1.2 Switched socket outlets with interlock

Size: px
Start display at page:

Download "1.2 Switched socket outlets with interlock"

Transcription

1 . Switched socket outlets with interlock. OMNIA Series OMNIAPLUS Series ADVANCE Series ADVANCE System ADVANCE-GRP System ADVANCE-GRP Series 8 87

2 Switched socket outlets with interlock. IP IP/IP7 > V < V > V < V OMNIA Series ADVANCE Series OMNIA Series ADVANCE Series OMNIA Series ADVANCE Series ADVANCE GRP Series OMNIA Series ADVANCE Series ADVANCE GRP Series Flush mounting With fuse holder page 9 page 9 Without fuse holder Without base With fuse holder page 9 page 9 page 9 page page 9 page 0 Without fuse holder page With fuse holder page 9 page 0 page 95 page 05 page 8 page Surface mounting Without fuse holder page 9 page 0 page 97 page 8 page 95 page 0 page 8 page 97 page With DIN RAIL ( modules) page 0 page 8 page 07 page

3 OMNIAPLUS System Interlocked socket for domestic use. FLUSH MOUNTING - IP5 OMNIAPLUS Series ACCESSORIES Standard WITHOUT PROTECTION Italian P7/ A - P+E / i Italian P0 A - P+E / i Pluristandard A - P+E / French A - P+E / German Unshuttered A - P+E / German Shuttered A - P+E / British A - P+E / New Zealand 0A - P+E / Swiss 0A - P+E / South African A - P+E / Indian /A - P+E / FUSE.x MCB RCBO Surface mounting box IP7 PG Cable Inlet i METRICA Cable Inlet 57.M00 Flush mounting box IP55 i Flame complete with gasket i from page 7 Flange x5 (*) 0A, C0 OMNIAPLUS Series DOMOPLUS Series Automatic spring closure Lockable door knob with blocking in position 0 and Application examples OMNIA Series Cover in darkened polycarbonate in order to see inside Version without protection, with fuse protection, MCB, RCBO (insert EVOLUTION Series) Maintains the IP5 degree of protection with the plug inserted With P+N blocking switch Stainless steel screws, unlosable MBOX Series OMNIA Series ADVANCE Series DOMINO Series ITALIAN STANDARD P7/-A Shuttered socket CEI - ITALIAN STANDARD P0-A Shuttered socket CEI - PLURISTANDARD A Shuttered socket FRENCH STANDARD A Shuttered socket GERMAN STANDARD A BRITISH STANDARD SOCKET A Shuttered socket - NEW ZEALAND 0A Unshuttered socket AS/N5 SWISS STANDARD 0A Unshuttered socket SEV 0:998 SOUTH AFRICAN A Shuttered socket SANS : (00) INDIAN STANDARD /A Shuttered socket IS 9:

4 switched socket outlets with interlock >V. FLUSH MOUNTING OMNIA Series (Δ) (Δ) OMNIA Series 0. (Δ) Poles Hz. Volt Colour h. IP - WITHOUT FUSE HOLDER IP - WITH FUSE HOLDER IP/IP7 - WITHOUT FUSE HOLDER IP/IP7 - WITH FUSE HOLDER A A A A A / / / P+E / /0 trasf. >00-0 () > c.c. () >- c.c. () > / / / P+E / /0 () () > >00-0 () > / / / P+N+E / /0 () >00-0 () > Rated voltage >V - Approvals: from page 5 - Switches as spare parts: page 88 - Supplied with stainless steel fixing screws. () The maximum amount of current available, taking into account the maximum overheating temperature allowed by the relevant standards, must be downgraded with respect to the nominal current by 5% for products with frequencies ranging above 00 Hz; contact Scame Technical Service for further information. () When using DC we recommend that you make sure of implementing the protection scheme that is most suitable for the system involved; contact Scame Technical Service for further information. () Pay special attention when selecting the appropriate fuse with respect to the tension of the installation. From page 98 (Δ) Products must be installed together with their required components (Ex. wall box 57.M008). It is downgraded to IP55 when fitted to a sufficiently rigid board. 9 9

5 switched socket outlets with interlock >V. SURFACE MOUNTING 0. ( ) OMNIA Series. 5. ( ) OMNIA Series ( ). Poles Hz. Volt Colour h. IP - WITHOUT FUSE HOLDER A IP - WITH FUSE HOLDER A ( ) ( ) A IP/IP7 - WITHOUT FUSE HOLDER A A ( ) IP/IP7 - WITH FUSE HOLDER ( ) / M M70.70.M70 / M M8.8.M8 / P+E / /0 trasf. >00-0 () > c.c. () >- c.c. () > M M78 5.M8 5.M8.78.M / M M7.7.M7 / M M7.7.M7 / M M8.8.M M85.85 P+E / M8.8 /0 () () > M >00-0 () > / M M79.79.M79 / M M75.75.M75 / M M87.87.M87 P+N+E / /0 () M87 5.M >00-0 () > M Rated voltage >V - Approvals: from page 5 - Switches as spare parts: page 88 - Supplied with stainless steel fixing screws. () The maximum amount of current available, taking into account the maximum overheating temperature allowed by the relevant standards, must be downgraded with respect to the nominal current by 5% for products with frequencies ranging above 00 Hz; contact Scame Technical Service for further information. () When using DC we recommend that you make sure of implementing the protection scheme that is most suitable for the system involved; contact Scame Technical Service for further information. ( ) The OMNIA Series surface mouting are also avilable in a metric cable inlet. For ordering add M after the first three digits (ex. 0.M70). ( ) Articoli disponibili solo con entrata cavi metrica e involucro rialzato. Note: in ADVANCE System, use version with METRIC cable inlet. From page 98 ADVANCE System From page

6 switched socket outlets with interlock <V. FLUSH MOUNTING OMNIA Series SURFACE MOUNTING ( ) Rated Rated Socket Type Colour h voltage IP IP/IP7 Socket Type Colour h voltage IP IP/IP7 With transformer P-A Normal - 0-5V~ (*)() - 0-5V~ P-A Normal Without 0-V~ transformer () - 0-5V~ P- Normal 0-V~ OMNIA Series - 0-5V~ P-A Normal Without 0-V~ transformer () - 0-5V~ P- Normal 0-V~ ( ) Rated operating voltage <V - Approvals: from page 5 - When the plug is inserted a micro-switch turns on that closes the circuits () SELV transformer g 0/V~ 0VA ( continuous duty). () The versions without transformer are particularly suitable for installations with centralised extra-low voltage transformer. ( ) The OMNIA Series surface mounting are also available in a metric cable inlet. Add M after the first three digits (ex. 0.M0). (*) Unsuitable for and 57.M00 boxes. ADVANCE System, DOMINO IP and MBOX enclosures. Note: in ADVANCE System, use version with metric cable inlet. From page 98 ADVANCE System From page

7 Modular system. FLUSH MOUNTING BOX Flush mounting box 0x8x7 i Flush mounting box for plasterboard walls Suited for being walled up in buried systems. - Complete with coupling insert. FRAME Dimensions Dimensions Flame complete with gasket 7xx9 IP55 (*) i Coupling insert (*) When assembled together with the relevant component. - For the installation of flush mounting boxes (product ). EQUIPMENT ENCLOSURE SURFACE MOUNTING SYSTEM - IP7(*) box kit Consumer unit system Dimensions DIN Modules DIN OMNIA x75x89 A - METRIC 57.M008 0x8x7-0W ( ) Cable inlet (*) When assembled together with the relevant component. ( ) When joined with consumer unit (product page 00 ). calculated conforming to CEI -9 italian standards. - Except fuse versions. - Not suitable for items 00. and 05.. SURFACE MOUNTING SYSTEM - IP(*) Dimensions PG i METRIC 57.M00 Dissipation x7x W i 57.0 xx W i 57.0 DIN 87x08x W i Blind Consumer unit DIN with terminal block opening 57.0 Enclosure for OMNIA Series socket outlets / (*) They can be fitted into the MBOX5 enclosures. (*) Hole Ø 0.5 mm on the upper side. Blank plate system DIN Modules Dimensions Dissipation - x7x - i xx - i x08x - i 57.0 (*) When assembled together with relevant component. ( ) calculated conforming to CEI -9 italian standards

