Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air
|
|
- Amber Gwenda Carson
- 5 years ago
- Views:
Transcription
1 Compact Direct Operated / Port Solenoid Valve for Water and Air 0/0/0: Port, 00/00: Port 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to pages 7 for 0/0 and 7 ( VX) for 0, respectively. VCH Molded coil specifications have been added! IP rommet/molded Flat terminal/molded 89 A
2 For Water and Air Compact Direct Operated / Port Solenoid Valve 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to pages 7 for 0/0 and 7 ( VX) for 0, respectively. Improved durability (Nearly twice the life of the previous series) The use of a unique magnetic material reduces the operating resistance of moving parts, while improving service life, wear and corrosion resistance. Improved corrosion resistance Special material introduced Clip type Ease of maintenance has been improved. Changing of the coil is made easy by means of clip design. ( port) Threaded assembly Simplifies maintenance. High flow rate: Cv factor 0.0 to 0. ( port) Universal porting 00/00 ( port) Brass (C7)/Stainless steel manifolds added to series ( port) Improved environment resistance Environment resistance is improved by using a molded coil. (Enclosure IP or equivalent, grommet mold) Threaded for bottom mounting Special bracket can be mounted. rommet/molded Lineup by Compact Design Port Port P.9 P.0 ø0. ø7 ø8 ø0. ø
3 Compact Direct Operated 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to pages 7 for 0/0 and 7 ( VX) for 0, respectively. Port Solenoid Valve for Water and Air 0/0/0 For Water, Air, Vacuum 0 0 Valve type 0 N.C. How to Order Valves (Single Unit) VD W 0 Voltage Voltage rommet / Flat rommet / Tape terminal, winding () Molded (F) Molded (W) V S R 00 VAC (0/0 Hz) 00 VAC (0/0 Hz) 0 VAC (0/0 Hz) 0 VAC (0/0 Hz) VDC VDC VDC VDC VDC Please consult with SMC regarding other voltages. rommet / Tape winding Coil type W rommet / Molded A B H J L Note) Thread type Rc F N NPT Q [Option] CE-compliant Made to Order (Refer to page 9.) CE-compliant Option None F Foot bracket Note) The foot bracket is packed with a valve. Material and insulation type Body Seal Coil material material insulation Brass (C7) Stainless steel Class B Note) The armature assembly is a corrosion resistant construction. VCH Magnet wire protection: Tape winding F Flat terminal / Molded Magnet wire protection: Resin Molded Port size 0 0 Port size /8 (A) / (8A) Orifice diameter Magnet wire protection: Resin Molded and Coil Type Combinations rommet / Tape winding Flat terminal / Molded rommet / Molded Orifice diameter (mm ø) A
4 0/0/0 Standard Specifications 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to pages 7 for 0/0 and 7 ( VX) for 0, respectively. Made to Order (For details, refer to page 07.) Specifications Non-leak (0 - Pa m /sec) / -X Vacuum (0.Pa abs) specification -X -X0 -X Oil-free specification Lead wire length: 00 mm specification Seal material: Perfluoroelastomer specification Valve specifications Coil specifications Valve construction Note ) Fluid Withstand pressure (MPa) Ambient temperature ( C) Fluid temperature ( C) Environment Valve leakage (cm /min) Mounting orientation Vibration/Impact (m/s ) Note ) Rated voltage Allowable voltage fluctuation (%) Coil insulation type Enclosure rommet / Tape winding Flat terminal / Molded rommet / Molded Note ) Power consumption (W) Direct operated poppet Water (except waste water or agricultural water), Air, Low vacuum.0 0 to 0 to 0 (No freezing) Location without corrosive or explosive gases 0 (with water pressure) or less (Air) Unrestricted 0/0 VDC, VDC, VDC, VDC, VDC, 00 VAC, 0 VAC, 00 VAC, 0 VAC (0/0 Hz) ±0% of rated voltage Class B Dust-proof (equivalent to IP0) Dust-tight (equivalent to IP0) Note ) Dust-tight / Low jetproof (equivalent to IP). (0), (0/0) Note ) When used under conditions which may cause condensation on the exterior of the product, select rommet / Molded. Note ) When used with deionized water, select L (Stainless steel, ) for the material type. Note ) Since the AC coil specification includes a rectifier element, there is no difference in power consumption between inrush and holding. In the case of 0/0 VAC, the 0 is W and the 0/0 is. W. Note ) Vibration resistance No malfunction when tested with one sweep of to 00 Hz in the axial direction and at a right angle to the armature, in both energized and deenergized states. Impact resistance No malfunction when tested with a drop tester in the axial direction and at a right angle to the armature, one time each in energized and deenergized states. Note ) Since electrical connections are exposed, there is no water resistance. Characteristic Specifications Model Port size /8 (A) /8 (A) / (8A) Orifice dia. (mm ø).... Max. operating pressure differential (MPa) Note ) Pressure port Operating Pressure range (MPa) Note ) 0 to.0 Weight (kg) Note ) The maximum operating pressure differential changes depending on the flow direction of the fluid. Refer to page for details. Note ) For low vacuum specifications, the operating pressure range is Torr (. x 0 Pa) to.0 MPa. Please consult with SMC if using below Torr (. x 0 Pa) /8: 0. /: 0. Flow Characteristics Model Port size /8 (A) /8 (A) / (8A) Orifice dia. (mm ø) N.C..... Av x 0 m Water Air (IN N.C.) (IN N.C.) Cv converted C [dm /(s bar)] b Cv B 9
5 Compact Direct Operated Port Solenoid Valve for Water and Air 0/0/0 Construction 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to pages 7 for 0/0 and 7 ( VX) for 0, respectively. i w e r u i w e r u t y q t y q i w VCH e r u t y q Component Parts Material No. Description Standard 7 8 Body Tube assembly Coil assembly Armature assembly O-ring (Body) Return spring Cover Clip Brass (C7) Stainless steel Stainless steel, PPS, Stainless steel SPCE Stainless steel Option Stainless steel,, 9
6 0/0/0 Dimensions 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to pages 7 for 0/0 and 7 ( VX) for 0, respectively. - W - W 0 Lead wire L Approx. 00 Lead wire L Approx x ø. 0 Rectifier element AC type ø x ø. 0 7 Rectifier element AC type ø0. (OUT) port (IN) port 8, /8 (OUT) port, /8 (IN) port x M. x. x M x - W (7.) Lead wire L Approx SMC SMC Rectifier element AC type ø8 8. (.) Bracket assembly part no. 0, 0 0 A VCW0 0A Dimensions inside ( ) are for port size /8..8 x ø (.) /8, / (OUT) port /8, / (IN) port 9 x M x
