1 Index Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3 phase... Contactors, non-reversing, B6 & B7, 3 phase...3 Control relays, K622 - K60, AC/DC operated...10 Control relays, features...1 Cross-reference, old catalog numbers to new...2 Description...1 General features...1 Interface contactors, features...1 Interface relays, KC631 - KC60, DC operated...11 Mechanically interlocked contactors, features...1 Overload relays, features...1 Starters, non-reversing, B6 & B7, single phase...9 Starters, non-reversing, B7, 3 phase...8 Thermal overload relays, T7DU...7 Accessories Auxiliary contact blocks...12 Identification labels...12 Plunger...12 Protective cover...13 Reversing connection link...13 Soldering connection...12 Surge suppressors...13 Technical data Auxiliary contacts...15 Contactors, B Contactors, B Control relays, K D.C. Power circuit switching...1 Electrical durability curves...1 Endurance curves...17 Magnetic coils...15 Overload relays...19 Pole configurations...18 Switching of light fittings...17 Dimensions Auxiliary contact blocks...21 Contactors, mechanically interlocked...21 Control relays...21 Mini contactors...20 Overload relays...20 Low Voltage Products & Systems.A

2 Notes.B Low Voltage Products & Systems

3 Contactors Overload relays Starters Control relays Description General features Wiring terminations available include plugon connectors, wire pins for PC board mounting and solder connections Low power consumption coils Touch safe design: All screw connection terminals are protected against accidental touch Slotted Pozidriv terminal screws Screwdriver guide holes Self-lifting cable clamps Panel or DIN rail mounting Terminals supplied in the open position Electrically noiseless operation Snap-on accessories UL Listed, file # E39231 CSA approved, file #LR15332 IEC, VDE & most international standards Contactors B6 and BC6 miniature contactors can be used for small motors up to 1 HP, 60V B7 and BC7 miniature contactors can be used for small motors up to 5 HP, 60V Applications include use in machines, electrical appliances, building automation systems, heating systems, overhead door applications, etc. B6 and B7 miniature contactors are designed to be directly connected to a PLC transistor output Interface contactors Interface mini-contactors are normally used to establish an isolation between the electronic part and the process in large automation systems Mechanically interlocked contactors Compact, mechanically interlocked contactors are available Can be used for reversing applications Control relays AC & DC operated Overload relays 1 setting ranges from 0.11 to 10.5 amps Manual or automatic reset Phase failure compensation Ambient temperature compensation Stop and test button functions UL Listed, file #E19922 CSA approved, file # LR98336 Low Voltage Products & Systems.1

4 Controls.2 Low Voltage Products & Systems Cross-reference B6C- B B6C-*01 B B6CP- B B7C- B B7C- 01 B B7CP- B BC6C- BC BC6C- 01 BC BC7C- BC BC7C- 01 BC B6CFP- B F B6CFP- 01 B F B6CPFP- B F B7CFP- B F B7CFP- 01 B F B7CPFP- B F BC6CFP- BC F BC6CFP- 01 BC F BC7CFP- BC F BC7CFP- 01 BC F B6CSP- B P B6CSP- 01 B P B6CPSP- B P B7CSP- B P B7CSP- 01 B P B7CPSP- B P BC6CSP- BC P BC6CSP- 01 BC P BC7CSP- BC P BC7CSP- 01 BC P VB6M- VB VB6M- 01 VB VB7M- VB VB7M- 01 VB VB6CM- VB6C VB6CM- 01 VB6C VB7CM- VB7C VB7CM- 01 VB7C VB6MFP- VB F VB6MFP- 01 VB F VB7MFP- VB F VB7MFP- 01 VB F VBC6MFP- VBC F VBC6MFP- 01 VBC F VB7CMFP- VB7C F VB7CMFP- 01 VB7C F VB6MSP- VB P VB6MSP- 01 VB P VB7MSP- VB P VB7MSP- 01 VB P VBC6MSP- VBC P VBC6MSP- 01 VBC P VB7CMSP- VB7C P VB7CMSP- 01 VB7C P BC6-1. BC BC BC BC7-1. BC BC BC BC6-2. BC BC BC BC7-2. BC BC BC BC6FP-1. BC F1. BC6FP BC F1. BC7FP-1. BC F1. BC7FP BC F1. BC6FP-2. BC F2. BC6FP BC F2. BC7FP-2. BC F2. BC7FP BC F2. BC6SP-1. BC P1. BC6SP BC P1. BC7SP-1. BC P1. BC7SP BC P1. BC6SP-2. BC P2. BC6SP BC P2. BC7SP-2. BC P2. BC7SP BC P2. B6SC-1.7 B6S B6SC B6S B7SC-1.7 B7S B7SC B7S B6SC-2.8 B6S B6SC B6S B7SC-2.8 B7S B7SC B7S K60- K60E- K631- K631Z- K622- K622Z- KC60- K6-0E-F KC631- K6-31Z-F KC622- K6-22Z-F K60FP- K6-0E-F K631FP- K6-31Z-F K622FP- K6-22Z-F KC60FP- K6-0E-F KC631FP- K6-31Z-F KC622FP- K6-22Z-F K60SP- K6-0E-P K631SP- K6-31Z-P K622SP- K6-22Z-P KC60SP- K6-0E-P KC631SP- K6-31Z-P KC622SP- K6-22Z-P Old catalog New catalog Old catalog New catalog Old catalog New catalog

