TeSys contactors. Characteristics. Environment Rated insulation voltage 5/50. Contactor type LC1 D09 D18 DT20 and DT25. DT60A and DT80A.

Size: px
Start display at page:

Download "TeSys contactors. Characteristics. Environment Rated insulation voltage 5/50. Contactor type LC1 D09 D18 DT20 and DT25. DT60A and DT80A."

Transcription

1 Characteristics Contactor type LC1 D09 D18 DT20 and DT2 Environment Rated insulation voltage V 600 D2 D38 DT32 and DT40 D40A D6A DT60A and DT80A V D80 D9 D11 and D10 Rated impulse withstand voltage Conforming to standards kv 6 8 Degree of protection (2) and IEC 6029 (1) Protective treatment Ambient air temperature around the device C C C Maximum operating altitude m Operating positions (3) a/c a c Forc Flame resistance C 80 Shock resistance (4) Vibration resistance (4) (2) Protection provided for the cabling c.s.a.'s indicated on the next page and for connection by cable. (3) When mounting on a vertical rail, use a stop. (4) Without modifying the contact states, in the most unfavourable direction (coil energised at Ue). /0

2 Characteristics (continued) Contactor type LC1 D09 and D12 DT20 and DT2 D18 Power circuit connections Screw clamp terminal connections D2 D32 D38 D18 and D2 DT32 and DT40 Tightening Connector Flexible cable without cable end Flexible cable with cable end Solid cable without cable end D40A to D6A DT60A and DT80A (1) D80 and D9 Connector D11 and D10 Connector mm mm mm mm mm mm Screwdriver Hexagonal key Tightening torque N.m : y Spring terminal connections (2) Flexible cable without cable end mm 2 2. mm 2 2. Connection by bars or lugs Bar c.s.a. Lug external Ø mm Ø of screw mm Screwdriver Key for hexagonal headed screw Tightening torque N.m Control circuit connections Connection by cable (tightening via screw clamps) Flexible cable without cable end Flexible cable with cable end Solid cable without cable end mm mm mm mm mm mm Screwdriver Tightening torque N.m Spring terminal connections (2) Flexible cable without cable end Connection by bars or lugs mm mm Lug external Ø mm Ø of screw mm Screwdriver Tightening torque N.m (1) BTR screws: hexagon socket head. In accordance with local electrical wiring regulations, a size 4 insulated Allen key must be used (reference LAD ALLEN4, see page /8). (2) If cable ends are used, choose the next size down (example: for 2. mm 2, use 1. mm 2 ) and square crimp the cable ends using a special tool. /1

3 Characteristics (continued) Contactor type LC1 D09 Pole characteristics Rated operational current y DT20 D098 D12 DT2 D128 D18 DT32 D188 y A y A 2 (1) 20 2 (1) 2 (1) 40 (1) 40 Rated operational voltage V Frequency limits Hz Conventional thermal current y A 2 (1) 20 2 (1) 2 (1) 40 (1) 40 Rated making capacity A Rated breaking capacity A Permissible short time rating y Fuse protection y For 1 s A For 10 s A A A 40 0 A A D2 DT40 D28 A Average impedance per pole m Power dissipation per pole W AC-1 W Control circuit characteristics, a.c. supply Rated control circuit voltage V Control voltage limits Average consumption a VA Cos 0.7 VA 70 VA Cos VA 7 a VA Cos 0.7 VA 70 VA Cos VA 7. Heat dissipation W Operating time (2) Mechanical durability ms ms Maximum operating rate y (1) Versions with spring terminal connections: 16 A for LC1 D093 and LC1 D123 (20 A possible with 2 x 2. mm 2 in parallel), 2 A for LC1 D183 to LC1 D323 (32 A possible for LC1 D183 connected with 2 x 4 mm 2 cables in parallel; 40 A possible for LC1 D23 and LC1 D323 connected with 2 x 4 mm 2 in parallel). (2) The closing time "C" is measured from the moment the coil supply is switched on to closure of the main poles. The opening time "O" is measured from the moment the coil supply is switched off to the moment the main poles separate. /2

4 D32 D38 D40A DT60A D0A D6A DT80A D80 D9 D11 D (1)

5 Characteristics (continued) Contactor type d.c. control circuit characteristics Rated control circuit voltage LC1 D09 D38 LC1 DT20 DT40 LC1 D40A D6A LC1 DT60A and DT80A LC1 or LP1 D80 LC1 D9 LC1 D11 and LC1 D10 c V Rated insulation voltage V 690 V 600 Control voltage limits Standard Average consumption Operating time (1) average at Uc Uc Uc Uc Uc Uc Uc Uc c W W ms ms 40 7 Note: The arcing time depends on the circuit switched by the poles. For all normal 3-phase applications, the arcing time is less than 10 ms. The load is isolated from the supply after a time equal to the sum of the opening time and the arcing time. Time constant ms Mechanical durability at Uc Maximum operating rate y 1200 Low consumption control circuit characteristics Rated insulation voltage V 690 V 600 Maximum voltage c V 20 Average consumption W 2.4 W 2.4 Operating time (1) Voltage limits ( y 60 C) of the control circuit ms ms 0.8 to 1.2 Uc Time constant ms 40 Mechanical durability Maximum operating rate y (1) The operating times depend on the type of contactor electromagnet and its control mode. The closing time "C" is measured from the moment the coil supply is switched on to initial contact of the main poles. The opening time "O" is measured from the moment the coil supply is switched off to the moment the main poles separate /4

6 Characteristics (continued) Characteristics of auxiliary contacts incorporated in the contactor Mechanically linked contacts Mirror contact Rated operational voltage Rated insulation voltage Conventional thermal current V 690 V 690 V 600 y A 10 Frequency of the operational current Hz Minimum switching V 17 capacity = 10 8 ma Short-circuit protection Rated making capacity A ac: 20 Short-time rating 1 s A 100 A 120 A 140 Insulation resistance M > 10 Non-overlap time Operational power of contacts ms a.c. supply, categories AC-14 and AC-1 d.c. supply, category DC-13 V V VA W VA W 48 VA W AC ,8 1 0,6 0,4 0,3 0,2 DC ,8 1 0,6 0,4 0,3 0,2 440 V 24 V 48 V 12 V 20 V 0,1 0,1 0,2 0,3 0, 0,8 0,4 0, ,1 0,1 0,2 0,3 0, 0,8 0,4 0, /

7 Characteristics Contact block type LAD N or LAD C LAD T and LAD S LAD R LAD 8 Environment Conforming to standards Protective treatment Degree of protection Ambient air temperature around the device C C C Maximum operating altitude m Connection by cable Spring terminal connections mm 2 mm 2 Instantaneous and time delay contact characteristics Number of contacts Rated operational voltage Rated insulation voltage V 690 V 690 V 600 Conventional thermal current y A 10 Frequency of the operational current Hz Minimum switching capacity V 17 Short-circuit protection Rated making capacity IEC ma A 10 A a c: 20 Short-time rating 1 s A 100 A 120 A 140 Insulation resistance M > 10 Non-overlap time Overlap time Time delay LAD C22 ms ms 1. C Mechanical durability Operational power of contacts /79 and /80 /6 /92 and /96 and /97

8 Characteristics (continued) Contact block type LA1 DX LA1 DZ LA1 DY Environment Conforming to standards Protected Non protected Protective treatment Degree of protection Ambient air temperature C Cabling mm 2 Number of contacts Contact characteristics Rated operational voltage Rated insulation voltage V V V 600 Conventional thermal current Maximum operational current y A 10 ma Frequency of the operational current Hz Minimum switching capacity V ma Short-circuit protection Rated making capacity IEC A 10 A a c: 20 Short-time rating 1 s A 100 A 120 A 140 Insulation resistance M > 10 > 10 > 10 > 10 Mechanical durability Materials and technology /79 and /80 /92 and /96 and /97 /7