7 Compact Direct Operated Port Solenoid Valve for Water and Air 0/0/0 Dimensions -F 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to pages 7 for 0/0 and 7 ( VX) for 0, respectively. -F x ø. (Bracket mounting hole) SMC x ø.7 M. (for grounding) M. (for grounding) *F- * - *** - * - * -*F- * - *** - * - *..8 (.) 8, /8 (OUT) port, /8 (IN) port (7.) 8. (.) /8, / (OUT) port /8, / (IN) port x M x x M x.8 VCH Bracket assembly part no. 0 0 A 0 VCW0 0A 9
8 0/0/0 How to Order Manifold [Option] A V 0 0 A B H J Material Manifold material Brass (C7) Stainless steel Seal material Blanking plate assembly 0, 0 Valve type N.C. for manifold V 0 A Stations 0 stations 0 0 stations How to Order Valves (For Manifold) V S R Manifold Options 0 0 Voltage 00 VAC (0/0 Hz) 00 VAC (0/0 Hz) 0 VAC (0/0 Hz) 0 VAC (0/0 Hz) VDC VDC VDC VDC VDC Please consult with SMC regarding other voltages. 9 Thread type F N OUT port size Port size 0 /8 (A) 0 / (8A) Rc NPT Voltage rommet / Flat rommet / Tape terminal, winding () Molded (F) Molded (W) Material H J Plate material Stainless steel Seal material Plate material is stainless steel only. A B H J L Note) 0 0 Note) IN port sizes are as follows. 0: /8 (A) 0: / (8A) 0: /8 (0A) F W F CE-compliant Q Option Coil type Note) CE-compliant None With bracket Note) 0 is available with bracket only. 0 0 VVCW0 How to Order Manifold Assembly Enter the mounting valve and option part numbers under the manifold base part number. <Ordering example> V-00 (-Q) set Manifold part no. -- (-Q) sets Valve part no. (Stations to ) D side U side Material and insulation type Body material Seal material Coil insulation Brass (C7) Class B Stainless steel rommet / Tape winding Flat terminal / Molded rommet / Molded Note) About series and coil type combinations, refer to page 9. H J is the symbol for assembly. Add an in front of the part numbers to have solenoid valves, etc. mounted on manifold. Orifice diameter A Q Enter together in order, counting from station on the D side. Orifice diameter (mmø).... Material Plate material Seal material Stainless steel CE-compliant CE-compliant Note) The armature assembly is a corrosion resistant construction
9 Compact Direct Operated Port Solenoid Valve for Water and Air 0/0/0 Dimensions V (.) R Approx (9.) 0 (.8) 8.8 x /8 (IN port) ( : Thread type) 8.8 P = 7. L L L - * - * - * - * - * - * - * - * n x (OUT port) 8. x M x 0. When w/o bracket, M threads at both ends ( locations) can be used for other purposes. (.) (.).8. D side Stations n U side VCH 7.7 P = L Dimension (mm) Dimension L L L Manifold composition stns. x.. 9. stns. x stns. x stns. + stns. stns. x n (stations) stns. x + stns. stns. + stns. x stns. x stns. x + stns. x Note) Manifold base is consisted of the junction of and station bases. Refer to pages 00 and 0 regarding manifold additions. 97
10 0/0/0 Dimensions V (9.) L L L Approx. 00. (.). 9 x / (IN port) ( : Thread type) R. D side Stations n U side -*-* -*-* -*-* -*-* P = n x x 0.8 n x /8 (OUT port).. (9.) x M When w/o bracket, M threads at both ends ( locations) can be used for other purposes. L Dimension (mm) Dimension n (stations) L L L Manifold composition stns. x stns. x stns. x stns. + stns. stns. x stns. x + stns. stns. + stns. x stns. x stns. x + stns. x Note) Manifold base is consisted of the junction of and station bases. Refer to pages 00 and 0 regarding manifold additions. 98
11 Compact Direct Operated Port Solenoid Valve for Water and Air 0/0/0 V 9 L L L R Approx. 00 (.). 8 8 (.).. 0. x /8 (IN port) ( : Thread type) VCH D side Stations n U side -*-* -*-* -*-* -*-* 7. P =. n x /8 n x / (OUT port) 7.. L Dimension Dimension L L L Manifold composition stns. x stns. x stns. x stns. + stns. stns. x Note) Manifold base is consisted of the junction of and station bases. Refer to pages 00 and 0 regarding manifold additions. n (stations) stns. x + stns. stns. + stns. x stns. x (mm) stns. x + stns. x 99
12 0/0/0 Manifold Exploded View Bracket assembly Manifold base for stations Passage pipe assembly Manifold base for stations Bracket assembly Connecting plate assembly Connecting plate assembly Figure shows V. Manifold additions Install a passage pipe assembly in between the manifold bases to be added. Connect the respective manifold bases with a connecting plate assembly. (Tightening torque: 0.9 ± 0. N m) Attach brackets to the manifold bases. {when equipped with brackets} (Tightening torque: 0.9 ± 0. N m) Note) Manifold can be increased by every or -station unit. Order one set each of manifold base, connection plate assembly and passage pipe assembly. 00
13 Compact Direct Operated Port Solenoid Valve for Water and Air 0/0/0 <Manifold base> 0, 0 V 0 C 0 C S Material Brass (C7) Stainless steel Stations For stations For stations 0 VVCW0 C 0 C S <Bracket assembly> 0, 0 V 0 0 Material Brass (C7) Stainless steel 0 0 Stations For stations For stations 0 A Thread type F N Rc NPT OUT port size 0 Thread type F N Port size /8 (A) 0 is available with only. Rc NPT OUT port size 0 0 Port size /8 (A) / (8A) Note) Consists of a set for D and U sides. <Connecting plate assembly> 0, 0 V 0 A 0 VVCW0-A <Passage pipe assembly> 0, 0 V VVCW0 0 A A Note) Two sets of connecting plate and mounting screws. Material Pipe material Seal material A B Brass (C7) Stainless H steel J Material Pipe material Seal material A B Brass (C7) Stainless H steel J VCH 0 VVCW0-A 0
14 Compact Direct Operated Port Solenoid Valve for Water and Air 00/00 For Water, Air, Vacuum 0 VD W Valve type C.O. How to Order Valves (Single Unit) 0 Made to Order (Refer to page 0.) [Option] CE-compliant Q CE-compliant Option None F Foot bracket Note) The foot bracket is packed with a valve. Voltage Voltage rommet / Flat rommet / Tape terminal, winding () Molded (F) Molded (W) V S R 00 VAC (0/0 Hz) 00 VAC (0/0 Hz) 0 VAC (0/0 Hz) 0 VAC (0/0 Hz) VDC VDC VDC VDC VDC Please consult with SMC regarding other voltages. rommet / Tape winding Coil type W rommet / Molded Thread type Rc F N NPT Material and insulation type A B H J L Note) Body material Brass (C7) Stainless steel Seal material Coil insulation Class B Note) The armature assembly is a corrosion resistant construction. B Magnet wire protection: Tape winding F Flat terminal / Molded Magnet wire protection: Resin Molded 0 Magnet wire protection: Resin Molded Port size 0 0 Port size /8 (A) / (8A) 00 Orifice diameter N.C. N.O. Orifice diameter Orifice diameter (mm ø) (mm ø)