5 Contactors B6 & B7, non-reversing 3 Phase B B B F Non-reversing with screw connections General Maximum 3 Phase motor horsepower Single phase Number of AC1 AC3 208V 230V 60V 600V 120V 230V poles AC operated 3 1 N.O. B N.C. B $ 51 B N.O. B N.C. B B DC operated / N.O. BC N.C. BC N.O. BC N.C. BC Non-reversing with flat pin connections General Maximum 3 Phase motor horsepower Single phase Number of AC1 AC3 208V 230V 60V 600V 120V 230V poles AC operated 3 1 N.O. B F 1 N.C. B F $ 51 B F 3 1 N.O. B F 1 N.C. B F 72 B F DC operated / N.O. BC F 3 1 N.C. BC F N.O. BC F 3 1 N.C. BC F 80 B P Non-reversing with soldering pin connections General Maximum 3 Phase motor horsepower Single phase Number of AC1 AC3 208V 230V 60V 600V 120V 230V poles AC operated 3 1 N.O. B P 1 N.C. B P $ 51 B P 3 1 N.O. B P 1 N.C. B P 72 B P DC operated / N.O. BC P 3 1 N.C. BC P N.O. BC P 3 1 N.C. BC P 78 Coil voltage selection Coil voltage suffix. Refer to Coil Voltage Selection Chart and substitute the desired coil voltage suffix for the. Coil voltage selection chart Volts / / /20 380/15 AC (0-50 Hz) DC Low Voltage Products & Systems Discount schedule MB [OK].3

6 Controls Contactors B6 & B7, mechanically interlocked 3 Phase Mechanically interlocked with screw connections VB General Maximum 3 Phase motor horsepower Single phase Number of AC1 AC3 208V 230V 60V 600V 120V 230V poles AC operated DC operated 1 N.O. VB N.C. VB $ 10 1 N.O. VB N.C. VB N.O. VBC N.C. VBC N.O. VBC N.C. VBC Mechanically interlocked with flat pin connections VB General Maximum 3 Phase motor horsepower Single phase Number of AC1 AC3 208V 230V 60V 600V 120V 230V poles AC operated DC operated 1 N.O. VB F 1 N.C. VB F $ 10 1 N.O. VB F 1 N.C. VB F 13 1 N.O. VBC F 1 N.C. VBC F N.O. VBC F 1 N.C. VBC F 156 Mechanically interlocked with soldering pin connections General Maximum 3 Phase motor horsepower Single phase Number of AC1 AC3 208V 230V 60V 600V 120V 230V poles AC operated DC operated 1 N.O. VB P 1 N.C. VB P $ 10 1 N.O. VB P 1 N.C. VB P 13 1 N.O. VBC P 1 N.C. VBC P N.O. VBC P 1 N.C. VBC P 156 Coil voltage selection Coil voltage suffix. Refer to Coil Voltage Selection Chart and substitute the desired coil voltage suffix for the. Coil voltage selection chart Volts / / /20 380/15 AC (0-50 Hz) DC Discount schedule MB [OK] Low Voltage Products & Systems

7 Contactors 1 B6 & B7, Interface 3 Phase Non-reversing with screw connections BC General Maximum 3 Phase motor horsepower Single phase Number of AC1 AC3 208V 230V 60V 600V 120V 230V poles DC operated 2VDC (1.W low power consumption) DC operated 17 32VDC (2.W low power consumption) 1 N.O. BC N.C. BC $ 57 1 N.O. BC N.C. BC N.O. BC N.C. BC N.O. BC N.C. BC Non-reversing with flat pin connections BC General Maximum 3 Phase motor horsepower Single phase Number of AC1 AC3 208V 230V 60V 600V 120V 230V poles DC operated 2VDC (1.W low power consumption) DC operated 17 32VDC (2.W low power consumption) 1 N.O. BC F1. 1 N.C. BC F1. $ 57 1 N.O. BC F1. 1 N.C. BC F N.O. BC F2. 1 N.C. BC F N.O. BC F N.C. BC F2. Non-reversing with soldering pin connections General Maximum 3 Phase motor horsepower Single phase Number of AC1 AC3 208V 230V 60V 600V 120V 230V poles DC operated 2VDC (1.W low power consumption) DC operated 17 32VDC (2.W low power consumption) 1 N.O. BC P1. $ 57 1 N.C. BC P1. 1 N.O. BC P N.C. BC P1. 1 N.O. BC P2. 1 N.C. BC P2. 1 N.O. BC P2. 1 N.C. BC P Interface contactors cannot utilize auxiliary contacts. Low Voltage Products & Systems Discount schedule MB [OK].5

8 Controls Contactors B6S & B7S for connection to PLCs 1 3 Phase Non-reversing with screw connections B6S General Maximum 3 Phase motor horsepower Single phase Number of AC1 AC3 208V 230V 60V 600V 120V 230V poles DC operated 2VDC (1.W low power consumption) DC operated 17 32VDC (2.W low power consumption) 1 N.O. B6S N.C. B6S $ 65 1 N.O. B7S N.C. B7S N.O. B6S N.C. B6S N.O. B7S N.C. B7S B7S Oscillograms typical operation without internal surge suppression 2 V V µs Switching off of interface contactors BC6, BC7, coil voltage 2 VDC. 2V 0 with internal surge suppression 0 switch off Switching off of B6S, B7S coil voltage 2VDC which provides electrically noiseless operation 1 Contactors for connection to PLCs cannot utilize auxiliary contacts..6 Discount schedule MB [OK] Low Voltage Products & Systems

