Meta Solution. Contactors and Overload relays

Size: px
Start display at page:

Download "Meta Solution. Contactors and Overload relays"

Transcription

1 Meta Solution Contactors and Overload relays

2 New generation of Contactors from LS Industrial Systems Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series Sealed structure has improved its safety features so that no arc flash is exposed. In order to emphasize its durability as an industrial device, Metasol series adopt simple design form and sophisticated shape applying diamond cut concepts on product surface. LSIS META SOLUTION CONTACTORS

3 Contents Table of specifications 10 Type numbering system 12 Environment 14 Control coil characteristics 15 Marking 16 Internal structure 17 Contactors (18AF) 18 Contactors (22AF) 20 Contactors (40AF) 22 Contactors (65AF) 24 Contactors (100AF) 26 Motor starters 28 Reversing contactors 30 Capacitive contactors 31 Accessory Auxiliary contact units 32 Interlocks 34 Installation of Interlock and Wire kits 35 Surge unit 36 Capacitor unit 37 Replacement coils 38 Safety cover (Option) 39 Overload relays Genaral descriprions 40 Overload relay specifications 42 Overload relay operation 44 Separate mounting units 45 Remote reset units 46 Overload relay ordering types 48 Overload relay trip curves Class 10A, 18AF / Class 20, 18AF 52 Class 10A, 40AF / Class 20, 40AF 53 Class 10A, 65AF / Class 20, 65AF 54 Class 10A, 100AF / Class 20, 100AF 55 Dimension 56 Contact arrangement 69

4 Meta solution Performance Breaking capacity Optimum coordination Extensive applications

5 Metasol MC & MT series More Safety, More Value No arc exposure from the sealed structure Contactors & Overload Relays Ensure reliability in the system: TypeⅡCoordination Perfect system with peripheral devices. Environment friendly product: complies with International environment standard RoHS.

6 MC/ TOR 12Models in 4 Frames High reliability from optimum design MC 18M/MT 18M MC Rated current: 6, 9, 12, 18A Rated insulation voltage: 690V TypeⅡ: Max. MT Setting current: 0.1~18A Trip class: Class10, 20 MC 22a/MT 40a MC Rated current: 6, 9, 12, 18, 22A Rated insulation voltage: 690V TypeⅡ: Max. MT Setting current: 0.1~22A Trip class: Class10, 20

7 Advanced technology Expert solution High reliability of Open/Close operation by Arc Diagnosis System Optimum mechanical operation by analysis of pull-in force Minimum temperature increase by analysis of frame variation and air flux MC 100a/ MT 100a MC 65a/ MT 65a MC 40a/ MT 40a MC Rated current: 32, 40A Rated insulation voltage: 1000V TypeⅡ: Max. MT Setting current: 0.1~40A Trip class: Class10, 20 MC Rated current: 50, 65A Rated insulation voltage: 1000V TypeⅡ: Max. MT Setting current: 4~65A Trip class: Class10, 20 MC Rated current: 75, 85, 100A Rated insulation voltage: 1000V TypeⅡ: Max. MT Setting current: 7~100A Trip class: Class10, 20

8 MC/ TOR Accessories Perfect combination of peripheral devices and various accessories Offering economical solution with compact size & easy connection Perfect system with other devices and accessories One-touch connection Din Rail connection without any special tools Direct combine a surge unit Simple wiring Mounting unit, Adapter Reversing wire set Easy Maintenance 4-terminal type: Easy wiring of operation coil Module type of Screw terminal Interlock unit with built-in auxiliary contacts(2no built-in)

9 Variety Contactor Interlock unit Auxiliary contact unit - side mount Surge unit Wire kit Safety cover (Option) Auxiliary contact unit - front mount(2p) Auxiliary contact unit - front mount(4p) Direct adaptor to MMS Remote reset unit Overload relay Separete mounting unit Mounting unit for use with MMS

10 Table of specifications MC type Magnetic Contactors Frame size Type screws clamp terminals Number of poles Rated operational voltage, Ue Rated insulation voltage, Ui Rated frequency Rated impulse withstand voltage, Uimp Maximum operating rate in operating cycles per hour(ac3) Durability Mechanical Electrical Current AC-1, Thermal current A and AC-3 200/240V kw power A 380/440V kw A 500/550V kw A 690V kw A AC-4 200/240V kw A 380/440V kw A Size AC Weight kg and H control Size(W H D) mm weight DC Weight kg D W control Size(W H D) mm Auxiliary(standard) Auxiliary Side mount Front mount Note) Minimum conduct current of Auxiliary contactor is DC 17V 5mA. MT type Thermal Overload Relays 18AF MC-6M MC-9M MC-12M MC-18M 3pole 690V 690V 50/Hz 8kV 1800 operations per hour 15mil. operations 2.5mil. operations a or 1b UA-1 AU-2, AU-4 22AF MC-6a MC-9a MC-12a MC-18a MC-22a * 3pole 690V 690V 50/Hz 8kV 1800 operations per hour 15mil. operations 2.5mil. operations a1b UA-1 AU-2, AU-4 Type Screws clamp terminals Rated operational voltage, Ue Rated insulation voltage, Ui Rated impulse withstand voltage, Uimp Trip class Setting range Size Weight and weight H D W Size(W H D) kg mm MT-18M/ 690V 690V 6kV 10A, ~18A MT-40a/ 690V 690V 6kV 10A, ~40A * The safety cover of magnetic contactor ad thermal overload relay is optional. 10

11 40AF MC-32a MC-40a 3pole 690V 1000V 50/Hz 8kV 1800 operations per hour 12mil. operations 2mil. operations a2b UA-1 AU-2, AU-4 65AF MC-50a MC-65a 3pole 690V 1000V 50/Hz 8kV 1800 operations per hour 12mil. operations 2mil. operations a2b UA-1 AU-2, AU-4 100AF MC-75a MC-85a MC-100a 3pole 1000V 1000V 50/Hz 8kV 1800 operations per hour 12mil. operations 2mil. operations a2b UA-1 AU-2, AU-4 MT-40a/ 690V 690V 6kV 10A, ~40A 0.17 MT-65a/ 690V 690V 6kV 10A, 20 4~65A 0.31/0.33 MT-100a/ 690V 690V 6kV 10A, 20 7~95A 0.48/

12 Type numbering system Contactors / MC-6a / R AC220 Hz 1a1b Rated current Version Coil voltage Frequency Auxiliary contact 6a 6A - Standard AC 220 AC 220V Hz 00 None R Reversing 50 50Hz 11 1a1b 22 2a2b 100a 100A DC 24 DC 24V Note) See page 15 for details. Starters / / MS-6a R 2H AC220 Hz / Rated current Contactor version Relay version Coil voltage Frequency Auxiliary contact Relay setting current 6a 6A - Standard R Reversing 2H Non-differential (2-heater) AC 220 AC 220V Hz 50 50Hz 00 None 11 1a1b A 100a 100A 3H Non-differential (3-heater) DC 24 DC 24V 22 2a2b A 3K Differential Note) See page 15 for details. 3D Class 20 Thermal Overload Relay / MT-18a 2H 0.1 Frame size Relay version Relay setting current 18a 40a 18AF 40AF 2H Non-differential (2-heater) A 65a 100a 65AF 100AF 3H Non-differential (3-heater) A 3K Differential 3D Class 20 12

13 Optional Accessories Auxiliary contact unit UA1 11 Surge absorber US11 Composition and voltage Version Contact composition 1 Varistor+RC AC/DC 24~48V UA-1 Side mount 11 1NO+1NC 2 Varistor+RC AC/DC 100~125V AU-2 Front mount(2p) 20 2NO 3 Varistor+RC AC/DC 200~240V AU-4 Front mount(4p) 02 2NC 4 Varistor+RC AC 380~440V 40 4NO 5 Varistor+RC AC 24~48V 31 3NO+1NC 6 Varistor+RC AC 100~125V 22 2NO+2NC 11 Varistor AC 200~240V 13 1NO+3NC 12 Varistor DC 24~48V 04 4NC 13 Varistor DC 100~125V 14 Varistor DC 200~220V 22 RC AC 100~125V Interlock unit Wire kit for Interlocking Interlock set (UR+UW) Separate mounting unit (For relay) Remote reset unit (For relay) UR02 UW32 RK32 UZ32 UM Contact composition Frame size Frame size Frame size Cable length 02 2NC 18 18AF 32 32AF 32 32AF 4R None 32 32AF 63 63AF 63 63AF 5R AF 95 95AF 95 95AF 6R AF 13