15 Compact Direct Operated Port Solenoid Valve for Water and Air 00/00 Standard Specifications Made to Order (For details, refer to page 07.) Specifications Non-leak (0 - Pa m /sec) / -X Vacuum (0.Pa abs) specification -X -X0 -X Oil-free specification Lead wire length: 00 mm specification Seal material: Perfluoroelastomer specification Flow Characteristics Valve specifications Coil specifications Valve construction Fluid Note ) Withstand pressure (MPa) Ambient temperature ( C) Fluid temperature ( C) Environment Valve leakage (cm /min) Mounting orientation Vibration/Impact (m/s Note ) ) Rated voltage Allowable voltage fluctuation (%) Coil insulation type Enclosure rommet / Tape winding Flat terminal / Molded rommet / Molded Power consumption (W) Note ) Characteristic Specifications Direct operated poppet Water (except waste water or agricultural water), Air, Low vacuum.0 0 to 0 to 0 (No freezing) Location without corrosive or explosive gases 0 (with water pressure) (Air) Unrestricted 0/0 VDC, VDC, 00 VAC, 0 VAC, 00 VAC, 0 VAC (0/0 Hz) ±0% of rated voltage Class B Dust-proof (equivalent to IP0) Dust-tight (equivalent to IP0) Note ) Dust-tight / Low jetproof (equivalent to IP) Note ) Please consult with SMC when used under conditions which may cause condensation on the exterior of the product. Note ) When used with deionized water, select L (Stainless steel, ) for the material type. Note ) Since the AC coil specification includes a rectifier element, there is no difference in power consumption between inrush and holding.. W in the case of 0/0 VAC Note ) Vibration resistance No malfunction when tested with one sweep of to 00 Hz in the axial direction and at a right angle to the armature, in both energized and deenergized states. Impact resistance No malfunction when tested with a drop tester in the axial direction and at a right angle to the armature, one time each in energized and deenergized states. Note ) Since electrical connections are exposed, there is no water resistance. Model Port size /8 (A) /8 (A) / (8A) Orifice dia. (mm ø). Max. operating pressure differential (MPa) Note ) Pressure port Pressure port, Note ) Note ) Indicates the maximum operating pressure differential of pressure ports and. Note ) The maximum operating pressure differential changes depending on the flow direction of the fluid. Refer to page for details. Note ) For low vacuum specifications, the operating pressure range is Torr (. x 0 Pa) to.0 MPa. Please consult with SMC if using below Torr (. x 0 Pa). Operating pressure range (MPa) Note ) 0 to.0 Weight (kg) 0. /8: 0.7 /: 0.0 VCH Model 00 Port size /8 (A) Orifice dia. (mm ø) N.C.. N.O. (IN N.C.) (IN N.O.) (IN N.C.) (IN N.O.) Av x 0 m Water Cv converted Av x 0 m 0.9 Cv converted 0.0 C [dm /(s bar)] b Cv Air C [dm /(s bar)] 0. b 0. Cv /8 (A) / (8A) B
16 00/00 Construction 0 i o!0! w e r u t y q 0 i o!0! w e r u t y q Component Parts Material No. Description Body Tube assembly Coil assembly Armature assembly O-ring (Body) Return spring Cover Socket O-ring Plate Wave washer Standard Brass (C7) Stainless steel Stainless steel, PPS, Stainless steel SPCE C SPCC Stainless steel Option Stainless steel Stainless steel, PPS,,, Stainless steel, 0
17 Compact Direct Operated Port Solenoid Valve for Water and Air 00/00 Dimensions 0- W 0- W 7 0 Lead wire L Approx. 00 (7.) Lead wire L Approx. 00 x ø. 0 7 ø0., /8 (N.O.) port Rectifier element AC type 0 0 x ø SMC /8, / (N.O.) port SMC Rectifier element AC type ø (8.), /8 (N.C.) port, /8 (IN) port 8. (.) x M x /8, / (N.C.) port /8, / (IN) port Dimensions inside ( ) are for port size /8. VCH.8 x M x Bracket assembly part no A 00 VCW0 0A 0
18 00/00 Dimensions 0-F 0-F /8, / (N.O.) port 7 0, /8 (N.O.) port x ø. (Bracket mounting hole) SMC x ø M. (for grounding) 0.8 M. (for grounding) *F- * - *** - * - * 0-*F- * - *** - * - * (.) 8 (8.), /8 (N.C.) port, /8 (IN) port (7.) /8, / (N.C.) port /8, / (IN) port x M x x M x.8 Bracket assembly part no A 00 VCW0 0A 0
19 Made to Order Specifications: Please consult with SMC for detailed size, specifications and delivery. 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to pages 7 for 0/0 and 7 ( VX) for 0, respectively. Non-leak (0 Pa m /sec)/vacuum (0. Pa abs) Specification -X Standard model no. X(-Q) Oil-free Specification -X Standard model no. X(-Q) Lead Wire Length: 00 mm Specification -X0 Standard model no. X0(-Q) Seal Material: Perfluoroelastomer Specification Standard model no. X(-Q) -X VCH 07 A
20 Specific Product Precautions Be sure to read this before handling. Refer to front matter for Safety Instructions, and pages 7 to 9 for Port Solenoid Valves for Fluid Control Precautions. 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to pages 7 for 0/0 and 7 ( VX) for 0, respectively. Warning Design. Cannot be used as an emergency shutoff valve, etc. The valves presented in this catalog are not designed for safety applications such as an emergency shutoff valve. If the valves are used in this type of system, other reliable safety assurance measures should also be adopted.. Extended periods of continuous energization Please consult with SMC when using with energization for long periods of time.. Liquid rings In cases with a flowing liquid, provide a by-pass valve in the system to prevent the liquid from entering the liquid seal circuit.. This solenoid valve cannot be used for explosion proof applications.. Maintenance space The installation should allow sufficient space for maintenance activities (removal of valve, etc.). Warning Selection. Confirm the specifications. ive careful consideration to the operating conditions such as the application, fluid and environment, and use within the operating ranges specified in this catalog.. Fluid temperature Please use within the operating fluid temperature range.. Fluid quality In the case of water The use of a fluid which contains foreign matter can cause problems such as malfunction and seal failure by promoting wear of the valve seat and armature, and by sticking to the sliding parts of the armature, etc. Install a suitable filter (strainer) immediately upstream from the valve. In general, a mesh of about 80 to 00 is a guideline for the filter. In the case of air Please use ordinary compressed air where a filter of 0 µm or less is provided on the inlet side piping. (Except dry air) Caution. Leakage voltage Particularly when using a resistor in parallel with a switching element and using a C-R element (surge voltage suppressor) to protect the switching element, take note that leakage current will flow through the resistor, C-R element, etc., creating a possible danger that the valve may not turn off. Power supply Switching element OFF C R Leakage current Leakage voltage SOL. AC coil 0% or less of rated voltage DC coil % or less of rated voltage. Low temperature operation ) The valves can be used up to an ambient temperature of 0 C, however take measures to prevent solidification of impurities or freezing etc. ) When using valves for water application in cold climates, first stop the water supply/discharge of the pump etc., and then take measures to prevent freezing such as draining water in pipe. When heating by steam, be careful not to expose the coil portion to steam. Also, please take measures to prevent freezing such as heating the body. 08
