NAMUR FLANGE: With integrated exhaust air recirculation Ordering information
|
|
- Loreen McDowell
- 6 years ago
- Views:
Transcription
1 00 TÜV-approval based on IEC 6 08, DIN V 9 Approvals: DIN EN 6/9 DVGW, group Rm and EN 6 Valves for safety systems to SIL or AK 7 / Directional control valves Actuation: electromagnetic Directly controlled poppet valves Port size: G /, / NPT or Connection hole pattern NAMUR Solenoid valve also suitable for low power consumption in non hazardous areas without barrier Solenoid: Category IIGD, Type of Protection EEx ia IIC T/T6, IP66, T9 C, Suitable for zones, (gases) and, (dusts) Working from 0 bar up High operational reliability even after long periods of inoperation Suitable for control and instrument-quality air Also suitable for open-air installation with appropriate solenoid variant NAMUR FLANGE: With integrated exhaust air recirculation Ordering information See page Technical data Medium: For neutral, not flammable, gaseous and liquid fluids* *With contaminated fluids, upstream installation of a dirt trap is recommended. Operation: Electromagnetic, directly-controlled Flow direction: Optional Mounting position: Any, but preferably with solenoid vertical Connection: G /, / NPT Operating pressure: 0 to 0 bar Ambient temperature: -* to +60 C *Please consult our technical service for use below + C. If installed in the open protect all connections against the penetration of moisture! Materials: Housing: Brass, hard-anodised aluminium Seals: NBR (Perbunan) Internal parts: Stainless steel, brass Solenoid housing: Aluminium, anodized a a b b NAMUR flange /06 Our policy is one of continued research and development. We therefore reserve N/UK..09.0
2 00 General information Switching function: Pressure connection, or Symbol Type Port size Operating *) kv-value Material Weight without Dimensions pressure (bar) (Cv(US) kv x,) Housing Seal solenoid (kg) No. a a b b G / Brass NBR / NPT Brass NBR G / St. st. NBR / NPT St. st. NBR G / NAMUR Aluminium *) NBR / NPT NAMUR Aluminium *) NBR G / NAMUR *) Aluminium *) NBR 0. *) With gaseous and liquid fluids up to 0 mm /s *) Hard-anodised *) P port in flange interface Note: At an ambient temperature of -0 C, higher leakage values may be experienced for short periods. Solenoid parameters for use in intrinsically safe circuits Switch-on max. allowed Holding Holding Pick-up delay typical Categorie, Temperature Type voltage (V) current Ii current voltage (s) type of protection Ambient/Fluid C...8 V 0 ma min 0 ma V 0, - IIG EEx ia IIC T IIG EEx ia IIC T IID IP66 T9 C Solenoid parameters for use in non harardous locations Switch-on max. current Holding Power Pick-up delay typical IP Code Temperature Type voltage (V) (limited) current consumption (s) Ambient/Fluid (switching C and holding)...6, V 7 ma min 0 ma,8 W at V 0, - s IP Accessories Flange plate Yoke Silencer (NAMUR single connection plate) 009 C/S, / NPT 0679 (NAMUR-rip use in combination with 06790, Alu) M/S, G / Ordering information / directional control valve, connection G /, housing brass, with protection class EEx ia IIC T6 Type: N/UK Our policy is one of continued research and development. We therefore reserve /06
3 00 Operating sequence 8 V V Supply 0 V Charging voltage prozess V Current process Valve, operating status ma Switching delay Current supply units: Intrinsically safe power supply units can be choosen in a list of compatibility in When selecting an intrinsically safe power supply, it is important to observe the maximum permissible values acc. to the EC-Type-Examination Certificate PTB 0 ATEX 00 U0 8 V, L0 0 ma, P0, W The effective internal capacities Ci; and inductivities Li of the solenoid are negligibly low. Function of solenoid drive To switch the direct operated valve, a certain energy is required. This energy is stored in a condenser. The charging voltage is V. The higher the supply voltage, the shorter the charging time. As soon as the charging voltage has been reached, the valve switches. The small current now flowing through the coil is sufficient to hold the valve in the open position. At least 0 ma are required for this. /06 Our policy is one of continued research and development. We therefore reserve N/UK..09.0
4 00 Dimensions ➀ 70, M0 x, For port size see general information deep ➁ 9 70, 0 0 7, M,, 7, G / 6, 9 G / ø, ø 9, G / 9, 6,, 6, ➂ 9 70, 0 0 6, 7, M ø0 M6,, 7, ø, G / ø 9,, G / 9, 6,, 6, N/UK Our policy is one of continued research and development. We therefore reserve /06
