ELECTRICAL CHARACTERISTICS. Permissible overload (A) 22 > transformer 42 > > > > >
|
|
- Solomon Thompson
- 5 years ago
- Views:
Transcription
1 New range of plugs and socket-outlets meeting the dimensional, construction/performance and safety requisites defined by the international Standards IE and IE , subsequently assimilated at European level as EN and EN Technical data and compliance with Standards EETRI RTERISTIS Rated current (In) () Rated frequency (z) Rated voltage Un (V) Permissible overload () No. of operations carried out reaking capacity at 1.1 Un () Insulation resistance (MΩ) 16 50/60 22 > > > transformer 32 direct current 42 > /60 > > > direct current > > 10 > 10 MENI ND PYSI RTERISTIS Operating temperature ( ) Degree of protection (IP) Impact resistance (IK) eat resistance Thermo-pressure with ball ( ) Resistance to abnormal heat and fire Glow wire test ( ) Straight plugs and sockets P*: IP44/IP54 e IP66/IP67/IP68/IP69 Straight plugs and sockets P: IK flush-mounting sockets P: IP44/IP54 e IP66/IP67 10 flush-mounting sockets P: IK (active parts) 80 (passive parts) 850 (active parts) 650 (passive parts) Other: IP44 e IP67 Other: IK 08 (*) lthough the international product standard EN does not currently require it, these products have been voluntarily subjected to tests with degrees of protection higher than IP66/IP67. IP68: 2 bar/6 h according to EN standard after aging test in conformity with EN standards. IP69: according to IE standard after aging test in conformity with EN standards. EVIOUR WIT EMI ND TMOSPERI GENTS Saline solution cids ases Solvents Mineral oncentrated Diluted oncentrated Diluted exane enzol cetone lcohol oil UV rays Resistant Not resistant imited resistance imited resistance Resistant Resistant Resistant Resistant Resistant Resistant Resistant 1
2 Wiring information - Plugs and sockets Rated current (In) () TIGTENING PITY OF TE TERMINS (mm 2 ) Flexible cables Rigid or stranded cables MIN. MX. MIN. MX TIGTENING PITY OF TE E FSTENER MP * (mm) Rated current (In) () No. poles MIN. MX. 2P P P + N P P P + N P ** 3P P + N P ** 3P P + N (*) N: these values refer to flexible, rigid and stranded cables. (**) ontact ST customer service for indications of the cable size to be used in order to maintain the IPX8 degree Dimension tables - Plugs and sockets STRIGT PUGS - IP44/IP TYPE D ød STRIGT PUGS - IP66 / IP67 / IP68 / IP TYPE ø 2
3 STRIGT ONNETORS - IP44/IP54 TYPE D ød STRIGT ONNETORS - IP66 / IP67 / IP68 / IP TYPE ø 10 FUS-MOUNTING SOKET-OUTETS - IP44/IP54 E 10 Ø d G F I (SREW) (SPRING) D R TYPE D E F G I ød R
4 10 FUS-MOUNTING SOKET-OUTETS - IP66 / IP67 E 10 G Ø d F R I (SREW) Y (SPRING) D TYPE D E F G I Y ød R Dimension tables - Flush-mounting domestic socket-outlets FUS-MOUNTING SOKET-OUTETS GERMN STD 85X75 MM - IP ø GW62392 FUS-MOUNTING SOKET-OUTETS GERMN OR FREN STD 50X50 MM - IP GW62393 and GW
5 Dimension tables - Plugs and sockets STRIGT PUGS - IP44/IP54 STRIGT PUGS - IP66 / IP67 / IP68 / IP69 Ø STRIGT ONNETORS - IP44/IP54 Ø ØD Ø 63 TYPE TYPE TYPE D
6 10 STRIGT ONNETORS - IP66 / IP67 / IP68 / IP TYPE Ø 10 FUS-MOUNTING SOKET-OUTETS - IP44/IP54 E D ød G F R I 63 TYPE D E F G I ød R FUS-MOUNTING SOKET-OUTETS - IP66 / IP67 E 10 ød R G F I D TYPE D E F G I ød R