8 Modular system. CONSUMER UNIT ASSEMBLY KIT - IP55(*) Dimensions BLANK PLATE - IP7(*) (*) When assembled together with the relevant component. ( ) When joined with surface mounting box (product 57.00). calculated in conformity to the CEI -9 standards. - DIN modules and supports included. - Installation in the flush mounting box through the frame item Complete with locking knob, triangular locking key and stainless steel fixing screws. - The consumer unit can also be installed in the IP DOMINO Series surface mounting anclosures. DIN modules x5x5 0W ( ) i PROTECTION COVER - IP0 Dimensions cover kit x98x For panel mounting of OMNIA Series interlocked switch sockets outlets without fuse carrier. - Top and bottom cable entries. - Supplied with fixing screws. COVER WITH INSERT FOR MODULAR DOMESTIC ACCESSORIES ONLY - IP55 Flange Flange x5mm Flange x5mm Dimensions Pre-holing x5x5 No i 5.00 x5x5 A (70x87mm) i 5.05 Enclosure for modules: Living International, Luna, Light and Light Tech x5 5.0( ) Enclosure for EVOLUTION Series modules ( ) This module container is realized by authorization of the Bticino spa company and is suitable to house the Living International, Luna, x5 5.0 Light and Light Tech modules which are registered trademarks owned by Bticino. Flange x5mm x5x5 (8x0mm) i 5.0 (*) When assembled together with the relevant component. - Closes the cut-outs foreseen for OMNIA Series flush mounting sockets with interlock. - Supplied with gasket for IP7 and stainless steel screws. Examples of installation - flange x5 MBOX Series EVOLUTION Series insert mounted on DIN rail support OMNIA System DOMINO Series 00 DIN rail support module art modules art

9 ADVANCE System switched socket outlets with interlock >V. SURFACE MOUNTING - IP ADVANCE Series Poles Hz. Volt Colour h. COMPACT WITHOUT FUSE HOLDER A M5 / M5 / COMPACT WITH FUSE HOLDER A M5 / M5 / LARGE WITH RAIL DIN ( MODULES) A M5 / M5 / / / / P+E / /0 trasf. >00-0 () > c.c. () >- c.c. () > 8 / / / P+E / /0 () () > >00-0 () > / / / P+N+E / /0 () >00-0 () > Rated voltage >V - Approvals: from page 5 - Switches as spare parts: page 88 - Supplied with stainless steel fixing screws. () The maximum amount of current available, taking into account the maximum overheating temperature allowed by the relevant standards, must be downgraded with respect to the nominal current by 5% for products with frequencies ranging 0 above 00 Hz; contact Scame Technical Service for further information. () When using DC we recommend that you make sure of implementing the protection scheme that is most suitable for the system involved; contact Scame Technical Service for further information. () Pay special attention when selecting the appropriate fuse with respect to the tension of the installation. ADVANCE System From page 0 0

10 ADVANCE System switched socket outlets with interlock >V. SURFACE MOUNTING - IP/IP ADVANCE Series Poles Hz. Volt Colour h. A M5 / COMPACT WITHOUT FUSE HOLDER M5 / LARGE WITHOUT FUSE HOLDER A M0 / A M5 / COMPACT WITH FUSE HOLDER M5 / LARGE WITH FUSE HOLDER A M0 / A M5 / LARGE WITH RAIL DIN ( MODULES) M5 / A M0 / / / / P+E / /0 trasf. >00-0 () > c.c. () >- c.c. () > 8 / (*) (*) / / (*) (*) P+E / /0 () () > >00-0 () > / / / (*) (*) P+N+E / /0 () >00-0 () > (*) 00V only Rated voltage >V - Approvals: from page 5 - Switches as spare parts: page 88 - Supplied with stainless steel fixing screws. () The maximum amount of current available, taking into account the maximum overheating temperature allowed by the relevant standards, must be downgraded with respect to the nominal current by 5% for products with frequencies ranging 0 above 00 Hz; contact Scame Technical Service for further information. () When using DC we recommend that you make sure of implementing the protection scheme that is most suitable for the system involved; contact Scame Technical Service for further information. () Pay special attention when selecting the appropriate fuse with respect to the tension of the installation. ADVANCE System From page 0 05

11 ADVANCE System switched socket outlets with interlock >V. SURFACE MOUNTING - IP/IP7 - HD VERSION ADVANCE-HD Series Poles Hz. Volt Colour h. HD COMPACT - WITH FUSE HOLDER A M5 / M5 / HD LARGE - WITH FUSE HOLDER A M0 / A M5 / HD LARGE - WITH RAIL DIN ( MODULES) M5 / A M0 / / / / P+E / /0 trasf. >00-0 () > c.c. () >- c.c. () > 8 / (*) (*) / / (*) (*) P+E / /0 () () > >00-0 () > / / / (*) (*) P+N+E / /0 () >00-0 () > (*) 00V only Rated voltage >V - Approvals: from page 5 - Switches as spare parts: page 88 - Supplied with stainless steel fixing screws. () The maximum amount of current available, taking into account the maximum overheating temperature allowed by the relevant standards, must be downgraded with respect to the nominal current by 5% for products with frequencies ranging 0 above 00 Hz; contact Scame Technical Service for further information. () When using DC we recommend that you make sure of implementing the protection scheme that is most suitable for the system involved; contact Scame Technical Service for further information. () Pay special attention when selecting the appropriate fuse with respect to the tension of the installation. ADVANCE System From page 0 07

12 ADVANCE System switched socket outlets with interlock <V. SURFACE MOUNTING - IP AND IP/IP7 Rated Socket Type Colour h voltage IP - COMPACT IP - LARGE IP/IP7 - COMPACT IP/IP7 - LARGE With Normal - V~ /0 transformer () P-A Heavy duty - V~ /0-0-5V~ /0 Normal 0-V~ /0 P-A - 0-5V~ /0 With RAIL Heavy duty 0-V~ /0 DIN ( modules) - 0-5V~ /0 Normal 0-V~ /0 P V~ /0 Heavy duty 0-V~ / /S 5./S 55.0/S 55./S 5.0/S 5./S 55./S 55./S 5./S 5./S ADVANCE Series 55.5/S 5.5/S A 0V Primary circuit Transformer A V Secondary circuit Protections for the version with transformer, large type. Fuses included Rated voltage >V - Approvals: from page 5 - When the plug is inserted a micro-switch turns on that closes the circuits. - Cable gland M5. () SELV transformer g0/v~ VA (continuous duty). ADVANCE System From page

