Operating Instructions KSR-TF 611 with contactless electronic switch

Size: px
Start display at page:

Download "Operating Instructions KSR-TF 611 with contactless electronic switch"

Transcription

1 Operating Instructions KSR-TF 6 with contactess eectronic switch

2 Contents Contents About this document. Function Target group Symboism used For your safety 2. Authorised personne Appropriate use Warning about misuse Genera safety instructions CE conformity SIL conformity Safety instructions for Ex areas Product description 3. Configuration Principe of operation Operation Storage and transport Mounting 4. Genera instructions Mounting instructions Connecting to power suppy 5. Preparing the connection Connection procedure Wiring pan, singe chamber housing Set up 6. In genera Adjustment eements Function chart Maintenance and faut rectification 7. Maintenance Faut rectification Instrument repair Dismounting 8. Dismounting steps Disposa KSR-TF 6 - with contactess eectronic switch

3 Contents 9 Suppement 9. Technica data Dimensions KSR-TF 6 - with contactess eectronic switch 3

4 About this document About this document. Function This operating instructions manua provides a the information you need for mounting, connection and setup as we as important instructions for maintenance and faut rectification. Pease read this information before putting the instrument into operation and keep this manua accessibe in the immediate vicinity of the device..2 Target group This operating instructions manua is directed to trained personne. The contents of this manua shoud be made avaiabe to these personne and put into practice by them..3 Symboism used Information, tip, note This symbo indicates hepfu additiona information. Caution: If this warning is ignored, fauts or mafunctions can resut. Warning: If this warning is ignored, injury to persons and/or serious damage to the instrument can resut. Danger: If this warning is ignored, serious injury to persons and/or destruction of the instrument can resut. Ex appications This symbo indicates specia instructions for Ex appications. à List The dot set in front indicates a ist with no impied sequence. Action This arrow indicates a singe action. Sequence Numbers set in front indicate successive steps in a procedure. 4 KSR-TF 6 - with contactess eectronic switch

5 For your safety 2 For your safety 2. Authorised personne A operations described in this operating instructions manua must be carried out ony by trained speciaist personne authorised by the operator. During work on and with the device the required persona protection equipment must aways be worn. 2.2 Appropriate use KSR-TF 6 is a sensor for eve detection. You can find detaied information on the appication range in chapter "Product description". 2.3 Warning about misuse Inappropriate or incorrect use of the instrument can give rise to appication-specific hazards, e.g. vesse overfi or damage to system components through incorrect mounting or adjustment. 2.4 Genera safety instructions This is a high-tech instrument requiring the strict observance of standard reguations and guideines. The user must take note of the safety instructions in this operating instructions manua, the country-specific instaation standards as we as a prevaiing safety reguations and accident prevention rues. The instrument must ony be operated in a technicay fawess and reiabe condition. The operator is responsibe for troubefree operation of the instrument. The user is aso obiged to determine, during the entire duration of use, the compiance of the necessary occupationa safety measures with the current vaid reguations and take note of new reguations. 2.5 CE conformity KSR-TF 6 is in CE conformity with EMC (89/336/EWG), fufis NAMUR recommendation NE 2 and is in CE conformity with LVD (73/23/EWG). Conformity has been judged according to the foowing standards: KSR-TF 6 - with contactess eectronic switch 5

6 For your safety EMC: - Emission EN 6326/A: 998 (cass B) - Susceptibiity EN 6326: 997/A:998 LVD: EN 600-: SIL conformity KSR-TF 6 fufis the requirements to functiona safety according to IEC 6508 or IEC 65. You find further information in the Safety Manua. 2.7 Safety instructions for Ex areas Pease note the Ex-specific safety information for instaation and operation in Ex areas. These safety instructions are part of the operating instructions manua and come with the Exapproved instruments. 6 KSR-TF 6 - with contactess eectronic switch

7 Product description 3 Product description 3. Configuration Scope of deivery Components The scope of deivery encompasses: KSR-TF 6 eve sensor Documentation - this operating instructions manua - Additiona instructions manua "Safety Manua - Functiona safety according to IEC 6508 (SIL)" - Ex-specific "Safety instructions" (with Ex-versions) - if necessary, further certificates KSR-TF 6 consists of the foowing components: Housing cover Housing with eectronics process fitting with tuning fork 2 3 Fig. : KSR-TF 6 Housing cover 2 Housing with eectronics 3 Process fitting 3.2 Principe of operation Area of appication KSR-TF 6 is a eve sensor with tuning fork for eve detection. It is designed for industria use in a areas of process technoogy and can be used in iquids. Typica appications are overfi and dry run protection. With a tuning fork of ony 40 mm ength, KSR-TF 6 can be aso mounted, e.g. in pipeines from DN 25. The sma tuning fork KSR-TF 6 - with contactess eectronic switch 7

8 Product description aows use in vesses, tanks and pipes. Thanks to its simpe and robust measuring system, KSR-TF 6 is virtuay unaffected by the chemica and physica properties of the iquid. It functions even under difficut conditions such as turbuence, air bubbes, foam generation, buidup, strong externa vibration or changing products. Faut monitoring The eectronics modue of KSR-TF 6 continuousy monitors via frequency evauation the foowing criteria: Strong corrosion or damage on the tuning fork oss of vibration Line break to the piezo drive If a mafunction is detected or in case of power faiure, the eectronics takes on a defined switching condition, i.e. the contactess eectronic switch opens (safe condition). Functiona principe Suppy The tuning fork is piezoeectricay energised and vibrates at its mechanica resonance frequency of approx. 200 Hz. The piezos are fixed mechanicay and are hence not subject to temperature shock imitations. The frequency changes when the tuning fork is covered by the medium. This change is detected by the integrated osciator and converted into a switching command. KSR-TF 6 is a compact instrument, i.e. it can be operated without externa evauation system. The integrated eectronics evauates the eve signa and outputs a switching signa. With this switching signa, a connected device can be operated directy (e.g. a warning system, a PLC, a pump etc.). The data for power suppy are stated in chapter "Technica data" in the "Suppement". 3.3 Operation With the factory setting, products with a density >0.07 g/cm³ (>0.025 bs/in³) can be measured. The instrument can be adapted if products with ower density shoud be measured. On the eectronics modue you wi find the foowing indicating and adjustment eements: signa amp for indication of the switching condition (green/ red) DIL switch for sensitivity adjustment 8 KSR-TF 6 - with contactess eectronic switch

9 Product description Mode switch for seection of the switching condition (A/B) 3.4 Storage and transport Packaging Storage and transport temperature Your instrument was protected by packaging during transport. Its capacity to hande norma oads during transport is assured by a test according to DIN EN The packaging of standard instruments consists of environment-friendy, recycabe cardboard. In addition, the sensor is provided with a protective cover of ABS. For specia versions PE foam or PE foi is aso used. Dispose of the packaging materia via speciaised recycing companies. Storage and transport temperature see "Suppement - Technica data - Ambient conditions" Reative humidity % KSR-TF 6 - with contactess eectronic switch 9

10 Mounting 4 Mounting 4. Genera instructions Switching point In genera, KSR-TF 6 can be mounted in any position. The instrument must be mounted in such a way that the tuning fork is at the height of the requested switching point. The tuning fork has atera markings (notches) that indicate the switching point with vertica mounting. The switching point refers to water with the basic setting of the sensitivity switch 0.7 g/cm³ (0.025 bs/in³). When mounting KSR-TF 6, make sure that this marking is at the height of the requested switching point. Keep in mind that the switching point of the instrument is shifted if the medium has a density other than water - water g/cm³ (0.036 bs/in³). For products <0.7 g/cm³ (0.025 bs/in³) and >0.5 g/cm³ (0.08 bs/in³) the density switch must be set to 0.5 g/cm³. Keep in mind that foams with a density >0.45 g/cm³ (0.06 bs/ in³) are detected by the sensor. This can cause fauty switchings particuary when used as dry run protection system Fig. 2: Vertica mounting Switching point approx. 3 mm (0.5 in) 2 Switching point with ower density 3 Switching point with higher density 4 Switching point approx. 27 mm (.06 in) 0 KSR-TF 6 - with contactess eectronic switch

11 Mounting Fig. 3: Horizonta mounting Switching point 2 Fig. 4: Vertica instaation (recommended instaation position, especiay for adhesive products) Switching point 2 Marking with screwed version on top, with fange versions directed to the fange hoes With fange versions, the fork is directed as foows to the fange hoes. Fig. 5: Fork position with fange versions Moisture Use the recommended cabes (see chapter "Connecting to power suppy") and tighten the cabe gand. You can give your KSR-TF 6 additiona protection against moisture penetration by eading the connection cabe downward in front of the cabe entry. Rain and condensation water KSR-TF 6 - with contactess eectronic switch

