Integral Fitting Type (Hyper Fittings) How to Order Valves (Single Type) Material. Symbol N PFA F PFA
|
|
- Silvia Kristin Henderson
- 5 years ago
- Views:
Transcription
1 Integral Fitting Type (Hyper Fittings) Series LVC ody class pplicable tubing size Connecting tubing O.D. Metric sizes Inch sizes ody class ø ø ø8 ø0 ø ø9 ø /8 / / /8 / / asic size Orifice dia. ø ø8 ø0 ø ø ody class With reducer How to Order Valves (Single Type) LVC 0 S 0 0.O. ote) Refer to variations in the table below for valve type combinations. ort (OUT) different dia. size Refer to the applicable tubing table to the left. pplication orts & same size Different diameter tubings can be selected within the same body class. Variations Type asic type With flow rate adjustment With by-pass With flow rate adjustment & by-pass With indicator Material ody F F F F ody class,,,,,, Option ilot port thread type.o. Orifice diameter Tubing O.D. Metric Inch.O. ctuator section End plate S VDF S LVC0 ø, /8, /, / one With flow rate adjustment With by-pass With flow rate adjustment & by-pass With indicator ote) Refer to Variations in the table below for option combinations. Options can not be combined each other. Diaphragm TFE TFE TFE Thread type M Rc /8 T /8 LVC0 ø8, 8, 0 /, /8 pplicable option LVC0 ø0 0, /8, / ote Hydrofluoric acid compatible (Only LVC0, 0 type) mmonium hydroxide compatible LVC0 ø, 9 /, / LVC0 ø 9, /, VC VDW VQ VX VX VX VX V LVC LV LVH LVD LVQ LQ LV TI/ TIL X 7--7
2 Standard Specifications Tubing O.D. Orifice diameter Flow v x 0 - m characteristics Cv Withstand pressure (Ma) Operating pressure (Ma) ack pressure (Ma) Metric size Inch size /.O. Valve leakage (cm /min) ilot air pressure (Ma) ilot port size Fluid temperature ( C) mbient temperature ( C) LVC0 / ø LVC0 0 /8 ø to or less 0. or less LVC0 / ø0 0. M Rc /8, T /8 0 (with water pressure) 0. to 0. 0 to 00 0 to 0 LVC0 9 / ø 0 to or less 0. or less LVC0 ø 9 8 Weight (kg) ote ) Contact if the valve is to be used with vacuum and flow. Different Diameter Tubing pplicable with Reducer Different diameter tubing can be selected (within a body class) by using a nut and insert bushing (reducer). With reducer Tubing O.D. ody Metric sizes Inch sizes class /8 / / /8 / / ote) Refer to page 9 for information on changing tubing sizes. Specific roduct recautions e sure to read before handling. Refer to page 7-- for Safety Instructions and 7-- to 7-- for High urity Chemical Valve recautions. Caution iping. Connect tubing with special tools. Refer to pages 7-- through 7--7 regarding tubing connection and special tools.. Tighten the nut to the end surface of the body. s a guide, refer to the proper tightening torques shown below. Tightening torque for piping ody class Torque (m) 0. to to.0.0 to.. to.0. to
3 Integral Fitting Type Series LVC Suck ack change of volume inside the suck back valve pulls in liquid at the end of the nozzle to prevent dripping. Single type Unit type djustment knob djusts the amount of suck back. Lock nut Locks the adjustment knob position. Options djustment knob djusts the amount of suck back. Lock nut Locks the adjustment knob position. djustment knob djusts the flow rate. Lock nut Locks the adjustment knob position. Suck back body With flow rate adjustment The flow rate is adjusted by controlling the diaphragm stroke. djustment knob djusts the flow rate. Lock nut Locks the adjustment knob position. Standard Specifications ote ) Tubing O.D. Orifice diameter Flow characteristics How to Order LVC S 0 ody class U ody class Suck back valve ody type Single type Unit type with way valve Metric sizes Inch sizes v x 0 - m Cv Withstand pressure (Ma) Operating pressure (Ma) Maximum suck back volume (cm ) ilot air pressure (Ma) ilot port size Fluid temperature ( C) mbient temperature ( C) Weight (kg) LVC LVCU (), (/8), (/), / pplicable tubing size Connecting tubing O.D. Metric sizes 0 0 Inch sizes With by-pass small amount of fluid from the inlet side is allowed to flow continuously to the outlet side by providing a by-pass inside the body to to 0. M 0 to 00 0 to 0 ort (OUT) different dia. size Refer to the applicable tubing in the table below. ø ø /8 / / asic size ø ote ) Different diameter tubing shown in ( ) can be selected when used with a reducer. Refer to page 7-- for details. pplication orts & same size Different diameter tubing can be selected within the same body class. ody class With reducer VC VDW VQ VX VX VX VX V LVC LV LVH LVD LVQ LQ LV TI/ TIL X djustment handle djusts the flow rate. Lock nut Locks the adjustment knob position. 7--9
