C -5 to +55 (0.8 to 1.1Uc) Permissible o

Size: px
Start display at page:

Download "C -5 to +55 (0.8 to 1.1Uc) Permissible o"

Transcription

1 T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC V 1000 Conforming to standards NFC63-110, VDE0660, BS5424, EM1038 & IEC pprovals UL, CS Degree of Protection Conforming to VDE 0106 Protection against direct finger contacts Protective treatment Standard version TH mbient air temperature Storage o C -60 to +80 (around the device) Operation o C -5 to +55 (0.8 to 1.1Uc) Permissible o C -40 to +70, for operation at Uc Maximum operating altitude Without derating Mtr Operating Position Without derating +30 o possible, in relation to normal vertical mounting plane Pole Characteristics Type TC1- Unit D09 D12 D18 D22 D25 D32 D38 D40 D50 D65 D80 D95 Number of poles Power + uxiliary or or - - or - - or - or or or Rated current (Ie) In C-3 θ < 55 o C Rated operating Voltage up to V Frequency limits Of the operational current Hz Rated thermal current (Ith) θ < 40 o C Rated making capacity Irms conforming to IEC Rated breaking capacity Irms conforming to V IEC V V verage impedence per pole t Ith and 50Hz Milli Ω Power dissipation per pole for C-3 W the above operational currents Control Circuit Characteristics Type Unit TC1- D09~D22 TC1- D25~D38 TC1- D40~D65 TC1- D80~D95 Rated control circuit voltage (Uc) 50 or 60 Hz V 12 to 660 Control voltage Operational Uc limits (θ < 55 o C) 50 or 60Hz Coil Drop out Uc 50/60Hz Coil Operational Uc at 60Hz verage consumption at 20 o C and at Uc C 50 Hz C 60 Hz Inrush Sealed Inrush Sealed 50 Hz Coil V /60 Hz Coil V COS φ Hz Coil V /60 Hz Coil V COS φ Hz Coil V /60 Hz Coil V COS φ Hz Coil V /60 Hz Coil V COS φ verage operating time at Uc Closing time C msec Opening time O msec Mechanical life Uc 50 or 60 Hz Coil 20(16 for TC1D18) (mechanical durability) in 50/60 Hz Coil or 50 Hz millions of operating cycles Maximum operating rate In operating cycle/hour Integral uxiliary Contact Characteristics Type Unit TC1- D09 ~ TC1- D95 Rated thermal current (Ith) θ < 55 o C 10 Rated operational voltage (Ue) up to V 660 1

2 T - Line Contactors 3 & 4 Pole Contactors with DC operating coils General Characteristics Type Unit TP1-D09 ~ TP1-D80 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC V 1000 Conforming to standards NFC63-110, VDE0660, BS5424, EM1038 & IEC pprovals CS, IEC Degree of Protection Conforming to VDE 0106 Protection against direct finger contacts Protective treatment Standard version TH mbient air temperature Storage o C -60 to +80 (around the device) Operation o C -5 to +55 (0.8 to 1.1Uc) Permissible o C -40 to +70, for operation at Uc Maximum operating altitude Without derating Mtr Operating Position Without derating +30 o possible, in relation to normal vertical mounting plane Pole Characteristics Type TP1- Unit D09 D12 D18 D22 D25 D32 D38 D40 D50 D65 D80 Number of poles Power + uxiliary or or - - or - - or - or or Rated current (Ie) In C-3 θ < 55 o C Rated operating Voltage (Ue) up to V Frequency limits Of the operational current Hz Rated thermal current (Ith) θ < 40 o C Rated making capacity Irms conforming to IEC Rated breaking capacity Irms conforming to V IEC V V verage impedence per pole t Ith and 50Hz Milli Ω Power dissipation per pole for C-3 W the above operational currents Control Circuit Characteristics Type Unit TP1-D09~D22 TP1-D25~D38 TP1-D4011~D65 TP1-D80 Rated control circuit voltage (Uc) DC V 12 to to 660 Control voltage Operational Standard Coil Uc Uc limits (θ < 55 o C) Wide Range Coil Uc Uc verage consumption DC at 20 o C and at Uc Drop out Uc Uc DC Inrush W Sealed W verage operating time at Uc Closing time C msec Opening time O msec Mechanical life Uc In millions of operating cycles (mechanical durability) Maximum operating rate In operating cycle/hour (at ambient temp. of θ < 55 o C) Integral uxiliary Contact Characteristics Type Unit TP1- D09 ~ TP1- D80 Rated thermal current (Ith) θ < 40 o C 10 Rated operational voltage (Ue) up to V 660 2

