Characteristics TeSys contactors 0 Model d

Size: px
Start display at page:

Download "Characteristics TeSys contactors 0 Model d"

Transcription

1 Charateristis TeSys ontators 0 Model d Contator type LC1 D09 D18 D25 D38 D40 D50 D95 D115 and D150 DT20 and DT25 DT32 and DT40 Environment Rated insulation voltage (Ui) Conforming to IEC , V overvoltage ategory III, degree of pollution: 3 Conforming to UL, CSA V 600 Rated impulse withstand voltage (Uimp) Conforming to IEC kv 6 8 Conforming to standards IEC , , NFC , VDE 0660, BS 24, JEM EN , EN GL, DNV, PTB, RINA pending Produt ertifiations UL, CSA Complies with SNCF, Sihere Trennung reommendations Separation insulation Conforming to VDE 0106 part 101 and (draft 2/89) V 400 Degree of protetion (1) (front fae only) Conforming to VDE 0106 Power onnetion Coil onnetion Protetion against diret finger ontat IP 2X Protetion against diret finger ontat IP 2X Protetive treatment Conforming to IEC TH Ambient air temperature around the devie Storage C Operation C Permissible C , for operation at U Maximum operating altitude Without derating m 3000 Operating positions (2) Without derating in the following positions a/ a Positions that are not permissible For ontators LC1 D09 to D38 Flame resistane Conforming to UL 94 V1 Conforming to IEC C 960 Shok resistane (3) 1/2 sine wave = 11 ms Vibration resistane (3) Hz Contator open 10 gn 8 gn 8 gn 8 gn 6 gn Contator losed 15 gn 15 gn 10 gn 10 gn 15 gn Contator open 2 gn Contator losed 4 gn 4 gn 4 gn 3 gn 4 gn (1) Protetion provided for the abling.s.a.'s indiated on the next page and for onnetion by able. (2) For other operating positions, please onsult your Regional Sales Offie. (3) Without hange of ontat states, in the most unfavourable diretion (oil energised at Ue). Seletion : Referenes : pages 24501/2 to 24502/3 Dimensions : pages 24531/2 to 24531/5 Shemes : pages 24532/2 and 24532/ EN_Ver9.0.fm/2

2 Charateristis (ontinued) TeSys ontators 0 Model d Contator type LC1 D09 and D12 DT20 and DT25 D18 (3P) D25 (3P) D32 D38 D18 and D25 (4P) DT32 and DT40 Power iruit onnetions Connetion by able Tightening torque Srew lamp terminals Connetor 2 inputs Flexible able without able end Flexible able with able end Solid able without able end D40 Srew lamp terminals D50 and D65 Connetor 1 input D80 and D95 D115 and D150 Connetor 2 inputs 1 ondutor mm ondutors mm ondutor mm ondutors mm ondutor mm ondutors mm Srewdriver Philips N 2 N 2 N 2 N 2 N 2 Flat srewdriver Ø Ø 6 Ø 6 Ø 6 Ø 6 Ø 6 Ø 6 Ø 8 Ø 6 Ø 8 Ø 6 Ø 8 Key for hexagonal headed srew 4 4 Tightening torque N.m Spring terminal onnetions (1) Flexible able without able end 1 ondutor mm (4: DT25) 2 ondutors mm (exept DT25) Connetion by bars or lugs Bar ross-setion 3 x 16 5 x 25 Lug external Ø mm (2) Ø of srew mm M3.5 M3.5 M4 M4 M3.5 M5 M6 M6 M8 Srewdriver Philips N 2 N 2 N 2 N 2 N 2 N 2 N 3 Flat srewdriver Ø Ø 6 Ø 6 Ø 6 Ø 6 Ø 6 Ø 8 Ø 8 Ø 8 Key for hexagonal headed srew Tightening torque N.m Control iruit onnetions Connetion via able (tightening via srew lamps) Flexible able without able end Flexible able with able end Solid able without able end 1 ondutor mm ondutors mm ondutor mm ondutors mm ondutor mm ondutors mm Srewdriver Philips N 2 N 2 N 2 N 2 N 2 N 2 N 2 N 2 N 2 Flat srewdriver Ø Ø 6 Ø 6 Ø 6 Ø 6 Ø 6 Ø 6 Ø 6 Ø 6 Ø 6 Tightening torque N.m Spring terminal onnetions (1) Flexible able 1 ondutor mm without able end 2 ondutors mm Connetion by bars or lugs Lug external Ø mm Ø of srew mm M3.5 M3.5 M3.5 M3.5 M3.5 M3.5 M3.5 M3.5 M3.5 Srewdriver Philips N 2 N 2 N 2 N 2 N 2 N 2 N 2 N 2 N 2 Flat srewdriver Ø Ø 6 Ø 6 Ø 6 Ø 6 Ø 6 Ø 6 Ø 6 Ø 6 Ø 6 Tightening torque N.m (1) If able ends are used, hoose the next size down (example: for 2.5 mm 2, use 1.5 mm 2 ) and square rimp the able ends using a speial tool. (2) To onnet ables with a.s.a. > 4mm 2 and up to 10 mm 2, it is essential to use speial onnetors, sold in bags of 100 (referene: LAD 96180). Seletion : Referenes : pages 24501/2 to 24502/3 Dimensions : pages 24531/2 to 24531/5 Shemes : pages 24532/2 and 24532/ EN_Ver9.0.fm/3

3 Charateristis (ontinued) TeSys ontators 0 Model d Contator type LC1 D09 (3P) Pole harateristis Rated operational urrent (Ie) (Ue y 440 V) DT20 D098 D12 (3P) DT25 D128 D18 (3P) DT32 D188 In AC-3, θ y 60 C A In AC-1, θ y 60 C A 25 (1) (1) (1) (1) 40 Rated operational voltage (Ue) Up to V Frequeny limits Of the operating urrent Hz Conventional thermal urrent θ y 60 C A 25 (1) (1) (1) (1) 40 (Ith) Rated making apaity Conforming to IEC (440 V) Rated breaking apaity (440 V) Conforming to IEC Permissible short time rating No urrent flowing for preeding 15 minutes with θ y 40 C Protetion by fuses against short-iruits (U y 690 V) For 1 s A For 10 s A For 1 min A For 10 min A Without thermal overload relay, gg fuse type 1 A type 2 A With thermal overload relay A See pages 24514/2 and 24514/3, for am or gg fuse ratings orresponding to the assoiated thermal overload relay Average impedane per pole At Ith and 50 Hz mω Power dissipation per pole for the above operational urrents Control iruit harateristis, a.. supply AC-3 W AC-1 W Rated ontrol iruit voltage 50/60 Hz V (U) Control voltage limits 50 or 60 Hz oils Operational Drop-out 50/60 Hz oils Operational U on 50 Hz and U on 60 Hz at 60 C Drop-out U at 60 C Average onsumption at 20 C and at U a 50 Hz Inrush 50 Hz oil VA Cos ϕ /60 Hz oil VA 70 Sealed 50 Hz oil VA Cos ϕ /60 Hz oil VA 7 a 60 Hz Inrush 60 Hz oil VA Cos ϕ /60 Hz oil VA 70 Sealed 60 Hz oil VA Cos ϕ /60 Hz oil VA 7.5 Heat dissipation 50/60 Hz W 2 3 Operating time (2) Mehanial durability in millions of operating yles Closing "C" ms Opening "O" ms or 60 Hz oil 50/60 Hz oil on 50 Hz 15 D25 (3P) DT40 D258 Maximum operating rate at ambient temperature y 60 C In operating yles per hour 3600 (1) Versions with spring terminal onnetions: 16 A for LC1 D093 and LC1 D123 (20 A possible with 2 x 2.5 mm 2 ables in parallel), 25 A for LC1 D183 to LC1 D323 (32 A possible for LC1 D183 onneted with 2 x 4 mm2 ables in parallel; 40 A possible for LC1 D253 and LC1 D323 onneted with 2 x 4 mm2 ables in parallel). (2) The losing time "C" is measured from the moment the oil supply is swithed on to initial ontat of the main poles. The opening time "O" is measured from the moment the oil supply is swithed off to the moment the main poles separate. Seletion : Referenes : pages 24501/2 to 24502/3 Dimensions : pages 24531/2 to 24531/5 Shemes : pages 24532/2 and 24532/ EN_Ver9.0.fm/4

