25000, 4/2 Direct solenoid actuated poppet valves
|
|
- Theodora Reynolds
- 6 years ago
- Views:
Transcription
1 > > Port size: /4, /2 > > Working from 0 bar up > > Suited for outdoor installation > > Suitable for vacuum range down mbar l/s > > : 65, Ex em, Ex d TEX approved (see solenoid table) Technical features Medium: For neutral gaseous and liquid fluids Operation: Solenoid, directly controlled Operating pressure: 25 bar (362 psi) max. Nominal size: mm Port size: /4... /2 Mounting position: Optional, preferably vertical Flow direction: Fixed : M20x,5, /2 NPT mbient/ temperature: ( F) Solenoid operators: see table epending on solenoid system. ir supply must be dry enough to avoid ice formation at temperatures below +2 (+35 F). For outdoor installations must be protected all s against the penetration of moisture and a solenoid with 66 protection must be used! Materials: Housing: rass (Ms 58) Inner parts: rass or stainless steel.404 (430 F) Seat seal: NR Technical data Symbol Port size Solenoid group Nominal Size (mm) Operating pressure min. max. (bar) (bar) Materials Valve- Housing Seat seal kv-value (v (US) = kv x,2 (kg) imensions 2 3 /4 30, rass NR 0,5 2, /2 30, rass NR 0,8 3, /2 38, rass NR 0,9 4, *) When ordering please indicate solenoid, voltage and current type (frequency). No. *) without notice, the specifications given in this document. ( e) 205 Norgren mbh en
2 Solenoid operators (27) Solenoids group 30,5 (m ) (m ) 2, (with (TEX-ategory) mbient/ ( ) ircuit M20 x,5, , (with M20 x,5, , (with II 2 Ex e mb II T4/ T5 b II 2 Ex tb III T20 b 65 T4: T5: M20 x,5 2, , (with II 2 Ex e mb II T4/ T5 b II 2 Ex tb III T20 b 65 T4: T5: M20 x,5 2, version on request Solenoids group 30,5 (m ) (m ) 2, (with (TEX-ategory) II 2 Ex d II T4 b II 2 Ex tb III T90 b mbient/ ( ) ircuit /2 NPT *6) 3, , (with II 2 Ex d II T4 b II 2 Ex tb III T90 b /2 NPT *6) 3, *6) able gland not supplied, see table»ccessories«solenoids group 38,5 (m ) (m ) 38, (with (TEX-ategory) mbient/ ( ) Fluid max. +80 ircuit M20 x,5 2, , (with Fluid max. +80 M20 x,5 2, , (with II 2 Ex e mb II T4 b M20 x,5 *6) 3, , (with II 2 Ex e mb II T4 b M20 x,5 *6) 3, version on request pprovals pprovals atasheet TEX IEEx FM 43x, 44x KEM 03 TEX 06 X IEEx EK.0066X N/en x, 68x VS 2 TEX E 068 X N/en xx, 57x EKR VS 08 TEX E 7 N/en en without notice, the specifications given in this document. ( e) 205 Norgren mbh
3 ccessories able gland protection 65 Ms nickel plated brass able gland protection (TEX) Ms nickel plated brass Port size able Ø able Ø M 20x,5 6,5...9,5 mm II2 Ex e mm M 20x,5 9,0...3 mm II2 Ex d mm /2-4-NPT II2 Ex d 7,5...,9 mm Silencer *) Exhaust guard *2) Page 5 M/S4 /2 /S4 /2 NPT Page (/2, /2 NPT) *) For indoors use only *2) For outdoors use, opening pressure ~ 0,2 bar imensions for valves imensions in mm E 3 56 T ø 6,5 ø P N M F 2 K L R S imensions solenoids see page 4 2 For port size, see technical data imensions E F J K L M N Ø P R S T No without notice, the specifications given in this document. ( e) 205 Norgren mbh en
4 imensions for solenoid operators imensions in mm 2 ø ø ,5 50 ø 30,5 78 ø 92 Solenoid 48x Ø 30,5 mm ø 92 ~ M20 x,5 25 ø 30, /2 NPT M ~ ø 38,7 ø 38,7 ircuit s en without notice, the specifications given in this document. ( e) 205 Norgren mbh
5 able gland imensions in mm only ø M20 x, ,5... 9, M20 x,5 6, M20 x, M20 x, /2-4 NPT ,5..., Silencer : M/S2, M/S4, /S2, /S4 Exhaust guard : , ø ø Ø (g) /4 7 35,5 5,5 2,9 M/S2 /4 NPT 7 35,5 5,5 2,9 /S2 / ,5 M/S4 /2 NPT ,5 /S4 Suitable for Ø (g) /4 /4, /4 NPT 0 26, /2 /2, /2 NPT 2 33, Warning These products are intended for use in industrial compressed air systems only. o not use these products where pressures and temperatures can exceed those listed under»technical features/data«. efore using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI NORREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. without notice, the specifications given in this document. ( e) 205 Norgren mbh en
98025 NAMUR/INLINE 3/2 way poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface
