Conforms to ISO Standard Size 18 mm, 26 mm Plug-in Type. 5 Port Solenoid Valve

Size: px
Start display at page:

Download "Conforms to ISO Standard Size 18 mm, 26 mm Plug-in Type. 5 Port Solenoid Valve"

Transcription

1 Conforms to IO 0- tandard ize mm, mm Plug-in Type Port olenoid Valve eries V -/V - R R [Option] eries V R- eries V R- Conforms to IO 0- tandard IO tandard: Interface conforming to mm size (V -) and mm size (V -) Accommodates IP enclosure. Dust-tight/Water-jet-proof R R Compact and high flow Rubber seal V R- ize mm (ingle) V - ize mm (ingle) R Flow rate C [dm /(s bar)].. Mass 0 g g CAT.E-0A

2 NEW CONCEPT NEW CONCEPT A wide variety of prepackaged wiring configurations Conforms to IO 0- tandard Port olenoid Valve/Plug-in Type kit (erial transmission) F kit (D-sub connector) P kit (Flat ribbon cable) T kit (Terminal block box) kit (ead wire) M kit (Circular connector) eries VR -/VR - IO tandard: Interface conforming to mm size (V R -) and mm size (V R -) Outstanding high-speed response and long service life IP enclosure compatible Dust-tight/Water-jet-proof (Metal seal: ingle type, with light/surge voltage suppressor) (/T//M kit) (Based on IEC0) pins eries Manifold pitch (mm) V- (Metal seal) VR- V- (Metal seal) VR (Rubber seal) The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration. All kits use multi-pin connectors, so switching from the F kit (D-sub connector) to the kit (serial transmission) can be done simply by changing the kit section. A AB COM Max. units Note) can be connected in any order. Exhaust center : VR--FDAG-D VR--FDAG-D Pressure center : VR--FDBG-D VR--FDBG-D I unit for I/O R A P Model Analog Input Unit can be connected with analogue input device. B R B side ymbol VR--FDAG-D VR--FDAG-D N.C. valve VR--FDBG-D VR--FDBG-D N.O. valve VR--FDCG-D VR--FDCG-D N.C. valve N.C. valve (R) (B) (P) (A) elf-diagnosis function Features A side (A) As well as a Digital (switch) Input/Output Unit, a unit applicable to analogue signal is provided, and can be connected with various device for control. It is possible to ascertain the maintenance period and identify the parts that require maintenance, by an input (sensor) open circuit detecting function and an input/output signal of ON/OFF counter function. Also, the monitoring of input/output signal and the setting of parameters can be performed with a Handheld Terminal. tation ingle wiring (Rubber seal only) Note) Except I unit tation Double wiring Two -port valves built into one body The -port valves on the A and B sides can operate independently. When used as -port valves, only half the number of stations is required. Can also be used as a -position, -port type valve. The unit to connect input device such as an auto switch, pressure switch and flow switch, and the unit to connect output device such as a solenoid valve, relay and indicator light can be connected in any order. tation ingle wiring Applicable to EX00 (Input/ Output) serial transmission A -position dual -port valves Note) Values for CY. EXH. (,, ) Applicable to DeviceNet, PROFIBU DP and CC-ink fieldbus protocols A B (Refer to the connector wiring diagram.) Printed circuit board patterns between connectors are shifted at every station. This allows for viable connections to take place without necessarily specifying whether the manifold station is double, single, or mixed wiring. Up to ø00 IP enclosure compliant Output 0 tation Double wiring Up to ø0 IP enclosure compliant Connector wiring diagram (Mixed wiring) Connector type manifold Flow-rate Note) Applicable characteristics cylinder bore size (mm) C b Cv (Rubber seal) Connector IP enclosure compliant Our six standard wiring packages bring a world of ease to wiring and maintenance work, and the four wiring types (/T//M) are compatible with the IP enclosure. Compact and high flow pins -core cable IP enclosure compliant V-: 0 msec or less, service life 00 million cycles V-: 0 msec or less, service life 00 million cycles pins erial transmission EX00 N.O. valve (R) (B) (P) (A) N.O. valve (R) (R) (R) (B) (P) (R) Features

3 Base Mounted: Variations Conforms to IO 0- tandard Port olenoid Valve/Plug-in Type eries V R-/V R- onic conductance C [dm /(s bar)] kit erial transmission F kit D-sub connector P kit Flat ribbon cable T kit Terminal block box kit Electrical entry M kit Circular connector Port size / / A/B EA/EB ingle/double -position (Closed center) Applicable cylinder bore size Gateway application Compatible network DeviceNet PROFIBU DP CC-ink EtherNet/IP Decentralized erial Wiring Gateway application requires a gateway unit and communication cable separately. Please contact MC for details. erial unit: EX00 Compatible network DeviceNet PROFIBU DP CC-ink A-Interface CANopen ControlNet EtherNet/IP I/O erial unit: EX0 Compatible network DeviceNet PROFIBU DP CC-ink I/O erial unit: EX00 IP compliant Compatible network CC-ink Output erial unit: EX IP compliant D-sub connector Conforming to Conforming to ( MI D-sub MI flat ribbon connector ) ( cable connector ) pins pins Flat ribbon cable Terminal block box (Terminal block) Terminal block is compactly arranged on one side. ead wire IP enclosure with use of multiple wire cable with sheath and waterproof connector ( ) ( ) ( ) -core cable Circular connector IP enclosure with use of waterproof circular connector pins IP compliant IP compliant IP compliant UP port EXH, (P, R) Cylinder port, (A, B) IP compliant IP compliant eries V R- Metal seal Rubber seal V- VR-.... Up to ø0 P., P., P., 0 P., P., P., P., P., P., /" /" eries V R- Metal seal Rubber seal V- VR-.... Up to ø00 P., P., P., 0 P., P., P., P., P., P., /" /" /"

4 Conforms to IO 0- tandard Port olenoid Valve/Plug-in Type eries V -/V - R R How to Order Manifold [Option] 0 0 VV 0 ymbol B 0B ize ize mm ize mm tations station stations Port size ide ported /" ide ported /" ide ported /" Bottom ported /" Bottom ported /" Nil 0 DQ NN W Cylinder port size ize mm ize mm Thread type Nil Rc T NPTF F G Note) Note) Conforms to IO- Kit type/electrical entry/cable length (Refer to page ) End plate (Enter EX00-compliant kit only.) Without I unit/end plate M connector power supply (Max. supply current A) / inch connector power supply (Max. supply current A) Number of input blocks (Enter EX0/00-compliant kit only.) Nil 0 Input block type (Enter EX0-compliant kit only.) Nil Input block specification (Enter EX0-compliant kit only.) Nil N Without input block M, inputs M, inputs M, inputs Without I unit/input block Without input block With input block PNP or without I unit/input block NPN CE compliant Nil Q CE compliant Option Nil pecial wiring specifications K (Except double wiring) Direct exhaust with built-in silencer R External pilot M Note) mm and mm sizes mixed Note) Refer to pages and for details of option M. With input blocks I unit COM I unit COM Nil +COM N COM I unit COM Nil +COM N COM I unit COM Nil N +COM COM EX0 integrated-type (I/O) serial transmission system DeviceNet PROFIBU DP CC-ink A-Interface CANopen ContorlNet EtherNet/IP EX00 gateway-type serial transmission system EX DeviceNet PROFIBU DP CC-ink EtherNet/IP CC-ink EX00 integrated-type (I/O) serial transmission system DeviceNet PROFIBU DP CC-ink