9 Thermal overload relays T7DU T7DU Thermal overload relay for contactors B6,B7, BC6, BC7, B6S, B7S, VB6(7), VBC6(7), VB6A(7A), VBC6A(/7A) Setting range Catalog List Amps number price T7DU T7DU T7DU T7DU T7DU T7DU1.6 $ T7DU T7DU T7DU T7DU T7DU12.0 Loading capacity of auxiliary switches Type N.C. T7DU N.O Rated operating voltage U e /V IEC / UL508 V 500 / / 300 Thermal current A 6 6 Rated operating current I e at AC /20 V A at AC /15 V A at AC V A at DC V A Pilot duty rating General use AC A300 A300 DC P300 P300 20V 1.5A 1.5A 600V 0.6A 0.6A Thermal overload relay T7DU Setting range Short circuit protection (fuses, circuit breakers) Joule losses per phase Coordination Type 2 (IEC) Coordination Type 1(IEC) 600V, 5kA Resistance at upper per phase current gl/gg gl/gg Fuse MCCB setting A A A A W W A A A A A A A A A A A Electronic overload relays See pages 2.19 to Low Voltage Products & Systems Discount schedule MB [OK].7

10 Controls Starters 1 B6 & B7, non-reversing 3 Phase Non-Reversing, 3 phase Screw connections only General Maximum 3 Phase motor horsepower Single phase Number of AC1 AC3 208V 230V 60V 600V 120V 230V poles AC operated 1 N.O. B6S- $ N.C. B6S N.O. B7S N.C. B7S- 01 DC operated 1 N.O. BC6S N.C. BC6S N.O. BC7S N.C. BC7S- 01 Coil voltage suffix. Refer to Coil Voltage Selection chart and substitute the desired coil voltage suffix for the. Overload relay suffix. Refer to the Overload Relay Selection chart and substitute the desired starter suffix code for the. B6S- Reversing, 3 phase Screw connections only General Maximum 3 Phase motor horsepower Single phase Number of AC1 AC3 208V 230V 60V 600V 120V 230V poles AC operated DC operated 1 N.O. B6SR- 1 N.C. B6SR N.O. B7SR- 1 N.C. B7SR N.O. BC6SR- 1 N.C. BC6SR N.O. BC7SR- 1 N.C. BC7SR- 01 Coil voltage suffix. Refer to Coil Voltage Selection chart and substitute the desired coil voltage suffix for the. Overload relay suffix. Refer to the Overload Relay Selection chart and substitute the desired starter suffix code for the. $ Coil voltage selection Volts / / /20 380/15 AC (0-50 Hz) DC Overload relay selection T7DU Thermal overload Catalog number Current setting range Starter range code T7DU A T7DU B T7DU C T7DU D T7DU E T7DU F T7DU G T7DU H T7DU J T7DU K T7DU L E16DU Electronic overload Catalog number Current setting range Current tripping class Starter range code E16DU A1 E16DU B1 E16DU C1 E16DU D1 E16DU E1 E16DU A2 E16DU B2 E16DU C2 E16DU D2 E16DU E2 E16DU A3 E16DU B3 E16DU C3 E16DU D3 E16DU E3 List price adder $ 33 1 For enclosed miniature starters, please consult factory for catalog number and pricing..8 Discount schedule MB [OK] Low Voltage Products & Systems

11 Starters 1 B6 & B7, Non-reversing Single phase Non-Reversing, Single phase Screw connections only General Maximum Single phase Number of AC1 AC3 120V 230V poles AC operated / DC operated / N.O. B6SS- 1 N.C. B6SS N.O. B7SS- 1 N.C. B7SS N.O. BC6SS- 1 N.C. BC6SS N.O. BC7SS- 1 N.C. BC7SS- 01 Coil voltage suffix. Refer to Coil Voltage Selection chart and substitute the desired coil voltage suffix for the. Overload relay suffix. Refer to the Overload Relay Selection chart and substitute the desired starter suffix code for the. $ Coil voltage selection Volts / / /20 380/15 AC (0-50 Hz) DC Overload relay selection T7DU Thermal overload Catalog number Current setting range Starter range code T7DU A T7DU B T7DU C T7DU D T7DU E T7DU F T7DU G T7DU H T7DU J T7DU K T7DU L 1 For enclosed miniature starters, please consult factory for catalog number and pricing. Low Voltage Products & Systems Discount schedule MB [OK].9

12 Controls Control relays K622 - K60 AC & DC operated Control relays with screw connections AC Operated DC Operated Contact configuration Thermal Catalog List N.O. N.C. current A number price 0 K6-0E K6-31Z- $ K6-22Z- 0 KC6-0E KC6-31Z KC6-22Z- K6-0E-8 Control relays with flat pin connections AC Operated DC Operated Contact configuration Thermal Catalog List N.O. N.C. current A number price 0 K6-0E-F K6-31Z-F $ K6-22Z-F 0 KC6-0E-F KC6-31Z-F KC6-22Z-F Control relays with soldering pin connections KC6-31Z-2. AC Operated DC Operated Contact configuration Thermal Catalog List N.O. N.C. current A number price 0 K6-0E-P K6-31Z-P $ K6-22Z-P 0 KC6-0E-P KC6-31Z-P KC6-22Z-P Coil voltage selection Coil voltage suffix. Refer to Coil Voltage Selection Chart and substitute the desired coil voltage suffix for the. Coil voltage selection chart Volts / / /20 380/15 AC (0-50 Hz) DC Discount schedule MB [OK] Low Voltage Products & Systems