7 Dimension tables - Plugs and sockets IE 309 PROTETED 90 MOIE PUGS - IP 44 WTERTIGT 90 MOIE PUGS - IP TYPE Pg 2P P P + N P P P + N TYPE Pg 2P P P + N P P P + N FUS-MOUNTING PROTETED FIXED PUGS - IP 44 FUS-MOUNTING WTERTIGT FIXED PUGS - IP TYPE D E 2P P P + N P P P + N TYPE D E F 2P P P + N P P P + N
8 SURFE-MOUNTING PROTETED 90 FIXED PUGS - IP 44 SURFE-MOUNTING WTERTIGT 90 FIXED PUGS - IP TYPE D E 2P P P + N P P P + N TYPE D E Pg 2P P P + N P P P + N P P P + N P P + N SURFE-MOUNTING PROTETED 10 FIXED SOKET-OUTETS - IP44 SURFE-MOUNTING WTERTIGT 10 FIXED SOKET-OUTETS - IP67 TYPE D E F Pg TYPE D E F Pg 2P P P + N P P P + N P P P + N P P P + N P P P + N
9 SURFE-MOUNTING PROTETED 90 FIXED SOKET-OUTETS -IP44 SURFE-MOUNTING WTERTIGT 90 FIXED SOKET-OUTETS - IP67 TYPE D E F 2P P P + N P P P + N TYPE D E F Pg 2P P P + N P P P + N P P P + N P P
ELECTRICAL CHARACTERISTICS. Permissible overload (A) 22 > transformer 42 > > > > >
IEC 309 TS New range of plugs and socket-outlets meeting the dimensional, construction/performance and safety requisites defined by the international Standards IEC 60309-1 and IEC 60309-2, subsequently
More informationPermissible overload. 22 A > A Hz > Hz 42 A > A. Heat resistance
IEC 309 HP technical characteristics New range of plugs and socket-outlets meeting the dimensional, construction/performance and safety requisites defined by the international Standards IEC 60309-1 and
More informationIEC 309 RANGE PLUGS AND SOCKETS TO IEC 309 STANDARDS
IC 309 RNG PLUGS ND SOCKTS TO IC 309 STNDRDS TCHNICL CHRCTRISTICS 1 SL / 3 SL - RPID SSMLY ND WIRING PLUGS ND SOCKTS RFRNC STNDRDS The IC 309 SL industrial plugs and sockets meets the dimensional, construction-performance
More information67 IB INTERLOCKED SOCKET-OUTLET IEC 309 STANDARDS
Technical data and compliance with Standards Component Interlocked switched socket-outlets SELV socket-outlet Rotary switch MT60 miniature circuit breaker, C characteristic, 6kA Reference Standards EN
More informationRated current In (A) Other electrical data. IEC 309 range. EN see 70 RT range IK
44 and 67 IB standard horizontal and vertical socket-outlets Industrial-type socket-outlets conforming to IEC 309 Standard, with mechanical interlock consisting of a circuit breaker enabling the plug to
More informationGreen Wall FIXING METHODS FOR GREEN WALL PRODUCTS. Fixing on a metal frame
IXING MTHOS OR GRN WLL PROUTS nclosures and distribution boards rticles On metal frame On sheet On masonry wall Junction boxes oxes for interlocked socket-outlets 67I and 44I oxes for domestic ranges -
More informationTechData. Master data. P/N: SCM460MI7W INTERLOCK SOCKET 3P+E IP67 60A 7h **Supplied with base
ddendum 1/11/1 rticle Picture P/N: SCM0MI7W INTERLOCK SOCKET P+E IP7 0 7h **Supplied with base 79.0 P/N SCM0MI7WNB INTERLOCK SOCKET P+E IP7 0 7h **No base supplied. Select base below. Base Options: Single:
More informationADVANCE GRP Series 125A Switched Interlocked socket outlets
DVNCE GRP Series 125 Switched Interlocked socket outlets DVNCE GRP Series 125 > SWITCHED INTERLOCKED SOCKET OUTLETS > REFERENCE STNDRDS EN 60309-1 Plugs, socket outlets and couples for industrial purposes.
