1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption
|
|
- Miranda Dorsey
- 6 years ago
- Views:
Transcription
1 Port Solenoid Valve Direct Operated Poppet Type Power consumption Vacuum applications New [Option] RoHS 4 Standard wtype (Existing product: 4.8 W) 0. kpa Energy-saving type.8 w (Existing product: W) A single valve with various valve functions (Universal porting type) N.C. valve Divider valve N.O. valve Selector valve etc Low concentration ozone resistant Rubber seal material: HNBR for main valve Mounting dimensions are interchangeable with existing product 9.5. Body ported type Manifold type Series VT07 CAT.ES-07A
2 Series VT07 Port Solenoid Valve Direct Operated Poppet Type A variety of valve options Continuous duty type Vacuum specification type Energy-saving type Energy-saving type + Vacuum specification type Application examples q Blow-off valve w Pressure release valve e Selector valve r Valve for vacuum (P) (R) (P) (R) X Plug P P (P) (R) Vacuum pump (P) (R) Vacuum pad Vacuum releasing air Atmospheric pressure or micro pressure t Divider valve y Single-acting cylinder drive u Double-acting cylinder drive i Double-acting cylinder drive (Exhaust center) Tank (P) (R) Tank (P) (R) (A) N.C. (P) (R) (P) N.O. (R) N.C. (P) (R) (P) N.C. (R) Port Solenoid Valve, Universal Porting Type Variations Poppet type Direct operated poppet type Pilot poppet type Series New VT07 VT7 VT5 VP00/500/700 Cv (P A) to.6 Refer to the SMC website for details. Features
3 Port Solenoid Valve Direct Operated Poppet Type Series VT07 Rubber Seal RoHS [Option] Note) CE compliant: Electrical entry is applicable only for the DIN terminal. How to Order V T 07 5 G 0 F T O Body type Body ported For manifold Valve option Nil Standard type E Continuous duty type Y Energy-saving type V Vacuum specification type W Energy-saving type, Vacuum specification type Semi-standard Pressure specifications Nil Standard type (0.7 MPa) K High-pressure type ( MPa) Semi-standard Grommet Rated voltage 00 VAC, 50/60 Hz 00 VAC, 50/60 Hz 0 VAC, 50/60 Hz 4 0 VAC, 50/60 Hz 5 4 VDC 6 VDC 7 40 VAC, 50/60 Hz Semi-standard Electrical entry DIN terminal Thread type Nil Rc F G N NPT T NPTF CE-compliant Nil None Q CE-compliant Electrical entry and light/surge voltage suppressor: D/DO/DZ/DOZ only Bracket Nil None F With bracket Port size Nil Without port (For manifold) 0 /8 (6A) 0 /4 (8A) Light/Surge voltage suppressor Nil None With surge voltage suppressor S (Grommet type only) With light/surge voltage suppressor Z (DIN terminal type only) With surge voltage suppressor Surge voltage suppressor G: 00 mm lead wire H: 600 mm lead wire D: With connector JIS Symbol (A) (R) (P) DO: Without connector Manifold Model Applicable manifold type Accessories Function plate (DXT5-4-A) VO07 (-Q) Common or individual exhaust Note) Mounting screw (NXT0-) Note) It is not applicable to the continuous duty type. Refer to the accessories on page 5. Option Description Bracket Part no. DXT5-5-A (With screw)
4 Series VT07 Standard Specifications Make sure that dust and/or other foreign materials do not enter the valve from the unused port (e.g. exhaust port). Flow-rate Characteristics/Weight Type of actuation Fluid Operating pressure range Ambient and fluid temperature Response time Note ) Max. operating frequency Lubrication Mounting orientation Impact/Vibration resistance Note ) Enclosure Electrical entry Coil rated voltage (V) Allowable voltage fluctuation Note ) Note 4) Apparent power AC Note ) Note 4) Power consumption Light/Surge voltage suppressor (DIN terminal type only) Direct operated type position single solenoid Air 0 to MPa (High-pressure type), 0 to 0.7 MPa (Standard type) 0 to 50 C (No freezing) 0 ms or less (at 0.5 MPa) 0 Hz Not required (Use turbine oil Class ISO VG, if lubricated.) Non-locking push type Unrestricted 50/50 m/s Dustproof AC (50/60 Hz) DC Inrush Holding DC AC DC Grommet, DIN terminal 00, 00, 0, 0, 40 4, 5 to +0% of rated voltage.7 VA (50 Hz), 0.7 VA (60 Hz) 7.6 VA (50 Hz), 5.4 VA (60 Hz) Without indicator light: 4 W, With indicator light: 4. W Varistor, LED Diode, LED Semi-standard Note ) Based on dynamic performance test, JIS B (Coil temperature: 0 C, at rated voltage, without surge voltage suppressor) Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Note ) At rated voltage Note 4) The value is different for continuous duty type (VT07E), and energy-saving type (VT07Y/W). Refer to Valve Options shown below. Valve model Flow-rate characteristics Port (P A) (A R) (R A) (A P) size C[dm /(s bar)] b Cv C[dm /(s bar)] b Cv C[dm /(s bar)] b Cv C[dm /(s