How to Order Single Unit 25A-ZK2 A 12 N 0 N N 08. e Combination of supply valve Note 3) and release valve. Note 5) K

Size: px
Start display at page:

Download "How to Order Single Unit 25A-ZK2 A 12 N 0 N N 08. e Combination of supply valve Note 3) and release valve. Note 5) K"

Transcription

1 Vacuum Unit RoHS Series 25-ZK2 How to Order Single Unit Ejector System (with Valve) Ejector System (without Valve) 25-ZK2 12 K ZK q w e r t y u i Remains blank when option is not selected. q System/ody type System ody type Exhaust type Silencer exhaust uilt-in silencer e Combination of supply valve and release valve Supply valve Release valve ote 5) K.C..C. Supply valve Release valve J.C. Ejector system Single unit Port exhaust ote 1) R Self-holding release valve linked ote 4).C. High-noise reduction silencer exhaut ote 1) Port size of exhaust port: ø8 (Metric) With silencer Only non-locking type is available for the manual override for K, J, R. ote 4) Self-holding type maintains vacuum by instantaneous energization (20 ms or more). Stopping the vacuum turns on the release valve. (signal to stop vacuum not needed) ote 5) When the digital pressure switch for vacuum with energy saving function is selected for t, select K for e Combination of supply valve and release valve. w ominal nozzle size System ominal size Ejector system ote 2) ø0.7 ø1.0 ø1.2 ø1.5 ote 2) Standard supply pressure for nozzle size 07 to 12 is 0.35 MPa, 15 is 0.4 MPa Manifold type is not available. ote 6) r Rated voltage Voltage 5 24 VDC 6 12 VDC 0 When e is ote 6) Rated voltage for the supply and release valve t Pressure sensor/digital pressure switch for vacuum specifications Pressure range Type Specifications [kpa] P T C D E F H J K Q R S Pressure sensor Digital pressure switch for vacuum Digital pressure switch for vacuum with energy saving function ote 9) 0 to to 100 P 2 outputs 0 to 101 PP 2 outputs P 2 outputs 100 to 100 PP 2 outputs 100 to 100 nalog output 1 to 5 V nalog output 1 to 5 V P 1 output PP 1 output Unit selection function ote 7) SI unit only ote 8) Unit selection function ote 7) SI unit only ote 8) Unit selection function ote 7) SI unit only ote 8) Unit selection function ote 7) SI unit only ote 8) Unit selection function ote 7) SI unit only ote 8) Unit selection function ote 7) SI unit only ote 8) Pressure sensor Digital pressure switch for vacuum Digital pressure switch for vacuum with energy saving function Without pressure sensor/ Digital pressure switch for vacuum 115 ote 7) Unit selection function is not available in Japan due to new measurement law. ote 8) Fixed unit: kpa ote 9) When K, Q, R or S is selected, select K for e Combination of supply valve and release valve. Select W or 3 for y.

2 Vacuum Unit Series 25-ZK2 PV: ir pressure supply port/port for vacuum source (Vacuum pump) PS: Pilot pressure supply port PD: Individual release pressure supply port V: Vacuum port EXH: Exhaust port PE: Pilot pressure exhaust port Directional Control Valves y Supply valve/release valve/digital pressure switch for vacuum connector specifications efor supply valve/release valve ote 10) tead Connector type ead wire with connector wire with connector for pressure switch/ sensor ote 13) v ote 11) v ote 14) u Vacuum (V) port ote 16) Type Port size Metric size ø6 One-touch fitting ø8 One-touch fitting V ir Cylinders Related Products 1 u ote 12) v ote 14) -type plug 2 v connector ote 11) u ote 15) ote 16) Supply (PV) port size of single unit: ø6 Rotary 3 u ote 12) u ote 15) W 1 on-valve (without supply/release valve) When is selected for e With lead wire for switch with energy saving function v ote 14) When is selected for both e and t (without supply/release valve, without switch, pressure sensor) u ote 10) Solenoid valve with light/surge voltage suppressor ote 11) Standard lead wire length for solenoid valve is 300 mm. ote 12) For lead wire lengths other than standard, select 1 or 3, and order the connector assembly desired. (Refer to page 117.) ote 13) Standard lead wire length for pressure sensor is 3 m. Standard lead wire length with connector for vacuum pressure switch and the lead wire length for switch with energy saving function is 2 m. ote 14) Select, 1, when the pressure sensor (P, T) is selected for t Pressure sensor/ Digital pressure switch for vacuum specifications. Since only grommet type is available for the pressure sensor, sensor without lead wire cannot be selected. ote 15) Select when no vacuum pressure switch, pressure sensor, or vacuum pressure switch with connector without lead wire is used. ote 23) Single Unit and Options Vq System/ ody type Vw ominal nozzle size Ve Combination of supply valve and release valve Vr Rated voltage Vt Pressure sensor/digital pressure switch for vacuum specifications Vy Supply valve/release valve/digital pressure switch for vacuum connector specifications Vu Vacuum (V) port Vi Optional specifications P/T /1 K //C/D/E/F/H/J /1/2/3 /D/J/K/W 2/3 K/Q/R/S 3/W /D/J/K 07 5 P/T /1 // 10 R 6 //C/D/E/F/H/J /1/2/3 06 /D/J/K/W 2/3 12 P/T / J //C/D/E/F/H/J /1/2/3 /W 2/3 P/T 0 //C/D/E/F/H/J /1 /W ote 23) When J or is selected for e Combination of Supply Valve and Release Valve, D, J or K cannot be selected for i Optional Specifications/Functions/pplications. For options not in the table, please contact SMC. * Refer to the WE catalog or the est Pneumatics o. 4 when mounting single unit to DI rail. ote 17) i Optional Specifications Type Without option D J K W With one bracket for mounting a single unit (Mounting screw is attached.) With individual release pressure supply ote 18) (PD) port Vacuum break flow adjusting needle Round lock nut type Vacuum break flow adjusting needle Screwdriver operation type With exhaust interference prevention valve ote 19, 20, 21, 22) ote 17) When more than one option is selected, list the option symbols in an alphabetical order. Example) -J ote 18) Use One-touch fittings or barb fittings with O.D. ø6.2 or less for piping. (Recommended fitting: M-3U-4) ote 19) To prevent backflow of the exhaust air, not for holding vacuum. This option does not completely stop the backflow of the exhaust air. Select port exhaust type depending on purpose. ote 20) When J is selected for e Combination of supply valve and release valve and W (exhaust interference prevention valve type) is selected for i Optional specifications/functions/pplications, install a release valve or vacuum breaker. ote 21) When K, Q, R, or S is selected for t Pressure sensor/digital pressure switch for vacuum specifications, the exhaust interference prevention valve is provided. So, it is not necessary to select W. ote 22) For high-noise reduction silencer exhaust, W (With exhaust interference prevention valve) cannot be selected. * Specifications and dimensions for the 25-series are the same as standard products. 116 ir rippers Vacuum ir Preparation Clean ir Filters ir Filters/Pressure Control Fittings/Flow Control Detection Fluid Control Electric uto

