Series ZQ. Compact Vacuum Ejector. One-touch fitting. Digital vacuum pressure switch With LED display. ZX ZR ZM ZH ZU ZL ZY ZQ ZF ZP ZCU AMJ Misc.
|
|
- Jerome Edwards
- 5 years ago
- Views:
Transcription
1 Compact acuum Ejector Series Body width mm, Weight9 g (Single unit with vacuum pressure switch and suction filter) Conventional 21.mm mm One-touch fitting ZR ZM ZH ZU ZL ZY ZF Z ZCU AMJ Misc. Digital vacuum pressure switch With LED display Series ariations Series Nozzle diameter mm Release valve acuum pressure switch Suction filter 7 1 ø0. ø0.7 ø1.0 N.C. N.O. Latching N.C. 1 NN output and analog output 1 N output and analog output 2 NN outputs 2 N outputs Filtration 30 µm
2 Compact acuum Ejector Series Ejector unit How to Order U K1 L D31 C Nozzle nominal size U 3M Ejector exhaust Solenoid valve combination (Refer to Table (1).) Symbol K1 K2 J1 J2 Q1 Q2 ø0. ø0.7 ø1.0 Silencer for single unit Silencer for manifold N.C. N.O. N.C. N.O. Latching positive common Latching positive common ilot valve (Refer to Table (1).) Standard type (1 W for DC) Note) Y DC low wattage type (0. W) L LO G Release valve N.C. N.C. None None N.C. None Note) In the case of the manifold type or when single unit valves are aligned closely with each other, avoid energization lasting more than 3 days. oltage (Refer to Table (1).) AC 200 AC 1 AC 220 AC 24 DC 12 DC Electrical entry L plug connector, With 0.3 m lead wire With light/surge voltage suppressor L plug connector, Without connector With light/surge voltage suppressor Grommet, With 0.3 m lead wire (Not available for latching and AC types.) acuum switch electrical entry Manual override Non-locking push type Latching: ush-lock type B Locking slotted type C CL CN Check valve None K With check valve Note) The check valve has a function to prevent the exhaust air from the silencer overflowing to the vacuum port side when a manifold is used. Warning q Cannot be used for vacuum retention. w Use a release valve. (Without a release valve, the work piece may not be released.) Connector type Lead wire length: 0. m Connector type Lead wire length: 3 m Connector type Without connector acuum pressure switch suction filter F only 1 NN output and analog output, D31 suction filter 2 NN outputs, D32 suction filter 1 N output and analog output, D1 suction filter 2 N outputs, D2 suction filter Only the type manual override is available with a latching type supply valve. In such cases, the supply valve and release valve come with a lock. Table (1) Combination of solenoid valve, pilot valve and power supply voltage q w e r t y u i Solenoid valve combination symbol K1 K1 K2 J1 J1 J2 Q1 Q2 ilot valve symbol Y Y AC 0 Combinations (1) to (8) in the above table are the only possible options Applicable power supply voltage AC 200 AC 1 AC 220 DC 24 DC 12
3 How to Order Compact acuum Ejector Series Manifold Z1 08 B S B Nozzle nominal size ø0. ø0.7 ø1.0 Manifold Ordering Example Number of stations Note) 01 1 station 02 2 station station Note) Number of stations varies according to nozzle nominal size during simultaneous operation. Maximum number of stations in simultaneous operation Maximum number of stations in simultaneous operation 8 Stations Stations 4 Stations Z8-BSB 1 pc. 3M-K1YL-D31C 4 pcs. (Stations 1 to 4) 13M-K1YL-D31C 4 pcs. (Stations to 8) The stations are sequentially numbered. When viewed from the side of the vacuum ports, the far left station is designated as station 1. Left acuum port ka MODE SET1 SET2 ka MODE SET1 SET2 ka MODE SET1 SET2 ka MODE SET1 SET2 3M-K1YL-D31C ka MODE SET1 SET2 ka MODE SET1 SET2 ka MODE SET1 SET ka MODE SET1 SET2 13M-K1YL-D31C Right ilot exhaust port location B Both sides Exhaust S Silencer (Both sides) Supply port location B Both sides Flow Characteristics/Exhaust Characteristics Exhaust Characteristics Maximum vacuum pressure (ka) Maximum vacuum pressure (ka) -0 Maximum vacuum pressure 20 1 Air consumption Maximum suction flow Maximum suction flow (l/min(anr)) Air consumption (l/min(anr)) Supply pressure (Ma) Suction flow (l/min(anr)) 7 Exhaust Characteristics -0 Maximum vacuum pressure Air consumption Maximum suction flow Supply pressure (Ma) Maximum suction flow (l/min(anr)) Air consumption (l/min(anr)) 1 Exhaust Characteristics Flow Characteristics Maximum vacuum pressure (ka) Maximum vacuum pressure (ka) -0 7 Flow Characteristics Suction flow (l/min(anr)) 1 Flow Characteristics ZR ZM ZH ZU ZL ZY ZF Z ZCU AMJ Misc. Maximum vacuum pressure (ka) -0 Maximum vacuum pressure Air consumption Maximum suction flow Maximum suction flow (l/min(anr)) Air consumption (l/min(anr)) Maximum vacuum pressure (ka) Supply pressure (Ma) Suction flow (l/min(anr))
