Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

Size: px
Start display at page:

Download "Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions..."

Transcription

1 Switching & ontrols Selection Guide V Series Dimensions ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks ircuit Breakers Table of ontents LED Lighting - Pg. 1 Automation & Sensing - Pg. 21 Safety - Pg. 281 Switching & ontrols - Pg. 483 Index - Pg. 1039

2 Selection Guide ircuit Breakers Switches & Pilot Lights Selection Guide Series 1V RA RBM Signaling Lights Appearance Relays & Sockets Timers ontactors Page 1029 Visit Actuator Style Lever umber of Poles 1, 2, 3 Lever and Rocker (non-illuminated and illuminated) Lever: 1, 2, 3 Rocker: 1 Protection Method Hydraulic magnetic Electromagnetic trip Internal ircuits Auxiliary ontact Alarm ontact Inertial Delay Series current trip Relay voltage trip Optional 125V A 3A (resistive load), 30V D 2A (resistive load) Optional 125V A 3A (resistive load). 30V D 2A (resistive load) Optional (for resistance to high inrush currents) Series current trip Lever 1, 2, 3 Optional (250V A, 5A; 50V D, 1A) Optional (250V A, 5A; 50V D, 1A) Optional (250V A, 5A; 50V D, 1A) Optional (250V A, 5A; 50V D, 1A) Optional (for resistance to high inrush) Optional (for resistance to high inrush) Time Delay urves 3 types (A or D) 2 types for D; 3 types for A 2 types for D; 3 types for A Rated Voltage Rated Tripping urrents Rated Interruption apacity Approvals 1-pole 2-pole 3-pole 250V A 50/60Hz, 65V D 250V A 50/60Hz, 125V D 250V A, 50/60Hz 0.1A, 0.3A, 0.5A, 1A, 2A, 3A, 5A, 7A, 10A, 15A, 20A, 25A, 30A 0.3A, 0.5A, 0.75A, 1A, 2A, 3A, 5A, 7.5A, 10A, 15A, 20A, 25A, 30A 250V A, 50/60Hz, 65V D 1A, 2A, 3A, 5A, 7.5A, 10A, 15A, 20A, 25A, 30A, 40A, 50A 2,500A 1,000A, 250V A (50/60Hz), 65V D 1,000A, 250V A (50/60Hz), 65V D UL, SA, E, TUV, Lever: UL, SA, VDE Rocker: UL UL, c-ul, VDE Terminal Blocks 1. For dimensions, see end of each section. 2. UL recognized, applicable standard: UL1077, Supplementary Protectors. 3. ot suitable for branch circuit protection. UL Recognized File o. E68029 *E, TUV, and apply to 1V. File o. LR83454 R Series * * * File o. B ircuit Breakers

3 ircuit Breakers 1V Key features: Superior protection for a wide range of devices from sensitive electronic equipment to electrical control circuits. Applications include semiconductor manufacturing equipment, electronic controllers, computers, microprocessors, communications equipment, power supplies, machine tools, motors, and more. Excellent tripping time curve performance Flat retractable lever for safety operations Slim housing design Spring-up terminals allow for use of ring terminals Fingersafe main circuit terminals olor (red/green) contact position indicator DI rail or direct panel mounting (through-panel mounting brackets available) Optional built-in auxiliary / alarm contacts Applicable Standards ertification Mark File umber UL1077 SA 22.2 o. 235 E V ircuit Breakers E68029 LR83454 B European ommission s Low Voltage Directive GB o Electrical Applicance and Material Safety Law Technical Standard Type 1V: Lever style DI rail and panel mountng o. of Poles 1: 1-pole 2: 2-pole 3: 3-pole Series Trip Relay Trip Internal ircuit 1: Series trip (current trip) 5: Relay trip (voltage trip) Jet Part umber Structure 1V F 30A A D24V Auxiliary/Alarm ontacts 00: one 21: With one alarm contact 11: With one auxiliary contact 31: With one auxiliary contact and one alarm contact 12: With two auxiliary contacts 32: With two auxiliary contacts and one alarm contact 13: With three auxiliary contacts Inertial Delay Blank: Without F: With * Inertial delay is for A voltage only. * Available with medium and slow trip curves (not applicable with relay trip). Voltage Trip oil Voltage D24V: 24-48V D *Specified for relay trip only. Time Delay urve M: Slow A: Medium S: Instantaneous *Specified for series trip only. Rated urrent 0.1A, 0.3A, 0.5A, 1A, 2A, 3A, 5A, 7A, 10A 15A, 20A, 25A, 30A *Specified for series trip only. Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks ircuit Breakers IDE (4332) USA & anada 1029