13 ADVANCE System Modular system - IP. MODULE 0 (COMPACT) - STANDARD VERSION Modular bases Complete with inserts for joining several bases ( ) ADVANCE System A- FLANGE 70X87 DIN 0 DIN One-module with cut out - i 57.0 Enclosures IP One-module plain lid - Two-modules plain lid - One-module with window 8W Two-modules with window W - Modularity: ADVANCE Series compact (from page 0). MODULE 0 (COMPACT) - HEAVY DUTY VERSION i 57.0 i 57.0 i 57.0 i ADVANCE System ( ) A- DIN 0 DIN Modular bases Complete with inserts for joining several bases Enclosures IP Combination One-module with cut out - - One-module plain lid - Two-modules plain lid - One-module with window 8W Two-modules with window W - Modularity: ADVANCE-HD Series compact (from page 0). i i Note: The enclosure is supplied with screws for fastening the lid and mounting to the boxes; the kit also includes, metric coupler, seals and nuts: in order to carry out precise performance for metric shunt boxes, we recommend the use of stepped milling cutter. i i ( ) calculated according to CEI -9 Italian standard. The Heavy Duty products are suitable to heavy working conditions and are also resistant to highly salty environments. COMPACT CODE JUNCTION BOXES WITH ADVANCE COMPACT WITH ADVANCE LARGE DIFFERENT COMBINATIONS WITH ADVANCE AND OMNIA SOCKET OUTLETS 0

14 ADVANCE System Modular system - IP. MODULE (LARGE) - STANDARD VERSION Modular bases Complete with inserts for joining several bases ( ) ADVANCE System A--A FLANGE 70X87 DIN DIN One-module with cut out - i 57. Enclosures IP One-module plain lid - Two-modules plain lid - One-module with window 9W Two-modules with window 7W - Modularity: ADVANCE Series compact and large (from page 0), OMNIA Series (from page 9). MODULE (LARGE) - HEAVY DUTY VERSION i 57. i 57. i 57. i 57.5 ADVANCE System ( ) A--A DIN DIN Modular bases Complete with inserts for joining several bases Enclosures IP One-module with cut out - - One-module plain lid - Two-modules plain lid - One-module with window 9W Two-modules with window 7W - Modularity: ADVANCE-HD Series compact and large (from page 0). Combination i 578. i 578. Note: The enclosure is supplied with screws for fastening the lid and mounting to the boxes; the kit also includes, metric coupler, seals and nuts: in order to carry out precise performance for metric shunt boxes, we recommend the use of stepped milling cutter. i 578. i ( ) calculated according to CEI -9 Italian standard. The Heavy Duty products are suitable to heavy working conditions and are also resistant to highly salty environments. LARGE CODE 57.0 JUNCTION BOXES WITH ADVANCE COMPACT WITH ADVANCE LARGE DIFFERENT COMBINATIONS WITH ADVANCE AND OMNIA SOCKET OUTLETS

15 ADVANCE-GRP System Switched interlocked socket outlets >V. WITHOUT BASE - IP/IP7 - WITHOUT FUSE HOLDER ADVANCE-GRP Series A A A I-DEVICE A Poles Hz. Volt Colour h. / / / P+E / /0 trasf. >00-0 () > c.c. () >- c.c. () > / / / P+E / /0 () () > >00-0 () > / / / P+N+E / /0 () >00-0 () > Rated voltage >V - Approvals: from page 5 - Switches as spare parts: page 88 - Supplied with stainless steel fixing screws. () The maximum amount of current available, taking into account the maximum overheating temperature allowed by the relevant standards, must be downgraded with respect to the nominal current by 5% for products with frequencies ranging above 00 Hz; contact Scame Technical Service for further information. () When using DC we recommend that you make sure of implementing the protection scheme that is most suitable for the system involved; contact Scame Technical Service for further information. () Pay special attention when selecting the appropriate fuse with respect to the tension of the installation. ADVANCE-GRP System From page 5

16 ADVANCE-GRP System Switched interlocked socket outlets >V. WITHOUT BASE - IP/IP7 - WITH FUSE HOLDER ADVANCE-GRP Series A A A I-DEVICE A Poles Hz. Volt Colour h. / F 0.70-F 0.70-F 0.70-F 0.70-F 0.70-F / F 0.8-F 0.8-F 0.8-F 0.8-F 0.8-F / P+E / /0 trasf. >00-0 () > c.c. () >- c.c. () > F 0.8-F 0.8-F 0.8-F 0.78-F 0.8-F 0.8-F 0.8-F 0.78-F 0.8-F 0.8-F 0.8-F 0.78-F 0.8-F 0.8-F 0.78-F 0.8-F 0.8-F 0.78-F 0.8-F 0.8-F / F 0.7-F 0.7-F 0.7-F 0.7-F 0.7-F / F 0.7-F 0.7-F 0.7-F 0.7-F 0.7-F / F 0.8-F 0.8-F 0.8-F 0.8-F 0.8-F F 0.85-F 0.85-F 0.85-F 0.85-F 0.85-F P+E / F 0.8-F 0.8-F 0.8-F 0.8-F 0.8-F /0 () () > F 0.8-F 0.8-F 0.87-F 0.8-F 0.8-F 0.87-F 0.8-F 0.8-F 0.87-F 0.8-F 0.87-F 0.8-F 0.87-F 0.8-F P+N+E >00-0 () > / / /0-5 / /0 () >00-0 () > 0.8-F 0.79-F 0.75-F 0.87-F 0.87-F F F 0.87-F 0.87-F 0.8-F 0.79-F 0.75-F 0.87-F 0.87-F F F 0.87-F 0.87-F 0.8-F 0.79-F 0.75-F 0.87-F 0.87-F F F 0.87-F 0.87-F 0.79-F 0.75-F 0.87-F 0.87-F F F 0.87-F 0.79-F 0.75-F 0.87-F 0.87-F F F 0.87-F 0.79-F 0.75-F 0.87-F 0.87-F F F 0.87-F An electronic device controls (Intelligence Device) the status of the interlocked socket, monitoring the electrical functionality: - operation of the signalling and control card is guaranteed even when the load is not connected; INDICATOR LIGHT ON - indicates that the fuses are not open and all the phases are present; - indicates that the socket outlet is powered correctly; INDICATOR LIGHT FLASHING - signals the interruption of one or more fuses; - signals the absence of a phase*; INDICATOR LIGHT OFF - indicates that the socket outlet is not powered. * for single-phase products in the event of phase/neutral loss led signaling appears off. Rated voltage >V - Approvals: from page 5 - Switches as spare parts: page 88 - Supplied with stainless steel fixing screws. () The maximum amount of current available, taking into account the maximum overheating temperature allowed by the relevant standards, must be downgraded with respect to the nominal current by 5% for products with frequencies ranging above 00 Hz; contact Scame Technical Service for further information. () When using DC we recommend that you make sure of implementing the protection scheme that is most suitable for the system involved; contact Scame Technical Service for further information. () Pay special attention when selecting the appropriate fuse with respect to the tension of the installation. System ADVANCE-GRP From page 7

17 ADVANCE-GRP System Switched interlocked socket outlets >V. SURFACE MOUNTING I-DEVICE - IP - WITHOUT FUSE HOLDER ADVANCE-GRP Series ACCESSORIES ADVANCE-GRP Series Poles Hz. Volt Colour h. P+E /0 00- P+E / A A.8.8 5A Microswitch kit 00V 0A (microswitch + terminal block) - Max kit. - For products with mechanical interlock. Contacts Terminals NO+NC x mm P+N+E / SURFACE MOUNTING I-DEVICE - IP - WITH FUSE HOLDER ADVANCE-GRP Series A A 5A 5A 5A 5A 5A Poles Hz. Volt Colour h. P+E / F.8-F.8-F.58-F.58-FS.58-M.58-RM.58-T P+E / F.8-F.8-F.58-F.58-FS.58-M.58-RM.58-T P+N+E / F.87-F.87-F.587-F.587-FS.587-M.587-RM.587-T Rated voltage >V - Approvals: from page 5 ADVANCE-GRP System From page With switch-disconnector With switch-disconnector and fuse Fuses not included With fuse and switchdisconnector Fuses not included With molded case circuit breaker with thermal magnetic trip unit With molded case circuit breaker with thermal magnetic and residual current release trip units Contactor operated by microswitch Microswitch already provided 8 9