4 0 D32 D38 D40 D50 D65 D80 D95 D115 D (1) See pages 24514/2 and 24514/3, for am or gg fuse ratings orresponding to the assoiated thermal overload relay U at 55 C U at 55 C U at 55 C U at 55 C U on 50 Hz and U on 60 Hz at 60 C U on 50 Hz and U on 60 Hz at 55 C U on 50/60 Hz at 55 C U at 60 C U at 55 C U at 55 C EN_Ver9.0.fm/5

5 Charateristis (ontinued) TeSys ontators 0 Model d Contator type d.. ontrol iruit harateristis LC1 D09 D38 LC1 DT20 DT40 LC1 or LP1 D40 D65 LC1 or LP1 D80 LC1 D95 LC1 D115 and LC1 D150 Rated ontrol V iruit voltage (U) Rated insulation voltage Conforming to IEC V 690 Conforming to UL, CSA V 600 Control voltage limits Operational Standard oil Wide range oil Average onsumption at 20 C and at U Average operating time at U (1) U at 60 C U at 55 C U at 55 C U at 55 C Drop-out U at 60 C U at 55 C U at 55 C Inrush W to 365 Sealed W Closing "C" ms 63 ± 15 % Opening "O" ms 20 ± 20 % Note : The aring time depends on the iruit swithed by the poles. For all normal 3-phase appliations, the aring time is less than 10 ms. The load is isolated from the supply after a time equal to the sum of the opening time and the aring time. Time onstant L/R (L/R) ms Mehanial durability at U In millions of operating yles Maximum operating rate at ambient temperature y 60 C In operating yles per hour Low onsumption ontrol iruit harateristis Rated insulation voltage Conforming to IEC V 690 Conforming to UL, CSA V 600 Maximum voltage Of the ontrol iruit on 250 Average onsumption d.. at 20 C and at U Operating time (1) at U and at 20 C Wide range oil ( U) Inrush W 2.4 Sealed W 2.4 Closing "C" ms 77 ± 15 % Opening "O" ms 25 ± 20% Voltage limits (θ y 60 C) of the ontrol iruit Operational 0.7 to 1.25 U Drop-out U Time onstant L/R (L/R) ms 40 Mehanial durability In millions of operating yles 30 Maximum operating rate At ambient temperature y 60 C ops/h 3600 (1) The operating times depend on the type of ontator eletromagnet and its ontrol mode. The losing time "C" is measured from the moment the oil supply is swithed on to initial ontat of the main poles. The opening time "O" is measured from the moment the oil supply is swithed off to the moment the main poles separate. Seletion : Referenes : pages 24501/2 to 24502/3 Dimensions : pages 24531/2 to 24531/5 Shemes : pages 24532/2 and 24532/ EN_Ver9.0.fm/6

6 Charateristis (ontinued) TeSys ontators 0 Model d Charateristis of auxiliary ontats inorporated in the ontator Mehanially linked ontats Mirror ontat Conforming to IEC Conforming to IEC Rated operational voltage (Ue) Up to V 690 Rated insulation voltage (Ui) Conforming to IEC V 690 Conforming to UL, CSA V 600 Conventional thermal urrent (Ith) Frequeny of the operational urrent For ambient temperature y 60 C A 10 Eah ontator has 2 N/O and N/C ontats mehanially linked on the same movable ontat holder The N/C ontat on eah ontator represents the state of the power ontats and an be onneted to a PREVENTA safety module Hz Minimum swithing apaity U min V 17 λ = 10 8 I min ma 5 Short-iruit protetion Conforming to gg fuse: 10 A IEC Rated making apaity Conforming to IEC , I rms A a: 140, : 250 Short-time rating Permissible for 1 s A ms A ms A 140 Insulation resistane MΩ > 10 Non-overlap time Operational power of ontats onforming to IEC Guaranteed between N/C and N/O ontats ms 1.5 on energisation and on de-energisation a.. supply, ategories AC-14 and AC-15 d.. supply, ategory DC-13 Eletrial durability (valid for up to 3600 operating yles/hour) Eletrial durability (valid for up to 1200 operating yles/hour) on an indutive load suh as the oil of an eletromagnet: on an indutive load suh as the oil of an eletromagnet, making urrent (os ϕ 0.7) = 10 times the power broken without eonomy resistor, the time onstant inreasing with the (os ϕ 0.4). load. V V million operating yles VA W million operating yles VA W million operating yles VA W AC-15 DC-13 Millions of operating yles ,8 0,7 0,6 0,5 0,4 0,3 Millions of operating yles ,8 0,7 0,6 0,5 0,4 0,3 440 V 250 V 125 V 48 V 24 V 0,2 0,2 0,1 0,1 0,2 0,3 0,4 0,6 0, ,5 0,7 0, Current broken in A 0,1 0,1 0,2 0,3 0,4 0,6 0, ,5 0,7 0, Current broken in A Seletion : Referenes : pages 24501/2 to 24502/3 Dimensions : pages 24531/2 to 24531/5 Shemes : pages 24532/2 and 24532/ EN_Ver9.0.fm/7