4 1V ircuit Breakers ontactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights Internal ircuit Protection Method Specifications Series trip (current trip), Relay trip (voltage trip) Hydraulic magnetic tripping system, Magnetic tripping system (voltage trip) o. of Poles 1-pole 2-pole 3-pole Rated Voltage (A/D) 1 250V A 50/60Hz, 65V D 250V A 50/60Hz, 125V D 250V A, 50/60Hz Series Trip (urrent Trip) Relay Trip (Voltage Trip) 3 Auxiliary ontact/alarm ontact Insulation Resistance Dielectric Strength Vibration Resistance (with rated current applied) Rated Short-circuit apacity Rated urrent Operation haracteristics 2 Rated urrent Trip Voltage ontact Rating Shock Resistance (S time delay curve: 80% rated current, A, M time delay curve: 100% rated current) Electrical Life Minimum Applicable Load 250V A, 2500A 65V D, 2500A 250V A, 2500A 125V D, 2500A 0.1A, 0.3A, 0.5A, 1A, 2A, 3A, 5A, 7A, 10A, 15A, 20A, 25A, 30A Time delay curve curve M (slow), curve A (medium), S (instantaneous) Only curves M and A are also available with inertial delay option. 30A Reference Temperature 40 Operating Temperature Operating Humidity Terminal Style Weight (approx.) 250V A, 2500A 24 to 48V D (at 25 ) Voltage application duration 10 sec maximum, tripping time 0.1 sec maximum (at rated voltage) 125V A 3A (resistive load), 30V D 2A (resistive load) 24V D 1mA (resistive load, reference value) 100MΩ minimum (500V D megger) 2,000V A, 1 minute (between terminals when main contacts are open, between live parts of different poles, between live and dead parts) 600V A (between terminals when auxiliary circuits are open) Damage limits: Operating extremes: Damage limits: Operating extremes: 147 m/s 2 (10 to 55 Hz) (1-pole, 2-pole), 78 m/s 2 (3-pole) 98 m/s 2 (1-pole, 2-pole), 78 m/s 2 (3-pole) 490 m/s 2 (1-pole, 2-pole), 297 m/s 2 (3-pole) 196 m/s 2 (S, A, M curves) 10,000 cyles minimum (at rated curent), 10 operations per minute 10 to +60 (no freezing) Rated current is based on an ambient temperature of 40. When the operating temperature exceeds 40, derate the rated current by using the factors shown below. 45 ~ 85% RH (no condensation) Main ircuit Terminal Spring-up, fingersafe terminal: M4 screw (up to 20A), M5 screw (25A and 30A) Auxiliary/Alarm ontacts, Voltage oil Terminal M3.5 screw 1-pole: 90g, 2-pole: 170g, 3-pole: 260g 1 3-pole model is for A voltage only. 2 For S (instantaneous) tripping curve, a humming sound may occur when used in an A sinusoidal-wave current circuit around 80% of the rated current, however, the performance of the circuit breaker will not be affected. To avoid unnecessary tripping, do not use in circuits where inrush currents may be present. 3 Relay trip (voltage trip) type is not equipped with an overcurrent trip function. Do not use the 1V circuit breakers in environments where they are exposed to extreme temperature, humidity, dust, corrosive gases, vibration, shock, or in a circuit where inrush current may be present, otherwise unnecessary operation and damage may occur. Terminal Blocks Operating Temp. Derating Factor ircuit Breakers

5 ircuit Breakers 1V Models Specify rated current, time delay curve, or voltage trip coil voltage in place of when ordering. Internal ircuit Series Trip (urrent Trip) Relay Trip (Voltage Trip) o. of Poles 1-pole 2-pole 3-pole 1-pole Inertial Delay With With With Auxiliary ontact Alarm ontact Part o 1V One Auxiliary ontact 1V One Alarm ontact 1V V-1100F- 6 7 One Auxiliary ontact 1V-1111F- 6 7 One Alarm ontact 1V-1121F V One Auxiliary ontact 1V Two Auxiliary ontacts 1V One Alarm ontact 1V One Auxiliary ontact and One Alarm ontact 1V V-2100F- 6 7 One Auxiliary ontact 1V-2111F- 6 7 Two Auxiliary ontacts 1V-2112F- 6 7 One Alarm ontact 1V-2121F- 6 7 One Auxiliary ontact and One Alarm ontact 1V-2131F V One Auxiliary ontact 1V Two Auxiliary ontacts 1V Three Auxiliary ontacts 1V One Alarm ontact 1V One Auxiliary ontact and One Alarm ontact Two Auxiliary ontacts and One Alarm ontact 1V V V-3100F- 6 7 One Auxiliary ontact 1V-3111F- 6 7 Two Auxiliary ontacts 1V-3112F- 6 7 Three Auxiliary ontacts 1V-3113F- 6 7 One Alarm ontact 1V-3121F- 6 7 One Auxiliary ontact and One Alarm ontact Two Auxiliary ontacts and One Alarm ontact 1V-3131F V-3132F V pole 1V pole 1V A 0.3A 0.5A 1A 2A 3A 5A 7A 10A 15A 20A 25A 30A 6 Rated urrent ode 7 Time Delay urve M (slow) A (medium) S (instantaneous) 8 Voltage Trip oil Voltage D24V Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks ircuit Breakers IDE (4332) USA & anada 1031

6 1V ircuit Breakers Switches & Pilot Lights 1-pole 1V-1100 (Without auxiliary/alarm contacts) 1V-1111 (With auxiliary contact) Internal ircuits One auxiliary contact. 1V-1121 (With alarm contact) One alarm contact. 1V-1500 (Relay Trip) A B Signaling Lights 2-pole O O D 1V-2100 (Without auxiliary/alarm contacts) 1V-2111 (With auxiliary contact) 1V-2121 (With alarm contact) 1V-2500 (Relay Trip) Relays & Sockets One auxiliary contact. Also available with two auxiliary contacts One alarm contact. Also available with one auxiliary contact and one alarm contact. A B A B D D Timers 3-pole 1V-3100 (Without auxiliary/alarm contacts) 1V-3111 (With auxiliary contact) O 1V-3121 (With alarm contact) O 1V-3500 (Relay Trip) A A A ontactors Terminal Blocks ircuit Breakers One auxiliary contact. also available with two or three auxiliary contacts. O One alarm contact. Also available with one auxiliary and one alarm contact, and two auxiliary and one alarm contact. O Overcurrent-Time Delay haracteristics 40 deg ) [vertical mounting] Percent of Rated urrent Item Time Delay urve 100% 125% 150% 175% 200% 400% 600% 800% 1000% A (50/60Hz)/D A (50/60Hz) *: MAY TRIP on D S (instantaneous) O TRIP *0.005 to to to to 0.03 A (medium) O TRIP *25 to to to to 4 M (slow) O TRIP *60 to to to to 10 With Inertial Delay A (medium) With Inertial Delay M (slow) O TRIP 25 to to to 6 O TRIP 60 to to to 10 B D to to to to to 4.5 B D to to to to to 3 B D to to to 0.8 to 1.0 to