12 Mounting can thus drain off. This appies mainy to mounting outdoors, in areas where moisture is expected (e.g. by ceaning processes) or on cooed or heated vesses. Fig. 6: Measures against moisture penetration Transport Pressure/Vacuum Handing Do not hod KSR-TF 6 on the tuning fork. Particuary with fange or tube versions, the tuning fork can be damaged just by the weight of the instrument. Transport coated instruments very carefuy and avoid touching the tuning fork. Remove the protective cover just before mounting. The process fitting must be seaed if there is gauge or ow pressure in the vesse. Before use, check if the sea materia is resistant against the measured product and the process temperature. The max. permissibe pressure is stated in chapter "Technica data" in the "Suppement" or on the type abe of the sensor. The vibrating eve switch is a measuring instrument and must be treated accordingy. Bending the vibrating eement wi destroy the instrument. Warning: The housing must not be used to screw the instrument in! Appying tightening force on the housing can damage its rotationa mechanica parts. To screw in, use the hexagon above the thread. 2 KSR-TF 6 - with contactess eectronic switch

13 Mounting 4.2 Mounting instructions Weded socket KSR-TF 6 has a defined thread starting point. This means that every KSR-TF 6 is in the same fork position after being screwed in. Remove therefore the suppied sea from the thread of KSR-TF 6. This sea is not required when using a weded socket with O-ring in front. Keep in mind that this weded socket is not suitabe for coated instrument versions. Screw KSR-TF 6 competey into the weded socket. The ater position can be determined aready before weding. Mark the appropriate position of the weded socket. Before weding, unscrew KSR-TF 6 and remove the rubber ring from the weded socket. The weded socket has a marking (notch). Wed the socket with the notch facing upward, or in case of pipeines, aigned with the direction of fow. Fig. 7: Marking on the weded socket Marking Adhesive products In case of horizonta mounting in adhesive and viscous products, the surfaces of the tuning fork shoud be vertica in order to reduce buidup on the tuning fork. On the screwed version you wi find a marking on the hexagon. With this, you can check the position of the tuning fork when screwing it in. When the hexagon touches the sea, the thread can sti be turned by approx. haf a turn. This is sufficient to reach the recommended instaation position. With fange versions, the fork is directed to the fange hoes. When used in adhesive and viscous products, the tuning fork shoud protrude into the vesse to avoid buidup. For that reason, sockets for fanges and mounting bosses shoud be avoided when mounting horizontay. KSR-TF 6 - with contactess eectronic switch 3

14 Mounting Infowing medium Fows If KSR-TF 6 is mounted in the fiing stream, unwanted mismeasurements may resut. Mount KSR-TF 6 at a ocation in the vesse where no disturbing infuence from e.g. fiing openings, agitators, etc. can occur. To minimise fow resistance caused by the tuning fork, KSR-TF 6 shoud be mounted in such a way that the surfaces of the bades are parae to the product movement. 4 KSR-TF 6 - with contactess eectronic switch

15 Connecting to power suppy 5 Connecting to power suppy 5. Preparing the connection Note safety instructions Take note of safety instructions for Ex appications Seect power suppy Seecting connection cabe Aways keep in mind the foowing safety instructions: Connect ony in the compete absence of ine votage In hazardous areas you shoud take note of the appropriate reguations, conformity and type approva certificates of the sensors and power suppy units. Connect the power suppy according to the foowing diagrams. Osciator SWE60C is designed in protection cass. To maintain this protection cass, it is absoutey necessary that the ground conductor be connected to the interna ground termina. Take note of the genera instaation reguations. As a rue, connect KSR-TF 6 to vesse ground (PA), or in case of pastic vesses, to the next ground potentia. On the side of the housing there is a ground termina between the cabe entries. This connection serves to drain off eectrostatic charges. In Ex appications, the instaation reguations for hazardous areas must be given priority. The data for power suppy are stated in chapter "Technica data" in the "Suppement". KSR-TF 6 is connected with standard cabe with round cross section. An outer cabe diameter of 5 9 mm ( in) ensures the sea effect of the cabe gand. If cabe with a different diameter or wire cross section is used, exchange the sea or use an appropriate cabe connection. In hazardous areas, ony use approved cabe connections for KSR-TF 6. Seect connection cabe for Ex appications Take note of the corresponding instaation reguations for Ex appications. 5.2 Connection procedure With Ex instruments, the housing cover may ony be opened if there is no exposive atmosphere present. Proceed as foows: KSR-TF 6 - with contactess eectronic switch 5

16 Connecting to power suppy Unscrew the housing cover 2 Loosen compression nut of the cabe entry 3 Remove approx. 0 cm (4 in) of the cabe mante, strip approx. cm (0.4 in) insuation from the ends of the individua wires 4 Insert the cabe into the sensor through the cabe entry 5 Open the terminas with a screwdriver 6 Insert the wire ends into the open terminas according to the wiring pan 7 Tighten the terminas with a screwdriver 8 Check the hod of the wires in the terminas by ighty puing on them 9 Tighten the compression nut of the cabe entry. The sea ring must competey encirce the cabe 0 Screw the housing cover back on The eectrica connection is finished. 5.3 Wiring pan, singe chamber housing The foowing iustrations appy to the non-ex as we as to the EEx d version. Housing overview Fig. 8: Materia versions, singe chamber housing Auminium 2 Stainess stee 3 Fiter eement for pressure compensation 6 KSR-TF 6 - with contactess eectronic switch

17 Connecting to power suppy Eectronics and connection compartment 5 SW E60C V A C /DC max 4 00mA L + L N N A B 0,5 g / cm 3 0,7 g / cm Fig. 9: Eectronics and connection compartment, singe chamber housing Contro amp 2 DIL switch for mode adjustment 3 DIL switch for switching point adaptation 4 Ground termina 5 Screwed terminas Wiring pan We recommend connecting KSR-TF 6 in such a way that the switching circuit is open when there is a eve signa, ine break or faiure (safe condition). The contactess eectronic switch is aways shown in nonoperative condition. The instrument is used for direct contro of reays, contactors, magnet vaves, warning ights, horns etc. It must not be operated without an intermediatey connected oad, because the eectronics woud be destroyed if connected directy to the mains. It is not suitabe for connection to ow votage PLC inputs. Domestic current is temporariy owered beow ma after switching off the oad so that contactors, whose hoding current is ower than the constant domestic current of the eectronics, are reiaby switched off. When KSR-TF 6 is used as part of an overfi protection system according to WHG, aso note the reguations of the genera type approva. KSR-TF 6 - with contactess eectronic switch 7

18 Connecting to power suppy 2 AC DC L N Fig. 0: Wiring pan, singe chamber housing 8 KSR-TF 6 - with contactess eectronic switch

19 Set up 6 Set up 6. In genera The numbers in brackets refer to the foowing iustrations. Function/Configuration In the basic setting, products with a density >0.7 g/cm³ (0.025 bs/in³) can be detected. For products with ower density, you have to set the switch to >0.5 g/cm³ (0.08 bs/ in³). On the eectronics modue you wi find the foowing indicating and adjustment eements: Signa amp () DIL switch for mode adjustment - A/B (2) DIL switch for sensitivity adjustment (3) Note: For test purposes, immerse the tuning fork of KSR-TF 6 aways in iquids. Do not test the function of KSR-TF 6 with the hand. This can damage the sensor. 6.2 Adjustment eements Fig. : Osciator SWE60C - Contactess eectronic switch Signa amp (LED) 2 DIL switch for mode adjustment 3 DIL switch for sensitivity adjustment KSR-TF 6 - with contactess eectronic switch 9

20 Set up Signa amp () Mode adjustment (2) Sensitivity adjustment (3) Contro amp (LED) for indication of the switching status. green = output conducts red = output bocks red (fashing) = faiure With the mode adjustment (A/B) you can change the switching condition of the reay. You can set the required mode according to the "Function chart" (A - max. detection or overfi protection, B - min. detection or dry run protection). With this DIL switch (3) you can set the switching point to iquids having a density between 0.5 and 0.7 g/cm³ (0.08 and bs/in³). With the basic setting, iquids with a density of >0.7 g/cm³ (0.025 bs/in³) can be detected. In iquids with ower density, you must set the switch to >0.5 g/cm³ (0.08 bs/in³). The specifications for the position of the switching point reate to water - density vaue g/cm³ (0.036 bs/in³). In products with a different density, the switching point wi shift in the direction of the housing or tuning fork end depending on the density and type of instaation. Keep in mind that foams with a density >0.45 g/cm³ (0.06 bs/ in³) are detected by the sensor. This can cause fauty switchings particuary when used as dry run protection system. 6.3 Function chart The foowing chart provides an overview of the switching conditions depending on the adjusted mode and eve. Mode A Overfow protection Leve Switching status Contro amp 2 Mode A Overfow protection Switch cosed Green 2 Mode B Dry run protection Switch open Red 2 Switch cosed Green 20 KSR-TF 6 - with contactess eectronic switch

