Series AV2000/3000/4000/5000
|
|
- Baldric Boyd
- 5 years ago
- Views:
Transcription
1 Soft Start-up Valve Series AV/3/4/5 Series introduced! A start-up valve that gradually increases supply pressure during start up and rapidly exhausts system air when the supply air is shut off AC AV AU AF AR IR VEX SRP AW AMR AWM AWD ITV VA AL Large effective area (mm²) AV/ (ody size: /4) AV3/ 37 (ody size: 3/8) AV4/ 6 (ody size: /) /3 (ody size: 3/4) / (ody size: ) Manual supply/exhaust function Low power consumption Modular with F.R.L. combinations F.R.L. combinations F.R.L. combination Soft start-up valve AV AV3 AV4 Except AC4-6 AC AC5 AC3 AC4 AC5 AC6 SMC F.R.L. combination Soft start-up valve.-
2 Soft Start-up Valve AV/3/4/5 How to Order E AV F C Q Ordering source area code E N Japan, Asia, Australia Europe North Ameria Soft start-up valve Manual override : Non-locking push type (flush type) : Locking type (tool required) C: Locking type (lever type) ody size /4 3/8 / 3/4, Thread type F N Rc NPT Port size /4 (AV only) 3/8 (AV3 only) / (AV4 only) 3/4 ( only) ( only) Option None With pressure gauge Order Made Rated coil voltage * * 3* 4* Indicator light/surge voltage suppressor S Z VAC (5/6Hz) VAC (5/6Hz) to VAC (5/6Hz) VAC (5/6Hz) 4VDC VDC Other * DIN type only. Contact SMC for other voltages (9). None With surge voltage suppressor (grommet type only) With indicator light/surge voltage suppressor (not possible with grommet type) Electrical entry : rommet (only DC voltage) D: Type D DIN terminal How to Order Pilot Valve Assemblies SF4 8 Q Y: Type Y DIN terminal Rated coil voltage * VAC (5/6Hz) * VAC (5/6Hz) 3* to VAC (5/6Hz) 4* VAC (5/6Hz) 5 4VDC 6 VDC 9 Other *DIN Type only Electrical entry D Y rommet Type D DIN terminal Type Y DIN terminal For soft start-up valve Indicator light Surge voltage suppressor S Z Manual override C Non-locking push type (flush type) Locking type (tool required) Locking type (lever type) None With surge voltage suppressor (grommet type only) With indicator light/surge voltage suppressor (not possible with grommet type) TÜV Rheinland AUART EPRÜFT TYPE APPROVED Note) The grommet type can have a surge voltage suppressor (direct coupling type lead wire), but without indicator light. TÜV approved product Conforms to standards necessary to satisfy EC directives. Series AV has received approval from TÜV Rheinland, an EC Notified ody (EC authorization number 97), for conformity to DIN VDE58: 994 Standards. Consult SMC for details when ordering TÜV approved products because of restrictions regarding product model, voltage specification, and electrical entry, etc..-
3 Soft Start-up Valve AV/3/4/5 Specifications Type D DIN terminal Type Y DIN terminal Model Port size Proof pressure Operating pressure range Pressure gauge port size Ambient and fluid temperature Effective area (A) (mm²) (A) Weight (kg) Rated coil voltage Allowable voltage fluctuation Coil insulation type Apparent power Inrush (current AC consumption) Energized Electrical specifications Current consumption DC Electrical entry Optional specification Pilot valve manual override Secondary pressure MPa AV /4 AV3 3/8 AV4 / 3/ ,, to, VAC (5/6Hz),, 4VDC 5% to +% of rated voltage Equivalent to type (3 C) 5.6VA (5Hz), 5.VA (6Hz) 3.4VA (.W)/5Hz,.3VA (.5W)/6Hz.8W rommet, Type D DIN terminal, Type Y DIN terminal Indicator light/surge voltage suppressor Note ) Non-locking push type (flush type), Locking type (tool required), Locking type (lever type) Piston switching pressure (Open Closed) MPa. to MPa /8 to 6 C Note ) Note ) Use dry air when operating at a low temperature. Note ) The grommet type can have a surge voltage suppressor (direct coupling type lead wire), but without indicator light. AC AV AU AF AR IR VEX SRP AW AMR AWM AWD ITV VA AL Primary pressure MPa Symbol Accessories/Pressure gauge Description Part no. Pressure range (A) Pressure gauge 36-- MPa Needle valve flow characteristics Air flow l/min (ANR) Conditions: Primary pressure.5mpa AV4 AV3 AV Needle rotations.-3