More information70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX
70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX SWITCH DISCONNECTORS IN METAL BOX ATEX SWITCH DISCONNECTORS IN METAL BOX The switch disconnectors in plastic boxes, which are available in control or emergency
More informationIS OL ATOR S S E RIE S. Enclosed change-over switches I/O/II
IS OL TOR S S E RIE S Enclosed changeover switches I/O/II ISOLTORS Series ENCLOSED CHNGEOVER SWITCHES I/O/II, 0 1 Poles IP degree IP65(*) 1/5 IP65(*) 1/5 IP65(*) 1/5 IP65(*) 1 IP65(*) 1 THERMOPLSTIC LUMINIUM
More informationCOMMAND Series. Switching-disconnectors units
COMMND Series Switchingdisconnectors units COMMND Series > ROTRY SWITCHES > REFERENCE STNDRDS EN 6097 Low voltage switchgear and controlgear. Part : switches disconnectors, switchdisconnectors and fusecombination
More informationPlug 16A 2P+E extra flat Wireable (body length up to 50 mm) SPA17. Plug 10A 2P+E straight S11. Plug 16A 2P+E straight S30. Plug 16A angled S30
CONTROL DEVICE REFERENCE STANDARDS UNSWITCH SOCKET OUTLETS EN 60669-1 Switches for household and similar fixed-electrical installation. Part 1: general requirements. Rated current: 10A-13A-15A-16A Rated
More informationTUNNEL54. Safety and fire resistance VENTILATION LIGHTING
TUNNEL54 Safety and fire resistance VENTILATION LIGHTING 238 TUNNEL54 Safety and fire resistance VENTILATION TUNNEL54 fire resistant sockets for ventilators Page 240 LIGHTING TUNNEL54 junction boxes with
More informationDOMINO Series surface mounting IP55
Series surface mounting IP55 SERIES CONSUMER UNITS SURFACE MOUNTING VERSION - IP55 REFERENCE STANDARDS International standard IEC 60670 (989) and the Modification (994) Part : General requirements for
More informationAmphenol. Amphe 309 PIN & SLEEVE. IEC & UL Industrial plug, sockets-outlets & mechanical interlocks.
mphe 309 PIN & SLEEVE IE & UL Industrial plug, sockets-outlets & mechanical interlocks 97 Series onnectors are UL recognized and S recognized. INDUSTRY EXMPLES Marinas LVS old Ironing Data enters 309 309
More informationDistribution boards. 68 Q-DIN Range
Complete electric boards system for energy distribution in commercial, industrial and costrucion sites places. Available in both empty and wired version, in compliance with the IEC 61439 Standard: Versions
More informationP17 plugs, mobile sockets and surface-mounting sockets «New range 16 and 32 A»
87045 LIMOGES Cedex Telephone : + 33 0 5 55 06 87 87 - Fax : + 33 0 5 55 06 88 88 P7 plugs, mobile and surface- Cat. Nos. : 555 53/57/58/73/77/78-5 53/57/58/73/77/78 CONTENTS Page 575 4. Definition....
More informationApplication Coding Cable diameter Color Part No. Std. Pack Part No. Std. Pack. Female connector. gray black gray black gray black green
Connectors Connector for cables of Ø 6 10 and 10 14 mm With spring clamp connections for rigid cables of 0.5 2.5 mm 2, f fine-stranded cables of 0.5 1.5 mm 2 with ferrules, stranded cables of 0.75 1.5
More informationHYPRA Prisinter 16/32/63 A
8704 LIMOGES Cedex Telephone: + 33 0 06 87 87 - Fax: + 33 0 06 88 88 HYPR Prisinter 16/32/63 Page 1. General characteristics........1 2. Range......................1 3. Dimensions............... 2-3 4.
More informationUNIBOX Series Enclosure and wiring accessories IP40-IP55
UNIBOX Series Enclosure and wiring accessories IP-IP55 UNIBOX Series > ENCLOSURE FOR WIRING ACCESSORIES > REFERENCE STANDARDS EN 60670-1 Boxes and enclosures for electrical accessories for household and
More informationSafety Performance WORLD PREMIERE. palazzoli.com 1
Safety Performance WORLD PREMIERE palazzoli.com 1 The inventions that progressed our life Benjamin Franklin Energy and persistence conquer all things. The lightning rod 2 The inventions that progressed
More informationContainer plugs and sockets. SpeedPRO. Ergonomic, robust, safe, fast and accurate connections.
