Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Size: px
Start display at page:

Download "Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated."

Transcription

1 Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control setting and multiple steps pressure control Air operated Specifications Operation type Fluid Max. operating pressure Set pressure Air operated range Solenoid Ambient and fluid temp. Hysteresis Repeatability Sensitivity Mounting Lubrication Port 0 Port size 8 (R) Weight (kg) Pilot Solenoid Valve Specifications Model Pilot valve Electrical entry Model Air operated Solenoid Air operated, External pilot solenoid Air.0 MPa 0.05 to 0.9 MPa 0.05 to 0.7 MPa 0.05 to 0.9 MPa 0 to 50 C (Air operated: 0 to 60 C) No condensation 0.0 MPa 0.0 MPa 0.0 MPa Free Not required (Use turbine oil Class ISO VG, if lubricated.) / 0 / 0 50 / 70 / 90 VK4- VO07K- Grommet, DlN terminal Grommet, DIN terminal Coil rated voltage (V) AC(50/60Hz) DC 00 V, 0 V, 00 V, 0 V, 40 V V, 4 V Allowable voltage ±0% of rated voltage 5 to +0% of rated voltage Apparent AC Inrush 9.5 VA/50 Hz, 8 VA/60 Hz.7 VA (50 Hz), 0.7 VA (60 Hz) Holding 7 VA/50 Hz, 5 VA/60 Hz 7.6 VA (50 Hz), 5.4 VA (60 Hz) power DC 4 W (Without indicator light), 4. W (With indicator light) 4 W (Without indicator light), 4. W (With indicator light) Non-locking push type Note) Non-lubricated specifications are not available for this product Symbol Air operated P (R) External pilot solenoid External pilot solenoid P P (R) Option Description Bracket (With bolt and washer) Pressure gauge Note) B F G A -8-A G7-0-0 Part no A 5-A 7-A 9-A G6-0-0 G Note) When requiring a gauge different than that mentioned above, specify the model number. Option is packed with it. (Refer to Best Pneumatics No. 7.) Example: 00-0 G6-4-0 P P (R) 740

2 Power Valve: Regulator Valve Series Regulator valve T NPTF Note ) Not conforming to ISO79-. How to Order 0 0 D B Operation type 0 Air operated External pilot solenoid Thread type Nil F N Rc G () NPT Rated voltage (Only with solenoid) 00 VAC (50/60 Hz) 00 VAC (50/60 Hz) 0 VAC (50/60 Hz) 4 0 VAC (50/60 Hz) 5 4 VDC 6 VDC 7 40 VAC (50/60 Hz) For other rated voltages, please consult with SMC. Option Nil B Bracket F Foot (0 only) G Gauge When specifying more than one option, combine symbols alphabeticaly. Light/Surge voltage suppressor (Only with solenoid) Nil S Z Sub-plate and gasket part no. Sub-plate With surge voltage suppressor With light/surge voltage suppressor 9 P Port size Symbol Port size A /8 B /4 Base gasket Thread type Symbol Thread type Nil Rc F G N NPT T NPTF Body size Port size Electrical entry (Only with solenoid) Body size Body ported Base mounted Port size Port, (R) Nil Without sub-plate Electrical entry (Only with solenoid) G: Grommet (00 mm) H: Grommet (600 mm) D: DIN terminal DO: DIN terminal (Without connector) G: Grommet (00 mm) H: Grommet (600 mm) D: DIN terminal G: Grommet (00 mm) H: Grommet (600 mm) D: DIN terminal DO: DIN terminal (Without connector) Light/Surge voltage suppressor (Only with solenoid) Nil S Z Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages to 9 for /4/5 Port Solenoid Valve Precautions. 74

3 Series Application Example. Relief regulator (Rapid tank internal pressure setting) (Relieving type regulator e.g. AR000) TANK P (R) Relieving type diaphragm regulator P P (R) Large exhaust capacity. Silencer is easy to connect.. Air blow (As port directional control regulator valve) (AR000, etc.) P (R) 5. steps directional control setting P P (R) 6. Multiple steps pressure control (Toward stepless control) (R) P P P P (R) VALVES IN ONE A simple main system is ensured. Remotely controlled by compact pilot system. Air motor, etc. External pilot port solenoid valve (For on/off operation) Diaphragm regulator (For pressure setting) Solenoid on/off operation controls the air flow. Setting can be changed by remote control. (Remote control). Constant pressure supply and driving (As port directional control regulator valve) Note) The pressure is about 0.0 MPa when OFF because of leakage. (R) n P P (R) The main driving system is simple consisting of one only. Remotely controlled by compact pilot system. (R) (Solenoid valve) (Regulator) (R) (R) 4. Balance and driving (R) (External pilot (Relieving type solenoid valve) regulator) P P P P (R) Actuator s appropriate pressure control saves energy (Air). P (R) Actuator driving system becomes simple. P (R) The large capacity relief valve rapidly responds and sets the balance pressure. Solenoid on/off operation drives the cylinder. Common exhaust. P (R) Steplessly and remotely controlled by electric signals. Flexibile pressure control for welders. When the outlet side capacity is small, install a speed controller AS000, in the pilot pipe to lower the pilot pressure for vibration prevention. (Meter-in) ((5) steps directional control setting, (6) multiple steps pressure control setting) Relieving type regulator such as AR000, etc. should be used as pilot regulator in the application.(when the non-relieving type is used, pressure cannot be changed from high to low.) A sensitive regulator such as the ARP0, etc. should be used as a pilot regulator on the low pressure side, particularly with 5. steps directional control setting and 6. multipje steps pressure control. (Using a non-sensitive regulator may cause unstable pressure.) 74

4 Power Valve: Regulator Valve Series Flow Rate Characteristics 0 / 0 Port pressure (MPa) Port pressure.0 MPa 90 Port pressure (MPa) Port pressure.0 MPa 0 (Relief exhaust) Air flow rate (Reduced pressure supply) (Relief exhaust) Air flow rate (Reduced pressure supply) Port pressure (MPa) Port pressure.0 MPa Setting Pressure Characteristics Port P pressure is set according to port pressure (Relief exhaust) Air flow rate (Reduced pressure supply) Port Port pressure (MPa) pressure.0 MPa Port presure (MPa) Port P pressure (MPa) 70 (Relief exhaust) Air flow rate (Reduced pressure supply) Port pressure (MPa) Port pressure.0 MPa External Pilot Piping Port side (Relief exhaust) Air flow rate (Reduced pressure supply) Port, (R) side Port side Port, (R) side Port 00 0 P External pilot External pilot P () Pilot exhaust Note ) Port P is not compatible with 00. Note ) A silencer is mounted to port P for /5/7/9 0 as a standard. For the steps directional control and multiple steps pressure control setting, use the product after removing a silencer. Port side 74