4 Construction Standard type type.o. type type With reducer With flow rate adjustment With by-pass Suck back (single type) Suck back (unit type) With indicator arts list o. Description Material Option ctuator section S VDF ody F Diaphragm TFE End plate S VDF Insert bushing F 7 ut Collar F F 8 9 Flow rate adjuster section Indicator S 7--0
5 Integral Fitting Type Series LVC asic type VC L D VDW VQ -øm K VX VX Sensor (reathing port) R -Q VX VX V C G H LVC LV LVH J E LVD (F) LVQ LQ LV TI/ TIL LVC 0 LVC LVC LVC C D 8 8 E. F 79 0 G 8. 8 H J K 0 L M Q M x 0.8 Rc /8 T /8 (mm) R M x 0. Rc /8 T /8 X LVC
6 With flow rate adjustment With by-pass With flow rate adjustment & by-pass With indicator Suck back (Single type) Suck back (Unit type) 7 0 W (Max. S) (Max. S) (mm) (Max. T) S LVC. (mm) LVC T LVC 9 LVC 9. LVC. LVC. LVC LVC 0. (Max. T) S LVC LVC 9 LVC. (mm) T (mm) W LVC0 LVC0 90 LVC0 0. LVC0 7 LVC ø. 0 (Max..) M x 0.8 M x (Max..) M x (78).. (0) 7--
7 Manifolds Manifold Specifications ody class ody class Orifice dia. ø ø8 ø0 ø ody class 0.O. ody type Stacking type for manifold How to Order Manifold ase LLC 0 S ody class ase type Stacking type Manifold stations 0 stations 0 LVC 0 How to Order Valve Tubing size S0 S0 S0 S0 S07 S0 S07 S08 S0 S S0 S S S S S S9 LLC LLC LLC Manifold type (I), (OUT) type Valve stations Stacking type Common I/Individual OUT to stations Tubing size (port ) Tubing size (port ) /8 / / /8 / / ote ) Contact if the manifold will be used with vacuum and flow. stations S07 Tubing size /8" Ø /" Ø /" Ø /" Ø8 Ø0 /8" Ø0 /8" Ø /" Ø /" Ø9, /" Tubing size for port and L side connection Tubing size lug Ø /" Ø8 Ø0 /8" Ø0 ody class to /8" Ø 9 9 /" Ø /" Ø9, /" Ø /" Ø9, /" ody class Option Material F one With flow rate adjustment With indicator ilot port thread type ody F F F ctuator section End plate S VDF S ody class // // Diaphragm TFE TFE TFE Thread type M Rc /8 T/8 pplicable option LLC / / Tubing size for port and R side connection Tubing size lug Ø /" Ø8 Ø0 /8" Ø0 ody class to /8" Ø 9 9 /" Ø /" Ø9, /" Ø /" Ø9, /" ote) Options can not be combined each other. ote Hydrofluoric acid compatible (Only LVC0, 0 type) mmonium hydroxide compatible 7-- VC VDW VQ VX VX VX VX V LVC LV LVH LVD LVQ LQ LV TI/ TIL X
8 How to Order Manifold ssembly (Example) Enter the part number of the valves to be mounted together with the manifold base part number.... Stations Manifold variations Type Orifice diameter Manifold material Tubing size LVC0 / Ø LVC0 LVC0 F /8 / Ø8 Ø0 LVC0 / Ø asic type <Example> LLC-0-S set Stations are counted from station on the left side, with the (OUT) ports in front. (OUT) port set Manifold base part no. LVC0-S07- sets sets Valve part no. (stations & ) LVC0-S07 set set Valve part no. (station ) With flow rate adjustment.o..o. dd the symbol at the beginning of part numbers for valves, etc. to be mounted. Enter together in order counting from station on the left side, with the (OUT) ports in front. LLC- Stations --C Y -Mounting hole for W E (Max. S) U C H V G D K L L L -Q reathing port: R /8 / / / LLC. LLC 7 LLC 0 LLC C D E itch = n- port G H K Q M x 0.8 Rc /8 T /8 R M x 0. Rc /8 T /8 S. 9. U V 7. (mm) W Y M. M. M 7. M 7. LLC LLC LLC LLC Station L L L L L L L L L L L L (mm)
9 ort Standard Specifications LVC00 Orifice diameter ø Flow characteristics v x 0 - m Cv Withstand pressure (Ma) VC VDW Operating pressure (Ma) Valve leakage (cm /min) ilot air pressure (Ma) ilot port size Fluid temperature ( C) mbient temperature ( C) Weight (kg) 0 to 0. 0 (with water pressure) 0. to 0. M x to 00 0 to VQ VX VX VX VX How to Order Valve V LVC R ody class LVC 0 0 S 07 ody class Orifice dia. Ø 0.C pplicable tubing size Connecting tubing O.D. Metric sizes 0 0 Inch sizes ø ø /8 / / asic size ody class With reducer LV LVH LVD LVQ LQ LV TI/ TIL Construction X arts list o. Description ctuator section ody Diaphragm End plate ut Insert bushing Material S F TFE S F F 7--