13 Interface relays 1 KC6-31Z & KC6-0E DC operated Interface relays with screw connections Contact configuration Thermal Catalog List N.O. N.C. current A number price DC Operated 2VDC (1.W low power consumption) 0 KC6-0E KC6-31Z-1. DC Operated 17 32VDC (2.W low power consumption) 0 KC6-0E KC6-31Z-2. $ Interface relays with flat pin connections KC6-0E-1. Contact configuration Thermal Catalog List N.O. N.C. current A number price DC Operated 2VDC (1.W low power consumption) 0 KC6-0E-F KC6-31Z-F1. DC Operated 17 32VDC (2.W low power consumption) 0 KC6-0E-F KC6-31Z-F2. $ KC6-31Z-2. Interface relays with soldering pin connections Contact configuration Thermal Catalog List N.O. N.C. current A number price DC Operated 2VDC (1.W low power consumption) 0 KC6-0E-P KC6-31Z-P1. DC Operated 17 32VDC (2.W low power consumption) 0 KC6-0E-P KC6-31Z-P2. $ Interface relays cannot utilize auxiliary contacts. Low Voltage Products & Systems Discount schedule MB [OK].11

14 Controls Accessories for B6 & B7 contactors CA6-11K CA6-11E-F CA6-11K-P CAF6-11M Auxiliary contact blocks Soldering connection Plunger Identification labels Item Contact Catalog List description configuration number 1 price Side mounted auxiliary contact blocks, 1 N.O. & 1 N.C. Screw connection type KC6 & K6 relay 1 N.O. & 1 N.C. CA6-11K B6 or BC6; B7 or BC7 pole contactor 1 N.O. & 1 N.C. CA6-11E B6 or BC6; B7 or BC7 3 pole contactor, 1 N.O. 1 N.O. & 1 N.C. CA6-11M B6 or BC6; B7 or BC7 3 pole contactor, 1 N.C. 1 N.O. & 1 N.C. CA6-11N Flat pin connection type KC6 & K6 relay 1 N.O. & 1 N.C. CA6-11K-F B6 or BC6; B7 or BC7 pole contactor 1 N.O. & 1 N.C. CA6-11E-F B6 or BC6; B7 or BC7 3 pole contactor, 1 N.O. 1 N.O. & 1 N.C. CA6-11M-F B6 or BC6; B7 or BC7 3 pole contactor, 1 N.C. 1 N.O. & 1 N.C. CA6-11N-F Soldering pin connection type KC6 & K6 relay 1 N.O. & 1 N.C. CA6-11K-P B6 or BC6; B7 or BC7 pole contactor 1 N.O. & 1 N.C. CA6-11E-P B6 or BC6; B7 or BC7 3 pole contactor, 1 N.O. 1 N.O. & 1 N.C. CA6-11M-P B6 or BC6; B7 or BC7 3 pole contactor, 1 N.C. 1 N.O. & 1 N.C. CA6-11N-P Front mounted auxiliary contact blocks, 1 N.O. & 1 N.C. Screw connection type KC6 & K6 relay 1 N.O. & 1 N.C. CAF6-11K KC6 & K6 relay 2 N.O. & 0 N.C. CAF6-20K KC6 & K6 relay 0 N.O. & 2 N.C. CAF6-02K B6 or BC6; B7 or BC7 pole contactor, VB(C)... 1 N.O. & 1 N.C. CAF6-11E B6 or BC6; B7 or BC7 pole contactor, VB(C)... 2 N.O. & 0 N.C. CAF6-20E B6 or BC6; B7 or BC7 pole contactor, VB(C)... 0 N.O. & 2 N.C. CAF6-02E B6 or BC6; B7 or BC7 3 pole contactor, 1 N.O., VB(C)... 1 N.O. & 1 N.C. CAF6-11M B6 or BC6; B7 or BC7 3 pole contactor, 1 N.O., VB(C)... 2 N.O. & 0 N.C. CAF6-20M B6 or BC6; B7 or BC7 3 pole contactor, 1 N.O., VB(C)... 0 N.O. & 2 N.C. CAF6-02M B6 or BC6; B7 or BC7 3 pole contactor, 1 N.C., VB(C)... 1 N.O. & 1 N.C. CAF6-11N B6 or BC6; B7 or BC7 3 pole contactor, 1 N.C., VB(C)... 2 N.O. & 0 N.C. CAF6-20N B6 or BC6; B7 or BC7 3 pole contactor, 1 N.C., VB(C)... 0 N.O. & 2 N.C. CAF6-02N $ 15 Item Catalog List description number price For mini contactors, B, BC, K, & KC LB6 $ 15 For 2 pole auxiliary contacts LB6-CA 8 Item Catalog List description number price For manual operation BN6 $ 15 Item Catalog List description number price 50 clip-on label holders, 60 non-adhesive labels 50 transparent covers, 75 self adhesive labels BA5-50 $ 15 BA 50 1 contactors and control relays can use either front or side mounted auxiliary blocks but not both..12 Discount schedule MB [OK] Low Voltage Products & Systems

15 Accessories for B6 & B7 contactors Surge suppressors Item Voltage Catalog List description number price 2 60V RV-BC6/60 Varistor type surge suppressor for DC operated coils V RV-BC6/250 $ V RV-BC6/380 RV-BC6/... Protective cover Item Catalog List description number price For contactors B, BC, K, & KC6 with screw connection LT6-B $ 15 Reversing connection link Item Catalog List description number price For compact interlocking contactors with screw connection BSM6-30 $ 12 LT6-B Line side (L) Load side (T) BSM6-30 Low Voltage Products & Systems Discount schedule MB [OK].13

16 Controls IEC Technical data D.C. Power circuit switching Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms V A V A V A V A V A V A V A V A V A V A V A V A V A V A V A Electrical durability curves for DC-1, DC-3 and DC-5 The curves below take into account the time constant L/R for each utilization category and show the electrical durability of the contactors during DC-1, DC-3 and DC-5 use for 3 poles connected in series. If one single pole is used, the corresponding breaking capacity (W) is reduced to 1/3 and for 2 poles connected in series it is reduced to 2/3. A = DC-1 B = DC-3 C = DC-5 3 poles in series 3 poles in series 3 poles in series Millions of operating cycles Breaking power (W).1 Low Voltage Products & Systems