4 AV/3/4/5 Working Principle ON - (A) Working condition Low speed supply High speed supply Normal operation Pressure Pilot valve conditions Working description When pilot valve is turned ON by energization or manual override, the pilot air pushes piston A and main valve downward and opens main valve while / PP > R port closes simultaneously. The air from PA P port moves to needle valve, where its flow is adjusted, and flows to A port. The meter-in control of needle valve slowly moves the cylinder from A to. ON When / PP PA after the cylinder reaches, piston fully opens and PA increases rapidly as shown from C to D and / PP PA becomes the same pressure as PP. / PP = approx. PA Pressure time chart (meter-out control) example Initial operation return stroke Pressure stroke A PP PA Cylinder movement with fixed orifice Time C D PR (atmospheric pressure) Since piston holds the fully open condition, during normal operation the cylinder's speed will be controlled by the usual meter-out control. Cylinder drive circuit (meter-out control) example PP PP PA (A) PA (A) Quick exhaust When pilot valve is turned, spring pushes piston A and main valve upward and opens R port while shutting off the air supply from P port. The pressure difference generated at this time opens check valve and the residual pressure on the A port side is quickly exhausted from R port. PP PA (A).-4
5 Soft Start-up Valve AV/3/4/5 Construction AC AV ON - AU AF (A) AR IR VEX SRP AW AMR Parts list No. 3 Description ody Cap Cover Material ADC ADC ADC AWM AWD ITV VA Replacement parts No Description Pilot valve assembly Piston A assembly Piston assembly Main valve assembly Check valve Piston guide assembly Needle assembly Valve spring Piston spring Check spring Needle spring C type snap ring for shaft C type snap ring for hole Seal Seal O-ring Material POM, NR rass, NR (HNR) rass, NR (HNR) rass, NR (HNR) POM, NR rass, NR Steel wire Stainless steel Stainless steel Steel wire Tool steel Tool steel NR NR NR AV P444A P445A P446A P447 P448A P449A P44 P44 P443 P P44 P448 x 8 x Part no. AV3 AV4 SF4- -8 P4434A P4444A P4435A P4445A P4436A P4446A P4437 P4447 P4438A P4448A P4439A P4449A P443 P444 P443 P444 P4433 P4443 P4434 P4444 STW-5 STW-8 - RTW- P443 P444 P4435 P4445 x 9 x.5 x 9.5 x.5 P4454A P4455A P4456A P4457 P4458A P4459A P445 P445 P4453 STW- RTW-5 P445 P x.5 x AL Refer to page.- for pilot valve assembly part number designations..-5
6 AV/3/4/5 Dimensions rommet: AV - -, S D DIN terminal: AV - - D, DZ DIN terminal for European use: AV - - Y, YZ D I - A + SMC MADE IN JAPAN 3mm (lead wire length) Manual override (locking lever type) Applicable heavy duty cord O.D.: ø6, ø8 With indicator light/ surge voltage suppressor Manual override (locking lever type) - + SMC L K A MADE IN JAPAN M Port size ON Pressure gauge mounting bore /8 ø37 P A H Q C N ø37 P ON A Indicator light Q H 36.8 E R P 4-R 36.8 E Pressure gauge mounting bore /8 R P 4-R C Model Port size A C D E H I K L M N P Q R AV- - AV- - S AV- - D AV- - DZ AV- - Y AV- - YZ AV3-3- AV3-3- S AV3-3- D AV3-3- DZ AV3-3- Y AV3-3- YZ AV4-4- AV4-4- S AV4-4- D AV4-4- DZ AV4-4- Y AV4-4- YZ S D DZ Y YZ /4 /4 /4 3/8 3/8 3/8 / / / 3/4, 3/4, 3/4, M4 Depth 4.5 M4 x.7 Depth 4.5 M4 Depth 4.5 M5 Depth 5 M5 Depth 5 M5 Depth 5 Depth 6 Depth 6 Depth 6 Depth 7.5 Depth 7.5 Depth
7 ON Soft Start-up Valve AV/3/4/5 Modular F.R.L. Combination Spacer Select one of the spacers below when connecting to an F.R.L. combination unit (AC to AC6). (Spacers must be ordered separately.) AC IN SMC OUT AV 7 R AU AF AR IR Spacer L type bracket Spacer with L type bracket T type bracket Spacer with T type bracket VEX SRP AW AMR AWM AWD Spacer with L type bracket ITV VA L type bracket Spacer with T type bracket T type bracket Model Y Applicable model AV L type bracket L Spacer with L type bracket YL Applicable model AV T type bracket T Spacer with T type bracket YT Applicable model AV AL Y3 AV3 3L Y3L AV3 3T Y3T AV3 Y4 AV4 4L Y4L AV4 4T Y4T AV4 Y6 6L Y6L 6T Y6T.-7
8 AV/3/4/5 Specific Product Precautions e sure to read before handling. Design. Actuator drive When a component such as a solenoid valve or actuator is to be driven using this product, take appropriate measures to prevent potential danger caused by actuator operation.. Holding of pressure Since the products are subject to air leakage (allowed), they cannot be used for applications such as holding pressure in a pressure vessel. 