5 Series Pressure Characteristics Shows the outlet pressure (Port ) change against the inlet pressure (Port (p)) change. They conform to JIS B 87 (Air pressure regulator) / 0 Port presure (MPa) Set point Port presure (MPa) Set point Port pressure (MPa) 0 Port pressure (MPa) Relief Time. Relief time from 0.5 MPa to 0. MPa Port presure (MPa) Set point Relief time (S) Port pressure (MPa) 50 Port presure (MPa) Set point Tank size (L). Relief time from 000 L tank 70 Port pressure (MPa) Pressure (MPa) Port presure (MPa) 744 Port pressure (MPa) Set point. Relief time from an arbitrary pressure [Example] 500 lowers 000 L tank from 0.4 MPa to 0. MPa: a) In graph. Initial pressure Desired low pressure Relief time From above, the relief time is 6 = s Relief time (S) b) The relief time for the 000 L tank is found by conversion as shown below. Tank capacity Relief time t = x 000 that is read 000 = x 000 = 46 The result is 46 s.

6 Power Valve: Regulator Valve Series Construction/Working Principle/Component Parts () When Port pressure is high Relief exhausting () Setting pressure condition () When Port pressure is low Pressure reducing supply The balance between the acting force F of the pilot pressure (port P) over the upper surface of the pressure regulating piston and the acting force F of the pressure at port leading to a space under the piston through the feed back flow root closes a couple of poppet valves 6 and sets port pressure that corresponds to port P pressure. The poppet valves are backed up by spring 4 - in the pressure balance structure by means of port pressure. (DRW ()) When port pressure exceeds port P pressure, F becomes larger than F, and the pressure regulating piston moves upward, opening the upper poppet valves. Thus air is released from port to port (R) (DRW ()). When port pressure lowers enough to restore the balance with port P pressurs, the regulator valve returns again to the DRW () condition. When port pressure is lower than port P pressure, F becomes larger than F, and the pressure regulating piston moves downwards, opening the lower poppet valves. Thus air is supplied from port P to port (DRW ()). When port pressure rises enough to restore the balance with port P pressure, the regulator valve returns again to the DRW () condition. (Air operated) 00 Port P (Air operated) 00/500/700/900 Feedback Port P Port (R) Port Feedback Port Port (R) (Air operated) 00 Feedback Port Port Port Sub-plate Port Port (R) Port No. Description Material Body Cover Regulation piston Aluminum alloy casted Aluminum alloy casted Aluminum alloy 4 Spring Stainless steel 5 Valve guide Aluminum alloy 6 Poppet valve Aluminum alloy, Rubber 7 Shaft Stainless steel 8 Valve guide Aluminum alloy 745

7 Series Dimensions Air operated: 00 External pilot solenoid: (DIN terminal) Pressure gauge (Option) Lead wire length 00 (Grommet: G) Applicable cable O.D ø.5 to ø7 60 (Air operated) 88.5 (Grommet) (DIN connector) M5 B: Bracket F: Foot x /8, /4 Air operated x ø4.5 (Mounting thread) x M Thread depth 6.5 (For bracket, foot mounting) 4 x ø4.5 (Mounting hole) Air operated: 00 External pilot solenoid: (DIN terminal) x ø4.5 (Mounting hole) Pressure gauge (Option) M5 Applicable cable O.D ø.5 to ø (DIN terminal) 87 (Grommet) How to Use DIN Terminal Refer to page 48 for VK00 series. 746 x /8, /4 Air operated

8 Power Valve: Regulator Valve Series Dimensions Air operated: 00 External pilot solenoid: 0 (Silencer) Silencer 0 only 78 (Air operated) Pressure gauge (Option) 78.5 (DIN terminal) G: Grommet 00 (Lead wire length) Silencer 0 only Applicable cable O.D ø.5 to ø7 D: DIN terminal Bracket (Option) (Bracket mounting hole) 4 x M5 Thread depth 8 (For bracket mounting) x /4, /8, / How to Use DIN Terminal Refer to page 48 for VK00 series. Air operated: 500 External pilot solenoid: 50 Bracket (Option) P. Pressure gauge (Option) P (08.5) G: Approx. 00 H: Approx. 600 (Lead wire length) 47.6 (Grommet) 45 Applicable cable O.D. ø6 to ø8 Plug (/8) A R DIN terminal (D) Grommet (G) P (DIN terminal) MAX.0 Pg9 /4 MAX (Air operated) /4 (For 50 only) [Silencer (AN0-0) Standard] x M6 x Thread depth 9 (For bracket mounting) x ø9 (Mounting hole) How to Use DIN Terminal Refer to page 45 for VT07 series. x /, /4,

9 P P Series Dimensions Air operated: 700 External pilot solenoid: 70 P. Pressure gauge (Option) P (.5) G: Approx. 00 H: Approx. 600 (Lead wire length) 6.6 (Grommet) 5 Applicable cable O.D. ø6 to ø8 Plug (/8) A R P Bracket (Option) DIN terminal (D) Grommet (G) (DIN terminal) MAX.0 Pg9 /4 MAX. 96 (Air operated) 8. 5 /4 (For 70 only) [Silencer (AN0-0) Standard] 4 x M6 x Thread depth 6 (For bracket mounting) 8 x ø9 (Mounting hole) 49 / x, / Air operated: 900 External pilot solenoid: 90. Pressure gauge (Option) (5.5) G: Approx. 00 H: Approx. 600 (Lead wire length) Applicable cable O.D. ø6 to ø8 Plug (/8) Bracket (Option) DIN terminal (D) Grommet (G) MAX.0 Pg9 /4 MAX. 8.8 /4 (For 90 only) [Silencer (AN0-0) Standard] 4 x M6 x Thread depth (For bracket mounting) 5 (Grommet) A R P (DIN terminal) (Air operated) x ø7 (Mounting hole) 0 How to Use DIN Terminal Refer to page 45 for VT07 series x /,