ontainer plugs and sockets SpeedPRO Ergonomic, robust, safe, fast and accurate connections. SpeedPRO plication Position of the earthing contact Reefer ontainer installations h 3 2 PLUS ND SOKETS IP67 mobile
More informationBOXES AND BOARDS. Versatility and modularity of solutions and materials STANDARD HEAVY DUTY
BOXES AND BOARDS Versatility and modularity of solutions and materials STANDARD HEAVY DUTY 8 BOXES AND BOARDS Versatility and modularity of solutions and materials STANDARD PRIMA topter empty distribution
More informationOMNIA System OMNIA SYSTEM - IP55 FLUSH AND SURFACE MOUNTING MODULAR SYSTEM. t. 50
OMNIA System OMNIA SYSTEM - IP55 FLUSH AND SURFACE MOUNTING MODULAR SYSTEM The flush mounting box, which is suitable for walled installations, can be combined both horizontally and vertically with any
More informationHEAVY-DUTY PLUGS & SOCKETS
HEAVY-DUTY PLUGS & SOCKETS 315 A/400 A/500 A/600 A Up to 600 A/1 000 V Automatic IP66/IP67 water-and dust-tight Mechanical and electrical interlocking Up to 6 auxiliary and 2 pilot contacts Marine aluminum
More informationINDUSTRIAL PLUGS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates
INDUSTRIAL PLUGS A range from 16 A to 600 A 1000 V. Automatic watertightness from IP44 to 66/67. From -40 to +240 C. GRP or metal casing. Reliable & compact. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com
More informationProducts for. Section
2 Products for Section Chemical Industries Grain silos Oil and Gas industry Plastics Fertilisers and insecticides Wood Cosmetics and perfumes lcohol and spirits Pharmaceutical Industries, etc. 90 2005-2006
More informationDimensions / Technical Data / Order Codes
Fluid Level / Temperature Indicators / / rder odes Level Gauge SN D Design of Scale Plates Thermometer ptions apillary Tube Thermometer with a dual elsius / Fahrenheit scale up to +80 / +80 F L3 YUR LG
More informationDECONTACTOR FOR INDUSTRY 30 A/50 A/90 A/150 A/250 A/ 400 A
DS DEONTATOR FOR INDUSTRY 30 A/50 A/90 A/150 A/250 A/ 400 A Atomatic IP54/55 Optional IP66 from 90 A Integrated load break switch: A-22 and A-23 breaking capacity hemical resistant GRP UL 94 casing p to
More informationHypra and P 17 industrial sockets
[ INUSTRIL SOKTS ] Products and systems ypra and P 17 industrial sockets 2 ranges cover 3 levels of weatherproofing: IP 44, IP 66/67 and IP 66/67-55: ypra is recommended for harsh environments (dust, water
More informationIS OL ATORS-EX S ERIES
IS OL ATORS-EX S ERIES Switch disconnectors for applications in potentially explosive atmospheres - DUST [ ] II 2D [ II 2D] SWITCHES DISCONNECTORS REFERENCE STANDARDS EN 60079-0 Electrical apparatus for
More informationPlugs, mobile sockets, panel mounting sockets, surface mounting sockets, P17 Tempra Pro IP44 and low voltage 66/67
Pro and low voltage 66/67 ONTENTS Page 1.Generalcharacteristics...1 2.Use...1 3. Range/Equivalence table.................1 4. Dimensions..............................3 5.Technicalcharacteristics...6 6.Installation...7
More informationMicro-D Printed Circuit Board Connectors
PB Printed ircuit Board onnectors ondensed Board Straight BS.075 Inch Spacing Save Space On Your ircuit Board These connectors feature.075 inch row spacing. The board footprint is reduced to match the
More informationJUMO MIDAS Pressure transmitter
Phone: +44 19 635533 Fax: +44 19 6356 Data Sheet 401001 Page 1/5 JUMO MIDAS Pressure transmitter Brief description Pressure transmitters are used for measuring the relative (gauge) pressure in liquids
More informationADVANCE- GRP S YS TEM. Switched Interlocked socket outlets [ ]
DVNCE GRP S YS TEM Switched Interlocked socket outlets DVNCEGRP System SWITCHED INTERLOCKED SOCKET OUTLETS 63263 REFERENCE STNDRDS EN 60309 Plugs, socket outlets and couplers for industrial purposes. Part
More informationADVANCE System ADVANCE SYSTEM IP66 MODULAR SYSTEM FOR COMBINATION UNITS VERSIONS MODULE 136 MODULE 106. t. 56. Without protective devices
ADVANCE System ADVANCE SYSTEM IP66 MODULAR SYSTEM FOR COMBINATION UNITS Without protective devices Interlocked-switch socket outlets QUADRA Series socket outlets For 16 and 32 A currents Protection degree
More information16/32/63A - IP44 plugs, mobile sockets, socket inlets and appliance inlets
87045 LIMOGES edex Telephone: (33) 05 55 06 87 87 - Fax: (33) 05 55 06 88 88 16/32/ - IP44 plugs, mobile sockets, Page 1. General data.... 1-2 2. Range.... 2-10 3. imensions.... 11-15 4. Technical data...