3. Maintenance space The installation should allow sufficient space for maintenance activities. Selection. Confirm the specifications. The products presented in this catalogue are designed only for use in compressed air systems. Do not operate at pressures or temperatures, etc., beyond the range of specifications, as this can cause damage or malfunction. (Refer to specifications.) Contact SMC when using a fluid other than compressed air.. Extended periods of continuous energization Contact SMC if valves will be continuously energized for extended periods of time. 3. Operation of closed centre solenoid valves When closed center solenoid valves are used, or when used on an actuator with a load factor of 5% or more, jumping (lurching) cannot be prevented even if this product is used. 4. Using a regulator on the secondary side When mounting a regulator on the secondary side (A port side), use a residual pressure relief regulator (AR55 to 45) or a check type regulator (AR56 to 66). With a standard regulator (AR to 6), the secondary side pressure may not be released when this valve is exhausted. 5. Operation of secondary side solenoid valves To operate solenoid valves mounted on this product s secondary side (A port side), first confirm that the secondary side s pressure (P) has increased to become equal to the primary side s pressure (P). 6. Operation The residual pressure release function of this product is for emergency use only; therefore, avoid operation in the same manner as ordinary 3 port valves. 7. Using a lubricator If mounting a lubricator, mount it on the primary side (P port side), of this product. If mounted on the secondary side (A port side), back flow of oil will occur and may spurt out of the valve s R port. 8. Operation for air blowing This product cannot be operated for air blowing due to the mechanism that switches the main valve to be fully open after the secondary side s pressure increases to approximately / of the primary side. Selection. Leakage voltage Particularly when using a C-R element (surge voltage suppressor) for protection of the switching element, take note that leakage voltage will increase due to leakage current flowing through the C-R element, etc. Power supply Switching element Resistor Leakage current AC coil is % or less of rated voltage. DC coil is 3% or less of rated voltage. Valve. Low temperature operation Although the valve can be operated at a temperature as low as C, measures should be taken to avoid solidification or freezing of drainage and moisture, etc. Mounting. If air leakage increases or equipment does not operate properly, stop operation. After mounting or maintenance, etc., connect the compressed air and power supplies, and perform appropriate function and leakage tests to confirm that the unit is mounted properly.. Instruction manual Mount and operate the product after reading the manual carefully and understanding its contents. Also keep the manual where it can be referred to as necessary. 3. Painting and coating s or specifications printed or pasted on the product should not be erased, removed or covered up. Furthermore, contact SMC before painting resin parts, as this may cause adverse effects depending on the solvent. Leakage voltage Adjustment. To perform the initial speed adjustment of a secondary side actuator, supply air from this valve's primary side and turn ON the pilot valve. Then, rotate the needle counter clockwise from the fully closed condition..-8
9 AV/3/4/5 Specific Product Precautions e sure to read before handling. Piping. Preparation before piping efore piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe.. Wrapping of pipe tape When connecting pipes and fittings, etc., be sure that chips from the pipe threads and sealing material do not get inside the valve. Further, when pipe tape is used, leave.5 to thread ridges exposed at the end of the threads. 3. Tighten threads with the proper tightening torque. When screwing fittings into valves, tighten with the torques given below. Tightening torque for piping Connection threads Rc /4 Rc 3/8 Rc / Rc 3/4 Rc Winding direction Expose approx. threads Pipe tape Proper tightening torque N m to 4 to 4 8 to 3 8 to 3 36 to Connection of piping to products When connecting piping to a product, refer to its instruction manual to avoid mistakes regarding the supply port, etc. 5. F.R.L. module combination When connecting to a modular F.R.L. combination (AC to 6), select one of the spacers, which are included. (Refer to page 6 for details.) However, modular combination with AC4-6 is not possible. Furthermore, connect soft start-up valves to the secondary side of the F.R.L. combination. 