ISO Interface Solenoid Valve/SIZEq Metal Seal. Standard Specifications. Fluid Operating pressure. Ambient and fluid temperature

Size: px
Start display at page:

Download "ISO Interface Solenoid Valve/SIZEq Metal Seal. Standard Specifications. Fluid Operating pressure. Ambient and fluid temperature"

Transcription

1 ISO Interface Solenoid Valve/SIZEq Metal Seal SeriesVS7-6 VS7-6-FPG-D VS7-6-FG-D Accessories Mounting bolt (with washer) Packing Indicator Iight Optional Specifications VS7-6-FG-S Note: Please note that single subplates and manifolds have changed colour from platinium silver to white as standard. Valves will remain platinium silver. TA-B-5 X 35 AXT (Option) VS7-6-FHG-D Surge voltage Available suppressor Reverse R1/R port: Pressure in pressure R1=P1 pressure R=P pressure, P1=P < position 3 position Option Single solenoid (FG-S) Double solenoid (FG-D) Reverse pressure (YZ-S) Reverse pressure (YZ-D) Closed centre (FHG-D) Exhaust centre (FJG-D) Double pilot check (FPG-D) Pressure centre (FLG-D) Standard Specifications Fluid Operating pressure Ambient and fluid temperature Manual override Electrical entry Lubrication Part No. Rated voltage (V) Inrush current (A) Holding current (A) Allowable voltage (V) Insulation Interface regulator model (1) Applicable solenoid valve Regulation port Proof pressure Max. operating pressure Set pressure range Ambient and fluid temperature Pressure gauge port size Weight (kg) Air supply side eff. area S (P=0.7MPa, P1=0.5MPa) () (mm ) Air exhaust side eff. area S (P=0.5MPa) () No. of positions (Single) (Double) 3 (Closed centre) 3 (Exhaust centre) 3 (Pilot check) A A A A AXT511 B-1 (V) AXT511 B- (V) AXT511 B-3 (V) AXT511 B-4 (V) 0V AC 50/60 Hz 00V AC 50/60 Hz 4V DC 1V DC 0.049/ / / / to 1% of rated voltage Class B (130 o C) or equivalent A: With -M4 X 46 bolts for position valve, B: With -M4 X 54 bolts for 3 position valve Note) Based on JIS C4003. (V): Pilot EXH individual style. Model VS7-6-FG-S- -Q VS7-6-FG-D- -Q VS7-6-FHG-D- -Q VS7-6-FJG-D- -Q VS7-6-FPG-D- -Q Effective area (With 1 4 sub-plate) (mm ) (Nl/min) 7 (147.5) 7 (147.5) 5.5 (1374.) 7 (1374.) 0 (79.65) (1) Min. operating frequency is based on JIS B8375. (Once every 30 days) () Based on JIS B (At 0.5MPa) Air/lnert gas 0.1 to 1.0MPa 5 to 60 o C Non-locking style, Locking style DIN connector Non-lube If provided, use turbine oil (ISO, VG3) 150/50 m/s Shock resistance (Vibration resistance) (1) Applicable sub-plate VS7-1 (ISO size q) Option Note) Shock resistance: No malfunction resulted from the impact test using a drop impact tester. The test was performed on the axis and right angle directions of the main valve and armature, for both energized and de-energized states. (Value in the initial stage.) Vibration resistance: No malfunction occurred in a one-sweep test between 8.3 and 000 Hz. Test was performed at both energized and de-energized states to the axis and right angle directions of the main valve and armature. (Value in the initial stage.) Pilot Valve/Spacifications Option/Interface regulator Model P/A P/B A/EA B/EB ARB50 VS7-6 A B P 1.5MPa 1.0MPa 0.1 to 0.83 Mpa 5 to 60 o C Max. operating rate (1) (cycle/sec.) mm 18 mm Note 1) Use "ABR" for pressure centre style and reverse pressure style. Note ) Synthesized effective area with position single style solenoid valve Response time () (sec) 0.05 or less or less or less or less 0.05 or less Weight (3) (kg) (3) Weight without sub-plate (Sub-plate: 0.37kg) (4) (1) and () are the rates in the condition of controlled clean air SV SY SYJ SX VK VZ VF VFR VP7 VQC SQ VQ VQ4 VQ5 VQZ VQD VFS VS VS7 VQ7

2 VS7-6 Double Pilot Check Spacer/Series FPG Cylinder mid-stroke, long term retention possible. The use of the double pilot check spacer equipped with a built-in double check valve enables the cylinder to stop and remain at mid-stroke for long periods regardless of air leakage between the spool and sleeve. 3 Position Double Pilot Check Valve (Wedge packing style) VS7-6-FHG-D- R 3 position double pilot check valve achieves a reduction in air leakage as a result of main valve construction which features co-axial wedge packing (Max. leakage: cm 3 /min (ANR)). Double Pilot Check Spacer Specifications Double pilot check spacer model Applicable solenoid valve/air operated valve Leakage (cm 3 /min (ANR)) With one side solenoid energized. (With one side pilot air pressured) Both sides solenoids de-energized. (With both sides pilots not air pressured) Check Valve/Operation Pressure Characteristics The check valve will operate correctly providing that cylinder side pressure is not in excess of two times the supply pressure. P P B A VV71-FPG Series VS7-6/VSA7-6 R1 R R1 R R1 R Cylinder Speed/Stop Position Range 0 Caution Verify that there is no leakage from the pipes between valve and cylinder, and from fittings. Check for leaks by using neutral detergent solution before use. Also check the cylinder packing and the piston packing. If there is leakage, cylinder may not stop at the mid-stroke position, and could move immediately after the valve is de-energized. Be aware that if the exhaust side is restricted excessively, the intermediate stopping accuracy will decrease and will lead to improper intermediate stops. Cylinder Operation Chart Cylinder ø st ø st Supply Load factor pressure Load ø50 ø80 0.MPa 5kg 51% 8%

3 VS7-6 How to Order E VS7 6 FG S 1 Q Symbol Number of solenoid Rated voltage Option Port size of sub-plate Connector S Single None Without sub-plate Connector FJG D Double N Indicator light A0 Side piping W/o connector FG YZ FHG Option Ordering source area code Code areas Japan, Asia - Australia E Europe N North America FPG FIG Caution DIN Connector (Wiring) Order Made Precautions Specifications Interface regulator model Applicable solenoid valve Regulation port Max. operating pressure Setting pressure range Ambient and fluid temperature Pressure gauge port size Weight (kg) Air supply side eff area (mm ) S (P=0.7MPa, P1=0.5MPa) Air exhaust side eff area S (P=0.5MPa) 9 0V AC 00V AC 4V DC 1V DC Others (50V or less) Contact SMC for other voltages (9) Protective class class I (Mark: ) M Direct manual override A03 Side piping 3 8 Indicator light with surge Z voltage suppressor B0 Bottom piping 1 4 Wedge packing style with MR direct manual override B03 Bottom piping 3 8 R Wedge packing style R port: 3 8 V Individual pilot EXH If specifying more than one symbol, indicate them in the alphabetical order. Interface Regulator Specifications Thread Rc (PT) F G (PF) N NPT T NPTF Be sure to read before handling. Refer to p.0-33 to 0-36 for Safety Instructions and common precautions. P P A B Note: Manifold exploded view see page for details. A B EA EB ARB50 VS7-6 A B P 1.0MPa (1) 0.1 to 0.83MPa (1) 5 to 60 o C (3) mm 18 mm Note 1) Maximum operating pressure of solenoid valve is 0.9 MPa. Note ) Be sure to set pressure within setting pressure range of the solenoid valve. Note 3) Solenoid valve: Max. 50 o C Note 4) Synthesized effective area with position single style solenoid valve. Note 5) Supply pressure to interface regulator only from P port except when it is used with reverse pressure style valve. Use the ARB or ARB3 model to combine a pressure centre valve and the A and B port pressure reduction of a spacer style regulator. Use the ARB or ARB3 model to combine a reverse pressure valve and a spacer style regulator. The P port pressure reduction cannot be used. To use a perfect valve and a spacer style regulator, use a manifold or a sub plate as the standard and stack in the following order: the perfect spacer, spacer style regulator, and the valve. When a closed centre valve is combined with the A and B port pressure reduction of a spacer style regulator, it cannot be used for intermediate stops of the cylinder because of the leakage from the relief port of the regulator SV SY SYJ SX VK VZ VF VFR VP7 VQC SQ VQ VQ4 VQ5 VQZ VQD VFS VS VS7 VQ7 Power Source and Wiring qmake sure all contacts are secure. wvoltage should be held within the allowable voltage range. How to calculate flow rate Refer to p.0-36 for flow rate calculations