5 00 Filter cartridge (for threads G / and / NPT) Type: 0687 Circuit diagram, 8, 60 Ø 0, Thread pitch diameter max.,8 mm 60 NAMUR hole pattern M Port (A) Coding stud threaded M (0 deep) Port (R) Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under Technical Data. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. /06 Our policy is one of continued research and development. We therefore reserve N/UK..09.0
Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en
00 / poppet valves electromagnetic actuated, directly controlled, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 8, DIN V Valves for safety systems up to SIL Solenoid valve also suitable
More informationMaterial pressure (bar) (Cv (US) kv x 1,2 Seat
00 / way poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 08, DIN V 9 Valves for safety systems up to SIL Solenoid valve
More information24010, 3/2 Direct solenoid actuated poppet valve
00, / > / (G or NPT) Inline & NAMUR > Main application: Single acting actuators in intrinsically safe circuits > Approval according to IEC 68, multichannel up to SIL > Solenoid valve with low power consumption
More information97100 NAMUR. Technical data
9700 NAMUR /2-, /2- and / Directional control valves Actuation: electromagnetic Indirectly controlled soft seal spool valves Port size: G /4, /4 NPT NAMUR Interface For single and double operated actuators
More informationV82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability
V8 series - Redundant valve manifold systems - Compact oo Safety, oo Availability and oo Safety and Availability > > Compact design - Herion valves > > Exhaust guards as standard > > SIL certified components
More informationHigh pressure valves. 80 to 350 bar
80 to 350 bar High switchable p Hermetically sealed poppet valves Excellent repeatability of switching times Function even with lager voltage tolerance Compact design DN to DN 40 Technical data Medium:
More information97105 Inline. Ordering information. Technical data. Accessories See page 5
75 Inline /-, 5/- and 5/ directional valves Actuation: electromagnetic Indirectly controlled soft seal spool valves G /, / NPT, G /, / NPT For single and double operated actuators Crossover-free switching,
More informationHERION SERIES Indirect solenoid actuated soft seal
HERION 9700 SERIES Indirect solenoid actuated soft seal spool valves with NAMUR interface /, 5/ - G/ For single and double acting actuators Crossover-free switching, switchover function guaranteed even
More informationFor single and double operated actuators. Exhaust air recirculation (3/2 way function)
For single and double operated actuators /-, 5/- and 5/ Directional Control Valves Actuation: Electromagnetic Indirectly controlled soft seal spool valves Connection G /4 or /4 NPT NAMUR interface Exhaust
More information3/2 Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface
3/ Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface Suitable for instrumental air, neutral gaseous and liquid fluids and
More informationOur policy is one of continued research and development. We therefore reserve the right
For single and double operated actuators 3/2-, 5/2- and 5/3 Directional Control Valves Actuation: Electromagnetic Indirectly controlled soft seal spool valves Connection G /4, /4 NPT NAMUR Interface Exhaust
More information97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface
9700 NAMUR / & / way spool valves electromagnetic actuated, indirectly controlled G /, / NPT, NAMUR Interface For single and double acting actuators / or / way function in one valve Easily interchangeable
More informationOur policy is one of continued research and development. We therefore reserve the right
970 Namur /-, /- and /-Directional control valves Electromagnetic indirectly controlled soft seal spool valves G /4, /4 NPT NAMUR-interface For single and double operated actuators Exhaust air recirculation
More information98025 NAMUR/INLINE 3/2 way poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface
9805 NMUR/INLINE / way poppet valves electromagnetic actuated, indirectly controlled G /, / NPT or flanged with NMUR Interface Main application: single operated actuators TÜV-approval based on type examination
More informationFlow. group *2) G1/4 1, , B G1/ , B /4 NPT , B N/en
/ poppet valves electromagnetic actuated, directly controlled G /4, G / or /4 NPT Working from 0 bar up Short switching times Suited for fine vacuum down to,33 0 - mbar For a.c. solenoid systems with integrated
More information26220, 26230, For single- and double-acting drives. Standard manual override with detent. Compact design. Exhaust air silencers.