14 Environment Environment Standards Certifications Rated insulation voltage (Ui) Rated impulse withstand voltage (Uimp) Degree of protection Ambient air temperature Operating altitude Operating positions IEC/EN 947-1, IEC/EN , UL508, K947 CE, UL, CCC 1000V 8kV IP20 (Conforming to IEC529) Storage : -50 C ~ +80 C Operation : -5 C ~ + C 3000m (8900ft) Shock resistance Opened: 8G (1/2 sine wave =11ms) Closed : 10G Vibration resistance (Conforming to IEC68-2-6) Opened : 2G ( Hz) Closed : 4G Flame resistance Conforming to UL 94: Vo Conforming to IEC : 9 C Connections Terminal Tightening torque Conductor (mm 2 /AWG) [Nm][Ib-in] MC-18a 1~6/18~10 1~6/18~10 1~6/18~ ~ ~1.2/ 7~10 MC-40a 1~6/18~10 1~6/18~10 1~6/ 0.75~4/ 0.8~2.5/ 1.25~5.5 18~10 18~10 7~ ~35/ 0.75~25/ 0.75~35/ 0.75~25/ 0.75~25/ 0.75~16/ MC-65a 18~2 18~4 18~2 18~4 18~4 18~ ~22 2.5~70/ 2.5~50/ 2.5~70/ 2.5~50/ 2.5~50/ 2.5~35/ MC-100a 12~2.0 12~1.0 12~2.0 12~1.0 12~1.0 10~ ~38 Aux. terminal 0.5~2.5/20~ ~2 1.25~3.5-3~4.5/ 26~39-4~6/ 35~53 12 [kgf cm] 14

15 Control coil characteristics Frame size 18AF 22AF 40AF 65AF 100AF Type AC coil Control voltage [Uc] 50Hz [V] Hz [V] Voltage limit [Uc] Operational Drop-out Coil consumption at 20 C AC 220V Inrush [VA] 50/Hz Holding [VA] Heat dissipation [W] Operating time Closing [ms] Opening [ms] DC coil Control voltage [Uc] Voltage limit [Uc] Operational Drop-out Coil consumption at 20 C DC 110V Inrush [W] Holding [W] Time constant (L/R) [ms] Operating time Closing [ms] Opening [ms] MC-6M MC-6a MC-32a MC-50a MC-75a MC-9M MC-9a MC-40a MC-65a MC-85a MC-12M MC-12a MC-100a MC-18m MC-18a MC-22a 24, 32, 36, 42, 48, 80, 100, 110, 220, 230, 240, 380, 400, 415, 440, 500, 550V 24, 48, 100, 110, 120, 200, 208, 220, 230, 240, 277, 380, 440, 480, 0V 85 ~110% (50Hz) 85 ~110% (Hz) 30 ~ % , 20, 24, 48,, 80, 100, 110, 125, 200, 220, ~ 110% 10 ~ 30% A1 A2 Line A1 A2 Load Note) A1(A2) in line side is internally connected to A1(A2) in load side. 15

16 Marking Coil terminal Terminal numbering for line side Main terminal Brand Type Holder Safety cover Company logo Terminal numbering for load side Upper frame Lower frame Fixing hole DIN rail mounter Name plate Upper cover Hole for side mounting accessory Seat for surge unit connection Company logo Product name Type Standard Rating Conductor size CE marking UL rating UL mark Serial no. Country of origin Manufacturer 16

17 Internal structure Safety cover Arc chamber Screw terminal kit Upper frame Screw terminal kit Fixed contact Holder Moving contact Moving core Back spring Coil Ass y Fixed core Rubber Lower frame 17

18 Contactors (18AF) Description - 3-pole(NO) main contact - Finger proof design - DIN rail or screw mountable - AC or DC control in different physical size - Front/side mountable accessories available - Direct mountable overload relay available Rating MC-18M Rating Conductor type MC-6M MC-9M MC-12M MC-18M kw A kw A kw A kw A AC duty AC3 200/240V /440V /550V V AC4 200/240V /440V AC DC1 duty 2-pole 24V (L/R=1ms) in series 48V V pole 24V in series 48V V DC2, 4 duty 2-pole 24V (L/R=15ms) in series 48V V pole 24V in series 48V V Directly mountable Overload relay MT-40a Conductor size (solid, stranded) AWG 18~10 16~10 16~8 14~8 (the max. number of conducts : 2) mm 2 1~4 1.5~4 1.5~10 2.5~10 Contactor type 65/75 Cu-wire only 2-pole in series 3-pole in series Coil voltage AC 50Hz 24, 32, 42, 48, 80, 100, 110, 220, 230, 240, 380, 400, 500, 550V Hz 24, 48, 110, 110, 12, 200, 208, 220, 230, 240, 277, 380, 480, 0V DC DC 12, 20, 24, 48,, 80, 100, 110, 125, 200, 220, 250V Certification CE(IEC) UL508 CCC 18

19 Accessories Surge unit, US connecting to coil terminals 36 page Wire kit, UW for use with Interlock unit 34 page Interlock unit, UR side mount 34 page Auxiliary contact unit, UA1 side mount, 1NO+1NC 32 page Auxiliary contact unit, AU-4 front mount, 4P 32 page Auxiliary contact unit, AU-2 front mount, 2P 32 page Safety cover, A7 39 page Overload relay, MT directly mountable to MC type contactor 40 page 19

20 Contactors (22AF) Description - 3-pole(NO) main contact - Finger proof design - DIN rail or screw mountable - AC or DC control in different physical size - Front/side mountable accessories available - Direct mountable overload relay available Rating MC-22a Rating Conductor type MC-6a MC-9a MC-12a MC-18a MC-22a kw A kw A kw A kw A kw A AC duty AC3 200/240V /440V /550V V AC4 200/240V /440V AC DC1 duty 2-pole 24V (L/R=1ms) in series 48V V pole 24V in series 48V V DC 2,4 duty 2-pole 24V (L/R=15ms) in series 48V V pole 24V in series 48V V Directly mountable Overload relay MT-40a Conductor size (solid, stranded) AWG 18~10 16~10 16~8 14~8 14~8 (the max. number of conducts : 2) mm 2 1~4 1.5~4 1.5~10 2.5~10 2.5~10 Conductor type 65/75 Cu-wire only 2-pole in series 3-pole in series Coil voltage AC 50Hz 24, 32, 42, 48, 80, 100, 110, 220, 230, 240, 380, 400, 500, 550V Hz 24, 48, 110, 110, 12, 200, 208, 220, 230, 240, 277, 380, 480, 0V DC DC 12, 20, 24, 48,, 80, 100, 110, 125, 200, 220, 250V Certification CE(IEC) UL508 CCC 20

21 Accessories Surge unit, US connecting to coil terminals 36 page Wire kit, UW for use with Interlock unit 34 page Interlock unit, UR side mount 34 page Auxiliary contact unit, UA1 side mount, 1NO+1NC 32 page Auxiliary contact unit, AU-4 front mount, 4P 32 page Auxiliary contact unit, AU-2 front mount, 2P 32 page Safety cover, A7 39 page Overload relay, MT directly mountable to MC type contactor 40 page 21

22 Contactors (40AF) Description - 3-pole(NO) main contact - Finger proof design - DIN rail or screw mountable - AC or DC control in different physical size - Front/side mountable accessories available - Direct mountable overload relay available Rating MC-40a Rating Conductor type MC-32a MC-40a kw A kw A AC duty AC3 200/240V /440V /550V V AC4 200/240V /440V AC1 50 DC1 2-pole 24V (L/R=1ms) in series 48V V pole 24V in series 48V V DC2,4 2-pole 24V (L/R=15ms) in series 48V V pole 24V in series 48V V Directly mountable Overload relay MT-40a Conductor size (solid, stranded) AWG 12~8 10~6 (the max. number of conducts : 2) mm 2 2.5~10 4~16 Conductor type 65/75 Cu-wire only 2-pole in series 3-pole in series Coil voltage AC 50Hz 24, 32, 42, 48, 80, 100, 110, 220, 230, 240, 380, 400, 500, 550V Hz 24, 48, 110, 110, 12, 200, 208, 220, 230, 240, 277, 380, 480, 0V DC DC 12, 20, 24, 48,, 80, 100, 110, 125, 200, 220, 250V Certification CE(IEC) UL508 CCC 22

23 Accessories Surge unit, US connecting to coil terminals 36 page Wire kit, UW for use with Interlock unit 34 page Interlock unit, UR side mount 34 page Auxiliary contact unit, UA1 side mount, 1NO+1NC 32 page Auxiliary contact unit, AU-4 front mount, 4P 32 page Auxiliary contact unit, AU-2 front mount, 2P 32 page Safety cover, A7 39 page Overload relay, MT directly mountable to MC type contactor 40 page 23