bar)] b Cv VT07 VT07V (Vacuum spec. type) VT07E (Continuous duty type) /8 VT07Y (Energy-saving type) VT07W (Energy-saving, Vacuum spec. type) VT07 VT07V (Vacuum spec. type) VT07E (Continuous duty type) /4 VT07Y (Energy-saving type) VT07W (Energy-saving, Vacuum spec. type) Note) Values for a single valve unit. It is not applicable to the manifold. Refer to the manifold specifications on page 5. Weight Grommet 0.5 kg Valve Options Continuous duty type: VT07E Exclusive use of VT07E is recommended for continuous duty with long time loading.. This model is for continuous duty, not for high cycle rates. But even in low cycle rates, if energizing the valve more than once a day, please consult with SMC.. Energizing solenoid should be done at least once in 0 days. Specifications different from standard are as follows. Apparent power/ Inrush 7.9 VA (50 Hz), 6. VA (60 Hz) AC Holding 5.8 VA (50 Hz),.5 VA (60 Hz) Power consumption/dc.8 W, With indicator light: W Response time Note) 0 ms or less (at 0.5 MPa) Note) Refer to Note ) of the standard specifications. Energy-saving type: VT07Y (VT07W) If low power consumption is required for electronic control, VT07Y(W) (.8 W) is recommended. Specifications different from standard are as follows. Power consumption/dc.8 W, With indicator light: W Response time Note) 5 ms or less (at 0.5 MPa) Note) Refer to Note ) of the standard specifications. Vacuum spec. type: VT07V (VT07W) This vacuum model has less air leakage than the standard model under low pressure. It is recommended for vacuum application. Since this valve has slight air leakage, it can not be used for vacuum holding (including positive pressure holding) in the pressure container. Specifications different from standard are as follows. Operating pressure range 0. kpa to 0. MPa
5 Port Solenoid Valve Direct Operated Poppet Type Series VT07 Construction De-energized r Energized t Light/Surge Voltage Suppressor AC In the case of indicator light assembly Terminal no. q r y u q Terminal no. DC In the case of indicator light assembly Coil Terminal no. (+) (Å) w e (Â) Operation principle <De-energized> Poppet valve w is pushed upward by the return spring e, port is closed. Then, port and port are connected. Air flow direction: Port Block, Component Parts No. 4 Description Body Poppet valve Return spring Molded coil How to Use DIN Terminal. Disassembly ) After loosening the screw q, then if the housing w is pulled in the direction of the screw q, the connector will be removed from the body of equipment (solenoid, etc.). ) Pull the screw q out of the housing w. ) On the bottom part of the terminal block e, there s a cut-off part o. If a small flat head screwdriver is inserted between the opening in the bottom, terminal block e will be removed from the housing w. 4) Remove the cable gland r, plain washer t and rubber seal y.. Wiring ) Pass the cable u through the cable gland r, plain washer t and rubber seal y in this order, and then insert them into the housing w. ) Loosen the screw! attached to the terminal block e. Then, pass the lead wire!0 through the terminal block e and tighten the screw! again. Note ) Tighten within the tightening torque of 0.5 N m ±5%. Note ) Cable u outside diameter: ø6 to ø8 mm Note ) Crimped terminal like round-shape or Y-shape cannot be used. Connector for DIN Terminal Description DIN connector Part no. BB09-A (Standard) GM09NJ-B7 (CE-compliant) ( ) (Å) ( ) Material Aluminum die-casted Aluminum, HNBR Stainless steel Resin w e (Â) <Energized> When energizing the molded coil r, the armature t is magnetically attracted to the core y, and through the push rod u, it pushes down the poppet valve w and port is closed. Then, port and port are connected. At this time, there will be gaps between the armature t and the core y, but the armature t will be magnetically firmly attracted to the core y. Air flow direction: Port Port, Port Block Note Color: White. Assembly ) Pass the cable u through the cable gland r, plain washer t and rubber seal y in this order and connect to the terminal block e. Then, mount the terminal block e on the housing w. (Push it down until you hear the click sound.) ) Put the rubber seal y and plain washer t in this order into the cable entry of the housing w, and then tighten the cable gland r securely. ) Insert the gasket i between the bottom part of terminal block e and the plug attached to the equipment. Then, screw in q from the top of the housing w to tighten it. Note ) Tighten within the tightening torque of 0.5 N m ±0%. Note ) Connector orientation can be changed 80 depending on how the housing w and the terminal block e are assembled. e i q w o!!0 y t u r Terminal no. ( ) Electrical Connection DIN terminal is connected inside as in the figure below. Connect to the corresponding power supply. DIN terminal block Voltage 00 VAC 00 VAC DC Others Ground Applicable cable O.D. ø6 to ø8 Terminal no. DIN terminal Lead Wire Color Coil + Color Blue Red Red (+), Black ( ) Gray
