CI-TI Contactors and motor starters Types CI 61 - CI 98
|
|
- Godwin Henry
- 6 years ago
- Views:
Transcription
1 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include a wide selection of auxiliary contacts, mechanical interlocks and RC elements. for mounting on the side or top are available. The auxiliary contacts have force-actuated contacts and can form part of safety switching. Danfoss DCS (az) 08.0 IC.PD.C00.F6.0
2 Data sheet CI-TI Contactors and motor starters, s CI 6 - CI 98 Ordering Contactors CI 6, CI 7, CI 86, CI 98 U e 0 40 V Main circuit - load I th ) U e (-) I V e Open I the ) (-) Encl. Main contacts (make) [kw] [kw] [A] [A] [A] Number Number Add-on options Code no. ) CI H06 CI H06 CI H06 CI H040 ) Coil voltage / frequency or Suffix no. (see table below) must be added to the Danfoss code no. ) The thermal current I th gives the maximum load at 40 C, which corresponds to installing the contactor in air (open). ) The thermal current I the gives the maximum load at 60 C, which corresponds to installing the contactor in an enclosure. Coil voltages and coils for CI 6, CI 7, CI 86, C 98 Coil voltage ) - (sufix no.) Contactor Code no. 4 V 50/60 Hz () 0 V, 50/60 Hz () 0 0 V, 50/60 Hz () V, 50/60 Hz (9) CI 6 07H06 CI 7 07H06 CI 86 07H06 CI 98 07H Available Special order Unavailable - CBD BD S- CBD Mechanical interlock Auxiliary contact block CBD for CI 6, CI 7, CI 86 and CI 98 contactors Contact function ) I e (-5) I th ) (-) Open Load I the ) (-) Encl. [A] [A] [A] [V] U e Code no. CBD- make (NO) + break (NC) H064 CBD- make (NO) + break (NC) H065 CBD S-NC break (NC) H066 CBD S-NO make (NO) H067 CBD S- make (NO) + break (NC) H069 CBD S-0 make (NO) H070 ) Force-actuated contacts suitable for safety switching. ) The thermal current Ith gives the maximum load at 40 C, which corresponds to installing the contactor in air (open). In CBD auxiliary contact the silver tips are cross-stamped. In CBD S auxiliary contact the silver tips are H-shaped. ) The thermal current Ithe gives the maximum load at 60 C, which corresponds to installing the contactor in an enclosure. Both contact types are PLC-compatible. Min. load 4 V, 0 ma. RCD- Clip-on marker Accessories for contactors CI 6, CI 7, CI 86, CI 98 Description Comments Code no. Mech. interlock Mech. interlock can be established between pairs 07H074 RCD 80 (0 80 V, 50/60 Hz) 07H07 Clip-on markers Rating plate with cover 07H4 Danfoss DCS (az) 08.0 IC.PD.C00.F6.0
3 Data sheet CI-TI Contactors and motor starters, s CI 6 - CI 98 Description Thermal overload relays TI 80 - TI 86 are used with contactors type CI 6, CI 7 and CI 86 to give overload protection of squirrel-cage motors of 0 55 kw. The relays trip under asymmetric load, i.e. accelerated release if phase drop-out occurs. Other features of TI 80 and TI 86: stop / reset button manual / automatic reset test button double scale for direct start or Y / D start signal contact with changeover Ordering Thermal overload relays TI 80 and TI 86 Motor starter Range Max. fuse ) Y / D starter gi, gl, gg BS 88, type T [A] [A] [A] [A] Code no. TI H06 TI H07 TI H08 ) To IEC coordination types and : Coordination type : Any type of damage to the motor starter is permissible. If the motor starter is in an enclosure, no external damage to the enclosure is permissible. After a short-circuit the thermal overload relay shall be partially or wholly replaced. Coordination type : No damage to the motor starter is permissible, but slight contact burning and welding is permissible. Base Selection of thermal overload relay The selection of a thermal overload relay must be based on the motor full load current and the method of starting: With direct start the motor starter range applies With star-delta start Y / D starter range applies Example: Full load current: 85 A With direct start, the suitable motor starter range is A, i.e. thermal overload relay 047H08 With star-delta start, the suitable Y/D starter range is A, i.e. thermal overload relay 047H06 Push button extension Accessories for thermal overload relays TI 80 - TI 86 Description Comments Code no. Clip-on markers For mounting on TI 80 - TI 86 (50-off ) 07H00566 Base For separate mounting of TI 80 - TI L Pushbutton extension For TI 9C TI- TI 86 ( mm) 047L Current rail set For direct mounting of TI 80 / TI 86 on contactors CI (set of ) 07H00866 Current rail set Danfoss DCS (az) 08.0 IC.PD.C00.F6.0