21 Set up Mode B Dry run protection Leve Switching status Contro amp 2 Switch open Red Faiure of the suppy votage (mode A/B) any 2 Switch open Faiure any 2 Switch open fashes red KSR-TF 6 - with contactess eectronic switch 2

22 Maintenance and faut rectification 7 Maintenance and faut rectification 7. Maintenance When used as directed in norma operation, KSR-TF 6 is competey maintenance free. 7.2 Faut rectification Causes of mafunction Faut cearance KSR-TF 6 offers maximum reiabiity. Nevertheess fauts can occur during operation. These may be caused by the foowing, e.g.: Sensor Process Suppy Signa processing The first measure to be taken is to check the output signa. In many cases, the causes can be determined this way and the fauts rectified. Checking the switching signa? KSR-TF 6 signas "covered" when the vibrating eement is not submerged (overfi protection)? KSR-TF 6 signas "uncovered" when the vibrating eement is submerged (dry run protection) Suppy votage too ow à Check the power suppy Eectronics modue defective à Press the mode switch (min./max.). If the instrument then changes the mode, the instrument may be mechanicay damaged. Shoud the switching function in the correct mode sti be fauty, return the instrument for repair. à Push the mode switch. If the instrument then does not change the mode, the osciator may be defective. Exchange the osciator. à Check if there is buidup on the vibrating eement, and if so, remove it. Unfavourabe instaation ocation à Mount the instrument at a ocation in the vesse where no dead zones or air bubbes can form. 22 KSR-TF 6 - with contactess eectronic switch

23 Maintenance and faut rectification Wrong mode seected à Set the correct mode on the mode switch (max.: overfi protection, min.: dry run protection). Wiring shoud be carried out according to the quiescent current principe.? Signa amp fashes red Eectronics has detected a faiure à Exchange instrument or return instrument for repair? The signa amp fashes aternatey red and green instrument defective à Exchange instrument or return instrument for repair 7.3 Instrument repair If a repair is necessary, pease proceed as foows: Cean the instrument and pack it damage-proof Attach a description of the faut, the ambient conditions and measured product to the instrument If necessary, attach a safety sheet to the instrument Send the instrument to the address of the agency serving you, in Germany directy to the headquarters KSR-TF 6 - with contactess eectronic switch 23

24 Dismounting 8 Dismounting 8. Dismounting steps Warning: Before dismounting, be aware of dangerous process conditions such as e.g. pressure in the vesse, high temperatures, corrosive or toxic products etc. Take note of chapters "Mounting" and "Connecting to power suppy" and carry out the isted steps in reverse order. With Ex instruments, the housing cover may ony be opened if there is no exposive atmosphere present. 8.2 Disposa The instrument consists of materias which can be recyced by speciaised recycing companies. We use recycabe materias and have designed the eectronics to be easiy separabe. WEEE directive 2002/96/EG This instrument is not subject to the WEEE directive 2002/96/ EG and the respective nationa aws (in Germany, e.g. EektroG). Pass the instrument directy on to a speciaised recycing company and do not use the municipa coecting points. These may be used ony for privatey used products according to the WEEE directive. Correct disposa avoids negative effects to persons and environment and ensures recycing of usefu raw materias. Materias: see chapter "Technica data" If you cannot dispose of the instrument propery, pease contact us about disposa methods or return. 24 KSR-TF 6 - with contactess eectronic switch

25 Suppement 9 Suppement 9. Technica data Genera data Materia 36L corresponds to.4404 or.4435 Materias, wetted parts - Process fitting - thread 36L, Hasteoy C4 (2.4602) - Process fitting - fange 36L, 36L with Hasteoy C4 pated, 36L with ECTFE coated, 36L with PFA coated - Process sea Kingersi C-4400 (with threaded versions) - Tuning fork 36L, Hasteoy C4 (2.460) - Extension tube ø 2.3 mm (0.84 in) 36L, Hasteoy C4 (2.460), 36L with ECTFE coating, 36L with PFA coating Sensor ength - ength KSR-TF 6 See chapter "Suppement - Dimensions" Materias, non-wetted parts - Housing Auminium die-casting powder coated, 36L - Sea between housing and housing cover - Ground termina 36L - Temperature adapter (optiona) 36L - Gas-tight eadthrough (optiona) 36L/gass Weights - Auminium housing 70 g (4 oz) - Stainess stee housing 530 g (54 oz) NBR (stainess stee housing), siicone (Auminium housing) Layer thickness - coatings - ECTFE approx. 0.5 mm (0.02 in) - PFA approx. 0.5 mm (0.02 in) Surface quaity - Standard R a approx. 3 µm (.8-4 in) - hygienic version (3A) R a <0.8 µm (3.5-5 in) - hygienic version (3A) R a <0.3 µm (.8-5 in) KSR-TF 6 - with contactess eectronic switch 25

26 Suppement Process fittings - Thread G¾ A, ¾ NPT, G A, NPT - Fanges DIN from DN 25, ANSI from " - hygienic fittings Boting DN 40 PN 40, Tri-Camp ", Tri-Camp ½" PN 0, conus DN 25 PN 40, Tuchenhagen Varivent DN 50 PN 0 Gas-tight eadthrough (optiona) - eakage rate <0-6 mbar /s - Pressure resistance PN 64 - hygienic fittings Boting DN 40 PN 40, Tri-Camp ", Tri-Camp ½" PN 0, conus DN 25 PN 40, Tuchenhagen Varivent DN 50 PN 0 Output variabe Output Contactess eectronic switch Modes (adjustabe) - A Max. detection or overfow/overfi protection - B Min. detection or dry run protection Measuring accuracy Deviation ± mm (±0.04 in) Infuence of the process temperature on the switching point 26 KSR-TF 6 - with contactess eectronic switch

27 Suppement 4 0 ( 25/64") 8 ( 5/6") 3 6 ( 5/64") 4 ( 5/32") 2 ( 5/64") 0-2 (-5/64") -4 (-5/32") 2-6 (-5/64") -8 (-5/6") -0 (-25/64") 0 C (32 F) 50 C (22 F) 00 C (22 F) 50 C (302 F) 200 C (392 F) 250 C (482 F) Fig. 25: Infuence of the process temperature on the switching point Shifting of the switching point in mm (in) 2 Process temperature in C ( F) 3 Switching point at reference conditions (notch) 4 Tuning fork Infuence of the product density on the switching point KSR-TF 6 - with contactess eectronic switch 27

28 Suppement 6 0 ( 25/64") 8 ( 5/6") 6 ( 5/64") 4 ( 5/32") 5 2 ( 5/64") 0-2 (-5/64") -4 (-5/32") -6 (-5/64") (-5/6") -0 (-25/64") 0,6 (0,022) 0,8 (0,029) (0,036),2 (0,043),4 (0,05),6 (0,058),8 (0,065) 2 (0,072) 2,2 (0,079) 2,4 (0,087) Fig. 26: Infuence of the product density on the switching point Shifting of the switching point in mm (in) 2 Product density in g/cm³ (b/in³) 3 Switch position 0.5 g/cm³ (corresponds to 0.08 b/in³) 4 Switch position 0.7 g/cm³ (corresponds to b/in³) 5 Switching point at reference conditions (notch) 6 Tuning fork Infuence of the process pressure to the switching point 28 KSR-TF 6 - with contactess eectronic switch

29 Suppement 4 0 ( 25/64") 8 ( 5/6") 3 6 ( 5/64") 4 ( 5/32") 2 ( 5/64") 0-2 (-5/64") -4 (-5/32") 2-6 (-5/64") -8 (-5/6") -0 (-25/64") 2 (74,) 25 (362,6) 38 (55,) 5 (739,7) 64 (928,2) Fig. 27: Infuence of the process pressure to the switching point Shifting of the switching point in mm (in) 2 Process pressure in bar (psi) 3 Switching point at reference conditions (notch) 4 Tuning fork Repeatabiity Hysteresis Switching deay Frequency Ambient conditions Ambient temperature on the housing Storage and transport temperature 0. mm (0.004 in) approx. 2 mm (0.08 in) with vertica instaation approx. 500 ms (on/off) approx. 200 Hz C ( F) C ( F) Process conditions Parameter Process pressure KSR-TF 6 of 36L/Hasteoy C4 (2.460) Limit eve of iquids - 64 bar ( psi) depending on the process fitting, e.g. fange (see foowing diagrams) C ( F) KSR-TF 6 - with contactess eectronic switch 29

