METAL. consumer UNITS DOMESTIC CIRCUIT PROTECTION MANUFACTURED IN THE UK
|
|
- Melina Jacobs
- 6 years ago
- Views:
Transcription
1 METL consumer UNITS OMESTI IRUIT PROTETION MNUFTURE IN THE UK P O W E R E Y S P E I L I S T S
2 eyond the regulations Legrand s new range of metal consumer units does much more than meet the requirements of mendment 3 to the 17th Edition of the Wiring Regulations; it offers additional installer and user benefits that have been developed following extensive customer research. E SFE NOT SEEN With a range of surface, semi-flush and flush mounting versions to choose from, each consumer unit is finished in white RL 9003 (low smoke and fumes approved paint), which blends in seamlessly with modern living designs. Semi-flush mounted Semi-flush units can be mounted into any type of wall which means they can be installed in the most convenient location in the property.
3 Surface mounted. Flush mounted. PRT M OMPLINT Semi-flush and flush mounting units protrude less from the wall, making them the perfect solution when considering the requirements of Part M of the uilding Regulations (access to and use of buildings) which states that the switches should be between 1.35m to 1.45m the floor. t this height, the units are out of the reach of children yet accessible to adults, whether standing or sitting. 1
4 THERE s more TO SFETY THN MEETS THE EYE Rail positioned for maximum cablling space LE LMP Supplied with each unit, the cable clamp ensures incoming cables are secured to maintain a sound connection. 2 x ERTH LINKS Each part of the metal unit is earthed using two earth links which connect the back box to the front plate, and the front plate to the lid. Knockouts at bottom, top and back for cabling ease LOKLE LTH ll units are supplied with a lockable latch which ensures that the lid cannot be opened by an unauthorised person. (Padlock supplied separately). RY LINING K OX djustable fixing lugs allow fast installation of semi-flush units. Simply turn the lug 90 degrees and tighten the screw to secure the unit into place. 2
5 Earth link from back box to front plate For Ms, Rs and ROs see page 6. able clamp ensures incoming cables are secured Lockable option White RL 9003 ut-to-length busbar for flexible on-site configuration Earth link from front plate to lid oor opens downwards 3
6 metal consumer units selection charts NEW METL ONSUMER UNITS Meet the requirements of S 7671 : 2008 mendment 3 Regulation , conforms to S EN RL white colour Pre-galvanised steel for strength and rigidity oor opens downwards Supplied with incoming meter tail clamp Multiple knock-outs at the top, bottom and back Neutral and earth terminals with screws in backed-off position ut-to-length busbar Removable pan assembly Supplied with blank plates for 5 modules and label kit imensions p. 7-9 SURFE MOUNTING USTOM UIL MIN SWITH INOMER 63 main switch R INOMER m R UL R SPLIT LO 100 main switch 2 x m R HIGH INTEGRITY - UL R 100 main switch 2 x m R NO. OF VILLE WYS 2 available ways 4 available ways 6 available ways 8 available ways 10 available ways 12 available ways 14 available ways 16 available ways imensions p SEMI-FLUSH MOUNTING FLUSH MOUNTING UL R SPLIT LO 100 main switch 2 x m R HIGH INTEGRITY - UL R 100 main switch 2 x m R UL R SPLIT LO 100 main switch 2 x m R HIGH INTEGRITY - UL R 100 main switch 2 x m R NO. OF VILLE WYS NO. OF imensions p. 8 VILLE WYS imensions p available ways available ways available ways available ways RX 3 residential Ms and single module ROs p. 6 4
7 metal consumer units NEW imensions p. 7-9 Meet the requirements of S 7671 : 2008 mendment 3 Regulation , conforms to S EN RL white colour Pre-galvanised steel for strength and rigidity oor opens downwards Supplied with incoming meter tail clamp Multiple knock-outs at the top, bottom and back Neutral and earth terminals with screws in backed-off position ut-to-length busbar Removable pan assembly Supplied with blank plates for 5 modules and label kit Pack at. Nos. Surface mounting Pack at. Nos. Flush mounting ual R split load module unit (8 + 2 ways available) With 100 main switch and 2 x m R module unit ( ways available) With 100 main switch and 2 x m R High integrity - R split load with 2 unprotected ways module unit (8 + 2 ways available) With 100 main switch and 2 x m R module unit ( ways available) With 100 main switch and 2 x m R With incomer modules available With 63 main switch (2 ways available) modules available With m R (6 ways available) modules available With 80 30m R (10 ways available) ustom build llows several configurations and incomers (isolating switches, Rs, ROs, see p. 6) modules available modules available modules available Semi-flush mounting ual R split load module unit (8 + 2 ways available) With 100 main switch and 2 x m R module unit ( ways available) With 100 main switch and 2 x m R High integrity - R split load with 2 unprotected ways module unit (8 + 2 ways available) With 100 main switch and 2 x m R module unit ( ways available) With 100 main switch