10 0 R M x 0.8 ilot port M x 0. reathing port ø
High Purity Chemical Valve
High urity hemical Valve Series LV/LV/ Integral Fittings/Threaded orts/manual Operation (Integral Fittings/Threaded orts) Series LV ir Operated Type Integral Fittings Series LV /.O. with same configuration/double
More informationSpace saving, compact model available
Compact Type High Purity ir Operated Chemical Liquid Valve Series RoHS LV Space saving, compact model available Compact type model is introduced as a new series to complement current series with integrated
More informationHigh Purity Chemical Valve Compact Type. Space saving, compact type is available. Piping from 4 directions are possible.
High Purity Chemical Valve Compact Type Series Space saving, compact type is available. Compact type is introduced as a new series to complement conventional Series with integral fittings. Select a series
More informationHigh Purity Chemical Valve
T.S70- -U High urity hemical Valve Integral Fittings Series LV /.O. with same configuration/double ompatible with 00 fluid temperature ew ody material: ew F Series LV port added Threaded orts Series LV
More informationSeries VVXA21/22. Direct Air Operated 2 Port Valve/Manifold For Air, Gas, Vacuum and Oil VC VDW VQ VX2 VX VX3 VXA VN LVC LVA LVH LVD LVQ LQ LVN PA PAX
The VX series will be revised shortly. 1 Direct Operated 2 Port Valve/ For, Gas, Vacuum and Oil Series VVXA21/22 Common SUP type and individual SUP type (for vacuum use) standard models Compatible with
More informationDirect Air Operated 2 Port Valve/Manifold For Air, Gas, Vacuum and Oil
The VX series will be revised shortly. 1 Direct Operated 2 Port Valve/ For, Gas, Vacuum and Oil Series VVXA21/22 Common SUP type and individual SUP type (for vacuum use) standard models Compatible with
More information4/5 Port Air Operated Valve. SYJA3000 Series. How to Order. (Manifold use only) Type of actuation. 2 position single. 3 position closed center
4/ ort ir Operated Valve SYJ000 Series How to Order ody ported SYJ M racket Nil Without bracket F With bracket *Refer to page 47 for the details of the brackets. ase mounted (4 port) SYJ 2 0 (Manifold
More information2 Port Solenoid Valve For Dust Collector
The VX* series will be revised shortly. 2 Port Solenoid Valve For Dust Collector Series 2 port solenoid valve for dust collector Series In this L-shaped 2 port valve, the bag filter is cleaned by high
More informationPilot Operated 2 Port Solenoid Valve for Dry Air
Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0
More informationD-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000
D-sub Connector J Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000//000 Number of connectors: pins MIL-C-08 Conforming to JIS-X-0 --6 For details
More information5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted
Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted
More information5 Port Solenoid Valve
ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series
More informationSeries VQZ1000/2000/3000 Single Unit
+- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body
More informationPVC Quick Drain Valve
PVC Quick Drain Valve LVW Series Complies to JIS standard for polyvinyl chloride piping (JIS K 6742) Applicable fluids: Deionized water, Chemical liquids Application Example Cleaning Equipment Process
More informationSeries LVQ. Constructed without screws. Air Operated Chemical Valve Non-Metallic Exterior. Space Saving Type
ir Operated hemical alve on-etallic Exterior Series LQ onstructed without screws on-metallic construction without using metal screws to fasten the body of the actuator. ody section Integral fitting construction
More information5 Port Solenoid Valve
ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and
More informationAir Operated Chemical Valve Non-Metallic Exterior
T.ES0- -K ir Operated hemical alve on-etallic Exterior onstructed without screws on-metallic construction without using metal screws to fasten the body of the actuator. ody section ctuator section ody:
More information5 Port Solenoid Valve
Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size
More information5 Port Mechanical Valve
RoHS Compact design, large flow capacity mm 2 High cycle rate, long life/00 c.p.m. or less iping possible to any EXH port. roper countermeasures can be taken for applications in which the noise of the
More informationVQ1000. How to Order Manifold. Kit type
- - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold
More informationGateway System Serial Transmission System
Gateway System Series 00 I compliant V S000 C Tie-rod base Z pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000/000/000 Number of output points: points Connected to the 00GW
More informationISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I
ISO Standard Solenoid Valve Series VQ7-6/7-8 (Size ) (Size ) Conforms to ISO Standard /I.0- Ideal for driving cylinders up to Large flow capacity ø00 (VQ7-6, Size ) ø60 (VQ7-8, Size ) Nl/min VQ7-6: 668.
More information4/5 Port Solenoid Valve
ubber Seal / ort Solenoid Valve Series 000 / 000 / 000 [Option] SJ SY SV SZ V S000 VQ VQ VQ VQC VQZ SQ VFS VF VQ Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread
More information5 Port Solenoid Valve
ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high
More informationSeries SY3000/5000/7000
Type20P 5 Port Solenoid Valve ody Ported Manifold ar Stock Type/Flat Ribbon Cable Series SY3000/5000/7000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 5 20P 05 Manifold series 3 SY3000
More information3 Port Air Operated Valve. SYJA300 Series. How to Order. Nil Without sub-plate. Type of actuation. Normally closed Normally open
3 ort ir Operated Valve SYJ300 Series How to Order SYJ3 M3 Bracket Nil Without bracket F With bracket *The bracket is not mounted. *The bracket cannot be retrofitted later. SYJ3 Type of actuation Normally
More informationI N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications
I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000
More informationVXP21/22/23 Series. Pilot Operated 2 Port Solenoid Valve. For Air, Gas, Steam, Water and Oil VX2 VXK VXD VXZ VXS VXB VXE VXP VXR VXH VXF VX3 VXA
Pilot Operated Port Solenoid Valve VXP//3 Series For ir, as,, Water and Oil Variations.O..C. Wide variations of combination. ble to control a wide variety of fluids. Valve can be matched to particular
More informationRubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot
ubber seal ort ilot Solenoid Valve Series SYJ00 Specifications efer to www.smcworld.com for details of products compatible with overseas standards. Body ported Base mounted Fluid Operating pressure range
More information3 Port Solenoid Valve
ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M. V3 Cover
More informationNormally Closed Type High Vacuum Straight Solenoid Valve. How to Order XSA S 5 G. Fitting size. Fitting Type
Series XS Normally losed Type igh Vacuum Straight Solenoid Valve ow to Order [Option] Normally closed high vacuum straight solenoid valve XS 1 1 S Solenoid size 1 No.1 No. No. 1 Orifice symbol ø ø ø4.
More informationSeries SYJ300/500/700
ort Solenoid Valve ubber Seal Series SYJ00/00/00 Low power consumption: 0.W (Without light) (Current draw: 1m at 4V DC) Completely interchangeable ilot exhaust with the previous series VJ00/00/00 and VZ00/00.
More informationStandard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve
Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective
More informationCable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308
Cable ppendix Cable ppendix Multi-way cables The multi-pole connector cables used on SMC valves are common across several ranges. Cables are available in accordance with the MIL standard C-08 and also
More information2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating
/ ort Solenoid Valve ubber Seal Series SYJ000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Specifications JIS Symbol port port (manifold) position
More informationTerminal Block Box (Spring Type) SY3000/5000/7000 Series
INFORMATION 5 ort olenoid alve Terminal lock ox (pring Type) Y3000/5000/7000 eries Compact RoH Height 6.7 mm shorter (Approx. 9% reduction) Installation area of the terminal block box Reduced by approx.