10 Series Manifold Specifications Specifications Valve stations to 8 () Port specifications Common SUP, EXH Port size (Port,, (R)) Rc, NPTF, G, NPT 4 Applicable valve 00/0 () Applicable blanking plate -7 (With gasket and bolts) Note ) If there are more than 5 stations, apply pressure from port on both sides and exhaust from port (R) on both sides. Note ) 00 (air operated) and 0 (external pilot solenoid) are both individual external pilot type. The port P on the valve is used as a pilot port, but not the P hole on the manifold base. External Pilot Piping Type Air External pilot Valve port operated solenoid valve Applicable valve 00 0 P External pilot External pilot P Note) Pilot exhaust Note) Port P is not available for 00 How to Order Series Manifold V 6 Valve stations stations 8 8 stations 0 Thread type Nil Rc F G () N NPT T NPTF Note ) Not conforming to ISO79-. P, A, R port size 0 4 How to Order Manifold Specify the part numbers for the regulator valve and blanking plates starting from the left of manifold base (After making the port face the front). (Ex.) V--5-0N 5 station manifold base, Port thread NPT 0-5DZ-G 4 Regulator valve, External pilot solenoid valve, 4 VDC, DIN terminal, with light/surge voltage suppressor, Option with pressure gauge Note) -7 Blanking plate Note) In the case of manifold, pressure gauge: G7-0-0 only (O.D. ø6) Dimensions V--- Station -0 Non-locking push M5 (P, P) x ø6.5 Mounting hole Pressure gauge (Option) G7-0-0 Mounting example Port : /4 Pilot port Exhaust port n x port : /4 Port (R): /4 n L L L n: Station Formula L = x n + 9 L = x n

11 (R) A large capacity system without connection loss. (R) P = 0.7 (Valves and piping can be made smaller.) ) ( ) ( ) ( Terminal deceleration and an intermediate speed change circuit can be produced easily. The simple system configuration permits sharp response. The large capacity system configuration without connection loss allows the use of smaller valves and piping. For example, when solenoid (b) of valve is turned off while the cylinder is extending, the exhaust port closes and cylinder movement decelerates. Power Valve: Position Valve Series Realize a variety of circuits using simple components. Current system configuration Intermediate and emergency stops of large-sized cylinders Intermediate and emergency cylinder stops The position closed center valve produces a simple and large capacity system. = 0.58 )( )( )( (Emergency stop valve) )( There were not many suitable large capacity 5 support valves available with a position closed center. Vacuum suction and release The port, position double solenoid that permits vacuum suction, release, and suspension (closed) is ideal for a system where many valves are used. Suction filter Vacuum pad There were not many suitable -port valves for stopping. Pressurized air (R) Vacuum pump P (R) The body sizes ///4 have been remodeled. For details, refer to page 7. System configuration when using A (Speed change valve) (Switching valve) Universal porting could be used as a selector/ divider valve The pressure balancing poppet valve that permits any flow direction allows sequential switching operation, preventing blow by and air entrainment. Two-stage directional control selection Direction divider Stroke Stroke Time Time There is no blow-by when switched from vacuum suction to vacuum release or vice versa. When maintaining the vacuum of port, the vacuum may decrease due to leakage from the vacuum pad or piping. Conduct vacuum suction at the vacuum adsorption position. Furthermore, it cannot be used as an emergency cutoff valve. For operation control of double acting cylinders Two power valves driven by a double acting cylinder allows operation control in 9 positions ( positions x positions = 9 positions) including slow stopping, acceleration, and deceleration. x = 9 positions B N A Reciprocation Pressure center Closed center Exhaust center Pressure & closed center Exhaust & closed center b n a Slow stopping or decelaration This valve is not a non-leak specification, and thus cannot be used for long term intermediate stops or emergency stops. 75

12 Series Cylinder Speed Chart Please assume the chart is offered as the guideline. For details about various each condition, please make use of SMC Model Selection Software and then decide it. Bore size Average MB, CA series CS/CS series System velocity Pressure 0.5 MPa, Load factor 50% Pressure 0.5 MPa, Load factor 50% (mm/s) Cylinder stroke 500 mm Cylinder stroke 00 mm ø40 ø50 ø6 ø5 ø40 ø60 ø80 ø00 ø80 ø00 ø50 ø00 A B C D E F Vertically upward movement Horizontal movement When the cylinder is extended, the speed controller is metered-out, is connected with the cylinder directly, and its needle is fully open. Values on the average velocity of a cylinder are obtained from the stroke length divided by full stroke time. Load proportion is ((load weight x 9.8)/theoretical force) x 00% 75

13 Power Valve: Position Valve Series Bore size Average MB, CA series CS/CS series System velocity Pressure 0.5 MPa, Load factor 50% Pressure 0.5 MPa, Load factor 50% (mm/s) Cylinder stroke 500 mm Cylinder stroke 00 mm ø40 ø50 ø6 ø5 ø40 ø60 ø80 ø00 ø80 ø00 ø50 ø00 G H I J Vertically upward movement Horizontal movement K 000 System A B C D E F G H I J K When the cylinder is extended, the speed controller is metered-out, is connected with the cylinder directly, and its needle is fully open. Values on the average velocity of a cylinder are obtained from the stroke length divided by full stroke time. Load proportion is ((load weight x 9.8)/theoretical force) x 00% Conditions of Speed Chart Solenoid valve Speed controller AS AS40-0 AS40-04 AS40-04 AS AS600-0 AS600-0 AS800- AS900-4 AS900-0 Silencer AN0-0 AN0-0 AN40-04 AN40-04 AN AN600-0 AN600-0 AN700- AN800-4 AN900-0 Tubing diameter x Length ø0 x m ø x m ø x m SGP5A x m SGP5A x m SGP0A x m SGP5A x m SGP5A x m SGPA x m SGP40A x m SGP50A x m 75

14 Series How to Order The body sizes ///4 have been remodeled. For details, refer to page 7. Body size Port size Body size 0 Port size 8 Port 0, 4 (R) Electrical entry (Only with solenoid) Body size Symbol G H L LN LO M MN MO D DO G H D Electrical entry (Only with solenoid) Grommet, Lead wire length 00 mm Grommet, Lead wire length 600 mm L plug connector, Lead wire length 00 mm L plug connector, Without lead wire L plug connector, Without connector M plug connector, Lead wire length 00 mm M plug connector, Without lead wire M plug connector, Without connector DIN terminal DIN terminal, Without connector Grommet, Lead wire length 00 mm Grommet, Lead wire length 600 mm DIN terminal Electrical entry (Only with solenoid) Nil S Z Body ported D B Base mounted D B 0 Operation type Body size Port size Body size Port size Port, (R) Nil Without sub-plate Nil Without sub-plate Note ) Not conforming to ISO79-. Sub-plate and base gasket part no. Valve size Air operated External pilot solenoid Internal pilot solenoid Thread type Nil Rc F G () N NPT T NPTF Rated voltage (Only with solenoid) VAC (50/60 Hz) 00 VAC (50/60 Hz) 0 VAC (50/60 Hz) 0 VAC (50/60 Hz) 4 VDC VDC 40 VAC (50/60 Hz) For other rated voltages, please consult with SMC. Option (Only bracket or foot may be mounted.) Nil B Bracket () F Foot ( and only) N Silencer for pilot exhaust port (Only with solenoid) Note) Except, and 4 Light/Surge voltage suppressor Nil S With surge voltage suppressor (Grommet only for a body size of 50 or more) Z With light/surge voltage suppressor (Except grommet) Electrical entry () (Only with solenoid) Symbol Nil Grommet, Lead wire length 00 mm Grommet, Lead wire length 600 mm L plug connector, Lead wire length 00 mm L plug connector, Without lead wire L plug connector, Without connector G H L LN LO M MN MO D DO Electrical entry (Only with solenoid) M plug connector, Lead wire length 00 mm M plug connector, Without lead wire M plug connector, Without connector DIN terminal DIN terminal, Without connector Electrical entry (Only with solenoid) S Z Note ) Refer to page 768 for individual part numbers of plug and DIN connectors. (Common with VZ series) 4 9 P 4 A P Sub-plate Symbol A B Port size Port size /8 /4 Symbol Nil F N T Thread type Thread type Rc G NPT NPTF Port size Symbol Port size A /8 B /8 C / Thread type Symbol Thread type Nil Rc F G N NPT T NPTF Base gasket 4 4 Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages to 9 for /4/5 Port Solenoid Valve Precautions. 754

