1 Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH - A/90 V, 3-0 A/00 V CH -0 A/90 V (0 A/90 V am), 0-0 A/00 V 0 Hz CH 8 0 ka CH 0 ka CH - A/80 ka, 3-0 A/ ka CH -0 A/80 ka (0 A/80 ka am), 0-0 A/ ka gg, am ceramic With striker pin Material of contact parts CuZn8, gal.ag size e f d d x 3,8 7, x 8 3,8 7, r size a b max. c d min. r øc b b 8 x 3 3,±0,,7 8,±0, ±0, x 38 38,0±0,,,3±0,,±0, x,0+0,/- 3,8,3±0, 7, ± x 8 8,0+0,,,±0, ± a Time current characteristics I/t, gg CH8 t v (s) A A A 8A A AA 0A A Prearcing time (s)

2 Cut-off current characteristics CH8 I o (A) Maximum value of current (A) 3 I K I K 0 8 I n (A) 3 Melting energy characteristics I t CH8 I t (A s) 3 A 0A A A A 8A A A A A - 3 8

3 Time current characteristics I/t, gg CH I t (A t) A A A 8A A A A 0A A 3A Prearcing time (s) Cut-off current characteristics CH I o (A) Maximum value of current (A) 3 I K I K , I n (A) 3 9

4 I t (A s) Technical data Melting energy characteristics I t CH Time current characteristics I/t, gg CH t (s) 3A A A A 8A A A A 0A A 0A 0A Prearcing time (s)

5 I t (A s) Technical data Cut-off current characteristics CH I o (A) Maximum value of current (A) 3 I K I K I n (A) 3 Melting energy characteristics I t CH

6 Time current characteristics I/t, gg CH t v (s) Prearcing time (s) A 0A A 3A 0A 0A 3A 80A 0A - 3 Cut-off current characteristics CH I o (A) Maximum value of current (A) I K I K I n (A) 3

7 I t (A s) Technical data Melting energy characteristics I t CH Time current characteristics I/t, am CH,, , Prearcing time (s)

8 Fuse disconnectors for cylindrical fuse-links Technical data EFD EFD 8 EFD EFD CC EFD EFD EFD J30 Fuse type CH 8x3 CH x38 Class CC CH x CH x8 Class J, size J30 IEC IEC UL UL IEC UL IEC UL UL Versions Without indicator/led indicator/neon indicator Without indicator / LED indicator Number of poles p, p+n, p, 3p, 3p+N p, p, 3p p, p+n, p, 3p, 3p+N p, p, 3p p, p+n, p, 3p, 3p+N p, p, 3p Rated operational voltage Ue 00V a.c. 90V a.c. 00V 00V 90V a.c. 00V 90V a.c. 00V 00V Rated operational current Ie 0A 3A 30A 30A 0A 0A 0A 0A 30A Maximum rated current of fuselinks 90V A gg A gg A am 00V A gg 0A gg A am 00V 0A gg A am 0A gg 0A am 0A gg 3A gg 0A am 0A am Rated frequency 0Hz 0Hz 0Hz 0Hz 0Hz 0Hz 0Hz 0Hz 0Hz Rated short-time withstand current Icw 0A 300A/s 00A/s 0A/s Conventional free air thermal current Ith 0A 0A Rated conditional short-circuit current 0kA 0kA/00V 0kA 00kA gg: ka/00v (0A gg) am: 0kA/00V (0A am) 0kA gg: ka/00v (0A gg) am: 0kA/00V (0A am) Rated insulation voltage Ui 00V 90V 90V 90V Rated imp. withstand voltage Uimp 8kV 8kV 8kV 8kV Overvoltage category (according to Table H. in IEC 097- and according to IEC 0099-) III III III III Max power dissipation of the fuse-link (W) gg:,w am: 0,9W LED indicator operating range 0V-90V a.c. NEON indicator operating range 0V-70V a.c. gg: 3W am:,w 0V-90V a.c. 0V-70V a.c. 0-00V 3W 0-00V Utilization category AC- AC- Do not operate under load Operational performance (cycles with current) gg: W am: 3W 0V-90V a.c. AC- at 90V/0A 0-00V Do not operate under load gg: 9,W am: 7W 0V-90V a.c. AC- at 90V/0A Operational performance (cycles without current) Humidity 90% at 0 C 90% at 0 C 90% at 0 C Operating ambient temperature - C to +0 C - C to +0 C - C to +0 C Store ambient temperature - C to + C - C to + C - C to + C Degree of protection (IEC 09) IP 0 IP 0 IP 0 IP 0 Terminal capacity -mm -mm AWG 8-8 solid&stranded Cu only,-3mm rigid or flexible AWG - solid&stranded Cu only -0mm rigid or flexible 0kA 0-00V 00kA W 0-00V Do not operate under load AWG - solid&stranded Cu only Screw PZ M PZ M PZ M PZ M PZ M PZ M PZ M PZ M PZ M Torque Nm Nm Nm; 7,7 lb-in,-3nm Nm; 7,7 3Nm 3Nm;, lb-in lb-in Mounting on EN 07 rail 3mm rail Sealing posibility ON and OFF Standards - fuse links IEC/EN 09- IEC/EN 09- IEC/EN 09- UL 8- IEC/EN 09- IEC/EN 09- IEC/EN 09- IEC/EN 09- IEC/EN 09- UL 8-8 IEC/EN 09- Standards - fuse disconnectors/ fuse holders IEC 097- IEC UL 8- UL 8- UL 8E CSA C. No. IEC 097- IEC UL 8- UL 8E IEC 097- IEC UL 8- UL 8E CSA C. No. CSA C. No. UL 8- UL 8-8 UL 8E CSA C. No. CSA C. No. Test reports CCA/C CCA/C UL UL CCA/C UL CCA/C UL UL Certificates UR C US UL C US UR C US UR C US UL C US

