Applicable bore size. CC-Link. EtherNet/IP. Decentralized Serial Wiring. EtherCAT I/O. Serial unit: EX600 IP67 compliant. Serial unit: EX500

Size: px
Start display at page:

Download "Applicable bore size. CC-Link. EtherNet/IP. Decentralized Serial Wiring. EtherCAT I/O. Serial unit: EX600 IP67 compliant. Serial unit: EX500"

Transcription

1 5 Port Solenoid Valve Series C000 Metal Seal Rubber Seal Compact and large flow Type (Series) Manifold pitch (mm) C to ø Note) Flow characteristics: position single, / 5/ (/ R/R) IP67 enclosure compatible Dusttight and immersible type (ased on IEC605) (For kits S, T, L and M) Connector type manifold pplicable to EX600 (Input/Output) serial transmission system (Fieldbus system) vailable for DeviceNet, PROFIUS DP, CC-Link, EtherNet/IP and EtherCT Fieldbus protocols Max. units Note) can be connected in any order. The unit to connect input device such as an auto switch, pressure switch and flow switch, and the unit to connect output device such as a solenoid valve, relay and indicator light can be connected in any order. Note) Except SI unit wide variety of prepackaged wiring configurations F Kit Kit Kit (D-sub connector) P Kit T L M S Kit (Serial transmission) Flow characteristics Note) Metal seal Rubber seal C[dm /(s bar)] b Cv C[dm /(s bar)] b Cv nalogue Input Unit can be connected with analogue input device. s well as a Digital (switch) Input/Output Unit, a unit applicable to analogue signal is provided, and can be connected with various device for control. Self-diagnosis function It is possible to ascertain the maintenance period and identify the parts that require maintenance, by an input (sensor) open circuit detecting function and an input/output signal of ON/OFF counter function. lso, the monitoring of input/output signal and the setting of parameters can be performed with a Handheld Terminal. (Flat ribbon cable) pplicable cylinder size (mm) Outstanding response times and long service life (Metal seal: Single type with light/surge voltage suppressor) C0: 7 ms ± ms; 0 million cycles The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration. ll kits use multi-pin connectors, so switching from the F kit (D-sub connector) to the S kit (serial transmission) can be done simply by changing the kit section. ccommodates gateway-type serial wiring Gateway unit types include DeviceNet, PROFIUS DP, CC-Link, and EtherNet/IP. ecause just one gateway unit controls up to branch lines, it offers much more freedom in choosing valve mounting locations in comparison to other serial units. Manifolds and input blocks can be mounted near the actuator, allowing for use of short air piping or electric wiring. The package wiring with connector cable reduces the potential for incorrect wiring and improves wiring efficiency. single cable from the gateway provides both signal and power to each branch, thus eliminating the need for separate power connections for each manifold valve and input block. The input block also employs a multi-pin connector so that the number of stations can be changed easily, as with the manifold. (Terminal block box) (Lead wire) Kit (Circular connector) SJ J VF VP S C C Z VFS VFR 7 5 core cable 6 pins Protective enclosure conforms to IP 67 5 pins 6 pins, 0 pins Protective enclosure conforms to IP 67 Protective enclosure conforms to IP 67 Protective enclosure conforms to IP 67 Our six standard wiring packages bring a world of ease to wiring and maintenance work, while the protective enclosures of four of them conform to IP67 standards. The S Kit is compatible with a combined I/O unit. (Not applicable to Gateway unit) 7

2 Series C000 ase Mounted: Variations Sonic Conductance C[dm /(s bar)] Values: CYL EXH / 5/ Single/Double position (Closed center) pplicable bore size Compatible network DeviceNet PROFIUS DP CC-Link EtherNet/IP EtherCT I/O Serial unit: EX600 IP67 compliant Gateway application Compatible network DeviceNet PROFIUS DP EtherNet/IP Decentralized Serial Wiring Gateway application requires a gateway unit and communication cable separately. Please contact for more details. Serial unit: EX500 IP67 compliant S Kit Serial transmission Compatible network DeviceNet PROFIUS DP CC-Link EtherCT PROFINET Output Compatible network DeviceNet PROFIUS DP CC-Link S-Interface CNopen EtherNet/IP I/O Serial unit: EX60 IP0 compliant IP67 compliant Serial unit: EX50 IP67 compliant Compatible network CC-Link Output Serial unit: EX6 IP67 compliant Series C000 Metal seal Rubber seal C00 C to ø Cylinder verage Speed Series C000 verage speed (mm/s) Series CJ Pressure 0.5 MPa Load ratio 50% Stroke 60 mm Series CM Pressure 0.5 MPa Load ratio 50% Stroke 00 mm This chart is provided as guidelines only. For performance under various conditions, use 's Model Selection Program before making a judgment. ore size Series M, C Pressure 0.5 MPa Load ratio 50% Stroke 500 mm Values at extension of a directly coupled cylinder when meter-out speed controllers are used with the needle full open. The average speed of the cylinder is obtained by dividing the stroke by the total stroke time. The load ratio is obtained by the following formula: ((Load mass x.)/theoretical output) x 0% Series CS/CS Pressure 0.5 MPa Load ratio 50% Stroke 00 mm ø6 ø ø6 ø0 ø5 ø ø0 ø0 ø50 ø6 ø0 ø0 ø5 ø ø60 Vertically upward Horizontal

3 5 Port Solenoid Valve Series C000 F Kit D-sub connector D-sub connector Compatible D-sub connector ( that complies with) MIL standard. 5pins Conditions P Kit Flat ribbon cable Flat ribbon cable Compatible with ribbon cable (flat that complies connector) with MIL standard. 6pins/0pins T Kit Terminal block box Terminal block box (Terminal blocks) Terminals are concentrated in compact clusters within the terminal block box. ase mounted Series CJ Series CM Series M, C Series CS/CS Tube x Length T060 x m T75 x m T x m C000 Speed controller S00F-06 S00F- S00F- Silencer N0-0 N0-0 ( L Kit Electrical entry Lead wire IP67 enclosure with use of multiple wire cable with sheath and waterproof connector ) M Kit Circular connector Circular connector IP67 enclosure ( ) with use of waterproof multiple connector IP67 compliant IP67 compliant IP67 compliant SUP port EXH, (P, R) Port size Cylinder port, (, ) <SUP port> C (For ø) C (For ø) Rc / C (For ø) N7 (ø/") (NPT, NPTF, G) N (ø5/6") N (ø/") <EXH port> Rc / Rc / Rc / Rc / (ottom ported) (NPT, NPTF, G) (NPT, NPTF, G) SJ J VF VP S C C Z VFS VFR 7 Conditions (With SGP (Stainless steel gas piping)) ody ported Tube x Length C000 Speed controller Silencer Series M, C Series CS/CS SGP x m S0-0 N0-0

4 ase Mounted Plug-in Unit Series C000 How to Order Manifold VV5QC 0 0 TD0 q w e r! F P L T Kit M VV5QC 6 0 SDQW Series C000 ase mounted plug-in Enter EX600-compliant Enter only for S kit y t u i o!0 S Kit Enter EX50-compliant Enter only for S kit q Stations 0 station 6 6 stations The minimum or maximum number of stations differs depending on the electrical entry. (Refer to r) Note) In the case of compatibility with the S kit/s Interface the maximum number of solenoids is as shown below, so please be careful of the number of stations. in/ out: Maximum solenoids in/ out: Maximum solenoids D side stations n U side Stations are counted from station on the D-side. w Cylinder port size C With ø One-touch fitting C With ø One-touch fitting C With ø One-touch fitting 0 Rc / Note) 0 Rc / Note) ottom ported Rc / Note) CM Mixed Note) esides Rc, also compatible with G, NPT/NPTF. Part number displayed is as shown below. e Thread type Nil Rc F G T NPT/NPTF t End plate type (Enter EX600-compliant S kit only.) Nil Without end plate M connector power supply (Max. supply current ) 7/ inch connector power supply (Max. supply current ) Note) Without SI unit, the symbol is nil. y SI unit output polarity SI unit output polarity EX50 integrated-type (for I/O) serial transmission system DeviceNet PROFIUS DP CC-Link S-Interface CNopen EtherNet/IP Nil + COM N COM SI unit output polarity Nil N + COM COM SI unit output polarity Nil N DeviceNet EX60 integrated-type (for output) serial transmission system PROFIUS DP CC-Link SI unit output polarity Nil N + COM COM DeviceNet PROFIUS DP CC-Link Note) Leave the box blank for the SI unit COM without SI unit (SDO). u I/O unit stations (Enter EX600-compliant S kit only.) Nil i Symbol Nil 0 + COM COM EX500 gateway-type serial transmission system DeviceNet EtherCT PROFINET EtherNet/IP EX600 integrated-type (for I/O) serial transmission system (Fieldbus system) With input block With input blocks No. of blocks Without SI unit (SD0) Without input block With input block With input blocks With input blocks PROFIUS DP Note ) Without SI unit, the symbol is nil. Note ) SI unit is not included in I/O unit stations. Note ) When I/O unit is selected, it is shipped separately, and assembled by customer. Refer to the attached operation manual for mounting method. Note ) Refer to page 50 for details of the enclosure. Number of input blocks (Enter only for S kit compliant with EX50) EtherNet/IP o Nil!0 EtherNet/IP Without input block M, inputs M, inputs M, inputs EtherCT Input block COM (Enter only for S kit compliant with EX50) Nil PNP sensor input or without input block N NPN sensor input! Option Nil K N Number of input blocks (Enter only for S kit compliant with EX50) Special wiring specifications (except for double wiring) With name plate (available for T kit only)