5 VVR-A.qxd 0.. :0 PM Page Conforms to IO 0- tandard Port olenoid Valve/Plug-in Type Kit type/electrical entry/cable length eries VR-/VR- Numbers in parentheses represent the maximum number of solenoids in case of mixed single and double wiring. The maximum number of stations is determined by the total number of solenoids. When ordering mixed wiring, please add the option symbol -K. kit (erial transmission: EX00 integrated type (I/O)) kit (erial transmission: EX00 gateway type) I unit: EX00 D0 DQ DN DV I unit: EX00 Without I unit DeviceNet PROFIBU DP CC-ink Note) A separate gateway unit and communication cable are required. to stations () D0 Without I unit DA DeviceNet, PROFIBU DP, CC-ink, EtherNet/IP Without I unit DeviceNet PROFIBU DP CC-ink DTA to DTB stations Note ) () DTC DTD Note ) kit (erial transmission: EX integrated type (Output)) F I unit: EX DVB CC-ink FD0 FD to stations FD () FD IP compliant kit (Terminal block box) IP0 compliant A-Interface, in/ out, slave modes, power supply systems A-Interface, in/ out, slave modes, power supply systems A-Interface, in/ out, slave modes, power supply systems A-Interface, in/ out, slave modes, power supply systems to stations () to stations () to stations () to stations () to stations () PD0 PD PD PD M kit (ead wire) IP0 compliant Flat ribbon cable (P) without cable Flat ribbon cable (P) with. m cable Flat ribbon cable (P) with.0 m cable Flat ribbon cable (P) with.0 m cable IP compliant TD0 Terminal block box to 0 stations (0) D0 D D IP compliant ead wire ( cores) 0. m lead wire ead wire ( cores). m lead wire ead wire ( cores).0 m lead wire to stations () MD0 MD MD MD to stations () kit (Circular connector) pins -core cable to stations () kit (Flat ribbon cable) pins IP0 compliant D-sub connector (P) without cable D-sub connector (P) with. m cable D-sub connector (P) with.0 m cable D-sub connector (P) with.0 m cable IP compliant DY CANopen DZCN ControlNet (IP0) Note ) DZEN EtherNet/IP P kit (D-sub connector) pins T to stations () kit (erial transmission: EX0 integrated type (I/O)) I unit: EX0 D0 DQ DN DV IP compliant IP compliant Circular connector (P) without cable Circular connector (P) with. m cable to stations Circular connector (P) with.0 m cable () Circular connector (P) with.0 m cable The maximum number of stations displayed in parentheses is applied to the special wiring specifications. (Option -K ) Note ) When selecting I units with DTC or DTD specifications, there are limits to the supply current from the I unit to the input block or valve. Refer to the operation manual for details. Note ) When selecting I units with DZCN specifications only, IP0 is compatible. (All other I units are IP compliant.)

6 eries V R-/V R- How to Order Valve (IO0-) V R FG V Z eal type R Rubber Metal CE compliant Nil Q CE compliant ize ize mm ize mm Internal/External pilot Nil Internal pilot R External pilot Type of actuation FG -position FHG -position closed center FJG -position exhaust center FIG -position pressure center FDAG Note) -position dual -port (N.C. + N.C.) FDBG Note) -position dual -port (N.O. + N.O.) FDCG Note) -position dual -port (N.C. + N.O.) Note) Rubber seal only Number of solenoids D Double Note) ingle Note) ingle solenoid is available with -position only. Rated voltage Individual pilot exhaust VDC VDC ight/surge voltage suppressor Nil Z Manual override Nil Push type B ocking type (Tool required) Note) With indicator light / surge voltage suppressor Note) Not applicable to the kit.

7 Conforms to IO 0- tandard Port olenoid Valve/Plug-in Type eries V R-/V R- tandard pecifications ymbol -position single (A)(B) (R) (P)(R) -position double (Metal) (A)(B) (R) (P)(R) -position double (Rubber) (A)(B) (R) (P)(R) -position closed center (A)(B) (R) (P)(R) -position exhaust center (A)(B) (R) (P)(R) -position pressure center (A)(B) Valve specifications Electrical specifications Valve type Fluid Maximum operating pressure Minimum operating pressure Ambient and fluid temperature ubrication Manual override Impact/Vibration resistance Enclosure Rated coil voltage Allowable voltage fluctuation Type of coil insulation Power consumption (Current) ingle Double -position -position VDC VDC Metal seal Air, Inert gas.0 MPa 0. MPa 0. MPa 0. MPa 0 to 0 C Note ) Rubber seal 0. MPa 0. MPa 0. MPa 0. MPa Note ) to 0 C Not required (Non-lube) Push type (Tool required)/ocking type (Tool required) 0, 0 ms Note ) IP (Dust-tight/Water-jet-proof) VDC, VDC ±0% of rated voltage Equivalent to Class B W DC ( ma) W DC ( ma) Note ) Use dry air to prevent condensation at low temperatures. Note ) Impact resistance: No malfunction resulted during an impact test using a drop impact tester. The test was performed one time each in the axial and right angle directions of the main valve and armature for both energized and de-energized conditions. Vibration resistance: No malfunction resulted during a one-sweep test between. and 000 Hz. The test was performed in the axial and right angle directions of the main valve and armature for both energized and de-energized conditions. Manifold pecifications eries V R- ize ( mm ) V R- ize ( mm ) Manifold model VV0 VV0, (P, R) /" Built-in silencer (Option) /" Built-in silencer (Option) Port size Mass (g) Wiring specifications, (A, B) /" (ide, Bottom) /" (ide) /" (ide, Bottom), (PE, X) /" /" Note ) -station manifold Note ) Mass for each wiring part is not included. Note ) The maximum number of solenoids for the unit compatible with the A-Interface is or, depending on the specifications. 0 -station addition 0 0 Type kit: erial transmission Gateway-type (EX00) For I/O (EX0) For I/O (EX00) For Output (EX) F kit: D-sub connector P kit: Flat ribbon cable connector T kit: Terminal block box kit: ead wire M kit: Circular connector Max. Mass number of solenoids (g) Note ) (R) (P)(R) -position dual -port valve Note) (A) (A) (R) N.C. (A) (R) N.O. (A) (R) N.C. (P) (P) (P) (B) (R) N.C. -position dual -port valve Note) (B) (B) (R) N.O. -position dual -port valve Note) (C) (B) Note) Rubber seal only (R) N.O. Flow-rate Characteristics eries V R- ize ( mm ) V R- ize mm ( ) Type of actuation -position -position -position -position -position -position ingle Double Closed center Exhaust center Pressure center Dual -port ingle Double Closed center Exhaust center Pressure center Dual -port eal Metal Rubber Metal Rubber Metal Rubber Metal Rubber Metal Rubber Rubber Metal Rubber Metal Rubber Metal Rubber Metal Rubber Metal Rubber Rubber Flow-rate characteristics, (P A, B),, (A, B EA, EB) C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv Response time (msec) 0 or less or less or less or less or less 0 or less or less 0 or less or less 0 or less 0 or less or less 0 or less or less 0 or less 0 or less 0 or less 0 or less 0 or less 0 or less 0 or less 0 or less Mass (g)

8 eries V R-/V R- Manifold Options Refer to pages through to for details. Blanking plate assembly VV00-A (ize mm) VV00-A (ize mm) Individual UP spacer VV0-P-0 (ize mm) VV0-P-0 (ize mm) Individual EXH spacer VV0-R-0 (ize mm) VV0-R-0 (ize mm) UP block plate VV00-A (ize mm) VV00-A (ize mm) EXH block plate VV00-A (ize mm) VV00-A (ize mm) Direct EXH outlet with built-in silencer [-] Exhaust Interface regulator VV00-ARB- - External pilot specification pecial electrical wiring specifications [-K] Port plug AXT- External pilot port mm and mm sizes mixed D-sub connector 0 0 tation tation tation tation tation tation tation tation Terminal no. O.A O.A O.A O.A O.A O.B O.A O.B O.A O.B O.A O.B COM. Connector terminal no. tandard manifolds are for double wiring, but mixed wiring (single and double wiring) can be specified as an option.

9 PWR COM EX00 series PWR COM series EX00 I / E / MC R kit (erial transmission) For EX00 Gateway-type serial transmission system eries V - Conforms to IO 0- tandard Port olenoid Valve/Plug-in Type eries V R-/V R- IP compliant VV0 (ize mm) kit (erial transmission kit: EX00) M x earth thread C (M) Rc, G (According to IO-), NPTF /" Pilot port x Rc, G (According to IO-), NPTF /" (R) port Rc, G (According to IO-), NPTF /" Pilot exhaust port C (M)... x Rc, G (According to IO-), NPTF /" (n-) x. (P) port n x Rc, G (According to IO-), NPTF /" (A), (B) port D side. tation number (n-) x n U side Indicator light. (-position) (Double dual -port).. (ingle) Manual override I unit x M mounting holes Dimension (mm) n 0 0 Formula: = n +, = n + 0 n: tations (Maximum stations) VV0 (ize mm) kit (erial transmission kit: EX00) M x earth thread Rc, G (According to IO-), NPTF /" Pilot port x Rc, G (According to IO-), NPTF /" (R) port C (M) Rc, G (According to IO-), NPTF /" Pilot exhaust port C (M). x Rc, G (According to IO-), NPTF /" (P) port D side.. (n-) x tation number n U side (n-) x..... n x Rc, G (According to IO-), NPTF /" (A), (B) port Indicator light Manual override (-position) (Double dual -port) (ingle) I unit. x M mounting holes Dimension (mm) n Formula: = n +, = n +. n: tations (Maximum stations)

