Low Voltage. EasyPact TVS. Motor starters from 6A to 630A. Catalog 2015

Size: px
Start display at page:

Download "Low Voltage. EasyPact TVS. Motor starters from 6A to 630A. Catalog 2015"

Transcription

1 Low Voltage EasyPact TVS Motor starters from 6A to 630A Catalog 2015

2 Designed for the essential

3 EasyPact TVS General contents EasyPact TVS contactors, 6 A to 630 A A-1 EasyPact TVS thermal overload relays 0.1 A to 630 A B-1 EasyPact TVS control relays 4 NO/NC contacts C-1 EasyPact TVS motor protection circuit breaker 0.1A to 32A D-1 Coordination between protection and control components E-1 1

4 EasyPact TVS: control, protection & Leader in the motor starter market for more than 90 years, Schneider Electric has designed EasyPact TVS range to provide you with the easy solutions you were expecting. EasyPact TVS motor starter and switching solution is the easy choice for simplicity and flexibility. A cost-effective offer > The best price for the performance and quality level you need. > A maximum of solutions with an optimal number of products. > Designed to perform the essential starter's functions: control and overload protection. Simple and intuitive > Easy to install. > Covering 80 % of applications. > With the key accessories to easily build lots of Do-It-Yourself solutions. > With an intuitive commercial references system: easy to order, easy to understand and easy to remember. Guaranteed availability > Available in distribution. > EasyPact TVS fully benefits from Schneider Electric world wide policies: in terms of standards of production, distribution, quality, availability, services and after-sales support. 2

5 switching in a simple way 2 principles to build your starter solution 3-components solution (Magnetic circuit breaker or fuse + Contactor + TOR) 2-components solution (Thermal-magnetic circuit breaker + Contactor) Power and motor protection Power protection or or Tesys GS Tesys GV EasyPact TVS offer Motor control & protection Tesys GV EasyPact TVS offer GZ1 E Motor control 3

6 EasyPact TVS Motor starters, contactors & relays up to 630 A EasyPact TVS: contactors CPB CPB > EasyPact TVS contactors, 6 A to 630 A PB106702_34 > EasyPact TVS thermal overload relays 0.1 A to 630 A CPB > EasyPact TVS control relays 4 NO/NC contacts CPB > EasyPact TVS motor protection circuit breaker 0.1A to 32A > Coordination between protection and control components > Glossary, definitions, technical information 4

7 and relays Control your motors, Do It Yourself simply your solution: direct-on-line starter, reversing starter, star-delta starter 3 pole & 4 pole Characteristics A-1 Accessories, spare parts A-19 Dimensions, mounting A-29 Footprint for complete compatibility with contactors (direct mounting under contactors) Characteristics B-1 Dimensions, mounting B-7 Pilot your control circuits Characteristics C-1 Dimensions, mounting C-4 Better continuity of service What Characteristics coordination means 46 D-1 Glossary 49 References D-3 Definitions 50 Technical Dimensions, informations mounting 51 D-7 Better continuity of service What coordination means E-1 Glossary E-5 Definitions E-6 Technical informations E-7 5

8 EasyPact TVS Motor starters, contactors & relays up to 630 A EasyPact TVS 3-pole contactors CPB CPB CPB Size Rated operational current AC-3 A Rated operational current AC-1 A Rated operational power in AC-3 220/230 V /400 V /440 V kw / V /690 V Width mm Coil rated operating voltage V AC according to the coil voltage code (see below) Auxiliary built in contact 1 NO or 1 NC 1 NO + 1 NC References (1) LC1E06 LC1E09 LC1E12 LC1E18 LC1E25 LC1E32 LC1E38 LC1E40 LC1E50 LC1E65 (1) Partial, see below. Coil voltage code for 3-pole contactors LC1E Hz B5 E5 F5 M5 - U5 Q5 N5 R5 60 Hz B6 - F6 M6 - - Q6 - R6 LC1E /60Hz B7 E7 F7 M7 P7 - Q7 - - LC1E /60Hz - E7 F7 M7 - U7 Q7 N7 R7 Contactor: how to determine the full commercial reference? Example: LC1E U 5 ref. LC1E1210U Hz Coil voltage code Auxiliary contact configuration (2) Rated operation current AC3 Contactor 240 V 01 1NC 10 1NO 12 A EasyPact TVS Example 1: you need a 32 A contactor, 1 NC auxiliary contact, 24 V - 50 Hz coil C LC1E3201B5 Example 2: you need a 120 A contactor, 1 NC + NO auxiliary contact, 220 V - 50 Hz coil C LC1E120M5 (2) Example up to LC1E38 For details, please consult page A-3. A-1

9 from 6 to 630 A CPB CPB CPB CPB CPB / / / / NO + 1 NC - - LC1E80 LC1E95 LC1E120 LC1E160 LC1E200 LC1E250 LC1E300 LC1E400 LC1E500 LC1E630 Common characteristics > Contactors compatible with: LAENp auxiliary contact blocks (see page A-20) LAETSD time delay auxiliary contact (from 25 A contactor) (see page A-20) LAERCpp RC switch suppressor (up to 95 A) (see page A-19) LAEMp mechanical interlock (see page A-19) LAEPp set of power connections (up to 95 A) (see page A-19) Utilisation categories > Class AC-1: AC loads with cos j at least equal to 0.95 (resistive load, heating, distribution, etc.). > Class AC-3: squirrel-cage motors with breaking taking place with the motor running. A-2

10 EasyPact TVS Motor starters, contactors & relays up to 630 A Commercial reference numbering system LC1E p p p p p p p p Frequency Code 50 Hz 5 60 Hz 6 50/60 Hz 7 Coil voltage (1) Code 24 V B 48 V E 110 V F 220 V M 230 V P 240 V U 380 V Q 400 V V 415 V N 440 V R (1) For 3-pole contactors, please refer to page A-1. For 4-pole contactors, please refer to page A-4. Rated operation current (AC3) Auxiliary contact configuration Code EasyPact TVS 3-pole NO (or 1 NC) 10 (or 01) NO+1NC none no auxiliary contact none Rated operation Main contact Code current (AC3) EasyPact TVS 4-pole NO NO + 2 NC 008 Rated operation current (AC3) Code EasyPact TVS 3-pole EasyPact TVS 4-pole Type Contactor Designation EasyPact TVS Contactor: how to determine the full commercial reference? Example 1: you need a 32 A contactor, 1 NC auxiliary contact, 24 V - 50 Hz coil C LC1E3201B5 Example 2: you need a 120 A contactor, 1 NC + NO auxiliary contact, 220 V - 50 Hz coil C LC1E120M5 A-3

11 EasyPact TVS 4-pole contactors from 6 to 95 A CPB CPB CPB CPB Size Rated operational current AC-3 A Rated operational current AC-1 A Width mm Coil rated operating voltage V AC according to the coil voltage code (see below) Auxiliary built in contact no built in contact References (1) LC1E06 LC1E09 LC1E12 LC1E18 LC1E25 LC1E32 LC1E38 LC1E40 LC1E65 LC1E80 LC1E95 (1) Partial, see below. Coil voltage code for 4-pole contactors LC1E /60Hz B7 E7 F7 M7 P7 U7 Q7 V7 N7 Common characteristics > Contactors compatible with: LAENp auxiliary contact blocks (see page A-20) LAETSD time delay auxiliary contact (from 25 A contactor) (see page A-20) LAERCpp RC switch suppressor (up to 95 A) (see page A-19) Contactor: how to determine the full commercial reference? Example: LC1E B 7 ref. LC1E12004B7 7 50/60Hz Coil voltage code Main Contact Rated operation current AC3 Contactor 24V 004 4NO 008 2NO+2NC 12 A EasyPact TVS Example 1: you need a 32 A contactor, 4 NO contact, 24 V - 50/60Hz coil C LC1E32004B7 Example 2: you need a 95A contactor, 2NO+2NC contact, 220 V - 50/60Hz coil C LC1E95008M7 A-4

12 Characteristics EasyPact TVS 3-pole contactors 6 to 630 A Power characteristics Power circuit connections Contactor type LC1E06 LC1E09 LC1E12 LC1E18 Number of poles 3 Rated operational In AC-3 (q 60 C) A current (Ie) (Ue 440 V) In AC-3 (q 55 C) In AC-1 (q 60 C) In AC-1 (q 40 C) Rated operational voltage (Ue) Up to V 690 Frequency limits Of the operational current Hz 50 or 60 Conventional thermal current (Ith) q 60 C A q 40 C Rated breaking capacity at 440 V Conforming to IEC A Rated making capacity at 440 V Conforming to A IEC Permissible short time rating 10 s A No current flowing for preceding 15 minutes with q 40 C 1 min min Maximum permissive current No current flowing for previous 60 minutes, at q 40 C For 10 s A Protection by fuses against short-circuits Without thermal overload relay gg fuse Type 1 A (U 690 V) With thermal overload relay For corresponding am or gg fuse ratings corresponding to the associated LREp thermal overload relay, please see page B-3 Average impedance per pole At Ith and 50 Hz mω 2.5 Power dissipation per pole for the above operational AC-3 W currents AC Electrical durability AC-3 (Ue 440 V) Million AC-1 (Ue 440 V) cycles Mechanical durability 10 Power circuit connections Connection maximum c.s.a. Flexible cable with cable end 1 conductor mm conductors Solid cable without cable end 1 conductor mm conductors Cable with lug mm Bar Number of bars Bar mm x mm Bolt diameter 1 conductor mm Tightening torque Power circuit connection N.m 1.2 Tool Philips N 2 or Ø6mm flat A-5

13 LC1E25 LC1E32 LC1E38 LC1E40 LC1E50 LC1E65 LC1E80 LC1E95 LC1E120 LC1E160 LC1E200 LC1E250 LC1E300 LC1E400 LC1E500 LC1E / x x x 25 4 x 32 5 x x 5 40 x 5 60 x 5 M8 M10 M Ø8mm flat Ø8mm flat or Allen Allen key n 4 Wrench key n 4 A-6