7 Referenes TeSys ontators 3 For motor ontrol up to 75 kw at 400 V, in ategory AC-3 Control iruit: a.., d.. or low onsumption LC1 D09pp LC1 D25pp 3-pole ontators for onnetion by srew lamp terminals or onnetors Standard power ratings of 3-phase motors Hz in ategory AC-3 (θ y 60 C) 220 V 380 V 660 V 230 V 400 V 415 V 440 V 500 V 690 V 1000 V Rated operational urrent in AC V up to Instantaneous auxiliary ontats Basi referene, to be ompleted by adding the voltage ode (2) Fixing (1) Weight (3) kw kw kw kw kw kw A kg LC1 D09pp LC1 D12pp LC1 D18pp LC1 D25pp LC1 D32pp LC1 D38pp LC1 D40pp LC1 D50pp LC1 D65pp LC1 D80pp LC1 D95pp LC1 D115pp LC1 D150pp pole ontators for onnetion by lugs or bars In the referenes seleted above, insert a figure 6 before the voltage ode. Example: LC1 D09pp beomes LC1 D096pp Aessories Auxiliary ontat bloks and add-on modules: see pages 24511/2 to 24511/ LC1 D95pp LC1 D115pp (1) LC1 D09 to D38: lip-on mounting on 35 mm 5 rail AM1 DP or srew fixing. LC1 D40 to D95 a: lip-on mounting on 35 mm 5 rail AM1 DP or 75 mm 5 rail AM1 DL or srew fixing. LC1 D40 to D95 : lip-on mounting on 75 mm 5 rail AM1 DL or srew fixing. LC1 D115 and D150: lip-on mounting on 2 x 35 mm 5 rails AM1 DP or srew fixing. (2) Standard ontrol iruit voltages (for other voltages, please onsult your Regional Sales Offie): a.. supply Volts LC1 D09 D150 (D115 and D150 oils with integral suppression devie fitted as standard)) 50/60 Hz B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 LC1 D40 D Hz B5 D5 E5 F5 FE5 M5 P5 U5 Q5 V5 N5 R5 S5 60 Hz B6 E6 F6 M6 U6 Q6 R6 d.. supply Volts LC1 D09 D38 (oils with integral suppression devie fitted as standard) U U JD BD CD ED ND SD FD GD MD UD RD LC1 D40 D95 U U JD BD CD ED ND SD FD GD MD UD RD U U JW BW CW EW SW FW MW LC1 D115 and D150 (oils with integral suppression devie fitted as standard) U U BD ED ND SD FD GD MD UD RD Low onsumption Volts LC1 D09...D38 (oils with integral suppression devie fitted as standard) U U AL JL ZL BL EL FL ML UL For other voltages between 5 and 690 V, see pages 24507/2 to 24507/7. (3) The weights indiated are for ontators with a.. ontrol iruit. For d.. or low onsumption ontrol iruit, add kg for ontators LC1 D09 to D38, kg for ontators LC1 D40 to D65 and 1 kg for ontators LC1 D80 and D95. Seletion : Charateristis : pages 24505/2 to 24505/7 Dimensions : pages 24531/2 to 24531/5 Shemes : pages 24532/2 and 24532/ EN_Ver7.1.fm/2

8 Referenes TeSys ontators 0 a.. oils for 3 or 4-pole ontators LC1 D For ontators a LC1 D09...D38 and LC1 DT20 DT40 Speifiations Average onsumption at 20 C: - inrush (os = 0.75) 70 VA, - sealed (os = 0.3) 50 Hz: 7 VA, 60 Hz: 7.5 VA Operating range ( 60 C): 50 Hz: U, 60 Hz: U Control iruit voltage U Average resistane at 20 C ± 10 % Indutane of losed iruit Referene (1) Weight V H kg 50/60 Hz LXD 1J (2) LXD 1Z LXD 1B LXD 1C LXD 1pp 36 LXD 1CC LXD 1D LXD 1E LXD 1EE LXD 1K LXD 1F LXD 1FE LXD 1G LXD 1FC LXD 1L LXD 1LE LXD 1M LXD 1P LXD 1U LXD 1W LXD 1Q LXD 1V LXD 1N LXD 1R LXD 1T LXD 1S LXD 1SC LXD 1X LXD 1Y (1) The last 2 digits in the referene represent the voltage ode. (2) Voltage for speial oils fitted in ontators with serial timer modules. with 24 V supply EN_Ver6.0.fm/2

9 Referenes (ontinued) TeSys ontators 0 a.. oils for 3 or 4-pole ontators LC1 D For 3 or 4-pole ontators LC1 D40, D50, D65, D80, D95 Speifiations Average onsumption at 20 C: - inrush (os = 0.75) 50 Hz: 200 VA, 60 Hz: 220 VA, - sealed (os = 0.3) 50 Hz: 20 VA, 60 Hz: 22 VA Operating range ( 55 C): U LX1 D6pp Control iruit voltage U Average resistane at 20 C ±10% Indutane of losed iruit Referene (1) Average resistane at 20 C ±10% Indutane of losed iruit Referene (1) Weight V H H kg 50 Hz 60 Hz LX1 D6B LX1 D6B LX1 D6C LX1 D6D LX1 D6E LX1 D6E LX1 D6F LX1 D6F LX1 D6FE LX1 D6G LX1 D6G LX1 D6L LX1 D6M / LX1 D6M LX1 D6P LX1 D6U LX1 D6U LX1 D6W LX1 D6W LX1 D6Q / LX1 D6Q LX1 D6V LX1 D6N LX1 D6R LX1 D6R LX1 D6T LX1 D6S LX1 D6S LX1 D6X LX1 D6Y Speifiations Average onsumption at 20 C: - inrush (os = 0.75) 50/60 Hz: 245 VA at 50 Hz, - sealed (os = 0.3) 50/60 Hz: 26 VA at 50 Hz, Operating range ( 55 C): U. 50/60 Hz LX1 D6B LX1 D6D LX1 D6E LX1 D6F LX1 D6FE LX1 D6G /230 (2) LX1 D6M LX1 D6P /240 (3) LX1 D6U /400 (4) LX1 D6Q LX1 D6V LX1 D6N LX1 D6R (1) The last 2 digits in the referene represent the voltage ode. (2) For use on 230 V 50 Hz, apply a oeffiient of 0.6 to the mehanial durability of the ontator, see pages 24505/4 and 24505/5. This oil an be used on 240 V at 60 Hz. (3) This oil an be used on 220/240 V at 50 Hz and on 240 V only at 60 Hz. (4) For use on 400 V 50 Hz, apply a oeffiient of 0.6 to the mehanial durability of the ontator, see pages 24505/4 and 24505/ EN_Ver6.0.fm/3

10 Referenes (ontinued) TeSys ontators 0 a.. oils for 3 or 4-pole ontators LC1 D For 3 or 4-pole ontators LC1 D115 Speifiations Average onsumption at 20 C: - inrush (os = 0.8) 50 or 60 Hz: 300 VA, - sealed (os = 0.3) 50 or 60 Hz: 22 VA Operating range ( 55 C): U LX1 D8pp Control iruit voltage U Average resistane at 20 C ±10% Indutane of losed iruit Referene (1) Average resistane at 20 C ±10% Indutane of losed iruit Referene (1) Weight V H H kg 50 Hz 60 Hz LX1 D8B LX1 D8B LX1 D8C LX1 D8D LX1 D8E LX1 D8E LX1 D8F LX1 D8F LX1 D8FE LX1 D8G LX1 D8FC LX1 D8L LX1 D8M LX1 D8M LX1 D8P LX1 D8U LX1 D8U LX1 D8W LX1 D8Q LX1 D8Q LX1 D8V LX1 D8N LX1 D8R LX1 D8R LX1 D8T LX1 D8S For 3 or 4-pole ontators LC1 D115, LC1 D150 Speifiations Average onsumption at 20 C: - inrush os = to 350 VA, - sealed os = to 18 VA. Operating range ( 55 C): U. Coils with integral suppression devie fitted as standard, lass B. Control iruit voltage U Average resistane at 20 C ±10% Indutane of losed iruit Referene (1) Average resistane at 20 C ±10% Indutane of losed iruit Referene (1) Weight V H H kg 50/60 Hz LX1 D8B LX1 D8C LX1 D8D LX1 D8E LX1 D8F LX1 D8FE LX1 D8G LX1 D8FC LX1 D8LE LX1 D8M LX1 D8P LX1 D8U LX1 D8UE LX1 D8Q LX1 D8V LX1 D8N LX1 D8R LX1 D8T LX1 D8S (1) The last 2 digits in the referene represent the voltage ode EN_Ver6.0.fm/4