30 Suppement Process temperature (thread or fange temperature) with temperature adapter (option) - KSR-TF 6 of 36L/Hasteoy C C ( F) - KSR-TF 6 with ECTFE coating C ( F) - KSR-TF 6 with PFA coating C ( F) 2 70 C (58 F) 3 40 C (04 F) 0 C (32 F) -50 C (-58 F) -40 C (-40 F) 50 C (22 F) 00 C (22 F) 50 C (302 F) 200 C (392 F) 250 C (482 F) Fig. 28: Ambient temperature - Process temperature Process temperature in C ( F) 2 Ambient temperature in C ( F) 3 Temperature range with temperature adapter 64 (928) 40 (580) 20 (290) -50 C (-58 F) - (-4,5) 0 C (32 F) 50 C (22 F) 00 C (22 F) 50 C (302 F) 200 C (392 F) 250 C (482 F) 2 Fig. 29: Process temperature - Process pressure with switch position 0.7 g/cm³ (mode switch) Process pressure in bar (psi) 2 Process temperature in C ( F) 30 KSR-TF 6 - with contactess eectronic switch

31 Suppement 64 (928) 40 (580) 20 (290) -50 C (-58 F) - (-4,5) 0 C (32 F) 50 C (22 F) 00 C (22 F) 50 C (302 F) 200 C (392 F) 250 C (482 F) 2 Fig. 30: Process temperature - Process pressure with switch position 0.5 g/cm³ (mode switch) Process pressure in bar (psi) 2 Process temperature in C ( F) Viscosity - dynamic Density 0. 0,000 mpa s (requirement: with density ) g/cm³ ( bs/in³); g/cm³ ( bs/in³) by switching over Eectromechanica data Cabe entry/pug (dependent on the version) - Singe chamber housing x cabe entry M20x.5 (cabe-ø 5 9 mm), x bind stopper M20x.5; attached x cabe entry M20x.5 or: x cabe entry ½ NPT, x bind stopper ½ NPT, x cabe entry ½ NPT Screw terminas Adjustment eements or: x pug M2x, x bind stopper M20x.5 for wire cross-section up to.5 mm² ( in²) Mode switch - A Max. detection or overfow/overfi protection - B Min. detection or dry run protection KSR-TF 6 - with contactess eectronic switch 3

32 Suppement Density switch g/cm³ ( oz/in³) g/cm³ ( oz/in³) Votage suppy Suppy votage Domestic current requirement Load current - Min. 0 ma V AC, 50/60 Hz, V DC approx. 3 ma (via oad circuit) - Max. 400 ma (with I> 300 ma the ambient temperature can be max. 60 C) max. 4 A up to 40 ms (not WHG specified) Eectrica protective measures Protection IP 66/IP 67 Overvotage category Protection cass Functiona safety (SIL) Functiona safety according to IEC 6508/IEC 65 - Singe channe architecture (oo up to SIL2 D) III I - Mutipe channe architecture see suppementary instructions manua "Safety Manua (SIL)" Approvas ) Overfi protection according to WHG ATEX II G /2G, 2G EEx ia IIC T6 ATEX II /2G, 2G EEx d IIC T6 2) FM (NI) CL I, DIV 2, GP ABCD FM (XP) CL I, DIV, GP ABCD (DIP) CL II, III, DIV, GP EFG 3) Ship approvas ) Deviating data in Ex appications: see separate safety instructions. 2) Ony with Auminium housing. 3) Ony with Auminium housing. 32 KSR-TF 6 - with contactess eectronic switch

33 Suppement 9.2 Dimensions KSR-TF 6 69mm (2 23/ 32") ø77mm (3 / 32") 6mm (4 9/ 6") ø84mm (3 5/ 6") M20x,5/ ½ NPT 7mm (4 39/64") M20x,5/ ½ NPT 6mm (4 9/6") M20x,5 2 Fig. 3: Housing versions Stainess stee housing 2 Auminium housing KSR-TF 6 - with contactess eectronic switch 33

34 Suppement KSR-TF 6 8,5 mm (47/64") 66 mm (2 23/32") 32 (G3/ 4 A, 3/ 4 "NPT) 4 (GA, "NPT) G3/ 4 A, 3/ 4 "NPT GA, "NPT 36 mm ( 27/64") 53 mm (2 3/32") 57 mm (2 /4") 55 mm (2 /64") mm ( 3/32") ø 33,7 mm ( 2/ 64 ") 9 mm (3/4") 34 mm ( /32") 6 78 mm (7 /64") 7 53 mm (2 3/32") 53 mm (2 3/32") 4 5 Fig. 32: KSR-TF 6 Thread 2 Tri-Camp 3 Cone DN 25 4 Boting DN 40 5 Fange 6 Gas-tight eadthrough 7 Temperature adapter 34 KSR-TF 6 - with contactess eectronic switch

35 Suppement KSR-TF 6 - with contactess eectronic switch 35

36 KSR KUEBLER Niveau-Messtechnik AG Im Kohstatterfed Zwingenberg Germany Phone Fax E-mai: info@de.ksr-kueber.com A statements concerning scope of deivery, appication, practica use and operating conditions of the sensors and processing systems correspond to the information avaiabe at the time of printing. Subject to change without prior notice

Operating Instructions OPTISWITCH 5100 C, 5150 C with contactless electronic switch

Operating Instructions OPTISWITCH 5100 C, 5150 C with contactless electronic switch Operating Instructions OPTISWITCH 5100 C, 5150 C with contactless electronic switch Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety

More information

Operating Instructions OPTISWITCH 5200 C, 5250 C with contactless electronic switch

Operating Instructions OPTISWITCH 5200 C, 5250 C with contactless electronic switch Operating Instructions OPTISWITCH 5200 C, 5250 C with contactless electronic switch Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety

More information

Operating Instructions OPTISWITCH 4000 C with transistor output

Operating Instructions OPTISWITCH 4000 C with transistor output Operating Instructions OPTISWITCH 4000 C with transistor output Contents Contents 1 About this document 1.1 Function... 3 1.2 Target group... 3 1.3 Symbolism used... 3 2 For your safety 2.1 Authorised

More information

Operating Instructions OPTISWITCH 5100 C, 5150 C with transistor output

Operating Instructions OPTISWITCH 5100 C, 5150 C with transistor output Operating Instructions OPTISWITCH 5100 C, 5150 C with transistor output Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety 2.1 Authorised

More information

Operating Instructions OPTISWITCH 5200 C, 5250 C with transistor output

Operating Instructions OPTISWITCH 5200 C, 5250 C with transistor output Operating Instructions OPTISWITCH 5200 C, 5250 C with transistor output Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety 2.1 Authorised

More information

Operating Instructions OPTISWITCH 5200 C, 5250 C with NAMUR output

Operating Instructions OPTISWITCH 5200 C, 5250 C with NAMUR output Operating Instructions OPTISWITCH 5200 C, 5250 C with NAMUR output Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety 2.1 Authorised

More information

Operating Instructions April 2008 SITRANS LVL200E

Operating Instructions April 2008 SITRANS LVL200E Operating Instructions April 2008 SITRANS LVL200E Content Content About this document. Function............................. 4.2 Target group.......................... 4.3 Symbolism used.......................

More information

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX) Operating Instructions VEGASWING 61, 63 with oscillator SW E60N (EX) Contents Contents Safety information... 2 Note Ex area... 2 1 Product description... 3 2 Function and application... 4 2.1 Principle

More information

Operating Instructions April 2008 SITRANS LVL100

Operating Instructions April 2008 SITRANS LVL100 Operating Instructions April 2008 SITRANS LVL100 Content Content 1 About this document 1.1 Function............................. 4 1.2 Target group.......................... 4 1.3 Symbolism used.......................

More information

Instruction Manual September 2010 SITRANS LVL200S

Instruction Manual September 2010 SITRANS LVL200S Instruction Manual September 200 SITRANS LVL200S Contents Contents About this document. Function.................................. 4.2 Target group.............................. 4.3 Symbolism used............................

More information

Product Information. Process pressure/hydrostatic Pressure transmitter VEGABAR 51, 52, 53, 54, 55

Product Information. Process pressure/hydrostatic Pressure transmitter VEGABAR 51, 52, 53, 54, 55 Product Information Process pressure/hydrostatic Pressure transmitter VEGABAR 5, 5, 5, 54, 55 Contents Contents Measuring principe.......................................................................................

More information

Operating Instructions 07/2013

Operating Instructions 07/2013 Vibrating Switches SITRANS LVL100 - transistor (PNP) Operating Instructions 07/2013 2 SITRANS LVL100 - Operating Instructions Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3

More information

OPTISWITCH 4000/5000. Vibration level switches for liquids

OPTISWITCH 4000/5000. Vibration level switches for liquids OPTISWITCH 4000/5000 Technical Datasheet Vibration level switches for liquids Operates up to 250 C / 480 F and 64 bar / 925 psi Pump dry-run detection High reliability due to permanent fault monitoring

More information

Operating Instructions OPTISWITCH 5200 C, 5250 C

Operating Instructions OPTISWITCH 5200 C, 5250 C Operating Instructions OPTISWITCH 5200 C, 5250 C Transistor (NPN/PNP) Document ID: 30432 2 Contents Contents 1 About this document 1.1 Function... 3 1.2 Target group... 3 1.3 Symbols used... 3 2 For your

More information

Operating Instructions 11/2015

Operating Instructions 11/2015 Vibrating Switches SITRANS LVL200E NAMUR Operating Instructions 11/2015 2 SITRANS LVL200E - Operating Instructions Contents 1 About this document 1.1 Function... 5 1.2 Target group... 5 1.3 Symbols used...