More informationPilot Operated 2 Port Solenoid Valve for Dry Air
Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible
More informationAir Valve AIR-PILOTED VALVES
K-UV002 Ver.1.0 ir Valve I-ILOTED VLVES INSTUCTI MNUL Ver.1.0 ir-piloted Valves Features Since the unit requires air piping only, with no need for electrical wiring, it can be handled by a person without
More information5 Port Mechanical Valve Metal Seal. Specifications Fluid. Basic Roller lever. Mechanical operation. One way roller lever.
5 ort Mechanical Valve Metal Seal Compact design, large flow capacity 9.9 mm High cycle rate, long life/00 c.p.m. or less iping possible to any EXH port. roper countermeasures can be taken for applications
More information4/5 Port Solenoid Valve
CT.ES8 / ort Solenoid Valve Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M.7 to M2. 앬 Flow Characteristics Series Cover (stainless
More informationBase Mounted Plug-in/Plug Lead: Single Unit
ase mounted VQ ase Mounted lug-in/lug Lead: Single Unit Model Number of solenoids Model Single Metal seal VQ Rubber seal VQ ouble Metal seal VQ Rubber seal VQ Closed Metal seal VQ VQ center Rubber seal
More informationSeries SY3000/5000/7000
Type1P Type2P 5 Port Solenoid Valve ase Mounted Manifold ar Stock Type/Flat Ribbon Cable Series /5000/000 How to Order Manifold Type 1P/Compact style SS5Y 5 1P 05 C8 Manifold series 3 5, port size Thread
More informationMRK 25 M a r k 2 5 d i r e c t s o l e n o i d a c t u a t e d v a l v e s T C H N C L T V L V M
MRK 25 SRS direct solenoid actuated valves MRK 25 MRK 25 M a r k 2 5 d i r e c t s o l e n o i d a c t u a t e d v a l v e s T C H N C L T................................................... 3 V L V M O
More informationPower Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit
CT.EUS8 UK ower Consumption / ort Solenoid Valve With ower Saving Circuit Series SYJ000/000/7000 Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced
More information5.2 to 79 gpm 3000, 3600, 5000 psi
Modular Valve Series Modular Valve Series. to 79 gpm 000, 600, 000 Overview he modular valve is designed and engineered to integrate multiple hydraulic valve operations into a single unit, which eliminates
More informationMARK 15 SERIES. direct solenoid actuated valves
MRK 15 SRIS direct solenoid actuated valves M a r k 1 5 d i r e c t s o l e n o i d a c t u a t e d v a l v e s T C H N I C L D T................................................... 3 V L V M O D L S L
More informationVacuum Pad with Ejector
IFORMTIO Vacuum ad with Ejector ad Diameter: ø63, ø8 RoHS Ejector and pad are integrated. Space saving and reduced piping labor! Bellows type with groove Two-stage ejector More efficient ejector Suction
More information3, 5 port pilot operated valve Pneumatic valve / master valve. Discrete valve. Manifold
K/K, pilot operated valve neumatic valve / master valve MNE0 MNE0 M MN W WG MNS0 MNS0 T L-/ S/0 S/ K/ F CONTENTS Safety precautions 776 Discrete valve ody ing (K/K to ) 868 Sub-plate ing (K to ) 87 Manifold
More informationNew Products. 3 Port Solenoid Valve with Spool Position Detection SNP Series
New roducts 3 ort Solenoid Valve with Spool osition Detection SN Series New roduct Reliable detection of open and close status by spool position detecting. Two safety cut off by modular connection! Main
More informationPilot Operated/Zero Pressure Differential Operation
ilot Operated/Zero ressure ifferential Operation 2 ort Solenoid Valve Series Z Change of valve style from.c. to.o. is simple. xcellent maintainability Separation of movable iron core and diaphragm valve
More information3 Port Solenoid Valve
3 ort Solenoid Valve Series VKF300 ubber Seal Direct Operated oppet Type Compact yet provides a large flow capacity Body width 8 mm vailable in vacuum applications ( 0. ka) Can be used in vacuum/release
