Port size. 4(A), 2(B) port SV /2(P A/B) 4/2 3/5(A/B E) b

Size: px
Start display at page:

Download "Port size. 4(A), 2(B) port SV /2(P A/B) 4/2 3/5(A/B E) b"

Transcription

1 Valve Manifold Common Specifications For details about certified products conforming to international standards, visit us at Cassette base manifold Changing the number of stations can be easily done by lever operation. Flow Characteristics Model SSV-6 SSV-6,, (,, ) C C0 ort size, (, ) C6 C C [dm /(s bar)] 0.9. Manifold Specifications pplicable series Manifold type (: S)/, (: XH) type Valve stations (maximum) Max. number of solenoids (), /() port ort size (), () port Note) The value is for manifold base with stations and individually operated position type. Stacking type cassette base manifold Common S, XH stations 0 stations points 6 points C, N9 C0, N C, C, C6 C, C6, C N, N, N7 N, N7, N9 Flow characteristics / ( /) / / (/ ) b Cv C [dm /(s bar)] b Cv Tie-rod base manifold pins connector allows up to 6 stations with double solenoids. Manifold Specifications pplicable series Manifold type (: S)/, (: XH) type Valve stations (maximum) Max. number of solenoids (), /() port ort size (), () port Flow Characteristics C, N9 C, C, C6 N, N, N7 Tie-rod base manifold Common S, XH 0 stations points C0, N C, C6, C N, N7, N9 C, N C6, C, C0 N7, N9, N ort size Flow characteristics Model,,, /( /) / /(/ ) SSV-0 SSV-0 SSV-0 SSV-0 (,, ) C C0 C C (, ) C6 C C0 C C [dm /(s bar)] b Cv C [dm /(s bar)] b Note) The value is for manifold base with stations and individually operated position type. C, N, 0 C, C0, C N9, N, 0, 0 Cv nclosure of Manifold Variations (Common for cassette base and tie-rod base) X00 ecentralized serial wiring X0 Serial wiring with input/output onit X0 edicated output serial wiring For circular connector -sub connector Flat ribbon cable nclosure of a gateway unit and input manifold is I6. -- nclosure (ased on IC9) I67 I67 usttight (I0) I67 usttight (I0) usttight (I0)

2 ecentralized Serial Wiring I67 compliant X00 J Tie-rod base Cassette base pplicable series Cassette base manifold / Tie-rod base manifold /// Number of output points: 6 points X00 gateway unit communication specifications Remote I/O, evicenet, ROFIS- --7

3 X00 ecentralized Serial Wiring For details about certified products conforming to international standards, visit us at Tie-rod base SSV Cassette base W 0S W How to Order SSV W 6S W 0 Mounting irect mounting IN rail mounting (With IN rail) IN rail mounting (Without IN rail) For stations When a longer IN rail is desired than the specified stations. (Specify a For 6 stations longer rail than the standard length.) In the case of 0, only IN rail fittings are attached. Valve stations Symbol Stations stations stations stations 6 stations W W 0 Note ouble wiring specifications nclosure I67 specifications SI unit () Specified layout (up to 6 solenoids possible.) For Remote I/O For evicenet/ For rofius- Without SI unit () Note ) ouble wiring specifications: Single, double, position and position solenoid valves can be used on all manifold stations. se of a single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note ) Specified layout: Indicate wiring specifications on the manifold specification sheet. (Note that double, position and position valves cannot be used where single solenoid wiring has been specified.) IN rail length specified Standard length For stations (Specify a longer rail than the standard 6 For 6 stations length.), port location side ( to 0 stations) side ( to 0 stations) oth sides ( to 6 stations) S/XH block assembly specifications S R RS Internal pilot Internal pilot/uilt-in silencer xternal pilot xternal pilot/uilt-in silencer Note) When the built-in silencer type is used, keep the exhaust port from coming in direct contact with water or other liquids., port size (metric) Symbol, port C C C6 C C6 C C6 fitting for ø. fitting for ø fitting for ø6 fitting for ø fitting for ø6 fitting for ø fitting for ø6 C fitting for ø In the case of mixed C0 fitting for ø0 specifications (M), indicate separately on the manifold C fitting for ø specification sheet. C0 fitting for ø0 ort sizes of X, port for external pilot C 0 fitting for ø Rc / specifications (R, RS) are 0 Rc/ ø (metric), ø/" (inch) 0F G / for /000 and ø6 (metric) and ø/" (inch) 0F G / for /000. M, ports mixed --0, port pplicable series fitting for ø fitting for ø0 fitting ø fitting ø Rc / G /, port size (inch) Symbol N N N7 N N7 N9 N7 N9 N N9 N 0N 0N 0T 0T M, port fitting for ø/" fitting for ø/" fitting for ø/" fitting for ø/" fitting for ø/" fitting for ø/6" fitting for ø/" fitting for ø/6" fitting for ø/" fitting for ø/6" fitting for ø/" NT / NT / NTF / NTF /, ports mixed, port pplicable series fitting for ø/6" fitting for ø/" fitting for ø/" fitting for ø/" NT / NTF /

4 side X00 ecentralized Serial Wiring How to Order Valve Manifold ssembly Ordering example () Manifold SSV-W6SW-06-C6 ( set) ouble solenoid 00-F ( sets) Single solenoid 00-F ( sets) side WR COM SSV-W6SW-06-C6 set (Manifold part no.) 00-F sets (Single solenoid part no.) 00-F sets (ouble solenoid part no.) Stations J How to Order Solenoid Valves 00 F Note) Note) vailable with manifold block for station additions. Refer to pages --9 and --9. Manual override : Non-locking push type : ush-turn locking slotted type Type of actuation position single solenoid position double solenoid position closed center position exhaust center position pressure center position dual port valve: N.C./N.C. position dual port valve: N.O./N.O. position dual port valve: N.C./N.O. C position dual port valves are applicable to 000 and only. ilot type Internal pilot R xternal pilot xternal pilot specifications is not available for position dual port valves. ack pressure check valve K uilt-in uilt-in back pressure check valve type is applicable to series only. ack pressure check valve is not available for position closed center and position pressure Rated voltage VC Light/Surge voltage suppressor R With light/surge voltage suppressor With surge voltage suppressor Refer to recautions on page

5 X00 ecentralized Serial Wiring imensions: 000 for X00 ecentralized Serial Wiring C6, N7 C, N9 C0, N Tie-rod base manifold: SSV-W0S W- Stations (S, R, RS) - (-) When, port outlets are indicated on the side or side, the, ports on the opposite side are plugged. xternal pilot port positions and silencer discharge port positions are the same as, port outlet positions.. 6. fitting [(), /() port] pplicable tubing O..: ø ø/" IN rail holding screw (For IN rail mounting) side 6.. (.) (itch) = 0. L L. -M fitting [(), () port] pplicable tubing O..: ø6, ø/" ø, ø/6" ø0, ø/" side (L) (.).6.6 C C With xternal ilot Specifications fitting [X: xternal pilot port] pplicable tubing O..: ø6 ø/" X X fitting [: ilot XH port] pplicable tubing O..: ø6 ø/" C C J SI unit ø. (For mounting) Light/Surge voltage suppressor Manual override (ress and turn for the locking type.) () port side: Orange () port side: Green L (Rail mounting hole pitch:.) L (Station n) (Station ) WR COM Silencer (ir discharge port) (uilt-in silencer specifications) With option 0.. / / Individual S spacer Individual XH spacer Interface regulator -M- Interface regulator -00- MX..7 (For IN rail mounting) (0) L imension L n L L L L L n: Stations

6 Serial Wiring with Input/Output nit I67 compliant X0 J Tie-rod base pplicable series Tie-rod base manifold // Number of inputs/outputs: each --