4 VS7-6 Construction VS7-6-FG-S- -Q VS7-6-FG-D- -Q VS7-6-FHG- -Q VS7-6-FJG- -Q VS7-6-FPG- -Q VS7-6-FHG-D- R-Q Replacement Parts No. Description Part No. Material VS7-6-FG-S VS7-6-FG-D VS7-6-FHG VS7-6-FJG VS7-6-FPG q w e r t SUS NBR NBR NBR NBR AXT AXT AXT AXT MY-11N AXT AXT AXT MY-11N VFS AXT AXT AXT MY-11N VFS AXT AXT AXT MY-11N VFS AXT AXT AXT MY-11N Return spring Gasket Gasket Gasket Mini-Y-packing Pilot valve assembly Detent assembly y u i o Packing Double pilot check spacer NBR AXT511A- AXT511A- AXT511B- AXT500-9 AXT AXT511B- AXT511B- VV71-FPG

5 VS7-6 Without Sub-plate/Dimensions VS7-6-FG-S- -Q VS7-6-FG-D- -Q SV SY SYJ SX VK VZ VF VFR VP7 ( ): In case of direct manual override style. VS7-6-FHG- -Q VS7-6-FJG- -Q VS7-6-FPG- -Q VQC SQ VQ VQ4 VQ5 VQZ VQD VFS VS VS7 VQ7 ( ): In case of direct manual override style

6 VS7-6 With Sub-plate/Dimensions VS7-6-FG-S- Port size of sub-plate -Q VS7-6-FG-D- Port size of sub-plate -Q VS7-6-FHG- Port size of sub-plate -Q VS7-6-FJG- Port size of sub-plate -Q VS7-6-FPG- Port size of sub-plate -Q ( ): In case of direct manual override style

7 VS7-6 Interface Speed Control Interface Speed Control AXT503-3A Symbol Interface Regulator Interface Regulator/Dimensions P regulation/arb50-00-p SV SY SYJ SX VK VZ VF VFR VP7 Symbol P port regulation A port regulation A port regulation/arb50-00-a B port regulation/arb50-00-b VQC SQ VQ VQ4 VQ5 VQZ VQD VFS VS VS7 VQ7 B port regulation

8 Series VS7-6 Sub-plate Sub-plate: Series VS7-1/VSA7-1 Specifications Applicable solenoid valve/air operated valve Sub-plate size Piping Weight All R ports: 3 8 Series ISO size q ISO size q Side piping Bottom piping kg How to Order E VS7 1 A0 A0 A03 B0 B03 Piping Side piping 1 4 Side piping 3 8 Bottom piping 1 4 Bottom piping 3 8 R port: 3 8 Thread Rc (PT) F G (PF) N NPT T NPTF Ordering source area code Code areas Japan, Asia - Australia E Europe N North America

9 Series VS7-6 Manifold Manifold: Series VV71 Note: Please note that single subplates and manifolds have changed colour from platinium silver to white as standard. Valves will remain platinium silver. Standard Specifications Manifold block size Applicable solenoid valve Number of stations A, B-port Piping P, R1, R-port F. R. Unit Individual SUP spacer Individual EXH spacer Gallery blank disc (Differential pressure style) Including F.R.Unit ( equivalent to stations ) The manifold Series VV71 has a wide variety of functions and piping, compatible with virtually any application. Common EXH Style Every valve is supplied and exhausted by the same SUP and EXH ports running through the connected manifolds. This is the most popular configuration. When there are 5 or more stations operating simultaneously and pilot back pressure is 0.kgf/cm or more, it is recommended that all pilot EXH ports (PE) of the manifold base (4 on U side and on D side, total 6 ports) be open. Also, use "AN1-01" for silencer for pilot EXH. Multiple Pressure SUP Style Allows supply of or more different pressure to one manifold. Put in a gallery blank disc ( AXT50-14 ) between the stations to operate at different pressures. A dual pressure supply can be supplied from both the left and right sides of the manifold. If 3 or more pressures are supplied, the individual SUP spacer should be used. Bottom Piping Style/1/4, 3/8 ( A, B-port ) When side piping appearance is not acceptable or space is limited, either some of, or all ports, can be arranged with bottom piping. Individual Pilot EXH Style If there are many valve stations operating at the same time or operation frequency is high, trouble caused by back pressure will be prevented by using individual pilot EXH style valve ("VS "). ISO size q Series ISO size q 1 to One-touch fitting: ø6, ø8, ø One-touch fitting: ø1 Air filter (Auto drain, Manual drain), Regulator, Pressure switch, Air release valve VV71-P- (0: 1 4,03: 3 8,C: ø) VV71-R- (0: 1 4,03: 3 8,C1: ø1) AXT50-14 Individual EXH Style Every valve has an independent EXH port of its own. An Individual EXH spacer (VV71-R- ) mounted on the manifold block allows each valve to exhaust individually. Individual SUP Style An Individual SUP spacer (VV71-P- ) mounted on the manifold block allows each valve to be supplied individually. Main EXH Back Pressure Block Style If there are many valve stations operating at the same time and main EXH back pressure may cause trouble, mount back pressure block plate ("AXT503-37A") to prevent effects of main EXH back pressure. SV SY SYJ SX VK VZ VF VFR VP7 VQC SQ VQ VQ4 VQ5 VQZ VQD VFS VS VS7 VQ

10 VS7-6 How to Order (Manifold) E VV R 03D Q Stations Piping/A, B port Control unit Piping/P, R1, R Port 1 1 0R 1 4 (Right) Without 0D 1 4 (Bottom) 03R 3 8 (Right) Filter with auto-drain, regulator, 0U 1 4 (Top) A 0L 1 4 (Left) air release valve 0B 1 4 (Both sides) Includes F. R. Unit 03L 3 8 (Left) Filter with auto-drain, regulator, 03D 3 8 (Bottom) AP (equivalent to 0Y 1 4 (Bottom) pressure switch, air release valve 03U 3 8 (Top) stations). 03Y 3 8 (Bottom) M Filter with manual drain, regulator, air release valve 03B 3 8 (Both sides) C6R One-touch for ø6 tube (Right) Filter with manual drain, regulator, One-touch fitting for MP C1D C8R One-touch for ø8 tube (Right) pressure switch, air release valve ø1 tube (Bottom) CR One-touch for ø tube (Right) Filter with auto-drain, regulator One-touch fitting for F C1U C6L One-touch for ø6 tube (Left) (air release valve-blank) ø1 tube (Top) C8L One-touch for ø8 tube (Left) Filter with manual drain, regulator One-touch fitting for G C1B CL One-touch for ø tube (Left) (air release valve-blank) ø1 tube (Both sides) Combination C Air release valve (filter, regulator-blank) Combination Please provide E Air release valve Please provide piping piping specifications. specifications. Ordering source area code Code areas - Japan, Asia Australia E Europe N North America Silencer box SB W/o silencer box Silencer box Mounting position of silencer box is in accordance with piping of R1 and R ports. Air release valve/rated voltage Order Made Without air release valve 0V AC 50/60Hz 00V AC 50/60Hz 4V DC 1V DC Others(50V or less) Contact SMC for other voltages (9) Protective class class I (Mark: ) Note) Manifold exploded view see page for details F. R. Unit for Manifold Air filter, regulator, pressure switch, air release valve can be directly mounted to the manifold base, simplifying piping. Classification of Control Unit Symbol Control unit Air filter with auto-drain Air filter with manual drain Regulator Air release valve Pressure switch Blank plate (Air release valve) Blank plate (Air filter, Regulator) A AP M MP F G C E Options Blank plate Air release valve adaptor plate F. R. Unit Pressure switch Manifold/Applications AXT50-9A (for manifold) AXT50-18A (for air release valve adaptor plate) MP (for control unit/filter regulation valve) MP3 (for pressure switch) AXT50-17A VAW-A (Adaptor plate, filter with auto drain cock, regulator) VAW-M (Adaptor plate, filter with manual drain cock, regulator) IS30-X30 (-M5 X 1) Interface for reverse pressure R1, R individual EXH spacer Interface speed control Lock up cylinder adaptor plate Interface Relieving regulator style Main EXH back pressure block plate Silencer for pilot EXH Residual pressure release valve spacer Individual SUP spacer with residual pressure release valve Double pilot check spacer with residual pressure release valve AXT50-1A-1 ( 3 8 ) VV71-R-03 AXT503-3A AXT50-6A P port regulation ARB A port regulation B port regulation AXT503-37A AN1-01 VV71-R-AB 0: 1 4 VV71-PR- 03: 3 8 VV71-FPGR Manifold blocks necessary for mounting 1 F. R. Unit/Specifications Air filter (w/auto-drain, w/manual drain) Filtration 5µm Regulator Set press. (secondary) 0.05 to 0.85MPa Pressure switch Pressure regulation range 0.1 to 0.7MPa Contacts 1ab Rated current (Induction load) 15V AC 3A, 50V AC A Air release valve (Single only) Operating press. range 0.1 to 1.0MPa 1.19-