9805 NMUR/INLINE / way poppet valves electromagnetic actuated, indirectly controlled G /, / NPT or flanged with NMUR Interface Main application: single operated actuators TÜV-approval based on type examination
More informationOperating pressure (bar) kv factor (m 3 /h) *3)
/ poppet valves (stainless steel) electromagnetic actuated, directly controlled G /8, G /4 or /4 NPT Working from 0 bar up Assembled free of oil and grease Suited for fine vacuum down to,33 0 - mbar For
More informationFlow. group *2) G1/4 1, , B G1/ , B /4 NPT , B N/en
/ poppet valves electromagnetic actuated, directly controlled G /4, G / or /4 NPT Working from 0 bar up Short switching times Suited for fine vacuum down to,33 0 - mbar For a.c. solenoid systems with integrated
More information26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves
60, 8007 NAMUR / & / > > Port size: G/ and NAMUR interface > > Easily interchangeable solenoid system > > For single and double operated actuators > > Standard manual override with detent > > Maintenance-free
More informationV82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability
V8 series - Redundant valve manifold systems - Compact oo Safety, oo Availability and oo Safety and Availability > > Compact design - Herion valves > > Exhaust guards as standard > > SIL certified components
More information2oo2 with bypass valve exhaust guards and indicators. 2oo2 I4. N/en
V8 series Redundant valve manifold systems - Modular with bypass oo Safety, oo Availability and oo Safety and Availability Modular design - Maxseal valves ypass function enables valve removal online Stainless
More information24010, 3/2 Direct solenoid actuated poppet valve
00, / > / (G or NPT) Inline & NAMUR > Main application: Single acting actuators in intrinsically safe circuits > Approval according to IEC 68, multichannel up to SIL > Solenoid valve with low power consumption
More informationMaterial pressure (bar) (Cv (US) kv x 1,2 Seat
00 / way poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 08, DIN V 9 Valves for safety systems up to SIL Solenoid valve
More informationMaterial pressure (bar) (Cv (US) kv x 1,2 Seat. N/en
00 / poppet valves electromagnetic actuated, directly controlled, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 8, DIN V Valves for safety systems up to SIL Solenoid valve also suitable
More information97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface
9700 NAMUR / & / way spool valves electromagnetic actuated, indirectly controlled G /, / NPT, NAMUR Interface For single and double acting actuators / or / way function in one valve Easily interchangeable
More information97105 Inline. Ordering information. Technical data. Accessories See page 5
75 Inline /-, 5/- and 5/ directional valves Actuation: electromagnetic Indirectly controlled soft seal spool valves G /, / NPT, G /, / NPT For single and double operated actuators Crossover-free switching,
More informationBL68 - Olympian Plus plug-in system Filter/regulators and lubricators
> > Port size: 3/4... /2 (ISO G/ PTF) > > Complete air processing units pre-assembled, ready to install Technical features Medium: Compressed air only Maximum operating pressure: 7 bar (246 psi) Pressure
More information97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT
97 Inline /, 5/ & 5/ spool valves electromagnetic actuated, indirectly controlled G /, / NPT For single and double operated actuators Crossover-free switching, switch-over function guaranteed even with
More informationT84T - Excelon Plus Modular System 3/2 shut-off valve
> Port size: 3/8... 3/4 (ISO G/PTF) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > 3/2 way function > Threaded exhaust port > Lockable in closed
More informationICO2S - 2/2, 3/2 or 5/2 Exia poppet valves Electromagnetically actuated, solenoid pilot operated
ICOS - /, / or 5/ Exia poppet valves > > Port size: /... / (ISO G/NPT) /... (Flanged) > > Zone 0, Exia solenoid pilot operated valve > > Safety integrity level and > > Reliable and long life, ideal for
More informationSuper X Inline 3/2 and 5/2 Spool valves, solenoid and pilot actuated