4 Series Specifications Ejector Model Nozzle nominal diameter mm ø Maximum suction flow l/min(anr) Air consumption l/min(anr) Maximum vacuum pressure ka Supply pressure range 0.3 Ma to 0. Ma Supply pressure Operating temperature range 0.3 Ma 0.43 Ma to 0 C Weight Single unit Note 1) 9 Switch and suction filter End plate assembly for manifold g 9 g 122 g Note 1) Including a 0.3 m connector for the supply and release valves. Including a 0.3 m connector for the supply and release valves and a 0. m connector for the switch. Calculation of weight for the manifold type (Single unit weight) x (Number of stations) + (Weight of end plate assembly for manifold) Example) Switch + 8 stations with suction filter 9 g x g = 994 g Supply alve and Release alve Type (Refer to How to Order for solenoid Model valves on page ) Fluid Maximum operating pressure Minimum operating pressure Ambient and fluid temperature Lubrication Manual override Rated coil voltage ower consumption (current value) Electrical entry DC 0 AC 1 AC 200 AC 220 AC Standard type Q1- Normally closed type Low wattage type (0. W) Q1Y- Air, Inert gas 0. Ma 0.3 Ma to 0 C Not required Latching type Q1L- Normally open type 1-Q120- Non-locking push type / Lock type (tool type) ush-lock type Non-locking push type / Lock type (tool type) 12, 24 DC, 0, 1, 200, 220 AC 12, 24 DC 1 W 0. W 1 W 0. A ( ma) 0. A ( ma) 1.0 A ( ma) 1.1 A ( ma) 0. A ( ma) 0. A (.9 ma) 1.2 A ( ma) 1.3 A (.9 ma) Grommet L plug connector Grommet L plug connector With light/surge L plug connector With light/surge (With light/surge voltage suppressor) voltage suppressor ( voltage suppressor) acuum ressure Switch Model Refer to How to Order for vacuum pressure switches on page ( ) Rated pressure range Set pressure range Withstand pressure Fluid ower supply voltage Current consumption Ambient temperature range Ambient humidity range Withstand voltage Insulation resistance Switch output Maximum load current Maximum applied voltage Residual voltage Response time Hysteresis Display Display accuracy Output indicator light Analog output Note) Output voltage Linearity 1S-D31--AS 1S-D1--AS 1S-D32--AS 1S-D2--AS 0 to 0 ka 0 to 99 ka 0.2 Ma Air/Non-corrosive metal/non-combustible gas 12 to 24 DC ±% 3 ma or less [with power supply voltage of 24 DC and switch output ON (with no load)] to 0 C (with no freezing or condensation) 3 to 8 %RH in operation and saving (with no condensation) 00 AC for 1 min 0 MΩ or more (between live parts and pressure port at 00 DC) 1 NN output and analog output 1 N output and analog output 2 NN outputs 2 N outputs 80 ma (per output) 30 (for NN output) NN output: or less (at 80 ma inrush), N output: 1.2 or less (at 80 ma discharge) 2 ms or less 0 to 1% F.S. or less (adjustable) 2% F.S. or less (fixed) 0 to 1% F.S. or less (adjustable) 2% F.S. or less (fixed) 2-digit red LED ±3 %F.S. ±2 digits Lights up when output is ON (red LED). Lights up when output is ON (red for OUT1 and green for OUT2) (Only applicable to D31 and D.1) 1 to ±2.% F.S. or less ±0. F.S. or less