21 Specific Product Precautions Be sure to read this before handling. Refer to front matter for Safety Instructions, and pages 7 to 9 for Port Solenoid Valves for Fluid Control Precautions. 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to pages 7 for 0/0 and 7 ( VX) for 0, respectively. Warning Mounting. If air leakage increases or equipment does not operate properly, stop operation. After mounting is completed, confirm that it has been done correctly by performing a suitable function test.. Do not apply external force to the coil section. When tightening is performed, apply a wrench or other tool to the outside of the piping connection parts.. Do not warm the coil assembly with a heat insulator, etc. Use tape, heaters, etc., for freeze prevention on the piping and body only. They can cause the coil to burn out.. Secure with brackets, except in the case of steel piping and copper fittings.. Avoid sources of vibration, or adjust the arm from the body to the minimum length so that resonance will not occur.. Instruction manual The product should be mounted and operated after the instruction manual is thoroughly read and its contents are understood. Keep the instruction manual where it can be referred to as needed. 7. Painting and coating Warnings or specifications printed or labeled on the product should not be erased, removed or covered up. Caution Piping. Preparation before piping Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe.. Wrapping of pipe tape When connecting pipes, fittings, etc., be sure that chips from the pipe threads and sealing material do not enter the valve. Furthermore, when pipe tape is used, leave. to thread ridges exposed at the end of the threads. Winding direction Expose approx. threads Pipe tape. Avoid connecting ground lines to piping, as this may cause electric corrosion of the system.. Always tighten threads with the proper tightening torque. When attaching fittings to valves, tighten with the proper tightening torque shown below. Tightening Torque for Piping Connection threads Proper tightening torque N m (kgf cm). to ( to 0) Rc /8 7 to 9 (70 to 90) Rc / to (0 to 0) Rc /8 to (0 to 0) Reference Tightening of fitting threads After tightening by hand, tighten approximately / turn further with a tightening tool. However, when using miniature fittings, tighten an additional / turn after tightening by hand. (In cases where there are gaskets in two places, such as a universal elbow or universal tee, double the additional tightening to / turn.) VCH. Connection of piping to products When connecting piping to a product, refer to its instruction manual to avoid mistakes regarding the supply port, etc. Do not apply external force to the coil when holding it to connect piping, as the tube may deform. 09
22 Specific Product Precautions Be sure to read this before handling. Refer to front matter for Safety Instructions, and pages 7 to 9 for Port Solenoid Valves for Fluid Control Precautions. 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to pages 7 for 0/0 and 7 ( VX) for 0, respectively. Caution Wiring. As a rule, use electrical wire with a cross sectional area of 0. to. mm for wiring. Furthermore, do not allow excessive force to be applied to the lines.. Use electrical circuits which do not generate chattering in their contacts.. Use voltage which is within ±0% of the rated voltage. In cases with a DC power supply where importance is placed on responsiveness, stay within ±% of the rated value. The voltage drop is the value in the lead wire section connecting the coil. Warning Operating Environment. Do not use the valves in an atmosphere having corrosive gases, chemicals, salt water, water, steam, or where there is direct contact with any of these.. Do not use in explosive atmospheres.. Do not use in locations subject to vibration or impact.. Do not use in locations where radiated heat will be received from nearby heat sources.. Employ suitable protective measures in locations where there is contact with water droplets, oil or welding spatter, etc. There is no polarity for DC. Lead wire: AW0, outside diameter of insulator.79 (+, ) Caution Rated voltage DC q w 00 VAC 00 VAC Other AC Caution DC circuit Electrical Connections Electrical Circuit Lead wire color Black Red Blue Blue Red Red ray ray AC circuit Varistor Rectifier element Warning Caution Maintenance. Perform maintenance according to the procedure in the instruction manual. Incorrect handling will cause damage or malfunction to devices or equipment.. Removing the product ) Shut off the fluid supply and release the fluid pressure in the system. ) Shut off the power supply. ) Dismount the product.. Low frequency operation Switch valves at least once every 0 days to prevent malfunction. Also, in order to use it under the optimum state, conduct a regular inspection once a half year.. Filters and strainers ) Be careful regarding clogging of filters and strainers. ) Replace filter elements after one year of use, or earlier if the pressure drop reaches 0. MPa. ) Clean strainers when the pressure drop reaches 0. MPa. ) Exhaust the drain from an air filter periodically.. Storage When not using for a long time (more than approx. one month) after use with water, thoroughly remove all moisture to prevent rust and deterioration of rubber materials, etc. SOL. SOL. (, +) 0