9 Fuse disconnector EFD Fuse disconnector EFD 8, EFD type dimension EFD 8, p 7, EFD 8, p+n 3 EFD 8, p 3 EFD 8, 3p, EFD 8, 3p+N 70 Fuse disconnector EFD CC type dimension EFD CC p 7, EFD CC p 3 EFD CC 3p, Version with adapter Fuse disconnector EFD type dimension EFD p 7 EFD p+n EFD p EFD 3p 8 EFD 3p+N 8 Fuse disconnector EFD & EFD J30 type dimension EFD, J30 p 3, EFD p+n 7, EFD, J30 p 7, EFD, J30 3p,8 EFD 3p+N, PS VLC PS VLC Auxiliary switch EFD PS EFD PS EFD

10 Technical data PCF PCF 8 PCF PCF CC Fuse type CH 8x3 CH x38 Class CC IEC IEC UL UL Versions Without indicator / LED indicator Number of poles p, p+n, p, 3p, 3p+N p, p, 3p Rated operational voltage Ue 00V a.c. 90V a.c. 00V 00V Rated operational current Ie 0A 3A 30A 30A Maximum rated current of fuselinks 90V A gg 00V A gg, A am 00V 0A gg, A am 3A gg Rated frequency 0Hz 0Hz 0Hz 0Hz Rated short-time withstand current Icw 0A 300A Rated conditional short-circuit current 0kA 0kA 00kA 00kA Rated insulation voltage Ui 00V 90V Rated imp. withstand voltage Uimp kv kv Overvoltage category III III Max power dissipation of the fuse-link (W) gg:,w / am: 0,9W gg: 3W / am:,w LED indicator operating range 0V-90V a.c. 0V-90V a.c. 0V-00V 0V-00V Utilization category AC- AC- Do not operate under load Operational performance (cycles with current) Operational performance (cycles without current) Humidity 90% at 0 C Operating ambient temperature - C to +0 C Store ambient temperature - C to + C Degree of protection (IEC 09) IP 0 IP 0 Terminal capacity 0,-mm, Double connection 0- stranded, Cu only 0- solid&stranded, Cu only Screw PZ M PZ M PZ M PZ M Torque,Nm,Nm,Nm,Nm Mounting on EN 07 rail 3mm rail Sealing posibility ON and OFF Standards - fuse links IEC/EN 09- UL 8-, IEC/EN 09- Standards - fuse disconnectors/fuse holders IEC 097-, IEC UL 8- UL 8-, UL 8- Test reports Int. CCA/C UL Int Certificates UR C US Fuse disconnector PCF 3,8,, 83,3 Fuse disconnector PCF 8, PCF, PCF CC type dimension PCF 8,, CC p 7,8 PCF 8, p+n 7,8 PCF 8,, CC p 3, PCF 8,, CC 3p 3, PCF 8, 3p+N 3,,8 Auxiliary switch PS PCF