3 Series 25-ZK2 Replacement Parts/How to Order Connector assembly ZK2 V W pplicable valve type Valve type K/R W (With supply valve and release valve) Valve type J S (Supply valve only) For single Red ead wire length 300 mm mm mm mm mm For double Red White ead wire with connector for vacuum pressure switch (When individual lead wire is necessary, order with the part number below.) ead wire with connector for vacuum pressure switch ZS 39 5 ead wire with connector for switch with energy saving function ZK2 W 20 Output specifications P open collector PP open collector lack lack Vacuum pressure switch assembly 25 ZK2 ZS E M w Output specifications P PP q w e r q Rated pressure range and function E 0 to 101 kpa Vacuum pressure switch Open collector 2 outputs F 100 to 100 kpa Pressure switch with V 100 to 100 kpa Open collector 1 output energy saving function e Unit specifications Unit selection function ote 1) M SI unit only ote 2) ote 1) Unit selection function is not available in Japan due to measurement law. ote 2) Fixed unit: kpa Pressure sensor assembly ZK PS 1 Rated pressure range and specifications 0 to 101 kpa, Output: 1 to 5 V, ccuracy: ±2% F.S. or less 100 to 100 kpa, Output: 1 to 5 V, ccuracy: ±2% F.S. or less High-noise reduction silencer case assembly ZK2 SC3 4 Exhaust port size 4 ø4 For nozzle size 07, 10 6 ø6 For nozzle size 12, 15 r ead wire with connector With lead wire When q is E or F For vacuum pressure switch, ead wire with connector (ength 2 m) When q is V For switch with energy saving function, ead wire with connector (ength 2 m) Optional Specifications/Functions/pplications Type Function/pplication With one bracket for mounting a single unit (Mounting screw is attached.) racket Use when a single unit is mounted to the floor in an upright position is requested. (The part number for ordering only a bracket is 25-ZK2-K1-. olt nuts are included.) D With individual release pressure supply (PD) port PD port Use when supply pressure for vacuum release which pressure is different from the ejector supply pressure is requested. J Vacuum break flow adjusting needle Round lock nut type Vacuum break flow adjusting needle Thicker than standard hexagon type. More suitable for hand tightening. Round lock nut improves operability when manifold, pump system, or exhaust port type is used. K Vacuum break flow adjusting needle Screwdriver operation type Vacuum break flow adjusting needle Slotted type improves fine adjustment performance when manifold, pump system, or exhaust port type is used. W 117 With exhaust interference prevention valve Exhaust interference prevention valve When ejectors are operated individually, exhausted air may flow backward from the V port of ejectors that are turned off. Exhaust interference prevention valve prevents backflow.

4 uto Electric Fluid Control Detection Fittings/Flow Control ir Filters/Pressure Control Clean ir Filters ir Preparation Vacuum ir rippers Rotary Related Products ir Cylinders Directional Control Valves 118

5 Space Saving Vacuum Ejector Series 25-ZQ [Option] ote) CE-compliant: For DC only. How to Order Ejector Unit 25 ZQ1 05 1U K1 5 E q w e r t y u i o!0!1!2!3!4 Series compatible with secondary batteries q ozzle nominal size w Exhaust type ø0.5 ø0.7 ø1.0 1U 3M With silencer for single unit With silencer for manifold e Solenoid valve combination (Refer to Table (1).) K1 ote 1) K2 J1 ote 1) J2 Q1 Q2 1 2 Table (1) Combination of Solenoid Valve, Pilot Valve and Power Supply Voltage Combination no. q w e r t y u i o!0 Supply valve ormally open ormally open atching positive common atching positive common atching negative common atching negative common Solenoid valve combination symbol K1 K1 K2 J1 J1 J2 Q1 Q2 1 2 Pilot valve symbol Vacuum release valve ote 1) In cases when K2 or J2 (supply valve normally open) is selected for the solenoid valve combination, when vacuum is stopped for long periods of time (10 minutes or more), do not continue to energize the supply valve, and shut off the air supply. 100 C pplicable power supply voltage (V) 200 C r Pilot valve (Refer to Table (1).) 110 C Combinations q to!0 in the above table are the only possible options. ote 2) Standard (DC: 1 W) ote 2) DC low wattage type (0.5 W) ote 2) void energizing the solenoid valve for long periods of time. (Refer to Design and Selection on Specific Product Precautions.) 220 C 24 DC 12 DC t Solenoid valve rated voltage (Refer to Table (1).) VC (50/60 Hz) 200 VC (50/60 Hz) 110 VC (50/60 Hz) 220 VC (50/60 Hz) 24 VDC 12 VDC CE-compliant CE-compliant products are not available for 1, 2, 3 and