> > Port size: G/8 & G/4 > > Low and high power solenoid coil options > > End, side or face mounting solenoids > > Light weight corrosion resistant materials > > Option for manual override acting directly
More informationFlow direction: Fixed. G1/4, G1/2 NAMUR G1/ Aluminium xxxx***** G1/4, G1/2 NAMUR G1/ Stainless steel xxxx*****
HERION 9805 SERIES Indirect solenoid actuated poppet valves with NMUR interface / - Internal thread G/, / NPT or flanged Main application: single operated actuators TÜV-approval based on IE 6 508,DIN V
More informationWeight (kg) Model L92C- P-ETN. N/en
Excelon Pro Lubricator - Oil Fog ø 6... mm, G /8... G /8 Configuration flexibility Excellent value Low weight No tools required for assembly Technical features Medium: Compressed air Operating pressure:
More information60 series, 2/2 or 3/2 Ball valve
60 series, / or 3/ > > Port size: Rp/8... Rp3, /8... > > Ideally suited for most general purpose applications > > Easy installation, simple operation and maintenance free > > 3-way ball valves with actuator
More informationWeight (kg) Dimension No. G1/4 Exhausting None 0,2 1 T F2BG *1) Interface Exhausting None 0,4 3 T10-N10-D2BN
T > > Port size: / or interface version > > Low operating forces > > High durability > > Easy installation, simple operation and maintenance free > > Full bore passage to maximise flow rate > > Wide pressure
More information82 series Brass compression fittings
> > Port size: Ø 6... 42 mm tube size, SPP and SPT thread > > Suitable for use on seam welded as well as seamless tube or pipe > > For use in areas of vibration > > Pre-assembled units > > No special assembly
More informationHigh pressure valves. 80 to 350 bar
80 to 350 bar High switchable p Hermetically sealed poppet valves Excellent repeatability of switching times Function even with lager voltage tolerance Compact design DN to DN 40 Technical data Medium:
More information26220, 26230, For single- and double-acting drives. Standard manual override with detent. Compact design. Exhaust air silencers.
60, 60, 8007 For single- and double-acting drives /, / and / Directional Control Valves Modular NAMUR design Actuation: Electromagnetic Indirectly controlled spool valves Connections G /8, G /, / NPT Standard
More informationLRA/8000/M/EX, LRA/8000/EX, ISO cylinder Magnetic & Non-magnetic piston, double acting
> > Ø 32... 320 mm > > Comprehensive range for the utmost versatility > > Wide temperature range > > Supplied complete with piston rod locknut > > Conforms to ISO 15552 (ISO 6431, VDM 24562 and NFE 49-003-1)
More informationDrain. Technical data, standard model, shut off valve, filter/regulator with exhaust port and lubricator. Element
BL9 Excelon Pro Combination unit Filter/Regulator and Lubricator ø mm, G / Configuration flexibility Excellent value Low weight No tools required for assembly Technical features Medium: Compressed air
More information3/2 Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface
3/ Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface Suitable for instrumental air, neutral gaseous and liquid fluids and
More informationFor single and double operated actuators. Exhaust air recirculation (3/2 way function)
For single and double operated actuators /-, 5/- and 5/ Directional Control Valves Actuation: Electromagnetic Indirectly controlled soft seal spool valves Connection G /4 or /4 NPT NAMUR interface Exhaust
More information83 series Brass compression fittings
> > Port size: Ø /8... 2, SPP and SPT thread > > For use in areas of vibration > > Pre-assembled units > > No special assembly tools or heat required > > an be remade without damage to tube Technical features
More informationP64F - Olympian Plus plug-in system Soft start/dump valves
> Port size: /4... /4 (ISO G/PTF) > Solenoid, air pilot or manual operator > ssists machine designers in complying with the European Machineries Directive > High forward flow and capacity dump facility
More informationNAMUR FLANGE: With integrated exhaust air recirculation Ordering information