24 Contactors (65AF) Description - 3-pole(NO) main contact - Finger proof design - DIN rail or screw mountable - AC or DC control in different physical size - Front/side mountable accessories available - Direct mountable overload relay available Rating MC-65a Rating Conductor type MC-50a MC-65a kw A kw A AC duty AC3 200/240V /440V /550V V AC4 200/240V /440V AC DC1 duty 2-pole 24V (L/R=1ms) in series 48V V pole 24V in series 48V V 80 DC2, 4 duty 2-pole 24V (L/R=15ms) in series 48V V pole 24V in series 48V V Directly mountable Overload relay MT-65a Conductor size (solid, stranded) AWG 10~4 8~3 (the max. number of conducts : 2) mm 2 6~25 10~35 Conductor type 65/75 Cu-wire only Coil voltage AC 50Hz 24, 32, 42, 48, 80, 100, 110, 220, 230, 240, 380, 400, 500, 550V Hz 24, 48, 110, 110, 12, 200, 208, 220, 230, 240, 277, 380, 480, 0V DC DC 12, 20, 24, 48,, 80, 100, 110, 125, 200, 220, 250V Certification CE(IEC) UL508 CCC 24

25 Accessories Surge unit, US connecting to coil terminals 36 page Wire kit, UW for use with Interlock unit 34 page Interlock unit, UR side mount 34 page Auxiliary contact unit, UA1 side mount, 1NO+1NC 32 page Auxiliary contact unit, AU-4 front mount, 4P 32 page Auxiliary contact unit, AU-2 front mount, 2P 32 page Overload relay, MT directly mountable to MC type contactor 40 page Safety cover, A7 39 page 25

26 Contactors (100AF) Description - 3-pole(NO) main contact - Finger proof design - DIN rail or screw mountable - AC or DC control in different physical size - Front/side mountable accessories available - Direct mountable overload relay available Rating MC-100a Rating Conductor type MC-75a MC-85a MC-100a kw A kw A kw A AC duty AC3 200/240V /440V /550 V V AC4 200/240V /440V AC DC1 duty 2-pole 24V (L/R=1ms) in series 48V V pole 24V in series 48V V DC2, 4 duty 2-pole 24V 55 (L/R=15ms) in series 48V V pole 24V in series 48V V 55 Directly mountable Overload relay MT-100a Conductor size (solid, stranded) AWG 8~2 8~00 8~00 (the max. number of conducts : 2) mm 2 10~35 10~50 10~50 Conductor type 65/75 Cu-wire only Coil voltage AC 50Hz 24, 32, 42, 48, 80, 100, 110, 220, 230, 240, 380, 400, 500, 550V Hz 24, 48, 110, 110, 12, 200, 208, 220, 230, 240, 277, 380, 480, 0V DC DC 12, 20, 24, 48,, 80, 100, 110, 125, 200, 220, 250V Certification CE(IEC) UL508 CCC 26

27 Accessories Surge unit, US connecting to coil terminals 36 page Wire kit, UW for use with Interlock unit 34 page Interlock unit, UR side mount 34 page Auxiliary contact unit, UA1 side mount, 1NO+1NC 32 page Auxiliary contact unit, AU-4 front mount, 4P 32 page Auxiliary contact unit, AU-2 front mount, 2P 32 page Safety cover, A7 39 page Overload relay, MT directly mountable to MC type contactor 40 page 27

28 Motor starters Description - Opened direct motor starter - 3-pole(NO) main contact - Finger proof design - DIN rail or screw mountable - AC or DC control contactor selectable - Front/side mountable accessories available - Overload relay is directly mounted to the contactor Rating Starter type screws clamp terminals AC duty AC3 200/ / / AC4 200/ /440 AC1 DC1 duty 2-pole 24V (L/R=1ms) in series 48V 110V 3-pole 24V in series 48V 110V DC2,4 duty 2-pole 24V (L/R=15ms) in series 48V 110V 3-pole 24V in series 48V 110V Combined devices Contactor Overload Non-differential relay (2-heater) Non-differential (3-heater) Differential (Class 10A) Differential (Class 20) MS-6M MS-9M MS-12M MS-18M kw A kw A kw A kw A MC-6M MC-9M MC-12M MC-18M MT-18/2H 0.1~18 MT-18/3H 0.1~18 MT-18/3K 0.1~18 MT-18/3D 1~18 MS-6a MS-9a MS-12a MS-18a MS-22a kw A kw A kw A kw A kw A MC-6a MC-9a MC-12a MC-18a MC-22a MT-40/2H 0.1~40 MT-40/3H 0.1~40 MT-40/3K 0.1~40 MT-40/3D 1~40 Coil voltage 2-pole in series 3-pole in series AC 50Hz 24, 32, 42, 48, 80, 100, 110, 220, 230, 240, 380, 400, 500, 550V Hz 24, 48, 110, 110, 12, 200, 208, 220, 230, 240, 277, 380, 480, 0V DC DC 12, 20, 24, 48,, 80, 100, 110, 125, 200, 220, 250V Certification CE(IEC) UL508 CCC 28

29 MS-32a MS-40a kw A kw A MC-35a MC-40a MT-40/2H 0.1~40 MT-40/3H 0.1~40 MT-40/3K 0.1~40 MT-40/3D 1~40 MS-50a MS-65a kw A kw A MC-50a MC-65a MT-65/2H 4~65 MT-65/3H 4~65 MT-65/3K 4~65 MT-65/3D 4~65 MS-75a MS-85a MS-100a kw A kw A kw A MC-75a MC-85a MC-100a MT-100/2H 7~100 MT-100/3H 7~100 MT-100/3K 7~100 MT-100/3D 7~100 Circuit diagram A1 A R/1/L1 S/3/L2 T/5/L A1 A /T1 4/T2 6/T

30 111NC 121NC 122NC 112NC Reversing contactors Description Circuit diagram -Two AC or DC control contactors are interlocked mechanically and electrically - 3-pole(NO) main contact in each contactor - Finger proof design - DIN rail or screw mountable - Front/side mountable accessories available - Overload relay can be directly mounted to the contactor if necessary A1 A1 A2 A2 R/1/L1 S/3/L2 T/5/L3 U/2/T1 V/4/T2 W/6/T3 R/1/L1 S/3/L2 T/5/L3 U/2/T1 V/4/T2 W/6/T3 A1 A1 A2 A2 Rating AC-3 duty Current (AC3) Weight MC-40a/R Type (AC control) 415V 440V 500V 690V 440V 240V 400V kw kw kw kw kw kw A g MC-6M/R MC-9M/R MC-12M/R MC-18M/R MC-6a/R MC-9a/R MC-65a/R MC-12a/R MC-18a/R MC-22a/R MC-32a/R MC-40a/R MC-50a/R MC-65a/R MC-75a/R MC-85a/R MC-100a/R MC-100a/R Coil voltage AC 50Hz 24, 32, 42, 48, 80, 100, 110, 220, 230, 240, 380, 400, 500, 550V Hz 24, 48, 110, 110, 12, 200, 208, 220, 230, 240, 277, 380, 480, 0V DC DC 12, 20, 24, 48,, 80, 100, 110, 125, 200, 220, 250V Certification CE(IEC) UL508 CCC 30

31 Capacitive contactors Description Capacitor unit(pre-loading resistor) is connected to the terminals of the contactor to reduce the high inrush current exceeding 20xIn. - AC or DC control coil on selection - 3-pole(NO) main contact - Finger proof design - DIN rail or screw mountable Rating Maximum operating power (kvar) Type Rated current Capacitor 220 ~ 400 ~ 0 ~ (A) unit type 240V 440V 550V MC-9a(D) AC-9 MC-12a(D) AC-9 MC-18a(D) AC-9 MC-22a(D) AC-9 MC-32a(D) AC-9 MC-40a(D) AC-9 MC-50a(D) AC-50 MC-65a(D) AC-50 MC-75a(D) AC-50 MC-85a(D) AC-50 MC-100a(D) AC-50 Note) - When the switch is closed condenser must be discharged before recharged. (Maximum residual voltage at terminals 50V) -To prevent short current, gg type fuse must be 1.5~2 times than rated current. Coil voltage AC 50Hz 24, 32, 42, 48, 80, 100, 110, 220, 230, 240, 380, 400, 500, 550V Hz 24, 48, 110, 110, 12, 200, 208, 220, 230, 240, 277, 380, 480, 0V DC DC 12, 20, 24, 48,, 80, 100, 110, 125, 200, 220, 250V These capacitive contactors are suitable for switching single-step or multiple-step condenser bank. It is standardized by IEC , UL and CSA. Features of capacitor unit(pre-loading resistor) - Damping resister that can limit the inrush current upto xin is connected to the mechanism that closed earlier than the main contact of the contactor - No heat loss by the serial resistor - Eliminate the switching surge -Improving the performance of the capacitor system T1 Power transformer MCCB Capacitor unit Condenser bank Heating coil or motor Capacitive contactors Example 31