11 Referenes TeSys ontators 0 d.. oils for 3 or 4-pole ontators For 3-pole ontators LC1 D40 D65 or 4-pole ontators LP1 D40 D65 Speifiations Average onsumption: 22 W. Operating range: U Control iruit voltage U Average resistane at 20 C ± 10 % Indutane of losed iruit Referene (1) Weight V H kg LX4 D6JD LX4 D6BD LX4 D6CD LX4 D6ED LX4 D6ND LX4 D6SD LX4 D6pD LX4 D6FD LX4 D6GD LX4 D6MD LX4 D6UD LX4 D6RD For 3-pole ontators LC1 D80 or 4-pole ontators LP1 D80 Speifiations Average onsumption: 22 W. Operating range: U Control iruit voltage U Average resistane at 20 C ± 10 % Indutane of losed iruit Referene (1) Weight V H kg LX4 D7JD LX4 D7BD LX4 D7CD LX4 D7ED LX4 D7ND LX4 D7SD LX4 D7pD LX4 D7FD LX4 D7GD LX4 D7MD LX4 D7UD LX4 D7RD (1) The last 2 digits in the referene represent the voltage ode EN_Ver6.0.fm/5

12 Referenes TeSys ontators 0 d.. oils for 3 or 4-pole ontators LC1 D For ontators LC1 D115, D150 Speifiations Consumption: inrush 270 to 365 W, sealed 2.4 to 5.1 W. Operating range: U. Coils with integral suppression devie fitted as standard, lass B Control iruit voltage U Average resistane at 20 C ± 10 % Indutane of losed iruit Referene (1) Weight V H kg LX4 D8BD LX4 D8ED LX4 D8ND LX4 D8SD LX4 D8FD LX4 D8GD LX4 D8MD LX4 D8pD LX4 D8UD LX4 D8RD (1) The last 2 digits in the referene represent the voltage ode EN_Ver6.0.fm/6

13 Referenes TeSys ontators 0 Wide range d.. oils (for speifi appliations) for 3 or 4-pole ontators For 3-pole ontators LC1 D40 D65 or 4-pole ontators LP1 D40 D65 Speifiations Average onsumption: 22 W. Operating range: U. Coils with "TH" treatment as standard Control iruit voltage U Average resistane at 20 C ± 10 % Indutane of losed iruit Referene (1) Weight V H kg LX4 D6JW LX4 D6BW LX4 D6CW LX4 D6EW LX4 D6SW LX4 D6FW LX4 D6pW LX4 D6MW For 3-pole ontators LC1 D80 or 4-pole ontators LP1 D80 Speifiations Average onsumption: 23 W. Operating range: 0.75 to 1.2 U Coils with "TH" treatment as standard. Control iruit voltage U Average resistane at 20 C ± 10 % Indutane of losed iruit Referene (1) Weight V H kg LX4 D7JW LX4 D7BW LX4 D7CW LX4 D7EW LX4 D7SW LX4 D7FW LX4 D7MW (1) The last 2 digits in the referene represent the voltage ode EN_Ver6.0.fm/7

14 Shemes TeSys ontators 3 Model d ontators Contators 3-pole ontators (Referenes: pages 24501/2 to 24502/3) LC1 D09 to D150 4-pole ontators (Referenes: pages 24502/2 and 24502/3) LC1 DT20 to DT40 LC1 D LC1 D098 to D258 LC1 and LP1 D40008 to D80008 Front mounting add-on ontat bloks Instantaneous auxiliary ontats (Referenes: page 24511/3) 1 N/O LAD N10 (1) 1 N/C LAD N01 (1) 1 N/O + 1 N/C LAD N11 2 N/O LAD N /NO (93) (94) T1/2 1/L1 T2/4 3/L2 T3/6 5/L3 T4/8 7/L /NO 22 21/NC T1/2 1/L1 T2/4 3/L2 T3/6 5/L3 T4/8 7/L4 2 1 R2 R1 R4 R /NO 22 21/NC R2 R R4 R3 T1/2 1/L1 T2/4 3/L2 T3/6 5/L /NO 22 21/NC 2 N/C LAD N02 2 N/O + 2 N/C LAD N22 1 N/O + 3 N/C LAD N13 4 N/O LAD N40 4 N/C LAD N04 2 N/O + 2 N/C inluding 1 N/O + 1 N/C make before break LAD C22 3 N/O + 1 N/C LAD N31 Instantaneous auxiliary ontats onforming to standard EN (Referenes: page 24511/3) 1 N/O + 1 N/C LAD N11G 1 N/O + 1 N/C LAD N11P 2 N/O + 2 N/C LAD N22G 2 N/O + 2 N/C LAD N22P 3 N/O + 1 N/C LAD N31G 3 N/O + 1 N/C LADN31P 1 N/O + 3 N/C LAD N13G 1 N/O + 3 N/C LAD N13P 32 31/NC 44 43/NO 64 63/NO 14 13/NO 22 21/NC 34 33/NO 44 43/NO 32 31/NC 42 41/NC 52 51/NC 64 63/NO 14 13/NO 22 21/NC 32 31/NC 42 41/NC 32 31/NC 44 43/NO 14 13/NO 22 21/NC 32 31/NC 42 41/NC 64 63/NO 14 13/NO 22 21/NC 32 31/NC 44 43/NO 52 51/NC 62 61/NC 72 71/NC 82 81/NC 62 61/NC 76 75/NC 88 87/NO 62 61/NC 74 73/NO 84 83/NO 52 51/NC 62 61/NC 62 61/NC 72 71/NC 84 83/NO 62 61/NC 72 71/NC 82 81/NC 64 63/NO 74 73/NO 84 83/NO 42 41/NC (91) (92) 62 61/NC 64 63/NO (1) Items in brakets are for bloks mounted on right-hand side of ontator. Seletion : Charateristis : pages 24505/2 to 24505/7 Referenes : pages 24501/2 to 24511/7 Dimensions : pages 24531/2 to 24531/ EN_Ver4.0.fm/2