00 TÜV-approval based on IEC 6 08, DIN V 9 Approvals: DIN EN 6/9 DVGW, group Rm and EN 6 Valves for safety systems to SIL or AK 7 / Directional control valves Actuation: electromagnetic Directly controlled
More informationVR61, 3/2, 2 x 3/2, 5/2 or 5/3 Solenoid and pilot actuated spool valves
V6, /, x /, 5/ or 5/ > > ort size: /4 (S /T) > > igh flow rate > > roven sealing system using erion experience in the chemical and process industry > > aintenance-free > > ptional manual overrides > >
More informationDrain. Element. Flow (dm 3 /s) * B92 - K- T1-RMG. N/en
BG, BB Excelon Pro General Purpose filter/regulator ø... mm, G /...G / Configuration flexibility Excellent value Low weight No tools required for assembly Technical features Medium: Compressed air Operating
More informationLPRA/182000/M, ISO cylinder Magnetic piston, double acting
> > Ø 32... 125 mm > > High performance, stability and reliability > > M/50 switches can be mounted flush with the profile > > Cylinders and mountings conform to ISO 15552 (ISO 6431, VDM 24562 and NFE
More informationF84V - Excelon Plus Modular System Oil vapour removal filters
> Port size: 3/8... 3/4 (ISO G/PTF) > Light weight Polycarbonate bowl > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Adsorbing type activated
More informationBL84 - Excelon Plus Modular System Filter/regulator - Lubricator Combination Units
BL84 - Excelon Plus Modular System > Port size: 3/8... 3/4 (ISO G/PTF) > Unique Quikclamp connection system offers full modularity > 40 micron particle and high efficiency water removal (> 98%) > Shut
More informationL84M, L84C - Excelon Plus Modular System Micro- and oilfog lubricator
> Port size: 3/8... 3/4 (ISO G/PTF) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Flow sensor provides a nearly constant oil/air ratio over
More informationF64C, F64H - Olympian Plus Plug-In System Puraire high efficiency coalescing filter
> > Port size: /... 3/ (ISO G/PTF) > > Service indicator standard > > High efficiency coalescing filters > > Quick release bayonet bowl > > Coalescing element removes sub-micron particles and converts
More informationF84G - Excelon Plus Modular System General purpose filter
> Port size: 3/8... 3/4 (ISO G/PTF) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > 5 or 40 micron particle and high efficiency water removal
More informationOur policy is one of continued research and development. We therefore reserve the right
For single and double operated actuators 3/2-, 5/2- and 5/3 Directional Control Valves Actuation: Electromagnetic Indirectly controlled soft seal spool valves Connection G /4, /4 NPT NAMUR Interface Exhaust
More informationFunction. Orifice (mm) NBR (Perbunan) 0 EPDM 1 FKM (Viton) 2 FFKM (Kalrez) / O-ring FKM 4
Working from 0 bar up Short switching times Suited for fine vacuum down to 1,33 10-3 mbar Assembled oil and grease-free For a.c. solenoid systems with integrated rectifier (40 to 60 Hz) These solenoid
More information3 (R) 1 (P) 5 (S) Port size 1 (P) 2 (A) 3 (R) 4 (B) 5 (S)
XSz 8V & XSz 0V 5/ directional control valve with dynamic monitoring For mechanical presses and other safety applications G/4, G/, /4 NPT & / NPT Inherently fail-safe without residual pressure Dynamic
More informationBrass ball valves 60 series
Brass ball valves 60 series /8 to 3 Rp /4 to Rp Ideally suited for most industrial applications Easy installation, simple operation and maintenance free Full bore passage giving minimum flow resistance
More informationVR61 and VR62 3/2, 2 x 3/2, 5/2 and 5/3 directional control solenoid and pilot valves 1/4 or 3/8
V6 and V6 /, x /, 5/ and 5/ directional control solenoid and pilot valves / or /8 igh flow rate roven sealing system using erion experience in the chemical and process industry aintenance-free ptional
More informationVP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control
VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional: serial interface with VP-Tool Software > > Optional
More information97100 NAMUR. Technical data
