ADVANCE GRP Series 125A Switched Interlocked socket outlets
|
|
- Ross Kelley
- 6 years ago
- Views:
Transcription
1 DVNCE GRP Series 125 Switched Interlocked socket outlets
2 DVNCE GRP Series 125 > SWITCHED INTERLOCKED SOCKET OUTLETS > REFERENCE STNDRDS EN Plugs, socket outlets and couples for industrial purposes. Part 1: general requirements. EN Plugs, socket outlets and couples for industrial purposes. Part 2: dimensional interchangeability requirements for pin and contact-tube accessories of harmonised configurations. EN Plugs, socket-outlets and couplers for industrial purposes. Part 4: Switched socket-outlets and connectors with or without interlock. > VERSIONS WITH MECHNICL INTERLOCK With switch-disconnector IEC / EN Electrical apparatus for use in the presence of combustible dust. Part 0: General requirements. With switch-disconnector and fuse IEC / EN Electrical apparatus for use in the presence of combustible dust. Part 1: Protection by enclosures 'td'. With fuse and switch With molded case circuit breaker with thermal magnetic trip unit > PRODUCTS FOR USE IN POTENTILY EXPLOSIVE ENVIRONMENT Scame offers products suitable for installation into environments under potential risk of explosion identified as Zone 22 and that enter into the field of application for the TEX Directive (European Directive 94/9/CE). With molded case circuit breaker with thermal magnetic and residual current release trip units > VERSIONS WITH ELECTRICL INTERLOCK With contactor 2
3 > BEHVIOUR WITH CHEMICL ND TMOSPHERIC GENTS Saline solution Resistant Limited Resistance cids Resistant Not Resistant Bases Concentrated Diluted Concentrated Diluted Hexane Benzol cetone lcohol Resistant For specific substances please contact our technical service > TECHNICL CHRCTERISTICS > EX CLSSIFICTION Rated current: 125 Rated voltage: V~ Frequency: 50 60Hz Insulating voltage: 500/690V~ Protection degree: IP66 Operating temperature according to the reference standard: -25 C+40 C Max. operating temperature: 60 C Self-extinguishing GW test: 850 C/960 C Self-extinguishing UL94: V0 Material: Thermoset IK degree at 20 C: IK10 Cable inlets: Top side max 3xM63 Bottom side max 2xM63 Switch-disconnectors: BB OT 160 Fuse: NH00 Thermal magnetic protection: Molded case circuit breaker BB Tmax T1B (16k) with thermal magnetic trip unit TMD (adjustable thermal threshold 0,7 1 x In fixed magnetic threshold 10 x In) Thermal-magnetic and Molded case circuit breaker residual current protection: BB Tmax T1B (16k) with thermal magnetic trip unit TMD (adjustable thermal threshold 0,7 1 x In fixed magnetic threshold 10 x In) + residual current release trip units RC221/1 (adjustable residual current trip 0,03-0,1-3 and time limit for non-trip instantaneous) Version with contactor: Contactor CL09 GE POWER CONTROL Colour: Grey RL7037 Limited Resistance Limited Resistance Solvents Via Costa Erta 15 Parre BG ITLY 3P+N h / V~ C o d F S C M E T E X 0 2 E x t D 2 2 I I 3 D I P 6 6 T 9 0 C D O N O T O P E N W H E N E N E R G I Z E D I N P R E S E N C E O F E X P L O S I V E T M O S P H E R E Rated current () Limited Resistance Socket outlets Min Limited Resistance Max Mineral oil Resistant tex Code: II 3D Ex Protection type: Ex td 22 IP66 T90 C Operating Temperature Range: -25 C +60 C Maximum permissible surface temperature: T90 C Switched socket outlets with interlock degree of Protection: IP66 Plugs - degree of Protection: IP66/IP67 Impact Resistance: 7J Switched socket outlets with interlock material: Thermoset Plugs material: Thermoplastic Interlocked switch sockets outlets CE certificate: SCME TEX 02 Plugs CE certificate: SCME TEX 03 > WIRING OPERTIONS Wiring capacity of the terminals (mm 2 ) Min Plugs UV rays Resistant Max DVNCE GRP Series