32 Accessory Auxiliary contact units - Side or front mountable unit - Common use for all Metasol contactors UA-1 UA-1 AU-2 AU-4 Rating for UA-1 Rated operation voltage (Ue) 0V Rated insulation voltage (Ui) 0V Rated impulse withstand voltage (Uimp) 6kV Rated frequency 50/Hz Contact sensibility Voltage DC 17V Current DC 5mA Rated thermal current (Ith, AC12 duty) 10A Rated operation current AC15 duty 120V 6A (A0) 240V 3A 380V 1.9A 480V 1.5A 500V 1.4A 0V 1.2A DC13 duty 125V 1.1A (P0) 250V 0.55A 400V 0.31A 500V 0.27A 0V 0.2A Electrical lifetime AC15 duty 220V 0.5 mil. operations 440V 0.5 mil. operations DC13 duty 220V 0.5 mil. operations 440V 0.5 mil. operations Maximum operating cycles per hour 1800 operations per hour Conductor size (Solid, stranded) AWG 18~10 (the max. number of conducts : 2) mm 2 1~2.5 32

33 Selection Type Appearance Pole Composition NO NC Contact arrangement Mount Weight(g) 13(43) 21(31) UA Side 53 1NO1NC 2 - AU Front (44) 22(32) NO 1NO1NC 2NC NO 3NO1NC 2NO2NC AU Front NO3NC 4NC Installation UA-1 1 AU-2, To install side mounting unit remove the indicated part in the circle in the fig. first. And then fit each part as shown. To separate push forward and pull. To install front mounting unit fit it on the upper part of the front of the contactor and push it down. To separate pull the lever of the unit and push the unit upward. Maximum combination of contact units For contactors with AC coils AU-4(on front)+ua-1 4EA (2EA on both sides) AU-2(on front)+ua-1 4EA (2EA on both sides) For contactors with DC coils AU-4(on front)+ua-1 2EA (1EA on both sides) AU-2(on front)+ua-1 2EA (1EA on both sides) 33

34 Accessory Interlocks Component parts for assembling by customer Interlock unit, UR-02 UR-02 is a mechanical interlock unit and provides 2NC contacts for use in electrical interlocking Interlock unit Wire kit, UW UW is used for making reversing circuit between two contactors. Wire kit Wire kit Contactor Type Weight g MC-6a~22a UW MC-25a~40a UW MC-50a, 65a UW MC-75a~100a UW Interlock unit Weight Type g UR Rated operation voltage 0V Rated insulation voltage 0V Rated frequency 50/Hz Rated thermal current 10A Rated operation current AC15 duty 120V 6A (A0) 240V 3A 380V 1.9A 480V 1.5A 500V 1.4A 0V 1.2A DC13 duty 125V 0.55A (Q300) 250V 0.27A 34

35 Installation of Interlock and Wire kits 2 1 Click Install the interlock unit on the side of a contactor first. Fit each part as indicated in the fig. 1 Click 2 And then install the other contactor on the other side of the interlock unit as shown. After installing interlock unit wiring kit can be assembled. Wiring kit contains two molded wires - one for line side and the other for load side. Refer to below circuit diagram before assembling. A1 A2 R/1/L1 S/3/L2 T/5/L3 111NC 121NC R/1/L1 S/3/L2 T/5/L3 A1 A2 A1 A2 122NC 112NC A1 A2 U/2/T1 V/4/T2 W/6/T3 U/2/T1 V/4/T2 W/6/T3 Typical circuit diagram for reversing contactor 35

36 Accessory Surge unit It absorbs the surge arisen out of the coil of the contactor. It can be installed simply to the contactor. - Rated operation voltage (Ue) : AC 24 ~ 440V DC 24 ~ 125V - Rated insulation voltage (Ui) : 1000V - Rated impulse withstand voltage (Uimp) : 8kV - Degree of protection : IP20 MC Varistor C R US-1~6 MC Varistor US-11~14 Surge unit Internal elements spec. Weight Rated voltage Type Composition V R C g US-1 Varistor+RC 24~48V 120V 100Ϊ 0.1μF US-2 Varistor+RC AC 100~125V 270V 100Ϊ 0.1μF US-3 Varistor+RC 200~240V 470V 100Ϊ 0.1μF US-4 Varistor+RC 24~48V 120V 100Ϊ 0.47μF US-5 Varistor+RC DC 100~125V 270V 100Ϊ 0.47μF US-6 Varistor+RC 200~220V 470V 100Ϊ 0.47μF 29 US-11 Varistor 24~48V 120V - - US-12 Varistor AC/DC 100~125V 270V - - US-13 Varistor common 200~240V 470V - - US-14 Varistor 380~440V 1000V - - US-22 RC AC 100~125V - 56Ϊ 1μF MC C R Installation US-22 Click Connect the lead wires to the coil terminals of the contactor first. And then insert the body into the space of the contactor as shown above. 36

37 Capacitor unit Capacitor unit is connected to the terminals of the contactor to reduce the high inrush current. Maximum operating power (kvar) Rated current Type Contactor 220 ~ 400 ~ 0 ~ (A) 240V 440V 550V MC-9a(D) MC-12a(D) AC-9 MC-18a(D) MC-25a(D) MC-32a(D) MC-40a(D) MC-50a(D) MC-65a(D) AC-50 MC-75a(D) MC-85a(D) MC-100a(D) Note) - When the switch is closed condenser must be discharged before recharged. (Maximum residual voltage at terminals 50V) - To prevent short current, gg type fuse must be 1.5~2 times than rated current. Features of capacitor unit (Pre-loading resistor) - Damping resister that can limit the inrush current upto xin is connected to the mechanism that closed earlier than the main contact of the contactor - No heat loss by the serial resistor - Eliminate the switching surge - Improving the performance of the capacitor system Operation sequence Capacitor unit : OFF Contactor : OFF Capacitor unit : ON Contactor : OFF Capacitor unit : OFF Contactor : ON Capacitor unit Capacitor unit Capacitor unit Contactor Contactor Contactor Fig.1 Fig.2 Fig.3 Note) Closing sequence : Fig.1 => Fig.2 => Fig.3 Opening sequence : Fig.3 => Fig.1 37

38 Accessory Replacement coils To replace the existing coil to change voltage or repair. Coil voltage Contactor DC coil AC coil AC Hz (V) AC 50Hz (V) DC (V) MC-6M MC-9M MC-12M MC-18M MC-6a MC-9a MC-12a MC-18a MC-22a MC-32a MC-40a MC-50a MC-65a MC-75a MC-85a MC-100a Replacement process 38

39 Safety cover (Option) To prevent arc from coming out from the contactor To protect from unintended manual operation To prevent dust from entering into the inside of the contactor Type Contactor AP-9 All types 39

40 Overload relays General descriptions Type MT, bimetal-style, overload relays are designed to protect AC circuits and motors against overloads, phase failure, long starting times and prolonged stalling of the motor. Four versions are available according to the protection function and trip class as below. 1. Non-differential : 3pole-2bimetal(heater) and trip class 10A 2. Non-differential : 3pole-3bimetal(heater) and trip class 10A 3. Differential : 3pole-3bimetal(heater) and trip class 10A 4. Differential : 3pole-3bimetal(heater) and trip class 20 Configuration of the front Upstream connections Circuit identification Relay type Trip indicator Protection cover Adjustment dial Sealing the protection cover Stop/Test button Reset button/selector (manual or automatic reset) Auxiliary contacts(1no+1nc) Downstream connections MT-18M MT-40a MT-65a MT-100a Screw Screw Screw Screw 40