18 ADVANCE-GRP System Switched interlocked socket outlets <V. WITHOUT BASE - IP/IP7 ADVANCE-GRP Series SURFACE MOUNTING - IP - WITH FUSE HOLDER ADVANCE-GRP Series With transformer (*) Without transformer Plug Colour Rated voltage P-A 0-5V~ P-A P- 0-5V~ 0-5V~ 0-V~ 0-V~ With transformer (*) Plug Colour Rated voltage P-A 0-5V~.-F Wiring operations Wiring capacity of the terminals (mm ) Rated current (A) A Min Socket outlets Max 0 Socket without transformer wiring diagram P A P Note: external transformer Rated voltage >V - Approvals: from page 5 - For the choice of bottoms, refer to thea- module. (*) SELV trasformer g 0/V~ VA. ADVANCE-GRP System From page 0

19 ADVANCE-GRP System modular system. BASES AND CONSUMER UNIT - IP/IP7 ADVANCE-GRP System GALVANIZED STEEL SUPPORTS ADVANCE-GRP System Base for one socket Module DIN Module HxB (W) A- A- - 0x A - 80x A HxB xa- 555x xa- 555x Base for one socket with derivation box Module DIN Module HxB (W) A- - 0x A - 580x HxB xa- + xa 85x xa- + xa 85x xa- + xa 85x Composition examples Module DIN Module HxB (W) Base for one socket with consumer unit A- 0x A 8 580x M bottom jointing Kit (page ) Module DIN Module HxB (W) Base for two sockets with derivation box A- - 0x A Base for two sockets with consumer unit Module DIN Module HxB (W) A- - 0x A in conformity with CEI -8 CEI IP/IP7 when coupled with the respective component.

20 ADVANCE-GRP System modular system. ACCESSORIES ADVANCE-GRP System AS panels Microswitch Kit for Advance GRP A--A for plug-inserted control Contact Max kit for A- sockets; Max kit for A sockets. NO/NC / Junction box Kit IP/IP7 (A--A) M0 (*) / Junction box Kit IP/IP7 (A) M (*) / M bottom jointing Kit M / (*) Includes cable gland and gasket. - IP/IP7 when coupled with the respective component. AUXILIARY CONTACTS ADVANCE-GRP System NC Contact NA Contact NC= normally closed. For switches A PL0000 A PL0000 A PL0000 A PL0000 NA= normally open. Example of Mega Panel available in customized configuration. M bottom jointing Kit. Auxiliary contact assembled. 5

UNIBOX Series Enclosure and wiring accessories IP40-IP55

UNIBOX Series Enclosure and wiring accessories IP40-IP55 UNIBOX Series Enclosure and wiring accessories IP-IP55 UNIBOX Series > ENCLOSURE FOR WIRING ACCESSORIES > REFERENCE STANDARDS EN 60670-1 Boxes and enclosures for electrical accessories for household and

More information

ADVANCE GRP Series 125A Switched Interlocked socket outlets

ADVANCE GRP Series 125A Switched Interlocked socket outlets DVNCE GRP Series 125 Switched Interlocked socket outlets DVNCE GRP Series 125 > SWITCHED INTERLOCKED SOCKET OUTLETS > REFERENCE STNDRDS EN 60309-1 Plugs, socket outlets and couples for industrial purposes.

More information

information service Page 1

information service Page 1 Page 1 TO ALL OUR CUSTOMERS 1. NEW OMNIAPLUS SERIES DOMESTIC INTERLOCKED SOCKET The SCAME product line of interlocked sockets has been enhanced with the new OMNIAPLUS Series: The first interlocked socked

More information

2.3 Cable reels for industrial applications. AUTOROLLER Series ROLLER330 Series ROLLER450 Series ROLLER-BLOCK Series

2.3 Cable reels for industrial applications. AUTOROLLER Series ROLLER330 Series ROLLER450 Series ROLLER-BLOCK Series . reels for industrial applications. ROLLER0 ROLLER50 ROLLER-BLOCK 60 6 reels with automatic rewind. WITH H05VV-F PVC CABLE - IP Type Metres x 6 00 00 75.00-D poles x,5 500 00 75.05-D x,5 0 000 00 75.05-D

More information

3.2 DOMINO Series... from page c. 126

3.2 DOMINO Series... from page c. 126 . Series.......................................................................................... from page c. 6 The System offers a complete range of consumer units and sealed mounted enclosures for

More information

ADVANCE System ADVANCE SYSTEM IP66 MODULAR SYSTEM FOR COMBINATION UNITS VERSIONS MODULE 136 MODULE 106. t. 56. Without protective devices

ADVANCE System ADVANCE SYSTEM IP66 MODULAR SYSTEM FOR COMBINATION UNITS VERSIONS MODULE 136 MODULE 106. t. 56. Without protective devices ADVANCE System ADVANCE SYSTEM IP66 MODULAR SYSTEM FOR COMBINATION UNITS Without protective devices Interlocked-switch socket outlets QUADRA Series socket outlets For 16 and 32 A currents Protection degree

More information

Distribution boards. 68 Q-DIN Range

Distribution boards. 68 Q-DIN Range Complete electric boards system for energy distribution in commercial, industrial and costrucion sites places. Available in both empty and wired version, in compliance with the IEC 61439 Standard: Versions

More information

INDUSTRIAL PLUGS AND SOCKETS. Optima, Eureka, Xenia, IEC309 Series

INDUSTRIAL PLUGS AND SOCKETS. Optima, Eureka, Xenia, IEC309 Series INDUSTRIAL PLUGS AND SOCKETS Optima, Eureka, Xenia, IEC309 Series Scame: a tradition of innovation IN FIFTY YEARS WE HAVE WRITTEN A STORY OF INNOVATION THAT HAS ALWAYS PRESERVED THE SPIRIT OF ITS ORIGINS.

More information

OMNIA System OMNIA SYSTEM - IP55 FLUSH AND SURFACE MOUNTING MODULAR SYSTEM. t. 50

OMNIA System OMNIA SYSTEM - IP55 FLUSH AND SURFACE MOUNTING MODULAR SYSTEM. t. 50 OMNIA System OMNIA SYSTEM - IP55 FLUSH AND SURFACE MOUNTING MODULAR SYSTEM The flush mounting box, which is suitable for walled installations, can be combined both horizontally and vertically with any

More information

Plug 16A 2P+E extra flat Wireable (body length up to 50 mm) SPA17. Plug 10A 2P+E straight S11. Plug 16A 2P+E straight S30. Plug 16A angled S30

Plug 16A 2P+E extra flat Wireable (body length up to 50 mm) SPA17. Plug 10A 2P+E straight S11. Plug 16A 2P+E straight S30. Plug 16A angled S30 CONTROL DEVICE REFERENCE STANDARDS UNSWITCH SOCKET OUTLETS EN 60669-1 Switches for household and similar fixed-electrical installation. Part 1: general requirements. Rated current: 10A-13A-15A-16A Rated

More information

DOMINO Series surface mounting IP55

DOMINO Series surface mounting IP55 Series surface mounting IP55 SERIES CONSUMER UNITS SURFACE MOUNTING VERSION - IP55 REFERENCE STANDARDS International standard IEC 60670 (989) and the Modification (994) Part : General requirements for

