operating pressure. Ambient and fluid temperature ISO Interface Solenoid Valve/SIZEq Metal Seal SeriesVS7-6 VS7-6-FPG-D VS7-6-FG-D Accessories Mounting bolt (with washer) Packing Indicator Iight Optional Specifications VS7-6-FG-S Note: Please note that

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type20P 5 Port Solenoid Valve ody Ported Manifold ar Stock Type/Flat Ribbon Cable Series SY3000/5000/7000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 5 20P 05 Manifold series 3 SY3000

More information

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

Series VQZ1000/2000/3000 Single Unit

Series VQZ1000/2000/3000 Single Unit +- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body

More information

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04 Three functions (pressure regulator, switching valve, and speed controller) are provided by a single valve. The conventional valve combination circuit has been condensed into a single valve. A large capacity

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Rubber Seal Series VQ Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection Rubber Seal Port Solenoid Valve Series SJ000/000 Cassette Type Manifold 0 mm 7. mm (SJ000) 0 mm (SJ000) Non plug-in type Individual wiring manifold SJ000 SJ000 Can be mounted together. Connecter connection

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Port Solenoid Valve Metal Seal Rubber Seal Series Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

Example. U side. Stations SY5000

Example. U side. Stations SY5000 45 Type 5 ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN ail Mounted/Individual Wiring Series SY3000/5000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 3 45 05 U C6 Example

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type1P Type2P 5 Port Solenoid Valve ase Mounted Manifold ar Stock Type/Flat Ribbon Cable Series /5000/000 How to Order Manifold Type 1P/Compact style SS5Y 5 1P 05 C8 Manifold series 3 5, port size Thread

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

ISO Interface Solenoid Valve/SIZEq Metal Seal. Standard Specifications. Fluid Operating pressure. Ambient and fluid temperature

ISO Interface Solenoid Valve/SIZEq Metal Seal. Standard Specifications. Fluid Operating pressure. Ambient and fluid temperature ISO Interface Solenoid Valve/SIZq Metal Seal SeriesVS7-6 VS7-6-FPG-D VS7-6-FG-D Accessories Mounting bolt (with washer) Packing Indicator Iight Optional Specifications VS7-6-FG-S Note: Please note that

More information

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer Base Mounted Metal Seal/Rubber Seal VQ Built-in silencer, direct exhaust Space-saving profile All pilot valves are compactly mounted on one side. The space-saving design of mounting all fittings on one

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC)

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC) Port Solenoid Valve/Direct Poppet Rubber seal Series VK3000 Nl/min 147 Compact/Width 18 X Length 8 (mm) Low power consumption 4W DC (Standard) 2W DC (Energy saver) Standard copper free specification All

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series 1 Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

Rubber Seal VP300/500/700

Rubber Seal VP300/500/700 Port Pilot Operated Poppet Rubber Seal 00/500/700 High flow capacity Cv1.0 (00), Cv. (500), Cv.0 (700) Low power consumption: 1.8W(DC) Possible to use as either selector valve or divider valve Changeable

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

ISO Interface Solenoid Valve/SIZEq Metal Seal. Standard Specifications. Fluid Operating pressure. Ambient and fluid temperature

ISO Interface Solenoid Valve/SIZEq Metal Seal. Standard Specifications. Fluid Operating pressure. Ambient and fluid temperature ISO Interface Solenoid Valve/SIZq Metal Seal SeriesVS7-6 VS7-6-FPG-D VS7-6-FG-D Accessories Mounting bolt (with washer) Packing Indicator Iight Optional Specifications VS7-6-FG-S Note: Please note that

More information

5 Port Air Operated Valve

5 Port Air Operated Valve Port ir Operated Valve Series VF000/000/000 RoHS 22- Series VF000/000/000 Model Selection by Operating Conditions q ir Operated Valve: Single Unit Series Sonic conductance C[dm /(s bar)] Type of actuation

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes

More information

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control Port Electro-Pneumatic Proportional Valve Series 000/000 Capable of actuating a cylinder and performing analog control of pressurization alone can be used to switch and actuate a cylinder and to perform

More information

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000 D-sub Connector J Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000//000 Number of connectors: pins MIL-C-08 Conforming to JIS-X-0 --6 For details

More information

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Vacuum Release Valve with Restrictor Series SJ3A6 SJ Plug-in Type Connector Connection P.86 D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Non Plug-in Type Individual

More information

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector

More information

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308 Cable ppendix Cable ppendix Multi-way cables The multi-pole connector cables used on SMC valves are common across several ranges. Cables are available in accordance with the MIL standard C-08 and also

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to

More information

Series SY3000/5000 How to Order Manifold

Series SY3000/5000 How to Order Manifold Type N ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN Rail Mounted/Connector ox SY/ How to Order Manifold SSY SY SY Specifications Symbol Specifications With connector box (COM spec.) N With

More information

3 Port Air Operated Valve

3 Port Air Operated Valve Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation

More information

5 Port Solenoid Valve Plug Lead Type

5 Port Solenoid Valve Plug Lead Type 5 Port Solenoid alve Plug Lead Type Series Body Ported Flow rate characteristics For single/double solenoid C [dm 3 /(s bar)]: 0.6 Single Unit alve width: 7.4 mm Possible to drive cylinders: Up to ø32

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A Type N SY/ ase ounted anifold Stacking Type/DIN Rail ounted Connector ox How to Order anifold SSY SY SY Specifications Symbol Specifications With connector box (CO spec.) N With connector box ( CO spec.)

