Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Size: px
Start display at page:

Download "Electro-Pneumatic Regulators. Electronic Vacuum Regulators"

Transcription

1 Electro-Pneumatic Regulator Electronic Vacuum Regulator Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to New Series Reduced wiring Series ITV//! Applicable Fieldbus protocols Compact/lightweight (Integrated communicatioin parts) Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators Series ITV Maximum flow rate 6 l/min (ANR) Set pressure:.6 MPa Supply pressure:. MPa Built-in communication board, so no converter needed. Added RS-C specification to serial communications! Note ) Value for communications type. (PROFIBUS DP) Note ) ITV. Dimensions in parentheses ( ) are for the CC-Link or PROFIBUS DP. Series ITV Maximum flow rate l/min (ANR) Set pressure:.6 MPa Supply pressure:. MPa Grease-free specification (wetted parts) RoHS New IP6 Note ) 98(8) Series ITV Maximum flow rate l/min (ANR) Set pressure:.6 MPa Supply pressure:. MPa Series ITV Maximum flow rate 4 l/min (ANR) Set pressure:.6 MPa Supply pressure:. MPa Electronic Vacuum Regulators Series ITV9 Series ITV9 Series ITV CAT.EUS6-F-UK

2 Compact Electro-Pneumatic Regulator Series ITV Compact Vacuum Regulator Series ITV9 Compact mm With a simplified high-density circuit board design, an extremely compact size has been achieved. Cable connectors Straight type and right angle type are available. Straight type Built-in One-touch fittings With error indication LED Brackets Flat and L-brackets are available. Right angle type Lightweight g Flat bracket L-bracket Series ITV9 Realizes space-saving and reduction of weight for manifold use. Stations can easily be increased or decreased due to DIN rail mount design. Model ITV ITV ITV ITV9 Pressure range. MPa MPa.9 MPa kpa Power supply voltage 4 VDC VDC Input signal Output signal Option Cable connectors 4 to ma DC Straight type Analogue to ma DC Right angle type output to VDC Brackets to V to VDC Flat bracket L-bracket Equivalent to IP6 Linearity: Within ±% (F.S.) Hysteresis: Within % (F.S.) Repeatability: Within ±% (F.S.) High-speed response time:. sec (Without load) High stability Sensitivity within.% (F.S.) Air Filter ( μm or less) Mist separator (. µm or less) ( µm or less) IR (Precision regulator) W ITV (Electro-pneumatic regulator) Electro-Pneumatic Regulator Series ITV// Electronic Vacuum Regulator Series ITV9 New Added Fieldbus compliant specifications to Series ITV//! Reduced wiring Applicable Fieldbus protocols ITV ITV Sensitivity: Within.% (F.S.) Linearity: Within ±% (F.S.) Hysteresis: Within % (F.S.) IP6 Cable connections in directions Straight type New Added RS-C specification to serial communications! Right angle type Application examples Multi-stage control to analogue control Controller s Pressure regulators OUT. Electro-pneumatic regulator OUT. Electrostatic coating control Mist separator SUP. Electro-pneumatic regulator Control signal ITV ITV9 Coating material SUP. Mist separator Mist separator Controller Coating nozzle Grease-free specification (Series ITV) SUP. Controller Analogue control Features

3 Electro-Pneumatic Regulator Electronic Vacuum Regulator Stepless control of air pressure proportional to an electrical signal. Series ITV Series Model Set pressure range Input signal Port size Page Series ITV ITV ITV ITV to. MPa to MPa to.9 MPa Current type: 4 to ma DC Current type: to ma DC Voltage type: to VDC Voltage type: to VDC Built-in One-touch fittings Metric size: ø4 Inch size: ø/ Electro-Pneumatic Regulator Series ITV Series ITV New New ITV ITV ITV ITV ITV ITV to. MPa to MPa to.9 MPa to. MPa to MPa to.9 MPa Current type: 4 to ma DC (Sink type) Current type: to ma DC (Sink type) Voltage type: to VDC Voltage type: to VDC Preset input New CC-Link compatible /8, /4 /4, /8 9 9 Series ITV New ITV to. MPa New DeviceNet compatible New PROFIBUS DP compatible New RS-C communication ITV to MPa /4, /8, / 9 ITV to.9 MPa Electronic Vacuum Regulator Series ITV9 Series ITV9 New ITV9 to kpa Current type: 4 to ma DC Current type: to ma DC Voltage type: to VDC Voltage type: to VDC Current type: 4 to ma DC (Sink type) Current type: to ma DC (Sink type) Voltage type: to VDC Built-in One-touch fittings Metric size: ø4 Inch size: ø/ ITV9. to 8 kpa Voltage type: /4 to VDC Preset input New CC-Link compatible New DeviceNet compatible New PROFIBUS DP compatible New RS-C communication 8 Features

4 PWR ERR PWR ERR Compact Electro-Pneumatic Regulator Series ITV For single unit and single unit for manifold ITV How to Order RoHS Pressure range. MPa MPa.9 MPa Power supply voltage 4 VDC ±% to VDC Cable connector (Option) N S L Without cable connector Straight type m Right angle type m Input signal Current type 4 to ma DC Current type to ma DC Voltage type to VDC Voltage type to VDC Bracket/Option for single unit only Without bracket Flat Bracket Built-in One-touch fittings type For single unit Symbol SUPz OUTx U Metric size (Light grey) Inch size (Orange) ø4 ø/" c B C L-bracket For manifold Symbol Metric size (Light grey) Inch size U (Orange) SUPz ø6 ø/4" OUTx ø4 ø/" c ø6 ø/4" Base type M For single unit For manifolds Manifold IITV n Stations stations stations stations One-touch fitting size for supply/ exhaust parts (End plate) U ø6 (Light grey) ø/4" (Orange) Option If a DIN rail longer than the specified stations is required, specify the applicable stations in two digits. (Maximum stations) Example) IITV--7 How to Order Manifold Assembly (Example) Indicate the part numbers of electro-pneumatic regulators and options to be mounted below the manifold part number. Example) Due to the common supply/exhaust feature, note that different pressure range combinations are not available. IITV- set (Manifold part no.) ITV-MS sets (Electro-pneumatic regulator part no. (, stations)) ITV-ML set (Electro-pneumatic regulator part no. ( stations)) Indicate part numbers in order starting from the first station on the D side. Note) Combination with having different pressure ranges is not available due to common supply/exhaust features. The asterisk ( ) specifies mounting. Add an asterisk ( ) at the beginning of electro-pneumatic regulator part numbers to be mounted. D side PWR ERR PWR ERR Note) A DIN rail with the length specified by the number of stations is attached to the manifold. For dimensions of the DIN rail, refer to the external dimensions. PWR ERR DIN rail ITV-MS ITV-ML

5 Compact Electro-Pneumatic Regulator Series ITV Specifications Accessories (Option) Bracket Model Minimum supply pressure Maximum supply pressure Set pressure range Maximum flow rate Power supply Input signal Input impedance Output signal Voltage Voltage type Current type Voltage type Current type Analogue output Linearity Hysteresis Repeatability Sensitivity Temperature characteristics Operating temperature range Enclosure Connection type Connection size Note ) Weight Current consumption For single unit Manifold Cable connector ITV. MPa to. MPa. l/min(anr) (Supply pressure:. MPa) ITV Set pressure +. MPa to MPa. MPa 6 l/min(anr) (Supply pressure:.6 MPa) 4 VDC ±%, to VDC to VDC, to VDC 4 to ma DC, to ma DC Approximately kω Approximately Ω Within ±% (Full span) Within % (Full span) Within ±% (Full span) Within.% (Full span) Within ±.% (Full span)/ C to C (No condensation) Equivalent to IP6 Built-in One-touch fittings Metric size z, x, c: ø4 Inch size z, x, c: ø/" Metric size z, c: ø6, x: ø4 Inch size z, c: ø/4", x: ø/" g or less (without option) ITV to.9 MPa 6 l/min(anr) (Supply pressure:.6 MPa) Power supply voltage 4 VDC type:. A or less Power supply voltage to VDC type:.8 A or less to VDC (Output impedance: Approximately kω) Output accuracy: Within ±6% (Full span) Note ) Indicates the weight of a single unit. For IITV-n Total weight (g) Stations (n) x + (Weight of end block A, B assembly) + Weight (g) of DIN rail Note ) When there is a downstream flow consumption, pressure may become unstable depending on piping conditions. Note ) When the power is turned on, a noise may be generated. This noise is normal and does not indicate a fault. When using under the conditions equivalent to IP6, connect the fitting or tube to the breathing hole prior to use. (For details, refer to "Specific Product Precautions " on page 4) Flat bracket assembly (includes mounting screws) P98 Straight type M8-4DSXMG4 L-bracket assembly (includes mounting screws) P98 Right angle type P98-- Tighting torque when assembling is. N m.