10 PWR AUX ADDRE ETTING ADDR PWR AUX CEAR IN COM W -ERR -ERR HOD ADDR EX0 ADDRE ETTING ADDR BU PWR BU PWR CEAR IN COM W -ERR -ERR HOD ADDR EX0 I E / / MC eries V R-/V R- R kit (erial transmission) For EX0 Integrated-type (I/O) serial transmission system eries V - VV0 (ize mm) kit (erial transmission kit: EX0) M female input connector M female input connector M male communication connector M x earth thread Rc, G (According to IO-), NPTF /" Pilot port IP compliant x Rc, G (According to IO-), NPTF /" (R) port Rc, G (According to IO-), NPTF /" Pilot exhaust port 0. 0 M male. power connector M female earth x Rc, G (According to IO-), NPTF /" (P) port x M mounting holes. (-position) (Double dual -port).. (ingle). 0 0 D side (n-) x tation number (n-) x Indicator light Manual override..... n x Rc, G (According to IO-), NPTF /" (A), (B) port n U side Input block I unit x M mounting holes Dimension (mm) Formula: = n +, = n + 0 n: tations (Maximum stations) n In case of piece in the input block. The dimension is added by mm at piece addition. VV0 (ize mm) kit (erial transmission kit: EX0) M female input connector M female input connector M male communication connector M x earth thread Rc, G (According to IO-), NPTF /" Pilot port x Rc, G (According to IO-), NPTF /" (R) port Rc, G (According to IO-), NPTF /" Pilot exhaust port M male. power connector M female earth x Rc, G (According to IO-), NPTF /" (P) port D side x M mounting holes. (n-) x tation number n U side Indicator light (n-) x..... n x Rc, G (According to IO-), NPTF /" (A), (B) port Manual override (-position) (Double dual -port) (ingle) Input block I unit. x M mounting holes Dimension (mm) Formula: = n +, = n +. n: tations (Maximum stations) n In case of piece in the input block. The dimension is added by mm at piece addition.

11 I I E / E / / / MC MC R kit (erial transmission) For EX00 Integrated-type (I/O) serial transmission system eries V - Conforms to IO 0- tandard Port olenoid Valve/Plug-in Type eries V R-/V R- IP compliant VV0 (ize mm) kit (erial transmission kit: EX00) M connector type n + n Power connector. (-position) (Double dual -port).. (ingle) 0 0 / inch connector type Communication connector M x earth thread. x Rc, G (According to IO-), NPTF /" (P) port.. 0 M x earth thread. x Rc, G (According to IO-), NPTF /" (P) port Rc, G (According to IO-), NPTF /" Pilot port D side (n-) x (n-) x tation number (n-) x.. Rc, G (According to IO-), NPTF /" Pilot port Communication connector D side n tation number.. n + n (n-) x n U side x Rc, G (According to IO-), NPTF /" (R) port Rc, G (According to IO-), NPTF /" Pilot exhaust port.... Indicator light Manual override.. n x Rc, G (According to IO-), NPTF /" (A), (B) port FE terminal I unit Connector for handheld x M mounting holes Input connector Output connector Dimension (mm) Digital input unit Digital output unit Formula: = n +, = n + n: tations (Maximum stations) n In case of without input/output unit. The dimension is added by mm at piece addition. Indicator light.. x Rc, G (According to IO-), NPTF /" (R) port Rc, G (According to IO-), NPTF /" Pilot exhaust port n x Rc, G (According to IO-), NPTF /" (A), (B) port U side.(-position) (Double dual -port).. (ingle) 0 0 Manual override FE terminal I unit Connector for handheld x M mounting holes Input connector Output connector Dimension (mm) Digital input unit Digital output unit Formula: = n +, = n + n: tations (Maximum stations) n In case of without input/output unit. The dimension is added by mm at piece addition. 0

12 eries V R-/V R- R kit (erial transmission) For EX00 Integrated-type (I/O) serial transmission system eries V - IP compliant VV0 (ize mm) kit (erial transmission kit: EX00) M connector type M x earth thread. x Rc, G (According to IO-), NPTF /" (P) port Communication D side tation connector. n + n Power connector Rc, G (According to IO-), NPTF /" Pilot port (n-) x (n-) x x Rc, G (According to IO-), NPTF /" (R) port Rc, G (According to IO-), NPTF /" Pilot exhaust port. number n U side..... n x Rc, G (According to IO-), NPTF /" (A), (B) port Indicator light Manual override (-position) (Double dual -port) (ingle) 0 0 FE terminal I unit Connector for handheld x M Input connector mounting holes Output connector Dimension (mm) Digital input unit Digital output unit Formula: = n +, = n +. n: tations (Maximum stations) n In case of without input/output unit. The dimension is added by mm at piece addition.. / inch connector type.. 0 M x earth thread. x Rc, G (According to IO-), NPTF /" (P) port Rc, G (According to IO-), NPTF /" Pilot port (n-) x. x Rc, G (According to IO-), NPTF /" (R) port Rc, G (According to IO-), NPTF /" Pilot exhaust port..... n x Rc, G (According to IO-), NPTF /" (A), (B) port Communication connector D side tation.. n + n number n U side Indicator light (n-) x Manual override (-position) (Double dual -port) (ingle) 0 0 FE terminal I unit Connector for handheld x M Input connector Output connector mounting holes Digital input unit Digital output unit Dimension (mm) Formula: = n +, = n +. n: tations (Maximum stations) n In case of without input/output unit. The dimension is added by mm at piece addition..

13 x0 x x0 x ERR. RD D RUN ERR. RD D RUN PW PW B RATE TATION NO. B RATE TATION NO. I / E / R kit (erial transmission: For EX Integrated-type (Output) serial transmission system eries V - Conforms to IO 0- tandard Port olenoid Valve/Plug-in Type eries V R-/V R- IP compliant VV0 (ize mm) kit (erial transmission kit: EX) x G/ Conduit port M x earth thread Rc, G (According to IO-), NPTF /" Pilot port x Rc, G (According to IO-), NPTF /" (R) port Rc, G (According to IO-), NPTF /" Pilot exhaust port x Rc, G (According to IO-), NPTF /" (P) port (n-) x..... n x Rc, G (According to IO-), NPTF /" (A), (B) port D side. 0 tation number n (n-) x U side Indicator light Dimension (mm) n. (-position) (Double dual -port).. (ingle) 0 I unit 0 MODE V (I No.EXD-MJ) Manual override x M mounting holes Formula: = n +, = n + n: tations (Maximum stations) VV0 (ize mm) kit (erial transmission kit: EX) x G/ Conduit port M x earth thread Rc, G (According to IO-), NPTF /" Pilot port x Rc, G (According to IO-), NPTF /" (R) port Rc, G (According to IO-), NPTF /" Pilot exhaust port x Rc, G (According to IO-), NPTF /" (P) port D side. 0 (n-) x (n-) x. tation number n U side.. Indicator light... n x Rc, G (According to IO-), NPTF /" (A), (B) port Manual override Dimension (mm) n (-position). (Double dual -port) (ingle). 0 I unit 0. MODE V (I No.EXD-MJ) x M mounting holes Formula: = n +, = n +. n: tations (Maximum stations)

14 F eries V R- kit (D-sub connector) IP0 compliant Using our D-sub connector greatly reduces labor, while it also minimizes wiring and saves space. We use a D-sub connector (P) that conforms to MI standards and is therefore widely compatible with many standard commercial models. Top or side entry for the connector can be changed freely, allowing for changes even after mounting, to meet any changing needs for space. Electrical Wiring pecifications D-sub connector 0 0 tation tation tation tation tation tation tation tation tation tation 0 tation tation As the standard electrical wiring specifications, double wiring (connected to O. A and O. B) is adopted for the internal wiring of each station for stations or less, regardless of valve and option types. Mixed single and double wiring are available as an option. Refer to the below special wiring specifications (option). Connector terminal no. 0 0 ead wire colors for D-sub connector assembly 0 (AXT00-D- 00 ) Terminal ead wire Dot no. color marking O.A O.B O.A O.B O.A O.B O.A O.B O.A O.B O.A O.B Yellow Brown Pink Blue Orange Purple Yellow Gray Pink Orange O.A Blue O.B 0 O.A O.B Purple Brown O.A Gray O.B Pink O.A O.B O.A O.B O.A O.B COM. 0 Gray Yellow Orange pecial Wiring pecifications (Option) 00 Mixed single and double wiring are available as an option. The maximum number of manifold stations is determined by the number of solenoids. Count one point for a single solenoid type and two points for a double solenoid type. The total number of solenoids (points) must not exceed. Cable Assembly AXT00-D D-sub connector cable assembly can be ordered with manifolds. Refer to How to Order Manifold. (.) D-sub connector cable assembly Cable length (). m m m 0 MC.0 Assembly part no. AXT00-D-0 AXT00-D-00 AXT00-D-00 Cable 0. mm x cores O.D. ø. Approx. ø0 eal (ength) Molded cover x M. x 0. Connector DB-F-N made by Japan Aviation Electronics Industry, td. ocket side Terminal no. Note Cable 0. mm x cores When using a standard commercial connector, use a type P female connector conforming to MI-C-0. Cannot be used for transfer wiring. engths other than the above is also available. Please contact MC for details. Electrical characteristics Item Property Conductor resistance Ω/km, 0 C Voltage limit V, minute, AC Insulation resistance MΩ/km, 0 C or less 000 or more Note) The minimum bending radius of the D-sub connector cables is 0 mm. ead wire colors for D-sub connector cable assembly terminal numbers Terminal no. 0 0 ead wire color Brown Orange Yellow Pink Blue Purple Gray Yellow Orange Yellow Pink Blue Purple Gray Orange Brown Pink Gray Dot marking Connector Manufacturers Example Fujitsu, td. Japan Aviation Electronics Industry, td. J..T. Mfg. Co., td. Hirose Electric Co., td. COM