3 T - Line Contactors 3 & 4 Pole Contactors with C operating coil (For North merican market) 3 Pole Contactor with C operating coil TC1-D32 -XX TC1-D09008 TC2-D09 -XX Maximum Current Inductive Resistive C-3 C-1 Single Phase 120V 230V Maximum HP 200V Three Phase 230V TC1-D0910-XX 0 1 TC1-D0901-XX TC1-D1210-XX 0 1 TC1-D1201-XX TC1-D1810-XX 0 1 TC1-D1801-XX TC1-D2510-XX 0 1 TC1-D2501-XX TC1-D3210-XX 0 1 TC1-D3201-XX TC1-D4011-XX TC1-D5011-XX TC1-D6511-XX TC1-D8011-XX TC1-D9511-XX Note : Standard Fault Ratings High Fault Ratings (100k with Fuse of class /CC) 4 Pole Contactor with C operating coil Maximum Current Inductive Resistive C-3 3 Pole Mechanically Interlocked Contactor with C coil (Pre-wired) Inductive C-3 C-1 Maximum Current Resistive C-1 Single Phase 120V 230V Maximum HP 200V Maximum HP 3 Phase TC2-D0901-XX 1 0 TC2-D0911-XX TC2-D1201-XX 1 0 TC2-D1211-XX TC2-D1801-XX 1 0 TC2-D1811-XX TC2-D2501-XX 1 0 TC2-D2511-XX TC2-D3201-XX 1 0 TC2-D3211-XX TC2-D4011-XX TC2-D5011-XX TC2-D6511-XX TC2-D8011-XX TC2-D9511-XX Replace XX with voltage code from table - 1 Table-1 : XX-C Coil Voltages Volts C Hz L W T6 S6 X6 50/60 Hz B7 E7 F7 G7 - M7 P7 U7 - Q7 V7 N7 R V Three Phase 230V 600V ux. Contacts Built-in per contactor NO NC TC1-D09004-XX TC1-D09008-XX TC1-D12004-XX TC1-D12008-XX TC1-D25004-XX TC1-D25008-XX TC1-D40004-XX TC1-D40008-XX TC1-D50004-XX TC1-D50008-XX TC1-D65004-XX TC1-D65008-XX TC1-D80004-XX TC1-D80008-XX TC1-D95004-XX TC1-D95008-XX 480V 600V Main Pole Configuration NO ux. Contacts Built-in per contactor 200V 230V 480V 600V NO NC NC 3

4 T - Line Contactors 3 & 4 Pole Contactors with DC operating coil 3 Pole Contactor with DC operating coil TP1-D32 -XX Maximum Current Inductive Resistive C-3 C-1 Single Phase 120V 230V Maximum HP 200V Three Phase 230V TP1-D0910-XX 0 1 TP1-D0901-XX TP1-D1210-XX 0 1 TP1-D1201-XX TP1-D1810-XX 0 1 TP1-D1801-XX TP1-D2510-XX 0 1 TP1-D2501-XX TP1-D3210-XX 0 1 TP1-D3201-XX TP1-D4011-XX TP1-D5011-XX TP1-D6511-XX TP1-D8011-XX 480V 600V ux. Contacts Built-in per contactor NO NC Note : Standard Fault Ratings High Fault Ratings (100k with Fuse of class /CC) TP1-D0900 -XX 4 Pole Contactor with DC operating coil Maximum Current Inductive Resistive C-3 C-1 Single Phase 120V 230V Maximum HP 200V Three Phase 230V TP1-D09004-XX TP1-D09008-XX TP1-D12004-XX TP1-D12008-XX TP1-D25004-XX TP1-D25008-XX TP1-D40004-XX TP1-D40008-XX TP1-D50004-XX TP1-D50008-XX TP1-D65004-XX TP1-D65008-XX TP1-D80004-XX TP1-D80008-XX Note : Standard & High Fault Ratings 480V (100k with Fuse of class /CC) 600V Main Pole Configuration NO NC TP1-D12 -XX 3 Pole Mechanically Interlocked Contactor with DC coil (Pre-wired) Inductive C-3 Maximum Current Resistive C-1 Maximum HP 3 Phase Replace XX with voltage code from table - 2 ux. Contacts Built-in per contactor 200V 230V 480V 600V NO NC TP2-D0901-XX 1 0 TP2-D0911-XX TP2-D1201-XX 1 0 TP2-D1211-XX TP2-D1801-XX 1 0 TP2-D1811-XX TP2-D2501-XX 1 0 TP2-D2511-XX TP2-D3201-XX 1 0 TP2-D3211-XX TP2-D4011-XX TP2-D5011-XX TP2-D6511-XX TP2-D8011-XX 4 Table - 2: XX-DC Coil Voltages Volts DC D BD ED SD FD GD MD UD RD

5 T - Line Contactors ccessories, Spares Coils Power Connectors Wire Sets for T - Range Reversing Contactors T9-D1269 With Two Identical Contactors TC1-D09, TC1-D12, TP1-D09, TP1-D12 TC1-D18, TP1-D18 TC1-D25, TP1-D25 TC1-D32, TP1-D32 TP1-D40, TP1-D65, TC1-D40, TC1-D50, TC1-D65 TC1-D80, TP1-D80, TC1-D95 Mechanical Interlocks Horizontally Mounted T - Range Use for Contactor TC2-DN, TC3-DN TC1-D09 ~ D32, TP1-D09 ~ D32 TC1-D40 - D65, TP1-D40 - D65 TC1-D80 ~ D95, TP1-D80 Spare Coils (C) T - Range Use for contactor C TC1-D09~D18 TC1-D25~D32 TC1-D40~D95 Replace XX with voltage code from table - 3 T9-D1269 T9-D1869 T9-D2569 T9-D3269 T9-D6569 T9-D8069 *L9-D09978 L9-D50978 L9-D80978 TX1-D2-XX TX1-D4-XX TX1-D6-XX L9-D09978 approved Table-3: XX-C Coil Voltages Volts C Hz L6 W6 T6 S6 X6 50/60 Hz B7 E7 F7 G7 M7 U7 Q7 N7 R7 Spare Coils (DC) T - Range Use for contactor DC TP1-D09 ~ TP1-D18 TP1-D25 ~ TP1-D32 TP1-D40 ~ TP1-D65 TP1-D80 Replace XX with voltage code from table - 4 TX4-D2-XX TX4-D4-XX TX4-D40-XX TX4-D80-XX TX1-D -XX Table- 4: XX-DC Coil Voltages Volts DC D BD ED SD FD GD MD UD RD Mechanical Latching Blocks T - Range Description of Contactors For Contactors up to 32 mps Replace XX with voltage code from table - 5 / 6 L6DK01-XX For Mechanical Table-5: For C Voltage Latching Block L6-DK01 B E F G M U Q N R L6-DK01 approved For Mechanical Table-6: For DC Voltage Latching Block *L6-DK01 BD ED SD FD MD UD 5