5 Compact acuum Ejector Series Construction Single unit Manifold t e r y o w q Component arts No. Description Material No. q w e r oppet valve assembly Nozzle Diffuser Release flow adjustment needle Aluminum Aluminum Aluminum t y u i o Solenoid valve Y L ilot valve Standard type (1W) DC low wattage type (0. W) Not available for AC type Latching positive common Actuation 1 Normally closed 1 Q1 2 0 u i Rated coil voltage Q1 1 0 L How to Order L 0 AC 200 AC 1 AC 220 AC 24 DC 12 DC Replacement arts Description Material art no. Solenoid valve Filter element Sound absorbing material 1 (single unit) acuum pressure switch Sound absorbing material 2 (manifold) F F F Refer to How to Order below XT AS XT Refer to How to Order below XT Check valve K None With check valve Note) The check valve has a function to prevent the exhaust air from the silencer overflowing to the vacuum port side when a manifold is used. Warning q Cannot be used for vacuum retention. w Use a release valve. (Without a release valve, the workpiece may not be released.) acuum pressure switch 1S D 31 C AS ZR ZM ZH ZU ZL ZY ZF Z ZCU AMJ Misc. Actuation 2 Normally open Rated coil voltage 24 DC 12 DC ilot valve Standard type (1W) Electrical entry L plug connector L With 0.3 m lead wire L plug connector LO Without connector Grommet G With 0.3 m lead wire (Not available for latching and AC types.) Note) Mounting screws are attached Manual override Non-locking push type Latching: ush-lock type B Locking: Slotted type Note) Only the "" type is available with a latching type. Switch specifications 1 NN output and analog output 2 NN outputs 1 N output and analog output 2 N outputs Electrical entry Connector type C Lead wire length: 0. m Connector type CL Lead wire length: 3 m CN Without connector Note) Mounting screws are attached
6 Series Dimensions Type K1 11U-K1- ilot exhaust port ( port) (M3 x 0., piping not required) Air supply port ( port) (M x ) (74.9) Lead wire length (approx. 0.3 m) (49.) (Grommet type) (3.1) ø3. Mounting Bracket A (standard) Release valve 7 Release flow adjusting screw acuum pressure switch ka MODE SET HYS acuum port ( port) (M x ) Circuit 11U-K1- D F DK Note 1) The above dimensions are for 11U-K1 -DC. In the case of 11U-K1-F, the overall length is Dimensions marked with are those after bracket A is mounted. Note 3) When the body is mounted, tighten with a torque of 0.±0.0 Nm. The pitches of, and ports are determined assuming the use of the Series dependant on their type and size. lease refer to the catalogue to confirm the Type J1 11U-J1- ilot exhaust port ( port) (M3 x 0., piping not required) Air supply port ( port) (M x ) Circuit (3.1) (AC type) 3. (3.1) 11U-J1- D F Bracket A (standard) 7 acuum pressure switch Note 1) The above dimensions are for 11U-J1 L-DC. In the case of 11U-J1-F, the overall length is The dimensions after bracket A is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0.±0.0 Nm. The pitches of, and ports are determined assuming the use of the Series dependant on their type and size. lease refer to the catalogue to confirm the ka MODE SET HYS acuum port ( port) (M x ) 13-9-
7 Compact acuum Ejector Series Dimensions Type K2 11U-K2- Release flow adjusting screw ilot exhaust port ( port) (M3 x 0., piping not required) Air supply port ( port) (M x ) Circuit 11U-K2- (8.4) F D DK 2.8 Bracket A (standard) 87.2 Release valve 7.3 acuum port ( port) (M x ) Note 1) The above dimensions are for 11U-K2 L-F. In the case of 11U-K2-D, the overall length is 7. The dimensions after bracket A is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0.±0.0 Nm. The pitches of, and ports are determined assuming the use of the Series dependant on their type and size. lease refer to the catalogue to confirm the ZR ZM ZH ZU ZL ZY ZF Z ZCU AMJ Misc. Type J2 11U-J2- ilot exhaust port ( port) (M3 x 0., piping not required) Air supply port ( port) (M x ) (8.4) Bracket A (standard) 87.2 acuum port ( port) (M x ) Note 1) The above dimensions are for 11U-J2 L-F. In the case of 11U-J2-D, the overall length is 7. The dimensions after bracket A is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0.±0.0 Nm. The pitches of, and ports are determined assuming the use of the Series dependant on their type and size. lease refer to the catalogue to confirm the Circuit 11U-J2- F D