6 Series VT07 Dimensions Grommet: VT07- G (Non-locking) x ø4.5 (For mounting) (4.5) (4.5) Note) There is also VT07- H (lead wire length: 600 mm). (Non-locking) Applicable cable O.D. ø6 to ø8 (4) () (7.) x ø4.5 (For mounting) (4.5) (4.5) (8) (7) (4.5) Pg9 Max (4) () (7.) (4.5) (8) (7) G: 00 H: 600 (Lead wire length) (.) 6.5. /4", /8" (Piping port) M4 x 0.7 thread depth 7 (Mounting screw) 5 DIN terminal: VT07- D (.) 6.5. /4", /8" (Piping port) 4 M4 x 0.7 thread depth 7 (Mounting screw) 5
7 Series VT07 Manifold Specifications VT07 manifold is available both as a common exhaust and individual exhaust model. Manifold valve can be easily converted from N.C. (Normally Closed) to N.O. (Normally Open) merely by turning over the function plate. Common exhaust VV F Individual exhaust VV F VV07 VT07 manifold How to Order Manifold Base F Dummy symbol Valve stations 0 stations 0 0 stations Max. 0 stations Specify model number of the manifold base, applicable valves and blanking plates when ordering. Refer to page for the model number of the valves. Ordering example: VV F pc. (5 station manifolds base) VO07-G 4 pcs. DXT060-5-A pc. (Blanking plate) Manifold Specifications Manifold type Max. number of stations Applicable solenoid valve Exhaust port Symbol Type Common Individual P Base (Side) 8 Base (Side) A port size (Base mounted) common exhaust/individual exhaust 4 individual exhaust Exhaust port type Common exhaust Individual exhaust Mounting bracket Thread type Nil F N T Rc G NPT NPTF B mount 0 stations Note) VO07 - (-Q) Port location (Direction)/Port size A R Base (Side) Base (Side) 8 8 Base (Side) Base (Top) 4 8, 4 8 Note) For 6 stations or more, supply air both sides of P port. The common exhaust type should exhaust from both of the R port. Option Description Blanking plate (With gasket, screw) Note) Part no. DXT A B Accessories for Applicable Solenoid Valve Description Part no. Qty. Function plate (With gasket) Note) Mounting screws DXT5-4- A B NXT0- pc. pcs. Note) DXT060-5-B, DXT5-4-B are for the continuous duty type. Flow-rate Characteristics/Weight Flow-rate characteristics Valve model (P A) (A R) (R A) (A P) VO07 VO07V (Vacuum spec. type) VO07E (Continuous duty type) C[dm /(s bar)] 0.4 b 0.8 Cv C[dm /(s bar)] 0.4 b 0. Cv 0.08 C[dm /(s bar)] 0.6 b 0.8 Cv 0.09 C[dm /(s bar)] 0.4 b 0.8 Cv VO07Y (Energy-saving type) VO07W (Energy-saving, Vacuum spec. type) Weight Grommet 0.5 kg 5
8 R P Series VT07 Dimensions: Common Exhaust VV F G: 00 H: (Pitch) P = 6 8 L 9 0 L Max. 0 P R DIN terminal (D, DZ) Applicable cable O.D. ø6 to ø8 Pg9 Grommet (G, H) (Non-locking) For 4 x M4 (For mounting) /8" [(P), (R) port] (Station n) (Station ) (5) A A 40 /8" [ port] (Pitch) P = 6 L Dimension L L L n n: Stations Formula L = 6 x n + 6 L = 6 x n + 0 6
9 Port Solenoid Valve Direct Operated Poppet Type Series VT07 Dimensions: Individual Exhaust VV F (Pitch) P = DIN terminal (D, DZ) 8 7 /8" [(R) port] L Applicable cable O.D. ø6 to ø8 Grommet (G, H) (Pitch) P = 6 (Non-locking) 8.5 For 4 x M4 (For mounting) 4.6 R R P () Pg9 0 /4" [(P) port] 8.5 G: 00 H: L (Station n) (Station ) Max A A /4", /8" [ port] (Pitch) P = 6 L Dimension L L L n n: Stations Formula L = 6 x n + 4 L = 6 x n + 7
10 Series VT07 Specific Product Precautions Be sure to read before handling. Refer to back cover for Safety Instructions and Handling Precautions for SMC Products (M-E0-) for /4/5 Port Solenoid Valve Precautions. Warning Mounting When mounting a valve on the manifold base, N.C. and N.O. can be reversed by the function plate orientation. Also, since the cylinder operates in reverse, confirm if the function plate is correctly mounted or not. N.C. specification N.O. specification Changing from N.C. to N.O. This product is delivered as N.C. valve. If N.O. valve is required, remove mounting screws of the required valve and turn over the function plate. (Make sure that there are gaskets on both sides of the plate.) Then, tighten the mounting screws to fix the valve to the manifold base. Port z Port x Port c Port positions for manifold solenoid valve body Function plate Figure: For N.C. Function plate Specifications N.C. N.O. Function plate No mark NO. Each valve is fixed to the manifold base with two M4 mounting screws. Tighten the screws firmly when re-mounting.. For mounting, tighten M4 or equivalent screws evenly into the mounting holes of the manifold base. Tightening torque of the mounting screw (M4):.4 N m Piping. For the common exhaust type, pressurization or evacuation of the (R) port can cause a malfunction. 8