More informationVacuum System Peripherals
Vacuum System Peripherals Vacuum Regulator/Electronic Vacuum Regulator Vacuum regulator: IRV0/0 Electronic vacuum regulator: ITV009/ITV09 Directional Control Valve Selection guide of directional control
More informationCompact Vacuum Ejector
Compact acuum Ejector Series ZA Total length Total width 7.9 mm 9.9 mm Total height. mm Response time 0 ms Response time for up to 0 ka Nozzle diameter: ø0.7 iping: ø/ø. x 0 mm Able to install on the moving
More informationExample. U side. Stations SY5000
45 Type 5 ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN ail Mounted/Individual Wiring Series SY3000/5000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 3 45 05 U C6 Example
More informationSpace Saving Vacuum Ejector/Vacuum Pump System
Space Saving acuum Ejector/acuum ump System Series Current 21.6 mm mm Width mm [Option] Weight 9 g Single unit with vacuum pressure switch and suction filter ZK2 ZR Z Z ZM ZL -X267 ZU Ejector.2 ump System.118
More informationSeries SYJ3000/5000/7000
, ort Solenoid Valve ubber Seal Series SYJ000/000/7000 Low power consumption: 0.W(Without light) (Current draw: 1m at V DC) right color tone and state of the art design SY SYJ SX VK VZ VF VF V7 V Completely
More informationFloat Valve MODEL. Schematic Diagram. Optional Features. Typical Applications. Installation. Product Dimensions Data:
2 CF1-C1 Float Control 124-01 (izes 1/2"- 6" Full Internal ort) 624-01 (izes 3"- 8" Reduced Internal ort) Float Valve On-Off or Non-Modulating ction Fully djustable High and Low Level ettings imple Design,
More informationLarge Size Vacuum Module:
arge Size acuum Module: Ejector System/acuum ump System arge suction flow rate, suitable when used with large size pads or multiple pads. Nozzle dia. ø., ø., ø.5, ø.8, ø2. acuum module suitable for handling
More information2/3 Port Valve for Various Fluids Control
Equipment for Fluid Control 2/ Port Valve for Various Fluids Control 2/ Port Solenoid/ir Operaed Valve for Various Fluids Control (For Water/ir/Oil/Gas/Vacuum/Steam) 2/ Port Solenoid Valve Direct operated
More informationQ1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.
Multistage Ejector 112/212 Series Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus
More informationRA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.
R 26 404/06.9 ccumulator unloading valve, pilot operated, Model D 6 V.., series 4X Size 6 up to 4500 SI (315 bar) up to.00 GM (30 L/min) R 26 404/04.9 Features: For subplate mounting: porting pattern to
More informationSpace Saving Vacuum Ejector / Vacuum Pump System
CT.US0-1'-UK Space Saving acuum jector / acuum ump System Conventional ZX 21. mm mm ZQ Series ZQ Width mm Weight 9 g Single unit with vacuum pressure switch and suction filter jector ump System NW asy-to-use
More information3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)
ort Solenoid Valve ubber Seal Series SY00 Low power consumption: 0.W (Standard, Without light) (Current draw: m at V DC) Large flow capacity style:0.7w (Current draw: m at V DC) Body width: 0mm 7.8 Nl/min
More informationDiscrete direct acting 3 port solenoid valve (general purpose valve) AG31/AG41 Series. Universal type Port size: Rc1/8, Rc1/4, Rc3/8
G3141 Series iscrete direct acting 3 port solenoid valve (general purpose valve) G31/G41 Series Universal type Port size: Rc1/8, Rc1/4, Rc3/8 JIS symbol G31/41: Universal type COM NO NC Common specifications
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time
More informationHigh purity gas control systems
Process Gas and Vacuum Components High purity gas control systems DRY FINE SYSTEM C-035 C-035 Opening Up the Future for Process Control Product level controlol Part level control Cleanness control Manufacture
More informationCheck Valves. VC Series - Cartridge Mounting 500 Bar. Innovative Fluid Power. Bulletin 86624