9 Characteristics (continued) Rated operational power of contacts (conforming to IEC ) a.c. supply, categories AC-14 and AC-1 V VA VA VA ,8 0,7 0,6 0, 0,4 0,3 0,2 0,1 0,1 0,2 0,3 0,4 0,6 0, , 0,7 0, d.c. supply, category DC-13 V W W W V 12 V 48 V 24 V 1 0,8 0,7 0,6 0, 0,4 0,3 440 V 0,2 0,1 0,1 0,2 0,3 0,4 0,6 0, , 0,7 0, /79 /8 /92 and /96 and /97

10 Characteristics Environment Conforming to standards IEC Protective treatment Degree of protection Ambient air temperature around the device C C C Suppressor modules Module type LA4 DA, LAD 4RC, LAD 4RC3 LA4 DB, LAD 4T, LAD 4T3 Type of protection LA4 DC, LAD 4D3 LA4 DE, LAD 4V, LAD 4V3 Rated control circuit voltage V a a orc c a orc24 20 Maximum peak voltage 2 Uc Uc 2 Uc Natural RC frequency Hz 400 Hz 200 Hz 100 Hz 10 Mechanical latch blocks (1) Mechanical latch block type LAD 6K10 LA6 DK20 For use on contactor LC1 D09 D6A DT20 DT80A LC1 D80 D10 LP1 D80 and LC1 D11 Rated insulation voltage V Rated control circuit voltage a c V Power required a VA 2 2 c W Maximum operating rate On-load factor Mechanical durability at Uc (1) Unlatching can be manually operated or electrically controlled (pulsed). The LA6 DK or LAD 6K latch coil and the LC1 D operating coil must not be energised simultaneously. The duration of the LA6 DK or LAD 6K and LC1 D control signals must be u 100 ms. /79 and /80 /92 and /96 and /97 /9

11 Characteristics Module type LA4 DT Environment Conforming to standards IEC 602- Protective treatment Degree of protection Ambient air temperature around the device C C C Rated insulation voltage V 20 Cabling mm 2 Control circuit characteristics Built-in protection Rated control circuit voltage V a or c : Permissible variation Uc Type of control Timing characteristics Timing ranges s Repeat accuracy Reset time ms 10 ms 0 Immunity to microbreaks ms 10 ms 2 Minimum control pulse duration ms Time delay signalling Switching characteristics (solid state type) Maximum power dissipated W 2 Leakage current ma < Residual voltage V Overvoltage protection Electrical durability Function diagram Electronic on-delay timer LA4 DT t / /60 /92 and /96 and /97

12 Characteristics Environment Conforming to standards IEC 602- Protective treatment Degree of protection Ambient air temperature around the device Other characteristics Module type Conventional thermal current C C C y A 8 Rated insulation voltage V 20 Rated operational voltage V 20 LA4 DFB LA4 DWB Indication of input state Input signals V c 24 c 24 V ma 2 U V < 2.4 < 2.4 I ma < 2 < 2 U V 17 Built-in protection Electrical durability Maximum immunity to microbreaks ms 4 1 Power dissipated W Direct mounting on contactor Mounting with cabling adapter LAD 4BB Mounting with cabling adapter LAD 4BB3 Total operating time at Uc a LC1 D80 D10 a LC1 D80 D11 a a LC1 D09 D38, LC1 DT20 DT40 a LC1 D09 D38, LC1 DT20 DT40 a LC1 D40A D6A LC1 D40A D6A a LC1 D40A D6A LC1 D40A D6A LC1 D09 D38, LC1 DT20 DT40 LC1 D40A D6A LA4 DFB ms LC1 D80 and D9 ms Cabling mm 2 / /92 and /96 and /97 /61

13 References LC1 D09pp LC1 D2pp 3-pole contactors Standard power ratings of 3-phase motors 0-60 Hz in category AC-3 ( y 60 C) 220 V 380 V 41 V 440 V 00 V 660 V 1000 V 230 V 400 V 690 V Rated operational current in AC V up to Instantaneous auxiliary contacts Basic reference, to be completed by adding the control voltage code (2) Fixing (1) (3) kw kw kw kw kw kw kw A kg Connection by screw clamp terminals LC1 D09pp LC1 D12pp LC1 D18pp LC1 D2pp LC1 D32pp LC1 D38pp Power connections by Ever BTR screw connectors (4) and control by spring terminals LC1 D40App () LC1 D0App () LC1 D6App () Connection by screw clamp terminals or connectors LC1 D80pp LC1 D9pp LC1 D11pp LC1 D10pp 2.00 Connection by lugs or bars 6 LC1 D09pp LC1 D096pp LC1 D6App LC1 D9pp LC1 D11pp Separate components Auxiliary contact blocks and add-on modules (1) LC1 D09 to D6A: clip-on mounting on 3 mm LC1 D80 to D9 a: clip-on mounting on 3 mm rail AM1 DP or 7 mm LC1 D80 to D9 c : clip-on mounting on 7 mm LC1 D11 and D10: clip-on mounting on 2 x 3 mm a.c. supply Volts LC1 D09 D10 E7 F7 FE7 P7 U7 Q7 R7 S7 LC1 D80 D11 E F FE P U Q R S E6 F6 U6 Q6 R6 d.c. supply Volts LC1 D09 D6A U Uc LC1 D80 D9 U Uc U Uc LC1 D11 and D10 U Uc Low consumption Volts c LC1 D09...D38 U Uc For other voltages between and 690 V, see pages /86 to /91. (3) The weights indicated are for contactors with a.c. control circuit. For d.c. or low consumption control circuit, add kg from LC1 D09 to D38, 0.07 kg from LC1 D40A to D6A and 1 kg for LC1 D80 and D9. (4) BTR screws: hexagon socket head. In accordance with local electrical wiring regulations, a size 4 insulated Allen key must be used (reference LAD ALLEN4, see page /8). () For low consumption kit LA4 DBL (see page /83). /62

14 References pole contactors Standard power ratings of 3-phase motors 0-60 Hz in category AC-3 ( y 60 C) 220 V 380 V 41 V 440 V 00 V 660 V 1000 V 230 V 400 V 690 V Rated operational current in AC V up to Instantaneous auxiliary contacts Basic reference, to be completed by adding the control voltage code (2) Fixing (1) (3) LC1 D123pp kw kw kw kw kw kw kw A kg Power and control connections by spring terminals LC1 D093pp LC1 D123pp LC1 D183pp LC1 D23pp (4) 1 1 LC1 D323pp Power connections by Ever BTR screw connectors () and control by spring terminals LC1 D40A3pp (6) LC1 D0A3pp (6) LC1 D6A3pp (6) Connection by Faston connectors 39 LC1 D093pp LC1 D099pp. Separate components Auxiliary contact blocks and add-on modules LC1 D6A3pp (1) LC1 D09 to D32: clip-on mounting on 3 mm a.c. supply Volts LC1 D09 D6A E7 F7 FE7 P7 U7 Q7 R7 d.c. supply Volts LC1 D09 D6A U Uc Low consumption Volts c LC1 D09...D32 U Uc For other voltages between and 690 V, see pages /86 to /91. (3) The weights indicated are for contactors with a.c. control circuit. For d.c. or low consumption control circuit, add kg from LC1 D09 to D32 and 0.07 kg from LC1 D40A to D6A. (4) Must be wired with 2 x 4 mm 2 cables in parallel on the upstream side. On the downstream side, outgoing terminal block LAD 331 kw/400 V motors). () BTR screws: hexagon socket head. In accordance with local electrical wiring regulations, a size 4 insulated Allen key must be used (reference LAD ALLEN4, see page /8). (6) For low consumption kit LA4 DBL (see page /83).