8 A A Series Dimensions Type Q1 11U-Q1- Release flow adjusting screw ilot exhaust port ( port) (M3 x 0., piping not required) Air supply port ( port) (M x ) (3.1) 3. B 0 Bracket A (standard) Release acuum pressure switch valve ka MODE SET HYS acuum port ( port) (M x ) Circuit 11U-Q1- D F DK Note 1) The above dimensions are for 11U-G1 L-DC. In the case of 11U-Q1-F, the overall length is The dimensions after bracket A is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0.±0.0 Nm. The pitches of, and ports are determined assuming the use of the Series dependant on their type and size. lease refer to the catalogue to confirm the Type Q2 11U-Q2- ilot exhaust port ( port) (M3 x 0., piping not required) Air supply port ( port) (M x ) (3.1) 3. 0 B Bracket A (standard) 7 acuum pressure switch ka MOD E S E T HYS acuum port ( port) (M x ) Circuit 11U-Q2- D F Note 1) The above dimensions are for 11U-G2 L-DC. In the case of 11U-G2-F, the overall length is The dimensions after bracket A is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0.±0.0 Nm. The pitches of, and ports are determined assuming the use of the Series dependant on their type and size. lease refer to the catalogue to confirm the
9 Compact acuum Ejector Series Dimensions Manifold type Z1-BSB 13M-- Supply port 2-ø3. ( Note 1) ) L2 (3.) (0.1) L1. 13 (itch) = 8 ( Note 1) ) 3 Attached washer 3. 2-R1.7 ilot exhaust port ( port) (One-touch fitting for applicable tubing diameter of ø4, piping not required) Common air supply port ( port) (One-touch fitting for applicable tubing diameter of ø8) Release valve Release flow adjusting screw acuum pressure switch Attached washer (72.4).2 ka MO DE SET HYS ka MO DE SET HYS ka MO DE SET HYS ka MO DE SET HYS ZR ZM ZH ZU ZL ZY ZF Z ZCU AMJ Misc. Dimensions n L1 L n: Number of stations (mm) acuum port ( port) (M x ) Note 1) The above dimensions are for Z1-BSB. 13M-K L-DC. In the case of 13M--F, the overall length is Dimensions marked with " " are those after the attached square bracket is mounted. Note 3) When the body is mounted, tighten with a torque of 0.±0.0 Nm. The pitches of ports are determined assuming the use of the Series KJ onetouch fittings. If used with other fittings, these may cause interference, dependant on their type and size. lease refer to the catalogue to confirm the sizes of the fittings to be used. Circuit 13M-K1-D 13M-K2-DK 13M-J1-F 13M-Q1-FK
10 Series Manifold Exploded iew 3 4 b 4 b view 2 a a Component arts No. q w e r t y Description Hexagon socket head cap screw End block R End block L Ejector assembly Ejector body gasket for manifold Exhaust block gasket art no. Refer to How to Order. 1R-1-BSB-AS 1L-1-BSB-AS 13M-- Note) Note) Refer to page for detailed description of How to Order. 1 How to Order Hexagon Socket Head Cap Screw XT Number of stations 0 1 station 0 2 station 12 8 station Working rocedure Disassembly Loosen and remove the hexagon socket head cap bolts q. Assembly 1. Install the ejector body gasket for manifold t into the gasket groove of each ejector assembly r. Install the exhaust block gasket y around the projected part. 2. Install the exhaust block gasket y around the projected part of the end block R w. 3. Install the ejector body gasket for manifold t into the gasket groove of the end block L e. 4. Align the ejector assemblies r, end block (R) w, and end block (L) e using positioning pins (at the two a positions) and fasten with a hexagon socket head cap bolts q (2 pcs.) (with a tightening torque of 0. Nm±0.0 Nm)
Space Saving Vacuum Ejector/Vacuum Pump System
Space Saving acuum Ejector/acuum ump System Series Current 21.6 mm mm Width mm [Option] Weight 9 g Single unit with vacuum pressure switch and suction filter ZK2 ZR Z Z ZM ZL -X267 ZU Ejector.2 ump System.118
More informationCompact Vacuum Ejector
Compact acuum Ejector Series ZA Total length Total width 7.9 mm 9.9 mm Total height. mm Response time 0 ms Response time for up to 0 ka Nozzle diameter: ø0.7 iping: ø/ø. x 0 mm Able to install on the moving
More informationSpace Saving Vacuum Ejector / Vacuum Pump System
CT.US0-1'-UK Space Saving acuum jector / acuum ump System Conventional ZX 21. mm mm ZQ Series ZQ Width mm Weight 9 g Single unit with vacuum pressure switch and suction filter jector ump System NW asy-to-use
More informationQ1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.