41 Contactors directly mountable with overload relays Overload relay Contactor Type Setting range Type MC-6M MT-18M 0.1~18A MC-9M MC-12M MC-18M MC-6a MC-9a MC-12a MT-40a 0.1~22A MC-18a MC-22a MC-32a MC-40a MT-65a 4~65A MC-50a MC-65a MC-75a MT-100a 7~100A MC-85a MC-100a MS-12 MS-40 MS-65 MS-100 Environment and auxiliary circuit Environment Standards Certifications Rated operation voltage Rated insulation voltage Rated frequency Degree of protection (Conforming to IEC 529) Ambient air temperature Storage Operation Mounting position Shock resistance (Conforming to IEC ) Vibration resistance (Conforming to IEC68-2-6) Insulation strength (Conforming to IEC 255-5) Rated impulse withstand voltage (Conforming to IEC 801-5) Auxiliary contacts characteristics Composition Rated thermal current Rated operation current AC15 duty 120V (C0) 240V 380V 480V 500V 0V DC13 duty 120V (R300) 240V Connecting conductor Size Connection to screw clamp terminals Type IEC/EN 947-1, IEC/EN CE, CSA, UL Max. 690V 690V 50/Hz IP ~ +80 C -5 ~ + C Vertical plane 15gn - 11ms 6G 6kV 6kV 1a1b (1NO +1NC) 5A C0, R A 0.75A 0.47A 0.375A 0.35A 0.3A 0.22A 0.1A 18AWG /1mm2 65/75 Cu-wire 41

42 Overload relay specifications MT type Thermal Overload Relays MT-18M/3K Frame size Trip class Type Non-differential(3P-2 heater) Non-differential(3P-3 heater) Differential type Terminal type Number of poles Rated operational voltage (Ue) Rated insulation voltage (Ui) Rated impulse voltage (Uimp) Degree of protection (IEC 529) Temperature compensation ( C) Functions Trip indicating Stop Test Manual/Automatic Reset Setting range(a) Nominal Wire size current rating mm 2 AWG ~1.5 18~ ~2.5 16~ ~ ~4 12~ ~ ~10 10~8 34 6~10 10~ ~25 6~ ~35 4~3 Applied contactors Separate mounting unit 18AF 10A 20 MT-18M/2H MT-18M/3H MT-18M/3K MT-18M/3D Screw clamp 3 690V Up to 690V 6kV IP 20-5~ ~18A 1~18A 0.1~ ~ ~ ~ ~1 1~1.6 1~ ~ ~ ~4 2.5~4 4~6 4~6 5~8 5~8 6~9 6~9 7~10 7~10 9~13 9~13 12~18 12~18 MC-6M, 9M, 12M, 18M - 42

43 MT-40a/3K MT-65a/3K S MT-100a/3K S 40AF 65AF 100AF 10A 20 10A 20 MT-40a/2H MT-65a/2H S MT-40a/3H MT-65a/3H S MT-40a/3K MT-40/3D MT-65a/3K S MT-65/3D S Screw clamp Screw clamp V 690V Up to 690V Up to 690V 6kV 6kV IP 20 IP 20-5~+40-5~ ~40A 1~40A 4~65A 10A 20 MT-100a/2H S MT-100a/3H S MT-100a/3K S MT-100/3D S Screw clamp 3 690V Up to 690V 6kV IP 20-5~+40 7~100A 0.1~ ~ ~ ~ ~1 1~1.6 1~ ~ ~ ~4 2.5~4 4~6 4~6 4~6 4~6 5~8 5~8 5~8 5~8 6~9 6~9 6~9 6~9 7~10 7~10 7~10 7~10 9~13 9~13 9~13 9~13 12~18 12~18 12~18 12~18 16~22 16~22 16~22 16~22 18~25 18~25 18~25 18~25 22~32 22~ ~36 24~36 28~40 28~40 28~40 28~40 34~50 34~50 45~65 45~65 MC-6a, 9a, 12a, 18a, 22a, 35a, 40a MC-50a, 65a UZ-32 UZ-63/S 7~10 7~10 9~13 9~13 12~18 12~18 16~22 16~22 18~25 18~ ~36 24~36 28~40 28~40 34~50 34~50 45~65 45~65 54~75 54~75 63~85 63~85 70~95 70~95 80~100 80~100 MC-75a, 85a, 100a UZ-95/S 43

44 Overload relay operation 1. Adjustment dial Before adjusting the dial open the protection cover. Current setting can be done easily by using (+) or (-) driver. Do not rotate the dial out of the setting range. 2. Stop/Test button STOP function is executed by pushing the button, which causes the next sequence. In case of operation test pull this button. 3.Trip indicator If relay is tripped it comes out. 4. Reset button/selector Manual mode Automatic mode Using a driver the reset mode can be set. In case of Manual mode(h) push the button to reset the relay. To change to Automatic mode(a) from Manual mode push the button and rotate as shown in the fig. 5.Auxiliary contact operation Terminal no. Normal STOP TEST/TRIP RESET NC NO

45 Accessories for overload relay Separate mounting units These accessories are used to mount the relays separately from contactors. If a relay is combined with a unit, it can be mounted on DIN rail or panel by fixing screws. Relay Type Unit Weight MT-18M/2H MT-18M/3H MT-18M/3K AZ-12MH 20g MT-18M/3D MT-40a/2H MT-40a/3H MT-40a3K UZ-32 23g MT-40a/3D MT-65a/2H S MT-65a/3H S MT-65a/3K S UZ-63/S 68g MT-65a/3D S MT-100a/2H S MT-100a/3H S MT-100a/3K S UZ-95/S 134g MT-100a/3D S 45

46 Accessories for overload relay Remote reset units These accessories are used to reset the relays on the panel door. Type UM-4R UM-5R UM-6R Cable length (L) 400 mm 500 mm 0 mm 1. Make the reset bar straight at least 55mm from the panel door and 35mm from the bracket. 2. The bending radius of the flexible reset bar should not be less than 15mm R15 10 Bracket Reset bar Panel door 8 Door hole cutting 46

47 Installation 1. Fit the bracket with the relay as indicated(*1) below. 2. Separate Nut(*3) and Head cap(*4) from the reset bar first. Insert the reset bar into the panel hole and then fix it with the Nut and Head. 3. To separate the bracket from the relay lift the *2 part as shown in the fig. 32AF 63AF 95AF Reset bar 8 *3 *4 Bracket Panel door *1 *2 47

48 Overload relay ordering types Trip class 10A Direct mounting type ARC Setting range (A) Non-differential (3P-2 heater) Ordering type Non-differential (3P-3 heater) Differential Contactor Separate mounting unit 0.1~0.16 MT-18M/2H0.14 MT-18M/3H0.14 MT-18M/3K ~0.25 MT-18M/2H0.21 MT-18M/3H0.21 MT-18M/3K ~0.4 MT-18M/2H0.33 MT-18M/3H0.33 MT-18M/3K ~0.63 MT-18M/2H0.52 MT-18M/3H0.52 MT-18M/3K ~1 MT-18M/2H0.82 MT-18M/3H0.82 MT-18M/3K0.82 1~1.6 MT-18M/2H1.3 MT-18M/3H1.3 MT-18M/3K1.3 MC-6M MT-18M/ 1.6~2.5 MT-18M/2H2.1 MT-18M/3H2.1 MT-18M/3K ~4 MT-18M/2H3.3 MT-18M/3H3.3 MT-18M/3K3.3 MC-9M MC-12M AZ-12MH 4~6 MT-18M/2H5 MT-18M/3H5 MT-18M/3K5 MC-18M 5~8 MT-18M/2H6.5 MT-18M/3H6.5 MT-18M/3K6.5 6~9 MT-18M/2H7.5 MT-18M/3H7.5 MT-18M/3K7.5 7~10 MT-18M/2H8.5 MT-18M/3H8.5 MT-18M/3K8.5 9~13 MT-18M/2H11 MT-18M/3H11 MT-18M/3K11 12~18 MT-18M/2H15 MT-18M/3H15 MT-18M/3K15 Setting range (A) Non-differential (3P-2 heater) Ordering type Non-differential (3P-3 heater) Differential Contactor Separate mounting unit 0.1~0.16 MT-40a/2H0.14 MT-40a/3H0.14 MT-40a/3K ~0.25 MT-40a/2H0.21 MT-40a/3H0.21 MT-40a/3K ~0.4 MT-40a/2H0.33 MT-40a/3H0.33 MT-40a/3K ~0.63 MT-40a/2H0.52 MT-40a/3H0.52 MT-40a/3K ~1 MT-40a/2H0.82 MT-40a/3H0.82 MT-40a/3K0.82 MT-40a/ 1~1.6 MT-40a/2H1.3 MT-40a/3H1.3 MT-40a/3K ~2.5 MT-40a/2H2.1 MT-40a/3H2.1 MT-40a/3K ~4 MT-40a/2H3.3 MT-40a/3H3.3 MT-40a/3K3.3 4~6 MT-40a/2H5 MT-40a/3H5 MT-40a/3K5 5~8 MT-40a/2H6.5 MT-40a/3H6.5 MT-40a/3K6.5 6~9 MT-40a/2H7.5 MT-40a/3H7.5 MT-40a/3K7.5 7~10 MT-40a/2H8.5 MT-40a/3H8.5 MT-40a/3K8.5 9~13 MT-40a/2H11 MT-40a/3H11 MT-40a/3K11 MC-6a MC-9a MC-12a MC-18a MC-22a MC-32a MC-40a UZ-32 12~18 MT-40a/2H15 MT-40a/3H15 MT-40a/3K15 16~22 MT-40a/2H19 MT-40a/3H19 MT-40a/3K19 18~25 MT-40a/2H21.5 MT-40a/3H21.5 MT-40a/3K ~32 MT-40a/2H27 MT-40a/3H27 MT-40a/3K27 28~40 MT-40a/2H34 MT-40a/3H34 MT-40a/3K34 UZ-32(34A) 48