6 Series ITV Working Principle When the input signal rises, the air supply soloenoid q turns ON. Due to this, part of the supply pressure passes through the air supply solenoid q and changes to output pressure. This output pressure feeds back to the control circuit r via the pressure sensor e. Here, pressure corrections continue until output pressure becomes proportional to the input signal, enabling output pressure that is proportional to the input signal. Diagram of working principle Power supply and error LED indication Power supply Input signal r Control circuit Output signal q Air supply solenoid w Exhaust solenoid e Pressure sensor SUP OUT Block diagram Supply pressure Input signal + r Control circuit q Air supply solenoid w Exhaust solenoid Output pressure Discharged to atmosphere e Pressure sensor

7 Compact Electro-Pneumatic Regulator Series ITV Series ITV Linearity, Hyteresis Repeatability With % of signal input Output deviation factor [% F.S.] Return Out Output deviation factor (% F.S.) 7 Input signal [%F.S.] 4 Count Pressure Characteristics Set pressure: MPa Flow Characteristics Supply pressure:. MPa Output deviation factor [% F.S.] Out Return Set pressure (kpa) kpa 8 kpa 6 kpa 4 kpa kpa kpa Supply pressure [MPa].... Flow rate [l/min (ANR)] 4 Series ITV Linearity, Hyteresis Repeatability With % of signal input Output deviation factor [% F.S.] Return Out Output deviation factor [% F.S.] 7 Input signal [%F.S.] 4 Count Pressure Characteristics Set pressure:. MPa Flow Characteristics Supply pressure:.6 MPa 6 Output deviation factor [% F.S.] Out Return Set pressure [kpa] 4 kpa 4 kpa kpa kpa kpa kpa Supply pressure [MPa]. 4 6 Flow rate [l/min (ANR)] 7 4

8 Series ITV Series ITV Linearity, Hyteresis Output deviation factor [% F.S.] Return Out 7 Input signal [%F.S.] Repeatability Output deviation factor [% F.S.] 4 Count With % of signal input Pressure Characteristics Output deviation factor [% F.S.] Out Return Supply pressure [MPa] Set pressure:.4 MPa. Flow Characteristics Set pressure (kpa) Supply pressure:. MPa 9 9 kpa 8 kpa kpa 6 6 kpa kpa 4 4 kpa kpa kpa kpa kpa Flow rate [l/min (ANR)]

9 Compact Electro-Pneumatic Regulator Series ITV Dimensions For Single Unit x ø. 4 x ø SUP port (ø4, ø/") port (ø4, ø/") OUTx 89 SUPz c Note) Breathing hole (M x ) OUT port (ø4, ø/") 8 88 Port Location No. ITV z x c SUP OUT Note) When using under the conditions equivalent to IP6, connect the fittings or tube to the breathing hole prior to use. (For details, refer to "Specific Product Precautions " on page 4) x M x thread depth. Bracket mounting hole Flat bracket (Option) Flat bracket (Option) PWR ERR x ø6 depth of counterbore. L-bracket (Option) L-bracket (Option) M8 x Cable connection thread PWR ERR 4 x ø6 depth of counterbore + (.9) Minimum bending radius 8 Body ø4 Cable connector (4-wire) Straight type (Option) Cable connector (4-wire) Right angle type (Option).8 M8 x ø9.7 Minimum bending radius 8 Body 4.6 ø4 6

10 Series ITV Dimensions Single unit for manifold Bushing assembly Note) Breathing hole (M x ) OUTx 8 OUT port (ø4, ø/") Note) When using under the conditions equivalent to IP6, connect the fittings or tube to the breathing hole prior to use. (For details, refer to "Specific Product Precautions " on page 4) PWR ERR M8 x Cable connection thread Note) For dimensions of the cable connector, refer to single unit on page 6. 7

11 Compact Electro-Pneumatic Regulator Series ITV Dimensions Manifold D side stations U side 6 8 SUPz port (ø6, ø/4") c port (ø6, ø/4") OUTx port (ø4, ø/").7 9. PWR L L ERR PWR ERR 9. Note) Stations are counted starting from the D side (8) Dimensions in inch are noted in parentheses. 4 4 Note) Breathing hole (M x ) Note) When using under the conditions equivalent to IP6, connect the fittings or tubing to the breathing hole prior to use. (For details, refer to "Specific Product Precautions " on page 4). PWR ERR PWR ERR Port Location No. z x c ITV SUP OUT 4 x M x thread depth Mounting hole Note) For dimensions of the cable connector, refer to single unit on page 6. Manifold stations n L L Weight of DIN rail [g] [mm]

12 Electro-Pneumatic Regulator Series ITV// How to Order RoHS ITV F S Model type type type Pressure range. MPa MPa.9 MPa Input signal/ Communication model Current type 4 to ma DC (Sink type) Current type to ma DC (Sink type) 4 6 CC DE PR RC Voltage type to VDC Voltage type to VDC 4 points preset input 6 points preset input (Switch output/npn output) 6 points preset input (Switch output/pnp output) bit digital input CC-Link DeviceNet PROFIBUS DP RS-C communication Power supply voltage 4 VDC to VDC Note) Communication models (CC, DE PR, RC) are available only for 4 VDC. Monitor output Analogue output to VDC Switch output/npn output Switch output/pnp output Analogue output 4 to ma DC 4 Note ) (Sink type/+com type) None Note) For -COM type, see page for details. Thread type N T F Rc NPT NPTF G 4 MPa kgf/cm bar psi kpa Cable connector type S L N Bracket B C Pressure display unit Straight type m Right angle type m Without cable connector Without bracket Flat bracket L-bracket Made to Order Specifications Refer to pages,, 6 and 7 for details. Note) For the communication models, CC, DE, PR and RC, only is available as it does not have a pressure display. Note) Order communication cable (other than RS-C) separately. See below. Port size 4 /8 ( type) /4 (,, type) /8 (, type) / ( type) 9 For communication cables, use the parts listed below (refer to the catalogue [M8/M Connector] CAT.ES-7 for details) or order the product certified for the respective protocol (with M connector) separately. Application Communication cable part number Remarks CC-Link compatibility PCA-677 (Socket type) Dedicated Bus adapter supplied PCA-6777 with the product. DeviceNet PROFIBUS DP PCA-76 (Socket type) PCA-7688 (Socket type) compatibility compatibility PCA-7646 PCA-769 T-branch connector not supplied. T-branch connector not supplied.

13 Electro-Pneumatic Regulator Series ITV// ITV JIS Symbol Rated pressure Output pressure [MPa] ITV ITV Fieldbus-compatible model This range is outside of the control (output). MPa Input signal [%F.S.] Figure. Input/output characteristics chart Communication Specifications (CC, DE, PR, RC) Standard Specifications Model Minimum supply pressure Maximum supply pressure. Set pressure range Note ) Power supply Input signal Input impedance Note ) Output signal (monitor output) Linearity Hysteresis Repeatability Sensitivity Temperature characteristics Output pressure Accuracy display Note 4) Minimum unit Ambient and fluid temperature Enclosure Weight Note 9) Voltage Current consumption Current type Note ) Voltage type Preset input Current type Voltage type Preset input Analogue output Switch output ITV ITV ITV ITV ITV ITV ITV ITV ITV ITV ITV ITV Set pressure +. MPa MPa. MPa to. MPa to MPa to.9 MPa 4 VDC ±%, to VDC Power supply voltage 4 VDC type:. A or less Note 8) Power supply voltage to VDC type:.8 A or less 4 to ma DC, to ma DC (Sink type) to VDC, to VDC 4 points (Negative common), 6 points (No common polarity) Note 6) Ω or less Approx. 6. kω Power supply voltage 4 VDC type: Approx. 4.7 kω Power supply voltage VDC type: Approx.. kω to VDC (Output impedance: Approximately kω) 4 to ma DC (Sink type) (Load impedance: Ω or less) Output accuracy within ±6% (Full span) NPN open collector output: Max. V, 8 ma PNP open collector output: Max. 8 ma Within ±% (Full span) Within % (Full span) Within ±% (Full span) Within.% (Full span) Within ±.% (Full span)/c ±%F.S. ± digit MPa:, kgf/cm :, bar:, psi:. Note ), kpa: to C (No condensation) IP6 Approx. g (without options) Approx. g (without options) Approx. 64 g (without options) Note ) Note ) Note ) Note ) Please refer to Figure for the relationship between set pressure and input. Because the maximum set pressure differs for each pressure display, refer to page 4. Note ) -wire type 4 to ma DC is not available. Power supply voltage (4 VDC or to VDC) is required. Note ) Select either analogue output or switch output. Further, when switch output is selected, select either NPN output or PNP output. Note 4) Adjustment of numerical values such as the zero/span adjustment or preset input type is set based on the minimum units for output pressure display (e.g. to MPa). Note that the unit cannot be changed. Note ) The minimum unit for.9 MPa ( psi) types is psi. Note 6) Value for the state with no over current circuit included. If an allowance is provided for an over current circuit, the input impedance varies depending on the input current. This is Ω or less for an input current of ma DC. Note 7) The above characteristics are confined to the static state. When air is consumed on the output side, the pressure may fluctuate. Note 8) For communication models, the maximum current consumption is.6 A or less. Note 9) For communication models, add roughly 8 g to the weight ( g for the PROFIBUS DP). Note ) The ITV series is a Grease-free specification (Wetted parts). Model Protocol Version Note ) Communication speed Configulation file Note ) I/O occupation area (input/output data) Communication data resolution Fail safe ITV -CC CC-Link Ver. 6 k/6 k. M/ M/ M bps 4 word/4 word, bit/ bit (per station, remote device station) bit (496 resolution) HOLD Note ) /CLEAR (Switch setting) ITV -DE DeviceNet Volume (Edition.8), Volume (edition.) k/ k/ k bps Terminating Built into the product resistor (Switch setting) Note ) Note that version information is subject to change. Note ) Configulation files can be downloaded from the SMC's website: Note ) The output HOLD value when a CC-Link communications error occurs can be set based on the bit area data. Note 4) The insulation between the electrical signal of the communication system and ITV power supply. EDS 6 bit/6 bit bit (496 resolution) HOLD/CLEAR (Switch setting) ITV -PR PROFIBUS DP DP-V 9.6 k/9. k/4.4 k 9.7 k/87. k/ k. M/ M/6 M/ M bps GSD 6 bit/6 bit bit (496 resolution) CLEAR ITV -RC RS-C 9.6 kbps bit (4 resolution) Electric insulation Note 4) No No Yes No HOLD