5 ase Mounted Series Plug-in Unit C000 SJ r Kit Designation/Electrical Entry/Cable Length S Kit (Serial transmission kit (Fieldbus system) : EX600 integrated-type) S Numbers in parentheses represent the maximum number of solenoids in the case of mixed single and double wiring. The total number of solenoids determines the maximum number of stations. When ordering mixed wiring, please add the option symbol -K. Kit (Serial transmission kit: EX500 gateway-type) S Kit (Serial transmission kit: EX60 integrated-type (I/O)) J IP0 compliant SI unit: EX60 Symbol SI unit: EX600 IP67 compliant IP67 compliant SI unit: EX500 Serial kit without SI unit SD60 Serial kit for DeviceNetTM SD6Q Serial kit for PROFIUS-DP to 6 stations SD6N () Serial kit for CC-LINK SD0 Serial kit without SI unit SD6V Device Net, PROFIUS DP, SD6ZE EtherNet/IP SD EtherCT EtherNet/IP SD6D Kit TM S (Serial transmission kit: EX50 integrated-type (for I/O)) SI unit: EX50 S to 6 stations (6) IP67 compliant SD0 SDQ SDN SDV SDT SDT SDTC Note ) SDTD Note ) SDY SDZEN Kit (Serial transmission kit: EX6 integrated-type (for output)) SD0 SN SN SNC SND SD SD SF SF SE SE IP67 compliant Protocol Number of outputs Communication connector Serial kit without SI unit M DeviceNet 6 M 6 PROFIUS DP D-subNote ) 6 M CC-Link 6 M EtherCT 6 M PROFINET 6 M EtherNet/IP 6 Serial kit without SI unit Serial kit for DeviceNetTM Serial kit for PROFIUS-DP Serial kit for CC-LINK S-i, in/out, slave modes, power supply systems S-i, in/out, slave modes, power supply systems S-i, in/out, slave modes, power supply systems S-i, in/out, slave modes, power supply systems to 6 stations () to stations () to stations () to stations () to stations () For CNopen For EtherNet/IP P Stations to 6 stations () to 6 stations (6) to 6 stations () to 6 stations (6) to 6 stations () to 6 stations (6) to 6 stations () to 6 stations (6) to 6 stations () to 6 stations (6) to 6 stations () to 6 stations (6) to 6 stations () to 6 stations (6) to 6 stations () Kit (Flat ribbon cable kit) VF VP S C C Z VFS VFR 7 IP0 compliant Note) For a 0P flat ribbon cable, the cable assembly must be ordered separately. SI unit: EX6 to 6 stations (6) SDV Serial kit for CC-LINK F Kit (D-sub connector kit) M D-sub connector kit (5P) without cable D-sub connector kit (5P) with.5 m cable to 6 stations () D-sub connector kit (5P) with.0 m cable D-sub connector kit (5P) with 5.0 m cable Kit (Circular connector kit) PDC T Flat ribbon cable kit (6P) without cable Flat ribbon cable kit (6P) with.5 m cable Flat ribbon cable kit (6P) with.0 m cable Flat ribbon cable kit (6P) with 5.0 m cable MD0 MD MD MD Circular connector kit (6P) without cable Circular connector kit (6P) with.5 m cable to 6 stations () Circular connector kit (6P) with.0 m cable Circular connector kit (6P) with 5.0 m cable to 6 stations () to 6 stations () Flat ribbon cable kit (0P) without cable () Kit (Terminal block box kit) IP67 compliant IP0 compliant FD0 FD FD FD IP67 compliant PD0 PD PD PD IP67 compliant TD0 Terminal block box kit to 6 stations (0) L Kit (Lead wire kit) IP67 compliant LD0 Lead wire kit (5 core) 0.6 m lead wire LD Lead wire kit (5 core).5 m lead wire LD Lead wire kit (5 core).0 m lead wire to 6 stations () The maximum number of solenoids displayed in parentheses is applied to the special wiring specification (Option -K ). Note ) When selecting SI units with SDTC or SDTD specifications, there are limits to the supply current from the SI unit to the input block or valve. Refer to page 077 for details. Note ) When selecting D-sub S kit specifications only, IP0 is compatible. (ll other SI units are IP67 compliant.) Note ) For the SI unit part no., refer to page.

6 Series C000 How to Order Valves C Series C000 C D E F Type of actuation SI unit Part No. Table EX600 Symbol position single () () Protocol type SD6Q DeviceNet TM SD6N PROFIUS DP SD6V CC-Link SD6ZE EtherNet/IP TM SD6D EtherCT EX60 Protocol Symbol type 5 (R) (P)(R) position double (metal) () () 5 (R) (P) (R) position double (rubber) () () 5 (R) (P) (R) position closed center () () 5 (R)(P)(R) Number of outputs Serial unit No. COM. (PNP) + COM. (NPN) EX600-SDN EX600-SDN EX600-SMJ EX600-SMJ EX600-SPR EX600-SPR EX600-SEN EX600-SEN EX600-SEC EX600-SEC Serial unit No. COM. (PNP) + COM. (NPN) EX60-SDN EX60-SDN DeviceNet TM 6 EX60-SDN EX60-SDN SN EX60-SPR EX60-SPR SN 6 EX60-SPR EX60-SPR PROFIUS DP SNC EX60-SPR5 EX60-SPR6 SND 6 EX60-SPR7 EX60-SPR EX60-SMJ EX60-SMJ CC-Link 6 EX60-SMJ EX60-SMJ SD EX60-SEC EX60-SEC EtherCT SD 6 EX60-SEC EX60-SEC SF EX60-SPN EX60-SPN PROFINET SF 6 EX60-SPN EX60-SPN SE EX60-SEN EX60-SEN EtherNet/IP SE 6 EX60-SEN EX60-SEN EX6 Symbol Protocol type SDV CC-Link (+ COM.) (NPN) 5 6 Serial unit No. EX6D-SMJ position exhaust center () () 5 (R) (P)(R) position pressure center () () 5 (R) (P) (R) position perfect () () 5 (R)(P)(R) Communication connector M D-sub M M M M Page P. Page P. Page P. Seal type 0 Metal seal Rubber seal C Function Nil R Y D Coil voltage 5 VDC Note) 6 VDC Note) S kit is only available for VDC. EX500 Symbol SD Standard type ( W) External pilot Low wattage type (0.5 W) Note ) When specifying more than one option, enter symbols in alphabetical order. Note ) Please select when you expect to energize the unit for extended periods of time. Refer to page for details. E Light/Surge voltage suppressor Nil With Without light, E with surge voltage supressor Protocol type DeviceNet TM PROFIUS DP EtherNet/IP TM Serial unit No. + COM. (NPN) COM. (PNP) EX500-Q00 F Manual override Nil: Non-locking push type (Tool required) : Locking type (Tool required) EX500-Q Page P. EX50 Symbol Protocol type Serial unit No. Page SDQ SDN SDV DeviceNet TM ( COM.) (PNP) PROFIUS DP ( COM.) (PNP) CC-Link (+ COM.) (NPN) EX50-SDN EX50-SPR EX50-SMJ S-Interface ( COM.) (PNP), ( in/ out, SDT EX50-SS slave modes, power supply systems) S-Interface ( COM.) (PNP), ( in/ out, SDT EX50-SS5 slave modes, power supply systems) P. S-Interface ( COM.) (PNP), ( in/ out, SDTC EX50-SS7 slave modes, power supply systems) S-Interface ( COM.) (PNP), ( in/ out, SDTD EX50-SS slave modes, power supply systems) SDY CNopen ( COM.) (PNP) EX50-SC SDZEN EtherNet/IP TM ( COM.) (PNP) EX50-SEN Refer to page 07 and Operation Manual, for details on the EX600 integrated-type (I/O). Refer to pages, 07, and 055 and Operation Manual for details on the EX500 gateway-type serial transmission system, EX50 integrated-type (I/O) serial transmission system and EX6 integrated-type (for output) serial transmission system respectively. For details about EX60 integrated type (for output), refer to page 06 and Operation Manual. Please download the Operation Manual via 's website,