49 Trip class 10A Direct mounting type ARC Setting range (A) Non-differential (3P-2 heater) Ordering type Non-differential (3P-3 heater) Differential Contactor Separate mounting unit 4~6 MT-65a/2H5S MT-65a/3H5S MT-65a/3K5S 5~8 MT-65a/2H6.5S MT-65a/3H6.5S MT-65a/3K6.5S 6~9 MT-65a/2H7.5S MT-65a/3H7.5S MT-65a/3K7.5S 7~10 MT-65a/2H8.5S MT-65a/3H8.5S MT-65a/3K8.5S MT-65a/ 9~13 MT-65a/2H11S MT-65a/3H11S MT-65a/3K11S 12~18 MT-65a/2H15S MT-65a/3H15S MT-65a/3K15S 16~22 MT-65a/2H19S MT-65a/3H19S MT-65a/3K19S 18~25 MT-65a/2H21.5S MT-65a/3H21.5S MT-65a/3K21.5S 24~36 MT-65a/2H30S MT-65a/3H30S MT-65a/3K30S 28~40 MT-65a/2H34S MT-65a/3H34S MT-65a/3K34S 34~50 MT-65a/2H42S MT-65a/3H42S MT-65a/3K42S 45~65 MT-65a/2H55S MT-65a/3H55S MT-65a/3K55S MC-50a MC-65a UZ-63/S Setting range (A) Non-differential (3P-2 heater) Ordering type Non-differential (3P-3 heater) Differential Contactor Separate mounting unit 7~10 MT-100a/2H8.5S MT-100a/3H8.5S MT-100a/3K8.5S 9~13 MT-100a/2H11S MT-100a/3H11S MT-100a/3K11S 12~18 MT-100a/2H15S MT-100a/3H15S MT-100a/3K15S 16~22 MT-100a/2H19S MT-100a/3H19S MT-100a/3K19S 18~25 MT-100a/2H21.5S MT-100a/3H21.5S MT-100a/3K21.5S MT-100a/ 24~36 MT-100a/2H30S MT-100a/3H30S MT-100a/3K30S 28~40 MT-100a/2H34S MT-100a/3H34S MT-100a/3K34S 34~50 MT-100a/2H42S MT-100a/3H42S MT-100a/3K42S 45~65 MT-100a/2H55S MT-100a/3H55S MT-100a/3K55S 54~75 MT-100a/2H65S MT-100a/3H65S MT-100a/3K65S 63~85 MT-100a/2H74S MT-100a/3H74S MT-100a/3K74S 70~95 MT-100a/2H83S MT-100a/3H83S MT-100a/3K83S 80~100 MT-100a/2H90S MT-100a/3H90S MT-100a/3K90S MC-75a MC-85a MC-100a UZ-95/S 49

50 Overload relay ordering types Trip class 20 Direct mounting type ARC Setting range (A) Ordering type Differential Contactor Separate mounting unit 1~1.6 MT-18M/3D ~2.5 MT-18M/3D2.1 MT-18M/3K 2.5~4 MT-18M/3D3.3 4~6 MT-18M/3D5 5~8 MT-18M/3D6.5 6~9 MT-18M/3D7.5 7~10 MT-18M/3D8.5 9~13 MT-18M/3D11 MC-6a MC-9a MC-12a MC-18a AZ-12MH 12~18 MT-18M/3D15 Setting range (A) Ordering type Differential Contactor Separate mounting unit 1~1.6 MT-40a/3D ~2.5 MT-40a/3D ~4 MT-40a/3D3.3 4~6 MT-40a/3D5 MC-6a 5~8 MT-40a/3D6.5 MC-9a 6~9 MT-40a/3D7.5 7~10 MT-40a/3D8.5 MC-12a MC-18a UZ-32 9~13 MT-40a/3D11 MC-22a MT-40a/3D 12~18 MT-40a/3D15 16~22 MT-40a/3D19 MC-32a MC-40a 18~25 MT-40a/3D ~32 MT-40a/3D27 28~40 MT-40a/3D34 UZ-32(34A) 50

51 Trip class 20 Direct mounting type ARC Setting range (A) Ordering type Differential Contactor Separate mounting unit 4~6 MT-65a/3D5S 5~8 MT-65a/3D6.5S 6~9 MT-65a/3D7.5S 7~10 MT-65a/3D8.5S 9~13 MT-65a/3D11S MT-65a/3D S 12~18 MT-65a/3D15S 16~22 MT-65a/3D19S 18~25 MT-65a/3D21.5S 24~36 MT-65a/3D30S 28~40 MT-65a/3D34S 34~50 MT-65a/3D42S 45~65 MT-65a/3D55S MC-50a MC-65a UZ-63/S Setting range (A) Ordering type Differential Contactor Separate mounting unit 7~10 MT-100a/3D8.5S 9~13 MT-100a/3D11S 12~18 MT-100a/3DK15S 16~22 MT-100a/3D19S MT-100a/3D S 18~25 MT-100a/3D21.5S 24~36 MT-100a/3D30S 28~40 MT-100a/3D34S 34~50 MT-100a/3D42S 45~65 MT-100a/3D55S 54~75 MT-100a/3D65S 63~85 MT-100a/3D74S 70~95 MT-100a/3D83S 80~100 MT-100a/3D90S MC-75a MC-85a MC-100a UZ-95/S 51

52 Overload relay trip curves Class 10A, 18AF MT-18M/2H MT-18M/3H MT-18M/3K Cold starting Hot starting Minute Minute Tripping Time Tripping Time Second Second Multiple of current setting ln[a] Multiple of current setting ln[a] Class 20, 18AF MT-18M/3D Cold starting Hot starting Minute Minute Tripping Time Tripping Time Second Second Multiple of current setting ln[a] Multiple of current setting ln[a] 52

53 Class 10A, 40AF MT-40a/2H MT-40a/3H MT-40a/3K Cold starting Hot starting Minute Minute Tripping Time Tripping Time Second Second Multiple of current setting ln[a] Multiple of current setting ln[a] Class 20, 40AF MT-40a/3D Cold starting Hot starting Minute Minute Tripping Time Tripping Time Second Second Multiple of current setting ln[a] Multiple of current setting ln[a] 53

54 Overload relay trip curves Class 10A, 65AF MT-65a/2H MT-65a/3H MT-65a/3K Cold starting Hot starting Minute Minute Tripping Time Tripping Time Second Second Multiple of current setting ln[a] Multiple of current setting ln[a] Class 20, 65AF MT-65a/3D Cold starting Hot starting Minute Minute Tripping Time Tripping Time Second Second Multiple of current setting ln[a] Multiple of current setting ln[a] 54

55 Class 10A, 100AF MT-100a/2H MT-100a/3H MT-100a/3K Cold starting Hot starting Minute Minute Tripping Time Tripping Time Second Second Multiple of current setting ln[a] Multiple of current setting ln[a] Class 20, 100AF MT-100a/3D Cold starting Hot starting Minute Minute Tripping Time Tripping Time Second Second Multiple of current setting ln[a] Multiple of current setting ln[a] 55

56 Contactors (18AF/22AF) MC-6M~18M AC 1a or 1b [mm] MC-6M~18M DC 1a or 1b MC-6a~22a AC 1a1b MC-6a~22a DC 1a1b g 468g 327g 543g 56

