Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example

Size: px
Start display at page:

Download "Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example"

Transcription

1 E-P HYREG VY Series This hybrid regulator combines a regulator and a solenoid valve. Stepless control through electric signals Port sizes M5 to inches can be covered by combining an ultra-compact electro-pneumatic pilot valve and a port high-capacity exhaust main regulator. Simple circuit configuration (A) (A) P (R) P (R) (P) (R) (P) n n (P) (P) (A) Simplified main circuit Simplified pilot circuit Application example Capable of performing multistage pressure control and stepless pressure control by varying the electrical signals. Cylinder Thrust Control Tension control balancer Example Auto balancer (R) (P) (R) (P) (A) (A) (A) VYD Piping labor reduced A flexible system has been adopted. (P) E-P HYREG Drive and Thrust Control Cylinder behavior and pressurization control for peening Example and stamping Welding pressure control of spot welding gun cylinder Loading cylinder control (R) Pressure Control of Tank Flow Control of Various Fluids Automatic adjustments For remote control of another air operated valve (R) Ease of handling Manifold capable Air Flow Control of Nozzle Note) Air blowing Air cooling VY Having the amplifier built into the electro-pneumatic pilot valve, only an external power supply and signal (voltage, current) need to be connected. Using the VVEXB// series, a maximum station manifold is possible. (R) (P) (A) Nozzle ARJ AR5 to 95 ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY VBA VBAT AP (R) (P) (A) (P) (A) Tank Note) Use for the sonic flow. 99

2 E-P HYREG VY Series How to Order E-P HYREG Maximum operating pressure:.9 MPa Made to Order X9 Low wattage specification P. Pilot type Internal pilot External pilot Note ) Note ) Except body size D VY Power source/command signal Symbol Power source voltage DC Command signal DC Input impedance Nil to 5 V 67 kω to V kω V to ma Ω to ma 5 to 5 V 67 kω 6 to V kω V 7 to ma Ω to ma Thread type Nil Rc F G () N NPT T NPTF Note ) Not conforming to ISO Symbol Internal pilot (A) External pilot (A) (R) (P) P (R) (P) Body size Port size Rc Option Mounting Base mounted Body ported Symbol Symbol Port (P), (A) Port (R) B (Bracket) F (Foot) G (Pressure gauge) N (Silencer) D Without sub-plate M5 M5 B M5 Without sub-plate M5 Without sub-plate Without sub-plate A M5 M5 () () () () Applicable pilot valve () VYD- (5) VYB- (5) Note ) Only bracket or foot may be mounted. Note ) When replacing the pilot valve, it may not satisfy characteristics such as accuracy, etc. Confirm the product works under the operating conditions before using. If SMC is requested to repair the product, SMC confirms whether characteristics are satisfied. Note 5) in the applicable pilot valve part number is designated for the power source/command signal. Note 6) Cut off the command signal when the pressure control on the outlet side is not required, such as when the line is temporarily halted, etc. Refer to Specific Product Precautions on page 6.

3 E-P HYREG R VY Series Standard Specifications Model VYD Port M5 (P) Port size (A) M5 (R) Weight (kg) (). Hysteresis ().9 MPa Sensitivity ().5 MPa Repeatability () ±.5 MPa Response time () ms Fluid Ambient and fluid temperature Maximum operating pressure Regulating pressure range External pilot pressure (Direct operated) Command signal () Power supply Electrical entry Applicable cable Bleed air flow (Pilot EXH port) Installation Lubrication Option Description Bracket (With bolt, washer) Pressure gauge Pilot EXH port silencer B F G N VYD AN-M5 VYA VYB VY VY VY VEX-A VEXA--A VEX--A VEXA--A VEX--A G7--R-X7 G7-- AN-M5 Sub-plate and Base Gasket Part No. Valve size D B Sub-plate VEXD-5 VEXB-- (Port size: M5) Port size VYA VYB VY VY VY VY VY5 VY7 VY9 M5 M5 6 M5 M Symbol A B Port size M5. MPa.9 MPa ±.9 MPa P Symbol Nil F N T Part no. Thread type Thread type Rc G (7) NPT NPTF G6-- AN-.7 MPa. MPa ±.9 MPa VY VY5 VY7 VY9 VEX5-A VEX7-A VEX9-A AN-M5.5 MPa. MPa ±. MPa ms Air to 5 C (No condensation).9 MPa.5 to. MPa (Supply pressure.9 MPa) Set pressure +. to.9 MPa (VY ) to 5 VDC, to VDC, to ma DC, to ma DC VDC±%, VDC ±%,. W or less DIN terminal Cable O.D. ø to 6.5 When not operating: Zero, When operating: L/min (ANR) (Supply pressure.9 MPa) Universal Not required () Note ) The mass of the base mounting type (D/B// size) with sub-plate is indicated. Note ) All property values indicate maximum values. Note ) Cut off the command signal when the pressure control on the outlet side is not required, such as when the line is temporarily halted, etc. Refer to Specific Product Precautions on page 6. Note ) To lubricate the outlet side of VY, use VY as an external pilot. Avoid lubrication to the pilot air. Note 5) The non-lubricated specification is not applicable to these models. Note 6) The service life is approximately to 5 operating hours. (When using AF + AFM) This may be approximately hours with ultra-dry air (dew point C or equivalent). G6-- AN- ARJ AR5 to 95 ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY VBA VBAT AP Base gasket VYD-7 VEXB-- Valve size Sub-plate VEX-9- P VEX-A- P Port size Thread type Port size Thread type Symbol Port size Symbol Thread type Symbol Port size Symbol Thread type A B Nil F N T Rc G (7) NPT NPTF A B C Nil F N T Rc G (7) NPT NPTF Base gasket Note 7) Not conforming to ISO79-. VEX-- VEX- 99