15 MC F eries V R- kit (D-sub connector) Conforms to IO 0- tandard Port olenoid Valve/Plug-in Type IP0 compliant eries V R-/V R- VV0 (ize mm) M x earth thread R0 (Min. bending radius) Rc, G (According to IO-), NPTF /" Pilot port x Rc, G (According to IO-), NPTF /" (R) port Rc, G (According to IO-), NPTF /" Pilot exhaust port 0 0 D-sub connector cable assembly (P) AXT00-D-0:. m AXT00-D-00:.0 m AXT00-D-00:.0 m x Rc, G (According to IO-), NPTF /" (P) port Release for switching connector direction. (-position) (Double dual -port).. (ingle). D side / / (n-) x tation number (n-) x / /.. n U side. Indicator light.. Manual override n x Rc, G (According to IO-), NPTF /" (A), (B) port x M mounting holes Applicable connector: D-sub connector (P) (Conforms to MI-C-0) Dimension (mm) n Formula: = n +, = n +. n: tations (Maximum stations) VV0 (ize mm) R0 (Min. bending radius) 0 0 D-sub connector cable assembly (P) AXT00-D-0:. m AXT00-D-00:.0 m AXT00-D-00:.0 m M x earth thread x Rc, G (According to IO-), NPTF /" (P) port Release for switching connector direction Rc, G (According to IO-), NPTF /" Pilot port D side (n-) x (n-) x. tation number n U side x Rc, G (According to IO-), NPTF /" (R) port Rc, G (According to IO-), NPTF /" Pilot exhaust port.. (-position) (Double dual -port) (ingle)... n x Rc, G (According to IO-), NPTF /" (A), (B) port Indicator light Manual override. x M mounting holes Applicable connector: D-sub connector (P) (Conforms to MI-C-0) Dimension (mm) n Formula: = n +, = n + n: tations (Maximum stations)

16 P eries V R- kit (Flat ribbon cable) IP0 compliant Using our flat ribbon cable greatly reduces labor, while it also minimizes wiring and saves space. We use flat ribbon cables whose connectors (P) conform to MI standards, and are therefore widely compatible with many standard commercial models. Top or side entry for the connector can be changed freely, allowing for changes even after mounting, to meet any changing needs for space. Electrical Wiring pecifications Cable Assembly Flat ribbon cable connector 0 0 Connector terminal number Double wiring (connected to O. A and O. B) is adopted for the internal wiring of each station, regardless of valve and option types. Mixed single and double wiring are available as an option. Refer to the below special wiring specifications (option). Triangle mark indicator position AXT00-FC- Type P flat ribbon cable connector assembly can be ordered with manifolds. Refer to How to Order Manifold.. (P) Terminal no. AWG tation tation tation tation tation tation tation tation tation tation 0 tation tation <P> Terminal no. O.A O.B O.A O.B O.A O.B O.A O.B O.A O.B 0 O.A O.B O.A O.B O.A O.B O.A O.B O.A O.B 0 O.A O.B O.A O.B COM. COM. COM 0 0 (.) Flat ribbon cable connector assembly Cable Assembly part no. length () P. m AXT00-FC- m AXT00-FC- m AXT00-FC- When using a standard commercial connector, use a type P connector conforming to MI-C-0 with strain relief. Cannot be used for transfer wiring. engths other than the above is also available. Please contact MC for details. Connector Manufacturers Example Hirose Electric Co., td. umitomo M imited Fujitsu, td. Japan Aviation Electronics Industry, td. J..T. Mfg. Co., td. Oki Electric Cable Co., td. pecial Wiring pecifications (Option) COM Mixed single and double wiring are available as an option. The maximum number of manifold stations is determined by the number of solenoids. Count one point for a single solenoid type and two points for a double solenoid type. The total number of solenoids (points) must not exceed.

17 I / E / MC P eries V R- kit (Flat ribbon cable) Conforms to IO 0- tandard Port olenoid Valve/Plug-in Type IP0 compliant eries V R-/V R- VV0 (ize mm) Flat ribbon cable assembly (P) AXT00-FC-:. m AXT00-FC-:.0 m AXT00-FC-:.0 m M x earth thread Rc, G (According to IO-), NPTF /" Pilot port x Rc, G (According to IO-), NPTF /" (R) port Rc, G (According to IO-), NPTF /" Pilot exhaust port x Rc, G (According to IO-), NPTF /" (P) port (n-) x.. n x Rc, G (According to IO-), NPTF /", /" (A), (B) port Release for switching connector direction tation D side number n (n-) x U side Indicator light Manual override. (-position) (Double dual -port).. (ingle). x M mounting holes Applicable connector: Flat ribbon cable connector (P) (Conforms to MI-C-0) Dimension (mm) n Formula: = n +, = n +. n: tations (Maximum stations) VV0 (ize mm) Flat ribbon cable assembly (P) AXT00-FC-:. m AXT00-FC-:.0 m AXT00-FC-:.0 m Rc, G (According to IO-), NPTF /" Pilot port x Rc, G (According to IO-), NPTF /" (R) port Rc, G (According to IO-), NPTF /" Pilot exhaust port 0 0 M x earth thread Release for switching connector direction x Rc, G (According to IO-), NPTF /" (P) port D side (n-) x (n-) x. tation number n U side..... n x Rc, G (According to IO-), NPTF /" (A), (B) port Indicator light Manual override (-position) (Double dual -port) (ingle). x M mounting holes Applicable connector: Flat ribbon cable connector (P) (Conforms to MI-C-0) Dimension (mm) n Formula: = n +, = n + n: tations (Maximum stations)

18 eries V - T R kit (Terminal block box) IP compliant This kit has a small terminal block inside a junction box. The electrical entry port of a G / permits connection of conduit fittings. Terminal Block Connection tep. Removing the terminal block cover oosen the mounting screws (M) and remove the terminal block cover. Mounting screw (M) Terminal block cover tep. The diagram below shows the terminal block wiring. All stations are provided with double wiring regardless of the valves which are mounted. Connect each wire to the power supply side, according to the markings provided inside the terminal block. M screw Gasket Electrical entry x G / mm tep. Mounting the terminal block cover ecurely tighten the screws to the torque shown below, after confirming that the gasket is installed correctly. Proper tightening torque (N m) 0. to. Applicable crimped terminal:.-,.y-,.y-n,.y-. Name plate: VVQ000-N-T Drip-proof plug assembly (for G /): AXT00-B0A Electrical Wiring pecifications B B B B B B B B B 0B A A A A A A A A A 0A COM A A A A A A A A A 0A COM Double wiring (connected to O. A and O. B) is adopted for the internal wiring of each station, regardless of the type of valve or options. Mixed single and double wiring are available as an option. B B B B B B B B B 0B tation tation tation tation tation tation tation tation tation tation 0 tandard wiring Terminal no. O.A O.B O.A O.B O.A O.B O.A O.B O.A O.B O.A O.B O.A O.B O.A O.B O.A O.B O.A O.B A B A B A B A B A B A B A B A B A B 0A 0B COM. mm pecial Wiring pecifications (Option) Mixed single and double wiring are available as an option. The maximum number of manifold stations is determined by the number of solenoids. Count one point for a single solenoid type and two points for a double solenoid type. The total number of solenoids (points) must not exceed 0.. How to Order Indicate option symbol -K in the manifold part number and be sure to specify station positions for single or double wiring on the manifold specification sheet.. Wiring specifications Connector terminal numbers are connected from solenoid station on the A side in the order indicated by the arrows without skipping any terminal numbers. B B B B B B B B B 0B A A A A A A A A A 0A COM A A A A A A A A A 0A COM B B B B B B B B B 0B