and 2 x m R ual R split load module unit (8 + 2 ways available) With 100 main switch and 2 x m R module unit ( ways available) With 100 main switch and 2 x m R High integrity - R split load with 2 unprotected ways module unit (8 + 2 ways available) With 100 main switch and 2 x m R module unit ( ways available) With 100 main switch and 2 x m R ccessories Incomer or dual tariff kit omprises : 1 flexible neutral (blue) lead 1 rigid neutral link Split load kit omprises : 1 flexible live (brown) lead 1 flexible neutral (blue) lead 2 rigid neutral links Split load dual tariff kit omprises : 1 flexible live (brown) lead 2 flexible neutral (blue) leads 2 rigid neutral links 1 neutral terminal Spare blank plate RL modules - white colour Spare blank plate RL module, separable by single or half modules Spare busbar prongs Spacing elements module Locking device for Ms and Rs Locking attachment for Ø 4 mm and Ø 6 mm padlocks Padlock Padlock Ø 4 m Spare terminal block hole Self-adhesive label holder Width : 16 mm Width available for marking : 12 mm Length 530 mm (24 modules)
8 protection and control devices Pack at. Nos. RX 3 residential Ms reaking capacity : 6000 to S EN Single pole - 230/400 V± curve curve Nominal rating Number of (In) 17 5 mm modules NEW X 3 Ms reaking capacity : 6000 to S EN Single pole - 230/400 V± curve curve Nominal rating Number of (In) 17 5 mm modules ROs (combined M/R) - Single module reaking capacity : 10 k to S EN R type conform to S EN Terminal capacity : rigid conductor 35 mm 2 flexible conductor 25 mm 2 Single pole and neutral V± curve Nominal rating Number of (In) 17 5 mm modules 30 m Pack at. Nos. RX 3 residual current devices (Rs) onform to S EN Terminal capacity : rigid conductor 35 mm 2 flexible conductor 25 mm 2 ouble pole 230 V± Type Nominal rating Number of (In) 17 5 mm modules 30 m m X 3 isolating switches onform to S EN , S EN Usage : 22 according to S EN Red handle ouble break contacts, padlockable 50 mm 2 capacity shielded terminals Number of 17 5 mm modules double pole double pole 2 X 3 contactor with 230 V± coil onforms to S EN ouble pole (L + N) 250 V± 230 V± coil circuit Type of Number of I max. contact 17 5 mm modules 230 V N/O 1 For other contactors, see current Industrial and Power Protection catalogue ell transformers d onform to S EN Supplied with label holder Protected against overloads and short circuits Power to 8 V-12 V or 24 V access control devices such as bells and chimes Possibility for supply busbars to run through (at. Nos /91) Number Secondary (V) Rating () Power (V) of 17 5 mm modules 230 V / 8 V V± V V / 12 V - 8 V /8 V± 0 66/1 8 V V / 24 V - 12 V /12 V± 1/1 5 24/18 V 4 6
9 metal consumer units surface mounting n Surface mounting Overall dimensions (mm) n 12 module unit ack box fixing centres and cable entries (mm) Modules (mm) (mm) (mm) n 4 module unit ack box fixing centres and cable entries (mm) 240 n 16 module unit ack box fixing centres and cable entries (mm) Ø Ø module unit only n 8 module unit ack box fixing centres and cable entries (mm) n 22 module unit ack box fixing centres and cable entries (mm) 4 Ø Ø9 8 / 12 / 16 / 22 module units Number of cable entries Modules Ø20 mm Ø25 mm Ø32 mm 100 x 50 mm ll dimensions (mm) are nominal Number of cable entries Modules Ø20 mm Ø25 mm Ø32 mm 100 x 50 mm
10 metal consumer units semi-flush mounting n Semi-flush mounting Overall dimensions (mm) n 16 module unit ack box cable entries (mm) Modules (mm) (mm) (mm) (mm) n 22 module unit ack box cable entries (mm) n 16 and 22 module unit ack box fixing cutouts (mm) 220 Modules (mm) Number of cable entries Modules Ø20 mm Ø25 mm Ø32 mm 100 x 50 mm ll dimensions (mm) are nominal 8
11 metal consumer units flush mounting n Flush mounting Overall dimensions (mm) n 16 module unit able entries and fixings (mm) x Ø7.5 Knock-outs x Ø7.5 Knock-outs (2 x left & right sides) Modules (mm) (mm) (mm) (mm) n 16 and 22 module unit ack box fixing cutouts or aperture sizes (mm) n 22 module unit able entries and fixings (mm) x Ø7.5 Knock-outs E F 225 E F E 4 x Ø7.5 Knock-outs (2 x left & right sides) F Modules (mm) E F E = ase fixing method F = Side fixing method Screw fixings not supplied Use suitable fixings with large head or penny washers Number of cable entries Modules Ø20 mm Ø25 mm Ø32 mm 100 x 50 mm ll dimensions (mm) are nominal 9
12 FST, RELILE ONNETIONS For commercial and residential applications in both new and existing installations, Tenby Rapid lamp Ultra creates earthing connections with a simple fixing method that makes fitting them in hard to reach areas easier than ever. The unique twist fixing method is up to 5 times faster when compared with traditional clamps. So for mains incomer pipes, boiler replacement, special locations or supplementary bonding in pre-17th Edition installations, earthing is a whole lot easier with Tenby! 10