7 X0 Serial Wiring with Input/Output nit For details about certified products conforming to international standards, visit us at Tie-rod base nclosure I67 specifications How to Order SSV W0S QW 0 SI unit QW 0 For evicenet Without SI unit Input blocks cannot be mounted without SI unit. When the IN rail is included without an SI unit, the IN rail length will accommodate an SI unit and one input block. Input block type Without input block M: inputs M: inputs M: inputs ( pins) Note) Without SI unit, the symbol is nil. Input block stations station stations Note) Without SI unit, the symbol is nil. Input block common specifications N +COM COM 0 0 Mounting irect mounting IN rail mounting (With IN rail) IN rail mounting (Without IN rail) For stations When a longer IN rail is desired than the specified stations. (Specify a longer For 0 stations rail than the standard length.) In the case of 0,only IN rail fittings are attached. Valve stations Symbol Stations stations 6 stations stations 0 stations Note ouble wiring specifications () () Specified layout (up to solenoids possible.) Note ) ouble wiring specifications: Single, double, position and position solenoid valves can be used on all manifold stations. se of a single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note ) Specified layout: Indicate wiring specifications on the manifold specification sheet. (Note that double and position valves cannot be used where single solenoid wiring has been specified.), port location side ( to 0 stations) side ( to 0 stations) oth sides ( to 0 stations) S/XH block assembly specifications Internal pilot S Internal pilot/uilt-in silencer R xternal pilot RS xternal pilot/uilt-in silencer Note) When the built-in silencer type is used, keep the exhaust port from coming in direct contact with water or other liquids. --6, port size (metric) Symbol, port C fitting for ø. C fitting for ø C6 fitting for ø6 C fitting for ø C6 fitting for ø6 C fitting for ø C6 fitting for ø6 C fitting for ø C0, port pplicable series fitting for ø fitting for ø0, port size (inch) Symbol, port N fitting for ø/" N fitting for ø/" N7 fitting for ø/" N fitting for ø/" N7 fitting for ø/" N9 fitting for ø/6" N7 fitting for ø/" N9 fitting for ø/6" N fitting for ø/", port pplicable series fitting for ø/6" fitting for ø/" fitting for ø fitting for ø/" fitting for ø0 M, ports mixed M, ports mixed In the case of mixed specifications (M), indicate separately on the manifold specification sheet. ort sizes of X, port for external pilot specifications (R, RS) are ø (metric), ø/" (inch) for /000 and ø6(metric) and ø/" (inch) for /000.

8 side X0 Serial Wiring with Input/Output nit How to Order Valve Manifold ssembly Ordering example () Manifold SSV-W0SQWN-0-C6 ( set) side Stations ouble solenoid 00-F ( sets) Single solenoid 00-F ( sets) Input block (M: inputs, station) SSV-W0SQWN-0-C6 set (manifold part no.) 00-F sets (Single solenoid part no.) 00-F sets (ouble solenoid part no.) J How to Order Solenoid Valves 00 F Note) Note) vailable with manifold block for station additions. Refer to page --9. Manual override : Non-locking push type : ush-turn locking slotted type Type of actuation position single solenoid position double solenoid position closed center position exhaust center position pressure center position dual port valve: N.C./N.C. position dual port valve: N.O./N.O. C position dual port valve: N.C./N.O. position dual port valves are applicable to 000 and only. ilot type Internal pilot R xternal pilot xternal pilot specifications is not available for position dual port valves. Rated voltage VC Light/Surge voltage suppressor R With light/surge voltage suppressor With surge voltage suppressor ack pressure check valve K uilt-in uilt-in back pressure check valve type is applicable to series only. ack pressure check valve is not available for position closed center and position pressure center. Refer to recautions on page

9 X0 Serial Wiring with Input/Output nit pplicable network: evicenet The serial transmission system reduces wiring work, while minimizing wiring and saving space. /000/000 evicenet compatible SI unit s a evicenet slave unit, it is capable of solenoid valve ON/OFF control up to a maximum of points. In addition, by connecting an input block a maximum of sensor signal inputs are possible. Input block This is an expansion block which connects to an SI unit to perform sensor input from auto switches, etc. Two or four sensor inputs can be accommodated by one input block, and the common can be matched to the sensor by an NN/N switch. Note) Input connectors are available in both M and M types. Note) COM is set at the shipment. lease contact SMC for alteration after shipment. etails in connector Input connector: M pins (socket) Cable side connector example: OMRON Corporation: XSG input block (X0-I) No. escription Function SW+ N.C (SIGNL) SW SIGNL Sensor power supply + Open Sensor power supply Sensor input signal Sensor ground In the case of a input block (X0-I), this is the sensor input signal. Communication connector: M... pins (socket) xample of corresponding cable assemblies with connector: OMRON Corporation: C-CN0F Karl Lumberg GmbH & Co. KG: RKT-6 No. escription rain V+ V CN_H CN_L Function rain/shield Circuit power supply + Circuit power supply Signal H Signal L S WR / Indicator unit (L) descriptions and functions SI unit Input block Input connector: M pins (socket) Cable side connector example: Franz inder GmbH: 7, 76 series No. escription Function V Sensor power supply + 0V Sensor power supply IN Sensor input signal WR(V) WR MO/NT 6 STTINGS WR 6 X0 escription WR(V) WR MO/NT escription WR 0 to ower connector: M pins (plug) (boss configuration differs from communication connector) xample of corresponding cable assemblies with connector: Hans Turck FmbH & Co. KG: WKW. T- No. escription V 0V SWV SW0V Function Function For solenoid valve + V For solenoid valve For input block + V For input block Ground ON when solenoid valve power supply is turned ON ON when evicenet circuit power supply input is turned ON OFF: ower supply off, on line, or when checking duplication of MC_I Green blinking: Waiting for connection (On line) Green ON: Connection established (On line) Red blinking: Connection time out (Minor communication abnormality occurs) Red ON: MC_I duplication error, or SOFF error (Major communication abnormality occurs) Weight Function escription weight (g) ON when sensor power is turned ON SI unit ON when each sensor input goes ON Input block nd plate assembly 0 For parts composition, refer to page X0 --

10 X0 Serial Wiring with Input/Output nit imensions: 000 for X0 Serial Wiring with Input/Output nit Tie-rod base manifold: SSV-W0S - Stations (With input blocks) (S, R, RS) - C6, N7 C, N9 C0, N (-) When, port outlets are indicated on the side or side, the, ports on the opposite side are plugged. xternal pilot port positions and silencer discharge port positions are the same as, port outlet positions fitting [(), /() port] pplicable tubing O..: ø ø/" IN rail holding screw (For IN rail mounting) ø. (For mounting) side (itch).. = 0. (.) Ground terminal -M fitting -M [(), () port] pplicable tubing O..: ø6, ø/" ø, ø/6" ø0, ø/" Silencer (ir discharge port) (uilt-in silencer specifications) L (L) side L6 L7. IN rail holding screw (For IN rail mounting) SI unit Input block (.) Manual override ress and turn for the ( locking type. ) () port side: Orange () port side: Green L 6 L (Rail mounting hole pitch:.) L T WR S With xternal ilot Specifications fitting [X: xternal pilot port] pplicable tubing O..: ø6 nd plate assembly -M mounting hole X X With option WR S 6 fitting [: ilot XH port] pplicable tubing O..: ø6 ø/" ø/" T 6 J (Station n) (Station ) Light/Surge voltage suppressor (Station ) (Station n) 0.. / / Individual S spacer Individual XH spacer Interface regulator -M- Interface regulator -00- MX. L: IN Rail Overall Length Valve stations (n) Input block Stations(n) (For IN rail mounting) L = L 0. L = 0. x n L = L + + x n L = (L L)/ L6 = 0. x n + 6 L7 = x n (0) n = Valve stations n = Input block stations (mm)

11 edicated Output Serial Wiring X0 J Tie-rod base Cassette base pplicable series Cassette base manifold / Tie-rod base manifold /// Number of outputs points: 6 points --

12 X0 edicated Output Serial Wiring For details about certified products conforming to international standards, visit us at Tie-rod base Cassette base SI unit C F G H J J K Q R R V SSV How to Order SSV 6S 0 Symbol Specifications 0 Without SI unit With general type SI unit ( X00) Mitsubishi lectric Corp.: MLSCNT/MINI-S ata Link System OMRON Corp.: SS Wire System SHR Corp.: Satellite I/O Link System Matsushita lectric Works: MWNT-F System NK Corp.: ni-wire System (6 output points) For the general purpose type, a transmission unit is require on the C side. -- Rockwell utomation: llen radley Remote I/O (RIO) System NK Corp.: ni-wire H System SNX Corp.: S-LINK System (6 output points) SNX Corp.: S-LINK System ( output points) Fuji lectric Co.: T-LINK Mini System evicenet, Compous/ (OMRON Corp.) OMRON Corp.: Compous/S System (6 output points) OMRON Corp.: Compous/S System ( output points) JMNT (JCN-) Mitsubishi lectric Corp.: CC-LINK System SI nit art No. Valve stations Symbol Stations Note 0 stations () ouble wiring specifications 0 stations 0 stations () Specified layout 6 6 stations (up to 6 solenoids possible.) Since J and R type SI units have outputs note that up to solenoids can be accommodated. This also includes the number of blanking plate assemblies. Note ) ouble wiring specifications: Single, double, position and position solenoid valves can be used on all manifold stations. se of a single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note ) Specified layout: Indicate wiring specifications on the manifold specification sheet. (Note that double and position valves cannot be used where single solenoid wiring has been specified.), port location 0S 0 side ( to 0 stations) side ( to 0 stations) oth sides ( to 6 stations) Mounting 0 irect mounting IN rail mounting (With IN rail) IN rail mounting (Without IN rail) For stations When a longer IN rail is desired than the specified stations. (Specify a 6 For 6 stations longer rail than the standard length.) IN rail length specified Standard length For stations (Specify a longer rail than the standard 6 For 6 stations length.) S/XH block assembly specifications S R RS Internal pilot Internal pilot/uilt-in silencer xternal pilot xternal pilot/uilt-in silencer Symbol Specifications With general type SI unit ( X00) For SSV - S X0-S00 Symbol H Specifications NK Corp.: ni-wire H System Mitsubishi lectric Corp.: J SNX Corp.: S-LINK System (6 output points) X0-SM MLSCNT/MINI-S ata Link System J SNX Corp.: S-LINK System ( output points) C F OMRON Corp.: SS Wire System SHR Corp.: Satellite I/O Link System Matsushita lectric Works: MWNT-F System NK Corp.: ni-wire System (6 output points) X0-ST X0-SSH X0-S X0-SW K Q R R Fuji lectric Co.: T-LINK Mini System evicenet, Compous/ (OMRON Corp.) OMRON Corp.: Compous/S System (6 output points) OMRON Corp.: Compous/S System ( output points) G Rockwell utomation: JMNT (JCN-) X0-S llen radley Remote I/O (RIO) System V Mitsubishi lectric Corp.: CC-LINK System For terminal L descriptions for each SI unit and cable wiring, etc., refer to pages --6 to --. In the case of 0, only IN rail fittings are attached. For SSV - S X0-SH X0-SSL X0-SSL X0-SF X0-SN X0-SCS X0-SCS X0-SJN X0-SMJ