VC Series - Cartridge Mounting 500 ar Innovative Fluid Power ulletin 86624 Issue 1.0 02.2010 VCC 500 ar General Information Check Valve with Standard Top Cap Section View with Standard Poppet Maximum Working
More informationSingle Solenoid External Pilot Normally Closed
atalog 000- Operating ressure Internal ilot Solenoid Valves 3/" & 3/" ody 0 to 0 SI (standard) -/" ody to 0 SI (00 SI option available) Series Valves ilot Supply Internal ilot Remote ilot Valve Operating
More informationPower Valve Precision Regulator
Power Valve Precision Regulator VEX Series High precision, large capacity relief regulator port large exhaust capacity pressure reducing valve which utilizes a nozzle flapper mechanism available as air
More information2/2-way Angle-Seat Control Valve with stainless steel design for media up to +180ºC, DN 13-50
2/2-way ngle-seat Valve with stainless steel design for media up to +180ºC, DN 13-50 Excellent control characteristic and high fl ow rates High cycle life Clean design for optimal use in hygienic environment
More informationGeneral purpose direct acting 2, 3 port solenoid valve
eneral purpose direct acting, 3 port solenoid valve (eneral purpose valve) eneral purpose Direct acting, 3 port solenoid valve / Pilot operated/pilot kick type port solenoid valve P/D/PK/DK Page 9 9 P/
More informationAir Service Units Filter pressure regulator + Lubricator - Size 1. Series Technical characteristics. Construction and working characteristics
ir Service Units Filter pressure regulator + Lubricator - Size Series 00 Construction and working characteristics - Zinc alloy body or reinforced technopolymer body with threaded brass insert connections.
More informationIsys Micro Series. Valve Products. Operating information. Material specifications. Pilot configuration
atalog 000-3US The Valve System incorporates a space saving back to back valve mounting design, and achieves flow rates of 0.35 v per valve with valves having a combined width of mm. This plug-in valve
More informationMARK 8 SERIES. direct solenoid actuated valves MARK 8
SERIES direct solenoid actuated valves M a r k 8 d i r e c t s o l e n o i d a c t u a t e d v a l v e s T E C H N I C L D T................................................... 3 V L V E S M O D E L S E
More informationHigh Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves
igh Response ype roportional Electro-ydraulic s igh response, high precision and high reliability are achieved by a combination of compact and powerful solenoid and spool-position-detection LVD. Direct
More informationEasier maintenance. ZHP Series. Mounting with the lock plate reduces the pad replacement work steps! Uses an isolated structure. Application Examples
Vacuum ad with Ejector Series ad Diameter: ø63, ø8 Ejector and pad are integrated. Space saving and reduced piping labor! Two-stage ejector More efficient ejector Suction flow rate 1) Compared with SMC
More informationTube Applicable for nylon, soft nylon and polyurethane tubing.
Miniature Fittings Series M pplicable Tubing: ø3.2, ø4, ø6 onnection Thread:, M, arb onfiguration for easy insertion into the tube Holds the tube tightly ody With electroless nickel plated Low tightening
More informationMMD. Chemical liquid manual valve/toggle valve/flow control valve. Overview. Features FMD00
Chemical liquid manual valve/toggle valve/flow control valve MMD Overview This chemical liquid manual valve for semiconductor manufacturing equipment is available in 1/8 to 1 inch port sizes and different
More informationCompact Proportional Solenoid Valve
Compact Proportional Solenoid Valve Series Repeatability: % or less Hysteresis:1% or less Fluid Flow rate control range Note) Series Air, Inert gas to L/min to L/min Note) Varies depending on the model.