13 Tenby Rapid lamp Ultra earth clamps Tenby Rapid lamp Ultra earth clamps E E15/ onform to S 951 : 2009 vailable in three sizes Suitable for dry, non corrosive atmospheres and corrosive or humid conditions Resistance of incandescent wire 960 Resistivity of 0. 4 mω olour : grey Polyamide Safe, intuitive 1/4 turn mounting ensuring an excellent, lasting equipotential link E16/3 onform to S 951 : 2009 vailable in three types : Red (E14) for dry, non corrosive atmospheres lue (E15) for corrosive or humid conditions Green (E16) for corrosive or humid conditions, large earth conductors 5 standard band lengths to suit pipe Ø of mm, mm, mm, up to 100 mm and up to 150 mm Pack at. Nos. Earth clamps for all conditions Pack at. Nos. Earth clamps for dry conditions Terminal size : ( mm 2 ) Maximum earth conductor 1 x 10 mm 2 Pipe Ø onnection cross-section Ø min. (mm) Ø max. (mm) min. (mm 2 ) max. (mm 2 ) Terminal size : ( mm 2 ) Maximum earth conductor 1 x 10 mm 2 20 E14 For pipe Ø mm 20 E14/2 For pipe Ø mm 20 E14/3 For pipe Ø mm Earth clamps for all conditions Terminal size : ( mm 2 ) Maximum earth conductor 1 x 10 mm 2 20 E15 For pipe Ø mm 20 E15/2 For pipe Ø mm 20 E15/3 For pipe Ø mm 20 E15/4 For pipe Ø up to 100 mm 20 E15/6 For pipe Ø up to 150 mm Terminal size : E ( mm 2 ) Maximum earth conductor 2 x 16 mm 2 20 E16 For pipe Ø mm 20 E16/2 For pipe Ø mm 20 E16/3 For pipe Ø mm 11
14 ross-reference table ONSUMER UNITS, MS N ESSORIES Range escription Old at. No. at. No. ccessory Spare lank Plate ccessory Lockable brackets For 16 Module Units - Semi-Flush Mounting ccessory Lockable brackets For 22 Module Units - Semi-Flush Mounting ccessory Lockable brackets For 16 Module Units - Surface Mounting ccessory Lockable brackets For 22 Module Units - Surface Mounting onsumer Unit 16 Module ustom uild onsumer Unit - Surface Mounting onsumer Unit 22 Module ustom uild onsumer Unit - Surface Mounting onsumer Unit 16 Module ual R Split Load onsumer Unit - Surface Mounting onsumer Unit 22 Module ual R Split Load onsumer Unit - Surface Mounting onsumer Unit 8 Module 100 MS onsumer Unit - Surface Mounting onsumer Unit 12 Module 100 MS onsumer Unit - Surface Mounting onsumer Unit 8 Module ustom uild onsumer Unit - Surface Mounting onsumer Unit 12 Module ustom uild onsumer Unit - Surface Mounting onsumer Unit 16 Module ual R Split Load onsumer Unit - Surface Mounting onsumer Unit 22 Module ual R Split Load onsumer Unit - Surface Mounting onsumer Unit 8 Module 100 MS onsumer Unit - Surface Mounting onsumer Unit 12 Module 100 MS onsumer Unit - Surface Mounting onsumer Unit 8 Module ustom uild onsumer Unit - Surface Mounting onsumer Unit 12 Module ustom uild onsumer Unit - Surface Mounting onsumer Unit 4 Module 63 MS onsumer Unit - Surface Mounting onsumer Unit 8 Module m R onsumer Unit - Surface Mounting onsumer Unit 12 Module m R onsumer Unit - Surface Mounting onsumer Unit 16 Module 100 MS onsumer Unit - Surface Mounting onsumer Unit 22 Module 100 MS onsumer Unit - Surface Mounting onsumer Unit 4 Module ustom uild onsumer Unit - Surface Mounting onsumer Unit 16 Module High Integrity R Split Load onsumer Unit - Surface Mounting onsumer Unit 22 Module High Integrity R Split Load onsumer Unit - Surface Mounting onsumer Unit 22 Module ual R Split Load onsumer Unit - Semi-Flush Mounting onsumer Unit 16 Module ual R Split Load onsumer Unit - Semi-Flush Mounting onsumer Unit 16 Module High Integrity R Split Load onsumer Unit - Semi-Flush Mounting N onsumer Unit 22 Module High Integrity R Split Load onsumer Unit - Semi-Flush Mounting N onsumer Unit 16 Module ual R Split Load onsumer Unit - Flush Mounting N onsumer Unit 22 Module ual R Split Load onsumer Unit - Flush Mounting N onsumer Unit 16 Module High Integrity R Split Load onsumer Unit - Flush Mounting N onsumer Unit 22 Module High Integrity R Split Load onsumer Unit - Flush Mounting N M RX3 6 SP Type 6 k M M RX3 10 SP Type 6 k M M RX3 16 SP Type 6 k M M RX3 20 SP Type 6 k M M RX3 25 SP Type 6 k M M RX3 32 SP Type 6 k M M RX3 40 SP Type 6 k M M RX3 50 SP Type 6 k M M RX3 63 SP Type 6 k M M RX3 6 SP Type 6 k M M RX3 10 SP Type 6 k M M RX3 16 SP Type 6 k M M RX3 20 SP Type 6 k M M RX3 25 SP Type 6 k M M RX3 32 SP Type 6 k M M RX3 40 SP Type 6 k M M RX3 50 SP Type 6 k M M RX3 63 SP Type 6 k M
15
16 ontact details United Kingdom Great King Street North, irmingham, 19 2LF ustomer Services: Tel: +44 (0) Fax: +44 (0) Quotations and Technical Support: Tel: +44 (0) Fax: +44 (0) Republic of Ireland: Tel: Fax: Follow US T Metal consumer units K Head office (UK and Ireland): Legrand Electric Limited Great King Street North, irmingham, 19 2LF Tel: +44 (0) Fax: +44 (0) Website: In accordance with its policy of continuous improvement, the ompany reserves the right to change specifications and designs without notice. ll illustrations, descriptions, dimensions and weights in this catalogue are for guidance and cannot be held binding on the ompany. ll contents and design presentation included in this publication are Legrand Electric Limited. ll rights reserved This document is printed on sustainably sourced paper. Please recycle. The Legrand logo is a registered trademark of the Legrand group of companies.
Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.
Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE Distributor : LEGRAND ELECTRIC LIMITED Great King Street North, Birmingham, B19 2LF Tel : 0870 608 9000 Fax : 0870 608 9004 CONSUMER UNIT BRO.10.05.??K
More informationGreater protection UNDERSTANDING THE 17TH EDITION CONSUMER UNITS / PRODUCT GUIDE
Greater protection UNDERSTANDING THE 17TH EDITION CONSUMER UNITS / PRODUCT GUIDE Summary of changes Simplifying the 17 th Edition Understanding new regulations is never easy... that s why we ve tried to
More informationZucchini busbar ZUCCHINI DISTRIBUTION FUSE BOARD TAP-OFF
Zucchini busbar ZUCCHINI DISTRIBUTION FUSE BOARD TAP-OFF Global strength built on local knowledge Legrand is the global specialist in electrical and digital building infrastructures. Innovation is the
More informationPractical and completely safe
FUSE RRIERS >>> Practical and completely safe Isolating fuse carriers 058 06 058 28 Dimensions (p. 0) onform to standard IE 60269-2/2. and to NF 63-2. Isolators conform to IE 60947-3. Icc: - 20 k with
More informationVOLUME 1 IKH=N<M ppp'^lk^gm^kikbl^'\hf
VOLUM 1 introduction Welcome to SR nterprise Ltd catalogue volume 1. SR is a brand new company with many years previous experience in the industry. We are a young and innovate company sourcing quality
More informationNew Plexo 3, all the space you need
New Plexo 3, all the space you need IP 65 WEATHERPROOF ENCLOSURES No constraints on your wiring: plenty of space inside the box 2 PLEXO 3 - PLENTY OF SPACE FOR YOUR CONVENIENCE A wide range of enclosures
More informationworkshop specifications Plexo³ IP 65 cabinets
workshop specifications Plexo³ IP 65 THE GLOBL SPECILIST IN ELECTRICL ND DIGITL BUILDING INFRSTRUCTURES With their IP 65 weatherproof protection and optimised dimensions, Plexo³, from 2 to 4 x 18 modules,
More informationXL 3 -N SimPly, EfficiEnt And SAfE. 3 - PHASE distribution boards up to 250 A
XL 3 -N 125 250 SimPly, EfficiEnt And SAfE 3 - PHASE distribution boards up to 250 A the global specialist in ElEctricAl And digital building infrastructures Xl 3 -n Comprehensive and reliable range for
More informationConsumer unit solutions to meet the requirements of the new 17th edition amendment 3 regulations
MEMT Memera full metal consumer units and protective devices Consumer unit solutions to meet the requirements of the new 17th edition amendment 3 regulations Memera full metal consumer units and protective
More informationEquipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module
transformers and buzzers and bells socket outlets and special supports 042 25 042 52 041 07 042 80 042 85 Pack Cat.Nos Bell transformers dconform to IEC / EN 61558-2-8 Protected against overloads and short
More information19" XL VDI wall mounting cabinets and accessories
19" XL VDI wall mounting cabinets and accessories 340 36 340 38 340 49 340 52 332 25 331 36 Technical characteristics (p. 814-815) IP 20 - IK 08 Equipped with: 1 reversible curved door made of screen-printed
More informationSynergy WIRING ACCESSORIES / PRODUCT GUIDE
form and function in perfect harmony WIRING ACCESSORIES / PRODUCT GUIDE Contents The philosophy 04 Packed with features 06 True functionality 08 The range at a glance 10 Synergy function selection chart
More informationDomae. The right solution for distribution boards
Domae The right solution for distribution boards Guaranteed quality and adapted solutions Domae : SIRIM approved The quality marks prove product conformity to their reference standard. They guarantee:
More informationHypra IP 66/67-55 plastic plugs and sockets LV 16/32/63/125 A
ypra P 66/67- plastic plugs and sockets LV 16/32/63/12 P 66/67- - LV 16, 32, 63 N 12 onform to : S N 609-1, S 609-2, 609-1 and 609-2 P according to S N 6029 and 6029 09 Self-extinguishing : 80 for insulated
More informationStarfix TM ferrules and crimping tools
Starfix ferrules and crimping tool 3 wire marking Nylbloc auto screwless mounting connectors Nylbloc screw terminal strips Starfix TM ferrules and crimping tools 376 50 376 66 376 77 377 64 376 87 376
More informationcavity floor service outlet boxes
Reversible lid 2 cable outlets with sponge foam to prevent ingress Rapid fit /remove mechanism adjusts for flooring thickness Durabable ABS trim and lid surround Full range of power and data module plates
More informationDX³ RCCBs - ID 4P up to 100 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationFeatures EN/IEC Applications
PO Modular polyester boxes nsulated boxes Standards eatures ntro N/ 639- N/ 6059 N/ 608 pprovals - oxes with polyester cover: types 3, 3R,,, 6, 6P, and 3 - oxes with polycarbonate cover: types 3, 3R,,,
More informationCABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
O S O O CABINETS AND ENCLOSURES XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES II With its extensive ranges, the Legrand offer meets your quality standards and
More informationControl and Automation
onsumer & ndustrial Power Protection ontrol and utomation or industrial applications.03 imagination at work Plug-in relays and uxiliary contactors Motor protection devices ontactors and Thermal overload
More informationNew DX 3 High rating & breaking capacity
New High rating & breaking capacity a new range OF MOduLar CirCuiT BrEakErs up TO 125 a T new dx³ MCBs AN ENHANCED range for HIgH-pErforMANCE INstALLAtIoNs DX³ : the new Legrand MCBs with dx³, Legrand
More informationResidential and light commercial. invicta. panelboards
Residential and light commercial invicta panelboards Your simple energy distribution solution As an industry leader in power distribution, we strive to create innovative products that make installations
More informationApprovals (p. 906) 0 371 61 0 371 63 0 371 64 0 371 66 0 371 69 0 371 68 0 371 00 0 371 08 0 371 20 Connecting (p. 300) 1 connection - 1 entry/1 outlet ELECTRICAL FUNCTION TERMINAL BLOCKS INSULATION EQUIPOTENTIAL
More informationAThink future. Switch to green. XBoard Consumer Units. stylish and easy to fit.