9700 NAMUR /2-, /2- and / Directional control valves Actuation: electromagnetic Indirectly controlled soft seal spool valves Port size: G /4, /4 NPT NAMUR Interface For single and double operated actuators
More informationF84C - Excelon Plus Modular System Oil removal filter
> Port size: 3/8... 3/4 (ISO G/PTF) > Light weight Polycarbonate bowl > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > High efficiency oil and
More information83 series Brass compression fittings Ø 1/ nominal pipe size, NPT thread
83 series rass compression fittings Ø /8..., NPT thread For use in areas of vibration Pre-assembled units No special assembly tools or heat required an be remade without damage to tube Suitable for use
More informationPRA/842000/M, PRA/ Clean Line cylinder Magnetic or non-magnetic piston, double acting
> > 32... 00 mm > > Cylinder and mounting conform to ISO 5552 > > Smooth and spherical Corrosion resitant design conforms to N 672-2, accepted in the food industry > > Special PU seals provide high performance
More informationLRM/55401/M, Roundline cylinder Magnetic piston, double acting
LRM/5540/M, Roundline cylinder > > 3... 00 mm > > Clean line design > > Low friction, long life seals > > Standard magnetic piston for full control system versatility > > Non-lube operation > > Shock and
More informationT84T - Excelon Plus Modular System 3/2 shut-off valve
> Port size: 3/8" to 3/4" (PTF/ISO G) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > 3/2 way function > Threaded exhaust port > Lockable in
More informationV03, V04, V05 (EXCEL 32) 2/2 & 3/2 Direct solenoid actuated poppet valves
V0, V0, V05 (EXCEL ) / & / > > Port size: G/8, G/ > > Extensive range of power and orifice size options > > Choice of manual override > > Compact installation > > Removeable coil > > Standard exhaust diffuser
More information, /2 Soft start ( soft clutch ) valve
00, 00 / Soft start ( soft clutch ) valve > > Port size: G > > Ideal for soft starting of the pneumatically operated clutch on presses > > eduction wear and tear > > Noise-reduction > > Compact design
More informationNugget 40, V08 series
Nugget 0, V0 series Integrally ported 5/ and 5/3 Spool valves Solenoid actuated and pilot operated Ø, Ø mm or High flow from mm body width Wide range of voltages available Low profile fixed length manifolds
More informationPRA/882000/M/EX, IVAC Clean Line cylinder Magnetic piston, double acting
> ø 3... 100 mm > Complete functional unit with LED display > TEX-zones depending on pilot control: zones &, II 3GD, Valve control module (VCM) zones 1 & 1, II GD, Pilot control on separate specification
More informationNFPA Double acting imperial cylinders
> > Ø 4... 8 > > Adjustable captive cushion needle > > Constructed of the finest materials > > Magnetic piston standard > > Wide temperature range > > Shock and vibration tested to N 61373, Category 1,
More informationA44000, LINTRA-LITE Rodless Cylinders Non-magnetic and Magnetic Piston, double acting
> > Ø 25... 40 mm > > New compact, spacesaving design > > Proven sealing system > > Integral switch mounting > > uffer or adjustable cushioning > > Standard foot mountings Technical features Medium: Compressed
More informationHydraulic pressure switch 20D Acc. to ATEX
Acc. to ATEX 5 to 400 bar For Ex zones 1 and 2 (gases) as well as Ex zones 21 and (dusts) category II2G, type of protection EEx de IIC T6 Microswitch with gold plated contacts Electrical connection: connector
More informationN/** поставка оборудования для подготовки воздуха
M/0000 Series Inline /, 5/ and 5/ Spool Valves Solenoid and Pilot Actuated G / Low power solenoids High flow Unique steel reinforced seals Light weight corrosion resistant materials Technical Data Medium:
More informationVP23 3-way proportional pressure control valve Directly-controlled seat valve with µp-driven pressure control G 1/4... G 3/4
-way proportional pressure control valve Directly-controlled seat valve with µp-driven pressure control G /... G / All-digital control electronics Variable pressure control Optional: serial interface with
More information/2-way piston valves
