Series VXR21/22/23. Water Hammer Relief, Pilot Operated 2 Port Solenoid Valve. For Water and Oil

Size: px
Start display at page:

Download "Series VXR21/22/23. Water Hammer Relief, Pilot Operated 2 Port Solenoid Valve. For Water and Oil"

Transcription

1 Water Hammer Relief, Pilot Operated Port Solenoid Valve Series VXR//3 For Water and Oil N.C. Variations Normally closed (N.C.) Normally open (N.O.) Option Option Body Seal N.O. BC6, Valve OUT IN OUT IN Rated voltage V, V 48 V, V, V, 4 V 4 V V Material Water hammer is alleviated. Easy to disassemble and reassemble in a short time. Grommet Conduit IN terminal Conduit terminal VXR5 VXR6 VXR7 VXR38 VXR39 Port size Rc Orifice dia. (mmø), VX VX VXZ VXE VXP VXR VXH VXF VX3 VXA VCH VW VQ LVM VCA VCB VCL VCS VCW 57

2 Applicable Fluids Check List Water Hammer Relief/Pilot Operated Port Solenoid Valve Series VXR//3 Normally Closed (N.C.) Refer to page 59 for specifications and models. Option Symbol and Composition Option symbol A Seal material Coil insulation type B H Body, Shading coil material BC6, Copper Fluid Name and Option Fluid (Application) Option symbol Heated water (up to 8 C) Fuel oil (up to 6 C) A Fuel oil (up to 8 C) lf using for other fluids, please contact SMC. Normally Open (N.O.) Refer to page 6 for specifications and models. Option Symbol and Composition Option symbol A Seal material Coil insulation type B H Body, Shading coil material BC6, Copper Holder material (in core assembly) Polyacetal Stainless Steel Fluid Name and Option Fluid (Application) Heated water (up to 8 C) Fuel oil (up to 6 C) Fuel oil (up to 8 C) lf using for other fluids, please contact SMC. Option symbol A 58

3 Water Hammer Relief, Pilot Operated Port Solenoid Valve Series VXR//3 For Water and Oil Normally Closed (N.C.) JIS Symbol OUT IN Be sure to read Specific Product Precautions. Fluid specifications Water (, up to 6 C) Turbine oil Note) Refer to page 58 "Applicable Fluids Check List" for details of special fluids outside of the standard options and specifications. /Valve Specifications <Normally Closed> Connection Thread Orifice diameter (mmø) VXR5-4 VXR5-6 VXR6- VXR7- VXR38-4 VXR39- Solenoid Specifications VXR VXR VXR3 Min.operating pressure differential (MPa) Fluid and Ambient Temperature Temperature conditions Maximum Minimum High temperature water High temperature oil Max. operating pressure differential (MPa) Water Oil Option Flow characteristics Water, Oil Av x -6 (m ) Cv converted Max. system pressure (MPa) Mass (g) Note) Mass of grommet type. Add g for conduit type, 3 g for IN terminal 6 g for conduit terminal type respectively. Refer to Glossary of Terms on page 6 for details of max. operating pressure differential min. operating pressure differential and max. system pressure. Power source Frequency Apparent power (VA) (Hz) Inrush Holding Power consumption W (Holding) Temperature rise ( C ) (Rated voltage) Note) They are values in an ambient temperature of C ±5 C and application of rated voltage. Changing a coil from to is possible, but it's impossible to change from to. (Hum sound may generate because of no shading coil for.) Return voltage is % or more of the rated value at power and % or more at the power. Allowable voltage fluctuation is ±% of the rated voltage. Power source / Water () 6 4 Fluid temperature ( C) High temperature High temperature water Note ) oil Note ) Note ) Oil () Note ) 5 mm /s or less Note ) in parentheses is an option symbol. Note) Ambient temperature ( C) VX VX VXZ VXE VXP VXR VXH VXF VX3 VXA VCH VW VQ LVM VCA VCB VCL VCS VCW 59