11 VS7-6 Manifold/Dimensions Common EXH SV SY SYJ SX VK VZ VF VFR ( ): In case of direct manual override style. Individual EXH L: Dimensions L n 1 L1 L Manifold weight general formula=0.43n+0.49 (kg) n: Station Equation L1=43n+64 L=43n+76 VP7 VQC SQ VQ VQ4 VQ5 VQZ VQD VFS VS VS7 VQ7 ( ): In case of direct manual override style

12 VS7-6 Manifold/Dimensions F. R. Unit ( ): In case of direct manual override style. Interface Speed Control L: Dimensions n: Station L n Equation L1 L L1=43n+64 L=43n+76 L L3=43n+11 Interface Regulator Bottom Piping

13 ISO Interface Solenoid Valve/SIZEw Metal Seal SeriesVS7-8 VS7-8-FPG-D VS7-8-FG-D Accessories Mounting bolt ( with washer ) Packing Indicator Iight Optional Specifications Surge voltage suppressor Reverse pressure TA-B-6 X 45 AXT5-13 ( Option ) Available VS7-8-FHG-D VS7-8-FG-S Note: Please note that single subplates and manifolds have changed colour from platinium silver to white as standard. Valves will remain platinium silver. R1/R port: Pressure in R1=P1 pressure R=P pressure, P1=P < position 3 position Option Single solenoid ( FG-S ) Double solenoid ( FG-D ) Reverse pressure (YZ-S) Reverse pressure (YZ-D) Closed centre ( FHG-D ) Exhaust centre ( FJG-D ) Double pilot check ( FPG-D ) Pressure centre ( FIG-D ) Standard Specifications Fluid Operating pressure Ambient and fluid temperature Manual override Electrical entry Lubrication Part No. AXT511C-1 (V) AXT511C- (V) AXT511C-3 (V) AXT511C-4 (V) Rated voltage (V) 0V AC 50/60 Hz 00V AC 50/60 Hz 4V DC 1V DC Inrush current (A) 0.049/ /0.01 Holding current (A) 0.031/ / Allowable voltage (V) 85 to 1% of rated voltage Insulation Class B (130 o C) or equivalent (V): Pilot EXH individual style. Blank plate No. of positions (Single) (Double) 3 (Closed centre) 3 (Exhaust centre) 3 (Pilot check) Interface regulator model (1) Applicable solenoid valve Regulation port Proof pressure Max. operating pressure Set pressure range Ambient and fluid temperature Pressure gauge port size Weight (kg) Air supply side eff. area S (P=0.7MPa, P1=0.5MPa) () (mm ) Air exhaust side eff. area S ( P=0.5MPa) () Model VS7-8-FG-S- -Q VS7-8-FG-D- -Q VS7-8-FHG-D- -Q VS7-8-FJG-D- -Q VS7-8-FPG-D- -Q ARB350 VS7-8 A B P 1.5MPa 1.0MPa 0.1 to 0.83 MPa 5 to 60 o C P/A P/B A/EA B/EB mm 53 mm 7 7 Note 1) Use "ABR" for pressure centre style and reverse pressure style. Note ) Synthesized effective area with position single style solenoid valve. AXT51-9A Effective area (WitH 3 8 sub-plate) (mm ) (Nl/min) 58 ( ) 58 ( ) 58 ( ) 58 ( ) 40 (159.30) (1) Min. operating frequency is based on JIS B8375. (Once in 30 days) () Based on JIS B (At 0.5MPa) Air/lnert gas 0.1 to 1.0MPa 5 to 60 o C Non-locking style, Locking style DIN connector Non-lube If provided, use turbine oil ( ISO, VG3 ) 150/50 m/s Shock/Vibration resistance (1) Applicable sub-plate VS7- (ISO size w ) Option NOTE 1): Shock resistance: No malfunction resulted from the impact test using a drop impact tester. The test was performed on the axis and right angle directions of the main valve and armature, for both energized and de-energized states. (Value in the initial stage.) Vibration resistance: No malfunction occurred in a one-sweep test between 8.3 and 000 Hz. Test was performed at both energized and deenergized states to the axis and right angle directions of the main valve and armature. (Value in the initial stage.) Pilot Valve/Spacifications Option Model Option/Interface Regulator Max. operating rate (1) (cycle/sec) Response time () (sec) or less 0.00 or less 0.05 or less 0.05 or less 0.06 or less Weight (3) (kg) (3) Weight without sub-plate (Sub-plate: 0.37kg) (4) (1) and () are the rates in the condition of controlled clean air SV SY SYJ SX VK VZ VF VFR VP7 VQC SQ VQ VQ4 VQ5 VQZ VQD VFS VS VS7 VQ7

14 VS7-8 Double Pilot Check Spacer/Series FPG Cyinder mid-stroke/long term retention possible. The use of the double pilot check spacer equipped with a built-in double check valve enables the cylinder to stop and remain at mid-stroke for long periods regardless of air leakage between the spool and sleeve. 3 Position Double Pilot Check Valve (Wedge packing style) VS7-8-FHG-D- R 3 position double pilot check valve achieves a reduction in air leakage as a result of main valve construction which features co-axial wedge packing (Max. leakage: cm 3 /min (ANR)). Double Pilot Check Spacer Specifications Double pilot check spacer model Applicable solenoid valve/air operated valve Leakage (cm 3 /min (ANR)) With one side solenoid energized. (With one side pilot air pressured) Both sides solenoids de-energized. (With both sides pilots not air pressured) Check Valve/Operation Pressure Characteristics The check valve will operate correctry providing that cylinder side pressure is not in excess of two times the supply pressure. P P A B VV7-FPG Series VS7-8/VSA7-8 R1 80 R R1 80 R R1 0 R Cylinder Speed/Stop Position Range Caution Verify that there is no leakage from the pipes between valve and cylinder, and from fittings. Check for leaks by using neutral detergent solution before use. Also check the cylinder packing and the piston packing. If there is leakage, cylinder may not stop at the mid-stroke position, and could move immediately after the valve is deenergized. Be aware that if the exhaust side is restricted excessively, the intermediate stopping accuracy will decrease and will lead to improper intermediate stops. Cylinder Operation Chart Cylinder ø st ø st Supply Load factor Load pressure ø50 ø80 0.MPa 5kg 51% 8%