11 Safety Instructions : Warning: Danger : indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of, Warning or Danger. They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) ), and other safety regulations. ) ISO 444: Pneumatic fluid power General rules relating to systems. ISO 44: Hydraulic fluid power General rules relating to systems. IEC 6004-: Safety of machinery Electrical equipment of machines. (Part : General requirements) ISO 08-: Manipulating industrial robots Safety. etc. Warning. The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications. Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment.. Only personnel with appropriate training should operate machinery and equipment. The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced.. Do not service or attempt to remove product and machinery/ equipment until safety is confirmed.. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed.. When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully.. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction. 4. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions.. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight.. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog.. An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation.. The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch. Limited warranty and Disclaimer/ Compliance Requirements The product used is subject to the following Limited warranty and Disclaimer and Compliance Requirements. Read and accept them before using the product. Limited warranty and Disclaimer. The warranty period of the product is year in service or.5 years after the product is delivered, whichever is first. ) Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch.. For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product.. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products. ) Vacuum pads are excluded from this year warranty. A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited warranty. Compliance Requirements. The use of SMC products with production equipment for the manufacture of weapons of mass destruction (WMD) or any other weapon is strictly prohibited.. The exports of SMC products or technology from one country to another are governed by the relevant security laws and regulations of the countries involved in the transaction. Prior to the shipment of a SMC product to another country, assure that all local rules governing that export are known and followed. Safety Instructions Be sure to read Handling Precautions for SMC Products (M-E0-) before using. Akihabara UDX 5F, 4-4-, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: Fax: SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. D-G st printing QW printing QW 850SZ Printed in Japan.
1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions
Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]
More informationLow Torque Metal Seal Type Rotary Joint. MQR Series
Doc. No MQR****-OML0002-A. PRODUCT NAME Low Torque Metal Seal Type Rotary Joint MODEL / Series / Product Number MQR Series Contents 1. Contents P1 2. Model / Specifications P2~5 3. Safety Instructions
More information3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.
3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118
More information3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option
3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity
More information3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option
Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable
More information3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot
3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in
More information3 Port Solenoid Valve Direct Operated Poppet Type
3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage
More informationHigh Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series
Doc. No. High Vacuum Solenoid Valve PRODUCT NAME XSA Series MODEL/ Series Thank you for purchasing this SMC product. Be sure to read this Operation Manual carefully and understand its contents before operating
More informationAS Series. 4.0 g. Weight: Approx. 27% lighter. Flow Rate Reproducibility. Larger Knob. Easy Identification of Product Type. 5.5 g.