4 Series VXR//3 How to Order (Normally Closed) Solenoid valve option Nil VXR VXR VXR3 Body size 5 A 6 5A 7 3A 8 4A 9 5A Valve/Body Normally closed/single unit Select an option mark in page 58 by "Applicable Fluids Check List" for special fluids outside of the standard. Port size Refer to the table () given below for availability. Nil T F N Rc NPTF G NPT Electrical option Nil None S With surge voltage suppressor L With indicator light Z With light/surge voltage suppressor Refer to the table () given below for availability. G Grommet C Conduit IN terminal T Conduit terminal Refer to the table () given below for availability. Rated voltage V 5/6 Hz V 5/6 Hz 3 V 5/6 Hz 4 V 5/6 Hz 5 4 V 6 V 7 4 V 5/6 Hz 8 48 V 5/6 Hz 9 Other (Please contact SMC separately.) Refer to the table () given below for availability. Refer to page 66 for ordering coil only. Thread type Table() Connection Size and Applicable Size Applicable model VXR5-4 VXR5-6 VXR6- VXR7- VXR38-4 VXR39- Ordering example (Example) Series VXR, Rc 3/4, 4 V, Conduit terminal (Part no.) VXR5-6-5T Table() Rated Voltage-Electrical Entry-Electrical Option Insulation type Electrical option ( V) ( V) 3 ( V) 4 ( V) 7 (4 V) 8 (48 V) 5 (4 V) 6 ( V) G S Note) Class B Class H C, T G, C T S L, Z S L, Z Note) Surge voltage suppressor is attached in the middle of lead wire. 6 Made to Order Made to Order Specifications Based on JIS C 9 Splashproof Specifications ( Based on IEC59IP-X4 ) VXR Port size - X36 IN terminal or class H coil not available.

5 Water Hammer Relief, Pilot Operated Port Solenoid Valve Series VXR//3 For Water and Oil Normally Open (N.O.) JIS Symbol OUT IN Be sure to read Specific Product Precautions. Fluid specifications Option Note) Water (, up to 6 C) High temperature water Turbine oil High temperature oil Note) Refer to page 58 "Applicable Fluids Check List" for details of special fluids outside of the standard options and specifications. The armature in standard products is coated in grease. /Valve Specifications <Normally Open> Connection Thread Orifice diameter (mmø) VXR5-4 VXR5-6 VXR6- VXR7- VXR38-4 VXR39- Solenoid Specifications VXR VXR VXR3 Min. operating pressure differential (MPa) Water Fluid and Ambient Temperature Temperature conditions Maximum Minimum Max. operating pressure differential (MPa) Oil Flow characteristics Water, Oil Cv Av x -6 m converted Max. system pressure (MPa) Mass (g) Note) Mass of grommet type. Add g for conduit type, 3 g for IN terminal type, 6 g for conduit terminal type respectively. Refer to Glossary of Terms on page 6 for details of max. operating pressure differential and min. operating pressure differential and max. system pressure. Power source Power source / Frequency Apparent power (VA) (Hz) Inrush Holding Water () 6 4 Fluid temperature ( C ) Oil () Note ) 5 mm /s or less Note ) in parentheses is an option symbol. Power consumption Temperature rise ( C ) (W) (Holding) (Rated voltage) Note) They are values in an ambient temperature of C ± 5 C and application of rated voltage. Changing coils from to and vice versa is impossible. because of different core shapes. Return voltage is % or more of the rated value at power and 5% or more at the power. Allowable voltage fluctuation is ±% of the rated voltage. High temperature water Note ) High temperature oil Note ) Ambient temperature ( C ) Note ) Note) VX VX VXZ VXE VXP VXR VXH VXF VX3 VXA VCH VW VQ LVM VCA VCB VCL VCS VCW 6

6 Series VXR//3 How to Order (Normally Open) VXR VXR VXR3 Electrical option Nil S L Z None With surge voltage suppressor With indicator light With light/surge voltage suppressor Refer to the table () given below for availability. Solenoid valve option Nil Body size 5 A 6 5A 7 3A 8 4A 9 5A Valve/Body Normally open/single unit Select an option mark in page 58 by "Applicable Fluids Check List" for special fluids outside of the standard. Port size Refer to the table () given below for availability. Nil T F N Rated voltage V 5/6 Hz V 5/6 Hz 3 V 5/6 Hz 4 V 5/6 Hz 5 4 V 6 V 7 4 V 5/6 Hz 8 48 V 5/6 Hz 9 Other (Please contact SMC separately) Refer to the table () given below for availability. Refer to page 66 for ordering coil only. Thread type Rc NPTF G NPT G Grommet C Conduit IN terminal T Conduit terminal Refer to the table () given below for availability. Table () Connection Size and Applicable Size Applicable model VXR5-4 VXR5-6 VXR6- VXR7- VXR38-4 VXR39- Ordering example (Example) Series VXR, Rc /4, V, Conduit terminal (Part no.) VXR7--G Table () Rated Voltage-Electrical Entry-Electrical Option Insulation type Electrical option ( V) ( V) 3 ( V) 4 ( V) 7 (4 V) 8 (48 V) 5 (4 V) 6 ( V) G S Note) Class B Class H C, T G, C T S L, Z S L, Z Note) Surge voltage suppressor is attached in the middle of lead wire. 6 Made to Order Made to Order Specifications Based on JIS C 9 Splashproof Specifications ( Based on IEC59IP-X4 ) VXR Port size - X36 IN terminal or class H coil not available.