More information

68 Q-DIN Range. Trade Catalogue Energy 2013 > Energy > Combined units to IEC 309 > 68 Q-DIN Range. Distribution boards UNWIRED VERSIONS

68 Q-DIN Range. Trade Catalogue Energy 2013 > Energy > Combined units to IEC 309 > 68 Q-DIN Range. Distribution boards UNWIRED VERSIONS Kombi cent r al er 0 8 5 9 41 1 83 0 www. mwa. s ei nf o@mwa. s e UNWIRED VERSIONS Type No. EN 50022 modules 1 IEC 309 socket-outlet 16A IP44/67 or GW 27 401 or GW 27 403 watertight cap GW 68 018 N 2 IEC

More information

TechData. Master data. P/N: SCM460MI7W INTERLOCK SOCKET 3P+E IP67 60A 7h **Supplied with base

TechData. Master data. P/N: SCM460MI7W INTERLOCK SOCKET 3P+E IP67 60A 7h **Supplied with base ddendum 1/11/1 rticle Picture P/N: SCM0MI7W INTERLOCK SOCKET P+E IP7 0 7h **Supplied with base 79.0 P/N SCM0MI7WNB INTERLOCK SOCKET P+E IP7 0 7h **No base supplied. Select base below. Base Options: Single:

More information

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module transformers and buzzers and bells socket outlets and special supports 042 25 042 52 041 07 042 80 042 85 Pack Cat.Nos Bell transformers dconform to IEC / EN 61558-2-8 Protected against overloads and short

More information

MASTERBOX Series MASTERBOX SERIES DISTRIBUTION ASSEMBLIES

MASTERBOX Series MASTERBOX SERIES DISTRIBUTION ASSEMBLIES MASTERBOX Series MASTERBOX SERIES DISTRIBUTION ASSEMBLIES VERSIONS They come in two sizes (WxHxD): MASTERBOX 70 x 580 x 50mm MASTERBOX 5 70 x 580 x 50mm Installation: - surface mounting - elevated with

More information

Commando Safetyswitch

Commando Safetyswitch 80 Commando Safetyswitch Commando Safetyswitches are manufactured from Polybutylene Terephthalate (PBT) for maximum impact resistance. The range offers a selection of IP54 and IP65 ratings to cover a variety

More information

3.1 Distribution assemblies... from page 465 DISTRIBUTION ASSEMBLIES

3.1 Distribution assemblies... from page 465 DISTRIBUTION ASSEMBLIES Index for section..... from page 5 DISTRIBUTION ASSEMBLIES. for industrial applications... from page 7. Cable reels for industrial applications... from page 59 MEGA Series MASTERBOX Series MBOX Series

More information

DOMINO Series IP40. Surface and flush mounting consumer units

DOMINO Series IP40. Surface and flush mounting consumer units DOMINO Series IP40 Surface and flush mounting consumer units DOMINO Series DOMINO SERIES CONSUMER UNITS AND ENCLOSURES DOMINO Series consumer units are characterised by their modularity and the ease with

More information

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE. Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE Distributor : LEGRAND ELECTRIC LIMITED Great King Street North, Birmingham, B19 2LF Tel : 0870 608 9000 Fax : 0870 608 9004 CONSUMER UNIT BRO.10.05.??K

More information

COMMAND Series. Switching-disconnectors units

COMMAND Series. Switching-disconnectors units COMMND Series Switchingdisconnectors units COMMND Series > ROTRY SWITCHES > REFERENCE STNDRDS EN 6097 Low voltage switchgear and controlgear. Part : switches disconnectors, switchdisconnectors and fusecombination

More information

CUSTOMIZED SOLUTIONS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates

CUSTOMIZED SOLUTIONS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates CUSTOMIZED SOLUTIONS MARECHAL offers a wide range of distribution boxes for all industrial applications and a large choice of products designed specifically for power-supply in tunnels. FIND ALL INFORMATION

More information

Cat N 3. OVERALL DIMENSIONS

Cat N 3. OVERALL DIMENSIONS Cat N Motor driven remote control module 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat N : : 4 062 91 CONTENTS PAGE 1. Description - Use...1 2. Product range...1

More information

INDUSTRIAL PLUGS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates

INDUSTRIAL PLUGS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates INDUSTRIAL PLUGS A range from 16 A to 600 A 1000 V. Automatic watertightness from IP44 to 66/67. From -40 to +240 C. GRP or metal casing. Reliable & compact. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com

More information

SOCKET-OUTLETS WITH PROTECTION

SOCKET-OUTLETS WITH PROTECTION BM MODULAR BOXES Assembly from 1 to 6 modules IP66/IP67 sealing 1 or 2 cable glands per side Range of protection levels available page 112 CD SOCKET-OUTLETS WITH PROTECTION From 16 up to 63 A RCD protection

More information

P17. Tempra PRO. a range you can rely on CATALOGUE PAGES INSIDE. GLOBAL SPECIALIST in electrical and digital building infrastructures

P17. Tempra PRO. a range you can rely on CATALOGUE PAGES INSIDE. GLOBAL SPECIALIST in electrical and digital building infrastructures P17 Tempra PRO a range you can rely on -> GLOBAL SPECIALIST in electrical and digital building infrastructures CATALOGUE PAGES INSIDE P17 TEMPRA PRO, suitable for all the P17 tempra Pro range incorporates

More information

20 A / 32 A / 63 A DECONTACTOR MOUNTING: SWITCH SHOULD BE ON THE UPPER SIDE!

20 A / 32 A / 63 A DECONTACTOR MOUNTING: SWITCH SHOULD BE ON THE UPPER SIDE! COMPACT AND WATERTIGHT DECONTACTOR 20 A / 32 A / 63 A AUTOMATIC ip66/ip67 water- and dust-tight sealing AC-22 and ac-23 breaking capacity Impact-resistant GRP casing With sizes from 20 to 63 A, DSN decontactors

More information

DECONTACTOR FOR INDUSTRY 30 A / 50 A / 90 A / 150 A / 250 A

DECONTACTOR FOR INDUSTRY 30 A / 50 A / 90 A / 150 A / 250 A DECONTACTOR FOR INDUSTRY 30 A / 50 A / 90 A / 150 A / 250 A SAFE AND SIMPLE CONNECTION, EVEN AT 250 A SAFETY SHUTTER GRP OR METAL CASING The DS family of decontactors offer ratings from 30 to 250 A (ratings

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

n 029/ June 2005 Page: 1

n 029/ June 2005 Page: 1 n 029/2005 - June 2005 Page: 1 TO ALL OUR CUSTOMERS 1. PRODUCT CHANGE: NEW ENCLOSURES AND DISCONNECTING SWITCHES FOR ISOLATORS 40A SERIES ISOLATORS 40A enclosures in thermoplastic and metal look new and

More information

TO ALL OUR CUSTOMERS. Poles

TO ALL OUR CUSTOMERS. Poles Page 1 TO ALL OUR CUSTOMERS 1. NEWS: NEW 20-32-40A THERMOPLASTIC ENCLOSURES FOR THE ISOLATORS SERIES The thermoplastic ISOLATORS series offer has been expanded, introducing a range of products for 20,

More information

EASYBOX Series. Weather-proof enclosures

EASYBOX Series. Weather-proof enclosures EASYBOX Series Weatherproof enclosures EASYBOX Series WEATHERPROOF ENCLOSURES IP65 REFERENCE STANDARDS INTERNATIONAL STANDARD IEC 60670 (989) plus Modification (994) Enclosures for accessories for fixed