13 X0 edicated Output Serial Wiring How to Order Valve Manifold ssembly Ordering example () Manifold SSV-6S-06-C6 ( set) ouble solenoid 00-F ( sets) Single solenoid 00-F ( sets) side Stations 00 Type of actuation position single solenoid position double solenoid position closed center position exhaust center position pressure center position dual port valve: N.C./N.C. position dual port valve: N.O./N.O. C position dual port valve: N.C./N.O. position dual port valves are applicable to 000 and only. side ilot type Internal pilot R xternal pilot xternal pilot specifications is not available for position dual port valves. How to Order Solenoid Valves SSV-6S-06-C6 set (manifold part no.) 00-F sets (Single solenoid part no.) 00-F sets (ouble solenoid part no.) F Rated voltage VC ack pressure check valve Note) vailable with manifold block for station additions. Refer to pages --9 and --9. Manual override : Non-locking push type : ush-turn locking slotted type Light/Surge voltage suppressor R With light/surge voltage suppressor With surge voltage suppressor K uilt-in uilt-in back pressure check valve type is applicable to 000 only. ack pressure check valve is not available for position closed center and position pressure center. Refer to recautions on page --9. Note) J, port size (Metric) Symbol, port C fitting for ø. C fitting for ø C6 fitting for ø6 C fitting for ø C6 fitting for ø6 C fitting for ø C6 fitting for ø6 C fitting for ø C0 fitting for ø0 C fitting for ø C0 fitting for ø0 C fitting for ø 0 Rc / 0 Rc / 0F G / 0F G /, port pplicable series fitting for ø fitting for ø0 fitting for ø fitting for ø Rc / G /, port size (Inch) Symbol N N N7 N N7 N9 N7 N9 N N9 N 0N 0N 0T 0T M, port fitting for ø/" fitting for ø/" fitting for ø/" fitting for ø/" fitting for ø/" fitting for ø/6" fitting for ø/" fitting for ø/6" fitting for ø/" fitting for ø/6" fitting for ø/" NT / NT / NTF / NTF /, port pplicable series fitting for ø/6" fitting for ø/" fitting for ø/" fitting for ø/" NT / NTF /, ports mixed M, ports mixed In the case of mixed specifications (M), indicate separately on the manifold specification sheet. ort sizes of X, port for external pilot specification (R, RS) are ø (metric), ø/" (inch) for /000 and ø6 (metric) and ø/" (inch) for /

14 The serial transmission system reduces wiring work, while minimizing wiring and saving space. Maximum 6 stations (Specify a model with more than 9 stations by means of the manifold specification sheet.) Type X00 Type Mitsubishi lectric Corporation MLSCNT/MINI-S ata Link System STTION NO. side Stations side Stations are counted from side as the st. maximum of 6 solenoids is possible (6 stations with single solenoids). Item Specifications xternal power supply VC + 0%/ %,,,, F, G, J, Current consumption 0. J, K, R, R, H,, V (Internal unit) 0. C, Q Name of terminal block, L Note V S S SG R R L TR RN/RR RN RR TR RSS NO. escription ON during data reception links for normal data reception, ON for abnormal Connection to T unit LC manufacturer s I/O card enables serial transmission. X00-TM for Mitsubishi lectric Corporation X00-TT for OMRON Corporation X00-TF for Fuji lectric Co., Ltd. X00-T00 General purpose ach T unit has control points. No. of output points, 6 points L OWR RN R S RR OWRRNS R RR x 0 x V S S SG R R escription ON for power supply input ON for normal data traffic with master unit ON during data reception ON during data transmission ON for data reception error, OFF when normal MLSCNT/MINI-S ata Link System Master unit : J7T-S J7T-S SJ7T-S No. of output points, 6 points, No. of stations. occupied, stations SI manifold solenoid valve T unit O unit SI unit SI unit Master unit Remote I/O unit Remote I/O unit Cable wiring S S SG V S S R R SG V S S R R SG V S S R R SG V S S R R SG S S R R SG S S R R SG Ground either the reception side or the transmission side of the shielding wire shield. Ground either the reception side or the transmission side of the shielding wire shield. Type C OMRON Corporation SS Wire System Type SHR Corporation Satellite I/O Link System Type Matsushita lectric Works, Ltd. MWNT-F System Name of terminal block, L L RN T/R RR RN T/R RR 6 I SW. V escription ON when transmission is normal and LC is in operation mode links when transmission is normal, ON when transmission is abnormal. L OWR RN RR R.ST HOL OWR RN RR R.ST HOL RSS NO. TRM. V L L SG L L V escription ON when power supply is ON ON when power is ON and slave unit operates normally ON for abnormal slave unit switch setting, abnormal communication, master unit LC stopped and defective slave unit ON for master unit control input L OWR COMM. LRM OWR COMM. LRM STSTION NO. TRM. x 0 x OFF ON escription ON when power supply is ON links during data transmission/reception ON for unit abnormality, blinks for station no. setting error Note SS Wire System Master unit : Type C00-RM0 Type C00H-RM0 No. of output points, 6 points Satellite I/O Link System JW-LM, JW-LMH Master unit : ZW-LM JW-LM, JW-LMH No. of output points, 6 points MWNT-F System Master unit : F70, F7 F70, F7 No. of output points, 6 points Master unit SI unit SI unit a) -wire type Wiring does not include signal ground line (SG). ZW-LM Master unit Slave unit 0 Slave unit 0 Slave unit 7 L L L L Master unit SI unit SI unit Cable wiring V Type ground + + V Type ground L L SG SG SHIL SHIL Twisted pair wire with shield L L SG SG SHIL SHIL Type ground Type ground Type ground Type ground b) -wire type Wiring does not include signal ground line (SG). ZW-LM Master unit Slave unit 0 Slave unit 0 Slave unit 7 L L L L L L L L SG SG SG SG SHIL SHIL SHIL SHIL Twisted pair wire with shield Type ground Type ground Type ground Type ground V Type ground + + V Type ground --6