14 Characteristics EasyPact TVS 4-pole contactors 6 to 95 A Power characteristics Power circuit connections Contactor type LC1E06 LC1E09 LC1E12 LC1E18 Number of poles 4 Rated operational In AC-3 (q 60 C) A current (Ie) (Ue 415 V) In AC-1 (q 60 C) Rated operational voltage (Ue) Up to V 690 Frequency limits Of the operational current Hz 50/60 Conventional thermal current (Ith) q 60 C A Rated breaking capacity at 440 V Conforming to IEC A Rated making capacity at 440 V Conforming to A IEC Permissible short time rating 10 s A No current flowing for preceding 15 minutes with q 40 C 1 min min Maximum permissive current No current flowing for previous 60 minutes, at q 40 C For 10 s A Protection by fuses against short-circuits Without thermal overload relay gg fuse Type 1 A (U 690 V) With thermal overload relay For corresponding am or gg fuse ratings corresponding to the associated LREp thermal overload relay, please see page B-3 Average impedance per pole At Ith and 50 Hz mω 2.5 Power dissipation per pole for the above operational currents AC-1 W Electrical durability AC-1 (Ue 440 V) Million cycles Mechanical durability 10 Power circuit connections Connection maximum c.s.a. Flexible cable with cable end 1 conductor mm conductors Solid cable without cable end 1 conductor mm conductors Cable with lug mm Bar Number of bars Bar mm x mm Bolt diameter 1 conductor mm Tightening torque Power circuit connection N.m 1.2 Tool Philips N 2 or Ø6mm flat A-7

15 LC1E25 LC1E32 LC1E38 LC1E40 LC1E65 LC1E80 LC1E Ø8mm flat Ø8mm flat or Allen key n 4 A-8

16 Characteristics EasyPact TVS 3-pole contactors 6 to 630 A Control circuit: coil characteristics Built in auxiliary contact Control circuit: coil characteristics with a.c. supply Contactor type LC1E06 LC1E09 LC1E12 LC1E18 Rated control circuit voltage (Uc) 50/60 Hz V according coil voltage code Control voltage limits (q 55 C) 50 Hz or 60 Hz coils Operational Uc Average consumption at 20 C and at Uc Drop-out a 50 Hz coils Inrush coil VA 95 cos ϕ 0.75 Sealed coil VA 8.5 cos ϕ 0.3 a 60 Hz coils Inrush coil VA 95 cos ϕ 0.75 Sealed coil VA 8.5 cos ϕ 0.3 Heat dissipation W Uc Operating time Closing "C" ms Maximum operating rate at ambiant temperature 60 C Maximum operating rate at ambiant temperature 55 C Control circuit connections Connection maximum c.s.a. Flexible cable without cable end Flexible cable with cable end Solid cable without cable end Opening "O" In operating 1800 cycles per hour 1 or 2 conductors mm conductor mm conductors or 2 conductors mm Tightening torque N.m 1.2 Screwdriver Philips N 2 - Ø6 mm flat Built in auxiliary contact Contacts conforming to IEC LC1E06...E38: contactor's own 1NO or 1NC LC1E40...E160: contactor's own 1NO and 1NC Rated operational voltage (Ue) Up to V 690 Rated insulation voltage (Ui) Conforming to IEC Conventional thermal current (Ith) Ambient air temperature 60 C A 10 Operating current frequency Hz 50 or 60 Minimum switching capacity U min V 17 l = 10-8 I min ma 5 Short-circuit protection Conforming to IEC gg fuse: 10 A Raked making capacity Conforming to IEC A a: 140 Short-time rating Permissible for 1 s A ms ms 140 Insulation resistance MΩ >10 Non-overlap time Guaranteed between N/C and N/O contacts ms 1.5 on energisation and on de-energisation A-9

17 LC1E25 LC1E32 LC1E38 LC1E40 LC1E50 LC1E65 LC1E80 LC1E95 LC1E120 LC1E160 LC1E200 LC1E250 LC1E300 LC1E400 LC1E500 LC1E according coil voltage code Uc Uc Uc Uc /60 A-10

18 Characteristics EasyPact TVS 4-pole contactors 6 to 95 A Control circuit: coil characteristics Built in auxiliary contact Control circuit: coil characteristics with a.c. supply Contactor type LC1E06 LC1E09 LC1E12 LC1E18 Rated control circuit voltage (Uc) 50/60 Hz V according coil voltage code Control voltage limits (q 55 C) 50/60 Hz coils Operational Uc Average consumption at 20 C and at Uc Drop-out a 50 Hz coils Inrush coil VA 95 cos ϕ 0.75 Sealed coil VA 8.5 cos ϕ 0.3 a 60 Hz coils Inrush coil VA 95 cos ϕ 0.75 Sealed coil VA 8.5 cos ϕ 0.3 Heat dissipation W Uc Operating time Closing "C" ms Maximum operating rate at ambiant temperature 60 C Maximum operating rate at ambiant temperature 55 C Control circuit connections Connection maximum c.s.a. Flexible cable without cable end Flexible cable with cable end Solid cable without cable end Opening "O" In operating 1800 cycles per hour 1 or 2 conductors mm conductor mm conductors or 2 conductors mm Tightening torque N.m 1.2 Screwdriver Philips N 2 - Ø6 mm flat A-11

19 LC1E25 LC1E32 LC1E38 LC1E40 LC1E65 LC1E80 LC1E A-12

20 90 90 Characteristics EasyPact TVS 3-pole contactors 6 to 630 A Environment Contactor type LC1E06...E18 LC1E25...E38 Rated insulation voltage (Ui) Conforming to IEC , overvoltage category III, degree of pollution: 3 V 690 Rated impulse withstand voltage (Uimp) Conforming to IEC kv 6 Conforming to standards IEC , IEC Product certifications EAC Degree of protection (front face only) Conforming to IEC Protection against direct finger contact IP2X Protective treatment Conforming to IEC "TH" Ambiant air temperature Storage C around the device Operation Permissible at UC (2) Maximum operating altitude Without derating m 3000 Operating positions Without derating ±30 in relation to normal vertical mounting plane 180 Flame resistance Conforming to IEC C 850 C Shock resistance (3) Contactor open 7 gn 6 gn 1/2 sinewave = 11 ms Contactor closed 10 gn Vibration resistance (3) Contactor open 1.5 gn Hz Contactor closed 3 gn (1) Derating, please call your regional sales. (2) Derating see page E-4. (3) Without change of contact states, in the most unfavorable direction (coil energised at Ue). Installation recommandations Avoid fire, product damage or power loss with a safe enclosure Severe conditions such as dust, humidity, high temperature can result in people or equipments exposed to serious risks if the suitable protection of the electrical components is not taken. Spacial CRN steel enclosures is one of our solutions A complete offer with 39 dimensions from 200 x 200 x 150 mm to 1000 x 800 x 300 mm: b with plain door, without plain mounting plate b with plain door and plain mounting plate b with glazed door, without plain mounting plate. b Degree of protection IP 66. b Compliance with standard IEC b A wide range of accessories to fit to all your applications. Spacial CRN, suitable for any application Indoors with harsh and dirty environments like machines, manufacturing plants, and logistic centers. Specific optional devices re-enforce the protection: fans, filters. A-13

21 90 LC1E40...E65 LC1E80...E95 LC1E120...E160 LC1E200...E300 LC1E400 LC1E500 LC1E630 8 IEC IP gn 9gn 6gn 7 gn 15gn 1.5gn 2gn 5gn 4gn A-14

22 90 90 Characteristics EasyPact TVS 4-pole contactors 6 to 95 A Environment Contactor type LC1E06...E18 LC1E25...E38 Rated insulation voltage (Ui) Conforming to IEC , overvoltage category III, degree of pollution: 3 V 690 Rated impulse withstand voltage (Uimp) Conforming to IEC kv 6 Conforming to standards IEC , IEC Product certifications EAC Degree of protection (front face only) Conforming to IEC Protection against direct finger contact IP2X Protective treatment Conforming to IEC "TH" Ambiant air temperature Storage C around the device Operation Permissible at UC (2) Maximum operating altitude Without derating m 3000 Operating positions Without derating ±30 in relation to normal vertical mounting plane 180 Flame resistance Conforming to IEC C 850 C Shock resistance (3) Contactor open 7 gn 6 gn 1/2 sinewave = 11 ms Contactor closed 10 gn Vibration resistance (3) Contactor open 1.5 gn Hz Contactor closed 3 gn (1) Derating, please call your regional sales. (2) Derating see page E-4. (3) Without change of contact states, in the most unfavorable direction (coil energised at Ue). Installation recommandations Avoid fire, product damage or power loss with a safe enclosure Severe conditions such as dust, humidity, high temperature can result in people or equipments exposed to serious risks if the suitable protection of the electrical components is not taken. Spacial CRN steel enclosures is one of our solutions A complete offer with 39 dimensions from 200 x 200 x 150 mm to 1000 x 800 x 300 mm: b with plain door, without plain mounting plate b with plain door and plain mounting plate b with glazed door, without plain mounting plate. b Degree of protection IP 66. b Compliance with standard IEC b A wide range of accessories to fit to all your applications. Spacial CRN, suitable for any application Indoors with harsh and dirty environments like machines, manufacturing plants, and logistic centers. Specific optional devices re-enforce the protection: fans, filters. A-15