7 ase Mounted Plug-in Unit Series C000 Manifold Options Refer to the catalog of series 000 for further information of options. lanking plate assembly V000-- Individual SUP spacer Individual EXH spacer V000-P V000-R SUP/EXH block plate V000-6 Throttle valve spacer V Residual pressure release valve perfect spacer V Note ) SUP stop valve spacer V Note ) Perfect spacers with residual pressure release valve cannot be combined with external pilot specifications. <EXH block plate> <SUP block plate> Interface regulator RQ P SJ J VF VP S C C Z VFS VFR 7

8 Series C000 Plug-in Unit Model ase Mounted Symbol position single () () 5 (R) (P)(R) position double (metal) () () 5 (R) (P) (R) position double (rubber) () () 5 (R) (P)(R) position closed center () () 5 (R) (P)(R) position exhaust center () () 5 (R) (P)(R) position pressure center () () 5 (R) (P)(R) position perfect () () 5 (R) (P)(R) Manifold Specifications Series C000 No. of solenoids position position Model Metal seal Single Rubber seal Metal seal Double Rubber seal Closed Metal seal center Rubber seal Exhaust Metal seal center Rubber seal Pressure Metal seal center Rubber seal Metal seal Perfect Rubber seal C0 C C00 C0 C00 C0 C00 C0 C500 C50 C600 C60, (P, ) Flow characteristics Note ) Response time (ms), 5, (, R, R) Standard: W or less or less or less or less or less or less or less or less or less or less.7 55 or less. 6 or less C[dm /(s bar)] b Cv C[dm /(s bar)] b Cv Weight (g) Low wattage or less 0 7 or less or less 60 5 or less 7 or less 5 or less 7 or less 0 5 or less 7 or less 5 or less 57 or less or less Note ) C000: Cylinder port size Rc / Note ) Values represented in this column are based on JIS 75- (operating with clean air and a supply pressure of 0.5 MPa. Equipped with light/surge voltage suppressor. Values vary depending on the pressure as well as the air quality.) Values for double types are when the switch is ON. Standard Specifications Valve specifications Electrical specifications Valve Configuration Fluid Max. operating pressure Note ).0 Min. operating pressure Single Double position Proof pressure mbient and fluid temperature Lubrication Manual override Impact/Vibration resistance Enclosure Rated coil voltage llowable voltage fluctuation Coil insulation type Power consumption VDC (Current) VDC Metal seal Rubber seal ir MPa (0.7 MPa) 0.5 MPa 0. MPa 0.5 MPa 0.5 MPa 0. MPa.5 MPa to 50 C Note ) Not required Push type/locking type (tool required) option 50/0 m/s Note ) Dust proof (IP67 compliant) VDC ±% of rated voltage Equivalent to type W DC ( m), 0.5 W DC ( m) W DC ( m), 0.5 W DC ( m) Note ) Use dry air to prevent condensation at low temperatures. Note ) Impact resistance: No malfunction resulted from the impact test using a drop impact tester. The test was performed one time each in the axial and right angle directions of the main valve and armature, for both energized and de-energized states. Vibration resistance: No malfunction occurred in a one-sweep test between 5 and 000Hz. Test was performed in the axial and right angle directions of the main valve and armature for both energized and de-energized states. Note ) Values in ( ) are for the low wattage (0.5 W) specification. Series ase model Connection type C000 VV5QC- F Kit: D-sub connector P Kit: Flat cable T Kit: Terminal block box S Kit: Serial transmission L Kit: Lead wire M Kit: Circular connector Piping specifications Port Port size Note ) direction, (P, R), (, ) C (For ø) C (For ø) Side P: Rc / C (For ø) R: Rc / Rc / Rc / ottom Note ) One-touch fittings in inch sizes are also available. Note ) n optional specification for special wiring is available to increase the maximum number of stations. Rc / Note ) pplicable stations F, L, M and P kits to 6 stations T kit to 6 stations S kit to 6 stations: EX50 to 6 stations: EX500 pplicable solenoid valves C00-5 C0-5 5 station weight (g) 50 S kit (without unit) Solenoid weight is not included.

9 S C000 kit (Serial transmission): For EX600 Integrated-type (I/O) Serial Transmission System VV5QC S Kit (Serial transmission kit: EX50) Power supply with M connector (6) 7.5 Digital input unit Input connector Power connector FE terminal 6 0 x M Mounting hole End plate Output connector Marker groove 7 m + 66 Digital output unit Communication connector SI unit 7 m 7 / [ (R) port] /: /" Female thread (Rc, G, NPT/NPTF) / [ (P) port] /: /" Female thread (Rc, G, NPT/NPTF) / (External pilot port) /: /" Female thread (Rc, G, NPT/NPTF) ase Mounted L Valve plate L (n ) x 5 Indicator light Manual override Connector for handheld terminal D-side Stations 0.6 / (Pilot EXH port) /: /" Female thread (Rc, G, NPT/NPTF).5 Plug-in Unit 5 6 Series C n R U-side (6.5) 5.7 / / C C C [(), () port] 6.7 IP67 compliant.5 /: /" Female thread (Rc, G, NPT/NPTF) /: /" Female thread (Rc, G, NPT/NPTF) C: ø One-touch fitting C: ø One-touch fitting C: ø One-touch fitting SJ J VF VP S C C Z VFS VFR 7 Formulas L = 5n + 6 L = 5n + L dimension: Without I/O unit For additional I/O unit, add 7 mm. m: I/O unit stations Dimensions L n L 56 L 0 n: Stations (Maximum 6 stations)

10 Series C000 S C000 kit (Serial transmission): For EX600 Integrated-type (I/O) Serial Transmission System VV5QC S Kit (Serial transmission kit: EX600) Power supply with M connector Digital input unit Input connector Digital output unit Output connector 7 m + 66 Communication connector SI unit L L (n ) x 5 Indicator light Manual override IP67 compliant 7.5 (6) m 7 R.5 6 Marker groove Power connector Valve plate FE terminal Connector for handheld terminal x M Mounting hole End plate / [ (R) port] /: /" Female thread (Rc, G, NPT/NPTF) / [ (P) port] /: /" Female thread (Rc, G, NPT/NPTF) D-side Stations n U-side / (External pilot port) /: /" Female thread (Rc, G, NPT/NPTF) / (Pilot EXH port) /: /" Female thread (Rc, G, NPT/NPTF) (6.5) / / C C C [(), () port] /: /" Female thread (Rc, G, NPT/NPTF) /: /" Female thread (Rc, G, NPT/NPTF) C: ø One-touch fitting C: ø One-touch fitting C: ø One-touch fitting Formulas L = 5n + 6 L = 5n + L dimension: Without I/O unit For additional I/O unit, add 7 mm. m: I/O unit stations Dimensions L L L n 0 56 n: Stations (Maximum 6 stations)

11 series VV5QC S Kit (Serial transmission kit: EX500) L L L n SI unit M -pin socket M -pin plug.5 PWR COM EX500 D-side x Rc / External pilot port 0 ase Mounted Stations L L Manual Indicator light override x Rc/ Pilot EXH port Formulas: L = 5n + 6, L = 5n + 5 n: Stations (Maximum 6 stations) P= n x Rc /, /, C, C, C Rc /:/" Female thread Rc /: /" Female thread C : ø One-touch fitting C : ø One-touch fitting C : ø One-touch fitting (), () port Plug-in Unit Series C000 S C000 kit (Serial transmission kit): For EX500 Gateway-type Serial Transmission System IP67 compliant n 7.7 P= U-side (6.5) (6.5) 6 x Rc / (R) port x Rc / (P) port SJ J VF VP S C C Z VFS VFR 7 7