4 VY Series Characteristics Command Signal Outlet Pressure Characteristics (Characteristics of pressure setting) Port (P) Pressure.9 MPa (-X9:.7 MPa) VYD Port (A) pressure (MPa) VYA/A,VYB/B Port (A) pressure (MPa) VY/,VY/ Port (A) pressure (MPa) VYD-5 5 V A VYB -5 5 V VYD V A VYB V VYD-7 6 ma A VYB -7 6 ma VYD- 5 5 ma A VYB ma VY -5 5 V VY V VY -7 6 ma VY ma Command signal Command signal Command signal VY/ Port (A) pressure (MPa) VY -5 5 V VY V VY -7 6 ma VY ma Command signal VY/ Port (A) pressure (MPa) VY -5 5 V VY V VY -7 6 ma VY ma Command signal VY5/5 Port (A) pressure (MPa) VY5-5 5 V VY V VY5-7 6 ma VY5-5 5 ma Command signal VY7/7 Port (A) pressure (MPa) VY7-5 5 V VY V VY7-7 6 ma VY7-5 5 ma Command signal VY9/9 Port (A) pressure (MPa) VY9-5 5 V VY V VY9-7 6 ma VY9-5 5 ma Command signal Command signal voltage (current) for starting the operation of a pilot valve VYD (-X9) (direct operated) (There is dispersion in the following range) Symbol () Input signal Operation start range Nil, 5, 6, 7, to 5 VDC to VDC to ma DC to ma DC.9 to.7 VDC. to. VDC.7 to. ma DC. to. ma DC Note ) Enter symbols above in VYD-. indicates power supply and a command signal. Note ) Other body sizes add the dispersion on the above data when the main valve activates. For the command signal range of the low wattage specification (X9), refer to the specifications on page. 99

5 E-P HYREG R VY Series Pressure Characteristics VYD VYA /B Port (A) pressure (MPa) Port (A) pressure (MPa) Port (A) pressure (MPa) Set point Port (P) pressure (MPa) VY / VY Set point Port (P) pressure (MPa) VY VY5 VY7 Set point Port (P) pressure (MPa) Port (A) pressure (MPa) Port (A) pressure (MPa) Port (A) pressure (MPa) VY9 Set point Port (P) pressure (MPa) Set point Port (P) pressure (MPa) Set point Port (P) pressure (MPa) ARJ AR5 to 95 ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY VBA VBAT AP Port (A) pressure (MPa) Set point Port (A) pressure (MPa) Set point Port (P) pressure (MPa) For the low wattage specification (X9), the maximum pressure of port (P) is.7 MPa. Port (P) pressure (MPa) 99

6 VY Series Characteristics Flow Rate Characteristics VYD Port (A) pressure (MPa) Port (P) pressure.9 MPa VYA /B Port (A) pressure (MPa) Port (P) pressure.9 MPa (L/min(ANR)) (L/min(ANR)) Exhaust Flow rate Reduced pressure supply Exhaust Flow rate Reduced pressure supply VY / Port (A) pressure (MPa) Port (P) pressure.9 MPa VY / Port (A) pressure (MPa) Port (P) pressure.9 MPa (L/min(ANR)) (L/min(ANR)) Exhaust Flow rate Reduced pressure supply Exhaust Flow rate Reduced pressure supply VY5 Port (A) pressure (MPa) Port (P) pressure.9 MPa VY7 Port (A) pressure (MPa) Port (P) pressure.9 MPa (L/min(ANR)) (L/min(ANR)) Exhaust Flow rate Reduced pressure supply Exhaust Flow rate Reduced pressure supply 99

7 E-P HYREG R VY Series VY9 Port (A) pressure (MPa) Port (P) pressure.9 MPa. Exhaust Time from L Tank (L/min(ANR)) Exhaust Flow rate Reduced pressure supply Exhaust Time. Exhaust Time from.5 MPa to. MPa Exhaust time (s) Exhaust time (s) Tank size (L) Exhaust Time from.5 MPa to. MPa / / Exhaust Time from L Tank Pressure (MPa) Pressure (MPa) Exhaust time (s) Exhaust time (s). Exhaust time from optional pressure point Ex.] Using VY5, lower the 5 L tank pressure from. to.. a) If describing the above graph in accordance with graphs, the exhaust time is read; 7 = s. Initial pressure Exhaust time Numerical target of pressure lowering / b) Then, to convert the time into one from a 5 L tank. Tank capacity Read exhaust time Then, the result is s. / ARJ AR5 to 95 ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY VBA VBAT AP Tank size (L) 995

8 VY Series Dimensions VYD x ø. Applicable cable O.D. ø to ø6.5 All types are the same in terms of connection. x M5 Port (P), (A), (R) Silencer (Option) VYA Applicable cable O.D. ø to ø6.5 All types are the same in terms of connection. M5 external pilot port (VYA only) x M5 Port (P), (A), (R) x ø.5 x M thread depth 6.5 (For bracket and foot mounting) x ø.5 Foot (Option) VEXA--A Hexagon socket head cap screw M L = ( pcs.) (With spring washer) ( ) Bracket (Option) VEXA--A Hexagon socket head cap screw M L = ( pcs.) ((With spring washer) ) 996

9 E-P HYREG R VY Series VYB M5 external pilot port (VYB only) ARJ AR5 to 95 /6 Gauge port x ø.5 Mounting hole All types are the same in terms of connection. ARX AMR Pressure gauge (Option) G7--R-X7 Applicable cable O.D. ø to ø6.5 ARM ARP IR -A IR IRV VY M5, / Port (P), (R) Applicable cable O.D. ø to ø6.5 M5, / Port (A) VEX SRH SRP SRF ITV M5 Pilot EXH port Pressure gauge (Option) G7-- All types are the same in terms of connection. M5 external pilot port (VY only) IC ITVH ITVX PVQ Silencer (Option) AN-M5 VY / gauge port VBA VBAT Foot (Option) VEX-- Hexagon socket head cap screw M L = ( pcs.) ((With spring washer) ) /, / Port (A) AP /, / Port (P), (R) Bracket (Option) VEX--A Hexagon socket head cap screw M L = ( pcs.) ((With spring washer) ) x ø.5 x M thread depth 6.5 (For bracket and foot mounting) x ø.5 997