7 ircuit Breakers 1V Time in sec Time in sec Time in sec D (ote) A urrent (percent load of the rated current) Time Delay urves at 40 urve A (medium) A D (ote) urrent (percent load of the rated current) urve S (instantaneous) urrent (percent load of the rated current) ote: Inertial Delay option not available with S (instantaneous) curve. urve A (medium) With Inertial Delay Time in sec D (ote) A urrent (percent load of the rated current) urve M (slow) ote: The entire shaded area applies to A. For D, the shaded area on the right of the dashed line applies Time in sec urrent (percent load of the rated current) urve M (slow) With Inertial Delay Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks ircuit Breakers IDE (4332) USA & anada 1033

8 1V ircuit Breakers ircuit Breakers Terminal Blocks ontactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights Time Delay urve and Ambient Temperature 1V circuit breakers employ a hydraulic magnetic tripping system, where the rated current (trip current) is not affected by ambient temperatures. But the time delay may vary with the oil viscosity in the oil dash pot. Lower oil viscosity at higher temperatures results in a shorter delay, whereas at lower temperatures the delay will be longer. Temperature orrection urve The time delay curves on the preceding page are measured at 40. With reference to the following curves, time delays can be corrected according to ambient temperature. hange of Time Delay (%) Ambient Temperature ( ) The time delay is based on an ambient temperature of 40. Time delays at other temperatures are corrected according to the temperature correction curve. The time delay of the instantaneous time delay curve (S) is not affected by ambient temperature. When operating temperature exceeds 40, derate the rated current by multiplying the derating factor shown on the right. Impedance and oil Resistance Series Trip (urrent Trip) at 25 Rated urrent For A 50/60 Hz Impedance (Ω) 50 Operating Temp Derating Factor For D Resistance (Ω) urve S urves A, M urve S urves A, M 0.1A A A Tolerance: 1A A A A A A A A A A ±25% (up to 20A), ±50% (25A and 30A) Relay Trip (Voltage Trip) at 25 Tripping Voltage 24-48V Tolerance: ±25% Inertial Delay For D Resistance (Ω) Inertial delay is designed not to trip on a non-repeating single pulse of 20 times the rated current (peak value) for a duration of 8ms. In addition, circuit breakers equipped with inertial delay do not respond to high inrush currents caused by transformer or lamp loads, but perform the specified interruption on subsequent overcurrents. Inertial delay is not available with the series trip curve S (instantaneous). Percent of Rated urrent (%) Percent of rated current Pulse peak current 100 Protector rated current 2. Sinusoidal or parabolic pulse Pulse width (Duration) Pulse Width (ms) Pulse peak current Voltage Drop Due to oil Resistance or Impedance The internal resistance or impedance of a circuit breaker tends to be larger for a smaller rated current. Therefore, when circuit breakers with a small rated current are used, voltage drop should be taken into consideration. Internal resistance also varies with time delay curves, which should also be considered during installation

9 ircuit Breakers 1V 1-pole 1V V-1111 (Auxiliary ontact) 2-pole 1V-1121 (Alarm ontact) 1V-1500 (Relay Trip) 1V-2100 Dimensions (mm) M4 Terminal Screw 12.0 (up to 20A) M5 Terminal Screw (25A or more) M4 Terminal Screw (up to 20A) M5 Terminal Screw (25A or more) M3.5 Terminal Screw Terminal over M3.5 Terminal Screw 17.5 Terminal over M5 Terminal Screw (30A) M4 Terminal Srew (up to 20A) M5 Terminal Screw (25A or more) Mounting Hole Layout (M4 Mounting Screws) 2-M4 12 Mounting Hole Layout (M4 Mounting Screws) 2-M Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks ircuit Breakers IDE (4332) USA & anada 1035

10 1V ircuit Breakers Switches & Pilot Lights 2-pole 1V-2111 (one auxiliary contact) 1V-2112 (two auxiliary contacts) 29.5 M4 Terminal Srew (up to 20A) M5 Terminal Screw (25A or more) Signaling Lights 1V-2121 (one alarm contact) 1V-2131 (one auxiliary contact and one alarm contact) 3 Dimensions shown are for 1V-2111 and 1V Mounting Hole Layout (M4 Mounting Screws) M5 Terminal Screws (30A) M4 Relays & Sockets 1V-2500 (Relay Trip) M3.5 Terminal Screw Terminal over 3-pole Timers 47.0 M4 Terminal Screw (up to 20A) M5 Terminal Srew (25A or more) V ontactors 52.5 Mounting Hole Layout (M4 Mounting Screws) V-3111 (one auxiliary contact) 1V-3112 (two auxiliary contacts) 47.0 M4 Terminal Screw (up to 20A) M5 Terminal Srew (25A or more) M4 Terminal Blocks 1V-3113 (three auxiliary contacts) 1V-3121 (one alarm ontact) 48.4 ircuit Breakers 1V-3131 (one auxiliary contact and one alarm contact) 1V-3132 (two auxiliary contacts and one alarm contact) 52.5 M3.5 Terminal Srew Dimensions shown are for 1V-3111 and 1V Terminal over