6 T - Line Contactors Control Relays Characteristics Environment Type TC2DN TC3DN Conforming to Standards IEC 947-1, pprovals UL,CS Degree of Protection Protection against direct finger contact Conforming to VDE 0106 mbient air Temperature Storage C around the device Operation C Permissible for operation at Uc C Maximum operating altitude Without derating m 3000 Operating positions Without derating ±30 possible, in relation to normal vertical mounting plane Shock Resistance Control relay open 10g 8g 1/2 sine wave for 11 ms Control relay closed 15g 11g Vibration Resistance Control relay open 2g 2g 5 300Hz Control relay closed 4g 3g Cabling Flexible or solid cable with or without cable end mm 2 Min: 1x1; Max.: 2x2.5 Control Circuit Characteristics Type TC2DN TC3DN Rated Insulation Voltage (Ui) Conforming to IEC 947-1& IEC V 690 Conforming to CS C22-2 no. 14 V 600 Rated control circuit voltage (Uc) V Permissible voltage variation Operational With 50 or 60 Hz coil: With standard Hz coil: Uc Uc With 50/60Hz coil: With wide range coil: Uc Uc Voltage limits Drop-out Uc Uc verage consumption at 20 C ~ 50 Hz V Inrush: 60, Sealed:7 - ~ 60 Hz V Inrush: 70, Sealed:7.5 - ~ 50/60 Hz V Inrush: 70, Sealed:8 - With standard coil W - Inrush or Sealed: 9 With wide range coil W - Inrush or Sealed: 11 Operating Time Between coil energisation and ms (at rated control circuit voltage opening of the NC contacts and at 20 C) - closing of the NO contacts ms Between coil de-energisation and opening of the NO contacts ms closing of the NC contacts ms Short supply failures Max. duration without affecting ms 2 2 hold-in of device Maximum operating rate In operating cycles per second 3 3 Mechanical Life at Uc In millions of operating cycles 20 - With: 50 or 60 Hz coil (mechanical durability) 50/60 Hz coil (at 50 Hz) 30 - Standard coil - 30 Wide range coil - 30 Operating Power of Contactor with C Supply categories C-14 & C-15 Electrical life (up to 3600 operating cycles/hr) on an inductive load such as the coil of an electromagnet: making power (cosφ 0.7) - 10 times the power broken (cos φ 0.4) V / / / million operating cycles V million operating cycles V million operating cycles V Occasional making capacity V Breaking limit of contacts valid for maximum of 50 operating cycles at 10s intervals(breaking power=making power x cosφ 0.7) 2. Electrical life of Contacts: - for 1 million operating cycles (2a); - for 3 million operating cycles (2b); - for 10 million operating cycles (2C) 4. Thermal limit Operating Power of Contactor with DC Supply categories DC-13 Electrical life (up to 1200 operating cycles/hr) on an inductive load such as the coil of an electromagnet without economy resistor, the time constant increasing with the power. V million operating cycles V million operating cycles V million operating cycles V Occasional making capacity V Electrical life of Contacts: - for 1 million operating cycles (2a) - for 3 million operating cycles (2b) - for 10 million operating cycles (2C) 3. Breaking limit of contacts valid for maximum of 20 operating cycles at 10s intervals and with current passing for 0.5s per operating cycle. 4. Thermal limit

7 T - Line Contactors Control Relays Dimensions TC2-DN -XX TC3-DN -XX approved at 600V approved at 600V Control Relays (C) NO 2 2 TC2-DN22-XX 3 1 TC2-DN31-XX 4 0 TC2-DN40-XX Replace XX with voltage code from table - 7 Control Relays (DC) Replace XX with voltage code from table - 8 Table - 8: XX-DC Coil Voltages Volts DC D BD ED SD FD GD MD UD RD * For Independent Mounting Contacts NC Table-7 : XX-C Coil Voltages Volts C Hz L6 W6 T6 S6 X6 50/60 Hz B7 E7 F7 G7 M7 P7 U7 Q7 V7 N7 R7 Contacts NO NC 2 2 TC3-DN22-XX 3 1 TC3-DN31-XX 4 0 TC3-DN40-XX 7