More information

GXL SERIES. DC 2-wire type Micro-size Inductive Proximity Sensor. High performance in micro-size design. Versatile mounting. Reduced wiring operation

GXL SERIES. DC 2-wire type Micro-size Inductive Proximity Sensor. High performance in micro-size design. Versatile mounting. Reduced wiring operation 777 PHOTO PHOTO DC -wire Micro-size Inductive Proximity SERIES Reated Information Genera terms and conditions... F-17 Gossary of terms... P.16~ seection guide... P.77~ Genera precautions... P. Conforming

More information

Precision Ground Plates and Flat Bars. Lifting and Clamping Devices. Ground Precision Components. Elastomer-Bars, -Sheets, -Sections

Precision Ground Plates and Flat Bars. Lifting and Clamping Devices. Ground Precision Components. Elastomer-Bars, -Sheets, -Sections A B C D E F G H J K L Die Sets Precision Ground Pates and Fat Bars Lifting and Camping Devices Shanks, ifter studs, eyebots Camping caws, screws and bots Guide eements Ground Precision Components Springs

More information

GXL SERIES. DC 2-wire type Micro-size Inductive Proximity Sensor. High performance in micro-size design. Reduced wiring operation. Versatile mounting

GXL SERIES. DC 2-wire type Micro-size Inductive Proximity Sensor. High performance in micro-size design. Reduced wiring operation. Versatile mounting 1 DC -wire Micro-size Inductive Proximity SERIES Reated Information Genera terms and conditions... F- Gossary of terms... P.176~ guide... P.71~ Genera precautions... P.179~ PHOTO PHOTO IGHT FOW PARTICUAR

More information

Overview. The MicorTIG series at a glance

Overview. The MicorTIG series at a glance www.orch.com.au Overview Lorch, word-eading, new, a in one resonance technoogy that enabes the next generation of portabe machines to operate from mains suppy, sma generators and batteries a deivering

More information

Mechanical Level Switches

Mechanical Level Switches Mechanica Leve Switches SOR mechanica eve switches are rugged, industria products specificay designed for versatiity of appication. This cataog contains appication and ordering data for foat and dispaceroperated

More information

EC Series GMS200C. Generator Set Specification. Your Partner for Power. Page of 5

EC Series GMS200C. Generator Set Specification. Your Partner for Power. Page of 5 EC Series Generator Set Specification Your Partner for Power Page - 1 - of 5 3-Phase, 50Hz@1500RPM Prime Power Standby Power Votage kw kva Amps 380 160 200 303.9 400 160 200 288.7 415 160 200 278.2 440

More information

Clamping devices. CLAMPEX clamping elements offer new possibilities as a shaft-hub-connection:

Clamping devices. CLAMPEX clamping elements offer new possibilities as a shaft-hub-connection: Keyess camping devices Camping devices Genera description: CLAMPEX are keyess camping devices designed to transmit torque via friction on mating components. These designs produce high transmittabe torque

More information

ANTILOCK BRAKE SYSTEM

ANTILOCK BRAKE SYSTEM SECTION 4F ANTILOCK BRAKE SYSTEM Caution: Disconnect the negative battery cabe before removing or instaing any eectrica unit or when a too or equipment coud easiy come in contact with exposed eectrica

More information

Vibrating Level Switch TF 511, TF 611, TF 633

Vibrating Level Switch TF 511, TF 611, TF 633 evel measurement Vibrating evel Switch TF 511, TF 611, TF 633 Applications Chemical industry, petrochemical, offshore, Ship building Manufacturing, Power plants Pharmaceutical, food and beverages, water

More information

Manifold Technology.

Manifold Technology. ----------------------------------------------------- 2017.2 Manifod Technoogy. made in Germany I Epkg. unitrything UNDER CONTROL. Manifod Technoogy - I BEULCO heating and cooing manifods made of high-quaity

More information

Rule No. 16 SERVICE CONNECTIONS, METERS, AND CUSTOMER S FACILITIES

Rule No. 16 SERVICE CONNECTIONS, METERS, AND CUSTOMER S FACILITIES SOUTHERN CALIFORNIA WATER COMPANY Revised Ca. P.U.C. Sheet No. 3450-W SAN DIMAS, CALIFORNIA 91773-9016 Canceing Revised Ca. P.U.C. Sheet No. 3293-W Page 1 of 7 A. Genera 1. Utiity s Responsibiity a. (1)

More information

Innovation. Simplicity. is Simply Better. Rotary Lobe Pumps

Innovation. Simplicity. is Simply Better. Rotary Lobe Pumps Innovation Simpicity is Simpy Better Rotary Lobe Pumps So simpe, yet so diverse. Pease add. Six series with 19 sizes. AL-series PL-series CL-series FL-series EL-series XL-series A pump modes are manufactured

More information

MarCator 1087 ABS USB. No interface box is required! Simple and inexpensive way to set up a multiple measuring. Digimatic. evaluation instrument

MarCator 1087 ABS USB. No interface box is required! Simple and inexpensive way to set up a multiple measuring. Digimatic. evaluation instrument - -46 MarCator 1087 The new Digita Indicator Marcator 1087. The muti-functiona Digita Indicator with a combined anaog and digita dispay; pus toerance and dynamic measuring functions. D y n a m i c m e

More information

STEPPER DRIVE : E-5042

STEPPER DRIVE : E-5042 54, Annapurna Industria Estate, Tiak oad, E L E C T O N I C S Introduction The E-5042 is a fuy digita stepper drive deveoped with advanced DSP contro agorithm based on the atest motion contro technoogy.

More information

Aluminium Fixed Blade Return Grilles Series

Aluminium Fixed Blade Return Grilles Series Auminium Fixed Bade Return Gries 4900 Series Auminium Fixed Bade Return Gries Modes 5145H and 51FH Return Gries have fixed horizonta bades (parae to width/first specified dim.) spaced on 19mm centres with

More information

EH Range Technical Data

EH Range Technical Data EH Range Technica Data Eectro-hydrauic Vave Actuators Redefining Fow Contro EH Range Technica Data INTRODUCTION The Rotork EH Range of sef-contained, eectro-hydrauic actuator incudes an integrated contro

More information

TANK - S ELECTRICAL SYSTEM

TANK - S ELECTRICAL SYSTEM TANK - S ELECTRICAL SYSTEM Mode Year 2009 TANK - S ELECTRICAL SYSTEM TABLE OF CONTENTS: PAGE 3 ) PIMARY WIRE COLOR DESIGNATION: Red. Green. Orange. Yeow. Bue. PRIMARY COMPONENTS: Battery. Fuses. Seat Switch.

More information

EP Series WPS150S. Generator Set Specification. Super Quiet, Superior Life! Page of 5

EP Series WPS150S. Generator Set Specification. Super Quiet, Superior Life! Page of 5 EP Series Generator Set Specification Super Quiet, Superior Life! Page - 1 - of 5 3-Phase, 50Hz@1500RPM Prime Power Standby Power Votage kw kva Amps 380 120 150 227.9 400 120 150 216.5 415 120 150 208.7

More information

OPTISWITCH 5300 C. Handbook. Vibrating Level Switch. - transistor (NPN/PNP)

OPTISWITCH 5300 C. Handbook. Vibrating Level Switch. - transistor (NPN/PNP) OPTISWITCH 5300 C Handbook Vibrating Level Switch - transistor (NPN/PNP) 2 Contents Contents 1 About this document 1.1 Function... 3 1.2 Target group... 3 1.3 Symbols used... 3 2 For your safety 2.1 Authorised

More information

1

1 www.systems-sunight.com 1 2 www.systems-sunight.com SUNLIGHT s motive power (traction) batteries motivate your business, as they provide reiabe energy to your industria vehices every day. SUNLIGHT s speciaized

More information

User Manual. 12 Volt Battery Charger THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS READ ENTIRE INSTRUCTION BEFORE USE

User Manual. 12 Volt Battery Charger THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS READ ENTIRE INSTRUCTION BEFORE USE User Manua 12 Vot Battery Charger Pus Battery maintainer and Rejuvenator THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS READ ENTIRE INSTRUCTION BEFORE USE Mode No. 60134 / 60138 1 WARNING

More information

Model TWS. Swirl Diffusers

Model TWS. Swirl Diffusers Mode TWS Swir Diffusers Mode TWS Advanced Air s new range of high performance TWS ceiing swir diffusers have been designed to deiver the high air change rates required to meet the demand of high oads.