10 VY Series Dimensions VY / Gauge port All types are the same in terms of connection. x ø.5 M5 external pilot port (VY only) Pressure gauge (Option) G7-- Applicable cable O.D. ø to ø6.5 P Port M5 Pilot EXH port x /, / Port (P), (A), (R) Silencer (Option) AN-M5 VY Applicable cable O.D. ø to ø6.5 All types are the same in terms of connection. / Gauge port / Pilot EXH port /, /, / Port (P) Silencer (Option) AN- /, /, / Port (R) Bracket (Option) VEX-A Hexagon socket head cap screw M5 L = ( pcs.) (With spring washer) ( ) elongated / external pilot port (VY only) /, /, / Port (P) x M5 thread depth (For bracket mounting) 99 View A Pressure gauge (Option) G6--

11 E-P HYREG R VY Series VY /, /, / Port (P), (R) ARJ AR5 to 95 ARX x ø5.5 Silencer (Option) AN-M5 M5 Pilot EXH port All types are the same in terms of connection. / external pilot port (VY only) Applicable cable O.D. ø to ø6.5 View A AMR ARM ARP IR -A IR IRV VEX SRH /, /, / Port (A) SRP SRF ITV VY5 IC ITVH ITVX Applicable cable O.D. ø to ø6.5 / Gauge port All types are the same in terms of connection. Pressure gauge (Option) G6-- / external pilot port (VY5 only) Silencer (Option) AN- / Pilot EXH port Bracket (Option) VEX5-A Hexagon socket head cap screw M6 L = ( pcs.) (With spring washer) ( ) x ø9 PVQ VY VBA VBAT AP x M6 thread depth 9 (For bracket mounting) /, /, Port (R) x /, /, Port (P), (A) View A 999

12 VY Series Dimensions VY7 All types are the same in terms of connection. Applicable cable O.D. ø to ø6.5 Pressure gauge (Option) G6-- Bracket (Option) VEX7-A Hexagon socket head cap screw M6 ( L = ( pcs.) (With spring washer) ) / Gauge port / external pilot port (VY7 only) Silencer (Option) AN- / Pilot EXH port x M6 thread depth 6 (For bracket mounting) x ø9 Mounting ( hole ), / Port (R) x, / Port (P), (A) View A VY9 All types are the same in terms of connection. Pressure gauge (Option) G6-- / Gauge port Applicable cable O.D. ø to ø6.5 Pg.7 / external pilot port (VY9 only) / Pilot EXH port Silencer (Option) AN- Port (R) x M6 thread depth (For bracket mounting) x ø7 Bracket (Option) VEX9-A Hexagon socket head cap screw M6 L = 5 ( pcs.) (With spring washer) ( ) x /, Port (P), (A) View A

13 E-P HYREG R VY Series Construction/Component Parts/Working Principle VYD Cover Body Pressure sensor Feedback passage Control circuit VYA, VYB (Pilot valve: VYD- ) (R) Solenoid valve (P) (A) Sub-plate Port P Power supply Command signal The VYD, which is the smallest direct drive, consists of a solenoid, pressure sensor, control circuit, body cover, and a sub-plate. The type with sub-plate can be used alone, and the type without sub-plate can also be used as a pilot valve. All types are the same in terms of connection. Working principle When the command signal is below VDC, (refer to page 99) the solenoid valve is inactive, and the port (A) pressure is zero. When a command signal between and 5 VDC is provided, the solenoid is activated. The port (A) pressure is fed back to the control circuit by the pressure sensor. The control circuit compares the feedback signal with the size of the command signal that was provided, and: ) If the feedback signal is smaller, current is supplied to the solenoid valve to raise the port (A) pressure [from (P) to (A)]. ) If the feedback signal is greater, current is not supplied to valve to reduce the port (A) pressure [from (A) to (R)]. The above processes ) and ) are repeated at high speeds to set the port (A) pressure. Circuit Power supply Input signal Solenoid valve (P) (R) Control circuit Working principle The supply [(P) to (A)] valve of valve y and the exhaust [(A) to (R)] valve close due to the balance between actuating forces F and F. Actuating force F is applied to the right surface of pressure regulation piston e by the pilot pressure (pilot valve assembly w: VYD- ), and actuating force F is applied to the left surface of the pressure regulation piston by the port and pressure that passes through the feedback passage. Thus, the port (A) pressure that coprresponds to the pilot pressure is established. When the port (A) pressure becomes higher than the pilot pressure, F becomes greater than F. This causes only the pressure regulation piston to move to the right, and the exhaust valve seat to open, allowing the air to be discharged from port (A) to port (R). When the port (A) pressure drops to reach a balance, the regulator returns to the set state. Conversely, if the port (A) pressure is lower than the pilot pressure, F becomes lower than F. This causes the pressure regulating piston to move the valve to the left, and the supply valve seat to open, allowing the air to be supplied from port (P) to port (A). When the port (A) pressure balances, the regulator reuturns to the set state. P Pressure sensor (A) ARJ AR5 to 95 ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY VBA VBAT AP Feedback passage Sub-plate Component Parts Description Material Body Zinc alloy die-casted Pilot valve assembly Adjusting piston Aluminum alloy Spring Stainless steel Valve guide Stainless steel Valve Aluminum alloy/rubber Retainer Aluminum alloy Rod Stainless steel/rubber

14 VY Series Construction/Component Parts/Working Principle VY, VY, VY, VY (Pilot valve: VYD- ) VY5, VY7, VY9 (Pilot valve: VYB- ) P port Port (R) Feedback passage Working principle The pair of poppet valves u close due to the balance between actuating forces F and F. A c t u a t i n g f o r c e F i s a p p l i e d t o t h e t o p surface of pressure regulation piston r by the pilot pressure (pilot valve assembly q: VY D B - ), and actuating force F is applied to the bottom surface of the piston by the port (A) pressure that pases through the feedback passage. Thus, the port (A) pressure that corresponds to the pilot pressure is established. The poppet valve, which maintains a pressure balance with the port (A) pressure, is backed up by spring t (refer to the diagram on the left). When the port (A) pressure becomes higher than the pilot pressure, F becomes higher than F. This causes the pressure regulation piston to move upward, and the top poppet valve to open, allowing the air to be discharged from port (A) to port (R). When the port (A) pressure drops to reach a balance, the regulator returns to the state shown in the diagram to the left. Conversely, if the port (A) pressure is lower than the pilot pressure, F becomes less than F. This causes the pressure regulation piston to move downward, and the lower poppet valve to open, allowing the air to be supplied from port (P) to port (A). When the port (A) pressure rises to reach a balance, the regulator returns to the state shown in the diagram to the left. Port (A) Port (P) Component Parts No. Description Material Pilot valve assembly Body Cover Adjusting piston Spring Valve guide Poppet valve Shaft Valve guide Aluminum alloy Aluminum alloy Aluminum alloy Stainless steel Aluminum alloy Aluminum alloy/rubber Stainless steel Aluminum alloy