12 Series C000 C000 IP0 compliant S kit (Serial transmission): For EX60 Integrated-type (I/O) Serial Transmission System IP67 compliant VV5QC S Kit (Serial transmission kit: EX60).5 L L (n ) x 5 (6.5) Indicator light Manual override SI unit D-side Stations n U-side <Communication connector D-sub> x Rc/ (R) port x Rc/ (P) port x Rc/ External pilot port x Rc/ Pilot EXH port (6.5) 7 n x Rc/, /, C, C, C (), () port L L L n n: Stations (Maximum 6 stations)

13 ase Mounted Plug-in Unit Series C000 S C000 kit (Serial transmission kit): For EX50 Integrated-type (I/O) Serial Transmission System IP67 compliant VV5QC S Kit (Serial transmission kit: EX50) Input block x M 5.7 x M x M 0 6 SI unit M x Rc / External pilot port 0 US PWR Indicator light x Rc / Pilot EXH port L n x C, C6, C C: ø One-touch fitting C6: ø6 One-touch fitting C: ø One-touch fitting C: ø One-touch fitting C: ø One-touch fitting (), () port L P= D-side Stations n U-side 7.7 P= (6.5) Manual override 6 x Rc / (R) port x Rc / (P) port (6.5) SJ J VF VP S C C Z VFS VFR 7 Formulas: L = 5n + 6, L = 5n + 05 (For one input block. dd mm for each additional input block.) n: Stations (Maximum 6 stations) L n L L

14 Series C000 S C000 kit (Serial transmission kit): For EX6 Integrated-type (Output) Serial Transmission System VV5QC S Kit (Serial transmission kit: EX6) IP67 compliant x M5 Mounting hole L Indicator light Manual override L P= R R SI unit Please use drip proof plug assembly (XT0-0) with unused conduit port (G/). x G / Conduit port D-side Stations n U-side x Rc / (R) port x Rc / (P) port x Rc / External pilot port x Rc / Pilot EXH port n x Rc /, /, C, C, C Rc /: /" Female thread Rc /: /" Female thread C : ø One-touch fitting C : ø One-touch fitting C : ø One-touch fitting (), () port (6.5) L L L n Formulas: L = 5n + 6, L = 5n + n: Stations (Maximum 6 stations)

15 SJ J VF VP S C C Z VFS VFR 7

16 Series C000 F C000 kit (D-sub connector kit) IP0 compliant Using our D-sub connector for electrical connections greatly reduces labor, while it also minimizes wiring and saves space. We use a D-sub connector (5P) that conforms to MIL standards and is therefore widely compatible with many standard commercial models. Top or side entry for the connector can be changed freely, allowing for changes even after mounting, to meet any changing needs for space. Electrical Wiring Specifications D-sub connector Station Station Station Station Station 5 Station 6 Station 7 Station Station Station Station Station (For 5P) Standard wiring s the standard electrical wiring specification used is for stations or less, double wiring (connected to SOL. and SOL. ) is used for the internal wiring of each station regardless of valve and option types. Mixed single and double wiring are available as options. Refer to special wiring specifications (options) below. Lead wire colors for D-sub connector assemblies Connector terminal no. 05 (XT0-DS5-00 ) SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. COM Terminal no Lead wire color lack Yellow rown Pink lue Orange Purple Yellow Gray Pink Orange lue Purple rown Gray Pink Gray lack Yellow Orange Dot marking lack lack lack lack lack Special Wiring Specifications (Options) 050 Mixed single and double wiring are available as options. The maximum number of manifold stations is determined by the number of solenoids. Count one point for a single solenoid type and two points for a double solenoid type. The total number of solenoids (points) must not exceed. Cable ssembly XT0-DS D-sub connector cable assemblies can be ordered with manifolds. Refer to manifold ordering. Lead wire colors for D-sub connector cable assembly terminal numbers L 6 (.).5 m m 5 m XT0-DS5-05 XT0-DS5-00 XT0-DS5-050 Cable 0. mm x 5 core O.D. ø. pprox. ø Seal (length indication) Molded cover x M.6 x 0.5 Connector D-5SF-N manufactured by Japan viation Electronics Industry, Ltd. Socket side Terminal no. D-sub connector cable assemblies Cable length (L) Part no. Note Cable 0. mm x 5 cores When using a standard commercial connector, use a type 5P female connector conforming to MIL-C-0. Cannot be used for transfer wiring. Lengths other than the above is also available. Please contact for details. Terminal no Lead wire color lack rown Orange Yellow Pink lue Purple Gray Yellow Orange Yellow Pink lue Purple Gray Orange rown Pink Gray lack Dot marking lack lack lack lack lack Electrical characteristics Some connector manufacturers: Item Characteristic Fujitsu, Ltd. Conductor resistance 65 or less Japan viation Electronics Industry, Ltd. Ω/km, 0 C J.S.T. Mfg. Co., Ltd. Voltage limit HIROSE ELECTRIC CO., LTD. 00 V, minute, C Insulation resistance 5 or more MΩ/km, 0 C Note) The minimum bending radius for D-sub connector cables is 0 mm. COM

17 F C000 kit (D-sub connector kit) VV5QC pplicable connector: D-sub connector (5P) (Conforms to MIL-C-0) D-sub connector cable assembly (5P) XT0-DS5-05:.5 m XT0-DS5-00: m XT0-DS5-050: 5 m Formulas: L = 5n + 6, L = 5n +.5 n: Stations (Maximum 6 stations) L n L L R0(Min. bending inner radius) IP0 compliant 67 ase Mounted 7 x Rc / Pilot EXH port x Rc / External pilot port Indicator light n x Rc /, /, C, C, C Rc /: /" Female threa Rc /: /" Female threa C : ø One-touch fitting C : ø One-touch fitting C : ø One-touch fitting (), () port Plug-in Unit L L P=5 Manual release for switching connector direction 65.5 D-side Stations n U-side Series C000 (6.5) 6.5 (6.5) 7.7 P= Manual override x Rc / (R) port x Rc / (P) port SJ J VF VP S C C Z VFS VFR 7

18 Series C000 P C000 kit (Flat ribbon cable kit) Using our flat ribbon cable for electrical connections greatly reduces labour, while it also minimizes wiring and saves space. We use flat ribbon cables whose connectors (6P and 0P) conform to MIL standards, and are therefore widely compatible with many standard commercial models. Top or side entry for the connector can be changed freely, allowing for changes even after mounting, to meet any changing needs for space. Electrical Wiring Specifications Flat ribbon cable connector Connector terminal number Double wiring (connected to SOL. and SOL. ) is used for the internal wiring of each station regardless of valve and option types. Mixed single and double wiring are available as options. Refer to special wiring specifications (options) below. Triangle mark indicator position IP0 compliant Cable ssembly 0 XT0-FC - 6 Type 6P flat ribbon cable connector assemblies can be ordered with manifolds. Refer to manifold ordering. 0 (0P) 7.5 (6P) Terminal no. WG Station Station Station Station Station 5 Station 6 Station 7 Station Station Station Station Station <6P> SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. Terminal no Station Station Station Station Station 5 Station 6 Station 7 Station Station <0P> Terminal no. SOL. SOL. SOL. 5 6 SOL. 7 SOL. SOL. SOL. SOL. 5 6 SOL. 7 COM. COM. 0 Cable length (L).5 m m 5 m (5.6) Flat ribbon cable connector assemblies 6P XT0-FC6- XT0-FC6- XT0-FC6- L Part no. 0P XT0-FC0- XT0-FC0- XT0-FC0- When using a standard commercial connector, use a type 6P connector conforming to MIL-C-50 or a type 0P with strain relief. Cannot be used for transfer wiring. Lengths other than the above is also available. Please contact for details. Connector Manufacturers Example: Hirose Electric CO., Ltd. Sumitomo/M Limited Fujitsu, Ltd. Japan viation Electronics Industry, Ltd. J.S.T. Mfg. Co., Ltd. Oki Electric Cable Co., Ltd. COM. COM. 5 6 COM Special Wiring Specifications (Option) COM 6 5 COM (For 6P) (For 0P) COM Mixed single and double wiring are available as options. The maximum number of manifold stations is determined by the number of solenoids. Count one point for a single solenoid type and two points for a double solenoid type. The total number of solenoids (points) must not exceed.