4 DVNCE GRP Series 125 > PPLICTION EXMPLES 4
5 > TECHNICL DT SWITCH DISCONNECTORS Rated insulation voltage Ui Rated impulse withstand voltage Uimp Thermal current Ith Thermal current Ithe Nominal current rating Ie C21 C22 C23 C3 Resistite loads, inluding moderate overloads Mixed resistite and inductive loads, including moderate overloads Switching off motor loads or other highly inductive loads (3 phase/3 pole) Squirrel-cage motor: starting, switching off motor during running (3 phase/ 3 pole) 400V 500V 690V 400V 500V 690V 400V 500V 690V 400V 690V Vac Vdc kv DVNCE GRP Series 125 DC21 Resistite loads, including Moderate overloads 300V 160(*) DC22 Mixed resistite and inductive loads, including moderate overloads 250V 600V 160(*) - Rated short-time withstand current Icw (s) 4000 Conditional short-circuit current k 24 Short-circuit protection ssociate fuse size for conditional short-circuit current - Type gg Rated short-circuit making capacity Icm 500V k k Rated current UL General applications - Single-phase and Three-phase C motor, all-pole interruption - Single-phase C motor, B, C, D, all-pole interruption - Three-phase 600V V 240V 240V 480V 600V Hp Hp Hp Hp Hp 7, Permissible wire range Wire mm 2 WG /10 (*) 2+2 poles in series 5
6 DVNCE GRP Series 125 Outdoor wall fastening mple space for easy wiring Under-plate cable runway Switchdisconnector with mechanical lock that can be accessorized with auxiliary contacts Threaded metal inserts Punched marks for easy closure of the cover Easily extractable bottom plate Possibility to assemble microswitch BOTTOM VIEW TOP VIEW Module in hightemperature glassfibre filled engineering polymer Possible entry from bottom side (input-output also) 6 Self-centering punch marks to facilitate drilling
7 Single-piece waterproof gasket Rating on metal plate Captive stainless steel closing screws Lockable Switch in position 0 and 1 DVNCE GRP Series 125 Double mechanical lock and metal levers High-strength material with superior UV and chemical resistance Residual current release trip units test push button Cover entirely separate from the base for easy installation n electronic device controls the status of the interlocked socket, monitoring the electrical functionality: - operation of the signalling and control card is guaranteed even when the load is not connected; - indicates that the fuses are not open and all the phases are present (indicator light on); - indicates that the socket outlet is powered correctly (indicator light on); - signals the interruption of one or more fuses (indicator light flashing); - signals the absence of a phase (indicator light flashing)*; - indicates that the socket outlet is not powered (indicator light off). * for single-phase products in the event of phase/ neutral loss LED signaling appears off. 7
8 DVNCE GRP Series 125 > MECHNICLLY INTERLOCKED SOCKET OUTLETS - IP66 Plug Hz Volt Colour h 2P+E / V P+E / V P+N+E / V Plug Hz Volt Colour h Switchdisconnector Switchdisconnector and fuse (*) 2P+E / V F 3P+E / V F 3P+N+E / V F Plug Hz Volt Colour h Fuse (*) and switch 2P+E / V FS 3P+E / V FS 3P+N+E / V FS Molded case circuit breaker with thermal magnetic trip unit Plug Hz Volt Colour h 2P+E / V M 3P+E / V M 3P+N+E / V M 8 Molded case circuit breaker with thermal magnetic and residual current release trip units Plug Hz Volt Colour h 2P+E / V RM 3P+E / V RM 3P+N+E / V RM (*) Fuses not included Pack Quantity.