15 Shemes (ontinued) Contators 3 Model d ontators Front mounting add-on ontat bloks Dust and damp proteted instantaneous auxiliary ontats (Referenes: page 24511/3) 2 N/O (24-50 V) L DX20 2 N/C (24-50 V) L DX02 2 N/O (5-24 V) L DY20 2 N/O proteted (24-50 V) 2 N/O standard L DZ40 2 N/O proteted (24-50 V) + 1 N/O + 1 N/C standard L DZ31 Time delay auxiliary ontats (Referenes: page 24511/4) On-delay 1 N/O + 1 N/C LAD T Off-delay 1 N/O + 1 N/C LAD R On-delay 1 N/C + 1 N/O break before make LAD S 56 55/NC 68 67/NO 58 57/NO 66 65/NC 56 55/NC 68 67/NO 64 63/NO 52 51/NC 62 61/NC 64 63/NO 64 63/NO 74 73/NO 84 83/NO 62 61/NC 74 73/NO 84 83/NO Mehanial lath bloks (Referenes: page 24511/4) LAD 6K10 and LA6 DK20 E2 E1 Side mounting add-on ontat bloks Instantaneous auxiliary ontats (Referenes: page 24511/3) 1 N/O + 1 N/C LAD 8N11 (1) 2 N/O LAD 8N20 (1) 2 N/C LAD 8N02 (1) 1 1 (183) (184) /NC (171) (172) 1 1 (183) (184) /NO (173) (174) /NC (281) (282) /NC (271) (272) (1) Items in brakets are for bloks mounted on right-hand side of ontator. Eletroni serial timer modules On-delay LA4 DTpU Auto-Man-Stop ontrol modules LA4 DMp 0 K t (1) Auto /man I/O B1 K (1) PLC. Interfae modules Relay interfae Relay with manual override Solid state LA4 DFp LA4 DFBQ LA4 DLp LA4 DWBp E1 + E2 E1 + E2 E1 + E2 E1 + E2 K K K K Referenes: page 24511/7. Seletion : Charateristis : pages 24505/2 to 24505/7 Referenes : pages 24501/2 to 24511/7 Dimensions : pages 24531/2 to 24531/ EN_Ver4.0.fm/3

16 Dimensions TeSys ontators 3 Model d ontators Control iruit: a.. LC1 D09 D18 (3-pole) Minimum eletrial learane 44 LA4 LC1 D25 D38 (3-pole), LC1 DT20 DT40 (4-pole) 44 Minimum eletrial learane LA4 b b b1 b , ,5 (LAD 8) (LAD 8) (1) ,5 (LAD 8) 45 12,5 (LAD 8) (1) LC1 D09 D18 D093 D123 D099 D129 D25 D38 D183 D323 DT20 & DT25 DT203 & DT253 DT32 & DT40 b without add-on bloks b1 with LAD 4BB with LA4 Dp2 110 (1) 123 (1) (1) 114 (1) 123 (1) 114 with LA4 DF, DT 119 (1) 132 (1) (1) 123 (1) 132 (1) 129 with LA4 DW, DL 126 (1) 139 (1) (1) 130 (1) 139 (1) 190 without over or add-on bloks with over, without add-on bloks with LAD N or C (2 or 4 ontats) with LA6 DK10, LAD 6K with LAD T, R, S with LAD T, R, S and sealing over (1) Inluding LAD 4BB LC1 D40 D65 (3-pole), LC1 D65004, D40008 & D65008 (4-pole) LC1 D80 & D95 (3-pole), LC1 D80004 & D80008 (4-pole) Minimum eletrial learane LA4 Minimum eletrial learane LA4 DT323 & DT b1 127 b ,5 (LAD 8) a 12,5 (LAD 8) ,5 a 12,5 (LAD 8) (LAD 8) LC1 D40 D65 D40008 D80, D65004 D95, D65008 D80004 D80008 a b1 with LA4 Dp with LA4 DB3 135 with LA4 DF, DT with LA4 DM, DW, DL without over or add-on bloks with over, without add-on bloks with LAD N (1 ontat) with LAD N or C (2 or 4 ontats) with LA6 DK with LAD T, R, S with LAD T, R, S and sealing over LC1 D115 and D150 (3-pole), LC1 D (4-pole) LC1 D115, D150 D D D D a b1 with LA4 D with LA4 DF, DT with LA4 DM, DL with LA4 DW without over or add-on bloks with over, without add-on bloks with LAD N or C (2 or 4 ontats) with LA6 DK with LAD T, R, S with LAD T, R, S and sealing over Minimum eletrial learane LAD 8 LA4 a b1 Seletion : Charateristis : pages 24505/2 to 24505/7 Referenes : pages 24501/2 to 24502/3 Shemes : pages 24532/2 and 24532/ EN_Ver7.1.fm/2

17 Dimensions TeSys ontators 3 Model d ontators Control iruit: d.. or low onsumption LC1 D09 D18 (3-pole) Minimum eletrial learane LC1 D25 D38 (3-pole) Minimum eletrial learane b b LC1 D09 D18 D093 D123 D099 D129 D25 D38 D183 D323 b without over or add-on bloks with over, without add-on bloks with LAD N or C (2 or 4 ontats) with LA6 DK with LAD T, R, S with LAD T, R, S and sealing over LC1 DT20 to DT40 (4-pole) Minimum eletrial learane b LC1 DT20 & DT25 D098 & D128 DT203 & DT253 D0983 & D1283 DT32 & DT40 D188 D258 b with over with LAD N or C (2 or 4 ontats) with LA6 DK with LAD T, R, S with LAD T, R, S and sealing over LC1 D40 D65 (3-pole) LC1 D65004, LP1 D40008 D65008 (4-pole) LC1 D80 & D95 (3-pole) LP1 D80004, LP1 D80008 (4-pole) DT323 & DT403 D1883 & D2583 Minimum eletrial learane Minimum eletrial learane LC1 D40 D65 LP1 D65004 LP1 D40008 & D65008 LC1 D80 & D95 LP1 D80004 without over or add-on bloks with over, without add-on bloks with LAD N (1 ontat) with LAD N or C (2 or 4 ontats) with LA6 DK with LAD T, R, S with LAD T, R, S and sealing over LC1 D115ppp and LC1 D150ppp with oil: see page 24531/2 LP1 D80008 Seletion : Charateristis : pages 24505/2 to 24505/7 Referenes : pages 24501/2 to 24502/3 Shemes : pages 24532/2 and 24532/ EN_Ver7.1.fm/3

18 Mounting TeSys ontators 3 Model d ontators LC1 D09 D38, DT20 DT40 On mounting rail AM1 DP200, DR200 or AM1 DE200 (width 35 mm) LC1 D40 to D95, LP1 D40 to D80 On mounting rail AM1 DL200 or DL201 (width 75 mm) On mounting rail AM1 EDppp or AM1 DE200 (width 35 mm) = b = = b = = 127 = LC1 D09 D18 D25 D38 DT2 & DT25 DT32 & DT40 Control iruit: a.. LC1 D40 D65 D80 & D95 b (AM1 DL200) (1) (AM1 DP200 or DR200) (1) (AM1 DL201) (1) (AM1 DE200) (1) (AM1 EDppp or DE200) (1) Control iruit: d.. Control iruit: d.. b LC1 D40 D65 D80 & D95 (AM1 DP200 or DR200) (1) (AM1 DL200) (1) (AM1 DE200) (1) (AM1 DL201) (1) LP1 D40 D65 D80 (AM1 DL200) (AM1 DL201) (1) with safety over. (1) with safety over. LC1 D115, D150 On 2 mounting rails DZ5 MB on 120 mm entres 100 = = 158 Control iruit: a.. or d.. LC1 D115 & D150 D1156 & D1506 (AM1 DP200 or DR200) (AM1 DE200 or EDppp) LC1 D40 D95, LP1 D40 D80 On 2 mounting rails DZ5 MB on 120 mm entres DZ5 ME5 Control iruit: a.. LC1 D40 D65 D80 & D95 with over Control iruit: d.. LC1 D40 D65 D80 & D95 with over LP1 D40 & D65 D Seletion : Charateristis : pages 24505/2 to 24505/7 Referenes : pages 24501/2 to 24502/3 Shemes : pages 24532/2 and 24532/ EN_Ver7.1.fm/4