More information

BOXES AND BOARDS. Versatility and modularity of solutions and materials STANDARD HEAVY DUTY

BOXES AND BOARDS. Versatility and modularity of solutions and materials STANDARD HEAVY DUTY BOXES AND BOARDS Versatility and modularity of solutions and materials STANDARD HEAVY DUTY 8 BOXES AND BOARDS Versatility and modularity of solutions and materials STANDARD PRIMA topter empty distribution

More information

building site system

building site system building site system Anti-UV AC3 10kA >20J V0-960 C energybox The safest The most functional The most convenient ASC distribution board for construction sites energybox more functional It s the easiest

More information

Rated current In (A) Other electrical data. IEC 309 range. EN see 70 RT range IK

Rated current In (A) Other electrical data. IEC 309 range. EN see 70 RT range IK 44 and 67 IB standard horizontal and vertical socket-outlets Industrial-type socket-outlets conforming to IEC 309 Standard, with mechanical interlock consisting of a circuit breaker enabling the plug to

More information

HEAVY-DUTY PLUGS & SOCKETS

HEAVY-DUTY PLUGS & SOCKETS HEAVY-DUTY PLUGS & SOCKETS 315 A/400 A/500 A/600 A Up to 600 A/1 000 V Automatic IP66/IP67 water-and dust-tight Mechanical and electrical interlocking Up to 6 auxiliary and 2 pilot contacts Marine aluminum

More information

ADVANCE- GRP S YS TEM. Switched Interlocked socket outlets [ ]

ADVANCE- GRP S YS TEM. Switched Interlocked socket outlets [ ] DVNCE GRP S YS TEM Switched Interlocked socket outlets DVNCEGRP System SWITCHED INTERLOCKED SOCKET OUTLETS 63263 REFERENCE STNDRDS EN 60309 Plugs, socket outlets and couplers for industrial purposes. Part

More information

Switches Section 1. Load Break Switches. Accessories for Load Break Switches. 4 Pole Part Price Each Reference

Switches Section 1. Load Break Switches. Accessories for Load Break Switches. 4 Pole Part Price Each Reference Load Break Switches According to BS EN60947-3 High Thermal & Dynamic Strength Fully rated suitable for distribution & motor loads Auxiliary contacts also available Fully Visible Breaking Arduous categories

More information

67 IB INTERLOCKED SOCKET-OUTLET IEC 309 STANDARDS

67 IB INTERLOCKED SOCKET-OUTLET IEC 309 STANDARDS Technical data and compliance with Standards Component Interlocked switched socket-outlets SELV socket-outlet Rotary switch MT60 miniature circuit breaker, C characteristic, 6kA Reference Standards EN

More information

SWITCH SHOULD BE ON THE UPPER SIDE!

SWITCH SHOULD BE ON THE UPPER SIDE! COMPACT AND WATERTIGHT DECONTACTOR 20 A / 32 A / 63 A AUTOMATIC WATER- AND DUST-TIGHT SEALING AC-22 AND AC-23 BREAKING CAPACITY IMPACT-RESISTANT GRP CASING With sizes from 20 to 63 A, DSN decontactors

More information

Solutions for CONSTRUCTION SITES

Solutions for CONSTRUCTION SITES Solutions for CONSTRUCTION SITES Ed. 01 2017 68 ACS range Efficiency, quality and safety in even the most heavy-duty environments. The 68 ACS range is a unique solution for construction site contexts,

More information

Low and Extra-Low voltage. PratiKa. Industrial plugs and sockets. Offer panorama

Low and Extra-Low voltage. PratiKa. Industrial plugs and sockets. Offer panorama Low and Extra-Low voltage PratiKa Industrial plugs and sockets Offer panorama Presentation PratiKa plugs and sockets General presentation PB102249 Additional safety is assured by sockets with electrical

More information

DSN COMPACT AND WATERTIGHT DECONTACTOR GRP 20 A/32 A/63 A

DSN COMPACT AND WATERTIGHT DECONTACTOR GRP 20 A/32 A/63 A DSN COMPACT AND WATERTIGHT DECONTACTOR GRP 20 A/32 A/63 A Automatic IP66/IP67/IP69k AC-22 and ac-23 breaking capacity Chemical resistant GRP UL 94 casing Impact resistance IK08, vibration resistance -40

More information

Combination Units. Combination Units do not present on this catalogue are available on request.

Combination Units. Combination Units do not present on this catalogue are available on request. Combination Units Combination Units Prewired combination units 11 unswitched or switchinterlocked with RCD, MCB or RCBO protection as standard. Multioutlet combination units unswitched with RCD, MCB or

More information

TUNNEL54. Safety and fire resistance VENTILATION LIGHTING

TUNNEL54. Safety and fire resistance VENTILATION LIGHTING TUNNEL54 Safety and fire resistance VENTILATION LIGHTING 238 TUNNEL54 Safety and fire resistance VENTILATION TUNNEL54 fire resistant sockets for ventilators Page 240 LIGHTING TUNNEL54 junction boxes with

More information

more power to the cube

more power to the cube more power to the cube Tais Cube designed in GRP thermosetting for tough enclosure applications where space, ingress protection, quick installation and long service life is important. available with blind

More information

DECONTACTOR SWITCH WITH SOCKET-OUTLET

DECONTACTOR SWITCH WITH SOCKET-OUTLET DECONTACTOR SWITCH WITH SOCKET-OUTLET This extensive and comprehensive product range covers all industrial applications. With sizes up to 400 A, it offers a wide range of mounting and installation options.

More information

IEC Low Voltage Products Module 4

IEC Low Voltage Products Module 4 IEC Low Voltage Products Module 4 IEC Low Voltage Products NH DIN o All variations o Features benefits o Dual indication IEC Cylindrical Fuse System o Wide range of sizes and ratings o CCP NEW Product!

More information

Internationally approved.

Internationally approved. E X - M A N U A L M O T O R S T A R T E R S Up to 2 A Motors have to be protected against over loads, phase failures and overheating: CEAG s power circuit breaker and manual motor starter features phase-failure

More information

Permissible overload. 22 A > A Hz > Hz 42 A > A. Heat resistance

Permissible overload. 22 A > A Hz > Hz 42 A > A. Heat resistance IEC 309 HP technical characteristics New range of plugs and socket-outlets meeting the dimensional, construction/performance and safety requisites defined by the international Standards IEC 60309-1 and

More information

SWITCH FUSES 3KL71 from 32A to 800A Description

SWITCH FUSES 3KL71 from 32A to 800A Description from 32A to 800A Description SWITCH FUSES 3KL71 3KL71 is a range of load-break switches suitable for making and breaking on load and disconnetting low voltage electrical circuits. They are commonly used

More information

SWITCH SHOULD BE ON THE UPPER SIDE!