15 References 3-pole contactors Non inductive loads maximum current ( y 60 C) utilisation category AC-1 Number of poles Instantaneous auxiliary contacts Basic reference, to be completed by adding the control voltage code (1) Fixing (2) (3) LC1 D09pp A kg Connection by screw clamp terminals LC1 D09pp or LC1 D12pp LC1 D18pp LC1 D2pp LC1 D32pp or LC1 D38pp Connection by Ever, BTR screw connectors (4) LC1 D40App (7) LC1 D0App (7) 0.8 Connection by screw clamp terminals or connectors or LC1 D6App () (7) LC1 D80pp 1.90 or LC1 D9pp () LC1 D11pp pole contactors for connection by lugs 6 LC1 D09pp LC1 D096pp. or LC1 D10pp (6) 2.00 LC1 D6App a.c. supply Volts LC1 D09...D10 E7 F7 FE7 P7 U7 Q7 R7 LC1 D80...D10 E F FE P U Q R S E6 F6 U6 Q6 R6 d.c. supply Volts LC1 D09...D6A U Uc LC1 or LP1 D80 and D9 U Uc U Uc LC1 D11 and D10 U Uc Low consumption Volts c LC1 D09...D38 U Uc For other voltages between and 690 V, see pages /86 to /91. (2) LC1 D09 to D6A: clip-on mounting on 3 mm rail AM1 DP LC1 D80 and D9a: clip-on mounting on 3 mm rail AM1 DP or 7 mm rail AM1 DL LC1 or LP1 D80 to D9c: clip-on mounting on 7 mm rail AM1 DL LC1 D11 and D10: clip-on mounting on 2 x 3 mm rails AM1 DP (3) The weights indicated are for contactors with a.c. control circuit. For d.c. or low consumption control circuit, add kg from LC1 D09 to D38, 0.07 kg from LC1 D40A to D6A and 1 kg for LC1 D80 and D9. (4) BTR screws: hexagon socket head. In accordance with local electrical wiring regulations, a size 4 insulated Allen key must be used (reference LAD ALLEN4, see page /8). () Selection according to the number of operating cycles, see AC-1 curve, page /198. (6) 32 A with 2 x 4 mm 2 cables connected in parallel. (7) For low consumption kit LA4 DBL (see page /83). /64

16 References (continued) 3-pole contactors for connection by Faston connectors 9 LC1 D09pp LC1 D099pp. 3-pole contactors Non inductive loads maximum current ( y 60 C) utilisation category AC-1 Number of poles Instantaneous auxiliary contacts Basic reference, to be completed by adding the control voltage code (1) Fixing (2) (3) LC1 D123pp A kg Connection by spring terminals LC1 D093pp (4) or LC1 D123pp (4) LC1 D183pp () or LC1 D23pp (6) or LC1 D323pp (6) Power connections by EverLink BTR screw connectors (7) and control by spring terminals LC1 D40A3pp (9) LC1 D0A3pp (8) (9) 0.8 or LC1 D6A3pp (8) (9) Separate components Auxiliary contact blocks and add-on modules LC1 D6A3pp a.c. supply Volts LC1 D09...D6A E7 F7 FE7 P7 U7 Q7 R7 S7 d.c. supply Volts LC1 D09...D6A U Uc Low consumption Volts c LC1 D09...D38 U Uc For other voltages between and 690 V, see pages /86 to /91. (2) LC1 D09 to D6A: clip-on mounting on 3 mm rail AM1 DP (3) The weights indicated are for contactors with a.c. control circuit. For d.c. or low consumption control circuit, add kg from LC1 D09 to D38 and 0.07 kg from LC1 D40A to D6A. (4) 20 A with 2 x 2. mm 2 cables connected in parallel. () 32 A with 2 x 4 mm 2 cables connected in parallel. (6) 40 A with 2 x 4 mm 2 cables connected in parallel. (7) BTR screws: hexagon socket head. In accordance with local electrical wiring regulations, a size 4 insulated Allen key must be used (reference LAD ALLEN4, see page /8). (8) Selection according to the number of operating cycles, see AC-1 curve, page /198. (9) For low consumption kit LA4 DBL (see page /83). /6

17 References (continued) pole contactors for connection by screw clamp terminals or connectors Non inductive loads maximum current ( y 60 C) utilisation category AC-1 Number of poles Instantaneous auxiliary contacts Basic reference, to be completed by adding the control voltage code (1) Fixing (2) (3) LC1 DT20pp LC1 DT80App A Connection by screw clamp terminals LC1 DT20pp LC1 D098pp LC1 DT2pp LC1 D128pp LC1 DT32pp LC1 D188pp LC1 DT40pp LC1 D28pp 0.42 Connection by Ever, BTR screw connectors LC1 DT60App LC1 DT80App 1.10 Connection by screw clamp terminals or connectors LC1 D40008pp or LP1 D40008pp LC1 D6008pp 1.40 or LP1 D6008pp LC1 D80004pp or LP1 D80004pp LC1 D80008pp or LP1 D80008pp LC1 D11004pp kg LC1 D6008pp 4-pole contactors for connection by lugs or bars 6 LC1 DT20pp LC1 DT206pp. a.c. supply Volts LC1 D09...D10 and LC1 DT20...DT80A E7 F7 FE7 P7 U7 Q7 R7 LC1 D80...D11 E F FE P U Q R S E6 F6 U6 Q6 R6 d.c. supply Volts LC1 D09...D6A and LC1 DT20...DT80A U Uc LC1 or LP1 D80 U Uc U Uc LC1 D11 U Uc Low consumption Volts c LC1 D09...D38 and LC1 DT20...DT40 U Uc For other voltages between and 690 V, see pages /86 to /91. (2) LC1 D09 to D38 and LC1 DT20 to DT80A: clip-on mounting on 3 mm rail AM1 DP LC1 D80a: clip-on mounting on 3 mm rail AM1 DP or 7 mm rail AM1 DL LC1 or LP1 D80c: clip-on mounting on 7 mm rail AM1 DL LC1 D11 and D10: clip-on mounting on 2 x 3 mm rails AM1 DP (3) The weights indicated are for contactors with a.c. control circuit. For d.c. or low consumption control circuit, add kg from LC1 D09 to D38, 0.07 kg from LC1 DT60A and D80A and 1 kg for LC1 D80. /66

18 References (continued) 4-pole contactors Non inductive loads maximum current ( y 60 C) utilisation category AC-1 Number of poles Instantaneous auxiliary contacts Basic reference, to be completed by adding the voltage code (1) Fixing (2) (3) A Connection by spring terminals LC1 DT203pp LC1 D0983pp LC1 DT23pp LC1 D1283pp LC1 DT323pp LC1 D1883pp LC1 DT403pp LC1 D283pp 0.42 Connection by by Ever, BTR screw connectors and control circuit by spring terminals LC1 DT60A3pp LC1 DT80A3pp 1.10 Separate components Auxiliary contact blocks and add-on modules kg a.c. supply Volts LC1 D09...D2 and LC1 DT20...DT80A E7 F7 FE7 P7 U7 Q7 R7 d.c. supply Volts LC1 D09...D2 and LC1 DT20...DT80A U Uc Low consumption Volts c LC1 D09...D2 and LC1 DT20...DT40 U Uc For other voltages between and 690 V, see pages/86 to /91. (2) LC1 D09 to D38 and LC1 DT20 to DT80A: clip-on mounting on 3 mm rail AM1DP (3) The weights indicated are for contactors with a.c. control circuit. For d.c. or low consumption control circuit, add kg from LC1 D09 to D38, 0.07 kg for LC1 DT60A and DT80A. /67

19 Presentation M Starters for the North American market (1) (2) (3) standards. Combination Starters Type E self-protected combination starter Type F, Combination motor starter (1) UL: Underwriters Laboratories, CSA: Canadian Standards Association, ACNE: Association NEC: National Electric Code, CEC: Canadian Electrical Code, MEC: Mexican Electrical Code. (2) Canena: Council for Harmonization of Electrotechnical Standardization of North America. (3) IEC: International Electrotechnical Commission. /68

20 Presentation (continued) Control panels short-circuit current rating type E or type F /69

21 Presentation (continued) Group protection motor group installations Case n 1 Case n 2 tap conductor protection type F type F. /70