19 P C000 kit (Flat ribbon cable kit) VV5QC pplicable connector: Flat ribbon cable connector (6P) (Conforms to MIL-C-50) Flat ribbon cable connector assembly (6P) XT0-FC6-:.5 m XT0-FC6-: m XT0-FC6-: 5 m x Rc / External pilot port 67 IP0 compliant Formulas: L = 5n + 6, L = 5n +.5 n: Stations (Maximum 6 stations) L n L L ase Mounted Indicator light x Rc / Pilot EXH port n x Rc /, /, C, C, C Rc /: /" Female thread Rc /: /" Female thread C : ø One-touch fitting C : ø One-touch fitting C : ø One-touch fitting (), () port Plug-in Unit L L Manual release for switching connector direction P= D-side Stations n U-side P= Series C (6.5) 6 x Rc / (R) port x Rc / (P) port (6.5) Manual override SJ J VF VP S C C Z VFS VFR 7 5

20 Series C000 T C000 kit (Terminal block box kit) IP67 compliant This kit has a small terminal block inside a junction box. The provision of a G / electrical entry allows connection of conduit fittings. Terminal lock Connection Step. How to remove terminal block cover Loosen the mounting screws (M) and remove the terminal block cover. Mounting screw (M) Terminal block cover Step. The diagram below shows the terminal block wiring. ll stations are provided with double wiring regardless of the valves which are mounted. Connect each wire to the power supply side, according to the markings provided inside the terminal block. M screw Gasket Electrical entry x G / 6 mm Step. How to replace the terminal block cover Securely tighten the screws to the torque shown in the table below, after confirming that the gasket is installed correctly. Proper tightening torque (N m) 0.7 to. pplicable crimped terminal:.5-s,.5y-,.5y-n,.5y-.5 Name plate: V5000-N-T Drip proof plug assembly (for G /): XT0-06 Electrical Wiring Specifications (Conforms to IP67) COM COM The internal wiring is double (connected to SOL. and SOL. ) for all stations regardless of the type of valve or options. Mixed single and double wiring are available as options Station Station Station Station Station 5 Station 6 Station 7 Station Station Station Standard wiring Terminal no. SOL. SOL. SOL. SOL. SOL. 5 5 SOL. 6 6 SOL. 7 7 SOL. SOL. SOL. COM. COM Special Wiring Specifications (Option) Mixed single and double wiring are available as options. The maximum number of manifold stations is determined by the number of solenoids. Count one point for a single solenoid type and two points for a double solenoid type. The total number of solenoids (points) must not exceed 0.. How to order Indicate option symbol "-K" in the manifold part number and be sure to specify station positions for single or double wiring on the manifold specification sheet.. Wiring specifications Connector terminal numbers are connected from solenoid station on the side in the order indicated by the arrows without skipping any terminal numbers COM COM

21 VV5QC ase Mounted T C000 kit (Terminal block box kit) IP67 compliant Plug-in Unit Series C Mounting hole for x M5 x G / Conduit port L 7.5 L Indicator light P= Manual override D-side x Rc / External pilot port x Rc / Pilot EXH port n x Rc /, /, C, C, C Rc / : /" Female thread Rc / : /" Female thread C : ø One-touch fitting C : ø One-touch fitting C : ø One-touch fitting (), () port Stations n U-side 0.5 (6.5) 6 x Rc / (R) port x Rc / (P) port SJ J VF VP S C C Z VFS VFR 7 L L L n Formulas: L = 5n + 6, L = 5n + n: Stations (Maximum 6 stations)

22 Series C000 L C000 kit (Lead wire kit) IP67 compliant Direct electrical entry type. IP67 enclosure is available with use of cables with sheath and waterproof connectors. Electrical Wiring Specifications Lead wire specifications Lead wire 0. mm x 5 core Station Station Station Station Station 5 Station 6 Station 7 Station Station Station Station Station Sheath Colour: Urban white SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. COM. s the standard electrical wiring specification used is for stations or less, double wiring (connected to SOL. and SOL. ) is used for the internal wiring of each station regardless of valve and option types. Mixed single and double wiring are available as options. Refer to special wiring specifications (options) below. Terminal no. Lead wire colour Dot marking lack Yellow lack rown 5 Pink lack 6 lue Orange 7 Purple 5 Yellow Grey 6 Pink Orange lack 7 lue 0 Purple rown Grey lack Pink lack Grey lack Yellow 5 Orange Lead wire length VV5QC 0 C LD 0 Electrical characteristics Item Characteristic Conductor resistance 65 or less Ω/km, 0 C Withstand pressure 00 V, minute, C Insulation resistance 5 or more MΩ/km, 0 C Note) Cannot be used for transfer wiring. The minimum bending radius for cables is 0 mm. Lead wire length m.5 m.0 m Special Wiring Specifications (Option) Mixed single and double wiring are available as options. The maximum number of manifold stations is determined by the number of solenoids. Count one point for a single solenoid type and two points for a double solenoid type. The total number of solenoids (points) must not exceed.

23 L C000 kit (Lead wire kit) IP67 compliant VV5QC x Rc/ External pilot port Lead wire length 0.6 m,.5 m, m 5.7 L L Formulas: L = 5n + 6, L = 5n n: Stations (Maximum 6 stations) L n L L ase Mounted Indicator light P= P= (6.5) D-side Stations n U-side x Rc / (R) port x Rc / (P) port x Rc/ Pilot EXH port n x Rc /, /, C, C, C Rc / : /" Female thread Rc / : /" Female thread C : ø One-touch fitting C : ø One-touch fitting C : ø One-touch fitting (), () port Plug-in Unit Series C000 Manual override 0.5 (6.5) SJ J VF VP S C C Z VFS VFR 7

24 Series C000 M C000 kit (Circular connector kit) IP67 compliant Use of circular connectors helps streamline wiring procedure to save labor. IP67 enclosure is available with use of waterproof multiple connectors. Electrical Wiring Specifications Multiple connector!5 q!!6 r! y o i u Station Station Station Station Station 5 Station 6 Station 7 Station Station Station Station Station Double wiring(connected to SOL. and ) is used for the internal wiring of each staion regardless of valve and option types. Mixed single and double wiring are available as options. Refer to special wiring specifications(options) below. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. COM. COM. Terminal no Special Wiring Specifications (Option) Mixed single and double wiring are available as an option. The maximum number of manifold stations is determined by the number of solenoids. Count one point for a single solenoid type and two points for a double solenoid type. The total number of solenoids (points) must not exceed. Cable ssembly XT0-MC Type 6P circular connector cable assemblies can be ordered with manifolds. Refer to manifolds ordering. L assemblies Cable length (L).5 m m 5 m 05 ø Cable 0.mm x 5C O.D. ø. pprox. ø Seal (Length) Circular connector cable Plug ssembly no. 6P XT0-MC6-05 XT0-MC6-00 XT0-MC6-050 Cannot be used for transfer wiring. Lengths other than the above is also available. Please contact for details. Terminal no. M7 female thread Lead wire colors for circular connector cable assembly terminal numbers Terminal no Lead wire color lack rown Orange Yellow Pink lue Purple Gray Yellow Orange Yellow Pink lue Purple Gray Orange rown Pink Gray lack Dot marking lack lack lack lack lack Electric characteristics Item Property Conductor resistance 65 or less Ω/km, 0 C Voltage limit 00 V, minute, C Insulation resistance 5 or more MΩ/km, 0 C Note) The minimum bending radius of the multiple connector cable is 0 mm.