14 Series ITV// Combinations Standard specifications Combination possible Combination not possible ITV models are not applicable. Applicable model rspacer ITV Specifications Symbol ITV ITV 89 qaf 78 wafm el-bracket ITV Standard specifications Accessories Optional specifications Set pressure max.. MPa Set pressure max. MPa Set pressure max..9 MPa Connection Rc /4 Connection Rc /8 Connection Rc / Bracket Bracket Connection NPT/4 Connection NPT/8 Connection NPT/ Connection G /4 Connection G /8 Connection G / 4 B C N N N4 F F F4 Modular Products and Accessory Combinations 4 7 qaf4 4 wafm4 Applicable products and accessories q Air filter w Mist separator e L-bracket r Spacer t Spacer with L-bracket (e + r) y Spacer with T-bracket Accessories (Option)/Part No. ITV models are not applicable. Applicable model ITV ITV AF AF4 AFM AFM4 BL B4L Y Y4 YL Y4L Y4T Order Made Made to Order (Refer to pages, 6 and 7 for details.) Symbol CE-compliant X6 X7 Compliant Compliant Specifications Monitor analogue output 4-mA (source type/-com type) Digital input type L-bracket assembly (including mounting screws) Power cable connector Description Flat bracket assembly (including mounting screws) Straight type m Right angle type m Bus adapter (CC-Link model only) Part No. ITV ITV ITV KT-ITV-F KT-ITV-F KT-ITV-L KT-ITV-L P98-- P98-- EX9-ACY-MJ X Compliant Reverse type Dimensions X4 X Compliant Compliant High pressure type (SUP. MPa, OUT. MPa) Set pressure range to kpa (Except Series ITV) Flat bracket 6 L-bracket 4 6 X4 X4 Compliant Compliant Linearity ±% F.S. or less With alarm output.6 8 x ø4. 4 x ø X88 X6 Compliant Compliant High speed response type (Except Series ITV) For manifold mounting (Except Series ITV) 4 8 x ø x ø. Note ) Manifolds are compatible with to 8 stations. Consult with SMC for 9 stations or more. Note ) Products without symbols are also compatible. Consult with SMC separately. 4 x ø (8.) 4 x R.

15 Electro-Pneumatic Regulator Series ITV// Working Principles When the input signal rises, the air supply solenoid q turns ON, and the exhaust solenoid w turns OFF. Therefore, supply pressure passes through the air supply solenoid q and is applied to the pilot chamber e. The pressure in the pilot chamber e increases and operates on the upper surface of the diaphragm r. As a result, the air supply t linked to the diaphragm r opens, and a portion of the supply pressure becomes output pressure. This output pressure feeds back to the control circuit i via the pressure sensor u. Here, a correct operation functions until the output pressure is proportional to the input signal, making it possible to always obtain output pressure proportional to the input signal. Working Principle Diagram Pressure display Pressure display Power supply Input signal i Control circuit Output signal Power supply Input signal q Air supply solenoid r Diaphragm i Control circuit Output signal w Exhaust solenoid u Pressure sensor e Pilot chamber t Supply q Air supply solenoid r Diaphragm y Exhaust t Supply w Exhaust solenoid u Pressure sensor e Pilot chamber SUP OUT SUP OUT ITV ITV, Block diagram Supply pressure Input signal i Control circuit q Air supply solenoid r Diaphragm Pilot Output pressure w Exhaust solenoid u Pressure sensor

16 Series ITV// Series ITV Linearity Hysteresis.. Out Return Input signal [%F.S.] Input signal [%F.S.] Repeatability Repetition Pressure characteristics Set pressure: MPa. Set point.... Supply pressure [MPa] Flow characteristics Supply pressure:. MPa Flow rate [l/min (ANR)] Relief flow characteristics Supply pressure:. MPa Flow rate [l/min (ANR)] Series ITV Linearity Input signal [%F.S.] Hysteresis. Out Return. 7 Input signal [%F.S.] Repeatability Repetition Pressure characteristics Set pressure: MPa. Set point.... Supply pressure [MPa] Flow characteristics Supply pressure:. MPa 4 6 Flow rate [l/min (ANR)] Relief flow characteristics Supply pressure:. MPa Flow rate [l/min (ANR)]

17 Electro-Pneumatic Regulator Series ITV// Series ITV Linearity Input signal [%F.S.] Hysteresis. Out. 7 Input signal [%F.S.] Return Repeatability Repetition Pressure characteristics Set pressure: MPa. Set point.... Supply pressure [MPa] Flow characteristics Supply pressure:. MPa Flow rate [l/min (ANR)] Relief flow characteristics Supply pressure:. MPa.. Flow rate [l/min (ANR)] 4

18 Series ITV// Series ITV Linearity.6 Hysteresis. Repeatability Out Return 7 Input signal [%F.S.]. 7 Input signal [%F.S.] Repetition Pressure characteristics Set pressure:. MPa. Set point Supply pressure [MPa] Flow characteristics Supply pressure:.7 MPa Flow rate [l/min (ANR)] Relief flow characteristics Supply pressure:.7 MPa Flow rate [l/min (ANR)] Series ITV Linearity.6 Hysteresis. Repeatability Out Return 7 Input signal [%F.S.]. 7 Input signal [%F.S.] Repetition Pressure characteristics. Set pressure:. MPa Set point Flow characteristics Supply pressure:.7 MPa Relief flow characteristics Supply pressure:.7 MPa Supply pressure [MPa].8 Flow rate [l/min (ANR)] Flow rate [l/min (ANR)]

19 Electro-Pneumatic Regulator Series ITV// Series ITV Linearity Hysteresis. Out Return Repeatability. 7 Input signal [%F.S.]. 7 Input signal [%F.S.] Repetition Pressure characteristics. Set pressure:. MPa Set point Flow characteristics Supply pressure:.7 MPa Relief flow characteristics Supply pressure:.7 MPa Supply pressure [MPa] Flow rate [l/min (ANR)] 4 Flow rate [l/min (ANR)] 6

20 Series ITV// Series ITV Linearity Input signal [%F.S.] Hysteresis. Out Return. 7 Input signal [%F.S.] Repeatability Repetition Pressure characteristics Set pressure:.4 MPa. Set point Supply pressure [MPa] Flow characteristics Flow rate [l/min (ANR)] Supply pressure:. MPa Relief flow characteristics Supply pressure:. MPa Flow rate [l/min (ANR)] Series ITV Linearity Input signal [%F.S.] Hysteresis. Out Return. 7 Input signal [%F.S.] Repeatability Repetition Pressure characteristics Set pressure:.4 MPa. Set point Supply pressure [MPa] Flow characteristics Supply pressure:. MPa Flow rate [l/min (ANR)] Relief flow characteristics Supply pressure:. MPa Flow rate [l/min (ANR)] 7

21 Electro-Pneumatic Regulator Series ITV// Series ITV Linearity..9 Hysteresis. Repeatability Input signal [%F.S.] Out Return. 7 Input signal [%F.S.] Repetition Pressure characteristics Set pressure:.4 MPa. Set point Supply pressure [MPa] Flow characteristics Flow rate [l/min (ANR)] Supply pressure:. MPa Relief flow characteristics Flow rate [l/min (ANR)] Supply pressure:. MPa 8

22 Series ITV// Dimensions ITV Flat bracket. M x Connector Straight type (4-wire) Cable connector m 84 4 () Rc /8 Exhaust port 7 M x () 8. SUP OUT.6 x Rc /8, /4 SUP port, OUT port Flat bracket assembly KT-ITV-F (Option). 4 4 x M4 x.7 thread depth 6 mm through Right angle type (4-wire) Cable connector m () 4 x ø7 Mounting hole Setting part Note) Do not attempt to rotate, as the cable connector does not turn. L-bracket. 7 4 L-bracket assembly KT-ITV-L (Option) (8.) 9

23 Electro-Pneumatic Regulator Series ITV// Dimensions (CC-Link, DeviceNet, PROFIBUS DP and RS-C) CC-Link/ITV -CC M x Communication cable connection thread (Socket type) M x Communication cable connection BUS adapter thread M x Power cable connection thread () () DeviceNet /ITV -DE M x Power cable connection thread M x Communication cable connection thread 8. () 8. Rc /8 Exhaust port M x 8 Rc /8 Exhaust port M x () SUP () OUT () () SUP () OUT () 98 x Rc /8, /4 SUP port, OUT port x Rc /8, /4 SUP port, OUT port Dimensions not shown are as on page 9. Dimensions not shown are as on page 9. PROFIBUS DP/ITV -PR M x Communication cable connection thread (Socket type) 9. Rc/8 Exhaust port (6) M x M x Power cable connection thread M x. 8 () RS-C/ITV -RC Communication cable connection thread 8. Rc/8 Exhaust port M x M x Power cable connection thread () SUP () OUT () () SUP () OUT () () 98 x Rc /8, /4 SUP port, OUT port Dimensions not shown are as on page 9. x Rc /8, /4 SUP port, OUT port Dimensions not shown are as on page 9. With power cable connector ITV - Note) Order communication cable (other than RS-C) separately. (Refer to page 9.) CC DE PR RC Right angle type (4-wire) Cable connector m common dimensions Straight type (4-wire) Cable connector m () Note) Do not attempt to rotate, as the cable connector does not turn.

24 Series ITV// Dimensions ITV Flat bracket. () M x Connector Rc /4 Exhaust port 9 M x.8. () 9 SUP () OUT () 84 4 x Rc /4, /8 SUP port, OUT port Flat bracket assembly KT-ITV-F (Option) 6 4 x M x.8 thread depth 6 mm through.6 Right angle type (4-wire) Cable connector m Straight type (4-wire) Cable connector m 4 x ø7 Mounting hole Note) Do not attempt to rotate, as the cable connector does not turn. L-bracket 4 x R. () L-bracket assembly KT-ITV-L (Option) (8.)