> > ort size: DN 15... 100, Flange connection, ressure rating N 40 > > djustable: Damped operation () > > Valve operates without differential pressure (Zero delta ) > > Valve piston with TFE guide-ring
More informationPneufit Push-in Tube Fittings Metric
Pneufit Push-in Tube ittings etric 4 14 mm O/ Very compact units asy insertion for rapid assembly of pneumatic circuits Positive anchorage ll P taper threads pre-coated with non-pt based sealant traight
More informationAcoustic Signals Industrial Airhorns > AP Series Product overview
udible Signals INDUSTRIL IRHORNS SOUNDERS coustic Signals Industrial irhorns > Series roduct overview The Series of air horns are suitable for general purpose signalling where high output is required such
More informationV44/V45 series, 2 x 3/2, 5/2 & 5/3 Mini ISO Valves
V/V series, x /, / & / > > x/, / and / valves, ISO 07-/ VDMA 6, Size 6 mm > > Solenoid and pilot actuated > > High performance, compact design > > Flexible sub-base system > > Multipressure system capability
More informationBL84 - Excelon Plus Modular System Filter/regulator - Lubricator Combination Units
BL84 - Excelon Plus Modular System > Port Size 3/8" to 3/4" (PTF/ISO G) > Quickclamp connection system offers full modularity > Shut off valve & Filter/regulator with tamper resistant feature > Metal bowl
More informationVP23. 3-way proportional pressure control valve Directly-controlled seat valve with μp-driven pressure control G 1/4 to G 3/4 Nominal diameter 8/16
VP ll-digital control electronics Variable pressure control, external pressure control upon request Optional: serial interfacing with VP-Tool program Optional actuation via fieldbus (separate data sheet
More informationSeries 20 D. Pressure switches for all-fluid technique Port sizes G 1 /4 and G 1 /2
Series 0 D Pressure switches for all-fluid technique Port sizes and Microswitch with gold-plated contacts (silver plated for outdoor variants) Plug-in connection to DIN 4650 Technical Data Fluid: Neutral
More information2/2-way servo assisted Solenoid Valve
62 2/2-way servo assisted Solenoid Valve Forced coupled diaphragm system ompact body from brass or stainless steel igh flow rate (v value) nti-waterhammer, low noise Type 62 can be combined with... Type
More informationServo-assisted 2/2 way piston valve
Servo-assisted 2/2 way piston valve Type 6240 can be combined with Servo-assisted and compact piston valve with diameter of up to N12 Vibration-resistant, screwed coil system Increased leak-tightness with
More informationAUTO STAR with central connector M12x1
with central connector M2x Non corrosive spool and sleeve for long trouble free life 5/2 and Glandless Valves Actuated Sub-base Mounted ISO 5599- #, #2, #3 6 bar (4,5 W) and 0 bar (2 W) 24V DC solenoids
More informationStrokes (mm) N/en
IVC cleanline Cylinder double acting, magnetic piston 32... 100 mm Cylinders and mountings conform to ISO 15552 Complete functional unit with LED display Central electrical connector, polarity-safe Integrated
More informationNEN Series NFPA Aluminum Cylinders
NEN Series NP luminum ylinders 1-1/2" to 4" bore sizes ompetitively priced Magnetic piston standard djustable cushion standard Sleeve nut construction standard Stocked strokes Technical data Medium: iltered
More information02/97 N/** Our policy is one of continued research and development. We therefore reserve the right to amend,
Nugget 0 V0 Series Integrally Ported 5/2 and 5/3 Spool Valves Solenoid Actuated and Pilot Operated Ø, Ø mm or High flow from mm body width Low power solenoids with a range of voltages Use valves singly
More information2/2 way Coaxial valve CXRM compact, pilot operated Modular design
2/2 way Coaxial valve CXRM compact, pilot operated Modular design Model code (also example order) CXRM 2/2 F C 2 08 040 038 V Standard NC (closed when de-energised) With external 3/2-way pilot valve 4
More informationM/1000, Heavy Duty Cylinders Double Acting
> > Ø 2 to 12 (50 to 305 mm) > > Extremely rugged heavy duty construction - ideal for use in the most arduous conditions. > > Large range of bore sizes - ideal for a wide variety of industrial applications.