More information

OPTISWITCH 5300 C. Handbook. Vibrating Level Switch. - transistor (NPN/PNP) With SIL qualification

OPTISWITCH 5300 C. Handbook. Vibrating Level Switch. - transistor (NPN/PNP) With SIL qualification OPTISWITCH 5300 C Handbook Vibrating Level Switch - transistor (NPN/PNP) With SIL qualification 2 Contents Contents 1 About this document 1.1 Function... 3 1.2 Target group... 3 1.3 Symbols used... 3 2

More information

Air nozzles. Air curtains Blowing off and out Cleaning Cooling Drying Reheating Transporting and many others...

Air nozzles. Air curtains Blowing off and out Cleaning Cooling Drying Reheating Transporting and many others... Air nozzes Air curtains Bowing off and out Ceaning Cooing Drying Reheating Transporting and many others Air nozzes As a rue, any fat fan or soid stream nozze can be operated with air instead of iquid However,

More information

Operating Instructions 07/2017

Operating Instructions 07/2017 Vibrating Switches SITRANS LVL200H Transistor (NPN/PNP) Operating Instructions 07/2017 2 SITRANS LVL200H - Operating Instructions Contents 1 About this document 1.1 Function... 5 1.2 Target group... 5

More information

INSTRUCTION MANUAL LITHIUM-ION POLYMER MINI JUMP STARTER (KIT SET) SC POWER SCB22

INSTRUCTION MANUAL LITHIUM-ION POLYMER MINI JUMP STARTER (KIT SET) SC POWER SCB22 INSTRUCTION MANUAL LITHIUM-ION POLYMER MINI JUMP STARTER (KIT SET) Technica Specifications SCB22 Battery Type: Lithium-Ion Poymer Battery Capacity: 2200 mah (12V DC) Crancking Ampere: 220 A Peak Current:

More information

Ready for the future. ST 1082 mobile column lifts capacity kg

Ready for the future. ST 1082 mobile column lifts capacity kg Ready for the future ST 1082 mobie coumn ifts capacity 8.200 kg Two hard and fast aws appy in today s maintenance and repair faciities: time is money and an agreement is an agreement. This is why more

More information

1B20 1B30 1B40. The engineering result of careful market research: Small, light, powerful and universally applicable kw HP.

1B20 1B30 1B40. The engineering result of careful market research: Small, light, powerful and universally applicable kw HP. The engineering resut of carefu market research: Sma, ight, powerfu and universay appicabe Te: 0 85 3 / 39-0 Fax: 3 94 8 http://www.hatz-diese.de emai: marketing@hatz-diese.de.4-7.7 kw.8-0.5 HP 5 / 629

More information

Linear Slot Diffusers Series

Linear Slot Diffusers Series Linear Sot iffusers 5000 Series Linear Sot iffusers 5000 Series The Series 5000 Linear Sot Ceiing iffuser has been speciay designed to provide both the unobtrusive appearance required for architectura

More information

INSTALLATION AND MAINTENANCE MANUAL for ST400-C339 SOLENOID VALVE

INSTALLATION AND MAINTENANCE MANUAL for ST400-C339 SOLENOID VALVE 04666358 Edition 2 February, 1999 INSTALLATION AND MAINTENANCE MANUAL for ST400-C339 SOLENOID VALVE. IMPORTANT SAFETY INFORMATION ENCLOSED. READ THIS MANUAL BEFORE OPERATING VALVE. IT IS THE RESPONSIBILITY

More information

Components for. Overhead Cranes. Sta dard n. Engineered. Hoists. Endtrucks. Crane Kits. Engineered Material Handling

Components for. Overhead Cranes. Sta dard n. Engineered. Hoists. Endtrucks. Crane Kits. Engineered Material Handling Engineered Materia Handing Components for Overhead Cranes Sta dard n Hoists Engineered Hoists Endtrucks Crane Kits Troey drive consists of singe speed squirre-cage gear motors. Integra disc brakes are

More information

Operating instructions CI24RP.. CI30RP..

Operating instructions CI24RP.. CI30RP.. Operating instructions en CI24RP.. CI30RP.. Tabe of Contents Congratuations.................................................................................. 3 Safety and warning information......................................................................

More information

Fenix TK65R Flashlight

Fenix TK65R Flashlight BrightGuy.com is an authorized Fenix Distributor Fenix TK65R Fashight 1. Cataput action bet cip 2. Quick-reease button Technica Parameters ANSI/PLATO Genera Mode Fash Mode FL1 Turbo High Med Low Eco Strobe

More information

Interact Overhead Power

Interact Overhead Power Interact Overhead Power 75 range introduction feature benefits Interact Overhead Power System is a powertrack catering for singe, 3 phase or dua circuit appications suitabe for standard, permanent ive,

More information

Our policy is one of continuous research and development. We therefore reserve the right

Our policy is one of continuous research and development. We therefore reserve the right Tubing & Hose Metric Nyon, Poyurethane, Poyester Reinforced PVC, Meta Braided Rubber, Copper, Doube Wa Brazed Stee Avaiabe in a variety of different types to suit a wide range of appications A tubing can

More information

Prestolok. Spark resistant push-in fittings for fluids. Catalogue /UK

Prestolok. Spark resistant push-in fittings for fluids. Catalogue /UK Spark resistant push-in fittings for fuids Cataogue 352-/UK Cataogue 352-/UK Index Straight connectors Mae - BSPT Mae - Metric Mae - BSPT Mae - NPTF F23PB - p. C F2PB - p. C F3PB - p. C FPB - p. C Mae

More information

n Section for connecting rigid or flexible conductors (with Starfix ferrules) Distribution Blocks Four pole Equipped with 4 bars

n Section for connecting rigid or flexible conductors (with Starfix ferrules) Distribution Blocks Four pole Equipped with 4 bars www.kinkmann.com moduar distribution bocks 40 to 0 moduar distribution bocks 40 to 0 048 76 + 048 46 048 77 Technica characteristics (p. 2) Standard distribution Connection with or without Starfix ferrues

More information

Flexible Electric Cables for Mining Applications

Flexible Electric Cables for Mining Applications Fexibe Eectric Cabes for Mining Appications Fexibe Eectric Cabes Cataog BU IS 2.3 2000 Fexibe Eectric Cabes for Mining Appications 1 Genera Detais 2 Seection of Cabes 3 Cabe Accessories 4 Tabes/Expanations

More information

Lintra-Lite Actuators Series A44000, Rodless Cylinders Double Acting

Lintra-Lite Actuators Series A44000, Rodless Cylinders Double Acting Section 11 Lintra-Lite Actuators Series A44000, Rodess Cyinders Doube Acting LINTRA -LITE Series A44000 Rodess Cyinders Series A44000 Features...ACT-11-2 Series A44000 Specifications...ACT-11-3 Series

More information

TD3 Series UNIQUE LIGHTING SOLUTIONS RETROFIT INSTALLATION GUIDE TD3-1-UN-65 TD3-3-UN-65

TD3 Series UNIQUE LIGHTING SOLUTIONS RETROFIT INSTALLATION GUIDE TD3-1-UN-65 TD3-3-UN-65 TD3-1-UN-65 TD3-3-UN-65 RETROFIT INSTALLATION GUIDE UNIQUE LIGHTING SOLUTIONS WARNING Retrofit instaation must ony be performed by a icensed eectrician. To prevent death, injury or damage to property this

More information

MarCator 1087 R ABS. Just set once to zero. Battery service life is 3 years. Error free operation

MarCator 1087 R ABS. Just set once to zero. Battery service life is 3 years. Error free operation - -6 MarCator 1087 R The new Digita Indicator MarCator 1087 R. The muti-functiona Digita Indicator with a combined anaog and digita dispay as we as toerance and dynamic measuring functions. Dynamic measuring

More information

SP Stationary concrete pump. Concrete output max. 113 m³/h Concrete output max. 162 bar. 18,300-19,400 lb

SP Stationary concrete pump. Concrete output max. 113 m³/h Concrete output max. 162 bar. 18,300-19,400 lb SP 38 Stationary pump Concrete output max. 113 m³/h Concrete output max. bar Concrete output - 24 kw Machine weight 8,3-8,8 kg 18,3-19,4 b The SP 38 from SCHWING Performance and reiabiity SP 38 Stationary

More information

Displacement from 43 to 150 ccm Pressure up to 280 bar Speed from 250 to 3200 RPM GEAR PUMPS QHD2

Displacement from 43 to 150 ccm Pressure up to 280 bar Speed from 250 to 3200 RPM GEAR PUMPS QHD2 Dispacement from 43 to 150 ccm Pressure up to 280 bar Speed from 250 to 3200 PM GEA PUMPS QHD2 Gear Pump Cataogue QHD2 TABE OF CONTENTS BASIC DESCIPTION.............................................................................................................