25 Electro-Pneumatic Regulator Series ITV// Dimensions (CC-Link, DeviceNet, PROFIBUS DP and RS-C) CC-Link/ITV -CC M x Communication cable connection thread (Socket type) M x Communication cable connection BUS adapter thread M x Power cable connection thread () () DeviceNet /ITV -DE M x Power cable connection thread M x Communication cable connection thread 8. () 8. Rc /4 Exhaust port M x.8 Rc /4 Exhaust port M x.8 () SUP () OUT () () SUP () OUT () x Rc /4, /8 SUP port, OUT port Dimensions not shown are as on page. x Rc /4, /8 SUP port, OUT port Dimensions not shown are as on page. PROFIBUS DP/ITV -PR M x Communication cable connection thread (Socket type) 9. Rc /4 Exhaust port () (6) M x.8 M x Power cable connection thread. () RS-C/ITV -RC 8. M x Communication cable connection thread Rc /4 Exhaust port M x Power cable connection thread M x.8 SUP () OUT () () SUP () OUT () () x Rc /4, /8 SUP port, OUT port Dimensions not shown are as on page. x Rc /4, /8 SUP port, OUT port Dimensions not shown are as on page. With power cable connector ITV - Note) Order communication cable (other than RS-C) separately. (Refer to page 9.) CC DE PR RC common dimensions Right angle type (4-wire) Cable connector m Straight type (4-wire) Cable connector m () Note) Do not attempt to rotate, as the cable connector does not turn.

26 Series ITV// Dimensions ITV Flat bracket. () M x Connector M x.8 4. () (66) SUP () OUT () Right angle type (4-wire) Cable connector m Straight type (4-wire) Cable connector m 4 4 x ø7 Mounting hole x M x.8 thread depth 6 mm through 6 x Rc /4, /8, /4 SUP port, OUT port Flat bracket assembly KT-ITV-F (Option) Note) Do not attempt to rotate, as the cable connector does not turn. () L-bracket 4 x R L-bracket assembly KT-ITV-L (Option) (8.) 6

27 Electro-Pneumatic Regulator Series ITV// Dimensions (CC-Link, DeviceNet, PROFIBUS DP and RS-C) CC-Link/ITV -CC M x Communication cable connection thread (Socket type) M x Communication cable BUS adapter connection thread M x Power cable connection thread () DeviceNet /ITV -DE 8. M x Power cable connection thread M x Communication cable connection thread 8. () () M x.8 () () 4 M x.8 SUP () OUT () SUP () OUT ().6 x Rc/4, /8, /4 SUP port, OUT port x Rc /4, /8, /4 SUP port, OUT port () ().6 Dimensions not shown are as on page. Dimensions not shown are as on page. PROFIBUS DP/ITV -PR M x Communication cable connection thread (Socket type) M x Power cable connection thread (6). RS-C/ITV -RC M x Communication cable connection thread M x Power cable connection thread.6 M x.8 () () SUP () OUT ().6 4 M x.8 SUP () OUT () x Rc /4, /8, /4 SUP port, OUT port Dimensions not shown are as on page. x Rc /4, /8, /4 SUP port, OUT port Dimensions not shown are as on page. With power cable connector ITV - CC DE PR RC common dimensions () Right angle type (4-wire) Cable connector m Straight type (4-wire) Cable connector m Note) Do not attempt to rotate, as the cable connector does not turn. 4

28 Series ITV// Made to Order Specifications Please contact SMC for detailed dimensions, specifications and lead times. Made to Order ITV Monitor Analogue output 4-mA (source type/-com) Note ) in part number is the same model no. for the standard products. 4 X6 4 High Pressure Type (SUP. MPa, OUT. MPa) ITV X4 ITV X4 ITV X4 High pressure type (SUP. MPa, OUT. MPa) Digital Input Type Set Pressure Range to kpa Parallel input type with digital bit. ITV 4 ITV 4 ITV 4 S N S N S N X7 X7 X7 ITV ITV Set pressure range to kpa X X Digital input type Note ) in part number is the same model no. for the standard products. Note ) Right angle type cable connectors cannot be selected. Reverse Type In compliance with input, inverse proportional pressure is displayed. ITV X ITV X ITV X Rated pressure Reverse type Output pressure (MPa) This range is outside of the control (output). MPa Input signal (%F.S.) Input/output characteristics chart Note ) in part number is the same model no. for the standard products. Note ) Except for preset input type.

29 Series ITV// Made to Order Specifications Please contact SMC for detailed dimensions, specifications and lead times. Made to Order 6 Power supply voltage Linearity: ±% F.S. or less 4 Model type type type 4 VDC to VDC ITV Monitor output Analogue output to VDC Switch output/npn output Switch output/pnp output Analogue output 4 to ma DC (Sink type) S Pressure range. MPa MPa.9 MPa Input signal Current type 4 to ma DC (Sink type) Current type to ma DC (Sink type) Voltage type to VDC Voltage type to VDC Thread type N T F Rc NPT NPTF G Port size 4 /8 ( type) /4 (,, type) /8 (, type) / ( type) X4 Pressure display unit 4 Bracket B C MPa kgf/cm bar psi kpa Cable connector type S L N Straight type m Right angle type m Without cable connector Linearity: ±% F.S. or less Without bracket Flat bracket L-bracket 7 Power supply voltage With Alarm Output t Alarm is output if the set pressure is not reached or maintained for seconds or more. Model type type type 4 VDC to VDC ITV S Pressure range. MPa MPa.9 MPa Input signal Current type 4 to ma DC (Sink type) Current type to ma DC (Sink type) Voltage type to VDC Voltage type to VDC Monitor output Alarm output/npn output Alarm output/pnp output Thread type N T F Rc NPT NPTF G Port size 4 /8 ( type) /4 (,, type) /8 (, type) / ( type) X4 With alarm output Pressure display unit 4 Bracket B C MPa kgf/cm bar psi kpa Cable connector type S L N Straight type m Right angle type m Without cable connector Without bracket Flat bracket L-bracket 6

30 Series ITV// Made to Order Specifications Please contact SMC for detailed dimensions, specifications and lead times. Made to Order 8 High-Speed Response Time Type Pressure response with no load is approx.. sec. Power supply voltage Model type type 4 VDC to VDC ITV S Pressure range. MPa MPa.9 MPa Input signal Current type 4 to ma DC (Sink type) Current type to ma DC (Sink type) Voltage type to VDC Voltage type to VDC Monitor output Analogue output to VDC X88 Pressure display unit Symbol MPa X88 kgf/cm X4 bar 4 psi kpa Under Japan's new Measurement Act, this is only for overseas sales (SI units are to be used inside Japan). Cable connector type S L N Straight type m Right angle type m Without cable connector High-speed response time specifications CE-compliant Not compliant Compliant Thread type N T F Rc NPT NPTF G Port size /8 ( type) /4 (, type) /8 ( type) Bracket B C Without bracket Flat bracket L-bracket 9 Manifold Specifications (Except Series ITV) through 8 station manifold. How to Order Manifolds IITV Stations stations 8 8 stations How to Order Manifold Assemblies Example Electro-pneumatic regulator ITV-S-X6 Blanking plate assembly P98- Electro-pneumatic regulator ITV-S-X6 ITV, OUT port size /4 /8 Connection thread type N F PT NPT PF IITV-- set ( station manifold base part no.) ITV-S-X6 set (Electro-pneumatic regulator part no.) Note ) P98- set (Blanking plate assembly part no.) ITV-S-X6 set (Electro-pneumatic regulator part no.) Note ) The is the symbol for mounting. Add the symbol at the beginning of part numbers for electro-pneumatic regulators, etc. to be mounted on the base. Note) Refer to the table below for possible mixed combination. Model ITV ITV ITV ITV ITV ITV ITV ITV ITV ITV ITV ITV 7 Manifold base ( stations) IITV-- Stations Note ) Note ) Electro-pneumatic regulators are counted starting from station on the left side with the OUT ports in front. Note ) The port size for mounted electro-pneumatic regulators is Rc /8 (ITV), Rc /4 (ITV) only. Note ) When there is a large number of stations, use piping with the largest possible inside diameter for the supply side, such as steel piping. Note 4) The use of the straight type cable connector is recommended. To mount right angle type, be certain to check that no possible interference occurs. Note ) When mounting a blanking plate and the regulator with different pressure set, please inform SMC of the order of a manifold station beside a purchase order.