22 Reference LC1 D09pp LC1 D2pp Contactors Standard power ratings of motors 0/60 Hz Size Associated Continuous Single-phase 3-phase cable current 1 Ø 3 Ø type 7 C-Cu 11 V 230 V 240 V 200 V 208 V 230 V 240 V 460 V 480 V 7 V 600 V HP HP HP HP HP HP A Connection by screw clamp terminals LC1 D09pp LC1 D12pp LC1 D18pp LC1 D2pp LC1 D32pp Type of contactor required Basic reference, to be completed (1) Fixing, connection (2) Power connections by EverLink BTR screw connectors (4) and control by spring terminals LC1 D40App LC1 D0App LC1 D6App Connection by screw clamp terminals or connectors LC1 D80pp LC1 D9pp LC1 D11pp LC1 D10pp Applications with High-Fault Short-Circuit ratings For contactors LC1 D40A to LC1 D6A LAD UL1.. Description Language Sold in lots of Reference Warning sticker 10 LAD UL1 Application example For a 1 HP-230 V motor LC1 D0A LC1 D6App LC1 D9pp a.c. supply Volts LC1 D09 D10 E7 F7 FE7 P7 U7 Q7 R7 S7 LC1 D80 D11 E F FE P U Q R S E6 F6 U6 Q6 R6 d.c. supply Volts LC1 D09 D6A U Uc LC1 D80 and D9 U Uc U Uc LC1 D11 and D10 U Uc Low consumption Volts c LC1 D09 D38 U Uc (2) LC1 D09 to D6A: clip-on mounting on 3 mm 6 rail AM1 DP LC1 D80 and LC1 D9: clip-on mounting on 3 mm 6 rail AM1 DP or 7 mm 6 rail AM1 DL LC1 D11 and D10: clip-on mounting on 2 x 3 mm 6 rails AM1 DP /71

23 References pole reversing contactors for connection by screw clamp terminals Pre-wired power connections. LC2 D12pp Standard power ratings of 3-phase motors 0-60 Hz in category AC-3 ( y 60 C) 220 V 380 V 41 V 440 V 00 V 660 V 230 V 400 V 690 V 1000 V Rated operational current in AC V up to Instantaneous auxiliary contacts per contactor Contactors supplied with coil Basic reference, to be completed by adding the control voltage code (2) Fixing (1) (3) LC2 D6App kw kw kw kw kw kw kw A kg With mechanical interlock, without electrical interlocking, for connection by screw clamp terminals or connectors LC2 D09pp (4) LC2 D12pp (4) LC2 D18pp (4) LC2 D2pp (4) LC2 D32pp (4) LC2 D38pp (4) LC2 D40App () LC2 D0App () LC2 D6App () LC2 D80pp LC2 D9pp 2617 With mechanical interlock and electrical interlocking, for connection by screw clamp terminals or connectors LC2 D11pp LC2 D10pp LC2 D11pp Connection by lugs or bars 6 LC2 D09pp LC2 D096pp. LC1 DppA6 LAD 4CM Component parts Auxiliary contact blocks and add-on modules (1) LC2 D09 to D6A: clip-on mounting on 3 mm rail AM1 DP LC2 D80 and D9: clip-on mounting on 3 mm rail AM1 DP or 7 mm rail AM1 DL LC2 D11 and D10: clip-on mounting on 3 mm rail AM1 DP a.c. supply Volts LC2 D09 D10 E7 F7 FE7 P7 U7 Q7 R7 S7 LC2 D80 D11 E F FE P U Q R S E6 F6 U6 Q6 R6 d.c.supply Volts LC2 D09 D6A U Uc Low consumption Volts c LC2 D09...D38 U Uc For other voltages between and 690 V, see pages /86 to /91. (3) The weights indicated are for contactors with a.c. control circuit. For d.c. or low consumption control circuit, add kg for LC2 D09 to D38, 0.10 kg for LC1 D40A to D6A. V to the references selected above. Example: LC2 D09P7 becomes LC2 D09P7V. () For low consumption kit LA4 DBL (see page /83). Note: when assembling a reversing contactor, it is good practice to incorporate a 0 ms time delay. /72

24 References pole reversing contactors, for connection by spring terminals Pre-wired power connections. LC2 D123pp Standard power ratings of 3-phase motors 0-60 Hz in category AC-3 ( y 60 C) 220 V 380 V 41 V 440 V 00 V 660 V 230 V 400 V 690 V Rated operational current in AC V up to Instantaneous auxiliary contacts per contactor Contactors supplied with coil Basic reference, to be completed by adding the voltage code (2) Fixing (1) (3) kw kw kw kw kw kw A kg For connection by spring terminals LC2 D093pp LC2 D123pp LC2 D183pp LC2 D23pp (4) 1 1 LC2 D323pp Power connection by Ever, BTR screw connectors () and control by spring terminals LC2 D40A3pp (6) LC2 D0A3pp (6) LC2 D6A3pp (6) For connection by Faston connectors All power connections are to be made by the customer LC2 D093pp LC2 D099pp. Component parts Auxiliary contact blocks and add-on modules (1) LC2 D09 to D32: clip-on mounting on 3 mm rail AM1 DP a.c. supply Volts LC2 D09 D6A E7 F7 FE7 P7 U7 Q7 R7 S7 d.c. supply Volts LC2 D09 D6A U Uc Low consumption Volts c LC2 D09...D38 U Uc For other voltages between and 690 V, see pages /86 to /91. (3) The weights indicated are for reversing contactors with a.c. control circuit. For d.c. or low consumption control circuit, add kg for LC2 D09 to D38, 0.10 kg for LC1 D40A to D6A. (4) Must be wired with 2 x 4 mm 2 cables in parallel on the upstream side. On the downstream side, outgoing terminal block LAD 331 kw/400 V motors). () BTR screws: hexagon socket head. In accordance with local electrical wiring regulations, a size 4 insulated Allen key must be used (reference LAD ALLEN4, see page /8). (6) For low consumption kit LA4 DBL (see page /83).

25 References 20 to 200 A LC2 DT20pp Pre-assembled. Pre-wired power connections. For connection by screw clamp terminals or connectors p Utilisation category AC-1 Non-inductive loads Maximum rated operational current ( y 60 C) A Instantaneous auxiliary contacts per contactor Contactors supplied with coil Basic reference, to be completed by adding the voltage code (1) Fixing (2) LC2 DT20pp kg LC2 DT2pp LC2 DT32pp LC2 DT40pp LC2 D80004pp 200 LC2 D11004pp For connection by lugs or bars LC2 DT206pp LC2 DT26pp LC2 DT326pp LC2 DT406pp 0.80 For customer assembly. For connection by screw clamp terminals or connectors LC1 DT60App (3) LC1 DT80App (3) For connection by lugs or bars LC1 DT60A6pp (3) LC1 DT80A6pp (3) Accessories Auxiliary contact blocks and add-on modules (1) See note (1) on next page. (2) LC2 DT20 to LC2 DT80: clip-on mounting on 3 mm rail AM1 DP LC2 D80: clip-on mounting on 3 mm rail AM1 DP or 7 mm rail AM1 DL LC2 D11: clip-on mounting on 2 x 3 mm rails AM1 DP (3) For these operational currents, order 2 identical contactors and a mechanical interlock LAD 4CM (see page /76). Note: when assembling changeover contactor pairs, it is good practice to incorporate a 0 ms time delay. /74

26 References Pre-assembled. Pre-wired power connections. For connection by spring terminals. Utilisation category AC-1 Non-inductive loads Maximum rated operational current ( y 60 C) Instantaneous auxiliary contacts per contactor Contactors supplied with coil Basic reference, to be completed by adding the control voltage code (1) Fixing (2) A LC2 DT203pp For customer assembly. Power connection by Ever, BTR screw connectors (3) and control by spring terminals LC1 DT60A3pp (4) LC1 DT80A3pp (4) Separate components Auxiliary contact blocks and add-on modules kg a.c. supply Volts LC2 DT20 DT40, LC1 DT60 DT80 E7 F7 FE7 P7 U7 Q7 R7 LC2 D80004 D11004 E F FE P U Q R S E6 F6 U6 Q6 R6 d.c. supply Volts LC2 DT20 DT40, LC1 DT60 DT80 U Uc Low consumption Volts c LC2 DT20...DT40 U Uc For other voltages between and 690 V, see pages /86 to /91. (2) Clip-on mounting on 3 mm rail AM1 DP (3) BTR screws: hexagon socket head. In accordance with local electrical wiring regulations, a size 4 insulated Allen key must be used (reference LAD ALLEN4, see page /8). (4) For these operational currents, order 2 identical contactors and a mechanical interlock LAD 4CM (see page /76). /7