15

16 VS7-8 Construction VS7-8-FG-S- -Q VS7-8-FG-D- -Q VS7-8-FHG- -Q VS7-8-FJG- -Q VS7-8-FPG- -Q VS7-8-FHG-D- R-Q Replacement Parts No. q w e r t y u i o Description Return spring Gasket Gasket Gasket Mini-Y-packing Pilot valve assembly Detent assembly Double pilot check spacer Packing Part No. Material VS7-8-FG-S VS7-8-FG-D VS7-8-FHG VS7-8-FJG VS7-8-FPG SUS NBR NBR NBR NBR AXT5-1 AXT5-13 AXT5-14- AXT MY-16N AXT5-13 AXT5-14- AXT MY-16N AXT5-1 AXT5-13 AXT5-14- AXT MY-14N AXT5-1 AXT5-13 AXT5-14- AXT MY-14N AXT5-1 AXT5-13 AXT5-14- AXT MY-14N NBR AXT511C- AXT511C- AXT511C- AXT5-9 AXT AXT511C- AXT511C- VV7-FPG

17 VS7-8 With Sub-plate/Dimensions VS7-8-FG-S- -Q VS7-8-FG-D- -Q SV SY SYJ SX VK VZ VF VFR VP7 VS7-8-FHG- -Q VS7-8-FJG- -Q VS7-8-FPG- -Q VQC SQ VQ VQ4 VQ5 VQZ VQD VFS VS VS7 VQ7 ( ): In case of direct manual override style

18 VS7-8 Without Sub-plate/Dimensions VS7-8-FG-S- Port size of sub-plate -Q VS7-8-FG-D- Port size of sub-plate -Q VS7-8-FHG- Port size of sub-plate -Q VS7-8-FJG- Port size of sub-plate -Q VS7-8-FPG- Port size of sub-plate -Q ( ): In case of direct manual override style. Note) Symbol EA and EB correspond to R1 and R respectively (R1=EA, R=EB)

19 VS7-8 Interface Speed Control Interface Speed Control/Dimensions AXT5-3A Interface Regulator Symbol Interface Regulator/Dimensions P port regulation/arb p SV SY SYJ SX VK VZ VF VFR VP7 Symbol P port regulation A port regulation A port regulation/arb a B port regulation/arb b VQC SQ VQ VQ4 VQ5 VQZ VQD VFS VS VS7 VQ7 B port regulation

20 Series VS7-8 Sub-plate Symbol Model Piping Port size VS7-- A03 A04 Side 3 8, 1 VS7-- B03 B04 Bottom VS7--A06 Side 3 4 VS7--B06 Bottom

21 Series VS7-8 Manifold Manifold: Series VV7 Note: Please note that single subplates and manifolds have changed colour from platinium silver to white as standard. Valves will remain platinium silver. Standard Specifications Manifold block size Applicable solenoid valve Number of stations A, B-port Piping P, R1, R-port Individual SUP spacer Individual EXH spacer Gallery blank disc (Differential pressure style) The manifold Series VV7 has a wide variety of functions and porting compatible with virtually any application need. Common EXH Style Every valve is supplied and exhausted by the same SUP and EXH ports running through the connected manifolds. This is the most popular configuration. When there are 5 or more stations operating simultaneously and pilot back pressure is 0.kgf/cm or more, it is recommended that all pilot EXH ports (PE) of the manifold base (4 on U side and on D side, total 6 ports) be opened. Also, use AN1-01 for silencer for pilot EXH. V Type V type allows combinations with valves of varying body size. ( Interface adapter plate VV7-V-1 ) Main EXH Back Pressure Block Style If there are many valve stations operating at the same time and main EXH back pressure may cause trouble, mount back pressure block plate ("AXT503-37A") to prevent effects of main EXH back pressure. ISO Size w Series ISO Size w 1 to 3 8, 1 1, 3 4 VV7-P- VV7-R- AXT A (for P port) AXT51-14-A (for R1, R port) Individual EXH Style Every valve has an independent EXH port of its own. An individual EXH spacer (VV7-R-03, 04) mounted on the manifold block allows each valve to exhaust individually. Individual SUP Style An individual SUP spacer (VV7-P-03, 04) mounted on the manifold-block allows each valve to be supplied individually. Multiple Pressure SUP Style Allows supply of or more different pressures to one manifold. Put in a gallery blank disc (AXT A) between the stations to operate at different pressures. When using a dual pressures supply, the pressure can be supplied from both the left and right sides of the manifold. If 3 or more pressures are supplied, pressure should be supplied from the spacer (VV7-P- ) port. Bottom Piping Style (3/8, 1/) When side piping appearance is not acceptable or space is limited, bottom piping for A or B ports is possible. SV SY SYJ SX VK VZ VF VFR VP7 VQC SQ VQ VQ4 VQ5 VQZ VQD VFS VS VS7 VQ7 Individual Pilot EXH Style If there are many valve stations operating at the same time or operation frequency is high, trouble caused by back pressure will be prevented by using individual pilot EXH style valve ("VS V")

22 VS7-8 VV R 04R 03L 04L 03Y 04Y 3 8 (Right) 1 (Right) 3 8 (Left) 1 (Left) 3 8 (Bottom) 1 (Bottom) Combination Note) When mixing, inscride a mark and designate a separate piping specification. E Without air release valve With air release valve 04D 04U 04B 06D 06U 06B 1 (Bottom) 1 (Top) 1 (Both sides) 3 4 (Bottom) 3 4 (Top) (Both sides) Without air release valve 0A CV 50/60Hz 00A CV 50/60Hz 4V DC 1V DC Others (50V or less) 1.19-

23 VS7-8 Manifold/Dimensions L: Dimensions Common EXH Size L L1 L L1 L n M if ld i ht l f l M (k ) Equation n: stations L1=56n+64 L=56n+80 n: stations L1=56n+90 L=56n+6 SV SY SYJ SX VK VZ VF VFR ( ): In case of direct manual override style. VP7 Individual SUP VQC Individual EXH Double pilot check SQ VQ VQ4 VQ5 VQZ VQD VFS VS VS7 VQ7 ( ): In case of direct manual override style

24 VS7-8 Manifold/Dimensions L: Dimensions V Type Size L L1 L L1 L n Equation n: stations L1=56n+64 L=56n+80 n: stations L1=56n+90 L=56n+6 ( ): In case of direct manual override style. Interface Speed Control Interface Regulator Bottom Piping ( ): In case of direct manual override style

25 Air Operated/SIZEqw SeriesVSA7-6/VSA7-8 VSA7-6-FG-D VSA7-6-FJG-D VSA7-8-FJG-D VSA7-8-FG-S Ordering source area code Code areas Japan, Asia - Australia E Europe N North America FG YZ FHG VSA7-6-FG-S VSA7-8-FG-D FJG FPG FIG E Passage symbol position 3 position Option Single (FG-S) Double (FG-D) Reverse pressure (YZ-S) Closed centre (FHG-D) Exhaust centre (FJG-D) Double pilot check (FPG-D) Pressure centre (FIG-D) Specifications Fluid Max. operating pressure Min. operating YZ-S, FG-S (1) pressure (3) Others Proof pressure Ambient and fluid temperature Lubrication Shock/Vibration resistance (4) Enclosure Manual override Pilot air pressure (3) Model Size q Series VSA 7-6 Air/Inert gas 1.0MPa 0.1MPa 0MPa 1.5MPa to 60 o C () Not required. 150/50m/s Dust proof Non-locking push style (Option) 0.1 to 1.0 to. MPa Note 1) Min. operating pressure should be equivalent to or lower than pilot supply pressure. Note ) Use dry air at the low temperatures. Note 3) Use controlled clean air. Note 4) Shock resistance: No malfunction resulted from the impact test using a drop impact tester. The test was performed on the axis and right angle directions of the main valve and armature, for both energized and de-energized states. (Value in the initial stage.) Vibration resistance: No malfunction occurred in a one-sweep test between 8.3 and 000 Hz. Test was performed at both energized and de-energized states to the axis and right angle directions of the main valve and armature. (Value in the initial stage.) No. of positions (Single) (Double) 3 (Closed) 3 (Exhaust) 3 (Pilot check) 3 (Pressure) (Reverse pressure) VSA7 6 8 How to Order Body size SIZEq SIZEw S D Model VSA7-6-FG-S VSA7-6-FG-D VSA7-6-FHG-D VSA7-6-FJG-D VSA7-6-FPG-D VSA7-6-FIG-D VSA7-6-YZ-S Pilot port position Single Double 1 Effective area (mm )(Nl/min) 7 (147.5) 7 (147.5) 5.5 (1374.) 7 (147.5) 0 (79.65) 5.5 (1374.) 7 (147.5) Pilot port position Pilot cover, PA/PB port Sub-plate, 14X/ 1Y port (PE port) Size w Series VSA 7-8 No. of positions (Single) (Double) 3 (Closed) 3 (Exhaust) 3 (Pilot check) 3 (Pressure) (Reverse pressure) 6 FG D 1 A03 Model VSA7-8-FG-S VSA7-8-FG-D VSA7-8-FHG-D VSA7-8-FJG-D VSA7-8-FPG-D VSA7-8-FIG-D VSA7-8-YZ-S Effective area (mm )(Nl/min) 58( ) 58( ) 58( ) 58( ) 40(159.30) 58( ) 58( ) Thread Rc (PT) F G (PF) N NPT T NPTF Port size Symbol A0 A03 A04 B0 B03 SizeqSeries VSA 7-6 Side piping 1 4 Side piping 3 8 Bottom piping 1 4 Bottom piping 3 8 SizewSeries VSA 7-8 Side piping 3 8 Side piping 1 Bottom piping 3 8 B04 Bottom piping 1 R port: 3 8 Option (Manual override) Without manual override M With manual override SV SY SYJ SX VK VZ VF VFR VP7 VQC SQ VQ VQ4 VQ5 VQZ VQD VFS VS VS7 VQ7