6 Space Saving Vacuum Ejector Series 25-ZQ y Electrical entry O -type plug connector, with 0.3 m lead wire, with light/surge voltage suppressor -type plug connector, without connector, with light/surge voltage suppressor ote 4) u Manual override Directional Control Valves on-locking push type atching type: Push-locking type ocking type (Q1/Q2/1/2: ot applicable) ote 4) atching type supply valve: vailable in only. In this case, the supply valve and release valve come with a push-locking type. ir Cylinders Related Products Rotary rommet, with 0.3 m lead wire (atching/c type: ot applicable) ir rippers ote 5) i Vacuum pressure switch suction filter E E EC EE F F FC FE F 0 to 101 kpa/p open collector 2 outputs, with suction filter 0 to 101 kpa/pp open collector 2 outputs, with suction filter 0 to 101 kpa/p open collector 1 output + analog voltage, with suction filter 0 to 101 kpa/pp open collector 1 output + analog voltage, with suction filter 100 to 100 kpa/p open collector 2 outputs, with suction filter 100 to 100 kpa/pp open collector 2 outputs, with suction filter 100 to 100 kpa/p open collector 1 output + analog voltage, with suction filter 100 to 100 kpa/pp open collector 1 output + analog voltage, with suction filter Suction filter only ote 5) The filter included in this product is of an simple type, and will become clogged quickly in environments with high quantities of dust or particulates. Please make additional use of an air suction filter of the ZF, ZF or ZFC series. Warning The filter case of this suction filter is made of nylon. Contact with alcohol or similar chemicals may cause it to be damaged. lso, do not use the filter when these chemicals are present in the atmosphere. ote 8)!1 Check valve K With check valve ote 8) The check valve has a function to prevent the exhaust air from the silencer overflowing to the vacuum port side when a manifold is used. However, depending on usage conditions, it does not always suppress air overflow to the desired extent. During usage, please inspect thoroughly with actual machine. lso, in order to completely prevent the overflow of exhaust air, leave plenty of space between the check valve unit and adjacent ejector to avoid interference from the ejector s exhaust unit. Warning q Cannot be used for vacuum retention. w Use a release valve. (Without a release valve, a workpiece may not be released.)!2 Fitting (V port) 0!3 Fitting (P port) 0 pplicable tubing O.D. Without fitting (M5 x 0.8) pplicable tubing O.D. Object spec. Without port Manifold Without fitting (M5 x 0.8) Single unit o Vacuum pressure switch unit specifications!0 Vacuum pressure switch lead wire specifications!4 CE-compliant CE-compliant Specifications and dimensions for the 25-series are the same as standard products. M P ote 6) With unit switching function ote 7) Fixed SI unit ote 6) With unit switching function (Initial value psi) ote 6) Under the ew Measurement aw, sales of switches with the unit switching function are not allowed for use in Japan. ote 7) Fixed unit: kpa Without connector ead wire with connector (ead wire length 2 m) With connector cover Q ote) CE-compliant: For DC only. 120 Vacuum ir Preparation Clean ir Filters ir Filters/Pressure Control Fittings/Flow Control Detection Fluid Control Electric uto

7 Series 25-ZQ How to Order 25 ZZQ1 07 S C Manifold umber of stations ote) 01 1 station 02 2 stations Specifications and dimensions for the 25-series are the same as standard products stations ote) umber of stations varies according to nozzle nominal size during simultaneous operation. Maximum umber of Stations in Simultaneous Operation ozzle Maximum number nominal of stations in simultaneous size operation ø0.5 8 stations ø0.7 6 stations ø1.0 4 stations ir pressure supply (P) port position oth sides S Exhaust With silencers (oth sides) Vacuum release pressure supply port (PD port) (Release pressure is supplied from the P port.) Provided C (ir can be alternatively supplied from the P port.) 121

8 Space Saving Vacuum Ejector Series 25-ZQ How to Order Solenoid valve ctuation 1 25 ZQ1-VQ ZQ1-VQ ctuation 2 ormally open Pilot valve Standard (1 W) Pilot valve Solenoid valve rated voltage 5 24 VDC 6 12 VDC Standard (DC: 1 W) DC low wattage type (0.5 W) C type: ot applicable atching positive common atching negative common Manual override ote) Solenoid valve rated voltage VC (50/60 Hz) VC (50/60 Hz) VC (50/60 Hz) VC (50/60 Hz) 5 24 VDC 6 12 VDC on-locking push type atching type: Push-locking type ocking type ote) atching type: vailable in only Electrical entry ote) -type plug connector, with 0.3 m lead wire -type plug connector, O without connector rommet, with 0.3 m lead wire (atching/c type: ot applicable) ote) Mounting screws are attached. Directional Control Valves ir Cylinders Related Products Rotary ir rippers Vacuum Vacuum pressure switch E E EC EE F F FC FE 25 ZQ1-ZS Vacuum pressure switch specifications 0 to 101 kpa/p open collector 2 outputs, with suction filter 0 to 101 kpa/pp open collector 2 outputs, with suction filter 0 to 101 kpa/p open collector 1 output + analog voltage, with suction filter 0 to 101 kpa/pp open collector 1 output + analog voltage, with suction filter 100 to 100 kpa/p open collector 2 outputs, with suction filter 100 to 100 kpa/pp open collector 2 outputs, with suction filter 100 to 100 kpa/p open collector 1 output + analog voltage, with suction filter 100 to 100 kpa/pp open collector 1 output + analog voltage, with suction filter Vacuum pressure switch unit specifications ote 1) With unit switching function ote 2) M Fixed SI unit ote 1) With unit switching function P (Initial value psi) ote 1) Under the ew Measurement aw, sales of switches with the unit switching function are not allowed for use in Japan. ote 2) Fixed unit: kpa Vacuum pressure switch lead wire specifications Without connector ead wire with connector (lead wire length 2 m) With connector cover Check valve K With check valve Fitting (V port) pplicable tubing O.D. 0 Without fitting (M5 x 0.8) The check valve has a function to prevent the exhaust air from the silencer overflowing to the vacuum port side when a manifold is used, but it is incapable of completely preventing overflow. During usage, please inspect thoroughly with actual machine. lso, in order to completely prevent the overflow of exhaust air, leave plenty of space between the check valve unit and adjacent ejector to avoid interference from the ejector s exhaust unit. Warning q Cannot be used for vacuum retention. w Use a vacuum release valve. (Without a vacuum release valve, the workpiece may not be released.) ead wire with ote connector part no. ead wire length 2 m ZS-39-5 (With connector cover) ir Preparation Clean ir Filters ir Filters/Pressure Control Fittings/Flow Control Detection Fluid Control Electric Specifications and dimensions for the 25-series are the same as standard products. uto 122