7 Water Hammer Relief, Pilot Operated Port Solenoid Valve Series VXR//3 For Water and Oil Construction/Principal Parts Material Normally Closed (N.C.) Normally Open (N.O.) Operation < Valve opened > When the coil o is energized the armature assembly u is attracted into the core of the core assembly y and the pilot valve A opens. Then the pressure in the pressure action chamber B falls to open the main valve C. < Valve closed > When the coil o is not energized, the pilot valve A is closed and the pressure in the pressure action chamber B rises and the main valve C closes. Water hammer relieving Check valve mechanism is provided in the E side of the supply orifice and E and supply into the pressure action chamber B can be controlled with two stages by moving the diaphragm assembly r. After release of the energy, when the open amount of the main valve C becomes small, E is blocked. A low valve closing speed relieves the water hammer. No. escription Material Option 3 Body Bonnet O-ring BC6 BC6 4 iaphragm Stainless steel, Brass Stainless steel, Brass assembly 5 Valve spring Stainless steel 6 Core assembly Stainless steel, Copper 7 Armature assembly Stainless steel, Stainless steel, 8 Return spring Stainless steel 9 Coil assembly Class B molded Class H molded Operation < Valve closed > When the coil u is energized the opened pilot A closes, the pressure in the pressure action chamber B rises and the main valve C closes. < Valve opened > When the coil u is not energized, the closed pilot valve A opens, the pressure in the pressure action chamber B drops and the main valve C opens. Water hammer relieving Check valve mechanism is provided in the E side of the supply orifice and E and supply into the pressure action chamber B can be controlled with two stages by moving the diaphragm assembly r. After release of the energizing, when the open amount of the main valve C becomes small, E is blocked. A low valve closing speed relieves the water hammer. No escription Body Bonnet O-ring iaphragm assembly Valve spring 6 Core assembly BC6 BC6 Stainless steel, Brass Material Stainless steel Stainless steel, Copper,, Polyacetal, PTFE Option Stainless steel, Brass Stainless steel, Copper, PTFE 7 Coil assembly Class B molded Class H molded VX VX VXZ VXE VXP VXR VXH VXF VX3 VXA VCH VW VQ LVM VCA VCB VCL VCS VCW 63

8 Series VXR//3 Water Hammer Relieving Characteristics (VXR5/5/6/6) Water hammer (Example) Series VXR prevents damage of piping, equipment and system and generation of vibration through a great relieving of a water hammer generated using an ordinary solenoid valve. Water hammer max. pressure (MPa). MPa Po=.3 MPa Mpa Initial pressure (Pressure at valve closing) How to read the graph When the SGP piping having the same bore as the solenoid valve is 3 m in length, the maximum pressure at the initial pressure of.5 MPa results in about. MPa. (General purpose solenoid valve is 4. to 7. MPa.) SGP piping length L (m) Water Hammer Relieving Characteristics (VXR7/7/38/38/39/39) Water hammer max. pressure (MPa).8 MPa Po=.3 Mpa MPa Initial pressure (Pressure at valve closing) How to read the graph When the SGP piping having the same bore as the solenoid valve is 3 m. in the length, the maximum pressure at the initial pressure of.5 MPa results in about.8 MPa. (General purpose solenoid valve is. to 4. MPa.) SGP piping length L (m) 64

9 Water Hammer Relief, Pilot Operated Port Solenoid Valve Series VXR//3 For Water and Oil imensions Normally closed: VXR//3 Normally open: VXR//3 Grommet: G Conduit: C Conduit terminal: T IN terminal: Cable ø6 to ø x P Port size VX VX VXZ VXE VXP VXR VXH VXF VX3 VXA VCH VW VQ LVM VCA VCB VCL VCS VCW Normally closed VXR5-6 4 VXR6- VXR7- Port size P Normally open Rc 6 VXR5-4, 3 4 VXR6- VXR7-4 VXR38-4 VXR39- VXR38-4 VXR39- ( ): N.O. A B C () 8 9 (36) 6 (43) (57) (68) E F H J K L Grommet M N 74 (8) 3 88 (98) () 5.5 Conduit IN terminal N M N Q (74) (9) (9) 6 48 M 67 (74) 8 (9) 8 (9) Conduit terminal M N Q 67 (74) (9) (9) () 8 93 (3) (3) (3) (6) 8 98 (8) (8) (8)