15 X0 edicated Output Serial Wiring Type F NK Corporation ni-wire System Type G Rockwell utomation, Inc. llen radley Remote I/O (RIO) System Type J, J SNX Corporation S-LINK System Name of terminal block, L Note L OWR SN OWR V G G V V L L SHIL L L G V G V ni-wire System Send unit : S-0 SN RSS escription ON for power supply input (ON when normal, flickers when voltage drops) Transmission indication: links when normal, OFF or ON when abnormal No. of output points, 6 points ON OFF L OWR COM RROR OWR SN escription ON when power supply is ON ON when communication is normal links when communication is initialized OFF for abnormal communication ON for abnormal communication Remote I/O (RIO) System RSS No. of output points, 6 points ON OFF L OWR SN OWR SN escription ON for power supply input Transmission indication: links when normal, links slowly when abnormal S-LINK System S-LINK controller: SL-C I SW. No. of output points, 6 points (Type J) No. of output points, points (Type J) 6 J Cable wiring Transmission line G ower supply ower supply V V ower supply V ower supply V V G G V V G G V Master unit LIN LIN SHIL SI unit L L SHIL L L V Type ground SI unit L L SHIL L L V Type ground Terminal resistor a) Type T branching multi-drop wiring (S-LINK System) lack White G Main transmission line V G V rown lue Crimped connector SL-J b) Crossover wiring (Sensor Link System) G0V V G0V V Transmission line G The above is the example of using dedicated S-LINK flat ribbon cable SL-RCMl00. Type K Fuji lectric Co., Ltd. T-LINK Mini System Type Q evicenet Type R, R OMRON Corporation Compous/S STTION NO. WR MO/NT STTINGS Name of terminal block, L L L OWR LM OWR LM TRM. x 0 x ON OFF V 0V S S S S S escription ON for power supply input ON for abnormal transmission or processor side power supply cut L WR MO/ NT 6 V V- CNL CNH V+ escription Green light ON for evicenet circuit power input OFF When this unit is off line or circuit power is OFF Green blinks When waiting for connection (On line) Green ON When connection is established (On line) Red blinks Red ON When connection time out occurs (recoverable communication abnormality) For MC I duplication error, or SOFF error (major communication abnormality) L WR COMM RR WR RSS NO. COMM RR 6 S+ H L S- V escription ON when communication power is supplied, OFF when power is OFF ON for normal communication, OFF for abnormal communication or waiting ON for abnormal communication, OFF for normal communication or waiting Note T-LINK Mini System Master unit : FTM00 Converter : FRC00-G0 Repeater : FRC00-C0 No. of output points, 6 points evicenet OMRON Corporation: Compous/ System Master unit : Type C00HW-RM-V Master unit : Type CSW-RM No. of output points, 6 points Compous/S System Master unit : Type C00HW-SRM-V Master unit : Type CQM-SRM-V No. of output points, 6 points (Type SR) No. of output points, points (Type SR) V V CNL CNH V + V V CNL CNH V + S + H L S V S + H L S V Cable wiring Master unit Slave unit 0 Slave unit 0 Slave unit 7 S S S S S S S S S S S S Twisted pair wire with shield Type ground Type ground Type ground Type ground Connect the shielding wire to the S terminal. If the shielding wire is not connected to the S terminal, normal transmission will be impossible even for short distances. Furthermore, do not ground the shielding wire (S). V CNL CNH V + Master H L Connector with terminal resistor ranch crimped connectors --7

16 6 7 O N Type H NK Corporation ni-wire H System Type JMNT (JCN-) Type V Mitsubishi lectric Corporation CC-LINK System Name of terminal block, L L OWR SN OWR SN ON OFF RSS V 0V G G V 0V escription ON for power supply input (ON when normal, flickers when voltage drops) Transmission indication: links when normal, OFF or ON when abnormal L OWR COMM LRM OWRCOMM LRM V 0V SG V 0V ON I.SW 6 escription ON for SI unit power supply input On for normal communication ON for abnormal communication L W L RN S R L RR. LRR. W S LRN R RT STTION NO. 6 6 V 0V +V G G escription ON when communication power is supplied, OFF when power is OFF ON when normal data is being received ON when data is transmitted ON when data is received ON for transmission error/wrong setting, links when station or transmission speed setting changes during operation 9 6 x 0 x Note ni-wire H System Send unit: S-H No. of output points, 6 points JMNT (JCN-) (Reference) J7J9-S (Mitsubishi lectric Corporation) SJ7J9-S (Mitsubishi lectric Corporation) Type C00HW-JRM (OMRON Corporation) NJ-JCN- (Fuji lectric Co., Ltd.) NL-J (Fuji lectric Co., Ltd.) No. of output points, 6 points CC-Link System Master unit : J6T Master unit : SJ6T Master unit : J6QT Master unit : SJ6QT No. of output points, 6 points G a) -wire type Cable wiring Transmission line ower supply ower supply ower supply ower supply V V V V V G G V V G G V Master station SG b) -wire type Master station SG Slave unit (S unit) SG Twisted pair wire with shield Slave unit (S unit) SG Twisted pair wire with shield Slave unit (S unit) SG Slave unit (S unit) SG Slave unit (S unit) SG Slave unit (S unit) SG Terminal resistor Master unit SI unit SI unit G G G SL Twisted pair wire with shield Type ground Type ground Terminal resistor Type ground G --

17 X0 edicated Output Serial Wiring imensions: 000 for X0 edicated Output Serial Wiring Tie-rod base manifold: SSV-0S - Stations (S, R, RS) - C6, N7 C, N9 C0, N (-) When, port outlets are indicated on the side or side, the, ports on the opposite side are plugged. xternal pilot port positions and silencer discharge port positions are the same as, port outlet positions fitting [(), /() port] pplicable tubing O..: ø ø/" side IN rail holding screw (For IN rail mounting) (itch).. = 0. (.) fitting [(), () port] pplicable tubing O..: ø6, ø/" ø, ø/6" ø0, ø/" L. L (.) side (L) With xternal ilot Specifications fitting [X: xternal pilot port] pplicable tubing O..: ø6 ø/" X fitting [: ilot XH port] pplicable tubing O..: ø6 ø/" X J M Terminal screw 6. -ø. (For mounting) Light/Surge voltage suppressor.7 6. Manual override ress and turn for the ( locking type. ) () port side: Orange () port side: Green L (Rail mounting hole pitch:.) L (Station n) (Station ) 77.. Silencer (ir discharge port) (uilt-in silencer specifications) With option 0.. / Individual S spacer Individual XH spacer / Interface regulator -M Interface regulator -00- MX..7 (For IN rail mounting) (0) L imension L n L L L L L n: Stations Note) The width of type (Matsushita lectric Works, Ltd.) and type G (Rockwell utomation, Inc.) SI units are. mm greater. For details, please contact SMC. --

18 Circular Connector I67 compliant J Tie-rod base Cassette base pplicable series Cassette base manifold / Tie-rod base manifold /// Number of connectors: 6 pins --

19 For details about certified products conforming to international standards, visit us at Circular Connector Tie-rod base SSV Cassette base --6 W SSV W 6C 0 Valve stations Type 6: 000 Symbol Stations stations 9 stations stations nclosure I67 specifications Note ouble wiring specifications () Specified layout () (up to solenoids possible.) stations Type 6: 000 Symbol Stations Note 0 stations 0 0 How to Order ouble wiring specifications () stations stations Specified layout () 0 stations (up to solenoids possible.) Note ) ouble wiring specifications: Single, double, position and position solenoid valves can be used at all of the manifold stations. se of a single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note ) Specified layout: Indicate wiring specifications on the manifold specification sheet. (Note that double, and position valves cannot be used where single solenoid wiring has been specified.), port location side ( to 0 stations) side ( to 0 stations) oth sides ( to 0 stations) S/XH block assembly specifications S R RS Symbol 0 0 Stations stations stations 0 stations 0 stations Valve stations Note () ouble wiring specifications () Specified layout (p to solenoids possible.) 0C Internal pilot Internal pilot/uilt-in silencer xternal pilot xternal pilot/uilt-in silencer 0 Note) When the built-in silencer type is used, keep the exhaust port from coming in direct contact with water or other liquids. Note ) ouble wiring specifications: Single, double, position and position solenoid valves can be used at all of the manifold stations. se of a single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note ) Specified layout: Indicate wiring specifications on the manifold specification sheet. (Note that double, and position valves cannot be used where single solenoid wiring has been specified.) Mounting 0 0 irect mounting IN rail mounting (With IN rail) IN rail mounting (Without IN rail) For stations When a longer IN rail is desired than the specified stations. (Specify a longer rail than the For 0 stations standard length.) In the case of 0, only IN rail fittings are attached. IN rail length specified Standard length For stations (Specify a longer rail than the standard length.) 0 Note) For 0 stations Note) ble to specify the length for stations up to stations for, which is available with station at the maximum., port size (Metric) Symbol Specifications, port pplicable series C fitting for ø. C fitting for ø fitting for ø C6 fitting for ø6 C fitting for ø C6 fitting for ø6 fitting for ø0 C fitting for ø C6 fitting for ø6 C fitting for ø fitting for ø C0 fitting for ø0 C fitting for ø C0 fitting for ø0 fitting for ø C fitting for ø 0 Rc / Rc / 0 Rc / 0F G / 0F G / G / M, ports mixed, port size (Inch) Symbol Specifications, port pplicable series N fitting for ø/" N fitting for ø/" fitting for ø/6" N7 fitting for ø/" N fitting for ø/" N7 fitting for ø/" fitting for ø/" N9 fitting for ø/6" N7 fitting for ø/" N9 fitting for ø/6" fitting for ø/" N fitting for ø/" N9 fitting for ø/6" N fitting for ø/" fitting for ø/" 0N NT / NT / 0N NT / 0T NTF / NTF / 0T NTF / M, ports mixed In the case of mixed specifications (M), indicate separately on the manifold specification sheet. ort sizes of X, port for external pilot specification (R, RS) are ø(metric), ø/"(inch) for /000 and ø6 (metric) and ø/"(inch) for /000.