SWITCH SHOULD BE ON THE UPPER SIDE! COMPACT AND WATERTIGHT DECONTACTOR 20 A / 32 A / 63 A AUTOMATIC WATER- AND DUST-TIGHT SEALING AC-22 AND AC-23 BREAKING CAPACITY IMPACT-RESISTANT GRP CASING With sizes from 20 to 63 A, DSN decontactors

More information

Greater protection UNDERSTANDING THE 17TH EDITION CONSUMER UNITS / PRODUCT GUIDE

Greater protection UNDERSTANDING THE 17TH EDITION CONSUMER UNITS / PRODUCT GUIDE Greater protection UNDERSTANDING THE 17TH EDITION CONSUMER UNITS / PRODUCT GUIDE Summary of changes Simplifying the 17 th Edition Understanding new regulations is never easy... that s why we ve tried to

More information

GENERAL CATALOGUE Leading Electrotechnology

GENERAL CATALOGUE Leading Electrotechnology GENERAL CATALOGUE 2014-2015 Leading Electrotechnology THE WORLD HAS CHOSEN PALAZZOLI excellence FROM ITALY The globalisation process no longer allows for Made in Italy to be the only mark of differentiation

More information

315 A / 400 A / 500 A / 600 A

315 A / 400 A / 500 A / 600 A PF HEAVY-DUTY PLUGS & SOCKETS 315 A / 400 A / 500 A / 600 A UP TO 600 A / 1000 V AUTOMATIC WATER- AND DUST-TIGHT MECHANICAL AND ELECTRICAL INTERLOCKING UP TO 6 AUXILIARY AND 2 PILOT CONTACTS Big equipment

More information

DSN COMPACT AND WATERTIGHT DECONTACTOR GRP 20 A/32 A/63 A

DSN COMPACT AND WATERTIGHT DECONTACTOR GRP 20 A/32 A/63 A DSN COMPACT AND WATERTIGHT DECONTACTOR GRP 20 A/32 A/63 A Automatic IP66/IP67/IP69k AC-22 and ac-23 breaking capacity Chemical resistant GRP UL 94 casing Impact resistance IK08, vibration resistance -40

More information

Pack Cat. Nos. Single pole push switches gang 2 way push switch gang 2 way push switch marked PRESS gang 2 way

Pack Cat. Nos. Single pole push switches gang 2 way push switch gang 2 way push switch marked PRESS gang 2 way white 7300 00 7300 02 7300 07 7301 07 7301 33 7300 06 7300 08 7300 09 Terminal screws captive and backed off ready for cabling Surface mounting boxes (see p. 112) Pack Cat. os. Single pole plate switches

More information

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1 > For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX

More information

EQUIPMENT FOR CONNECTION OF A PHOTOVOLTAIC INSTALLATION (UP TO 5 KW)

EQUIPMENT FOR CONNECTION OF A PHOTOVOLTAIC INSTALLATION (UP TO 5 KW) Catalogue photovoltaic installations 2005 EQUIPMENT FOR CONNECTION OF A PHOTOVOLTAIC INSTALLATION (UP TO 5 KW) "POSSIBILITY OF ASSEMBLY FOR BIDIRECTIONAL ELECTRONIC MONOPHASE METER FOR ALL VERSIONS". MODULAR

More information

Electrical switches and sockets RHYME

Electrical switches and sockets RHYME Electrical switches and sockets RHYME Packing: 10/100 pcs White metallic Champagne metallic Gold metallic Grey metallic Graphite metallic Coffee metallic TV socket 11251 11252 11253 11254 11255 11256 Packing:

More information

1 Phase electronic contactor (SC 1)

1 Phase electronic contactor (SC 1) 1 Phase electronic contactor (SC 1) - Rated operational voltage up to 600VAC 50/60 Hz - Rated operational current up to 15/30A/50/63A AC-1 - Control voltage from or - Compact modular design 22.5, 45, or

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Compact Emergency Light Fittings C-LUX 6108 (Zones 1 & 2, 21 & 22) C-LUX 6508 (Zones 2, 22) 01908E00 Series C-LUX 6108 and 6508 compact emergency lighting fitting can be used for

More information

COMPLETE SOLUTIONS FOR POWER PROTECTION

COMPLETE SOLUTIONS FOR POWER PROTECTION COMPLETE SOLUTIONS FOR POWER PROTECTION GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Modular protection P. 8 RX 3 MCBs 63 A 4500 & 6000 P. 18 DX 3 -IS isolating switches P. 9 RX

More information

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Emergency Light Fittings Series C-LUX 6108 / 6508 > Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5

More information

1.6 CEEGO Series...from page c.42. The CEEGO range, in both single and 3-phase, is manufactured in current ratings of 16, 32, 63 and 125 amperes.

1.6 CEEGO Series...from page c.42. The CEEGO range, in both single and 3-phase, is manufactured in current ratings of 16, 32, 63 and 125 amperes. 1.6 CEEGO Series.....................................................................................................from page c.42 The CEEGO range, in both single and 3-phase, is manufactured in current

More information

Plexo IP 55 to IP 66. Makes your day, rain or shine PLEXO / WEATHERPROOF WIRING DEVICES

Plexo IP 55 to IP 66. Makes your day, rain or shine PLEXO / WEATHERPROOF WIRING DEVICES Plexo IP 55 to IP 66 Makes your day, rain or shine PLEXO / WEATHERPROOF WIRING DEVICES Plexo IP 55 Ingenious features for easy installation > > Time saving guaranteed: no cut-out Uncut pier ceable membrane

More information

Tunnel catalogue 2016 SOLUTIONS FOR ROADWAY, RAILWAY AND UNDERGROUNDS

Tunnel catalogue 2016 SOLUTIONS FOR ROADWAY, RAILWAY AND UNDERGROUNDS Tunnel catalogue 2016 SOLUTIONS FOR ROADWAY, RAILWAY AND UNDERGROUNDS Leading Electrotechnology In 1904 PALAZZOLI began its activity in Brescia when electrical energy was first used in the industry. The

More information

INDUSTRIAL DECONTACTOR & CONNECTOR SYSTEMS

INDUSTRIAL DECONTACTOR & CONNECTOR SYSTEMS COLTERLEC ELECTRICL ENGINEERING PRODUCTS SECTION INDUSTRIL DECONTCTOR & CONNECTOR SYSTEMS Industrial Decontactor & Connector Systems COLTERLEC ELECTRICL ENGINEERING PRODUCTS 385 TM Industrial Decontactors

More information

DNROBUST DECONTACTOR 20 A / 30 A / 50 A / 90 A / 150 A SILVER-NICKEL BUTT CONTACTS

DNROBUST DECONTACTOR 20 A / 30 A / 50 A / 90 A / 150 A SILVER-NICKEL BUTT CONTACTS DNROBUST DECONTACTOR 20 A / 30 A / 50 A / 90 A / 150 A AUTOMATIC IP54/ WATER- AND DUST-TIGHT IMPACT-RESISTANT METAL CASING SUITABLE FOR HEAVY INDUSTRY The DN family of decontactors cover ratings from 30

More information

xboard safety, reliability effectively combining and performance safety, reliability and performance in commercial and industrial applications

xboard safety, reliability effectively combining and performance safety, reliability and performance in commercial and industrial applications xboard commercial and industrial panelboards xboard effectively combining safety, reliability and performance safety, reliability and performance in commercial and industrial applications NEW xboard (xdb)

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

Low voltage switch gear

Low voltage switch gear Low voltage switch gear Omron is an established global manufacturer of low voltage switch gear (LVSG) products, and the company s new series (J7) complements the existing portfolio. High power-handling

More information

Busbar Systems Accessories

Busbar Systems Accessories Busbar Systems Accessories SU1 SU Busbar Material: Thermoplastic Polyester Rated voltage up to 1000V, 50-60Hz Inserts can be used to facilitate the use of smaller busbar SU Busbar holders - Rated up to

More information

Maximum performance. Always.

Maximum performance. Always. 54 Maximum performance. Always. Rotary control devices in box A23A A3 INSTALLATION LASS, ONDITIONAL SHORT IRUIT URRENT 0,000A. THEY ALLOW DIRET ONTROL OF HIGHLY INDUTIVE LOADS. THEY ELIMINATE OSTLY MAHINE

More information

Clarian uk ltd SWITCHES AND CONTROLS TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC.