6. Primary side piping conditions The nominal size of the piping material's or equipment's bore should be equal to or larger than the soft start-up valve's port size. The composite effective area of the primary side's (P port side's) piping or equipment should be equal to or larger than the values below. Indicator Light/Surge Voltage Suppressor Voltage AC and VDC 4VDC or less Electrical circuit Terminal no. (+) Terminal DIN terminal ZNR With indicator light Terminal no. ( ) Electrical Connection DIN terminal Lubrication. The valve has been lubricated for life at the factory, and does not require any further lubrication.. In the event that it is lubricated, use Class turbine oil (without additives), ISO V3. However, once lubrication is applied it must be continued, as the original lubricant may be eliminated leading to malfunction. Contact SMC regarding Class turbine oil (with additives), ISO V3. + Terminal no. + ( ) +( ) (+) ZNR With indicator light Terminal no. (+) Note) There is no polarity (+ or ). The internal connection of the DIN terminal is as shown below, therefore, connect to the power supply side as shown. AC AV AU AF AR IR VEX SRP AW AMR AWM AWD ITV VA AL Model AV AV3 AV4 Composite effective area mm² When the piping is restricted or the supply pressure is insufficient, the main valve will not switch and air leakage may occur from the R port..-9
10 AV/3/4/5 Specific Product Precautions 3 e sure to read before handling. Air Supply. Use clean air. Do not use compressed air which contains chemicals, synthetic oils containing organic solvents, salts or corrosive gases, etc., as this can cause damage or malfunction.. Install air filters. Install air filters close to valves at their upstream side. A filtration degree of 5µm or less should be selected.. Install an after-cooler, air dryer or water separator, etc. Air that includes excessive drainage may cause malfunction of valves and other pneumatic equipment. To prevent this, install an after-cooler, air dryer or water separator, etc. Operating Environment. Do not use valves in atmospheres of corrosive gases, chemicals, salt water, water or steam, or where there is direct contact with any of these.. Do not use in an explosive atmosphere. 3. Do not use in locations subject to vibration or impact. 4. A protective cover, etc., should be used to shield valves from direct sunlight. 5. Shield valves from radiated heat generated by nearby heat sources. 6. Employ suitable protective measures in locations where there is contact with water droplets, oil or welding spatter, etc. 7. In a dusty environment or when valve switching noise is intrusive, take measures for the prevention of dust entry and for noise reduction, such as mounting a silencer on the R port. Maintenance. Perform maintenance procedures as shown in the instruction manual. If handled improperly, malfunction or damage of machinery or equipment may occur.. Equipment removal and supply/exhaust of compressed air When equipment is removed, first confirm that measures are in place to prevent dropping of work pieces and run-away of equipment, etc. Then cut the supply pressure and power, and exhaust all compressed air from the system using its residual pressure release function. 3. Low frequency operation Valves should be switched at least once every 3 days to prevent malfunction. (Use caution regarding the air supply.) 4. Manual override operation When the manual override is operated, connected equipment will be actuated. Confirm safety before operating.. Drainage removal Remove drainage from air filters regularly. (Refer to specifications.) How to Find the Flow Rate (at air temperature of C) Choke flow: when (P +.)/(P +.).5 Q = x S x (P +.) x t Subsonic flow: when (P +.)/(P +.) >.5 Q = 4 x S x (P P)(P +.) x t Q : Air flow rate [l/min (ANR)] S : Effective area (mm²) P: Upstream pressure [MPa] P: Downstream pressure [MPa] t : Air temperature Note) Formulas above apply to compressed air only. Use conventional formulas for water and steam..-
Soft Start-up Valve. AV2000/3000/4000/5000 Series
Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off
More informationAV2000-A/3000-A/4000-A/5000-A
Soft Start-up Valve Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply Power consumption: 0.35 W * At 12/24 VDC
More informationTwo Hand Control Valve
Two Hand Control Valve Series n output is available through synchronized, twohanded operation (within 0.5 s)! Conforming to EN574 RoHS (Interchangeable with XT92-67 ) Example of a basic circuit diagram
More information10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry
Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion
More informationSoft Start-up Valve AV2000/3000/4000/5000
Soft Start-up Valve AV000/3000/4000/5000 F.R.L. AV AU AF AR IR VEX AMR ITV IC VA AV5000 Large effective area (mm ) AV000/ 0 (ody size: /4) AV3000/ 37 (ody size: 3/8) AV4000/ 6 (ody size: /) AV5000/ 3 (ody
More informationCompact Direct Operated 2/3 Port Solenoid Valve for Water and Air
Compact Direct Operated / Port Solenoid Valve for Water and Air 0/0/0: Port, 00/00: Port 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to
More informationITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)*
3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator ITVH Series ARJ RoHS Maximum supply pressure Set pressure range Stability 3.0 MPa 0.2 to 2.0 MPa ARX AMR Stepless control of air
More informationITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa
5.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator X Series This product is only for blowing gas. This product does not have sufficient pressure control for other applications (driving,
More informationNAMUR Interface 5 Port Solenoid Valve
NAMUR Interface 5 Port Solenoid Valve Series VFN000N 5 5 Specifications Valve Electrical entry Fluid Max. operating pressure Min. operating pressure Ambient and fluid temperature Lubrication Pilot operator
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 MPa Pilot Operated /3 Port Solenoid Valve & Check Valve VCH Series VCH4/4: Port VCH40: 3 Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve [Option] VCH40 Series Stable responsiveness Response
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position
More informationPrecision Clean Regulator
Precision Clean Regulator Series AR45 AMR ARM -A VY AP00 High precision, low flow consumption stainless steel regulator 869 Precision Clean Regulator Series High precision, low flow consumption stainless
More informationPower Valve: Economy Valve. Standard Specifications. Model VEX55-04
Three functions (pressure regulator, switching valve, and speed controller) are provided by a single valve. The conventional valve combination circuit has been condensed into a single valve. A large capacity
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion
More informationKV series. Innovatively detachable Manifold Block. Smart Solenoid Valve (plug-in type, D-SUB multi-connector type)
CAT.1101E-S www.sym1.com KV series Innovatively detachable Manifold Block (DIN Rail Mounting) Smart Solenoid Valve (Plug-in type, D-SUB multi-connector ) Compact size with large flow capacity Exceedingly
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model 2 position 3 position
More informationHigh Pressure Coolant Valve
High Pressure Coolant Valve Series.5 MPa, 7.0 MPa Corresponding to high speed grinding and long drilling processes Coolant valve for high pressure coolant liquid (up to.5 MPa or 7.0 MPa) that is ideal
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body
More informationAdded 100 mm and 150 mm lengths. Actuators 10% Air leakage 20% Air blow 70% Current model
Blow Gun Series 20% reduction in power consumption with the SMC Blow gun + S coupler + Coil tube 10% reduction with the Blow gun () only RoHS With cover Extension nozzle Added mm and 150 mm lengths Pressure
More informationStandard Specifications
Miniature Regulator ARJ020F Compact and lightweight (6g) Low cracking pressure 0.02MPa Standard model equipped with backflow function Standard Specifications Port size IN side OUT side (Applicable tube
More informationCoolant valve. SGC/SGH Series
Doc. no. PRODUCT NAME Coolant valve MODEL / Series / Product Number SGC/SGH Series Contents Safety Instructions ------------------------------------------------------------------------------------- 2,3
More informationHow to Order. Nozzle. Nil Connection size N02 N03 F02 F H06 H08 H10 H07 H09 H11
Blow Gun RoHS How to Order VMG W Blow gun Standard type Series Resin body lever type W BU Piping entry Bottom Top Body color White ark blue Symbol Nil 3 4 3 3 4 3 3 33 34 Male High efficiency Low noise
More informationElectro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0.
000 Electro-Pneumatic Regulator Electronic Vacuum Regulator Series Series Model Set pressure range Port size Page Series 000 Controls air pressure steplessly in proportion to an electric signal. 0 05 to
More informationProcess Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero.