9 > ELECTRICLLY INTERLOCKED SOCKET OUTLETS - IP66 Contactor (*) Plug 2P+E / V T 3P+E / V T 3P+N+E / V T (*) Microswitch already provided. Contactor operated by microswitch. Hz Volt Colour h DVNCE GRP Series 125 > CCESSORIES Terminals Contacts Microswitch kit 400V 10 (microswitch + terminal block) 1NO+1NC 4x4 mm For products with mechanical interlock. > COMPLEMENTRY PRODUCTS - OPTIM-EX SERIES - PLUGS IP66/IP67 Plug Hz Volt Colour h Plugs 2P+E / V EX P+E / V EX P+N+E / V EX
10 DVNCE GRP Series 125 > DIMENSIONS (Dimensions in mm) 10
11 Switch-disconnector Switch-disconnector and fuse Fuse and switch DVNCE GRP Series 125 Molded case circuit breaker with thermal magnetic trip unit Molded case circuit breaker with thermal magnetic and residual current release trip units Contactor (Dimensions in mm) 11
12 ZP00738-GB-2 ScameOnLine SCME PRRE S.p.. VI COST ERT, PRRE (BG) ITLY TEL FX
TechData. Master data. P/N: SCM460MI7W INTERLOCK SOCKET 3P+E IP67 60A 7h **Supplied with base
ddendum 1/11/1 rticle Picture P/N: SCM0MI7W INTERLOCK SOCKET P+E IP7 0 7h **Supplied with base 79.0 P/N SCM0MI7WNB INTERLOCK SOCKET P+E IP7 0 7h **No base supplied. Select base below. Base Options: Single:
More informationIS OL ATOR S S E RIE S. Enclosed change-over switches I/O/II
IS OL TOR S S E RIE S Enclosed changeover switches I/O/II ISOLTORS Series ENCLOSED CHNGEOVER SWITCHES I/O/II, 0 1 Poles IP degree IP65(*) 1/5 IP65(*) 1/5 IP65(*) 1/5 IP65(*) 1 IP65(*) 1 THERMOPLSTIC LUMINIUM
More informationCOMMAND Series. Switching-disconnectors units
COMMND Series Switchingdisconnectors units COMMND Series > ROTRY SWITCHES > REFERENCE STNDRDS EN 6097 Low voltage switchgear and controlgear. Part : switches disconnectors, switchdisconnectors and fusecombination
More informationADVANCE- GRP S YS TEM. Switched Interlocked socket outlets [ ]
DVNCE GRP S YS TEM Switched Interlocked socket outlets DVNCEGRP System SWITCHED INTERLOCKED SOCKET OUTLETS 63263 REFERENCE STNDRDS EN 60309 Plugs, socket outlets and couplers for industrial purposes. Part
More information70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX
70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX SWITCH DISCONNECTORS IN METAL BOX ATEX SWITCH DISCONNECTORS IN METAL BOX The switch disconnectors in plastic boxes, which are available in control or emergency
More informationIS OL ATORS-EX S ERIES
IS OL ATORS-EX S ERIES Switch disconnectors for applications in potentially explosive atmospheres - DUST [ ] II 2D [ II 2D] SWITCHES DISCONNECTORS REFERENCE STANDARDS EN 60079-0 Electrical apparatus for
More information1.2 Switched socket outlets with interlock
. Switched socket outlets with interlock. OMNIA Series OMNIAPLUS Series ADVANCE Series ADVANCE System ADVANCE-GRP System ADVANCE-GRP Series 8 87 Switched socket outlets with interlock. IP IP/IP7 > V
More informationUNIBOX Series Enclosure and wiring accessories IP40-IP55
UNIBOX Series Enclosure and wiring accessories IP-IP55 UNIBOX Series > ENCLOSURE FOR WIRING ACCESSORIES > REFERENCE STANDARDS EN 60670-1 Boxes and enclosures for electrical accessories for household and
More informationADVANCE- GRP[ GD] S ERIES OP TIMA- EX[ GD] S ERIES
ADVANCE GRP[ GD] S ERIES OP TIMA EX[ GD] S ERIES Plug and socket for applications in potentially explosive atmospheres GAS & DUST [ ATEXIECEx ] II 2GD ADVANCEGRP[GD] Series OPTIMAEX[GD] Seriesimbro ATEXIECEx
More informationCombination Units. Combination Units do not present on this catalogue are available on request.