11 ircuit Breakers 1V 3-pole 1V-3500 (Relay Trip) M5 Terminal Screw (30A) M3.5 Terminal Screw Terminal over 66.0 Instructions Installation Angle Applicable wire and rimp Terminals Tripping method is hydraulic magnetic. Minimum operating current varies with installation angle. Operating currents are influenced by the weight of the movable iron core. With reference to the following figures, correct the rated current. Terminal Terminal Screw 100% 120% 90% 100% Minimum operating current is calculated from the following formula: (Minimum operating current) = (Rated current) (orrection factor by installation angle) (Reference minimum tripping current rate) DI Rails Installation on DI Rail 1. Fasten the DI rail securely. 2. With the latch facing downward, install the 1V circuit breaker on the DI rail as shown below. Removal from DI Rail Using a flat screwdriver, pull the latch on the circuit breaker to remove from the DI rail. Installing Push 35mm-wide DI Rail Removing Flat Screwdriver Latch 35mm-wide DI Rail Panel Mounting Screws (not supplied) Screw Type Tightening Torque Shape M4 0.8 to 1.0 m Spring Washer Plain Washer Main ircuit Terminals Auxiliary ontact Alarm ontact Voltage oil Terminals Spring-up, fingersafe, slotted Phillips screw with square washer (up to 20A) Spring-up fingersafe terminal (25A and 30A) Slotted Phillips screw with square washer Mounting Hole Layout (M4 Mounting Screws) 2-M4 onnectable Wire Size (mm 2 ) 47.0 Applicable rimping Terminal Tightening Torque ( m) 0.25 to 1.65 R to to 2.63 R to 6.64 R to 1.65 R to to 2.63 R to 6.64 R to 1.65 R to to 2.63 R2-3.5 For wiring the main circuit terminal, use applicable crimp terminals and tighten to the recommended torque. When using the a 1V circuit breaker as a SA-certified product, use with SA-certified crimp terminals. When using the 1V circuit breaker as UL-recognized product, use with UL-recognized crimp terminals. Product Markings (Example: 1V AA) Part o. Rated Voltage Rated urrent P E S 220VA J E T 30A IRUIT PROTETOR 1V-1111 Ue 250VA 50/60Hz 65VD In 30A Suppl. Prot. I..2500A POLE 1 URVE A AUX. SW 125VA 3A 30 VD 2A A.T. 40 JAPA PSE ertification o. of Poles Time Delay urve Auxiliary/Alarm ontact Ratin Reference Operating Temperature ertification Marks Installation of Auxiliary/Alarm Terminal over After wiring the terminals, install the terminal cover by aligning with the circuit breaker as shown below. Terminal cover installed Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks ircuit Breakers IDE (4332) USA & anada 1037

12 1V ircuit Breakers Switches & Pilot Lights Accessories Appearance Part o. Description Appearance Part o. Description 9Z-MA11 Panel ut-out Mounting bracket for 1-pole model 9Z-PW1 Marking Plate Holder* Signaling Lights 9Z-MA21 Panel ut-out Mounting bracket for 2-pole model 9Z-LK1 Padlock attachment** Relays & Sockets 9Z-MA31 Panel ut-out Mounting bracket for 3-pole model 1V-AUX-V Replacement Auxiliary/ Alarm Terminal over (ylon - PA66) *Marking plate not supplied. ** Padlock not supplied. Timers 9Z-TA1 Replacement Wiring lip when using panel mount brackets ircuit Breakers Terminal Blocks ontactors

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories Switching & ontrols Selection Guide... 922 1V Series... 923 Dimensions... 929 Accessories... 932 ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks

More information

NC1V. Circuit Breakers

NC1V. Circuit Breakers 1V ircuit Breakers IDE's original Spring-up Terminals and over Provide IP20 Fingersafe Protection. 17.5 mm 3 mm 52.5 mm mm (1-pole) (2-pole) Auxiliary/alarm contact terminals are supplied with fingersafe

More information

Circuit Protector Selection Guide

Circuit Protector Selection Guide ircuit Protectors ircuit Protector Selection Guide Model NV NHS NHY NHL (w/indicator) NHV Shape ping Method No. of Poles Internal ircuit Rating Retractable Actuator Lever Rocker Rocker Lever Hydraulic-magnetic

More information

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute RA Series RA Series RAS RA Key features of the RA series include: Available in 4 different styles Excellent overload and short circuit protection Small size and high-efficiency Life expectancy of over

More information

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute NRBM circuit breakers are the largest in rated current (A to 50A) among the IDEC circuit breakers series. These small sized, high-effi ciency breakers offer a variety of protection characteristics that

More information

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute RA Series RA Series Key features of the RA series include: Available in 5 different styles Excellent overload and short circuit protection Small size and high-efficiency Life expectancy of over 0,000 operations

More information

Section. Circuit Breakers Selection Guide...N-2. NRA Series...N-3. NRBM Series...N-13. NRC Series...

Section. Circuit Breakers   Selection Guide...N-2. NRA Series...N-3. NRBM Series...N-13. NRC Series... Section Selection Guide...-2 RA Series...-3 RBM Series...-3 RC Series...-20 General Instructions...-29 Internal Circuit Overview...-29 for more information on this product family visit www.idec.com/circuitbreaker

More information

G-Series. Circuit Breaker.