26 VSA7-6/VSA7-8 Air Operated/Dimensions SIZEq VSA7-6- FG-S- - YG SIZEw VSA7-8- FG-S- - YG SIZEq VSA7-6-FG-D- - SIZEw VSA7-8-FG-D- - ( ): In case of VSA7-8 FHG SIZEq VSA7-6- FJG - - FIG FHG SIZEw VSA7-8- FJG - - FIG SIZEq VSA7-6-FPG-FPG- - SIZEw VSA7-8-FPG-FPG- - ( ): In case of VSA

27 Air Operated: SIZEq Manifold Manifold: Series VVA71 Standard Specifications Manifold application example Manifold block size Applicable valve Stations Piping A, B port P, R1, R port Control unit Individual SUP spacer Individual EXH spacer Block plate (Differential pressure style) Including F.R. Unit (equivalent to stations). The manifold Series VVA71 has a wide variety of functions and piping, compatible with virtually any application. Common EXH Style Every valve is supplied and exhausted by the same SUP and EXH ports running through the connected manifolds. This is the most popular configuration. Multiple Pressure SUP Style Allows supply of or more different levels of pressures to one manifold. Put in a gallery blank disc (AXT50-14) between the stations to operate at different pressures. A dual pressure supply can be applied to both the left and right sides of the manifold. If 3 or more pressures are supplied, the individual SUP spacer should be used. How to Order VVA71... Stations 1 1 station... stations Including F.R. Unit ( stations) Piping (A, B port) 0R 1 4 (Right) 03R 3 8 (Right) 0L 1 4 (Left) 03L 3 8 (Left) 0Y 1 4 (Bottom) 03Y 3 8 (Bottom) C6R One-touch fitting ø6 (Right) C8R One-touch fitting ø8 (Right) CR One-touch fitting ø (Right) C6L One-touch fitting ø6 (Left) C8L One-touch fitting ø8 (Left) CL One-touch fitting ø (Left) Mix Indicate piping specifications. 5 03R 03D 1 A AP M MP F G C E ISO size 1 Series ISO size 1 1 to 1 4, 3 8 One-touch fitting: ø6, ø8, ø 3 8One-touch fitting: ø1 Air filter (Auto drain, Manual drain), Regulator, Pressure switch, Air release valve VV71-P- (0: 1 4,03: 3 8,C: ø) VV71-R- (0: 1 4, 03: 3 8, C: ø) AXT50-14 Bottom Piping Style/1/4, 3/8 (A, B port) When side piping appearance is not acceptable or space is limited, either some of, or all ports, can be arranged with bottom piping. Individual EXH Style An individual EXH spacer (VVA71-R- ) mounted on the manifold block allows each valve to exhaust individually. Individual SUP Style An individual SUP spacer (VVA71-P- ) mounted on the manifold block allows each valve to be supplied individually. 1 Pilot supply port Valve body side Manifold block side Piping (P, R1, R port) 03D 3 8 (Bottom) 03U 3 8 (Top) 03B 3 8 (Both sides) C1D One-touch fitting ø1 (Bottom) C1U One-touch fitting ø1 (Top) C1B One-touch fitting ø1 (Both sides) Mix Indicate piping specifications. Control Unit None Filter with auto drain, regulator, air release valve Filter with auto drain, regulator, air release valve, pressure switch Filter with manual drain, regulator, air release valve Filter with manual drain, regulator, air release valve, pressure switch Filter with auto drain, regulator (air release valve blank plate) Filter with manual drain, regulator (air release valve blank plate) Air release valve (filter, air release valve blank plate) Air release valve Indicate pilot supply port. 1 VSA7-6-FG-S-1 VSA7-6-FG-S SV SY SYJ SX VK VZ VF VFR VP7 VQC SQ VQ VQ4 VQ5 VQZ VQD VFS VS VS7 VQ7

28 VSA7-6/VSA7-8 Manifold/Dimensions L: Dimensions L L1 L n n: Station Equation L1=43n+64 L=43n+76 Common EXH Individual SUP

29 VSA7-6/VSA7-8 Manifold/Dimensions Control unit Interface Speed Control Bottom Piping L: Dimensions n: Station L L1 L n Equation L1=43n+64 L=43n+76 L L3=43n+11 Interface Regulator SV SY SYJ SX VK VZ VF VFR VP7 VQC SQ VQ VQ4 VQ5 VQZ VQD VFS VS VS7 VQ

30 Air Operated: SIZEw Manifold Manifold: Series VVA7 Standard Specifications Manifold block size Applicable valve Stations Piping Individual SUP spacer Individual EXH spacer A, B port P, R1, R port Block plate (Differential pressure style) Including F. R. Unit (equivalent to stations). The manifold Series VVA7 has a wide variety of functions and piping, compatible with virtually any application. Common EXH Style Every valve is supplied and exhausted by the same SUP and EXH ports running through the connected manifolds. This is the most popular configuration. ISO size Series ISO size 1 to VV7-P- VV7-R- AXT A (for P port) AXT51-14-A (for R1, R port) Individual EXH Style An individual EXH spacer (VVA7-R-03/04) mounted on the manifold block allows each valve to exhaust individually. Individual SUP Style An individual SUP spacer (VVA7-P-03/04) mounted on the manifold block allows each valve to be supplied individually V Type V type allows combinations with valves of varying body size. (Interface adapter plate VVA7-V-1) How to Order VVA7 Stations 1 1 station stations Piping (A, B port) 03R 3 8 (Right) 04R 1 (Right) 03L 3 8 (Left) 04L 1 (Left) 03Y 3 8 (Bottom) 04Y 1 (Bottom) Mix Indicate piping specifications. 5 03R 04D 1 Air release valve E Multiple Pressure SUP Style Allows supply of or more different pressures to one manifold. Put in a gallery blank disc (AXT A) between the stations to operate at different pressures. A dual pressure supply can be applied to both the left and right sides of the manifold. If 3 or more pressures are supplied, the individual SUP spacer (VV71-P- ) should be used. Bottom Piping Style/(3/8, /1) When side piping appearance is not acceptable or space is limited, A or B port can be arranged with bottom piping. 1 Pilot supply port Valve body side Manifold block side 1 4 Piping (P, R1, R port) 04D 04U 04B 1 (Bottom) 1 (Top) (Both sides) 06D 3 (Bottom) 06U 06B 3 4 (Top) 3 4(Both sides) Without air release valve With air release valve Indicates pilot supply port. 1 VSA7-6-FG-S-1 VSA7-6-FG-S-

31 VSA7-6/VSA7-8 Manifold/Dimensions Common EXH L: Dimensions Size L L1 L L1 L n n: Station Equation L1=56n+64 L=56n+80 L1=56n+90 L=56n+6 SV SY SYJ SX VK VZ VF VFR VP7 ( ): 3/4 Individual SUP VQC SQ VQ VQ4 VQ5 VQZ VQD VFS VS VS7 VQ7 ( ): 3/