27 References LAD 9R1 For 3-pole reversing contactors for motor control Description For contactors (1) Kits for assembly of reversing contactors Kit comprising: b LAD 9V2 LAD 9V1. b LAD 9V and LAD 9V6 Kit comprising: b LAD 9V2 b LAD 9V and LAD 9V6 Kit comprising: b LAD 4CM b LA9 D6A69. Reference kg LAD 9R1V 0.04 LAD 9R LAD 9R LAD 9R3 Mechanical interlocks Mechanical interlock with integral electrical interlocking a LA9 D c LA9 D LA9 D LA9 D8069 Mechanical interlock without integral electrical interlocking Sets of power connections Comprising: b b For low-speed/high-speed starter Description Connection kit LAD 9V LAD 4CM a LA9 D c LA9 D LAD 9V LAD 9V6 LAD 9V12 LAD 9V13 (2) LA9 D6A69 a LA9 D c LA9 D LA9 D For contactors with connection type Reference kg LAD 9PVGV LAD 3PVGV LAD 3PVGV10 For star-delta starter Description For contactors Reference kg Mounting kit b LAD S2, b b LAD LAD LAD 9SD3 LA9 D Equipment mounting plates LA9 D LA9 D LA9 D80973 (1) To order the 2 contactors: see pages /6 and /72. (2) To assemble a reversing contactor with spring terminal connections, the following components must be ordered: - 1 mechanical interlock LAD 9V2, - 1 upstream power connection kit and 1 downstream power connection kit.. Upstream power connection kit LAD 9V10 LAD 34. (If module LAD 34 is not used, replace LAD 9V10 with LAD 9V12). Downstream power connection kit LAD 9V11 LAD 331. (If LAD 331 is not used, replace LAD 9V11 with LAD 9V13). /76

28 References For 4-pole changeover contactor pairs (3-phase distribution + neutral) Description For contactors (1) Kits for assembly of changeover contactor pairs Kit comprising: b LAD 9V2 LAD 9V1 b LAD 9V7. Reference kg LAD T9R1V 0.04 Kit comprising: b LAD 9V2 b LAD 9V7. Mechanical interlocks With integral electrical interlocking LAD T9R LA9 D LA9 D LA9 D LA9 D0978 Without integral electrical interlocking LAD 9V2 (2) LAD 9V2 (2) LAD 4CM LA9 D LA9 D LA9 D670 Sets of power connections Comprising a set of parallel bars LA9 D6A70 r 0.10 LA9 D LA9 D LA9 D LAD 9V LA9 D8070 (2) LA9 D8070 (2) For 3-pole changeover contactor pairs LA9 D8070 Description For contactors (1) Mechanical interlocks Without integral electrical interlocking Reference kg LAD 9R3S 0.10 With integral electrical interlocking LA9 D Sets of power connections Comprising a set of parallel bars, LA9 D (1) To order the 2 contactors: see pages /6 and /72. (2) Order 2 contact blocks LAD Np1 to build the electrical interlock, see page /79. r st /77

29 or /78

30 References Instantaneous auxiliary contact blocks for connection by screw clamp terminals For use in normal operating environments Clip-on mounting (1) Number of contacts per block Composition Reference kg Front 1 1 LAD N LAD N LAD N11 2 LAD N20 2 LAD N LAD N LAD N LAD N LAD N LAD N LAD C Side LAD 8N11 2 LAD 8N20 2 LAD 8N02 For terminal referencing conforming to EN 0012 Front LAD N11G 4P contactors 20 to 80 A LAD N22G 0.00 Front on 4P contactors LAD N11P 12 to 200 A LAD N22P 0.00 With dust and damp protected contacts, for use in particularly harsh industrial environments Front 2 2 LA1 DX LA1 DX LA1 DX LA1 DY20 (2) LA1 DZ LA1 DZ Instantaneous auxiliary contact blocks for connection by lugs 6 LAD N11 LAD N116. Instantaneous auxiliary contact blocks for connection by spring terminals 3 LAD N11 LAD N113. Instantaneous auxiliary contact blocks for connection by Faston connectors 9 LAD N11 LAD N119. Contactors Instantaneous auxiliary contacts Time delay Type Number of poles and size Side mounted Front mounted Front 1 contact 2 contacts 4 contacts mounted a and 1 or 1 or 1 and 1 or 1 or 1 or 2 and 1 or 1 or 1 and 2 and 1 or 1 or 1 and 1 or 1 or 1 4P and 1 or 1 or 1 and 1 or 1 or 1 or 1 or 1 or 1 or 1 and 1 or 1 or 1 or 1 c 1 or 1 or 1 1 or 1 or 1 1 or 1 or 1 or 1 and 1 or 1 or 1 4P 1 or 1 or 1 1 or 1 or 1 2 and 1 or 1 or 1 and 1 or 1 or 1 (3) 1 4P 1 (3) LC: low consumption. /79

31 References Time delay auxiliary contact blocks for connection by screw clamp terminals LAD Tp Clip-on mounting Number of contacts Time delay Reference Type Setting range Front LAD T kg LAD T s LAD T LAD S LAD R LAD R s LAD R LAD Tp3 Time delay auxiliary contact blocks for connection by lugs 6 LAD T0 LAD T06. Time delay auxiliary contact blocks for connection by spring terminals 3 LAD T0 LAD T03 Time delay auxiliary contact blocks for connection by Faston connectors 9 LAD T0 LAD T09. Mechanical latch blocks (1) Clip-on mounting Front Unlatching control For use on contactor a orc a orc Basic reference, to be completed by adding the control voltage code (2) kg LAD 6K10p a orc a orc LAD 6K10p LAD 6K10p a c a a c LA6 DK20p (1) The mechanical latch block must not be powered up at the same time as the contactor. The duration of the control signal for the mechanical latch block and the contactor should be: u 100 ms for a contactor operating on an a.c. supply, u 20 ms for a contactor operating on a d.c. supply. Maximum impulse duration for the LAD 6K10p mechanical latch block: 10 seconds. Volts 0/60 Hz, c 24 32/36 42/48 60/ / /240 26/ /41 Code C E F U Q /80

32 References LAD 4pp LAD 4RC3p, LAD 4V3p, LAD 4D3U, LAD 4T3p LA4 Dpp LAD 4DDL or LAD 4TpDL RC circuits (Resistor-Capacitor) Mounting For use with contactor (1) Reference Clip-on side mounting (3) Clip-on front mounting (3) (4) Rating Type Va Vc kg LAD 4RCE LAD 4RCG LAD 4RCU LAD 4RC3E LAD 4RC3G LAD 4RC3U LAD 4RC3N LA4 DA2E LA4 DA2G LA4 DA2U LA4 DA2N Varistors (peak limiting) Clip-on side mounting (3) Clip-on front mounting (3) (4) LAD 4VE LAD 4VG LAD 4VU LAD 4V3E LAD 4V3G LAD 4V3U LA4 DE2E LA4 DE2G LA4 DE2U LA4 DE3E LA4 DE3G LA4 DE3U Flywheel diodes Clip-on side mounting () LAD 4DDL Clip-on front mounting () LAD 4D3U (4) LA4 DC3U Bidirectional peak limiting diodes Clip-on side mounting (3) () Clip-on front mounting (3) (4) (2) (2) 24 LAD 4TB LAD 4TBDL LAD 4TS LAD 4TSDL LAD 4TGDL LAD 4TUDL LAD 4TXDL LAD 4T3B LAD 4T3S LAD 4T3G LAD 4T3U LAD 4T3R LA4 DB2B LA4 DB2S LA4 DB3B LA4 DB3S bidirectional peak limiting diode suppressor as standard. This bidirectional peak limiting diode is removable and can therefore be replaced by the user. (See reference above). If a d.c. or low consumption contactor is used without suppression, the standard suppressor should be replaced with a blanking plug (reference LAD 9DL for LC1 D09 to D38 and LC1 DT20 to DT40; reference LAD 9DL3 for LC1 D40A to D6A and LC1 DT60A to DT80A). (3) Clipping-on makes the electrical connection. The overall size of the contactor remains unchanged. (4) Mounting at the top of the contactor on coil terminals A1 and A2. /81

33 /82

34 References Electronic serial timer modules (1) b b b On-delay type Operational voltage a Time delay Reference V V s LA4 DT0U LA4 DT2U s LA4 DT4U Interface modules b b Relay interface Operational voltage a V Supply voltage E1-E2 (c) Reference kg LA4 DFB 0.00 kg Relay interface with "AUTO-I" manual override switch (output forced ON ), solid state type Operational voltage a V V Supply voltage E1-E2 (c) Reference LA4 DWB 0.04 kg Low consumption kit For use on contactors Composition Reference kg (2) b b For adapting existing wiring to a new product LA4 DBL For use on contactors Reference kg LAD 4BB a LAD 4BBVE a LAD 4BBVG a LAD 4BBVU LAD 4BB (2) The kit is compatible with a coil voltage of a 24 V to a 20 V (B7 to U7) and c 24 V to c 20 V (BD to UD).