More information

GEAR PUMPS. Displacement from 7 to 51 ccm Pressure up to 260 bar QHD0. Speed from 350 to 3400 RPM

GEAR PUMPS. Displacement from 7 to 51 ccm Pressure up to 260 bar QHD0. Speed from 350 to 3400 RPM GEA PUMPS Dispacement from 7 to 51 ccm Pressure up to 260 bar QHD0 Speed from 350 to 3400 PM Gear Pump Cataogue QHD0 TABE OF CONTENTS DESCIPTION......................................................................................................................

More information

USER INSTRUCTIONS USER INSTRUCTIONS. Innovative Car Alarm. Thatcham M.I.R.R.C. Evaluation No: TC2-1065/0199

USER INSTRUCTIONS USER INSTRUCTIONS. Innovative Car Alarm. Thatcham M.I.R.R.C. Evaluation No: TC2-1065/0199 USER INSTRUCTIONS USER INSTRUCTIONS Innovative Car Aarm Thatcham M.I.R.R.C. Evauation No: TC2-1065/0199 IMPORTANT WARNING The Cobra 7928/26/HF Aarm Immobiiser is a Category 1 MIRRC Thatcham isted security

More information

Level Switches. Features and Benefits. Request Quote

Level Switches. Features and Benefits. Request Quote SEE MORE AT SORInc.com Request Quote Leve Switches SOR mechanica eve switches are rugged, industria products specificay designed for versatiity of appication. This cataog contains appication and ordering

More information

Level Measurement Point level measurement - Vibrating switches

Level Measurement Point level measurement - Vibrating switches Overview Configuration Horizontal mounting (recommended mounting position, particularly for adhesive applications) Vertical mounting is a compact vibrating level switch for material detection in liquid

More information

solenoid dosing pumps

solenoid dosing pumps teknaevo soenoid dosing pumps innovation > technoogy > future The evoution of soenoid dosing pumps Cever Just Modes, Just PVDF, A functions in one pump modes that cover 1 to 60 t/h with an output pressure

More information

Displacement from 10 to 100 ccm Pressure up to 300 bar Speed from 300 to 3200 RPM GEAR PUMPS QHD1

Displacement from 10 to 100 ccm Pressure up to 300 bar Speed from 300 to 3200 RPM GEAR PUMPS QHD1 Dispacement from 10 to 100 ccm Pressure up to 300 bar Speed from 300 to 3200 PM GEA PUMPS QHD1 Gear Pump Cataogue QHD1 TABE OF CONTENTS DESCIPTION......................................................................................................................

More information

30 Electric ding. IMPORTANT: Read and save these instructions. ALL RANGES CAN TIP INJURY TO PERSONS COULD RESULT SEE INSTALLATION INSTRUCTIONS

30 Electric ding. IMPORTANT: Read and save these instructions. ALL RANGES CAN TIP INJURY TO PERSONS COULD RESULT SEE INSTALLATION INSTRUCTIONS Part No. 9752387 ALL RANGES CAN TIP INJURY TO PERSONS COULD RESULT INSTALL ANTI-TIP DEVICE PACKED WITH RANGE SEE INSTALLATION INSTRUCTIONS 30 Eectric ding IMPORTANT: Read and save these instructions. IMPORTANT:

More information

VS235XR / VS255XR. Rechargeable backup battery capability 3-channel transmitter With rolling code & code learning technology. STANDARD FEATURES l

VS235XR / VS255XR. Rechargeable backup battery capability 3-channel transmitter With rolling code & code learning technology. STANDARD FEATURES l VS235XR / VS255XR Sef-Contained, RF Remote-Controed Vehice Security System Rechargeabe backup battery capabiity 3-channe transmitter With roing code & code earning technoogy CBA STANDARD FEATURES RF Remote

More information

ABOVE GROUND TANKS 66 WATER DIVISION ROTOTEC

ABOVE GROUND TANKS 66 WATER DIVISION ROTOTEC OVE GROUND TNKS 66 WTER DIVISION ROTOTEC WTER DIVISION ROTOTEC 67 VERTICLE From 50 to 10000 itres Instaation Paced directy on a fat supporting surface vaiabe coours: standard on request Ø Cover Inet Outet

More information

ABB Measurement & Analytics. Valve positioners For marine applications

ABB Measurement & Analytics. Valve positioners For marine applications ABB Measurement & Anaytics Vave positioners For marine appications 2 VALVe positioners For marine appications Vave positioners For the marine industry ABB s industry proven EDP300 and TZIDC positioners

More information

Operating Instructions VEGASWING 66. Vibrating level switch for liquids under extreme process temperatures and pressures

Operating Instructions VEGASWING 66. Vibrating level switch for liquids under extreme process temperatures and pressures Operating Instructions Vibrating level switch for liquids under extreme process temperatures and pressures VEGASWING 66 Transistor (NPN/PNP) With SIL qualification Document ID: 44951 2 Contents Contents

More information

How to Order. Auto switch. Without auto switch (Built-in magnet) Applicable Auto Switches/Refer to p for further details. Indicator.

How to Order. Auto switch. Without auto switch (Built-in magnet) Applicable Auto Switches/Refer to p for further details. Indicator. Compact Side Series MXU How to Order MXU A90V S Compact side Bore size 1 ø ø ø1 1 2 Stroke mm mm 1mm mm 2mm mm Number of auto switches 2 Auto switch S 1 Without auto switch (Buit-in magnet) Appicabe Auto

More information

N1VS VARIABLE SPEED AIR HANDLERS

N1VS VARIABLE SPEED AIR HANDLERS (0500) TECHNICAL SPECIFICATIONS VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING AND HEAT PUMP 600-2000 CFM BLOWERS 2-5 TON COILS OPTIONAL1 & 3 Ø ELECTRIC HEATERS DESCRIPTION These variabe

More information

LASER & LOW BODY Fan Coil Units

LASER & LOW BODY Fan Coil Units LASER & LOW BODY Fan Coi Units 2 & 4 pipe system A compete range from 0.6 kw up to 9.7 kw TUC03 Termina unit controer BacNET and N2 Metasys network compatibe CSL00 (Buit in) CSR00 (Wa mounted) Fan speed

More information

Level Limit Switch liquiphant FTL 365 / FTL 366

Level Limit Switch liquiphant FTL 365 / FTL 366 Technical Information TI 86F/00/en Level Limit Switch liquiphant FTL 65 / FTL 66 Level limit switch Liquiphant II with vibrating probe. For all types of liquid. With explosionproof housing for use in hazardous

More information

TK35UE 2018 Flashlight

TK35UE 2018 Flashlight TK35UE 2018 Fashight Technica Parameters ANSI/PLATO FL1 Genera Mode Fash Mode Turbo High Med Low Eco Strobe SOS Output Tactica Mode Outdoor Mode 3200 2000 1000 350 100 20 3200 100 1h 30min 2h 3h 40min

More information

ULTRAFLEX UC 128-SVS. Installation and Maintenance manual HYDRAULIC CYLINDER FOR OUTBOARD ENGINES. page 2 pag. 19 page 37 PARTNER

ULTRAFLEX UC 128-SVS. Installation and Maintenance manual HYDRAULIC CYLINDER FOR OUTBOARD ENGINES. page 2 pag. 19 page 37 PARTNER Instaation and Maintenance manua HYDRAULIC CYLINDER FOR OUTBOARD ENGINES UC 128-SVS FRANÇAIS ITALIANO R UK I page 2 pag. 19 page 37 F PARTNER (Dr. No. 25713/a 09/03/2015) Dear Customer, We woud ike to

More information

Level instruments. Point level measurement - Vibrating switches SITRANS LVL100. 5/78 Siemens FI Horizontal mounting.

Level instruments. Point level measurement - Vibrating switches SITRANS LVL100. 5/78 Siemens FI Horizontal mounting. evel instruments Siemens AG 2009 Overview Configuration Horizontal mounting (recommended mounting position, particularly for adhesive applications) Vertical mounting with lower density is a compact vibrating

More information

Flat fan nozzles. Nozzle characteristics

Flat fan nozzles. Nozzle characteristics Fat fan nozzes Bet ceaning Coating Steam ceaning Degreasing High pressure ceaning Grave washing Cooing Surface treatment Phosphating Rain curtains Foam contro Foam spraying Lubrication Fiter ceaning ceaning

More information

Blind Rivet Nuts indispensable part modern installation engeneering nearly unlimited fields of applications Honsel-Group

Blind Rivet Nuts indispensable part modern installation engeneering nearly unlimited fields of applications Honsel-Group Bind Rivet Nuts Bind rivet nuts have become an indispensabe part modern instaation engeneering. They aow to insta bot threads of different types into...... thin or ow rigidity components... hoow sections

More information

/1505-I-20 TOO L HO L DERS 2015 GM 300

/1505-I-20 TOO L HO L DERS 2015 GM 300 TO O L H O L D ERS A N D C L A M PI N G D E V I C ES 114 996/1505-I-20 ED I T I O N 2015 TOO L HO L DERS 2015 GM 300 high camping ce PERFECT CONCENTRICITY MAXIMUM OPERATIONAL SAFETY OPTIMAL COOLANT DELIVERY