15 VY Series Made to Order Specifications Please contact SMC for detailed dimensions, specifications and lead times. Symbol Low Wattage Specification:. W or less -X9 Under operating conditions that the ON time, such as charging to the tank is long, the service life may be shortened due to the heat generation of the product. When the operating pressure is.7 MPa or less, it is recommended to use the special product -X9 (Service life: Approx. 7 operating hours) that is a type of low wattage and suppresses heat generation. Please note that the product characteristics are those with.7 MPa or less of the standard specifications. How to Order E-P HYREG Maximum operating pressure:.7 MPa VY X9 Power source/command signal Symbol Power source voltage DC Command signal DC Input impedance Nil to V 67 kω to 7.5 V kω V to 6 ma Ω to 5 ma 5 to V 67 kω 6 to 7.5 V kω V 7 to 6 ma Ω to 5 ma Thread type Nil Rc F G () N NPT T NPTF Note ) Not conforming to ISO79-. Body size Port size Rc Option Mounting Symbol Symbol Port (P), (A) Port (R) B (Bracket) F (Foot) G (Pressure gauge) N (Silencer) Applicable pilot valve () D Without sub-plate M5 M5 Without sub-plate B M5 M5 Base Without sub-plate mounted Without sub-plate VYD- -X9 (5) Body ported A M5 M5 () () () () 5 6 Pilot type Internal pilot External pilot Note) Note ) Except body size D Low Wattage Specification VYB- 7 -X9 (5) 9 Note ) Only bracket or foot may be mounted. Note ) When replacing the pilot valve, it may not satisfy characteristics such as accuracy, etc. Confirm the product works under the operating conditions before using. If SMC is requested to repair the product, SMC confirms whether characteristics are satisfied. Note 5) l in the applicable pilot valve part number is designated for the power source/command signal. ARJ AR5 to 95 ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY VBA VBAT AP Specifications (Specifications other than those below are the same as the standard type.) Max. operating pressure (6).7 MPa Regulating pressure range.5 to.66 MPa (Supply pressure.7 MPa) External pilot pressure Set pressure +. MPa to.7 MPa Command signal (7) to VDC, to 7.5 VDC, to 6 ma DC, to 5 ma DC Power supply VDC ±%, VDC ±%,. W or less Bleed air flow (Pilot EXH port) When not operating: Zero, When operating: 7 L/min (ANR) (Supply pressure.7 MPa) Note 6) The supply pressure must be under the maximum operating pressure. If the supply pressure exceeds the maximum operating pressure, this may cause abnormal leakage from the pilot valve or abnormal set pressure to occur. Note 7) Cut off the command signal when the pressure control on the outlet side is not required, such as when the line is temporarily halted, etc. Refer to Specific Product Precautions on page 6.

16 P P P P E-P HYREG Manifold Specifications Using the VVEXB// series, a maximum of stations manifold is possible. Specifications Applicable valve VYB VY VY Valve stations () to stations to stations to 6 stations Passage Common supply/exhaust Pilot type Internal pilot, Common external pilot () Pilot port size M5 Port size port (P), (A), (R),, Blanking plate assembly () VEXB-6 VEX-7 VEX-5 Note ) VYB 6 stations or more, VY 5 stations or more, VY stations or more supply pressure to the ports (P) on both sides of the manifold and exhaust pressure from the port (R) on the both sides. Note ) When used as a common external pilot, select the internal pilot specification as an applicable valve. Note ) Gasket and mounting bolts are equipped. How to Order Dimensions VVEXB 9.5 VVEX B 5 Body size Pilot type Valve stations Port size B Note ) Internal pilot stations (P), (R) (A) For VYB Common external pilot Note ) stations Internal pilot stations For VY Common external pilot stations For VY A Internal pilot stations B Common external pilot 6 6 stations C VY manifold pilot type Body size B, Pilot type Manifold base part no. Applicable valve part no. Internal pilot manifold VVEX -- - Common external pilot manifold VVEX -- - VY Individual external pilot manifold VVEX VY Note) It is recommended to use a common type when the external pilot type is used. Body size Pilot type Manifold base part no. Applicable valve part no. Internal pilot manifold VVEX-- - VY Common external pilot manifold VVEX-- - VY Individual external pilot port: P M5 (VYB- only) x ø5.5 (For mounting).5 P= L L All types are the same in terms of connection..5 Port (R): x / Exhaust from the both sides for 6 stations or more. Common external pilot port: See Note for P. x M5 (VVEXB-n- only) Enter the valves and the blank plates to be placed on a manifold in order, starting at the left side of the manifold base (with port (A) facing you). Ex.) VVEX--5- VY--G pcs. VEX-7 pc. Piping thread type Nil Rc F G Note ) N NPT T NPTF Note ) In the case of VVEXB, the in the first digit of the valve station number is a dummy part number. Note ) Not conforming to ISO Port (A): n x / Blanking plate Stations Dimension L L A P= A 9 9 R P P Port (P): x / Pressurize from the both sides for 6 stations or more. Note for P Confirm internal pilot or common external pilot by checking whether P has a M5 screw or not. Internal pilot P has no M5 screw. Common external pilot P has an M5 screw.