35 References (continued) LA9 D3260 Accessories for main pole and control connections Description For use with contactors LC1 Sold in Connectors for cable, size a c lots of Unit reference 2 1 LAD LA9 D kg Ever terminal block 1 LAD Connectors for cables 2 1 LA9 D LA9 D LA9 D110p Connectors for lug type terminals 1 LA9 D LA9 D1104 LAD 9670 Protective covers for connectors for lug type terminals 1 LAD LA9 D11703 (1) LAD LA9 D11704 LA9 D1160p IP 20 covers for lug type terminals pppp Links for parallel connection of 1 LAD LA9 D LA9 D LAD LAD 9P LA9 D LAD 9P3 (2) LAD 9P LA9 D1170p 1 LA9 D LA9 D LA9 D Staggered coil connection 10 LA9 D LA9 D80962 Control circuit take-off from main pole 10 LA9 D LA9 D LA9 D1167 Spreaders 3 GV7 AC (1) For 3-pole contactors: 1 set of 6 covers, for 4-pole contactors: 1 set of 8 covers. (2) Separate connecting bar for connecting 2 poles in parallel. /84

36 References (continued) GV2 G24 GV1 G09 GV3 S LA9 D941 LAD 9ETp LAD 7X3 Sets of contacts and arc chambers Description For contactor Reference kg Sets of contacts LA D LA D LA D11804 Arc chambers LA D110 LA D100 LA D Power connection accessories Terminal block GV1 G Set of 63 A busbars Set of 11 A busbars Set of S-shape busbars GV2 G24 GV2 G GV3 G GV3 G364 (1) 0.20 pp pp Protection accessories Description Use Sold in lots of Miniature control circuit fuse holder GV3 S Reference kg 1 LA9 D Sealing cover 1 LA9 D Safety cover 1 LAD 9ET LAD 9ET LAD 9ET Marking accessories Description Use Sold in lots of Sheet of 64 blank legends, (2) Sheet of 112 blank legends, (2) Sheet of 64 blank legends Sheet of 440 blank legends Marker holder Marker holder Bag of 300 blank legends SIS Label labelling software Mounting accessories Mounting plate Set of shims Size 4 Allen key, insulated, 1000 V Unit reference kg 10 LAD LAD LAD LAD LA9 D LAD LA9 D XBY 2U LAD 7X LA9 D730 1 LA9 D LAD ALLEN (1) With this set of busbars, any one contactor can be supplied directly by its EverLink double cage power terminal block. The other two contactors are supplied by the busbar set. The 11 A limitation is therefore applied to these two contactors. Example: 1 LC1 D6A supplied directly + 1 contactor LC1 D6A and 1 contactor LC1 D0 A supplied via the busbar set = 11 A. This combination is compatible with busbar set GV3 G364. /8

37 References For a contactors LC1 D09...D38 and LC1 DT20 DT y Control circuit voltage Uc Average resistance at 20 C ± 10 % Inductance of closed circuit Reference (1) V H kg 0/60 Hz LXD 1J (2) LXD 1Z LXD 1B LXD 1C LXD 1pp LXD 1CC LXD 1D LXD 1E LXD 1EE LXD 1K LXD 1F LXD 1FE LXD 1G LXD 1FC LXD 1L LXD 1LE LXD 1M7 (3) LXD 1P LXD 1U LXD 1W LXD 1Q7 (4) LXD 1V LXD 1N LXD 1R LXD 1T LXD 1S LXD 1SC LXD 1X LXD 1YC LXD 1Y (1) The last 2 digits in the reference represent the voltage code. (3) Suitable for use on 230 V (see pages /2 and /3). (4) Suitable for use on 400 V (see pages /2 and /3). /86

38 References For a contactors LC1 D40A D6A, LC1 DT60A and LC1 DT80A - - y Control circuit voltage Uc Average resistance at 20 C ± 10% Inductance of closed circuit Reference (1) V H kg 0/60 Hz LXD 3J (2) LXD 3B LXD 3C LXD 3D LXD 3E LXD 3pp LXD 3K LXD 3F LXD 3FE LXD 3G LXD 3FC LXD 3L LXD 3LE LXD 3M7 (3) LXD 3P LXD 3U LXD 3W LXD 3Q7 (4) LXD 3V LXD 3N LXD 3R LXD 3T LXD 3S LXD 3SC LXD 3X LXD 3YC LXD 3Y (1) The last 2 digits in the reference represent the voltage code. (2) This coil can only be used on 0 Hz. (3) Suitable for use on 230 V (see pages /2 and /3). (4) Suitable for use on 400 V (see pages /2 and /3). /87

39 References (continued) For 3 or 4-pole contactors LC1D40, D0, D6, D80, D9 - - y LX1 D6pp Control circuit voltage Uc Average resistance at 20 C ± 10 % Inductance of closed circuit Reference (1) Average resistance at 20 C ± 10 % Inductance of closed circuit Reference (1) V H H kg 0 Hz 60 Hz LX1 D6B LX1 D6B LX1 D6C LX1 D6D LX1 D6E 4.2 LX1 D6E LX1 D6F LX1 D6F LX1 D6FE LX1 D6G LX1 D6G LX1 D6L LX1 D6M / LX1 D6M LX1 D6P LX1 D6U LX1 D6U LX1 D6W LX1 D6W LX1 D6Q / LX1 D6Q LX1 D6V LX1 D6N LX1 D6R 19 LX1 D6R LX1 D6T LX1 D6S LX1 D6S LX1 D6X LX1 D6Y y 24 0/60 Hz LX1 D6B LX1 D6D LX1 D6E LX1 D6F LX1 D6FE LX1 D6G /230 (2) LX1 D6M LX1 D6P /240 (3) LX1 D6U /400 (4) 20 LX1 D6Q LX1 D6V LX1 D6N LX1 D6R (1) The last 2 digits in the reference represent the voltage code. (2) For use on 230 V This coil can be used on 240 V at 60 Hz. (3) This coil can be used on 220/240 V at 0 Hz and on 240 V only at 60 Hz. (4) For use on 400 V /88

40 References (continued) For 3 or 4-pole contactors LC1 D y LX1 D8pp Control circuit voltage Uc Average resistance at 20 C ± 10 % Inductance of closed circuit Reference (1) Average resistance at 20 C ± 10 % Inductance of closed circuit Reference (1) V H H kg 0 Hz 60 Hz LX1 D8B LX1 D8B LX1 D8C LX1 D8D LX1 D8E 0.28 LX1 D8E LX1 D8F LX1 D8F LX1 D8FE LX1 D8G LX1 D8FC LX1 D8L LX1 D8M LX1 D8M LX1 D8P LX1 D8U LX1 D8U LX1 D8W LX1 D8Q LX1 D8Q LX1 D8V LX1 D8N LX1 D8R LX1 D8R LX1 D8T LX1 D8S For 3 or 4-pole contactors LC1 D11, LC1 D y Control circuit voltage Uc Average resistance at 20 C ± 10 % Inductance of closed circuit Reference (1) Average resistance at 20 C ± 10 % Inductance of closed circuit Reference (1) V H H kg 0/60 Hz LX1 D8B LX1 D8C LX1 D8D LX1 D8E LX1 D8F LX1 D8FE LX1 D8G LX1 D8FC LX1 D8LE LX1 D8M LX1 D8P LX1 D8U LX1 D8UE LX1 D8Q LX1 D8V LX1 D8N LX1 D8R LX1 D8T LX1 D8S (1) The last 2 digits in the reference represent the voltage code. /89