8 F - Line Contactors Characteristics General Characteristics Type Unit LC1-FDP , LC1F-1154, LC1F-1504, LC1F-5004, LC1F-6304,L C1F-7804 Rated Insulation Voltage (Ui) (Conforming to IEC 158-1) V 1500 VDEO 110GRC/IEC V 1500 Conforming to Standards NFC63-110, VDEO660, BS5424, EM1038, IEC & IEC pprovals UL*, CS, IEC Protective treatment Standard Version TH mbient air temperature Storage o C -60 to +80 (around the device) Operation o C -5 to +55 (0.8 to 1.1 Uc) Permissible o C -50 to +70, for operation at Uc Maximum operating altitude Without derating Mtr Operating position Without derating +30 o possible, in relation to normal vertical mounting plane * - 4 Pole contactor under approval Pole Characteristics TYPE LC1-F UNIT Number of Poles (Power) 3 or 4 3 or or 4 3 or 4 3 or 4 Rated current (Ie) in C-3 θ< 55 C Rated operating voltage up to V Frequency limits of the operating current Hz Rated thermal current (Ith) θ< 40 C Rated making capacity Irms conforming to IEC Rated breaking capacity V Irms conforming to IEC V Control Circuit Characteristics 690V verage impedance per pole at Ith & 50 Hz MILLI Ω Power dissipation per pole for above operational current C-3 W Tightening Torque Power Circuit Nm Cabling Maximum CS No. of Bars Bar mm 20x3 25x3 25x3 32x4 32x4 30x5 30x5 40s5 60x5 100x5 Cable with Lug mm x150 2x Cable with connector Sqmm Bolt Diameter Sqmm xDia 14 TYPE (LC1-F) UNIT Rated control circuit voltage (Uc) 50 or 60 Hz V Control voltage limits Operational Uc Uc Uc Uc Temperature θ<55 o C Drop out Uc Uc Uc Uc verage consumption at 20 o C and at Uc, 50/60 Hz coil Operational verage consumption at 20 o C In rush 50 Hz coil V and at Uc, C 50 / 60hz In rush 60 Hz coil V In rush Hz coil V In rush Cosφ Sealed 50 Hz coil V Sealed 60 Hz coil V Sealed Hz coil V Sealed Cosφ verage operating time at Uc Closing time C msec Opening time O msec Mechanical life Uc (Mechanical 50 or 60 Hz coil Cycles durability) in millions of 50/60 Hz coil Cycles operating cycles Maximum operating rate In operating cycle/hour Tightening Torque Power Circuit Connection Nm Cabling Minimum / Maximum C.S. Flexible Cable without cable end 1or 2 Conductors Sqmm 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 Flexible Cable with end 1 Conductor Sqmm 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 Flexible Cable with end 2 Conductors Sqmm 1/2.5 1/2.5 1/2.5 1/2.5 1/2.5 1/2.5 1/2.5 1/2.5 1/2.5 1/2.5 Solid Cable without cable end 1 or 2 Conductors Sqmm 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 8

9 F - Line Contactors Contactors, Spare Coils - Contactors are without coil & uxiliary contacts, select the Coil & uxiliary contact separately 3 Pole Contactor with C or DC operating coil F - Range (coil sold separately) LC1-F185-XX Maximum Current Inductive C-3 Resistive C-1 Maximum HP Rating 200V 230V 480V 600V NO NC LC1-FDP LC1-FDP LC1-FDP LC1-FDP LC1-FDP LC1-FDP LC1-FDP LC1-FDP LC1-FDP Current rated 3 - LC1-FDP780 Note : V & V approved (only for Standard Fault Ratings) Main Pole Configuration LC1-F265-XX LX1-FF-XX 4 Pole Contactor with C or DC operating coil - F Range (coil sold separately) Inductive C-3 Maximum Current Resistive C-1 Maximum HP 3 Phase 200V 230V 480V 600V NO NC LC1-FDP LC1-FDP LC1-FDP LC1-FDP LC1-FDP LC1-FDP LC1-FDP LC1-FDP LC1-FDP Current Rated 4 - LC1-FDP7804 Note: 4P F-Range Contactors Coils F - Range (Replace XX with coil voltage code listed below) For Contactors listing under process C Main Pole Configuration F115 - F150 LX1-FF-XXXV LX4-FF-XXXV F185 - F225 LX1-FG-XXXV LX4-FG-XXXV F265 - F330 LX1FH-XXXV-2 LX4-FH-XXXV F400 LX1-F-XXXV LX4-F-XXXV F500 LX1-FK-XXXV LX4-FK-XXXV F630 LX1-FL-XXXV LX4-FL-XXXV F780 LX1-FX-XXXV LX4-FX-XXXV Substitute XX with voltage rating from Table -9 for C Coil & from table 10 for DC Coil Table-9: XX*-C Coil Voltages Contactor Volts C F115, F150 F185, F Hz F265, F Hz F400,F500,F Hz F Hz * If 24V, 50Hz Coil is required then replace XX with 24,50Hz DC Table-10: XX*-DC Coil Voltages Volt D C F115, F150, F185 F225, F265, F330 F115, F150, F185 F400,F500 F630 F780 Note : Protected shrouds for main poles or power poles to be ordered separately. 9

10 F - Line Contactors ccessories, Spares Mechanical Interlocks Horizontally Mounted F - Range For Contactor Type LC1-F115 LC1-F150 LC1-F185 LC1-F225 LC1-F265 LC1-F330 LC1-F400 LC1-F500 LC1-F630 L9-FF970 L9-FG970 L9-F970 L9-FL970 L9-FF970 Mechanical Interlocks Vertically Mounted F - Range For Contactor Type LC1-F115 LC1-F150 LC1-F185 LC1-F225 LC1-F265 LC1-F330 LC1-F400 LC1-F500 LC1-F630 LC1-F780 Power Connectors Wire Sets for F- Range Reversing Contactors L9-FF4F L9-FG4G L9-FH4H L9-F4 L9-FK4K L9-FL4L L9-FX970* L9-FX970*** LC1-F115 LC1-F150 LC1-F185 LC1-F225 LC1-F265 LC1-F330 LC1-F400 LC1-F500 LC1-F630 Main Contact Sets** F - Range With two identical contactors L9-FF976 L9-F15076 L9-FG976 L9-F22576 L9-FH976 L9-F976 L9-F976 L9-FK976 L9-FL976 For Contactor Type LC1-F115 LC1-F150 LC1-F185 LC1-F225 LC1-F265 LC1-F330 LC1-F400 LC1-F500 LC1-F630 LC1-F780 L5-FF431 (F115) L5-FF431 (F150) L5-FG431 (F185) L5-FG431 (F225) L5-FH431 (F265) L5-F (F330) L5-F (F400) L5-F (F500) L5-F (F630) L5-F (F780)*** * Double mechanical interlock mechanism with 2 interlock, connecting roads and 3 power connecting links ** For 3-pole contact (per pole: 2 fixed contacts and moving contacts, 2 deflectors, 1 back plate, fixing screws and washers). *** Set of main contacts provided is 1 set of 2 blocks for one pole 10