17 IEC Technical data B6 Contactors & K6 control relays Auxiliary contacts & magnetic coils Millions of operations Millions of operations Endurance curves B 6, BC 6, B 6S Endurance curves K6, KC6, CA6, CAF AC Rated operating current [A] AC1 Endurance curves B 6, BC 6, B 6S Switch off current [A] AC B6 contactors Rated insulating voltage V i 500 Permissible ambient temperature Contactor without relay C Contactor with relay C Storage temperature C Climatic resistance acc. to DIN alternating climate proof acc. to UTE C cycles, version 1 Mounting position optional Mechanical endurance 10 million operations Max. switching frequency AC 1 cyc./h 300 AC 2/AC 3 cyc./h 600 Rated operating voltage V e V AC 12 to 500 Rated operating current I e /AC 1, AC 3 AC 1/I e A AC 2, AC 3 Rated operating power 55 C 0 C I e A P kw 220/20 V /0 V / V Switching times B6 BC6 K6 KC6 Closing delay NO ms 20 to to 26 Opening delay NO ms 16 to 20 to 6 16 to 20 to 6 Closing delay NC ms 16 to 20 to 6 16 to 20 to 6 Opening delay NC ms 1 to 18 1 to 18 K6 Control relays & auxiliary contacts Rated operating voltage V e VDC 12 to 20 VAC 12 to 500 Conventional rated thermal current I th A 6 Rated operating current I e / AC 15 at V e 220/20 V A 380/0 V A V A 2 Rated operating current I e /DC 13 at V e 2 V A V A V A /20 V A 0. Magnetic coils Millions of operations AC 15 Coil voltage range x U c Basic contactors closing /holding B6 / K6, VB6 AC VA 3.5 BC6 / KC 6, VBC6 DC W 3.5 Interface contactors BC6 / KC6-1. DC 2 V W 1. BC6 / KC6-2. DC V W Switch off current (A) Mini contactor for connection to PLC's cold warm I ma P W I ma P W B6 S-1.7 DC V W B6 S-2.8 DC V W Low Voltage Products & Systems.15

18 2T1 T2 6T3 1NO Controls IEC Technical data B7 contactors Magnetic coils Millions of operations Millions of operations Endurance curves B 7, BC 7, B 7S Rated operating current AC3 AC Switch off current [A] AC B7 contactors Rated insulating voltage V i 500 Permissible ambient temperature Contactor without relay C Contactor with relay C Storage temperature C Climatic resistance acc. to DIN alternating climate proof acc. to UTE C cycles, version 1 Mounting position Mechanical endurance B1 A C1 1L1 3L2 5L3 13NO 0 C2 A1 A2 A B2 10 million operations optional Max. switching frequency AC 1 cyc./h 300 AC 2/AC 3 cyc./h 600 Rated operating voltage V e VAC 12 to 500 Rated operating current I e /AC 1, AC 3 AC 1/I e A AC 2, AC 3 Rated operating power 55 C 0 C I e A P kw 220/20 V / /0 V / V Switching times B7 BC7 Closing delay ms 20 to 26 NO Opening delay ms 16 to 20 to 6 Closing delay ms 16 to 20 to 6 NC Opening delay ms 1 to 18 Shock resistance B6, B7 standard mounting position Magnetic Coils Coil voltage range 1/2 sinusoidal shock, 10 ms: no change in contact position shock directions A B1 B2 C1 C2 contactor switched on 20 g 20 g 20 g 20 g 20 g contactor switched off 10 g 20 g 20 g 20 g 20 g x U c Rated power of magnetic coils Basic contactors closing /holding B7 / VB7 AC VA 3.5 BC7 / VBC7 DC W 3.5 Interface contactors BC7-1. DC + 2 V W 1. BC7-2. DC V W 2. Mini contactor for connection to PLC's cold warm I (ma) P (W) I (ma) P (W) B7 S-1.7 DC + 2 V B7 S-2.8 DC V Low Voltage Products & Systems

19 IEC Technical data Switching of light fittings The following tables show the number of lamps which can be connected per phase at 230 V/ 60 Hz. Note the following: a) Increased current consumption for 1.1 times the rated voltage is considered. b) Failure of about 5% of the lamps is considered since not ignited lamps additionally charge the contactor with their preheating current. c) This data only apply to connection of the lamps at main pole terminals Lamp type Lamp data Permissible number of lamps per phase (230 V, 60 Hz) for contactor type Watt cm A B6, B7, BC6, BC7 Incandescent lamps Fluorescent lamps uncompensated Fluorescent 2 x x x 26 lamp lamps in 2 x x x 20 pairs two-lamp circuit 2 x x x 16 2 x x x 12 2 x x x 5 2 x x x 5 Metal halogen lamps uncompensated Low pressure sodium vapor lamps uncompensated High pressure mercury vapor lamps uncompensated High pressure mercury vapor lamps uncompensated Endurance curves for DC1, DC3, DC5 The following shows endurance curves for DC1, DC3 and DC5 for 3 poles in series. If only one current path is used, the corresponding breaking capacity is multiplied by 0.33, for two current paths by Varying time constants L/R (ms) have been considered. Millions of operations Switch off power (W) A B C A = 3 poles in series DC 1 B = 3 poles in series DC 3 C = 3 poles in series DC 5 Low Voltage Products & Systems.17