23 Specific Product Precautions Be sure to read this before handling. Refer to front matter for Safety Instructions, and pages 7 to 9 for Port Solenoid Valves for Fluid Control Precautions. 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to pages 7 for 0/0 and 7 ( VX) for 0, respectively. Caution Replacing the Solenoid Coils port valve port valve Socket Flat head screwdriver q Tube assembly Clip O-ring Plate Press the clip in direction q with a flat head screwdriver, etc., and remove it from the tube assembly groove. Wave washer Solenoid coil w Solenoid coil Remove the cover in direction w, and replace the solenoid coil. Fixed armature threads VCH Tube assembly groove e Center of clip After replacing the coil, insert the clip into the tube assembly groove from direction e. After inserting it into the groove, confirm the position and condition of the clip. After removing the socket with a wrench, etc., lift off the plate, wave washer and cover, and replace the coil assembly. After replacing the coil, first tighten the socket by hand while holding down the plate and wave washer, and then tighten it further with a torque of 0.8 to N m. Precautions when attaching and removing the socket Be careful that the O-ring installed on the bottom (plate side) of the socket does not fall out or become chewed up, etc. Be sure to secure the body by wrench, etc., and tighten the socket within the tightening torque range given above. If the torque is applied excessively, there is a danger of damaging the threads. OK N Inserted position Inserted condition
24 Specific Product Precautions Be sure to read this before handling. Refer to front matter for Safety Instructions, and pages 7 to 9 for Port Solenoid Valves for Fluid Control Precautions. 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to pages 7 for 0/0 and 7 ( VX) for 0, respectively. B Replacement Parts Solenoid coil part no. 0 C C F W 0 0, 00 0, 00 Coil type rommet / Tape winding Flat terminal / Molded rommet / Molded Type 0, 0, 0 00, 00 Lead wire length 00 mm L Note) 00 mm Voltage Note) To have a label on the cover, enter the part number below together with the coil part number. AZ-T- Clip part no. ( port) 0 0, Socket assembly part no. ( port) 0 A Port size 0 0 /8 (A) / (8A) Port size V S R Note) Type L is optional. 00 VAC 00 VAC 0 VAC 0 VAC VDC VDC VDC VDC VDC Coil Type and Voltage Combinations Voltage 00 VAC 00 VAC 0 VAC 0 VAC VDC VDC VDC VDC VDC rommet / Tape winding Flat terminal / Molded rommet / Molded Valve model no. on pages 9, 9, 0 A B H J L Thread type F N Material Socket material Seal material Brass (C7) Stainless steel Rc NPT Piping to Port Valve N.O. Port Caution Socket Cover When piping to an N.O. port, be sure to perform piping work while securing the socket by using wrench or other tool. Refer to back page 09 for other precautions related to piping. Fluid Flow Direction Caution The maximum operating pressure differential differs depending on the flow direction of the fluid. If the pressure differential at each port exceeds the values in the table below, valve leakage may occur. Port Valve Model Orifice diameter (mm ø) Max. operating pressure differential (MPa) Pressure port Pressure port Note) Note) When applying pressure from port, be careful to avoid vibration and impacts, etc. Port Valve Model Orifice diameter (mm ø) Max. operating pressure differential (MPa) Pressure port Pressure port, Note ) Note ) Indicates the maximum operating pressure differential of pressure ports and. Note ) When the port pressure is in the higher pressure side, be careful to avoid vibration and impacts, etc.
25 Specific Product Precautions Be sure to read this before handling. Refer to front matter for Safety Instructions, and pages 7 to 9 for Port Solenoid Valves for Fluid Control Precautions. lossary 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to pages 7 for 0/0 and 7 ( VX) for 0, respectively. Pressure Terminology. Maximum operating pressure differential This indicates the maximum pressure differential (inlet and outlet pressure differential) which can be allowed for operation with the valve closed or open. When the outlet pressure is 0 MPa, this becomes the maximum operating pressure.. Maximum operating pressure This indicates the limit of pressure that can be applied inside the pipelines. (Line pressure) (The pressure differential of the solenoid valve unit must be no more than the maximum operating pressure differential.). Withstand pressure The pressure which must be withstood without a drop in performance after returning to the operating pressure range (The value under the prescribed conditions). Other. Material : Nitrile rubber : Fluororubber : Ethylene propylene rubber C7: Brass SUS: Stainless steel Flat Terminal. Flat terminal/electrical connection size of molded coil Electrical Terminology. Surge voltage A high voltage which is momentarily generated in the shut-off unit by shutting off the power.. Enclosure A degree of protection defined in the JIS C 090: Waterproof test of electric machinery/appliance and the degree of protection against the intrusion of solid foreign objects. Verify the degree of protection for each product. IP Second characteristic numeral First characteristic numeral First Characteristics: Degrees of protection against solid foreign objects 0 Non-protected Protected against solid foreign objects of 0 mm ø and greater Protected against solid foreign objects of mm ø and greater Protected against solid foreign objects of. mm ø and greater Protected against solid foreign objects of.0 mm ø and greater Dust-protected Dusttight Second Characteristics: Degrees of protection against water Non-protected Protected against vertically falling water drops Protected against vertically falling water drops when enclosure tilted up to Protected against rainfall when enclosure tilted up to 0 Protected against splashing water Protected against water jets Protected against powerful water jets Protected against the effects of temporary immersion in water Protected against the effects of continuous immersion in water Dripproof type Dripproof type Rainproof type Splashproof type Low jetproof type Strong jetproof type Immersible type Submersible type Example) IP: Dusttight, Low jetproof type Low jetproof type means that no water intrudes inside an equipment that could hinder from operating normally by means of applying water for minutes in the prescribed manner. Take appropriate protection measures, since a device is not usable in an environment where a droplet of water is splashed constantly Chamfer. When providing a body ground, please use the frame ground (M.). (Recommended fastening bolt: M., length mm) 8. VCH B
Pilot Operated 2 Port Solenoid Valve for Dry Air
Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible
More information1.0 cm 3 /min. Pilot Operated 2-Port Solenoid Valve/ Zero Pressure Differential Operation Series VXS22/23. Compact and Lightweight mm.