20 side Circular Connector How to Order Valve Manifold ssembly Ordering example () Manifold SSV-W6C-06-C6 ( set) ouble solenoid 00-F ( sets) side Stations Single solenoid 00-F ( sets) SSV-W6C-06-C6 set (manifold part no.) 00-F sets (Single solenoid part no.) 00-F sets (ouble solenoid part no.) J How to Order Solenoid Valves 00 F Note) Note) vailable with manifold block for station additions. Refer to pages --9 and --9. Manual override : Non-locking push type : ush-turn locking slotted type Type of actuation position single solenoid position double solenoid position closed center position exhaust center position pressure center position dual port valve: N.C./N.C. position dual port valve: N.O./N.O. C position dual port valve: N.C./N.O. position dual port valves are applicable to 000 and only. R ilot type Internal pilot xternal pilot xternal pilot specifications is not available for position dual port valves. ack pressure check valve K uilt-in uilt-in back pressure check valve type is applicable to series only. ack pressure check valve is not available for position closed center and position pressure center. Rated voltage 6 VC VC Light/Surge voltage suppressor R With light/surge voltage suppressor With surge voltage suppressor Refer to recautions on page

21 Manifold lectrical Wiring 0C/6C Circular Connector Type Common Common! q!!6 e! r! t!0 y o i u Light/Surge voltage suppressor Light/Surge voltage suppressor Light/Surge voltage suppressor Light/Surge r e w q SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. Station Station Station Station This circuit has double wiring specifications for up to stations. Since the usable number of solenoids differs depending on the manifold type, refer to the table below. In the case of single solenoids, connect to SOL.. Furthermore, when wiring is specified on a manifold specification sheet, connections are made without skipping any connectors, and connections are made without skipping any connectors, and signals for single and, for double are in order, etc. Stations are counted from side (connector side) as the st. Since solenoid valves do not have polarity, either the +COM or COM can be used. sable No. of Solenoids Model Tie-rod base type 0 Cassette base type 6 to Max. no. of solenoids --

22 9 7 6 Circular Connector imensions: 000 for Circular Connector Stations Tie-rod base manifold: SSV-W0C- (S, R, RS) - C6, N7 C, N9 C0, N (-) When, port outlets are indicated on the side or side, the, ports on the opposite side are plugged. xternal pilot port positions and silencer discharge port positions are the same as, port outlet positions. With xternal ilot Specifications..6. (itch) = fitting [(), /() port] pplicable tubing O..: ø ø/" side IN rail holding screw (For IN rail mounting) (.) L L. fitting [(), () port] pplicable tubing O..: ø6, ø/" ø, ø/6" ø0, ø/" (.) (L) side fitting [X: xternal pilot port] pplicable tubing O..: ø6 ø/" X fitting [: ilot XH port] pplicable tubing O..: ø6 ø/" X J ø. (For mounting) Manual override ress and turn for the ( locking type. ) () port side: Orange () port side: Green L (Rail mounting hole pitch:.) L 0. Silencer (ir discharge port) (uilt-in silencer specifications). Notch (To align connector position) With option (Station n) (Station ) Light/Surge voltage suppressor (Cable assembly) Min. bending radius 0 mm 0.. / / (For IN rail mounting) (0) () (When circular connector is mounted) Individual S spacer Individual XH spacer Interface regulator -M- Interface regulator MX. L imension L n L L L L L n: Stations

23 -sub Connector J Tie-rod base Cassette base pplicable series Cassette base manifold / Tie-rod base manifold /// Number of connectors: pins MIL-C-0 Conforming to JIS-X-0 --6

24 For details about certified products conforming to international standards, visit us at Tie-rod base Cassette base Valve stations 000 Symbol Symbol 0 0 Stations stations 9 stations stations stations Stations stations stations 0 stations 0 stations sub Connector SSV 0F How to Order Valve stations Symbol 0 0 Stations stations stations 0 stations 0 stations SSV 6F 0 Note () ouble wiring specifications Specified layout () (p to solenoids possible.) Note () ouble wiring specifications () Specified layout (p to solenoids possible.) Connector entry direction pward Lateral ilot type Note () ouble wiring specifications () Specified layout (p to solenoids possible.) Note ) ouble wiring specifications: Single, double, position and position solenoid valves can be used at all of the manifold stations. se of a single solenoid will result in an unused control signal in an unused control signal. If this is not desired, order with a specified layout. Note ) Specified layout: Indicate wiring specifications on the manifold specification sheet. (Note that double, and position valves cannot be used where single solenoid wiring has been specified.), port location S R RS, port size (metric) Symbol, port C fitting for ø. C fitting for ø C6 fitting for ø6 C fitting for ø C6 fitting for ø6 C fitting for ø C6 fitting for ø6 C fitting for ø C0 fitting for ø0 C fitting for ø C0 fitting for ø0 C fitting for ø 0 Rc / 0 Rc / 0F G / 0F G / M 0 side ( to 0 stations) side ( to 0 stations) oth sides ( to 0 stations) Internal pilot Internal pilot/uilt-in silencer xternal pilot xternal pilot/uilt-in silencer, port pplicable series fitting for ø fitting for ø0 fitting for ø fitting for ø Rc / G /, ports mixed Note ) ouble wiring specifications: Single, double, position and position solenoid valves can be used at all of the manifold stations. se of a single solenoid will result in an unused control signal in an unused control signal. If this is not desired, order with a specified layout. Note ) Specified layout: Indicate wiring specifications on the manifold specification sheet. (Note that double, and position valves cannot be used where single solenoid wiring has been specified.) Mounting IN rail length specified Standard length For stations (Specify a longer rail than the standard 0 Note) For 0 stations length.) Note) ble to specify the length for stations up to stations for, which is available with stations at the maximum. 0 0 irect mounting IN rail mounting (With IN rail) IN rail mounting (Without IN rail) For stations For 0 stations, port size (inch) Symbol, port N fitting for ø/" N fitting for ø/" N7 fitting for ø/" N fitting for ø/" N7 fitting for ø/" N9 fitting for ø/6" N7 fitting for ø/" N9 fitting for ø/6" N fitting for ø/" N9 fitting for ø/6" N fitting for ø/" 0N NT / 0N NT / 0T NTF / 0T NTF / M, port pplicable series fitting for ø/6" fitting for ø/" fitting for ø/" fitting for ø/" NT / NTF / When a longer IN rail is desired than the specified stations. (Specify a longer rail than the standard In case of 0, only IN rail fittings are attached., ports mixed In the case of mixed specifications (M), indicate separately on the manifold specification sheet. ort sizes of X, port for external pilot specifications (R, RS) are ø (metric), ø/" (inch) for /000 and ø6 (metric) and ø/" (inch) for /000.

25 side -sub Connector How to Order Valve Manifold ssembly Ordering example () Manifold SSV-6F-06-C6 ( set) ouble solenoid 00-F ( sets) Single solenoid 00-F ( sets) side SSV-6F-06-C6 set (manifold part no.) 00-F sets (Single solenoid part no.) 00-F sets (ouble solenoid part no.) Stations J How to Order Solenoid Valves 00 F Note) Note) vailable with manifold block for station additions. Refer to pages --9 and --9. Manual override : Non-locking push type : ush-turn locking slotted type Type of actuation position single solenoid position double solenoid position closed center position exhaust center position pressure center position dual port valve: N.C./N.C. position dual port valve: N.O./N.O. C position dual port valve: N.C./N.O. position dual port valves are applicable to 000 and only. ilot type Internal pilot R xternal pilot xternal pilot specifications is not available for position dual port valves. Rated voltage 6 VC VC Light/Surge voltage suppressor R With light/surge voltage suppressor With surge voltage suppressor ack pressure check valve K uilt-in uilt-in back pressure check valve type is applicable to series only. ack pressure check valve is not available for position closed center and position pressure center. Refer to recautions on page

26 Manifold lectrical Wiring 0F/6F -sub Connector Type ( pins) Light/Surge voltage suppressor Light/Surge voltage suppressor Common Common SOL. Station SOL. Light/Surge voltage suppressor SOL. SOL. Station Light/Surge voltage suppressor SOL. Station SOL. This circuit has double wiring specifications for up to stations. Since the usable number of solenoids differs depending on the manifold type, refer to the table below. In the case of single solenoids, connect to SOL.. Furthermore, when wiring is specified on the manifold specification sheet, connections are made without skipping any connectors, and signals for single and, for double are in order, etc. Stations are counted from side (connector side) as the st. Since solenoid valves do not have polarity, either the +COM or COM can be used. sable No. of Solenoids Model Tie-rod base type 0 Cassette base type 6 to Max. no. of solenoids --6