20 Controls IEC Technical data Pole configurations contactors A A A A2 B6(7) BC6(7) A2 B6(7) BC6(7) A2 B6(7) BC6(7) mechanically interlocked contactors A A1 A A1 A VB6(7) VBC6(7) A2 A VB6(7) VBC6(7) A2 control relays A A A A2 K6-0 E... KC6-0 E A2 K6-31 Z... KC6-31 Z A2 K6-22 Z... KC6-22 Z... Side mounted auxiliary contact blocks Front mounted auxiliary contact blocks CA6-11E CA6-11E-F CA6-11E-P B6(7)-0-00 B6(7)-0-00-F B6(7)-0-00-P BC6(7) CAF B6(7)-0-00 B6(7)-0-00-F B6(7)-0-00-P BC6(7) = CAF6-11E 2 = CAF6-20E 3 = CAF6-02E CA6-11M CA6-11M-F CA6-11M-P B6(7) B6(7) F B6(7) P BC6(7) CAF B6(7) B6(7) F B6(7) P BC6(7) = CAF6-11M 2 = CAF6-20M 3 = CAF6-02M CA6-11N CA6-11N-F CA6-11N-P B6(7) B6(7) F B6(7) P BC6(7) CAF B6(7) B6(7) F B6(7) P BC6(7) = CAF6-11N 2 = CAF6-20N 3 = CAF6-02N CA6-11K CA6-11K-F CA6-11K-P.18 Low Voltage Products & Systems E 31Z 22Z K6... K6... F K6...P KC E 31Z 22Z K6... K6... F K6...P KC = CAF6-11K 2 = CAF6-20K 3 = CAF6-02K NOTE: Only side mounted type or front mounted type auxiliary contact blocks can be used at one time. Auxililiary contact blocks must not be mounted on Interface contactors, Interface control relays or contactors for connection to PLCs. Two CAF 6 front mounted auxiliary contact blocks can installed on the mechanically interlocked contactors VB(C)6(7).

21 IEC technical data Overload relays Type T7DU Standards: (major international and European standards) IEC 97--1, UL 508 EN Approvals, certificates UL, CSA Rated insulation voltage U i acc. to IEC 158-1, IEC V 690V acc. to IEC / UL 508Ui/V660V / 600V Impulse withstand voltage UimpkV6 acc. to IEC Permissible ambient temperature for storage C -0 to 70 with compensated operation C open C -25 to + 50 C enclosed C -25 to + 0 C Climatic resistance according to IEC , IEC Mounting position ±30 from vertical position not horizontally, not upside down Side by side mounting distance, 5mm Resistance to shock Shock duration ms 10 *Critical shock direction A1, A2 multiple of g 10 Resistance to vibrations (±1 mm, 50 Hz) multiple of g Mounting on contactor Hooking underneath the contactor, screwing on its main terminal Terminal types and connecting capacity of main conductors (on motor side) Screw terminals (screw size) with self-disengaging clamping piece M3.5 with terminal block with busbar or cable lugs connection cross sections single-core or stranded Awg/mm2 2 x 18 1 / 2 x flexible with connector sleeve mm2 2 x Terminals and auxiliary conductors Screw terminals (screw size) with self-disengaging clamping piece M3.5 connection cross sections single-core or stranded Awg/mm2 2 x 18 1 / 2 x flexible with connector sleeve mm2 2 x Protection degree to IEC 97-1/EN All terminals are safe from finger-touch and touch by the back of the hand in accordance with VDE 0106, Part 100 Power pole technical data Number of poles 3 Setting ranges see order codes Tripping class acc. to IEC 97--1/EN A Frequency limit Hz 0 00 Switching frequency up to 15 ops./h or 60 ops./h with 0% on load factor without early tripping if starting current not higher than 6 x In and starting time not longer than 1s. Approvals UL CSA EZU PTB GL LRS USA Canada Czech. Republic Germany Germany Great Britain Legend: Standard design approved: identification plates bear the approval marks if it is mandatory Submitted for approval Low Voltage Products & Systems.19

22 Controls Approximate dimensions Mini contactors & overload relays Inches [Millimeters] Mini contactors AC & DC Operated B6, BC6, B7, BC Mini contactor with overload relay B6, B7 & T7DU E16DU with B/BC6, B/BC7 B7/ T7DU.20 Low Voltage Products & Systems

23 Inches [Millimeters] Approximate dimensions Mechanically interlocked contactors, control relays Auxiliary contact blocks Mechanically interlocked AC & DC Operated VB6M, VBC6M, VB7M, VBC7M Mini control relays AC & DC Operated K6, KC Mini contactor with side mounted auxiliary contact block B6, B7 & CA Mini contactor with front mounted auxiliary contact block B6, B7 & CA CAF6 A1 A Low Voltage Products & Systems.21

24 Controls Notes.22 Low Voltage Products & Systems

Mini Contactors. Technical Catalogue. Type B6, B7 ABB

Mini Contactors. Technical Catalogue. Type B6, B7 ABB Technical Catalogue Mini Contactors Type B6, B7 ABB ABB Mini contactors B6/4 kw; B7/5.5 kw Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T7DU Contents Mini contactors

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1

More information

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

Thermal overload relays Type TA Class 10

Thermal overload relays Type TA Class 10 Thermal overload relays Type TA Class Thermal Overload relays Description Available for starter construction with A Line contactors and separate panel mounting Designed for close couple mounting Separate

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated 11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF

More information

Technical data for manual motor starters Type MS325

Technical data for manual motor starters Type MS325 for manual mor starters Type MS325 General data Rated voltage 600 V Rated current 25 A (14 setting ranges, 0.1 25A) Rated frequency 50-60 Hz Electrical and mechanical life endurance 100,000 operations