41 References For 3-pole contactors LC1 D80 or 4-pole contactors LP1 D80 Control circuit voltage Uc Average resistance at 20 C ± 10% Inductance of closed circuit Reference (1) V H kg LX4 D7JD LX4 D7BD LX4 D7CD LX4 D7ED LX4 D7pD LX4 D7ND LX4 D7SD LX4 D7FD LX4 D7GD LX4 D7MD LX4 D7UD LX4 D7RD (1) The last 2 digits in the reference represent the voltage code. /90

42 References TeSys contactors For contactors LC1 D11, D10 Control circuit voltage Uc Average resistance at 20 C ± 10 % Inductance of closed circuit Reference (1) V H kg LX4 D8BD LX4 D8ED 60 LX4 D8ND LX4 D8SD LX4 D8FD LX4 D8GD LX4 D8MD LX4 D8pD LX4 D8UD LX4 D8RD For 3-pole contactors LC1 D80 or 4-pole contactors LP1 D80 Control circuit voltage Uc Average resistance at 20 C ± 10 % Inductance of closed circuit Reference (1) V H kg LX4 D7JW LX4 D7BW LX4 D7CW LX4 D7EW LX4 D7SW LX4 D7FW LX4 D7MW (1) The last 2 digits in the reference represent the voltage code. /91

2.3 LA1-DN10, DN01 LA6-DK LA8-DN LA1-DN LC1-LP1 LA8-DN LA1-DN, DC LA2-DT, DS LA3-DR LA1-DX, DY, DZ

2.3 LA1-DN10, DN01 LA6-DK LA8-DN LA1-DN LC1-LP1 LA8-DN LA1-DN, DC LA2-DT, DS LA3-DR LA1-DX, DY, DZ 110-17V AC-DC 50/60Hz E1 E LA1-DN10, DN01 0 LA6-DK LA6 DK10 LA8-DN LA1-DN.3 LA8-DN LC1-LP1 LA1-DN, DC LA-DT, DS LA3-DR LA1-DX, DY, DZ See right-hand page for mounting possibilities according to the contactor

More information

Contactors. d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. References

Contactors. d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. References d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. c Standard power ratings Rated Instantaneous Basic reference. Weight of 3-phase motors operational auxiliary

More information

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors 90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30 Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,

More information

Characteristics TeSys contactors 0 Model d

Characteristics TeSys contactors 0 Model d Charateristis TeSys ontators 0 Model d Contator type LC1 D09 D18 D25 D38 D40 D50 D95 D115 and D150 DT20 and DT25 DT32 and DT40 Environment Rated insulation voltage (Ui) Conforming to IEC 60947-4-1, V 690

More information

C -5 to +55 (0.8 to 1.1Uc) Permissible o

C -5 to +55 (0.8 to 1.1Uc) Permissible o T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC 60947-4

More information

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660 Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,

More information

5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors

5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors Contents 0 - Contactors Selection guides.............................................page /2 b General, selection of contactors....................... pages /16 k contactors and reversing contactors b

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

DATA SHEET LC-D CONTACTORS

DATA SHEET LC-D CONTACTORS Issued November 2009 DATA SHEET LC-D CONTACTORS Based on Shneider MKTED205103EN Catalogue Charateristis 5 d Contator type LC1 D09 D18 D25 D38 D40 D50 D95 D115 and D150 DT20 and DT25 DT32 and DT40 Environment

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

References 4 Fuse carriers

References 4 Fuse carriers References components 000_ -pole basic blocks Rating Cartridge fuse size umber of early break contacts () Single-phase protection device () Reference () Connection by spring terminals A 0 x 8 () Without

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

TeSys D Green. Catalogue 2017 AC/DC compatible coil contactors. schneider-electric.com

TeSys D Green. Catalogue 2017 AC/DC compatible coil contactors. schneider-electric.com TeSys D Green Catalogue 2017 AC/DC compatible coil contactors schneider-electric.com Green Premium TM Endorsing eco-friendly products in the industry Schneider Electric s Green Premium ecolabel is committed

More information

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com TeSys D, K Catalogue 2017 'S335' series contactors for electrodomestic applications schneider-electric.com Presentation TeSys D, TeSys K TeSys D, TeSys K: S335 series Best-in-class contactors for electrodomestic

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

Low Voltage. EasyPact TVS. Motor starters from 6A to 630A. Catalog 2015

Low Voltage. EasyPact TVS. Motor starters from 6A to 630A. Catalog 2015 Low Voltage EasyPact TVS Motor starters from 6A to 630A Catalog 2015 Designed for the essential EasyPact TVS General contents EasyPact TVS contactors, 6 A to 630 A A-1 EasyPact TVS thermal overload relays

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

Accessories for Contactors and Contactor Relays

Accessories for Contactors and Contactor Relays 4/0 Accessories for Contactors and Contactor Relays Contents Accessories for A... Series and BC... Series Contactors and for Contactor Relays Auxiliary Contact Blocks - Front Mounting... 4/2 Auxiliary

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information

Star Series Motor protection & control

Star Series Motor protection & control Contact us ABB Inc. Low Voltage Control Products 16250 W. Glendale Drive New Berlin, WI 53151 Phone: 888-385-1221 Fax: 800-726-41 USA Technical support & Customer Service: 888-385-1221, Option 4 7:30AM

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440

More information

LR9 F OVERLOAD RELAYS

LR9 F OVERLOAD RELAYS Issued November 2009 DATA SHEET LR9 F OVERLOAD RELAYS Based on Schneider MKTED2050EN Catalogue General 6 Motor protection Operating conditions There are many possible causes of electric motor failure.

More information

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC Product data sheet Characteristics LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 -

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC Product datasheet Characteristics LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 -

More information

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated 11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF

More information

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition Product datasheet Characteristics LC1F400E7 Complementary [Uimp] rated impulse withstand voltage Overvoltage category [Ith] conventional free air thermal current Main Range Product name Product or component

More information

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC Product datasheet Characteristics LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 -

More information

Auxiliary contact blocks - with spring terminals Accessories

Auxiliary contact blocks - with spring terminals Accessories Auxiliary contact blocks - with spring terminals Accessories CA3-10S 1SBC101037F0014 Description The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits. CA3

More information

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101428D0201 28/03/11 -.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)

More information

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction Introduction Introduction Schneider Electric offers a complete line of products for the manual control and protection of motors. This catalog covers those devices designed to meet IEC standards for protection

More information

Bulletin 100-D IEC Contactors

Bulletin 100-D IEC Contactors Bulletin 100-D IEC Contactors Electronic and conventional coils AC & DC Integrated PLC interface Low power pick-up & hold-in Wide voltage ranges Complete range of accessories Environmentally friendly Compact

More information

CI-TI Contactors and Motor Starters Type CI 6-50

CI-TI Contactors and Motor Starters Type CI 6-50 Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components

More information

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France Contact us ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F-69687 Chassieu cedex / France You can find the address of your local sales organisation on

More information

Thermal overload relays Type TA Class 10

Thermal overload relays Type TA Class 10 Thermal overload relays Type TA Class Thermal Overload relays Description Available for starter construction with A Line contactors and separate panel mounting Designed for close couple mounting Separate

More information

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line 2 Contactores Compactos CWC0 Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors

More information

Pendant control stations 6

Pendant control stations 6 Characteristics For control circuits Environment Conformity to standards EN/IEC 0-- EN/IEC 00-, UL 0, CSA C- n EN/IEC 0-- and EN/ISO 0: 00 for versions with trigger action Emergency stop Protective treatment

More information

3RT14 Contactors with 3 Main Contacts

3RT14 Contactors with 3 Main Contacts 3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Contactor Size 3RT14 46 Mechanical endurance Oper. 10 million Electrical endurance Oper. 0.5 million C-1 utilization category at I e

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

Industrial Switchgear New Products Catalogue Pole Switching with the DILMP Contactors