Combination Units Combination Units Prewired combination units 11 unswitched or switchinterlocked with RCD, MCB or RCBO protection as standard. Multioutlet combination units unswitched with RCD, MCB or
More informationELECTRICAL CHARACTERISTICS. Permissible overload (A) 22 > transformer 42 > > > > >
IEC 309 TS New range of plugs and socket-outlets meeting the dimensional, construction/performance and safety requisites defined by the international Standards IEC 60309-1 and IEC 60309-2, subsequently
More information67 IB INTERLOCKED SOCKET-OUTLET IEC 309 STANDARDS
Technical data and compliance with Standards Component Interlocked switched socket-outlets SELV socket-outlet Rotary switch MT60 miniature circuit breaker, C characteristic, 6kA Reference Standards EN
More informationSAFETY SWITCHES / ISOLATORS A TECHNICAL DATA
ENCLOSED SWITCHES SAFETY SWITCHES / ISOLATORS 16-800A TECHNICAL DATA Safety switches / isolators 10A 16A 25A 40A 63A 80A 125A 160A 200A 250A 315A 400A 630A 800A Rated Insulation voltage Ui (V) 690 690
More informationRated current In (A) Other electrical data. IEC 309 range. EN see 70 RT range IK
44 and 67 IB standard horizontal and vertical socket-outlets Industrial-type socket-outlets conforming to IEC 309 Standard, with mechanical interlock consisting of a circuit breaker enabling the plug to
More informationRotary limit switches FCR FGR series
Rotary limit switches FCR FGR series Rotary control switches with 00mm rods from up to positions. Control switches with rotary gear from up to 00 rpm with or micro switches. 0 Rotary limit switches FCR
More informationcor Long Run Experience
Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30
More informationVoltage/ Color Coding. 3ø480. 3ø250. 3ø600. 3øY277/408. 3øY120/208. 3øY347/600
ADVANCE-RP System A 60 Poles & Wires P W P W P 4W P 4W P 4W Receptacle/ Connector Configuration Plug/ Inlet Clock position 6h 7h 7h 9h h Voltage/ Color Coding 0 40 ø40 ø0 ø600 With base SCM60MI6W SCM60MI7W
More informationKATKO Safety Switches:
KATKO Safety Switches: Reliability, Economy, Safety KATKO/2007.01/AL 1 KUM 16-25A Dimensions: Overall: 130,4 x 96,4 x 42,0 Mounting holes: 118,0 x 84,0 -Polycarbonate or ABS IP65 enclosure -Excellent UV
More informationPRODUCTS FOR W INERIES. Products for the wine-making industry
PRODUCTS FOR W INERIES Products for the winemaking industry Products for wineries INDEX ISOLTORSHD Series Nonfusible motor disconnect switches pg.16 2 EUREKHD Series Pin and sleeve devices pg. DVNCEGRP
More informationMCCB Accessories to suit AF
MCCB s MCCB Accessories to suit 125-630AF Accessory fitting combinations INTERNAL General purpose types Micro-switch types Auxiliary Heavy duty types Bridge -contact types Auxiliary Shunt UVT Internal
More informationXCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx
Characteristics limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx Main Range of product OsiSense ATEX D Series name Standard format Product or component type Limit switch Device short name XCKJ
More informationSD Series Non-Fused Load Switches
SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load
More informationLOAD BREAK SWITCHES & SWITCH FUSES
LOD BREK SWITCHES & SWITCH FUSES Switch Fuses FSF FSF 250 FSF FSF 60 Load Break Switches FLS FLS 250 FLS FLS 60 CONTENTS General Information bout Load Break Switches & Switch Fuses Technical Characteristic
More informationDPX moulded case circuit breakers
BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.
More informationMSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3
Introducing the New WEG Series. The was developed according to IEC 60947-3 & UL508. The compact, reliable design of the allows the operator to safely disconnect power and isolate the circuit within the
More informationSafety Performance WORLD PREMIERE. palazzoli.com 1
Safety Performance WORLD PREMIERE palazzoli.com 1 The inventions that progressed our life Benjamin Franklin Energy and persistence conquer all things. The lightning rod 2 The inventions that progressed
More informationContact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE
Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe
More informationSwitch Disconnectors
Switch Disconnectors Reversible terminals allow the same switch body to be used in both front & rear mount applications 25A - 32A - 50A - 63A - 80A - A versions available Neutral pole, additional poles
More informationswitch disconnectors switch disconnectors fuses
SWITCHGER R switch disconnectors RB switch disconnectors fuses R switch disconnectors and RB switch disconnectors fuses are designed for distribution of electricity, making and breaking currents and protection
More informationDOMINO Series IP40. Surface and flush mounting consumer units
DOMINO Series IP40 Surface and flush mounting consumer units DOMINO Series DOMINO SERIES CONSUMER UNITS AND ENCLOSURES DOMINO Series consumer units are characterised by their modularity and the ease with
More informationProducts for. Section
2 Products for Section Chemical Industries Grain silos Oil and Gas industry Plastics Fertilisers and insecticides Wood Cosmetics and perfumes lcohol and spirits Pharmaceutical Industries, etc. 90 2005-2006
More informationPermissible overload. 22 A > A Hz > Hz 42 A > A. Heat resistance
IEC 309 HP technical characteristics New range of plugs and socket-outlets meeting the dimensional, construction/performance and safety requisites defined by the international Standards IEC 60309-1 and
More informationSIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.