60, 60, 8007 For single- and double-acting drives /, / and / Directional Control Valves Modular NAMUR design Actuation: Electromagnetic Indirectly controlled spool valves Connections G /8, G /, / NPT Standard
More information97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT
97 Inline /, 5/ & 5/ spool valves electromagnetic actuated, indirectly controlled G /, / NPT For single and double operated actuators Crossover-free switching, switch-over function guaranteed even with
More informationOperating pressure (bar) kv factor (m 3 /h) *3)
/ poppet valves (stainless steel) electromagnetic actuated, directly controlled G /8, G /4 or /4 NPT Working from 0 bar up Assembled free of oil and grease Suited for fine vacuum down to,33 0 - mbar For
More information26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves
60, 8007 NAMUR / & / > > Port size: G/ and NAMUR interface > > Easily interchangeable solenoid system > > For single and double operated actuators > > Standard manual override with detent > > Maintenance-free
More informationFor double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring
For double-acting actuators 5/ Directional Control Valves Actuation: Electromagnetic Indirect solenoid operation soft seal spool valve Connections G 1/, 1/ NPT, G 1/, NAMUR Interface Crossover-free switching
More informationFlow direction: Fixed. G1/4, G1/2 NAMUR G1/ Aluminium xxxx***** G1/4, G1/2 NAMUR G1/ Stainless steel xxxx*****
HERION 9805 SERIES Indirect solenoid actuated poppet valves with NMUR interface / - Internal thread G/, / NPT or flanged Main application: single operated actuators TÜV-approval based on IE 6 508,DIN V
More informationHydraulic pressure switch 20D Acc. to ATEX
Acc. to ATEX 5 to 400 bar For Ex zones 1 and 2 (gases) as well as Ex zones 21 and (dusts) category II2G, type of protection EEx de IIC T6 Microswitch with gold plated contacts Electrical connection: connector
More informationFunction. Orifice (mm) NBR (Perbunan) 0 EPDM 1 FKM (Viton) 2 FFKM (Kalrez) / O-ring FKM 4
Working from 0 bar up Short switching times Suited for fine vacuum down to 1,33 10-3 mbar Assembled oil and grease-free For a.c. solenoid systems with integrated rectifier (40 to 60 Hz) These solenoid
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
/-, 5/- 5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx
More informationType 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics Type 658 standard standard High flow-rate capacity Reduced power consumption Single or manifold mounting Standard-, EEx m and EEx i versions
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
/2-, 5/2-5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx
More informationAllfluid pressure switches 20D to ATEX
-1... 63 bar For Ex zones 1 and 2 (gases) as well as Ex zones 21 and (dusts) category II2G, type of protection EEx de IIC T6 Microswitch with gold plated contacts Electrical connection: connector M20 x
More information2oo2 with bypass valve exhaust guards and indicators. 2oo2 I4. N/en
V8 series Redundant valve manifold systems - Modular with bypass oo Safety, oo Availability and oo Safety and Availability Modular design - Maxseal valves ypass function enables valve removal online Stainless
More informationSpecial valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.
Special valves Operation Series Page no. Function 2/2 Body material Brass Aluminium Solenoids IP Protection class Explosion proof class IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64 EEx
More informationICO2S - 2/2, 3/2 or 5/2 Exia poppet valves Electromagnetically actuated, solenoid pilot operated
ICOS - /, / or 5/ Exia poppet valves > > Port size: /... / (ISO G/NPT) /... (Flanged) > > Zone 0, Exia solenoid pilot operated valve > > Safety integrity level and > > Reliable and long life, ideal for
More information3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
More informationThe extendable type 5470 EExi can be used for block modules or for entire valve blocks (tag connectors on top, coil spacing 19 mm).