19 I / E / T eries V R- Conforms to IO 0- tandard Port olenoid Valve/Plug-in Type kit (Terminal block box) IP compliant eries V R-/V R- VV0 (ize mm) x G/ Conduit port Rc, G (According to IO-), NPTF /" Pilot port x Rc, G (According to IO-), NPTF /" (R) port Rc, G (According to IO-), NPTF /" Pilot exhaust port M x earth thread x Rc, G (According to IO-), NPTF /" (P) port (n-) x. n x Rc, G (According to IO-), NPTF /". (A), (B) port. D side tation number n (n-) x U side Indicator light Dimension (mm) n... (-position) (Double dual -port).. (ingle) Manual override x M mounting holes Formula: = n +, = n + 0. n: tations (Maximum 0 stations) VV0 (ize mm) Rc, G (According to IO-), NPTF /" Pilot port x G/ Conduit port x Rc, G (According to IO-), NPTF /" (R) port Rc, G (According to IO-), NPTF /" Pilot exhaust port.. 0. M x earth thread x Rc, G (According to IO-), NPTF /" (P) port (n-) x n x Rc, G (According to IO-), NPTF /" (A), (B) port D side tation number n U side (n-) x Indicator light Manual override (-position) (Double dual -port) (ingle) 0. x M mounting holes Dimension (mm) n Formula: = n +, = n + n: tations (Maximum stations)

20 eries V R- kit (ead wire) IP compliant Direct electrical entry type IP enclosure is available with use of cables with sheath and waterproof connectors. Electrical Wiring pecifications ead wire ead wire 0. mm x cores heath Color: As the standard electrical wiring specifications, double wiring (connected to O. A and O. B) is adopted for the internal wiring of each station for stations or less, regardless of valve and option types. Mixed single and double wiring are available as an option. Refer to the below special wiring specifications (option). Electrical characteristics Item Property Conductor resistance Ω/km, 0 C Voltage limit V, minute, AC Insulation resistance MΩ/km, 0 C or less 000 or more Note) Cannot be used for transfer wiring. The minimum bending radius of the cable is 0 mm. tation tation tation tation tation tation tation tation tation tation 0 tation tation O.A O.B O.A O.B O.A O.B O.A O.B O.A O.B O.A O.B O.A O.B O.A O.B O.A O.B O.A O.B O.A O.B O.A O.B COM. Terminal no. ead wire color Dot marking Yellow Brown Pink Blue Orange Purple Yellow Gray Pink Orange Blue 0 Purple Brown Gray Pink 0 Gray Yellow Orange pecial Wiring pecifications (Option) Mixed single and double wiring are available as an option. The maximum number of manifold stations is determined by the number of solenoids. Count one point for a single solenoid type and two points for a double solenoid type. The total number of solenoids (points) must not exceed.

21 I / E / eries V R- Conforms to IO 0- tandard Port olenoid Valve/Plug-in Type kit (ead wire) IP compliant eries V R-/V R- VV0 (ize mm) Rc, G (According to IO-), NPTF /" Pilot port x Rc, G (According to IO-), NPTF /" (R) port Rc, G (According to IO-), NPTF /" Pilot exhaust port 0 0 M x earth thread x Rc, G (According to IO-), NPTF /" (P) port. (n-) x.... n x Rc, G (According to IO-), NPTF /" (A), (B) port D side tation number (n-) x n U side Indicator light Manual override. (-position) (Double dual -port).. (ingle) MC x M mounting holes Dimension (mm) n Formula: = n +, = n +. n: tations (Maximum stations) VV0 (ize mm) Rc, G (According to IO-), NPTF /" Pilot port M x earth thread 0 0 x Rc, G (According to IO-), NPTF /" (P) port (n-) x x Rc, G (According to IO-), NPTF /" (R) port Rc, G (According to IO-), NPTF /" Pilot exhaust port n x Rc, G (According to IO-), NPTF /" (A), (B) port D side n U side tation number Indicator light (n-) x Manual override (Double dual -port) (ingle). (-position) x M mounting holes Dimension (mm) n Formula: = n +, = n + n: tations (Maximum stations)

22 M eries V R- kit (Circular connector) IP compliant Use of circular connectors helps streamline wiring procedure to save labor. IP enclosure is available with use of waterproof circular connectors. Electrical Wiring pecifications Circular connector! q!! e! r! t!0 y o i u tation tation tation tation tation tation tation tation tation tation 0 tation tation Double wiring (connected to O.A and O.B) is adopted for the internal wiring of each station, regardless of valve and option types. Mixed single and double wiring are available as an option. Refer to the below special wiring specifications (option). Terminal no. O.A O.B O.A O.B O.A O.B O.A O.B O.A O.B 0 O.A O.B O.A O.B O.A O.B O.A O.B O.A O.B 0 O.A O.B O.A O.B COM. COM. ead wire colors for circular connector cable assembly 0 (AXT00-MC- 00 ) ead wire color Brown Orange Yellow Pink Blue Purple Gray Yellow Orange Yellow Pink Blue Purple Gray Orange Brown Pink Gray Dot marking pecial Wiring pecifications (Option) Mixed single and double wiring are available as an option. The maximum number of manifold stations is determined by the number of solenoids. Count one point for a single solenoid type and two points for a double solenoid type. The total number of solenoids (points) must not exceed. 00 Cable Assembly AXT00-MC Type P circular connector cable assembly can be ordered with manifolds. Refer to How to Order Manifold. 0 Circular connector cable assembly Cable length (). m m m 0 ø0 0 0 Cable 0. mm x cores O.D. ø. Approx. 0 eal (ength) Plug Terminal no. M female thread Assembly part no. P AXT00-MC-0 AXT00-MC-00 AXT00-MC-00 Cannot be used for transfer wiring. engths other than the above is also available. Please contact MC for details. ead wire colors for circular connector cable assembly terminal numbers Terminal ead no. wire color 0 0 Brown Orange Yellow Pink Blue Purple Gray Yellow Orange Yellow Pink Blue Purple Gray Orange Brown Pink Gray Dot marking Electrical characteristics Item Property Conductor resistance or less Ω/km, 0 C Voltage limit 000 V, minute, AC Insulation resistance or more MΩ/km, 0 C Note) The minimum bending radius of the circular connector cable is 0 mm.

23 / MC M eries V R- VV0 (ize mm) M x earth thread. (-position) (Double dual -port). 0.. (ingle) x Rc, G (According to IO-), NPTF /" (P) port Circular connector cable assembly AXT00-MC-0:. m AXT00-MC-00: m AXT00-MC-00: m Conforms to IO 0- tandard Port olenoid Valve/Plug-in Type kit (Circular connector) IP compliant x Rc, G (According to IO-), NPTF /" (R) port Rc, G (According to IO-), NPTF /" Pilot port D side / / (n-) x (n-) x tation number /. n Rc, G (According to IO-), NPTF /" Pilot exhaust port.. U side Indicator light Manual override eries V R-/V R-.. n x Rc, G (According to IO-), NPTF /" (A), (B) port x M mounting holes Dimension (mm) n Formula: = n +, = n +. n: tations (Maximum stations) VV0 (ize mm) M x earth thread x Rc, G (According to IO-), NPTF /" (R) port Rc, G (According to IO-), NPTF /" Pilot port Rc, G (According to IO-), NPTF /" Pilot exhaust port 0 0 x Rc, G (According to IO-), NPTF /" (P) port (n-) x n x Rc, G (According to IO-), NPTF /" (A), (B) port D side n U side tation number Indicator light (n-) x Manual override Circular connector cable assembly AXT00-MC-0 :. m AXT00-MC-00 :.0 m AXT00-MC-00 :.0 m (Double dual -port) (ingle).. (-position) x M mounting holes Dimension (mm) n Formula: = n +, = n + n: tations (Maximum stations)

24 eries V R-/V R- Manifold Options Blanking plate assembly VV00-A (ize mm) VV00-A (ize mm) 0. By attaching this on a manifold block, it is possible to prepare for removing a valve for maintenance reasons or planning to mount a spare valve, etc. (A) (B) ize mm. 0 (R) (P) (R) Circuit diagram ize mm Individual UP spacer (F) VV0-P-0 (T) (ize mm) (F) VV0-P-0 (ize mm) (T) By mounting individual UP spacers on a manifold block, it is possible to provide individual UP ports for each valve... /" (P') (P) (A) (B). ize mm (R) (R) /" Circuit diagram.. ize mm Individual EXH spacer (F) VV0-R-0 (T) (ize mm) (F) VV0-R-0 (T) (ize mm) By mounting individual EXH spacers on a manifold block, it is possible to provide individual EXH ports for each valve. ((R), (R) common EXH type) (R') (P) (A) (B). ize mm.. /" (R) (R) /" Circuit diagram.. ize mm