23 LC1E40...E65 LC1E80...E95 7 gn A-16

24 Characteristics EasyPact TVS 3-pole contactors EasyPact TVS contactors for motor control up to 335 kw at 400 V, in category AC-3 CPB CPB CPB CPB LC1E06 LC1E65 LC1E120 LC1E300 3-pole contactors Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 Rated operational current in AC V up to Instantaneous auxiliary contacts Basic reference, to be completed by adding the control voltage code Weight 220 V 380 V 415V 660V 230 V 400 V 440V 500 V 690 V Fixing (1) kw kw kw kw kw A kg Connection by screw clamp terminals LC1E0610pp LC1E0601pp LC1E0910pp LC1E0901pp LC1E1210pp LC1E1201pp LC1E1810pp LC1E1801pp LC1E2510pp LC1E2501pp LC1E3210pp LC1E3201pp LC1E3810pp LC1E3801pp LC1E40pp / LC1E50pp LC1E65pp LC1E80pp LC1E95pp LC1E120pp LC1E160pp Connection by bars LC1E200pp LC1E250pp / LC1E300pp / LC1E400pp / LC1E500pp / LC1E630pp 18.6 Coil voltage code for 3-pole contactors LC1E Hz B5 E5 F5 M5 - U5 Q5 N5 R5 60 Hz B6 - F6 M6 - - Q6 - R6 LC1E /60Hz B7 E7 F7 M7 P7 - Q7 - - LC1E /60Hz - E7 F7 M7 - U7 Q7 N7 R7 Seperate components Auxiliary contact blocks, add-on modules and accessories, see pages A-20 to A-21. Coil spare parts For maintenance, each coil can be ordered separatly, see page A-22 to A-26. (1) LC1E06 to E65: clip-on mounting on 35 mm 5 rail AM1 DP or screw fixing. LC1E80 to E95: clip-on mounting on 35 mm 5 rail AM1DP or 75 mm 5 rail AM1 DL or screw fixing. LC1E120 and E160: clip-on mounting on 2 x 35 mm 5 rail AM1 DP or screw fixing. A-17

25 EasyPact TVS 4-pole contactors EasyPact TVS contactors for motor control in category AC-1, 16 to 125A CPB CPB LC1E06 LC1E65 4-pole contactors Non inductive loads maximum current (Ɵ 55 C) utilisation category AC-1 number of poles Basic reference, to be completed by adding the controy voltage code(1) Fixing(1) weight (3) kg LC1E06004pp LC1E06008pp LC1E09004pp LC1E09008pp LC1E12004pp LC1E12008pp LC1E18004pp LC1E18008pp LC1E25004pp LC1E25008pp LC1E32004pp LC1E32008pp LC1E38004pp LC1E38008pp LC1E40004pp LC1E40008pp LC1E65004pp LC1E65008pp LC1E80004pp LC1E80008pp LC1E95004pp LC1E95008pp 1.60 Control voltage code Volts LC1E /60 Hz B7 E7 F7 M7 P7 U7 Q7 V7 N7 Seperate components Auxiliary contact blocks, add-on modules and accessories, see pages A-20 to A-21. Coil spare parts For maintenance, each coil can be ordered separatly, please check with schneider electric. (1) LC1E06 to E38: clip-on mounting on 35 mm 5 rail AM1 DP or screw fixing. LC1E40 to E95: clip-on mounting on 35 mm 5 rail AM1DP or 75 mm 5 rail AM1 DL or screw fixing. A-18

26 Characteristics EasyPact TVS contactors 3-pole/4-pole Accessories for LC1E contactor 3-pole accessories for LC1E contactor LAEM1 LAEP3 LAEP4 Accessories for motor reverse assembly Contactors with screw clamp terminals Using 2 identical contactors Set of power connections Mechanical interlock Cat. no. Weight kg Cat. no. Weight kg Mechanical interlock LC1E06...E12 LAEP LAEM LC1E18/E25 LAEP LAEM LC1E32/E38 LAEP LAEM LC1E40...E65 LAEP LAEM LC1E80/E95 LAEP LAEM LC1E120/E160 (DIY) (1) LAEM LC1E200/E250 (DIY) (1) LAEM LC1E300 (DIY) (1) LAEM LC1E400 (DIY) (1) LAEM LC1E500 (DIY) (1) LAEM LC1E630 (DIY) (1) LAEM (1) DIY : Do It Yourself. 4-pole accessories for LC1E contactor LAEM6/ LAEM7 Accessories for motor reverse assembly Contactors with screw clamp terminals Using 2 identical contactors Mechanical interlock Cat. no. Weight kg Mechanical interlock LC1E06...E12 LAEM LC1E18/E25 LAEM LC1E32/E38 LAEM LC1E40...E65 LAEM LC1E80/E95 LAEM LC1Epp LAERCp RC surge suppressor b Effective protection for circuits highly sensitive to "high frequency" interference and transcient generated when the contactor coil is switched off. For use only in cases where the voltage is virtually sinusoidal, i.e. less than 5 % total harmonic distortion. b Voltage limited to 3 Uc max. and oscillating frequency limited to 400 Hz max. b Slight increase in drop-out time (1.2 to 2 times the normal time). Mounting For use with contactor Cat. no. Weight Rating Type Va kg Screw mounting LC1E06...E LAERCE LAERCG LAERCU LAERCN A-19

27 EasyPact TVS contactors Accessories for LC1E contactor Instantaneous auxiliary contact blocks for connection by screw lamps terminals For use in normal operating environment Clip-on mounting Number of contacts per block Cat. no. Weight kg Front 1 NO / 1 NC LAEN LAEN22 2 NO LAEN NC LAEN NO / 2 NC LAEN Time delay auxiliary contact blocks for connection by screw clamp terminals 8 A V Clip-on mounting Number of contacts per block Time delay Setting range Cat. no. (1) Weight Type kg LAETSD Front 1 NO / 1 NC On-delay s LAETSD (1) For use only LC1E25 to LC1E630. Instantaneous and time delay contact characteristics Contact block type LAEN11, 20, 02, 22 LAETSD Number of contacts 2 or 4 2 Rated operational voltage (Ue) Up to V 690 Rated insulation voltage (Ui) Conforming to IEC Conventional thermal current (Ith) For ambient temperature q 60 C A 8 Minimum switching capacity U min V 17 I min ma 5 Short-circuit protection Conforming to IEC A 10 Rated making capacity Conforming to IEC Irms a 140 Short-time rating Permissible for 1 s A ms ms 140 Insulation resistance mω > 10 Non-overlap time Guaranteed between NC and ms 1.5 (on energisation and on de-energisation) NO contacts Overlap time Guaranteed between LAE N22 N/C and N/O contacts ms Time delay Ambient air temperature for C operation Repeat accuracy ±2 % Drift up to 0.5 million operating cycles +15 % Mechanical durability Rated operational power of contacts (Conforming to IEC ) Drift depending on ambient air temperature In millions of operating cycles 0.25 % per C 10 4 a.c. supply categories AC14/15 V million operating cycles VA million operating cycles million operating cycles A-20

28 Characteristics EasyPact TVS contactors Accessories for LC1E Environment Contact block type LAEN11, 20, 02, 22 LAETSD Conforming to standard IEC Product certifications EAC Protective treatment Conforming to IEC "TH" Degree of protection Conforming to IEC IP2X Ambiant air temperature Storage C Operation Permissible for operation at Uc Maximum operating altitude Without derating m 3000 Connection by cable Philips N 2 and Ø 6 mm. Flexible or solid cable with or without cable end mm 2 Min: 1 x 1 Max: 2 x pole Accessories compatibility Contactor Built in contacts LAENpp LAETSD LAERCp LAEM LAEPp LC1E06 LC1E09 LC1E12 LC1E18 LC1E25 LC1E32 LC1E38 LC1E40 LC1E50 LC1E65 LC1E80 LC1E95 LC1E120 LC1E160 LC1E200 LC1E250 LC1E300 LC1E400 LC1E500 LC1E630 (1) Do It Yourself. 1 NO or 1NC 1 NO + 1NC or 1 2 or 0 1 or DIY (1) 1 4-pole Accessories compatibility Contactor LAENpp LAETSD LAERCp LC1E06 LC1E09 LC1E12 LC1E18 LC1E LC1E32 1 LC1E38 LC1E40 LC1E50 LC1E65 LC1E80 LC1E95 1 or 1 A-21

29 EasyPact TVS 3-poles contactors Coil replacement for EasyPact TVS, LC1E06 to E38 LAEX1pp For 3-pole contactors LC1E06...E18 Specifications Average consumption at 20 C: b inrush (cos ϕ = 0.75) 50 Hz: 95 VA; 60 Hz: 95 VA b sealed (cos ϕ = 0.3) 50 Hz: 8.5 VA; 60 Hz: 8.5 VA Operating range (q 55 C): Uc. Control circuit voltage Uc Average Inductance resistance of closed at 20 C circuit ±10 % Cat. no. (1) Average Inductance resistance of closed at 20 C circuit ±10 % Cat. no. (1) Average Inductance resistance of closed at 20 C circuit ±10 % Cat. no. (1) V Ω H 50 Hz Ω H 60 Hz Ω H 50/60 Hz kg LAEX1B LAEX1B LAEX1B LAEX1E LAEX1E LAEX1F LAEX1F LAEX1F LAEX1M LAEX1M LAEX1M LAEX1P LAEX1U LAEX1Q LAEX1Q LAEX1Q LAEX1N LAEX1R LAEX1R Weight For 3-pole contactors LC1E25 Specifications Average consumption at 20 C: b inrush (cos ϕ = 0.75) 50 Hz: 70 VA; 60 Hz: 70 VA b sealed (cos ϕ = 0.3) 50 Hz: 7 VA; 60 Hz: 7.5 VA Operating range (q 55 C): Uc. Control circuit voltage Uc Average Inductance resistance of closed at 20 C circuit ±10 % Cat. no. (1) Average Inductance resistance of closed at 20 C circuit ±10 % Cat. no. (1) Average Inductance resistance of closed at 20 C circuit ±10 % Cat. no. (1) V Ω H 50 Hz Ω H 60 Hz Ω H 50/60 Hz kg LAEX12B LAEX12B LAEX12B LAEX12E LAEX12E LAEX12F LAEX12F LAEX12F LAEX12M LAEX12M LAEX12M LAEX1P LAEX12U LAEX12Q LAEX12Q LAEX12Q LAEX12N LAEX12R LAEX12R Weight LAEX2pp For 3-pole contactors LC1E32/E38 Specifications Average consumption at 20 C: b inrush (cos ϕ = 0.75) 50 Hz: 70 VA; 60 Hz: 70 VA b sealed (cos ϕ = 0.3) 50 Hz: 7 VA; 60 Hz: 7.5 VA Operating range (q 55 C): Uc. Control circuit voltage Uc Average Inductance resistance of closed at 20 C circuit ±10 % Cat. no. (1) Average Inductance resistance of closed at 20 C circuit ±10 % Cat. no. (1) Average Inductance resistance of closed at 20 C circuit ±10 % Cat. no. (1) V Ω H 50 Hz Ω H 60 Hz Ω H 50/60 Hz kg LAEX2B LAEX2B LAEX2B LAEX2E LAEX2E LAEX2F LAEX2F LAEX2F LAEX2M LAEX2M LAEX2M LAEX1P LAEX2U LAEX2Q LAEX2Q LAEX2Q LAEX2N LAEX2R LAEX2R (1) The last two digits in the reference represent the voltage code. Weight A-22