Industrial Switchgear New Products Catalogue Pole Switching with the DILMP Contactors Industrial Switchgear New Products Catalogue 2007 4 Pole Switching with the The complete range of contactors, efficient motorstarters and variable speed drives for the motor circuit. New simple to install

More information

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30 Contactors KNL KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30 Adaptable to various control requirements with ability of mounting from one to four additional auxiliary contacts. Versatile product capable

More information

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

Technical Information

Technical Information C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

40 Series - Miniature PCB relays A. Features

40 Series - Miniature PCB relays A. Features 1. = 12.4 1. = 12.4 1. = 12.4 40 Series - Miniature PCB relays 8-10 - 16 A Features 40.31 40.1 40.2 1 & 2 Pole relay range 40.31-1 Pole 10 A (3. mm pin pitch) 40.1-1 Pole 10 A ( mm pin pitch) 40.2-2 Pole

More information

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Data sheet CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Description Danfoss contactors CI 6-50 cover the power range 2.2-25 kw. CI 6 is built up as a combined contactor/control relay. CI 9

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

K30H001YP cam star-delta switch - 3-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4 CHAPTER ELECTRICAL 2 INSTALLATION Contents of this Chapter... 2.1 Warnings & Agency Approvals..................2 2 2.1.1 Isolation..............................................2 2 2.1.2 Electrical Power

More information

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.

More information

Series CA5 Contactors

Series CA5 Contactors Series C5 Contactors The contactor for heavy industrial applications from 500HP to 900HP DISCONTINUED This series is being replaced by the C9 Series of contactors C5 Series contactors provide large horsepower

More information

Contactor Types CI 61-98

Contactor Types CI 61-98 MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories

More information

Control stations and enclosures Pendant control stations, for control circuits Double insulated, type XAC-A

Control stations and enclosures Pendant control stations, for control circuits Double insulated, type XAC-A Characteristics Environment Conforming to standards IEC 947-5-1, EN 60947-5-1 Approvals Protective treatment NEMKO. Special version : UL Listed A600-Q600, CSA A600-Q600 Standard version : TH Ambient air

More information

Technical Information

Technical Information Miniature Technical Information -09-12 Rated Insulation Voltage U i to IEC947-1 [V] 690V UL/CS [V] 600V Rated Impulse Voltage Withstand U imp [kv] 6 Rated Voltage Ue-Main Contacts C 50/60Hz [V] 230, 240,

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

TeSys D Overload Relays

TeSys D Overload Relays TeSys D Contactors and Overload Relays TeSys D Overload Relays Table.24: TeSys D Overload Relays Ambient Compensated, Bimetallic, Direct Mounting Current Setting Range (A) For Direct Mounting to LC1...

More information

K50H004UP cam changeover switch - 4-pole A - screw mounting

K50H004UP cam changeover switch - 4-pole A - screw mounting Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h No Filter 81.6 % Auto 9.1 m3/h 250.0 m3/h Auto 99.7 m3/h 100.0 m3/h Auto 91.3 m3/h 92.0 m3/h Auto 40.0 m3/h 7. MW Auto 50.7 m3/h 50.0 m3/h 7.2 % Auto.6 % 45.0 % ABB NF Contactor Relays Overview...3 Ordering

More information

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC Characteristics time delay relay 2 functions - 0.02 s..300 h - 24..240 V AC - 2 OC Complementary Product front plate size Control type Housing material Main Range of product Product or component type Electrical

More information

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets 86 Series - Timer modules Features 86.00 86.30 Timer modules for use in conjunction with relay & socket. 86.00 - Multi-function & multi-voltage timer module 86.30 - Bi-function & multi-voltage timer module

More information

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1 Motor Contactor J7KN Range from 4 to 500 kw (AC 3, 380/415 V) AC and DC operated Integrated auxiliary contacts; integrated aux. contact of J7KN contactors up to 11kW suitable for electronic circuits Screw

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC Characteristics time delay relay 2 functions - 0.02 s..300 h - 24..240 V AC - 2 OC Main Range of product Product or component type Electrical connection Discrete output type Contacts type and composition

More information

60 Series - General purpose relays 6-10 A. Features SERIES

60 Series - General purpose relays 6-10 A. Features SERIES 60 Series - General purpose relays 6-10 60 SERIES Features 60.12 60.13 Plug-in mount 10 General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) C coils & DC coils

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

55 Series - Miniature General Purpose Relays 5-10 A

55 Series - Miniature General Purpose Relays 5-10 A Series - Miniature General Purpose Relays -0 A - Plug-in or P.C.B. versions - AC or DC coils - Lockable test button and mechanical flag indicator as standard on and CO relays types - Sockets and accessories:

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

6-3 [D5A0] WIRING DIAGRAM. 5. Wiring Diagram. 5. Wiring Diagram A: POWER SUPPLY ROUTING SU01-04A

6-3 [D5A0] WIRING DIAGRAM. 5. Wiring Diagram. 5. Wiring Diagram A: POWER SUPPLY ROUTING SU01-04A 6-3 [D5A0] WIRING DIAGRAM A: POWER SUPPLY ROUTING SU01-04A 12 WIRING DIAGRAM [D5A0] 6-3 SU01-04B 13 6-3 [D5A0] WIRING DIAGRAM No. Load No. Load MB-1 MB-2 MB-3 MB-4 MB-5 MB-6 MB-7 MB-8 MB-9 MB-10 SBF-7

More information

CO (DPDT) 16/25 250/ /440 2,000 4, /0.5/ /0.5/ (5/5) 300 (5/5) AgNi

CO (DPDT) 16/25 250/ /440 2,000 4, /0.5/ /0.5/ (5/5) 300 (5/5) AgNi 46 Series - Miniature industrial relays 8-16 A Features 46.52 46.61 1 & 2 Pole relay range 46.52-2 Pole 8 A 46.61-1 Pole 16 A Socket mount or direct connection via Faston connectors AC coils & DC coils

More information

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Presentation Soft starters 0 Altistart 48 soft start - soft stop units Presentation Soft starters 5 6 7 65_Ver.-EN.fm/ Presentation (continued) Soft starters Applications The Altistart 8 soft start - soft stop unit is a controller with 6 thyristors which is used for the torque-controlled

More information

ATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A

ATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A TyS t M - TyS g M utomatic Transfer Switching Equipment Transfer switches new The solution for > High Rise uildings > Data centre > Healthcare buildings TyS g M I-0-II P atys-mg_001_b_1_cat Function TyS

More information

Page 2-4 Page 2-8. Page Page 2-13

Page 2-4 Page 2-8. Page Page 2-13 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings in AC3 440V duty: 6 to 630A IEC Power ratings in AC3 400V duty:. to 335kW UL/CSA ratings: 3 to 500HP

More information

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads. C4 Miniature Contactors Contactors C4 Rated Insulation Voltage U i to IEC 947-1 [V] 500V UL/CS [V] 600V Rated Impulse Voltage U imp [kv] 8 Rated Voltage U e Main Contacts C 50/60Hz [V] 230, 240, 400, 415,

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals NSL..S 4-pole / 8-pole Contactor Relays - Spring DC Operated Description - 1-stack contactor relays: 4-pole, - 2-stack contactor relays: 8-pole, - Mechanically linked contact elements available, - Low

More information

AF09... AF96 3-pole contactors Accessory fitting details

AF09... AF96 3-pole contactors Accessory fitting details AF9... AF96 3-pole contactors Accessory fitting details Contactor and main accessories (other accessories available) AF9... AF65 AF contactor (without top mounted coil terminal block) VEM4 mechanical and

More information

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW) Product datasheet Characteristics ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/400...440V(45kW) Complementary Assembly style Function available Supply voltage limits Main Range of product

More information

Motor control The essential guide

Motor control The essential guide Motor control The essential guide Motor control TeSys Accurate and reliable control of motors TeSys range provide you more simplicity, compactness, openness and flexibility... so many evolutions and new

More information

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5- MKING MODERN LIVING POSSIBLE Technical brochure Minicontactors CI 5- www.danfoss.com 2 IC.PD.C10.F3.02-520B4167 Danfoss /S, C-SMC, mr, 07-2010 Contents Page Minicontactor CI 5- Introduction...............................................................................4

More information