9 Space Saving Vacuum Pump System Series 25-ZQ [Option] ote) CE-compliant: For DC only. How to Order Vacuum pump unit 25 ZQ1000 U K1 5 Series compatible q w e r t y u i o!0!1!2 with secondary batteries q ody type E U M For single unit For manifold w Solenoid valve combination (Refer to Table (1).) K1 ote 1) K2 J1 ote 1) J2 Q1 Q2 1 2 Supply valve ormally open ormally open atching positive common atching positive common atching negative common atching negative common Vacuum release valve The air in the adsorption section of this product is not released to the atmosphere at the vacuum suspension state. s for K1, K2, Q1 and 1, use the vacuum release valve when a workpiece is detached. Concerning J1, J2, Q2 and 2, devise the circuit for the vacuum release additionally when a workpiece is detached. ote 1) In cases when K2 or J2 (supply valve normally open) is selected for the solenoid valve combination, when vacuum is stopped for long periods of time (10 minutes or more), do not continue to energize the supply valve, and shut off the air supply. e Pilot valve (Refer to Table (1).) r Solenoid valve rated voltage (Refer to Table (1).) ote 2) Standard (DC: 1 W) DC low wattage type (0.5 W) ote 2) VC (50/60 Hz) CE-compliant ote 2) void energizing the solenoid VC (50/60 Hz) valve for long periods of time VC (50/60 Hz) (Refer to Specific Product VC (50/60 Hz) Precautions; Caution on Design and Selection.) 5 24 VDC 6 12 VDC CE-compliant products are not available for 1, 2, 3 and 4. Table (1) Combination of Solenoid Valve, Pilot Valve and Rated Voltage Combination Solenoid valve Pilot valve no. combination symbol symbol 100 C 200 C q w e r t y u i o!0 K1 K1 K2 J1 J1 J2 Q1 Q2 1 2 Combinations q to!0 in the above table are the only possible options. 123 pplicable power supply voltage (V) 110 C 220 C 24 DC 12 DC

10 Space Saving Vacuum Pump System Series 25-ZQ t Electrical entry O -type plug connector, with 0.3 m lead wire, with light/surge voltage suppressor Directional Control Valves -type plug connector, without connector, with light/surge voltage suppressor ote 4) y Manual override on-locking push type atching type: Push-locking type ocking type (Q1/Q2/1/2: ot applicable) ote 4) atching type supply valve: vailable in only. In this case, the supply valve and release valve come with a push-locking type. ir Cylinders Related Products Rotary rommet, with 0.3 m lead wire (atching/c type: ot applicable) ir rippers ote 5) u Vacuum pressure switch suction filter E E EC EE F F FC FE F 0 to 101 kpa/p open collector 2 outputs, with suction filter 0 to 101 kpa/pp open collector 2 outputs, with suction filter 0 to 101 kpa/p open collector 1 output + analog voltage, with suction filter 0 to 101 kpa/pp open collector 1 output + analog voltage, with suction filter 100 to 100 kpa/p open collector 2 outputs, with suction filter 100 to 100 kpa/pp open collector 2 outputs, with suction filter 100 to 100 kpa/p open collector 1 output + analog voltage, with suction filter 100 to 100 kpa/pp open collector 1 output + analog voltage, with suction filter Suction filter only ote 5) The filter included in this product is of an simple type, and will become clogged quickly in environments with high quantities of dust or particulates. Please make additional use of an air suction filter of the ZF, ZF or ZFC series. Warning The filter case of this suction filter is made of nylon. Contact with alcohol or similar chemicals may cause it to be damaged. lso, do not use the filter when these chemicals are present in the atmosphere.!0 Fitting (V port) 0 ote 8) pplicable tubing O.D. Without fitting (M5 x 0.8) ote 8)!1 Fitting (PS / PV port) 0 pplicable tubing O.D. Without port Without fitting (M5 x 0.8) Part no. Object spec. Manifold Single unit i Vacuum pressure switch unit specifications M P ote 6) With unit switching function ote 7) Fixed SI unit ote 6) With unit switching function (Initial value psi) ote 6) Under the ew Measurement aw, sales of switches with the unit switching function are not allowed for use in Japan. ote 7) Fixed unit: kpa o Vacuum pressure switch lead wire specifications Without connector ead wire with connector (ead wire length 2 m) With connector cover Vacuum ir Preparation Clean ir Filters ir Filters/Pressure Control Fittings/Flow Control Detection!2 CE-compliant Q CE-compliant ote) CE-compliant: For DC only. ote 8) For filter only (Without vacuum pressure switch) When neither V port fitting nor PS/PV port fitting are needed, enter nothing or 00 in the dotted line How to Order. Fluid Control Electric Specifications and dimensions for the 25-series are the same as standard products. 124 uto