15 Power Valve: Position Valve Series Variety of circuits in simple construction position valve suitable for intermediate and emergency stop of large size cylinder. System construction with Current system construction There were not many suitable large capacity 5 port valves available with a position closed center. There were not many suitable large capacity port valves available for stopping operations. Specifications Body ported Model Base mounted Operation type Air operated, External pilot solenoid, Internal pilot solenoid Fluid Air Air operated Main pressure Low vacuum to.0 MPa External pilot pressure 0. to.0 MPa Main pressure Low vacuum to.0 MPa Pressure External pilot External pilot pressure range solenoid External pilot pressure 0. to 0.9 MPa 0. to 0.7 MPa Internal pilot solenoid Ambient and fluid temperature Response Pilot pressure time 0.5 MPa Main pressure 0. to 0.7 MPa 40 ms or less Main pressure 0. to 0.9 MPa 0 to 50 C (Air operated 60 C) 60 ms or less Max. operating frequency Mounting cycles/sec. Free Lubrication Not required (Use turbine oil Class ISO VG, if lubricated.) Note) Non-lubricated specifications are not available for this product. Pilot Solenoid Valve Specifications Pilot valve Model Electrical entry Coil rated voltage (V) AC(50/60Hz) DC Temperature rise Apparent Inrush power AC Holding Power consumption DC,,, 4,,, 4 50, 70, 90 50, 70, 90 Exclusive pilot valve VO07K- Grommet, L plug connector, Grommet, Grommet terminal, M plug connector, DIN terminal Conduit terminal, DIN terminal 00V, 0V, 00V, 0V, 40V 6V, V, 4V, 48V 5 to +0% of rated voltage 4.5 VA/50 Hz, 4. VA/60 Hz.7 VA (50 Hz), 0.7 VA (60 Hz).5 VA/50 Hz, VA/60 Hz 7.6 VA (50 Hz), 5.4 VA (60 Hz).8 W (Without indicator light),. W (With indicator light) 4 W (Without indicator light), 4. W (With indicator light) Non-locking push type Non-locking push type Note) When replacing the pilot valves specified for valve sizes to 4, please request SMC to replace them at the factory. Symbol Air operated Internal pilot solenoid/external pilot solenoid a P a Option Bracket (With bolt and washer) Foot (With bolt and washer) Pilot exhaust port P silencer Note) Weight Description B -8-A F N Note) Only with solenoid. Model Air operated Solenoid A AN0-M5 --A Part no A 7-A 9-A AN (kg) (R) (R) (R) b b Air operated External pilot solenoid Internal pilot solenoid 755

16 Series Flow Rate Characteristics Model Body ported Base mounted 4-0 (With sub-plate) Port size /8 /4 /4 /8 / / /8 /4 /4 /8 / Flow rate characteristics (R) (R) C[dm /(s.bar)] b Cv C[dm /(s.bar)] b Cv C[dm /(s.bar)] b Cv C[dm /(s.bar)] b Cv Body ported Model Port size /4 /4 / Effective area (mm ) Cv External Pilot Piping Port 0 P P External pilot External pilot External pilot Pilot exhaust Plug Pilot exhaust Port side 0 Air operated External pilot solenoid Port side Internal pilot solenoid 4(Solenoid) When the 40 air operated power valve is delivered from our factory, the M5 threaded pilot port P in the cover is open and the /8 pilot port in the sub-plate is plugged. When port P on the body Note) is used as a pilot exhaust port, remove the /8 plug and put the M5 plug into the pilot valve port P to cover it. Note) Body for, sub-plate for 4 Port, (R) side Port, (R) side Port, (R) side 40 Air operated for sub-plate 4 External pilot solenoid for subplate 4 Internal pilot solenoid for subplate Cover Cover Sub-plate Plug (/8) Sub-plate Plug (/8) 756

17 Power Valve: Position Valve Series Body Ported: Air operated: 0 External pilot solenoid: Internal pilot solenoid: x M Thread depth 6.5 (For bracket, foot mounting) 4 x ø4.5 (Mounting hole) DlN terminal (D) Foot F (Option) Hexagonal socket Spring washer Silencer (Option: N) (Except 0) A perspective drawing Table () With/Without Plug for M5 Port Model 0 P With plug P M plug connector (M) L plug connector (L) M5 Refer to Table (). Non-locking push 60 (Air operated) M5 Refer to Table (). Bracket B (Option) x /8, /4 x ø4.5 mounting hole Hexagonal socket Spring washer How to Use Plug Connector/Applicable Model: / / /4 Attaching/Detaching of a plug. To install the connector Push the connector straight on the pins of the solenoid, making sure the lip of the lever is securely positioned in the groove on the solenoid cover.. To deinstall the connector Press the lever against the connector and pull the connector away straight from the solenoid. L type Mode coil Groove Pin Cover M type Lever DC indicator Socket DXT70-7- Pin Connector Cover Hook Red Black DC coil: + red, black Lead wire 0. to 0. mm (Max. O.D.: ø.7 mm) Crimping lead wire and socket Peel. to.7 mm of the tip of the lead wire, enter the core wires neatly into a socket and press contact it with a press tool. Be careful so that the cover of lead wire does not enter into the core press contacting part. (Please contact SMC for the dedicated crimping tools.) Core wire Crimping crimping area area Core wire Terminal Lead wire Hook Insulation Attaching/Detaching of a socket with lead wire. Attaching Insert a socket into the square hole (indicated at +, ) of connector, push fully the lead wire and lock by hanging the hook of a socket to the seat of connector. (Pushing in can open the hook and lock it automatically.) Then confirm the locking by lightly pulling on the lead wire.. Detaching For pulling out a socket from connector, pull out the lead wire while pushing the hook of a socket with a stick with a fine point ( mm). If a socket is to be re-used as it is, return the hook to the outside. Socket Hook Connector Lead wire 757