For General Purpose /3 Port Valve Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero. Wide variations Series For controlling pneumatic
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body
More informationAir Filter. Best Pneumatics 4. Equipment. Air Line
est Pneumatics Air Filter Air Filter: AF000 to 6000 P..- Mist Separator: AFM000/000/00 P..-6 Micro Mist Separator: AF000/000/00 P..-9 Large Flow Air Filter: AF00/0 P..- Air Line Equipment.-0 Modular Style
More informationSeries VP3145/3165/3185
Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes
More informationSeries VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4
Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double
More informationDoc. no.vn-omm0001-c. Coolant valve PRODUCT NAME. VNC/VNH Series MODEL / Series / Product Number
Doc. no. Coolant valve PRODUCT NAME VNC/VNH Series MODEL / Series / Product Number Contents Safety Instructions ---------------------------------------------------------------------------------- 2,3 Precautions
More informationProcess Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control
Process Series Port For Compressed Air and Air-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Cylinder actuation by external air he balance poppet
More informationElectro-pneumatic Proportional Valve. Specifications. Model Flow type Pressure type VEF2121
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 6-580 www.cmafh.com VEF Port Port Applicable power Body size Body size Electro-pneumatic Proportional
More informationStandard Specifications
Miniature Regulator ARJ020F Compact and lightweight (6g) Low cracking pressure 0.02MPa Standard model equipped with backflow function Standard Specifications Port size IN side OUT side (Applicable tube
More information3/4/5-Port Solenoid Valves Precautions 1 Be sure to read this before handling products.
Precautions 1 1. Confirm the specifications. Products represented in this catalog are designed only for use in compressed air systems (including vacuum). Do not operate at pressures, temperatures, etc.,
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion
More information0.35 W (Without light)
Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:
More informationProcess Valve/Series VN
For General Purpose /3 Port Valve Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero. Wide variations Series VNA For controlling pneumatic
More informationPower Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.
Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control
More informationGrommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC
5 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Body Ported Base Mounted Series S000 S000 S000 S000 S000 S4000 S5000 Sonic conductance C [dm /s bar)] 4/ 5/(A/B R/R) Single Double.8.4
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body
More informationPressure Relief 3 Port Valve With Locking Holes
Doc. No. VH*-OMQ0023-B PRODUCT NAME Pressure Relief 3 Port Valve With Locking Holes MODEL / Series / Product Number VHS20-(F,N)01~02A,B(-B,S)(-K,R,Z) VHS30-(F,N)02~03A,B(-B,S)(-K,R,Z) VHS40-(F,N)02~04A,B(-B,S)(-K,R,Z)
More information5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal
Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage
More information5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range
For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR2 JIS Symbol type
More informationHigh Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series
Doc. No. High Vacuum Solenoid Valve PRODUCT NAME XSA Series MODEL/ Series Thank you for purchasing this SMC product. Be sure to read this Operation Manual carefully and understand its contents before operating
More informationSpeed Controller with Uni One-touch Fitting Push-lock type. New-stand male threads for piping that reduces the screw-in time by 1/3. Model.
Speed Controller with Uni One-touch Fitting Push-lock type Series Elbow Universal Brass New-stand male threads for piping that reduces the screw-in time by 1/3. Gasket Female thread Rc, G NP, NPF Shape
More informationRubber Seal VP300/500/700
Port Pilot Operated Poppet Rubber Seal 00/500/700 High flow capacity Cv1.0 (00), Cv. (500), Cv.0 (700) Low power consumption: 1.8W(DC) Possible to use as either selector valve or divider valve Changeable
More informationPressure Control Equipment
Control High-pressure Precision General Purpose Special Fluid/Deionized Water (Pure Water) Detection Control Control (General purpose, high-pressure, precision, vacuum, special fluid, deionized water (pure
More informationHigh Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series
Doc. No. High Vacuum Solenoid Valve PRODUCT NAME XSA Series MODEL/ Series Thank you for purchasing this SMC product. Be sure to read this Operation Manual carefully and understand its contents before operating
More informationDoc. no.vn -OMA0002-D. Process valve PRODUCT NAME. VNA Series MODEL / Series / Product Number
Doc. no. Process valve PRODUCT NAME VNA Series MODEL / Series / Product Number Contents Safety Instructions ---------------------------------------------------------------------------------- 2,3 Design
More informationExhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)
5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust
More informationAV2000/3000/4000/5000
CAT.ES4-39 Soft Start-up Valve AV/3/4/5 New Series AV5 introduced! A start-up valve that gradually increases supply pressure during start up and rapidly exhausts system air when the supply air is shut
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position
More information1.0 cm 3 /min. Pilot Operated 2-Port Solenoid Valve/ Zero Pressure Differential Operation Series VXS22/23. Compact and Lightweight mm.