25 Conforms to IO 0- tandard Port olenoid Valve/Plug-in Type eries V R-/V R- UP block plate VV00-A (ize mm) VV00-A (ize mm) When different pressures are supplied to a manifold, a UP block plate is used to block the stations under different pressures ize mm ize mm EXH block plate VV00-A (ize mm) VV00-A (ize mm).... This is used to divide the exhaust passage when the exhaust from a valve interferes with the valve of other stations.. ize mm ize mm Direct EXH outlet with built-in silencer [-] This is a type with an exhaust port atop the manifold end plate. The built-in silencer exhibits an excellent noise suppression effect. (Noise reduction: 0 db) When ordering this option incorporated with a manifold, suffix - to the end of the manifold part number. Exhaust Built-in ilencer Element Replacement Caution A filter element on both sides is built into the manifold base end plate. When the element becomes dirty and clogged, this will cause trouble such as a drop in the cylinder speed, etc. Therefore, replace the element regularly. Element Part No. Type Direct EXH outlet with built-in silencer This is for manifold set. Element part no. ize mm (VV0) ize mm (VV0) VV0-E VV0-E To replace an element, remove the cover on the top side of the end plate and remove the old element with a flat head screwdriver, etc. ize mm VV0-E ize mm VV0-E

26 eries V R-/V R- Manifold Options Interface regulator (P, A, B port regulation) pecifications Interface regulator model Regulating port Applicable solenoid valve Max. operating pressure (MPa) et pressure range (MPa) Fluid Ambient and fluid temperature ( C) Pressure gauge port size Mass (kg) Effective area at supply side (mm ) P = 0. MPa, P = 0. MPa Effective area at exhaust side (mm ) P = 0. MPa (P) (A) (P) (B) (A) (R) (B) (R) Note ) et the pressure within operating pressure range of solenoid valve. Note ) When using A port regulation and B port regulation in a closed center, please contact MC because there will be a problem in its operation. Note ) IP enclosure is not available with interface regulator. A VV00-ARB- - B P V R to 0. Air to 0 M x A, B How to Order Applicable solenoid valve model V R- (ize mm) Interface regulator model VV00-ARB-A- VV00-ARB-B- VV00-ARB-P- VV00-ARB-AB- Regulating port A B P A, B Unit: mm MC MC 0 / A VV00-ARB- B- P VV00-ARB-AB- Regulating port: A, B Regulating port: A Regulating port: B Regulating port: P

27 Conforms to IO 0- tandard Port olenoid Valve/Plug-in Type eries V R-/V R- Manifold Options External pilot specification Either internal pilot or external pilot can be selected when ordering a manifold (internal pilot is standard). The arrow on the silencer cover points to I when using the internal pilot and E when using the external pilot. It can be changed later by changing the mounting orientation of the silencer cover. <How to change the pilot type> ) Remove the silencer cover. ) Turn the silencer cover 0 and mount it to the end plate. At the same time, mount the built-in rivet as the same place with the arrow on silencer cover. Note ) Do not let the gasket get caught when mounting the silencer cover. Note ) For internal pilot specification, it is not necessary to mount a plug to the external pilot port. Arrow External pilot port /" female thread (D side only) ilencer cover Mounting screw VV0 M Tightening torque. to. N m VV0 M Tightening torque to. N m Internal pilot External pilot D-side end plate Rivet Port plug Part no. Thread size, type AXT-0 For Rc /" AXT-0 For Rc /" AXT-0 For Rc /" AXT-0 For Rc /" AXT-0T For NPTF /" AXT-0T For NPTF /" AXT-0T For NPTF /" AXT-0T For NPTF /" AXT-0F# For G /" AXT-0F# For G /" AXT-0F# For G /" AXT-0F# For G /" This is used to plug the cylinder ports when using as a -port valve, etc.

28 eries V R-/V R- Manifold Options mm and mm sizes mixed An mm valve can be mounted on a mm manifold. How to Order Manifold VV0 0 0 FD0 W M tations station stations ize mm Cylinder port size 0 0B ide ported /" Bottom ported /" Thread type Nil Rc T NPTF F G Note) Note) Conforms to IO- Wiring specifications Other option CE compliant Nil Q CE compliant mm and mm sizes mixed ize mm Cylinder port size 0 0 0B ide ported /" ide ported /" Bottom ported /" How to Order Manifold Block Assembly How to Order Manifold V R FG V Z eal type R Rubber Metal Number of solenoids D Double Note) ingle Nil Z ize ize mm ize mm Type of actuation FG -position FHG -position closed center FJG -position exhaust center FIG -position pressure center FDAG Note) -position dual -port (N.C. + N.C.) FDBG Note) -position dual -port (N.O. + N.O.) FDCG Note) -position dual -port (N.C. + N.O.) Note) Rubber seal only Note) ingle solenoid is available with -position only. Rated voltage VDC VDC Individual pilot exhaust ight/surge voltage suppressor Note) With indicator light / surge voltage suppressor Note) Not applicable to the kit. Nil B Internal/External pilot Nil Internal pilot R External pilot Manual override Push type ocking type (Tool required) CE compliant Nil Q CE compliant Example D side U side VV0-00-FD0-W-M VR--FG--VZ VR--FG--VZ ingle solenoid valve VR--FG--VZ Manifold base ( stations) VV0-00-FD0-W-M ingle solenoid valve VR--FG--VZ set (F kit manifold with sizes mixed specification) sets (ingle solenoid part no.) sets (ingle solenoid part no.) The symbol indicates built-in. Put the symbol at the beginning of part numbers to have solenoid valves attached. Valve arrangement is counted from the D side. When ordering, specify the part numbers in order from the first station on the D side. In the case of complex arrangement, specify them by means of the manifold specification sheet.

29 MC Conforms to IO 0- tandard Port olenoid Valve/Plug-in Type eries V R-/V R- Dimensions (F kit) VV0 - -FD-W-M x /" (R) port x /" Pilot port = x n + x n + = + n: Piece of ize mm n: Piece of ize mm (0) / /..... (.).. 0. x /" (P) port n x /", /" (A), (B) port (ize mm) n x /" (A), (B) port (ize mm) D side tation number n U side (). ize ( mm pitch). ize ( mm pitch). (-position) (Double dual -port).. (ingle) (ingle) (Double dual -port) (-position)

30 eries V R- Construction Construction Metal seal Rubber seal V--FG-- VR--FG-- e r e r t q w t q w V--FG-D- VR--FG-D- e r e r t q w t q w V-- FHG FIG FJG -D- e r VR-- FHG FIG FJG -D- e r t q w t q w VR-- FDAG FDBG FDCG e r -D- t q w Replacement Parts No. Description V--FG-- V--FG-D- V-- FHG FIG FJG -D- VR--FG-- VR--FG-D- VR-- FHG FIG FJG -D- VR-- FDAG FDBG FDCG -D- Gasket Hexagon bolt ight cover O-ring O-ring EV00--H AXT-- (M x 0, with washer, nickel plated) EV00--. x. OR H

31 eries V R- Construction Construction Metal seal Rubber seal V--FG-- VR--FG-- e r e r t q w t q w V--FG-D- VR--FG-D- e r e r t q w t q w V-- FHG FIG FJG e r -D- VR-- FHG FIG FJG e r -D- t q w VR-- FDAG FDBG FDCG e r t q w -D- t q w Replacement Parts No. Description V--FG-- V--FG-D- V-- FHG FIG FJG -D- VR--FG-- VR--FG-D- VR-- FHG FIG FJG -D- VR-- FDAG FDBG FDCG -D- Gasket Hexagon bolt ight cover O-ring O-ring EV00--H AXT-- (M x 0, with washer, nickel plated) EV00--. x. OR H 0

32 Exploded View of Manifold Housing assembly and I unit D-side end plate assembly Manifold block assembly U-side end plate assembly kit EX00 EX0 EX00 r q e w i u EX P kit F kit!! T kit!! kit! M kit! The exploded view indicates VV0.