18 Series Base Mounted: Air operated: 0 External pilot solenoid: x /4, /8 Internal pilot solenoid: DlN terminal (D) Max (Air operated) x ø4.5 (Mounting hole) M5 Refer to Table (). (Solenoid valve) L plug connector (L) M plug connector (M) Table () With/Without Plug for M5 Port Model 0 P With plug P M5 Refer to Table (). Sub-plate Refer to page 754. Silencer AN0-M5 (Option: N) (Except 0) How to Use DIN Terminal Refer to page

19 Power Valve: Position Valve Series Body Ported: Air operated: 0 External pilot solenoid: Internal pilot solenoid: x M5 Thread depth 7 (For foot mounting) 4 x ø6 mounting hole DlN terminal (D) Max. 0 Foot F; --A (Option) {Hexagonal socket head cap screw (with spring washer)} A perspective drawing Table () With/Without Plug for /8 Port Model 0 P P With plug With plug With plug Silencer AN0-M5 (Option: N) (Except 0) M plug connector (M) L plug connector (L) Sol. a Sol. a Non-locking push x /4, /8, / Refer to on page (Air operated) x ø5.5 mounting hole 759

20 Series Base Mounted: 4 Air operated: 40 External pilot solenoid: 4 Internal pilot solenoid: 4 x /4, /8, / DlN terminal (D) Max (Air operated) M5 Pilot port (40 only) (Solenoid) x ø5.5 mounting hole Table () With/Without Plug for Sub-plate Model P P With plug With plug With plug With plug With plug L plug connector (L) M plug connector (M) Sub-plate Silencer AN0-M5 (Option: N) (Except 40) M5 Plug (/8) Refer to Table (). Refer to on page

21 Power Valve: Position Valve Series Body Ported: 50/70 Air operated: 500 External pilot solenoid: 50 Internal pilot solenoid: 50 SOL.a SOL.b Bracket (Option) P G: Approx. 00 H: Approx. 600 (Lead wire length) P A R Grommet (G) MAX. P Air operated: 700 External pilot solenoid: 70 Internal pilot solenoid: 70 Table () With/Without Plug for /4 Port Model P With plug P P P.. MAX (Grommet) (DIN terminal) Pg9 6 7 Applicable cable O.D. ø6 to ø8 DIN terminal (D) /4 (Plug) Refer to Table (). 07 (Air operated) 96 5 /4 Silencer (Option) (Except 500) 9 x M6 x Thread depth 9 (For bracket mounting) x ø9 (Mounting hole) x /, /4, SOL.a SOL.b Bracket (Option) G: Approx. 00 H: Approx. 600 (Lead wire length) MAX.0 8. A R Grommet (G) MAX. P 05 (DIN terminal) Pg Applicable cable O.D. ø6 to ø8 DIN terminal (D) 6.6 (Grommet) 5 96 (Air operated) 49 /4 (Plug) Refer to Table (). 5 /4 Silencer (Option) (Except 700) 8 4 x M6 x Thread depth 6 (For bracket mounting) x ø9 (Mounting hole) / How to Use DIN Terminal Refer to page 45 for VT07 series. x, /

22 P P Series Base Mounted: 90 Air operated: 900 External pilot solenoid: 90 Internal pilot solenoid: 90 SOL.a SOL.b P Bracket (Option). 6 Table () With/Without Plug for /4 Port Model 900 P P P With plug G: Approx. 00 H: Approx. 600 (Lead wire length) Applicable cable O.D. ø6 to ø8 DIN terminal (D) Grommet (G) MAX. MAX.0 Pg9 /4 (Plug) Refer to Table (). 96. /4 Silencer (Option) (Except 900) 4 x M6 x Thread depth (For bracket mounting).6 (Grommet) 8.4 A R P 6 (DIN terminal) 54 8 (Air operated) x ø7 (Mounting hole) x /, How to Use DIN Terminal Refer to page 45 for VT07 series. 76

23 Series Manifold Specifications Manifold: V Series Specifications Model V V4 Applicable valve 0/ 40/4 Valve stations Note) to 8 to 6 Port specifications Common SUP, EXH Pilot type Internal pilot, Common external pilot Common external pilot port size M5 x 0.8 Length of thread 5 Port size (R) Applicable blanking plate (With gasket, screw) (With gasket, screw) Note) When V series is used with more than 5 stations, or V4 series is used with more than 4 stations, apply pressure to the port on both sides and exhaust from the port (R) on both sides. Common External Pilot Piping V- V4- (P: M5 plug) (P: M5 plug) P: Pilot exhaust port P: Common external pilot port P: Pilot exhaust port P: Common external pilot port V 6 How to Order Manifold Base 0 Thread type Body size Pilot type Valve stations Port size Body size Pilot type Applicable valve Valve Port size stations Port (R) Internal pilot Air operated: Common external pilot 0 Note) 8 8 Internal pilot 4 A Air operated: B 8 Common external pilot 40 Note) 6 6 C 8 Nil N F T Rc NPT G FNPT Note) Air operated 0 and 40 (air operated) are used. Distinction between the pilots (internal or extertal pilot) of the manifold base does not matter. Either may be used. Example for ordering a manifold base: The valve and blank plate for manifold arrangement should be specified in order from the left side of the manifold base (with the port on your side). (Example) V--7-0N -LN 6 pcs. Solenoid -7 pc. V4--6-A 40 5 pcs. Air operated 4-5 pc. manifold (Size, 4) Pilot type Manifold pilot type Air operated type Internal pilot type Common external pilot type Individual external pilot type Manifold part no. V--- V--- V--- V--- Applicable valve part no. 0/40 /4 /4/4 Note) If external pilot types are used, the common external pilot type is recommended. Operating pressure range Low vacuum to.0 MPa 0. to 0.7 MPa Low vacuum to.0 MPa Pilot pressure range 0. to.0 MPa 0. to 0.7 MPa 76

24 Series Manifold: V- V- Applicable valve: 0/ Valve mounting side Pilot port Pilot port Manifold base Refer to page 76. Blanking plate Port Side Internal pilot type Port Side Common external pilot (Non-locking push) Common external pilot port x M5 x port (R): /4 Exhaust from both sides when there are 5 or more stations x M5 Pilot port x ø6.5 Mounting hole 6 (Air operated) 0 (External and internal pilot) 0.5 (M) 75 (M) 84 (L) x port : /4 Supply from both sides when there are 5 or more stations (Non-locking push) n x port : /4 L Dimension L L L n Formula L = n + 9, L = n + 4 n: Station