www.moeller.co.uk XBoard Consumer Units stylish and easy to fit XBoard Consumer Units XPole Miniature Circuit Breakers, RCDs and RCBOs A + B Type Distribution Boards Mini Panel Boards Panel Boards Product
More informationHypra and P 17 industrial sockets
[ INUSTRIL SOKTS ] Products and systems ypra and P 17 industrial sockets 2 ranges cover 3 levels of weatherproofing: IP 44, IP 66/67 and IP 66/67-55: ypra is recommended for harsh environments (dust, water
More informationDOMINO Series surface mounting IP55
Series surface mounting IP55 SERIES CONSUMER UNITS SURFACE MOUNTING VERSION - IP55 REFERENCE STANDARDS International standard IEC 60670 (989) and the Modification (994) Part : General requirements for
More informationTX³ RCCBs 2P up to 100 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationDPX moulded case circuit breakers
BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.
More informationNEW TX³ RANGE PROTECTION YOU CAN RELY ON
TX³ NEW RANGE TRUSTED PROTECTION FOR YOUR INSTALLATIONS GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES NEW TX³ RANGE PROTECTION YOU CAN RELY ON Designed to meet the requirements of
More information503 Series Solenoid Pilot Actuated Valves
Solenoid Pilot ctuated Valves Offered by: Specialists in Valves, ontrols, Pneumatics, Fluid Measurement Phone: (203) 261-6711 www.okcautomation.com 5 Ported, 2 and 3 position, 4-way, Spool & Sleeve and
More information19" XL VDI wall mounting cabinets and accessories
19" XL VI wall mounting cabinets and accessories 340 36 340 38 340 49 340 52 332 25 Pack Technical characteristics (p. 898-899) IP 20 - IK 08 Equipped with: 1 reversible curved door made of screen-printed
More informationPushbuttons B3. Options and ordering codes. Exploded view. BS 3. Green
Pushbuttons 3 IP65 protection Opaque or illuminated Metal or lack bezels Snap-on contact blocks Colour coded contacts Pushbutton stations International approvals including UL and CS Options and ordering
More informationSwitch Disconnectors
Switch Disconnectors Reversible terminals allow the same switch body to be used in both front & rear mount applications 25A - 32A - 50A - 63A - 80A - A versions available Neutral pole, additional poles
More informationNew VikingTM 3, the innovation
New VikingTM 3, the innovation Screw or automatic spring connection A new range, born of research & EXPERIENCE INDEX Screw connection... 2 Automatic spring connection... 4 Common accessories... 6 Selection
More informationAssembly kits (501 Series/502 Series/503 Series) 25 Pin Sub-D Connector Kit
50, 502 and 50 series ssembly kits (50 Series//) 25 Pin Sub- onnector Kit Ø5.5 25 Pin Sub- onnector Kit P5994284400 P59942844002 25 PIN SU- SSMLY WITHOUT IN RIL 25 PIN SU- SSMLY WITH IN RIL G N2522U02MS
More information1SLC811001B0202. Wiring ducts. the widest choice for greater convenience and speed at work
1SLC811001B0202 Wiring ducts the widest choice for greater convenience and speed at work No application is beyond its reach All the space cables need. Less complicated work brings installers and panel
More informationCOMPLETE SOLUTIONS FOR POWER PROTECTION
COMPLETE SOLUTIONS FOR POWER PROTECTION GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Modular protection P. 8 RX 3 MCBs 63 A 4500 & 6000 P. 18 DX 3 -IS isolating switches P. 9 RX
More informationCABLE MANAGEMENT SOLUTIONS CATALOGUE2003/04 A COMPLETE CABLE MANAGEMENT SOLUTION FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS.