33 Conforms to IO 0- tandard Port olenoid Valve/Plug-in Type eries V R-/V R- Manifold Assembly Part No. Housing Assembly, I Unit, etc. No. Description I unit I unit Input block End plate assembly Valve plate I unit Digital input unit Digital output unit Analog input unit End plate I unit 0 Plate assembly D-sub connector housing assembly Flat ribbon cable housing assembly Terminal block box housing assembly Terminal block box assembly Terminal block plate assembly ead wire housing assembly Circular connector housing assembly Part no. EX00-Q00 EX00-Q00-X EX00-Q0 EX00-Q0-X EX0-DN EX0-PR EX0-MJ EX0-A EX0-A EX0-A EX0-A EX0-CAA EX0-CN EX0-EN EX0-IE EX0-IE EX0-IE EX0-EA EX00-ZMV EX00-DN EX00-DN EX00-MJ EX00-MJ EX00-PR EX00-PR EX00-DXPB EX00-DXNB EX00-DXPC EX00-DXNC EX00-DXPC EX00-DXNC EX00-DXPD EX00-DXND EX00-DYPB EX00-DYNB EX00-AXA EX00-ED EX00-ED EXD-MJ VVQC000-A- VVQC000-P- VVQC000-F- VVQC000-T0- VVQC000-0A-D VVQC000-A- VVQC VVQC VVQC VVQC000-M- Note +COM., DeviceNet, PROFIBU DP, CC-ink, EtherNet/IP +COM., Remote I/O COM., DeviceNet, PROFIBU DP, CC-ink, EtherNet/IP COM., Remote I/O DeviceNet ( COM.) PROFIBU DP ( COM.) CC-ink (+COM.) A-Interface ( in/ out, slave modes, power supply systems, COM.) A-Interface ( in/ out, slave modes, power supply systems, COM.) A-Interface ( in/ out, slave modes, power supply systems, COM.) A-Interface ( in/ out, slave modes, power supply systems, COM.) CANopen ( COM.) ControlNet ( COM.) EtherNet/IP ( COM.) M, inputs M, inputs M, inputs DeviceNet ( COM.) DeviceNet (+COM.) CC-ink ( COM.) CC-ink (+COM.) PROFIBU DP ( COM.) PROFIBU DP (+COM.) PNP, M, inputs NPN, M, inputs PNP, M, inputs NPN, M, inputs PNP, M, inputs, with open detection function NPN, M, inputs, with open detection function PNP, M, inputs NPN, M, inputs PNP, M, outputs NPN, M, outputs -channel input M connector / inch connector CC-ink (+COM.), outputs F kit, pins P kit, pins T kit T kit T kit kit with 0. m lead wire kit with. m lead wire kit with.0 m lead wire M kit, pins

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000

More information

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),

More information

VQ1000. How to Order Manifold. Kit type

VQ1000. How to Order Manifold. Kit type - - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold

More information

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications Series -SQ00 Port Solenoid Valve Plug-in Unit [Option] How to Order Manifold Electrical entry F kit D-sub connector kit P kit SSQ 08 FD Kit type Flat ribbon cable connector kit J kit Flat ribbon cable

More information

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000 D-sub Connector J Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000//000 Number of connectors: pins MIL-C-08 Conforming to JIS-X-0 --6 For details

More information

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector

More information

Terminal Block Box (Spring Type) SY3000/5000/7000 Series

Terminal Block Box (Spring Type) SY3000/5000/7000 Series INFORMATION 5 ort olenoid alve Terminal lock ox (pring Type) Y3000/5000/7000 eries Compact RoH Height 6.7 mm shorter (Approx. 9% reduction) Installation area of the terminal block box Reduced by approx.

More information

Applicable bore size. CC-Link. EtherNet/IP. Decentralized Serial Wiring. EtherCAT I/O. Serial unit: EX600 IP67 compliant. Serial unit: EX500

Applicable bore size. CC-Link. EtherNet/IP. Decentralized Serial Wiring. EtherCAT I/O. Serial unit: EX600 IP67 compliant. Serial unit: EX500 5 Port Solenoid Valve Series C000 Metal Seal Rubber Seal Compact and large flow Type (Series) Manifold pitch (mm) C000 5 6. 0.7.7 7. 0..0 to ø Note) Flow characteristics: position single, / 5/ (/ R/R)

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

F Kit. D-sub. connector. D-sub. connector) Compatible network DeviceNet PROFIBUS DP. CC-Link. Compatible D-sub connector. Output

F Kit. D-sub. connector. D-sub. connector) Compatible network DeviceNet PROFIBUS DP. CC-Link. Compatible D-sub connector. Output Series VQC000 ase Mounted: Variations 5 Port Solenoid Valve Series VQC000 Sonic Conductance C[dm /(s bar)] Values: CYL EXH / 5/ Single/Double position (Closed center) pplicable bore size Compatible network

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Series VQ Rubber Seal Space-saving profile Clean space saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer Base Mounted Metal Seal/Rubber Seal VQ Built-in silencer, direct exhaust Space-saving profile All pilot valves are compactly mounted on one side. The space-saving design of mounting all fittings on one

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Base Mounted Plug-in Unit

Base Mounted Plug-in Unit For details about certified products conforming to international standards, visit us at www.smcworld.com. Plug-in Unit SI unit COM N VVQC VVQC C C C6 M CM 6 B B B6 B M Series VQC Manifold model Plug-in

More information

New Concept Connector Type Manifold

New Concept Connector Type Manifold New Concept Connector Type Manifold Series /000/3000/000 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration.

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Rubber Seal Series VQ Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

Manifold Specifications

Manifold Specifications Specifications Specifications Base mounted VVFR-01 VVFR- VVFR-0 Wiring With terminal block With multi-connector With D-sub connector Grommet terminal DIN terminal Grommet Grommet terminal Conduit terminal

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Port Solenoid Valve Metal Seal Rubber Seal Series Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series

More information

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Body Ported Base Mounted Series S000 S000 S000 S000 S000 S4000 S5000 Sonic conductance C [dm /s bar)] 4/ 5/(A/B R/R) Single Double.8.4

More information

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is. Port Solenoid Valve Series VQ 00 Unprecedented high speed, stable response, and extra-long service life. ON:.ms, OFF: ms, Dispension accuracy ±ms (With indicator light and surge voltage suppressor; supply

More information

Gateway Type Serial Transmission System

Gateway Type Serial Transmission System P99-EX-B Gateway Type Serial Transmission System P Maximum 8 point control (64 inputs/64 outputs) P Flexibility of manifold valve installation improved with 4 branch wiring Flexible installation and removal

More information

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000) 5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

Flow characteristics Max. (1) b Standard Specifications. P Manual override.

Flow characteristics Max. (1) b Standard Specifications. P Manual override. Port Direct Operated Solenoid Valve Series 0 Metal Seal Model Number of positions (Single) (Double) ( position) JIS Symbol Model Port size Rc (Nominal size) 0-0 8 ( A) 0- ( 8A) 0-0 8 (0A) 0-0 8 ( A) 0-

More information

Fieldbus System (Output device for driving 5 port solenoid valves)

Fieldbus System (Output device for driving 5 port solenoid valves) Fieldbus System (Output device for driving port solenoid valves) New Compact 8mm (ctual size) Space-saving Installation IP67 RoHS EtherNet/IP added! For units with D-sub connector, and when connected to

More information

Manifold Specifications Stacking Type

Manifold Specifications Stacking Type Specifications Stacking Type Keeps environmental air clean from pilot exhaust Use of the VV5FS- manifold can exhaust intensively the pilot exhaust gas to the base side, and can prevent environmental aggravation

More information

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

SMC guide to ATEX compliant products

SMC guide to ATEX compliant products SMC guide to ATEX compliant products P-E13-23A A ATEX Directive Directive 94/9/EC Equipment and Protective Systems intended for use in potentially Explosive Atmospheres Outline of ATEX directive Since

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring Type4 SY000/000 ase Mounted Monifold Stacking Type/DIN ail Mounted Individual Wiring How to Order Manifold SSY 4 0 U C6 How to Order Valve Manifold ssembly Ordering example SY000 SY000 Valve stations 02

More information

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection Rubber Seal Port Solenoid Valve Series SJ000/000 Cassette Type Manifold 0 mm 7. mm (SJ000) 0 mm (SJ000) Non plug-in type Individual wiring manifold SJ000 SJ000 Can be mounted together. Connecter connection

More information

CAT.E152-5 Port Solenoid Valve/Body Ported Cassette Type Manifold. Series SZ3000

CAT.E152-5 Port Solenoid Valve/Body Ported Cassette Type Manifold. Series SZ3000 CAT.E- Port Solenoid Valve/Body Ported Cassette Type Manifold Series SZ000 The plug-in cassette system makes valve replacement easy. A plug-in manifold has been realized having a manifold height of.mm

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model 2 position 3 position

More information

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

More information

How to Order Manifold. Kit type L8 B4 B6 B8 LM

How to Order Manifold. Kit type L8 B4 B6 B8 LM 0 Stations station VVQ Series VQ000 The maximum and minimum number of are varied depending on. (Refer to the table below.) Series VQ000 ase Mounted Plug-in Unit Manifold Plug-in unit 08 C Cylinder port

More information

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal Port Solenoid Valve Cassette Type Manifold Rubber Seal 7.mm (SJ000) SJ000 SJ000 Can be mounted together. 0mm (SJ000) Connector connection New New cable type manifold is added! New Additional options are

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR2 JIS Symbol type

More information

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I ISO Standard Solenoid Valve Series VQ7-6/7-8 (Size ) (Size ) Conforms to ISO Standard /I.0- Ideal for driving cylinders up to Large flow capacity ø00 (VQ7-6, Size ) ø60 (VQ7-8, Size ) Nl/min VQ7-6: 668.