19 Mounting (ontinued) TeSys ontators 3 Model d ontators LC1 D09 to D38 and LC1 DT20 DT40 On 2 mounting rails DZ5 MB 15 H1 DZ5 ME8 LC1 D09 D38 and LC1 DT20 DT40 On pre-slotted mounting plate AM1 PA, PB, PC G H Control iruit: a.. d.. LC1 D09 D18 D25 D38 D09 D18 D25 D38 with over G H H pole ontators LC1 DT20 & DT25 DT32 & DT40 DT20 & DT25 DT32 & DT G H H LC1 D40 D95, LP1 D40 D80 On pre-slotted mounting plate AM1 PA, PB, PC H 110 AF1 EA4 G 40 AF1 EA6 Control iruit: a.. d.. Control iruit: a.. d.. LC1 D09 D18 D25 D38 D09 D18 D25 D38 LC1 D40 D65 D80 & D95 D40 D65 D80 & D95 with over with over G LP1 D40 & D65 D80 H 60/70 60/ without over LC1 DT20 & DT25 DT32 & DT40 DT20 & DT25 DT32 & DT40 with over G H LC1 D09 D38 Panel mounted AC DC 2xM4 2xM4 2xØ4,5 LC1 D40 D95, LP1 D40 D80 Panel mounted Control iruit: a.. d.. Control iruit: a.. d.. LC1 D09 D18 D25 D38 D09 D18 D25 D38 LC1 D40 D65 D80 & D95 D4 D65 D80 & D95 with over with over pole ontators LC1 DT20 & DT25 = 60/70 = = 35 = DT32 & DT40 DT20 & DT25 = 50 = = 35 = DT32 & DT40 = 40 = LP1 D40 & D65 D80 with over without over LC1 D115, D150 Panel mounted = 100/110 = 3xØ6,5 130 = 158 = G = = LC1 D115 D1156 D150 D G (3-pole) 96/110 96/110 96/110 96/110 G (4-pole) 130/ /144 Seletion : Charateristis : pages 24505/2 to 24505/7 Referenes : pages 24501/2 to 24502/3 Shemes : pages 24532/2 and 24532/ EN_Ver7.1.fm/5

20 Cross-referene table TeSys ontrol and protetion omponents 3-pole ontators, a.. (1) Connetion for ables with or without able end for lugs or bars for Faston onnetors Old New Old New Old New referenes referenes referenes referenes referenes referenes LC1-D0900 LC1-D09 LC1-D09006 LC1-D096 LC1-D09009 LC1-D099 LC1-D0910 LC1-D09 LC1-D09106 LC1-D096 LC1-D09109 LC1-D099 LC1-D0901 LC1-D09 LC1-D09016 LC1-D096 LC1-D09019 LC1-D099 LC1-D1200 LC1-D12 LC1-D12006 LC1-D126 LC1-D12009 LC1-D129 LC1-D1210 LC1-D12 LC1-D12106 LC1-D126 LC1-D12109 LC1-D129 LC1-D1201 LC1-D12 LC1-D12016 LC1-D126 LC1-D12019 LC1-D129 LC1-D1800 LC1-D18 LC1-D18006 LC1-D186 LC1-D1810 LC1-D18 LC1-D18106 LC1-D186 LC1-D1801 LC1-D18 LC1-D18016 LC1-D186 LC1-D2500 LC1-D25 LC1-D25006 LC1-D256 LC1-D2510 LC1-D25 LC1-D25106 LC1-D256 LC1-D2501 LC1-D25 LC1-D25016 LC1-D256 LC1-D3200 LC1-D32 LC1-D32006 LC1-D326 LC1-D3210 LC1-D32 LC1-D32106 LC1-D326 LC1-D3201 LC1-D32 LC1-D32016 LC1-D326 LC1-D3810 LC1-D38 LC1-D38106 LC2-D386 LC1-D3801 LC1-D38 LC1-D38016 LC1-D386 LC1-D4011 LC1-D40 LC1-D40116 LC1-D406 LC1-D5011 LC1-D50 LC1-D50116 LC1-D506 LC1-D6511 LC1-D65 LC1-D65116 LC1-D656 LC1-D8011 LC1-D80 LC1-D80116 LC1-D806 LC1-D9511 LC1-D95 LC1-D95116 LC1-D956 LC1-D11500 LC1-D115 LC1-D LC1-D1156 LC1-D15000 LC1-D150 LC1-D LC1-D pole ontators, a.. (1) LC1-D12004 LC1-DT25 LC1-D LC1-DT256 LC1-D12008 LC1-D128 LC1-D LC1-D1286 LC1-D25004 LC1-DT40 LC1-D LC1-DT406 LC1-D25008 LC1-D258 LC1-D LC1-D2586 (1) Main voltages: odes to be added to the end of the new referenes a Volts Code B7 E7 M7 P7 Q7 V7 3-pole ontators, d.. (2) LP1-D0910 LC1-D09 LP1-D09106 LC1-D096 LP1-D09109 LC1-D099 LP1-D0901 LC1-D09 LP1-D09016 LC1-D096 LP1-D09019 LC1-D099 LP1-D1210 LC1-D12 LP1-D12106 LC1-D126 LP1-D12109 LC1-D129 LP1-D1201 LC1-D12 LP1-D12016 LC1-D126 LP1-D12019 LC1-D129 LP1-D1810 LC1-D18 LP1-D18106 LC1-D186 LP1-D1801 LC1-D18 LP1-D18016 LC1-D186 LP1-D2510 LC1-D25 LP1-D25106 LC1-D256 LP1-D2501 LC1-D25 LP1-D25016 LC1-D256 LP1-D3210 LC1-D32 LP1-D32106 LC1-D326 LP1-D3201 LC1-D32 LP1-D32016 LC1-D326 LP1-D4011 LC1-D40 LP1-D40116 LC1-D406 LP1-D5011 LC1-D50 LP1-D50116 LC1-D506 LP1-D6511 LC1-D65 LP1-D65116 LC1-D656 LP1-D8011 LC1-D80 LP1-D80116 LC1-D806 LC1-D11500 LC1-D115 LC1-D LC1-D1156 LC1-D15000 LC1-D150 LC1-D LC1-D pole ontators, d.. (2) LP1-D12004 LC1-DT25 LP1-D LC1-DT256 LP1-D12008 LC1-D128 LP1-D LC1-D1286 LP1-D25004 LC1-DT40 LP1-D LC1-DT406 LP1-D25008 LC1-D258 LP1-D LC1-D2586 (2) Main voltages: odes to be added to the end of the new referenes Volts Code BD ED SD 24530_Ver3.00-EN.fm/2 Shneider Eletri

DATA SHEET LC-D CONTACTORS

DATA SHEET LC-D CONTACTORS Issued November 2009 DATA SHEET LC-D CONTACTORS Based on Shneider MKTED205103EN Catalogue Charateristis 5 d Contator type LC1 D09 D18 D25 D38 D40 D50 D95 D115 and D150 DT20 and DT25 DT32 and DT40 Environment

More information

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors 90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp

More information

TeSys contactors. Characteristics. Environment Rated insulation voltage 5/50. Contactor type LC1 D09 D18 DT20 and DT25. DT60A and DT80A.