More informationMiniature Fittings Series M
Miniature Fittings Series M pplicable Tubing: Ø 3.2, Ø 4, Ø 6 onnection Thread:, M, arb onfiguration for easy insertion into the tube Holds the tube tightly ody With electroless nickel plated Low tightening
More informationDiscrete direct acting 2 port solenoid valve (general purpose valve) AB31 AB41 Series NC (normally closed) type AB42 Series NO (normally open) type
31414 Series iscrete direct acting port solenoid valve (general purpose valve) 31 41 Series NC (normally closed) type 4 Series NO (normally open) type Port size: Rc1/8 to Rc1/ JIS symbol Common specifications
More informationNO (normally closed) type Common supply type (port C pressurization) MPa MPa MPa C C
Direct acting port solenoid valve, manifold and actuator (general purpose valve) NO (normally closed) type Common supply type (port C pressurization) Manifold circuit structure Common specifications B
More informationMYB1/MYG1 Series DC12V. Metal free 2, 3 port solenoid valve for chemical liquid
Metal free, port solenoid valve for chemical liquid MY/MYG Series NC (normally closed) type, universal type Working fluid: water, pure water, chemical liquids Port size: M JIS symbol MY ( port) : NC (normally
More information5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles
ort Solenoid Valve: ase Mounted Metal Seal/Rubber Seal Series Space and capacity saving ilot valve is gathered at one side. Space saving design which does not have any protrusions. Space saving Capacity
More informationSS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring
Type4 SY000/000 ase Mounted Monifold Stacking Type/DIN ail Mounted Individual Wiring How to Order Manifold SSY 4 0 U C6 How to Order Valve Manifold ssembly Ordering example SY000 SY000 Valve stations 02
More informationPilot Operated 2 Port Solenoid Valve
CT.EUS0-9 -UK Pilot Operated Port Solenoid Valve For Water, Oil, ir Reduction of power consumption (DC specification) 6 W.5 W/5.5 W (VXD0 to 50) W W (VXD0).5 W 0.5 W ew VX D D D Series VXD// Solenoid valves
More information2.26 S OLENOID VALVES S ERIES VQ1000
2.26 S OLENOID VALVES 5 PORT M ETAL S EAL/RUBBER S EAL U LTRA H IGH S PEED S OLENOID VALVE High Speed Response from new Solenoid Design. Long Life: Over 200 Million Cycles can be with Patent Pilot Valve
More informationD-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector
Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),
More informationHigh Pressure, High Flow Rate Modular Valves
eatures Installation and mounting space can be minimized. No special skill is required for assembly and any addition or alternation of the hydraulic circuit can be made quickly and easily. roblems such
More informationHow to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa
oolant Valve Series S External pilot solenoid S ir operated S How to Order 0 0 Y 0 0 T Z q w e r t y u i o!0!!!!! q Series S00 S00 S00 w Valve type ormally closed ormally open e Seal material R FKM r Pressure
More informationDirectional Control Valves. General Description. Operation. Features
echnical Information Series D61VW General Series D61VW directional control valves are 5-chamber, pilot operated, solenoid controlled valves, hey are available in 2 or 3-position styles. hese valves are
More information4-Way, 5-Port, 2 & 3-Position Solenoid and Remote Pilot 1/2" & 3/4" Ports. Technical & Service Data. Pneumatic
atalog VL-UTO-/US (Revised 6/0/0) pplication & Model Selection S utomotive Subbase Valves -Way, -ort, & -osition Solenoid and Remote ilot /" & /" orts pplication ual pressure or diverter valve operation
More informationCoolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations
Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) type (3 to ) Low water hammer or details, refer to page 07. Large
More information;;;;;; ;;;; Bag ;; Suction pad lastic sheet Mold ;;; ;;; ;;; ;;; Heater roduct Liquid Bottle Output signal Vacuum switch Face up ; ; ;; ;; ; Sensor No
OUND-TYE VCUUM VLVES INDEX FETUES 495 INFOMTION 497 SOLENOID VCUUM VLVES DIECT CTING TYE Specifications Solenoid Vacuum Valve Order Codes Manifold Order Codes 498 Operating rinciples Symbols 499 Dimensional
More informationHow to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications
For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector
More information3-Position Rotary Table
3-osition Rotary Table Series :,,, Stop position adjustment range From center: ± Rotation range: The desired position is adjustable to between 0 and 95 from the centered position to both the right and
More informationHow to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.
Series -S00 ompact Direct Operated Port Solenoid Valve ontrol Valves ase mounted ody ported lean Series lean Series V S R oil voltage 24 VD VD VD VD VD Power consumption Pressure specification Flow rate
More informationDirectional Control Valves. General Description. Operation. Features
echnical Information Series D101VW General Series D101VW directional control valves are 5-chamber, pilot operated, solenoid controlled valves. hey are available in 2 or 3-position styles. hese valves are
More information5 Port Solenoid Valve
Metal seal Port Solenoid Valve Rubber Seal Series VQ Space-saving profile Clean space-saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less
More informationHigh Pressure Coolant Valve
High Pressure Coolant Valve Series.5 MPa, 7.0 MPa Corresponding to high speed grinding and long drilling processes Coolant valve for high pressure coolant liquid (up to.5 MPa or 7.0 MPa) that is ideal
More information