More information

A Product of Hard Work SELECTOR GRABS

A Product of Hard Work SELECTOR GRABS A Product of Hard Work SELECTOR GRABS ATTACHMENTS SELECTOR GRABS The perfect partner for your machine Simpe heavy duty design for maximum durabiity and reiabiity Buit in safety features to protect the

More information

ASSEMBLY AND INSTALLATION

ASSEMBLY AND INSTALLATION ASSEMBY AND INSTAATION STRAIGT AND EVE GUARDRAIING (using Tpes 10, 15, 20, 21, 25 & 26) Where: = distance between centres of uprights I = ength of horizonta tube = distance from ground to centre ine of

More information

LASER & LOW BODY Fan Coil Units 2 & 4 pipe system A complete range from 0.7 kw up to 9.5 kw

LASER & LOW BODY Fan Coil Units 2 & 4 pipe system A complete range from 0.7 kw up to 9.5 kw york air-conditioning products LASER & LOW BODY Fan Coi Units 2 & 4 pipe system A compete range from 0.7 kw up to 9.5 kw CSL00 (Buit in) CSR00 (Wa mounted) Fan speed seector CML00 (Buit in) CMR00 (Wa mounted)

More information

Procyon 1. Product # Type Date Project Name Project Location Prepared By. Construction. Optical System. Product Applications. l l l. l l l.

Procyon 1. Product # Type Date Project Name Project Location Prepared By. Construction. Optical System. Product Applications. l l l. l l l. Product # Type Date Project Name Project Location Prepared By Construction Housing is ow copper die-cast auminum, heavy duty, structuray rigid and vibranty dissipating heat for onger umen maintenance ife-hours.

More information

Piston pumps for eff icient wellpoint dewatering

Piston pumps for eff icient wellpoint dewatering Piston pumps for eff icient wepoint dewatering PT series P u m p s f o r r e s u t s Innovative eaders for the past 60 years BBA Pumps BV woudn t be a Dutch company if it didn t know how to dea with water!

More information

Displacement from 9 to 31 ccm Pressure up to 280 bar Speed from 500 to 3000 RPM GEAR PUMPS T3S

Displacement from 9 to 31 ccm Pressure up to 280 bar Speed from 500 to 3000 RPM GEAR PUMPS T3S Dispacement from 9 to 31 ccm Pressure up to 280 bar Speed from 500 to 3000 PM GEA PUMPS T3S Gear Pump Cataogue T3S TABE OF CONTENTS DESCIPTION......................................................................................................................

More information

Operating instructions Maintenance instructions

Operating instructions Maintenance instructions Operating instructions Maintenance instructions Origina operating instructions S/N 101 692 26 1434 > / S/N 101 692 35... Reversibe Vibrating Pate Cataogue No. 008 067 61 12/2012 Foreword 1 Foreword BOMAG

More information

Level Limit Switch liquiphant FTL 360 / FTL 361

Level Limit Switch liquiphant FTL 360 / FTL 361 Technical Information TI 184F/00/en evel imit Switch liquiphant FT 360 / FT 361 evel limit switch iquiphant II with vibrating probe. For all types of liquid. iquiphant level limit switch: FT 360, compact

More information

Any switch configuration

Any switch configuration Series L2 Rotary Cam es Attractive design, reiabe operation and high quaity for any appication up to 25 Amps TIP! Sprecher + Schuh s comprehensive ine of L2 rotary cam switches are avaiabe for a contro

More information

S.B. 469 for information on GM applications). Both styles are shown in Figure 1. Figure 1

S.B. 469 for information on GM applications). Both styles are shown in Figure 1. Figure 1 NO: 4263132 SERVICE BULLETIN DATE: January X,1993 Supersedes: S.B. 426R dated 11/7/89 SUBJECT: ZERO-CLEARAN CE GOVERNOR WEIGHT RETAINER ASSEMBLIES In June 1988, Stanadyne introduced a zero-cearance Eastomer

More information

GEAR PUMPS. Displacement from 10 to 36 ccm Pressure up to 300 bar GHD0. Speed from 350 to 3400 RPM

GEAR PUMPS. Displacement from 10 to 36 ccm Pressure up to 300 bar GHD0. Speed from 350 to 3400 RPM GEA PUMPS Dispacement from 10 to 36 ccm Pressure up to 300 bar GHD0 Speed from 350 to 3400 PM Gear Pump Cataogue GHD0 TABE OF CONTENTS DESCIPTION......................................................................................................................

More information

<AN002.doc> DALF Application Note #002. Dalf/Simple-H Hookup. Revision 0.02 May 04, 2007

<AN002.doc> DALF Application Note #002. Dalf/Simple-H Hookup. Revision 0.02 May 04, 2007 DALF Appication Note #002 Daf/Simpe-H Hookup Revision 0.02 May 04, 2007 Embedded Eectronics Page 1 5/4/2007 Tabe of Contents 1 APPLICATION NOTE SYNOPSIS...2 2 HOOKUP...2 3 PICTURE (DURING TEST)...3

More information

Operating instructions Maintenance instructions

Operating instructions Maintenance instructions Operating instructions Maintenance instructions Origina operating instructions BPR 45/55 D - BPR 55/65 D S/N 101 692 14... / S/N 101 692 33... / S/N 101 692 16... / S/N 101 692 34... Reversibe Vibrating

More information

MHL 335 MHL 335 MATERIAL HANDLER

MHL 335 MHL 335 MATERIAL HANDLER MHL 335 MATERIAL HANDLER ENGINE WEIGHT REACH 153 HP (114 kw) 51,808-55,115 bs (23.5-25 t) 39.4' (12 m) 36' (11 m) 35' (10.7 m) High-performance 153 HP (114 kw) turbocharged diese engine (TIER III/COM III)

More information

Level detection in liquids. Vibration VEGASWING 51 VEGASWING 61 VEGASWING 63. Product Information

Level detection in liquids. Vibration VEGASWING 51 VEGASWING 61 VEGASWING 63. Product Information Level detection in liquids Vibration VEGASWING 5 VEGASWING 6 VEGASWING 6 Product Information Contents Contents Description of the measuring principle...........................................................

More information

TECHNICAL DATA AND INFORMATION. 366 hp. 145, ,710 lbs. up to 68.9 ft SCRAP-HANDLING AND PORT MACHINE MHL380D

TECHNICAL DATA AND INFORMATION. 366 hp. 145, ,710 lbs. up to 68.9 ft SCRAP-HANDLING AND PORT MACHINE MHL380D TECHNICAL DATA AND INFORMATION 366 hp 145,505-147,7 bs up to 68.9 ft MHL380D SCRAP-HANDLING AND PORT MACHINE TECHNICAL DATA MHL380 D OPERATING WEIGHT 145,505-147,7 bs DIESEL ENGINE MANUFACTURER AND MODEL

More information

FSM Electrical heating cable for frost protection or temperature maintenance of instrument lines and pipework in safe or hazardous locations

FSM Electrical heating cable for frost protection or temperature maintenance of instrument lines and pipework in safe or hazardous locations FSM Eectrica heating cabe for frost protection or temperature maintenance of instrument ines and pipework in safe or hazardous ocations FREEZSTOP MICRO Sef-Reguating Heating Tape Automaticay adjusts heat

More information

600 kva, 600 kw Installation and Operation Manual

600 kva, 600 kw Installation and Operation Manual Eaton Power Xpert 9395 High Performance (9395P-600) UPS 600 kva, 600 kw Instaation and Operation Manua For use with Singe UPM (200 600 kva), Two UPM (400 600 kva), and Pus 1 (400 600 kva) UPS Modes Eaton

More information

Filter Return Grilles. 51F Series Aluminium

Filter Return Grilles. 51F Series Aluminium Fiter Return Gries 51F Series uminium Fiter Return Gries 51F Series uminium The dvanced ir Mode Series 51F Fiter Return Gries are a convenient and economica means of fitering primary return air ocay. They

More information

AVOLA KREISSÄGEN. Revolving Cross Cut Saw GAMA 65 K. Technical Equipment. Options

AVOLA KREISSÄGEN. Revolving Cross Cut Saw GAMA 65 K. Technical Equipment. Options AVOLA Revoving Cross Cut Saw GAMA 65 K Technica Equipment Motor rating 8,1 kw/400 Vac-50 Hz, star / deta start sawbade mounted direct on motor shaft Motor speed 3.000 rpm / sawbade speed 3.000 rpm Sawbade

More information

PRECISION PUMP APPLICATOR

PRECISION PUMP APPLICATOR User s Manua nstaation & Operating nstructions PRECSON PUMP APPLCATOR For Box, Junior, and Custom Appicators For questions and/or product support contact the TW ROCOL North America Customer Service Department

More information