25 Power Valve: Position Valve Series Manifold: V4- V4- Applicable valve: 40/4 V4- Applicable valve: 40/4 Valve mounting side Pilot port Pilot port Manifold base Refer to page 76. Blanking plate Port side Port side Internal pilot Common external pilot (Non-locking push) x M5 Pilot port (For 40 only) x ø8.5 Mounting hole Common external pilot port x M5 x port (R): /, /8 Exhaust from both sides when there are 4 or more stations 79 (Air operated) 8 (External and internal pilot) 7.5 (L) 88 (M) 96 (L) x port : /, /8 Supply from both sides when there are 4 or more stations n x port : /4, /8 L Dimension L n L L 07 L = 46n +, L = 46n + 5 n: Station

26 Series Construction/Working Principle/Component Parts () R (R) () Closed center () R (R) This is a port switch valve in which the shaft 7 - extending from the driving piston ee opens/closes a pair of poppet valves 6. The poppet valve has a pressure balancing mechanism in which port pressure is constantly applied from the back and the center spring 4 is acting as a backup. When neither the pilot solenoid valve a nor b are energized (or when air is exhausted both from the port and of the air operated type), no force will act on the working piston, and the spring closes the poppet valve, thus the valve assumes the closed center position (DRW ()). When the pilot solenoid valve a is energized (or when pressurized air enters through the port of the air operated type), pilot air that enters the space above the working piston pushes down the piston and opens the lower poppet valve, thus connecting the port and port (DRW ()). The upper poppet valve continues to close the port (R) by means of pressure balance and the spring. When the pilot solenoid valve b is energized (or when pressurized air enters through the port of the air operated type), the pilot air that enters the space under the working piston pushes the piston upward and opens the upper poppet valve, thus connecting the port and port (R) (DRW ()). The lower poppet valve continues to close the port by means of pressure balance and the spring. 0 (Air operated) Port Port Port (R) Port Port 0 (Air operated) Port Port Port Port (R) Port Component Parts No. Description Material Body Cover Working piston Aluminum alloy Aluminum alloy Aluminum alloy 4 Center spring Stainless steel 5 Valve guide Aluminum alloy 6 Poppet valve Aluminum alloy, Rubber 7 Shaft Stainless steel 8 POM 9 Sub-plate Aluminum alloy 766

27 Power Valve: Position Valve Series Construction/Working Principle/Component Parts 0 (Air operated) 40 (Air operated) Port (R) Port, Port Port 50/70/90 (Solenoid) Port Port Port (R) Pilot valve a Pilot valve b Port P, P Port (R) Port Port 767

28 Connectors for the Series Body Sizes,, and 4 (For connectors for body sizes 50, 70, and 90, refer to VT07 series.) Plug Connector Lead Wire Length How to Use DIN Connector The standard length of a plug connector with lead wire is 00 mm, but the following lengths are also available. How to Order Connector Assembly DXT70 Connector Assembly with Cover 80 A Lead wire colors Lead wire Symbol Note with socket Nil Socket only ( pcs.) Blue ( pcs.) Red ( pcs.) Gray ( pcs.) Without lead wire For 00 VAC For 00 VAC For other VAC 4 Red: +, Black:- For DC Connector assembly with protective cover enhances dust protection. Effective to prevent short circuit accidents due to penetration of foreign matter into the connector part. Cover material adopts the chloroprene rubber which is excellent in weather ability and electric insulation properties. However, use caution not to splash cutting oil, etc. onto it. Simple and unencumbered appearance by adopting a round-shaped cord. How to Order DXT70 Series Specific Product Precautions Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions. A Connector assembly with cover: Dimensions Lead wire length Lead wire length Symbol (L mm) Nil How to Order Specify the connector assembly part number together with the part number for the plug connector's solenoid valve without connector. Note) The solenoid valve and the connector assembly are shipped separately. Lead wire length Lead wire length Symbol (L mm) Nil Wiring ) Loosen the set screws and pull out connector from the terminal block of solenoid valve. ) Pull out screws and insert a screwdriver to the slit area near the bottom of terminal block to separate the terminal block and housing. ) Loosen the terminal screws (slotted screws) on the terminal block, insert the core of the lead wire into the terminal in accordance with the wiring method, and secure with the terminal screws. 4) Tighten the ground nut to secure the cord. Change of electrical entry After separating the terminal block and housing, the cord entry direction can be changed by attaching the housing in the desired direction (4 directions in 90 increments). When equipped with light, avoid damaging the light with lead wire. Plug a connector in or out vertically, never at an angle. Applicable cables Cord O.D.: ø.5 to ø7 (Reference) 0.5 mm -core and -core wires equivalent to JIS C 06. Ground nut Tightening torque.65 to.5 N. m Washer Grommet (Rubber) (Voltage symbol) Refer to the table below Terminal screw ( places) Tightening torque 0. to 0.5 N. m DIN connector part no. Connector with light circuit Housing Without light DXT With Light Rated voltage Voltage symbol Part no. 00 VAC 00 VAC 0 VAC 00 V 00 V 0 V DXT DXT DXT VAC 0 V DXT VAC 6 VDC VDC 4 VDC 48 VDC 40 V 6 VD VD 4 VD 48 VD DXT DXT DXT DXT DXT AC circuit Set screw Tightening torque 0. to 0.4 N. m (Place to mount a light) Terminal block Slit area DC circuit Red Black Black Polarity indication NL: Neon light R: Resistor D: Protective diode LED: LED diode R: Resistor 768

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series 1 Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04 Three functions (pressure regulator, switching valve, and speed controller) are provided by a single valve. The conventional valve combination circuit has been condensed into a single valve. A large capacity

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000) 5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

3 Port 3 Position Valve

3 Port 3 Position Valve Port Position Valve Pilot Solenoid ir Operated ohs Intermediate stopping of cylinders * up to ø15 is possible. Pilot solenoid Manifold ir operated * For VEX 4, 00 mm/s, horizontal movement Power consumption:

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series

More information

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3

More information

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable

More information

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series VZS Series Variations Plug-in Type Base Mounted Type (With sub-plate) Non Plug-in Type Base Mounted Type (With sub-plate) Series Sonic conductance

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model 2 position 3 position

More information

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example E-P HYREG VY Series This hybrid regulator combines a regulator and a solenoid valve. Stepless control through electric signals Port sizes M5 to inches can be covered by combining an ultra-compact electro-pneumatic

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot 3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in

More information

High Pressure Coolant Valve

High Pressure Coolant Valve High Pressure Coolant Valve Series.5 MPa, 7.0 MPa Corresponding to high speed grinding and long drilling processes Coolant valve for high pressure coolant liquid (up to.5 MPa or 7.0 MPa) that is ideal