Multistage Ejector 112/212 Series Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus
More informationVSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter
Basic performance oriented general vacuum ejector unit Series Nozzle diameter: ø.5, ø, ø1. acuum switch and vacuum break valve, etc. are unitized, so types matching the work purpose is selectable. Features
More informationVacuum Equipment. Application. Series
Equipment Series Application Page ejector In-line vacuum ejector Multistage ejector ejector with check valve Pad with check valve ejector for water soluble coolant removal ZH ZU ZL1/2 (Special order product)
More informationEjector Valve Unit Series ZYY/ZYX
Ejector Valve Unit Series ZYY/ZYX Series ZYY3 (Solenoid valve: SY3) Nozzle diameter: ø.7, ø1. Type S: Standard type L: Large flow type Ejectors and solenoid valves can be mounted on the same manifold.
More informationVacuum Unit Vacuum Ejector Vacuum Pump System RoHS Energy saving ejector Air consumption % reduction More efficient eject
acuum Unit acuum Ejector acuum ump System New RoHS Energy saving ejector Digital pressure switch for vacuum with energy saving function cuts supply air when the pressure reached the desired vacuum. Air
More informationEnergy saving ejector
acuum Unit ZK2 Series acuum acuum ump RoHS Energy saving ejector Digital pressure switch for vacuum with energy saving function cuts supply air when the pressure reached the desired vacuum. ir consumption
More informationVacuum Ejector with Solid State Timer
Vacuum Ejector with Solid State Timer Incorporates solid state timer function for release valve control (Timer setting with PLC is unnecessary) Timing Chart OFF Suction command ON Suction output OFF ON
More informationVacuum Ejector. Series ZM
Ejector Series All in One! Built-in suction filter and silencer Air supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)
More informationLarge Size Vacuum Module:
arge Size acuum Module: Ejector System/acuum ump System arge suction flow rate, suitable when used with large size pads or multiple pads. Nozzle dia. ø., ø., ø.5, ø.8, ø2. acuum module suitable for handling
More informationNozzle diameter: ø0.5, ø0.7, ø1.0, ø1.2. Features
ariety of modularized units enable selections of integrated type ejector units suitable for the application. K eries Nozzle diameter: ø0.5, ø0.7, ø1.0, ø1.2 ZM Q G Y H U B C K KM J JM X XM Features acuum
More informationTerminal Block Box (Spring Type) SY3000/5000/7000 Series
INFORMATION 5 ort olenoid alve Terminal lock ox (pring Type) Y3000/5000/7000 eries Compact RoH Height 6.7 mm shorter (Approx. 9% reduction) Installation area of the terminal block box Reduced by approx.