Speed Controller with One-touch Fittings In-line In-line Type y Easo t use RoHS Brass Stainless steel Reduces flow setting time! Push-lock type Knob O.D.: Almost doubled! Easy to lock ø9.4 Unlock ø5 Lock
More informationNo.EX -OME0016-A PRODUCT NAME. SI unit. MODEL / Series / Product Number EX140-SDN1
No.EX -OME0016-A PRODUCT NAME SI unit MODEL / Series / Product Number EX140-SDN1 Table of Contents 1. Safety instructions 2 2. Specifications 7 2-1. General specifications 7 2-2. Electrical ant network
More informationPressure Relief 3 Port Valve With Locking Holes
Doc. No. VH*-OMQ0023-B PRODUCT NAME Pressure Relief 3 Port Valve With Locking Holes MODEL / Series / Product Number VHS20-(F,N)01~02A,B(-B,S)(-K,R,Z) VHS30-(F,N)02~03A,B(-B,S)(-K,R,Z) VHS40-(F,N)02~04A,B(-B,S)(-K,R,Z)
More informationDoc. no.vn-omm0001-c. Coolant valve PRODUCT NAME. VNC/VNH Series MODEL / Series / Product Number
Doc. no. Coolant valve PRODUCT NAME VNC/VNH Series MODEL / Series / Product Number Contents Safety Instructions ---------------------------------------------------------------------------------- 2,3 Precautions
More informationHigh Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series
Doc. No. High Vacuum Solenoid Valve PRODUCT NAME XSA Series MODEL/ Series Thank you for purchasing this SMC product. Be sure to read this Operation Manual carefully and understand its contents before operating
More informationThis filter enables direct exhaust of air in a clean room! (Cleanliness class 4*: ISO ) (* Based on SMC s measuring conditions.
Clean Exhaust Filter This filter enables direct exhaust of air in a clean room! (Cleanliness class 4*: ISO14644-1) (* Based on SMC s measuring conditions.) Air can be directly exhausted in a clean room
More informationCoolant valve. SGC/SGH Series
Doc. no. PRODUCT NAME Coolant valve MODEL / Series / Product Number SGC/SGH Series Contents Safety Instructions ------------------------------------------------------------------------------------- 2,3
More information3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum
3 Port Direct Operated Poppet Rubber Seal Series 307 Large Flow Capacity, yet Compact Size. Dimensions (W X H X D) 30 X 54.5 X 33 307 Nl/min 206.02 or more, 1/4 Low Power Consumption /VO307 4.8W DC/Standard
More informationSeries VP3145/3165/3185
Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to
More information3 Port Solenoid Valve
Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series
More information5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal
Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage
More informationSeries VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4
Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double
More information3 Port 3 Position Valve
Port Position Valve Pilot Solenoid ir Operated ohs Intermediate stopping of cylinders * up to ø15 is possible. Pilot solenoid Manifold ir operated * For VEX 4, 00 mm/s, horizontal movement Power consumption:
More informationSeries VP3145/3165/3185
Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes
More information5 Port Solenoid Valve Direct Operated Poppet Type. Specifications
Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body
More informationDoc. no.vn -OMA0002-D. Process valve PRODUCT NAME. VNA Series MODEL / Series / Product Number
Doc. no. Process valve PRODUCT NAME VNA Series MODEL / Series / Product Number Contents Safety Instructions ---------------------------------------------------------------------------------- 2,3 Design
More information5 Port Solenoid Valve Direct Operated Poppet Type. Specifications
Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W
More informationSeries VKF300 VV061 V100 S070 VQD VKF VK VT VS
Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing
More informationDoc. No.VT307 -OMH0001-C. 3 Port Direct Operated Solenoid Valve PRODUCT NAME. VT307 Series MODEL/ Series
Doc. No. 3 Port Direct Operated Solenoid Valve PRODUCT NAME VT307 Series MODEL/ Series Contents Safety Instructions ------------------------------------------------------------------------------- 2,3 Precautions
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body
More informationSpecifications. Fluid Ambient and fluid temperature ( C)
Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body
More informationIndicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A
1 3 Port Air Operated Valve Series VTA301 JIS Symbol VTA 301 Indicate VO for manifold. Port size Specifications How to Order Without connection port (For manifold) 01 1/8 02 1/4 Option Fluid Air Operating
More informationExhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)
5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust
More informationAV2000-A/3000-A/4000-A/5000-A