11 Series 25-ZQ How to Order 25 ZZQ station stations Manifold umber of stations 08 8 stations O Vacuum pressure supply port (PV port) Port location (Refer to Table (1).) R eft side Right side Table (1) ir Pressure Supply Port ocation on the Manifold Manifold PD port Port location (eft side) R (Right side) (eft side) C R (Right side) PS ote) eft PV PD Right PS PV ote) PD ote) The position of each port is shown as right and left sides viewed from the front side of the vacuum port. Release pressure is commonly supplied from the PS port. PS: Pilot pressure supply port, PV: Vacuum pressure supply port, PD: Release pressure supply port C Release pressure supply port (PD port) (Release pressure is supplied from the PS port.) Provided (ir can be alternatively supplied from the PS port.) Specifications and dimensions for the 25-series are the same as standard products. 125

12 Space Saving Vacuum Pump System Series 25-ZQ How to Order Solenoid valve ctuation 1 ZQ1 VQ ZQ1 VQ ctuation 2 ormally open Pilot valve Standard (1 W) Pilot valve Solenoid valve rated voltage 5 24 VDC 6 12 VDC Standard (DC: 1 W) DC low wattage type (0.5 W) C type: ot applicable atching positive common atching negative common Manual override ote) Solenoid valve rated voltage VC (50/60 Hz) VC (50/60 Hz) VC (50/60 Hz) VC (50/60 Hz) 5 24 VDC 6 12 VDC on-locking push type atching type: Push-locking type ocking type ote) atching type: vailable in only Electrical entry ote) -type plug connector, with 0.3 m lead wire -type plug connector, O without connector rommet, with 0.3 m lead wire (atching/c type: ot applicable) ote) Mounting screws are attached. Directional Control Valves ir Cylinders Related Products Rotary ir rippers Vacuum Vacuum pressure switch E E EC EE F F FC FE 25 ZQ1 ZS Vacuum pressure switch specifications 0 to 101 kpa/p open collector 2 outputs, with suction filter 0 to 101 kpa/pp open collector 2 outputs, with suction filter 0 to 101 kpa/p open collector 1 output + analog voltage, with suction filter 0 to 101 kpa/pp open collector 1 output + analog voltage, with suction filter 100 to 100 kpa/p open collector 2 outputs, with suction filter 100 to 100 kpa/pp open collector 2 outputs, with suction filter 100 to 100 kpa/p open collector 1 output + analog voltage, with suction filter 100 to 100 kpa/pp open collector 1 output + analog voltage, with suction filter Vacuum pressure switch unit specifications ote 1) With unit switching function ote 2) M Fixed SI unit ote 1) With unit switching function P (Initial value psi) ote 1) Under the ew Measurement aw, sales of switches with the unit switching function are not allowed for use in Japan. ote 2) Fixed unit: kpa Vacuum pressure switch lead wire specifications Without connector ead wire with connector (ead wire length 2 m) With connector cover Check valve K With check valve Fitting (V port) pplicable tubing O.D. 0 Without fitting (M5 x 0.8) The check valve has a function to prevent the exhaust air from the silencer overflowing to the vacuum port side when a manifold is used, but it is incapable of completely preventing overflow. During usage, please inspect thoroughly with actual machine. lso, in order to completely prevent the overflow of exhaust air, leave plenty of space between the check valve unit and adjacent ejector to avoid interference from the ejector s exhaust unit. Warning q Cannot be used for vacuum retention. w Use a vacuum release valve. (Without a vacuum release valve, the workpiece may not be released.) ead wire with ote connector part no. ead wire length 2 m ZS-39-5 (With connector cover) ir Preparation Clean ir Filters ir Filters/Pressure Control Fittings/Flow Control Detection Fluid Control Electric Specifications and dimensions for the 25-series are the same as standard products. uto 126

How to Order Single Unit 25A-ZK2 A 12 N 0 N N 08. e Combination of supply valve Note 3) and release valve. Note 5) K. Note 6)

How to Order Single Unit 25A-ZK2 A 12 N 0 N N 08. e Combination of supply valve Note 3) and release valve. Note 5) K. Note 6) Vacuum Unit RoHS Series 25A-ZK2 How to Order Single Unit Ejector System (with Valve) Ejector System (without Valve) 25A-ZK2 A 12 K 5 A 08 25A-ZK2 A 12 0 08 q w e r t y u i Remains blank when option is

More information

Space Saving Vacuum Ejector/Vacuum Pump System

Space Saving Vacuum Ejector/Vacuum Pump System Space Saving acuum Ejector/acuum ump System Series Current 21.6 mm mm Width mm [Option] Weight 9 g Single unit with vacuum pressure switch and suction filter ZK2 ZR Z Z ZM ZL -X267 ZU Ejector.2 ump System.118

More information

Specialized Product. Fieldbus-compatible Vacuum Unit. Applicable to 6 types of communication networks. Applicable to 4-station/8-station manifolds

Specialized Product. Fieldbus-compatible Vacuum Unit. Applicable to 6 types of communication networks. Applicable to 4-station/8-station manifolds Contact our sales office for delivery dates and prices as this is a special model. P.G. information Fieldbus-compatible Vacuum Unit Features Applicable to 6 types of communication networks Applicable to

More information

Space Saving Vacuum Ejector / Vacuum Pump System

Space Saving Vacuum Ejector / Vacuum Pump System CT.US0-1'-UK Space Saving acuum jector / acuum ump System Conventional ZX 21. mm mm ZQ Series ZQ Width mm Weight 9 g Single unit with vacuum pressure switch and suction filter jector ump System NW asy-to-use

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

Energy saving ejector

Energy saving ejector acuum Unit ZK2 Series acuum acuum ump RoHS Energy saving ejector Digital pressure switch for vacuum with energy saving function cuts supply air when the pressure reached the desired vacuum. ir consumption

More information

Compact Vacuum Unit. 46 g Single unit weight. New RoHS. 17% reduced 21% Ejector/Vacuum Pump System. 10 mm mm mm.