More information5/2 and 5/3 Valves Solenoid and Pilot Actuated Sub-base Mounted ISO #1, #2, #3, #4 Steel reinforced main seals
5/2 and 5/3 Valves Solenoid and Pilot Actuated Sub-base Mounted ISO 5599- #, #2, #3, #4 Steel reinforced main seals 6 bar and 0 bar CNOMO solenoid pilots with locking or non-locking manual override Low
More information/2-way piston valves
> > ort size: DN 15... 100 Flange connection, ressure rating N 40 > > Valve operates without differential pressure (Zero delta ) > > Suitable for vacuum > > djustable: Damped operation () > > Valve piston
More informationA robust, pilot operated solenoid valve for direct mounting to pneumatic actuators Figure 79E/79U and PremiAir.
VI F79N Namur Solenoid Valve robust, pilot operated solenoid valve for direct mounting to pneumatic actuators Figure 79E/79 and Premiir. Features ompact design with standardized market proven NMR mounting
More informationRight Angle Control Valve 7051
Right ngle Control Valve 7051 15 up to 50 PN 40 Pneumatically operated valve for control loops with neutral up to highly aggressive media Integrated positioner Compact design ll parts in contact with medium
More informationM/146000/EX, M/146100/EX, M/146200/EX, LINTRA PLUS cylinder Magnetic & Non-magnetic piston, double acting
M/46000/X, M/4600/X, M/4600/X, LINTR PLUS cylinder > Ø 6... 80 mm > New lightweight design extrusion with universal mounting grooves > Proved and patented sealing system > Interchangeability with series
More informationSolenoid valve. Technical data Orifice 1/4 4 Body materials Actuator material Seal material Media Viscosity. Control medium Port connections
/-way Diaphragm Valve with plastic body, pneumatically operated, 1/ 3 with true union 3 with fl ange pplications with aggressive media Flow optimised body with zero dead volume Self draining installation
More informationBürkert Supplement program
ürkert Supplement program Subject to change Design changes can lead to changes in pricing Technical Specifications The technical data in the ordering tables have minimum specifications. or complete information
More informationSOLENOID VALVES no voltage release (lever type) manual reset construction 1/4 to 1/2
SOLENOI VLVES no voltage release (lever type) manual reset construction 1/4 to 1/2 U 1 3 2 3/2 Series 307 FETURES Lever type Manual Reset function which means that the valve has to be energized as well
More informationSBM TECHNOLOGY Cooling / Air Recovery Valve
SBM TECHNOLOGY Cooling / Air Recovery Valve Part no. VSP15203x Advanced high pressure seal technology Integrated non-return valve Robust, compact & lightweight design Proven & reliable technology Maintenance
More informationVM15 series, 2 x 3/2, 5/2 or 5/3 Valve islands
> > Valve slices 2 x 3/2, /2 and /3 with integral push-in fittings Ø 6, 8 and 0 mm > > Multipole or individually wired for installation flexibility > > Quick disconnect base (Pneumapole) > > To configure
More informationAllfluid pressure switches 20D to ATEX
-1... 63 bar For Ex zones 1 and 2 (gases) as well as Ex zones 21 and (dusts) category II2G, type of protection EEx de IIC T6 Microswitch with gold plated contacts Electrical connection: connector M20 x
More informationFluid Control Contents
Fluid Control Contents Solenoid Valves without Differential ressure - Miniature Solenoid Valves Series Material Connection ressure Temperature Function age Chipsol Stainless steel Cartridge 0 to 6 psi
More informationSBM TECHNOLOGY PET Blow Valve Block
Advanced high pressure seal technology Robust, compact & lightweight design Proven & reliable technology Maintenance & service friendly High flow rate exhaust function Minimal dead space volume (< 35ml)
More informationM/48, M/148. 3/2 Poppet Valves Electrically Actuated. Miniature, 22 mm normally closed and normally open models. Sub-base mounted and manifold mounted