More informationSocket. Extension. Connector Box. Extension. IP 44 and IP 66/67 plugs, mobile sockets, socket outlets and appliance inlets
87045 LIMOGS edex Telephone : + 33 5 55 06 87 87 - Fax : + 33 5 55 06 88 88 IP 44 and IP 66/67 plugs, mobile sockets, ONTNTS Page 1. General characteristics.........1 to 2 2. Range......................2
More informationGENERAL CATALOGUE Leading Electrotechnology
GENERAL CATALOGUE 2014-2015 Leading Electrotechnology THE WORLD HAS CHOSEN PALAZZOLI excellence FROM ITALY The globalisation process no longer allows for Made in Italy to be the only mark of differentiation
More informationScrew-in thermometer with connection lead Model TF37
Electrical temperature measurement Screw-in thermometer with connection lead Model TF37 WIKA data sheet TE 67.12 Applications Mobile hydraulics Machine building Compressors Automotive Cooling, heating,
More informationMETAL. consumer UNITS DOMESTIC CIRCUIT PROTECTION MANUFACTURED IN THE UK
METL consumer UNITS OMESTI IRUIT PROTETION MNUFTURE IN THE UK P O W E R E Y S P E I L I S T S eyond the regulations Legrand s new range of metal consumer units does much more than meet the requirements
More informationINDUSTRIAL DECONTACTOR & CONNECTOR SYSTEMS
COLTERLEC ELECTRICL ENGINEERING PRODUCTS SECTION INDUSTRIL DECONTCTOR & CONNECTOR SYSTEMS Industrial Decontactor & Connector Systems COLTERLEC ELECTRICL ENGINEERING PRODUCTS 385 TM Industrial Decontactors
More informationMotor Protection Circuit Breakers 3VU13 and 3VU16
Motor Protection Circuit Breakers 3VU13 and 3VU16 3VU13/3VU16 is suitable for use in fuseless motor feeders upto 11KW/22KW (25A/63A) respectively. 3VU motor protection circuit breakers are used for protection
More informationENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue
ENEC LICENCE Licence No. ENEC-01360 Page 1/3 Date of Issue 2016-03-04 Licence Holder WAGO KONTAKTTECHNIK GMBH & CO KG HANSASTRASSE 27 MINDEN, 32423 Germany Production site WAGO CONTACT SA ROUTE DE L'INDUSTRIE
More informationWaterproof Series Waterproof
Waterproof Series Waterproof Technical Data Panel connector Panel connector, cable connector and coupler connector circular housing Locking screw connection Protection IP 65 with flat-gasket for panel
More information68 Q-DIN Range. Trade Catalogue Energy 2013 > Energy > Combined units to IEC 309 > 68 Q-DIN Range. Distribution boards UNWIRED VERSIONS
Kombi cent r al er 0 8 5 9 41 1 83 0 www. mwa. s ei nf o@mwa. s e UNWIRED VERSIONS Type No. EN 50022 modules 1 IEC 309 socket-outlet 16A IP44/67 or GW 27 401 or GW 27 403 watertight cap GW 68 018 N 2 IEC
More informationMaximum performance. Always.
54 Maximum performance. Always. Rotary control devices in box A23A A3 INSTALLATION LASS, ONDITIONAL SHORT IRUIT URRENT 0,000A. THEY ALLOW DIRET ONTROL OF HIGHLY INDUTIVE LOADS. THEY ELIMINATE OSTLY MAHINE
More informationDNROBUST DECONTACTOR 20 A / 30 A / 50 A / 90 A / 150 A SILVER-NICKEL BUTT CONTACTS
DNROBUST DECONTACTOR 20 A / 30 A / 50 A / 90 A / 150 A AUTOMATIC IP54/ WATER- AND DUST-TIGHT IMPACT-RESISTANT METAL CASING SUITABLE FOR HEAVY INDUSTRY The DN family of decontactors cover ratings from 30
More informationMASTERBOX Series MASTERBOX SERIES DISTRIBUTION ASSEMBLIES
MASTERBOX Series MASTERBOX SERIES DISTRIBUTION ASSEMBLIES VERSIONS They come in two sizes (WxHxD): MASTERBOX 70 x 580 x 50mm MASTERBOX 5 70 x 580 x 50mm Installation: - surface mounting - elevated with
More informationP17 combined units LIMOGES Cedex Telephone : Fax : Cat. No.(s) : 566 XX XX XX XX
8704 LIMOGES Cedex Telephone : + 33 0 06 87 87 - Fax : + 33 0 06 88 88 P17 combined units Cat. No.(s) : 66 XX - 72 XX - 77 XX - 89 XX CONTENTS Page 1. Description...1 2. Use...1 3. Range.......................