4 Data sheet CI-TI Contactors and motor starters, s CI 6 - CI 98 Construction standards Contactors, thermal overload relays and accessories are designed and tested in accordance with IEC 947/EN Environment Temperate climate Tested and passed in accordance with DIN and part 8 and IEC 68 Max. installation height: 000 NN, in accordance with IEC 947 Pulse voltage CI 6-CI 7-CI 86-CI 98 U imp 8 KV Ambient temperature Ambient temperature Operation Storage / Transport CI 6-CI 7-CI 86-CI 98-5 C 60 C -55 C 80 C Environment Temperature compensated Ambient temperature Vibration Shock perpendicular to contact system Max. operations per hour TI C C g at 00 Hz 9 g for 7.5 ms 0 Mounting direction Approvals EN LLC CDC TYSK CI 6 CI 7 CI 86 CI 98 TI 80 TI 86 Approved Rated life Mechanical life Operations Electrical life - Operations Duty cycles per hour - load Operations CI 6-CI 7-CI 86-CI 98 0 x 0 6 x Danfoss DCS (az) 08.0 IC.PD.C00.F6.0 4
5 Data sheet CI-TI Contactors and motor starters, s CI 6 - CI 98 Electrical life curves Contactors CI load categories, - Contactors CI , load categories - & 4 0% -4 Mixed operation of squirrel-cage motors; U e = V Contactors CI , load categories -4 Switching of squirrel-cage motors; U e = V Contactors CI , load categories - Switching of squirrel-cage motors while starting; U e = V A: Electrical life in millions of make / break operations. B: Rated Operating current (A). Danfoss DCS (az) 08.0 IC.PD.C00.F6.0 5
6 Data sheet CI-TI Contactors and motor starters, s CI 6 - CI 98 Tripping graphs TI 80 / 86 Explanation of graphs Mean value curves Upper curve: -phase tripping and asymmetric load tripping at min. setting Lower curve: Asymmetric load tripping at max. setting When tripping from the operationally warm condition, the tripping times are approx. 0% of the values shown. These values apply at an ambient temperature = 0 C. -phase tripping: x = Asymmetric load tripping: x = measured current rated motor current measured current max. scale value on overload relay Tripping time < T p 0 s at 7. I e class 0 A Note! In general, the thermal overload relay is always set on motor full load current. -phase overload. Measure overload current. Find the overload factor (x) by dividing the measured value by the set value of the thermal overload relay (motor full load current).. Find (x) on the horizontal axis and follow a line vertically up until it intersects the upper curve. 4. From the intersection point, follow a horizontal line to the left and read off on the vertical axis the time that will elapse before the thermal overload relay cuts out the motor. Asymmetric load tripping. Measure the current the motor draws from one of the intact phases.. Find the overload factor (x) by dividing the measured value by the maximum scale value of the thermal overload relay.. Find (x) on the horizontal axis and follow a line vertically up until it intersects the lower curve. 4. From the intersection point, follow a horizontal line to the left and read off on the vertical axis the time that will elapse before the thermal overload relay switch off the motor. Danfoss DCS (az) 08.0 IC.PD.C00.F6.0 6
7 Data sheet CI-TI Contactors and motor starters, s CI 6 - CI 98 Contact symbols and terminal marking CBD - CBD - CBD S - NO CBD S - NC CBD S - CBD S - 0 Contactors and thermal overload relay Contactors CI 6/7/86/98 Thermal overload relay TI 80/86 Danfoss DCS (az) 08.0 IC.PD.C00.F6.0 7