Pilot Operated -Port Solenoid Valve/ Zero Pressure Differential Operation Series VXS/ Compact and Lightweight Enclosure: IP65 Low-noise construction Operation noise is reduced due to full wave rectifier
More information5 Port Solenoid Valve
5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry
More informationPower Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.
Power Valve: Regulator Valve Series 1 Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control
More informationStandard Specifications. Model IN side OUT side Fluid Proof pressure Maximum operating pressure
Miniature Regulator Series ARJ1020F 2 Construction/Dimensions Lock nut M8 X 0.75 Panel screw Panel mounting hole Precautions Be sure to read before handling. Refer to pages 14-21-3 to 14-21-4 for Safety
More informationPiping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example
E-P HYREG VY Series This hybrid regulator combines a regulator and a solenoid valve. Stepless control through electric signals Port sizes M5 to inches can be covered by combining an ultra-compact electro-pneumatic
More informationCircuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control
Port Electro-Pneumatic Proportional Valve Series VER000/000 Capable of actuating a cylinder and performing analog control of pressurization VER alone can be used to switch and actuate a cylinder and to
More information5 Port Solenoid Valve Direct Operated Poppet Type. Specifications
Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W
More information2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control
Process Valve Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external pilot
More informationSeries VP3145/3165/3185
Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to
More informationCoolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations
Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) type (3 to ) Low water hammer or details, refer to page 07. Large
More informationRegulator Valve. VEX1 Series
Doc. no. PRODUCT NAME Regulator Valve MODEL / Series / Product Number VEX1 Series Contents Safety Instructions ---------------------------------------------------------------------------------- 2,3 Precautions
More informationRotary Actuators Precautions 1 Be sure to read this before handling.
Precautions 1 1. Confirm the specifications. Products represented in this catalog are designed only for use in compressed air systems (including vacuum). Do not operate at pressures or temperatures, etc.,
More informationDoc. No.VT307 -OMH0001-C. 3 Port Direct Operated Solenoid Valve PRODUCT NAME. VT307 Series MODEL/ Series
Doc. No. 3 Port Direct Operated Solenoid Valve PRODUCT NAME VT307 Series MODEL/ Series Contents Safety Instructions ------------------------------------------------------------------------------- 2,3 Precautions
More information3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot
3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in
More informationCoolant Valve. Air Operated/External Pilot Solenoid
Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) lange type (3 to ) Low water hammer or details, refer to page
More informationVacuum / Release Unit
Rubber Seal Vacuum / Release Unit Series VQD1000-V Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area Smooth detachment of a work piece without over-blow
More informationExclusively for air pressure system and air-hydro circuit control
Process Valve Series Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external
More information13 msec (at 500 mm )/18.5 msec (at 1000 mm )
Vacuum / Release Unit Series VQD1000-V Rubber Seal Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area [Option] Smooth detachment of a work piece without
More informationCompact / Lightweight 2 Port Solenoid Valve
ompact / Lightweight 2 Port Solenoid Valve /-XF For ir/water ompact / Lightweight resin body (PPS) Weight: 20 g (-XF) RoHS IP65 mm Power consumption 3 W (Standard) 0.5 W (With power-saving circuit) 48
More informationISO Standard Solenoid Valve/SIZEq Rubber Seal Series VP7 6
ISO Standard Solenoid Valve/SIZq Rubber Seal Series VP7 6 VP7 6 FPG D VP7 6 FG D position position Single solenoid (FG-S) Double solenoids (FG-D) Reverse pressure (YZ-S) Reverse pressure (YZ-D) Closed
More information5 Port Solenoid Valve Direct Operated Poppet Type. Specifications
Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W
More informationSpeed Controller with One-touch Fitting
Speed Controller with One-touch Fitting S Series Push-lock Type Reduces labor time! Easy to use Easy to lock Unlock Push-lock type Lock Improved tube insertion/removal Max. Insertion force: 30% (8 N) reduction
More informationVacuum pump system type
type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated
More information5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type. Closed Center DS3330/DS3300. How to Order - Body Ported Type
5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type COMPACT SIZE AND LIGHT WEIGHT LARGE FLOW CAPACITY LOW POWER CONSUMPTION DESIGNED FOR NON-LUBRICATED SERVICE DV000 Symbol Single DS330/ How
More informationDirect Operated 3-port solenoid valve
Doc. No. PRODUCT NAME Direct Operated 3-port solenoid valve MODEL/ Series Series: VT315 Contents Safety Instructions --------------------------------------------------------------------------- 2,3 Precautions
More informationISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I
ISO Standard Solenoid Valve Series VQ7-6/7-8 (Size ) (Size ) Conforms to ISO Standard /I.0- Ideal for driving cylinders up to Large flow capacity ø00 (VQ7-6, Size ) ø60 (VQ7-8, Size ) Nl/min VQ7-6: 668.