11 T & F - Line Contactors uxiliary Contacts, Time Delay Blocks, Mechanical Latching Blocks Instantaneous Time Delay Contact Characteristics Type UNIT T1D T2D T3D T8D Number of contacts 2 or Rated operational Voltage (Ue) up to V 660 Rated Insulation Voltage (Ui) Conforming to IEC V 690 Conforming to CS C22-2 No. 14 V Rated Thermal current (Ith) For ambient temperature <40 C 10 Frequency of operational current Hz Minimum switching capacity U min V 17 I min m 5 Short time rating Permissible for 1s ms ms 140 Insulation resistance MΩ >10 Time Delay mbient air temperature for operation C (T2D & T3D contact blocks) Repeat accuracy - ± 5% ± 5% ccuracy only valid for setting range Drift up to 0.5 million operating cycles + 15% + 15% indicated on the front face Drift depending on ambient air temp % per C 0.25% per C - Mechanical Life In millions of operating cycles Standard, instantaneous auxiliary contact blocks T1-DN22 T8-DN T1-DN20 No. of Contacts Pneumatic Timer Block (Front Mounted) Description Contacts Snap-On Mounting NO NC 2 2 T1DN T1DN To the front of T1DN TC1D09 to D80 LC1F T1DN TP1D09 to D32 & T1DN TC2DN / TC3DN T1DN T1DN T1DN To the front of T1DN TC1D40 to D95 TP1D40 to D80 T1DN To the side of T8DN TC1D09 to D95 TP1D09 to D32 & T8DN20 TC2DN / TC3DN Contacts NO NC Range ON Delay s T2-DT0 ON Delay s T2-DT2 ON Delay s T2-DT4 OFF Delay s T3-DR0 OFF Delay s T3-DR2 OFF Delay s T3-DR4 On Delay s* T2-DS2 * With switching time of 40msec + 15 msec between the opening of NC contact to the closing of NO contact (for Star Delta application) T2-DT2 11

12 F - Line & Single Pole Contactors ccessories, Spares Protective Shroud Covers for F-Range Contactors L9-F701 For 3P Contactor Type Catalogue Number For 4P Contactor Type Catalogue Number LC1-F115 L9-F701 LC1-F115 4 L9-F706 LC1-F150 L9-F702 LC1-F150 4 L9-F707 LC1-F185 LC1-F185 4 L9-F707 LC1-F225 LC1-F225 4 L9-F708 LC1-F265 LC1-F330 L9-F703 LC1-F400 LC1-F500 LC1-F500 4 L9-F708 LC1-F630 L9-F704 LC1-F630 4 L9-F709 Set of Power Connections* - Reversing Contactors for Motor Control - On Request For Contactor Type LC1-F115 LC1-F150 LC1-F185 LC1-F225 LC1-F265 LC1-F330 LC1-F400 LC1-F500 LC1-F630 L9-F11576 L9-F15076 L9-F18576 L9-F22576 L9-F26576 L9-F33076 L9-F40076 L9-F50076 L9-F63076 L9-FF970 Set of Power Connections - 3 Pole Changeover Contactor Pairs - On Request With two identical contactors LC1-F115 L9-F11582 LC1-F150 L9-F15082 LC1-F185 L9-F18582 LC1-F225 L9-F22582 LC1-F265 L9-F26582 LC1-F330 L9-F33082 LC1-F400 L9-F40082 LC1-F500 L9-F50082 LC1-F630 L9-F Pole Mechanically Interlocked F-Range Contactors - On Request Maximum Current C3 LC1-F115 LC1-F150 LC1-F185 LC1-F225 LC1-F265 LC1-F330 LC1-F400 LC1-F500 LC1-F630 LC2-F115 LC2-F150 LC2-F185 LC2-F225 LC2-F265 LC2-F330 LC2-F400 LC2-F500 LC2-F630 1 * Reversers assembled using two contactors of identical rating type etc. 2 Replace ** with available coils BD for 24V DC, ED for 48V DC and EED for 54V DC 12

13 T & F - Line Contactors Overload Relays Characteristics Environment Conforming to standards IEC , IEC , NFC , VDE 0660, BS 4941 pprovals *, CS, IEC Degree of protection Conforming to VDE 0106 Protection against direct finger contact IP 2X Protective treatment Conforming to IEC 68 TH mbient air temperature Storage o C -60 to +70 (around the device) Operation, without derating o C -25 to +60 Max. & Min. operating temp. o C -40 to +70 Operating position Without derating ny Position, in relation to normal vertical mounting plane Shock resistance Permissible acceleration 15gn - 11ms, conforming to IEC Vibration resistance Permissible acceleration 6gn, conforming to IEC Dielectric strength at 50 Hz Conforming to IEC KV 6 Impulse withstand voltage Conforming to IEC KV 6 Electrical Characteristics of Power Circuit TYPE TR2-D UNIT Tripping class Rated insulation Voltage (Ui) Conforming to IEC V Rated operating voltage upto Conforming to UL, CS V Rated impulse withstand voltage (Uimp) KV Frequency limits Of the operational current Hz Setting range Depending on model Connecting to screw clamp terminal Minimum / Maximum CS Flexible cable without cable end 1 conductor mm / / 10 4 / 35 4 / 50 Flexible cable with cable end 1 conductor mm 2 1 / 4 1 / 6 4 / 35 4 / 50 except TR2 21:1/4 Solid cable without cable end 1 conductor mm 2 1 / / 4 4 / 35 4 / 50 except TR2 21:1/6 Tightening torque Nm Connection to spring terminals Minimum / Maximum CS Flexible cable without cable end 1 conductor mm / / Solid Cable without cable end 1 conductor mm / / Operating Characteristics TYPE TR2-D UNIT Temperature Compensation o C Tripping Threshold Conforming to IEC In Sensitivity to phase failure Conforming to IEC Tripping current 30% of In on one phase, the others at In uxiliary Contact Characteristics Conventional thermal Current 5 Maximum consumption of operating C Supply V coil of controlled contactors (Occasional V operating cycles of contact 95-96) V W Short circuit protection By gg or BS fuse Max. rating 5 or by GB2 circuit-breaker Connection to screw clamp terminal Minimum / Maximum CS Flexible cable without cable end 1 or 2 conductors mm 2 1 / 2.5 Flexible cable with cable end 1 or 2 conductors mm 2 1 / 2.5 Solid cable without cable end 1 or 2 conductors mm 2 1 / 2.5 Tightening torque 1 or 2 conductors Nm 1.85 Connecting to spring terminal Minimum / Maximum CS Flexible cable without cable end 1 or 2 conductors mm 2 1 / 2.5 Solid cable without cable end 1 or 2 conductors mm 2 1 /