Clarian uk ltd SWITCHES AND CONTROLS TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC. SWITCHES AND CONTROLS TOP-TECHNIC TOP-TECHNIC CONTROL UNITS SWITCH DISCONNECTORS & CAM SWITCHES TOP-TECHNIC TOP-TECHNIC EMERGENCY STOP MAIN SWITCHES MAIN SWITCHES TOP-TECHNIC TOP-TECHNIC CAM SWITCHES FOR

More information

MOTOR CONNECTIONS MOTOR-DECONTACTOR & INDUSTRIAL PLUGS & SOCKET-OUTLETS. hyconelec.co.za MARECHAL TECHNOLOGY

MOTOR CONNECTIONS MOTOR-DECONTACTOR & INDUSTRIAL PLUGS & SOCKET-OUTLETS. hyconelec.co.za MARECHAL TECHNOLOGY MOTOR CONNECTIONS MOTOR-DECONTACTOR & INDUSTRIAL PLUGS & SOCKET-OUTLETS hyconelec.co.za MARECHAL TECHNOLOGY SAFE AND RELIABLE ELECTRICAL CONNECTIONS FOR YOUR MOTORS. MARECHAL ELECTRIC offers a range of

More information

An innovative technology

An innovative technology The range An innovative technology Description The new are load break switches that combine attractive style and optimised features due to their innovative design. This range, dedicated to industrial applications,

More information

Code Description Type Symbol No. Pack. Code Description Type No. Pack. Code Description Type No. Pack

Code Description Type Symbol No. Pack. Code Description Type No. Pack. Code Description Type No. Pack TRADE CATALOGUE UNIVERSAL RANGE CONTROL DEVICES CIRCUIT BREAKERS - 250V~ Code Description Type Symbol No. Pack GW 20 571 1P - 16AX General 1 80/320 GW 20 572 1P - 16AX Luminous 230 V ~ (0,4W) 1 30/60 GW

More information

I Ex-safety switches I

I Ex-safety switches I 3-pole, 20 A Technical data Ex-safety switches 20 A for controlled three-phase drives Marking accd. to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99

More information

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

SIRCO M and MV Universal load break switches from 16 to 160 A

SIRCO M and MV Universal load break switches from 16 to 160 A SRCO M and MV from 16 to 16 A The solution for Load break switches sircm_99_a > Main incoming load break > Distribution load break > Machine control > Local safety load break sircm_13_a 4 pole SRCO MV

More information

PKZ and PKE motor-protective circuit-breakers

PKZ and PKE motor-protective circuit-breakers PKZ and PKE motor-protective circuit-breakers Machinery and installation downtimes should be kept as short as possible. The PKZ fuseless motor-protective circuit-breakers combine short-circuit and overload

More information

Empty enclosures IEC 62208

Empty enclosures IEC 62208 374 www.hensel-electric.de/en in accordance with for customized solutions and individual applications for example for low-voltage switchgear and controlgear assemblies i n accordance with the IEC 61439-series

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

ICG Switchgear Price List 2009

ICG Switchgear Price List 2009 ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section

More information

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?... Load break switches Load break switches for all your applications.................................... Why choose a load break switch designed for photovoltaic applications?............. Load break switch

More information

NB1 Miniature Circuit Breaker

NB1 Miniature Circuit Breaker P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide

More information

STANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011

STANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011 Page 1 of 6 STANDARD SPECIFICATION FOR LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs Rev No. Issue Date Pages Rev Description Prepared By Checked By Approved By 0 15.07.2008 6 Issued for FEED MSJ VDV VDV

More information

Consumer Switchboards and Circuit Protection Flexible range designed for domestic and commercial installations

Consumer Switchboards and Circuit Protection Flexible range designed for domestic and commercial installations Consumer Switchboards and Circuit Protection Flexible range designed for domestic and commercial installations POWER DISTRIBUTION AND PROTECTION NHP Electrical Engineering Products Pty Ltd AUS NZ 1300

More information

PLUGS, SOCKET-OUTLETS, INDUSTRIAL DISTRIBUTION BOARDS AND TURRETS

PLUGS, SOCKET-OUTLETS, INDUSTRIAL DISTRIBUTION BOARDS AND TURRETS Section UNAV PLUGS AND INTERLOCKED SOCKET-OUTLETS PLUGS AND INTERLOCKED SOCKET-OUTLETS 229 PLUGS, SOCKET-OUTLETS, INDUSTRIAL DISTRIBUTION BOARDS AND TURRETS GROUND DISTRIBUTION TURRETS 234 ENCLOSURES AND

More information

Residential and light commercial. invicta. panelboards

Residential and light commercial. invicta. panelboards Residential and light commercial invicta panelboards Your simple energy distribution solution As an industry leader in power distribution, we strive to create innovative products that make installations

More information

CombinationUnits.

CombinationUnits. ZP00656-GB-1 8 0 0 1 6 3 6 4 0 7 1 8 0 CombinationUnits ScameOnLine http://www.scame.com e-mail: export@scame.com SCAM PARR S.p.A. VIA COSTA RTA, 15 24020 PARR (BG) ITALY TL. +39 035 705000 TLFAX +39 035

More information

P17 combined units LIMOGES Cedex Telephone : Fax : Cat. No.(s) : 566 XX XX XX XX

P17 combined units LIMOGES Cedex Telephone : Fax : Cat. No.(s) : 566 XX XX XX XX 8704 LIMOGES Cedex Telephone : + 33 0 06 87 87 - Fax : + 33 0 06 88 88 P17 combined units Cat. No.(s) : 66 XX - 72 XX - 77 XX - 89 XX CONTENTS Page 1. Description...1 2. Use...1 3. Range.......................

More information

Spec Sheet: IEC309 Panel Socket, Angled 16A IP67. Part Number

Spec Sheet: IEC309 Panel Socket, Angled 16A IP67. Part Number Spec Sheet: IEC309 Panel Socket, Angled 16A IP67 Part Numbers Part Number EU67SA316 EU67SA416 EU67SA516 Specification Description IEC309 16A 3 Pin panel socket, angled, IP67 IEC309 16A 4 Pin panel socket,

More information

ELECTRICAL PANELS. Chap.

ELECTRICAL PANELS. Chap. ELECTRICAL PANELS 360 Panel System Electrical Panels 360 Panel System Modular Panels DC Electric Panels AC Electric Panels AC/DC Electric Panels Aber Marine Panels IP 67 Watertight Panels Rotary Switch

More information

DATA SHEET 3PH-Battery-Backup-Distribution for 1x Sunny Island

DATA SHEET 3PH-Battery-Backup-Distribution for 1x Sunny Island 3PHBatteryBackupDistribution for 1x Sunny Island enwitecordernumber 10012549 Customerarticlenumber Type designation Match code Application Batteryinverter Grid structure BatteryBackupDistribution 1PH prepared

More information

WORKSHOP SPECIFICATIONS

WORKSHOP SPECIFICATIONS WORKSHOP SPECIFICATIONS DPX 3 160 & 250 MOULDED CASE CIRCUIT BREAKERS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DPX 3 RANGE Not only do DPX³ 160 and DPX 3 250 MCCBs provide

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Main current switches >180 A are realized in metal enclosures. Internationally approved.

Main current switches >180 A are realized in metal enclosures. Internationally approved. E X - M A I N C U R R E N T S W I T C H E S 10 A - 80 A (up to 630 A) CEAG main current switches in a number of versions can be protected against inadvertent switching on by our integrated locking facility

More information