Cylindrical fuse-link

Cylindrical fuse-link ylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity haracteristics Body material 00 V A, 500 V A, 90 V A H 8-5 A/00 V H 0,5- A/500 V, 0-3 A/00 V H -5

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

Special Purpose Fuses

Special Purpose Fuses Special Purpose Fuses Fuses for DC voltage applications www.eti.si ETI Elektroelement d.d. Obrezija 5, SI - 111 Izlake Slovenija Tel. + 38 03 5 57 570 Faks + 38 03 5 7 077 eti@eti.si NH DC 80 V - Telecom

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

K50H004UP cam changeover switch - 4-pole A - screw mounting

K50H004UP cam changeover switch - 4-pole A - screw mounting Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

K30H001YP cam star-delta switch - 3-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

Modular contactor for installation into distribution boards

Modular contactor for installation into distribution boards Modular contactor for installation into distribution boards Description Modular contactors are used for installation in consumer units in dwellings, business premises, hotels, hospitals, shopping centres,

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information

MS25, MST25, MS20, MST20

MS25, MST25, MS20, MST20 Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440

More information

Technical data. Busbar support 3 7, 5 6, 8 ETIBUSBAR 1 0, 5 BBS-60/4

Technical data. Busbar support 3 7, 5 6, 8 ETIBUSBAR 1 0, 5 BBS-60/4 Busbar support 20 30 BBS-/1 BBS-/3 57 52 29 29 1 5 3 0 1 5 10 2 0 5 3 7, 5 6 0 6 0 6 0 6, 8 12 1 0, 5 7 5 1 2 5 2 4 0 20 30 18 BBS-/4 563 98,5 10 29 93,5 5 29 18 75 180 10,5 6,8 30 30 25 20 52,5 12 BBS-/3-16

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC. Page -2 Page -2 AC FUSE HOLDERS Version without indicator: 1P, 1P+N, 2P, 3P, 3P+N Version with indicator: 1P For fuses x38, 14x51 and 22x58mm IEC class gg or am. IEC rated current: 32A, 50A, 0A IEC rated

More information

Fuse holders and fuses

Fuse holders and fuses Modular size for 10x38, 14x51 and 22x58mm fuses Finger safe - IEC IP20 degree of protection against accidental contact with live parts and with sealable cover for operators safety Version with status indicator

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1

More information

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX 70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX SWITCH DISCONNECTORS IN METAL BOX ATEX SWITCH DISCONNECTORS IN METAL BOX The switch disconnectors in plastic boxes, which are available in control or emergency

More information

INDUSTRIAL CYLINDRICAL FUSE LINKS

INDUSTRIAL CYLINDRICAL FUSE LINKS gg Cylindrical gg class for use as general protection against overloads and short circuits, intended as protection of cables, power lines and equipment. Made of ceramic tube with high withstand to internal

More information

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking MainswitchSurfacemounting Partno. P1-25/I2/SVB-SW Articleno. 207294 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

FUSIBLE DISCONNECT SWITCHES (UL98) GM SERIES

FUSIBLE DISCONNECT SWITCHES (UL98) GM SERIES FUSIBLE DISCNECT SWITCHES (UL98) GM SERIES Three-pole disconnect switches with fuse holder (UL98) GMF...030 C12 GMFJ 100 C03 GMFJ 400 C03 GMFJ 800 C03 Add-on blocks GMX10 10 GMX3... GMX8 00 GMX8 01 GMX5...