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

smissline Description

smissline Description Modular power distribution bus system Description The power distribution bus system provides a versatile and flexible means of distributing power to a wide variety of electrical devices. Ideal for group

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

B Mini Contactor V Hz

B Mini Contactor V Hz ABB B7-30-10-80 Mini Contactor 220-240V 40-450Hz General Information Extended Product Type Product ID B7-30-10-80 GJL1311001R8100 EAN 4013614150197 Catalog Description Long Description B7-30-10-80 Mini

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line 2 Contactores Compactos CWC0 Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

BC Mini Contactor VDC

BC Mini Contactor VDC ABB Mini Contactor 110-125VDC General Information Extended Product Type Product ID GJL1213001R0014 EAN 4013614052859 Catalog Description Long Description Mini Contactor 110-125VDC The BC6-30-01 mini contactor

More information

Application Mini Contactors for Motors and Resistive Loads

Application Mini Contactors for Motors and Resistive Loads Delivery program Contactor, 4p, 4kW/400V/AC3 Part no. DILEM4-G(24VDC) Catalog No. 012701 Eaton Catalog No. XTMF9A00TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads

More information

Mini Contactors CI 4-

Mini Contactors CI 4- Data sheet Mini Contactors CI 4- Introduction CI 4 minicontactors cover the power range 1.5 to 5.9 kw and are available for a.c. and d.c. coil voltages. Characteristic of the minicontactors is that they

More information

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1 Motor Contactor J7KN Range from 4 to 500 kw (AC 3, 380/415 V) AC and DC operated Integrated auxiliary contacts; integrated aux. contact of J7KN contactors up to 11kW suitable for electronic circuits Screw

More information

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories Thermal Overload Relay J7TKN ) Thermal Overload Relay Direct and separate mounting Single phasing sensivity according to IEC 60947-4-1 Finger proof (BGV A2) Accessories Set for single mounting Approved

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting. DATASHEET - ZB12-2,4 Delivery program Overload relay, 1.6-2.4 A, 1N/O+1N/C Part no. ZB12-2,4 Catalog No. 278437 Eaton Catalog No. XTOB2P4BC1 EL-Nummer 0004131832 (Norway) Product range Overload relay ZB

More information

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102 Overloadrelay,10-16A,1N/O+1N/C Partno. ZB12-16 Articleno. 290168 CatalogNo. XTOB016BC1 Deliveryprogramme Product range Overload relay ZB up to 150 A Frame size ZB12 Phase-failure sensitivity IEC/EN 60947,

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD. DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals NSL..S 4-pole / 8-pole Contactor Relays - Spring DC Operated Description - 1-stack contactor relays: 4-pole, - 2-stack contactor relays: 8-pole, - Mechanically linked contact elements available, - Low

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

W Datasheet: DIN Rail Contactors, series AMPARO

W Datasheet: DIN Rail Contactors, series AMPARO W Datasheet: DIN Rail Contactors, series AMPARO W SCHRACK-INFO For suiting of fans, pumps, heating & lighting Noise reducing design Low vibration on DIN-rail 230V 50/60Hz oder 24V 50/60 Hz coil DIN-Rail

More information

Controls. CONTACTORS CWB Line (up to 40A)

Controls. CONTACTORS CWB Line (up to 40A) Controls CONTACTORS CWB Line (up to 40A) 0800 367 934 Contactors CWB Line (up to 40A) CONTACTORS CWB Line (up to 40A) Summary New WEG CWB Contactors 4 The Technology Within 6 Energy Savings 7 Easy Panel

More information

Accessories for Contactors and Contactor Relays

Accessories for Contactors and Contactor Relays 4/0 Accessories for Contactors and Contactor Relays Contents Accessories for A... Series and BC... Series Contactors and for Contactor Relays Auxiliary Contact Blocks - Front Mounting... 4/2 Auxiliary

More information

CI-TI Contactors and Motor Starters Type CI 6-50

CI-TI Contactors and Motor Starters Type CI 6-50 Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components

More information

Contactor Types CI 61-98

Contactor Types CI 61-98 MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories

More information

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Positively guided contacts Screw fixing and snap fitting (35 mm DIN rail) Rated

More information

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101 IEC CONTACTORS Description: RT01 Contactors Are Available With Cage Clamps On The Main Terminal Connections As Well As The Auxiliary Terminal Connections. RT02, RT0 and RT04 Contactors Are Available With

More information

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Safety Relay Unit Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Two-pole slim models that are only 22.5 mm wide, three-pole models that are only 68 mm wide,

More information

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer DATASHEET - ZB65-65 Delivery program Overload relay, 50-65A, 1N/O+1N/C Part no. ZB65-65 Catalog No. 278460 Eaton Catalog No. XTOB065DC1 EL-Nummer 0004131855 (Norway) Product range Overload relay ZB up

More information

3RT14 Contactors with 3 Main Contacts

3RT14 Contactors with 3 Main Contacts 3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Contactor Size 3RT14 46 Mechanical endurance Oper. 10 million Electrical endurance Oper. 0.5 million C-1 utilization category at I e

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

Overloadrelay,10-16A,1N/O+1N/C. Articleno

Overloadrelay,10-16A,1N/O+1N/C. Articleno Overloadrelay,10-16A,1N/O+1N/C Partno. ZB32-16 Articleno. 278452 CatalogNo. XTOB016CC1 Deliveryprogramme Product range Overload relay ZB up to 150 A Product range Accessories Accessories Overload relays

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Bulletin 193-T1 Bimetallic Overload Relays