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR2 JIS Symbol type

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control Port Electro-Pneumatic Proportional Valve Series 000/000 Capable of actuating a cylinder and performing analog control of pressurization alone can be used to switch and actuate a cylinder and to perform

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm 4 Port Direct Operated Poppet Solenoid Valve Series D1000 High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure

More information

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Body Ported Base Mounted Series S000 S000 S000 S000 S000 S4000 S5000 Sonic conductance C [dm /s bar)] 4/ 5/(A/B R/R) Single Double.8.4

More information

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum 3 Port Direct Operated Poppet Rubber Seal Series 307 Large Flow Capacity, yet Compact Size. Dimensions (W X H X D) 30 X 54.5 X 33 307 Nl/min 206.02 or more, 1/4 Low Power Consumption /VO307 4.8W DC/Standard

More information

Rubber Seal VP300/500/700

Rubber Seal VP300/500/700 Port Pilot Operated Poppet Rubber Seal 00/500/700 High flow capacity Cv1.0 (00), Cv. (500), Cv.0 (700) Low power consumption: 1.8W(DC) Possible to use as either selector valve or divider valve Changeable

More information

1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption

1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption Port Solenoid Valve Direct Operated Poppet Type Power consumption Vacuum applications New [Option] RoHS 4 Standard wtype (Existing product: 4.8 W) 0. kpa Energy-saving type.8 w (Existing product: W) A

More information

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control Port Electro-Pneumatic Proportional Valve Series VER000/000 Capable of actuating a cylinder and performing analog control of pressurization VER alone can be used to switch and actuate a cylinder and to

More information

A variety of circuits in simple construction Intermediate and emergency stops with a large size cylinder

A variety of circuits in simple construction Intermediate and emergency stops with a large size cylinder Power Valve 3 Position Valve Series VEX3 A variety of circuits in simple construction Intermediate and emergency stops with a large size cylinder System construction with VEX Conventional system construction

More information

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S. High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure of 0.5MPa, subject to clean, dry air) 4 Port Direct

More information

Flow characteristics Max. (1) b Standard Specifications. P Manual override.

Flow characteristics Max. (1) b Standard Specifications. P Manual override. Port Direct Operated Solenoid Valve Series 0 Metal Seal Model Number of positions (Single) (Double) ( position) JIS Symbol Model Port size Rc (Nominal size) 0-0 8 ( A) 0- ( 8A) 0-0 8 (0A) 0-0 8 ( A) 0-

More information

Indicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A

Indicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A 1 3 Port Air Operated Valve Series VTA301 JIS Symbol VTA 301 Indicate VO for manifold. Port size Specifications How to Order Without connection port (For manifold) 01 1/8 02 1/4 Option Fluid Air Operating

More information

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control Process Series Port For Compressed Air and Air-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Cylinder actuation by external air he balance poppet

More information

Compact Proportional Solenoid Valve

Compact Proportional Solenoid Valve Compact Proportional Solenoid Valve Series Repeatability: % or less Hysteresis:1% or less Fluid Flow rate control range Note) Series Air, Inert gas to L/min to L/min Note) Varies depending on the model.

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

Series AV2000/3000/4000/5000

Series AV2000/3000/4000/5000 Soft Start-up Valve Series AV/3/4/5 Series introduced! A start-up valve that gradually increases supply pressure during start up and rapidly exhausts system air when the supply air is shut off AC AV AU

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

KV series. Innovatively detachable Manifold Block. Smart Solenoid Valve (plug-in type, D-SUB multi-connector type)

KV series. Innovatively detachable Manifold Block. Smart Solenoid Valve (plug-in type, D-SUB multi-connector type) CAT.1101E-S www.sym1.com KV series Innovatively detachable Manifold Block (DIN Rail Mounting) Smart Solenoid Valve (Plug-in type, D-SUB multi-connector ) Compact size with large flow capacity Exceedingly

More information

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A) ort Solenoid Valve ubber Seal Series SY00 Low power consumption: 0.W (Standard, Without light) (Current draw: m at V DC) Large flow capacity style:0.7w (Current draw: m at V DC) Body width: 0mm 7.8 Nl/min

More information

3 Port Solenoid Valve

3 Port Solenoid Valve 3 ort Solenoid Valve Series VKF300 ubber Seal Direct Operated oppet Type Compact yet provides a large flow capacity Body width 8 mm vailable in vacuum applications ( 0. ka) Can be used in vacuum/release

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Rubber Seal Port Solenoid Valve Series Manifold Single Unit ase Mounted Manifold VV01 V100 ar base P.18 ody Ported P.10 ase Mounted P.10 VQD VKF VK VT VS Separable base ody Ported Manifold P.1 Stacking

More information

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Soft Start-up Valve. AV2000/3000/4000/5000 Series Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off

More information

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1 Port Solenoid Valve Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Non plug-in manifold 0 0 S 60 Stations stations 0 stations SUP/EXH

More information

Vacuum Release Valve with Restrictor

Vacuum Release Valve with Restrictor INFORMATION Series SY3/5 Plug-in Only for External Pilot Vacuum Release Valve with Vacuum suction and release can be controlled with a single valve! PE Pilot EH port Flow rate adjustment of release air

More information

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Vacuum Release Valve with Restrictor Series SJ3A6 SJ Plug-in Type Connector Connection P.86 D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Non Plug-in Type Individual

More information

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control Process Valve Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external pilot

More information

3 Port Air Operated Valve VTA. Indicate VO for manifold. Port size. Nil 02 1/4. Specifications Fluid. Option Description Bracket (With screw)

3 Port Air Operated Valve VTA. Indicate VO for manifold. Port size. Nil 02 1/4. Specifications Fluid. Option Description Bracket (With screw) Series VTA301 How to Order VTA 301 Indicate VO for manifold. Port size Without connection port (For manifold) 01 1/8 02 1/4 F N T Option B Rc G NPT NPTF Without bracket Foot bracket JIS Symbol Specifications

More information

Series ZM Applications

Series ZM Applications Ejector Series ZM All in One! Built-in suction filter and silencer Air supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)

More information

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M. V3 Cover

More information

Exclusively for air pressure system and air-hydro circuit control

Exclusively for air pressure system and air-hydro circuit control Process Valve Series Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer Base Mounted Metal Seal/Rubber Seal VQ Built-in silencer, direct exhaust Space-saving profile All pilot valves are compactly mounted on one side. The space-saving design of mounting all fittings on one

More information

NAMUR Interface 5 Port Solenoid Valve

NAMUR Interface 5 Port Solenoid Valve NAMUR Interface 5 Port Solenoid Valve Series VFN000N 5 5 Specifications Valve Electrical entry Fluid Max. operating pressure Min. operating pressure Ambient and fluid temperature Lubrication Pilot operator

More information

3 Port Air Operated Valve

3 Port Air Operated Valve Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation

More information

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC Base Mounted Series VQZ00/00/00 VQZ00/00 / How to Order Valve Made to Order (For details, refer to page 9 and 4.) VQZ 5 5 M Series VQZ00 body width 5 mm VQZ00 body width 8 mm Type of actuation 4 N.C. N.O.