17 Manifold Specifications VY Series Dimensions VVEX All types are the same in terms of connection. Individual external pilot port: P M5 (VY- only) Stations Dimension L L VVEX Port (A): n x / Blanking plate x ø All types are the same in terms of connection. Pilot EXH port: P Port (P): x / Pressurize from the both sides for 5 stations or more. x ø.5 Port (P): x /, / Pressurize from the both sides for stations or more. Common external pilot port: See Note for P. x M5 (VVEX--n- only) Pilot EXH port: P Common external pilot port: See Note for P. x M5 (VVEX--n- only) Blanking plate Port (R): x / Exhaust from the both sides for 5 stations or more. Note for P Confirm internal pilot or common external pilot by checking whether P has a M5 screw or not. Internal pilot P has no M5 screw. Common external pilot P has an M5 screw. ARJ AR5 to 95 ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY VBA VBAT AP Port (A): n x /, / Port (R): x /, / Exhaust from the both sides for stations or more. Dimension Stations L L Note for P Confirm internal pilot or common external pilot by checking whether P has a M5 screw or not. Internal pilot P has no M5 screw. Common external pilot P has an M5 screw. 5

18 VY Series Specific Product Precautions Be sure to read this before handling the products. Refer to back page 5 for Safety Instructions and each Best Pneumatics for Precautions on every series. Piping Caution Tightening the fittings and their torque When screwing fittings into the valves, make sure to tighten them to the proper torque values given below. Connection thread: M5 First, tighten by hand, then use a wrench appropriate for the hexagon flats of the body to tighten an additional /6 to / turn. A reference value for the tightening torque is to.5 N m. For the fitting with sealant R or NPT, first, tighten it by hand, then use a wrench appropriate for the hexagon flats of the body to tighten it a further two or three turns. For a tightening torque guide, refer to the table below. Connection thread size (R, NPT) Operating Fluid Caution Caution Wires to be Used Caution Proper tightening torque (N m) to 5 to 5 to to 5 to 6 to to to 5 to 5. If drainage or debris is present in the supply pressure line, the sliding resistance of the main valve or piston, etc. increases, resulting in a malfunction. Therefore, in addition to the air filter (SMC s AF series), make sure to use a mist separator (SMC s AM, AFM series). Concerning the quality of the operating air, refer to SMC s air preparation equipment selection guide (pages and ).. Make sure to perform a maintenance periodically on air filter and mist separator (by discharging the drain and cleaning a filter element or replacing with new one). Pressure Gauge For products with pressure gauge, use caution about the durability of a pressure gauge, since it may be affected by the sudden pressure changes during operation. Use core shielded wires measuring.5 (mm ) for the power supply and signal lines according to the respective number of conductors. When connecting the shielded braided wire, connect it to the ground of the signal generator. As a rule, the electro-pneumatic hybrid regulator should be installed in a location that is free of noise or is shielded. If it must be installed in an environment with poor noise conditions, eliminate the power supply noise by using a line filter, Z-wrap, or a spark killler on the V power supply or signal source line. The length of the power suply and signal lines must be kept as short as possible. Power supply Signal generator (Input signal) To field ground (F. G.) Shielded wire To ground (GND) Terminal no. Details of wire connection Power supply Command signal GND (COMMON) How to Use DIN Terminal Caution Wiring procedures. Loosen the retaining screw and pull the connector from the solenoid valve terminal block.. Remove the retaining screw, insert a flat head screwdriver into the groove below the terminal block and pry it up to separate the terminal block from the housing.. Loosen the terminal screws (slot head screws) on the terminal block. Then, in accordance with the wiring procedure, insert the cord of the lead wires into the terminals and tighten the terminal screws to secure in place.. Tighten the ground nut to secure the cord. Outlet changing procedure After the terminal block has been separated from its housing, reassemble the housing in the desired direction (in four 9 increments) to change the direction of the cord outlet. Precautions Kindly insert the connector straight in without tilting it, and pull it out straight. Applicable wire Ground nut Cord external diameter: ø to ø6.5 c.f..5 mm core wire (JIS C 6 equivalent) Connector part no.: VK-- Input Signal Caution Retaining screw Housing (Rated symbol) Terminal screw ( locations) Washer Grommet (Rubber) (Light mounting position) Terminal block Slit area Input signal when out of operation There is dispersion in operation start voltage (current) for the input signal. (Refer to page 99.) If the command signal when out of operation exceeds the lower limit of the operation start voltage (current), the solenoid valve inside the pilot valve starts to activate and may be in the operation state. The service life of this product varies depending on the operating time of the solenoid valve inside the pilot valve. Be sure to cut off the command signal when the pressure control on the outlet side is not required, such as when the line is temporarily halted, etc. (Refer to Service Life below.) Service Life Caution The pilot valve service life is approximately to 5 operating hours. (When using AF + AFM) This may be approximately hours with ultra-dry air (dew point C or equivalent). For the low wattage specification (X9), the service life is approximately 7 operating hours. (When using AF and AFM) Bleed Caution Since the pilot solenoid valve enters the normally operating status and the air is discharged continuously from the pilot EXH port (port (R) for VYD, VYA and VYB ) in the pressure setting status, the bleed sound is produced. However, this is not an abnormal phenomenon. Related Products: Silencer (AN series) Noise reducing effect: db or more. Large effective area Refer to Best Pneumatics No. 7 for details. Exhaust cleaner (AMC series) Provides noise reduction and oil mist collecting functions. Can also be used in a common piping system. Oil mist recovering efficiency 99.9% Noise reduction efficiency 5 db or more Refer to Best Pneumatics No. 7 for details. 6

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control Port Electro-Pneumatic Proportional Valve Series VER000/000 Capable of actuating a cylinder and performing analog control of pressurization VER alone can be used to switch and actuate a cylinder and to

More information

Power Valve Precision Regulator

Power Valve Precision Regulator Power Valve Precision Regulator VEX Series High precision, large capacity relief regulator port large exhaust capacity pressure reducing valve which utilizes a nozzle flapper mechanism available as air

More information

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control Port Electro-Pneumatic Proportional Valve Series 000/000 Capable of actuating a cylinder and performing analog control of pressurization alone can be used to switch and actuate a cylinder and to perform