14 T & F - Line Contactors TR2-D25322 Standard Fault Ratings High Fault Ratings LR1-FM105 Standard Fault Ratings with T-Range Relay Bimetallic Overload Relay (Class 10), Base Plate for Independent Mounting RELY RELY STNDRD POWER RTINGS OF 3-PHSE MOTORS 50/60Hz, C3 CTEGORY BCK UP BSE REFERENCE SETTING RNGE 220V 380V 415V 440V 660V FUSE RTINGPLTE* () KW KW KW KW KW am() g1 () REFERENCE TR2-D to TR2-D to TR2-D to TR2-D to TR2-D to TR2-D to TR2-D093X to TR2-D to TR2-D to TR2-D to TR2-D to TR2-D to TR2-D to TR2-D to T7D0964 TR2-D to TR2-D to TR2-D to T7D3264 TR2-D to TR2-D to TR2-D to TR2-D to TR2-D to TR2-D to Overload Relays F - Range, (Independent Mounting) Note : RELY RELY STNDRD POWER RTINGS OF 3-PHSE MOTORS 50/60Hz, C3 CTEGORY BCK UP REFERENCE SETTING RNGE 220V 380V 415V 440V 660V FUSE RTING () KW KW KW KW KW am () g1 () LR1-F to LR1-F to LR1-F to LR1-F to LR1-F to LR1-F to LR1-F to LR1-F to LR1-F to LR1-F to LR1-F to Protected shrouds for main poles or power poles to be ordered separately. 14

15 Definite Purpose Contactors Technical Specifications Consult factory for availability 1 Pole without Shunt Full Load mps. (Inductive) C 240V C 277V Locked Rotor (Per Pole) C 480V C 600V Resistive mps Rating Catalog Number TCDP251-XX TCDP301-XX TCDP401-XX 1 Pole with Shunt Full Load mps. (Inductive) C 240V C 277V Locked Rotor (Per Pole) C 480V C 600V Resistive mps Rating Catalog Number TCDP251S-XX TCDP301S-XX TCDP401S-XX 2 Pole Full Load mps. (Inductive) C 240V C 277V Locked Rotor (Per Pole) C 480V C 600V Resistive mps Rating Catalog Number TCDP202-XX TCDP302-XX TCDP402-XX 3 Pole Full Load mps. (Inductive) C 240V C 277V Locked Rotor (Per Pole) C 480V C 600V Resistive mps Rating Catalog Number TCDP203-XX TCDP253-XX TCDP303-XX TCDP403-XX Replace XX with voltage code from table - 1 Table-1: XX-C Coil Voltages Volt C Hz B5 G5 L5 U5 W5 T5 60 Hz B6 G6 L6 U6 W6 T6 Purpose These contactors are used for control of Motors, Power Supplies, Heating Elements, Lighting, HVC Fans and Compressors. Environment Maximum operating altitude: 2000 meters above sea level mbient ir Temp: - 40 degree to + 65 degree C mbient air dampness around the device: 45 to 85% RH Coil supply voltage: 80% - 110% rated voltage Coil Data Voltage : 24, 120, 240 VC 50 & 60 Hz Normal V : Inrush 65V, Sealed 7.5V Duty Cycle : continuous Initial Insulation Resistance : 100-mega ohms minimum. pprovals 15

16 Notes 16

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors 90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp

More information

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30 Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,

More information

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660 Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,

More information

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC Product data sheet Characteristics LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 -

More information

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC Product datasheet Characteristics LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 -

More information

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC Product datasheet Characteristics LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 -

More information

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition Product datasheet Characteristics LC1F400E7 Complementary [Uimp] rated impulse withstand voltage Overvoltage category [Ith] conventional free air thermal current Main Range Product name Product or component

More information

Contactors. d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. References

Contactors. d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. References d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. c Standard power ratings Rated Instantaneous Basic reference. Weight of 3-phase motors operational auxiliary

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors

5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors Contents 0 - Contactors Selection guides.............................................page /2 b General, selection of contactors....................... pages /16 k contactors and reversing contactors b

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

Technical Information

Technical Information C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /

More information

LR9 F OVERLOAD RELAYS

LR9 F OVERLOAD RELAYS Issued November 2009 DATA SHEET LR9 F OVERLOAD RELAYS Based on Schneider MKTED2050EN Catalogue General 6 Motor protection Operating conditions There are many possible causes of electric motor failure.