Compact Vacuum Unit. 46 g Single unit weight. New RoHS. 17% reduced 21% Ejector/Vacuum Pump System. 10 mm mm mm. Compact acuum Unit Ejector/acuum Pump System New RoHS Quick response Compact/ Lightweight Response time of the : ms acuum response time: 8 ms (Shortened by %; Comparison with other SMC products) Conditions:

More information

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle. Multistage Ejector 112/212 Series Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus

More information

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),

More information

Compact Vacuum Ejector

Compact Vacuum Ejector Compact acuum Ejector Series ZA Total length Total width 7.9 mm 9.9 mm Total height. mm Response time 0 ms Response time for up to 0 ka Nozzle diameter: ø0.7 iping: ø/ø. x 0 mm Able to install on the moving

More information

Energysaving. (10 mm) 3.09 inch (78.5 mm) Silencer (Built-in)

Energysaving. (10 mm) 3.09 inch (78.5 mm) Silencer (Built-in) Compact acuum Unit Ejector/acuum Pump System Quick response Compact/ Lightweight Response time of the : 5 ms acuum response time: 28 ms (Shortened by 25%; Comparison with other SMC products) Conditions:

More information

Compact Vacuum Unit Ejector/Vacuum Pump System. 46 g. New. 17% reduced 21% 10 mm mm mm. Series ZB. Response time of the valve: 5 ms

Compact Vacuum Unit Ejector/Vacuum Pump System. 46 g. New. 17% reduced 21% 10 mm mm mm. Series ZB. Response time of the valve: 5 ms Compact acuum Unit Ejector/acuum Pump System New RoHS Quick response Compact/ Lightweight Response time of the : ms acuum response time: 8 ms (Shortened by %; Comparison with other SMC products) Conditions:

More information

Series ZM Applications

Series ZM Applications Ejector [Option] ll in One! Built-in suction filter and silencer ir supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)

More information

Vacuum / Release Unit

Vacuum / Release Unit Rubber Seal Vacuum / Release Unit Series VQD1000-V Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area Smooth detachment of a work piece without over-blow

More information

Large Size Vacuum Module:

Large Size Vacuum Module: arge Size acuum Module: Ejector System/acuum ump System arge suction flow rate, suitable when used with large size pads or multiple pads. Nozzle dia. ø., ø., ø.5, ø.8, ø2. acuum module suitable for handling

More information

Vacuum System Peripherals

Vacuum System Peripherals Vacuum System Peripherals Vacuum Regulator/Electronic Vacuum Regulator Vacuum regulator: IRV0/0 Electronic vacuum regulator: ITV009/ITV09 Directional Control Valve Selection guide of directional control

More information

Series ZM Applications

Series ZM Applications Ejector [Option] ll in One! Built-in suction filter and silencer ir supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)

More information

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Vacuum / Release Unit Series VQD1000-V Rubber Seal Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area [Option] Smooth detachment of a work piece without

More information

Vacuum Release Valve with Restrictor

Vacuum Release Valve with Restrictor INFORMATION Series SY3/5 Plug-in Only for External Pilot Vacuum Release Valve with Vacuum suction and release can be controlled with a single valve! PE Pilot EH port Flow rate adjustment of release air

More information

Vacuum Module. Series ZX. Ejector System/Vacuum Pump System

Vacuum Module. Series ZX. Ejector System/Vacuum Pump System Vacuum Module Series ZX Ejector System/Vacuum Pump System For electronic components and precision components up to 0 g Modular design Customized application function through selection of module components.

More information

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is. Port Solenoid Valve Series VQ 00 Unprecedented high speed, stable response, and extra-long service life. ON:.ms, OFF: ms, Dispension accuracy ±ms (With indicator light and surge voltage suppressor; supply

More information

Large Size Vacuum Module:

Large Size Vacuum Module: Large Size acuum Module: System/acuum Pump System Large suction flow rate, suitable when used with large size pads or multiple pads. Nozzle dia. ø1.0, ø1.3, ø1.5, ø1.8, ø2.0 acuum module suitable for handling

More information

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to

More information

Vacuum Ejector. Series ZM

Vacuum Ejector. Series ZM Ejector Series All in One! Built-in suction filter and silencer Air supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)

More information

Large Size Vacuum Module:

Large Size Vacuum Module: Large Size acuum Module: System/acuum Pump System Z Large suction flow rate, suitable when used with large size pads or multiple pads. Nozzle dia. ø1.0, ø1.3, ø1.5, ø1.8, ø2.0 acuum module suitable for

More information

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications Series -SQ00 Port Solenoid Valve Plug-in Unit [Option] How to Order Manifold Electrical entry F kit D-sub connector kit P kit SSQ 08 FD Kit type Flat ribbon cable connector kit J kit Flat ribbon cable

More information

VQ1000. How to Order Manifold. Kit type

VQ1000. How to Order Manifold. Kit type - - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold

More information

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer Base Mounted Metal Seal/Rubber Seal VQ Built-in silencer, direct exhaust Space-saving profile All pilot valves are compactly mounted on one side. The space-saving design of mounting all fittings on one

More information

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Soft Start-up Valve. AV2000/3000/4000/5000 Series Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

Series ZQ. Compact Vacuum Ejector. One-touch fitting. Digital vacuum pressure switch With LED display. ZX ZR ZM ZH ZU ZL ZY ZQ ZF ZP ZCU AMJ Misc.