Soft Start-up Valve Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply Power consumption: 0.35 W * At 12/24 VDC
More informationPilot Operated 2 Port Solenoid Valve for Dry Air
Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0
More informationHigh Vacuum Solenoid Valve. 25% reduction. Max. Weight. 18% * lighter. Max. * XSA2-2 AC 100 V, 200 V, 110 V, 220 V, 240 V, 48 V, 24 V, 230 V DC
Normal lose High Vacuum Solenoid Valve Minimum operating pressure * 1x10 6 Pa(abs) * OUT side Leakage Internal 1.3 x10 9 Pa m3/s Note) Note) Except grommet/ RoHS External 1.3 x10 11 Pa m3/s 2 types of
More information5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure
For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Series 000 Compact and lightweight: 3 mm width Compact yet provides
More information3 Port Air Operated Valve VTA. Indicate VO for manifold. Port size. Nil 02 1/4. Specifications Fluid. Option Description Bracket (With screw)
Series VTA301 How to Order VTA 301 Indicate VO for manifold. Port size Without connection port (For manifold) 01 1/8 02 1/4 F N T Option B Rc G NPT NPTF Without bracket Foot bracket JIS Symbol Specifications
More informationNAMUR Interface 5 Port Solenoid Valve
NAMUR Interface 5 Port Solenoid Valve Series VFN000N 5 5 Specifications Valve Electrical entry Fluid Max. operating pressure Min. operating pressure Ambient and fluid temperature Lubrication Pilot operator
More informationRegulator Valve. VEX1 Series
Doc. no. PRODUCT NAME Regulator Valve MODEL / Series / Product Number VEX1 Series Contents Safety Instructions ---------------------------------------------------------------------------------- 2,3 Precautions
More informationDirect Operated 3-port solenoid valve
Doc. No. PRODUCT NAME Direct Operated 3-port solenoid valve MODEL/ Series Series: VT315 Contents Safety Instructions --------------------------------------------------------------------------- 2,3 Precautions
More informationPilot Operated 2 Port Solenoid Valve for Dry Air
Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible
More informationSpeed Controller with Indicator
Speed Controller with Indicator Numerical indication of handle rotation for flow rate reduces flow setting time and setting errors! Indicator window Body size Body size or larger Indicator window Number
More informationBase Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC
Base Mounted Series VQZ00/00/00 VQZ00/00 / How to Order Valve Made to Order (For details, refer to page 9 and 4.) VQZ 5 5 M Series VQZ00 body width 5 mm VQZ00 body width 8 mm Type of actuation 4 N.C. N.O.
More information69% 30.5 mm 16 mm. Compact Guide Cylinder. Compact. lighter 0.32 kga0.1 kg (Compared with the current MGP-Z series, ø16, 10 mm stroke) Weight
Compact Guide Cylinder ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100 RoHS Compact Overall length shortened New s ø80, ø100 added. Port thread types NPT, G added. Height shortened JMGP ø32 25 mm stroke
More informationFluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single
Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position
More informationDoc. No.VG300 -OMH0002-B. 3 Port Solenoid Valve PRODUCT NAME. VG342 Series MODEL/ Series
Doc. No. 3 Port Solenoid Valve PRODUCT NAME VG342 Series MODEL/ Series Contents Safety Instructions ---------------------------------------------------------------------------- 2,3 Precautions on Design
More informationSeries VQ Port Solenoid Valve
Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors
More informationPower Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.
Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control
More information5 Port Solenoid Valve
5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry
More informationRubber Seal VP300/500/700
Port Pilot Operated Poppet Rubber Seal 00/500/700 High flow capacity Cv1.0 (00), Cv. (500), Cv.0 (700) Low power consumption: 1.8W(DC) Possible to use as either selector valve or divider valve Changeable
More information3 Port Solenoid Valve
3 ort Solenoid Valve Series VKF300 ubber Seal Direct Operated oppet Type Compact yet provides a large flow capacity Body width 8 mm vailable in vacuum applications ( 0. ka) Can be used in vacuum/release
More information0.1 mm. Actuator Position Sensor. D-MP Series. Actuator stroke position is output with an analog signal. Repeatability IP67.
Actuator Position Sensor Actuator stroke position is output with an analog signal. IP67 Repeatability 0.1 mm (Varies depending on the operating conditions.) Analog output 4 measurement ment ranges Voltage
More information3 Port Air Operated Valve
Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation
More information3 Port Solenoid Valve
Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly
More informationFlow characteristics Max. (1) b Standard Specifications. P Manual override.