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Contactor Types CI 61-98

Contactor Types CI 61-98 MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories

More information

Technical Information

Technical Information Miniature Technical Information -09-12 Rated Insulation Voltage U i to IEC947-1 [V] 690V UL/CS [V] 600V Rated Impulse Voltage Withstand U imp [kv] 6 Rated Voltage Ue-Main Contacts C 50/60Hz [V] 230, 240,

More information

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com TeSys D, K Catalogue 2017 'S335' series contactors for electrodomestic applications schneider-electric.com Presentation TeSys D, TeSys K TeSys D, TeSys K: S335 series Best-in-class contactors for electrodomestic

More information

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5- MKING MODERN LIVING POSSIBLE Technical brochure Minicontactors CI 5- www.danfoss.com 2 IC.PD.C10.F3.02-520B4167 Danfoss /S, C-SMC, mr, 07-2010 Contents Page Minicontactor CI 5- Introduction...............................................................................4

More information

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Data sheet CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Description Danfoss contactors CI 6-50 cover the power range 2.2-25 kw. CI 6 is built up as a combined contactor/control relay. CI 9

More information

Low Voltage. EasyPact TVS. Motor starters from 6A to 630A. Catalog 2015

Low Voltage. EasyPact TVS. Motor starters from 6A to 630A. Catalog 2015 Low Voltage EasyPact TVS Motor starters from 6A to 630A Catalog 2015 Designed for the essential EasyPact TVS General contents EasyPact TVS contactors, 6 A to 630 A A-1 EasyPact TVS thermal overload relays

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - HK1-11 HKF1-11 HK-11 HKS-20 uxiliary contacts Mounting uxiliary contacts position Pilot duty rating Instantaneous Lagging / leading / max. 116 132 5x 9x quantity ac dc NO NC NO NC 2 - - - HK1-20 Right

More information

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads. C4 Miniature Contactors Contactors C4 Rated Insulation Voltage U i to IEC 947-1 [V] 500V UL/CS [V] 600V Rated Impulse Voltage U imp [kv] 8 Rated Voltage U e Main Contacts C 50/60Hz [V] 230, 240, 400, 415,

More information

Series CA5 Contactors

Series CA5 Contactors Series C5 Contactors The contactor for heavy industrial applications from 500HP to 900HP DISCONTINUED This series is being replaced by the C9 Series of contactors C5 Series contactors provide large horsepower

More information

References Contactors 0 Reversing contactors for motor control in utilisation category AC-3 (115 to 265 A), pre-assembled Controlcircuit:a.c.ord.c.

References Contactors 0 Reversing contactors for motor control in utilisation category AC-3 (115 to 265 A), pre-assembled Controlcircuit:a.c.ord.c. s Contactors 0 Reversing contactors for motor control in utilisation category AC- ( to A), pre-assembled Controlcircuit:a.c.ord.c. 89 LC F -pole reversing contactors (horizontally mounted) () Pre-wired

More information

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30 Contactors KNL KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30 Adaptable to various control requirements with ability of mounting from one to four additional auxiliary contacts. Versatile product capable

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.

More information

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction Introduction Introduction Schneider Electric offers a complete line of products for the manual control and protection of motors. This catalog covers those devices designed to meet IEC standards for protection

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France Contact us ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F-69687 Chassieu cedex / France You can find the address of your local sales organisation on

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

Mini Contactors CI 4-

Mini Contactors CI 4- Data sheet Mini Contactors CI 4- Introduction CI 4 minicontactors cover the power range 1.5 to 5.9 kw and are available for a.c. and d.c. coil voltages. Characteristic of the minicontactors is that they

More information

Page 2-4 Page 2-8. Page Page 2-12

Page 2-4 Page 2-8. Page Page 2-12 Page -4 Page -8 THREE-POLE CONTCTORS IEC Ith ratings in C1 duty at 40 C: 16 to 1600 IEC Ie ratings in C3 440V duty: 6 to 630 IEC Power ratings in C3 400V duty:. to 335kW UL/CS ratings: 3 to 500HP at 480V

More information

The contactor for large horsepower applications

The contactor for large horsepower applications Series The complete contactor for heavy industrial applications from 500HP to 900HP R Series contactors provide large horsepower performance with a design that is up to 40% smaller than traditional contactors

More information

K30H001YP cam star-delta switch - 3-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

Industrial contactors CTX-1

Industrial contactors CTX-1 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 Industrial contactors /04/05/10/12/14/15/20/22/24/25/30/32/34/35/40/42/44/45 CONTENTS PAGE 1. Use... 1 2. Range... 1 3. Electrical

More information

Thermal overload relays Type TA Class 10

Thermal overload relays Type TA Class 10 Thermal overload relays Type TA Class Thermal Overload relays Description Available for starter construction with A Line contactors and separate panel mounting Designed for close couple mounting Separate

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489 Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection

More information

Manual Motor Protectors

Manual Motor Protectors 88 Manual Motor Protectors 51 30 UP TO IMM16 Frame IMM32 Frame IMM65 Frame E468295 E468295 High interrupt capacity up to 100k (with optional current limiter) Din rail mounting Lockable handle (OFF position)

More information

K50H004UP cam changeover switch - 4-pole A - screw mounting

K50H004UP cam changeover switch - 4-pole A - screw mounting Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

TeSys D Overload Relays

TeSys D Overload Relays TeSys D Contactors and Overload Relays TeSys D Overload Relays Table.24: TeSys D Overload Relays Ambient Compensated, Bimetallic, Direct Mounting Current Setting Range (A) For Direct Mounting to LC1...