Series ZQ. Compact Vacuum Ejector. One-touch fitting. Digital vacuum pressure switch With LED display. ZX ZR ZM ZH ZU ZL ZY ZQ ZF ZP ZCU AMJ Misc. Compact acuum Ejector Series Body width mm, Weight9 g (Single unit with vacuum pressure switch and suction filter) Conventional 21.mm mm One-touch fitting ZR ZM ZH ZU ZL ZY ZF Z ZCU AMJ Misc. Digital vacuum

More information

Series ZM Applications

Series ZM Applications Ejector Series ZM All in One! Built-in suction filter and silencer Air supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)

More information

2.26 S OLENOID VALVES S ERIES VQ1000

2.26 S OLENOID VALVES S ERIES VQ1000 2.26 S OLENOID VALVES 5 PORT M ETAL S EAL/RUBBER S EAL U LTRA H IGH S PEED S OLENOID VALVE High Speed Response from new Solenoid Design. Long Life: Over 200 Million Cycles can be with Patent Pilot Valve

More information

Vacuum Ejector. Series ZM Applications

Vacuum Ejector. Series ZM Applications Ejector Series ZM All in One! Built-in suction filter and silencer Air supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) switch (solid state, diaphragm)

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics The ZSE3/E3 series is to be discontinued. We recommend you consider using the Z/E10 series or the

More information

Vacuum Unit Vacuum Ejector Vacuum Pump System RoHS Energy saving ejector Air consumption % reduction More efficient eject

Vacuum Unit Vacuum Ejector Vacuum Pump System RoHS Energy saving ejector Air consumption % reduction More efficient eject acuum Unit acuum Ejector acuum ump System New RoHS Energy saving ejector Digital pressure switch for vacuum with energy saving function cuts supply air when the pressure reached the desired vacuum. Air

More information

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2 Series -PSE3 RoHS Remote Type 2-Color Display Digital Pressure Sensor Controller How to Order 2 3 4 5 Nil Options/Part No. L Input/Output specifications NPN2 output to 5 V output NPN2 output 4 to 2 m output

More information

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000

More information

Large Size Vacuum Module: Ejector System/Vacuum Pump System. Nozzle size (mm): ø1.0, ø1.3, ø1.5, ø1.8, ø2.0

Large Size Vacuum Module: Ejector System/Vacuum Pump System. Nozzle size (mm): ø1.0, ø1.3, ø1.5, ø1.8, ø2.0 Large Size acuum Module: Ejector System/acuum Pump System Nozzle size (mm): ø1.0, ø1.3, ø1.5, ø1.8, ø2.0 acuum module suitable for handling workpieces of 0.5 to 5 kg. Z MJ 13-3-1 Large Size acuum Module:

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

Series AV2000/3000/4000/5000

Series AV2000/3000/4000/5000 Soft Start-up Valve Series AV/3/4/5 Series introduced! A start-up valve that gradually increases supply pressure during start up and rapidly exhausts system air when the supply air is shut off AC AV AU

More information

Fieldbus System (Output device for driving 5 port solenoid valves)

Fieldbus System (Output device for driving 5 port solenoid valves) Fieldbus System (Output device for driving port solenoid valves) New Compact 8mm (ctual size) Space-saving Installation IP67 RoHS EtherNet/IP added! For units with D-sub connector, and when connected to

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

0.35 W (Without light)

0.35 W (Without light) Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:

More information

3 Port 3 Position Valve

3 Port 3 Position Valve Port Position Valve Pilot Solenoid ir Operated ohs Intermediate stopping of cylinders * up to ø15 is possible. Pilot solenoid Manifold ir operated * For VEX 4, 00 mm/s, horizontal movement Power consumption:

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 044 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000 racket

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry TEX Compliant Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 44 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000

More information

Single Valve/Sub-plate Type IP67 Compliant 90-SV Series

Single Valve/Sub-plate Type IP67 Compliant 90-SV Series Single Valve/Sub-plate Type IP7 Compliant -SV Series SV 00 W U aterial restriction Series -SV000 -SV000 Thread type c F G N NPT T NPTF A B SOL.a SOL.a Type of actuation position single (EA) (P)(EB) position

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Series VQ Rubber Seal Space-saving profile Clean space saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type20P 5 Port Solenoid Valve ody Ported Manifold ar Stock Type/Flat Ribbon Cable Series SY3000/5000/7000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 5 20P 05 Manifold series 3 SY3000

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

Vacuum Equipment. Application. Series

Vacuum Equipment. Application. Series Equipment Series Application Page ejector In-line vacuum ejector Multistage ejector ejector with check valve Pad with check valve ejector for water soluble coolant removal ZH ZU ZL1/2 (Special order product)

More information

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position

More information

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch -Color Display Digital Pressure Switch (F)/(H) Series Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor unit: Stainless steel 630 Fitting parts: Stainless steel 304 The sensor unit

More information

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa oolant Valve Series S External pilot solenoid S ir operated S How to Order 0 0 Y 0 0 T Z q w e r t y u i o!0!!!!! q Series S00 S00 S00 w Valve type ormally closed ormally open e Seal material R FKM r Pressure

More information

Manifold Specifications

Manifold Specifications Series 00 Manifold Specifications Manifold Specifications Model Manifold type P(SUP)/R(EXH) Valve stations A port porting specifications Port size For internal pilot For external pilot Location Direction

More information

Fieldbus System (Gateway Decentralized Type)

Fieldbus System (Gateway Decentralized Type) Fieldbus System (Gateway Decentralized Type) * * Except the SY, VQC and S0700 valves GW Unit which supports PROFINET added. New M connector type Input Unit added. Decentralized valve installation Valves

More information

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000 D-sub Connector J Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000//000 Number of connectors: pins MIL-C-08 Conforming to JIS-X-0 --6 For details

More information

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection Rubber Seal Port Solenoid Valve Series SJ000/000 Cassette Type Manifold 0 mm 7. mm (SJ000) 0 mm (SJ000) Non plug-in type Individual wiring manifold SJ000 SJ000 Can be mounted together. Connecter connection

More information

Ejector Valve Unit Series ZYY/ZYX

Ejector Valve Unit Series ZYY/ZYX Ejector Valve Unit Series ZYY/ZYX Series ZYY3 (Solenoid valve: SY3) Nozzle diameter: ø.7, ø1. Type S: Standard type L: Large flow type Ejectors and solenoid valves can be mounted on the same manifold.