CLE MNGEMENT SOLUTIONS CTLOGUE2003/04 COMPLETE CLE MNGEMENT SOLUTION FOR COMMERCIL ND INDUSTRIL PPLICTIONS www.legrand.co.uk FSTRCK F31 FSTRCK F31 SYSTEM STEEL WIRE CLE TRY Legrand With a large range of
More informationViking 3 - Screw connection Disconnect terminal blocks
87045 LIMOGES Cedex Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Viking 3 - Screw connection 1. General features... 1 2. Range...2 3. Standards... 2 4. Technical features... 3 5. Dimensions...
More informationSafety Lampholders and Pendants
Safety Lampholders and Pendants Safety products are designed to make life easy for you. When the lamp is removed from the lamp holder body the power is automatically disconnected at the contacts - ensuring
More informationLow Voltage Assemblies
xboard Distribution Boards xboard panelboards (xdb) Compact and versatile, xdb panelboards deliver an efficient energy distribution system in commercial and light industrial applications. Available in
More informationXL Distribution enclosures WORKSHOP SPECIFICATIONS
800 Distribution enclosures WORKSHOP SPECIFICATIONS With its extensive ranges, the Legrand offer meets your quality standards and provides real freedom and simplicity of installation together with acknowledged
More informationXL³ 400 metal distribution cabinets, free-standing enclosures and cable compartments
87045 LIMOGES Cedex Telephone : 05 55 06 87 87 Fax : 05 55 06 88 88 XL³ 400 metal distribution cabinets, free-standing Cat. No(s) : 20103/04/05/06/07/08/18/19/23/ CONTENTS PAGE 1. General characteristics...
More informationSelection Information Molded Case Circuit Breakers
Selection Information Molded ase ircuit reakers lass 500, 600, 800 100 rame 100 -rame IRUIT RKRS 3 ircuit reaker Type (240 V) H Hb H I Y Number of 1, 2, 3 1 2, 3 1 1 2, 3 2, 3 1 urrent Range 15 100 15
More informationSingle Socket and Horizontal Metering
G nergy onnections Single Socket and orizontal Metering T Approved Single Socket Metering T Approved Application Information G s Single Socket Metering products are designed for residential use. They are
More informationFD frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FD63 FD160. Trip Unit. Rated Current (A) FD63 (2,3 & 4 pole)
frame reaking capacities 2, 3 and types Single pole types Icu 0/415V in k eff. Type 18 18 S 36 36 N H L 1 1 Icu 2/2V in k eff. N H Protection LTM Line thermal magnetic protection LTM Selective thermal
More informationINFRESCO-S-4kW X20034 Issue: 7
INFRESCO-S-4kW X20034 Issue: 7 User Manual Date: 17/01/17 Page: 1 of 7 KEY FEATURES Extends lamp Life. Ideal for controlling up to 2 x 2kW lamps. Soft-start/zero-voltage switch-off. Low-cost. Easy to install.
More informationBharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT
An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli 620014, TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT ENQUIRY NOTICE INVITING TENDER Phone:
More informationxboard safety, reliability effectively combining and performance safety, reliability and performance in commercial and industrial applications
xboard commercial and industrial panelboards xboard effectively combining safety, reliability and performance safety, reliability and performance in commercial and industrial applications NEW xboard (xdb)
More informationP 17 Tempra IP 44 - LV 16 and 32 A sockets, plugs, mobile sockets, appliance inlets
P 17 Tempra IP 44 - LV 16 and 32 sockets, plugs, mobile sockets, appliance inlets www.klinkmann.com 555 53 573 54 574 34 575 14 575 84 Technical characteristics (p. 389) Pack at.nos Surface mounting sockets
More informationFD frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FD160. Trip Unit. Rated Current (A)
frame reaking capacities 2, 3 and 4 pole types Single pole types Icu 0/415V in k eff. Type 18 S 36 N H L 1 Icu 230/2V in k eff. N H Protection Order odes LTM Line thermal magnetic protection LTM Selective
More informationMOTOR CONNECTIONS MOTOR-DECONTACTOR & INDUSTRIAL PLUGS & SOCKET-OUTLETS. hyconelec.co.za MARECHAL TECHNOLOGY
MOTOR CONNECTIONS MOTOR-DECONTACTOR & INDUSTRIAL PLUGS & SOCKET-OUTLETS hyconelec.co.za MARECHAL TECHNOLOGY SAFE AND RELIABLE ELECTRICAL CONNECTIONS FOR YOUR MOTORS. MARECHAL ELECTRIC offers a range of
More informationPVC-LINK. High Impact, Complete Flexibility. Product Catalogue Cable Management System Distribution Enclosure & Weatherproof Boxes
PVC-LINK High Impact, Complete Flexibility Product Catalogue Cable Management System Distribution Enclosure & Weatherproof oxes PVC-LINK High Impact,Complete Flexibility COMPLINCE TO STNDRD PVC-LINK is
More informationNo. 5 Moment Load Carriages
This data sheet interacts with PRT2 atalogue 48-49 HepcoMotion No. 5 Moment Load arriages HepcoMotion moment load carriage systems provide extra support and rigidity in applications where high downwards
More informationLASERMET MINIATURE LED SIGN POWER AND SWITCH UNIT. Installation Instructions
LASERMET MINIATURE LED SIGN POWER AND SWITCH UNIT Installation Instructions PS-LEDS-1W PS-LEDS-RG 00597-53-000 Issue 2 23 August 2010 Introduction The Miniature LED Sign Power and Switch Unit is intended
More informationDX³ 4-pole RCBO 6000 A/10 ka
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationKD Fittings. Product range:
K Fittings Product range: ll-threads rackets rass Heads ams & olts ross owels Flush Mounts Inserts Insex Screws Maxi Luna Fittings Modeez Fasteners Panel onnectors Screws Stretcher Plates Tee Nuts Unita
More informationVarious rocker colours. Illuminated or non-illuminated ELECTRICAL SPECIFICATIONS
00 series istinctive features and specifications Three rocker shapes : plain, Vshaped or concave Various rocker colours Frame with protection guard on 00LP models Illuminated or nonilluminated UL, CSA,
More informationInstallation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.