8 Data sheet CI-TI Contactors and motor starters, s CI 6 - CI 98 Connections Loads Connections, main contacts and contactor coils Connection method Single EN Without terminal sleeve Multicore With terminal sleeve Tightening torque [mm ] [mm ] [mm ] [Nm] CI 6, CI 7, CI 86, CI 98 Screw and box terminal TI 80, TI 86 Screw and box terminal Coil Screw and clamp washer Direct start, load categories -, -, -4 CI 6 CI 7 CI 86 Switching of -phase Motors; (50 Hz); Ambient temperature 60 C, -, -, -4 Rated loads at 50 Hz 0 0 V 40 V V 45 V 500 V 690 V A kw A kw A kw A CI 98 kw Star-delta start, load category - CI 6 CI 7 CI 86 Star-delta start, load category - Rated Loads at 50 Hz 0 0 V 40 V V 45 V 500 V 690 V A kw A kw A kw A CI 98 kw Three-phase ohmic load, load category - CI 6, CI7, CI86 - Active Power Load (50 Hz) Operating temperatur max. 40 C (open condition) Heat-resistant cable only (min 75 C) 0 0 V 40 V V 45 V 500 V 690 V A kw A CI 98 kw Three-phase ohmic load, load category - CI 6, CI7, CI86 - Active Power Load (50 Hz) Operating temperatur max. 60 C (encl. condition) Heat-resistant cable only (min 75 C) 0 0 V 40 V V 45 V 500 V 690 V A kw A CI 98 kw Switching three-phase power transformers (-6a) CI 6 CI 7 CI 86 CI 98 Switching of Power Transformers; -6a (50 Hz) Transformer load, (factor n = 0, inrush current = n x rated transformer current) 0 0 V 40 V V 45 V 500 V 690 V A kw A kw A kw A kw Danfoss DCS (az) 08.0 IC.PD.C00.F6.0 8
9 Data sheet CI-TI Contactors and motor starters, s CI 6 - CI 98 Technical data Switching lighting Incandescent lamps (-5b) Fluorescent lamps. individually compensated (-5b) Max. operating current Max. operating current [A] at operating tempereature ) Max. Capacity [uf] at Icc= [A] 40 C 60 C 0 ka 0 ka 50 ka CI CI CI CI Switching capacitor loads, individual capacitors (-6b) Inductance in leads between capacitors connected in parallel min. 6µH Max. Reactive power [kvar] ) 0 40 V V 500 V 690 V 40 C 60 C 40 C 60 C 40 C 60 C 40 C 60 C CI CI CI CI Switching capacitor loads, regulating capacitors (-6b) Inductance in leads between parallel-connected capacitors must be min.6µh Max. Reactive power [kvar] ) 0 40 V V 500 V 690 V 40 C 60 C 40 C 60 C 40 C 60 C 40 C 60 C CI CI CI CI Switching direct current load at 60 C ambient temperature Load categories DC- and DC-5, contacts connected in series Max. operating current [A] DC-. in series DC-5. in series 4 V 48 V 0 V 0 V 440 V 4 V 48 V 0 V 0 V 440 V CI CI CI CI Switching direct current load at 60 C ambient temperature Load category C-, contacts connected in series Max. operating current [A] 4 V 48 V 0 0 V 440 V pole pole pole pole pole CI CI CI CI Contact resistance and power loss Typical impedance Power loss at per pole Coil consumption Total power loss [W] [mω] - [W] - [W] CI CI CI CI Short-time withstand current I cw Current transfer time 0 sec. Min cooling Time Short time withstand current in Amps (Icw) [min.] CI CI CI CI ) 40 C is defined as non-enclosed installation. 60 C is defined as enclosed installation. Danfoss DCS (az) 08.0 IC.PD.C00.F6.0 9
10 Data sheet CI-TI Contactors and motor starters, s CI 6 - CI 98 Technical data (continued) Connections, auxiliary contacts CBD-, CBD S- For CI 6- CI 7 - CI 86- CI 98 Connection method Single and multi core without term. sleeve High capacity with term. sleeve Tightening torque [mm ] [mm ] [mm ] [Nm] Screw and clamp washer TI 80, TI 86 Screw and clamp washer , load categories -5 and - Comments -5 Max. operating current [A] V 40 V V 45 V 500 V 690 V 40 C ) 60 C ) CBD- For contactors CI 6- CI CBD S- CI 86 - CI ) 40 C is defined as non-enclosed installation. 60 C is defined as enclosed installation., load categories DC-, DC-, and DC-4 Max. operating current [A] Comments DC- DC- DC-4 4 V 48 V 0 V 0 V 440 V 4 V 48 V 0 V 0 V 440 V 4 V 48 V 0 V 0 V 440 V CBD- For contactors CBD S- CI 6- CI 7 - CI 86 - CI Coils, consumption and operating times CI 6- CI 7 - CI 86 - CI 98 Inrush power Holding-power Pull-in voltage Drop-out voltage Make time Break time [VA] [W] [VA] [W] [V] [V] [ms] [ms] (0.85.) x U S (0. 0) x U S RC Element (charge suppressor) Comments Overvoltage n = factor U max U n RCD Suitable for contactors CI 6, CI 7, CI 86 Max. load control circuit (contact system) Load Max. fuse -5 DC- gl, gl, gg BS 88 type T TI V, A, 00 VA 50 V, A, 0 W 4 A 6 A TI V, A, 00 VA 50 V, A, 0 W 4 A 6 A UL / CSA Specifications UL/CSA approved loads Motor load (-) [hp] Other loads (-) [A] -phase -phase UL CSA 5 V 0 V 00 V 40 V 460 V 575 V 40 C ) 60 C ) 40 C ) 60 C ) CI CI CI CI ) 40 C is defined as non-enclosed installation. 60 C is defined as enclosed installation., UL/CSA approved loads Comments [] Load capacity [DC] Category [VA] Category [W] CBD For contactors CI 6- CI 7 - CI 86-CI 98 A Q CBD S For contactors CI 6- CI 7 - CI 86-CI 98 A Q Connections, main contacts Connection method Single and multi core [AWG] Tightening torque [lb-in] CI 6, CI 7, CI 86, CI 98 Screw and clamp washer TI 80, TI 86 Screw and clamp washer Danfoss DCS (az) 08.0 IC.PD.C00.F6.0 0