30 Characteristics EasyPact TVS 3-poles contactors Coil replacement for EasyPact TVS, LC1E40 to E160 For 3-pole contactors LC1E40...E65 Specifications Average consumption at 20 C: b inrush (cos ϕ = 0.75): 50 Hz: 160 VA; 60 Hz: 140 VA b sealed (cos ϕ = 0.3) 50 Hz: 15 VA; 60 Hz: 13 VA Operating range (q 60 C): Uc Control circuit voltage Uc Average Inductance resistance of closed at 20 C circuit ±10 % Cat. no. (1) Average Inductance resistance of closed at 20 C circuit ±10 % Cat. no. (1) Average Inductance resistance of closed at 20 C circuit ±10 % Cat. no. (1) V Ω H 50 Hz Ω H 60 Hz Ω H 50/60 Hz kg Weight LAEX3B LAEX3B LAEX3B LAEX3E LAEX3E LAEX3F LAEX3F LAEX3F LAEX3M LAEX3M LAEX3M LAEX1P LAEX3U LAEX3Q LAEX3Q LAEX3Q LAEX3N LAEX3R LAEX3R For 3-pole contactors LC1E80/E95 Specifications Average consumption at 20 C: b inrush (cos ϕ = 0.75) 50 Hz: 200 VA; 60 Hz: 220 VA b sealed (cos ϕ = 0.3) 50 Hz: 20 VA; 60 Hz: 22 VA Operating range (q 55 C): Uc. Control circuit voltage Uc Average Inductance resistance of closed at 20 C circuit ±10 % Cat. no. (1) Average Inductance resistance of closed at 20 C circuit ±10 % Cat. no. (1) Average Inductance resistance of closed at 20 C circuit ±10 % Cat. no. (1) V Ω H 50 Hz Ω H 60 Hz Ω H 50/60 Hz kg Weight LAEX4pp LAEX4B LAEX4B LAEX4B LAEX4E LAEX4E LAEX4F LAEX4F LAEX4F LAEX4M LAEX4M LAEX4M LAEX1P LAEX4U LAEX4Q LAEX4Q LAEX4Q LAEX4N LAEX4R LAEX4R For 3-pole contactors LC1E120/E160 Specifications Average consumption at 20 C: b inrush (cos ϕ = 0.8) 50 Hz: 300 VA b sealed (cos ϕ = 0.8) 50 Hz: 22 VA Operating range (q 55 C): Uc. Control circuit voltage Uc Average resistance at 20 C ±10 % Inductance of closed circuit Cat. no. (1) Average resistance at 20 C ±10 % Inductance of closed circuit Cat. no. (1) V Ω H 50 Hz Ω H 60 Hz kg Weight LAEX5pp LAEX5B LAEX5B LAEX5E LAEX5F LAEX5F LAEX5M LAEX5M LAEX5U LAEX5Q LAEX5Q LAEX5N LAEX5R LAEX5R (1) The last two digits in the reference represent the voltage code. A-23

31 EasyPact TVS 3-poles contactors Coil replacement for EasyPact TVS, LC1E200 to E300 LAEX6pp For 3-pole contactors LC1E200...E250 Specifications Average consumption at 20 C: b inrush (cos ϕ = 0.9) 50 Hz: 805 VA; 60 Hz: 970 VA b sealed (cos ϕ = 0.3) 50 Hz: 55 VA; 60 Hz: 66 VA Heat dissipation: W. Operating time à Uc: closing = ms, opening = ms. Control circuit voltage Uc Average resistance at 20 C ±10 % Inductance of closed circuit Cat. no. (1) Average resistance at 20 C ±10 % Inductance of closed circuit Cat. no. (1) V Ω H 50 Hz Ω H 60 Hz kg LAEX6B LAEX6B LAEX6E LAEX6F LAEX6F LAEX6M LAEX6M LAEX6U LAEX6Q LAEX6Q LAEX6N LAEX6R LAEX6R Weight LAEX7pp For 3-pole contactors LC1E300 Specifications Average consumption at 20 C: b inrush (cos ϕ = 0.9) 50 Hz or 60 Hz: 650 VA b sealed (cos ϕ = 0.3) 50 Hz or 60 Hz: 10 VA. Heat dissipation: 8 W. Operating time à Uc: closing = ms, opening = ms. Operate on networks with harmonic numbers 7. Operating cycles/hour (q 55 C): 2400 Control circuit voltage Uc Average resistance at 20 C ±10 % Inductance of closed circuit Cat. no. (1) Average resistance at 20 C ±10 % Inductance of closed circuit Cat. no. (1) V Ω H 50 Hz Ω H 60 Hz kg (2) LAEX7B5 20 (2) LAEX7B (2) LAEX7E (2) LAEX7F5 440 (2) LAEX7F (2) LAEX7M (2) LAEX7M (2) LAEX7U (2) LAEX7Q (2) LAEX7Q (2) LAEX7N (2) LAEX7R (2) LAEX7R (1) The last two digits in the reference represent the voltage code. (2) Please consult your Regional Sales Office. Weight A-24

32 Characteristics EasyPact TVS 3-poles contactors Coil replacement for EasyPact TVS, LC1E400 to E630 CDB LAEX8pp For 3-pole contactors LC1E400 (1) Average consumption at 20 C: b inrush (cos ϕ =0.9) 50Hz or 60Hz: b sealed (cos ϕ = 0.9) 50Hz or 60Hz:12 18VA Heat dissipation : 14W Operation time à Uc: closing=40 75ms,opening= ms Operating cycles/hour (q 55 C): 2400 Control circuit voltage Uc Average resistance at 20 C ±10 % Inductance of closed circuit Voltage code V Ω H 50/60Hz kg LAEX8E LAEX8F LAEX8M LAEX8U LAEX8Q LAEX8N7 1 (1) To be commercialized soon, please consult your local Schneider Electric office. Weight CDB CDB LAEX9pp For 3-pole contactors LC1E500 (2) Average consumption at 20 C: b inrush (cosϕ =0.9) 50Hz or 60Hz: A b sealed (cos ϕ = 0.9) 50Hz or 60Hz:16 20VA Heat dissipation : 18W Operation time à Uc: closing=40 75ms,opening= ms Operating cycles/hour (q 55 C): 2400 Control circuit voltage Uc Average resistance at 20 C ±10 % Inductance of closed circuit Voltage code V Ω H 50/60Hz kg LAEX9E LAEX9F LAEX9M LAEX9U LAEX9Q LAEX9N (2) To be commercialized soon, please consult your local Schneider Electric office. Weight A-25

33 EasyPact TVS 3-poles contactors Coil replacement for EasyPact TVS, LC1E400 to E630 CDB LAEX10pp For 3-pole contactors LC1E630 (3) Average consumption at 20 C: b inrush (cosϕ =0.9) 50Hz or 60Hz: VA b sealed (cos ϕ = 0.9) 50Hz or 60Hz:20 25VA Heat dissipation : 20W Operation time à Uc: closing=40 80ms,opening= ms Operating cycles/hour (q 55 C): 1200 Control circuit voltage Uc Average resistance at 20 C ±10 % Inductance of closed circuit Voltage code V Ω H 50/60Hz kg LAEX10E LAEX10F LAEX10M LAEX10U LAEX10Q LAEX10N7 1.5 Weight (3) To be commercialized soon, please consult your local Schneider Electric office. A-26

34 Characteristics EasyPact TVS 4-poles contactors Coil replacement for EasyPact TVS, LC1E06 to E38 LAEX1Tpp For 4-pole contactors LC1E06 E18 Specifications Average consumption at 20 C: b inrush(cos ϕ = 0.75) 50Hz or 60Hz: 95VA b sealed(cos ϕ = 0.3) 50Hz or 60Hz: 8.5VA Heat dissipation: 2.3W Operating time at Uc: closing=12 22ms, opening=4 19ms Operation range(θ 55 C): Uc Control circuit voltage Uc Average resistance at 25 C±10% Inductance of closed circuit Cat.no. Weight V Ω H 50/60Hz kg LAEX1TB LAEX1TE LAEX1TF LAEX1TM LAEX1TP LAEX1TU LAEX1TQ LAEX1TV LAEX1TN LAEX2Tpp For 4-pole contactors LC1E25 E38 Specifications Average consumption at 20 C: b inrush(cos ϕ = 0.75) 50Hz or 60Hz: 95VA b sealed(cos ϕ = 0.3) 50Hz or 60Hz: 8.3VA Heat dissipation: 2.3W Operating time at Uc: closing=12 22ms, opening=4 19ms Operation range(θ 55 C): Uc Control circuit voltage Uc Average resistance at 25 C±10% Inductance of closed circuit Cat.no. Weight V Ω H 50/60Hz kg LAEX2TB LAEX2TE LAEX2TF LAEX2TM LAEX2TP LAEX2TU LAEX2TQ LAEX2TV LAEX2TN A-27