More informationEnergysaving. (10 mm) 3.09 inch (78.5 mm) Silencer (Built-in)
Compact acuum Unit Ejector/acuum Pump System Quick response Compact/ Lightweight Response time of the : 5 ms acuum response time: 28 ms (Shortened by 25%; Comparison with other SMC products) Conditions:
More informationCompact Vacuum Unit Ejector/Vacuum Pump System. 46 g. New. 17% reduced 21% 10 mm mm mm. Series ZB. Response time of the valve: 5 ms
Compact acuum Unit Ejector/acuum Pump System New RoHS Quick response Compact/ Lightweight Response time of the : ms acuum response time: 8 ms (Shortened by %; Comparison with other SMC products) Conditions:
More informationVacuum Ejector. Series ZM Applications
Ejector Series ZM All in One! Built-in suction filter and silencer Air supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) switch (solid state, diaphragm)
More informationLarge Size Vacuum Module: Ejector System/Vacuum Pump System. Nozzle size (mm): ø1.0, ø1.3, ø1.5, ø1.8, ø2.0
Large Size acuum Module: Ejector System/acuum Pump System Nozzle size (mm): ø1.0, ø1.3, ø1.5, ø1.8, ø2.0 acuum module suitable for handling workpieces of 0.5 to 5 kg. Z MJ 13-3-1 Large Size acuum Module:
More information3 Port Solenoid Valve
ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M. V3 Cover
More informationCompact Vacuum Unit. 46 g Single unit weight. New RoHS. 17% reduced 21% Ejector/Vacuum Pump System. 10 mm mm mm.
Compact acuum Unit Ejector/acuum Pump System New RoHS Quick response Compact/ Lightweight Response time of the : ms acuum response time: 8 ms (Shortened by %; Comparison with other SMC products) Conditions:
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body
More informationVacuum Ejector. Adaptable for manifold application
Vacuum Ejector Series ZM ZX All in One! Built-in suction filter and silencer Air supply valve for generating a vacuum Vacuum release valve (equipped with a flow volume adjustment valve) Vacuum pressure
More informationHow to Order. 0.5 mmø 0.7 mmø mmø mmø mmø mmø mmø. Maximum vacuum pressure S L. 88 kpa 48 kpa. SUP.
Vacuum Ejector How to Order Note Refer to Table (1) and (2) for the combination available for SUP, VAC and EXH port connection. ZH 07 B S 06 06 ZH 07 D S 01 01 01 Nozzle diameter 05 07 0.5 mmø 0.7 mmø
More informationVacuum / Release Unit
Rubber Seal Vacuum / Release Unit Series VQD1000-V Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area Smooth detachment of a work piece without over-blow
More informationHow to Order Single Unit 25A-ZK2 A 12 N 0 N N 08. e Combination of supply valve Note 3) and release valve. Note 5) K. Note 6)
Vacuum Unit RoHS Series 25A-ZK2 How to Order Single Unit Ejector System (with Valve) Ejector System (without Valve) 25A-ZK2 A 12 K 5 A 08 25A-ZK2 A 12 0 08 q w e r t y u i Remains blank when option is
More information5 Port Solenoid Valve
ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high
More information5 Port Solenoid Valve
Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size
More informationSeries SYJ300/500/700
ort Solenoid Valve ubber Seal Series SYJ00/00/00 Low power consumption: 0.W (Without light) (Current draw: 1m at 4V DC) Completely interchangeable ilot exhaust with the previous series VJ00/00/00 and VZ00/00.
More information13 msec (at 500 mm )/18.5 msec (at 1000 mm )
Vacuum / Release Unit Series VQD1000-V Rubber Seal Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area [Option] Smooth detachment of a work piece without
More informationMULTISTAGE MICRO EJECTORS
MULTISTAGE MICRO EJECTORS MED07-E, MED10-E Specifications Basic model Item Media Operating pressure range MPa [psi.] Proof pressure MPa [psi.] Operating temperature range (atmosphere and media) C [ F]
More informationLarge Size Vacuum Module:
Large Size acuum Module: System/acuum Pump System Large suction flow rate, suitable when used with large size pads or multiple pads. Nozzle dia. ø1.0, ø1.3, ø1.5, ø1.8, ø2.0 acuum module suitable for handling
More informationSpecifications. Fluid Ambient and fluid temperature ( C)
Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication
More informationVacuum Module. Series ZX. Ejector System/Vacuum Pump System
Vacuum Module Series ZX Ejector System/Vacuum Pump System For electronic components and precision components up to 0 g Modular design Customized application function through selection of module components.
More informationRubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot
ubber seal ort ilot Solenoid Valve Series SYJ00 Specifications efer to www.smcworld.com for details of products compatible with overseas standards. Body ported Base mounted Fluid Operating pressure range
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body
More information10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry
Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available
More information5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted
Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted
More information5 Port Solenoid Valve
ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and
More informationMULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution
ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS MULTISTAGE MICRO EJECTORS CONTENTS MED07-E, MED10-E Series Specifications 715 Order Codes 716 Operation Principle
More informationISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I
ISO Standard Solenoid Valve Series VQ7-6/7-8 (Size ) (Size ) Conforms to ISO Standard /I.0- Ideal for driving cylinders up to Large flow capacity ø00 (VQ7-6, Size ) ø60 (VQ7-8, Size ) Nl/min VQ7-6: 668.
More informationSeries VQ Port Solenoid Valve
Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors
More information3 Port Solenoid Valve
Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series
More informationVacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm
4 Port Direct Operated Poppet Solenoid Valve Series D1000 High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure
More informationLarge Size Vacuum Module:
Large Size acuum Module: System/acuum Pump System Z Large suction flow rate, suitable when used with large size pads or multiple pads. Nozzle dia. ø1.0, ø1.3, ø1.5, ø1.8, ø2.0 acuum module suitable for
More informationSeries ZM Applications
Ejector Series ZM All in One! Built-in suction filter and silencer Air supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)
More informationPilot Operated 2 Port Solenoid Valve for Dry Air
Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0
More informationCable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308
Cable ppendix Cable ppendix Multi-way cables The multi-pole connector cables used on SMC valves are common across several ranges. Cables are available in accordance with the MIL standard C-08 and also
More informationExhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)
5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body
More information2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating
/ ort Solenoid Valve ubber Seal Series SYJ000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Specifications JIS Symbol port port (manifold) position
More informationSeries VQZ1000/2000/3000 Single Unit
+- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body
More informationVacuum pump system type
type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated
More information3 Port Solenoid Valve
Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly
More informationSeries VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4
Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double
More information3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)
ort Solenoid Valve ubber Seal Series SY00 Low power consumption: 0.W (Standard, Without light) (Current draw: m at V DC) Large flow capacity style:0.7w (Current draw: m at V DC) Body width: 0mm 7.8 Nl/min
More informationPower Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.
Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control
More informationBody width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.
High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure of 0.5MPa, subject to clean, dry air) 4 Port Direct
More information5 Port Solenoid Valve
ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series
More information5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles
ort Solenoid Valve: ase Mounted Metal Seal/Rubber Seal Series Space and capacity saving ilot valve is gathered at one side. Space saving design which does not have any protrusions. Space saving Capacity
More informationHow to Order Single Unit 25A-ZK2 A 12 N 0 N N 08. e Combination of supply valve Note 3) and release valve. Note 5) K
Vacuum Unit RoHS Series 25-ZK2 How to Order Single Unit Ejector System (with Valve) Ejector System (without Valve) 25-ZK2 12 K 5 08 25-ZK2 12 0 08 q w e r t y u i Remains blank when option is not selected.
More informationAir Suction Filter. Series ZF. Prevent from occurring vacuum equipment trouble due to dust from vacuum pad ZFA ZFB ZFC
Air Suction Filter Series ZF Prevent from occurring vacuum equipment trouble due to dust from vacuum pad Series ZFA ZF Universal joint type Features Long maintenance cycle type (Large filter surface) Adaptable
More information3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot
3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in
More informationVacuum Release Valve with Restrictor
INFORMATION Series SY3/5 Plug-in Only for External Pilot Vacuum Release Valve with Vacuum suction and release can be controlled with a single valve! PE Pilot EH port Flow rate adjustment of release air
More information3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.