/2- and 4/2-multi-way valves ; servo-assisted; block assembly or NAMUR flange; DN 4; flow rate: 00 l/min Advantages / Benefits II 2G EEx ia IIC T6 PTB0 ATEX 275 approved Available for block assembly and
More informationSolenoid Valves Type 3963
Mounting and Operating Instructions Solenoid Valves Type 3963 Fig. 1 General Assembly, commissioning and operation of these devices may only be performed by experienced personnel. Proper shipping and appropriate
More informationT 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators
T 365 EN Type 365 Solenoid Valve Island To control pneumatic actuators Application The Type 365 Solenoid Valve Island is a compact solution for the central control of pneumatic actuators in chemical and
More information2/2 Pressure operated valves
Operation Series Page no. Function 2/2 3/2 Body material Stainless steel Brass Solenoids IP Protection class IP65 (with connector) Explosion proof class Zones 1, 21 II 2 GD EEx m IP67 II 2 G EEx me IP54
More informationVersions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve
Type 367 Solenoid Valve Application Solenoid valve for controlling pneumatic linear actuators with NAMUR rib according to IEC 60534 or pneumatic rotary actuators with NAMUR interface according to VDI/VDE
More information18D according to ATEX
Pneumatic ressure switch -... bar Hydraulic ressure switch 5... 4 bar For EX-alications according to ATEX 00 a: Zone 2 category ATEX 3G (gases) Zone 22 category ATEX 3D (dust) TÜV (technical insection
More information-V- New. Valve series VOFC. 2009/08 Subject to change Internet:
Valve series VOFC 2009/08 Subject to change Internet: www.festo.com/catalogue/... 159 Solenoid valves VOFC Key features General information The valves in the VOFC series are special 3/2-way and 5/2-way
More informationSuper X Inline 3/2 and 5/2 Spool valves, solenoid and pilot actuated
> > Port size: G/8 & G/4 > > Low and high power solenoid coil options > > End, side or face mounting solenoids > > Light weight corrosion resistant materials > > Option for manual override acting directly
More information25000, 4/2 Direct solenoid actuated poppet valves
> > Port size: /4, /2 > > Working from 0 bar up > > Suited for outdoor installation > > Suitable for vacuum range down.33 0-2 mbar l/s > > : 65, Ex em, Ex d TEX approved (see solenoid table) Technical
More informationKämmer Actuators Series 4 Pneumatic and Electropneumatic
flowserve.com Kämmer Pneumatic and Electropneumatic Description Kämmer pneumatic actuators are widely known for their versatile diaphragm design, easy installation and simplified maintenance. When compared
More information5/2 and 5/3 Valves Solenoid and Pilot Actuated Sub-base Mounted ISO #1, #2, #3, #4 Steel reinforced main seals
5/2 and 5/3 Valves Solenoid and Pilot Actuated Sub-base Mounted ISO 5599- #, #2, #3, #4 Steel reinforced main seals 6 bar and 0 bar CNOMO solenoid pilots with locking or non-locking manual override Low
More informationSeries 20 D. Pressure switches for all-fluid technique Port sizes G 1 /4 and G 1 /2
Series 0 D Pressure switches for all-fluid technique Port sizes and Microswitch with gold-plated contacts (silver plated for outdoor variants) Plug-in connection to DIN 4650 Technical Data Fluid: Neutral
More informationLimit Switch Type 4747
Limit Switch Type 4747 Ex d flameproof enclosure with inductive or mechanical contacts for linear actuators or rotary actuators acc. to VDI/VDE 3845 General The Type 4747 Limit Switch issues an electrical
More informationPilot operated solenoid valves for pneumatic actuators
Pilot solenoid valves for pneumatic actuators 3 / 2 and 5 / 2 way solenoid valves Orifice size 6 and 12 mm NAMUR and threaded connections Pressure range 0 (2) 8 bar For air and inert gases With TÜV-approval