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type1P Type2P 5 Port Solenoid Valve ase Mounted Manifold ar Stock Type/Flat Ribbon Cable Series /5000/000 How to Order Manifold Type 1P/Compact style SS5Y 5 1P 05 C8 Manifold series 3 5, port size Thread

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes

More information

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308 Cable ppendix Cable ppendix Multi-way cables The multi-pole connector cables used on SMC valves are common across several ranges. Cables are available in accordance with the MIL standard C-08 and also

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Port Solenoid Valve Metal Seal Rubber Seal Series Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

High Pressure Coolant Valve

High Pressure Coolant Valve High Pressure Coolant Valve Series.5 MPa, 7.0 MPa Corresponding to high speed grinding and long drilling processes Coolant valve for high pressure coolant liquid (up to.5 MPa or 7.0 MPa) that is ideal

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series

More information

Vacuum Pad with Ejector

Vacuum Pad with Ejector IFORMTIO Vacuum ad with Ejector ad Diameter: ø63, ø8 RoHS Ejector and pad are integrated. Space saving and reduced piping labor! Bellows type with groove Two-stage ejector More efficient ejector Suction

More information

3 Port Air Operated Valve

3 Port Air Operated Valve Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

Series VQZ1000/2000/3000 Single Unit

Series VQZ1000/2000/3000 Single Unit +- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Rubber Seal Series VQ Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

VXP21/22/23 Series. Pilot Operated 2 Port Solenoid Valve. For Air, Gas, Steam, Water and Oil VX2 VXK VXD VXZ VXS VXB VXE VXP VXR VXH VXF VX3 VXA

VXP21/22/23 Series. Pilot Operated 2 Port Solenoid Valve. For Air, Gas, Steam, Water and Oil VX2 VXK VXD VXZ VXS VXB VXE VXP VXR VXH VXF VX3 VXA Pilot Operated Port Solenoid Valve VXP//3 Series For ir, as,, Water and Oil Variations.O..C. Wide variations of combination. ble to control a wide variety of fluids. Valve can be matched to particular

More information

Example. U side. Stations SY5000

Example. U side. Stations SY5000 45 Type 5 ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN ail Mounted/Individual Wiring Series SY3000/5000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 3 45 05 U C6 Example

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve CT.E- ase Mounted Type Series VQ Port Metal Seal/Rubber Seal Solenoid Valve dvanced manifold va the new age of factory au ase Mounted Type Space saving profile Clean space saving design with all pilot

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

5 Port Solenoid Valve Plug Lead Type

5 Port Solenoid Valve Plug Lead Type 5 Port Solenoid alve Plug Lead Type Series Body Ported Flow rate characteristics For single/double solenoid C [dm 3 /(s bar)]: 0.6 Single Unit alve width: 7.4 mm Possible to drive cylinders: Up to ø32

More information

Vacuum Ejector with Solid State Timer

Vacuum Ejector with Solid State Timer Vacuum Ejector with Solid State Timer Incorporates solid state timer function for release valve control (Timer setting with PLC is unnecessary) Timing Chart OFF Suction command ON Suction output OFF ON

More information

3 -color/2-screen display

3 -color/2-screen display -color display -color/-screen display Main screen Sub screen Note ) Main screen Sub screen Note ) ccumulated value New Digital Flow Switch for Water Instantaneous flow rate Set value Note ) Peak/ottom

More information

MULTISTAGE MICRO EJECTORS

MULTISTAGE MICRO EJECTORS MULTISTAGE MICRO EJECTORS MED07-E, MED10-E Specifications Basic model Item Media Operating pressure range MPa [psi.] Proof pressure MPa [psi.] Operating temperature range (atmosphere and media) C [ F]

More information

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS MULTISTAGE MICRO EJECTORS CONTENTS MED07-E, MED10-E Series Specifications 715 Order Codes 716 Operation Principle

More information

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot 3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in

More information

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S. High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure of 0.5MPa, subject to clean, dry air) 4 Port Direct

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

Vacuum pump system type

Vacuum pump system type type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated

More information

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Vacuum Release Valve with Restrictor Series SJ3A6 SJ Plug-in Type Connector Connection P.86 D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Non Plug-in Type Individual

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Settings can be copied to up to 1 slave sensors at once. The settings of the master sensor can be copied to the slave sensors. Reduced setting efforts

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Air Suction Filter. Series ZF. Prevent from occurring vacuum equipment trouble due to dust from vacuum pad ZFA ZFB ZFC

Air Suction Filter. Series ZF. Prevent from occurring vacuum equipment trouble due to dust from vacuum pad ZFA ZFB ZFC Air Suction Filter Series ZF Prevent from occurring vacuum equipment trouble due to dust from vacuum pad Series ZFA ZF Universal joint type Features Long maintenance cycle type (Large filter surface) Adaptable

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

Coolant Valve. Air Operated/External Pilot Solenoid

Coolant Valve. Air Operated/External Pilot Solenoid Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) lange type (3 to ) Low water hammer or details, refer to page

More information