27 -sub Connector imensions: 000 for -sub Connector Stations Tie-rod base manifold: SSV-0F (S, R, RS) - - C6, N7 C, N9 C0, N (-) When, port outlets are indicated on the side or side, the, ports on the opposite side are plugged. xternal pilot port positions and silencer discharge port positions are the same as, port outlet positions. With xternal ilot Specifications. (itch) = fitting [(), /() port] pplicable tubing O..: ø ø/" side IN rail holding screw (For IN rail mounting) (.) L L (Lateral connector entry) fitting [(), () port] pplicable tubing O..: ø6,ø/" ø, ø/6" ø0, ø/" (.). (L) 7.6 side quivalent to applicable -sub connector fitting [X: xternal pilot port] pplicable tubing O..: ø6 ø/" X { } JIS-X-0 MIL-C-0 fitting [: ilot XH port] pplicable tubing O..: ø6 ø/" X J ø. (For mounting) Light/Surge voltage suppressor Manual override ress and turn for the ( locking type. ) () port side: Orange () port side: Green L (Rail mounting hole pitch:.) L (Station n) (Station ) 0. -M NC [(), () with inch size ports] Connector case Release lever (oth sides) Silencer (ir discharge port) (uilt-in silencer specifications) With option 0.. / / 60.9 (For IN rail mounting) (6).7 6. (.9) 66. Individual S spacer.7 (0) MX Individual XH spacer Interface regulator -M- Interface regulator -00- L imension L n L L L L L n: Stations

28 Flat Ribbon Cable Connector J Tie-rod base Cassette base pplicable series Cassette base manifold / Tie-rod base manifold /// Number of connectors: 6, 0, 0 pins With strain relief Conforming to MIL-C-0 --7

29 For details about certified products conforming to international standards, visit us at Flat Ribbon Cable Connector Connector type G H Tie-rod base Cassette base Flat ribbon cable connector: 6 pins Flat ribbon cable connector: 0 pins Flat ribbon cable connector: 0 pins SSV 0 Valve stations 000 : Flat ribbon cable 6 pins stations 9 stations stations How to Order SSV 6 0 () ouble wiring specifications Specified layout () (p to solenoids possible.) Connector entry direction pward Lateral, port location S R RS 0 side ( to 0 stations) side ( to 0 stations) oth sides ( to 0 stations) ilot type H: Flat ribbon cable 0 pins stations stations stations ouble wiring () specifications Specified layout () (p to solenoids possible.) stations 0 G: Flat ribbon cable 0 pins 0 stations () ouble wiring specifications stations stations stations () Specified layout (p to solenoids possible.) stations Valve stations : Flat ribbon cable 6 pins H: Flat ribbon cable 0 pins 0 0 stations stations stations () ouble wiring specifications () Specified layout stations stations stations () ouble wiring specifications () Specified layout 0 (Ip to solenoids possible.) (p to solenoids possible.) 0 stations 0 stations G: Flat ribbon cable 0 pins 0 stations () ouble wiring 09 9 stations specifications 0 stations () Specified layout stations (p to solenoids possible.) Internal pilot Internal pilot/uilt-in silencer xternal pilot xternal pilot/uilt-in silencer 000 IN rail length specified Standard length For stations (Specify a longer rail than the 0 Note) For 0 stations standard length.) Note) ble to specify the length for stations up to stations for, which is available with stations at the maximum. : Flat ribbon cable 6 pins H: Flat ribbon cable 0 pins 0 stations () 0 stations () ouble wiring ouble wiring 0 stations stations specifications Specified layout () 0 0 stations stations specifications Specified layout () 0 (p to solenoids possible.) (p to solenoids possible.) 0 stations 0 stations G: Flat ribbon cable 0 pins 0 stations () ouble wiring 09 9 stations specifications 0 stations () Specified layout stations (p to solenoids possible.) Mounting irect mounting IN rail mounting (With IN rail) 0 IN rail mounting (Without IN rail) For When a longer stations IN rail is desired than the specified stations. (Specify For 0 0 a longer rail than stations the standard In case of 0, only IN rail fittings are attached Note ) ouble wiring specifications: Single, double and position solenoid valves can be used on all manifold stations. se of a single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note ) Specified layout: Indicate wiring specifications on a manifold specification sheet.

Air Cylinders Drive System Full Stroke Time and Speed at the End

Air Cylinders Drive System Full Stroke Time and Speed at the End ir Cylinders rive System Full Stroke Time and Speed at the nd 000 Solenoid Valve pplicable related components Silencer Tubing Speed controller S0F -0-0 pplicable bore size: ø0, ø6, ø0, ø00 Total stroke

More information

Gateway System Serial Transmission System

Gateway System Serial Transmission System Gateway System Series 00 I compliant V S000 C Tie-rod base Z pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000/000/000 Number of output points: points Connected to the 00GW

More information

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000 D-sub Connector J Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000//000 Number of connectors: pins MIL-C-08 Conforming to JIS-X-0 --6 For details

More information

5 Port Solenoid Valve Series SV

5 Port Solenoid Valve Series SV CT.S- -UK ort Solenoid Valve Series SV New Concept Type Manifold Series SV000/000/000/000 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations

More information

SV F. Series SV SV SZ SYJ. Series EX500 Decentralized Serial Wiring. How to Order Valve Manifold Assembly. How to Order Solenoid Valves

SV F. Series SV SV SZ SYJ. Series EX500 Decentralized Serial Wiring. How to Order Valve Manifold Assembly. How to Order Solenoid Valves side EX00 ecentralized Serial Wiring How to Order Valve Manifold Assembly Ordering example (000) Manifold S-WSAW-0B-C ( set) ouble solenoid 00-F ( sets) Single solenoid 00-F ( sets) side PW COM S-WSAW-0B-C

More information

Base Mounted Plug-in/Plug Lead: Single Unit

Base Mounted Plug-in/Plug Lead: Single Unit ase mounted VQ ase Mounted lug-in/lug Lead: Single Unit Model Number of solenoids Model Single Metal seal VQ Rubber seal VQ ouble Metal seal VQ Rubber seal VQ Closed Metal seal VQ VQ center Rubber seal

More information

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308 Cable ppendix Cable ppendix Multi-way cables The multi-pole connector cables used on SMC valves are common across several ranges. Cables are available in accordance with the MIL standard C-08 and also

More information

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),

More information

Terminal Block Box (Spring Type) SY3000/5000/7000 Series

Terminal Block Box (Spring Type) SY3000/5000/7000 Series INFORMATION 5 ort olenoid alve Terminal lock ox (pring Type) Y3000/5000/7000 eries Compact RoH Height 6.7 mm shorter (Approx. 9% reduction) Installation area of the terminal block box Reduced by approx.

More information

How to Order Manifold. Control unit Refer to pages to Kit/Electrical entry/cable length. kit (D-sub connector) U0 U1 U2

How to Order Manifold. Control unit Refer to pages to Kit/Electrical entry/cable length. kit (D-sub connector) U0 U1 U2 VQ000 ase Mounted Plug-in nit For details aout certified products conforming to international standards, visit us at www.smcworld.com. Type of connection VVQ VQ000 R port P port Port R Manifold Plug-in

More information

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000

More information

VQ1000. How to Order Manifold. Kit type

VQ1000. How to Order Manifold. Kit type - - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold

More information

Single Valve/Sub-plate Type IP67 Compliant 90-SV Series

Single Valve/Sub-plate Type IP67 Compliant 90-SV Series Single Valve/Sub-plate Type IP7 Compliant -SV Series SV 00 W U aterial restriction Series -SV000 -SV000 Thread type c F G N NPT T NPTF A B SOL.a SOL.a Type of actuation position single (EA) (P)(EB) position

More information

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring Type4 SY000/000 ase Mounted Monifold Stacking Type/DIN ail Mounted Individual Wiring How to Order Manifold SSY 4 0 U C6 How to Order Valve Manifold ssembly Ordering example SY000 SY000 Valve stations 02

More information

New Concept Connector Type Manifold

New Concept Connector Type Manifold New Concept Connector Type Manifold Series /000/3000/000 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration.