M8, M Miniature, 22 mm normally closed and normally open models Sub-base mounted and manifold mounted 32 Poppet Valves Electrically Actuated M5 Manual override as standard Encapsulated coils with very
More informationSOLENOID VALVES direct operated core disc 1/4
SOLENOI VLVES direct operated core disc /4 N U NO / Series 4 FETURES ompact valve intended for single-acting actuator control Epoxy moulded coil for general service applications oils interchangeable without
More informationOur policy is one of continued research and development. We therefore reserve the right
970 Namur /-, /- and /-Directional control valves Electromagnetic indirectly controlled soft seal spool valves G /4, /4 NPT NAMUR-interface For single and double operated actuators Exhaust air recirculation
More information1/96 N Our policy is one of continued research and development. We therefore reserve the right
Roundline Cylinders Magnetic Piston Double cting 8 to 63 mm Very compact and shorter than the basic length of a corresponding ISO/VDM and roundline cylinder. Magnetic piston as standard provides a wide
More informationAppleton s ATX product line includes a wide selection of both Increased Safety and Flameproof cable glands for use with unarmored and armored cable.
ppleton s TX product line includes a wide selection of both Increased Safety and lameproof cable glands for use with unarmored and armored cable. ppleton's TX cable glands are available in a wide range
More informationFor double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring
For double-acting actuators 5/ Directional Control Valves Actuation: Electromagnetic Indirect solenoid operation soft seal spool valve Connections G 1/, 1/ NPT, G 1/, NAMUR Interface Crossover-free switching
More informationC D J K N N/UK /02. Our policy is one of continued research and development. We therefore reserve the right
Manifold system Manifold plate Valve ports V6 V6 V62 Model kg Model kg Model kg 2 2222,23 3 2223,28 4 2224,6 6 2226,86 8 2228, 222,36 2 2222,6 4 2224,86 6 2226 2, 8 2228 2,36 2 2222 2,6 2222,28 2223,45
More informationLAP4, LAP8. Pneumatic linear drive sizes 4 and 8
Pneumatic linear drive sizes 4 and Torsional and bending resistant profiles T-slots in the outer profile enable individual mounting options Adjustable guiding system (LAP4) Precise linear roller guiding
More informationDiscrete direct acting 2 port solenoid valve (general purpose valve) AB31 AB41 Series NC (normally closed) type AB42 Series NO (normally open) type
31414 Series iscrete direct acting port solenoid valve (general purpose valve) 31 41 Series NC (normally closed) type 4 Series NO (normally open) type Port size: Rc1/8 to Rc1/ JIS symbol Common specifications
More informationPRA/822000/M, PRA/ Smoothline cylinder Magnetic or non-magnetic piston, double acting
P/822000/M, P/822000 Smoothline cylinder > 32... 00 mm > Cylinder and mounting conform to ISO 5552 > eed or solid state switches can be mounted flush with the profile barrel > lternative air ports as standard
More informationRM/900/M Heavy duty cylinders Ø 1 1/4... 4
Heavy duty cylinders Ø 1 1/4... 4 Heavy duty cylinder ideal for a wide range of rail applications Extensive range of mountings Rugged, reliable long established design Magnetic piston as standard Mounting
More information2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm
2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm Lockable manual override as standard For liquid, gaseous and aggressive media Long service life, even in non-lube conditions
More informationTechnical Data Sheet
Technical Data Sheet Type 52 2/2-way solenoid valve NC - Valve normally closed (as standard) NO - Valve normally open (as option) Direct operated piston design valve. No differential pressure is necessary
More information