G-Series. Circuit Breaker. -Series Circuit Breaker Carling Technologies -Series hydraulic/magnetic circuit breakers offer the highest quality solution to your circuit protection requirements. The -Series is designed to sense over-current

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Circuit Protectors CP31F, 32F, 33F

Circuit Protectors CP31F, 32F, 33F CP3F, 32F, 33F CP-F slim type circuit protectors 20V AC/6V DC (-pole) 0.A to 30A 20V AC/2V DC (2-pole) 0.A to 30A 20V AC (3-pole) 0.A to 30A Description FUJI's compact and high-performance CP-F series

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker -F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 694 with trip free mechanism) offering the choice of single

More information

RU Series Universal Relays

RU Series Universal Relays Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator available on plug-in relays No internal

More information

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A Thermal-Magnetic Circuit Breaker 0-S9-P9M-40033-...A Description Single pole thermal-magnetic circuit breaker with trip-free mechanism and toggle actuation. Two-chamber construction with cascade contact

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 0-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

PD-Series Ground Fault Circuit Protection

PD-Series Ground Fault Circuit Protection PD-Series Ground Fault Circuit Protection SmartGuard is an equipment ground fault protection device that functions as a standard high-quality Carling hydraulic/ magnetic circuit breaker, offering customized

More information

ø8 A8 Series Miniature Control Units

ø8 A8 Series Miniature Control Units A8 ø8 A8 Series Miniature Control Short 22-mm-long body miniature control unit series with LED illumination face and snap-action switching. Bright and clear LED illumination. All series have terminals

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 835-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 845-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-freemechanism and toggle actuation. A choice of switching characteristics

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of single pole, double pole with single pole protection,

More information

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection

More information

HS1E Series Full Size Interlock Switch with Locking Solenoid

HS1E Series Full Size Interlock Switch with Locking Solenoid HS1E Series HS1E Series Full Size Interlock Switch with Locking Solenoid HS1E Key features include: Basic unit and solenoid unit in one housing Plastic Housing: Light weight Ease of Wiring: All the terminal

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 835-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics

More information

UP Series Miniature Pilot Lights

UP Series Miniature Pilot Lights Available in Various Sizes Five illumination colors: amber, green, red, white, yellow Various sizes and design. Available with a built-in current limiting resistor. Waterproof () types available for and.

More information

Magnetic Overcurrent Circuit Breaker

Magnetic Overcurrent Circuit Breaker Magnetic Overcurrent Circuit Breaker 808-... Description ngle pole miniaturised magnetic circuit breakers with unique highspeed operating mechanism and push/pull on/off manual actuation. Fitted with electrically

More information

CIRCUIT PROTECTORS LOW VOLTAGE FUSES AIR CIRCUIT BREAKERS

CIRCUIT PROTECTORS LOW VOLTAGE FUSES AIR CIRCUIT BREAKERS CIRCUIT PROTECTORS LOW VOLTAGE FUSES AIR CIRCUIT BREAKERS Circuit protectors Circuit protectors Air circuit breakers Air circuit breakers AFaC and BaC types HRC fuses BLC, CR and CS types Super Rapid Fuses

More information

HS1E Series Full Size Solenoid Locking Switches

HS1E Series Full Size Solenoid Locking Switches HS1E Series Full Size Solenoid Locking Switches AS-Interface Safety at Work Barriers Enabling Switches Door Interlock Switches X Series E-Stops Overview HS1E features: Basic unit and solenoid unit in one

More information

Model Number Structure

Model Number Structure Solid State Relays (Single-phase) G3PB New Single-phase Solid State Relays with Compact Size for Heater Control Slim models with a thickness of only 22.5 mm are also available. Compact design achieved

More information

ø10 A1 Series Miniature Control Units

ø10 A1 Series Miniature Control Units A1 ø10 A1 Series Miniature Control Short 22-mm-long body miniature control unit series with LED illumination face and snap-action switching. Bright and clear LED illumination. All series have terminals

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

1492-CB 1492-GH 1492-GS

1492-CB 1492-GH 1492-GS 1 The Allen-Bradley Line of Devices Allen-Bradley offers 3 different lines of Circuit Breakers (Supplementary Protectors) and a line of branch circuit rated Fuse Holders. Allen-Bradley Thermal Magnetic

More information

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC Power PCB Relay G6D-ASI Reduced board space ideal for high-density mounting (45% smaller than the surface area of G6B). Slim package: measures 6.5 W x 17.5 L x 12.5 H mm Switches loads up to 5 A, 250 VAC/30

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Thermal-Magnetic Circuit Breaker M1-...

Thermal-Magnetic Circuit Breaker M1-... Thermal-Magnetic Circuit Breaker 320-...-M-... Description Two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 6034). The addition of a magnetic tripping

More information

HEAVY DUTY POWER RELAYS FEATURES

HEAVY DUTY POWER RELAYS FEATURES VDE VC HEAVY DUTY POWER RELAYS VC RELAYS Faston terminal Screw terminal mm 9 FEATURES VC power relays are designed for controlling heavy duty loads safely: Contact gap of 3 mm or more -point contacts for

More information

1 Form A 5A small size power relay for interface

1 Form A 5A small size power relay for interface 1 Form A 5A small size power relay for interface PQ RELAYS RoHS compliant Protective construction: Sealed type FEATURES 1. Compact and slim 20 mm (L) mm (W) 16 mm (H).787 inch (L).394 inch (W).630 inch