Description Marking The ANTARES ExtSet makes it possible to distribute the Remote I/O ANTARES modules of an explosion-protected Remote I/O system ANTARES among a maximum of 4 metal mounting rails. For
More informationModern Soft Edged White Moulded Wiring Accessories
Modern Soft Edged White Moulded Wiring Accessories 10 amp Plate Switches Dimmers Push n / ff & No De-"ating 20 amp DP Switches 45 amp DP Switches 13 amp Socket utlets "ound Pin Socket utlets Fused Connection
More information7000 SERIES ROCKER AND PADDLE SWITCHES Overview
Overview 7 SERIES Number of poles Terminals 3 Single pole 4 Double pole onsult factory for three and four pole models. Blank W WW Y } Y4 } Y6 } Y7 } Z Solder lugs or straight P depending on model Right
More informationFUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A
Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved
More informationFUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems
FUSERBLOC CD The universal Fuse Combination Switch FROM 20 TO 1250 A SOCOMEC GROUP SWITCHING PROTECTION & UPS Industrial Switching & Protection Systems SWITCHING FUSERBLOC CD THE UNIVERSAL FUSE COMBINATION
More informationYour Global Source for Today s Most Popular Solenoid Valves
lcon Solenoid Valves Your Global Source for Today s Most Popular Solenoid Valves lcon Solenoid Valves Your Global Source for Today s Most Popular Solenoid Valves lcon Solenoid Valves, a division of International
More informationFE Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FE160 FE250. Protection. Trip Unit. Rated Current (A)
rame reaking capacities Icu 0/415V in k eff. Type V 36 N H L 1 1 Protection LTM Line thermal magnetic protection LTM Selective thermal magnetic protection TM enerator thermal magnetic protection Mag reak
More informationFloor boxes... choice, flexibility and easy installation
Floor boxes... choice, flexibility and easy installation 2, 3 and 4 compartment raised access loor boxes and slab boxes offer complete versatility. Floor boxes are available pre-wired with power track
More informationNEMA Contactors & Starters A200
March 007 NM ontactors & Starters 00 ontactors Non-reversing and Reversing -7 ontents escription Page ontactors Non-reversing and Reversing............ -7 Product escription Sizes 00 4............ -7 Product
More information18 th Edition. Overload Protection of RCCBs and Switches within Consumer Units
18 th Edition Overload Protection of RCCBs and Switches within Consumer Units Contents Executive Summary 3 Introduction 4 Where the changes to the regulations originate 4 Pre 18 th Edition approach to
More informationFlush mounting enclosures. Pragma UP
Flush mounting enclosures Presentation Flush mounting enclosures The appearance of this enclosure, its mechanical strength and its level of electrical safety make it a product fully suitable for residential
More informationPDL s DBF AND DBS SERIES DISTRIBUTION BOARDS
PDL s DBF AND DBS SERIES DISTRIBUTION BOARDS FEATURES Robust, durable construction Unique double doors open 180 with minimum projection Light grey colour standard, can be painted to suit décor re quirements
More informationWeatherproof grilles
Weatherproof grilles Weatherproof grilles PPLITION Weatherproof grilles prevent rainwater from entering inlets and outlets in building façades either as part of an HV system or for natural ventilation
More informationPhase + Neutral, neutral on right side
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34
More information125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request
125 to 4000 A sirco_353_a_1_cat sirco_296_a_1_cat sirco_300_b switches are manually operated or motorised multipolar load break switches. They break on and off under load and provide safety isolation for
More informationRX 3 MCB 4500 A Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationPack Cat. Nos. Single pole push switches gang 2 way push switch gang 2 way push switch marked PRESS gang 2 way
white 7300 00 7300 02 7300 07 7301 07 7301 33 7300 06 7300 08 7300 09 Terminal screws captive and backed off ready for cabling Surface mounting boxes (see p. 112) Pack Cat. os. Single pole plate switches
More informationEfficor* Intro. Conformity to standards. Ambient conditions. Climatic resistance (IEC 68-2) Approvals/Marking. Mounting positions
fficor* onformity to standards /N 60947-1 04 /N 60947-4-1 UL508 /N 60947-5-1 UL486 /N 60947-5-4 S22- N500 N 16 101/102 N50012 N50005 pprovals/marking mbient conditions Storage temperature -55º to +80º
More informationic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi
Contents Miniature circuit breakers ic60n miniature circuit breakers 6kA, C curve, 6-63A ic60h miniature circuit breakers 10kA, C curve, 6-63A ic60n miniature circuit breakers 6kA, B curve, 6-63A ic60h
More informationMRTS Trip Circuit Supervision Relay
MRTS Trip ircuit Supervision Relay P& Engineering elle Vue Works oundary Street Manchester M NG Tel: 00 Fax: 00 /0/9 0 MRTS 0/9G ] Summary The MRTS relay is of a standard modular construction of the drawout
More informationPolySafe. Insulated wall mounting cabinets. Intro. Multipurpose polyester cabinets. Features. Standards. Approvals. Ambient conditions B.