10 Series VXR//3 Solenoid Coil Assembly How to Order Solenoid Coil Assembly VX C B VX solenoid coil assembly Size part number No. solenoid No. solenoid 3 No.3 solenoid Ordering example Application Applicable series Series VXR Series VXR Series VXR3 G Grommet C Conduit IN terminal Electrical option Nil S L Z None With surge voltage suppressor With indicator light With light/surge voltage suppressor Terminal box Nil None T With terminal box Coil insulation type B H Class B insulation Class H insulation IN terminal or not available (Example) Series VXR, V, class B insulation, grommet (Part no.) VX-GB- (Example) Series VXR, V, class B insulation, IN terminal (with terminal box) (Part no.) VX-BT-4 (Example) Series VXR3, 4 V, conduit terminal, with light/surge voltage suppressor (Part no.) VX-3CBTZ-5 Rated voltage Note) V 5/6 Hz V 5/6 Hz V 5/6 Hz V 5/6 Hz 4 V V 4 V 5/6 Hz 48 V 5/6 Hz 4 V 5/6 Hz 44 V 5/6 Hz 6 V 48 V V V Note) Voltage symbols to 8 are the same as the solenoid valve model identification symbols if the leading zero is removed. Coil Combination Table ( - Coil insulation type - Electrical option) With electrical option Without electrical option With surge With indicator With light/surge voltage suppressor light voltage suppressor Grommet GB GBS GH CB Conduit CH CBT CBTS CBTL CBTZ CHT CHTS CHTL CHTZ IN terminal B BT BTS BTL BTZ Applicable voltages for with indicator light or with light/surge voltage suppressor are V, V, V, V and 4 V. Applicable voltages for CHTL or CHTZ are V, V, V and V. Made to Order Made to Order specifications Based on JIS-C-9 Splashproof Specifications ( Based on IEC59-X4 ) Sonlenoid coil assembly model with -X36 added at the end. 66

VXP21/22/23 Series. Pilot Operated 2 Port Solenoid Valve. For Air, Gas, Steam, Water and Oil VX2 VXK VXD VXZ VXS VXB VXE VXP VXR VXH VXF VX3 VXA

VXP21/22/23 Series. Pilot Operated 2 Port Solenoid Valve. For Air, Gas, Steam, Water and Oil VX2 VXK VXD VXZ VXS VXB VXE VXP VXR VXH VXF VX3 VXA Pilot Operated Port Solenoid Valve VXP//3 Series For ir, as,, Water and Oil Variations.O..C. Wide variations of combination. ble to control a wide variety of fluids. Valve can be matched to particular

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion

More information

2/3 Port Valve for Various Fluids Control

2/3 Port Valve for Various Fluids Control Equipment for Fluid Control 2/ Port Valve for Various Fluids Control 2/ Port Solenoid/ir Operaed Valve for Various Fluids Control (For Water/ir/Oil/Gas/Vacuum/Steam) 2/ Port Solenoid Valve Direct operated

More information

2 Port Solenoid Valve For Dust Collector

2 Port Solenoid Valve For Dust Collector The VX* series will be revised shortly. 2 Port Solenoid Valve For Dust Collector Series 2 port solenoid valve for dust collector Series In this L-shaped 2 port valve, the bag filter is cleaned by high

More information

Coolant Valve. Air Operated/External Pilot Solenoid

Coolant Valve. Air Operated/External Pilot Solenoid Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) lange type (3 to ) Low water hammer or details, refer to page

More information

1.0 cm 3 /min. Pilot Operated 2-Port Solenoid Valve/ Zero Pressure Differential Operation Series VXS22/23. Compact and Lightweight mm.