Pilot Operated -Port Solenoid Valve/ Zero Pressure Differential Operation Series VXS/ Compact and Lightweight Enclosure: IP65 Low-noise construction Operation noise is reduced due to full wave rectifier
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion
More informationPilot Operated 2 Port Solenoid Valve for Dry Air
Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 MPa Pilot Operated /3 Port Solenoid Valve & Check Valve VCH Series VCH4/4: Port VCH40: 3 Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve [Option] VCH40 Series Stable responsiveness Response
More informationCompact / Lightweight 2 Port Solenoid Valve
ompact / Lightweight 2 Port Solenoid Valve /-XF For ir/water ompact / Lightweight resin body (PPS) Weight: 20 g (-XF) RoHS IP65 mm Power consumption 3 W (Standard) 0.5 W (With power-saving circuit) 48
More informationSeries AV2000/3000/4000/5000
Soft Start-up Valve Series AV/3/4/5 Series introduced! A start-up valve that gradually increases supply pressure during start up and rapidly exhausts system air when the supply air is shut off AC AV AU
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time
More informationCAT.ES70-22 A. Series VC. Direct Operated 2 Port Solenoid Valve for Heated Water. Series VCB
CAT.ES0- A Series VC Direct Operated Port Solenoid Valve for Heated Water Series VCB Multipurpose Valve for Heated Water Direct Operated Port Solenoid Valve for Heated Water Series VCB Improved durability
More information5 Port Solenoid Valve Direct Operated Poppet Type. Specifications
Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W
More information5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal
Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage
More information3 Port Solenoid Valve Direct Operated Poppet Type
3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage
More information5 Port Solenoid Valve Direct Operated Poppet Type. Specifications
Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W
More information3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot
3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion
More informationSoft Start-up Valve. AV2000/3000/4000/5000 Series
Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off
More informationVacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm
4 Port Direct Operated Poppet Solenoid Valve Series D1000 High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure
More informationBody width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.
High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure of 0.5MPa, subject to clean, dry air) 4 Port Direct
More informationSeries VC Direct Operated 2 Port Solenoid Valve for Oil. Series VCL VX VN VQ VDW VC LV PA
Series V irect Operated Port Solenoid Valve for Oil Series V VX VN V VW V V P.-9 Multipurpose Valve for Oil irect Operated Port Solenoid Valve for Oil Series V Kerosene, uel oil class (fuel oil ), Silicone
More informationSeries VP3145/3165/3185
Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes
More information10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry
Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion
More information3 Port Solenoid Valve
Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series
More informationCompact Proportional Solenoid Valve
Compact Proportional Solenoid Valve Series Repeatability: % or less Hysteresis:1% or less Fluid Flow rate control range Note) Series Air, Inert gas to L/min to L/min Note) Varies depending on the model.
More information3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.
3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118
More informationHigh Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series
Doc. No. High Vacuum Solenoid Valve PRODUCT NAME XSA Series MODEL/ Series Thank you for purchasing this SMC product. Be sure to read this Operation Manual carefully and understand its contents before operating
More informationHN B G1/US B G2/US B G3
HN B G/US B G/US B G Compact direct acting, port solenoid valve air, water,, low vacuum (. x 0 Pa (abs)) CONTENTS Safety precautions port solenoid valve HNB NC (normally closed) type USB NC (normally closed)
More informationVX Z. Zero Differential Pressure Type Pilot Operated 2 Port Solenoid Valve VXZ22/23. For Air, Water, Oil. New. Series
Zero Differential Pressure Type Pilot Operated Port Solenoid Valve For Air, Water, Oil Reduced power consumption ( spec.) VXZ: 8 W 7 W VXZ:.5 W.5 W New VX Z Z Series VXZ/ CAT.ES7-A Solenoid valves for
More informationIP65. Compact Direct Operated 2 Port Solenoid Valve. VDW Series. Aluminum Resin(PPS) g. Brass Stainless Steel. 15 mm mm
ompact irect Operated Port Solenoid Valve Series RoHS ir Medium Water vacuum Lightweight 80 g 00 luminum/resin(pps) body () ompact ody material luminum Resin(PPS) g ir urrent rass body () Water urrent
More informationDoc. no.vn-omm0001-c. Coolant valve PRODUCT NAME. VNC/VNH Series MODEL / Series / Product Number
Doc. no. Coolant valve PRODUCT NAME VNC/VNH Series MODEL / Series / Product Number Contents Safety Instructions ---------------------------------------------------------------------------------- 2,3 Precautions
More information3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option
Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable
More informationSeries VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4
Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double
More informationVacuum / Release Unit
Rubber Seal Vacuum / Release Unit Series VQD1000-V Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area Smooth detachment of a work piece without over-blow
More informationSeries VKF300 VV061 V100 S070 VQD VKF VK VT VS
Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing
More information3 Port Solenoid Valve
Rubber Seal Port Solenoid Valve Series Manifold Single Unit ase Mounted Manifold VV01 V100 ar base P.18 ody Ported P.10 ase Mounted P.10 VQD VKF VK VT VS Separable base ody Ported Manifold P.1 Stacking
More information1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions
Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]
More informationDoc. no.vn -OMA0002-D. Process valve PRODUCT NAME. VNA Series MODEL / Series / Product Number
Doc. no. Process valve PRODUCT NAME VNA Series MODEL / Series / Product Number Contents Safety Instructions ---------------------------------------------------------------------------------- 2,3 Design
More informationSpecifications. Fluid Ambient and fluid temperature ( C)
Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication
More informationSeries VP3145/3165/3185
Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to
More information13 msec (at 500 mm )/18.5 msec (at 1000 mm )
Vacuum / Release Unit Series VQD1000-V Rubber Seal Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area [Option] Smooth detachment of a work piece without
More information3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option
3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity
More informationAir Catch Sensor. Non-Contact Sensor for Workpiece Placement Confirmation
Air Catch Sensor Non-Contact Sensor for Workpiece Placement Confirmation Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact type
More informationDirect Operated 2 Port Solenoid Valve For Water, Oil, Steam, Air
CAT.ES0- A Direct Operated Port Solenoid Valve For Water, Oil, Steam, Air New Series VX// Reduction of power consumption ( specification) W. W W W. W 0. W Low power consumption type: 0. W (Held at V) New
More informationCoolant valve. SGC/SGH Series
Doc. no. PRODUCT NAME Coolant valve MODEL / Series / Product Number SGC/SGH Series Contents Safety Instructions ------------------------------------------------------------------------------------- 2,3
More informationAdded 100 mm and 150 mm lengths. Actuators 10% Air leakage 20% Air blow 70% Current model
Blow Gun Series 20% reduction in power consumption with the SMC Blow gun + S coupler + Coil tube 10% reduction with the Blow gun () only RoHS With cover Extension nozzle Added mm and 150 mm lengths Pressure
More informationHow to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.