More information

Fieldbus System (Output device for driving 5 port solenoid valves)

Fieldbus System (Output device for driving 5 port solenoid valves) Fieldbus System (Output device for driving port solenoid valves) New Compact 8mm (ctual size) Space-saving Installation IP67 RoHS EtherNet/IP added! For units with D-sub connector, and when connected to

More information

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection Rubber Seal Port Solenoid Valve Series SJ000/000 Cassette Type Manifold 0 mm 7. mm (SJ000) 0 mm (SJ000) Non plug-in type Individual wiring manifold SJ000 SJ000 Can be mounted together. Connecter connection

More information

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal Port Solenoid Valve Cassette Type Manifold Rubber Seal 7.mm (SJ000) SJ000 SJ000 Can be mounted together. 0mm (SJ000) Connector connection New New cable type manifold is added! New Additional options are

More information

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector

More information

Plug Lead Unit: Flip Type

Plug Lead Unit: Flip Type Series ody orted lug Lead Unit: Flip Type For details about certified products conforming to international standards, visit us at www.smcworld.com. 0 Series Kit/Electrical entry/cable length F kit (D-sub

More information

Series PCW. PC Wiring System

Series PCW. PC Wiring System CT.ES0-0 PC Wiring System Series PCW The PC wiring system is a revolutionary new system that simplifies wiring between a PLC and all types of connected equipment. revolutionary new wiring system... 4VDC

More information

How to Order Manifold. Kit type L8 B4 B6 B8 LM

How to Order Manifold. Kit type L8 B4 B6 B8 LM 0 Stations station VVQ Series VQ000 The maximum and minimum number of are varied depending on. (Refer to the table below.) Series VQ000 ase Mounted Plug-in Unit Manifold Plug-in unit 08 C Cylinder port

More information

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A Type N SY/ ase ounted anifold Stacking Type/DIN Rail ounted Connector ox How to Order anifold SSY SY SY Specifications Symbol Specifications With connector box (CO spec.) N With connector box ( CO spec.)

More information

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M. V3 Cover

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 0 PW COM Rubber Seal Port Solenoid Valve Series SZ000 Cassette Type Manifold The plug-in cassette system makes valve replacement easy. plug-in manifold has been created with a height of. mm (including

More information

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1 Port Solenoid Valve Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Non plug-in manifold 0 0 S 60 Stations stations 0 stations SUP/EXH

More information

Series SY3000/5000 How to Order Manifold

Series SY3000/5000 How to Order Manifold Type N ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN Rail Mounted/Connector ox SY/ How to Order Manifold SSY SY SY Specifications Symbol Specifications With connector box (COM spec.) N With

More information

Example. U side. Stations SY5000

Example. U side. Stations SY5000 45 Type 5 ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN ail Mounted/Individual Wiring Series SY3000/5000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 3 45 05 U C6 Example

More information

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve CT.E- ase Mounted Type Series VQ Port Metal Seal/Rubber Seal Solenoid Valve dvanced manifold va the new age of factory au ase Mounted Type Space saving profile Clean space saving design with all pilot

More information

Fieldbus System (Gateway Decentralized Type)

Fieldbus System (Gateway Decentralized Type) Fieldbus System (Gateway Decentralized Type) * * Except the SY, VQC and S0700 valves GW Unit which supports PROFINET added. New M connector type Input Unit added. Decentralized valve installation Valves

More information

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer Base Mounted Metal Seal/Rubber Seal VQ Built-in silencer, direct exhaust Space-saving profile All pilot valves are compactly mounted on one side. The space-saving design of mounting all fittings on one

More information

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating / ort Solenoid Valve ubber Seal Series SYJ000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Specifications JIS Symbol port port (manifold) position

More information

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve ubber Seal / ort Solenoid Valve Series 000 / 000 / 000 [Option] SJ SY SV SZ V S000 VQ VQ VQ VQC VQZ SQ VFS VF VQ Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Series VQ Rubber Seal Space-saving profile Clean space saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type20P 5 Port Solenoid Valve ody Ported Manifold ar Stock Type/Flat Ribbon Cable Series SY3000/5000/7000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 5 20P 05 Manifold series 3 SY3000

More information

How to Order Manifold. Option Symbol

How to Order Manifold. Option Symbol Series Plug Lead nit For details about certified products conforming to international standards, visit us at www.smcworld.com. Series/Manifold 12 Stations 01 1 station Kit/Electrical entry/cable length

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Rubber Seal Series VQ Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve CT.ES8 / ort Solenoid Valve Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M.7 to M2. 앬 Flow Characteristics Series Cover (stainless

More information

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I ISO Standard Solenoid Valve Series VQ7-6/7-8 (Size ) (Size ) Conforms to ISO Standard /I.0- Ideal for driving cylinders up to Large flow capacity ø00 (VQ7-6, Size ) ø60 (VQ7-8, Size ) Nl/min VQ7-6: 668.

More information

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot ubber seal ort ilot Solenoid Valve Series SYJ00 Specifications efer to www.smcworld.com for details of products compatible with overseas standards. Body ported Base mounted Fluid Operating pressure range

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Port Solenoid Valve Metal Seal Rubber Seal Series Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type1P Type2P 5 Port Solenoid Valve ase Mounted Manifold ar Stock Type/Flat Ribbon Cable Series /5000/000 How to Order Manifold Type 1P/Compact style SS5Y 5 1P 05 C8 Manifold series 3 5, port size Thread

More information

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit CT.EUS8 UK ower Consumption / ort Solenoid Valve With ower Saving Circuit Series SYJ000/000/7000 Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced

More information

Series VQZ1000/2000/3000 Single Unit

Series VQZ1000/2000/3000 Single Unit +- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and

More information

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications Series -SQ00 Port Solenoid Valve Plug-in Unit [Option] How to Order Manifold Electrical entry F kit D-sub connector kit P kit SSQ 08 FD Kit type Flat ribbon cable connector kit J kit Flat ribbon cable

More information

Gateway Type Serial Transmission System

Gateway Type Serial Transmission System P99-EX-B Gateway Type Serial Transmission System P Maximum 8 point control (64 inputs/64 outputs) P Flexibility of manifold valve installation improved with 4 branch wiring Flexible installation and removal

More information

Series SYJ300/500/700

Series SYJ300/500/700 ort Solenoid Valve ubber Seal Series SYJ00/00/00 Low power consumption: 0.W (Without light) (Current draw: 1m at 4V DC) Completely interchangeable ilot exhaust with the previous series VJ00/00/00 and VZ00/00.

More information

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

CAT.E152-5 Port Solenoid Valve/Body Ported Cassette Type Manifold. Series SZ3000

CAT.E152-5 Port Solenoid Valve/Body Ported Cassette Type Manifold. Series SZ3000 CAT.E- Port Solenoid Valve/Body Ported Cassette Type Manifold Series SZ000 The plug-in cassette system makes valve replacement easy. A plug-in manifold has been realized having a manifold height of.mm

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

5 Port Solenoid Valve Plug Lead Type

5 Port Solenoid Valve Plug Lead Type 5 Port Solenoid alve Plug Lead Type Series Body Ported Flow rate characteristics For single/double solenoid C [dm 3 /(s bar)]: 0.6 Single Unit alve width: 7.4 mm Possible to drive cylinders: Up to ø32

More information

3, 5 port pilot operated valve Pneumatic valve / master valve. Discrete valve. Manifold

3, 5 port pilot operated valve Pneumatic valve / master valve. Discrete valve. Manifold K/K, pilot operated valve neumatic valve / master valve MNE0 MNE0 M MN W WG MNS0 MNS0 T L-/ S/0 S/ K/ F CONTENTS Safety precautions 776 Discrete valve ody ing (K/K to ) 868 Sub-plate ing (K to ) 87 Manifold

More information

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle. Multistage Ejector 112/212 Series Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus

More information

3 Port Solenoid Valve

3 Port Solenoid Valve 3 ort Solenoid Valve Series VKF300 ubber Seal Direct Operated oppet Type Compact yet provides a large flow capacity Body width 8 mm vailable in vacuum applications ( 0. ka) Can be used in vacuum/release

More information

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles ort Solenoid Valve: ase Mounted Metal Seal/Rubber Seal Series Space and capacity saving ilot valve is gathered at one side. Space saving design which does not have any protrusions. Space saving Capacity

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

Applicable bore size. CC-Link. EtherNet/IP. Decentralized Serial Wiring. EtherCAT I/O. Serial unit: EX600 IP67 compliant. Serial unit: EX500

Applicable bore size. CC-Link. EtherNet/IP. Decentralized Serial Wiring. EtherCAT I/O. Serial unit: EX600 IP67 compliant. Serial unit: EX500 5 Port Solenoid Valve Series C000 Metal Seal Rubber Seal Compact and large flow Type (Series) Manifold pitch (mm) C000 5 6. 0.7.7 7. 0..0 to ø Note) Flow characteristics: position single, / 5/ (/ R/R)

More information

Coolant Valve. Air Operated/External Pilot Solenoid

Coolant Valve. Air Operated/External Pilot Solenoid Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) lange type (3 to ) Low water hammer or details, refer to page

More information

Series SYJ3000/5000/7000

Series SYJ3000/5000/7000 , ort Solenoid Valve ubber Seal Series SYJ000/000/7000 Low power consumption: 0.W(Without light) (Current draw: 1m at V DC) right color tone and state of the art design SY SYJ SX VK VZ VF VF V7 V Completely