More information

6mm and 14mm Slim Interface Relay

6mm and 14mm Slim Interface Relay 6mm and mm Slim Interface Relay RV8 Series 6mm Width Electromechanical Screw Terminal Solid State Spring Clamp Terminal PRODUCT DESCRIPTION IDEC 6mm and mm interface relays provide a compact solution for

More information

Door Interlock Switches

Door Interlock Switches HSE Series HSE Series Full Size Locking Switches Overview X Series E-Stops HSE features: Basic unit and solenoid unit in one housing Plastic Housing: Light weight Ease of Wiring: All the terminal screws

More information

GT5P Series ON Delay Timers

GT5P Series ON Delay Timers T5P Series T5P Series ON Delay Key features of the T5P series include:, 5A contacts 8-pin, octal base 9 time ranges Repeat error ±0.2% maximum Control settings by hand or screwdriver Power ON and timing

More information

Relays & Sockets. RR Series Power Relays. Part Number Selection. Key features: Sockets IDEC (4332) USA & Canada

Relays & Sockets. RR Series Power Relays. Part Number Selection. Key features: Sockets IDEC (4332) USA & Canada Key features: SPDT through PDT, 0 contacts Midget power type relays vailable in pin and blade terminal styles. Options include an indicator, check button for test operations and side flange. Series Power

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

MW Series Control Units

MW Series Control Units IP waterproof and dust-proof enclosure Suitable for installation in harsh environment, such as construction machines Prevents entry of sand and dust. eliable operation under high operation load Solder/tab

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 0-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Electronic circuit breaker EBU10-T

Electronic circuit breaker EBU10-T Description The electronic circuit protector type EBU10-T (Electronic Breaker Unit) provides selective overcurrent protection in AC 230 V UPS systems. It consists of an MCB approved for short circuit interruptions

More information

PB-Series. GFCI/ELCI & Panel Seal

PB-Series. GFCI/ELCI & Panel Seal PB-Series GFCI/ELCI & Panel Seal The PB-Series utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application environments.

More information

HS5E Miniature Interlock Switches with Solenoid

HS5E Miniature Interlock Switches with Solenoid Small interlock switch with four poles and solenoid. Ideal for applications in small spaces. Compact body. 3 40 46 mm. Four-pole internal switches. Gold-plated contacts. Spring lock and solenoid lock types

More information

2c 15A, 4c 10A polarized power relays

2c 15A, 4c 10A polarized power relays c 5A, 4c A polarized power relays SP RELAYS RoHS compliant Protective construction: Dust cover type Taking advantage of the 4-gap balanced armature mechanism, S relays have met a number of relay needs

More information

Only 21.5mm depth behind panel with LED Full Face, Illumination.

Only 21.5mm depth behind panel with LED Full Face, Illumination. R LED Lamp Subminiature Lighted Pushbutton Switch Only 21.5mm depth behind panel with LED Full Face, Illumination. FEATURES Depth behind panel:only 21.5mm. LED Full Face Illumination provided. size: 14.2mm

More information

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch HS5E Series HS5E Series Miniature Solenoid Locking Switch HS5E Key features include: World s smallest 4 contact solenoid interlock switch. (35 40 46 mm.) Four contacts. Gold-plated contacts. Spring lock

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 Operating Characteristics 73

Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 Operating Characteristics 73 Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 perating Characteristics 73 Delay Curves 74 Specifications 76 Decision Tables 78 SIGLE

More information

Thermal Circuit Breaker 3120-F...

Thermal Circuit Breaker 3120-F... Description The 320 circuit breaker/switch combination is an ON/OFF switch with integral overcurrent protection (S-type TO CBE to EN/IEC 60934). The trip element is a bimetal. Type 320 is ideally suited

More information

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed PCB Relay G5LA A Cubic, Single-pole 1A Power Relay Economical cube relay with universal terminal footprint Conforms to VDE435, CQC UL recognized/ CSA certified. High switching power: 1A @ 5VAC Withstands

More information

General Specifications

General Specifications Series HB Subminiature Pushbuttons General Specifications Electrical apacity (Resistive Load) Power Level (silver): 0.1A maximum @ 30V A/ Other Ratings ontact Resistance: 50 milliohms maximum Insulation

More information

PS6R 480W Switching Power Supply

PS6R 480W Switching Power Supply ew Series PS6R 4W Switching Power Supply Reduced size and high efficiency cuts operating costs. Energy-saving 93% Efficiency Space-saving 85mm wide Efficiency (%) 96 94 92 88 86 84 82 Competitor A Competitor

More information

PS5R-S. Switching Power Supplies

PS5R-S. Switching Power Supplies TREICHL-ATM Electronic Auf der Bült 1-12 D 41189 Mönchengladbach Tel. 2166 8545 Fax 2166 8547 email: atm@treichl.de internet: www.atm-treichl.de PS5R-S Switching Power Supplies Class Create More Space

More information

HS1L Interlock Switches with Solenoid

HS1L Interlock Switches with Solenoid HS1L Interlock Switches with Solenoid 3000N locking strength (largest in class)! * Suitable for large and heavy doors. Same actuator as HS1E (actuator retention force 3000N) Six contacts in a compact housing

More information

209 Series. Magnetic Circuit Protectors

209 Series. Magnetic Circuit Protectors 29 Series Magnetic Circuit Protectors Introduction 249 Power Selector System Multi-Pole Configurations Operating Characteristics Delay Curves Specifications Decision Tables 73 75 77 79 8 82 85 87 29/29/229/249/279