35 EasyPact TVS 4-poles contactors Coil replacement for EasyPact TVS, LC1E40 to E95 LAEX4Tpp For 4-pole contactors LC1E40 E65 Specifications Average consumption at 20 C: b inrush(cos ϕ = 0.75) 50Hz: 160VA; 60Hz: 140VA b sealed(cos ϕ = 0.3) 50Hz: 15VA; 60Hz: 13VA Heat dissipation: 6 10W Operating time at Uc: closing=20 26ms, opening=8 12ms Operation range(θ 55 C): Uc Control circuit voltage Uc Average resistance at 25 C±10% Inductance of closed circuit Cat.no. Weight V Ω H 50/60Hz kg LAEX4TB LAEX4TE LAEX4TF LAEX4TM LAEX4TP LAEX4TU LAEX4TQ LAEX4TV LAEX4TN For 4-pole contactors LC1E80 E95 Specifications Average consumption at 20 C: b inrush(cos ϕ = 0.75) 50Hz: 200VA; 60Hz: 220VA b sealed(cos ϕ = 0.3) 50Hz: 20VA; 60Hz: 22VA Heat dissipation: 6 10W Operating time at Uc: closing=20 35ms, opening=6 20ms Operation range(θ 55 C): Uc Control circuit voltage Uc Average resistance at 25 C±10% Inductance of closed circuit Cat.no. Weight V Ω H 50/60Hz kg LAEX4TB LAEX4TE LAEX4TF LAEX4TM LAEX4TP LAEX4TU LAEX4TQ LAEX4TV LAEX4TN A-28

36 Dimensions and mouting EasyPact TVS 3-pole contactors LC1E06 to E95 LC1E06...E25 LAERCp LC1E32/38 LAERCp 90 c1 c c1 c2 LC1 E06...E18 E25 LC1 E32/38 c c 86 c1 with LAEN c1 with LAEN 120 c2 with LAETSD c2 with LAETSD 138 LC1E06...E25 LC1E32/38 2 x Ø4.8 2 x Ø4.5 2 x Ø /70 C G C G LC1 E06 E09 E12 E18 E25 LC1 E32/38 c c 86 G G 40 LC1E40...E65 LC1E80/95 LAERCp LAERCp c2 c2 LC1 E40...E65 LC1 E80/95 a 75 a 85 b1 with LAERCp 135 b1 with LAERCp 135 c 114 c 121 c1 with LAENp 147 c1 with LAENp 153 c2 with LAETSD 165 c2 with LAETSD 171 LC1E40...E65 LC1E80/ / xØ6,5 40 3xØ6,5 LC1 E40...E65 LC1 E80/95 c 114 c 121 A-29

37 EasyPact TVS 3-pole contactors LC1E06 to E95 2 x LC1E06...E65 with LAEM1 2 x LC1E80/95 with LAEM4 127 LC1 E E E a b c b A-30

38 Dimensions and mouting EasyPact TVS 3-pole contactors LC1E120 and 160 A LC1E120/160 On panel with accessories a 120 c Without add-on blocks 132 c1 With LAEN 150 c2 With LAETSD 168 c c1 c2 a On 2 mounting rails DZ5 MB on 120 mm centres 100 = 158 c (AM1 DP200 or DR200) c (AM1 DE200 or EDppp) 150 = c On Panel 130 = 158 c = G = = LC1E120 LC1E160 c (AM1 DP200 or DR200) G 91/110 96/110 2 x LC1E120 or LC160 with LAEM5 158 e1 130 = c e2 = G = a = 2 x LC1E120 or 160 a c e1 e2 G For 120 and /256 c, e1 and e2: including cabing A-31

39 EasyPact TVS 3-pole contactors LC1E200, E250 and E300 A LC1E200 - LC1E250 - LC1E300 On panel S X1 X1 c L b f Q P P Q1 a fm b1 = = Z = G1 G = Y X1 (mm) = minimum electrical clearence according to operating voltage and breaking capacity V V LC1E LC1E250, a b b1 c f G G1 J J1 L M P Q Q1 S Y Z LC1E LC1E LC1E f = minimum distance required for coil removal. 2 x LC1E200 or LC1E250 with LAEM6-2 x LC1E300 with LAEM7 P1 X1 J X1 J1 c L b1 b J1 = = G1 J a = = G1 J1 110/120 = b = X1 (mm) = minimum electrical clearence according to operating voltage and breaking capacity V V LC1E LC1E250, a b b1 c G1 J J1 L P1 2 x LC1E x LC1E x LC1E A-32

40 Dimensions and mouting EasyPact TVS 3-pole contactors LC1E400, E500 and E630 A LC1E400 - LC1E500 On panel 56 S 44,5 6xM10x35 X1 X1 c L 209 = b = b2 Q P P a Q1 fm G 23,5 G1 J 120 = 180 = = = X1 (mm) minimum electrical clearence according to operating voltage and breaking capacity V V LC1E LC1E a b b2 c f G* Gmin. Gmax. G1* G1min. G1max. J L M P Q Q1 S LC1E LC1E f=minimum distance required for coil removal LC1E xM12x45 X1 X1 280 = 304 = ,5 G J1 = 185 = X1 (mm) = minimum electrical clearence according to operation voltage and breaking capacity V V LC1E (1) Minimum distance required for coil removal Q a Q1 181 (1) a G* G min Gmax. J1 Q Q1 LC1E x LC1E400,LC1E500,LC1E630 P1 X1 (mm) = minimum electrical clearence according to operating voltage and breaking capacity V V LC1E400, LC1E (1) Except LC1 E630 : 4 x Ø (2) Except LC1 E630. X1 X1 c L CDB b1 b J1 J3 (1) G G1 J1 P1 J = J2 = G1 a G G1 J a (1) = 120 (2) = 180 = J1 J3= = G1 J1 = b 110/120 = b = a b b1 c G G1 J J1 J2 J3 L P1 2 x LC1E x LC1E x LC1E A-33

41 EasyPact TVS 4-pole contactors LC1E06...E18 LC1E25...E38 LAERCp LAERCp 90 c1 c2 LC1 E06/E18 LC1 E25/38 c 80 c 93 c1 with LAEN 113 c1 with LAEN 125 c2 with LAETSD 135 c2 with LAETSD 147 c1 c2 LC1E06...E18 2 x Ø4.8 2 x Ø4.5 LC1E25...E38 2 x Ø /70 C G LC1 E06 E09 E12 E18 LC1 E25/38 c c 93 G G 40 C G LC1E40/65 LC1E80/95 LAERCp LAERCp c2 c2 LC1 E40...E65 LC1 E80/95 a 85 a 95 b1 with LAERCp 135 b1 with LAERCp 135 c 110/125 c 120/135 c1 with LAENp 143 c1 with LAENp 160 c2 with LAETSD 165 c2 with LAETSD 172 LC1E40/65 LC1E80/95 100/ / xØ6,5 40 3xØ6,5 LC1 E40/E65 LC1 E80/95 c 114 c 121 A-34

42 Schemes EasyPact TVS contactors LC1E A Contactors (3-pole) LC1E LC1E LC1E120/160 A2 A1 2/T1 1/L1 4/T2 3/L2 6/T3 5/L /NO A2 A1 2/T1 1/L1 4/T2 3/L2 6/T3 5/L /NC LC1E200, 250, 300 LC1E 400,500,630 Contactors (4-pole) LC1E LC1E LC1E A2 2/T1 4/T2 6/T3 8/T4 A2 2 R2 R4 4 A2 R2 2 4 R4 A1 A1 A1 1/L1 3/L2 5/L3 7/L4 1 R1 R3 3 R1 1 3 R3 A2 A1 2/T1 1/L1 4/T2 3/L5 6/T3 5/L3 A1 A /T1 1/L1 4/T2 3/L2 6/T3 5/L3 A2 A1 2/T1 1/L1 4/T2 3/L2 6/T3 5/L /NO 22 21/NC A2 A1 2/T1 1/L1 4/T2 3/L2 6/T3 5/L /NO 22 21/NC A-35

43 EasyPact TVS contactors LC1E A Reversing contactors 2 x LC1E x LC1E Horizontaly mounted 2 x LC1E120, x LC1E200, 250, 300 Horizontaly mounted Front mounting add-on contact blocks 1NO + 1NC (LAEN11) 2NO (LAEN20) 2NC (LAEN02) 2NO +2NC (LAEN22) Time delay auxiliary contacts On delay 1NO + 1NC (LAETSD) 56 55/NC 67/NO 68 KM2 KM1 A1 KM1 A1 KM2 A2 A /NO 62 61/NC 54 53/NO 64 63/NO 52 51/NC 62 61/NC 54 53/NO 62 61/NC 72 71/NC 84 83/NO U V W U V W A2 A /NO 22 21/NC /NO 22 21/NC A2 A1 A2 A A2 A1 L1 L2 L3 L1 L2 L3 U V W U V W A2 A /NC /NC A2 A1 A2 A /NO 22 21/NC /NO 22 21/NC A2 A1 L1 L2 L3 L1 L2 L3 Mechanical interlock LAEMp A-36

44 EasyPact TVS Motor starters, contactors & relays up to 630 A EasyPact TVS thermal TOR Com. Possible Imax Compatible with Contactor (size 1 & 2) Com. Ref. Ref Calibration LC1E06 LC1E09 LC1E12 LC1E18 LC1E25 LC1E32 LC1E38 LRE A b b b b b b b LRE A b b b b b b b LRE A b b b b b b b LRE A b b b b b b b LRE A b b b b b b b LRE A b b b b b b b LRE A b b b b b b b LRE A b b b b b b b LRE A b b b b b b b LRE A b b b b b b LRE A b b b b b b LRE A b b b b b LRE A b b b b LRE A b b b LRE A b b b LRE A b Common characteristics > Class: 10 A. > Operating voltage: max. 690 V AC. B-1