TeSys contactors. Characteristics. Environment Rated insulation voltage 5/50. Contactor type LC1 D09 D18 DT20 and DT25. DT60A and DT80A. Characteristics Contactor type LC1 D09 D18 DT20 and DT2 Environment Rated insulation voltage V 600 D2 D38 DT32 and DT40 D40A D6A DT60A and DT80A V 690 1000 D80 D9 D11 and D10 Rated impulse withstand voltage

More information

Contactors. d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. References

Contactors. d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. References d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. c Standard power ratings Rated Instantaneous Basic reference. Weight of 3-phase motors operational auxiliary

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30 Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,

More information

5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors

5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors Contents 0 - Contactors Selection guides.............................................page /2 b General, selection of contactors....................... pages /16 k contactors and reversing contactors b

More information

C -5 to +55 (0.8 to 1.1Uc) Permissible o

C -5 to +55 (0.8 to 1.1Uc) Permissible o T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC 60947-4

More information

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660 Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

2.3 LA1-DN10, DN01 LA6-DK LA8-DN LA1-DN LC1-LP1 LA8-DN LA1-DN, DC LA2-DT, DS LA3-DR LA1-DX, DY, DZ

2.3 LA1-DN10, DN01 LA6-DK LA8-DN LA1-DN LC1-LP1 LA8-DN LA1-DN, DC LA2-DT, DS LA3-DR LA1-DX, DY, DZ 110-17V AC-DC 50/60Hz E1 E LA1-DN10, DN01 0 LA6-DK LA6 DK10 LA8-DN LA1-DN.3 LA8-DN LC1-LP1 LA1-DN, DC LA-DT, DS LA3-DR LA1-DX, DY, DZ See right-hand page for mounting possibilities according to the contactor

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

Low-watt Type Solenoid Valve

Low-watt Type Solenoid Valve Low-watt ype Solenoid Valve Features hese solenoid valves use low-wattage type oils (: 5 W, C: 12 W). his valve an e driven diretly from a programmale sequene ontroller sine it has a low urrent requirement.

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com TeSys D, K Catalogue 2017 'S335' series contactors for electrodomestic applications schneider-electric.com Presentation TeSys D, TeSys K TeSys D, TeSys K: S335 series Best-in-class contactors for electrodomestic

More information

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC Product data sheet Characteristics LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 -

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC Product datasheet Characteristics LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 -

More information

Low Voltage. EasyPact TVS. Motor starters from 6A to 630A. Catalog 2015

Low Voltage. EasyPact TVS. Motor starters from 6A to 630A. Catalog 2015 Low Voltage EasyPact TVS Motor starters from 6A to 630A Catalog 2015 Designed for the essential EasyPact TVS General contents EasyPact TVS contactors, 6 A to 630 A A-1 EasyPact TVS thermal overload relays

More information

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition Product datasheet Characteristics LC1F400E7 Complementary [Uimp] rated impulse withstand voltage Overvoltage category [Ith] conventional free air thermal current Main Range Product name Product or component

More information

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC Product datasheet Characteristics LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 -

More information

TeSys GS. Data for Designers. Contents

TeSys GS. Data for Designers. Contents TeSys GS Technical Data for Designers Contents Characteristics: > switch-disconnector... B5/16 to B5/21 > auxiliary contacts...b5/22 Dimensions... B5/23 to B5/31 Schemes...B5/31 B5/15 Characteristics -

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction Introduction Introduction Schneider Electric offers a complete line of products for the manual control and protection of motors. This catalog covers those devices designed to meet IEC standards for protection

More information

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS Characteristics SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS Product availability : Stock - Normally stocked in distribution facility Price* : 68.00 USD Main Range of product Product or component type Device

More information

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30 Contactors KNL KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30 Adaptable to various control requirements with ability of mounting from one to four additional auxiliary contacts. Versatile product capable

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

References 4 Fuse carriers

References 4 Fuse carriers References components 000_ -pole basic blocks Rating Cartridge fuse size umber of early break contacts () Single-phase protection device () Reference () Connection by spring terminals A 0 x 8 () Without

More information

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France Contact us ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F-69687 Chassieu cedex / France You can find the address of your local sales organisation on

More information

LR9 F OVERLOAD RELAYS

LR9 F OVERLOAD RELAYS Issued November 2009 DATA SHEET LR9 F OVERLOAD RELAYS Based on Schneider MKTED2050EN Catalogue General 6 Motor protection Operating conditions There are many possible causes of electric motor failure.

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

Pendant control stations 6

Pendant control stations 6 Characteristics For control circuits Environment Conformity to standards EN/IEC 0-- EN/IEC 00-, UL 0, CSA C- n EN/IEC 0-- and EN/ISO 0: 00 for versions with trigger action Emergency stop Protective treatment

More information

M Point & 3-Point Electric Damper-Actuator

M Point & 3-Point Electric Damper-Actuator Setion D 5.211 Produt Bulletin M934 ssue Date 122 M934 2-Point & 3-Point Eletri Damper-Atuator Appliation These Johnson Controls eletri atuators have been speially developed for use with small air dampers

More information

ELECTRONICS TRANSFORMERS SWITCHING POWER SUPPLIES

ELECTRONICS TRANSFORMERS SWITCHING POWER SUPPLIES ELECTRONICS TRANSFORMERS SWITCHING POWER SUPPLIES 7000 SERIES A fully ertified range of PCB mounting Power supplies from 1 W up to 10 W myrra.om Presenting the Eletroni Transformers miniature power supplies

More information

Associated controllers Controller selection

Associated controllers Controller selection Assoiated ontrollers Controller seletion 053058 053058 By ombining a remote-operated sourehangeover system with an integrated BA or UA automati ontroller, it is possible to automatially ontrol soure transfer

More information

ELECTRONIC TRANSFORMERS SWITCHING POWER SUPPLIES

ELECTRONIC TRANSFORMERS SWITCHING POWER SUPPLIES ELECTRONIC TRANSFORMERS SWITCHING POWER SUPPLIES 7000 SERIES A fully ertified range of PCB mounting Power supplies from 1 W up to 10 W myrra.om ELECTRONIC TRANSFORMERS Serie 7000 Filtering Transformer

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description

More information

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated 11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.

More information

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1

More information

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line 2 Contactores Compactos CWC0 Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors

More information

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101428D0201 28/03/11 -.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)

More information

Control stations and enclosures Pendant control stations, for control circuits Double insulated, type XAC-A

Control stations and enclosures Pendant control stations, for control circuits Double insulated, type XAC-A Characteristics Environment Conforming to standards IEC 947-5-1, EN 60947-5-1 Approvals Protective treatment NEMKO. Special version : UL Listed A600-Q600, CSA A600-Q600 Standard version : TH Ambient air

More information

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals NSL..S 4-pole / 8-pole Contactor Relays - Spring DC Operated Description - 1-stack contactor relays: 4-pole, - 2-stack contactor relays: 8-pole, - Mechanically linked contact elements available, - Low

More information

TeSys D Overload Relays

TeSys D Overload Relays TeSys D Contactors and Overload Relays TeSys D Overload Relays Table.24: TeSys D Overload Relays Ambient Compensated, Bimetallic, Direct Mounting Current Setting Range (A) For Direct Mounting to LC1...