31 Compact Vacuum Regulator Series ITV9 RoHS How to Order For single unit and single unit for manifold ITV 9 Pressure range 9 kpa Power supply voltage 4 VDC ±% to VDC N Cable connector (Option) N Without cable connector S Straight type m L Right angle type m Input signal Current type 4 to ma DC Current type to ma DC Voltage type to VDC Voltage type to VDC Bracket/Option for single unit only Without bracket Flat Bracket PWR ERR Built-in One-touch fittings type For single unit Symbol VACz OUTx U Metric size (Light grey) Inch size (Orange) ø4 ø/" ATMc B C L-bracket PWR ERR For manifold Symbol Metric size (Light grey) Inch size U (Orange) VACz ø6 ø/4" OUTx ø4 ø/" ATMc ø6 ø/4" Base type M For single unit For manifolds Manifold IITV n Stations stations stations stations Option If a DIN rail longer than the specified stations is required, specify the applicable stations in two digits. (Maximum stations) Example) IITV--7 Note) A DIN rail with the length specified by the number of stations is attached to the manifold. For dimensions of the DIN rail, refer to the external dimensions. How to Order Manifold Assembly (Example) Indicate the part numbers of electro-pneumatic regulators and options to be mounted below the manifold part number. Example) Due to the common supply/exhaust feature, note that different pressure range combinations are not available. IITV- set (Manifold part no.) ITV9-MS sets (Vacuum regulator part no. (, stations)) ITV9-ML set (Vacuum regulator part no. ( stations)) Indicate part numbers in order starting from the first station on the D side. Note) Combination with having different pressure ranges is not available due to common supply/exhaust features. The asterisk ( ) specifies mounting. Add an asterisk ( ) at the beginning of electro-pneumatic regulator part numbers to be mounted. D side PWR ERR PWR ERR PWR ERR DIN rail ITV9-MS ITV9-ML 8

32 Series ITV9 Specifications Model Minimum supply pressure Maximum supply pressure Set pressure range Maximum flow rate ITV9 Set pressure kpa kpa to kpa l/min (ANR) (Supply pressure: kpa) Accessories (Option) Bracket Voltage Power supply Current consumption Voltage type Input signal Current type Voltage type Input impedance Current type Analogue Output signal output Linearity Hysteresis Repeatability Sensitivity Temperature characteristics Operating temperature range Enclosure Connection type For single Metric size unit Inch size Connection size Metric size Manifold Inch size Weight Note ) Cable connector 4 VDC ±%, to VDC Power supply voltage 4 VDC type:. A or less Power supply voltage to VDC type:.8 A or less to VDC, to VDC 4 to ma DC, to ma DC Approximately kω Approximately Ω to VDC (Output impedance: Approximately kω) Output accuracy: Within ±6% (Full span) Within ±% (Full span) Within % (Full span) Within ±% (Full span) Within.% (Full span) Within ±.% (Full span)/ C to C (No condensation) IP6 equivalent Built-in One-touch fittings z, x, c: ø4 z, x, c: ø/" z, c: ø6, x: ø4 z, c: ø/4", x: ø/" g or less (without option) Note ) Indicates the weight of a single unit. For IITV-n Total weight (g) Stations (n) x + (Weight of end block A, B assembly) + Weight (g) of DIN rail Note ) When there is a downstream flow consumption, pressure may become unstable depending on piping conditions. When using under the conditions equivalent to IP6, connect the fitting or tube to the breathing hole prior to use. (For details, refer to "Specific Product Precautions " on page 4) Flat bracket assembly (including mounting screws) P98 Straight type M8-4DSXMG4 L-bracket assembly (including mounting screws) P98 Right angle type P98-- Tighting torque when assembling is. N m. 9

33 Compact Vacuum Regulator Series ITV9 Working Principle When the input signal rises, the air supply soloenoid q turns ON. Due to this, part of the supply pressure passes through the air supply solenoid q and changes to output pressure. This output pressure feeds back to the control circuit r via the pressure sensor e. Here, pressure corrections continue until output pressure becomes proportional to the input signal, enabling output pressure that is proportional to the input signal. Diagram of working principle Power supply and error LED indication Power supply Input signal r Control circuit Output signal q Air supply solenoid w Exhaust solenoid e Pressure sensor VAC ATM OUT Block diagram Supply pressure Input signal + r Control circuit q Air supply solenoid w Exhaust solenoid Output pressure Discharged to atmosphere e Pressure sensor

34 Series ITV9 Series ITV9 Linearity, Hyteresis Repeatability With % of signal input Output deviation factor [% F.S.] Return Out Output deviation factor [% F.S.] 7 4 Input signal [%F.S.] Count Pressure Characteristics Set pressure: kpa Flow Characteristics Output deviation factor [% F.S.] Out Return Set pressure [kpa] kpa kpa 4 kpa 6 kpa 8 kpa kpa Supply pressure [kpa] Flow rate [l/min (ANR)]

35 Compact Vacuum Regulator Series ITV9 Dimensions For Single Unit x ø. 4 x ø VAC port (ø4, ø/") OUTx 89 VACz ATMc Note) Breathing hole (M x ) OUT port (ø4, ø/") 88 ATM port (ø4, ø/") 8 Port Location No. ITV9 z x c VAC OUT ATM Note) When using under the conditions equivalent to IP6, connect the fittings or tube to the breathing hole prior to use. (For details, refer to "Specific Product Precautions " on page 4) x M x thread depth. Bracket mounting hole Flat bracket (Option) PWR ERR Flat bracket (Option) x ø6 depth of counterbore. L-bracket (Option) L-bracket (Option) M8 x Cable connection thread PWR ERR 4 x ø6 depth of counterbore + (.9) Minimum bending radius 8 Body ø4 Cable connector (4-wire) Straight type (Option) Cable connector (4-wire) Right angle type (Option) 8 M8 x ø9.7 Minimum bending radius 8 Body 4.6 ø4

36 Series ITV9 Dimensions Single unit for manifold Bushing assembly Note) Breathing hole (M x ) OUTx 8 OUT port (ø4, ø/") Note) When using under the conditions equivalent to IP6, connect the fittings or tube to the breathing hole prior to use. (For details, refer to "Specific Product Precautions " on page 4) 6 PWR ERR M8 x Cable connection thread Note) For dimensions of the cable connector, refer to single unit on page.

37 Compact Vacuum Regulator Series ITV9 Dimensions Manifold D side stations U side 6 9. L L PWR ERR (8) PWR ERR Dimensions in inch are noted in parentheses VACz port (ø6, ø/4") 4 4 ATMc port (ø6, ø/4") Note) Breathing hole (M x ) Note) When using under the conditions equivalent to IP6, connect the fittings or tubing to the breathing hole prior to use. (For details, refer to "Specific Product Precautions " on page 4) OUTx port (ø4, ø/").7 PWR ERR PWR ERR Port Location No. z x c ITV9 VAC OUT ATM Note) Stations are counted starting from the D side. 4 x M x thread depth Mounting hole Note) For dimensions of the cable connector, refer to single unit on page. [mm] Manifold stations n L L Weight of DIN rail [g]

38 Electronic Vacuum Regulator Series ITV9/9 How to Order RoHS ITV 9 F S Pressure range 9. to 8 kpa Power supply voltage 4 VDC to VDC Note) Communication models are available only for 4 V DC. Pressure display unit kpa Note) For the communication models, CC, DE, PR and RC, only is available as it does not have a pressure display. Input signal/ Communication model 4 6 CC DE PR RC Current type 4 to ma DC (Sink type) Current type to ma DC (Sink type) Voltage type to VDC Voltage type to VDC 4 points preset input 6 points preset input (Switch output/npn output) 6 points preset input (Switch output/pnp output) bit digital input CC-Link DeviceNet PROFIBUS DP RS-C communication Monitor output Analogue output to VDC Switch output/npn output Switch output/pnp output Analogue output 4 to ma DC 4 (Sink type) None Bracket B C Port size /4 Thread type N T F Rc NPT NPTF G Cable connector type S Straight type m L Right angle type m N Without cable connector Note) Order communication cable (other than RS-C) separately. See below. Without bracket Flat bracket L-bracket For communications cables, use the parts listed below (refer to the catalogue [M8/M Connector] CAT.ES-7 for details) or order the product certified for the respective protocol (with M connector) separately. Application Communication cable part number Remarks CC-Link compatibility PCA-677 (Socket type) Dedicated Bus adapter supplied PCA-6777 with the product. DeviceNet PROFIBUS DP PCA-76 (Socket type) PCA-7688 (Socket type) compatibility compatibility PCA-7646 PCA-769 T-branch connector not supplied. T-branch connector not supplied.

39 Electronic Vacuum Regulator Series ITV9/9 Standard Specifications Stepless control of vacuum pressure in proportion to an electrical signal Piping/Wiring Diagram Power supply and input signal (VDC, ma DC) VAC Vacuum pump, Ejector ITV9 OUT Tank Set pressure (Vacuum) Model Voltage Power supply Current consumption Note ) Minimum supply vacuum pressure Maximum supply vacuum pressure Set pressure range Note ) Current type Input signal Input impedance Output signal (Monitor output) Linearity Hysteresis Repeatability Sensitivity Temperature characteristics Output pressure Accuracy display Units Ambient and fluid temperature Enclosure Note 7) Weight Note 4) Voltage type Preset input Current type Voltage type Preset input Analogue output Switch output ITV9 ITV9 4 VDC % to VDC Note 6) Power supply voltage 4 VDC type:. A or less Power supply voltage to VDC type:.8 A or less Set pressure. kpa kpa. to 8 kpa 4 to ma DC, to ma DC to VDC, to VDC 4 points (Negative common), 6 points (No common polarity) Note ) Ω or less Approximately 6. kω Power supply voltage 4 VDC type: Approximately 4.7 kω Power supply voltage VDC type: Approximately. kω to VDC (Output impedance: Approximately kω) 4 to ma DC (Sink type) (Load impedance: Ω or less) Output accuracy within ±6% (Full span) NPN open collector output: Max. V, 8 ma PNP open collector output: Max. 8 ma Within ±% (Full span) Within % (Full span) Within ±% (Full span) Within.% (Full span) Within ±.% (Full span)/c ±%F.S. ± digit kpa Note ) Minimum display: to C (No condensation) IP6 g Note ) The minimum supply vacuum pressure should be. kpa less than the maximum vacuum pressure setting value. Note ) 4 to ma DC is not possible with the -wire type. Power supply voltage (4 VDC or to VDC) is required. Note ) Value for the state with no over current circuit included. If an allowance is provided for an over current circuit, the input impedance varies depending on the input power supply. This is Ω or less for an input current of ma DC. Note 4) When measuring ITV analogue output from to VDC, if the load impedance is less than kω, the analogue output monitor accuracy of within ±6% (full span) may not be available. The product with the accuracy of within ±6% is supplied upon your request. Output pressure remains unaffected. Note ) Please contact SMC regarding indication with other units of pressure. Note 6) For communication models, the maximum current consumption is.6 A or less. Note 7) For communication models, add roughly 8 g to the weight ( g for the PROFIBUS DP). Communication Specifications (CC, DE, PR, RC) Model Protocol Version Note ) Communication speed Configulation file Note ) I/O occupation area (input/output data) Communication data resolution Fail safe Terminating resistor ITV -CC CC-Link Ver. 6 k/6 k. M/ M/ M bps 4 word/4 word, bit/ bit (per station, remote device station) bit (496 resolution) HOLD Note ) /CLEAR (Switch setting) ITV -DE DeviceNet Volume (Edition.8), Volume (edition.) EDS 6 bit/6 bit bit (496 resolution) Note ) Note that version information is subject to change. Note ) Configulation files can be downloaded from the SMC's website: Note ) The output HOLD value when a CC-Link communications error occurs can be set based on the bit area data. k/ k/ k bps HOLD/CLEAR (Switch setting) ITV -PR PROFIBUS DP DP-V 9.6 k/9. k/4.4 k 9.7 k/87. k/ k. M/ M/6 M/ M bps GSD 6 bit/6 bit bit (496 resolution) CLEAR Built into the product (Switch setting) ITV -RC RS-C 9.6 kbps bit (4 resolution) HOLD 6