45 overload relays TOR Com. Ref Possible Imax Compatible with Contactor (size 3 & 4) Com. Ref. Calibration LC1E40 LC1E50 LC1E65 LC1E80 LC1E95 LRE A b b b b b LRE A b b b b b LRE A b b b b b LRE A b b b b LRE A b b b LRE A b b LRE A b b LRE A b TOR Com. Ref Possible Imax Calibration Compatible with Contactor (size 5, 6, 7, 8 & 9) Com. Ref. LC1E120 LC1E160 LC1E200 LC1E250 LC1E300 LC1E400 LC1E500 LC1E630 LRE A b b v v v v v v LRE A b b v v v v v v LRE A b b v v v v v v LRE A v b v v v v v LRE A v b b b v v LRE A v b b b v v LRE A b b b v v LRE A b b v v LRE A v b v LRE A v b Note: b means the relay can match with contactor both in electrical and mechanical. v means the relay can match with contactor only in electrical (can not directly mounting). B-2

46 Presentation, description EasyPact TVS thermal overload relays Presentation EasyPact TVS thermal overload relays are designed to protect a.c. circuits and motors against: b overloads b phase failure b Long starting time b prolonged stalled rotor condition. The thermal relay controls permanently the current driven by the motor. When this current exceeds the setting it's auxiliary contacts will change state, causing the motor to stop. Description LREpp, LRE48p 1 Adjustment dial Ir. 2 Test button. Operation of the Test button allows: - checking of control circuit wiring, - simulation of relay tripping (actuates both the N/O and N/C contacts). 3 Stop button. Actuates the N/C contact; does not affect the N/O contact. 4 Reset button. 5 Trip indicator. 6 Setting locked by sealing the cover. 7 Selector for manual or automatic reset. LRE relays are supplied with the selector in the manual position, protected by a cover. Deliberate action is required to move it to the automatic position. 6 2 LRE3pp B-3

47 Characteristics EasyPact TVS thermal overload relays Power circuit characteristics Relay type Ref. LRE LRE LRE LRE LRE LRE 484 LRE LRE 488 Size Tripping class Conforming to IEC A Rated insulation voltage Conforming to IEC V 690 Rated impulse withstand voltage (Uimp) kv 6 Frequency limits Of the operating current Hz Setting range Depending on model A Power circuit connections Connection by screw clamp terminals Minimum/maximum c.s.a. Flexible cable without cable end mm² conductor Flexible cable with cable end conductor Solid cable without cable end 1 conductor Tightening torque N.m Connection by bars or lugs Pitch Without spreaders mm Bars or cables with lugs Cross section - 3X18 3X20 3X25 4X25 5x30 6X40 Screws Type - M8 M8 M10 M10 M10 M12 Tightening torque N.m Auxiliary contact characteristics Conventional thermal current A 5 Max. sealed consumption a.c. supply V of the operating coils of controlled contactors (Occasional operating cycles of contact 95-96) A Protection against shortcircuits Connection by screw clamp terminals Environment By gg, maximum rating or by GB2 A 5 Flexible cable without cable end 1 conductor Flexible cable with cable end 1 conductor Solid cable without cable end 1 conductor Tightening torque N.m 1.7 Minimum/maximum c.s.a. mm² 2 x x x Conforming to standard IEC , IEC Product certifications EAC Degree of protection Conforming to IEC IP2X IP00 Protective treatment Conforming to IEC "TH" Ambiant air temperature Storage C Normal operation without derating (IEC ) Minimum/maximum operating temperature (with derating) (1) Operating positions without derating In relation to normal vertical mounting plane Flame resistance Conforming to IEC C 850 Any position Shock resistance Permissive acceleration 6 gn - 11 ms conforming to IEC Vibration resistance Permissive acceleration 3 gn conforming to IEC Dielectric strenght at 50 Hz Conforming to IEC kv 6 Surge withstand Conforming to IEC Operating characteristics Temperature compensation C Tripping threshold Conforming to IEC A 1.14 ± 0.06 Ir Sensitivity to phase failure Conforming to IEC Tripping current 130 % of Ir on two phase, the last one at 0 (1) Contact your regional sales. LRE 489 B-4

48 Characteristics EasyPact TVS thermal overload relays Tripping curves Average operating time related to multiples of the setting current Time Class 10A x the setting current (Ir) 1 Balanced operation, 3-phase, without prior current flow (cold state). 2 2-phase operation, without prior current flow (cold state). 3 Balanced operation, 3-phase, after a long period at the set current (hot state). B-5

49 EasyPact TVS thermal overload relays 3-pole thermal overload relays Differential thermal overload relays for use with fuses or magnetic circuit-breakers GV2 L and GV3 L b Compensated relays with manual or automatic reset, b with relay trip indicator, b for a.c. LREpp LRE3pp LRE48p Relay setting range (A) Fuses to be used with selected relay am (A) gg (A) For use with contactor LC1 Reference Weight kg Class 10 A (1) for connection by screw clamp terminals E06 E38 LRE E06 E38 LRE E06 E38 LRE E06 E38 LRE E06 E38 LRE E06 E38 LRE E06 E38 LRE E06 E38 LRE E06 E38 LRE E09 E38 LRE E09 E38 LRE E12 E38 LRE E18 E38 LRE E25 E38 LRE E25 E38 LRE E38 LRE E40 E95 LRE E40 E95 LRE E40 E95 LRE E50 E95 LRE E65 E95 LRE E80 E95 LRE E80 E95 LRE E95 LRE Class 10 A (1) directly connected by connector E120...E160 LRE E120...E160 LRE E120...E160 LRE E200 LRE E250...E400 LRE E250...E400 LRE E250...E400 LRE E300...E400 LRE E500 LRE E630 LRE (1) Standard IEC specifies a tripping time for 7.2 times the setting current I R : class 10 A: between 2 and 10 seconds. B-6

50 Dimensions and mounting EasyPact TVS thermal overload relays Direct connection to LRE contactors LRE01...E35 Direct mounting under LC1E contactors with screw clamp connections b LC1Epp With contactor LC1E06...E18 LC1E25 LC1E32/E38 a b c LRE3pp Direct mounting under LC1E contactors with screw clamp connections LC1Epp With contactor on DIN rail AM1-DL201 AM1-DL200 f 7 17 a a LREpp 45 c b e f d LREpp c With contactor LC1E40 LC1E50 LC1E65 LC1E80 LC1E95 a b c d e Electrical diagram all relays Reset Auto Man. Test Auto B-7

51 Connection to a terminal block LRE01...E35 connected to LAEB1 terminal block Independent mounting on 50 mm centres; or on Independent mounting on 110 mm centres rail AM1 DP200 or DE200 LAEB1 LAEB Mounting on DIN rail AM1Dppp Mounting customer back plate LRE322...E365, connected to LAEB3 terminal block Independent mounting on 50 mm centres; or on rail AM1 DP200 or DE200 LAEB3 LAEB3 Mounting on DIN rail AM1Dppp AM1-DP200 AM1-DE200 d B-8

52 Dimensions and mounting EasyPact TVS thermal overload relays Independant mounting and connection LRE48p Independent mounting on mounting plate LRE48p: with direct mounting under contactors LC1E or separate mounting (without accessory). Ø P A A D C G R 4 x Ø 6.5 B T B H S F Q E (mm) Dimensions and mounting Range (A) A B C D E F G H P Q R S T LRE LRE LRE LRE LRE LRE LRE LRE LRE LRE B-9

53 Independant mounting and connection LRE48p Independent mounting on mounting plate LRE48p: with direct mounting. A A C E R B D B H F Dimensions and mounting Range (A) A B C D E F H LRE LRE LRE LRE LRE LRE LRE LRE LRE LRE (mm) B-10

54 Dimensions and mounting EasyPact TVS thermal overload relays Independant mounting and connection CDB Accessories for LRE48X Thermal Overload Relay Relay mounting with Contactor directly Mounting support Relay Contactor cat No. weight (Kg) LRE480 LC1E LAES LRE481 LC1E LAES LRE482 LC1E LAES LRE483 LC1E200 LAES LRE484 LC1E LAES LRE485 LC1E LAES LRE486 LC1E LAES Dimension LAES1 LAES2 10 A (mm) B (mm) C (mm) A H B B-11

55 B-12

56 EasyPact TVS Motor starters, contactors & relays up to 630 A EasyPact TVS control relays CPB CPB CPB Contact configuration Coil V AC/Hz 50 Hz 50 Hz 50 Hz 24 CAE40B5 CAE22B5 CAE31B5 48 CAE40E5 CAE22E5 CAE31E5 110 CAE40F5 CAE22F5 CAE31F5 220 CAE40M5 CAE22M5 CAE31M5 240 CAE40U5 CAE22U5 CAE31U5 380 CAE40Q5 CAE22Q5 CAE31Q5 415 CAE40N5 CAE22N5 CAE31N5 440 CAE40R5 CAE22R5 CAE31R5 Characteristics > 4 NO/NC contacts. > Weight: kg. C-1

57 Characteristics EasyPact TVS control relays Control circuit characteristics Type Rated control circuit voltage (Uc) CAEa V Control voltage limits Operation Coil type: 50 Hz Uc Drop-out Uc Average consumption at 20 C and at Uc a 50 Hz VA Sealed and closed: 70 Maintain: 8 Operating time Between coil opening of the N/C ms (rated control circuit energisation contact voltage, ambient and closing of the N/O temperature 20 C) contact Between coil de-energisation and opening of the N/C contact closing of the N/O contact Momentary supply failure Maximum power-off time without 2 influencing sealed state Maximum operating rate Operating cycles per second 3 Mechanical durability In millions of operating cycles Coil type: 50 Hz 10 Control connection (coil) Connecting to screw clamp terminals Flexible cable 1 conductor mm without cable end 2 conductors Flexible cable 1 conductor with cable end 2 conductors Solid cable 1 conductor without cable end 2 conductors Tightening torque N.m 1.2 Characteristics of built in instantaneous contacts Number of contacts 4 Rated operational voltage Up to V 690 (Ue) Rated insulation voltage (Ui) Conforming to IEC Conventional thermal Operational environment temperature A 10 current (lth) y 40 C Operating current frequency Hz 50 Minimum switching U min V 17 capacity l min ma 5 Short-circuit protection Conforming to IEC A gg fuse: 10 A Rated making capacity Conforming to IEC A a: 140 Short-time rating Permissible for 500 ms A ms 140 Insulation resistance MΩ > 10 Non-overlap time Guaranteed non-overlap between ms 1.5 on energisation and on de-energisation N/C and N/O contacts Tightening torque Philips n 2 N.m 1.2 Non-overlap distance Contact LAENpp connecting with auxiliary contacts Instantaneous contacts connection Connecting to screw clamp terminals Flexible cable 1 conductor mm without cable end 2 conductors Flexible cable 1 conductor with cable end 2 conductors Solid cable 1 conductor without cable end 2 conductors Tightening torque N.m 1.2 C-2