Port Direct Operated Solenoid Valve Series 0 Metal Seal Model Number of positions (Single) (Double) ( position) JIS Symbol Model Port size Rc (Nominal size) 0-0 8 ( A) 0- ( 8A) 0-0 8 (0A) 0-0 8 ( A) 0-
More information10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry
Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available
More information1.3 x % reduction 18% High Vacuum Solenoid Valve. XSA Series CAT.ES140-7B. 5 to 60 C
Normal lose igh Vacuum Solenoid Valve Minimum operating pressure x0 * 6 Pa(abs) * OUT side * * Excluding grommet/ RoS Leakage Internal.3 x0 9 Pa m3/s External.3 x0 Pa m3/s Max. Max. Power consumption 5%
More informationBody width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.
High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure of 0.5MPa, subject to clean, dry air) 4 Port Direct
More information49.5 mm Overall. 30 mm MXZ ø20. Compact. Compact Cylinder with Linear Guide. MXZ Series CAT.ES20-236A. ø12, ø16, ø20, ø25. MXZ ø20, 10 mm stroke.
Compact Cylinder with Linear Guide ø12, ø16, ø20, ø25 RoHS Compact 49.5 mm Overall length MXZ ø20, 10 mm stroke 30 mm MXZ ø20 Width Design and assembly time is reduced due to integration of a linear guide
More informationDoc. No.VQ4000V-OMV0001. Solenoid Valve PRODUCT NAME. VQ4000/5000 (Pilot Valve V100) MODEL/ Series
Doc. No. Solenoid Valve PRODUCT NAME VQ4000/5000 (Pilot Valve V100) MODEL/ Series Contents Safety Instructions ---------------------------------------------------------------------------- 2,3 Precautions
More informationDoc. No.VQ1000V-OMM0002-B. Solenoid Valve PRODUCT NAME. VQ1000/2000 Series (PILOT VALVE : V100) MODEL/ Series
Doc. Solenoid Valve PRODUCT NAME VQ1000/2000 Series (PILOT VALVE : V100) MODEL/ Series Contents Safety Instructions ---------------------------------------------------------------------------- 2,3 Precautions
More informationMagnetic Field Resistant 2-color Indication Type Solid State Auto Switch
PRODUCT NAME Magnetic Field Resistant 2-color Indication Type Solid State Auto Switch MODEL / Series / Product Number D-P3DW(A) * Series Contents Safety Instructions 2 Model Indication Method 8 Names and
More information(Actual size) 2 switches 10 switches. Push Adjust to the set-value by the or button.
Digital Pressure Switch RoHS compliant Low profile 9.8 mm (Actual size) 13.5 mm 53.4 mm Vertical mounting space reduced to approx.! 1 2 Reduced in depth! 26.1 mm Can copy to up to 1 switches simultaneously.
More informationSeries SV1000/2000/3000/4000
Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double
More information5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range
For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR2 JIS Symbol type
More informationProcess Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control
Process Series Port For Compressed Air and Air-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Cylinder actuation by external air he balance poppet
More informationSolid State Auto Switch D-M9#A#
PRODUCT NAME Solid State Auto Switch MODEL / Series / Product Number D-M9#A# Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product parts 10 Summary of Product parts 10 Definition
More informationVacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm
4 Port Direct Operated Poppet Solenoid Valve Series D1000 High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure
More information0.35 W (Without light)
Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:
More informationHigh Vacuum L Type Valve
Doc. no. PRODUCT NAME High Vacuum L Type Valve MODEL / Series / Product Number XLFV-2 Series Contents Safety Instructions - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2 1. Product Specific Precautions
More information13 msec (at 500 mm )/18.5 msec (at 1000 mm )
Vacuum / Release Unit Series VQD1000-V Rubber Seal Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area [Option] Smooth detachment of a work piece without
More informationPower Valve: Economy Valve. Standard Specifications. Model VEX55-04
Three functions (pressure regulator, switching valve, and speed controller) are provided by a single valve. The conventional valve combination circuit has been condensed into a single valve. A large capacity
More informationRJ M8 size absorption time. Energy (J) RJ-L type. With cap. Short stroke type
Shock Absorber Soft type Stops transported objects softly % reduced absorption time Unique mechanism to achieve a variable sectional area of the fluid channel proportional to the stroke (compared with
More informationHigh Pressure Coolant Valve
High Pressure Coolant Valve Series.5 MPa, 7.0 MPa Corresponding to high speed grinding and long drilling processes Coolant valve for high pressure coolant liquid (up to.5 MPa or 7.0 MPa) that is ideal
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position
More informationGrommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC
5 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Body Ported Base Mounted Series S000 S000 S000 S000 S000 S4000 S5000 Sonic conductance C [dm /s bar)] 4/ 5/(A/B R/R) Single Double.8.4
More informationSI unit for AS-Interface EX250-SAS#
PRODUCT NAME SI unitfor AS-Interface MODEL / Series / Product Number EX250-SAS# Table of Contents Safety Instructions 2 Product Outline 8 Model Indication and How to Order 9 Summary of Product elements
More informationVacuum / Release Unit
Rubber Seal Vacuum / Release Unit Series VQD1000-V Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area Smooth detachment of a work piece without over-blow
More informationDigital Gap Checker. ISA3 series
PRODUCT NAME Digital Gap Checker MODEL / Series / Product Number ISA3 series Table of Contents 1 Before Use Safety Instructions 2 2 About this product Features 7 Model Indication and How to Order 8 Summary
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model 2 position 3 position
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3
More information5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC)
Port Solenoid Valve/Direct Poppet Rubber seal Series VK3000 Nl/min 147 Compact/Width 18 X Length 8 (mm) Low power consumption 4W DC (Standard) 2W DC (Energy saver) Standard copper free specification All
More information45% 6.5 mm. 6 mm. 4 mm. Compact Cylinder. Compact. lighter. JCQ Series CAT.ES20-239C. Weight. ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100
Compact Cylinder ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100 RoHS Compact Both ends tapped mounting added. New s ø80, ø100 added. Port thread types NPT, G added. Overall length shortened 10 mm stroke
More information5 Port Air Operated Valve
Port ir Operated Valve Series VF000/000/000 RoHS 22- Series VF000/000/000 Model Selection by Operating Conditions q ir Operated Valve: Single Unit Series Sonic conductance C[dm /(s bar)] Type of actuation
More informationManual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry
Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal
More informationDoc. no.ck1*-om0066p. PRODUCT NAME Clamp Cylinder. MODEL / Series / Product Number
Doc. no.ck1*-om0066p PRODUCT NAME Clamp Cylinder MODEL / Series / Product Number CK1*40&63-**Z CKG1*40&63-**Z-** CKP1*40&63-**Z-** Contents Safety Instructions P2 1. Specifications P4 1-1. Specifications
More informationExclusively for air pressure system and air-hydro circuit control
Process Valve Series Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external
More informationDigital Flow Switch (Remote type sensor unit)
PRODUCT NAME Digital Flow Switch (Remote type sensor unit) MODEL / Series / Product Number PFM5## Table of Contents Safety Instructions 2 Model Indication and How to Order 10 Summary of Product parts 13
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position
More informationDigital Gap Checker. ISA3 series
PRODUCT NAME Digital Gap Checker MODEL / Series / Product Number ISA3 series Table of Contents 1 Before Use Safety Instructions 2 2 About this product Features 7 Model Indication and How to Order 8 Summary
More informationSoft Start-up Valve. AV2000/3000/4000/5000 Series
Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off
More informationPressure Sensor for General Fluids PSE570/573/574
PRODUCT NAME Pressure Sensor for General Fluids MODEL / Series / Product Number PSE570/573/574 Table of Contents Safety Instructions 2 Model Identification and How to Order 8 Names of Parts of Product
More information(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC
5 Port Pilot Operated Solenoid Valve Metal Seal Series VZS Series Variations Plug-in Type Base Mounted Type (With sub-plate) Non Plug-in Type Base Mounted Type (With sub-plate) Series Sonic conductance
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 MPa Pilot Operated /3 Port Solenoid Valve & Check Valve VCH Series VCH4/4: Port VCH40: 3 Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve [Option] VCH40 Series Stable responsiveness Response
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion
More information2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control
Process Valve Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external pilot
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time
More informationISE7 /7 G Series CAT.ES B. MPa/1.6 MPa 1.0. MPa/2.0 MPa. MPa/10 MPa
3-Screen Display High-Precision Digital Pressure Switch Air General Fluids 1.0 ISE70 ISE71 MPa/1.6 MPa 1.0 ISE70G ISE75G MPa/2.0 MPa 5.0 ISE76G ISE77G MPa/10 MPa It is possible to change the settings while
More informationDoc. no.mx*-omp0038-d PRODUCT NAME AIR SLIDE TABLE. MODEL / Series / Product Number
Doc. no.mx*-omp0038-d PRODUCT NAME AIR SLIDE TABLE MODEL / Series / Product Number MXQ6(A,B)-**Z* MXQ8(A,B,C)-**Z* MXQ12(A,B,C)-**Z* MXQ16(A,B)-**Z* MXQ20(A,B)-**Z* MXQ25(A)-**Z* Contents 1. Pr oduc t
More information