1.0 cm 3 /min. Pilot Operated 2-Port Solenoid Valve/ Zero Pressure Differential Operation Series VXS22/23. Compact and Lightweight mm. Pilot Operated -Port Solenoid Valve/ Zero Pressure Differential Operation Series VXS/ Compact and Lightweight Enclosure: IP65 Low-noise construction Operation noise is reduced due to full wave rectifier

More information

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) type (3 to ) Low water hammer or details, refer to page 07. Large

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

VX Z. Zero Differential Pressure Type Pilot Operated 2 Port Solenoid Valve VXZ22/23. For Air, Water, Oil. New. Series

VX Z. Zero Differential Pressure Type Pilot Operated 2 Port Solenoid Valve VXZ22/23. For Air, Water, Oil. New. Series Zero Differential Pressure Type Pilot Operated Port Solenoid Valve For Air, Water, Oil Reduced power consumption ( spec.) VXZ: 8 W 7 W VXZ:.5 W.5 W New VX Z Z Series VXZ/ CAT.ES7-A Solenoid valves for

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Series 000 Compact and lightweight: 3 mm width Compact yet provides

More information

Process Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control Process Valve: Port Valve For Compressed ir and ir-hydro Circuit Control Series VN Style VN -6 VN -8 8 VN - 3 8 VN - 5 VN -5 VN3-0 3 0 Note) This product cannot be used for water application. JIS Symbol

More information

Compact Proportional Solenoid Valve

Compact Proportional Solenoid Valve Compact Proportional Solenoid Valve Series Repeatability: % or less Hysteresis:1% or less Fluid Flow rate control range Note) Series Air, Inert gas to L/min to L/min Note) Varies depending on the model.

More information

Direct Operated 2 Port Solenoid Valve For Water, Oil, Steam, Air

Direct Operated 2 Port Solenoid Valve For Water, Oil, Steam, Air CAT.ES0- A Direct Operated Port Solenoid Valve For Water, Oil, Steam, Air New Series VX// Reduction of power consumption ( specification) W. W W W. W 0. W Low power consumption type: 0. W (Held at V) New

More information

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control Process Valve Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external pilot

More information

Exclusively for air pressure system and air-hydro circuit control

Exclusively for air pressure system and air-hydro circuit control Process Valve Series Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external

More information

Pilot Operated/Zero Pressure Differential Operation

Pilot Operated/Zero Pressure Differential Operation ilot Operated/Zero ressure ifferential Operation 2 ort Solenoid Valve Series Z Change of valve style from.c. to.o. is simple. xcellent maintainability Separation of movable iron core and diaphragm valve

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR2 JIS Symbol type

More information

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot 3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in

More information

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control Process Series Port For Compressed Air and Air-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Cylinder actuation by external air he balance poppet

More information

Series VVXA21/22. Direct Air Operated 2 Port Valve/Manifold For Air, Gas, Vacuum and Oil VC VDW VQ VX2 VX VX3 VXA VN LVC LVA LVH LVD LVQ LQ LVN PA PAX

Series VVXA21/22. Direct Air Operated 2 Port Valve/Manifold For Air, Gas, Vacuum and Oil VC VDW VQ VX2 VX VX3 VXA VN LVC LVA LVH LVD LVQ LQ LVN PA PAX The VX series will be revised shortly. 1 Direct Operated 2 Port Valve/ For, Gas, Vacuum and Oil Series VVXA21/22 Common SUP type and individual SUP type (for vacuum use) standard models Compatible with

More information

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04 Three functions (pressure regulator, switching valve, and speed controller) are provided by a single valve. The conventional valve combination circuit has been condensed into a single valve. A large capacity

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

Direct Air Operated 2 Port Valve/Manifold For Air, Gas, Vacuum and Oil

Direct Air Operated 2 Port Valve/Manifold For Air, Gas, Vacuum and Oil The VX series will be revised shortly. 1 Direct Operated 2 Port Valve/ For, Gas, Vacuum and Oil Series VVXA21/22 Common SUP type and individual SUP type (for vacuum use) standard models Compatible with

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

Direct Operated 3 Port Solenoid Valve

Direct Operated 3 Port Solenoid Valve CT.EUS06 UK Direct Operated Port Solenoid Valve For Water, Oil, Steam, ir Reduction of power consumption (DC specification) 6 W.5 W 8 W W.5 W W New VX Series VX// Improvement of corrosion resistance Special

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position

More information

Coolant Valve. VNC Series. Cylinder actuation by pilot air

Coolant Valve. VNC Series. Cylinder actuation by pilot air oolant VN Series ir Operated/xternal Pilot Solenoid [Option] ylinder actuation by pilot air Wide selection of port and variations Threaded type (6 to ) lange type (3 to 80) Low water hammer or details,

More information

Process Valve/Series VN

Process Valve/Series VN For General Purpose /3 Port Valve Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero. Wide variations Series VNA For controlling pneumatic

More information

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S. High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure of 0.5MPa, subject to clean, dry air) 4 Port Direct

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model 2 position 3 position

More information

Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero.

Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero. For General Purpose /3 Port Valve Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero. Wide variations Series For controlling pneumatic

More information

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm 4 Port Direct Operated Poppet Solenoid Valve Series D1000 High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

High Pressure Coolant Valve

High Pressure Coolant Valve High Pressure Coolant Valve Series.5 MPa, 7.0 MPa Corresponding to high speed grinding and long drilling processes Coolant valve for high pressure coolant liquid (up to.5 MPa or 7.0 MPa) that is ideal

More information

2/3 Port Valve. Fluid Control. Solenoid Valve/Air Operated Valve For Water, Air, Oil, Gas, Vacuum and Steam

2/3 Port Valve. Fluid Control. Solenoid Valve/Air Operated Valve For Water, Air, Oil, Gas, Vacuum and Steam Fluid Control / Port Valve Solenoid Valve/ir Operated Valve For Water, ir, Oil, Gas, Vacuum and Steam Port, Direct Operated Series // N.C., N.O./Single Unit/Manifold Port, Pilot Operated (Diaphragm style)

More information

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air Compact Direct Operated / Port Solenoid Valve for Water and Air 0/0/0: Port, 00/00: Port 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to

More information

Rubber Seal VP300/500/700

Rubber Seal VP300/500/700 Port Pilot Operated Poppet Rubber Seal 00/500/700 High flow capacity Cv1.0 (00), Cv. (500), Cv.0 (700) Low power consumption: 1.8W(DC) Possible to use as either selector valve or divider valve Changeable

More information

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

Proper selection of body and sealing materials permits application of a wide variety of fluids.

Proper selection of body and sealing materials permits application of a wide variety of fluids. Direct Operated Port Valve Series A1/2 For Gas Vacuum Water and Oil Variations Proper selection of body and sealing materials permits application of a wide variety of fluids. Application can be matched

More information

Discrete direct acting 2 port solenoid valve (general purpose valve) AB31 AB41 Series NC (normally closed) type AB42 Series NO (normally open) type

Discrete direct acting 2 port solenoid valve (general purpose valve) AB31 AB41 Series NC (normally closed) type AB42 Series NO (normally open) type 31414 Series iscrete direct acting port solenoid valve (general purpose valve) 31 41 Series NC (normally closed) type 4 Series NO (normally open) type Port size: Rc1/8 to Rc1/ JIS symbol Common specifications

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series 1 Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3

More information

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000) 5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust

More information

Zero Differential Pressure Type Pilot Operated 2 Port Solenoid Valve

Zero Differential Pressure Type Pilot Operated 2 Port Solenoid Valve Zero ifferential Pressure Type Pilot Operated Port Solenoid Valve For ir, Water, Oil Reduced power consumption ( spec.) 7W VXZ:. W 0. W VXZ: 8 W New VX Z Series VXZ/ T.ES70- Solenoid valves for various

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 MPa Pilot Operated /3 Port Solenoid Valve & Check Valve VCH Series VCH4/4: Port VCH40: 3 Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve [Option] VCH40 Series Stable responsiveness Response

More information

4F0/1/2/3 Series. Min. working pressure MPa Refer to the individual specifications below to 60 Lubrication Not required (when lubricating,

4F0/1/2/3 Series. Min. working pressure MPa Refer to the individual specifications below to 60 Lubrication Not required (when lubricating, MNE0 M MN W L/ QV JIS symbol 5 port valve position single solenoid position double solenoid position all ports closed position //R connection position P// connection Common specifications Descriptions

More information

Discrete direct acting 3 port solenoid valve (general purpose valve) AG31/AG41 Series. Universal type Port size: Rc1/8, Rc1/4, Rc3/8

Discrete direct acting 3 port solenoid valve (general purpose valve) AG31/AG41 Series. Universal type Port size: Rc1/8, Rc1/4, Rc3/8 G3141 Series iscrete direct acting 3 port solenoid valve (general purpose valve) G31/G41 Series Universal type Port size: Rc1/8, Rc1/4, Rc3/8 JIS symbol G31/41: Universal type COM NO NC Common specifications

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Series SV1000/2000/3000/4000

Series SV1000/2000/3000/4000 Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double