40 Series ITV9 Working Principle Working Principle Power supply Input signal q Vacuum pressure solenoid r Diaphragm Pressure display i Control circuit Output signal w Atmospheric pressure solenoid Atmospheric pressure u Pressure sensor e Pilot chamber When the input signal increases, the vacuum pressure solenoid q turns ON, and the atmospheric pressure solenoid w turns OFF. Because of this, VAC. and the pilot chamber e are connected, the pressure in the pilot chamber e becomes negative and acts on the top of the diaphragm r. As a result, the vacuum pressure t which is linked to the diaphragm r opens, VAC. and OUT. are connected, and the set pressure becomes negative. This negative pressure feeds back to the control circuit i via the pressure sensor u. Then, a correct operation works until a vacuum pressure proportional to the input signal is reached, and a vacuum pressure is obtained which is always proportional to the input signal. Block Diagram VAC. (Vacuum pump, etc.) ATM (Atmospheric pressure) t Vacuum pressure OUT. (Set pressure) y Atmospheric pressure Input signal + t Control circuit q Vacuum pressure solenoid w Atmospheric pressure solenoid VAC. u Pressure sensor r Diaphragm Pilot Set pressure Series ITV9 Linearity Hysteresis Repeatability. Output pressure [kpa] 4 6 Output deviation factor [% F.S.] Return Out Output deviation factor [% F.S.] 8. 7 Pressure Characteristics Output deviation factor [% F.S.] Set point Input signal [% F.S.] Set pressure: kpa Input signal [% F.S.] Count Flow Characteristics Set pressure [kpa] Supply vacuum pressure: kpa Flow characteristics measurement conditions Exhaust flow rate of the vacuum pump used for measurement: l/min (ANR) Inlet vacuum pressure: kpa (When outlet flow rate is l/min (ANR)) Maximum flow rate: l/min (ANR) (With inlet vacuum pressure at 9 kpa) VAC. side pressure (Supply pressure) (kpa) 9 Flow rate (l /min(anr))

41 Electronic Vacuum Regulator Series ITV9 Dimensions ITV9 Flat bracket. M x Connector M x.8 Breathing hole Rc /4 VAC. port () Right angle type (4-wire) Cable connector m Straight type (4-wire) Cable connector m () 84 4 x ø7 Mounting hole 4 99 () VAC. (Vacuum pressure) 9 ATM. (Atmospheric pressure) OUT (Set pressure) x Rc /4 ATM. port, OUT port Flat bracket assembly KT-ITV-F (Option). 6 4 x M x.8 thread depth 6 mm through.6 Note) Do not attempt to rotate the cable connector, as it does not turn. L-bracket 4 x R L-bracket assembly KT-ITV-L (Option) (8.) 8

Electro-Pneumatic Regulator Electronic Vacuum Regulator

Electro-Pneumatic Regulator Electronic Vacuum Regulator Electro-Pneumatic Regulator Electronic Vacuum Regulator New Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to Series ITV//! Reduced wiring

More information

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold Compact Electro-Pneumatic Regulator Series ITV How to Order For single unit and single unit for manifold ITV N Q Pressure range. MPa MPa.9 MPa Power supply voltage 4 VDC ±% to VDC Cable connector N S L

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators

More information

Series ITV1000/2000/3000

Series ITV1000/2000/3000 Electro-Pneumatic Regulator Series ITV// How to Order [Option] RoHS ITV S Model type type type Pressure range 5 MPa MPa.9 MPa CE compliant Nil Q CE compliant Note) Refer to pages, 5, and 6 for information

More information

Electro-Pneumatic Regulator/Electronic Vacuum Regulator

Electro-Pneumatic Regulator/Electronic Vacuum Regulator Electro-Pneumatic Regulator/Electronic Vacuum Regulator Series Stepless control of air pressure proportional to an electrical signal // series are compatible with various input specifications, including

More information

4 Note 1) Value for communications type. (PROFIBUS DP)

4 Note 1) Value for communications type. (PROFIBUS DP) Electro-Pneumatic Regulator/Electronic Vacuum Regulator Series Stepless control of air pressure proportional to an electrical signal Series // are compatible with various input specifications, including

More information

Thread type to 0.8 MPa to 0.8 MPa. Note) Air operated type is model IR2120 only. Note) Air operated type is model IR3120 only.

Thread type to 0.8 MPa to 0.8 MPa. Note) Air operated type is model IR2120 only. Note) Air operated type is model IR3120 only. Precision Regulator Series IR//3 5 Precision Regulator Series IR//3 Features Precise air pressure regulator for instrument applications. Three body sizes available. Pressure unaffected by supply pressure

More information

Compact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M

Compact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M Compact Vacuum Regulator Series ITV RoHS For single unit and single unit for manifold ITV Pressure range kpa Power supply voltage 4 VDC ±% to VDC How to Order N Cable connector N Without cable connector

More information

How to Order ITV N. Nil. EXHc. Base type. Nil. ø1/4"

How to Order ITV N. Nil. EXHc. Base type. Nil. ø1/4 Compact Electro-Pneumatic Regulator Series ITV RoHS How to Order [Option] For single unit and single unit for manifold ITV N Pressure range. MPa. MPa.9 MPa Power supply voltage 4 VDC ±% to VDC Cable connector

More information

Electro-Pneumatic Regulator / Electronic Vacuum Regulator

Electro-Pneumatic Regulator / Electronic Vacuum Regulator Electro-Pneumatic Regulator / Electronic Vacuum Regulator Series Series Model Regulating pressure range Port size Page Series With a simplified high-density circuit board design, an extremely compact size

More information

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL SMC REULATOR Electro-pneumatic Regulator Electronic Vacuum Regulator Series Series Series Model Regulating pressure range Port size With a simplified high-density circuit board design, an extremely compact

More information

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL SMC REULATOR ITV2 Electro-pneumatic Regulator Electronic Vacuum Regulator Series ITV Series ITV Series Model Regulating pressure range Port size With a simplified high-density circuit board design, an

More information

Series ITV009. Compact Vacuum Regulator ITV IITV00 02 n. RoHS. How to Order

Series ITV009. Compact Vacuum Regulator ITV IITV00 02 n. RoHS. How to Order Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (8) 6-8 www.cmafh.com 7 For single unit and single unit for manifold ITV 9 Pressure range 9 kpa Built-in One-touch

More information

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL Compact Electro-pneumatic Regulator Series For single unit and single unit for manifold Pressure range 9 Option. MPa. MPa.9 MPa kpa Option How to Order N Power supply voltage 24 VDC ±% 2 to VDC Option

More information

Electro-Pneumatic Regulator. Standard Specifications. Minimum supply pressure Maximum supply pressure Regulating pressure range

Electro-Pneumatic Regulator. Standard Specifications. Minimum supply pressure Maximum supply pressure Regulating pressure range 000 Electro-Pneumatic Regulator Series 000/000 Standard Specifications Symbol Straight type Right angle type Model Minimum supply pressure Maximum supply pressure Regulating pressure range Voltage Power

More information

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa 5.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator X Series This product is only for blowing gas. This product does not have sufficient pressure control for other applications (driving,

More information

Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0.

Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0. 000 Electro-Pneumatic Regulator Electronic Vacuum Regulator Series Series Model Set pressure range Port size Page Series 000 Controls air pressure steplessly in proportion to an electric signal. 0 05 to

More information

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)*

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)* 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator ITVH Series ARJ RoHS Maximum supply pressure Set pressure range Stability 3.0 MPa 0.2 to 2.0 MPa ARX AMR Stepless control of air

More information

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant -Colour Display Digital Pressure Switch Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor parts: Stainless steel 6 Fitting parts: Stainless steel 4 The sensor and fitting parts can

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions -Color Display Digital Pressure Switch /75/75H Series NPN/PNP open collector outputs added. Zero-cut off display function added. For General Fluids For Air Rated Pressure Metal Body Type 0 5 (E75) () -Color

More information

Series 10-ZSE40A(F)/10-ISE40A

Series 10-ZSE40A(F)/10-ISE40A Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High Precision Digital Pressure Switch How to Order For positive pressure Clean series For vacuum/ compound pressure 01 N01 W1 10 Rated pressure range ISEA

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Settings can be copied to up to 1 slave sensors at once. The settings of the master sensor can be copied to the slave sensors. Reduced setting efforts

More information

Pressure Control Equipment

Pressure Control Equipment Control High-pressure Precision General Purpose Special Fluid/Deionized Water (Pure Water) Detection Control Control (General purpose, high-pressure, precision, vacuum, special fluid, deionized water (pure

More information

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch Series ZSE3A(F)/ISE3A RoHS Can copy to up to 1 switches simultaneously. The settings of the master sensor can be copied to the slave sensors. Reducing

More information

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A 2-Color Display High-Precision Digital Pressure Switch Series ZSEA(F)/ISEA New M8 connector type RoHS IP65 Applicable fluid Air, Non-corrosive gas, Non-flammable gas Can copy to up to 10 switches simultaneously.