More informationSpecifications. Fluid Ambient and fluid temperature ( C)
Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication
More informationPilot Operated 2 Port Solenoid Valve for Dry Air
Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible
More informationSpeed Controller with One-touch Fitting
Speed Controller with One-touch Fitting Series Elbow Type Reduces labor time! Elbow Brass Stainless steel Electroless nickel plated Stainless steel 33 RoHS TMH y Easo t e us Push-lock type Larger handle
More informationCircuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control
Port Electro-Pneumatic Proportional Valve Series 000/000 Capable of actuating a cylinder and performing analog control of pressurization alone can be used to switch and actuate a cylinder and to perform
More information3 Port Solenoid Valve
Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series
More informationElectro-Pneumatic Regulator. Standard Specifications. Minimum supply pressure Maximum supply pressure Regulating pressure range
000 Electro-Pneumatic Regulator Series 000/000 Standard Specifications Symbol Straight type Right angle type Model Minimum supply pressure Maximum supply pressure Regulating pressure range Voltage Power
More informationDoc. No.VQ4000V-OMV0001. Solenoid Valve PRODUCT NAME. VQ4000/5000 (Pilot Valve V100) MODEL/ Series
Doc. No. Solenoid Valve PRODUCT NAME VQ4000/5000 (Pilot Valve V100) MODEL/ Series Contents Safety Instructions ---------------------------------------------------------------------------- 2,3 Precautions
More information5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure
For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Series 000 Compact and lightweight: 3 mm width Compact yet provides
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position
More informationTransmitters: Relay Valve VR4151/4152
Relay Valve VR4151/4152 Appropriate output sequences are affected according to the signal received from the mechanical valve. VR4151 VR4152 Precautions Be sure to read before handling. Refer to pages 5-11-2
More informationSeries ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL
SMC REULATOR ITV2 Electro-pneumatic Regulator Electronic Vacuum Regulator Series ITV Series ITV Series Model Regulating pressure range Port size With a simplified high-density circuit board design, an
More informationPilot Operated 2 Port Solenoid Valve for Dry Air
Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0
More informationProcess Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control
Process Valve: Port Valve For Compressed ir and ir-hydro Circuit Control Series VN Style VN -6 VN -8 8 VN - 3 8 VN - 5 VN -5 VN3-0 3 0 Note) This product cannot be used for water application. JIS Symbol
More informationCAT.ES70-22 A. Series VC. Direct Operated 2 Port Solenoid Valve for Heated Water. Series VCB
CAT.ES0- A Series VC Direct Operated Port Solenoid Valve for Heated Water Series VCB Multipurpose Valve for Heated Water Direct Operated Port Solenoid Valve for Heated Water Series VCB Improved durability
More informationCheck Valve Series AK How to Order
High flow capacity Low cracking pressure:.2mpa Check Valve Series AK How to Order N AK 2 2 Compact and light weight Area Code Japan, Asia, Nil Australia, UK N U.S.A. 2 4 6 Body size /4 /2 /8 2 /4 3 3/8
More information1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions
Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]
More information5 Port Pilot Solenoid Valve Metal Seal. Configuration Voltage Electrical entry Option. Standard. 100V AC50/60Hz 200V AC50/60Hz 24V DC.
5 Port Pilot Solenoid Valve Metal Seal SeriesVFS Models and Variations Body ported Base mounted Series VFS000 VFS2000 VFS3000 VFS2000 VFS3000 VFS4000 VFS5000 Port Size Effective area (mm 2 ) (Nl/min) 8:
More informationClean Regulator. SRH Series. Contamination controlled stainless steel regulator ARJ
Clean Regulator Series IR IRV VEX SRP ITV IC T AP1 Contamination controlled stainless steel regulator 855 Clean Regulator Series Contamination controlled stainless steel regulator Oil free Outstanding
More information3 Port Solenoid Valve Direct Operated Poppet Type
3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage
More informationCompact Proportional Solenoid Valve
Compact Proportional Solenoid Valve Series Repeatability: % or less Hysteresis:1% or less Fluid Flow rate control range Note) Series Air, Inert gas to L/min to L/min Note) Varies depending on the model.
More information