32 VSA7-6/VSA7-8 Manifold/Dimensions V Type ( ): 3/4 Interface Speed Control L: Dimensions Size L L1 L L1 L Interface Regulator n n: Station Equation L1=56n+64 L=56n+80 L1=56n+90 L=56n+6 Bottom Piping ( ): 3/

33 Manifold Exploded View VS7-6 D side end plate assembly Tension bolt Manifold block assembly U side end plate assembly < End plate assembly > AXT50 A <Tension bolt part number > AXT50 34 End plate position L R L side R side P, R port size 0 03 C1 1/4 3/8 ø1 One-touch fitting Number of stations 3 For stations For 3 stations For stations < Manifold block assembly> AXT50 1A < Manifold block replacement parts > Part No. Description Qty. Material Wiring specification Cylinder port position AXT50-19 O-ring 4 NBR A B Side Bottom L R L side R side AXT50-0 AXT50-- O-ring Plate 1 NBR SPCC Cylinder port size 0 03 C6 Note 1) C8 Note 1) C Note 1) 1/4 3/8 ø6 One-touch fitting ø8 One-touch fitting ø One-touch fitting AXT50-31 M4 X 8 Gasket Oval countersunk head screw 1 NBR SWRH3

34 Manifold Exploded View VS7-8 D side end plate assembly Manifold block assembly U side end plate assembly < End plate assembly > <Manifold block assembly> AXT51 A AXT51 1A End plate position L R L side R side P, R port size C1 1/ 3/4 ø1 One-touch fitting Wiring specification A B Side Bottom Cylinder port position L R Cylinder port size L side R side /8 1/ < Manifold block replacement parts> Part No. Description Qty. Material AXT51-13 O-ring NBR AS568-0 O-ring 1 NBR AS O-ring NBR AXT51-5 Gasket 1 NBR AXT51-4 Plate 1 SPCC M4X Oval countersunk head screw SWRH3 AXT Connection fitting A AXT Connection fitting B AXT Hexagon socket head screw

35 ISO CNOMO Standard Solenoid Valve Metal Seal - SIZESqwe Series VS7 6 8 VS7 6 Size q VS7 8 Size w VS7 Size e Solenoid interface conforms to CNOMO. Manifold interface to ISO standards. Low power consuption: 1.8W per solenoid. Internal or external pilot supply. Available in ISO 1, and 3 sizes. Large flow capacity. Fast response and long life. position 3 position Single solenoid (FG-S) Double solenoids (FG-D) Closed centre (FHG-D) Exhaust centre (FJG-D) Standard Specifications Fluid Single position position Pressure centre (FIG-D) Air and inert gas 0.15 to to 0.9 Operating pressure (MPa) Double 3 position 0.15 to 0.9 Ambient and fluid temperature Max. 50 C Manual operation Non-locking Electrical entry DIN43650 connector Lubrication Unnecessary (Turbine oil class 1 - ISO VG3 if used) Enviromental protection rating IP65 Shock/Vibration resistance 300/50m/s Note 1) Shock resistance: No malfunction resulted from the impact test using a drop impact tester. The test was performed on the axis and right angle direction of the main valve and armature, for both energized and de-energized states. Vibration resistance: No malfunction occurred in a one-sweep test between 8.3 and 000Hz. Test was performed at both energized and de-energized states to the axis and right angle direction of the main valve and armature. (value in the initial stage.) Pilot Valve Specifications Rated voltage (V) 0V AC 50/60Hz, 00V AC 50/60Hz, 4V DC, 1V DC DC (W) 1.8 Power AC Inrush current (VA) 5.4 comsuption AC Holding current (VA) 3.6 Allowable voltage (V) -15% to +% of rated voltage Coil insulation Class B (130 C) or equivalent Model No. of positions Size q Model (Single) VS7-6-FG-S- -Q (Double) VS7-6-FG-D- -Q 3 (Closed centre) VS7-6-FHG-D- -Q 3 (Exhaust centre) VS7-6-FJG-D- -Q 3 (Pressure centre) VP7-6-FIG-D- -Q Size w (Single) VS7-8-FG-S- -Q (Double) VS7-8-FG-D- -Q 3 (Closed centre) VS7-8-FHG-D- -Q 3 (Exhaust centre) VS7-8-FJG-D- -Q 3 (Pressure centre) VS7-8-FIG-D- -Q Size e (Single) VS7--FG-S- -Q (Double) VS7--FG-D- -Q 3 (Closed centre) VS7--FHG-D- -Q 3 (Exhaust centre) VS7--FJG-D- -Q 3 (Pressure centre) VS7--FIG-D- -Q Flow (Nl/min) Max. operating frequency (Hz) Response time (Ms) Weight (g) SV SY SYJ SX VK VZ VF VFR VP7 VQC SQ VQ VQ4 VQ5 VQZ VQD VFS VS VS7 VQ

36 VS7 6 8 How to Order Valve EVS7 6 FG S 3 CV Q SIze 6 ISO 1 8 ISO ISO 3 Configuration Solenoid Voltage S Single FJG D Double 5 FG FHG FIG V AC, 50/60Hz 0V AC, 50/60Hz 4V DC 1V DC Others (50V or less) Order Made Contact SMC for other voltages (9) How to Order Sub-plate - Size q Specifications Applicable solenoid valve Sub-plate size Piping Weight ) All R ports: 3 8 ISO size 1 ISO size 1 Side piping, Bottom piping, kg How to Order Sub-plate E VS7 1 A0 Thread - Rc(PT) F G(PF) N NPT T NPTF Ordering source area code Code areas Japan, Asia - Australia E Europe N North America Piping and port size A0 Side 1 4 A03 Side 3 8 B0 Bottom 1 4 B03 Bottom 3 8 R port: 3 8 Dimensions Model EVS7-1-A0 EVS7-1-A03 EVS7-1-B0 EVS7-1-B03 Piping Side Side Bottom Bottom Port size P, A, B R1, R

37 ISO/CNOMO type VS7 6 8 Dimemsions with Sub-plate - Size q EVS7 6 FG S CV Q EVS7 6 FG D CV Q SV SY SYJ SX VK VZ VF VFR VP7 EVS7 6 FHG D CV Q EVS7 6 FJG D CV Q EVS7 6 FIG D CV Q VQC SQ VQ VQ4 VQ5 VQZ VQD VFS VS VS7 VQ

38 VS7 6 8 How to Order Sub-plate - Size w Applicable solenoid valve Sub-plate size Piping Weight ISO size ISO size Side piping: 3 8 1, 3 4 Bottom piping: 3 8 1, ( 3 8, 1 ) 1.9 ( 3 4 ) How to Order Sub-plate E VS7 A03 Thread - Rc(PT) F G(PF) N NPT T NPTF Ordering source area code Code areas Japan, Asia - Australia E Europe N North America A03 A04 A06 B03 Piping and Port size Side 3 8 Side 1 Side 3 4 Bottom 3 8 B04 Bottom 1 B06 Bottom 3 4 Dimensions Piping Port size A B C D E F G H J K L M N O P Q R S T U V W X Y EVS7--A03 Side A04 3 8, EVS7--B03 Bottom B04 EVS7--A06 Side EVS7--B06 Bottom 4-M6, 1 Deep 4-M6, 1 Deep

39 ISO/CNOMO type VS7 6 8 Dimemsions with Sub-plate - Size w EVS7 8 FG S CV Q EVS7 8 FG D CV Q SV SY SYJ SX VK VZ VF VFR VP7 EVS7 8 FHG D CV Q EVS7 8 FJG D CV Q EVS7 8 FIG D CV Q VQC SQ VQ VQ4 VQ5 VQZ VQD VFS VS VS7 VQ