25 M C000 kit (Circular connector kit) IP67 compliant VV5QC L L L 7.5 Circular connector cable assembly XT0-MC6-05:.5 m XT0-MC6-00: m XT0-MC6-050: 5 m M7 male screw x Rc / External pilot port ase Mounted L L (6.5) Indicator light x Rc / Pilot EXH port P=5 Stations Circular connectors (6 pins) C made by CONINVERS Formulas: L = 5n + 6, L = 5n n: Stations (Maximum 6 stations) n D-side n x Rc /, /, C, C, C Rc / : /" Female thread Rc / : /" Female thread C : ø One-touch fitting C : ø One-touch fitting C : ø One-touch fitting (), () port Plug-in Unit n.7 P= Series C000 7 U-side x Rc / (R) port x Rc / (P) port (6.5) Manual override SJ J VF VP S C C Z VFS VFR 7

26 C000 Series Exploded View of Manifold Housing assembly and SI unit D-side end plate assembly Manifold block assembly U-side end plate assembly EX600 w r q e EX60 y Corresponding kit S(EX600, EX50, EX50 S Kit (Serial) EX500 t u i o! EX6!0! (Flat ribbon cable) F Kit P Kit!!!!7!! (Terminal block) T Kit S Kit (Serial) (D-sub connector)! Corresponding kit L Kit (Lead wire) S(EX500, EX60).L.M!5 Note) There are two kinds of manifold blocks available, stations integrated type and station type. stations integrated type is used for even stations while stations integrated type and station type are combined for odd stations. D side U side M Kit (Multiple connector) stations (Odd number) stations stations station 6 stations (Even number) stations stations stations!6

27 ase Mounted Plug-in Unit Series C000 Manifold ssembly Part No. Housing ssembly and SI Unit/Input lock No. SI unit Digital Input Unit Description Digital Output Unit Digital Input/Output End plate Valve Plate 5 SI unit 6 nalog Input Unit nalog Output Unit nalog Input/Output Unit SI unit Part no. EX600-SDN EX600-SDN EX600-SMJ EX600-SMJ EX600-SPR EX600-SPR EX600-SEN EX600-SEN EX600-SEC EX600-SEC EX600-DXN EX600-DXP EX600-DXNC EX600-DXNC EX600-DXPC EX600-DXPC EX600-DXND EX600-DXPD EX600-DXNE EX600-DXPE EX600-DXNF EX600-DXPF EX600-DYN EX600-DYP EX600-DYNE EX600-DYPE EX600-DYNF EX600-DYPF EX600-DMNE EX600-DMPE EX600-DMNF EX600-DMPF EX600-X EX600-Y EX600-M EX600-ED EX600-ED- EX600-ED EX600-ED- EX600-ZMV EX500-Q00 EX500-Q EX60-SDN EX60-SDN EX60-SDN EX60-SDN EX60-SRP EX60-SRP EX60-SRP EX60-SRP EX60-SRP5 EX60-SRP6 EX60-SRP7 EX60-SRP EX60-SMJ EX60-SMJ EX60-SMJ EX60-SMJ EX60-SEC EX60-SEC EX60-SEC EX60-SEC EX60-SPN EX60-SPN EX60-SPN EX60-SPN EX60-SEN EX60-SEN EX60-SEN EX60-SEN Note DeviceNet PNP (Negative common) DeviceNet NPN (Positive common) CC-Link PNP (Negative common) CC-Link NPN (Positive common) PROFIUS DP (Negative common) PROFIUS DP (Positive common) EtherNet/IP (Negative common) EtherNet/IP (Positive common) EtherCT PNP (Negative common) EtherCT NPN (Positive common) NPN input, M connector, 5 pins ( pcs.), inputs PNP input, M connector, 5 pins ( pcs.), inputs NPN input, M connector, pins ( pcs.), inputs NPN input, M connector, pins ( pcs.), inputs, with open circuit detection PNP input, M connector, pins ( pcs.), inputs PNP input, M connector, pins ( pcs.), inputs, with open circuit detection NPN input, M connector, 5 pins ( pcs.), 6 inputs PNP input, M connector, 5 pins ( pcs.), 6 inputs NPN input, D-sub connector, 5 pins, 6 inputs PNP input, D-sub connector, 5 pins, 6 inputs NPN input, Spring type terminal box, pins, 6 inputs PNP input, Spring type terminal box, pins, 6 inputs NPN output, M connector, 5 pins ( pcs.), outputs PNP output, M connector, 5 pins ( pcs.), outputs NPN output, D-sub connector, 5 pins, 6 outputs PNP output, D-sub connector, 5 pins, 6 outputs NPN output, Spring type terminal box, pins, 6 outputs NPN output, Spring type terminal box, pins, 6 outputs NPN input/output, D-sub connector, 5 pins, inputs/outputs PNP input/output, D-sub connector, 5 pins, inputs/outputs NPN input/output, Spring type terminal box, pins, inputs/outputs PNP input/output, Spring type terminal box, pins, inputs/outputs M connector, 5 pins ( pcs.), -channel input M connector, 5 pins ( pcs.), -channel output M connector, 5 pins ( pcs.), -channel inputs/outputs M connector, 5 pins, Max. supply current M connector, 5 pins, Max. supply current, with DIN rail mounting bracket 7/ inch connector, 5 pins, Max. supply current 7/ inch connector, 5 pins, Max. supply current, with DIN rail mounting bracket Enclosed parts: round head screws (M x 6) pcs., round head screws (M x ) pcs. EX500 NPN (Positive common) EX500 PNP (Negative common) DeviceNet, M connector, outputs PNP (Negative common) DeviceNet, M connector, outputs NPN (Positive common) DeviceNet, M connector, 6 outputs PNP (Negative common) DeviceNet, M connector, 6 outputs NPN (Positive common) PROFIUS DP, M connector, outputs PNP (Negative common) PROFIUS DP, M connector, outputs NPN (Positive common) PROFIUS DP, M connector, 6 outputs PNP (Negative common) PROFIUS DP, M connector, 6 outputs NPN (Positive common) PROFIUS DP, D-sub connector, outputs PNP (Negative common) PROFIUS DP, D-sub connector, outputs NPN (Positive common) PROFIUS DP, D-sub connector, 6 outputs PNP (Negative common) PROFIUS DP, D-sub connector, 6 outputs NPN (Positive common) CC-Link, M connector, outputs PNP (Negative common) CC-Link, M connector, outputs NPN (Positive common) CC-Link, M connector, 6 outputs PNP (Negative common) CC-Link, M connector, 6 outputs NPN (Positive common) EtherCT, M connector, outputs PNP (Negative common) EtherCT, M connector, outputs NPN (Positive common) EtherCT, M connector, 6 outputs PNP (Negative common) EtherCT, M connector, 6 outputs NPN (Positive common) PROFINET, M connector, outputs PNP (Negative common) PROFINET, M connector, outputs NPN (Positive common) PROFINET, M connector, 6 outputs PNP (Negative common) PROFINET, M connector, 6 outputs NPN (Positive common) EtherNet/IP, outputs PNP (Negative common) EtherNet/IP, outputs NPN (Positive common) EtherNet/IP, 6 outputs PNP (Negative common) EtherNet/IP, 6 outputs NPN (Positive common) SJ J VF VP S C C Z VFS VFR 7

28 Series C000 Manifold ssembly Part No. Housing ssembly and SI Unit/Input lock No. Description Part no. EX50-SPR EX50-SMJ EX50-SS EX50-SS5 EX50-SS7 7 SI Unit EX50-SS EX50-SC EX50-SDN EX50-SEN EX50-IE Input block EX50-IE EX50-IE EX50-E End plate assembly EX50-E SI unit EX6D-SMJ Terminal plate VC00-7- D-sub connector housing assembly VC00-F5- Flat ribbon cable housing assembly VC00-P6- VC00-P0- Terminal block box housing assembly VC00-T0- VC00-L Lead wire housing assembly VC00-L5-- VC00-L5-- 6 Multiple connector housing assembly VC00-M6- Note PROFIUS DP PNP (Negative common) CC-LinkNPN (Positive common) S-Interface, in/ out, slave modes, power supply systems PNP (Negative common) S-Interface, in/ out, slave modes, power supply systems PNP (Negative common) S-Interface, in/ out, slave modes, power supply system PNP (Negative common) S-Interface, in/ out, slave modes, power supply system PNP (Negative common) CNopen PNP (Negative common) DeviceNet PNP (Negative common) EtherNet/IP PNP (Negative common) M, inputs M, inputs M, inputs Direct mounting DIN rail mounting CC-Link NPN (Positive common) For EX6 SI unit mounting F kit, 5 pins P kit, 6 pins P kit, 0 pins T kit L kit with 0.6 m lead wire L kit with.5 m lead wire L kit with.0 m lead wire M kit 6 pins