More information

Series SYA3000/5000/7000

Series SYA3000/5000/7000 1 Port Air Operated Valve Series SYA000/000/7000 Body ported Base mounted Base mounted How to Order A, B port size Thread type Thread piping (Inch size) Nil Rc Symbol Port size Applicable series Symbol

More information

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot 3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

Electro-Pneumatic Regulator Electronic Vacuum Regulator

Electro-Pneumatic Regulator Electronic Vacuum Regulator Electro-Pneumatic Regulator Electronic Vacuum Regulator New Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to Series ITV//! Reduced wiring

More information

ISO Standard Solenoid Valve/SIZEq Rubber Seal Series VP7 6

ISO Standard Solenoid Valve/SIZEq Rubber Seal Series VP7 6 ISO Standard Solenoid Valve/SIZq Rubber Seal Series VP7 6 VP7 6 FPG D VP7 6 FG D position position Single solenoid (FG-S) Double solenoids (FG-D) Reverse pressure (YZ-S) Reverse pressure (YZ-D) Closed

More information

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve CT.E- ase Mounted Type Series VQ Port Metal Seal/Rubber Seal Solenoid Valve dvanced manifold va the new age of factory au ase Mounted Type Space saving profile Clean space saving design with all pilot

More information

Series SV1000/2000/3000/4000

Series SV1000/2000/3000/4000 Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Rubber Seal Port Solenoid Valve Series Manifold Single Unit ase Mounted Manifold VV01 V100 ar base P.18 ody Ported P.10 ase Mounted P.10 VQD VKF VK VT VS Separable base ody Ported Manifold P.1 Stacking

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators

More information

Series SYA3000/5000/7000

Series SYA3000/5000/7000 Port Air Operated Valve Series SYA000/000/7000 How to Order A, B port size Thread type Thread piping (Inch size) Nil Rc Symbol Port size Applicable series Symbol Port size Applicable series F G M SYA000

More information

Series ITV1000/2000/3000

Series ITV1000/2000/3000 Electro-Pneumatic Regulator Series ITV// How to Order [Option] RoHS ITV S Model type type type Pressure range 5 MPa MPa.9 MPa CE compliant Nil Q CE compliant Note) Refer to pages, 5, and 6 for information

More information

2005 / 2012 / 2035 Series

2005 / 2012 / 2035 Series 005 / 0 / 035 Series Accessories Sandwich Pressure Regulators Accessory Description 0. to bar - 005 Regulator repair kit 0.3 to bar - 0.7 to 9 bar -3 0. to bar 39-909 0 Regulator repair kit 0.3 to bar

More information

Plug Lead Unit: Flip Type

Plug Lead Unit: Flip Type Series ody orted lug Lead Unit: Flip Type For details about certified products conforming to international standards, visit us at www.smcworld.com. 0 Series Kit/Electrical entry/cable length F kit (D-sub

More information

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series VZS Series Variations Plug-in Type Base Mounted Type (With sub-plate) Non Plug-in Type Base Mounted Type (With sub-plate) Series Sonic conductance

More information

Manifold Specifications

Manifold Specifications Specifications Plug-in Type: With Terminal Block Since lead wires of solenoid valve are connected with the terminals on upper surface of terminal block, corresponding lead wires from power source can be

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable

More information

SVR10 SVA10. External Pilot air specification. Conventional specification 0 ~ 0.7. Compact, yet keeps large capacity.» Limited space can be utilized.

SVR10 SVA10. External Pilot air specification. Conventional specification 0 ~ 0.7. Compact, yet keeps large capacity.» Limited space can be utilized. Compact, yet keeps large capacity.» Limited space can be utilized. Standard.» SVR 10 series takes over the functions (Valve variations) of discontinued SVA 10 series. Pneumatic Symbols 1(P) 1(P) 1(P) 1(P)

More information

Series SYA3000/5000/7000

Series SYA3000/5000/7000 Port Air Operated Valve Series SYA000/000/7000 How to Order A, B port size Thread type Thread piping (Inch size) - Rc Symbol Port size Applicable series Symbol Port size Applicable series F G SYA000 N

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

Select from 3 product types and 14 protocols.

Select from 3 product types and 14 protocols. Fieldbus System Select from 3 product types and 14 protocols. * Some protocols are not UL-compliant. Type 1 Type 2 Type 3 Output type for solenoid valves Gateway type Integrated input-output type CAT.E02-27A

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Series 000 Compact and lightweight: 3 mm width Compact yet provides

More information

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing

More information

5 Port Air Operated Valve. Specifications. Flow characteristics 1 4/2(P A/B) Cv

5 Port Air Operated Valve. Specifications. Flow characteristics 1 4/2(P A/B) Cv 5 Port Air Operated Valve Series 000 Model (With sub-plate) Valve model -M5 -M5 3-M5 -M5 --0 --0 --0 --0 3--0 3--0 --0 --0 position 3 position position 3 position Type of actuation Single Double Closed

More information

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold Compact Electro-Pneumatic Regulator Series ITV How to Order For single unit and single unit for manifold ITV N Q Pressure range. MPa MPa.9 MPa Power supply voltage 4 VDC ±% to VDC Cable connector N S L

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to New Series Reduced wiring Series

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to

More information

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308 Cable ppendix Cable ppendix Multi-way cables The multi-pole connector cables used on SMC valves are common across several ranges. Cables are available in accordance with the MIL standard C-08 and also

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 0 PW COM Rubber Seal Port Solenoid Valve Series SZ000 Cassette Type Manifold The plug-in cassette system makes valve replacement easy. plug-in manifold has been created with a height of. mm (including

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type20P 5 Port Solenoid Valve ody Ported Manifold ar Stock Type/Flat Ribbon Cable Series SY3000/5000/7000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 5 20P 05 Manifold series 3 SY3000

More information

ISO Interface. Large capacity. Light weight. Accommodates enclosure IP65. Solenoid Valve (with M Connector) Conforming to ISO

ISO Interface. Large capacity. Light weight. Accommodates enclosure IP65. Solenoid Valve (with M Connector) Conforming to ISO P-EX01-A Solenoid Valve (with M Connector) Conforming to ISO 1507-1, Large capacity EVS1-01 (Size: 01) EVS1-0 (Size: 0) Light weight Size 01 (-position): 0.6kg Size 0 (-position): 0.18kg Flow rate 1000L/min

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators

More information

Series SYA3000/5000/7000

Series SYA3000/5000/7000 Port Air Operated Valve Series SYA000/000/7000 How to Order A, B port size Thread type Thread piping (Inch size) Nil Rc Symbol Port size Applicable series Symbol Port size Applicable series F G M SYA000

More information

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Vacuum / Release Unit Series VQD1000-V Rubber Seal Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area [Option] Smooth detachment of a work piece without

More information

42 Series MAConnect TM. 42 Series Plug-In Manifold

42 Series MAConnect TM. 42 Series Plug-In Manifold 42 Series MAConnect TM 42 Series Plug-In Manifold Specifications 42 Series Valve Operating Data Fluids: Lubrication: Safe Operating Temperature Range: Pressure Range: Electrical: Air or Inert Gas Not Required.

More information

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1 Port Solenoid Valve Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Non plug-in manifold 0 0 S 60 Stations stations 0 stations SUP/EXH

More information

Vacuum / Release Unit

Vacuum / Release Unit Rubber Seal Vacuum / Release Unit Series VQD1000-V Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area Smooth detachment of a work piece without over-blow

More information

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted

More information

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A Type N SY/ ase ounted anifold Stacking Type/DIN Rail ounted Connector ox How to Order anifold SSY SY SY Specifications Symbol Specifications With connector box (CO spec.) N With connector box ( CO spec.)

More information

Electro-Pneumatic Regulator/Electronic Vacuum Regulator

Electro-Pneumatic Regulator/Electronic Vacuum Regulator Electro-Pneumatic Regulator/Electronic Vacuum Regulator Series Stepless control of air pressure proportional to an electrical signal // series are compatible with various input specifications, including

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion

More information

2.26 S OLENOID VALVES S ERIES VQ1000

2.26 S OLENOID VALVES S ERIES VQ1000 2.26 S OLENOID VALVES 5 PORT M ETAL S EAL/RUBBER S EAL U LTRA H IGH S PEED S OLENOID VALVE High Speed Response from new Solenoid Design. Long Life: Over 200 Million Cycles can be with Patent Pilot Valve

More information