Port Solenoid Valve Series VQ 00 Unprecedented high speed, stable response, and extra-long service life. ON:.ms, OFF: ms, Dispension accuracy ±ms (With indicator light and surge voltage suppressor; supply
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time
More informationBlanking. External Vacuum spec. (V) Standard pilot spec. (R) Vacuum spec. (V) Standard
Solenoid valve Compact 1, SYJ Compact size: 1 mm (1, SYJ) 15 mm (SYJ5) 18 mm (SYJ7) Low power consumption:.1 W QZ 1 mm: QZ1 15 mm: QZ2 18 mm: QZ K KF Compact 2 port valve X2 T T7/17/25 P P/5/7 G42 1 SYJ/5/7
More information2.26 S OLENOID VALVES S ERIES VQ1000
2.26 S OLENOID VALVES 5 PORT M ETAL S EAL/RUBBER S EAL U LTRA H IGH S PEED S OLENOID VALVE High Speed Response from new Solenoid Design. Long Life: Over 200 Million Cycles can be with Patent Pilot Valve
More informationSeries ZM Applications
Ejector [Option] ll in One! Built-in suction filter and silencer ir supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)
More information5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal
Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage
More informationExample. U side. Stations SY5000
45 Type 5 ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN ail Mounted/Individual Wiring Series SY3000/5000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 3 45 05 U C6 Example
More informationPilot Operated 2 Port Solenoid Valve for Dry Air
Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible
More informationHow to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1
Port Solenoid Valve Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Non plug-in manifold 0 0 S 60 Stations stations 0 stations SUP/EXH
More informationPower Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.
Power Valve: Regulator Valve Series 1 Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control
More informationVQ1000. How to Order Manifold. Kit type
- - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold
More information5 Port Solenoid Valve Direct Operated Poppet Type. Specifications
Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W
More informationSeries VP3145/3165/3185
Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to
More informationSeries VP3145/3165/3185
Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes
More information4/5 Port Solenoid Valve
ubber Seal / ort Solenoid Valve Series 000 / 000 / 000 [Option] SJ SY SV SZ V S000 VQ VQ VQ VQC VQZ SQ VFS VF VQ Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread
More information3 Port Air Operated Valve
Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation
More informationExternal vacuum controller
By newly adding pressure adjusting function to blow-off flow adjusting function, it enables to prevent works from being blown away. A relief mechanism built into the blow-off circuit which breaks the vacuum
More informationSeries ZM Applications
Ejector [Option] ll in One! Built-in suction filter and silencer ir supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)
More information4/5 Port Solenoid Valve
CT.ES8 / ort Solenoid Valve Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M.7 to M2. 앬 Flow Characteristics Series Cover (stainless
More information5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range
For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR2 JIS Symbol type
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model 2 position 3 position
More information2-Color Display High-Precision Digital Pressure Switch
2-Color Display High-Precision Digital Pressure Switch Settings can be copied to up to 1 slave sensors at once. The settings of the master sensor can be copied to the slave sensors. Reduced setting efforts
More informationManual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry
Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal
More informationPower Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit
CT.EUS8 UK ower Consumption / ort Solenoid Valve With ower Saving Circuit Series SYJ000/000/7000 Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced
More informationI N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications
I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000
More information3 Port Solenoid Valve
Rubber Seal Port Solenoid Valve Series Manifold Single Unit ase Mounted Manifold VV01 V100 ar base P.18 ody Ported P.10 ase Mounted P.10 VQD VKF VK VT VS Separable base ody Ported Manifold P.1 Stacking
More information3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option
Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable
More information5 Port Solenoid Valve Direct Operated Poppet Type. Specifications
Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W
More informationVacuum ejector and vacuum unit model series variations
acuum ejector and vacuum unit model series variations acuum ejector/vacuum unit Type uitable types for Ejector system uitable types for acuum pump system roduct name acuum ejector stand-alone type acuum
More information3 Port Solenoid Valve
3 ort Solenoid Valve Series VKF300 ubber Seal Direct Operated oppet Type Compact yet provides a large flow capacity Body width 8 mm vailable in vacuum applications ( 0. ka) Can be used in vacuum/release
More informationBase Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer
Base Mounted Metal Seal/Rubber Seal VQ Built-in silencer, direct exhaust Space-saving profile All pilot valves are compactly mounted on one side. The space-saving design of mounting all fittings on one
More information4 Port Solenoid Valve
Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean
More information5 Port Solenoid Valve
5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry
More informationPower Valve: Economy Valve. Standard Specifications. Model VEX55-04
Three functions (pressure regulator, switching valve, and speed controller) are provided by a single valve. The conventional valve combination circuit has been condensed into a single valve. A large capacity
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position
More informationRelated vacuum products
Vacuum component C O N T E N T S variation 420 Position locking valve () 422 Compact vacuum regulator () 426 Vacuum break unit () 436 Vacuum filter large volume union type (VSFB) 440 Compact vacuum filter
More information3 Port Solenoid Valve Direct Operated Poppet Type
3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage
More information