More information

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S. Electro-pneumatic proportional valve: Flow type (VEF) Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical throttle valve function.) A model that is suitable

More information

Electro-Pneumatic Regulator/Electronic Vacuum Regulator

Electro-Pneumatic Regulator/Electronic Vacuum Regulator Electro-Pneumatic Regulator/Electronic Vacuum Regulator Series Stepless control of air pressure proportional to an electrical signal // series are compatible with various input specifications, including

More information

Electro-pneumatic Proportional Valve. Specifications. Model Flow type Pressure type VEF2121

Electro-pneumatic Proportional Valve. Specifications. Model Flow type Pressure type VEF2121 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 6-580 www.cmafh.com VEF Port Port Applicable power Body size Body size Electro-pneumatic Proportional

More information

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)*

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)* 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator ITVH Series ARJ RoHS Maximum supply pressure Set pressure range Stability 3.0 MPa 0.2 to 2.0 MPa ARX AMR Stepless control of air

More information

4 Note 1) Value for communications type. (PROFIBUS DP)

4 Note 1) Value for communications type. (PROFIBUS DP) Electro-Pneumatic Regulator/Electronic Vacuum Regulator Series Stepless control of air pressure proportional to an electrical signal Series // are compatible with various input specifications, including

More information

Electro-Pneumatic Regulator / Electronic Vacuum Regulator

Electro-Pneumatic Regulator / Electronic Vacuum Regulator Electro-Pneumatic Regulator / Electronic Vacuum Regulator Series Series Model Regulating pressure range Port size Page Series With a simplified high-density circuit board design, an extremely compact size

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

Pressure Control Equipment

Pressure Control Equipment Control High-pressure Precision General Purpose Special Fluid/Deionized Water (Pure Water) Detection Control Control (General purpose, high-pressure, precision, vacuum, special fluid, deionized water (pure

More information

Manifold Regulator Modular Type. Regulator for manifold. Body size. Number of stations stations. 10 stations. Standard Specifications

Manifold Regulator Modular Type. Regulator for manifold. Body size. Number of stations stations. 10 stations. Standard Specifications Manifold Regulator Modular Type /3000 Series modular type that can be freely mounted on a manifold station. Optimal for central pressure control. Easily set up using the new knob. lso has a One-touch lock

More information

Standard Specifications. Model IN side OUT side Fluid Proof pressure Maximum operating pressure

Standard Specifications. Model IN side OUT side Fluid Proof pressure Maximum operating pressure Miniature Regulator Series ARJ1020F 2 Construction/Dimensions Lock nut M8 X 0.75 Panel screw Panel mounting hole Precautions Be sure to read before handling. Refer to pages 14-21-3 to 14-21-4 for Safety

More information

Standard Specifications

Standard Specifications Miniature Regulator ARJ020F Compact and lightweight (6g) Low cracking pressure 0.02MPa Standard model equipped with backflow function Standard Specifications Port size IN side OUT side (Applicable tube

More information

Miniature Regulator Series ARJ310

Miniature Regulator Series ARJ310 Miniature Regulator Series 30 Compact and lightweight (Main body 65 g) 8.3 Improved flow characteristics 0. 0. 0 00 00 300 400 500 Allows smaller mounting pitch 8.8mm 0-M5 30-0 Inlet pressure: MPa Accommodates

More information

Manifold Regulator Modular Type. Regulator for manifold. Body size. Number of stations stations. 10 stations. Standard Specifications

Manifold Regulator Modular Type. Regulator for manifold. Body size. Number of stations stations. 10 stations. Standard Specifications Manifold Regulator Modular Type Series /3000 modular type that can be freely mounted on a manifold station. Optimal for central pressure control. Easily set up using the new handle. lso has a Onetouch

More information

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04 Three functions (pressure regulator, switching valve, and speed controller) are provided by a single valve. The conventional valve combination circuit has been condensed into a single valve. A large capacity

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series 1 Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

Standard Specifications

Standard Specifications Miniature Regulator ARJ020F Compact and lightweight (6g) Low cracking pressure 0.02MPa Standard model equipped with backflow function Standard Specifications Port size IN side OUT side (Applicable tube

More information

Compact Proportional Solenoid Valve

Compact Proportional Solenoid Valve Compact Proportional Solenoid Valve Series Repeatability: % or less Hysteresis:1% or less Fluid Flow rate control range Note) Series Air, Inert gas to L/min to L/min Note) Varies depending on the model.

More information

Electro-Pneumatic Regulator. Standard Specifications. Minimum supply pressure Maximum supply pressure Regulating pressure range

Electro-Pneumatic Regulator. Standard Specifications. Minimum supply pressure Maximum supply pressure Regulating pressure range 000 Electro-Pneumatic Regulator Series 000/000 Standard Specifications Symbol Straight type Right angle type Model Minimum supply pressure Maximum supply pressure Regulating pressure range Voltage Power

More information

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL SMC REULATOR ITV2 Electro-pneumatic Regulator Electronic Vacuum Regulator Series ITV Series ITV Series Model Regulating pressure range Port size With a simplified high-density circuit board design, an

More information

Series VCHR. Direct Operated Regulator for 6.0 MPa (Relieving Type) Service life: 10 million cycles. How to Order

Series VCHR. Direct Operated Regulator for 6.0 MPa (Relieving Type) Service life: 10 million cycles. How to Order Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane

More information

Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0.

Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0. 000 Electro-Pneumatic Regulator Electronic Vacuum Regulator Series Series Model Set pressure range Port size Page Series 000 Controls air pressure steplessly in proportion to an electric signal. 0 05 to

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL SMC REULATOR Electro-pneumatic Regulator Electronic Vacuum Regulator Series Series Series Model Regulating pressure range Port size With a simplified high-density circuit board design, an extremely compact

More information

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL Compact Electro-pneumatic Regulator Series For single unit and single unit for manifold Pressure range 9 Option. MPa. MPa.9 MPa kpa Option How to Order N Power supply voltage 24 VDC ±% 2 to VDC Option

More information

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000) 5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust

More information

How to Order ITV N. Nil. EXHc. Base type. Nil. ø1/4"

How to Order ITV N. Nil. EXHc. Base type. Nil. ø1/4 Compact Electro-Pneumatic Regulator Series ITV RoHS How to Order [Option] For single unit and single unit for manifold ITV N Pressure range. MPa. MPa.9 MPa Power supply voltage 4 VDC ±% to VDC Cable connector

More information

Electro-Pneumatic Regulator Electronic Vacuum Regulator

Electro-Pneumatic Regulator Electronic Vacuum Regulator Electro-Pneumatic Regulator Electronic Vacuum Regulator New Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to Series ITV//! Reduced wiring

More information

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators

More information

Series AV2000/3000/4000/5000

Series AV2000/3000/4000/5000 Soft Start-up Valve Series AV/3/4/5 Series introduced! A start-up valve that gradually increases supply pressure during start up and rapidly exhausts system air when the supply air is shut off AC AV AU

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to New Series Reduced wiring Series

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators

More information

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold Compact Electro-Pneumatic Regulator Series ITV How to Order For single unit and single unit for manifold ITV N Q Pressure range. MPa MPa.9 MPa Power supply voltage 4 VDC ±% to VDC Cable connector N S L

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

Clean Regulator. SRH Series. Contamination controlled stainless steel regulator ARJ

Clean Regulator. SRH Series. Contamination controlled stainless steel regulator ARJ Clean Regulator Series IR IRV VEX SRP ITV IC T AP1 Contamination controlled stainless steel regulator 855 Clean Regulator Series Contamination controlled stainless steel regulator Oil free Outstanding

More information

Miniature Regulator. Standard Specifications. Model IN side OUT side (Applicable tubing O.D.) Proof pressure Maximum operating pressure

Miniature Regulator. Standard Specifications. Model IN side OUT side (Applicable tubing O.D.) Proof pressure Maximum operating pressure Miniature Regulator Series 00F Compact and lightweight ( g) Low cracking pressure 0.0 MPa Standard model equipped with backflow function Standard Specifications Port size Fluid side side (Applicable tubing

More information

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot 3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

Manifold Specifications

Manifold Specifications Specifications Specifications Base mounted VVFR-01 VVFR- VVFR-0 Wiring With terminal block With multi-connector With D-sub connector Grommet terminal DIN terminal Grommet Grommet terminal Conduit terminal

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

3 Port Air Operated Valve

3 Port Air Operated Valve Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation

More information

How to Order. Body size

How to Order. Body size Standard Type Series N 00 Over 30 db () noise reduction Low back pressure Compact and easy mounting How to Order N 400 04 Body size 200 300 400 500 600 700 800 900 Thread type Symbol Type Nil R N NPT Symbol

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

Compact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M

Compact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M Compact Vacuum Regulator Series ITV RoHS For single unit and single unit for manifold ITV Pressure range kpa Power supply voltage 4 VDC ±% to VDC How to Order N Cable connector N Without cable connector

More information

Precision Clean Regulator

Precision Clean Regulator Precision Clean Regulator Series AR45 AMR ARM -A VY AP00 High precision, low flow consumption stainless steel regulator 869 Precision Clean Regulator Series High precision, low flow consumption stainless

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

Standard Specifications

Standard Specifications Miniature Regulator ARJ020F Compact and lightweight (6g) Low cracking pressure 0.02MPa Standard model equipped with backflow function Standard Specifications Port size IN side OUT side (Applicable tube

More information

Transmitters: Relay Valve VR4151/4152

Transmitters: Relay Valve VR4151/4152 Relay Valve VR4151/4152 Appropriate output sequences are affected according to the signal received from the mechanical valve. VR4151 VR4152 Precautions Be sure to read before handling. Refer to pages 5-11-2

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

High Pressure Coolant Valve

High Pressure Coolant Valve High Pressure Coolant Valve Series.5 MPa, 7.0 MPa Corresponding to high speed grinding and long drilling processes Coolant valve for high pressure coolant liquid (up to.5 MPa or 7.0 MPa) that is ideal

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry

More information

VCHR Series. Direct Operated Regulator for 6.0 MPa (Relieving Type) Service life: 10 million cycles. How to Order

VCHR Series. Direct Operated Regulator for 6.0 MPa (Relieving Type) Service life: 10 million cycles. How to Order Direct Operated Regulator for 6.0 MPa (Relieving Type) VCHR Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high pressure

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to

More information

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa 5.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator X Series This product is only for blowing gas. This product does not have sufficient pressure control for other applications (driving,

More information

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110 Best 1 Pneumatics Transmitters Relay valve P. 1900 Side piping: 30 x 53 x 91 Bottom piping: 30 x 8 x 91 VR151 VR152 Effective area (mm 2 ) Number of ports Function 7 5 Metal Spool Shuttle valve P. 1902

More information

A variety of circuits in simple construction Intermediate and emergency stops with a large size cylinder

A variety of circuits in simple construction Intermediate and emergency stops with a large size cylinder Power Valve 3 Position Valve Series VEX3 A variety of circuits in simple construction Intermediate and emergency stops with a large size cylinder System construction with VEX Conventional system construction

More information

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal

More information

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum 3 Port Direct Operated Poppet Rubber Seal Series 307 Large Flow Capacity, yet Compact Size. Dimensions (W X H X D) 30 X 54.5 X 33 307 Nl/min 206.02 or more, 1/4 Low Power Consumption /VO307 4.8W DC/Standard

More information

Thread type to 0.8 MPa to 0.8 MPa. Note) Air operated type is model IR2120 only. Note) Air operated type is model IR3120 only.