More informationDirect-acting 3/2 way plunger valve
Direct-acting 3/2 way plunger valve Direct-acting, compact valve with diameter of up to DN 2.5 Vibration-proof, bolted coil system Banjo threaded connection for direct mounting on pneumatic valves Type
More informationElectro-pneumatic control valves
Electropneumatic control valves Visit our website for further information www.crouzet.com 9 Electropneumatic miniature solenoid Miniature solenoid valves Terminals Wires Connector LED indicators Valve
More informationEngineering GREAT Solutions
Engineering GREAT Solutions Process Express Precision. Engineered. Through our people, products and service. Contents 1 2 3 4 5 6 VALVES I/P & E/P CONVERTERS PRESSURE SWITCHES & SENSORS AIR PREPARATION
More informationLAP4, LAP8. Pneumatic linear drive sizes 4 and 8
Pneumatic linear drive sizes 4 and Torsional and bending resistant profiles T-slots in the outer profile enable individual mounting options Adjustable guiding system (LAP4) Precise linear roller guiding
More informationPHOENIX CONTACT - 01/2008
Exi Solenoid Driver, With Intrinsically Safe Output, LoopPowered, TwoChannel INTERFACE Data Sheet 0289_00_en PHOENIX CONTACT 0/2008 Description The PIEXME2SD/24/65C is a twochannel solenoid driver. It
More informationSolenoid Valve Island Type 3965
Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and
More informationSeries 3730 Electropneumatic Positioner Type
Series 3730 Electropneumatic Positioner Type 3730-1 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and
More information3 (R) 1 (P) 5 (S) Port size 1 (P) 2 (A) 3 (R) 4 (B) 5 (S)
XSz 8V & XSz 0V 5/ directional control valve with dynamic monitoring For mechanical presses and other safety applications G/4, G/, /4 NPT & / NPT Inherently fail-safe without residual pressure Dynamic
More informationSBM TECHNOLOGY Cooling / Air Recovery Valve
SBM TECHNOLOGY Cooling / Air Recovery Valve Part no. VSP15203x Advanced high pressure seal technology Integrated non-return valve Robust, compact & lightweight design Proven & reliable technology Maintenance
More information/2-way piston valves
> > ort size: DN 15... 100, Flange connection, ressure rating N 40 > > djustable: Damped operation () > > Valve operates without differential pressure (Zero delta ) > > Valve piston with TFE guide-ring
More informationC D J K N N/UK /02. Our policy is one of continued research and development. We therefore reserve the right
Manifold system Manifold plate Valve ports V6 V6 V62 Model kg Model kg Model kg 2 2222,23 3 2223,28 4 2224,6 6 2226,86 8 2228, 222,36 2 2222,6 4 2224,86 6 2226 2, 8 2228 2,36 2 2222 2,6 2222,28 2223,45
More informationSPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function)
SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, NAMUR, / 0 0 /-/ Série FEATURES The monostable spool valves have TÜV certified IEC 608 Functional
More informationMFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS
Solenoid coils Solenoid coils Product range overview Version Type For valve series Page/ Internet MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS F solenoid coil MSF VACF 3 N solenoid coil VACN-N 6 N
More informationN/** поставка оборудования для подготовки воздуха
M/0000 Series Inline /, 5/ and 5/ Spool Valves Solenoid and Pilot Actuated G / Low power solenoids High flow Unique steel reinforced seals Light weight corrosion resistant materials Technical Data Medium:
More informationBody: Seat disc: Anod. aluminium body NBR. Connection / Orifice Flow factors Temperature values ( C)
Parker Lucifer Data Sheet 22062004 General information Lucifer ref.: 341N31 Global ref.: 7341NAKBJNM0 Housing ref.: 2995 Coil ref.: 481865 Protection class: Assembly wt. (g): 510 Body: Seat disc: Anod.