Multipurpose polyester cabinets Standards eatures N/ 60529 N/ 61439-2 N/ 62208 N/ 62262 pprovals - abinets with one door: type 3, 3R, 3S, 4, 4, 12, 12K and 13 - abinets with two doors: type 3, 3R, 3S,
More informationDX³ RCBO 4500/6 ka Phase + Neutral, neutral on left
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...
More informationl Suitable for most residential, commercial and light industrial applications
538 Consumer Units and Enclosures Standards and approvals All Sentry consumer units are designed to fully comply with the requirements of BS EN 60439-3. Weatherproof enclosures are designed to fully comply
More informationPrisma Plus G enclosures IP30, IP31, IP43 enclosures
Prisma Plus G IP30, IP31, IP43 Prisma Plus G IP30, IP31, IP43 Presentation For safe and upgradeable electrical switchboards > Safety of people and property > Continuity of service > Optimization and upgradeability
More informationRESIDENTIAL BUILDINGS & HOTEL EQUIPMENT
RESIDENTIAL BUILDINGS & HOTEL EQUIPMENT Plexo flush-mounting complete IP 55 Plexo surface-mounting complete IP 55 Plexo mechanisms IP 55 for flush or surface-mounting Plexo surface-mounting boxes and support
More information, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationMR - MEDIUM RATING A
88 MR - MEDIUM RATING 160-1000A SECTION CONTENTS 90 General features 96 Advantages 100 Illustrated contents MR MEDIUM RATING 102 Trunking components 110 Feed units and end covers 113 Tap-off boxes 118
More informationGeneral Specifications
Series HB Subminiature Pushbuttons General Specifications Electrical apacity (Resistive Load) Power Level (silver): 0.1A maximum @ 30V A/ Other Ratings ontact Resistance: 50 milliohms maximum Insulation
More informationPhase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationAquatec Ocean Family. Ocean Family. Aquatec
The Ocean series of shower commode chairs offers a flexible, modular solution for a wide range of clients. The range consists of transit, self-propel, tilt in space as well as powered tilt and recline
More informationPlexo 3 weatherproof cabinets
87045 LIMOGES Cedex Telephone: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Plexo 3 weatherproof cabinets CONTENTS PAGES 1. Description, use.....1 2. Range, equivalence table...1 3. Overall dimensions...2
More informationadaptable, reliable underfloor power
adaptable, POWERTRACK reliable adaptable, reliable underfloor power 6 THE INDUSTRY STANDARD IN UNDERFLOOR POWER Electrak powertrack / underfloor busbar is perfect for cavity floor installations. With minimal
More informationInstallation Enclosures
Meter Boxes SMB's To house a single phase kilowatt hour meter * Standard kwh meter mounting * Surface or semi-flush installation * Square or triangular securing screw * Stand off for circuit breaker *
More informationType 4 Panel Enclosures
Ground-Mount Enclosures Type 4 Free-Standing ata Sheet Finish Wash and phosphate undercoat NSI 61 gray polyester powder finish pplication Houses electrical controls and instruments Easy access panels or
More informationLB - LIGHTING BUSWAY 25-40A
16 LB - LIGHTING BUSWAY 25-40A LIGHTING BUSWAY SECTION CONTENTS 18 General features 24 Trunking components: 2 and 4 conductors elements 28 Trunking components: 6 conductors elements 30 Plugs 33 Fixing
More informationBussmann series IEC cylindrical fuses
IE and ritish Standard fuses 5 ontents ussmann series IE cylindrical fuses Section page escription Fuses S Type P and fuses (N, S and PON) HR Form II lass fuses (GL) 3 HRI industrial ceramic body fuses
More informationDX³ RCBO 6000 A Phase + Neutral, neutral right side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX³ RCBO 6000 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1
More informationRipac Vario-Module System Enclosure
Ripac Vario-Module System Enclosure The Riase instrument case impresses with its modern design and high functionality. Particular features include the numerous colour variants and the all-metal enclosure
More informationP17. Tempra PRO. a range you can rely on CATALOGUE PAGES INSIDE. GLOBAL SPECIALIST in electrical and digital building infrastructures
P17 Tempra PRO a range you can rely on -> GLOBAL SPECIALIST in electrical and digital building infrastructures CATALOGUE PAGES INSIDE P17 TEMPRA PRO, suitable for all the P17 tempra Pro range incorporates
More informationDNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation
More informationQO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories
QO and Miniature ircuit reakers QO ircuit reaker ccessories lass 1130 / Refer to atalog 0730T9801 IRUIT RKRS ccessories for Use with QO and QO Miniature ircuit reakers Handle ttachments escription at.
More informationMODE - Multiple Occupancy Distribution Equipment Selection guide for low voltage indoor distribution up to 500A
MODE - Multiple Occupancy Distribution Equipment Selection guide for low voltage indoor distribution up to 500A MODE - Multiple Occupancy Distribution Equipment Contents 4 MODE range: introduction 5 MODE
More information