More informationFACTORY AUTOMATION. System Accessories for Mounting and Connection
FACTORY AUTOMATION System Accessories for Mounting and Connection Installing sensors simply and economically! Suitably tailored accessories for the fixing and connection of sensors offer the user enormous
More informationPractical and completely safe
FUSE RRIERS >>> Practical and completely safe Isolating fuse carriers 058 06 058 28 Dimensions (p. 0) onform to standard IE 60269-2/2. and to NF 63-2. Isolators conform to IE 60947-3. Icc: - 20 k with
More informationmore power to the cube
more power to the cube Tais Cube designed in GRP thermosetting for tough enclosure applications where space, ingress protection, quick installation and long service life is important. available with blind
More information2.3 Cable reels for industrial applications. AUTOROLLER Series ROLLER330 Series ROLLER450 Series ROLLER-BLOCK Series
. reels for industrial applications. ROLLER0 ROLLER50 ROLLER-BLOCK 60 6 reels with automatic rewind. WITH H05VV-F PVC CABLE - IP Type Metres x 6 00 00 75.00-D poles x,5 500 00 75.05-D x,5 0 000 00 75.05-D
More informationGEMÜ 549 esydrive Motorized globe valve
esydrive Motorized globe valve Features Linear or modified equal-percentage control characteristics High flow rates Force and speed are variably adjustable Extensive diagnostic facilities Operable via
More informationMicro-D MWDM-CBS Vertical Board Mount Printed Circuit Board Connector
Micro-D PB Micro-D MWDM-BS Printed ircuit Board onnector High Performance These connectors feature gold-plated TwistPin contacts for best performance. P tails are.020 inch diameter. Specify nickel-plated
More informationMTF-E. Technical features
Technical features Power supply Threephase voltage from 220V to 690V, 50Hz or 60Hz; suitable for use with a PM inverter from 20Hz to the base frequency with constant torque load profile. Polarity 2 and
More informationMULTICONTACT. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates
MULTICONTACT Number of connections up to 2000 matings. Very good resistance to vibrations. Resistance to current fluctuation. Resistance to corrosion. Solid silver-nickel contacts assure superior conductivity.
More informationSeries
PNEUMATI valves Series 79-8 - 84-85 - 87 Steelspool Valves Solenoid Valves Mechanical Valves Pneumatic Valves oils & Plug-in sockets VM/EN 4 The components illustrated and described in the present calalogue
More information20 A / 32 A / 63 A DECONTACTOR MOUNTING: SWITCH SHOULD BE ON THE UPPER SIDE!
COMPACT AND WATERTIGHT DECONTACTOR 20 A / 32 A / 63 A AUTOMATIC ip66/ip67 water- and dust-tight sealing AC-22 and ac-23 breaking capacity Impact-resistant GRP casing With sizes from 20 to 63 A, DSN decontactors
More informationSUBMERSIBLE PUMP RANGE
SUBMERSIBLE PUMP RANGE www.vegapumps.co.za INDEX VXM / VX SUBMERSIBLE PUMP... 4 PERFORMANCE DATA... 5 V RANGE SCREENED SWAGE SUBMERSIBLE PUMP... 6 PERFORMANCE DATA... 7 DIMENSIONAL DRAWING... 9 C-SERIES
More informationGEMÜ 205 Electrically operated solenoid valve
Electrically operated solenoid valve Features Hermetic separation between medium and actuator In case of power failure operation possible by manual override Standard integral optical position indicator
More informationDC2-Wire Cylindrical Long-Distance No-Polarity Proximity Switches
D-Wire ylindrical Long-Distance No-Polarity Proximity Switches FL7M Series Rigid structure reduces damage from collision with workpiece. Long sensing distance (M: mm, M: mm, M: 5 mm) D -wire switch with
More informationFor double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring
For double-acting actuators 5/ Directional Control Valves Actuation: Electromagnetic Indirect solenoid operation soft seal spool valve Connections G 1/, 1/ NPT, G 1/, NAMUR Interface Crossover-free switching
More informationSurface, flush & cable mounting Interchangeable with other manufacturers products
2011 2012 g e n e r a l c a t a l o g u e INDUSTRIL PLUGS & SOCKETS 8 INDUSTRIL PLUGS & SOCKETS Comprehensive range of Industrial Plugs, Sockets & accessories to suit all environments & applications manufactured
More informationSafety switches for hinges
Safety switches for hinges Selection diagram ACTUATORS L L6 L9 L16 FR FM FX FZ FK CONTACT BLOCKS 6 7 9 14 18 snap action 1NO+1N, make before break, shifted, close 21 4 66 NC 2NO+ 1NO+ CONDUIT ENTRIES Threaded
More informationHigh-voltage high-breaking capacity VV fuse-links
High- high- VV fuse-links [A] (ka) [mω] [W] [A 2 s] [A 2 s] 12 580 4 6,1 57 4 A 20 370 9 17,3 164 6 A 25 260 10 36 340 10 A 46 55 7 161 1 530 16 A 60 37 13 250 2 270 20 A 80 30 15 430 3 750 25 A 105 25