Series -S00 ompact Direct Operated Port Solenoid Valve ontrol Valves ase mounted ody ported lean Series lean Series V S R oil voltage 24 VD VD VD VD VD Power consumption Pressure specification Flow rate
More informationNew Concept Connector Type Manifold
New Concept Connector Type Manifold Series /000/3000/000 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration.
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body
More informationHigh Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series
Doc. No. High Vacuum Solenoid Valve PRODUCT NAME XSA Series MODEL/ Series Thank you for purchasing this SMC product. Be sure to read this Operation Manual carefully and understand its contents before operating
More information3/4/5-Port Solenoid Valves Precautions 1 Be sure to read this before handling products.
Precautions 1 1. Confirm the specifications. Products represented in this catalog are designed only for use in compressed air systems (including vacuum). Do not operate at pressures, temperatures, etc.,
More informationNO (normally closed) type Common supply type (port C pressurization) MPa MPa MPa C C
Direct acting port solenoid valve, manifold and actuator (general purpose valve) NO (normally closed) type Common supply type (port C pressurization) Manifold circuit structure Common specifications B
More informationSeries VQ Port Solenoid Valve
Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body
More informationFlow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Enclosure
Paddle Style For details about certified products conforming to international standards, visit us at www.smcworld.com. Flow switches, series IF detect and confirm liquid, generally used in fields such
More informationFlow Switch Paddle Style Flow Switch IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type. (Equivalent to IP42)
Paddle Style [Option] Flow switches, series IF detect and confirm liquid, generally used in fields such as air conditioning, water supply equipment, etc. Piping sizes ranges from /4B to B. Wide range of
More informationInstallation and Maintenance Manual VXZ Zero Pressure Differential Type Pilot Operated 2 Port Solenoid Valve
2 Specifications Installation and Maintenance Manual VXZ Zero Pressure Differential Type Pilot Operated 2 Solenoid Valve For Air, Water, Oil, Heated Water, High Temperature Oil 1 Safety Instructions This
More informationFlow characteristics Max. (1) b Standard Specifications. P Manual override.
Port Direct Operated Solenoid Valve Series 0 Metal Seal Model Number of positions (Single) (Double) ( position) JIS Symbol Model Port size Rc (Nominal size) 0-0 8 ( A) 0- ( 8A) 0-0 8 (0A) 0-0 8 ( A) 0-
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body
More informationExhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)
5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust
More informationHigh Vacuum Solenoid Valve. 25% reduction. Max. Weight. 18% * lighter. Max. * XSA2-2 AC 100 V, 200 V, 110 V, 220 V, 240 V, 48 V, 24 V, 230 V DC
Normal lose High Vacuum Solenoid Valve Minimum operating pressure * 1x10 6 Pa(abs) * OUT side Leakage Internal 1.3 x10 9 Pa m3/s Note) Note) Except grommet/ RoHS External 1.3 x10 11 Pa m3/s 2 types of
More informationDiscrete direct acting 2 port solenoid valve (general purpose valve) AB31 AB41 Series NC (normally closed) type AB42 Series NO (normally open) type
31414 Series iscrete direct acting port solenoid valve (general purpose valve) 31 41 Series NC (normally closed) type 4 Series NO (normally open) type Port size: Rc1/8 to Rc1/ JIS symbol Common specifications
More information3 Port Solenoid Valve
Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly
More informationNon-Contact Sensor for Workpiece Placement Verification
ir Catch Sensor Series 2 Non-Contact Sensor for Workpiece Placement Verification Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact
More informationFlow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type (Equivalent to IP42)
Series IF [Option] Flow switches, series IF detect and confirm liquid, generally used in fields such as air conditioning, water supply equipment, etc. Piping sizes ranges from /B to B. Wide range of applicable
More information5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure
For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Series 000 Compact and lightweight: 3 mm width Compact yet provides
More informationPD3/PDV3-20A/25A/40A Series
Pilot operated 2-port valve for dust collector control (Large port size dust collector valve) PD3/PDV3-20A/25A/40A Series Air operated/with solenoid valve Port size: Rc3/4, Rc1, : Rc1 1 /2-: φ48, Rc1 1
More information4 Port Solenoid Valve
Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean
More information1.3 x % reduction 18% High Vacuum Solenoid Valve. XSA Series CAT.ES140-7B. 5 to 60 C
Normal lose igh Vacuum Solenoid Valve Minimum operating pressure x0 * 6 Pa(abs) * OUT side * * Excluding grommet/ RoS Leakage Internal.3 x0 9 Pa m3/s External.3 x0 Pa m3/s Max. Max. Power consumption 5%
More informationGeneral purpose direct acting 2, 3 port solenoid valve
eneral purpose direct acting, 3 port solenoid valve (eneral purpose valve) eneral purpose Direct acting, 3 port solenoid valve / Pilot operated/pilot kick type port solenoid valve P/D/PK/DK Page 9 9 P/
More information5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC)
Port Solenoid Valve/Direct Poppet Rubber seal Series VK3000 Nl/min 147 Compact/Width 18 X Length 8 (mm) Low power consumption 4W DC (Standard) 2W DC (Energy saver) Standard copper free specification All
More information4 Port Solenoid Valve
Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean
More informationDiscrete direct acting 3 port solenoid valve (general purpose valve) AG31/AG41 Series. Universal type Port size: Rc1/8, Rc1/4, Rc3/8
G3141 Series iscrete direct acting 3 port solenoid valve (general purpose valve) G31/G41 Series Universal type Port size: Rc1/8, Rc1/4, Rc3/8 JIS symbol G31/41: Universal type COM NO NC Common specifications
More informationFluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single
Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position
More informationNew Products COMPACT PILOT OPERATED SOLENOID VALVE FOR WATER. Lightweight and large flow rate, low power consumption Improved corrosion resistance!