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

MRK 25 M a r k 2 5 d i r e c t s o l e n o i d a c t u a t e d v a l v e s T C H N C L T V L V M

MRK 25 M a r k 2 5 d i r e c t s o l e n o i d a c t u a t e d v a l v e s T C H N C L T V L V M MRK 25 SRS direct solenoid actuated valves MRK 25 MRK 25 M a r k 2 5 d i r e c t s o l e n o i d a c t u a t e d v a l v e s T C H N C L T................................................... 3 V L V M O

More information

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) type (3 to ) Low water hammer or details, refer to page 07. Large

More information

Space Saving Vacuum Ejector / Vacuum Pump System

Space Saving Vacuum Ejector / Vacuum Pump System CT.US0-1'-UK Space Saving acuum jector / acuum ump System Conventional ZX 21. mm mm ZQ Series ZQ Width mm Weight 9 g Single unit with vacuum pressure switch and suction filter jector ump System NW asy-to-use

More information

F Kit. D-sub. connector. D-sub. connector) Compatible network DeviceNet PROFIBUS DP. CC-Link. Compatible D-sub connector. Output

F Kit. D-sub. connector. D-sub. connector) Compatible network DeviceNet PROFIBUS DP. CC-Link. Compatible D-sub connector. Output Series VQC000 ase Mounted: Variations 5 Port Solenoid Valve Series VQC000 Sonic Conductance C[dm /(s bar)] Values: CYL EXH / 5/ Single/Double position (Closed center) pplicable bore size Compatible network

More information

3 Port Air Operated Valve. SYJA300 Series. How to Order. Nil Without sub-plate. Type of actuation. Normally closed Normally open

3 Port Air Operated Valve. SYJA300 Series. How to Order. Nil Without sub-plate. Type of actuation. Normally closed Normally open 3 ort ir Operated Valve SYJ300 Series How to Order SYJ3 M3 Bracket Nil Without bracket F With bracket *The bracket is not mounted. *The bracket cannot be retrofitted later. SYJ3 Type of actuation Normally

More information

0.35 W (Without light)

0.35 W (Without light) Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:

More information

2.26 S OLENOID VALVES S ERIES VQ1000

2.26 S OLENOID VALVES S ERIES VQ1000 2.26 S OLENOID VALVES 5 PORT M ETAL S EAL/RUBBER S EAL U LTRA H IGH S PEED S OLENOID VALVE High Speed Response from new Solenoid Design. Long Life: Over 200 Million Cycles can be with Patent Pilot Valve

More information

Series SV1000/2000/3000/4000

Series SV1000/2000/3000/4000 Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double

More information

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid alve Plug Lead Type RoHS New Body Ported Flow-rate characteristics For single/double solenoid C [dm 3 /(s bar)]: 0.6 Single Unit alve width: 7. mm Possible to drive cylinders: Up to ø32

More information

501 SERIES. 501 Series Directional Control Valve Platform. Featuring Higher Flow in a Compact Valve Package. Commissioning Capabilities

501 SERIES. 501 Series Directional Control Valve Platform. Featuring Higher Flow in a Compact Valve Package. Commissioning Capabilities 501 Series irectional ontrol Valve Platform Featuring Higher Flow in a ompact Valve Package ommissioning apabilities Solenoid air pilot actuated Low wattage.8 wall for application solenoids Polarity insensitive

More information

ADEX Series Air Control Valves A00.01 Cv M3 Port A05.18 Cv M5 Port A12.47 Cv 1/8" Port zpv02 A B C D E F G H. Section H

ADEX Series Air Control Valves A00.01 Cv M3 Port A05.18 Cv M5 Port A12.47 Cv 1/8 Port zpv02 A B C D E F G H. Section H X Series ir ontrol alves 00.0 v ort 05.8 v 5 ort.47 v /8" ort zpv02 Section www.parker.com/pneu/adex asic alve unctions... 2 asic alve eatures... ommon art umbers / R Type alves... 4 odel umber Index /

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Series 000 Compact and lightweight: 3 mm width Compact yet provides

More information

1 1/4 (32A) to 2 (50A) added.

1 1/4 (32A) to 2 (50A) added. Coolant Valve 0.5 MPa.0 MPa.6 MPa RoHS /4 (3) to (50) added. Flow rate Cv (For 0.5 MPa specification) 3 4 5 0 0 30 Cv (kv) 40 5 million cycles or more Port size 70 6.5 (5.6) 3/8 (0), / (5).8 (0.) 3/4 (0)

More information

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa oolant Valve Series S External pilot solenoid S ir operated S How to Order 0 0 Y 0 0 T Z q w e r t y u i o!0!!!!! q Series S00 S00 S00 w Valve type ormally closed ormally open e Seal material R FKM r Pressure

More information

4/5 Port Air Operated Valve. SYJA3000 Series. How to Order. (Manifold use only) Type of actuation. 2 position single. 3 position closed center

4/5 Port Air Operated Valve. SYJA3000 Series. How to Order. (Manifold use only) Type of actuation. 2 position single. 3 position closed center 4/ ort ir Operated Valve SYJ000 Series How to Order ody ported SYJ M racket Nil Without bracket F With bracket *Refer to page 47 for the details of the brackets. ase mounted (4 port) SYJ 2 0 (Manifold

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

4-Way, 5-Port, 2 & 3-Position Solenoid and Remote Pilot 1/2" & 3/4" Ports. Technical & Service Data. Pneumatic

4-Way, 5-Port, 2 & 3-Position Solenoid and Remote Pilot 1/2 & 3/4 Ports. Technical & Service Data. Pneumatic atalog VL-UTO-/US (Revised 6/0/0) pplication & Model Selection S utomotive Subbase Valves -Way, -ort, & -osition Solenoid and Remote ilot /" & /" orts pplication ual pressure or diverter valve operation

More information

ADEX Series. Air Control Valves. Section D

ADEX Series. Air Control Valves. Section D X Series ir ontrol alves 00.0 v.8 v.47 v ort 5 ort /8" ort Section www.parker.com/pneu/adex X iking Z asic alve unctions...00 asic alve eatures...0 ommon art umbers / R Type alves...02 odel umber Index

More information

Isys Micro Series. Valve Products. Operating information. Material specifications. Pilot configuration

Isys Micro Series. Valve Products. Operating information. Material specifications. Pilot configuration atalog 000-3US The Valve System incorporates a space saving back to back valve mounting design, and achieves flow rates of 0.35 v per valve with valves having a combined width of mm. This plug-in valve

More information

Base Mounted Plug-in Unit

Base Mounted Plug-in Unit For details about certified products conforming to international standards, visit us at www.smcworld.com. Plug-in Unit SI unit COM N VVQC VVQC C C C6 M CM 6 B B B6 B M Series VQC Manifold model Plug-in

More information

Vacuum Release Valve with Restrictor

Vacuum Release Valve with Restrictor INFORMATION Series SY3/5 Plug-in Only for External Pilot Vacuum Release Valve with Vacuum suction and release can be controlled with a single valve! PE Pilot EH port Flow rate adjustment of release air

More information

385 & 962 Series The lectroaire valve is a compact, air operated, electrically lectroaire valves can be remotely mounted for control of double acting

385 & 962 Series The lectroaire valve is a compact, air operated, electrically lectroaire valves can be remotely mounted for control of double acting Model Number Index Housing Series Type ort Variation Voltage 962 2 001 40 Series Solenoid Operated Housing Type 962 Valve less racket 972* Valve less racket 902 Valve less racket 385 Valve with racket

More information

Space Saving Vacuum Ejector/Vacuum Pump System

Space Saving Vacuum Ejector/Vacuum Pump System Space Saving acuum Ejector/acuum ump System Series Current 21.6 mm mm Width mm [Option] Weight 9 g Single unit with vacuum pressure switch and suction filter ZK2 ZR Z Z ZM ZL -X267 ZU Ejector.2 ump System.118

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000) 5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry

More information

Exclusively for air pressure system and air-hydro circuit control

Exclusively for air pressure system and air-hydro circuit control Process Valve Series Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external

More information

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A) ort Solenoid Valve ubber Seal Series SY00 Low power consumption: 0.W (Standard, Without light) (Current draw: m at V DC) Large flow capacity style:0.7w (Current draw: m at V DC) Body width: 0mm 7.8 Nl/min

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

CMF2 Series Applicable cylinder bore size: Max. ø160

CMF2 Series Applicable cylinder bore size: Max. ø160 4G/ M4G/ Individual wiring manifold ISO size 2 DIN terminal ox type 5 port pilot operated valve ISO conformed valve 2 Series pplicale cylinder ore size: Max. ø160 MN4G/ Common specifications 4G/ W4G/2

More information