More informationF-Series General Specifications
arling F-Series General Specifications F-Series breakers are available up to 700, and are also available with a 25 millivolt metering shunt construction. This optional construction provides a safe method
More information1.2 Switched socket outlets with interlock
. Switched socket outlets with interlock. OMNIA Series OMNIAPLUS Series ADVANCE Series ADVANCE System ADVANCE-GRP System ADVANCE-GRP Series 8 87 Switched socket outlets with interlock. IP IP/IP7 > V
More informationConnectors Conforming to European Safety Standards
Series RoS ompliant onnectors onforming to European Safety Standards s of January 1995 all industrial machinery, including machine tools, which are exported to Europe must conform with European safety
More informationDECONTACTOR. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates
DECONTACTOR Switch with socket-outlet. The plugs and sockets as well as socket-outlet boxes and junction boxes in this range are meant for use in hazardous areas in compliance with the ATEX 2014/35/EU
More informationGEMÜ 539 esydrive Motorized globe valve
esydrive Motorized globe valve Features Linear or modified equal-percentage control characteristics High flow rates Force and speed are variably adjustable Extensive diagnostic facilities Operable via
More informationPK Industrial Plugs and Sockets. Catalogue
PK Industrial Plugs and Sockets Catalogue 2004-2005 PK industrial plugs and sockets General index PK plugs and sockets low voltage General presentation 4 Selection guide 10 Wander plugs - PK PratiKa FST
More informationFL series position switches
FL series position switches Selection diagram 0 08 0 9 0 0 0 Ball Ø. External rubber Ball Ø 8 mm, mm, stainless Glass fibre rod gasket stainless steel steel Adjustable lever Adjustable safety lever Bistable
More informationMicro-D MWDM-CBR Right Angle Thru-Hole Printed Circuit Board Connectors
Micro-D PB Micro-D MWDM-BR Printed ircuit Board onnectors High Performance These connectors feature gold-plated TwistPin contacts for best performance. P tails are.020 inch diameter. Specify nickel-plated
More informationLow and Extra-Low voltage. PratiKa. Industrial plugs and sockets. Offer panorama
Low and Extra-Low voltage PratiKa Industrial plugs and sockets Offer panorama Presentation PratiKa plugs and sockets General presentation PB102249 Additional safety is assured by sockets with electrical
More informationDescription. Features. l Grid modules clip fit to frame. without special tools. l Modules can be removed/
WIRIG DEVIES Modular Switching System mkelectric.co.uk Standards and approvals Switch modules S E 60669-1:1999 Indicator units S 5733:2010 Dimmer switches Dimmers comply with S E 60669-2-1 ccessory modules
More informationGears & Fuse Gears. IEC General Purpose Fuses NH Fuses Plastic Bases 00-EP/TP. 690V Polyester fuse bases for NH fuse-links.
-EP/TP NH fuse bases are designed for fuse-links with rated voltages up to 69 V and VD. They are in compliance with IE 669, DIN VDE 66, part, and DIN 6 (dimensions). NH fuse bases are available for delivery
More informationSRC SERIES. Signal Connectors with bayonet locking system. Derived from VG95234 & in accordance with the NF F standard
SERIES Signal Connectors with bayonet locking system Derived from VG9523 & in accordance with the NF F 61-030 standard SERIES /// SIGNAL CONNECTORS Contents Main Characteristics... 2 Synoptic...3- Synoptic:
More informationbuilding site system
building site system Anti-UV AC3 10kA >20J V0-960 C energybox The safest The most functional The most convenient ASC distribution board for construction sites energybox more functional It s the easiest
More informationWAYBOX Series. Junction boxes for galleries and tunnels
Junction boxes for galleries and tunnels > JUNCTION BOXES > REFERENCE STANDARDS EN 60670-22 Boxes and enclosures for electrical accessories for household and similar fixed electrical installations. Part
More informationControl stations and enclosures Control station enclosures : insulated, metal and flush mounting
Chrcteristics Control sttions nd enclosures Control sttion enclosures : insulted, metl nd Insulted enclosures XAP-A Mteril nd colour Glss-reinforced polyester, coloured grey throughout Approvls Specil
More informationSATRON VTe pressure transmitter
SATRON VTe pressure transmitter belongs to the series V-transmitters which will have both analog and smart properties. SATRON VTe is used for 0-4 kpa...0-00 MPa ranges. The transmitter communicates in
More informationMarina Cabinets LIMOGES Cedex Telephone: Fax:
87045 LIMOGES Cedex Telephone: 0 5 55 06 87 87 - Fax: 0 5 55 06 88 88 Marina s CONTENTS Page 1. Main characteristics...1 2. Range....1 3. Technical characteristics...1 4. Dimensions....3 5. Equipments...4
More informationBETA Switching Switches and Light Indicators
Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET
More informationMTF. Technical features
Technical features Power supply Three-phase voltage from 24V to 690V, 50Hz or 60Hz or 100-130V, 60Hz and 200-240V, 50Hz ( types are supplied without capacitor); suitable for use with an inverter from 20Hz
More informationbar -30 C C ( C for high temperature version)
Technical details ylinders > piston rod cylinders > Mini cylinders ISO 6432, double acting Operating pressure Temperature range Medium 1... 10 bar -30... +80 ( 0... +150 for high temperature version) Filtered,
More informationIEC60309 PLUGS AND SOCKETS
High performance for each condition and every environment The industrial plugs and sockets are designed to withstand highly specific operating conditions that widely vary depending in which place and situation
More informationDECONTACTOR FOR INDUSTRY 30 A/50 A/90 A/150 A/250 A/ 400 A
S EONTATOR FOR INUSTRY 30 A/50 A/90 A/150 A/250 A/ 400 A Atomatic IP54/55 Optional IP66 from 90 A Integrated load break switch: A-22 and A-23 breaking capacity hemical resistant GRP UL 94 casing p to 150
More informationSeries 20 D. Pressure switches for all-fluid technique Port sizes G 1 /4 and G 1 /2
Series 0 D Pressure switches for all-fluid technique Port sizes and Microswitch with gold-plated contacts (silver plated for outdoor variants) Plug-in connection to DIN 4650 Technical Data Fluid: Neutral
More informationImmersion temperature sensor QAE26.9.
1 790 1790P01 Immersion Temperature Sensors.. Use Acquisition of flow or return temperature in heating, ventilating, and air conditioning plants. Type summary Type Measuring range Cable length Material
More informationIntelligent Positioner
Intelligent Positioner Construction The GEMÜ 1 µpos is a digital electro-pneumatic positioner for process valve control. Designed for simple, safe and quick use with valves with strokes < mm. The positioner,
More informationControl stations and enclosures
Chrcteristics Control sttions nd enclosures Control sttion enclosures: insulted, metl nd Insulted enclosures XAP-A Mteril nd colour Glss-reinforced polyester, coloured grey throughout Approvls Specil version:
More informationDECONTACTOR FOR INDUSTRY 30 A / 50 A / 90 A / 150 A / 250 A
DECONTACTOR FOR INDUSTRY 30 A / 50 A / 90 A / 150 A / 250 A SAFE AND SIMPLE CONNECTION, EVEN AT 250 A SAFETY SHUTTER GRP OR METAL CASING The DS family of decontactors offer ratings from 30 to 250 A (ratings
More informationCHILLED WATER CONNECTION CHECKLIST AND APPROVAL. Item Notes By Date Passivation Complete Flushing Complete Nitrate corrosion Residual value:
CHILLED WATER CONNECTION CHECKLIST AND APPROVAL Passivation Complete Flushing Complete Nitrate corrosion Residual value: inhibitor added Pipe labeling complete and correct Pipe insulation in place Pipe
More informationActuators for Fire and Smoke Protection Dampers
OpenAir TM Actuators for Fire and Smoke Protection Dampers GRA126.1E/... GRA326.1E/... Electric motor driven actuators for 2-position control, nominal torque 4 Nm, with spring return to failsafe position,
More informationFor single and double operated actuators. Exhaust air recirculation (3/2 way function)
For single and double operated actuators /-, 5/- and 5/ Directional Control Valves Actuation: Electromagnetic Indirectly controlled soft seal spool valves Connection G /4 or /4 NPT NAMUR interface Exhaust
More informationInstallation. Mounting frames - TECHNICAL CHARACTERISTICS. Conformity to Standards LV Directive EN Standard
Installation Mounting frames - TECHNICAL CHARACTERISTICS Technical specifications polycarbonate (Glow Wire 850 C) dielectric strength 2000 V honeycomb structure of stiffening Conformity to Standards LV
More informationP17 Tempra Pro plugs, mobile sockets, fixed sockets, surface mounting sockets and appliance inlets - IP 66/67-63 A A
CONTENTS Page 5 555 09 5 555 29 5 555 59 5 555 9 1. General characteristics...1 2. Use...1 3. Range/Equivalence table...2 4. Dimensions..............................3 5. Technical characteristics...5 6.
More informationHigh-voltage high-breaking capacity VV fuse-links
High- high- VV fuse-links imum cold resistance power dissipation pre-arcing I t value total I t value [kv] (mm) I n [A] (ka) [mω] [W] [A s] [A s] 1 580,1 57 A 0 370 9 17,3 1 A 5 00 10 3 30 10 A 55 7 11
More information