Transfer switches svr_151_a The solution for > Manufacturing > Power distribution SIRCOVER 250 Strong points svr_214_a > Complete range > Easy to connect > Stable positions > On-load switching Conformity
More informationOverview of Low voltage equipment - Moulded-case & Air circuit-breakers
Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are
More informationATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A
ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat
More informationSwitches disconnectors with fuse-holders. XNF series TF series
Switches disconnectors with fuse-holders XNF series TF series Quick Reference Switch-disconnectors with fuse-holders XNF series TF series XNF Series page 155 16 32A with fuse holders 3 4 Pole Auxiliary
More informationLimit Switch - Prewired Type Metal Body
Limit Switch - Prewired Type Metal Body Sealed with epoxy resin al the base of the box Degree of protection IP67 Thermoplastic material or diecast zinc alloy body Positive Opening Operation Minimum Actuation
More informationINDUSTRIAL PLUGS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates
INDUSTRIAL PLUGS A range from 16 A to 600 A 1000 V. Automatic watertightness from IP44 to 66/67. From -40 to +240 C. GRP or metal casing. Reliable & compact. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com
More informationXACA871 pendant control station XAC-A - 8 pushbuttons
Characteristics pendant control station XAC-A - 8 pushbuttons Main Range of product Product or component type Device short name Complementary Control station type Enclosure material Electrical circuit
More informationSENTRON Switching and Protection Devices Switch Disconnectors
SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP
More informationEX-REPAIR AND MAINTENANCE RECEPTACLES
EX-REPAIR AND MAINTENANCE RECEPTACLES A 3 A plugs and receptacles plastic version for zones, 2, 2 and 22 For maintenance, repair and upgrading work, appliances such as drills, welding transformers, hand
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationIEC 309 RANGE PLUGS AND SOCKETS TO IEC 309 STANDARDS
IC 309 RNG PLUGS ND SOCKTS TO IC 309 STNDRDS TCHNICL CHRCTRISTICS 1 SL / 3 SL - RPID SSMLY ND WIRING PLUGS ND SOCKTS RFRNC STNDRDS The IC 309 SL industrial plugs and sockets meets the dimensional, construction-performance
More informationMicroswitches MK series
Microswitches MK series Microswitches of MK series have been developed in order to add new features to traditional and tested microswitches of Pizzato Elettrica. These products have been designed with
More informationWAYBOX Series. Junction boxes for galleries and tunnels
Junction boxes for galleries and tunnels > JUNCTION BOXES > REFERENCE STANDARDS EN 60670-22 Boxes and enclosures for electrical accessories for household and similar fixed electrical installations. Part
More informationPY, SPY; FSQC, FP; EPC; AP
Ex d PY, SPY; FSQC, FP; EPC; AP Sockets and plugs Aluminium alloy with low copper - Group IIC content - Zone 1, 2, 21, 22 - Aluminium alloy - Ergonomic - Plugs can be used with industrial sockets Polyester
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 250
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.