More information

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC)

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC) Port Solenoid Valve/Direct Poppet Rubber seal Series VK3000 Nl/min 147 Compact/Width 18 X Length 8 (mm) Low power consumption 4W DC (Standard) 2W DC (Energy saver) Standard copper free specification All

More information

0.35 W (Without light)

0.35 W (Without light) Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:

More information

Pilot Operated 2-Port Solenoid Valve/ Zero Pressure Differential Operation

Pilot Operated 2-Port Solenoid Valve/ Zero Pressure Differential Operation Pilot Operated -Port Solenoid Valve/ Zero Pressure Differential Operation For Steam Compact and Lightweight New Enclosure: IP65 Low-noise construction Operation noise is reduced due to full wave rectifier

More information

1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption

1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption Port Solenoid Valve Direct Operated Poppet Type Power consumption Vacuum applications New [Option] RoHS 4 Standard wtype (Existing product: 4.8 W) 0. kpa Energy-saving type.8 w (Existing product: W) A

More information

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Body Ported Base Mounted Series S000 S000 S000 S000 S000 S4000 S5000 Sonic conductance C [dm /s bar)] 4/ 5/(A/B R/R) Single Double.8.4

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion

More information

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum 3 Port Direct Operated Poppet Rubber Seal Series 307 Large Flow Capacity, yet Compact Size. Dimensions (W X H X D) 30 X 54.5 X 33 307 Nl/min 206.02 or more, 1/4 Low Power Consumption /VO307 4.8W DC/Standard

More information

VCHR Series. Direct Operated Regulator for 6.0 MPa (Relieving Type) Service life: 10 million cycles. How to Order

VCHR Series. Direct Operated Regulator for 6.0 MPa (Relieving Type) Service life: 10 million cycles. How to Order Direct Operated Regulator for 6.0 MPa (Relieving Type) VCHR Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high pressure

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion

More information

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing

More information

4 qwer 2/2. Pilot Operated General Service Solenoid Valves. Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT. Features. Construction.

4 qwer 2/2. Pilot Operated General Service Solenoid Valves. Brass or Stainless Steel Bodies 3/8 to 2 1/2 NPT. Features. Construction. 4 qwer Pilot Operated General Service Solenoid Valves Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT NC NO 2/2 SERIES Features Wide range of pressure ratings, sizes, and resilient materials provide

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

NAMUR Interface 5 Port Solenoid Valve

NAMUR Interface 5 Port Solenoid Valve NAMUR Interface 5 Port Solenoid Valve Series VFN000N 5 5 Specifications Valve Electrical entry Fluid Max. operating pressure Min. operating pressure Ambient and fluid temperature Lubrication Pilot operator

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types Speed 2 Port Valve Series RoHS speed speed speed response response response 5 ms 9mm Width ±0.05 ms ±0.05 ms type VCH : : 5 ms * The response time is measured based on SMC test conditions. (Not guaranteed

More information

Discrete direct acting 3 port solenoid valve (general purpose valve) Universal type Port size: Rc1/8, Rc1/4, Rc3/ to to 60 B

Discrete direct acting 3 port solenoid valve (general purpose valve) Universal type Port size: Rc1/8, Rc1/4, Rc3/ to to 60 B G31/41 Series iscrete direct acting 3 port solenoid valve (general purpose valve) G31/41 Series Universal type Port size: Rc1/8, Rc1/4, Rc3/8 Refer to nding 17 for more details. JIS symbol G31/41: Universal

More information

Pilot Operated 2-Port Solenoid Valve/ Zero Pressure Differential Operation

Pilot Operated 2-Port Solenoid Valve/ Zero Pressure Differential Operation Pilot Operated 2-Port Solenoid Valve/ Zero Pressure Differential Operation For Steam Compact and Lightweight New Enclosure: IP65 Low-noise construction Operation noise is reduced due to full wave rectifier

More information

Flow characteristics Max. (1) b Standard Specifications. P Manual override.