More informationType Electronic Limit Switch
Type 3738-20 Electronic Limit Switch With optional solenoid valve Application Electronic limit switch for on/off applications to indicate the end position. Optionally with integrated solenoid valve. Special
More information3/2 Way Pilot Valve 3/2 Way Solenoid Valve 1 /4" and 1 /2" 5/2 Way Solenoid Valve 1 /4" 6/2 Way Solenoid Valve 1 /4" 5/3 Way Solenoid Valve 1 /4"
/2 Way Pilot Valve /2 Way Solenoid Valve 1 /" and 1 /2" 5/2 Way Solenoid Valve 1 /" 6/2 Way Solenoid Valve 1 /" 5/ Way Solenoid Valve 1 /" General The solenoid valves consist of one or two /2 way pilot
More informationSPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot
SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter
More informationINLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1
INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn
More informationSKINNER Intrinsically Safe Series Four-Way
SKINNER Four-Way Two-Position Valves SPECIFICATIONS Mechanical Characteristics Standard Materials of Body Aluminum Seals FKM, NBR. Other diaphragm materials available upon request. Compatible Fluids Air
More informationSPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4
SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, /4 4 2 5 4 2 5 4 2 5 4 2 5 5/2 Series 55 FEATURES The monostable spool valves have TÜV certified
More information/2-way piston valves
> > ort size: DN 15... 100 Flange connection, ressure rating N 40 > > Valve operates without differential pressure (Zero delta ) > > Suitable for vacuum > > djustable: Damped operation () > > Valve piston
More information3/2-way Rocker Solenoid Valve for pneumatic systems
3/-way Rocker Solenoid Valve for pneumatic systems EEx ia versions Direct-acting High cycling rate Reduced power consumption Type 6104 can be combined with... Sub-base connection Approvals: Type 654 Servo-assisted
More informationSPOOL VALVES pilot operated or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4
SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid (mono/bistable function) brass body, /4 NC 0 0 / Series 55 FEATURES The monostable spool valves have TÜV certified IEC 6508
More informationElectronic Limit Switch Type
Electronic Limit Switch Type 3738-20 with optional solenoid valve for on/off rotary actuators Application Electronic limit switch for on/off applications to indicate the end position of rotary actuators.
More information2/2-way Globe Valve for media up to +180 C, DN
2/2-way Globe Valve for media up to +180 C, DN 10-100 Compact globe valve version Flange, threaded and welded ports as standard Stainless steel 316L valve body Available with flow direction below and above
More informationPneumatic Positioner Type 3766 Electropneumatic Positioner Type 3767
Pneumatic Positioner Type 3766 Electropneumatic Positioner Type 3767 Application Single-acting or double-acting positioners for attachment to pneumatic control valves. Supplied with a pneumatic input signal
More informationNugget 40, V08 series
Nugget 0, V0 series Integrally ported 5/ and 5/3 Spool valves Solenoid actuated and pilot operated Ø, Ø mm or High flow from mm body width Wide range of voltages available Low profile fixed length manifolds
More informationPorts. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:
Solenoid operated EEx d IIC T6 Description of the Valve Directional control valves direct the flow in various directions (P A with 2/2 valves and P A // A T) with 3/2 valves. Available as 2/2 and 3/2 valves,
More information7/S1 FIRE DAMPER PPZEN. v 2.5 (en)
7/S1 v.5 (en) FIRE DAMPER PPZEN www.klimaoprema.hr 39 TABLE OF CONTENTS Product description... Range... Fire classification according to EN 13501-3... Operating mechanisms and dimensions... Operating manual...
More informationApplication The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.
DA03 Differential Pressure Gauge / Differential Pressure Gauge and Switch Models for Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Application The DA03 serves as indicator of differential
More informationAUTO STAR with central connector M12x1
with central connector M2x Non corrosive spool and sleeve for long trouble free life 5/2 and Glandless Valves Actuated Sub-base Mounted ISO 5599- #, #2, #3 6 bar (4,5 W) and 0 bar (2 W) 24V DC solenoids
More informationV03, V04, V05 (EXCEL 32) 2/2 & 3/2 Direct solenoid actuated poppet valves
V0, V0, V05 (EXCEL ) / & / > > Port size: G/8, G/ > > Extensive range of power and orifice size options > > Choice of manual override > > Compact installation > > Removeable coil > > Standard exhaust diffuser
More informationCommon wiring modules can be connected by fieldbus, multi-pole or common earth/neutral modules.