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Controls. CONTACTORS CWB Line (up to 40A)

Controls. CONTACTORS CWB Line (up to 40A) Controls CONTACTORS CWB Line (up to 40A) 0800 367 934 Contactors CWB Line (up to 40A) CONTACTORS CWB Line (up to 40A) Summary New WEG CWB Contactors 4 The Technology Within 6 Energy Savings 7 Easy Panel

More information

US catalog. R contactors Control of AC and DC power circuits up to 5000 A

US catalog. R contactors Control of AC and DC power circuits up to 5000 A US catalog R contactors Control of AC and DC power circuits up to 5000 A Motor rated operational powers and currents The currents given below concern standard three-phase four-pole cage motors (1500 r.p.m.

More information

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Characteristics interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Stock Code: Stock - Normally stocked in distribution facility Price*: 4.20 USD Complementary Shape of pin Jul 8, 2015 Main Commercial

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

3RT14 Contactors with 3 Main Contacts

3RT14 Contactors with 3 Main Contacts 3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Contactor Size 3RT14 46 Mechanical endurance Oper. 10 million Electrical endurance Oper. 0.5 million C-1 utilization category at I e

More information

Technical Information

Technical Information Contactors Contactors 95(-EI) 110(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 300-EI 420-EI 630-EI 860-EI Rated Insulation Voltage U i IEC, S, BS, SEV, VDE 0660 [V] 1000V UL; CS [V] 600V Rated Impulse Voltage

More information

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line 2 Contactores Compactos CWC0 Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors

More information

MS25, MST25, MS20, MST20

MS25, MST25, MS20, MST20 Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440

More information

References 4 Fuse carriers

References 4 Fuse carriers References components 000_ -pole basic blocks Rating Cartridge fuse size umber of early break contacts () Single-phase protection device () Reference () Connection by spring terminals A 0 x 8 () Without

More information

and Refrigeration Institute). CNX Special Purpose Contactors

and Refrigeration Institute). CNX Special Purpose Contactors Series C7 Special Use Contactors Contactors designed and labeled for specific industrial applications Special Use Contactors Hydraulic elevator duty contactors HVC rated contactors Lighting contactors

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information

YS Series Contactors YS1N- F11 ****

YS Series Contactors YS1N- F11 **** YS Series YS Series Contactors Key features of the YS Series include: Compact size AC and C coil, reversing and non-reversing Weld-resistant silver alloy contacts No cadium used in contacts Highly reliable

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

MPW Series. MPW Catalog Number Sequence. Standard Features MPW U004

MPW Series. MPW Catalog Number Sequence. Standard Features MPW U004 Series The WEG Series Manual provide a very compact solution for operation and protection in motor control applications. The NEC requires four functions to be considered a combination motor starter:, ranch,

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

About us. Switchgear Factory, Mumbai

About us. Switchgear Factory, Mumbai About us Larsen & Toubro is a technologydriven USD 8.5 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering, Construction,

More information

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators Double insulated, types XCK-P and XCK-T Presentation XCK-P with 1 cable entry, conforming to CENELEC EN 57 With head for linear movement (plunger) operators Page 18 With head for rotary movement (lever)

More information

DATA SHEET LC-D CONTACTORS

DATA SHEET LC-D CONTACTORS Issued November 2009 DATA SHEET LC-D CONTACTORS Based on Shneider MKTED205103EN Catalogue Charateristis 5 d Contator type LC1 D09 D18 D25 D38 D40 D50 D95 D115 and D150 DT20 and DT25 DT32 and DT40 Environment

More information

NB1 Miniature Circuit Breaker

NB1 Miniature Circuit Breaker P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101428D0201 28/03/11 -.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)

More information

Star Series Motor protection & control

Star Series Motor protection & control Contact us ABB Inc. Low Voltage Control Products 16250 W. Glendale Drive New Berlin, WI 53151 Phone: 888-385-1221 Fax: 800-726-41 USA Technical support & Customer Service: 888-385-1221, Option 4 7:30AM

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Contactor TECHNICAL INFORMATION - FRAME 1

Contactor TECHNICAL INFORMATION - FRAME 1 TECHNICL INFORMTION - FRME 1 CONTCTOR Type No. Nominal Current Rating at 415v 50Hz C3 - Ie Contact Configuration* Rated Insulation oltage Ui Maximum Operational oltage Overall Dimensions (WxHxD) mbient

More information

6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate

More information

Contactors and Overload Relays

Contactors and Overload Relays Contactors and Overload Relays Catalogue 2011 2 CONTENT Contactor Introduction...4 Range over view...8 Technical information - CN Series...10 Add on accessories - CN Series...12 Accessory fitment over

More information

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1

More information

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads 22 Series - Modular contactors 25-40 - 63 22 SERIES Features 22.32.0.xxx.1xx0 22.32.0.xxx.4xx0 25 modular contactor - 2 pole 17.5 mm wide NO contact gap 3 mm, double break Continuous duty for the coil

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control

More information

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1 Motor Contactor J7KN Range from 4 to 500 kw (AC 3, 380/415 V) AC and DC operated Integrated auxiliary contacts; integrated aux. contact of J7KN contactors up to 11kW suitable for electronic circuits Screw

More information

Low Voltage Industrial Controls. CWB and RW27-2D. IEC Contactors and Thermal Overload Relays

Low Voltage Industrial Controls. CWB and RW27-2D. IEC Contactors and Thermal Overload Relays CWB and RW27-2D IEC Contactors and Thermal Overload Contactors Overload A-2-800-ASK4WEG www.weg.net/us Contactors CWB CWB Features A-4 Catalog Number Format A-7 Accessories Overview A-8 Part Number List

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information