11 Dimensions Contactor CI 6, 7, 86, 98 Contactor CI 6, 7, 86, 98 built together with thermal overload relay TI Drilling dimensions CI 6, 7, 86, 98 with mechanical interlock Thermal overload relays TI 80 and TI 86 for contactors CI 6, 7, 86 Thermal overload relays TI 80 and TI 86 Thermal overload relay TI 80 / TI 86 on base plate Danfoss DCS (az) 08.0 IC.PD.C00.F6.0
Contactor Types CI 61-98
MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories
More informationCI-TI Contactors and Motor Starters Type CI 6-50
Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components
More informationMini Contactors CI 4-
Data sheet Mini Contactors CI 4- Introduction CI 4 minicontactors cover the power range 1.5 to 5.9 kw and are available for a.c. and d.c. coil voltages. Characteristic of the minicontactors is that they
More informationCI-TI TM Contactors and Motor Starters Contactors CI 6-50
Data sheet CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Description Danfoss contactors CI 6-50 cover the power range 2.2-25 kw. CI 6 is built up as a combined contactor/control relay. CI 9
More informationMAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-
MKING MODERN LIVING POSSIBLE Technical brochure Minicontactors CI 5- www.danfoss.com 2 IC.PD.C10.F3.02-520B4167 Danfoss /S, C-SMC, mr, 07-2010 Contents Page Minicontactor CI 5- Introduction...............................................................................4
More informationLatch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5
3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V
More informationData sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427
Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This
More informationApproved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN
Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires
More informationTechnical Information
C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /
More informationModel Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1
Motor Contactor J7KN Range from 4 to 500 kw (AC 3, 380/415 V) AC and DC operated Integrated auxiliary contacts; integrated aux. contact of J7KN contactors up to 11kW suitable for electronic circuits Screw
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationKtec Contactors and thermal overloads
Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America
More informationApproved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More informationEssential equipment for all your requirements
NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides
More informationAF09... AF30 3-pole Contactors up to 20 HP / 480 VAC
AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationMotors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line
Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line 2 Contactores Compactos CWC0 Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors
More informationTechnical Information
Miniature Technical Information -09-12 Rated Insulation Voltage U i to IEC947-1 [V] 690V UL/CS [V] 600V Rated Impulse Voltage Withstand U imp [kv] 6 Rated Voltage Ue-Main Contacts C 50/60Hz [V] 230, 240,
More informationAF09... AF30 3-pole Contactors up to 25 HP / 600 VAC
AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24
More informationShort form catalogue. Motor protection & control
Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59
More informationAF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals
AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.
More informationTeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30
Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,
More informationIndustrial Contactors CTX 3 3P 185A - 800A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...
More informationContactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload
According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor
More informationApprobationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking
Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description
More informationCharacteristics TeSys contactors 0 TeSys k contactors and reversing contactors
90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp
More informationA Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.
C4 Miniature Contactors Contactors C4 Rated Insulation Voltage U i to IEC 947-1 [V] 500V UL/CS [V] 600V Rated Impulse Voltage U imp [kv] 8 Rated Voltage U e Main Contacts C 50/60Hz [V] 230, 240, 400, 415,
More informationAF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up
More informationBulletin 100-D IEC Contactors
Bulletin 100-D IEC Contactors Electronic and conventional coils AC & DC Integrated PLC interface Low power pick-up & hold-in Wide voltage ranges Complete range of accessories Environmentally friendly Compact
More informationIndustrial contactors CTX-1
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 Industrial contactors /04/05/10/12/14/15/20/22/24/25/30/32/34/35/40/42/44/45 CONTENTS PAGE 1. Use... 1 2. Range... 1 3. Electrical
More informationContactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660
Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays are the alternative to the thermal overload relays. An electronic overload relay offers reliable and fast protection
More informationControls. CONTACTORS CWB Line (up to 40A)
Controls CONTACTORS CWB Line (up to 40A) 0800 367 934 Contactors CWB Line (up to 40A) CONTACTORS CWB Line (up to 40A) Summary New WEG CWB Contactors 4 The Technology Within 6 Energy Savings 7 Easy Panel
More informationB6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data
B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1
More informationModular contactors and relays
pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation
More informationGV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features
Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator
More informationASL09..S 3-pole Contactors - Spring Terminals
4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil
More informationDescription. Positive safety relays
Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationAF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More information4 - Miniature controls
Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3
More informationTechnical Information
Contactors Contactors 95(-EI) 110(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 300-EI 420-EI 630-EI 860-EI Rated Insulation Voltage U i IEC, S, BS, SEV, VDE 0660 [V] 1000V UL; CS [V] 600V Rated Impulse Voltage
More informationElectronic overload relays EF205 and EF370
Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationContactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30
Contactors KNL KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30 Adaptable to various control requirements with ability of mounting from one to four additional auxiliary contacts. Versatile product capable
More informationStar Series Motor protection & control
Contact us ABB Inc. Low Voltage Control Products 16250 W. Glendale Drive New Berlin, WI 53151 Phone: 888-385-1221 Fax: 800-726-41 USA Technical support & Customer Service: 888-385-1221, Option 4 7:30AM
More informationSeries CA5 Contactors
Series C5 Contactors The contactor for heavy industrial applications from 500HP to 900HP DISCONTINUED This series is being replaced by the C9 Series of contactors C5 Series contactors provide large horsepower
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More informationVB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated
VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control
More informationMSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3
Introducing the New WEG Series. The was developed according to IEC 60947-3 & UL508. The compact, reliable design of the allows the operator to safely disconnect power and isolate the circuit within the
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More informationB115...B180 RF200 RFN200 B250...B400 RF400 RFN400
Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More informationThermal overload relay TF65 and TF96
Data sheet Thermal overload relay TF65 and TF96 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against overload and
More informationMODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)
MODULAR DEVICES The range of two, three and four pole isolator switches are of a modular design and fit on DIN 50022 rail. Terminal capacity is 25mm 2. Isolator Switches Rating Poles Modules Reference
More informationAF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits
More informationAE 9... AE 40 Contactors NE... Contactor Relays
Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal
More informationDATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.
DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN
More informationGeneral_technical_data Series
Slow-make switching element Switching system The double-break, slow-make switching element is equipped with one or two independent contact systems, acting as normally open or normally closed contact. The
More informationApplication Mini Contactors for Motors and Resistive Loads
Delivery program Contactor, 4p, 4kW/400V/AC3 Part no. DILEM4-G(24VDC) Catalog No. 012701 Eaton Catalog No. XTMF9A00TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads
More informationProtection Equipment
Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection
More informationApproved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories
Thermal Overload Relay J7TKN ) Thermal Overload Relay Direct and separate mounting Single phasing sensivity according to IEC 60947-4-1 Finger proof (BGV A2) Accessories Set for single mounting Approved
More informationMotor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88.
Motor Starters Star-Delta Starters Open Type 86 Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88 Accessories 89 Reversing Contactors 90 Pole Changing Starters 92 Technical Data 94 Wiring
More informationModular contactor for installation into distribution boards
Modular contactor for installation into distribution boards Description Modular contactors are used for installation in consumer units in dwellings, business premises, hotels, hospitals, shopping centres,
More informationProduct range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102
Overloadrelay,10-16A,1N/O+1N/C Partno. ZB12-16 Articleno. 290168 CatalogNo. XTOB016BC1 Deliveryprogramme Product range Overload relay ZB up to 150 A Frame size ZB12 Phase-failure sensitivity IEC/EN 60947,
More informationAF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationNSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals
NSL..S 4-pole / 8-pole Contactor Relays - Spring DC Operated Description - 1-stack contactor relays: 4-pole, - 2-stack contactor relays: 8-pole, - Mechanically linked contact elements available, - Low
More informationAF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationMini Contactors. Technical Catalogue. Type B6, B7 ABB
Technical Catalogue Mini Contactors Type B6, B7 ABB ABB Mini contactors B6/4 kw; B7/5.5 kw Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T7DU Contents Mini contactors
More informationTechnical Information
-100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42
More informationI r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.
DATASHEET - ZB12-2,4 Delivery program Overload relay, 1.6-2.4 A, 1N/O+1N/C Part no. ZB12-2,4 Catalog No. 278437 Eaton Catalog No. XTOB2P4BC1 EL-Nummer 0004131832 (Norway) Product range Overload relay ZB
More informationContact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France
Contact us ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F-69687 Chassieu cedex / France You can find the address of your local sales organisation on
More informationOther Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions
Installation Contactors Z-SCH These switching devices have been designed and rated particularly for modular installation in modular distribution boxes for electrical installation or cabinets with device
More informationOverloadrelay,10-16A,1N/O+1N/C. Articleno
Overloadrelay,10-16A,1N/O+1N/C Partno. ZB32-16 Articleno. 278452 CatalogNo. XTOB016CC1 Deliveryprogramme Product range Overload relay ZB up to 150 A Product range Accessories Accessories Overload relays
More informationModular Contactors and Switches D681E121
Modular Contactors and Switches D681E121 Modular Contactors and Switches Modular Contactors 2, 3 Aux. contact block 3 Accessories 3 Day Night Reloading Contactors 4 Safety Switches 5 Main Switches Emergency
More information3RT14 Contactors with 3 Main Contacts
3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Contactor Size 3RT14 46 Mechanical endurance Oper. 10 million Electrical endurance Oper. 0.5 million C-1 utilization category at I e
More informationThe contactor for large horsepower applications
Series The complete contactor for heavy industrial applications from 500HP to 900HP R Series contactors provide large horsepower performance with a design that is up to 40% smaller than traditional contactors
More informationD509E. Manual Motor - Starters
D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors
More informationMS25 59 MS RI RI RV 60, RV 120 RS 76 CDB3X 77 Surface Mounted (INO) and Flush Munted (IPO) Compact Distribution Boards 78