New Products Compact Pilot Operated Solenoid Valve for Water FWD Series New Product COMPACT PILOT OPERATED SOLENOID VALVE FOR WATER Lightweight and large flow rate, low power consumption Improved corrosion
More information0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types
Speed 2 Port Valve Series RoHS speed speed speed response response response 5 ms 9mm Width ±0.05 ms ±0.05 ms type VCH : : 5 ms * The response time is measured based on SMC test conditions. (Not guaranteed
More information3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum
3 Port Direct Operated Poppet Rubber Seal Series 307 Large Flow Capacity, yet Compact Size. Dimensions (W X H X D) 30 X 54.5 X 33 307 Nl/min 206.02 or more, 1/4 Low Power Consumption /VO307 4.8W DC/Standard
More informationFlow Switch Diaphragm Style Flow Switch IFW5 10 N Diaphragm style flow switch. Thread type. Nil. Body size Note)
[Option] The flow switch, series IFW is used for detection and confirmation of the flow as a relaying device for the general water applications in some various equipment such as cooling water fixture in
More information1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption
Port Solenoid Valve Direct Operated Poppet Type Power consumption Vacuum applications New [Option] RoHS 4 Standard wtype (Existing product: 4.8 W) 0. kpa Energy-saving type.8 w (Existing product: W) A
More informationManual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry
Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal
More informationIndicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A
1 3 Port Air Operated Valve Series VTA301 JIS Symbol VTA 301 Indicate VO for manifold. Port size Specifications How to Order Without connection port (For manifold) 01 1/8 02 1/4 Option Fluid Air Operating
More informationTwo Hand Control Valve
Two Hand Control Valve Series n output is available through synchronized, twohanded operation (within 0.5 s)! Conforming to EN574 RoHS (Interchangeable with XT92-67 ) Example of a basic circuit diagram
More informationSeven Features of the Koganei Vacuum Valve
Seven Features of the Koganei Valve Koganei Original Solenoid Construction No burning damage to solenoid No need to stock solenoids as spare parts. Starting and energizing current values are extremely
More informationDiscrete direct acting 3 port solenoid valve (general purpose valve) NC pressurization type. Port size: Rc1/8, Rc1/4, Rc3/8
iscrete direct acting 3 port solenoid valve (general purpose valve) 33/43 Series pressurization type Port size: Rc1/8, Rc1/4, Rc3/8 Refer to nding 17 for more details. JIS symbol 33/43: pressurization
More informationKV series. Innovatively detachable Manifold Block. Smart Solenoid Valve (plug-in type, D-SUB multi-connector type)
CAT.1101E-S www.sym1.com KV series Innovatively detachable Manifold Block (DIN Rail Mounting) Smart Solenoid Valve (Plug-in type, D-SUB multi-connector ) Compact size with large flow capacity Exceedingly
More informationDiscrete direct acting 3 port solenoid valve (general purpose valve) Universal type Port size: Rc1/8, Rc1/4, Rc3/ to to 60 B
G31/41 Series iscrete direct acting 3 port solenoid valve (general purpose valve) G31/41 Series Universal type Port size: Rc1/8, Rc1/4, Rc3/8 Refer to nding 17 for more details. JIS symbol G31/41: Universal
More informationCIRCLE SEAL CONTROLS
CIRCLE SEAL CONTROLS ATKOMATIC SOLENOID VALVES INSTALLATION, MAINTENANCE, AND OPERATION INSTRUCTIONS 13000 SERIES Stainless, Normally Closed, Direct Lift, 3-Way Valve Installation Instructions WARNING:
More informationExclusively for air pressure system and air-hydro circuit control
Process Valve Series Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external
More informationCIRCLE SEAL CONTROLS
CIRCLE SEAL CONTROLS ATKOMATIC SOLENOID VALVES INSTALLATION, MAINTENANCE, AND OPERATION INSTRUCTIONS 3000 SERIES Bronze, Normally Closed, Direct Lift Installation Instructions WARNING: These instructions
More informationITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa
5.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator X Series This product is only for blowing gas. This product does not have sufficient pressure control for other applications (driving,
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3
More informationProcess Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control
Process Series Port For Compressed Air and Air-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Cylinder actuation by external air he balance poppet
More informationHVB/HVL. Solenoid valve for high vacuum. For vacuum, inert gas, air, nitrogen CONTENTS. Overview
HV/HVL For vacuum, inert gas, air, nitrogen HN/G US/G F/G Overview dvanced technology, such as stability in the leak amount (vacuum holding force) and increased seal life, is required when the degree of
More information2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control
Process Valve Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external pilot
More information5 Port Solenoid Valve
5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry
More informationHigh Pressure Coolant Valve
High Pressure Coolant Valve Series.5 MPa, 7.0 MPa Corresponding to high speed grinding and long drilling processes Coolant valve for high pressure coolant liquid (up to.5 MPa or 7.0 MPa) that is ideal
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model 2 position 3 position
More information3-in-1 package (solenoid valve + governor + solenoid valve) realizes compact piping in double shutoff application.
CC-1104A GHV Series 3-in-1 package (solenoid valve + governor + solenoid valve) realizes compact piping in double shutoff application. Main features Space-saving integrated structure Two solenoid valves
More informationSeries VXR21/22/23. Water Hammer Relief, Pilot Operated 2 Port Solenoid Valve. For Water and Oil
Water Hammer Relief, Pilot Operated Port Solenoid Valve Series VXR//3 For Water and Oil N.C. Variations Normally closed (N.C.) Normally open (N.O.) Option Option Body Seal N.O. BC6, Valve OUT IN OUT IN
More information2 Port Solenoid Valve For Dust Collector
The VX* series will be revised shortly. 2 Port Solenoid Valve For Dust Collector Series 2 port solenoid valve for dust collector Series In this L-shaped 2 port valve, the bag filter is cleaned by high
More information3 Port Air Operated Valve VTA. Indicate VO for manifold. Port size. Nil 02 1/4. Specifications Fluid. Option Description Bracket (With screw)
Series VTA301 How to Order VTA 301 Indicate VO for manifold. Port size Without connection port (For manifold) 01 1/8 02 1/4 F N T Option B Rc G NPT NPTF Without bracket Foot bracket JIS Symbol Specifications
More information