Thread type to 0.8 MPa to 0.8 MPa. Note) Air operated type is model IR2120 only. Note) Air operated type is model IR3120 only. Precision Regulator Series IR//3 5 Precision Regulator Series IR//3 Features Precise air pressure regulator for instrument applications. Three body sizes available. Pressure unaffected by supply pressure

More information

5 Port Air Operated Valve

5 Port Air Operated Valve Port ir Operated Valve Series VF000/000/000 RoHS 22- Series VF000/000/000 Model Selection by Operating Conditions q ir Operated Valve: Single Unit Series Sonic conductance C[dm /(s bar)] Type of actuation

More information

Manifold Specifications Stacking Type

Manifold Specifications Stacking Type Specifications Stacking Type Keeps environmental air clean from pilot exhaust Use of the VV5FS- manifold can exhaust intensively the pilot exhaust gas to the base side, and can prevent environmental aggravation

More information

ETR Series ELECTRO-PNEUMATIC TRANSDUCING REGULATORS. Electro-Pneumatic Transducing Regulators

ETR Series ELECTRO-PNEUMATIC TRANSDUCING REGULATORS. Electro-Pneumatic Transducing Regulators ELECTRO-PNEUMTIC TRNSDUCING REGULTORS ETR Series Electro-Pneumatic Transducing Regulators fusion of air and electronics Flexibly control pressure. sequencer (PC) allows remote control operation. Feedback

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3

More information

Solenoid Pilot Operated Proportional Directional Control Valve

Solenoid Pilot Operated Proportional Directional Control Valve Solenoid Pilot Operated Proportional Directional Control Valve Features hese solenoid pilot operated proportional directional control valves use a nozzle flapper valve as pilot valve and perform spool

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position

More information

Series ITV1000/2000/3000

Series ITV1000/2000/3000 Electro-Pneumatic Regulator Series ITV// How to Order [Option] RoHS ITV S Model type type type Pressure range 5 MPa MPa.9 MPa CE compliant Nil Q CE compliant Note) Refer to pages, 5, and 6 for information

More information

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Body Ported Base Mounted Series S000 S000 S000 S000 S000 S4000 S5000 Sonic conductance C [dm /s bar)] 4/ 5/(A/B R/R) Single Double.8.4

More information

Flow characteristics Max. (1) b Standard Specifications. P Manual override.

Flow characteristics Max. (1) b Standard Specifications. P Manual override. Port Direct Operated Solenoid Valve Series 0 Metal Seal Model Number of positions (Single) (Double) ( position) JIS Symbol Model Port size Rc (Nominal size) 0-0 8 ( A) 0- ( 8A) 0-0 8 (0A) 0-0 8 ( A) 0-

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

3 Port 3 Position Valve

3 Port 3 Position Valve Port Position Valve Pilot Solenoid ir Operated ohs Intermediate stopping of cylinders * up to ø15 is possible. Pilot solenoid Manifold ir operated * For VEX 4, 00 mm/s, horizontal movement Power consumption:

More information

Series AN /Series AMC

Series AN /Series AMC s/exhaust Cleaner / Noise reduction Nominal filtration rating (Reference values) Oil mist removal ratio Standard type Low back pressure Compact and easy mounting 00 30 db (A) 00 µm 50 µm 5-0- Compact type

More information

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types Speed 2 Port Valve Series RoHS speed speed speed response response response 5 ms 9mm Width ±0.05 ms ±0.05 ms type VCH : : 5 ms * The response time is measured based on SMC test conditions. (Not guaranteed

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

ELECTRO-PNEUMATIC TRANSDUCING REGULATORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS.

ELECTRO-PNEUMATIC TRANSDUCING REGULATORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. CCESSORIES GENERL CTLOG IR TRETMENT, UXILIRY, VCUUM, ND FLUORORESIN PRODUCTS ELECTRO-PNEUMTIC TRNSDUCING REGULTORS CONTENTS ETR Series Features, Operation Principle 237 pplication Examples 238 Handling

More information

Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC

Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC Electric Cylinder LZB/LZC Series It can be operated like an air cylinder. LZB Series LZC Series Model LZB LZC Max. thrust Max. speed 196 N 0 mm/s Lead screw Slide screw: ø8, ø Lead: 2, 6, Stroke 25, 40,

More information

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Soft Start-up Valve. AV2000/3000/4000/5000 Series Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes

More information

Speed Controller with One-touch Fitting

Speed Controller with One-touch Fitting Speed Controller with One-touch Fitting Series Elbow Type Reduces labor time! Elbow Brass Stainless steel Electroless nickel plated Stainless steel 33 RoHS TMH y Easo t e us Push-lock type Larger handle

More information

Rubber Seal VP300/500/700

Rubber Seal VP300/500/700 Port Pilot Operated Poppet Rubber Seal 00/500/700 High flow capacity Cv1.0 (00), Cv. (500), Cv.0 (700) Low power consumption: 1.8W(DC) Possible to use as either selector valve or divider valve Changeable

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

EV2100V Series OUT VAC EV2100V. Specifications. 196kPa 196kPa Control pressure range Assured pressure range Power voltage Current consumption

EV2100V Series OUT VAC EV2100V. Specifications. 196kPa 196kPa Control pressure range Assured pressure range Power voltage Current consumption pneumatic regulator (solenoid type for vacuum) EVV Series JIS symbol EVV CAD DATA AVAILABLE. How to order Overview For electro pneumatic regulator EVV series, feedback control with semiconductor pressure

More information

Vacuum / Release Unit

Vacuum / Release Unit Rubber Seal Vacuum / Release Unit Series VQD1000-V Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area Smooth detachment of a work piece without over-blow

More information

Vacuum Ejector with Solid State Timer

Vacuum Ejector with Solid State Timer Vacuum Ejector with Solid State Timer Incorporates solid state timer function for release valve control (Timer setting with PLC is unnecessary) Timing Chart OFF Suction command ON Suction output OFF ON

More information

Transmitters: Relay Valve

Transmitters: Relay Valve Relay Valve VR5/5 Series Appropriate output sequences are affected according to the signal received from the mechanical valve. It is equivalent to the auxiliary relay of an electrical system. Specifications

More information

3 Port Solenoid Valve

3 Port Solenoid Valve 3 ort Solenoid Valve Series VKF300 ubber Seal Direct Operated oppet Type Compact yet provides a large flow capacity Body width 8 mm vailable in vacuum applications ( 0. ka) Can be used in vacuum/release

More information