57 Contactors (40AF) MC-25a~40a AC [mm] g MC-25a~40a DC g MC-25a~40a AC 35 2a2b g MC-25a~40a DC 35 2a2b g 57

58 Contactors (65AF) MC-50a~65a AC [mm] g MC-50a~65a DC g MC-50a~65a AC a2b g MC-50a~65a DC a2b g 58

59 Contactors (100AF) MC-75a~100a AC [mm] g MC-75a~100a DC g MC-75a~100a AC 55 2a2b g MC-75a~100a DC a2b g 59

60 Motor starters (18AF~40AF) MS-6M~18M [mm] MS-6a~22a M3.5 (Coil terminal) M4 (Main terminal) M3.5 (Aux terminal) 35 M4(Mounting hole) M3.5 (Coil terminal) M4/M5 (Main terminal) 45 93(86) 66(64) M4(Mounting hole) M3.5 (Aux terminal) M4/M5 (Aux terminal) g MS-32a~40a 7.5 M3.5 (Aux terminal) M4/M5 (Main terminal) g

61 Motor starters (65AF~100AF) MS-50a~65a M3.5 (Coil terminal) M6 (Main terminal) M4(Mounting hole) [mm] M3.5 (Aux terminal) M6 (Main terminal) M3.5 (Coil terminal) M8 (Main terminal) g MS-75a~100a M4(Mounting hole) M3.5 (Aux terminal) M8 (Main terminal) g 61

62 Reversing contactors and starters (18AF) MC-6MR~18MR AC [mm] g MC-6MR~18MR DC g MS-6MR~18MR AC

63 Reversing contactors and starters (22AF) MC-6aR~22aR AC [mm] g MC-6aR~22aR DC 1150g MS-6aR~22aR AC g 63

64 Reversing contactors and starters (40AF) MC-32aR~40aR AC [mm] g MC-32aR~40aR DC g MS-32aR~40aR AC 95-NC NO

65 Reversing contactors and starters (65AF) MC-50aR~65aR AC [mm] M4 41~47x92~100 M4 41~47x92~ g MC-50aR~65aR DC M4 41~47x92~100 M4 41~47x92~ g MS-50aR~65aR AC 95-NC NO

66 Reversing contactors and starters (100AF) MC-75aR~100aR AC [mm] M4 55~x130 M4 55~x g MC-75aR~100aR DC M4 55~x130 M4 55~x g MS-75aR~100aR AC NC NO

67 Overload relays MT-18M [mm] M3.5 (Aux terminal) M4/M5 (Main terminal) 95-NC NO-98 2T1 4T2 6T Main terminal M3.5 (Aux terminal) 95-NC NO-98 2T1 4T2 6T3 M6 (Main terminal) Main terminal g MT-40a Aux terminal 167g MT-65a Aux terminal 303g MT-100a 95-NC NO-98 M3.5 (Aux terminal) Aux terminal M8 (Main terminal) 2T1 4T2 6T Main terminal g 67

68 Overload relays (Separate mount) AZ-12MH Main terminal M4(Mounting hole) 35 [mm] M3.5 (Main terminal) M4(Mounting hole) 35 1L1 3L2 5L3 M4/M5(34A) (Main terminal) Main terminal M4(Mounting hole) 40 M6 (Main terminal) L1 3L2 5L Main terminal M4(Mounting hole) 1L1 3L2 5L3 M8 (Main terminal) Aux terminal 7 Main terminal g UZ-32 Main terminal Aux terminal g UZ-63 Main terminal Aux terminal 1340g UZ-95 Main terminal Aux terminal Main terminal 2300g 68

69 69 Contact arrangement Contactors A2 A1 V U R S 64 W T 63 MC-6M~18M 1a A2 A1 V U R S W T A2 A1 V U R S 44 W T MC-6a~22a A2 A1 V U R S 14 W T MC-32a~100a A2 A1 V U R S W T 1b 2a2b 1a1b

70 Contact arrangement Motor starters R/1/L1 S/3/L2 T/5/L3 A1 A2 A1 A /T1 4/T2 6/T R/1/L1 S/3/L2 T/5/L A1 A2 A1 A /T1 4/T2 6/T Reversing contactors A1 A2 R/1/L1 S/3/L2 T/5/L3 111NC 121NC R/1/L1 S/3/L2 T/5/L3 A1 A2 A1 A2 122NC 112NC A1 A2 U/2/T1 V/4/T2 W/6/T3 U/2/T1 V/4/T2 W/6/T3 Reversing starters A1 A2 R/1/L1 S/3/L2 T/5/L3 111NC 121NC R/1/L1 S/3/L2 T/5/L3 A1 A2 A1 A2 U/2/T1 V/4/T2 W/6/T3 112NC 122NC U/2/T1 V/4/T2 W/6/T3 A1 A /T1 4/T2 6/T

71

72 M e t a S o l u t i o n HEAD OFFICE LS Tower, Hokyeh 1dong, Dongan-gu, Anyang, Kyonggi-Do, , Korea Tel. (82-2) ~8 Fax. (82-2) Cheong-Ju Plant Cheong-Ju Plant #1, Song Jung Dong, Hung Duk Ku, Cheong Ju, , Korea /(01) (E) STAFF c LS Industrial Systems Co.,Ltd. All rights reserved.

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

22AF 40AF AF 150AF 225AF 400AF 800AF

22AF 40AF AF 150AF 225AF 400AF 800AF Contactors MC-Series UL508 E108780 Contactor 3 Pole Standards and Certifications UL508 IEC 60947-2 & IEC 60947-4-2 CSA C22.2 No.14 Features 8 Frame Sizes 1/2HP up to 600HP @ 480V AC Screw Terminals (Lug

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

Metasol MC 4pole. Contactor. Overview 108 Table of specifications 110 Dimension 114. Contents

Metasol MC 4pole. Contactor. Overview 108 Table of specifications 110 Dimension 114. Contents Metasol MC Contactor Overview 8 Table of specifications 1 Dimension 114 Contents Series completion More Safe, More Valuable Contactors & Overload Relays dvanced technology & Expert solution Offering economical

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

Quick selection table

Quick selection table Quick selection table Contactors... 100 to 800A Frame size 100A 15A 150A -pole Contactors s AC/DC common coil See page 46 for more details CGC-100 CGC-15 CGC-150 See page 46 for more details Ratings /

More information

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.

More information

Ktec Contactors and thermal overloads

Ktec Contactors and thermal overloads Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Switches Unlimited Phone: * Fax:

Switches Unlimited Phone: * Fax: For Info: sales@switchesunlimited.com www.switchesunlimited.com Phone: 800-1-0487 Fax: 718-67-6370 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

Overload Relays. Thermal (Bimetallic) style up to 800A. Overload relay structure

Overload Relays. Thermal (Bimetallic) style up to 800A. Overload relay structure Overload Relays Thermal (Bimetallic) style up to 800A CGT type overload relays are designed for the easy mounting directly to contactors or separately by using additional bases or brackets. Relays frame

More information

Page 2-4 Page 2-8. Page Page 2-13

Page 2-4 Page 2-8. Page Page 2-13 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings in AC3 440V duty: 6 to 630A IEC Power ratings in AC3 400V duty:. to 335kW UL/CSA ratings: 3 to 500HP

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

Overload Relays. Thermal (Bimetallic) style up to 800A. Overload relay structure

Overload Relays. Thermal (Bimetallic) style up to 800A. Overload relay structure Overload Relays Thermal (Bimetallic) style up to 800A CGT type overload relays are designed for the easy mounting directly to contactors or separately by using additional bases or brackets. Relays frame

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors... Three-pole versions up to 630A in IEC AC3 duty Four-pole versions up to 1600A in IEC AC1 duty Versions for power factor correction up to 100kvar at 400VAC Four-pole versions with NO+NC or 4NC main poles

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors 90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Modular contactor for installation into distribution boards

Modular contactor for installation into distribution boards Modular contactor for installation into distribution boards Description Modular contactors are used for installation in consumer units in dwellings, business premises, hotels, hospitals, shopping centres,

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

About us. Switchgear Factory, Mumbai

About us. Switchgear Factory, Mumbai About us Larsen & Toubro is a technologydriven USD 8.5 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering, Construction,

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information

Bimetal Overload Relays 3UA and 3UC

Bimetal Overload Relays 3UA and 3UC 32 Bimetal Overload Relays 3UA and 3UC The 3UA / 3UC thermal overload relays are suitable for customers from all industries, who want guaranteed optimum inverse time delayed protection of their electrical

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France Contact us ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F-69687 Chassieu cedex / France You can find the address of your local sales organisation on

More information

Thermal overload relay TF140DU and TF140DU-V1000

Thermal overload relay TF140DU and TF140DU-V1000 Data sheet Thermal overload relay TF140DU and TF140DU-V1000 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