More information

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series)

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series) 3-Screen Display High-Precision Digital Pressure Switch New Added Variations! For general fluids IP65 2 outputs Analog output Setting is possible while checking Main screen the measured value. Sub screen

More information

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example E-P HYREG VY Series This hybrid regulator combines a regulator and a solenoid valve. Stepless control through electric signals Port sizes M5 to inches can be covered by combining an ultra-compact electro-pneumatic

More information

E22 Proportional Technology

E22 Proportional Technology E22 Proportional www.numatics.com Pressure Control: E22 Proportional E22 Series Unlike SENTRONIC valves, E-Series valves operate with pulsed pilot valves which change the pressure in a control chamber.

More information

Digital display Pressure range ON/OFF output Linear output Model

Digital display Pressure range ON/OFF output Linear output Model Slim Digital Pressure Sensor E8CB/ CSM_E8CB DS_E 1 with Built-in Microcomputer and Digital Display Withstands a of 9 kpa and highly reliable. Incorporates a two-turn adjuster ensuring easy setting. Be

More information

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor 2-Color Display High-Precision Digital Pressure Switch ZSE ISE RoHS ZSE ISE IP65 ZSE40 ISE40 M8 connector type ZSE10 ISE10 ISE70 ZSE80 ISE80 PS ISA3 ISA2 ISE35 Applicable Air, Non-corrosive gas, Non-flammable

More information

Fieldbus System (Output device for driving 5 port solenoid valves)

Fieldbus System (Output device for driving 5 port solenoid valves) Fieldbus System (Output device for driving port solenoid valves) New Compact 8mm (ctual size) Space-saving Installation IP67 RoHS EtherNet/IP added! For units with D-sub connector, and when connected to

More information

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth!

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth! Digital Pressure Switch Series ZSE1(F)/ISE1 Low profile 26.1mm 9.8 mm 13.5 mm 53.4 mm Reduced in depth! (Actual size) RoHScompliant Vertical mounting space reduced to approx.! 1 2 Position Detection Switch

More information

Gateway Type Serial Transmission System

Gateway Type Serial Transmission System P99-EX-B Gateway Type Serial Transmission System P Maximum 8 point control (64 inputs/64 outputs) P Flexibility of manifold valve installation improved with 4 branch wiring Flexible installation and removal

More information

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE High Precision, 2-color Display Digital Pressure Switch Series SE30/ISE30 SE ISE PSE I SE3 PS I SE 1 2 SP ISA2 IS SM PF2 IF Data With One-touch fittings are newly introduced. Straight type Elbow type 16-2-1

More information

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control Port Electro-Pneumatic Proportional Valve Series 000/000 Capable of actuating a cylinder and performing analog control of pressurization alone can be used to switch and actuate a cylinder and to perform

More information

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2 Series -PSE3 RoHS Remote Type 2-Color Display Digital Pressure Sensor Controller How to Order 2 3 4 5 Nil Options/Part No. L Input/Output specifications NPN2 output to 5 V output NPN2 output 4 to 2 m output

More information

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),

More information

Ionizer. Discharge time: 0.3 seconds. Series IZS31. Ion balance control by an autobalance sensor CAT.EUS100-68A-UK. Without sensor.

Ionizer. Discharge time: 0.3 seconds. Series IZS31. Ion balance control by an autobalance sensor CAT.EUS100-68A-UK. Without sensor. Ionizer 2 types of sensors are available. Rapid elimination of static electricity by a feedback sensor Continuously emits ions in accordance with the detected polarity of a workpiece. Supply pressure:

More information

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control Port Electro-Pneumatic Proportional Valve Series VER000/000 Capable of actuating a cylinder and performing analog control of pressurization VER alone can be used to switch and actuate a cylinder and to

More information

Model Pressure range ON/OFF output Linear output

Model Pressure range ON/OFF output Linear output Digital Sensor Sensor with Easy-to-Read LED Display status can be checked at a glance from the red digital pressure value and analog bar displays. Measurement pressure is averaged by the chattering prevention

More information

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1 Compact Flow Rate Sensor RAPIFLOW Resin Body Type Diversified High Performance High performance User-friendly Compatible CC-1235A 1 Diversified Five types of gases can be measured with just one unit Gas

More information

Ionizer (Nozzle type) Series IZN10

Ionizer (Nozzle type) Series IZN10 262 Series IZN0 / Nozzle type (Nozzle type) Series IZN0 RoHS Slim and compact: 6mm thickness. Nozzle selectable: Energy saving, large flow types and female threads for piping. ±0V ion balance: High frequency

More information

Electro-pneumatic Proportional Valve. Specifications. Model Flow type Pressure type VEF2121

Electro-pneumatic Proportional Valve. Specifications. Model Flow type Pressure type VEF2121 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 6-580 www.cmafh.com VEF Port Port Applicable power Body size Body size Electro-pneumatic Proportional

More information

Compact Proportional Solenoid Valve

Compact Proportional Solenoid Valve Compact Proportional Solenoid Valve Series Repeatability: % or less Hysteresis:1% or less Fluid Flow rate control range Note) Series Air, Inert gas to L/min to L/min Note) Varies depending on the model.

More information

Series IZS31. RoHS compliant

Series IZS31. RoHS compliant Ionizer 3 types of the sensors are available. Autobalance sensor [High-precision type] Adjusts ion balance near the workpiece to reduce any interference! New Autobalance sensor [Body-mounting type] Rapid

More information

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch -Color Display Digital Pressure Switch (F)/(H) Series Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor unit: Stainless steel 630 Fitting parts: Stainless steel 304 The sensor unit

More information

ISE7 /7 G Series CAT.ES B. MPa/1.6 MPa 1.0. MPa/2.0 MPa. MPa/10 MPa

ISE7 /7 G Series CAT.ES B. MPa/1.6 MPa 1.0. MPa/2.0 MPa. MPa/10 MPa 3-Screen Display High-Precision Digital Pressure Switch Air General Fluids 1.0 ISE70 ISE71 MPa/1.6 MPa 1.0 ISE70G ISE75G MPa/2.0 MPa 5.0 ISE76G ISE77G MPa/10 MPa It is possible to change the settings while

More information

Related vacuum products

Related vacuum products Vacuum component C O N T E N T S variation 420 Position locking valve () 422 Compact vacuum regulator () 426 Vacuum break unit () 436 Vacuum filter large volume union type (VSFB) 440 Compact vacuum filter

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Series ZSE3/ISE3 2-color digital display allows you to choose the setting according to your application requirements. 4 different display settings

More information

Non-Contact Sensor for Workpiece Placement Verification

Non-Contact Sensor for Workpiece Placement Verification ir Catch Sensor Series 2 Non-Contact Sensor for Workpiece Placement Verification Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact

More information

2 Window comparator mode. Hysteresis Hysteresis

2 Window comparator mode. Hysteresis Hysteresis SERIES High-performance Digital Pressure Sensor Digital Automatic sensitivity setting With analog output Complete functionality! Selection from a wide lineup DP3 * UL 61010C-1 compatible, Passed the UL

More information

Model Pressure range ON/OFF output Linear output

Model Pressure range ON/OFF output Linear output Authorised Distributors:- ASH & ALAIN INDIA PV LD S-1, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-112(India) el : 11-43797575 Fax : 11-43797574 E-mail : sales@ashalain.com Digital Sensor Sensor

More information

Sentronic LP IO-Link CLASS A 617 Series. Proportional Technology

Sentronic LP IO-Link CLASS A 617 Series. Proportional Technology Sentronic LP IO-Link CLASS A 617 Series Proportional Technology PROPORTIONAL PRESSURE CONTROL: 617 SERIES SENTRONIC LP IO-LINK VERSION ASCO NUMATICS Sentronic LP The Sentronic LP is a highly efficient

More information

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits SERIES LED Display Digital Pressure Sensor PE DP-M DP-Y DP3 High Accuracy High Resolution High Speed It achieves a 2.5ms, or less, response time at a high resolution of 1/1,000. It enables highly accurate

More information

EV2100V Series OUT VAC EV2100V. Specifications. 196kPa 196kPa Control pressure range Assured pressure range Power voltage Current consumption

EV2100V Series OUT VAC EV2100V. Specifications. 196kPa 196kPa Control pressure range Assured pressure range Power voltage Current consumption pneumatic regulator (solenoid type for vacuum) EVV Series JIS symbol EVV CAD DATA AVAILABLE. How to order Overview For electro pneumatic regulator EVV series, feedback control with semiconductor pressure

More information

Electro-Pneumatic Devices Valves and Positioners. The Drive & Control Company

Electro-Pneumatic Devices Valves and Positioners. The Drive & Control Company Electro-Pneumatic Devices Valves and Positioners The Drive & Control Company Electro-Pneumatic Devices Dynamic precision from Rexroth Why choose Rexroth E/P s? Rexroth electro-pneumatic pressure control

More information

Electronic Pressure Switches

Electronic Pressure Switches 96 Pressure Switches Electronic Pressure Switches Electronic E.5 switching output Electronic pressure switches, High-Performance series with one switching output Outstanding overpressure protection (up

More information

SentronicPLUS IO-Link CLASS A Electronic Pressure Regulator. Installation Manual

SentronicPLUS IO-Link CLASS A Electronic Pressure Regulator. Installation Manual SentronicPLUS IO-Link CLASS A Electronic Pressure Regulator Installation Manual Sentronic PLUS ASCO NUMATICS Sentronic PLUS Electronic Pressure Regulator Sentronic PLUS is a 3-way proportional valve with