/ and 4/ multi-way valves; servo assisted; DN 4; flow rate: l/min.; /8, legris ø 6 mm port connections Advantages / Benefits Optimised system solutions due to high level of modularity Compact design with
More informationPositioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories. Selection and Application
Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories Selection and Application Associated s T 8355 EN ff. Edition January 2010 Information Sheet T 8350 EN Positioners,
More informationMulti Way Valves for Pneumatics Servo Assisted, Extendable, 10mm Wide
Multi Way Valves for Pneumatics Servo Assisted, Extendable, 10mm Wide 3/2 and 5/2 Way Valves Optimum system solutions due to high level of modularity Maintenance free and little wear due to high level
More informationSBM TECHNOLOGY PET Blow Valve Block
Advanced high pressure seal technology Robust, compact & lightweight design Proven & reliable technology Maintenance & service friendly High flow rate exhaust function Minimal dead space volume (< 35ml)
More information% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT
4 Air and Inert Gas Intrinsically Safe Valves Brass, Aluminum, or Stainless Steel Bodies /4" to " NPT / 3/ 4/ 5/ 5/3 Features Intrinsically safe solenoid enclosures to provide corrosion resistance in harsh
More informationM/48, M/148. 3/2 Poppet Valves Electrically Actuated. Miniature, 22 mm normally closed and normally open models. Sub-base mounted and manifold mounted
M8, M Miniature, 22 mm normally closed and normally open models Sub-base mounted and manifold mounted 32 Poppet Valves Electrically Actuated M5 Manual override as standard Encapsulated coils with very
More informationSentronic PLUS 614 Series
Sentronic PLUS 64 Series Proportional Technology www.asco.com PRESSURE CONTROL: 64 SERIES SENTRONIC PLUS Sentronic PLUS Sentronic PLUS is a digitally operated pressure regulator valve. This valve accurately
More informationOffshore and Onshore Applications Lucifer TM 2/2 and 3/2 ways 316L Stainless Steel solenoid valves
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding courtesy of Statoil Offshore and Onshore Applications Lucifer TM 2/2
More informationSensor boxes SRBE Key features and product range overview
Sensor boxes SRBE Sensor boxes SRBE Key features and product range overview Function Sensor boxes SRBE are used for electrical feedback and control of the position of process valves actuated using pneumatic
More informationXMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.
Process Pressure Transmitter with HART -communication Ceramic Sensor accuracy according to IEC 60770: 0.1 % FSO Nominal pressure from 0... 160 mbar up to 0... 20 bar Output signals 2-wire:... 20 ma others
More informationField IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage
Data Sheet Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage Reliable through well-proven concept - More than 1,000,000 units in use
More informationTechnical Data Sheet
Technical Data Sheet Type 52 2/2-way solenoid valve NC - Valve normally closed (as standard) NO - Valve normally open (as option) Direct operated piston design valve. No differential pressure is necessary
More informationResistance thermometer Model TR10-E, for additional thermowell
Electrical temperature measurement Resistance thermometer Model TR10-E, for additional thermowell WIKA data sheet TE 60.05 further approvals see page 6 Applications Chemical industry Petrochemical industry
More informationActuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage
Data Sheet Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage Reliable through well-proven concept - More than 1,000,000 units in use Compact
More informationLimit switch attachments DAPZ
Type codes DAPZ SB M 250AC DR AR Type DAPZ Limit switch attachment Specification SB Sensor box Measuring principle I M Inductive Electrical, micro switch Operating voltage 25DC 30DC 250AC 8 V DC 30 V DC
More informationValve series KN-05 acc. to NAMUR, 3/2-way G1/4 780 Nl/min (0.792 Cv)
Valve series KN-05 acc. to NAMUR, 3/2-way G1/4 780 Nl/min (0.792 Cv) Order code Series and function 1) Plug socket see page 5.042. KN-05-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More informationMN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142
Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series Order code -310-HN-142 Series and function Standard coil 1) (with plug socket 28-ST-01) 141 = 12 V DC, 4.2
More informationValve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More informationT84T - Excelon Plus Modular System 3/2 shut-off valve
> Port size: 3/8... 3/4 (ISO G/PTF) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > 3/2 way function > Threaded exhaust port > Lockable in closed
More informationPneumatic control unit for decentralized automation of ELEMENT process valves
890 Pneumatic control unit for decentralized automation of ELEMENT process valves Type 890 can be combined with... Compact design Integrated pilot valve with manual override Integrated control air routing
More informationDirect-acting 2/2-way plunger valve
Direct-acting 2/2-way plunger valve Type can be combined with Direct-acting and compact valve up to diameter of DN 6.0 Vibration-proof, bolted coil system Increased leak-tightness with welded plunger guiding
More informationExplosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo
Explosion-proof Solenoids II 2 G / II 2 D EEx dm IIC T4, T5, T6 Catalogue Maximum photo ATEX Explosionproof solenoids with flameproof enclosure/encapsulation "dm" According to ATEX directive 94/9/EC and
More information