More informationMicroswitches MK series
D Microswitches MK series Introduction Microswitches of MK series have been developed in order to add new features to traditional and tested microswitches of Pizzato Elettrica (cross-reference at page
More informationLimit Switches - Limit Type Plastic Body IP65
Limit Switches - Limit Type Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque Minimum
More informationManual Motor Starters. Meta-MEC
Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters
More informationDMX 3 -I 2500 switch disconnectors
8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40
More informationGV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features
Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator
More informationB115...B180 RF200 RFN200 B250...B400 RF400 RFN400
Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 160
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY
More informationSIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC
and Manual Changeover Switches BY-PSS appli_114_a svr_099_b_1_cat svr_059_a_1_cat Changeover switches with fully visualised breaking from 125 to 3200 Function products are manually operated multipolar
More informationProtectors. 35mm DIN rail snap-on mounting. Wide range of accessories
Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified
More informationAF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationProducts and solutions for photovoltaic applications
Products and solutions for photovoltaic applications Components for string and interface control panels Switch disconnectors Surge protection devices Fuse holders The range of LOVATO Electric components
More informationM-0. M-0... series control, monitoring and signalling devices. Ex e
M-0 The new Cortem M-0 series control, monitoring and signalling devices are installed as external accessories on '' enclosures and boards used in any industrial environment where an explosive atmosphere
More information6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate
More informationSIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A
Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability
More informationSafety switches with separate actuator
Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 ACTUATORS VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 FR FX FK FW 5 6 7 11 1 14 NC NC slow action slow
More informationSIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC
Load break switches sircopv_058_a cat SIRCO PV UL98 from 00 to 2000 up to 500 VDC sircopv_059_a cat Strong points > Patented switching technology. > Positive break indication. > Up to 000 VDC as per characteristics
More informationLoad break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...
Load break switches Load break switches for all your applications.................................... Why choose a load break switch designed for photovoltaic applications?............. Load break switch
More informationXACA871 pendant control station XAC-A - 8 pushbuttons
Characteristics pendant control station XAC-A - 8 pushbuttons Complementary Control station colour Connections - terminals Mechanical durability Cable entry Contact code designation [Ithe] conventional
More informationNB1 Miniature Circuit Breaker
P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide
More informationS&S POWER SWITCHGEAR EQUIPMENT LTD.,
S&S POWER SWITCHGEAR EQUIPMENT LTD., Works: No.4, EVR Street, Sederapet, Puducherry 605 111, India. Corporate Office: Plot No:14, CMDA Industrial Area-II, Chithamanur Village, Maraimalai Nagar-603209,
More informationSwitches with manual reset
Switches with manual reset Selection diagram 01-W 02-W 05-W 0-W -W -H0W 16-W 16-H0W Ø mm roller Ø mm roller Ø mm roller Ø mm roller 0-W 1-W 51-W 52-W 5-W 55-W -W adjustable lever safety adjustable lever
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More informationDPX earth leakage DPX 3 -I earth leakage
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.
More informationIndustrial Protection Products Edition
Industrial Protection Products 2016 Edition COMPANY PROFILE Shanghai Liangxin Electrical Co., LTD. one of the leading low-voltage electrical component manufacture in the high-end market, was established
More information125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request
125 to 4000 A sirco_353_a_1_cat sirco_296_a_1_cat sirco_300_b switches are manually operated or motorised multipolar load break switches. They break on and off under load and provide safety isolation for
More informationfuses fuse holders CYLINDRICAL
fuses fuse holders 02 gg FUSES 04 am FUSES FUSES 09 PMC COMPACT 09 -CC FOR CC CLASS FUSE-LINKS 11 PMB PLUG CONNECTION 11 CLIP CONTACT FOR φ10 FUSE-LINKS 10 PMF 11 BAC OPEN FUSE BASES 06 gg FUSES FUSES
More informationUNION-EX Series Cable glands and accessories for applications in potentially explosive atmospheres
UNION-EX Series Cable glands and accessories for applications in potentially explosive atmospheres UNION-EX Series > METAL CABLE GLANDS (by RCN) > REFERENCE STANDARDS EN 61241-0 Electrical apparatus for
More informationHEAVY-DUTY PLUGS & SOCKETS
HEAVY-DUTY PLUGS & SOCKETS 315 A/400 A/500 A/600 A Up to 600 A/1 000 V Automatic IP66/IP67 water-and dust-tight Mechanical and electrical interlocking Up to 6 auxiliary and 2 pilot contacts Marine aluminum
More informationAF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals
AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.