More information

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch -Color Display Digital Pressure Switch Series ZSE80(F)/ISE80(H) Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor parts: Stainless steel 630 Fitting parts: Stainless steel 304 The

More information

SMC guide to ATEX compliant products

SMC guide to ATEX compliant products SMC guide to ATEX compliant products P-E13-23A A ATEX Directive Directive 94/9/EC Equipment and Protective Systems intended for use in potentially Explosive Atmospheres Outline of ATEX directive Since

More information

Power Valve Precision Regulator

Power Valve Precision Regulator Power Valve Precision Regulator VEX Series High precision, large capacity relief regulator port large exhaust capacity pressure reducing valve which utilizes a nozzle flapper mechanism available as air

More information

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure High Precision, Series SE30/ISE30 How Order Option 1 Without lead wire Lead wire with connecr (Lead wire length: 2 m) L For positive pressure For vacuum/low pressure ISE30 01 SE30 01 25 M 25 M 01 R 1/8

More information

VAS VAS VACUUM SWITCH SPECIFICATIONS. DIMENSIONS (mm)

VAS VAS VACUUM SWITCH SPECIFICATIONS. DIMENSIONS (mm) VACUUM SWITCHES VAS VACUUM SWITCH Diaphragm vacuum switch Compact size Lightweight Inch port sizes 5/32, 1/4 & 5/16 Metric port sizes 4, 6 & 8mm Fully adjustable VAS 10 06 Series Body Size 10 Vacuum Port

More information

AirLINE and AirLINE Quick electrical/pneumatic Automation System

AirLINE and AirLINE Quick electrical/pneumatic Automation System AirLINE and AirLINE Quick electrical/pneumatic Automation System Type 8644 can be combined with Fully compatible with Rockwell Combination of Fieldbus, pilot valves and I/O modules higher fl exibility

More information

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT Compact Manometer Pressure measurements can easily be taken any time, anywhere. RoHS Compact and lightweight Portable type with a lightweight of only about 00 g (unit 50 g, battery 50 g) can also be held

More information

Vacuum pump system type

Vacuum pump system type type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated

More information

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES 76 ORDER GUIDE DP / configuration diagram Intermediate cable s Type Vacuum pressure Positive pressure Compound pressure Appearance An intermediate cable is required to connect the controller and the sensor

More information

SV1000/2000/3000/4000

SV1000/2000/3000/4000 Decentralized Serial Wiring (GW System, Branches) Series EX00 Valve manifold and input unit manifold can be connected around the GW unit. ompatible with various protocols by replacing the GW unit. ompatible

More information

EV2000 Series. Specifications. Descriptions Working fluid Max. working pressure Min. working pressure Withstanding pressure

EV2000 Series. Specifications. Descriptions Working fluid Max. working pressure Min. working pressure Withstanding pressure (solenoid valve type medium flow) High precision air pressure proportional enabling ultimate space saving of device. nic sensor Pressure JIS symbol Overview In this electro, feedback control with semiconductor

More information

Modular pneumatic valve unit

Modular pneumatic valve unit Modular pneumatic valve unit Compact design Modular configuration High flexibility Type 8640 can be combined with Simple exchange of valves (with option P-shut-off - also possible during operation) Type

More information

Sentronic PLUS 614 Series

Sentronic PLUS 614 Series Sentronic PLUS 64 Series Proportional Technology www.asco.com PRESSURE CONTROL: 64 SERIES SENTRONIC PLUS Sentronic PLUS Sentronic PLUS is a digitally operated pressure regulator valve. This valve accurately

More information

25% reduction in volume * PB1013A/Air-operated type without foot

25% reduction in volume * PB1013A/Air-operated type without foot Process Pump (Diaphragm Pump) Series Compact, large capacity diaphragm pump, suitable for transferring and collecting a wide range of fluids Smaller, lighter, lmtop size Pa 5% reduction in volume * 11A/Air-operated

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions Series ISE70/75/75H NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. For General Fluids For Air 2-Color Display (Green/Red) Selectable from four patterns ON Red Green Red Green

More information

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits SERIES LED Display Digital Pressure Sensor Complete Functionality from a Wide Model Line-up Marked Conforming to EMC Directive High Accuracy High Resolution High Speed It achieves a 2.5ms, or less, response

More information

Electronic Pressure Switches

Electronic Pressure Switches 96 Pressure Switches Electronic Pressure Switches Electronic E.6 2 switching outputs Electronic pressure switches, High-Performance series with two switching outputs Outstanding overpressure protection

More information

Vacuum Equipment. Application. Series

Vacuum Equipment. Application. Series Equipment Series Application Page ejector In-line vacuum ejector Multistage ejector ejector with check valve Pad with check valve ejector for water soluble coolant removal ZH ZU ZL1/2 (Special order product)

More information

New Concept Connector Type Manifold

New Concept Connector Type Manifold New Concept Connector Type Manifold Series /000/3000/000 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration.

More information

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle. Multistage Ejector 112/212 Series Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type Series ISE70/75/75H New NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. For General Fluids For Air 2-Color Display (Green/Red) Selectable from four patterns ON Red Green Red

More information

Series AV2000/3000/4000/5000

Series AV2000/3000/4000/5000 Soft Start-up Valve Series AV/3/4/5 Series introduced! A start-up valve that gradually increases supply pressure during start up and rapidly exhausts system air when the supply air is shut off AC AV AU

More information

VQ1000. How to Order Manifold. Kit type

VQ1000. How to Order Manifold. Kit type - - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold

More information

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications Series -SQ00 Port Solenoid Valve Plug-in Unit [Option] How to Order Manifold Electrical entry F kit D-sub connector kit P kit SSQ 08 FD Kit type Flat ribbon cable connector kit J kit Flat ribbon cable

More information

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System Remote Process Actuation Control System AirLINE - Rockwell 1734 Type 8644 can be combined with... Fully compatible with Rockwell 1734 Point I/O System Combination of Fieldbus, pilot valves and I/O modules

More information

Remote Process Actuation Control System AirLINE WAGO Remote I/Os and Fieldbusses

Remote Process Actuation Control System AirLINE WAGO Remote I/Os and Fieldbusses Remote Process Actuation Control System AirLINE WAGO Remote I/Os and Fieldbusses Type 8644 can be combined with... Fully compatible with WAGO I/O Combination of Fieldbus, pilot valves and I/O modules High

More information

Table of Contents. Proportional & Precision Regulator Instrumentation

Table of Contents. Proportional & Precision Regulator Instrumentation Table of Contents Proportional & Precision Regulator Instrumentation...3-27 Features and Benefits... 3 Electropneumatic Transducer...4-5 Economy Miniature Electropneumatic Transducer...6-7 Miniature Electropneumatic

More information

Series PSE560 Pressure Sensor For General Fluids... 90

Series PSE560 Pressure Sensor For General Fluids... 90 Table of Contents Pressure Switch Selection Guide... Electronic Pressure Switch... Mechanical Pressure... Pressure Switch Application Example... Series SE/ISE High Precision, 2-color Display Digital Pressure

More information

Intelligent Positioner

Intelligent Positioner Intelligent Positioner Construction The GEMÜ 1 µpos is a digital electro-pneumatic positioner for process valve control. Designed for simple, safe and quick use with valves with strokes < mm. The positioner,

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

Air Catch Sensor. Non-Contact Sensor for Workpiece Placement Confirmation

Air Catch Sensor. Non-Contact Sensor for Workpiece Placement Confirmation Air Catch Sensor Non-Contact Sensor for Workpiece Placement Confirmation Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact type

More information

Remote Type Pressure Sensors Pressure Sensor Controllers

Remote Type Pressure Sensors Pressure Sensor Controllers CT.EUS1-56B-UK Remote Type Pressure Sensors Pressure Sensor Controllers Compact Pressure Sensor for Pneumatics PSE53 Multi-channel Digital Pressure Sensor Controller PSE2 Compact Pressure Sensor for Pneumatics

More information

Compact Vacuum Ejector

Compact Vacuum Ejector Compact acuum Ejector Series ZA Total length Total width 7.9 mm 9.9 mm Total height. mm Response time 0 ms Response time for up to 0 ka Nozzle diameter: ø0.7 iping: ø/ø. x 0 mm Able to install on the moving

More information

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000

More information

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch -Color Display Digital Pressure Switch Series ZSE80(F)/ISE80(H) Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor parts: Stainless steel 630 Fitting parts: Stainless steel 304 The

More information

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer Base Mounted Metal Seal/Rubber Seal VQ Built-in silencer, direct exhaust Space-saving profile All pilot valves are compactly mounted on one side. The space-saving design of mounting all fittings on one

More information

2-Color Display Digital Flow Switch

2-Color Display Digital Flow Switch -Color Display Digital Flow Switch Series Flow rate range:, 5, 5, l/min. Minimum unit setting:. l/min. (. l/min when the flow rate range is 5, 5, l/min.) Repeatability: ±%F.S. or less Grease-free Flow

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

We're everywhere you need us to be! Valves. OBSOLETE PRODUCT Check availability. on Proportional Regulator E22 Series

We're everywhere you need us to be! Valves. OBSOLETE PRODUCT Check availability. on  Proportional Regulator E22 Series We're everywhere you need us to be! Proportional Regulator E22 Series Pneumatic-Catalogue-GB-09/05 659 General Informationen The E22 Series electronic proportional regulator quickly and accurately adjusts

More information

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features. Data sheet 405052 Page 1/10 JUMO DELOS SI Precision pressure transmitter with switching contacts and display Application Food & pharma CIP/SIP systems Machine and system construction Air conditioning and

More information