58 Characteristics EasyPact TVS control relays Environment Type Rated insulation voltage (Ui) CAEa Conforming to IEC V 690 Rated impulse withstand Conforming to IEC kv 6 voltage (Uimp) Electrical insulation IEC Up to 400 V reinforced insulation Conforming to standards IEC Certifications EAC Protective treatment Conforming to IEC "TH" Degree of protection Conforming to IEC IP2X Ambient air temperature Storage C around the device UC For operation at Uc Maximum operating altitude Without derating m 3000 Operating position Without derating in the following positions Shock resistance (1) 1/2 sine ware, 11 ms Vibration resistance (1) Hz Control relay open Control relay closed Control relay open Control relay closed 7 gn 10 gn 1.5 gn 3 gn (1) No change of contact state at coil voltage Ue in worst conditions. Rated operational power of contacts ( conforming to IEC ) a.c.supply. categories AC-14 and AC-15 Electrical durability ( valid for up to 3600 operating cycles/hour ) on an inductive load such as the coil of an electromagnet: making current ( cos φ0.7 ) = 10 times the power broken ( cos φ0.4 ). Number of operation cycles AC-14/AC VAC 48 VAC 115 VAC 230 VAC 400 VAC 440 VAC 600 VAC d.c.supply. categories DC-13 Electrical durability ( valid for up to 1200 operating cycles/hour ) on an inductive load such as the coil of an electromagnet, without economy resistor, the time constant increasing with the power. DC VDC 1 million operating cycles VA million operating cycles W million operating cycles VA million operating cycles W million operating cycles VA million operating cycles W VDC 125 VDC 250 VDC 400 VDC CDB Millions of oprating cycles CDB Millions of oprating cycles V V V 125V 250V 48V Current broken in A Current broken in A C-3

59 Mounting dimension EasyPact TVS control relays Control relays and auxiliary blocks CAEpp LAERCp 90 c1 CAE c c1 with LAEN CAE On mounting plate AM1-P 2 x Ø4.8 2 x Ø C G c 80 G 35 CAEa CAE40 CAE31 CAE22 A2 A /NO 24 23/NO 34 33/NO 44 43/NO 14 13/NO 22 21/NC 34 33/NO 44 43/NO 14 13/NO 22 21/NC 32 31/NC 44 43/NO C-4

60 Accessories EasyPact TVS control relays Auxiliary contact blocks RC suppressor CAEppp LAERCp LAENp 2 contacts LAENp 4 contacts Instantaneous auxiliary contact blocks For use in normal operating environments Number of contacts Maximum number of relays that can be mounted Front mounted Side mounted Composition Cat. no. Weight NO NC kg LAEN LAEN LAEN LAEN Coil suppressor modules RC suppressor b Effective protection for circuits highly sensitive to "high frequency" interference and transcient generates when the contactor coil is switched off. For use only in cases where the voltage is virtually sinusoidal, i.e. less than 5 % total harmonic distortion. b Voltage limited to 3 Uc max. and oscillating frequency limited to 400 Hz max. b Slight increase in drop-out time (1.2 to 2 times the normal time). Mounted on Operational voltage Cat. no. Weight kg CAE40pp a V LAERCE a V LAERCU a V LAERCG a V LAERCN C-5

61 C-6

62 Presentation, characteristics Protection components Thermal-magnetic motor circuit-breakers GZ1 E Presentation GZ1 E motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers specifically designed for the control and protection of motors, conforming to standards IEC and IEC Connection These circuit-breakers are designed for connection by screw clamp terminals. This technique ensures secure, permanent and durable clamping that is resistant to harsh environments, vibration and impact and is even more effective when conductors without cable ends are used. Each connection can take two independent conductors. Pushbutton control. Energisation is controlled manually by operating the Start button I 1. De-energisation is controlled manually by operating the Stop button O 2, or automatically by the thermal-magnetic protection elements or by a voltage trip attachment. Protection of motors and personnel Motor protection is provided by the thermal-magnetic protection elements incorporated in the motor circuit-breaker. The magnetic elements (short-circuit protection) have a non-adjustable tripping threshold, which is equal to about 13 times the maximum setting current of the thermal trips. The thermal elements (overload protection) include automatic compensation for ambient temperature variations. The rated operational current of the motor is displayed by means of a graduated knob 3. Personnel protection is also provided. All live parts are protected against direct finger contact. GZ1 E motor circuit-breakers are easily installed in any confi guration thanks to their universal fi xing arrangement: screw fi xing or clip-on mounting on symmetrical, asymmetrical or combination rails. Environment Circuit-breaker type GZ1 E Conforming to standards IEC , IEC Protective treatment TH Degree of protection In GV2 MC01 enclosure: IP 41 In GV2 MC02 enclosure: IP 55 Ambient air temperature Storage C Operation Flame resistance Conforming to IEC C 960 Maximum operating altitude m 2000 Cabling Min. Max. Number of conductors and c.s.a. Solid cable mm 2 2 x 1 2 x 6 Flexible cable without cable end mm 2 2 x x 6 Flexible cable with cable end mm 2 2 x 1 2 x 4 Suitable for isolation Conforming to Yes IEC Tightening torque N.m 1,7 Rated operational voltage Conforming to IEC V 690 (Ue) Rated insulation voltage (Ui) Conforming to IEC V 690 Rated operational frequencyconforming to IEC Hz 50/60 Rated impulse withstand Conforming to IEC kv 6 voltage (U imp) Total power dissipated per W 2.5 pole Mechanical durability C.O (C.O.: closing, opening) Electrical durability For AC-3 duty CF.O Duty class C.O./h 25 (maximum operating rate) D-1

63 Characteristics (continued) Protection components Thermal-magnetic motor circuit-breakers GZ1 E Breaking capacity Circuit-breaker type GZ1 E 01 to to 32 Rating A 0.1 to 1.6 2, to 32 Breaking capacity 230/240 V Icu ka g g g g g g g conforming to IEC Ics % (1) g g g g g g g /415 V Icu ka g g g g g Ics % (1) g g g g g V Icu ka g g g Ics % (1) g g g V Icu ka g g g Ics % (1) g g g V Icu ka g Ics % (1) g g > 100 ka. (1) As % of Icu. Tripping curves Average operating times at 20 C related to multiples of the setting current Time (s) ,1 0,01 0, , x the setting current (Ir) 1 3 poles from cold state 2 2 poles from cold state 3 3 poles from hot state D-2

64 References Protection components Thermal-magnetic motor circuit-breakers GZ1 E CPB GZ1 E Motor circuit-breakers Pushbutton control Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 Setting range of thermal trips Magnetic tripping current Id ± 20 % Reference Weight 230 V 400 V 440 V 500 V 690 V kw kw kw kw kw A A kg GZ1 E GZ1 E GZ1 E GZ1 E GZ1 E GZ1 E GZ1 E GZ1 E GZ1 E GZ1 E GZ1 E GZ1 E GZ1 E , GZ1 E GZ1 E D-3

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30 Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,

More information

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors 90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp

More information

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660 Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

C -5 to +55 (0.8 to 1.1Uc) Permissible o

C -5 to +55 (0.8 to 1.1Uc) Permissible o T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC 60947-4

More information

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com TeSys D, K Catalogue 2017 'S335' series contactors for electrodomestic applications schneider-electric.com Presentation TeSys D, TeSys K TeSys D, TeSys K: S335 series Best-in-class contactors for electrodomestic

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors

5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors Contents 0 - Contactors Selection guides.............................................page /2 b General, selection of contactors....................... pages /16 k contactors and reversing contactors b

More information

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

LR9 F OVERLOAD RELAYS

LR9 F OVERLOAD RELAYS Issued November 2009 DATA SHEET LR9 F OVERLOAD RELAYS Based on Schneider MKTED2050EN Catalogue General 6 Motor protection Operating conditions There are many possible causes of electric motor failure.