More information

For Info: Phone: Fax:

For Info:   Phone: Fax: Page -2 TWO POLES IEC rated current Ith: 20A (AC1) IEC operational power: 1.3kW (AC3 230V) Ideal for domestic applications. Page -2 THREE AND FOUR POLES IEC rated current Ith: 25A, 40A and 63A (AC1) IEC

More information

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control

More information

NEW EFD fuse disconnector

NEW EFD fuse disconnector NEW EFD fuse disconnector More space for finger to open fuse carrier Advantages of cylindrical fuse disconnector EFD ompliance with IE 60947-1, IE 60947-3, UL 4248-1, UL 4248-4, UL 4248-8, UL 486E and

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors MOTOR STARTERS SM Basic function Switching and protection of motors up to A Protection against short-circuit and protection against overload The device responds to phase failure The device is provided

More information

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101428D0201 28/03/11 -.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays are the alternative to the thermal overload relays. An electronic overload relay offers reliable and fast protection

More information

fuses fuse holders CYLINDRICAL

fuses fuse holders CYLINDRICAL fuses fuse holders 02 gg FUSES 04 am FUSES FUSES 09 PMC COMPACT 09 -CC FOR CC CLASS FUSE-LINKS 11 PMB PLUG CONNECTION 11 CLIP CONTACT FOR φ10 FUSE-LINKS 10 PMF 11 BAC OPEN FUSE BASES 06 gg FUSES FUSES

More information

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC Product data sheet Characteristics LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 -

More information

Safety rope switches with reset for emergency stop

Safety rope switches with reset for emergency stop Safety rope switches with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+ FP FD FL FC 22 33 34 LED signalling light CONDUIT ENTRIES For other available

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

LK Position Switches TECHNICAL DATASHEET.

LK Position Switches TECHNICAL DATASHEET. LK Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 60529 contact blocks available 46 actuators available Versions with stainless steel external parts Versions

More information

Low voltage NH knife-blade fuse-links

Low voltage NH knife-blade fuse-links Low voltage NH knife-blade fuse-links NV KOMBI advantages ETI is introducing a new generation of low-voltage fuse-links from size NV00C up to NV3 with new, dual indication of fuse-link operation, called

More information

INNOZED D0 fuse-bases with touch protection

INNOZED D0 fuse-bases with touch protection INNOZED D0 fusebases with touch protection INNOZED D0 fusebases with touch protection FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC D0 & D FUSE BASES FEATURES & BENEFITS INNOZED is a fuse base for D0 fuselinks,

More information

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 3.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 3.ST8 comprises NH fuse switch disconnectors for 630A. They are designed for bottom

More information

UltraSafe US22 Modular fuse-holders

UltraSafe US22 Modular fuse-holders UltraSafe US22 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive UltraSafe range of Mersen fuse-holders. are finger-safe under IEC standards

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0 MainswitchSurfacemounting Partno. T0-2-1/I1/SVB-SW Articleno. 207148 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking MainswitchRearmounting Partno. T0-2-1/V/SVB-SW Articleno. 045992 Front IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC Product datasheet Characteristics LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 -

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS SUMMARY OF MODELS Type 10 14 22 OPT22/OPT20 OPVF10 Rated operating current I e / Rated current I n 32 A / - 63 A / - 125 A / - 63 A / - - / 30 A Rated operating voltage U e / Rated voltage U n AC 690 V

More information

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole MULTIBLOC 000.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS The production programme of MULTIBLOC 000.ST8 comprises NH fuse switch disconnectors for 100A. They are designed

More information

Modulostar CMS10 Modular fuse-holders

Modulostar CMS10 Modular fuse-holders Modulostar CMS10 FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC CYLINDRICAL FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC

More information

FUSE BASES NH FUSE BASES 690V 160A 160A

FUSE BASES NH FUSE BASES 690V 160A 160A fuse bases NH NH 14 690V NH 16 ACCESSORIES FOR NH 18 CR 690V NH 20 SECTIONABLE NEUTRAL NH BASES 21 BS FUSE SWITCH DISCONNECTORS 690V NH NH Fuse bases for NH fuse links. For mounting on DIN/EN rail or

More information

Motorized switch-disconnectors OTM 40 to 125 Amperes

Motorized switch-disconnectors OTM 40 to 125 Amperes Motorized switch-disconnectors OTM to 125 mperes With the new range of motorized-switch disconnectors, BB offers now a full range from to 2500 mperes. Thanks to the design, OTM...125 are a good solution