More information

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality Full Size Interlock Switch with Locking Solenoid HSC Key features include: Rugged Aluminum Die-cast Housing With the actuator mounted on a movable door, and the switch on a machine, the door can be mechanically

More information

General Specifications

General Specifications Series E Light Touch Miniature Pushbuttons eneral Specifications Electrical apacity (Resistive Load) Power Level (silver): A @ 25V A for silver contacts Logic Level (gold): 0.4VA maximum @ 28V A/D maximum

More information

ø12 A2 Series Miniature Control Units

ø12 A2 Series Miniature Control Units ø2 A2 Series Miniature Control Short 22-mm-long body miniature control unit series with bright LED illumination face and snap-action switching. Degree of protection: IP40 and IP5 (IEC 0529) All series

More information

JAE Series. Magnetic Circuit Protectors. Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables

JAE Series. Magnetic Circuit Protectors. Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables JAE Series Magnetic Circuit Protectors Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables 205 207 211 213 216 217 JAE/JRE/JLE Series Hydraulic Magnetic Circuit Protectors

More information

F-Series General Specifications

F-Series General Specifications arling F-Series General Specifications F-Series breakers are available up to 700, and are also available with a 25 millivolt metering shunt construction. This optional construction provides a safe method

More information

HS1C Interlock Switches with Solenoid

HS1C Interlock Switches with Solenoid HSC es with The guard door remains locked until the machine stops completely. With the actuator mounted on the guard door and the interlock switch on the machine, the door is mechanically locked when closed.

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter.

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter. Standard AC SB5W Standard AC Intro duction Induction Reversible Right -Angle Gearheads SB5W AC Speed Control Inverter SB5W US ES2 FE1/FE2 Watertight, Dust-Resistant Torque Accessories Installation A-143

More information

Switches & Pilot Devices

Switches & Pilot Devices ø16mm - 6 Series Key features: 5/8 (16mm) mounting holes ocking lever removable contact blocks Solder terminal or PB terminal options Available assembled or as sub-components Worldwide approvals Incandescent

More information

QF(19) - Series Miniature Circuit Breakers

QF(19) - Series Miniature Circuit Breakers Dual mount 1 pole Dual mount 2 pole Dual mount 3 pole Dual mount 3+N Features AC circuit breaker Hydraulic-magnetic technology % rating capability, independent of ambient temperature One, two, three pole,

More information

AP/UP, AP/MIL Series Magnetic Circuit Protectors

AP/UP, AP/MIL Series Magnetic Circuit Protectors AP/UP, AP/MIL AP/UP, AP/MIL Series Magnetic Circuit Protectors Introduction 68 Single Pole 69 Multi-Pole 70 Configurations 72 Operating Characteristics 73 Delay Curves 74 Specifications 75 Decision Tables

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

Solenoid Locking Safety Switches

Solenoid Locking Safety Switches Locking Safety Switches HSE HSE Full Size Locking Switches Key features: Plastic Housing: Lightweight 00N locking retention force Available with a red or green indicator Choose from circuit configurations

More information

HS1C-P Interlock Plug Unit with Door Lock

HS1C-P Interlock Plug Unit with Door Lock HSC-P Unit with Lock Interlock plugs with door lock mechanism for high level safety management. Installing the actuator on the guard door and the interlock switch on the machine, the guard door can be

More information

Power Supplies. Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies

Power Supplies. Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies Standard Series Standard Series Switching Part Numbers Part Number Item Watts Rated Voltage Rated Current -A V DC 1.A -A 7. V DC.6A -A24 24V DC.3A -B V DC 2.A Key features of the standard series include:

More information

6mm Interface Relays RV8 Series

6mm Interface Relays RV8 Series 6mm Interface Relays RV8 Series PRODUCT DESCRIPTION Electromechanical C1D2 (screw terminal) Solid State (spring clamp) IDEC 6mm interface relays provide a compact solution for general purpose relay requirements.

More information

Catalog Issued 3-03 (PDF Rev )

Catalog Issued 3-03 (PDF Rev ) W6/W9 series Magnetic Hydraulic P& Circuit reakers Features Designed for the international market. UL Recognized (UL77 and UL5), CS ccepted and VDE approved. Ratings to 5 amps. Heavy duty #-32 stud connections.

More information

INDIVIDUAL CATALOG08 from D&C CATALOG 20th Edition

INDIVIDUAL CATALOG08 from D&C CATALOG 20th Edition CP-F type Circuit protectors CP-P type Circuit protectors CP-B type Circuit protectors CIRCUIT PROTECTORS CP-V type Circuit protectors LOW VOLTAGE CURRENT - LIMITING FUSES AFaC and BaC types HRC fuses

More information

F-Series. Circuit Breaker

F-Series. Circuit Breaker F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic

More information

HS5D Miniature Interlock Switches

HS5D Miniature Interlock Switches Head removal detection for safer performance. Head removal detection function turns OFF the main circuit (-) when the head of the is removed. The is the same size as contact interlock switches (HS5B).

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

HS2B N B - R. Door Interlock Switches. HS2B Series. Full Size Interlock Switch. Part Number. HS2B features: Part Number Key.