More information

Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero.

Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero. For General Purpose /3 Port Valve Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero. Wide variations Series For controlling pneumatic

More information

Vacuum Ejector. Series ZM

Vacuum Ejector. Series ZM Ejector Series All in One! Built-in suction filter and silencer Air supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)

More information

Electro-pneumatic Proportional Valve. Specifications. Model Flow type Pressure type VEF2121

Electro-pneumatic Proportional Valve. Specifications. Model Flow type Pressure type VEF2121 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 6-580 www.cmafh.com VEF Port Port Applicable power Body size Body size Electro-pneumatic Proportional

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Series 000 Compact and lightweight: 3 mm width Compact yet provides

More information

Manifold Specifications

Manifold Specifications Series 00 Manifold Specifications Manifold Specifications Model Manifold type P(SUP)/R(EXH) Valve stations A port porting specifications Port size For internal pilot For external pilot Location Direction

More information

Series SYJ300/500/700

Series SYJ300/500/700 ort Solenoid Valve ubber Seal Series SYJ00/00/00 Low power consumption: 0.W (Without light) (Current draw: 1m at 4V DC) Completely interchangeable ilot exhaust with the previous series VJ00/00/00 and VZ00/00.

More information

Manifold Specifications Stacking Type

Manifold Specifications Stacking Type Specifications Stacking Type Keeps environmental air clean from pilot exhaust Use of the VV5FS- manifold can exhaust intensively the pilot exhaust gas to the base side, and can prevent environmental aggravation

More information

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold Port Solenoid Valve VV00 Series Highly Integrated Unit Manifold po ted - pera irect-o d station es on rt valv ally ividu Ind wired n be ve ca val d. adde ector Con-inn connection) lug (For p ø connection

More information

5 Port Air Operated Valve

5 Port Air Operated Valve Port ir Operated Valve Series VF000/000/000 RoHS 22- Series VF000/000/000 Model Selection by Operating Conditions q ir Operated Valve: Single Unit Series Sonic conductance C[dm /(s bar)] Type of actuation

More information

Coolant Valve. Air Operated/External Pilot Solenoid

Coolant Valve. Air Operated/External Pilot Solenoid Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) lange type (3 to ) Low water hammer or details, refer to page

More information

AV2000-A/3000-A/4000-A/5000-A

AV2000-A/3000-A/4000-A/5000-A Soft Start-up Valve Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply Power consumption: 0.35 W * At 12/24 VDC

More information

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) type (3 to ) Low water hammer or details, refer to page 07. Large

More information

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is. Port Solenoid Valve Series VQ 00 Unprecedented high speed, stable response, and extra-long service life. ON:.ms, OFF: ms, Dispension accuracy ±ms (With indicator light and surge voltage suppressor; supply

More information

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type. Series -S00 ompact Direct Operated Port Solenoid Valve ontrol Valves ase mounted ody ported lean Series lean Series V S R oil voltage 24 VD VD VD VD VD Power consumption Pressure specification Flow rate

More information

Vacuum / Release Unit

Vacuum / Release Unit Rubber Seal Vacuum / Release Unit Series VQD1000-V Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area Smooth detachment of a work piece without over-blow

More information

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Vacuum / Release Unit Series VQD1000-V Rubber Seal Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area [Option] Smooth detachment of a work piece without

More information

Series ZM Applications

Series ZM Applications Ejector [Option] ll in One! Built-in suction filter and silencer ir supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)

More information

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC)

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC) Port Solenoid Valve/Direct Poppet Rubber seal Series VK3000 Nl/min 147 Compact/Width 18 X Length 8 (mm) Low power consumption 4W DC (Standard) 2W DC (Energy saver) Standard copper free specification All

More information

2 Port Solenoid Valve For Dust Collector

2 Port Solenoid Valve For Dust Collector The VX* series will be revised shortly. 2 Port Solenoid Valve For Dust Collector Series 2 port solenoid valve for dust collector Series In this L-shaped 2 port valve, the bag filter is cleaned by high

More information

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal Port Solenoid Valve Cassette Type Manifold Rubber Seal 7.mm (SJ000) SJ000 SJ000 Can be mounted together. 0mm (SJ000) Connector connection New New cable type manifold is added! New Additional options are

More information

Series ZM Applications

Series ZM Applications Ejector [Option] ll in One! Built-in suction filter and silencer ir supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)

More information

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection Rubber Seal Port Solenoid Valve Series SJ000/000 Cassette Type Manifold 0 mm 7. mm (SJ000) 0 mm (SJ000) Non plug-in type Individual wiring manifold SJ000 SJ000 Can be mounted together. Connecter connection

More information

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),

More information

5 Port Pilot Solenoid Valve Metal Seal. Configuration Voltage Electrical entry Option. Standard. 100V AC50/60Hz 200V AC50/60Hz 24V DC.

5 Port Pilot Solenoid Valve Metal Seal. Configuration Voltage Electrical entry Option. Standard. 100V AC50/60Hz 200V AC50/60Hz 24V DC. 5 Port Pilot Solenoid Valve Metal Seal SeriesVFS Models and Variations Body ported Base mounted Series VFS000 VFS2000 VFS3000 VFS2000 VFS3000 VFS4000 VFS5000 Port Size Effective area (mm 2 ) (Nl/min) 8:

More information

ISO Standard Solenoid Valve/SIZEq Rubber Seal Series VP7 6

ISO Standard Solenoid Valve/SIZEq Rubber Seal Series VP7 6 ISO Standard Solenoid Valve/SIZq Rubber Seal Series VP7 6 VP7 6 FPG D VP7 6 FG D position position Single solenoid (FG-S) Double solenoids (FG-D) Reverse pressure (YZ-S) Reverse pressure (YZ-D) Closed

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion

More information

5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type. Closed Center DS3330/DS3300. How to Order - Body Ported Type

5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type. Closed Center DS3330/DS3300. How to Order - Body Ported Type 5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type COMPACT SIZE AND LIGHT WEIGHT LARGE FLOW CAPACITY LOW POWER CONSUMPTION DESIGNED FOR NON-LUBRICATED SERVICE DV000 Symbol Single DS330/ How

More information