Bulletin 193-T1 Bimetallic Overload Relays Bulletin 193T1 Bimetallic Overload Relays Overload protection trip class 10 / 10A Phase loss protection Ambient temperature compensation Auxiliary contacts (1 N.O. and 1 N.C.) Manual/automatic reset mode

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

Industrial contactors CTX-1

Industrial contactors CTX-1 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 Industrial contactors /04/05/10/12/14/15/20/22/24/25/30/32/34/35/40/42/44/45 CONTENTS PAGE 1. Use... 1 2. Range... 1 3. Electrical

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440

More information

Thermal Overload Relays - WEG RW Series, 2 Pole

Thermal Overload Relays - WEG RW Series, 2 Pole International (5) 4-07 The RW Class Thermal Overload Relays, with their extended operational service lives, are designed for use with the CWC miniature and CWM standard contactors. These relays can be

More information

Modular contactor for installation into distribution boards

Modular contactor for installation into distribution boards Modular contactor for installation into distribution boards Description Modular contactors are used for installation in consumer units in dwellings, business premises, hotels, hospitals, shopping centres,

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors... Three-pole versions up to 630A in IEC AC3 duty Four-pole versions up to 1600A in IEC AC1 duty Versions for power factor correction up to 100kvar at 400VAC Four-pole versions with NO+NC or 4NC main poles

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

Page 2-4 Page 2-8. Page Page 2-13

Page 2-4 Page 2-8. Page Page 2-13 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings in AC3 440V duty: 6 to 630A IEC Power ratings in AC3 400V duty:. to 335kW UL/CSA ratings: 3 to 500HP

More information

Star Series Motor protection & control

Star Series Motor protection & control Contact us ABB Inc. Low Voltage Control Products 16250 W. Glendale Drive New Berlin, WI 53151 Phone: 888-385-1221 Fax: 800-726-41 USA Technical support & Customer Service: 888-385-1221, Option 4 7:30AM

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5- MKING MODERN LIVING POSSIBLE Technical brochure Minicontactors CI 5- www.danfoss.com 2 IC.PD.C10.F3.02-520B4167 Danfoss /S, C-SMC, mr, 07-2010 Contents Page Minicontactor CI 5- Introduction...............................................................................4

More information

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h No Filter 81.6 % Auto 9.1 m3/h 250.0 m3/h Auto 99.7 m3/h 100.0 m3/h Auto 91.3 m3/h 92.0 m3/h Auto 40.0 m3/h 7. MW Auto 50.7 m3/h 50.0 m3/h 7.2 % Auto.6 % 45.0 % ABB NF Contactor Relays Overview...3 Ordering

More information

Technical Information

Technical Information C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /

More information

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V 804 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96-60-468 A07NN A Man Motor Protector Eaton Corp Catalog Number A07NN Manufacturer Eaton Corp Description Manual Motor Starter, Motor Protector;

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for

More information

Ktec Contactors and thermal overloads

Ktec Contactors and thermal overloads Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America

More information

Mini contactors B6, BC6 with 3 pole

Mini contactors B6, BC6 with 3 pole Data sheet Mini contactors B6, BC6 with 3 pole Mini contactors from ABB are used for remotely ling motors and other loads wherever space is at a premium. These devices feature hum free coils, shallow depth,

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2. Deliveryprogramme Contactorrelay,3N/O+1N/C,DCcurrent Partno. DILER-31-G-C(110VDC) Articleno. 231831 CatalogNo. XTRMC10A31E0 Product range DILER Mini-contactors Application Contactor relays Description

More information

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2. Deliveryprogram Contactorrelay,2N/O+2N/C,DCcurrent Partno. DILER-22-G(220VDC) Articleno. 010091 CatalogNo. XTRM10A22BD Product range DILER Mini-contactors Application Contactor relays Description with

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

and Refrigeration Institute). CNX Special Purpose Contactors

and Refrigeration Institute). CNX Special Purpose Contactors Series C7 Special Use Contactors Contactors designed and labeled for specific industrial applications Special Use Contactors Hydraulic elevator duty contactors HVC rated contactors Lighting contactors

More information

Switches Unlimited Phone: * Fax:

Switches Unlimited Phone: * Fax: For Info: sales@switchesunlimited.com www.switchesunlimited.com Phone: 800-1-0487 Fax: 718-67-6370 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings

More information

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical) MODULAR DEVICES The range of two, three and four pole isolator switches are of a modular design and fit on DIN 50022 rail. Terminal capacity is 25mm 2. Isolator Switches Rating Poles Modules Reference

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175. SIRIUS 3RT0 3-Pole with AC Coil 3RT0* through 3RT04* 4-point AC coil can be wired on top, bottom, or diagonally. Direct mount 3RU or 3RB0 solid state overload relays to create starters. Snap-on auxiliary

More information

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30 Contactors KNL KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30 Adaptable to various control requirements with ability of mounting from one to four additional auxiliary contacts. Versatile product capable

More information

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions Installation Contactors Z-SCH These switching devices have been designed and rated particularly for modular installation in modular distribution boxes for electrical installation or cabinets with device

More information

Application Mini Contactors for Motors and Resistive Loads

Application Mini Contactors for Motors and Resistive Loads Deliveryprogramme Contactor,3p+1N/O,4kW/400V/AC3 Partno. DILEM-10-G(24VDC) Articleno. 010213 CatalogNo. XTMC9A10TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads Subrange

More information

Manual Motor Starter MS 116. Technical Catalogue

Manual Motor Starter MS 116. Technical Catalogue Manual Motor Starter MS 116 Technical Catalogue The task: Economic fuseless motor protection Know-how in safe-keeping ABB is a renowned manufacturer of electrical motors. But apart from the hardware in

More information