40 VS7 6 8 How to Order Manifold Specifications ) These are available for ISO1 and ISO size manifolds and are common to those and on the VS7-6/8 and VQ7-6/8 series valves. For more details on Specificatios, options, how to order and dimensions please refer to these series. How to Order Manifold ) These are available for ISO1 and ISO size manifolds and are common to those and on the VS7-6/8 and VQ7-6/8 series valves. For more details on Specificatios, options, how to order and dimensions please refer to these series. Options ) These are available for ISO1 and ISO size manifolds and are common to those and on the VS7-6/8 and VQ7-6/8 series valves. For more details on Specificatios, options, how to order and dimensions please refer to these series. Dimensions ) These are available for ISO1 and ISO size manifolds and are common to those and on the VS7-6/8 and VQ7-6/8 series valves. For more details on Specificatios, options, how to order and dimensions please refer to these series

ISO Interface Solenoid Valve/SIZEq Metal Seal. Standard Specifications. Fluid Operating pressure. Ambient and fluid temperature

ISO Interface Solenoid Valve/SIZEq Metal Seal. Standard Specifications. Fluid Operating pressure. Ambient and fluid temperature ISO Interface Solenoid Valve/SIZq Metal Seal SeriesVS7-6 VS7-6-FPG-D VS7-6-FG-D Accessories Mounting bolt (with washer) Packing Indicator Iight Optional Specifications VS7-6-FG-S Note: Please note that

More information

ISO Interface Solenoid Valve/SIZEq Metal Seal. Standard Specifications. Fluid Operating pressure. Ambient and fluid temperature

ISO Interface Solenoid Valve/SIZEq Metal Seal. Standard Specifications. Fluid Operating pressure. Ambient and fluid temperature ISO Interface Solenoid Valve/SIZq Metal Seal SeriesVS7-6 VS7-6-FPG-D VS7-6-FG-D Accessories Mounting bolt (with washer) Packing Indicator Iight Optional Specifications VS7-6-FG-S Note: Please note that

More information

ISO Standard Solenoid Valve/SIZEq Rubber Seal Series VP7 6

ISO Standard Solenoid Valve/SIZEq Rubber Seal Series VP7 6 ISO Standard Solenoid Valve/SIZq Rubber Seal Series VP7 6 VP7 6 FPG D VP7 6 FG D position position Single solenoid (FG-S) Double solenoids (FG-D) Reverse pressure (YZ-S) Reverse pressure (YZ-D) Closed

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

5 Port Pilot Solenoid Valve Metal Seal. Configuration Voltage Electrical entry Option. Standard. 100V AC50/60Hz 200V AC50/60Hz 24V DC.

5 Port Pilot Solenoid Valve Metal Seal. Configuration Voltage Electrical entry Option. Standard. 100V AC50/60Hz 200V AC50/60Hz 24V DC. 5 Port Pilot Solenoid Valve Metal Seal SeriesVFS Models and Variations Body ported Base mounted Series VFS000 VFS2000 VFS3000 VFS2000 VFS3000 VFS4000 VFS5000 Port Size Effective area (mm 2 ) (Nl/min) 8:

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model 2 position 3 position

More information

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC)

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC) Port Solenoid Valve/Direct Poppet Rubber seal Series VK3000 Nl/min 147 Compact/Width 18 X Length 8 (mm) Low power consumption 4W DC (Standard) 2W DC (Energy saver) Standard copper free specification All

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I ISO Standard Solenoid Valve Series VQ7-6/7-8 (Size ) (Size ) Conforms to ISO Standard /I.0- Ideal for driving cylinders up to Large flow capacity ø00 (VQ7-6, Size ) ø60 (VQ7-8, Size ) Nl/min VQ7-6: 668.

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR2 JIS Symbol type

More information

Rubber Seal VP300/500/700

Rubber Seal VP300/500/700 Port Pilot Operated Poppet Rubber Seal 00/500/700 High flow capacity Cv1.0 (00), Cv. (500), Cv.0 (700) Low power consumption: 1.8W(DC) Possible to use as either selector valve or divider valve Changeable

More information

Manifold Specifications Stacking Type

Manifold Specifications Stacking Type Specifications Stacking Type Keeps environmental air clean from pilot exhaust Use of the VV5FS- manifold can exhaust intensively the pilot exhaust gas to the base side, and can prevent environmental aggravation

More information

Flow characteristics Max. (1) b Standard Specifications. P Manual override.

Flow characteristics Max. (1) b Standard Specifications. P Manual override. Port Direct Operated Solenoid Valve Series 0 Metal Seal Model Number of positions (Single) (Double) ( position) JIS Symbol Model Port size Rc (Nominal size) 0-0 8 ( A) 0- ( 8A) 0-0 8 (0A) 0-0 8 ( A) 0-

More information

5 Port Pilot Solenoid Valve Rubber Seal

5 Port Pilot Solenoid Valve Rubber Seal 5 Port Pilot Solenoid Valve Rubber Seal VF1000/3000/5000 Large flow capacity, Yet compact size. Low power consumption. 1.8WDC Exhausting equipment for pilot valve not required. Common exhaust for main

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

NAMUR Interface 5 Port Solenoid Valve

NAMUR Interface 5 Port Solenoid Valve NAMUR Interface 5 Port Solenoid Valve Series VFN000N 5 5 Specifications Valve Electrical entry Fluid Max. operating pressure Min. operating pressure Ambient and fluid temperature Lubrication Pilot operator

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Body Ported Base Mounted Series S000 S000 S000 S000 S000 S4000 S5000 Sonic conductance C [dm /s bar)] 4/ 5/(A/B R/R) Single Double.8.4

More information

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series VZS Series Variations Plug-in Type Base Mounted Type (With sub-plate) Non Plug-in Type Base Mounted Type (With sub-plate) Series Sonic conductance

More information

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Series VQ Rubber Seal Space-saving profile Clean space saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection Rubber Seal Port Solenoid Valve Series SJ000/000 Cassette Type Manifold 0 mm 7. mm (SJ000) 0 mm (SJ000) Non plug-in type Individual wiring manifold SJ000 SJ000 Can be mounted together. Connecter connection

More information

Series VQZ1000/2000/3000 Single Unit

Series VQZ1000/2000/3000 Single Unit +- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot 3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in

More information

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S. High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure of 0.5MPa, subject to clean, dry air) 4 Port Direct

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type20P 5 Port Solenoid Valve ody Ported Manifold ar Stock Type/Flat Ribbon Cable Series SY3000/5000/7000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 5 20P 05 Manifold series 3 SY3000

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

Manifold Specifications

Manifold Specifications Specifications Specifications Base mounted VVFR-01 VVFR- VVFR-0 Wiring With terminal block With multi-connector With D-sub connector Grommet terminal DIN terminal Grommet Grommet terminal Conduit terminal

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes

More information

Manifold Specifications

Manifold Specifications Specifications Plug-in Type: With Terminal Block Since lead wires of solenoid valve are connected with the terminals on upper surface of terminal block, corresponding lead wires from power source can be

More information

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm 4 Port Direct Operated Poppet Solenoid Valve Series D1000 High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type1P Type2P 5 Port Solenoid Valve ase Mounted Manifold ar Stock Type/Flat Ribbon Cable Series /5000/000 How to Order Manifold Type 1P/Compact style SS5Y 5 1P 05 C8 Manifold series 3 5, port size Thread

More information

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000) 5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust

More information

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing

More information

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Rubber Seal Series VQ Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

More information

Series SV1000/2000/3000/4000

Series SV1000/2000/3000/4000 Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Rubber Seal Port Solenoid Valve Series Manifold Single Unit ase Mounted Manifold VV01 V100 ar base P.18 ody Ported P.10 ase Mounted P.10 VQD VKF VK VT VS Separable base ody Ported Manifold P.1 Stacking

More information

ISO Interface. Large capacity. Light weight. Accommodates enclosure IP65. Solenoid Valve (with M Connector) Conforming to ISO

ISO Interface. Large capacity. Light weight. Accommodates enclosure IP65. Solenoid Valve (with M Connector) Conforming to ISO P-EX01-A Solenoid Valve (with M Connector) Conforming to ISO 1507-1, Large capacity EVS1-01 (Size: 01) EVS1-0 (Size: 0) Light weight Size 01 (-position): 0.6kg Size 0 (-position): 0.18kg Flow rate 1000L/min

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to

More information

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum 3 Port Direct Operated Poppet Rubber Seal Series 307 Large Flow Capacity, yet Compact Size. Dimensions (W X H X D) 30 X 54.5 X 33 307 Nl/min 206.02 or more, 1/4 Low Power Consumption /VO307 4.8W DC/Standard

More information

New Concept Connector Type Manifold

New Concept Connector Type Manifold New Concept Connector Type Manifold Series /000/3000/000 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration.