index Contents: Page New Products 4 Contactors K03, K07 Mini Contactors 10 BR6 Thermal overload relay 16 KNL6 - KNL30 Contactors 18 KNL6G - KNL30G Contactors 25 KNL40, KNL 65 Contactors 29 KNL80 - KNL110
More informationEmergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0
MainswitchSurfacemounting Partno. T0-2-1/I1/SVB-SW Articleno. 207148 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches
More informationTeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series
Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current
More informationThermal overload relay TF140DU and TF140DU-V1000
Data sheet Thermal overload relay TF140DU and TF140DU-V1000 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against
More informationContacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Wire size
Technical data UL Pilot Devices General UL technical data Contact blocks Rated insulation voltage, UL 600V Rated thermal current 10A / 600VAC 2.5A / 600VDC Minimum rating 24VDC, 5mA Mechanical life (millions
More informationContacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Low energy contacts gold plated. Minimum PUSHBUTTON
Pilot Devices Technical data UL General UL technical data Contact blocks Rated insulation voltage, UL 600V Rated thermal current 10A / 600VAC 2.5A / 600VDC Minimum rating 24VDC, 5mA Mechanical life (millions
More informationAF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.
More informationCapacitor Switching Contactors Type K3...-A, K3...-K
Type K3...-A, K3...-K Features that matter: Patented design with significant damping on inrush-current Long-life contactors tested by FRAKO up to 100,000 switching operations Suitable for unchoked and
More informationADS7 AC Contactor Starters
ADS7 AC Contactor Starters ADS7 starters fully comply with BS EN 60947-4-1, IEC 60947-4-1 and VDE 0660. The range offers a multitude of configurations and optional features including a complete choice
More informationUL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated
11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF
More information249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h
No Filter 81.6 % Auto 9.1 m3/h 250.0 m3/h Auto 99.7 m3/h 100.0 m3/h Auto 91.3 m3/h 92.0 m3/h Auto 40.0 m3/h 7. MW Auto 50.7 m3/h 50.0 m3/h 7.2 % Auto.6 % 45.0 % ABB NF Contactor Relays Overview...3 Ordering
More informationApproved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories
Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Positively guided contacts Screw fixing and snap fitting (35 mm DIN rail) Rated
More informationEmergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1
MainswitchSurfacemounting Partno. T0-2-8900/I1/SVB Articleno. 207151 CatalogNo. CT02-8900-I1CRQ Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More informationApprovals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking
MainswitchRearmounting Partno. T0-2-1/V/SVB-SW Articleno. 045992 Front IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches
More informationTechnical Information
Electrical Data C7-9 Rated Insulation Voltage U i IEC, S,BS,SEV, VDE 0660 [V] 690V UL; CS [V] 600V Rated Impulse Voltage U imp [kv] 8kV Rated Voltage U e -Main Contacts C7 3-Pole Contactors C7-2 C7-6 C7-23
More informationThermal overload relays Type TA Class 10
Thermal overload relays Type TA Class Thermal Overload relays Description Available for starter construction with A Line contactors and separate panel mounting Designed for close couple mounting Separate
More informationAF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440
More information5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors
Contents 0 - Contactors Selection guides.............................................page /2 b General, selection of contactors....................... pages /16 k contactors and reversing contactors b
More informationSD Series Non-Fused Load Switches
SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load
More informationTAE pole Contactors
TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges
More informationThe breakers offer thermal-magnetic trip protection according to Z and K characteristics.
Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific
More informationFMotor Circuit Controllers
Technical Information Motor Circuit Controller IEC Performance Data Catalog Number KTA7-25S...32S 0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A 20A 25A 29A 32A Rated Operational Current, I e [A]
More informationTHREE-POLE CONTACTORS series HR09-HR13 up to 6 kw
THREE-POLE CONTACTORS series HR09-HR3 up 6 kw USE Series HR contacrs are particularly suitable for controlling mors, heating elements and three-phase and single-phase loads in general. OPERATION AND INSTALLATION
More information