Technical Information

Technical Information C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /

More information

SICOP. Bimetal Overload Relays Type 3UA5/6 & 3UC5/6. Introduction. Application

SICOP. Bimetal Overload Relays Type 3UA5/6 & 3UC5/6. Introduction. Application s SICOP Bimetal Overload Relays Type 3UA5/6 & 3UC5/6 Introduction The bimetal overload relays type 3UA5/6 & 3UC5/6 relays are indigenously manufactured and bring to the users a whole range of benefits,

More information

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line 2 Contactores Compactos CWC0 Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

Thermal overload relay TF65 and TF96

Thermal overload relay TF65 and TF96 Data sheet Thermal overload relay TF65 and TF96 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against overload and

More information

B Mini Contactor V Hz

B Mini Contactor V Hz ABB B7-30-10-80 Mini Contactor 220-240V 40-450Hz General Information Extended Product Type Product ID B7-30-10-80 GJL1311001R8100 EAN 4013614150197 Catalog Description Long Description B7-30-10-80 Mini

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

Manual Motor Starters

Manual Motor Starters Leader in Electrics & Automation Meta-MEC Manual Motor Starters Electric Equipment LG Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LG Meta-MEC

More information

Motor Protection Circuit Breakers 3VU13 and 3VU16

Motor Protection Circuit Breakers 3VU13 and 3VU16 Motor Protection Circuit Breakers 3VU13 and 3VU16 3VU13/3VU16 is suitable for use in fuseless motor feeders upto 11KW/22KW (25A/63A) respectively. 3VU motor protection circuit breakers are used for protection

More information

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated 11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF

More information

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control

More information

FMotor Circuit Controllers

FMotor Circuit Controllers Technical Information Motor Circuit Controller IEC Performance Data Catalog Number KTA7-25S...32S 0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A 20A 25A 29A 32A Rated Operational Current, I e [A]

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Motor Protection Circuit Breakers

Motor Protection Circuit Breakers Motor Protection Circuit Breakers About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions

More information

Cylindrical fuse-link

Cylindrical fuse-link Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

NR2 Thermal Overload Relay. 1. General. 2. Type Designation. 3. Features. Relays. EU Germany Ukrain Russia South Africa USA

NR2 Thermal Overload Relay. 1. General. 2. Type Designation. 3. Features. Relays. EU Germany Ukrain Russia South Africa USA R Relays C US LISTED EU Germany Ukrain Russia South Africa USA NR Thermal Overload Relay. General. Certificates: CE, VDE, Ukrain, PCT, RCC, UL;. Electric ratings: AC 50/0Hz, 90V, 0.A~30A;.3 Tripping class:

More information

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1

More information

Thermal Overload Relays

Thermal Overload Relays Data Sheet Thermal Overload Relays Ex9RD Series Ex9RD93 Ex9RD25 www.noarkusa.com NOARK Ex9RD Series Thermal overload relays are economic electromechanical protection devices for the main circuit. They

More information

MAGNETIC CONTACTOR & MOTOR STARTER

MAGNETIC CONTACTOR & MOTOR STARTER http://www.seec.com.tw http://circuit-breaker.seec.com.tw MAGNETIC CONTACTOR & MOTOR STARTER P Functionalities and characteristics of Magnetic Contactor Configuration Composite magnetic switch (abbreviated

More information

MAGNETIC CONTACTOR & MOTOR STARTER

MAGNETIC CONTACTOR & MOTOR STARTER http://www.seec.com.tw http://circuit-breaker.seec.com.tw MAGNETIC CONTACTOR & MOTOR STARTER P Functionalities and characteristics of Magnetic Contactor Configuration Composite magnetic switch (abbreviated

More information

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP Soft Starter Three-Phase Scroll Compressor Soft Starter Types RSBD Soft starting of 3-phase scroll compressors up to 95Amp Patented auto-adaptive algorithm for optimum inrush current reduction (No user

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1 Motor Contactor J7KN Range from 4 to 500 kw (AC 3, 380/415 V) AC and DC operated Integrated auxiliary contacts; integrated aux. contact of J7KN contactors up to 11kW suitable for electronic circuits Screw

More information

Bulletin 190-M Compact Starters. Selection Guide

Bulletin 190-M Compact Starters. Selection Guide Bulletin 190-M Selection Guide Bulletin 190-M Selection Guide 3 Bulletin 190-M Compact Design to 45mm Wide Common Adapter for Panel or DIN Rail Mounting Pre-Wired Assembly All Control Terminations Located

More information

KT4 Manual Motor Starter

KT4 Manual Motor Starter KT4 Manual Motor Starter Ideal for use as a manual starter The KT4 is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one

More information

Low Voltage Industrial Controls. CWB and RW27-2D. IEC Contactors and Thermal Overload Relays

Low Voltage Industrial Controls. CWB and RW27-2D. IEC Contactors and Thermal Overload Relays CWB and RW27-2D IEC Contactors and Thermal Overload Contactors Overload A-2-800-ASK4WEG www.weg.net/us Contactors CWB CWB Features A-4 Catalog Number Format A-7 Accessories Overview A-8 Part Number List

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays are the alternative to the thermal overload relays. An electronic overload relay offers reliable and fast protection

More information

Auxiliary contact blocks - with spring terminals Accessories

Auxiliary contact blocks - with spring terminals Accessories Auxiliary contact blocks - with spring terminals Accessories CA3-10S 1SBC101037F0014 Description The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits. CA3

More information

Bulletin 100-D IEC Contactors

Bulletin 100-D IEC Contactors Bulletin 100-D IEC Contactors Electronic and conventional coils AC & DC Integrated PLC interface Low power pick-up & hold-in Wide voltage ranges Complete range of accessories Environmentally friendly Compact

More information

Contactors & Overload relays

Contactors & Overload relays Contactors & Overload relays Metasol MC 3P 18 to 100 MC type Magnetic Contactors Frame size screws clamp terminals Number of poles Rated operational voltage, Ue Rated insulation voltage, Ui Rated frequency

More information

For Info: Phone: Fax:

For Info:   Phone: Fax: Page -2 TWO POLES IEC rated current Ith: 20A (AC1) IEC operational power: 1.3kW (AC3 230V) Ideal for domestic applications. Page -2 THREE AND FOUR POLES IEC rated current Ith: 25A, 40A and 63A (AC1) IEC

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

Ideal for use as a manual starter

Ideal for use as a manual starter Manual Motor Starter Ideal for use as a manual starter The is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one compact

More information

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660 Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,

More information

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Characteristics interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Stock Code: Stock - Normally stocked in distribution facility Price*: 4.20 USD Complementary Shape of pin Jul 8, 2015 Main Commercial

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

General technical data: CONTACTOR, AC-3, 4KW/400V, 2NO+2NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL REMOVABLE AUX. SWITCH. product brand name

General technical data: CONTACTOR, AC-3, 4KW/400V, 2NO+2NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL REMOVABLE AUX. SWITCH. product brand name Data sheet CONTACTOR, AC-3, 4KW/400V, 2NO+2NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL REMOVABLE AUX. SWITCH product brand name Product designation SIRIUS 3RT2 contactor General technical data: Size of contactor

More information

LR9 F OVERLOAD RELAYS

LR9 F OVERLOAD RELAYS Issued November 2009 DATA SHEET LR9 F OVERLOAD RELAYS Based on Schneider MKTED2050EN Catalogue General 6 Motor protection Operating conditions There are many possible causes of electric motor failure.

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Star Series Motor protection & control

Star Series Motor protection & control Contact us ABB Inc. Low Voltage Control Products 16250 W. Glendale Drive New Berlin, WI 53151 Phone: 888-385-1221 Fax: 800-726-41 USA Technical support & Customer Service: 888-385-1221, Option 4 7:30AM

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

FUJI Magnetic Contactors and Motor Starters

FUJI Magnetic Contactors and Motor Starters FUJI Magnetic Contactors and Motor Starters Technical Information AEH28a CONTENTS Chapter Contactors and Starters - International standards... 4-2 Ratings and specifications... 8-3 Performance and characteristics...

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

Product Selection 3-Pole Contactors

Product Selection 3-Pole Contactors - Contactors and January 0 Vol., Ref. No. [06] Product Selection -Pole Contactors When Ordering Specify Select required contactor by Catalog Number and replace the magnet coil alpha designation in the

More information

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals NSL..S 4-pole / 8-pole Contactor Relays - Spring DC Operated Description - 1-stack contactor relays: 4-pole, - 2-stack contactor relays: 8-pole, - Mechanically linked contact elements available, - Low

More information

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30 Contactors KNL KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30 Adaptable to various control requirements with ability of mounting from one to four additional auxiliary contacts. Versatile product capable

More information