HS2B N B - R. Door Interlock Switches. HS2B Series. Full Size Interlock Switch. Part Number. HS2B features: Part Number Key. HSB Series HSB Series Full Size Interlock Switch HSB features: Body Direct Opening Action: If the door is forced open, the contacts are disconnected even if they are welded or stuck Available with or without

More information

PDR circuit breaker - Ground fault Datasheet

PDR circuit breaker - Ground fault Datasheet - Ground fault Datasheet protection device Features Blue housing 1-3 poles plus neutral 7-100mA Preciese, temperature independent operation Choise of time delays, terminals and actuator colours Application

More information

Standard Interlock Safety Switches

Standard Interlock Safety Switches Subminiature Only 78 x 30 x 1m Two actuator entrances provide flexibility for installation options Integrated molded cable reduces wiring time IP67 (IEC60529) Direct Opening Action Actuators comply with

More information

F-Series. Circuit Breaker

F-Series. Circuit Breaker F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic

More information

Ktec Contactors and thermal overloads

Ktec Contactors and thermal overloads Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America

More information

Power Supplies. PS6R Series Switching Power Supplies. Expandable and space-saving switching power supplies. High efficiency reduces operation costs.

Power Supplies. PS6R Series Switching Power Supplies. Expandable and space-saving switching power supplies. High efficiency reduces operation costs. Switching Expandable and space-saving switching power supplies. High efficiency reduces operation costs. 93% efficiency Plug-in output modules for additional output voltages Plug-in branch terminal module

More information

Output Current Input Current Over Voltage. VDC VDC ma ma(typ.) ma(typ.) VDC μf % MKZI10-24S

Output Current Input Current Over Voltage. VDC VDC ma ma(typ.) ma(typ.) VDC μf % MKZI10-24S Doc. E-92 MKZI1 SERIES D/D ONVERTER 1W, Reinforced Insulation, Railway ertified FEATURES Industrial Standard 2" 1" Package Ultra-wide Input Range 9-36VD, 18-75VD, -1VD I/O Isolation 3VA with Reinforced

More information

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics... 4 6. Compliance - Approvals... 6 7. Curves... 7 8. Auxiliares and

More information

Solenoid Locking Safety Switches

Solenoid Locking Safety Switches HSC HSC Full Size Solenoid Locking Switches Key features: Rugged aluminum die-cast housing 00N locking retention force Flexible Installation: The actuator can be accessed from two directions Select from

More information

Relays & Sockets. RQ Series PCB Relays

Relays & Sockets. RQ Series PCB Relays RQ RQ Series PCB Relays IDEC RQ relays are low-profile, PCB relays in a compact package. Size equals value. RQ relays are small, yet maintain high contact ratings and long operational life. For larger

More information

Sealed type washable 1C H-1C-C 812H-1C-V 812H-1C-S (SPDT) F 812H-1C-C F 812H-1C-V F 812H-1C-S F

Sealed type washable 1C H-1C-C 812H-1C-V 812H-1C-S (SPDT) F 812H-1C-C F 812H-1C-V F 812H-1C-S F 8H Type List 8H Terminal style Contact form Features Miniature PCB Power Relays A 2VAC. High CTI 2 material or product comply with IEC 33-1 are available. UL Insulation Class F. VDE, UL/CUL, TUV, CSA/CUS

More information

Miniature Switches & Pilot Devices

Miniature Switches & Pilot Devices A8 Series Miniature Switches and Pilot Devices: 8mm Key features of the 21/64" (8mm) A8 series Switches and Pilot Devices include: 21/64" (8mm) round mounting hole Compact Design Saves Space Bright and

More information

General Specifications

General Specifications Series FB & SB Momentary Pushbuttons General Specifications FB Series Electrical apacity (Resistive Load) Power Level: 500mA @ 125V A for silver Logic Level: 0.4VA max. @ 28V A/D max. for gold (Applicable

More information

HL (AZH) LIMIT SWITCHES

HL (AZH) LIMIT SWITCHES COMPACT SIZE LIMIT SWITCHES LIMIT SWITCHES U L PRODUCT TYPE 1. Limit Switches Actuator Type Push plunger Roller plunger Cross roller plunger Panel mount push plunger Panel mount roller plunger Panel mount

More information

UMBW-UL489 and UL1077 Listed

UMBW-UL489 and UL1077 Listed -UL489 and UL77 Listed Introducing the New WEG Series Thermal-Magnetic Miniature Breakers. This new offering includes both UL489 and UL77 approvals to provide a solution for circuit & equipment protection

More information

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key. HSB Series HSB Series Full Size Interlock Switch HSB features: Body Rugged aluminum die-cast housing Direct Opening Action: If the door is forced open, the contacts are disconnected even if they are welded

More information

General Specifications

General Specifications Series D Light Touch Miniature Pushbuttons General Specifications Electrical apacity (Resistive Load) Logic Level: 0.VA maximum @ 8V A/D maximum (Applicable Range 0.mA ~ 0.A @ 0mV ~ 8V) Note: Find additional

More information

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2 Solid-state Contactor (New Heat Sink Construction) G3PB Space and working time saved with new heat sink construction. Series now includes 480-VAC models to allow use in a greater range of applications.

More information

HS1E-K Interlock Switches with Solenoid (3-circuit)

HS1E-K Interlock Switches with Solenoid (3-circuit) HS1E-K Interlock Switches with Solenoid (-circuit) Dual main circuit + lock monitor circuit provide more safety to your system Basic unit and solenoid unit in one housing Lightweight plastic housing All

More information

Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies Part Numbers

Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies Part Numbers Standard Series Key features: Wide power range: 7.W-4W Universal input : 7.W-W: 8-264V /1-37V DC W: 8-2V /17-264V 24-37V DC (selectable) W, W, 24W: 8-264V /11-3V DC 4W: 3 phase: 32- V 3 phase: 3- V Overcurrent/overvoltage

More information