29 ase Mounted Plug-in Unit Series C000 Manifold ssembly Part No. D-side end plate assembly!7d-side end plate assembly part no. VC000- Thread type Nil F T Kit type F, P, T, S (EX6, EX50, EX600) kit L, M, S (EX60, EX500) kit U-side end plate end plate assembly part no. VC Thread type Nil F T Rc G NPT/NPTF Rc G NPT/NPTF Manifold block assembly!manifold block assembly part no. VC000- D C6 C Type For station For stations Note ) Note ) Tie-rods ( pcs.) for additional stations included. Note ) ottom ported type is available only for station. Wiring Specifications D Double wiring S Single wiring Replacement parts Pilot valve assembly C000 ZP--!Tie-rod assembly part no. ( units) C000 VC000-TR- Note ) Please order when reducing the number of manifold stations. When increasing the number of stations, additional orders are not required since they are included in the manifold block assembly. Note ) Number of stations, 0 to 6 Thread type (Thread port only) Nil Rc F G T NPT/NPTF Port size Symbol Port size C For ø C For ø C For ø N7 For ø/" N For ø5/6" N For ø/" 0 Rc /" 0 Rc /" Rc /" bottom ported : side (Indicator light: Orange) : side (Indicator light: Green) E: Without indicator light (In common for side and side) 5: VDC 6: VDC Nil: standard ( W) Y : Low wattage (0.5 W) SJ J VF VP S C C Z VFS VFR 7 5

30 Series C000 Specific Product Precautions e sure to read this before handling. Refer to front matter 5 for Safety Instructions and pages to for //5 Port Solenoid Valve Precautions. Warning Since connected equipment will operate when the manual override is activated, confirm that conditions are safe prior to activation. Push type (tool required) is standard, and locking type (tool required) is optional. C000 Push type (Tool required) ore ø5 Manual Override Push down the manual override button with a small screwdriver, etc., until it stops. The manual override will return when released. Replacing One-touch Fittings Cylinder port fittings are available in cassette type and can be replaced easily. Fittings are secured with a retaining clip that is inserted from the top side of the valve. fter removing the valve,remove the clip with a flat head screw driver to replace the fittings. To mount a fitting, insert the fitting assembly until it stops and reinsert the retaining clip to its designated position. Clip Locking type (Tool required) <Option> ore ø5 Push down the manual override button with a small flat head screwdriver or with your finger until it stops, and turn it clockwise 0 to lock it. Turn it counterclockwise to release it. Fitting ssembly Valve Mounting Proper tightening torque (N m) 0. to. PUSH TURN LOCK fter confirming that the gasket is installed correctly, securely tighten the mounting screws according to the tightening torque shown below. Mounting screw (M) pplicable tube O.D. ø ø ø ø/" ø5/6" ø/" Fitting assembly part no. C000 V C V C V C V N7 V N V N Installation and Removal of Light Cover Installation/Removal of light cover Removal Open the cover by inserting a small flat head screwdriver into the slot on the side of the pilot assembly (see drawing below), lift the cover out about mm and then pull off. If it is pulled off at an angle, the pilot valve may be damaged or the protective O-ring may be scratched. Installation Place the cover straight over the pilot O-ring assenmbly so that the pilot valve is not Light cover touched,and push it until the cover hook locks without twisting the protective O-ring. (When pushed in, the hook opens and locks automatically.) 6

F Kit. D-sub. connector. D-sub. connector) Compatible network DeviceNet PROFIBUS DP. CC-Link. Compatible D-sub connector. Output

F Kit. D-sub. connector. D-sub. connector) Compatible network DeviceNet PROFIBUS DP. CC-Link. Compatible D-sub connector. Output Series VQC000 ase Mounted: Variations 5 Port Solenoid Valve Series VQC000 Sonic Conductance C[dm /(s bar)] Values: CYL EXH / 5/ Single/Double position (Closed center) pplicable bore size Compatible network

More information

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Series VQ Rubber Seal Space-saving profile Clean space saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Rubber Seal Series VQ Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Port Solenoid Valve Metal Seal Rubber Seal Series Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000 D-sub Connector J Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000//000 Number of connectors: pins MIL-C-08 Conforming to JIS-X-0 --6 For details

More information

VQ1000. How to Order Manifold. Kit type

VQ1000. How to Order Manifold. Kit type - - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold

More information

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000

More information

Fieldbus System (Output device for driving 5 port solenoid valves)

Fieldbus System (Output device for driving 5 port solenoid valves) Fieldbus System (Output device for driving port solenoid valves) New Compact 8mm (ctual size) Space-saving Installation IP67 RoHS EtherNet/IP added! For units with D-sub connector, and when connected to

More information

Conforms to ISO Standard Size 18 mm, 26 mm Plug-in Type. 5 Port Solenoid Valve

Conforms to ISO Standard Size 18 mm, 26 mm Plug-in Type. 5 Port Solenoid Valve Conforms to IO 0- tandard ize mm, mm Plug-in Type Port olenoid Valve eries V -/V - R R [Option] eries V R- eries V R- Conforms to IO 0- tandard IO tandard: Interface conforming to mm size (V -) and mm

More information

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications Series -SQ00 Port Solenoid Valve Plug-in Unit [Option] How to Order Manifold Electrical entry F kit D-sub connector kit P kit SSQ 08 FD Kit type Flat ribbon cable connector kit J kit Flat ribbon cable

More information

How to Order Manifold. Kit type L8 B4 B6 B8 LM

How to Order Manifold. Kit type L8 B4 B6 B8 LM 0 Stations station VVQ Series VQ000 The maximum and minimum number of are varied depending on. (Refer to the table below.) Series VQ000 ase Mounted Plug-in Unit Manifold Plug-in unit 08 C Cylinder port

More information

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve CT.E- ase Mounted Type Series VQ Port Metal Seal/Rubber Seal Solenoid Valve dvanced manifold va the new age of factory au ase Mounted Type Space saving profile Clean space saving design with all pilot

More information

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 0 PW COM Rubber Seal Port Solenoid Valve Series SZ000 Cassette Type Manifold The plug-in cassette system makes valve replacement easy. plug-in manifold has been created with a height of. mm (including

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and

More information

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring Type4 SY000/000 ase Mounted Monifold Stacking Type/DIN ail Mounted Individual Wiring How to Order Manifold SSY 4 0 U C6 How to Order Valve Manifold ssembly Ordering example SY000 SY000 Valve stations 02

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308 Cable ppendix Cable ppendix Multi-way cables The multi-pole connector cables used on SMC valves are common across several ranges. Cables are available in accordance with the MIL standard C-08 and also

More information

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Fieldbus System (Gateway Decentralized Type)

Fieldbus System (Gateway Decentralized Type) Fieldbus System (Gateway Decentralized Type) * * Except the SY, VQC and S0700 valves GW Unit which supports PROFINET added. New M connector type Input Unit added. Decentralized valve installation Valves

More information

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type20P 5 Port Solenoid Valve ody Ported Manifold ar Stock Type/Flat Ribbon Cable Series SY3000/5000/7000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 5 20P 05 Manifold series 3 SY3000

More information

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position

More information

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles ort Solenoid Valve: ase Mounted Metal Seal/Rubber Seal Series Space and capacity saving ilot valve is gathered at one side. Space saving design which does not have any protrusions. Space saving Capacity

More information

Series SV1000/2000/3000/4000

Series SV1000/2000/3000/4000 Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double

More information

SMC guide to ATEX compliant products

SMC guide to ATEX compliant products SMC guide to ATEX compliant products P-E13-23A A ATEX Directive Directive 94/9/EC Equipment and Protective Systems intended for use in potentially Explosive Atmospheres Outline of ATEX directive Since

More information

New Concept Connector Type Manifold

New Concept Connector Type Manifold New Concept Connector Type Manifold Series /000/3000/000 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration.