More information

DBL distribution blocks 3x1 pole

DBL distribution blocks 3x1 pole TECHNICAL DATASHEET 1SNC166019D0201 - CATALOGUE PAGE 1SNC166020S0201 DBL distribution blocks 3x1 pole 84.6 3.33" 25 0.98" 32.5 1.28" 28.2 1.11" 23.5 0.93" 14.7 0.58" 36.3 1.43" 75 2.95" 62 2.44" 50.7 2"

More information

FUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS

FUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS 1 2 06 PML 10/14x85 1500V FUSE HOLDERS 08 CLIP CONTACT FOR φ10 FUSE LINKS 05 PMX & 14x51 FUSE HOLDERS 02 gpv & 14x51 600 &/1100 FUSE LINKS 03 gpv 1200 & 1500V FUSE LINKS 04 gpv NH1, NH2 & NH3 FUSE LINKS

More information

Electronic overload relays EF205 and EF370

Electronic overload relays EF205 and EF370 Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 1.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 1.RST8 comprises NH fuse switch disconnectors for 250A. Products are designed in triple

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

CATALOG. EasyLine XLP Fuse Switch Disconnector poles

CATALOG. EasyLine XLP Fuse Switch Disconnector poles CATALOG EasyLine XLP Fuse Switch Disconnector 1-2-3-4 poles 2 E A S Y L I N E X L P F U S E S W I TC H D I S C O N N E C TO R 1-2 - 3-4 P O L E S Contents 004 005 Introduction EasyLine XLP 006 007 Introduction

More information

Safety rope switch with reset for emergency stop

Safety rope switch with reset for emergency stop Safety rope switch with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+,, FP FD FL FC 22 33 34,, CONDUIT ENTRIES Threaded conduit entries (standard) With

More information

Mini contactors B6, BC6 with 3 pole

Mini contactors B6, BC6 with 3 pole Data sheet Mini contactors B6, BC6 with 3 pole Mini contactors from ABB are used for remotely ling motors and other loads wherever space is at a premium. These devices feature hum free coils, shallow depth,

More information

Modulostar US10 Modular fuse-holders

Modulostar US10 Modular fuse-holders Modulostar US10 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC standards

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1 MainswitchSurfacemounting Partno. T0-2-8900/I1/SVB Articleno. 207151 CatalogNo. CT02-8900-I1CRQ Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC Product datasheet Characteristics LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 -

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

GREEN PROTECT PROTECTION OF PV SYSTEMS. Green protect - DC POWER NEEDS CONTROL

GREEN PROTECT PROTECTION OF PV SYSTEMS. Green protect - DC POWER NEEDS CONTROL GREEN PROTECT DC - distribution and protection components Cylindrical fuse-links Fuse holders for cylindrical fuse-links Accessories for cylindrical fuses NH fuse -links NH fuse bases NH fuse disconnectors

More information

Auxiliary contact blocks - with spring terminals Accessories

Auxiliary contact blocks - with spring terminals Accessories Auxiliary contact blocks - with spring terminals Accessories CA3-10S 1SBC101037F0014 Description The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits. CA3

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED

More information

fuse-links & fuse holders PHOTOVOLTAIC

fuse-links & fuse holders PHOTOVOLTAIC fuse-links & fuse holders 04 gpv FOR APPLICATIONS 04 gpv FOR APPLICATIONS 05 gpv & FOR APPLICATIONS 06 PMF FUSE HOLDERS FOR APPLICATIONS 07 ST & FUSE BASES FOR APPLICATIONS FUSE HOLDERS & BASES gpv 10x38

More information

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30 Contactors KNL KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30 Adaptable to various control requirements with ability of mounting from one to four additional auxiliary contacts. Versatile product capable

More information

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch

More information

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 2.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 2.RST8 comprises NH fuse switch disconnectors for 400A. Products are designed in triple

More information

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals NSL..S 4-pole / 8-pole Contactor Relays - Spring DC Operated Description - 1-stack contactor relays: 4-pole, - 2-stack contactor relays: 8-pole, - Mechanically linked contact elements available, - Low