More information

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing

More information

5 Port Air Operated Valve. Specifications. Flow characteristics 1 4/2(P A/B) Cv

5 Port Air Operated Valve. Specifications. Flow characteristics 1 4/2(P A/B) Cv 5 Port Air Operated Valve Series 000 Model (With sub-plate) Valve model -M5 -M5 3-M5 -M5 --0 --0 --0 --0 3--0 3--0 --0 --0 position 3 position position 3 position Type of actuation Single Double Closed

More information

Single Valve/Sub-plate Type IP67 Compliant 90-SV Series

Single Valve/Sub-plate Type IP67 Compliant 90-SV Series Single Valve/Sub-plate Type IP7 Compliant -SV Series SV 00 W U aterial restriction Series -SV000 -SV000 Thread type c F G N NPT T NPTF A B SOL.a SOL.a Type of actuation position single (EA) (P)(EB) position

More information

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring Type4 SY000/000 ase Mounted Monifold Stacking Type/DIN ail Mounted Individual Wiring How to Order Manifold SSY 4 0 U C6 How to Order Valve Manifold ssembly Ordering example SY000 SY000 Valve stations 02

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

Series SYA3000/5000/7000

Series SYA3000/5000/7000 1 Port Air Operated Valve Series SYA000/000/7000 Body ported Base mounted Base mounted How to Order A, B port size Thread type Thread piping (Inch size) Nil Rc Symbol Port size Applicable series Symbol

More information

New Concept Connector Type Manifold

New Concept Connector Type Manifold New Concept Connector Type Manifold Series /000/3000/000 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration.

More information

VQ1000. How to Order Manifold. Kit type

VQ1000. How to Order Manifold. Kit type - - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold

More information

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot 3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in

More information

Terminal Block Box (Spring Type) SY3000/5000/7000 Series

Terminal Block Box (Spring Type) SY3000/5000/7000 Series INFORMATION 5 ort olenoid alve Terminal lock ox (pring Type) Y3000/5000/7000 eries Compact RoH Height 6.7 mm shorter (Approx. 9% reduction) Installation area of the terminal block box Reduced by approx.

More information

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Series 000 Compact and lightweight: 3 mm width Compact yet provides

More information

5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type. Closed Center DS3330/DS3300. How to Order - Body Ported Type

5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type. Closed Center DS3330/DS3300. How to Order - Body Ported Type 5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type COMPACT SIZE AND LIGHT WEIGHT LARGE FLOW CAPACITY LOW POWER CONSUMPTION DESIGNED FOR NON-LUBRICATED SERVICE DV000 Symbol Single DS330/ How

More information

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal Port Solenoid Valve Cassette Type Manifold Rubber Seal 7.mm (SJ000) SJ000 SJ000 Can be mounted together. 0mm (SJ000) Connector connection New New cable type manifold is added! New Additional options are

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Rubber Seal Port Solenoid Valve Series Manifold Single Unit ase Mounted Manifold VV01 V100 ar base P.18 ody Ported P.10 ase Mounted P.10 VQD VKF VK VT VS Separable base ody Ported Manifold P.1 Stacking

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

0.35 W (Without light)

0.35 W (Without light) Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:

More information

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control Port Electro-Pneumatic Proportional Valve Series VER000/000 Capable of actuating a cylinder and performing analog control of pressurization VER alone can be used to switch and actuate a cylinder and to

More information

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating / ort Solenoid Valve ubber Seal Series SYJ000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Specifications JIS Symbol port port (manifold) position

More information

3, 5 port pilot operated valve Pneumatic valve / master valve. Discrete valve. Manifold

3, 5 port pilot operated valve Pneumatic valve / master valve. Discrete valve. Manifold K/K, pilot operated valve neumatic valve / master valve MNE0 MNE0 M MN W WG MNS0 MNS0 T L-/ S/0 S/ K/ F CONTENTS Safety precautions 776 Discrete valve ody ing (K/K to ) 868 Sub-plate ing (K to ) 87 Manifold

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve ubber Seal / ort Solenoid Valve Series 000 / 000 / 000 [Option] SJ SY SV SZ V S000 VQ VQ VQ VQC VQZ SQ VFS VF VQ Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread

More information

CAT.E152-5 Port Solenoid Valve/Body Ported Cassette Type Manifold. Series SZ3000

CAT.E152-5 Port Solenoid Valve/Body Ported Cassette Type Manifold. Series SZ3000 CAT.E- Port Solenoid Valve/Body Ported Cassette Type Manifold Series SZ000 The plug-in cassette system makes valve replacement easy. A plug-in manifold has been realized having a manifold height of.mm

More information

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve CT.E- ase Mounted Type Series VQ Port Metal Seal/Rubber Seal Solenoid Valve dvanced manifold va the new age of factory au ase Mounted Type Space saving profile Clean space saving design with all pilot

More information

Series SV1000/2000/3000/4000

Series SV1000/2000/3000/4000 Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double

More information

Series SYA3000/5000/7000

Series SYA3000/5000/7000 Port Air Operated Valve Series SYA000/000/7000 How to Order A, B port size Thread type Thread piping (Inch size) - Rc Symbol Port size Applicable series Symbol Port size Applicable series F G SYA000 N

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information