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

K50H004UP cam changeover switch - 4-pole A - screw mounting

K50H004UP cam changeover switch - 4-pole A - screw mounting Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

Thermal overload relays Type TA Class 10

Thermal overload relays Type TA Class 10 Thermal overload relays Type TA Class Thermal Overload relays Description Available for starter construction with A Line contactors and separate panel mounting Designed for close couple mounting Separate

More information

Diaphragm Seals NEW! For Pressure Products For Pressure Products

Diaphragm Seals NEW! For Pressure Products For Pressure Products NEW! For Produts For Produts Diaphragm Seals Produt Overview Introdution Diaphragm Seals (or Chemial Seals) use a flexible barrier, or diaphragm, to isolate a pressure sensor (swith or transduer) from

More information

K30H001YP cam star-delta switch - 3-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

TeSys GS & DF Fuse protection

TeSys GS & DF Fuse protection TeSys GS & DF Fuse protection Simple and effective protection TeSys GS Fuse disconnect switches Total isolation between poles Safe replacement of the fuses (double breaking system) Frontal and right side

More information

Full Port Ball Valves

Full Port Ball Valves for two way ontrol of hot water and hilled water systems Desription The Full Port Series are atuated two way ball valves for digital or analog ontrol of hot and hilled water systems up to 50% glyol. Eah

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control

More information

VQD: 2-way flanged valve, PN 6

VQD: 2-way flanged valve, PN 6 Ambient onditions 1) Operating temperature 2) -10...150 C Produt data sheet 56.112 VQD: 2-way flanged valve, PN 6 How energy effiieny is improved Effiient use in ontinuous ontrol systems Features Continuous

More information

Symbol indicating an action that must not be done. Symbol indicating an action that should be done. Symbol indicating related or useful information

Symbol indicating an action that must not be done. Symbol indicating an action that should be done. Symbol indicating related or useful information Installation Manual Using the Produt Safely Safety Instrutions This guide explains how to suspend the EV-100/EV-105 from a eiling or install it on a wall using the supplied Diret Mount. Make sure you read

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description

More information

VQE: 2-way flanged valve, PN 16

VQE: 2-way flanged valve, PN 16 Ambient onditions 1) Operating temperature 2) -10...150 C Produt data sheet 56.117 VQE: 2-way flanged valve, PN 16 How energy effiieny is improved Effiient use in ontinuous ontrol systems Features Continuous

More information

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories Switching & ontrols Selection Guide... 922 1V Series... 923 Dimensions... 929 Accessories... 932 ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks

More information

Controls. CONTACTORS CWB Line (up to 40A)

Controls. CONTACTORS CWB Line (up to 40A) Controls CONTACTORS CWB Line (up to 40A) 0800 367 934 Contactors CWB Line (up to 40A) CONTACTORS CWB Line (up to 40A) Summary New WEG CWB Contactors 4 The Technology Within 6 Energy Savings 7 Easy Panel

More information

Efficor* Intro. Conformity to standards. Ambient conditions. Climatic resistance (IEC 68-2) Approvals/Marking. Mounting positions

Efficor* Intro. Conformity to standards. Ambient conditions. Climatic resistance (IEC 68-2) Approvals/Marking. Mounting positions fficor* onformity to standards /N 60947-1 04 /N 60947-4-1 UL508 /N 60947-5-1 UL486 /N 60947-5-4 S22- N500 N 16 101/102 N50012 N50005 pprovals/marking mbient conditions Storage temperature -55º to +80º

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Safety Interlock Switches D4S-N D4SN For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Slim Safety Door Switches with

More information

Industrial contactors CTX-1

Industrial contactors CTX-1 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 Industrial contactors /04/05/10/12/14/15/20/22/24/25/30/32/34/35/40/42/44/45 CONTENTS PAGE 1. Use... 1 2. Range... 1 3. Electrical

More information

Bulletin 100-D IEC Contactors

Bulletin 100-D IEC Contactors Bulletin 100-D IEC Contactors Electronic and conventional coils AC & DC Integrated PLC interface Low power pick-up & hold-in Wide voltage ranges Complete range of accessories Environmentally friendly Compact

More information

Auxiliary contact blocks - with spring terminals Accessories

Auxiliary contact blocks - with spring terminals Accessories Auxiliary contact blocks - with spring terminals Accessories CA3-10S 1SBC101037F0014 Description The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits. CA3

More information

Three Way Ball Valves

Three Way Ball Valves for three way ontrol of hot water and hilled water systems Desription Fig. i Artist s rendering of the glass filled polymer insert integral to eratin models that restrits the flow and provides a wider

More information

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0 MainswitchSurfacemounting Partno. T0-2-1/I1/SVB-SW Articleno. 207148 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

Accessories for Contactors and Contactor Relays

Accessories for Contactors and Contactor Relays 4/0 Accessories for Contactors and Contactor Relays Contents Accessories for A... Series and BC... Series Contactors and for Contactor Relays Auxiliary Contact Blocks - Front Mounting... 4/2 Auxiliary

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h No Filter 81.6 % Auto 9.1 m3/h 250.0 m3/h Auto 99.7 m3/h 100.0 m3/h Auto 91.3 m3/h 92.0 m3/h Auto 40.0 m3/h 7. MW Auto 50.7 m3/h 50.0 m3/h 7.2 % Auto.6 % 45.0 % ABB NF Contactor Relays Overview...3 Ordering

More information

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Characteristics interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Stock Code: Stock - Normally stocked in distribution facility Price*: 4.20 USD Complementary Shape of pin Jul 8, 2015 Main Commercial

More information

EXPLOSION-PROOF MOTOR DRIVEN CABLE REELS MCR

EXPLOSION-PROOF MOTOR DRIVEN CABLE REELS MCR MCR Bull motor driven able reel is speially designed and manufatured for mobile feeding power systems. The feeding is realized by low voltage eletrial ables. The mobile systems are generally overhead ranes

More information

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR. Presentation Compact design, plastic, with reset knob, types XCNR and XCNTR b XCNR with cable entry v With head for linear movement (plunger) Page v With head for rotary movement (lever) Page b XCNTR with

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives Safety Interlock Switches DSL Compact -Contact uard Lock Safety-Door Switch Two types are available: a connector type that reduces wiring time and a detachable terminal block type. Robust and durable metal

More information

Modular contactor for installation into distribution boards

Modular contactor for installation into distribution boards Modular contactor for installation into distribution boards Description Modular contactors are used for installation in consumer units in dwellings, business premises, hotels, hospitals, shopping centres,

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays New generation of Contactors from LS Industrial Systems Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

Circuit Breakers. Switching & Controls.  Selection Guide NC1V Series Dimensions... Switching & ontrols Selection Guide... 1028 1V Series... 1029 Dimensions... 1035 www.ide.com/circuitbreaker ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

Safety Limit Switch

Safety Limit Switch Safety Limit Switch D4B-@N CSM_D4B-_N_DS_E_5_1 Snap-action contact with certified direct operation certification. Maintenance, seal, and resistance to shock increased and direct mechanism added. Three-conduit

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

FUJI Magnetic Contactors and Motor Starters

FUJI Magnetic Contactors and Motor Starters FUJI Magnetic Contactors and Motor Starters Technical Information AEH28a CONTENTS Chapter Contactors and Starters - International standards... 4-2 Ratings and specifications... 8-3 Performance and characteristics...

More information