More information

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660 Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,

More information

FL series position switches

FL series position switches FL series position switches Selection diagram 0 08 0 9 0 0 0 Ball Ø. External rubber Ball Ø 8 mm, mm, stainless Glass fibre rod gasket stainless steel steel Adjustable lever Adjustable safety lever Bistable

More information

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition Product datasheet Characteristics LC1F400E7 Complementary [Uimp] rated impulse withstand voltage Overvoltage category [Ith] conventional free air thermal current Main Range Product name Product or component

More information

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description

More information

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole MULTIBLOC 1.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 1.ST8 comprises NH fuse switch disconnectors for 250A. They are designed for bottom

More information

MULTIVERT 1000A Main Incomer, 690VAC

MULTIVERT 1000A Main Incomer, 690VAC IEC FUSE SWITCH DISCONNECTORS NH VERTICAL FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS MULTIVERT NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed

More information

Thermal overload relay TF140DU and TF140DU-V1000

Thermal overload relay TF140DU and TF140DU-V1000 Data sheet Thermal overload relay TF140DU and TF140DU-V1000 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against

More information

ZS4-SF1 Screw Clamp Terminal Block

ZS4-SF1 Screw Clamp Terminal Block Technical Datasheet 1SNK 161 011 D0201 ZS4-SF1 Screw Clamp Terminal Block Fuse Catalogue Page 1SNK 161 011 S0201 4 mm² 10 AWG 8 mm 0.315 in Spacing Features and Benefits 90 90 180 59.7 2.35" - Protect

More information

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 2.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 2.ST8 comprises NH fuse switch disconnectors for 400A. They are designed for bottom

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Typ 415 NH-Sicherungsleisten, BTVA/BTVA-P, NH 1/2/3, 250/400/630 A, 185mm Sammelshienenabstand

Typ 415 NH-Sicherungsleisten, BTVA/BTVA-P, NH 1/2/3, 250/400/630 A, 185mm Sammelshienenabstand LV-SWITCHING DEVICES / NH-SCHALTGERÄTE 1 Vertical 415 design fuse rails TRIVER / NH-Sicherungsleisten TRIVER Range / Produktpalette Type 415 fuse rails BTVA/BTVA-P, NH 1/2/3, 2/400/, mm busbars spacing

More information

DC-Switch Disconnectors for Photovoltaic acc. to IEC

DC-Switch Disconnectors for Photovoltaic acc. to IEC DC-Switch Disconnectors for Photovoltaic acc. to IEC 60364-7-712 Ratings DC-Switch Disconnectors Rated current DC21B at U e I th open 4 poles in series Type A A V LS16 16 16 LS25 25 25 LS32 32 32 LS40

More information

Short-circuit current limiter S800-SCL-SR

Short-circuit current limiter S800-SCL-SR Short-circuit current limiter S800-SCL-SR 2 ABB Short-circuit current limiter S800-SCL-SR Self-resetting current limiting module S800-SCL-SR is ABB s innovative self-resetting current limiting module which

More information

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons Characteristics pendant control station XAC-A - 8 pushbuttons Complementary Control station colour Connections - terminals Mechanical durability Cable entry Contact code designation [Ithe] conventional

More information

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3 Introducing the New WEG Series. The was developed according to IEC 60947-3 & UL508. The compact, reliable design of the allows the operator to safely disconnect power and isolate the circuit within the

More information

Safety switches with separate actuator

Safety switches with separate actuator Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 ACTUATORS VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 FR FX FK FW 5 6 7 11 1 14 NC NC slow action slow

More information

Fuse switch-disconnectors

Fuse switch-disconnectors Fuse switch-disconnector FH000 is intended for fuse-links with blade contacts size 000. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Characteristics interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Stock Code: Stock - Normally stocked in distribution facility Price*: 4.20 USD Complementary Shape of pin Jul 8, 2015 Main Commercial

More information

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons Characteristics pendant control station XAC-A - 8 pushbuttons Main Range of product Product or component type Device short name Complementary Control station type Enclosure material Electrical circuit

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information