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC Product data sheet Characteristics LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 -

More information

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter 3 Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter The easy choice for quality, value, and peace of mind Schneider Electric makes it an easy choice

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

Contactors. d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. References

Contactors. d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. References d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. c Standard power ratings Rated Instantaneous Basic reference. Weight of 3-phase motors operational auxiliary

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC Product datasheet Characteristics LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 -

More information

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition Product datasheet Characteristics LC1F400E7 Complementary [Uimp] rated impulse withstand voltage Overvoltage category [Ith] conventional free air thermal current Main Range Product name Product or component

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC Product datasheet Characteristics LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 -

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France Contact us ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F-69687 Chassieu cedex / France You can find the address of your local sales organisation on

More information

K30H001YP cam star-delta switch - 3-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101428D0201 28/03/11 -.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)

More information

Industrial contactors CTX-1

Industrial contactors CTX-1 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 Industrial contactors /04/05/10/12/14/15/20/22/24/25/30/32/34/35/40/42/44/45 CONTENTS PAGE 1. Use... 1 2. Range... 1 3. Electrical

More information

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Characteristics interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Stock Code: Stock - Normally stocked in distribution facility Price*: 4.20 USD Complementary Shape of pin Jul 8, 2015 Main Commercial

More information

CI-TI Contactors and Motor Starters Type CI 6-50

CI-TI Contactors and Motor Starters Type CI 6-50 Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components

More information

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals NSL..S 4-pole / 8-pole Contactor Relays - Spring DC Operated Description - 1-stack contactor relays: 4-pole, - 2-stack contactor relays: 8-pole, - Mechanically linked contact elements available, - Low

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line 2 Contactores Compactos CWC0 Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors

More information

Contactor Types CI 61-98

Contactor Types CI 61-98 MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories

More information

Star Series Motor protection & control

Star Series Motor protection & control Contact us ABB Inc. Low Voltage Control Products 16250 W. Glendale Drive New Berlin, WI 53151 Phone: 888-385-1221 Fax: 800-726-41 USA Technical support & Customer Service: 888-385-1221, Option 4 7:30AM

More information

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction Introduction Introduction Schneider Electric offers a complete line of products for the manual control and protection of motors. This catalog covers those devices designed to meet IEC standards for protection

More information

K50H004UP cam changeover switch - 4-pole A - screw mounting

K50H004UP cam changeover switch - 4-pole A - screw mounting Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

Ktec Contactors and thermal overloads

Ktec Contactors and thermal overloads Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America

More information

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

Pendant control stations 6

Pendant control stations 6 Characteristics For control circuits Environment Conformity to standards EN/IEC 0-- EN/IEC 00-, UL 0, CSA C- n EN/IEC 0-- and EN/ISO 0: 00 for versions with trigger action Emergency stop Protective treatment

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Auxiliary contact blocks - with spring terminals Accessories

Auxiliary contact blocks - with spring terminals Accessories Auxiliary contact blocks - with spring terminals Accessories CA3-10S 1SBC101037F0014 Description The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits. CA3

More information

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control

More information

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30 Contactors KNL KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30 Adaptable to various control requirements with ability of mounting from one to four additional auxiliary contacts. Versatile product capable

More information

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD. DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN

More information

References 4 Fuse carriers

References 4 Fuse carriers References components 000_ -pole basic blocks Rating Cartridge fuse size umber of early break contacts () Single-phase protection device () Reference () Connection by spring terminals A 0 x 8 () Without

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

RUMC22F7 universal plug-in relay - Zelio RUM - 2 C/O V AC - 10 A - with LED

RUMC22F7 universal plug-in relay - Zelio RUM - 2 C/O V AC - 10 A - with LED Characteristics universal plug-in relay - Zelio RUM - 2 C/O - 120 V AC - 10 A - with LED Product availability : Stock - Normally stocked in distribution facility Price* : 13.79 USD Main Range of product

More information

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description

More information

Controls. CONTACTORS CWB Line (up to 40A)

Controls. CONTACTORS CWB Line (up to 40A) Controls CONTACTORS CWB Line (up to 40A) 0800 367 934 Contactors CWB Line (up to 40A) CONTACTORS CWB Line (up to 40A) Summary New WEG CWB Contactors 4 The Technology Within 6 Energy Savings 7 Easy Panel

More information

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons Characteristics pendant control station XAC-A - 8 pushbuttons Complementary Control station colour Connections - terminals Mechanical durability Cable entry Contact code designation [Ithe] conventional

More information

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5- MKING MODERN LIVING POSSIBLE Technical brochure Minicontactors CI 5- www.danfoss.com 2 IC.PD.C10.F3.02-520B4167 Danfoss /S, C-SMC, mr, 07-2010 Contents Page Minicontactor CI 5- Introduction...............................................................................4

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays New generation of Contactors from LS Industrial Systems Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol

More information

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons Characteristics pendant control station XAC-A - 8 pushbuttons Main Range of product Product or component type Device short name Complementary Control station type Enclosure material Electrical circuit

More information

About us. Switchgear Factory, Mumbai

About us. Switchgear Factory, Mumbai About us Larsen & Toubro is a technologydriven USD 8.5 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering, Construction,

More information

Limit switches 3. Page 92. Page 92

Limit switches 3. Page 92. Page 92 Presentation, general characteristics b XCKS with cable entry v With head for linear movement (plunger) Page v With head for rotary movement (lever) Page Environment characteristics Conformity to standards

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

Application Mini Contactors for Motors and Resistive Loads

Application Mini Contactors for Motors and Resistive Loads Delivery program Contactor, 4p, 4kW/400V/AC3 Part no. DILEM4-G(24VDC) Catalog No. 012701 Eaton Catalog No. XTMF9A00TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads

More information

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A) Controls THERMAL OVERLOAD RELAYS RW..D (up to 0A) 0800 7 9 Thermal Overload Relays RW..D (up to 0A) THERMAL OVERLOAD RELAYS RW..D (up to 0A) Summary Introduction RW7-D Thermal Overload Relay from 0.8 up

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Safety Relay Unit Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Two-pole slim models that are only 22.5 mm wide, three-pole models that are only 68 mm wide,

More information

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators Double insulated, types XCK-P and XCK-T Presentation XCK-P with 1 cable entry, conforming to CENELEC EN 57 With head for linear movement (plunger) operators Page 18 With head for rotary movement (lever)

More information

Mini Contactors CI 4-

Mini Contactors CI 4- Data sheet Mini Contactors CI 4- Introduction CI 4 minicontactors cover the power range 1.5 to 5.9 kw and are available for a.c. and d.c. coil voltages. Characteristic of the minicontactors is that they

More information

Low Voltage Industrial Controls. CWB and RW27-2D. IEC Contactors and Thermal Overload Relays

Low Voltage Industrial Controls. CWB and RW27-2D. IEC Contactors and Thermal Overload Relays CWB and RW27-2D IEC Contactors and Thermal Overload Contactors Overload A-2-800-ASK4WEG www.weg.net/us Contactors CWB CWB Features A-4 Catalog Number Format A-7 Accessories Overview A-8 Part Number List

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx Characteristics limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx Main Range of product OsiSense ATEX D Series name Standard format Product or component type Limit switch Device short name XCKJ

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons Characteristics pendant control station XAC-A - 8 pushbuttons Complementary Control station colour Connections - terminals Mechanical durability Cable entry Contact code designation [Ithe] conventional

More information

Switches Unlimited Phone: * Fax:

Switches Unlimited Phone: * Fax: For Info: sales@switchesunlimited.com www.switchesunlimited.com Phone: 800-1-0487 Fax: 718-67-6370 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings

More information

Contactors and Overload Relays

Contactors and Overload Relays Contactors and Overload Relays Catalogue 2011 2 CONTENT Contactor Introduction...4 Range over view...8 Technical information - CN Series...10 Add on accessories - CN Series...12 Accessory fitment over

More information

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Data sheet CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Description Danfoss contactors CI 6-50 cover the power range 2.2-25 kw. CI 6 is built up as a combined contactor/control relay. CI 9

More information

Square D General Purpose Relays

Square D General Purpose Relays Square D General Purpose Relays Class 0R plug-in relays 0RS (SPDT) 0RS (DPDT) 0RS3 (3PDT) 0RS (PDT) Catalog 0 Contents Class 0R plug-in relays bbspecifications....................................................

More information

Page 2-4 Page 2-8. Page Page 2-13

Page 2-4 Page 2-8. Page Page 2-13 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings in AC3 440V duty: 6 to 630A IEC Power ratings in AC3 400V duty:. to 335kW UL/CSA ratings: 3 to 500HP

More information

2.3 LA1-DN10, DN01 LA6-DK LA8-DN LA1-DN LC1-LP1 LA8-DN LA1-DN, DC LA2-DT, DS LA3-DR LA1-DX, DY, DZ

2.3 LA1-DN10, DN01 LA6-DK LA8-DN LA1-DN LC1-LP1 LA8-DN LA1-DN, DC LA2-DT, DS LA3-DR LA1-DX, DY, DZ 110-17V AC-DC 50/60Hz E1 E LA1-DN10, DN01 0 LA6-DK LA6 DK10 LA8-DN LA1-DN.3 LA8-DN LC1-LP1 LA1-DN, DC LA-DT, DS LA3-DR LA1-DX, DY, DZ See right-hand page for mounting possibilities according to the contactor

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

For Info: Phone: Fax:

For Info:   Phone: Fax: Page -2 TWO POLES IEC rated current Ith: 20A (AC1) IEC operational power: 1.3kW (AC3 230V) Ideal for domestic applications. Page -2 THREE AND FOUR POLES IEC rated current Ith: 25A, 40A and 63A (AC1) IEC

More information

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h No Filter 81.6 % Auto 9.1 m3/h 250.0 m3/h Auto 99.7 m3/h 100.0 m3/h Auto 91.3 m3/h 92.0 m3/h Auto 40.0 m3/h 7. MW Auto 50.7 m3/h 50.0 m3/h 7.2 % Auto.6 % 45.0 % ABB NF Contactor Relays Overview...3 Ordering

More information

Motor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88.

Motor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88. Motor Starters Star-Delta Starters Open Type 86 Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88 Accessories 89 Reversing Contactors 90 Pole Changing Starters 92 Technical Data 94 Wiring

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

Modular contactor for installation into distribution boards

Modular contactor for installation into distribution boards Modular contactor for installation into distribution boards Description Modular contactors are used for installation in consumer units in dwellings, business premises, hotels, hospitals, shopping centres,

More information

Motor Protection Circuit Breaker

Motor Protection Circuit Breaker Motor Protection Circuit Breaker Catalogue 2011 CONTENT Introduction...4 Features...4 Parts Identification...5 Technical information (MPCB)...5 Technical information (Aux. contact, Fault signalling contact)...6

More information

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors... Three-pole versions up to 630A in IEC AC3 duty Four-pole versions up to 1600A in IEC AC1 duty Versions for power factor correction up to 100kvar at 400VAC Four-pole versions with NO+NC or 4NC main poles

More information

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated 11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information