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series

More information

Base Mounted Plug-in Unit

Base Mounted Plug-in Unit For details about certified products conforming to international standards, visit us at www.smcworld.com. Plug-in Unit SI unit COM N VVQC VVQC C C C6 M CM 6 B B B6 B M Series VQC Manifold model Plug-in

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

Series SY3000/5000 How to Order Manifold

Series SY3000/5000 How to Order Manifold Type N ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN Rail Mounted/Connector ox SY/ How to Order Manifold SSY SY SY Specifications Symbol Specifications With connector box (COM spec.) N With

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry

More information

Base Mounted Plug-in/Plug Lead: Single Unit

Base Mounted Plug-in/Plug Lead: Single Unit ase mounted VQ ase Mounted lug-in/lug Lead: Single Unit Model Number of solenoids Model Single Metal seal VQ Rubber seal VQ ouble Metal seal VQ Rubber seal VQ Closed Metal seal VQ VQ center Rubber seal

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Body Ported Base Mounted Series S000 S000 S000 S000 S000 S4000 S5000 Sonic conductance C [dm /s bar)] 4/ 5/(A/B R/R) Single Double.8.4

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type1P Type2P 5 Port Solenoid Valve ase Mounted Manifold ar Stock Type/Flat Ribbon Cable Series /5000/000 How to Order Manifold Type 1P/Compact style SS5Y 5 1P 05 C8 Manifold series 3 5, port size Thread

More information

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer Base Mounted Metal Seal/Rubber Seal VQ Built-in silencer, direct exhaust Space-saving profile All pilot valves are compactly mounted on one side. The space-saving design of mounting all fittings on one

More information

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection Rubber Seal Port Solenoid Valve Series SJ000/000 Cassette Type Manifold 0 mm 7. mm (SJ000) 0 mm (SJ000) Non plug-in type Individual wiring manifold SJ000 SJ000 Can be mounted together. Connecter connection

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type. Series -S00 ompact Direct Operated Port Solenoid Valve ontrol Valves ase mounted ody ported lean Series lean Series V S R oil voltage 24 VD VD VD VD VD Power consumption Pressure specification Flow rate

More information

5 Port Solenoid Valve Plug Lead Type

5 Port Solenoid Valve Plug Lead Type 5 Port Solenoid alve Plug Lead Type Series Body Ported Flow rate characteristics For single/double solenoid C [dm 3 /(s bar)]: 0.6 Single Unit alve width: 7.4 mm Possible to drive cylinders: Up to ø32

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve ubber Seal / ort Solenoid Valve Series 000 / 000 / 000 [Option] SJ SY SV SZ V S000 VQ VQ VQ VQC VQZ SQ VFS VF VQ Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread

More information

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I ISO Standard Solenoid Valve Series VQ7-6/7-8 (Size ) (Size ) Conforms to ISO Standard /I.0- Ideal for driving cylinders up to Large flow capacity ø00 (VQ7-6, Size ) ø60 (VQ7-8, Size ) Nl/min VQ7-6: 668.

More information

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating / ort Solenoid Valve ubber Seal Series SYJ000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Specifications JIS Symbol port port (manifold) position

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series

More information

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing

More information

Series VQZ1000/2000/3000 Single Unit

Series VQZ1000/2000/3000 Single Unit +- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body

More information

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A Type N SY/ ase ounted anifold Stacking Type/DIN Rail ounted Connector ox How to Order anifold SSY SY SY Specifications Symbol Specifications With connector box (CO spec.) N With connector box ( CO spec.)

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series VZS Series Variations Plug-in Type Base Mounted Type (With sub-plate) Non Plug-in Type Base Mounted Type (With sub-plate) Series Sonic conductance

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to

More information

Plug Lead Unit: Flip Type

Plug Lead Unit: Flip Type Series ody orted lug Lead Unit: Flip Type For details about certified products conforming to international standards, visit us at www.smcworld.com. 0 Series Kit/Electrical entry/cable length F kit (D-sub

More information

Non-Contact Sensor for Workpiece Placement Verification

Non-Contact Sensor for Workpiece Placement Verification ir Catch Sensor Series 2 Non-Contact Sensor for Workpiece Placement Verification Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3

More information

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is. Port Solenoid Valve Series VQ 00 Unprecedented high speed, stable response, and extra-long service life. ON:.ms, OFF: ms, Dispension accuracy ±ms (With indicator light and surge voltage suppressor; supply

More information

0.35 W (Without light)

0.35 W (Without light) Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position

More information

Gateway Type Serial Transmission System

Gateway Type Serial Transmission System P99-EX-B Gateway Type Serial Transmission System P Maximum 8 point control (64 inputs/64 outputs) P Flexibility of manifold valve installation improved with 4 branch wiring Flexible installation and removal

More information

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Vacuum Release Valve with Restrictor Series SJ3A6 SJ Plug-in Type Connector Connection P.86 D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Non Plug-in Type Individual

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 044 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000 racket

More information

Series PCW. PC Wiring System

Series PCW. PC Wiring System CT.ES0-0 PC Wiring System Series PCW The PC wiring system is a revolutionary new system that simplifies wiring between a PLC and all types of connected equipment. revolutionary new wiring system... 4VDC

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry TEX Compliant Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 44 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000

More information

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal Port Solenoid Valve Cassette Type Manifold Rubber Seal 7.mm (SJ000) SJ000 SJ000 Can be mounted together. 0mm (SJ000) Connector connection New New cable type manifold is added! New Additional options are

More information

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000) 5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model 2 position 3 position

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve CT.ES8 / ort Solenoid Valve Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M.7 to M2. 앬 Flow Characteristics Series Cover (stainless

More information

Terminal Block Box (Spring Type) SY3000/5000/7000 Series

Terminal Block Box (Spring Type) SY3000/5000/7000 Series INFORMATION 5 ort olenoid alve Terminal lock ox (pring Type) Y3000/5000/7000 eries Compact RoH Height 6.7 mm shorter (Approx. 9% reduction) Installation area of the terminal block box Reduced by approx.

More information

Example. U side. Stations SY5000

Example. U side. Stations SY5000 45 Type 5 ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN ail Mounted/Individual Wiring Series SY3000/5000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 3 45 05 U C6 Example

More information

How to Order Manifold. Option Symbol

How to Order Manifold. Option Symbol Series Plug Lead nit For details about certified products conforming to international standards, visit us at www.smcworld.com. Series/Manifold 12 Stations 01 1 station Kit/Electrical entry/cable length

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M. V3 Cover

More information

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles Port Solenoid Valve: ase Mounted Metal Seal/Rubber Seal Series VQ Space and capacity saving Pilot valve is gathered at one side. Space saving design which does not have any protrusions. Space saving Capacity

More information

CAT.E152-5 Port Solenoid Valve/Body Ported Cassette Type Manifold. Series SZ3000

CAT.E152-5 Port Solenoid Valve/Body Ported Cassette Type Manifold. Series SZ3000 CAT.E- Port Solenoid Valve/Body Ported Cassette Type Manifold Series SZ000 The plug-in cassette system makes valve replacement easy. A plug-in manifold has been realized having a manifold height of.mm

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Rubber Seal Port Solenoid Valve Series Manifold Single Unit ase Mounted Manifold VV01 V100 ar base P.18 ody Ported P.10 ase Mounted P.10 VQD VKF VK VT VS Separable base ody Ported Manifold P.1 Stacking

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold Port Solenoid Valve VV00 Series Highly Integrated Unit Manifold po ted - pera irect-o d station es on rt valv ally ividu Ind wired n be ve ca val d. adde ector Con-inn connection) lug (For p ø connection

More information

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit CT.EUS8 UK ower Consumption / ort Solenoid Valve With ower Saving Circuit Series SYJ000/000/7000 Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid alve Plug Lead Type RoHS New Body Ported Flow-rate characteristics For single/double solenoid C [dm 3 /(s bar)]: 0.6 Single Unit alve width: 7. mm Possible to drive cylinders: Up to ø32

More information

3 Port 3 Position Valve

3 Port 3 Position Valve Port Position Valve Pilot Solenoid ir Operated ohs Intermediate stopping of cylinders * up to ø15 is possible. Pilot solenoid Manifold ir operated * For VEX 4, 00 mm/s, horizontal movement Power consumption:

More information

Single Valve/Sub-plate Type IP67 Compliant 90-SV Series

Single Valve/Sub-plate Type IP67 Compliant 90-SV Series Single Valve/Sub-plate Type IP7 Compliant -SV Series SV 00 W U aterial restriction Series -SV000 -SV000 Thread type c F G N NPT T NPTF A B SOL.a SOL.a Type of actuation position single (EA) (P)(EB) position

More information

3 Port Solenoid Valve

3 Port Solenoid Valve 3 ort Solenoid Valve Series VKF300 ubber Seal Direct Operated oppet Type Compact yet provides a large flow capacity Body width 8 mm vailable in vacuum applications ( 0. ka) Can be used in vacuum/release

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information