More information

Example. U side. Stations SY5000

Example. U side. Stations SY5000 45 Type 5 ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN ail Mounted/Individual Wiring Series SY3000/5000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 3 45 05 U C6 Example

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position

More information

A variety of circuits in simple construction Intermediate and emergency stops with a large size cylinder

A variety of circuits in simple construction Intermediate and emergency stops with a large size cylinder Power Valve 3 Position Valve Series VEX3 A variety of circuits in simple construction Intermediate and emergency stops with a large size cylinder System construction with VEX Conventional system construction

More information

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is. Port Solenoid Valve Series VQ 00 Unprecedented high speed, stable response, and extra-long service life. ON:.ms, OFF: ms, Dispension accuracy ±ms (With indicator light and surge voltage suppressor; supply

More information

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control Port Electro-Pneumatic Proportional Valve Series 000/000 Capable of actuating a cylinder and performing analog control of pressurization alone can be used to switch and actuate a cylinder and to perform

More information

Series SYA3000/5000/7000

Series SYA3000/5000/7000 Port Air Operated Valve Series SYA000/000/7000 How to Order A, B port size Thread type Thread piping (Inch size) - Rc Symbol Port size Applicable series Symbol Port size Applicable series F G SYA000 N

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Port Solenoid Valve Metal Seal Rubber Seal Series Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Vacuum Release Valve with Restrictor Series SJ3A6 SJ Plug-in Type Connector Connection P.86 D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Non Plug-in Type Individual

More information

SYA3000/5000/7000. How to Order SYA3000 SYA5000. Bracket One-touch fitting for ø8 G 1 4 With foot bracket. F1 One-touch fitting for ø8 SYA7000 G 1 8

SYA3000/5000/7000. How to Order SYA3000 SYA5000. Bracket One-touch fitting for ø8 G 1 4 With foot bracket. F1 One-touch fitting for ø8 SYA7000 G 1 8 Port Air Operated Valve SYA000/000/7000 How to Order Symbol M C6 01F C6 02F C10 Without bracket A/B port size Port size Series M One-touch fitting for ø4 SYA000 One-touch fitting for ø6 G 1 8 One-touch

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series

More information

5 Port Air Operated Valve. Specifications. Flow characteristics 1 4/2(P A/B) Cv

5 Port Air Operated Valve. Specifications. Flow characteristics 1 4/2(P A/B) Cv 5 Port Air Operated Valve Series 000 Model (With sub-plate) Valve model -M5 -M5 3-M5 -M5 --0 --0 --0 --0 3--0 3--0 --0 --0 position 3 position position 3 position Type of actuation Single Double Closed

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Series 000 Compact and lightweight: 3 mm width Compact yet provides

More information

Series SYJ300/500/700

Series SYJ300/500/700 ort Solenoid Valve ubber Seal Series SYJ00/00/00 Low power consumption: 0.W (Without light) (Current draw: 1m at 4V DC) Completely interchangeable ilot exhaust with the previous series VJ00/00/00 and VZ00/00.

More information

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A) ort Solenoid Valve ubber Seal Series SY00 Low power consumption: 0.W (Standard, Without light) (Current draw: m at V DC) Large flow capacity style:0.7w (Current draw: m at V DC) Body width: 0mm 7.8 Nl/min

More information

Series AV2000/3000/4000/5000

Series AV2000/3000/4000/5000 Soft Start-up Valve Series AV/3/4/5 Series introduced! A start-up valve that gradually increases supply pressure during start up and rapidly exhausts system air when the supply air is shut off AC AV AU

More information

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control Port Electro-Pneumatic Proportional Valve Series VER000/000 Capable of actuating a cylinder and performing analog control of pressurization VER alone can be used to switch and actuate a cylinder and to

More information

3/4/5-Port Solenoid Valves Precautions 1 Be sure to read this before handling products.

3/4/5-Port Solenoid Valves Precautions 1 Be sure to read this before handling products. Precautions 1 1. Confirm the specifications. Products represented in this catalog are designed only for use in compressed air systems (including vacuum). Do not operate at pressures, temperatures, etc.,

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 MPa Pilot Operated /3 Port Solenoid Valve & Check Valve VCH Series VCH4/4: Port VCH40: 3 Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve [Option] VCH40 Series Stable responsiveness Response

More information

Vacuum Equipment. Application. Series

Vacuum Equipment. Application. Series Equipment Series Application Page ejector In-line vacuum ejector Multistage ejector ejector with check valve Pad with check valve ejector for water soluble coolant removal ZH ZU ZL1/2 (Special order product)

More information

3 Port Air Operated Valve

3 Port Air Operated Valve Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation

More information

5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type. Closed Center DS3330/DS3300. How to Order - Body Ported Type

5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type. Closed Center DS3330/DS3300. How to Order - Body Ported Type 5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type COMPACT SIZE AND LIGHT WEIGHT LARGE FLOW CAPACITY LOW POWER CONSUMPTION DESIGNED FOR NON-LUBRICATED SERVICE DV000 Symbol Single DS330/ How

More information

Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero.

Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero. For General Purpose /3 Port Valve Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero. Wide variations Series For controlling pneumatic

More information

3 Port Solenoid Valve

3 Port Solenoid Valve 3 ort Solenoid Valve Series VKF300 ubber Seal Direct Operated oppet Type Compact yet provides a large flow capacity Body width 8 mm vailable in vacuum applications ( 0. ka) Can be used in vacuum/release

More information

Series SYA3000/5000/7000

Series SYA3000/5000/7000 Port Air Operated Valve Series SYA000/000/7000 How to Order A, B port size Thread type Thread piping (Inch size) Nil Rc Symbol Port size Applicable series Symbol Port size Applicable series F G M SYA000

More information

Series SY3000/5000 How to Order Manifold

Series SY3000/5000 How to Order Manifold Type N ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN Rail Mounted/Connector ox SY/ How to Order Manifold SSY SY SY Specifications Symbol Specifications With connector box (COM spec.) N With

More information

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04 Three functions (pressure regulator, switching valve, and speed controller) are provided by a single valve. The conventional valve combination circuit has been condensed into a single valve. A large capacity

More information

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110 Best 1 Pneumatics Transmitters Relay valve P. 1900 Side piping: 30 x 53 x 91 Bottom piping: 30 x 8 x 91 VR151 VR152 Effective area (mm 2 ) Number of ports Function 7 5 Metal Spool Shuttle valve P. 1902

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

5 Port Air Operated Valve. How to Order. Port size. (A, B port) R port of VFA3 70 is 1/4.

5 Port Air Operated Valve. How to Order. Port size. (A, B port) R port of VFA3 70 is 1/4. Port Air Operated Valve Series VFA000 How to Order Body ported single solenoid Foot bracket VFA22 Port size (P, A, B port) 0 8 4 R, R2 port are /8. F Thread type (Including pilot port) F N T Rc G NPT NPTF

More information

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles Port Solenoid Valve: ase Mounted Metal Seal/Rubber Seal Series VQ Space and capacity saving Pilot valve is gathered at one side. Space saving design which does not have any protrusions. Space saving Capacity

More information

Series SYA3000/5000/7000

Series SYA3000/5000/7000 1 Port Air Operated Valve Series SYA000/000/7000 Body ported Base mounted Base mounted How to Order A, B port size Thread type Thread piping (Inch size) Nil Rc Symbol Port size Applicable series Symbol

More information

Related Products VR4151/4152 Relay Valve

Related Products VR4151/4152 Relay Valve Related Products VR4151/4152 Relay Valve Appropriate output sequences are affected according to the signal received from the machanical valve. Specifications 1 Fluid Air Operating pressure 0 to 1.0MPa

More information

Process Valve/Series VN

Process Valve/Series VN For General Purpose /3 Port Valve Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero. Wide variations Series VNA For controlling pneumatic

More information