Flow characteristics Max. (1) b Standard Specifications. P Manual override. Port Direct Operated Solenoid Valve Series 0 Metal Seal Model Number of positions (Single) (Double) ( position) JIS Symbol Model Port size Rc (Nominal size) 0-0 8 ( A) 0- ( 8A) 0-0 8 (0A) 0-0 8 ( A) 0-

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

Series AV2000/3000/4000/5000

Series AV2000/3000/4000/5000 Soft Start-up Valve Series AV/3/4/5 Series introduced! A start-up valve that gradually increases supply pressure during start up and rapidly exhausts system air when the supply air is shut off AC AV AU

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position

More information

/2. Hot Water and Steam Valves Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT ^ % )

/2. Hot Water and Steam Valves Brass or Stainless Steel Bodies 1/8 to 2 1/2 NPT ^ % ) 888-87-6711 Normally Closed or Normally Open ot Water and Valves Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT Features ot water service to 210 psi differential @ 210 F; sevice to 125 psi differential

More information

3 Way/2 Position Valves

3 Way/2 Position Valves Way/ Position Valves Three way valves have three pipe connections and two orifices. When one orifice is open, the other is closed, and vice versa. They are commonly used to alternately apply pressure to

More information

Pilot Operated 2 Port Solenoid Valve

Pilot Operated 2 Port Solenoid Valve CT.EUS0-9 -UK Pilot Operated Port Solenoid Valve For Water, Oil, ir Reduction of power consumption (DC specification) 6 W.5 W/5.5 W (VXD0 to 50) W W (VXD0).5 W 0.5 W ew VX D D D Series VXD// Solenoid valves

More information

2/2 ^ % ) Normally Closed or Normally Open Hot Water and Steam Valves. Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT

2/2 ^ % ) Normally Closed or Normally Open Hot Water and Steam Valves. Brass or Stainless Steel Bodies 1/8 to 2 1/2 NPT Normally Closed or Normally Open Hot Water and Valves Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT 2/2 Features Handle the challenges of high-temperature fluids PTFE and EPDM discs, stainless steel

More information

5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type. Closed Center DS3330/DS3300. How to Order - Body Ported Type

5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type. Closed Center DS3330/DS3300. How to Order - Body Ported Type 5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type COMPACT SIZE AND LIGHT WEIGHT LARGE FLOW CAPACITY LOW POWER CONSUMPTION DESIGNED FOR NON-LUBRICATED SERVICE DV000 Symbol Single DS330/ How

More information

3 Port Air Operated Valve VTA. Indicate VO for manifold. Port size. Nil 02 1/4. Specifications Fluid. Option Description Bracket (With screw)

3 Port Air Operated Valve VTA. Indicate VO for manifold. Port size. Nil 02 1/4. Specifications Fluid. Option Description Bracket (With screw) Series VTA301 How to Order VTA 301 Indicate VO for manifold. Port size Without connection port (For manifold) 01 1/8 02 1/4 F N T Option B Rc G NPT NPTF Without bracket Foot bracket JIS Symbol Specifications

More information

General purpose direct acting 2, 3 port solenoid valve

General purpose direct acting 2, 3 port solenoid valve eneral purpose direct acting, 3 port solenoid valve (eneral purpose valve) eneral purpose Direct acting, 3 port solenoid valve / Pilot operated/pilot kick type port solenoid valve P/D/PK/DK Page 9 9 P/

More information

Series VCHR. Direct Operated Regulator for 6.0 MPa (Relieving Type) Service life: 10 million cycles. How to Order

Series VCHR. Direct Operated Regulator for 6.0 MPa (Relieving Type) Service life: 10 million cycles. How to Order Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane

More information

1 1/4 (32A) to 2 (50A) added.

1 1/4 (32A) to 2 (50A) added. Coolant Valve 0.5 MPa.0 MPa.6 MPa RoHS /4 (3) to (50) added. Flow rate Cv (For 0.5 MPa specification) 3 4 5 0 0 30 Cv (kv) 40 5 million cycles or more Port size 70 6.5 (5.6) 3/8 (0), / (5).8 (0.) 3/4 (0)

More information

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

More information

4 qwer. Steam and Hot Water Valves 2/2 SERIES. Hot Water/ Steam. Features. Construction. Nominal Ambient Temperature Ranges: Electrical.

4 qwer. Steam and Hot Water Valves 2/2 SERIES. Hot Water/ Steam. Features. Construction. Nominal Ambient Temperature Ranges: Electrical. qwer Normally Closed or Normally Open and Hot Water Valves Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT NC NO 2/2 SERIES Features Handle the challenges of high-temperature fluids. PTFE and EPDM discs,

More information

Indicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A

Indicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A 1 3 Port Air Operated Valve Series VTA301 JIS Symbol VTA 301 Indicate VO for manifold. Port size Specifications How to Order Without connection port (For manifold) 01 1/8 02 1/4 Option Fluid Air Operating

More information