More informationELECTRICAL CHARACTERISTICS. Permissible overload (A) 22 > transformer 42 > > > > >
New range of plugs and socket-outlets meeting the dimensional, construction/performance and safety requisites defined by the international Standards IE 60309-1 and IE 60309-2, subsequently assimilated
More informationPlug and Socket Devices SolConeX 16 A Series 8570
Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control
More informationVistop TM isolating switches 63 to 160A
DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary
More informationSFS-UFS Single Foot Switches
SFS-UFS Single Foot Switches Technopolymer housing, shock proof Protection degree IP53 or IP65 13 contact blocks available Various auxiliary devices available UFS Series SFS Series Options & Ordering Codes
More informationJunction boxes for control, monitoring and control panel Ex tb
Junction boxes for control, monitoring and control panel - Zone 21, 22 - Category 2D - Aluminium, reinforced polyester or stainless steel enclosures - Standard or custom products Inspection window Padlockable
More informationTO ALL OUR CUSTOMERS. Poles
Page 1 TO ALL OUR CUSTOMERS 1. NEWS: NEW 20-32-40A THERMOPLASTIC ENCLOSURES FOR THE ISOLATORS SERIES The thermoplastic ISOLATORS series offer has been expanded, introducing a range of products for 20,
More informationPage. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases
Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar
More informationEASIGO Series INDUSTRIAL PLUGS AND SOCKETS TO BS REFERENCE STANDARDS BS 196: Industrial Plugs & Sockets BS196 FITTINGS (5-30 AMPERES)
ESIGO Series INDUSTRIL PLUGS ND TO BS9-9 REFERENCE STNDRDS BS 9: 9 Industrial Plugs & Sockets BS9 FITTINGS (5-0 MPERES) In90, BS9 was issued as the first British Standard covering industrial plugs and
More informationCylindrical fuse-link
Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH
More informationContactor Types CI 61-98
MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories
More informationDOMINO Series surface mounting IP55
Series surface mounting IP55 SERIES CONSUMER UNITS SURFACE MOUNTING VERSION - IP55 REFERENCE STANDARDS International standard IEC 60670 (989) and the Modification (994) Part : General requirements for
More informationC -5 to +55 (0.8 to 1.1Uc) Permissible o
T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC 60947-4
More informationAF09... AF30 3-pole Contactors up to 25 HP / 600 VAC
AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24
More informationK50H004UP cam changeover switch - 4-pole A - screw mounting
Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A
Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated
More informationT-Switches Range. TL Contactors TS disconnectors TP Contactors. TELARC s multipurpose DC and AC current switches for multiple application.
TP-PNORM T-Switches Range TL Contactors TS disconnectors TP Contactors TELRC s multipurpose DC and C current switches for multiple application Rolling Stock Energy generation Substation equipment Industrial
More informationSWITCHGEAR. 4G cam switches
SWITCHGEAR 178 4G cam switches ENERGY SAFELY SWITCHED 179 SWITCHGEAR 180 GENERAL INFORMATION 4G-series cam switches are low voltage switches, designed according to the latest knowledge about switchgear
More informationFUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A
Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong
More informationIndustrial Contactors CTX 3 3P 185A - 800A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...
More informationSafety Switches Series 8537
Safety Switches www.stahl.de > 3- and 6-pole switches 12 / 16, 25, 40, 63 / 80, 125 / 160, 250, 315, 400, 500 A > Motor switching capacity AC-3 and AC-23 acc. to IEC 60947-3, EN 60947, DIN VDE 0660 part
More informationATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A
TyS t M - TyS g M utomatic Transfer Switching Equipment Transfer switches new The solution for > High Rise uildings > Data centre > Healthcare buildings TyS g M I-0-II P atys-mg_001_b_1_cat Function TyS
More informationmore power to the cube
more power to the cube Tais Cube designed in GRP thermosetting for tough enclosure applications where space, ingress protection, quick installation and long service life is important. available with blind
More informationThermal Overload Relays
Data Sheet Thermal Overload Relays Ex9RD Series Ex9RD93 Ex9RD25 www.noarkusa.com NOARK Ex9RD Series Thermal overload relays are economic electromechanical protection devices for the main circuit. They
More information